GENERAL PROJECT NOTES
PROJECT DATA
1. THE CONTRACT DOCUMENTS ARE THE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF THE DESIGNER WHETHER THE PROJECT FOR WHICH THEY ARE PREPARED IS EXECUTED OR NOT.
PROJECT DESCRIPTION:
2. “INSTALL” MEANS SUPPLIED BY OTHERS, TO BE INSTALLED BY CONTRACTOR.
THIS PROJECT IS A PARTIAL RENOVATION TO THE SECOND FLOOR AT THE NORTH SIDE OF BURRUSS HALL. THERE IS NO CHANGE OF USE, INCREASE IN AREA, OR ACTIVITY FUNCTIONS. APPLICABLE CODES AND REFERENCE STANDARDS:
3. “PROVIDE” MEANS FURNISH AND INSTALL, COMPLETE AND IN PLACE. INTERNATIONAL BUILDING CODE (IBC 2012 EDITION) NATIONAL ELECTRIC CODE (NEC) AMERICANS WITH DISABILITIES ACT (ADA)
4. “TYPICAL” MEANS IDENTICAL FOR CONDITIONS NOTED. 5. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. VERIFY DIMENSIONS WITH FIELD CONDITIONS, IF DISCREPANCIES ARE DISCOVERED BETWEEN FIELD CONDITIONS AND DRAWINGS OR BETWEEN INDIVIDUAL DRAWINGS, CONTACT THE DESIGNER FOR RESOLUTION BEFORE PROCEEDING.
USE GROUP CLASSIFICATION (EXISTING SPACE): E (EDUCATION) A (ASSEMBLY)
6. HORIZONTAL DIMENSIONS INDICATED ARE TO/FROM FINISHED FACE OF CONSTRUCTION, EXCEPT WHEN NOTED AS CENTERLINE (CL), DIMENSIONS ARE TO CENTERLINE OF FRAMING.
USE GROUP CLASSIFICATION (PROPOSED SPACE): A (ASSEMBLY) * NOTE: THERE IS NO CHANGE OF USE.
7. VERTICAL DIMENSIONS ARE FROM TOP OF FLOOR SLAB, EXCEPT WHERE NOTED TO BE FROM ABOVE FINISHED FLOOR, (A.F.F.).
CONSTRUCTION TYPE: 2A NON-COMBUSTIBLE, PROTECTED
8. CUT AND FIT COMPONENTS FOR ALTERATION OF EXISTING WORK AND INSTALLATION OF NEW WORK. PATCH DISTURBED AREAS TO MATCH ADJACENT MATERIALS AND FINISHES.
OCCUPANT LOADS: EDUCATION AREAS CALCULATED AT 20 ASSEMBLY AREAS CALCULATED AT 15
SQ.FT. PER OCCUPANT SQ.FT. PER OCCUPANT
9. PATCH AND REPAIR ALL FIREPROOFING DAMAGED OR REMOVED DURING PERFORMANCE OF THE WORK. FIREPROOF NEW PENETRATIONS REQUIRED BY THE WORK AND EXISTING PENETRATIONS IN EXPOSED PLENUM AREAS.
OCCUPANT LOAD: PROPOSED SPACE, SECOND FLOOR:
CODE: 482 ACTUAL: 130
PROJECT SQUARE FOOTAGE: PROPOSED SPACE, SECOND FLOOR:
9,550 NET SQ.FT.
10. CONTRACTOR & SUB-CONTRACTORS SHALL COORDINATE THE LAYOUT AND EXACT LOCATIONS OF ALL PARTITIONS, DOORS, ELECTRICAL/TELEPHONE OUTLETS AND LIGHT SWITCHES WITH DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION.
VIRGINIA TECH SCHOOL OF ARCHITECTURE + DESIGN 222 Burruss Hall, Blacksburg, VA 24060
NO.
DESCRIPTION
DATA
11. CONTRACTOR SHALL PROVIDE MANUFACTURER’S SPECIFICATIONS, INSTALLATION INSTRUCTIONS, SHOP DRAWINGS AND SAMPLES FOR REVIEW AND APPROVAL OF ALL MATERIALS AND METHODS TO BE USED PRIOR TO ORDERING OR PROCEEDING WITH THE WORK. 12. CONTRACTOR TO FOLLOW MANUFACTURER’S RECOMMENDED SPECIFICATIONS AND INSTALLATION PROCEDURES. IF THESE ARE CONTRARY TO THE CONTRACT DOCUMENTS, CONTRACTOR SHALL NOTIFY THE DESIGNER, IN WRITING IMMEDIATELY, TO RESOLVE DISCREPANCIES PRIOR TO PROCEEDING. 13. CONTRACTOR SHALL ORDER AND SCHEDULE DELIVERY OF MATERIALS IN AMPLE TIME TO AVOID DELAYS IN CONSTRUCTION. IF AN ITEM IS FOUND TO BE UNAVAILABLE, CONTRACTOR SHALL NOTIFY DESIGNER IMMEDIATELY TO ALLOW DESIGNER A REASONABLE AMOUNT OF TIME TO SELECT A REASONABLE SUBSTITUTE. 14. THE FINISHED WORK SHALL BE FIRM, WELL ANCHORED, IN TRUE ALIGNMENT, PLUMB, LEVEL, WITH SMOOTH, CLEAN, UNIFORM APPEARANCE WITHOUT WAVES, DISTORTIONS, HOLES, MARKS, CRACKS, STAINS, OR DISCOLORATION. JOINTING SHALL BE TIGHT FITTING, NEAT AND WELL SCRIBED. THE FINISH WORK SHALL NOT HAVE EXPOSED UNSIGHTLY ANCHORS OR FASTENERS AND SHALL NOT PRESENT HAZARDOUS, UNSAFE CORNERS. ALL WORK SHALL HAVE THE PROVISION FOR EXPANSION CONTRACTION, AND SHRINKAGE AS NECESSARY TO PREVENT CRACKS, BUCKLING AND WARPING DUE TO TEMPERATURE AND HUMIDITY CONDITIONS. 15. CONTRACTOR SHALL COMPLY WITH ALL BASE BUILDING REQUIREMENTS AND DESIGN CRITERIA. 16. ALL WORK SHALL COMPLY WITH THE APPLICABLE CODES, AMENDMENTS, RULES, REGULATIONS, ORDINANCES, LAWS, ORDERS, APPROVALS, ETC., THAT ARE REQUIRED BY PUBLIC AUTHORITIES. IN THE EVENT OF CONFLICT, THE MOST STRINGENT REQUIREMENTS SHALL COMPLY. REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED TO THE CURRENT APPLICABLE EDITIONS OR PUBLICATIONS OF THE FOLLOWING (OR OTHERWISE NOTED): A. INTERNATIONAL BUILDING CODE (IBC 2012 EDITION) B. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) C. NATIONAL ELECTRIC CODE (NEC) D. INTERNATIONAL PLUMBING CODE (IPC 2009 EDITION) E. INTERNATIONAL MECHANICAL CODE (IMC 2009 EDITION) F. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) G. AMERICANS WITH DISABILITIES ACT (ADA) H. LOCAL MUNICIPAL ORDINANCES AND AMENDMENTS TO THE CODES
SHEET INDEX SHEET # A100 A102 A103 A101 A104 A105 A106 A107 A108 A109 A110 A111 A112 A113 A114 A115 A116
SHEET NAME COVER SHEET EXISTING PLAN DEMOLITION PLAN FIRE + SAFETY PLAN PLAN ENLARGED PLAN INTERIOR SECTIONS WALL SECTIONS INTERIOR ELEVATIONS INTERIOR WALL DETAILS MILLWORK DETAILS FINISH PLAN FURNITURE PLAN POWER + DATA PLAN RCP ENLARGED RCP PHASING
CONSULTANT ADDRESS ADDRESS PHONE FAX E-MAIL CONSULTANT ADDRESS ADDRESS PHONE FAX E-MAIL CONSULTANT ADDRESS ADDRESS PHONE FAX E-MAIL CONSULTANT ADDRESS ADDRESS PHONE FAX E-MAIL
CONSULTANT ADDRESS ADDRESS PHONE FAX E-MAIL
PROJECT NUMBER DATE DRAWN BY CHECKED BY TRUE NORTH
PROJECT NORTH
AREA OF NEW CONSTRUCTION BURRUSS HALL, ROOM 224A
SITE MAP
BURRUSS HALL, ROOM 224A
VACINITY MAP
VIRGINIA TECH, BLACKSBURG, VIRGINIA
COVER SHEET
PROJECT NORTH
A100
2017_0001 02 MAY 2017 J. BEAN M. WAGNER