Food Feed Beverage Analysis Solutions (AU) - John Morris Group

Page 1

Food/Feed & Beverage Analysis Solutions

www.johnmorrisgroup.com


Welcome to the John Morris Group We are proud of our family-owned heritage spanning over 60 years & specialise in the supply, installation & servicing of precision instruments covering diverse industry sectors througout the South Pacific region

We pride ourselves in the full range of services we offer: Qualified product specialists

Experienced engineers

who possess in-depth expertise in designing the right result for your needs

who can install your instrument as well as train your staff

Highly trained sales personnel

Customer support team

who come to you to understand your needs & tailor individual solutions

who can immediately assist you over the phone, by email or live chat via our website

National office network

Quality products

delivering local assistance & timely support to your door

from known & respected brands you can trust

Maintenance & repair division

which stands behind each & every product we sell

Actually try a product

in your laboratory prior to committing to a purchase

Australian & New Zealand compliance

C E L E B R A T I N G

60 YEARS OF EVOLUTION

through electrical testing prior to delivery on every instrument we deliver

Genuine local product warranty

backed by a stable organisation that will be around in the years to come

‌ plus our web site

www.johnmorrisgroup.com For our team it’s about more than simply offering a great product. We commit to serving your end-to-end needs & would love the opportunity to become your laboratory solutions partner. The John Morris Group team is known to be amongst the most knowledgeable in the industry & our obligation is to provide the right solution for you. On behalf of the John Morris Group I look forward to helping you drive your research & testing further. Kind regards,

Andre Wyzenbeek Managing Director John Morris Group

AWyzenbeek@johnmorrisgroup.com

www.johnmorrisgroup.com

2


INDEX PHYSICAL PROPERTIES Density Meters

8

Powder Flow Testing

7

Rheology

6

Texture Analysis

9

Viscometers - In-Line

5

Viscometers - Laboratory

4

COMPOSITIONAL ANALYSIS Ash Analysis

Filtration Pumps

Industrial Vacuum Solutions

LABORATORY ESSENTIALS Balances & Scales

58

Centrifugation

59

Homogenisers

55

Laboratory Filtration

43

Manual Sampling

Calorific Analysis

18

Peristaltic Pumps, Pump Heads, Tubing

Carbohydrate Analysis

15

pH Meters

26

Pipettes

10, 11, 12, 14, 16, 21, 22

50, 51

Carboys & Containers

16, 24

Fat Analysis

57 46, 47

Beer Bitterness Determination

Dairy Product Testing

56, 57 65 52, 53 49 48

Sample Temperature Control

62, 63, 64

Fiber Analysis

18, 19

Shakers

60

In-Vitro Incubation

18

Stirrers

61

18

Tubing Connectors

54

Melting Point Moisture Analysis

11, 12, 14, 16, 17, 24, 26

NIR Analysis

16, 31

NMR Analysis

10, 12, 13, 14

Protein Analysis

11, 12, 14, 16

Sample Digestion

24, 25, 40, 41, 42

Sample Size Reduction

35,36, 37

Soxhlet Extraction

11, 21, 22

Colour Measurement

Microscopes

TRADE WASTE

20, 23

Sample Drying/Stability Ovens

OPTICAL ANALYSERS

Automatic Samplers

66, 67

Flow Meters

68, 69

CONDITION MONITORING Accelerometers

70

Bearing Fault Detection

70

Vibration Transmitters & Switches

71

PERSONAL PROTECTION

28, 29

Apparel

72

Milling, Grinding & Cutting

35-37

Flash Point Analysis

73

Particle Size Analysis

34, 35

Noise Dosimeters

73

Configuration Guides

74 - 87

Polarimetry

27

32

Raman Spectrometers

33

Refractometers

30, 31, 32

Spectrophotometers

SEPARATION SCIENCE

33

Chromatography

38, 39, 41

Solvent Evaporation

24, 40, 41, 42

FERMENTATION

VACUUM PUMP SOLUTIONS

Bioreactors

44

Colony Counters

45

Gas Sensors

45

This guide has solutions to help your team in the following areas

R&D Product Design

QC Raw Material

QC Finished Product

QC Manufacturing Plant Condition Monitoring

3

QC Effluent

Australia - Free Call: 1800 251 799


PHYSICAL PROPERTIES Viscometers - Laboratory

(refer Selection Guide on page 74 to personalise your needs)

Economic

DVE

DV1

Affordable digital viscometer Easy-to-use Display in: Viscosity (cP or mPa•s) % Torque Speed (rpm) Spindle used Digital display

▀▀ ▀▀ ▀▀

▀▀

▀▀ ▀▀

▀▀ ▀▀

DV2T

Large, easy-to-read screen Senses & continuously displays: Viscosity (cP or mPa•s) % Torque Speed (rpm) Spindle used Temp (optional) Time measurement function PC Interface & connection to printer

▀▀

Low viscosity materials

▀▀

Medium viscosity materials

▀▀

High viscosity materials

▀▀

Higher viscosity materials

▀▀ ▀▀

▀▀

Touch-screen - includes viscosity, temp, shear rate/stress, % torque, spindle/speed Built-in modules include: Timed tests Data averaging Programmable QC limits Custom speed/spindle lists On screen data comparison Perfect for QC labs & R&D depts

Servicing Brookfield Ametek Instruments

Each viscometer has a choice of 4 spring torques:

Versatile

Workhorse

As Australia’s only authorised distributor we verify, calibrate & service all Brookfield instruments - choose from:

(eg inks, oils & solvents)

(eg creams, food & paints)

▀▀ ▀▀

On-site at your premises; or At our state-of-the-art service centre

(eg gels, chocolate & epoxies) (eg asphalt, caulking compounds & molasses)

Helipath Stand

Spindles

Measurement of non-flowing substances & will permit viscosity/ consistency measurements in relative centipoise values for materials having characteristics similar to paste, putty, cream, gelatin or wax when used with a suitable Brookfield viscometer/ rheometer fitted with a special T-bar type spindle

www.johnmorrisgroup.com

A variety of spindles, cups, chambers, extensions & other specialty items are available - such as holders & quick connect couplings to allow for a wide measurement range

4


Physical Properties Compositional Analysis

Viscometers - In-Line Flange Mount Applications ▀▀ ▀▀

▀▀ ▀▀ ▀▀

Optical Analysers

▀▀

Shear rates 10 to 1,000 sec-1 Pressure up to 500 psi (34 bar) & temperatures up to 260°C Continuous measurement eliminates need for ‘Grab’ sampling & allows for prediction & control of final product properties 4-20 mA output signal Flange mountable directly into tank or in pipeline tee Rugged 300 series SS construction

Separation Science

TT-200

Direct In-Line Viscosity Measurement ▀▀ ▀▀ ▀▀ ▀▀

▀▀ ▀▀

Viscosity range: 2 to 12,500 cP Temperature range: -20°C to +200°C No moving parts to wear, bind or contact process materials Simple clean-in-place design Rugged 316 SS construction 4-20 mA output signal Easy installation Digital display

Vacuum Pump Solutions

▀▀

Fermentation

▀▀

AST-100

Laboratory Essentials

Sanitary Viscometer ▀▀ ▀▀ ▀▀

▀▀ ▀▀

Trade Waste

▀▀

Viscosity range: 350 - 250,000 (cP/mPa·s) Conforms to 3A sanitary conditions & has clean-in-place design Continuous measurement eliminates need for ‘Grab’ sampling & allows for prediction & control of final product properties Concentric cylinder geometry (Couette type) provides viscosity measurements at defined shear conditions Constant or variable speed motors 4-20 mA output signal

STT-100

Condition Monitoring

Portable & Submersible Viscometer ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

VM-250 Series

5

Australia - Free Call: 1800 251 799

Configuration Guides

▀▀

Viscosity measurements directly in storage tanks (up to 6 meters) Sensors can be submersed at any level & record spot viscosity & temperature Hundreds of measurements stored locally & transferred via built-in Bluetooth connectivity Robust design for heavy duty year-round indoor or outdoor operation Viscosity Range 0.2 to 2000 mPa·s (0.2 to 2000 cP) Viscosity Accuracy ±1% of Span Viscosity Repeatability ±0.5% of Span Temperature Range -40°C to +85°C

Personal Protection

▀▀


Rheology Measure Viscosity & Yield Stress … All-in-One ▀▀ ▀▀ ▀▀ ▀▀

▀▀

▀▀

Affordable upgrade from a viscometer 18 cm full colour touch-screen display with real time graphing Analyse yield stress, flow curves (mixing, pumping, spraying), levelling & recovery Displayed info: Viscosity (cP or mPa•s) Temperature Shear Rate/Stress % Torque Speed/Spindle Step Program Status Built-In options: Temperature Control Yield Tests Programmable QC Math Modelling Limits/Alarms Built-in RDT temperature probe Sample data display

DV3T

Soft Solids Tester ▀▀ ▀▀ ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Ideal for your pastes, slurries & materials with particulates Quantifies properties like wobbliness, sloppiness, consistency & texture Measures: Yield Stress Shear Modulus Recovery Creep Capable of measurements in BU units for viscous material such as joint compound Spindle barcode for auto spindle recognition User-friendly LCD touch screen with graphical display 11 memory slots for structured multi-step test programs Can also be used with coaxial cylinders for flow curve analysis Software for PC control & data management Popular applications: Chocolate: for manufacturers who run 24/7 operations Dairy: measures low viscosity (<0.1 Pa•s) with double-gap geometry

RST-SST

www.johnmorrisgroup.com

6


Physical Properties

Powder Flow Tester

Compositional Analysis

(refer Selection Guide on page 75 to personalise your needs) Analyse the behaviour of your powder flow Perfect for: Manufacturers: who process powders & have flow problems with bins, hoppers, silos & feeders QC check: for incoming materials & final product shipments R&D tool: to predict flow behaviour for new formulations before scale-up ▀▀

▀▀

Data Output: Flow Index Arching Dimension Rat-Hole Diameter Hopper Half Angle Gravity Chute Angle Bulk Density Curve

Separation Science

Optical Analysers

▀▀

Shearing algorithm captures Peak Stress Value, Subsequent Stable Stress Value, Recognizes ‘slip stick’ materials

Ideal for multiple applications: Beverages Cosmetics Chemicals Dairy/Cheese Detergents Equipment Manufacturers (silos/hoppers, feeders) Food (biscuits, cereal, chocolate/cocoa, flavourings/ seasonings, flour, spices, sugar, baby formula, baking soda, brownie mix, grated cheese, ground coffee, corn starch, powdered milk) Healthcare Products (tablets) Paints/Coatings/Pigments Personal Care Products (talcum powder) Pharmaceuticals Starch

Fermentation

▀▀

Vacuum Pump Solutions Laboratory Essentials

Normal Stress (kPa)

7

Australia - Free Call: 1800 251 799

Configuration Guides

Major Principal Consolidating Stress (kPa)

Personal Protection

Shear Stress (kPa)

Unconfirmed Failure Strength (kPa)

Sample Stress Data Graph

Condition Monitoring

Sample Flow Function Graph

Trade Waste

PFT Powder Flow Tester


Density Meters Portable & Submersible (up to 30 metres) ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Perfect for liquid density & temperature measurements directly in storage or process tanks Sensor is submersed at any level & records spot density & temperature Hundreds of measurements stored locally available via built-in Bluetooth connectivity Backlight LCD facilitates Density Range 0 to 3 g/cm³ Density Accuracy Up to ±0.0003 g/cm³ Density Repeatability Up to ±0.00015 g/cm³ Density Resolution 0.0001 g/cm³ Temperature Range -40°C to +85°C

DM-250

Multi-Point Density Measurement Spot density/concentration/temperature at up to 6 points Assembly includes multiple pipe sections with 1 to 6 sensor modules ▀▀ Probe assembly is delivered in sections of varying length (usually 1.5 m to 2.4 m long) depending on tank height & number of sections included ▀▀ Each sensor module is pre-assembled with a section of stainless steel pipe along with sensor cables ▀▀ Design provides smooth pipe surface over all the probe assembly & makes it easily applicable in tanks with cone & floating roofs (seals) ▀▀ All wires terminate in explosion proof, aluminum housing on top of the probe ▀▀ Density Range 0 to 3 g/cm³ ▀▀ Density Accuracy Up to ±0.00025 g/cm³ ▀▀ Density Repeatability Up to ±0.000125 g/cm³ ▀▀ Density Resolution 0.0001 g/cm³ ▀▀ Temperature Range -40°C to +85°C ▀▀ ▀▀

MDM-46

In-Flow Density Measurement ▀▀ ▀▀

▀▀ ▀▀ ▀▀ ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Real-time, in-situ monitoring Received measurements (real density: g/cm3, kg/m3) are instantly converted to relative density (specific gravity): 15°C, 20°C, API; % Alcohol; °Brix; °Baumé Uses proven vibrating element technique Pt-1000 probe continuously monitors liquid temperature Insensitive to plant vibration, high variation of temperatures or turbulence Choice of wetted parts materials - stainless steel, Ni-Span-C (for demanding applications) & Hastelloy (for ultimate corrosion resistance) Density Range 0 to 3 g/cm³ Density Accuracy Up to ±0.00025 g/cm³ Density Repeatability Up to ±0.000125 g/cm³ Density Resolution 0.0001 g/cm³ Pressure Range Up to 100 Bar Temperature Range -200°C to +200°C

DC-50

www.johnmorrisgroup.com

8


Physical Properties

Texture Analysis Compositional Analysis

(refer Selection Guide on page 76 to personalise your needs)

Compression & Tension Testing ▀▀ ▀▀ ▀▀

Elasticity Breaking Point Yield Point Relaxation

Cohesiveness Gel Strength Tackiness Adhesiveness

Burst Strength Ripeness Consistency Firmness

Pharmaceutical Gelatin

Materials Mechanical Devices

Multiple Applications: Food Personal Care

Cosmetics Packaging

Separation Science

▀▀

Hardness Fracturability Spreadability Pliability

Optical Analysers

Economical high-end texture analyzer Easy-to-operate & suitable for R&D & QC Extremely versatile with over 300 accessories to measure force/ compression of hundreds of sample types:

Fermentation Vacuum Pump Solutions Laboratory Essentials

CT3 Texture Analyzer

Trade Waste

Some of the many probes, fixtures & jigs - call us for a complete list: Fixture base table

Rotary base table

Three point bend fixture

Pasta firmness & stickiness

Hardness puncture test for fruit & vegetables Condition Monitoring

TA-BT-KIT

TA-KF

Shear Blade for cutting tests - meat, poultry, fish or similar products

TA-52 MOHRS

9

TA-FFS-C

Measure consistency of applesauce, pudding, yogurt, etc

TA-BEC

TA-MPT

Wire Shear Plate for significant stickiness (eg cheese & butter)

TA-WSP

Australia - Free Call: 1800 251 799

Configuration Guides

TA-CJ

Force & distance to break the sample

TA-TPB

Personal Protection

Confectionary fixture for penetrating test

TA-RT-KIT


COMPOSITIONAL ANALYSIS Rapid Fat Analyzer - Zero Method Development! (refer Selection Guide on page 77 to personalise your needs)

Primary Method Without Wet Chemistry Patented, breakthrough NMR technology - completely isolates the detection of the proton signal in fat molecules from all other compositional proton sources (i.e. protein, carbohydrate, ash) making a universal fat analyzer possible ▀▀ Analyze fat in any food sample with reference chemistry accuracy, without any prior knowledge of the sample matrix & composition ▀▀ Results in <30 seconds - accurate & precise fat results ▀▀ Automation options available for high throughput laboratories (50+ samples per day) ▀▀ Sophisticated software o Select individual results for detailed analysis o Sort data, run QC tests & run diagnostics ▀▀

Oracle

Perfect for fat analysis on ...

Meats

▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Dairy

Bacon Cod (Raw) Chicken (Deli) Chicken (Raw) Duck Ground Beef Ham (Deli) Hot Dog Lamb Pork (Raw) Salmon (Raw) Sausage Turkey Venison

▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Butter Cheese (Cream) Cheese (Enzyme Modified) Cheese (Fresh) Cheese (Hard) Cheese (Processed) Chocolate (Milk) Cream (Heavy) Egg Whites Formula (Infant) Ice Cream Mix Milk (Almond) Milk (Chocolate) Milk (Skim) Milk (Whole) Yogurt

Food/Feeds

▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Coffee Creamer Chips (Baked) Chips (Corn) Chips (Fried) Chips (Potato) Cookies Crackers Dog Food Dough Dressings Gravy Granules Guacamole Mayonnaise Mixed Foods Noodles (Flour) Noodles (Rice) Nutritional Drinks Puddings Poultry Feed Soup Stock

Powders

▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Cheese Coffee Creamer Dairy (Low-Fat) Formula (Infant) Gravy Milk (Non-Fat) Milk (Whole) Non-Dairy Whey Milk (Non-Fat) Wheat Flour

For rapid moisture/solids analysis in addition to fat analysis, Oracle can be paired with the SMART 6 analyzer for moisture/solids results in <5 minutes (refer page 17)

www.johnmorrisgroup.com

10


Physical Properties

(refer Selection Guide on page 77 to personalise your needs) ▀▀

▀▀

▀▀ ▀▀

Separation Science

▀▀

Optical Analysers

▀▀

Combines microwave moisture measurement with data analysis to rapidly evaluate beef, pork, chicken & turkey meat Analysis can be used for process control to make blend corrections, release materials & ensure least cost formulation Measures fat, moisture & protein in raw meat & meat blends in <3 minutes! No hazardous waste, low energy requirements Comes ready to analyze raw meat & blends with pre-programmed methods Uses official AOAC method 2008.06 to rapidly measure the moisture content & a simple curve fitting program to provide the best estimate of fat & protein content

Compositional Analysis

Fat, Moisture & Protein Analysis of Raw Meat & Meat Products

Fermentation Vacuum Pump Solutions

Smart 6 ProFat Meat Analyzer

Fat/Oil Analysis - Automated Soxhlet Type Extraction ▀▀

Laboratory Essentials Trade Waste

Accelerate extraction kinetics thanks to 90°C internal temperature Most extraction times reduced by up to 40 minutes ▀▀ Solvent recovery & recycling is done automatically at a rate ~97% ▀▀ Solvent usage per sample ~0.5 mL ▀▀ Microprocessor controlled with LCD readout ▀▀ No need for a vent hood due to automatic solvent recycling & activated charcoal filter ▀▀ Filter bag technology enables batch processing: o up to 15 samples/run o 150 samples/day ▀▀

XT15 Extractor

Condition Monitoring

Simplified Fat Hydrolysis System ▀▀

▀▀

▀▀

▀▀

HCI Hydrolysis System

11

Australia - Free Call: 1800 251 799

Configuration Guides

▀▀

Personal Protection

▀▀

Automated method for performing the hydrolysis step in total fat/oil analysis - allowing for batch hydrolysis Process up to 45 samples per day Insert up to 15 samples at one time into vessel, add the acid solution & follow the screen prompts Once the program is selected, the system automatically completes the process & rinses the samples Closed system (less exposure to acids & increases safety) Small footprint


NMR Benchtop Systems

(refer Selection Guide on page 77 to personalise your needs)

Versatile NMR - Replace Wet Chemistry Multi-nuclear NMR & variable frequency (5 to 60 MHz) Remote control, system logging & daily check ▀▀ Application pool contains all standard & advanced applications ▀▀ Wide range of probe heads (absolute, ratio, combined, temperature controlled, gradients), temperature range: -100°C to +200°C ▀▀ Fast magnet warm-up & precise digital temperature for stability of results ▀▀ Highly linear fast signal detection ▀▀ No sample preparation & replaces wet chemical & physical tests ▀▀ Unaffected by sample colour & surface properties ▀▀ Perfectly suited for QA/QC & R&D requirements ▀▀ Food applications include: o Solid fat content (AOCS Cd 16b-93, ISO 8292 & IUPAC 2.150) o Oil & moisture in seeds & oilseed residues (AOCS Ak4-95, ISO 10565 & 10632 - USDA GIPSA approved) o Solid fat content plus total fat content in chocolate & related products o Droplet size analysis in O/W & W/O emulsions o Oil, water & protein in dry & wet food & feed ▀▀ ▀▀

Minispec Mq Series

Minispec Plus m+ Software

One Solution for Your QC Applications Not just a benchtop system or mini NMR system - it is a dedicated analyzer providing a complete solution ‘off the shelf’ ▀▀ Suitable for routine industrial applications ▀▀ Easy installation, comprehensive calibration & calibration transfer standards ▀▀ 21 CFR part 11 compliant ▀▀ Food industry applications include: o Solid fat content o Fat analyzer o Seed analyzer ▀▀

Minispec Mq-One

Sample Automation ▀▀

▀▀

▀▀

Available as a standalone accessory to existing Minispec systems or as a packaged system with a new Minispec spectrometer SFC Sample Automation system automatically & accurately controls tempering times delivering results in strictest accordance to SFC International Standard Methods Automation for all other major Time Domain-Nuclear Magnetic Resonance (TD-NMR) Minispec applications

Minispec Automation

www.johnmorrisgroup.com

12


Physical Properties

Rapid detection of adulteration & mislabelling of content or origin - analyze quality with regard to authenticity based on 1H-NMR-Profiling

Compositional Analysis

NMR FoodScreener Solutions Honey

Fraud: Addition of Rice-Syrup

Separation Science

▀▀ ▀▀

▀▀ ▀▀ ▀▀

Direct & absolute quantification of 56 parameters in any wine - distribution of reference values available Verification of several countries of origin for red & white wine Verification of region of origin for main regions in France, Italy & Spain Verification of 23 grape varieties Verification of the three most recent vintages for white wines Screening for water addition in red & white wines Detection of any deviation to reference wines in a non-targeted way, for red & white wines

≈4% of overall NMR-profile

New test sample (black line)

Laboratory Essentials

▀▀

Sample Verification

Vacuum Pump Solutions

Wine

Fermentation

H-Chemical Shift -3% of NMR-Profile

1

▀▀

Optical Analysers

Sample Verification

Combining targeted (quantification) & non-targeted (statistics for classification & verification) approaches: ▀▀ Simultaneous identification & absolute quantification of a multitude of relevant parameters (sugars, acids, amino acids, etc) ▀▀ Development of statistical models for the analysis of authenticity according to honey variety (such as blossom, honeydew, linden, lavender, chestnut, pine) & according to geographical origin ▀▀ Detection of frauds like addition of rice syrup or other types of sugar ▀▀ Detection of unknown frauds ▀▀ Statistical modelling based on a reference database containing thousands of authentic samples with world-wide coverage

H-Chemical Shift

1

Trade Waste

Fruit Juice

▀▀ ▀▀

▀▀

▀▀

Model: 100% Pomegranate Juice

Adulterated Sample

Statistical analysis & concentration distribution curves of all compounds quantified are based on an extensive NMR spectroscopic database of more than 16,000 reference juices, obtained from production sites

13

Australia - Free Call: 1800 251 799

Configuration Guides

H-Chemical Shift - 7% of NMR-Profile

1

Personal Protection

▀▀

Automated push-button evaluation & reporting solution Provides targeted & non-targeted multi-marker analysis Targeted Analysis: Simultaneous absolute quantification of relevant organic compounds with reference to A.I.J.N. & NMR distribution Non-Targeted Analysis: NMR profile is compared with the corresponding group of reference spectra Deviating concentration levels & even unknown signals are detected automatically

Condition Monitoring

▀▀

Sample Verification


Rapid Protein Analyser - Dairy & Meat (refer Selection Guide on page 77 to personalise your needs)

▀▀ ▀▀ ▀▀ ▀▀

▀▀

▀▀

Rapid, safe & direct determination of protein (not nitrogen) Safer than Kjeldahl with better results Protein Range 0.01% to 99.99% in liquids, solids & slurries Complies with official AOAC Methods 2011.04, 967.12, 930.33 & 930.29 No hazardous waste for disposal - the sample non-toxic solutions are environmentally friendly Each Sprint Pak contains 50 disposable cups with lids, 50 disposable filters & iTAG solutions for 50 tests

SPRINT™

Applications

How It Works

All proteins contain amino acids – the basic amino acids that are found in foods are Arginine, Histidine & Lysine

Dairy: Yogurt, Greek yogurt, cheese (natural), cheese (processed), cheese (cottage), cheese (cream), sour cream, cream cheese, heavy cream, infant formula, milk (fluid), milk (non-fat dry), milk (condensed skim), milk (whole milk powder), buttermilk, chocolate milk, ice cream, whey (condensed), whey (rennet)

Meat: Beef, beef liver, pork, chicken, chicken liver, turkey, hot dog, pepperoni, hard salami, ham, processed meats, sausage

CEM’s iTAG solution binds to these 3 amino acids using an acid group - the aromatic portion of the molecule absorbs light & is easily detected with a colorimeter

Food: Eggs (whole, yoke, white), peanut

Acid

meal, soy beans, wheat flour

Aromatic group that absorbs light & appears orange

www.johnmorrisgroup.com

14


Physical Properties

Carbohydrate Analyser

Compositional Analysis

(refer Selection Guide on page 79 to personalise your needs)

CE compliant

Optical Analysers

YSI enzyme electrodes Video training

Separation Science Fermentation Vacuum Pump Solutions

Flexible sampling tubes or plates

Versatile connectivity

Laboratory Essentials

Slim benchtop profile

Easy access for maintenance

Trade Waste

2900 Series

Condition Monitoring

Versatile - measure >10 chemistries Analysis time <1 minute ▀▀ Analyte-specific results - even in complex matrices ▀▀ Intuitive graphical user interface with touch-screen display ▀▀ Accepts a wide range of sample holders - 96 well, 4/8/24 place test tube ▀▀ Modular - expandable from 2 to 6 chemistries ▀▀ Anti-clogging fluidics & chamber design (measure high cell density samples with ease) ▀▀ Measure various food & beverage chemistries: o Primary applications: Glucose, Lactate, Glutamate, Ethanol, Sucrose, Lactose, Choline o Secondary applications: Glutamine, Ammonium, Potassium, Glycerol, Hydrogen Peroxide ▀▀ ▀▀

Personal Protection Configuration Guides

15

Australia - Free Call: 1800 251 799


NIR Solutions

(refer Selection Guide on page 77 to personalise your needs)

FT-NIR Top Performance ▀▀ ▀▀ ▀▀

▀▀ ▀▀ ▀▀ ▀▀

Control the quality & nutritional facts of your feed, pet-food, milling & bakery products World’s first dedicated FT-NIR standalone spectrometer available in food-grade PMMA or stainless steel Accurate & reproducible performance of polarization FT technology with certified dust protection meets the cleaning processes requested for at-line machinery Precise measurement of multiple parameters simultaneously Exact data through top wavelength precision guaranteed by internal laser system Maximum reliable reads through vibration proof FT polarization interferometer Continuous operation with twin-lamp safeguard NIRMaster™

Modular FT-NIR Spectrometer ▀▀

▀▀ ▀▀ ▀▀

▀▀ ▀▀

Reliable analysis results for quality control plus R&D in food, beverage & feed industry Wide range of measuring cells & accessories for highest performance Direct & effortless transfer of calibrations from instrument to instrument Quickly & precisely analyzes different sample types (solid, powder, tablet, granule, paste, liquid, etc) by dedicated measuring options Delivers results in seconds with no chemicals or solvents Obtains several parameters simultaneously

NIRFlex N-500

IP65 Precision FT-NIR ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

World’s first dedicated FT-NIR standalone spectrometer with IP65 protection Complies with dairy & meat production safety of quality control instrument requirements Highly reproducible results with polarization FT-NIR technology Precise measurement of multiple parameters simultaneously Exact data through top wavelength precision guaranteed by internal laser system

NIRMaster™ Pro IP65

Analyze Protein, Oil & Moisture Content Anywhere! ▀▀ ▀▀ ▀▀

▀▀ ▀▀

Designed for rugged use - take with you on the plant floor or in the field. Analyzes protein & oil both on an ‘as-is’ basis & a constant moisture (CM) basis Simply pour sample into sample holder & place holder into the meter results displayed in <1 minute Download data to PC with the included calibration software & RS-232 cable Oil calibration is included with corn, soybean, canola, mustard & flax calibrations (each additional calibration is additional cost)

Portable NIR Food Analyzer Kit #59824-00

www.johnmorrisgroup.com

16


Physical Properties

Rapid Moisture & Solids Analysis

Compositional Analysis

(refer Selection Guide on page 77 to personalise your needs)

One System - Limitless Testing Ideal for process & quality control for a variety of samples including liquids, solids, powders & slurries (0.01% to 99.99% moisture) ▀▀ Accurately determines the moisture, solids or volatiles content with accuracy & less time: Cheese: 90 seconds Milk Powder: 70 seconds Latex: 60 seconds Salad Dressing: 90 seconds ▀▀

Optical Analysers

Eliminate burning of samples & variations caused by operator techniques ▀▀ Easily review data with options to perform statistical analyses within the system ▀▀ Decrease the energy needed for conventional moisture/solids analysis by 95%

Separation Science

▀▀

Fermentation

Interactive touchscreen - intuitive testing process that clearly displays results & includes training videos ▀▀ No costly calibrations ▀▀ Complies with AOAC Official Methods 985.14, 985.26 & 2008.6 ▀▀ Package includes 200 glass fiber sample pads, 2 balance pans, 2 balance stems, 1 sample press, monitor kit, 5 pipettes, 10 g calibration weight, Setup Guide ▀▀

Smart 6

Vacuum Pump Solutions Laboratory Essentials

Moisture Analysers - Economical Trade Waste Condition Monitoring

▀▀ ▀▀ ▀▀

400 W halogen glass heater 15 memories for drying programs 50 sample plates included

DLB 160-3A ▀▀ ▀▀ ▀▀

400 W halogen glass heater 5 memories for drying programs 10 sample plates included

▀▀ ▀▀ ▀▀

Infrared + graphic display 100 memories for drying programs 10 sample plates included

External 160 g 0.001 g

17

External 50 g 0.001 g

Australia - Free Call: 1800 251 799

Configuration Guides

Calibration External Weighing Range 110 g Readout 0.001 g

MLS50-3C

Personal Protection

DAB 100-3


In-Vitro Incubation Accurate Digestibility Studies ▀▀

▀▀

Daisy Incubator

▀▀ ▀▀

Results can be determined for in-vitro: o True digestibility o Apparent digestibility o Rate studies o Neutral cellulase gamanase digestibility o Enzymatic digestions o … & other related studies for all feeds & forages Employs filter bag technology (which encapsulate samples & prevents filtration errors - enables batch processing of >100 samples per run) Economical - reduces labour >50% Small footprint - conserves counter space

Bomb Calorimeters The 6400 & 6200 are isoperibol calorimeters - where the surrounding jacket is maintained at a constant temp while the temp of the bomb & bucket rise as heat is released by the combustion (meets all ASTM, ISO & Australian Standards )

High Throughput

High Precision

Model 6400

Specifications

Calorimeter Type

Model 6200

Isoperibol

Isoperibol

PC Controlled

Model 6050

Compensated

Operator Time per Test

1 minute

6 minutes

6 minutes

Precision Classification

0.10% RSD

0.05% to 0.10% RSD

0.20% RSD

Number of Vessels Tests per Hour Bomb Type & Bucket

Up to 4

Up to 4

Up to 8

6 to 7

4 to 8 (as equipped)

4 to 6 (as equipped)

Fixed bomb & bucket design

Removable bomb & bucket design

Removable bomb & bucket design

Bucket Filling

Automatic

Manual

Manual

Bomb Washing

Automatic

Manual

Manual

Melting Point Easy & Fast Determination ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Designed for manual determination of melting & boiling points Easy observation of melting process through a magnifying lens Highly accurate temperature setting & measurement Easy verification of calibration using certified standard compounds Shortened measurement cycles due to fast heat up & cool down steps First quick estimation possible using a temperature gradient up to 20°C/minute Parallel measurement of up to 3 samples Optional printer for GLP/GMP-conform documentation of results of calibration, melting & boiling point determination

www.johnmorrisgroup.com

18

M-560


Physical Properties

Fiber Analysis

Compositional Analysis

(refer Selection Guide on page 81 to personalise your needs)

Automated Total Dietary Fiber Analyser Reduces labour & cost per sample while increasing accuracy & precision Automates AOAC 991.43/AACC 32.07.01 (upgrade available to support AOAC 2009.01 & 2011.25) ▀▀ 18 samples (9 in duplicate/day) ▀▀ Automates the addition of chemical solutions, enzymes & rinses ▀▀ Temperatures & agitation levels controlled throughout the process - eliminating multiple water baths & freeing up precious lab space ▀▀ Advanced filter bag technology increases filtering surface area which reduces the time needed to filter samples & eliminates the use of vacuum flasks & crucibles ▀▀ ▀▀

Optical Analysers Separation Science

TDF Fiber Analyser

TDF Fiber Analyser Consumables & Bags Fermentation

α-Amylase Concentrate 100 mL

α-Amylase Concentrate 20 mL

Amyloglucosidase Concentrate 100 mL

Protease Concentrate 100 mL

Protease Concentrate 20 mL

MES 250 g

Dietary Fiber Flow Thru Bag

Dietary Fiber IDF Bag

Amyloglucosidase Concentrate 20 mL

Dietary Fiber SDF Bag

Laboratory Essentials

α-Amylase (Porcine Pancreatic) 2g

Vacuum Pump Solutions

TRIS 250 g

Crude Fiber Analyser Increased automation to enhance laboratory operations & reduce labour costs Samples are prepared using Filter Bag Technology ▀▀ Automation eliminates chemical & hot water handling ▀▀ Fiber test results determined for all feeds & forages: o Acid Detergent Fiber (144 samples per day) o Neutral Detergent Fiber (120 samples per day) o Crude Fiber (96 samples per day) ▀▀ Most elements of technician variability are eliminated & there is no separate filtration step - accurate & consistent results are achieved time after time ▀▀ Requires little bench space ▀▀ Up to 24 samples per batch ▀▀

Trade Waste

▀▀

Condition Monitoring

Accessories Personal Protection

Acid Detergent (Dry CTAB Powder Dilutes to 20 L with 1N-H2SO4)

19

Fiber Filter Bags (200)

Fiber Filter Bags (100)

Heat Sealer

Australia - Free Call: 1800 251 799

Configuration Guides

2000 Fiber Analyser


Digestion

(refer Selection Guide on page 82 to personalise your needs)

Batch Acid Digestion ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Utilises high pressure, closed vessels that enable safe digestion of up to 40 samples per cycle (volume from 10 to 100 mL) Accurate monitoring of temperature & pressure across all vessels High resolution, acid resistant touch screen with pre-programmed methods library Helps determine method parameters, requiring minimal experience from the end user PowerMAX™ power control technology delivers maximum energy to the samples for complete digestion

EasyPrep™

High-temperature, high-pressure vessel, requires no membranes or springs for reliable pressure control

Manage your lab from your mobile device

Direct, in situ temperature sensor

iLink

iWave

iPrep™

Digests up to 2x more samples per run (110 mL volume), has ‘dual seal’ vent plug (achieving complete digestion of difficult samples) & uses simple hand tool to seal vessel (reducing hand fatigue).

MARS 6

Sequential Acid Digestion ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

▀▀

Sequential, pressurized microwave digestion system processes samples in <10 minutes (including cool down) Range of pressurized vessels available (10, 35 or 80 mL), all with snap-on caps Easy to set up & enables individual sample programming Reproducible microwave field for rapid processing of samples Safely vents any excess gaseous by-products without loss of analytes Individual control removes the need to batch samples (allowing the chemist to mix & match sample types) Digest any sample size: micro to multi-gram scale

Discover SP-D 80

www.johnmorrisgroup.com

20


Physical Properties

Extraction

Compositional Analysis

(refer Selection Guide on page 82 to personalise your needs)

Batch Extraction ▀▀ ▀▀

▀▀ ▀▀

Optical Analysers

▀▀

Utilises high pressure, closed vessels that enable the safe extraction of up to 40 samples per cycle Accurate monitoring of temperature & pressure across all vessels EPA 3546 approved method Significant solvent reduction aiding in ‘green chemistry’ initiatives Replaces soxhlet & ASE technology

Separation Science

Manage your lab from your mobile device

Fermentation

iLink

Glass Liners

MARS 6

Vacuum Pump Solutions

MarsXpress™

High-throughput vessel assembles in seconds, works in conjunction with Contactless Temperature Control

Laboratory Essentials Trade Waste

Sequential Extraction Significantly reduce solvent usage and decrease extraction times from hours to minutes with automated microwave extraction, hydrolysis or derivitizations ▀▀ Ideal for a wide variety of matrices, including foods, plastics & polymers, environmental samples, textiles and more ▀▀ Reduce solvent usage by up to 95% ▀▀ Typical extractions in <10 minutes (including cool down) ▀▀ Full temperature & pressure control of each vessel ▀▀ Easy-to-use vessels with snap-on caps ▀▀ Works with all solvents, including polar & non-polar ▀▀ Accommodates a wide range of sizes ▀▀ Documentation of every sample ▀▀ Stirring provides uniformity of mixture ▀▀

Condition Monitoring Personal Protection

21

Australia - Free Call: 1800 251 799

Configuration Guides

Discover SP-X


Automated Fat Determination ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Low solvent consumption due to the compact design of the glass assembly >90% recycling yields due to minimized solvent emission & cooled tank Intuitive solvent library provides quick & simple method selection Up to four times faster compared to extractions using classical glassware Continuous extraction method provides high reproducibility & reliable results High speed heating due to ceramic plates & individual heating zones

Extraction Unit E-816 ECE

Combine Maximum Speed & Throughput ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Ideal solution for fast Pressurized Solvent Extraction (PSE) Process up to 6 samples in parallel 6 times faster than other PSE instruments due to parallel extraction concept Extract up to 96 samples in an 8 hour shift Reduce number of replicates due to identical extraction conditions for up to 6 samples Unique design of extraction cells allows for ease of sample loading & cell assembly Automated sealing eliminates sources of error & guarantees safety standard Complementary workflow & synergy with parallel evaporation & concentration Reduced solvent consumption & consumables for lower running costs SpeedExtractor E-914/E-916

Four Compliant & Versatile Extraction Methods ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Run four different methods Soxhlet, Soxhlet Warm, Hot Extraction & Continuous Flow Ideal for demanding applications in residue & contaminant analysis Reach the required detection limit thanks to 60% larger sample volume (LSV configuration) Compatible with many solvents and samples Contamination free instrument due to autoclavable parts No alternating blank values Better recoveries by drying under inert gas Minimized solvent loss thanks to high performance condenser

Extraction System B-811/B-811 LSV

Cost-Effective Hydrolysis ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Simultaneous hydrolysis, filtration & rinsing of up to 6 samples simultaneously Compliant with official regulations (eg AOAC, ISO, DIN) for declaration of total fat content Convenient transfer of the hydrolysate without getting in contact with the sample Effective sealing avoids harmful emissions Fast & effective heat transfer to samples by means of IR radiation Sample tube designed to use directly with E-816 or B-811

Hydrolysis Unit E-416

(refer Selection Guide on page 82 to personalise your needs)

www.johnmorrisgroup.com

22


Physical Properties

Kjeldahl

Compositional Analysis

(refer Selection Guide on page 77 to personalise your needs)

Broad Application Flexibility ▀▀ ▀▀

▀▀ ▀▀ ▀▀ ▀▀

KjelFlex K-360

Separation Science

▀▀

Optical Analysers

▀▀

Perform Kjeldahl nitrogen or protein determination & steam distillation Customisable analysis methods for multi-purpose use Connection to external titrators for semi-automated processing (for colorimetric or potentiometric procedures) Data export on USB printer for documentation purposes Acid resistant pump (for additional steam distillation applications) Reduction of steam power for gentle distillation Choice of glass or plastic splash protector No contact with hazardous chemicals due to automatic aspiration of sample tube &/or receiving vessel

Choice of Methods ▀▀ ▀▀ ▀▀ ▀▀

▀▀ ▀▀ ▀▀

KjelMaster K-375

▀▀

▀▀ ▀▀ ▀▀ ▀▀

▀▀ ▀▀ ▀▀ ▀▀

Revolution in Block Digestion ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

▀▀ ▀▀

23

Australia - Free Call: 1800 251 799

Configuration Guides

SpeedDigester K-439

Combines the benefits of infrared (IR) & block digestion in one unit Fast heat transfer of infrared heaters to samples Large time savings due to fast heating & cooling Accelerated digestion step with continuous addition of H2O2 Uses 100 mL, 300 mL & 500 mL sample tubes Optional dedicated suction module for aqueous samples Storage of up to 50 different method profiles (time/temperature) Digestion process shown graphically Thermal homogeneity due to the innovative insulation plate

Personal Protection

▀▀

Condition Monitoring

KjelDigester K-446/K-449

Trade Waste

▀▀

Reduces block digestion process by up to two hours due to acceleration of the heating & cooling step Direct transfer of the 20 position rack to the KjelSampler Unattended operation by using automatic lift & delayed start time (K-449 only) Programmable time/temperature profiles & full Scrubber K-415 control (K-449 only) Improved sealing for effective transfer of harmful fumes No user contact with hot samples due to automatic lift (K-449 only) Compliant to official AOAC, ISO & EN regulations Accurate temperature control following the programmed profile Reproducible digestion due to the improved thermal homogeneity

Laboratory Essentials

20 Position Block Digestor

Vacuum Pump Solutions

▀▀

Solutions for both potentiometric & colorimetric titrations Different access levels of authorization supported by intelligent software Reproducible results with the smart distillation mode ‘IntelliDist’ Intuitive operation via the large graphical colour touch-screen (21.3 cm) Simple LIMS integration & traceable data recording Optimal working conditions by self-adjusting cooling water control Shortest time-to-result due to well synchronized process steps Upgrade onsite for highest sample loads (by connecting the KjelSampler) Fully automated workflow for high sample loads Automatic data exchange with complementary peripherals

Fermentation

▀▀


Microwave Drying/Ashing Rapid Microwave Drying ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

SAM 225

Infrared temperature control, provides rapid drying of all sample types with reproducible results Stores up to 20 separate methods Reduce drying times from hours to minutes Each method can have up to 8 heating, cooling or heat ramping stages Time & power selections programmed for each stage - powerful, variable speed exhaust system quickly moves air through the cavity to aid in drying & can be connected to an existing laboratory exhaust when drying organic compounds

Microwave Ashing/Muffle Furnace Up to 10 times faster than conventional muffle furnaces Ash up to 15 samples at one time ▀▀ Accurate results in minutes ▀▀ Versatility - use any type of crucible normally used in conventional ashing systems, even platinum ▀▀ Choose from either: o High Temperature: Reach 1,200°C & process up to eight 25 mL crucibles o High Capacity: Ideal for labs needing greater throughput - reach 1,000°C & hold up to 15 x 25 mL crucibles ▀▀ ▀▀

Phoenix

Heating & Drying Ovens

▀▀

▀▀ ▀▀

▀▀ ▀▀ ▀▀

High Energy Efficiency

Advanced Timer Functions

Advanced Program Functions

Model FD 56

Model FED 115

Model M 400

Excellent spatial temperature accuracy Controller with LCD display Electromechanical control of the exhaust air flap Includes 2 chrome-plated racks Stackable design USB port for recording data

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

▀▀ ▀▀

Fan Forced Temp Range Interior Volume Number of Shelves

Yes Ambient plus 10°C to 300°C 60 L 2/4

www.johnmorrisgroup.com

Adjustable fan speed Controller with LCD display Includes 2 chrome-plated racks Stackable design Class 2 independent temp safety device (DIN 12880) with visual temperature alarm Ethernet interface USB port for recording data Yes Ambient plus 10°C to 300°C 116 L 2/5

24

▀▀ ▀▀ ▀▀

▀▀ ▀▀

Adjustable fan speed Program-controlled ventilation flap Colour LCD controller with timesegment programming Includes 2 chrome-plated racks Computer interface RS 422

Yes Ambient plus 5°C to 300°C 400 L 2/10


Physical Properties

Constant Climate Chambers ICH-Compliant Light Source & Light Dose Control

Series KBF - Model 240

Series KBF P - Model 720

Series KBF LQC - Model 240

Optical Analysers

Temperature/ Humidity/Light

Compositional Analysis

Large Temperature/ Humidity Range

▀▀

▀▀

▀▀

▀▀

3 positionable illumination cassettes with ICH-compliant UV/Vis light source Humidity regulation with capacitive humidity sensor & vapour humidification Time-segment programming

▀▀

▀▀

▀▀

▀▀

Temp Range Interior Volume Number of Racks

0°C to 70°C 10% to 80% RH 247 to 700 L 3 to 12

0°C to 70°C 10% to 80% RH 247 to 700 L 2 to 7

Rapid Temperature Changes with Humidity Control

Rapid Temperature Changes with Extended Low Temperature Range

Series MK - Model 115

Series MKF - Model 240

Series MKT - Model 240

Trade Waste

Rapid Temperature Changes

Laboratory Essentials

Dynamic Climate Chambers

Vacuum Pump Solutions

0°C to 70°C 10% to 80% RH 102 to 1,020 L 2 to 9

Humidity Range

2 positionable illumination cassettes with ICH-compliant UV/Vis light source Independent light-dose control of UV-A & visible light Humidity regulation with capacitive humidity sensor & vapour humidification Time-segment programming

Fermentation

Humidity regulation with capacitive humidity sensor & vapour humidification Intuitive touchscreen controller with time-segment & real-time programming with internal data recording

Separation Science

▀▀

▀▀

▀▀

▀▀

Temp Range Interior Volume Number of Racks

-40°C to +180°C 53 to 734 L 1 to 4

▀▀

▀▀

▀▀

▀▀

Integrated 20 L water-storage tank 4 zero-voltage relay contacts activated via MCS controller Programmable condensation protection for test material Heated viewing window with LED interior lighting Pt 100 temperature sensor

-40°C to +180°C 10% to 98% RH 115 to 734 L 1 to 6

25

▀▀

▀▀

▀▀

▀▀

4 zero-voltage relay contacts that can be activated via MCS controller Programmable condensation protection for test material Heated viewing window with LED interior lighting Pt 100 temperature sensor

-70°C to +180°C 115 to 734 L 1 to 6

Australia - Free Call: 1800 251 799

Configuration Guides

Humidity Range

▀▀

Personal Protection

▀▀

Programmable condensation protection for test material Heated viewing window with LED interior lighting Time-segment programming Class 2 independent adjustable temp safety device (DIN 12880) with visual alarm Pt 100 temperature sensor

Condition Monitoring

▀▀


Dairy Testing Added Water in Milk Test ▀▀

▀▀

Stir wire & sample probe

▀▀

In-built printer ▀▀ ▀▀ ▀▀ ▀▀

Fastest, most reliable & precise system to test for added water in milk supply Industry preferred freezing point depression (FPD) method for determination of added water to milk Ensure premium milk supply & improve your operating efficiency Sample volume 2.0 or 2.5 mL Test time ≈90 seconds Range from 0 to 1000 m°C (Celsius) or m°H (Hortvet) Specifically designed to satisfy ISO 5764 / IDF 108, HACCP & QA/QC requirements ▀▀ Applications: o Determining added water in raw cow, sheep, goat, buffalo & camel milks o Checkpoint indicator for sour or contaminated raw milk o Indicate the presence of water in milking machine pipes, undrained bulk tanks, etc

Model 4250

Simple push-button design Frost-free cooling chamber (eliminates most routine maintenance)

Instrument display provides tests results, user prompts, selfdiagnosis

Pasteurisation Test - Fluorophos® ALP (Alkaline Phosphatase) ▀▀

▀▀ ▀▀

▀▀ ▀▀ ▀▀

▀▀

Determines the completeness of pasteurisation & detect raw milk contamination Test results in just 3 minutes Greatest sensitivity - detects as little as 0.003% raw milk contamination Highest specificity - eliminating false positives Small sample size 75 µL Globally proven - approved by AOAC, ISO/IDF & IMS for confirming proper pasteurisation HACCP ready - ideal for use with a Hazard Analysis Critical Control Point program

FLM200

www.johnmorrisgroup.com

26


Physical Properties Compositional Analysis

OPTICAL ANALYSERS

Stereo Microscopes

Compound Microscope

Optical Analysers

Microscopes

Separation Science Fermentation

Stereo Zoom

Compound Digital Microscope

#48920-35

#OZL 451

#OBD 127

Full-Size Dual Power ▀▀

▀▀

Deliver clear 3-D images 10x/30x total magnification Excellent depth of field

▀▀ ▀▀ ▀▀ ▀▀

Excellent optical characteristics 7.5x to 50x magnification Flexible pillar design Continuously dimmable light source

Binocular Compound Microscope with 3 MP Camera 40x to 1000x magnification Infinity E-Plan optical system Includes USB cable, software & calibration scale Koehler illumination

▀▀ ▀▀ ▀▀

▀▀

Laboratory Essentials

▀▀

Flexible with Halogen Illumination

Vacuum Pump Solutions

Dual Power

Trade Waste

Microscope + Low Throughput Scanner Fully Digital - PC Operated & Viewing ▀▀ ▀▀ ▀▀ ▀▀

Touch enabled software & operation ROI scanned & digitised in 60 seconds Live scanning/stitching mode 20x, 40x, 60x & 100x Objectives Remote control operation

Condition Monitoring

▀▀

Personal Protection Configuration Guides

M8

27

Australia - Free Call: 1800 251 799


Colour Measurement

(refer Selection Guide on page 83 to personalise your needs)

Ideal for Food, Powders, Pastes, etc ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

In 1 second receive a sample reading plus a report detailing closeness of the colour to a measured standard Hand-held imaging spectrocolorimeter Takes images of sample using 8 different visible illuminations & 1 UV LED (9 bands) for more accurate colour measurement Enables setting & maintaining colour standards throughout the manufacturing process Up to 20 reference standards measured & stored - each date & time stamped Store up to 350 sample measurements & compared to the reference standards Conformance reports in PDF & Excel formats Applications include coatings, food & beverages, household products, pharmaceuticals & cosmetics, textiles, chemicals, sugar solutions, syrups & honey Scales: CIE 94, CIELAB (L*C*h), CMC Tolerancing, ASTM D7843 Easy calibration with built-in calibration plate

LC 100

Suitable for Food & Beverage, Sugar, Honey, Beer & More! ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Integrated RCMSi technology for remote calibration Automatic & non-subjective colour measurement Handles hot samples with high melting points Extensive & flexible choice of colour scales Readings in <20 seconds GLP compliant - date, time, sample & user ID Accommodates a wide range of sample cells & tubes Includes colour control software, conformance standard & cells PFXi-195 Series

Model PFXi-195/1

Application Liquid chemicals & oils

Standard Colour Scales Pt-Co/Hazen/APHA, Gardner, Iodine, CIE values, spectral data

PFXi-195/3

Dark oils & fats

FAC, Gardner, CIE values, spectral data

PFXi-195/4

Beers, malts & caramels

EBC (CIE & 430 nm), ASBC (CIE & 430 nm), Series 52 (Brown), CIE values, spectral data

PFXi-195/5

Pharmaceutical solutions

European Pharmacopoeia (includes automatic selection of colour series),

PFXi-195/6

Industrial oils & surfactants

PFXi-195/7

Sugar solutions, syrups & honey

PFXi-195/8

Water & waste waters

PFXi-195/9

Transparent samples

www.johnmorrisgroup.com

US Pharmacopoeia, Pt-Co/Hazen/APHA, CIE values, spectral data Klett Colour (blue filter KS-42), Pt-Co/Hazen/APHA, Hess-Ives Colour Units, CIE values, spectral data ICUMSA Colour (420, 560, 710 nm), Honey Colour (Pfund Equivalents), Series 52 (Brown), CIE values, spectral data ADMI (spectral & tristimulus filter methods), Pt-Co/Hazen/APHA, CIE values, spectral data CIE values (standard selection), L*C*h colour space, Hunter L a b colour space, spectral data

28


Physical Properties Compositional Analysis

Economical Colour Measurement of Resins, Lacquers, Fatty Acids, Lecithins, Sunflower, Linseed Oil, etc Digital, portable with push-button display Gardner colour (ASTM D 1544, ASTM D 6166, AOCS Td 1a, MS 817 Part 10) ▀▀ On-screen warning system of: o Within Tolerance = Green o Outside Tolerance = Red o On Border of Tolerance = Amber ▀▀ Provides immediate information on the sample ▀▀ Single number, one dimensional colour scale for grading the colour of similarly coloured liquids ▀▀ Validation liquid & glass standard included ▀▀ ▀▀

Optical Analysers

EC 2000 Gardner

Beers, Malts & Caramels

Separation Science

Sugar Solutions, Syrups & Honey

Fermentation

Scales include: ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

CIE L*a*b Delta E* Colour Difference International Fruit Juice Union (IFU) Colour Maple Syrup Spectral Data Transmittance

▀▀ ▀▀ ▀▀

▀▀

▀▀ ▀▀ ▀▀

Alpha Amylase in Malt ASBC Colour Series 52 (Brown) Scale

Food & Beverages

▀▀ ▀▀

Whisky EBC (European Brewing Convention)

Edible Oils & Fats

Laboratory Essentials

xyY Chromaticity Co-Ordinates XYZ Tristimulus Values ICUMSA Colour Index (ICUMSA GS1-7, ICUMSA GS2/3-9) Honey Colour (Pfund Equivalents)

Vacuum Pump Solutions

▀▀

Scales include:

Trade Waste

▀▀ ▀▀ ▀▀ ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Lovibond® RYBN Colour Maple Syrup Milk Quality Resazurin Test Optical Density (Absorbance) Spectral Data Transmittance Whiteness Index (ASTM E 313) xyY Chromaticity CoOrdinates XYZ Tristimulus Values Yellowness Index (ASTM E 313) Whisky ICUMSA Colour Index (GS1-7, GS2/3-9)

▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

AOCS-Tintometer® Colour Beta Carotene (BS 684 Section 2.20) Chlorophyll (AOCS Cc13d-55) CIE L*a*b Delta E* Colour Difference Dichromate Colour Index (DGF C-IV 4d discontinued) FAC Colour (AOCS Cc13a-43) Gardner Colour Kreis Value (Rancidity in Fats)

▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Lovibond® RYBN Colour Optical Density (Absorbance) Platinum-Cobalt/Hazen/ APHA Colour (ASTM D 1209) xyY Chromaticity CoOrdinates XYZ Tristimulus Values Yellowness Index (ASTM E 313)

Configuration Guides

▀▀

▀▀

Personal Protection

▀▀

Alpha Amylase Activity in Liquid Egg Alpha Amylase in Malt AOCS-Tintometer® Colour Beta Carotene (BS 684 Section 2.20) Chlorophyll (AOCS Cc13d-55) CIE 94 CIE L* u* v* Colour Space CIE L*a*b CIELAB (L*C*h) CMC Tolerancing Delta E* Colour Difference Hunter Lab International Fruit Juice Union (IFU) Colour

Scales include:

Condition Monitoring

Scales include:

29

Australia - Free Call: 1800 251 799


Refractometers

(refer Selection Guide on page 84 to personalise your needs) ▀▀ ▀▀ ▀▀ ▀▀

Compact (fits in your pocket), rugged & lightweight (weighs only 100 g) 3 second measurement, easy calibration & auto temperature compensation ‘External Light Interference’ function helps eliminate errors from stray light sources Simply choose the measurement scale you need - examples include: Baume Condiment Fructose Hydrogen Peroxide KMW Mannitol Phosphoric Acid Salt Concentration Sodium Tartrate

PAL-2

Bittern Dextran Glucose Inulin Lactose Methyl Alcohol Plato Sodium Bicarbonate Soy Milk Concentration

Brix Ethyl Alcohol Glycerine Inverted Sugar Magnesium Sulphate Moisture Potassium Phosphate Sodium Chloride T.A. 1990/1971

Citric Acid Formic Acid Honey Moisture Lactose Maltose Non-Fat Milk Solids Refractive Index Sodium Hydroxide … and more!

Food

Grapes

Dairy

Confectionary

Salt

Soups & Honey

Sugars

Wine & Beer

Hand-Held ‘Pen’ Style Refractometers ▀▀ ▀▀ ▀▀

▀▀ ▀▀ ▀▀

Easy-to-read, easy-to-hold, smooth sampling, high contrast scale (with large numbers) Spoon-shaped sample chamber for easier sampling Automatic Sample Distribution - prism housing allows sample to cover the prism without having to lift the day-light plate (allows fast & easy measurements) Easy-to-clean (simply wash under water) Automatic temperature compensation Extensive range of models & applications

Automatic Digital Refractometer Accurate & functional User scales can be created ▀▀ Intuitive touch screen technology - makes navigation & selection a breeze ▀▀ USB flash drive & self-diagnosis capability ▀▀ Automatic temperature adjustment ▀▀ Measurement scales (range/accuracy) o Refractive Index (nD): 1.32422 to 1.58000 / ±0.0004 o Brix: 0.00 to 100.00% / ±0.03% ▀▀ ▀▀

RX-5000i

RX-5000i

www.johnmorrisgroup.com

30


Physical Properties

Refractometers - In-Line ▀▀

Can be incorporated in piping of manufacturing plants, liquid mixing devices & washing apparatuses Suitable for the control of mixing, concentration, fermentation & control of the concentration of water-based or alkali-based detergent, etc

General Purpose

Compositional Analysis

▀▀

Low Concentration Samples Optical Analysers

▀▀

Resolution

▀▀

Ideal for precision measurement of low concentration samples as well as fruit juices & other beverages The detection section is able to withstand temperatures between -30 to 165°C (during SIP/CIP) Refractive Index (nD): 1.32069 to 1.36500 Brix: 0.000 to 20.000% Refractive Index (nD): 0.00001 Brix: 0.001% Refractive Index (nD): ±0.00001 (1.32069 to 1.33681) Brix: ±0.007% (0.000 to 2.000%)

Laboratory Essentials

NIR - In-Line

Vacuum Pump Solutions

Accuracy

Refractive Index (nD): 1.32000 to 1.55700 Brix: 0.00 to 100.00% Refractive Index (nD): 0.0001 or 0.00001 Brix: 0.1 or 0.01% (by selection) Refractive Index: ±0.00010 Brix: ±0.05%

▀▀

Fermentation

Measurement Range

PRM-2000α

Two-piece construction: detection section & operation display section Continuously monitor water content & mixing ratio with successive measurements of refractive index, Brix or concentration

Separation Science

PRM-100α ▀▀

Real-Time Process Control Monitoring key parameters such as moisture, fat or protein to correct deviations Provide continuous & accurate measurements within seconds ▀▀ Display key parameters in the existing process control system: o Report generation & auditing function for instant documentation: o Calibration function for effortless method optimization o Reference sample collection by optional bypass sampler ▀▀ Average payback period less than 1 year ▀▀ Eliminates extensive in-house calibrations or purchase of calibration data bases ▀▀ Straight forward integration to process control systems ▀▀ Ingress protected (IP65, IP66k) & ATEX certified (gas & dust) ▀▀ ▀▀

Trade Waste Condition Monitoring

NIR-Online Process Analyzer

Control Your Entire Process - Economically ▀▀ ▀▀ ▀▀ ▀▀

▀▀ ▀▀

31

NIR-Online Multipoint System

Australia - Free Call: 1800 251 799

Configuration Guides

▀▀

Continuous monitoring of moisture, protein, fat, ash, starch, fiber or residual oil Control of entire processes with up to 9 multipoint heads sharing one multipoint sensor Reduces costly optical fibers due to daisy-chain connection of Multipoint heads Time-saving automated report generation & auditing function for instant documentation Eliminates extensive in-house calibrations or purchase of calibration data bases Immediate process corrections minimize waste and re-work Robust design for harsh conditions (eg vibrations, extreme temperatures, wind or humidity) Ingress protected (IP65, IP66k) & ATEX certified (gas & dust)

Personal Protection

▀▀


Polarimeters - Sugar Analysis High Performance Automatic Polarimeter/Saccharimeter Measures samples at both 589 nm & 882 nm (by changing optical units) ▀▀ Measurement stability in 12 seconds (4 seconds in high-speed mode) ▀▀ Repeatability of ±0.003°; Angle of Rotation ±0.0090°Z ▀▀ Up to 999 automatic consecutive measurements followed by average value display ▀▀ Connectivity to RX Digital Refractometers for automatic purity measurement ▀▀ FDA 21 CFR Part 11 (software included) & ICUMSA compliant ▀▀ Measurement readings: o User Scale o Angle of Rotation o Angle of Rotation of Quartz Plate o International Sugar Scale o Temperature o Specific Optical Rotation o Purity o Concentration ▀▀ ▀▀

SAC-i 589/882

Refractometer + Polarimeter … All-In-One! ▀▀ ▀▀ ▀▀ ▀▀

Purity, International Sugar Scale, Specific Rotation & Concentration are automatically calculated from the measured refractive index & angle of rotation Simple operation & only requires 3 mL sample 12 second measurement time 589 nm measurement wavelength

RePo-1

Measurement Scales

Angle of Rotation

Brix

Int’l Sugar Scale

Temperature

Measurement Range

-5° to +5°

0 to 85%

-130° to +130° Z

+15° to +40° C

0.01°

0.1%

0.1° Z

0.1° C

±0.1° (@ 20°C)

±0.2%

±3° Z

±1°C

Resolution Accuracy

Titrators Rugged Coulometric Karl Fischer Titrator ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Determines water contents of liquids, gases & solids 10 user programmable methods 1ppm/100% water Results in ppm, mg/kg, % & μg water Conforms to ASTM & ISO standards Small footprint & portable Incorporates software, printer & battery Applications include biological, pharmaceutical, beverages, dairy & meat products, honey/sugars, cosmetics, animal feed, etc

Aquamax KF Plus

Electronic Piston Burette ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Schott 500

www.johnmorrisgroup.com

Ideal for manual titrations, accurate dosing of small & large volumes plus the preparation of solutions Intelligent exchangeable dosing modules Includes pre-programmed standard methods & 15 user-defined methods Maximum dosing speed of 100 mL/minute Reagent data stored in intelligent exchangeable modules Connection for printer & an analytical balances Complete remote control via RS232 or USB interface Includes 20 mL glass cylinder exchange module, manual mouse controller, magnetic stirrer, titration stand rod & titration clamp

32


Physical Properties Compositional Analysis

Spectrophotometers Visible Spectrum Standard Pathlength

UV/Visible Spectrum

4 nm Bandwidth

5 nm Bandwidth

4 nm Bandwidth

Optical Analysers

Visible Spectrum Long Pathlength

▀▀ ▀▀ ▀▀

▀▀

Store up to 200 test methods Software-driven DNA/RNA/ Protein/Kinetics analysis Large LED display 10 nm

50 mm

(expandable to 100 mm with optional holder)

325 to 1,000 nm

325 to 1,000 nm

200 to 1,000 nm

<0.5% T at 340 & 400 nm

<0.5% T at 340 & 400 nm

<0.3% T at 340 & 400 nm

RS-232/USB

RS-232/USB

RS-232/USB

Output

Vacuum Pump Solutions

100 mm

Wavelength Range Stray Light

▀▀

Raman Spectroscopy

▀▀

▀▀

▀▀

▀▀ ▀▀

Condition Monitoring

▀▀

Non-destructive identification & verification of materials such as APIs, excipients, intermediates & finished products with just 1 unit Intuitive software can be used by non-technical users to rapidly identify samples in the lab, warehouse, loading dock or field - helping to eliminate quarantine areas & expedite materials through the manufacturing lifecycle Non-contact analysis can be performed through transparent containers (plastic & glass containers) while maintaining the volume & integrity of the sample Fast & convenient transitions between sampling accessories for raw material identification through a variety of packaging Software allows for identification & verification, library & method development plus data storage/transfer as well as data export & report generation Excitation wavelength: 785 nm Spectral range: 176 cm-1 to 2,900 cm-1 Robust multi-variate algorithms guarantee accuracy when testing & identifying materials

Trade Waste

▀▀

Laboratory Essentials

Hand-Held Material Identification/Verification ▀▀

Fermentation

Pathlength (max)

▀▀

Separation Science

Narrow band width Economical & non-scanning Auto-adjust filters to ensure accuracy 4-position cuvette holders

▀▀

NanoRam

Accessories Point & Shoot Adaptor

Liquid Vial Holder Adaptor

Large Bottle Adaptor

Tablet Holder Adaptor

Immersion Probe

NR-RAA

NR-PCC

NR-PAS

NR-LVH

NR-BSA

NR-TAH

NR-IMP

33

Australia - Free Call: 1800 251 799

Configuration Guides

Polystyrene Calibration Cap

Personal Protection

Right Angle Adaptor


Laser Particle Sizer Measure the particle size distribution of solids & suspensions - measuring range from 0.01 to 2,100 μm ▀▀ Intelligent modular design with different sample types: Falling Chute: dry measurement without dispersion or compressed air Autoloader: 26 positions for 40 mL standard containers Small Volume (Automatic): most dispersion liquids can be used, automatic rinsing - thanks to strong ultrasonic power Small Volume (Manual): ideal for organic solvents, easy rinse/clean between samples Dry Dispersion: efficient degradation of agglomerates, auto dispersion pressure adjustment, integrated sample feeding Wet Dispersion: adjustable ultrasonic-intensity, automatic rinsing cycle ▀▀

Analysette 22 NanoTec

In-Line Particle Characterisation Characterise Particles Of Different Material In Real Time ▀▀

▀▀ ▀▀ ▀▀

▀▀

Provide particle size distributions & specific values & transmit to process control system via standard interfaces - for instance: Number density distribution (q0) Cumulative number distribution (Q0) Volume distribution (Q3) Various averaged diameters (d1,0, d3,2, d4,3, etc) Percentiles (dv10, dv50, dv90, etc)

Measurements for liquids & gases Results & quality are easily verifiable Measuring capability of 1 to 10,000 µm - probe images, bubbles, droplets, cells, yeast, grains, etc Software can recognize different particles at once & pinpoint irregular particles in a system

Sopat-MM

Measuring Range (microns) Field of View Probe Length Probe Diameter Temperature Range Focussing

Sopat-VR/VI

InView

0.9 to 90; 1 to 170

1.5 to 280; 3 to 350;

260 to 26000

0.295 or 0.385 mm 270 mm 24.5 mm -10°C to +250°C Manual

9 to 1200; 19.5 to 2600; 70 to 9300 0.64 to 21 mm 320 to 2000 12 or 20 mm -15°C to +450°C Automatic

60 mm 215 mm 130 mm 0°C to +50°C Manual

Image Analysis Example - Ice Cream Probability Density Function of Number

Probability Density Function of Volume

PDF q3[µm ^ -1]

Image Recognisation Results

PDF q0[µm ^ -1]

Original Image

Image After Filtering (homogenised illumination)

Particle Diameter dp [µm]

www.johnmorrisgroup.com

34

Particle Diameter dp [µm]


Physical Properties

Precision Sieve Shaker ▀▀ ▀▀ ▀▀ ▀▀

Compositional Analysis

Ideal for sieving sample quantities up to 2 kg & measurement ranges from 5 μm to 63 mm Suited for quality control (ISO 9001 & DIN 66165 compliant) with user-friendly operation & low-noise Particle size analysis of solids & suspensions of all kinds through dry or wet sieving Programme selection for storing up to 9 individual sieve programmes Can be transformed for grinding & homogenising small sample quantities (filling volume 1 to 10 mL, feed particle size <5 mm)

▀▀

High Speed Rotor Mill ▀▀

▀▀ ▀▀ ▀▀ ▀▀

Fermentation

PULVERISETTE 14 classic line

Vibratory Feeder ▀▀

▀▀ ▀▀ ▀▀

LABORETTE 24

▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Laboratory Essentials

Single Position Ball Mill

Vacuum Pump Solutions

Ideal for automatic, uniform feeding of free-flowing materials into sample dividers, mills or mixers The vibration conveys the sample material out of the funnel over the V-shaped stainless steel channel into the respective equipment Vibration amplitude is precisely controlled - for absolute uniform feed of even the smallest quantities Ideal for material feed between 1g/min to 1,500 g/min V & U shaped channels available

▀▀

Separation Science

▀▀

Fast comminution of soft to medium-hard, brittle & fibrous materials as well as temperature-sensitive samples Automatic speed compensation ensures an ideal adaptation of the grinding to the specific comminution behaviour of the sample. Variable speed settings between 6,000 & 20,000 rpm Max. feed size 10 mm with max. throughput 5 L/h Final fineness d50 <40 μm, sieve rings 0.08 to 6 mm Ideal for sample quantities <10 mL

Optical Analysers

ANALYSETTE 3 PRO

Single grinding bowl with easily adjustable imbalance compensation Suitable for hard, medium-hard, soft, brittle, tough & moist materials Safe tensioning of the bowls with the Safe-Lock-System Max. feed size: 10 mm (depends on material); Max. sample quantity: 225 mL Final fineness: <1 µm (depends on material) Main disc speed: 100 to 650 rpm

Trade Waste

PULVERISETTE 6 classic line

Universal Cutting Mill ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Easy cleaning exchangeable parts – no tools required Disk milling or V-rotor For soft to brittle, dry grinding materials as well as fibrous materials & plastics Max. feed size: 70 x 80 mm (depends on material) Max. throughput quantity: 60 L/h (depends on material & sieve size) Final fineness: 0.20 to 6 mm (depends on sieve insert) Rotor speed: 2,800 to 3,400 rpm

Condition Monitoring

▀▀

Accessories We provide a complete range of grinding bowls/balls including Agate, Zirconium Oxide, Stainless Steel, Hardened Steel, PTFE, Sintered Corundum, Hardmetal Tungsten Carbide, Tempered Steel

35

Australia - Free Call: 1800 251 799

Configuration Guides

In addition, we offer a large selection of mortars, sieve inserts/ cassettes, crushing jaws, etc

Personal Protection

PULVERISETTE 19


Milling, Grinding & Cutting Guide Very Suitable

Pulverisette 0 (Vibratory Micro Mill) Pulverisette 4 Classic Line (Vario Planetary Mill)

10 mm

450 mL

<1 µm

Pulverisette 5 Classic Line (Planetary Mill)

10 mm

4 X 225 mL

<1 µm

Pulverisette 6 Classic Line (Planetary Mono Mill)

10 mm

225 mL

<1 µm

Pulverisette 6 Premium Line

Impact Force

(Planetary Mill)

10 mm

450 mL

<0.1 µm

Pulverisette 7 Classic Line (Planetary Micro Mill)

5 mm

2 X 20 mL

<1 µm

Pulverisette 7 Premium Line (Planetary Micro Mill)

5 mm

70 mL

<0.1 µm

Pulverisette 9 (Vibrating Cup Mill)

12 mm

250 mL

10 to 20 µm

Pulverisette 14 Classic Line (Variable Speed Rotor Mill)

10 mm

5 L/h

0.08 to 6 mm

Pulverisette 14 Premium Line (Variable Speed Rotor)

15 mm

15 L/h

0.8 to 6 mm

Pulverisette 16 (Cross Beater Mill)

25 mm

80 L/h

0.12 to 10 mm

Pulverisette 23 (Mini Mill)

6 mm

5 mL

5 µm

www.johnmorrisgroup.com

36

Moist

10 µm

Temp Sensitive

10 mL

Fibrous

5 mm

Not Suitable

Material Type Suitability

Tough

Final Fineness

Brittle

Max Capacity

Soft

Max Feed Size

Medium-Hard

Model

Hard - Brittle

Working Principle

Suitable


Physical Properties

(Mortar Grinder)

Pulverisette 15 (Cutting Mill)

Pulverisette 19

Cutting Mill

(Universal Cutting Mill)

Pulverisette 25 (Power Cutting Mill)

120 X 85 mm

85 L/h

1 to 10 mm

Pulverisette 13 Classic Line

20 mm

150 kg/h

0.1 to 12 mm

20 mm

150 kg/h

0.5 to 12 mm

200 kg/h

1 to 15 mm

250 kg/h

0.3 to 15 mm

(Disk Mill)

Shearing Force

Pulverisette 13 Premium Line (Disk Mill)

Pulverisette 1 Classic Line

95 X 95 mm

(Jaw Crusher)

Pressure

Pulverisette 1 Premium Line (Jaw Crusher)

95 X 95 mm

Moist

0.2 to 6 mm

Temp Sensitive

60 L/h

Fibrous

70 X 80 mm

Tough

0.25 to 20 mm

Brittle

50 L/h

Soft

70 X 70 mm

Trade Waste

10 to 20 Âľm

Laboratory Essentials

190 mL

Pulverisette 2

Friction

Vacuum Pump Solutions

8 mm

Material Type Suitability

Fermentation

Final Fineness

Separation Science

Max Capacity

Not Suitable

Sample Type Examples

37

Australia - Free Call: 1800 251 799

Configuration Guides

John Morris Group also supplies particle size analysis instruments (sieving, laser diffraction & dynamic image analysis)

Personal Protection

Clinker, quartz, rock, bauxite, ceramics, carborundum Glass, cement, calcite, coal, ash, sewage sludge, soil, fertilisers, feed, catalysts, tablets Grain, gypsum, salts, talc, animal feed, graphite, leaves, grass, pigments, spices, mica Alloys, ceramics, salts, silicon carbide/nitride, coke, coal Leather, hides, rubber Wool, resins, wood, cellulose, paper, plant roots Thermoplastics, pharmaceuticals Soil, grass, hay, leaves

Condition Monitoring

German quality with a 2 year warranty

Hard - Brittle: Medium - Hard: Soft: Brittle: Tough: Fibrous: Temp Sensitive: Moist:

Optical Analysers

Max Feed Size

Medium-Hard

Model

Hard - Brittle

Working Principle

Suitable

Compositional Analysis

Very Suitable


SEPARATION SCIENCE Chromatography (refer Selection Guide on page 85 to personalise your needs)

Simplify Solid Phase Extraction ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

For simple automation of manual solid phase extraction (SPE) methods Run the same method or different methods for up to 12 samples per run Controlled positive pressure sample & solvent flow rates for the best recoveries & precision Use virtually any commercially available, tabbed & tab-less 1, 3 or 6 mL cartridge Up to four fractions per sample can be collected or discarded Modular & scalable to match your laboratory workload A variety of solvents in any ratio can be mixed in-line for true SPE optimization Samples from one mL to one litre can be easily accommodated Automated filtering, concentration, clean-up, and buffer exchange Automated sample dilution prior to SPE Easy coordination with a variety of bar code readers to enter sample IDs into the software

SmartPrep® Automated Cartridge Extractor II

Purification of Organic Compounds ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

High efficiency separations at a pressure up to 50 bar Saves time by simultaneously monitoring four wavelengths Multi-signal monitoring for peak detection & fraction collection Suitable for all flash purification requirements Wide choice of corresponding flash cartridges & glass columns Detection over all UV-Vis range (optional ELSD) Sample injection scalable from a few milligrams up to hundred grams Elution flow rate up to 250 mL/min Purification scale-up performance on large cartridges (up to 1600 g) or glass columns

Sepacore® X50

All-in-One Purification System ▀▀ ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Accelerated purification Flash chromatography separation & subsequent preparative HPLC purification of all relevant fractions on the same system Save time when optimizing the separation of complex samples using up to 4 solvents Detect all compounds at once with DAD & optional ELSD Full separation optimization capabilities with quaternary gradient functionality (HPLC pump technology) High efficiency preparative HPLC columns (10 or 15 µm) can be run at a pressure of up to 100 bar (1450 psi) Perform prep HPLC as easily as flash chromatography Intuitive graphical user interface designed for purification applications Easy connection of flash cartridges, glass columns or preparative HPLC columns PrepChrom C-700

www.johnmorrisgroup.com

38


Physical Properties

Ideal for Using Both Flash & Preparative HPLC ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

▀▀

Optical Analysers

▀▀

Single click software switches between flash & preparative HPLC Use both flash cartridges & preparative HPLC columns Up to 200 mL/minutes in both flash & HPLC modes Up to 1700 psi (120 bar) in preparative mode 3 channel variable UV-Vis & ELS detection Detects both chromophores & non-chromophores Intuitive, simple software interface with large 30.5 cm touch-screen display Choose speed &/or purity

Compositional Analysis

▀▀

Next Generation Flash System ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Maximizes recoveries by directing only 30 µL/min or less of your sample to ELSD Up to 200 mL/minute & 200 psi (14 bar) Quickly modify run parameters on a large 30.5 cm touch-screen Edit gradients in real time, using click & drag or table Detect chromophores, non-chromophores & visible sample components from mg to kg quantities Easily switch between normal phase & reversed-phase applications

Reveleris X2

Vacuum Pump Solutions

▀▀

Synchronized detection & fraction collection from up to 4 detector signals (ELSD/UV/Vis) Detects the widest range of compounds

Fermentation

▀▀

Separation Science

Reveleris® PREP

Flexible Flash Purification System ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Trade Waste

▀▀

Quickly modify run parameters on 30.5 cm single touch-screen Edit gradients in real time - using click & drag or table Simple fraction collection due to automatic slope detection Selectable detector sensitivity for various sample types & concentrations Purify complex samples from discovery through process R&D Easily switch between normal phase & reversed-phase applications Prevention of running out of solvent due to solvent level sensors

Laboratory Essentials

▀▀

Reveleris® X2-UV

Cartridges & Columns

Condition Monitoring

▀▀ ▀▀

▀▀ ▀▀

Choice of luer slip or lock outlet connection A smaller particle size increases resolution & higher particle size distribution & minimal fines help keep back-pressures low

39

Glass Columns

Sample load up to 370 g Any separation scale up (with choice of sorbent material) ▀▀ Broad range of sizes: o Internal Diameter: 15 to 100 mm o Length: 100 to 920 mm ▀▀ ▀▀

Australia - Free Call: 1800 251 799

Configuration Guides

▀▀

Superior resolution with ultrapure 40 μm silica Silica & multiple bonded phases available Standard 60 Å or wide pore silica available

GraceResolv™ Flash Cartridges

Personal Protection

Reveleris® Flash Cartriges


Nitrogen Blowdown & Concentration Automated Extraction System ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

SPE-DEX® 4790

▀▀

Programmable, multi-purpose SPE system - processes aqueous samples directly from their original containers Uses less solvent & creates less waste - controlling costs Accommodates 20 mL to 4 L samples for all sensitivity needs EZ Flow disk holder is designed to collect particulates before the SPE disk - maintaining flow Pre-filters available to keep the sample flowing A variety of solvents can be used including dichloromethane, methanol, hexane, etc Unique web-based controller software included

Oil & Grease Extractor (Hexane-Extractable Material) ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Fully compliant with regulatory methods such as US EPA method 1664B, ISO 11349 & Standard Methods 5520G Uses the original sample bottle to dispense the sample & automatically rinses it Simple to operate with touch-screen controller & on-board methods Disks & bottles of various sizes accommodated for best match with lab needs Handles all types of samples with reliable operation Bench-top design, frees up hood space SPE-DEX 3100

Automated Evaporation/Concentration System ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

XcelVap®

▀▀

Evaporation is accomplished by combining consistent heat, controlled nitrogen flow & active venting of the solvent vapours Less time required to prepare reproducible extracts for chromatography analysis (GC/MS, LC/MS, GC, LC) Automated pressure profiling for optimum speed with no splattering or cross contamination Nozzles can be individually changed/reconfigured for different racks by the user Nitrogen blow-down evaporation of up to 54 sample extracts - ranging in size <1 mL to 200 mL Easy water bath management with water level sensor & front draining for best performance Accommodates many popular sample tubes providing flexibility for multiple applications

Automated Solvent Evaporation System ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Low temperature heating system provides consistent & gentle heating of all samples to prevent the loss of volatile analytes Gentle airflow of vacuum accelerates the evaporation of n-hexane from the samples Reduced exposure to hazardous solvents Compliant with US EPA 1664, ISO 11349:2010 & Standard Methods 5520 Can also be used to evaporate solvents from extracted soil hydrocarbons & fats from foods The evaporation temperature is adjustable from 20°C to 60°C - allowing flexibility for a range of solvents Reduces evaporation process time by 25% to 50%

Speed-Vap® IV

Automated Drying & Concentration System ▀▀

▀▀

▀▀ ▀▀

DryVap®

▀▀ ▀▀

www.johnmorrisgroup.com

Combines the drying, evaporation & concentration of organic extracts into 1 automated step prior to GC & GC/MS analysis in <30 minutes Emulates traditional Kuderna Danish (KD) method - system uses a unique combination of vacuum, heat & nitrogen sparge gas to rapidly evaporate & gently concentrate extracts down to a precise desired volume Automatic end-point detection & shut-off 6 samples simultaneously or individually - with 4 selectable solvent times The system incorporates in-line sample drying Every parameter in the system is optimized & saved as a method with the Control Software option

40


Physical Properties

Rotational Vacuum Concentration (RVC) Mid-Sized

Maxi

Maxi with Infrared Heating

2-18 CDplus

2-18 HCI CDplus

2-25 CDplus

2-33 CDplus

2-33 IR CDplus

Optical Analysers

Mini HCI Acid Resistant

Compositional Analysis

Mini

72 x 1.5/2.2 mL 6 x 50 mL

Rotor Speed

108 x 1.5/2.2 mL 6 x 1,000 mL

1,500 rpm

1,550 rpm

+30° to +60°C

Volume

0.2 to 50 mL

1,750 rpm

0.2 to 100 mL

Chemical Resistant (2 mbar - 2 m3/hour) 1.0 to 500 mL

Rotor Bowl

Parallel Evaporation

Laboratory Essentials

Rotary Evaporation

IR Lamps

Vacuum Pump Solutions

Heating Method

216 x 1.5/2.2 mL 4 x 500 mL 12 x microtiter plates 4 x deep wells

+30° to +80°C

Chemical Resistant (7 mbar - 2 m3/hour)

Vacuum Pump

216 x 1.5/2.2 mL 12 x 100 mL 12 x microtiter plates 4 x deep wells

Fermentation

Temperature Range

48 x 1.5/2.2 mL 6 x 50 mL

Separation Science

Capacity

Syncore® Analyst R-12

Trade Waste Condition Monitoring

Heat Control

20° to 180°C Analogue or Digital

Economical High Quality Concentration ▀▀ ▀▀

Lift Type

Cooling Surface (cm2)

20 to 285 1,460

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

41

Australia - Free Call: 1800 251 799

Configuration Guides

Speed (rpm)

Manual or Motor

Fast concentration of up to 12 samples in parallel No need for nitrogen (saves operational cost) Small foot print saves expensive lab space Eliminate the risk of cross contamination Integrated solid phase extraction (SPE) eliminates contamination risks Uses fast parallel vortex evaporation technology to save time Concentrate to a pre-defined residual volume allows unattended workup

Personal Protection

Bath Temperature


Freeze Drying Selection Guide All instruments are modular in design allowing added features to be easily included Routine Lab

Ice Condenser Capacity

Aqueous

2 kg

Alpha 1-2 72 caps LDplus

4 kg

Alpha 1-4 LDplus

Advanced Applications

Pilot

Production Solvent

Solvent

Aqueous

Solvent

Solvent

Alpha 2-4 LDplus

Alpha 1-4 LSCplus

Alpha 2-4 LSCplus

Epsilon 1 & 2-4 LSCplus Epsilon 2-6 LSCplus

6 kg Beta 1-8 LDplus

8 kg

Beta 2-8 LDplus

Beta 1-8 LSCplus

Beta 2-8 LSCplus Epsilon 2-10 LSCplus

10 kg 16 kg

Gamma 1-16 LSCplus

24 kg

Delta 1-24 LSCplus

Gamma 2-16 LSCplus Delta 2-24 LSCplus

20 to >1,000 kg

Customised

Routine Lab Applications Entry Level Systems (day-to-day freeze drying applications)

Ice Condenser

Product Shelves

Capacity

2.5 to 8 kg

Performance

2 to 6 kg/hour

Temp

Aqueous

-55°C

Solvent

-85°C

Drying Outside Ice Chamber

3 to 5 Shelves ø 200 to 360 mm ≈920 cm2 to 0.5 m2

Drying in Injection Vials with Stoppering

2 to 4 Shelves ø 200 to 250 mm ≈557cm2 to 0.18m2

Drying in Round Bottom Flasks

Alpha 1-4

Alpha 2-4 LDplus

Beta 1-8 LDplus

Base unit + 3 shelves & 8 ports

Base unit + stoppering device, 2 shelves & 8 ports

Base unit + 5 shelves

8 to 24 Pieces

Base unit + 8 ports

Base unit +ampoule manifold

Base unit + 3 shelves & 24 ports

Did You Know You Don’t Need a -105°C Ice Condenser! As all Christ ice condenser coils are internal, the vapour temp is condensed at -85°C. Instruments with external coils have a temp of -105°C outside but -85°C inside the chamber. Both produce the same condenser temp performance & solvent trapping effectiveness

www.johnmorrisgroup.com

42


Physical Properties

Automatic Beer Bitterness Determination

Compositional Analysis

Master Your IBU Values Samples run every 13 minutes - multiple samples can be processed sequentially Alternative to manual extraction or expensive chromatography methods ▀▀ Used in process (at-line) for adjusting the brewing process or as final QC/QA ▀▀ Bitterness as sum parameter: iso α-acids + other components ▀▀ Bitterness displayed as IBU or EBU units ▀▀ 0 to 40 IBU measuring range ▀▀ Precision - better than 2.5% full scale ▀▀ No sample pre-treatment necessary (except degassing) ▀▀ Smart features include auto-cleaning & auto-calibration ▀▀ Up to 8 sampling points possible ▀▀ Analysis method: Determination of International Bitterness Units conform with ASBC MOA/Beer bitterness & EBC Analytica method 9.8 ▀▀ ▀▀

Optical Analysers Separation Science

Operation Principle Present a degassed sample to the analyzer Absorbance of pure iso-octane is measured Sample is acidified & iso-octane is added in 1:2 ratio Extraction is promoted by forced aeration Transfer for absorbance measurement at 275 nm Calculation of IBU & reporting of results Cleaning cycle prevents cross-contamination

Fermentation

1. 2. 3. 4. 5. 6. 7.

Vacuum Pump Solutions

Up to 8 samples

Anaerobic Digester Analyzer ▀▀ ▀▀

▀▀ ▀▀

Trade Waste

▀▀

On-line monitoring of critical process parameters & process efficiency on anaerobic digestion On-line, automatic system for measuring total volatile fatty acids (VFA), bicarbonate, alkalinity (total & partial) & pH (ammonia optional) in one single run Results in 10 to 15 minutes - allow true process monitoring, protection & optimization Dual range possibility for influent/effluent analysis Multiplexing up to 8 sampling points possible

Laboratory Essentials

IBULyzer

Schematic of Typical Operation Condition Monitoring

Biogas Effluent Substrate Fluid Zone

Samples

Personal Protection

Sludge Zone

Sampling Filtration or Extraction

AnaSense®

43

Australia - Free Call: 1800 251 799

Configuration Guides

Mixing Zone


FERMENTATION Cultivation Systems Single-Use Bioreactor System ▀▀ ▀▀

▀▀

▀▀

Convert your existing benchtop glass bioreactor to a single-use bioreactor in seconds! Simply remove your existing headplate & place the pre-assembled & irradiated BIOne System into the glass vessel - bioreactor liner will mold to & mimic your existing glass system allowing you to continue using existing cabinet, probes, motor, heating jacket & recipes. Contains 4 probe ports including a non-invasive DO sensor, non-invasive pH sensor & two universal sensor ports which can be utilised for 12 mm CO2, DO, pH, biomass, glucose, etc Compatible with most manufacturers’ glass vessels from 3 L to 7 L BIOne

Glass Autoclavable Bioreactors ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

▀▀

Volumes from 1.25 L to 23.4 L (interchangeable modules) Stirrer speeds from 50 rpm up to 2,000 rpm No welded parts in the bioreactor top-plate Simple set-up & easy to handle Optional high torque magnetically coupled agitator All metal parts are constructed of stainless steel 316L Electropolished finish of product contact stainless steel parts Glass dished bottom vessels are made of borosilicate glass to guarantee resistance to thermal shock, excellent corrosion resistance, smooth & non-porous surface for easy cleaning as well as transparency for visual inspection Glass bioreactor vessels can be used up to 0.5 bar (7.5 psig) of overpressure

Glass Autoclavable Bioreactors

Steam-In-Place Bioreactor Systems ▀▀ ▀▀

▀▀

▀▀ ▀▀ ▀▀

▀▀

Easy to clean mirror polished external finish Electropolished finish of all parts in contact with the culture (Ra <0.4 μm) allow efficient clean-in-place Modular design permits easy adaptation to changing process demands Magnetically coupled agitator for peace of mind cGMP compliant design simplifies validation Open frame construction gives easy access for maintenance & operation Choose from 7 L to 30 L systems

Steam-In-Place Bioreactor Systems

www.johnmorrisgroup.com

44


Physical Properties

Real Time O2 or CO2 Measurement ▀▀ ▀▀ ▀▀

BCP-O2 Sensor

Optical Analysers

▀▀

Measuring range from 0.1 to 50 Volume % Robust, compact & exact calibration Easily integrated in existing off-gas lines Choice of robust POM version with aluminum housing (IP-65) or compact version with a PA plastics housing

Compositional Analysis

CO2 & O2 Sensors

PA Housing

Separation Science

CO2 & O2 Measurement Concentration range: O2 Sensor: 0.1 to 100 Volume % (Galvanic cell) CO2 Sensor: 0 to 25 Volume % (infrared, dual wavelength) ▀▀ Signals can be exported as analog (4-20 mA each for both signals) or digital signals (RS485 Modbus, RS232, USB) ▀▀ Data logged using an optional web server ▀▀ No gas cooler, pumps or valves required ▀▀ Also measures pressure & humidity in the off gas of the bioprocess (therefore not affected by either) ▀▀

Fermentation

Yeast Cell Counting ▀▀ ▀▀ ▀▀

Piston

Camera detecting emitted light Flow channel system containing immobilized acridine orange & DAPI

NucleoCounter® YC-100™

▀▀ ▀▀

▀▀ ▀▀ ▀▀

▀▀

UVP ColonyDoc-It Imaging Station

45

Australia - Free Call: 1800 251 799

Configuration Guides

▀▀

Personal Protection

▀▀

Accepts pour, spread & spiral plates & filters plates from 33 mm to 150 mm Versatile selection of darkfield light, epi & trans-illumination white light or epi blue light Lens 6 X optical zoom (4 X digital zoom) High resolution camera (15.1 megapixels, USB interface) Optional GFP filter to enable visualisation of GFP reporters Extensive software functions offer image enhancements, annotation & reporting tools plus distinguish positive & negative bacteria Identify colonies as small as 0.08 mm in diameter FDA compliant, with supporting GMP, GLP & CFR documentation

Condition Monitoring

Automated Colony Counting

Trade Waste

Most precise yeast counter Total cell count & viability of yeast cells in suspension Consists of a camera & integrated fluorescence microscope designed to detect signals from the fluorescent dye, propidium iodide (PI) bound to DNA - results represent either total or nonviable cell concentration

Dual fluorescent light (UV+green)

Laboratory Essentials

Calibrated measurement chamber

Vacuum Pump Solutions

BlueInOne Sensor


VACUUM PUMP SOLUTIONS Packaging, Production & Processing

SCREWLINE SP Series

DRYVAC DV Series

LEYVAC LV Series

RUVAC WAU 2001 FP

RUVAC WAU 1001 FP

RUVAC WAU 501 FP

RUVAC WAU 251 FP

SOGEVAC SV Hydro Range

SOGEVAC SV Oxygen Range

SOGEVAC SV 1200

SOGEVAC SV 630 B

SOGEVAC SV 470 B / 570 B(F)

SOGEVAC SV 300 FP

SOGEVAC SV 200 FP

SOGEVAC SV 105 FP

SOGEVAC SV 70 FP

SOGEVAC SV 45 FP

Applications

SOGEVAC SV 25 FP

Pumps

SOGEVAC SV 10 FP / 16 FP

(refer Selection Guide on page 86 to personalise your needs)

Vacuum Packaging Metal Can Sealing (coffee, powder milk) Thermoforming/ Rollstock Modified Atmosphere Packaging (without O2) Modified Atmosphere Packaging (with O2) Freeze Drying (fruits, spices, coffee) Vacuum Cooling Slaughterhouse Applications Stuffing/Mixing Tumbling Vacuum Cutting Vacuum Clipping

SOGEVAC SV 10 FP to SV 300 FP ▀▀ ▀▀

▀▀ ▀▀ ▀▀

High pumping speed/footprint ratio by compact design Maximum tightness & low complexity thanks to integrated functions & no external pipes Lowest noise level on the market Pump speed from 10 m3/h to 240 m3/h Based on proven Sogevac design with manual gas ballast & oil filter

www.johnmorrisgroup.com

SOGEVAC SV 470 B & SV 570 B ▀▀

▀▀ ▀▀ ▀▀ ▀▀

Very low rotational speed increases pump’s lifetime with extremely low noise level Reduced number of oil pipes Pump speed 400 m3/h & 470 m3/h Air or water-cooling & many motors & options available Adaptors for direct mounting of Roots blowers

46

SOGEVAC SV 630 B / 750 B ▀▀

▀▀ ▀▀ ▀▀ ▀▀

Very low rotational speed increases pump’s lifetime with extremely low noise level Reduced number of oil pipes Pump speed 640 m3/h & 755 m3/h Air or water-cooling & many motors & options available Adaptors for direct mounting of Roots blowers


Physical Properties Compositional Analysis

SOGEVAC SV 1200

▀▀ ▀▀ ▀▀

▀▀

▀▀ ▀▀

▀▀ ▀▀

▀▀

Suitable for packaging under modified atmosphere (M.A.P.) Hydrocarbon-free pump parts & inert PFPE oil filling for use in O2 applications High pumping speed down to ultimate pressure Operation of the pump at all pressures between 1000 mbar (750 Torr) & ultimate pressure is possible Integrated & effective separation of oil mist

▀▀

▀▀ ▀▀ ▀▀

Big gas ballast or two gas ballasts to increase pump water vapour tolerance Pump speed from 22 m3/h to 1,070 m3/h No oil filter or oil filter by-pass to avoid early clogging Stronger motor to handle high working pressure

Separation Science

▀▀

Very low rotational speed increases the lifetime of the pump and leads to noise level reduction Possible operation at any inlet pressure Pump speed 1,070 m3/h Air or water-cooling and many motors and options available Adaptors for direct mounting of Roots blowers up to 7,000 m3/h without additional frame Wide range of pump monitoring sensors available

SOGEVAC SV Hydro Range

Optical Analysers

▀▀

SOGEVAC SV Oxygen Range

Fermentation

▀▀ ▀▀

▀▀ ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Rugged vacuum pumps for rough applications & high process throughputs Simple vacuum performance upgrade with RUVAC Roots pumps Pumping speed 80 m3/h to 300 m3/h Hermetically sealed pump Low noise operation, low heat loss Direct connection of RUVAC Roots blowers via adapter

▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Rugged, dry compact vacuum solutions with smart monitoring & control system for food & packaging applications Pumping speed 450 m3/h to 1,200 m3/h Vertical or horizontal installation Integrated frequency converter for optimal process control Smart monitoring of major parameters Direct connection of RUVAC Roots blower via adapter

Trade Waste

▀▀

▀▀

DRYVAC DV Series

of vacuum pumps (turbomolecular, rotary vane, diaphragm, screw roots, etc) for all brands. SCREWLINE SP Series

▀▀ ▀▀ ▀▀

▀▀

Typical applications include thermoforming, tray sealing, Modified Atmosphere Packaging (with/without oxygen), tumbling, vacuum conveying Systems consist of oil sealed rotary vanes/dry screw pumps/roots blowers combination, buffer vessel, electrical cabinet with PLC controller, filtering & connecting components

47

Our areas of expertise include: ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Service Agreements Breakdown Service Technical & Training Support Extended Warranties Trade-In Services Testing & Commissioning Calibration & Verification

Australia - Free Call: 1800 251 799

Configuration Guides

▀▀

▀▀

Personal Protection

▀▀

Extremely robust for harshest food & packaging applications Pumping speed 250 m3/h to 630 m3/h Designed for demanding processes Air cooled Monitoring system Direct connection of RUVAC Roots pumps via adapter

Central Vacuum Stations

Condition Monitoring

John Morris Group services all types

▀▀

Laboratory Essentials

▀▀

Air-cooled line WAU FP with four blower sizes Motors of efficiency class IE 2 Pump speed from 253 m3/h to 2,050 m3/h Shaft seals & elastomer seals made of FPM (FKM)/Viton Combination of RUVAC Roots blowers with SOGEVAC forevacuum pumps increase pumping speed, improve ultimate pressure & shorten cycle times Vertical to horizontal flow conversion

LEYVAC LV Series

Vacuum Pump Solutions

RUVAC WAU 251 FP to 2001 FP


LAB ESSENTIALS Pipettes Extensive selection of mechanical, electric or motorised pipettes - contact us for details on our full range

Silicone Pipette Filler ▀▀ ▀▀ ▀▀ ▀▀

3 way valve Up to 50 mL capacity Provides greater chemical resilience than natural rubber Autoclavable

Pipette Filler #24805-20

Pipette for Problem Liquids - Viscous & Solvents ▀▀ ▀▀ ▀▀

Microman E

▀▀ ▀▀

100% protection against contamination (no air-to-liquid interface) Desired volume aspirated rapidly & accurately - no calibration required Volume securing button; Large selection of Capillary Pistons QuickSnap - tips fit like a normal pipette Choice of 6 models (volumes from 1 to 1,000 μL)

Pipette Up To 100 mL ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Precise & smooth dosing button control: Drop-by-drop, Gravity mode & Motorised speed Continuously adjustable speed (25 mL in 4 seconds) Large dosing button Firm fit for all standard glass & plastic pipettes Continuous operation for up to 8 hours

Macroman

Lowest Pipetting Force on the Market ▀▀ ▀▀ ▀▀

Pipetman G

▀▀

Lubricated piston assembly for easier pipetting Clip ejector for easy dismantling & greater tip fitting; Metal or plastic ejectors Qualifies for our free Lifetime Warranty program - visit our web site for full details Choice of 8 models (volumes from 0.2 µL to 10 mL)

Guaranteed ISO Specification on Standard & Repetitive Pipetting Fully motorised with lockable volume & adjustable speed piston Intuitive interface with 5 pipetting modes: standard, repetitive, mix, reverse & custom ▀▀ Plastic clip tip ejectors for easy dismantling & greater tip fitting ▀▀ Independent speeds for aspirating & dispensing for varying solution densities ▀▀ Choice of models: o Single Channel: Select from 8 options (volumes from 0.5 µL to 10 mL) o 8 & 12 Channel: Select from 6 options (volumes from 0.5 µL to 1.2 mL) ▀▀ ▀▀

Pipetman M - Single & Multi

John Morris Group also offers an extensive range of Pipette Starter Kits, accessories & spare parts plus we also service & calibrate all major pipette brands

www.johnmorrisgroup.com

48


Physical Properties Compositional Analysis

pH Meters Quality pH Meter with ISFET Probe - Ideal for Meats & Cheeses ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Optical Analysers

FieldScout pH 600

±0.01 accuracy with 0.005 resolution 500 data sets, IP65 rated Large backlit LCD colour screen Supports up to 5 point calibration Choice of glass-free probes (won’t shatter): Pin Point Tip or Blunt Tip

Economical pH Meter ▀▀ ▀▀ ▀▀

Oakton pH 700

▀▀

Separation Science

▀▀

Measures pH, mV, relative mV & temperature Space saving, economic & versatile Large easy-to-read LCD display Records 100 data sets Includes double-junction refillable glass pH electrode, ATC probe & stand

High Precision pH Meter ▀▀

▀▀ ▀▀ ▀▀

Measure pH, mV, relative mV & temperature Meets GLP requirements 0.001 pH resolution with ±0.002 pH accuracy Records 500 data sets Includes ATC probe, pH electrode & 600 mL of electrode fill solution

Fermentation

▀▀

Oakton pH 2700

▀▀ ▀▀

Vacuum Pump Solutions

pH Solution Pack Includes pH 4.01, 7.00, 10.01 buffers Plus electrode storage & cleaning solutions

Oakton pH Pack

▀▀ ▀▀ ▀▀

Plastic pH Indicator Strips

Immediate pH testing in brilliant, long lasting colours Clear plastic cases contain 100 dip sticks Direct-reading pH papers give a simple, single colour match for all pH values in distinct, bright colour separations

Trade Waste

Peracetic Acid Sanitizer Test Strips ▀▀ ▀▀

Sanitizer Test Strips

▀▀

Quick reliable test for the strength of PPA wash solutions Covers critical ranges for antimicrobial fruit & vegetable rinses 0 to 160 ppm 50 strips per vial/6 vials per case

Condition Monitoring

▀▀

Laboratory Essentials

pH Test Paper Strips

Food & Beverage Test Strips ▀▀

Test

Measurement Points

Tests per Pack

QAC

50, 100, 200 & 400 ppm

100

Chlorine (Sanitizer)

10, 50, 100 & 200 ppm

200

Iodine

12, 25, 50 & 100 ppm

200

Chlorine (High Range)

0, 50, 100, 250, 500 & 800 ppm

50

49

QAC Test Strips

Australia - Free Call: 1800 251 799

Configuration Guides

Chemically treated paper strips as a quick test for sanitizer strength Compare colour change to included chart for easy-to-read results

Personal Protection

▀▀


Balances Precision Balances

Entry Level Balance

EMB600-2

Simple & convenient 2-key operation Ideal for schools & universities Calibration

PFB1200-2

Capacity display – shows how much weighing range is still available Draft shield included

Moisture Analysis

PCB350-3

Freely programmable weighing unit (eg display direct in special units such as length of thread g/m, paper weight g/m2, etc) Draft shield included

MLS50-3C

Infrared moisture analyser with 100 memories & graphic display 400W halogen quartz glass heater

External

External

External

External

Weighing Range

600 g

1200 g

350 g

50 g

Readout

0.01 g

0.01 g

0.001 g

0.001 g

Analytical Balances

ALJ310-4A

ABT220-5DM

Weighing Table

AET200-4NM

Automatic internal Complete range of Automatic internal adjustment (in case temp adjustment (in case temp functions changes by >0.5°C) Hands-free functions – changes by >0.5°C) TARE, zeroing, printing Large glass draught shield Dual range balance Shock proof construction Innovative touchscreen with 3 sliding doors Calibration

YPS-03

Polished marble plate working surface Steel profile frame & height-adjustable feet

Internal

Internal

Internal

-

Weighing Range

310 g

82 g/220 g

220 g

-

Readout

0.1 mg

0.01 mg/0.1 mg

0.1 mg

-

PTFE 304 Stainless Steel Spatulas ▀▀

Spatulas

Choice of: o Tapered end to 6.3 mm - 21 mm in length (2 per pack) o Tapered end to 0.8 mm - 18.4 mm in length (2 per pack) o Square end - 18.4 mm in length (2 per pack)

Scoops

Scoops

Large selection of scoops including: ▀▀ Material: stainless steel, polypropylene, HDPE, PTFE, etc ▀▀ Shape: round, round bottom, rectangular, v-shaped, etc ▀▀ Sizes: huge selection to choose from ▀▀ Autoclavable

www.johnmorrisgroup.com

50


Physical Properties

Bench Scales

IP68 Rated & Stainless Steel

Compositional Analysis

Industrial Scales

Optical Analysers

FCB Series ▀▀

▀▀ ▀▀

▀▀ ▀▀ ▀▀

ATEX Balances

IP65 rating & special checkweighing display (colour changes depending on weight - too light/OK/ too heavy) 2nd display on rear of balance Weigh range: 1.5 to 30 kg Readout: 0.2 to 10 g

Ideal for robust industrial applications Bright backlight for easy reading of results Wall mount standard ESD drain to protect against electrostatic discharge Weigh range: 3 to 300 kg Readout: 1 to 100 g

▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Pre-Packaging Compliance

FXN Series ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

HACCP-compliant Suitable for use in harsh industrial applications Fast 2 second display Weighing with tolerance range (checkweighing) Weigh range: 15 to 30 kg Readout: 0.5 to 10 g

Fermentation

▀▀

▀▀

SXS Series

Separation Science

▀▀

Compact bench scale with simple concept of operation for use in industry and the catering trade Fast 2 second display Simple checkweigher in production or dispatch Weigh range: 3 to 30 kg Readout: 0.1 to 1 g

WTB Series

Counting Scales

Vacuum Pump Solutions

IEX EU Series

▀▀ ▀▀ ▀▀ ▀▀

Especially suitable for cosmetics & plastics Stainless steel weighing plate Load cells: Aluminium, silicone-coated, IP65 rated Weigh range: 6 to 150 kg Readout: 0.2 to 50 g

▀▀

▀▀ ▀▀ ▀▀

Price Computing Scales

CXB Series

Touchscreen with special software for testing in accordance with weights & measures regulations Capacity display, date/time & pre-tare functions Weigh range: 3 to 60 kg Readout: 0.5 to 10 g

Entry level 3 displays - total weight, piece weight, total count Change from counting to weighing mode at touch of button Weigh range: 3 to 30 kg Readout: 0.2 to 10 g

▀▀ ▀▀ ▀▀

▀▀ ▀▀

SMT Series ▀▀ ▀▀

▀▀ ▀▀

Innovative stocktaking scale with touchscreen Functions: capacity display, pre-tare, date/time, GLP printout, data transfer of stock, transfer of stocktake information Weigh range: 10 kg Readout: 1 g

Trade Waste

▀▀

FKTF Series

Laboratory Essentials

▀▀

Platform Scales

Floor Scales

Hanging Scales Condition Monitoring

RPB Series ▀▀ ▀▀ ▀▀ ▀▀

Elevated display backlit Second display at rear 3 displays: weight, unit price, total price Weigh range: 3 to 30 kg Readout: 1 to 10 g

▀▀

▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

CH Series

Industrial strength Stainless steel weighing bridge Weighing with tolerance range (checkweighing) Weigh range: 600 to 3,000 kg Readout: 200 to 1000 g

51

▀▀

▀▀ ▀▀ ▀▀

Ideal for weight of fruits, fish, etc plus control of goods-in & goods-out Extractable tape measure (100 cm) Weigh range: 15 to 50 kg Readout: 20 to 100 g

Australia - Free Call: 1800 251 799

Configuration Guides

▀▀

Modes: weighing, counting, dispensing, recipe weighing, checkweighing, totalising with daily total, % determination, etc Weigh range: 6 to 300 kg Readout: 0.05 to 20 g

BAN Series

Personal Protection

▀▀

IKT Series


Peristaltic Drives

(refer Selection Guide on page 87 to personalise your needs)

Economical Integrated Pump Head System ▀▀ ▀▀ ▀▀ ▀▀

L/S Compact Single-Channel Pump

▀▀

Simple & cost effective option Low flow sampling & pumping Pump head accepts continuous lengths of tubing for clean flow paths Dual-channel model delivers synchronous flow from two separate channels; single-channel model delivers highest flow rate Flow rates 1.8 mL/minute to 220 mL /minute

#77240-20

Digital Dispensing Pump ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Advanced digital drive offers programmable repeat dispensing functionality Cumulative volume totaliser & batch count Heads are stackable for expanded channel capacity Heads accept multiple tubing sizes for application flexibility Graphical LCD shows four operating modes: continuous run, timed dispense, copy dispense, volume dispense

L/S Digital Pump System with Easy-Load II Pump Head #77921-75

Economical Variable Speed ▀▀ ▀▀ ▀▀

Simple analogue speed control Flow rates 0.42 mL/minute to 2900 mL/minute Accepts stackable pump heads

L/S Economy Variable Speed Drive #07554-85

Portable Dairy Process Pump System ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Handles viscous materials Non contaminating Self-priming (no valves) Easy cleanup - IP55 for washdown Delivers up to 8 LPM with I/P 73 tubing Easy-Load pump head facilitates quick tubing changes between samples Handle for convenient portability

I/P Drive with Easy Load Head #77963-10

Sanitary Sampling Pump System ▀▀ ▀▀ ▀▀ ▀▀

L/S SS Digital Pump #77975-25

▀▀ ▀▀

Drawing sanitary samples from process lines Stack pump heads to draw samples from multiple lines simultaneously Drive is easily programmed for repetitive sampling; program time delay (pause) between runs Control drive remotely via 0 to 20 mA, 4 to 20 mA or 0 to 10 V signal - signal is scalable & invertible Easy-Load II pump head permits fast tubing changes; pumping is contamination free IP66 & NEMA 4X rated - easily cleaned or washed down after use

Programmable ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

316 stainless steel drive Ideal for higher flow food & beverage applications IP66 & NEMA 4X rated Programmable dispensing Flow rates from 0.0006 to 19 L per minute

I/P Digital Process Drive #07575-30

www.johnmorrisgroup.com

52


Physical Properties

Peristaltic Pump Heads

High Pressure - High Flow Rate

Automatic Tubing Retention

Standard For Higher Flow

Compositional Analysis

(refer Selection Guide on page 87 to personalise your needs)

Optical Analysers

L/S Easy Load II

#07019-21

▀▀

Stack 2 pump heads to double flow rate

▀▀ ▀▀

▀▀ ▀▀ ▀▀

▀▀

#77600-62

Reduced pulsation with 4 roller rotor Multiple tubing sizes accepted Adjustable occlusion options for higher pressure applications Flow rates from 0.06 to 2300 mL/minute

▀▀

▀▀

▀▀

Up to 19 L per minute for high volume dispensing Stainless steel rollers, bearings & rotor plates Ideal for viscous fluids

Ideal for Food & Beverage Processing & Dispensing ▀▀ ▀▀

#06418-14

▀▀ ▀▀

▀▀

Solve-Flex Pump Tubing

▀▀

#96446-16 ▀▀ ▀▀

▀▀ ▀▀ ▀▀ ▀▀

#96412-14

FDA, ADCF-Compliant Good chemical resistance Ideal for acid & solvent transfer High-temperature resistance, opaque black

▀▀

Norprene Tubing #06404-14

▀▀

▀▀ ▀▀

▀▀

Silicone Tubing (Platinum Cured)

▀▀

▀▀

Fewer potential leachables Accommodates a wide temperature range Low compression set, odourless, nontoxic, translucent

▀▀

Kit contains o 22 different formulations & descriptions o Selection guide o Instructions on how to test your tubing o Complete ordering information Ask for your free kit today

Tubing Test Kit

53

Australia - Free Call: 1800 251 799

Configuration Guides

#96410-14

▀▀

Free Tubing Test Kit

Personal Protection

Ideal for Pharmaceutical & Biotechnology Use

Heat, ozone &UV light resistant, nonaging, non-oxidizing, superior acid & alkali resistance FDA 21 CFR 177.2600, NSF-51, REACH (non-DEHP) Compliant, RoHS Compliant -51°C to 135°C Up to 10,000 hours tubing life

Condition Monitoring

Viton Tubing

Ideal for Pressure/ Vacuum Applications

Trade Waste

Good Chemical Resistance

Ideal for pumping extremely aggressive solvents (ammonia, THF & chloroform) Plasticizer-free fluoropolymer inner layer (hydrophobic, & resists absorption/ adsorption of aqueous fluids) Thermoplastic-elastomer outer layer (for longer life) Temperature range -51°C to 132°C

Laboratory Essentials

Tygon E-Food Tubing

B-44-4X Formulation (transparent) Non-wetting, odourless, tasteless & nontoxic Sterilize with Ethylene Oxide or autoclave FDA 21 CFR 175.300, EU Food, NSF-51, 3A, REACH (non-DEHP) Compliant, RoHS Compliant, ADCF compliant

Unique Tubing for the Harshest Chemicals

Vacuum Pump Solutions

Peristaltic Pump Tubing

Fermentation

▀▀

Single tubing size accepted Flow rates 0.01 to 13 L/minute Clear PC housing Ideal for dispensing & metering

▀▀

I/P High-Performance Pump Head

#77200-60

Separation Science

I/P Standard Pump Head


Syringe Pumps Ideal For Low-Flow & Low-Pressure Applications ▀▀ ▀▀

Accurate to ±0.5%; Reproducibility of ±0.1% Backlit LCD guides you through setup & operating procedures

Single-Syringe Infusion Pump #74900-05

Flow rates of 0.2 μL/hr to 500 mL/hr Accepts glass, plastic or stainless steel syringes (from 10 μL to 60 mL)

Dual-Syringe Infusion/Withdrawal Pump #74900-25

Flow rates of 0.001 μL/hr to 147 mL/min Accepts glass, plastic or stainless steel syringes (from 10 μL to 140 mL)

Fluid Management Components Luer Fittings

Male & female luer fittings & connectors, luer adapters & accessories - >120 separate configurations in nylon, polypropylene, polycarbonate & PVDF - many colours & special material options available

Tube-to-Tube Fittings

Connectors & fittings from 1.6 mm to 25.4 mm ID in >100 separate configurations straight, elbows, tees, crosses, Ys, multi-port connectors & multiple straight, elbow & tee reducer combinations

Quick Connect Fittings

Two distinct families: XQC Series for quick disconnect couplings & SBL Series for applications covering 3.2 mm to 9.5 mm ID tubing

Threaded Fittings

Plastic tubing fittings & connectors to join tubing to commonly used threaded ports - available in straight, elbow & tee connections

Stopcocks

Designed to easily control the flow of a liquid or gas through the use of an on/off diverter & offered in 3 configurations (1-way, 3-way, 4-way)

Check Valves

Two product lines offered: single & double check valves

Clamps

Easily operated with one hand, allows effortless attachment of fittings to bag ports & filters – simply rest the fitting in the slot, lightly grip the surrounding handles & listen for the sound of clicks to confirm a secure connection

Tuohy Borst Adapters

Convenient bag sizes of 100 & 25 with larger sizes available on request

Contact John Morris Group for details of our extensive range of fittings & fluid management components

www.johnmorrisgroup.com

54


Physical Properties

Sonication

Compositional Analysis

Small Scale Ultrasonic Processing ▀▀ ▀▀

VCX-130

▀▀

Optical Analysers

▀▀

Ideal for cell lysing, dispersion, homogenisation & much more 130 Watt Processor (20kHz frequency) with timer & pulser Working volume: 150 μL to 150 mL (subject to probe) Ready for operation - includes converter & 6 mm probe

The Best Seller in Mid-Range Processing ▀▀ ▀▀ ▀▀

Exclusive energy set-point functionality for enhanced reproducibility Working Volume: 250 μL to 1L (subject to probe) 750 Watt processor (20 kHz frequency) Ready to go - includes converter & 13 mm probe (threaded or solid - please specify when ordering)

Separation Science

▀▀

VCX-750

Fermentation

Homogenisers General Use ▀▀ ▀▀

▀▀

Vacuum Pump Solutions

▀▀

Suited for a wide range of applications - handheld or with optional stand for hands-free Use with either stainless steel rotor-stator generators or disposable plastic tip probes (tip adapter required) Processes a wide range of samples from 0.05 mL to 100 mL Variable speed from 5,000 rpm to 30,000 rpm

LabGEN 125

▀▀ ▀▀ ▀▀

IKA 10

▀▀

Compact & great for high-speed hand held operation Variable speed control from 8,000 to 30,000 rpm Rotor-stator generator uses a ‘pump-like’ action to constantly draw in sample Through a combination of shear, impact, collision & cavitation, the generator rapidly disperses & disintegrates the material suspended in the media

Trade Waste

Blenders ▀▀ ▀▀ ▀▀

Condition Monitoring

1 Litre Two-Speed Laboratory Blender Up to 22,000 rpm Glass or Stainless Steel container available 3 minute timer

Personal Protection

Waring Blender

2 Litre Heavy Duty Laboratory Blender ▀▀

▀▀

Up to 20,000 rpm Stainless Steel container Heavy duty motor & blades Two-Speed Blender

55

Australia - Free Call: 1800 251 799

Configuration Guides

▀▀

Laboratory Essentials

Work Horse


Wide Range of Filters Nylon Membrane Filters No Pre-Wetting Required ▀▀ ▀▀ ▀▀

Inherently hydrophilic & compatible with many aqueous & organic solvents & solutions Withstand up to 5 autoclave cycles at 121°C for 30 minutes Applications: solvent filtration; HPLC sample preparation; sterilising & final filtration; bioassays

Glass Fibre Filters 100% Borosilicate Glass & 100% Free Of Bonding Agents Offer fine particle retention & high flow rate Choice of grades: o GF/1F - ideal for high-efficiency general lab filtration, gravimetric analysis of airborne particulates, high-volume air samples, stack sampling & absorption method of air pollution monitoring o GF/3F - used in liquid scintillation counting (LSC), collecting suspended solids from potable water & natural wastes, cell harvesting ▀▀ ▀▀

Chromatography Filters Maximise Sample Recovery Bi-directional flow Withstand pressure up to 7 bar (100 psi) ▀▀ Choice of membrane material: o Nylon Chromatography Filters - have low extractables - great for research & analytical applications o PES Chromatography Filters - are naturally low protein binding & offer wide chemical compatibility. o PTFE Chromatography Filters - stand up to the most aggressive compounds & can be used under extreme chemical or temperature conditions o PVDF Chromatography Filters - ideal for solutions that are difficult to filter ▀▀ ▀▀

Sterile Air Vent Filters Protect Your Culture From Airborne Contaminants ▀▀ ▀▀ ▀▀

Stepped hose barb connections accept 3.18 to 6.35 mm inner diameter tubing Hydrophobic PTFE membrane & PP housing Withstands up to 30 autoclave cycles at 121°C for 20 minutes (or 3 cycles at 134°C for 30 minutes)

Sterile Gridded Cellulose Nitrate Membranes Identify Colonies Easily ▀▀ ▀▀ ▀▀

www.johnmorrisgroup.com

Sterilised by EtO & individually wrapped Hydrophilic membranes contain no extractables & don’t affect pH of the medium Applications: aqueous or protein filtration; microbiology analysis; particle collection & testing; sterile filtration

56


Physical Properties Compositional Analysis

Filtration Systems Vacuum filtration is one of the most common applications used for sample preparation

Single Vacuum Filtration

Filtration Assembly Optical Analysers Separation Science

Labglass Filtration Assembly

Number of Heads/Stages: 1/1 Max Pumping Speed: 0.7 m3/h Ultimate Vacuum: 100 mbar

Sintered glass support provides even, flat support structure for membrane filters ▀▀ Choice of: o 47 mm diameter with 300 mL capacity o 90 mm diameter with 1,000 mL capacity ▀▀ Filtering flasks sold separately

Fermentation

ME 1 / ME 1C* ▀▀

* ME 1C is chemical resistant

Filtration Assembly

Laboratory Essentials

Simultaneous Vacuum Filtration

Vacuum Pump Solutions

(without gas ballast)

Trade Waste Condition Monitoring

ME 2 NT / ME 2C NT* ▀▀ ▀▀

(without gas ballast)

▀▀

* ME 2 NT C is chemical resistant

▀▀

Manifold comprises: Two- & three-way valves feature PTFE stopcocks for smooth control Valves provide independent control at each branch for vacuum & venting Connect 3 or 6 filter holders to 1 vacuum source

Personal Protection

Number of Heads/Stages: 1/1 Max Pumping Speed: 2.0 m3/h Ultimate Vacuum: 70 mbar

Vacuum Filtration Manifold with Filter Holder

Configuration Guides

57

Australia - Free Call: 1800 251 799


Vessels & Containers Heavy Duty HDPE Carboys With Spigot ▀▀ ▀▀ ▀▀

HDPE Carboy

▀▀

Economical, durable carboys are resistant to most chemicals Swing handle allows easy carrying HDPE closure contains tag holes for identification Sizes from 5 L to 50 L

#06035-81

PP Carboys with Handle ▀▀ ▀▀ ▀▀ ▀▀

Graduated in descending 1 L increments to deliver liquids easily Sizes from 5 L to 20 L; Octagonal shape increases rigidity when full Offset neck makes filling & pouring easy Moulded shoulder handle sealed at ends to prevent contamination Heavy-Duty PP Carboy #62507-10

Safety-Labelled Wash Bottles ▀▀ ▀▀ ▀▀

Design automatically vents volatile solvent vapour 500 mL capacity, 5 per pack Colour coded for easy identification - red, blue, orange, green

Wash Bottle #62303-40

Bottle Top Dispenser ▀▀ ▀▀ ▀▀

Excellent chemical compatibility & precise dispensing - easy to use with simple, quick volume adjustments Wetted materials: FEP,PTFE, borosilicate glass Multiple volume range model available

Bottletop Dispenser #25208-10

Quality Control Gelation Timer ▀▀ ▀▀ ▀▀

Techne Gelation Timer

Audible & visual alarms alert you at the gelation point Simple-to-use push buttons with large LED display Stainless steel plungers remove for easy cleaning

#98930-43

Viscosity Cups ▀▀ ▀▀ ▀▀

An easy & economical way to measure viscosity ±3% production tolerance Each stainless steel cup meets dimensions as specified in ASTM D 4212 standards

Gardco EZ Series #08700-00

Moisture Meter ▀▀ ▀▀ ▀▀

Hand held - use on cardboard, wall board, sheet rock, plaster, concrete & mortar Dual measurement scale LCD with bar graph & digital display Measures wood moisture from 6 to 44% with replaceable threaded measurement electrode pins

Moisture Meter #86531-05

www.johnmorrisgroup.com

58


Physical Properties

Small

Versatile

Economical

Compositional Analysis

Centrifuges

Optical Analysers

2-7

▀▀

Capacity Rotors

▀▀

PCR Tubes Tubes

▀▀ ▀▀

1.5 to 100 mL (up to 30 tubes)

▀▀ ▀▀

4-5L

21,475 15,300

4,643 4,700

Up to 192 tubes or 12 strips of 8 tubes 1.5 to 400 mL (up to 100 tubes)

Swing-out or fixed-angle

Swing-out or fixed-angle

▀▀ ▀▀

Up to 104 tubes 1.5 to 750 mL (up to 80 tubes) Swing-out

Fermentation

Babcock Centrifuge ▀▀ ▀▀

▀▀

Specifically designed for Babcock testing Ideal for the dairy industry Includes heater, thermostat, thermometer, visiscope & brakes in a cast aluminum housing 8 or 12 bottle models

Vacuum Pump Solutions

▀▀

Babcock

Glass Babcock Bottles ▀▀

Essential for fat analysis Body of each bottle is a reaction chamber, while the graduated neck is a measuring device

Babcock Bottles

Sieves & Separators

Laboratory Essentials

▀▀

Separation Science

Max RCF (x g) 2,540 Max Speed (rpm) 4,000

3-16L

Testing Sieves ▀▀

Testing Sieve

▀▀

Stainless steel testing sieves Serialised Equivalent to ASTM E11-09 compliance

Trade Waste

▀▀

▀▀ ▀▀ ▀▀

Product is only in contact with polished stainless steel parts Noiseless, high frequency vibrations for efficient sifting & particle separations Portable & stationary options

Vibro-Separator

Personal Protection

Extraction Electromantle Extraction Heater ▀▀

▀▀ ▀▀

Allow liquids with different boiling points to be heated &/or stirred next to each other Stir or heat your solutions simultaneously in each position Flask capacities from 100 to 1,000 mL Choice of three or six positions, with or without stirring function

Extraction Heater

59

Australia - Free Call: 1800 251 799

Configuration Guides

▀▀

Condition Monitoring

Vibro-Separators


Shakers ▀▀ ▀▀ ▀▀

Variable speed Features ‘touch’ & continuous operation Maximum speed 2,850 rpm

Vortex Mixer

▀▀ ▀▀ ▀▀

Orbital Shaker

▀▀ ▀▀

▀▀ ▀▀

Reciprocating Shaker

▀▀ ▀▀ ▀▀

▀▀ ▀▀

Rocking Shaker

▀▀ ▀▀

▀▀ ▀▀

Wave Shaker

▀▀ ▀▀

▀▀ ▀▀ ▀▀

Ideal swivel motion with a maximum shaking weight of 2 kg Digital display shows speed & time settings 4 mm orbit Speed from 80 to 800 rpm 5 to 50 minute or continuous timer

Soft-start function brings motor up to speed gradually Built-in digital timer & continuous operation mode Adjustable vessel containment system fits most flasks/bottles Reciprocating stroke 20 mm with 10 kg maximum load Speed from 25 to 50 rpm

Variable speed controls Rocking angle adjustable through 20° from horizontal Maximum speed 160 rpm Maximum load 6.8 kg

Run continuously or up to 12 hours with built in timer Smooth orbital wave motion to mix through any medium Speed from 5 to 120 rpm with 9 kg maximum load Angle of 0° to 12°

Timer from 1 minute to 99 hours Speed from 5 to 80 rpm with 2 kg maximum load 360° rotation

Overhead Shaker

▀▀ ▀▀ ▀▀ ▀▀

Rolling Shaker

www.johnmorrisgroup.com

▀▀

6 roller - both rocking & rolling movement Mixing at 33 rpm Use in cold rooms (down to 4°C) or incubators (up to 60°C with 80% humidity) Ideal for samples where minimum aeration is required Stack up to 3 shakers (kit sold separately)

60


Physical Properties

Stirring

Compositional Analysis

20 L Digital ‘Round’ Stirring Hot Plate ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Optical Analysers

▀▀

Constant speed irrespective of viscosity changes Aluminium plate ensures optimal heat transfer Ceramic coated (chemically resistant) top plate Precise temp & speed control IP42 rated die-cast body Includes PT100 sensor

#1218678

15 L Digital ‘Square’ Stirring Hot Plate ▀▀ ▀▀ ▀▀ ▀▀

Constant speed irrespective of viscosity changes Ceramic coated top plate & body resist acids, bases & solvents Precise temp & speed control IP42 rated die-cast body Includes 1.8 m cord with plug

Separation Science

▀▀

#15956-31

Fermentation

Analog Stirring Hot Plate with LED Temp Indicator ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

#04801-62

Vacuum Pump Solutions

▀▀

15 cm square top Coloured LED indicates when plate reaches temp set point Ceramic coated (chemically resistant) top plate Up to 2,000 rpm Quick heat-up times Includes fitting for attaching a support rod

Digital Reversing Mixer ▀▀ ▀▀

#50004-10

▀▀ ▀▀

▀▀

MIX 1 #30001

▀▀ ▀▀

Trade Waste

Ultra Flat Magnetic Stirrer 10 L stirring volume @ 100 to 2,000 rpm 100% maintenance free with IP64 Protection Rating 3 year warranty

Condition Monitoring

Powerful Low Volume Stirrer ▀▀

MIX-1 eco #30101

▀▀ ▀▀ ▀▀

Up to 3 L stirring volume Small footprint - perfect for the busy lab 100% maintenance & wear free, IP64 Rated 3 year warranty

Personal Protection

Submersible (6 Position) Stirrer ▀▀ ▀▀

IP68 rated with heat resistance to 50oC in water & air Maximum 3 L per position @ 1,200 rpm Hermetically sealed housing protects against aggressive gases

Configuration Guides

▀▀

MIXdrive 6 #40006 + #90400

Laboratory Essentials

Time your cycles for more efficient mixing (timer set from 1 minute to 2,000 minutes in 1 minute increments) Clockwise & counter-clockwise rotation for a variety of mixing applications Reversing timed cycles to control vortexing & aeration Overload protection Brushless DC motor maintains speeds at most viscosities

▀▀

61

Australia - Free Call: 1800 251 799


Temperature Control Systems Model

Temp Range

Cooling Capacity @ 20°C (kW)

Heating Capacity (kW)

Fill Volume (L)

Flow Rate (L/min)

Diamond XS

+20° to +95°C

-

2.0

13L

14

Heated immersion circulator & water bath combination - perfect for mobile chefs & small kitchens preparing sous vide dishes - data logging software for HACCP compliance

Pura 14

+25° to 99.9°C

-

1.3

1 to 14

-

Heated waterbath for temperature control of samples, cell cultivation, incubation, material testing, food & beverage testing

SW22

+20° to 99.9°C

-

2.0

8 to 20

-

Heated shaking water bath ideal for cell cultivation, fermentation, homogenization, incubation, food & beverage testing

Corio CD-B5

+20° to +150°C

-

2.0

3.5 to 5

15

Heated immersion circulator suitable for a large variety of applications in chemistry, analytics, material testing & more

F38-ME

-38° to +80°C

0.92

2.0

45

11 to 16

Beer forcing test refrigerated/heating circulating bath simulates the aging process to determine the product life of beer before clouding

F500

0° to +40°C

0.5

-

5 to 7.5

24

Recirculating cooler for soxhlet extraction apparatus & rotary evaporators - consistent reproducible condensation temperatures, without influence of ambient fluctuations

Corio CD-200F

-20° to +150°C

0.22

2.0

3 to 4

15

Refrigerated/heating circulator - temperature control of samples in a circulator bath or an external application - suitable for temperature control of measuring cells, refractometers, polarimeters, photometers, viscometers, fermenters, rotary evaporators, rheometers & more

www.johnmorrisgroup.com

62


Physical Properties

Analog Dry Block Heaters ▀▀

▀▀

▀▀

▀▀

Two separate temp adjustment knobs with 1 to 10 dial markings for low & high temp ranges Low-range knob adjusts from ambient +5°C to 100°C High-range knob adjusts from 75°C to 150°C Separate thermometer or probe is needed to set & verify the setpoint temp Uniformity ±0.4°C

Accepts 2 Blocks

Optical Analysers

▀▀

Accepts 1 Block

#36600-13

#36600-15

Separation Science

Digital Dry Block Heaters ▀▀ ▀▀

▀▀

▀▀

Accept 1, 2 & 3 blocks Exceptional temperature uniformity Select a temperature with ease (in 0.1°C increments), rapid heat-up excellent stability to maintain results Features include timer, audible alarm, built-in temp calibration mode, overshoot protection & independent LED displays Temperature range: Ambient to 120ºC

Fermentation

▀▀

Compositional Analysis

Heaters + Heating Blocks

1 Block

Stirring Drybaths

Laboratory Essentials

15 Synchronized Stirring Positions ▀▀ ▀▀ ▀▀

▀▀

Separate control for stirring & heating Suitable for 250 mL lab flasks & 400 mL beaker glasses Stirring speed range from 100 to 2,000 rpm 200°C maximum heating temperature Includes external control unit (excludes glassware)

Stirring Drybath 15-250

▀▀ ▀▀

▀▀

▀▀ ▀▀

Stirring Drybath 8-250 ERL

63

Australia - Free Call: 1800 251 799

Configuration Guides

▀▀

Personal Protection

▀▀

Separate control for stirring & heating Stirring speed range from 100 to 2,000 rpm 10-step power settings of the stirrer - high power setting for viscous liquids Heating block made of resistant aluminium alloy, PTFE-coated for increased chemical resistance Maximum heating temperature +200 °C Automatic compensation of physically determined loss in stirring power which can come up to 40% at high temperatures Includes 8 contact adapters for optimized heat transfer

Condition Monitoring

8 Synchronized Stirring Positions Suitable for 250 mL Erlenmeyer Flasks

Trade Waste

▀▀

Vacuum Pump Solutions

#36600-02


Thermometers Safety Coated Thermometer - Eliminate Glass Splitting & Shattering FEP/PTFE safety coating - for breakage protection Organic blue filled precision ASTM thermometers Measurement range from -20°C to 150°C: Accredited to ASTM Standards Remove the hassle & danger of mercury spills & broken glass from your lab

▀▀ ▀▀ ▀▀ ▀▀

Digital Min/Max Alarm Thermometer ▀▀ ▀▀ ▀▀ ▀▀

Digital Thermometer

▀▀

Memory date/time Display of 3 temperatures Measuring range: -50°C to +70°C DAkkS-calibration (2 calibration points ) Calibrated at: -10°C & +40°C

#65809/04/2P

Food Safety Infrared Thermometer with Probe A combination contact/non-contact thermometer for all food applications Sealed IP54 housing makes for easy cleaning Rapidly indicates if food temperature is in the bacterial growth safety zone

▀▀ ▀▀ ▀▀

IR Thermometer #35625-40

Hydrometers Unbreakable Hydrometers - Fruits, Grapes, Dairy, Breweries, etc ▀▀ ▀▀ ▀▀ ▀▀

Unbreakable (no glass) & high degree of transparency Precision density hydrometers (British Standards) Plastic hydrometers (According to Baumé) Made in Germany with high precision & reproducibility

Economy Ovens Economy Gravity Convection Ovens ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Gentle airflow ideal for sterilization, drying & delicate samples Programmable for delayed start and stop Easy-to-clean Stainless Steel interior Dual-wall door opens to 180° Choice of sizes: 50 L, 100 L, 150 L

Gravity Convection Oven #52412-86

Economy Mechanical Convection Ovens ▀▀ ▀▀ ▀▀ ▀▀

PID temperature control for greater temperature uniformity Over temp & open door alarms Easy to clean Stainless Steel interior Choice of sizes: 50 L, 100 L, 150 L

Mechanical Convection Oven #52412-92

www.johnmorrisgroup.com

64


Physical Properties

▀▀ ▀▀ ▀▀

Compositional Analysis

Sanitary Pressure Transducers Designed to meet 3A standards Fully sealed to withstand external high-pressure washdowns Self-contained electronic package

Transducer 3A Rated

Optical Analysers

#98072-06

Analog Flowmeters with PTFE Components ▀▀

▀▀

Monitor & control easily with high-precision valve option Vertical-tangential locator line provides readings with hairline accuracy Anodized aluminium frame protects the heavy-walled glass flowtube Correlated Glass/PTFE Flowmeter

Separation Science

▀▀

#03216-90

▀▀

GPI Flowmeter/Totalizer #05610-04

▀▀ ▀▀

Fermentation

Commercial Grade Flowmeters/Totalisers Two totalizers allow for process or period-specific volume monitoring Battery-powered to eliminate the need for expensive wiring NEMA enclosure is suitable for indoor/outdoor use in dusty, dirty & wet environments

Vacuum Pump Solutions

Sampling Devices Sample Dipper & Container ▀▀ ▀▀

Sampling Dipper

▀▀

Individually wrapper & sterilised All-in-one sample system includes handle and removable dipper/sample container Sterile sampler allows liquid or powder sample to be taken & sent for testing in the same container eliminating the risk of cross contamination Choose from polystyrene or shatterproof polypropylene

Laboratory Essentials

▀▀

& Container

Trade Waste

#06282-75

Long Handle Sample Dipper ▀▀

▀▀

Includes replaceable polypropylene (PP) cup that screws onto the handle Two pouring spouts on the cup allow pouring from either side High-density polyethylene (HDPE) handles are ribbed for a sure grip - end has hook for hanging

Condition Monitoring

▀▀

Polypropylene Dipper #06282-05

▀▀ ▀▀ ▀▀

Mighty Gripper

65

Bottle Dropper

Australia - Free Call: 1800 251 799

Configuration Guides

▀▀

Choose from a range of inexpensive handles Bottle grippers hold plastic or glass bottles/jars from 250 mL to 1 litre Easy-clean stainless steel Ideal for grab sampling from stream banks, shorelines, oxidation ponds, chemical or petroleum storage tanks … wherever stream contact is not desirable or possible

Personal Protection

Grab Sampler & Bottle Dropper


TRADE WASTE Water Samplers Model

Refrigerated

Selection Guide Portable

Bottle Configuration

Power Source

Sequential (multiple)

Composite (single)

GLS

-

Yes

-

Yes

AC, DC or Solar

3700

-

Yes

Yes

Yes

AC, DC or Solar

6712

-

Yes

Yes

Yes

AC, DC or Solar

5800

Yes

-

Yes

Yes

AC

6712FR

Yes

-

Yes

Yes

AC

Glacier

Yes

Yes

-

Yes

AC, DC or Solar

Avalanche

Yes

Yes

Yes

Yes

AC, DC or Solar

Compact Sampler ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Priority pollutant sampling in industrial applications (where a full size sampler is too large) Configuration: 1 x 10 litre bottle composite sampler Light weight with single hinged handle Full size sampling capability yet ultra compact - fits inside a standard manhole Simple programming for quick & easy set-up Applications - ideal for trade waste & first-flush sampling

GLS

Full Size Performance Plus Flexibility ▀▀ ▀▀

▀▀ ▀▀ ▀▀

3700

▀▀

Sample collected on ‘time’, ‘flow-signal’ or external logger trigger signals Accurate, repeatable sample volumes due to exclusive LD90 Liquid Detector & pump revolution counting system Configuration: 24 bottles sequential or 1 x 10 litre bottle composite Enhanced sample preservation via thick, foamed-in-place insulation & twin-walls Eliminate sample cross-contamination due to the automatic suction line rinsing Applications - wastewater effluent, permit & pre-treatment compliance

Full Size & Full Featured ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

6712

▀▀

Built-in data logger automatically records sampling routine, flow & water quality data from optional sensors Preserves samples in harsh conditions due to foam-insulated base with space for ice packing Retrieve data collection via GSM modem (optional) Configuration: 24 bottles sequential or 1 x 10 litre bottle composite Accurate samples via pump revolution counter & patented liquid detection sensor Optional SDI-12 Input for water quality sensors & rain gauge Applications - wastewater effluent, permit & pre-treatment compliance

www.johnmorrisgroup.com

66


Physical Properties

All-Weather Plus Refrigerated Sampler ▀▀ ▀▀ ▀▀

▀▀ ▀▀

Top to bottom insulation for best in class stationary sampling in industrial waste water applications Configuration: 2, 4 or 24 bottles sequential or 1 x 10 litre composite o o Operating range of -29 C to +49 C Long-life & reliability in corrosive treatment plant conditions thanks to heat-treated polyester powder coating which protects the refrigeration system Energy efficient, high performance cooling Applications - wastewater treatment plants, industrial pre-treatment, effluent sampling

Optical Analysers

5800

Compositional Analysis

▀▀

Corrosion Proof Plus Advanced Sampling Polyester resin fiberglass & UV-resistant gel coat provides a smooth, non-porous finish Complex programs including ‘smart sampling’ event notification (triggered on any combination of up to 16 inputs) - internal memory ▀▀ SDI-12 interface provides ‘plug-&-play’ connection with compatible measuring devices ▀▀ Automatic built-in heater ensures samples won’t freeze (even when temperatures drop to -29°C) ▀▀ Configuration: 24 bottles sequential or 1 x 10 litre bottle composite ▀▀ Applications - wastewater effluent, permit & pre-treatment compliance in extreme temperature environments ▀▀ ▀▀

▀▀ ▀▀ ▀▀

▀▀

Glacier

Advanced Sampling & Data Logging ▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Avalanche

Flexible sampling routine based on time, event or flow Configuration: 14 x 1 L sequential or 10 or 20 L composite Powered by 12 VDC batteries or 240 VAC Unique power saving cooling system remains on standby until first sample is taken Optional SDI-12 input for water quality sensors & rain gauge Applications - anywhere you need advanced sampling capability combined with data logging & communications for flow & water quality parameters

Trade Waste

Water Sampling Pumps ▀▀ ▀▀ ▀▀ ▀▀

Compact DC Powered Pump Drive ▀▀ ▀▀

▀▀

Masterflex L/S DC Powered Drive

67

Australia - Free Call: 1800 251 799

Configuration Guides

▀▀

Ideal for sampling & fluid transfer in the field/OEM applications Flow rates from 34 to 2700 mL/min (dependent on tubing size) Accepts 8 different pump heads; 24 VDC power – Three Wire, 16-gauge, 30 cm long Completely controlled by power source: vary input voltage to change speed, reverse input voltage to change direction

Personal Protection

Masterflex E/S

Variable speed, economical & easy to operate for basic applications Self-contained housing floats for up to 30 minutes in water Reversible flow & prime/purge function; AC or DC power or unit’s rechargeable battery Flow rates from 4.2 to 1,100 mL/min (depends on tubing size) Contact us for pump head & tubing options

Condition Monitoring

Peristaltic Water Sampling Pump - Portable ▀▀

Laboratory Essentials

▀▀

Vacuum Pump Solutions

▀▀

Small, lightweight & mobile - powered by 12 VDC batteries or 240 VAC Refrigeration ensures sample preservation Optional mobility kit with pneumatic tyres Configuration: 1 x 10 litre bottle composite Applications - stormwater sampling, biomonitoring (where accurate sample preservation is needed), influent & effluent sampling, anywhere you need sampling mobility plus reliable, ice-free cooling

Fermentation

Light-Weight & Mobile Refrigerated Sampler

Separation Science

6712FR


Flow Meters Water Flow Monitoring Instrument Selection Guide Continuous-Wave Doppler

Technology

Pulse Doppler Velocity Profiling

Non-Contact Ultrasonic

Bubbler

Submerged Non-Contact Non-Contact Probe Laser Flow Laser Flow Velocity Meter Sensor

Signature Area Velocity Meter

2150 Area Velocity Flow Meter

accQpulse Velocity Profiler

2110 Ultrasonic Flow Meter

Signature Ultrasonic Meter

Signature Bubbler Meter

Signature Submerged Probe

2160 Laser Flow Meter

Signature Laser Flow Meter

AC Power

Yes

Optional

Optional

Optional

Yes

Yes

Yes

Optional

Yes

DC Power

Optional

Yes

Yes

Yes

Optional

Optional

Optional

Yes

Optional

-

-

-

Yes

Yes

Yes

Yes

-

-

Compound Pipes (Surcharge)

Yes

Yes

Yes

-

-

-

-

Yes

Yes

Small Channels (<36”/0.91 m)

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Large Channels (>36”/0.91 m)

Yes

Yes

Yes

-

-

Yes

Yes

Yes

Yes

Model

Primary Device (Weirs & Flumes)

Multi-Technology Open Channel Flow Meter ▀▀

▀▀

▀▀

Signature Flow Meter

▀▀ ▀▀

Suitable for waste water treatment plants, outfall & industrial pre-treatment compliance Supports flow measurement technologies including: • Doppler area velocity • Non-contact laser velocity • Ultrasonic Signature with Ultrasonic • Bubbler • Pressure transducer Calculates flow using standard open channel level-to-flow conversions as well as user defined equations or level to flow data points Logs key events such as changes in calibration and power outages to validate data accuracy Suitable for industrial pre-treatment compliance, shallow flow measurement (in large & small pipes), wastewater treatment plants & outfalls

Portable Doppler Area Velocity Flow Meter Designed for open channel flow measurements (measuring mean velocity) Less sensor maintenance due to chemical resistant epoxy-encapsulated coating ▀▀ Integral high resolution pressure transducer for drift-free level measurement ▀▀ IP-68 submersible enclosure, powered by two 6V alkaline batteries ▀▀ Up to four 2100 Series flow modules can be networked ▀▀ Variable rate data storage lets you change the data storage interval when programmed conditions occur - assuring maximum information about an exceptional event (such as an overflow) ▀▀ Suitable for portable & permanent-site AV flow monitoring (for inflow & infiltration, capacity assessment, sewer overflow & sewer studies), measuring shallow flows in small pipes ▀▀ Able to stack modules to build an integrated system (to monitor multiple flow streams at the same time), remotely locate modules & connect them via cable ▀▀ ▀▀

www.johnmorrisgroup.com

68

2150 Area Velocity Flow Meter


Physical Properties

Intrinsically Safe & Portable Area Velocity Flow Meter ▀▀ ▀▀ ▀▀

▀▀ ▀▀

Optical Analysers

2150 EX

Intrinsically safe Area Velocity Flow Module Rugged, submersible enclosure is permanently sealed & IP-68 rated Conductive ABS enclosures with stainless steel connections Pressure transducer venting system automatically compensates for changes in atmospheric pressure to maintain accuracy Rechargeable battery option Suitable for open channel flow measurement in hazardous locations (ATEX Category 1G), portable & permanent-site AV flow monitoring, measuring shallow flows in small pipes, level measurement in explosive or potentially explosive areas (such as manholes, digesters & storage tanks)

Compositional Analysis

▀▀

Area Velocity Flow Meter

Separation Science

Portable Pulse Doppler Velocity Profiler ▀▀

▀▀

▀▀ ▀▀ ▀▀

accQpulse Velocity Profiler

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

▀▀

2110 Ultrasonic Flow Meter

▀▀

Trade Waste

▀▀

Condition Monitoring

Calculate flow in weirs, flumes & streams Digital communication between sensor & flow module makes it immune to RF interference Sensor deflector plate resists condensation Minimal deadband in level measurement Chemically resistant (PVDF) sensor package Modular, stackable design snaps together with other 2100 modules to quickly create application-optimised configurations Variable data storage rates can automatically be switched when conditions vary Suitable for CSO, SSO, I&I, cMOM, SSEs, sewer flow monitoring, open-channel flow measurement, non-contact flow measurement in streams that contain harsh chemicals, grease or suspended solids

Laboratory Essentials

Accurate Non-Contact Ultrasonic Liquid Level Measurement

Vacuum Pump Solutions

▀▀

Rugged, submersible enclosure meets IP 68 protection rating Quad-redundant velocity sensors & depth sensor combined in single housing Measures velocity in non-uniform, rapidly changing, near zero & zero or reverse flow condition thanks to its unique multi-points velocity measurement technology Sensor options for shallow water (up to 1.2 m) or deep water (up to 4.9 m) Never need to calibrate unit on-site Data quality verification information (signal strength & correlation) Suitable for wastewater collection systems & treatment facilities, combined sewer systems & outfalls, industrial process & discharges, stormwater conveyance & outfalls

Fermentation

▀▀

Non-Contact Laser Flow Meter ▀▀

▀▀ ▀▀ ▀▀

69

2160 Laser Flow Meter

Australia - Free Call: 1800 251 799

Configuration Guides

Rugged, submersible enclosure - IP 68 rated Quick-connect sensor (Non Contact Laser Flow Velocity Sensor) can be easily interchanged in the field without requiring recalibration Up to four 2100 Series flow modules can be networked Modbus output interface (optional) Suitable for portable or permanent flow measurement & other sewer monitoring programs, shallow flow measurement (in large & small pipes), wastewater treatment plant influent, process & effluent flow measurement, stormwater conveyance, outfalls plus canals

Personal Protection

▀▀


CONDITION MONITORING IP69K-Rated ICP ® Accelerometer Kits ▀▀

▀▀ ▀▀ ▀▀

Vibration monitoring is an integral part of a food & beverage production facility’s predictive maintenance program – vibration sensors detect early developing faults in equipment Withstand 1000 psi sprays of 60°C water typical in a wash-down cycle Each kit includes ICP® accelerometer, M12 connector & IP69K-rated cable assembly Cable assembly includes a corrosion-resistant, stainless steel, 4-socket M12 connector moulded on bright white, polypropylenejacketed cable

High Sensitivity, Low-Noise

Small Footprint, Top Exit

Model 601A92 ▀▀

▀▀

▀▀ ▀▀

Sensitivity: (±20%) 500 mV/g (51 mV/(m/s²)) Frequency Range: (±3dB) 0.17 to 10,000 Hz (10 to 600,000 cpm) Measurement Range: ±10 g (±98 m/s²) Cable in 3, 4.5 or 9 m lengths

Low Profile, Side Exit

Model 603C91 ▀▀

▀▀

▀▀ ▀▀

Sensitivity: (±10%) 100 mV/g (10.2 mV/(m/s²)) Frequency Range: (±3dB) 0.5 to 10,000 Hz (30 to 600,000 cpm) Measurement Range: ±50 g (±490 m/s²) Cable in 3, 4.5 or 9 m lengths

Model 602D91 ▀▀

▀▀

▀▀ ▀▀

Sensitivity: (±10%) 100 mV/g (10.2 mV/(m/s²)) Frequency Range: (±3dB) 0.5 to 8,000 Hz (30 to 480,000 cpm) Measurement Range: ±50 g (±490 m/s²) Cable in 3, 4.5 or 9 m lengths

Bearing Fault Detector Advanced vibration signal conditioner designed to provide the earliest warning of imminent machinery failure ▀▀ Works with a 100 mV/g ICP® accelerometer & delivers two, 4-20 mA output signals that are proportional to the measured vibration levels of operating rotating machinery. ▀▀ In order to enable detection of a wide variety of machinery faults, the 4-20 mA signals are conditioned to characterize 2 unique vibration measurements: o one containing high frequency peak data o the other containing low frequency rms data ▀▀ 4-20 mA signals may be monitored alongside other plant process variables using familiar PLC, DCS, SCADA, alarm & control systems (an additional analog voltage output signal is provided for spectral analysis of the monitored vibration for fault diagnostic purposes) ▀▀ The simplified 4-20 mA signal monitoring approach represents a cost-effective alternative to complex vibration monitoring instrumentation & associated training ▀▀

www.johnmorrisgroup.com

70

Model 682B05


Physical Properties

▀▀

▀▀ ▀▀

4-20mA output vibration transmitters easily interface with automation systems eg programmable logic controllers (PLCs) & distributed control systems (DCSs) Options for velocity or acceleration measurement range Allow data to be monitored & analysed over the long-term to spot potential failures early

Acceleration Vibration Transmitter

ICP® to 4-20 mA Transmitter

Optical Analysers

Vibration Velocity Transmitter

Compositional Analysis

Vibration Transmitters

Separation Science

▀▀ ▀▀

▀▀ ▀▀

▀▀

Output: 4-20 mA Measurement Range: Full-scale value of 5 or 10 g Available in top or side exit versions

Model 682B03

▀▀ ▀▀

▀▀

Converts VAC signal to 4-20 mA output Selectable acceleration, velocity, or displacement scaling Adjustable low & high pass frequency filtering

Vibration Switches ▀▀ ▀▀ ▀▀

Laboratory Essentials

▀▀

Condition Monitoring

Sound Level Meter

Trade Waste

Triggers an alarm or shuts down a machine if the vibration exceeds a pre-set threshold level (due to faults such as imbalance, misalignment, looseness, worn bearings, cracked gears or lack of lubrication) Responds to acceleration, velocity or displacement Works with PLC, DCS & SCADA systems for data trending Advantages over mechanical switches include no moving parts, is more reliable & has a much higher degree of accuracy & repeatability plus time delays can be used (avoid false trips during switch power up, equipment start-up, operational changes & the chance occurrences of short term vibration increases) Series 686B

▀▀ ▀▀ ▀▀

SoundAdvisor 831C

71

Australia - Free Call: 1800 251 799

Configuration Guides

▀▀

Control & monitor data via any PC or mobile device with a standard web interface LCD colour interface IEC 61672-1:2013, ANSI S1.4-2014 Class 1 integrating sound level meter Real-time frequency analysis in 1/1 & 1/3 octave bands (compliant with IEC 61260:2014 & ANSI S1.11-2014 Class 1) >120 dB dynamic range

Personal Protection

▀▀

Vacuum Pump Solutions

▀▀

Output: 4-20 mA Measurement Range: Full-scale value of 0.5, 1.0 or 2.0 ips Available in top or side exit versions

Series 645 to 648

Fermentation

Series 640 to 643


PERSONAL PROTECTION Human Vibration Meter

Polypropylene Shoe Covers

HVM200

Fluid Resistant Lab Coats

PP Shoe Covers

Fluid-Resistant Lab Coat

#86227-92 ▀▀

▀▀ ▀▀ ▀▀ ▀▀

Hand-arm vibration measurement to ISO 5349; Whole body vibration measurement to ISO 2631 Wireless mobile interface Three measurement channels Removable micro SD memory card ISO 8041:2005 compliant

▀▀

▀▀ ▀▀

General Purpose Nitrile Gloves

▀▀ ▀▀ ▀▀

Non-woven fabric helps to contain particulates from shoe soles preventing your shoes from contaminating critical environments Elastic band at the ankles to hold them to your feet Skid free version available

#86468-02 ▀▀

▀▀

▀▀

Earplugs

Face Shield

High Five Gloves

AIRSoft Reusable Earplugs

Wraparound Face Shield

#86233-07

#86310-31

#06767-00

Powder free Textured surface Single use

▀▀

▀▀

Respirators

A soft shell of attenuating material surrounds a cushion of air to provide superior comfort Wash with soap & water

▀▀ ▀▀

Safety Glasses

3M Particulate Respirators

Magnum Glasses

▀▀ ▀▀

N95 respirators for dusty environments Cool flow valve available for high heat areas Adjustable straps for a snug fit

www.johnmorrisgroup.com

▀▀ ▀▀ ▀▀

Adjustable temples High impact PC lens Non slip rubber nose piece

Tyvek Coveralls #86225-21

▀▀ ▀▀ ▀▀

72

Full length Wrap around

Tyvek Coveralls

#86285-00

▀▀

Constructed of 65% polyester/35% cotton & treated with NANO-CARE™ at a molecular level Five-button front closure with three exterior pockets & one interior (lower right) pocket One piece back includes a two button swing belt for added fit

Prevent contamination from dust particles, bacteria, spores & parasites Protection from disinfectants Zippered front, elastic cuffs & hood


Physical Properties

Larson Davis produces a family of personal noise dosimeters that provide ease-of-use, compact size & ergonomic design for noise exposure regulations

Standard

Extremely Tough

Compositional Analysis

Noise Analysis - Dosimeters

Full Featured Optical Analysers Separation Science

Spark 705+

Spark 706RC

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

▀▀ ▀▀ ▀▀ ▀▀ ▀▀

Full report generation & setup Gives surrogate display for 703+ or 705+ Remote control function allows setup & control for 703+ or 705+ Optional detachable mast-style microphone converts unit to a sound level meter Over 100 hours of continuous monitoring plus huge logging memory

Laboratory Essentials

Perfect for personal noise exposure sampling in extreme environments Logging dosimeter with remote response capability Complete report generation & analysis Small, rugged & watertight Detachable microphone Intrinsically safe

▀▀

Vacuum Pump Solutions

▀▀

Logging dosimeter with remote response capability Complete report generation

Fermentation

Spark 703+ ▀▀

Flash Point Testing Economical Testing ▀▀

▀▀ ▀▀ ▀▀

Condition Monitoring

▀▀

Trade Waste

▀▀

Ideal for performing rapid product checks without the cost or delay of sending samples to third party test houses Temperature range 10°C to 130°C or ambient to 300°C (depending on model) Flash point test <2 minutes; Small sample size (2 or 4 mL) Sub-ambient tests & rapid cool down Barometric correction included Options include corrosion resistant or aluminium cups, closed or open cup, a ramp model & ActiveCool version (offers Peltier heating/cooling)

Setaflash Series 3

4 Easy Steps 2

Inject 2 mL sample

4

Press

73

Dip test flame (flash detection is automatic)

Australia - Free Call: 1800 251 799

Configuration Guides

Select test temperature

3

Personal Protection

1


Date: DD / MM / YYYY Contact Name:

Organisation:

Phone:

Email:

Viscometer Selection Guide To ensure we provide the right solution to meet your needs, please complete the following information, scan & email to us (refer back cover for details)

Note:

Testing a Single Sample Complete info for Sample 1 only Testing >1 Sample Complete info for both samples so we may assess the extremities of your requirement: • Sample 1 (being at the low viscosity range) • Sample 2 (being at the high/very high viscosity range)

Sample 1

Sample 2

Please detail the material you are testing

What is the viscosity of your solution?

What is the sample size?

Does the sample have suspended particles?

Low (eg water ≈ 1.0 cP)

Low (eg water ≈ 1.0 cP)

Medium (eg castor oil = 1,000 cP)

Medium (eg castor oil = 1,000 cP)

High (eg honey = 10,000 cP)

High (eg honey = 10,000 cP)

Very High (eg bitumen = >50,000 cP)

Very High (eg bitumen = >50,000 cP)

<5 mL

<5 mL

10-20 mL

10-20 mL

>400 mL

>400 mL

Yes (specify)

Yes (specify)

No

No o

What is the testing temperature? What is the purpose of your testing?

PC connectivity

How soon do you need your new viscometer? What is your budget?

o

C

Quality Control

Quality Control

Research & Development

Research & Development

Software control

Software control

Network

Network

None

None

<1 month <$5K

1 to 3 months $5K-$10K

(this helps to determine the most suitable instrument)

Is there anything else we need to know to assist you?

Version 0517

www.johnmorrisgroup.com

C

74

$10K-$20K

>3 Months >$20K


Date: DD / MM / YYYY Organisation:

Phone:

Email:

To ensure we provide the right solution to meet your needs, please complete the following information, scan & email to us (refer back cover for details) Please briefly describe your application

(include any standards/methods you hope to comply with if known)

Compositional Analysis

Powder Flow Tester Selection Guide

Physical Properties

Contact Name:

Optical Analysers

Please briefly describe your samples Separation Science Fermentation

What properties will you measure?

Flow Function Internal & Wall Friction Cohesive Strength Bulk Density

Vacuum Pump Solutions

Arching Dimensions Rat-Hole Diameter Hopper half Angle Gravity Shute Angle

What is the sample volume you intend to use?

Standard (230 cm3)

Laboratory Essentials

Small Volume (38 cm3)

Do you require any additional options?

Temperature Humidity

<1 month

What is your budget?

<$15K $15K-$25K >$25K

1 to 3 months

>3 Months

Trade Waste

How soon do you need your Flow Tester?

(this helps to determine the most suitable instrument)

Condition Monitoring

Anything else we need to know to assist you?

Personal Protection Configuration Guides

Version 0517

75

Australia - Free Call: 1800 251 799


Date: DD / MM / YYYY Contact Name:

Organisation:

Phone:

Email:

Texture Analysis Selection Guide To ensure we provide the right solution to meet your needs, please complete the following information, scan & email to us (refer back cover for details) Please briefly describe your application

Please briefly describe your samples

What test(s) do you wish to perform?

Elasticity

Yield Point

Hardness

Spreadability

Cohesiveness

Tackiness

Burst Strength

Consistency

Breaking Point

Relaxation

Fracturability

Pliability

Gel Strength

Adhesiveness

Ripeness

Firmness

Other

What current method are you using?

What load cell (force) do you require?

0.1 kg

10 kg

1.0 kg

25 kg

1.5 kg

50 kg

4.5 kg

Not Sure

What is your reason for analysis?

What is your budget?

<$20K

$20K to <$30K

>$30K

How soon do you need your analyser?

<1 month

1 to 3 months

>3 Months

(this helps to determine the most suitable instrument)

Anything else we need to know to assist you?

Version 0517

www.johnmorrisgroup.com

76


Date: DD / MM / YYYY Organisation:

Phone:

Email:

To ensure we provide the right solution to meet your needs, please complete the following information, scan & email to us (refer back cover for details) What are you wanting to analyse?

Protein

Please select one or more

Fat

Moisture

Compositional Analysis

Protein, Fat &/or Moisture Analysis Selection Guide

Physical Properties

Contact Name:

Please briefly describe your application Optical Analysers

Please briefly describe your samples How many samples do you run per day?

Separation Science

Please describe the current steps in your sample analysis

PROTEIN ANALYSIS Sample Preparation

Pre-Drying Sample

Particle Size Reduction

Fermentation

Other

Instrument Method

Kjeldahl Method

Dumas Method

Dye-Binding Method eg Anionic Dye Binding Method, Bradford Dye-Binding Method

Laboratory Essentials

Other

FAT ANALYSIS Sample Preparation

Pre-Drying Sample

Particle Size Reduction

Vacuum Pump Solutions

Spectroscopy eg Biuret Method, Lowry Method

Trade Waste

Hydrolysis Other

Instrument Method NMR

Condition Monitoring

Infrared Method

Specific Gravity (Foss-Let Method)

Total Fat by GC

Solvent Extraction Method?

Please name which method eg Randall, Goldfish, Wiley or Underwriters Tests, Soxhlet, Majonnier, Roese-Gottlieb Method, Alkaline Hydrolysis, Folch or Bligh & Dyer Extractions, CO2 Supercritical Fluid Extractions

Configuration Guides

Solvent Extraction Method?

Version 0517

77

Personal Protection

...continue on next page

Australia - Free Call: 1800 251 799


Protein, Fat &/or Moisture Analysis Selection Guide (continued)

Some specific questions if you are requiring moisture analysis?

MOISTURE ANALYSIS What is the moisture content of the samples to be tested?

Besides water, are there other volatile constituents in the sample?

What techniques are you currently using for moisture analysis? Drying Cabinet Method Microwave Dryer Halogen Moisture Analyser Karl-Fisher Method Please describe the current sample preparation steps for moisture analysis

Do you need to analyse for other parameters?

Yes (please list parameters)

What main issues are you looking to solve by considering a new method?

Time (clarify)

Besides protein, fat & moisture eg ash, fiber, etc

No

Cost (clarify) Accuracy & Reproducibility (clarify) Compliance (clarify) Other (clarify)

What is your budget?

(this helps to determine the most suitable instrument)

How soon do you need your solution?

<1 month

1 to 3 months

Anything else we need to know to assist you?

(methods you need to comply with, reason for new equipment ie replacement, labour saving, reduced running cost, etc)

Version 0517

www.johnmorrisgroup.com

78

>3 Months


Date: DD / MM / YYYY Organisation:

Phone:

Email:

To ensure we provide the right solution to meet your needs, please complete the following information, scan & email to us (refer back cover for details)

Please describe your sample(s) to be analysed

Compositional Analysis

Biochemistry Analyzer Selection Guide

Physical Properties

Contact Name:

(ie What matrix? What type of sample tube/vessel is intended to be used?)

Optical Analysers

Please list the analytes required for testing as well as any standards you need to comply with

Each chemistry will run on a module containing 2 sensors. Chemistries may require different sensor types or buffers to run properly. Use the chart opposite to select compatible chemistry pairs for each module.

Separation Science

Please choose your chemistries

Chemistry List & Compatibility Chart

Please select which First Chemistry & which it is Compatible With

Chemistries which can be run together First Chemistry

Compatible With

Ethanol

Glucose

Glutamate

Glucose

Lactate

Glucose

Galactose

Glucose Ethanol Ethanol HC Glucose Glutamate Lactate Lactose Xylose

Glutamate Choline Lactate

Glucose

Glutamine

Lactate Choline Glutamate

Ethanol

Glucose

Lactose

Glucose

Trade Waste

Chemistries which must be run together (information only - no need to select) First Chemistry

Laboratory Essentials

Glucose Choline Galactose Glycerol Sucrose

Vacuum Pump Solutions

Ethanol HC

Lactate

Fermentation

Choline

Must Be Run With

Ammonium Potassium Glutamate

Ethanol HC

Glucose

Galactose Glucose

Condition Monitoring

Ethanol

Chemistries which must be run alone (information only - no need to select)

Personal Protection

First Chemistry

Second Chemistry

Methanol None Hydrogen Peroxide

- Instrument Selection & Accessories

Version 0517

79

Australia - Free Call: 1800 251 799

Configuration Guides

‌ continued next page

None


Biochemistry Analyzer Selection Guide (continued) Select which instrument best suits your requirements Will You Measure Ammonium or Potassium? Continue to fill to Part A Below

Yes

Continue to fill to Part B Below

No

How Many Chemistries in Addition to Ammonium & Potassium Will You Measure?

A

1

Yes

CHEMISTRY

2950D-4

2

Are both chemistries module-compatible?

3

Is at least 1 pair of chemistries module-compatible?

4

Are there 2 pairs of module-compatible chemistries?

CHEMISTRY

CHEMISTRY

CHEMISTRY

Yes

2950D-4

No

2950D-3

Yes

2950D-3

No

Review

Yes

2950D-3

No

Review

Continue to the Instrument Selection Summary & Accessories at the botom of the page

B

How Many Chemistries Will You Measure?

1

Yes

CHEMISTRY

2

2950D-0

Are both chemistries module-compatible?

Yes

CHEMISTRY

3

CHEMISTRY

4

Is at least 1 pair of chemistries module-compatible?

Are there 2 pairs of module-compatible chemistries?

Are there 2 pairs of module-compatible chemistries?

6

Are there 3 pairs of module-compatible chemistries?

CHEMISTRY

2950D-0

No

2900D

No

2950D-1

Yes

2950D-1

No

2950D-2 2950D-1

Is at least 1 pair of chemistries module-compatible?

No

5

Yes

Yes

CHEMISTRY

CHEMISTRY

Are there plans to measure more?

Yes

2950D-2

No

Review

Yes

2950D-2

No

Review

Yes

2950D-2

No

Review

Instrument Selection Summary & Accessories Instrument Selection Summary

Select the accessories you require

Description

Accessory

Description

2900D

Biochemistry Analyzer with One Biosensor Module

2901

Printer

2950D-0

One Biosensor Module

2941 R24

24 place capped vial tray

2950D-1

Two Biosensor Modules

2942 P96

Flat bottom 96 well plate

2950D-2

Three Biosensor Modules

2943 P96

Round bottom 96 well plate

2950D-3

Two Biosensor & One ISE Module

2945 R24

12 mm glass vial tray

2950D-4

One Biosensor & One ISE Module

2947 R8

12 mm test tube rack

2948 R4

16 mm test tube rack

Instrument

Concerning your budget?

Is the Item Funded?

Yes

Anything else we need to know to assist you?

www.johnmorrisgroup.com

80

No (or for Budgetary Purposes

Yes

No)


Date: DD / MM / YYYY Organisation:

Phone:

Email:

Physical Properties

Contact Name:

To ensure we provide the right solution to meet your needs, please complete the following information, scan & email to us (refer back cover for details)

Please briefly describe your application

Compositional Analysis

Fiber Analysis Selection Guide (including any standards you need to comply with)

Optical Analysers Separation Science

Please describe your samples

(eg grains, plant material, animal feed, etc)

Crude Fiber

Neutral Detergent Fiber

Acid Detergent Fiber

Other

Dietary Fiber

Vacuum Pump Solutions

What current method are you using?

Are your samples wet or dry?

Fermentation

What type of fiber test(s) are you interested in?

Wet

Dry

Both

Laboratory Essentials

Number of samples per day/week?

(please state per day or week)

What is your reason for analysis?

Trade Waste

(eg regulatory/end customer compliance, R&D, etc )

<$20K

$20K to $40K

>$40K

How soon do you need your analyser?

<1 month

1 to 3 months

>3 Months

(this helps to determine the most suitable instrument)

Condition Monitoring

What is your budget?

Anything else we need to know to assist you? Personal Protection Configuration Guides

Version 0517

81

Australia - Free Call: 1800 251 799


Date: DD / MM / YYYY Contact Name:

Organisation:

Phone:

Email:

Digestion & Extraction Selection Guide To ensure we provide the right solution to meet your needs, please complete the following information, scan & email to us (refer back cover for details) Please describe your sample (composition, source, etc)

CURRENT SAMPLE PREPARATION METHOD What method are you using currently?

Microwave

Hot Plate

Soxhlet

Other (specify)

What is the sample mass? What acids or solvents are being used & volume?

Acids (specify) Volume (specify)

(mL)

Solvents (specify) Volume (specify)

(mL)

What is the final dilution/concentration? What is the current total method time? What is the analyte(s) & concentration range?

Analytes (specify) Concentration (specify)

What is your sample throughput?

Current

(samples/day) or

(samples/week)

Desired

(samples/day) or

(samples/week)

Any additional information we need to know about your current sample prep method?

CURRENT METHOD OF ANALYSIS What instrument do you use for analysis? (eg ICP-MS, GC-MS)

What volume of sample do you require for analysis? Any additional information we need to know re your current method of analysis &/or challenges?

What is your budget?

(this helps to determine the most suitable instrument)

How soon do you need your instrument?

<$25K

<1 month

$25K to <$50K

1 to 3 months

Is there anything else we need to know to assist you?

Version 0517

www.johnmorrisgroup.com

82

>$50K

>3 Months


Date: DD / MM / YYYY Organisation:

Phone:

Email:

Physical Properties

Contact Name:

To ensure we provide the right solution to meet your needs, please complete the following information, scan & email to us (refer back cover for details) Please describe the application(s) to be performed

(ie not turbid or opaque, liquid between room temp & 95°C)

Please list in detail

Yes

Is fast colour measurement critical?

Yes

No

No

Does the material require heating?

Yes

Yes

Is remote calibration & servicing via RCMSi required?

No

Will you be requiring other colour scales in the future?

Yes

Are you aware of the limits of Subjective manual v’s Absolute automatic colour measurement?

Yes

No

(clarify)

(clarify)

No

Trade Waste

(clarify)

No Yes

(clarify)

<1 month

1 to 3 months

What is your budget?

Economy

Mid-Range

>3 Months

Premium

Personal Protection

Anything else we need to know to assist you? (eg how do you perform analysis now, etc)

Configuration Guides

Version 0517

Condition Monitoring

No

How soon do you need your instrument?

(this helps to determine the most suitable instrument)

Yes

Laboratory Essentials

Yes No

(is colour blindness an issue?)

(clarify)

No

(eg Pt-Co <20 -l onger path length are required for clear solutions)

Are your technicians experienced in colour matching?

(clarify)

Vacuum Pump Solutions

(how much time should a measurement take)

Are the samples very light in colour?

(clarify)

Fermentation

Yes

Is compliance with ISO 17025 required?

(clarify)

No

If particulates are present, can liquid be filtered to produce a transparent liquid?

(in order to become liquid & hence transparent?)

Separation Science

Is the material transparent?

Optical Analysers

What colour scale(s) do you require?

Compositional Analysis

Colour Selection Guide

83

Australia - Free Call: 1800 251 799


Date: DD / MM / YYYY Contact Name:

Organisation:

Phone:

Email:

Refractometer Selection Guide To ensure we provide the right solution to meet your needs, please complete the following information, scan & email to us (refer back cover for details)

Please describe the application to be performed/ what is the sample you are measuring

Please select the use environment

Portable

Laboratory

In-Line

What units of measure will your results be displayed in?

What measuring range do you require for your refractometer?

What accuracy do you require?

Do you need automatic temperature compensation (ATC)?

Yes

No

How soon do you need your refractometer?

<2 Weeks

2 to 4 Weeks

>4 Weeks

What is your budget?

Economy

Mid-Range

Premium

(this helps to determine the most suitable instrument)

Would you be interested in a combined refractometer + polarimeter?

Yes

No

Anything else we need to know to assist you? (current process, existing brands, etc)

Version 0517

www.johnmorrisgroup.com

84


Date: DD / MM / YYYY Organisation:

Phone:

Email:

Physical Properties

Contact Name:

To ensure we provide the right solution to meet your needs, please complete the following information, scan & email to us (refer back cover for details) Please briefly describe your application/ current method

Small Molecule

Peptide

Optical Analysers

Molecule type?

Protein Nucleotides Polymer Carbohydrates Natural Products

Manual Flash Chromatography

Supercritical Fluid Chromatography

Semi-Automated Flash Chromatography

Recrystallization

Reversed Phase HPLC

Scavenger Resins

Normal Phase HPLC

Chiral HPLC

Solid Phase Extraction

Other

How many flash separations do you do per week?

Fermentation

Separation parameters?

Other

Separation Science

Current purification technique(s)?

Compositional Analysis

Purification Selection Guide

Solvent type? Sample load range (mg)? Amount of target needed to purify in a single run (mg)? What level of final purity do you need? Load technique

Vacuum Pump Solutions

Liquid - what is your dissolution solvent? Solid

How do you typically collect fractions? Manually

UV

Mass Spec

Trigger From Detector

Photodiode Array

Refractive Index

Peak

Do you collect by:

Time

Volume

All

What size cartridges do you use? 4g

12 g

330 g

750 g

40 g

80 g

120 g

1500 g

Other

Amino

Alumina

SEC

Diatomaceous Earth

220 g

Laboratory Essentials

Evaporative Light Scattering (ELSD)

What type of cartridges do you use? C18

SAX

SCX

Diol

Trade Waste

Silica

How much time are you spending isolating & purifying compounds? Isolating Purifying

Condition Monitoring

If you could change something about your current purification technique, what would it be? TLC

HPLC

UV

MS

ELSD

RI

How do you assess purity of fractions?

TLC

HPLC

UV

MS

ELSD

RI

What is your timeline to purchase?

<1 month

Concerning your budget?

1 to 4 months

Is the Item Funded?

Yes

Personal Protection

How do you assess purity of crude mixtures?

>4 months

No (or for Budgetary Purposes

Yes

No)

Configuration Guides

Anything else we need to know to assist you?

Version 0517

85

Australia - Free Call: 1800 251 799


Date: DD / MM / YYYY Contact Name:

Organisation:

Phone:

Email:

Vacuum Pump Selection Guide To ensure we provide the right solution to meet your needs, please complete the following information, scan & email to us (refer back cover for details) Please briefly describe the application(s) to be performed

What substances will be pumped?

Type of Gas

CAS No.

(optional if known)

(if you use complex substances please also add the CAS number [Chemical Abstracts Service] in addition to the name)

Information regarding process pressure

Type of Process Run

Continuous

Batch

Pressure at Given Flows/Base Pressure (please include units)

Pump Down Requirements: Starting Pressure (unit)

Target Pressure (unit)

Pump-Down Time (unit)

Information regarding chambers & pipes

Vacuum Chamber Volume (unit) Surface of Chamber (unit)

Materials

(unit)

Outgassing Rate of Materials (unit) Length of Piping (unit)

Type of project

New

Diameter of Piping

(unit)

Replacing Existing Pumps

Please Describe Your Requirements

eg pump type (fore vacuum, high vacuum), pump combination, requested pumping speeds (unit), number of pumps, requirements for Explosive Protection (please refer to Flame Proof Vacuum Pump Selection Guide)

Installation requirements

Mains Voltage (V)

Mains Frequency (Hz)

Cooling Media (water or air) Ambient Temperature (°C) System Footprint

Length (meters)

Do you have any attachments to support your requirements?

Vacuum Schematic

What is your budget?

Economy

(if yes, please select & attach)

(this helps to determine the most suitable instrument)

How soon do you need your pump?

(°C)

Width (meters)

Installation Drawing

Height (meters)

Material Safety Data Sheet

Other (specify)

Mid-Range

Is the Item Funded? <1 month

Yes

Premium No (or for Budgetary Purposes

2 to 4 months

Anything else we need to know to assist you? Version 0517

www.johnmorrisgroup.com

Intake Temperature

86

>4 Months

Yes

No)


Date: DD / MM / YYYY Organisation:

Phone:

Email:

Physical Properties

Contact Name:

To ensure we provide the right solution to meet your needs, please complete the following information, scan & email to us (refer back cover for details)

Please describe the application to be performed

ie what conditions will the pump be exposed to, chemistry of

Compositional Analysis

Peristaltic Pump Selection Guide

material (specific solution or material being pumped), etc

Optical Analysers

What flow rate do you require? Yes

mL or

%

bar

Separation Science

Will there be any back pressure/suction pressure?

Accuracy required

mL/minute

No

What is the viscosity of the solution?

Low

(eg water ≈ 1.0 cP)

Medium (eg castor oil = 1,000 cP)

Are there particulates/solids in the solution?

Yes

%

mm

No Yes

Based on Volume Dispense:

ie multiple &/or repetitive pumping of same volume or time with pauses, programed for filling bottles of containers of specified volume, etc

Approx size of particulates

Yes

What volume

mL

What accuracy

mL

Vacuum Pump Solutions

Do you need dispense program capability?

(eg honey = 10,000 cP)

Based on Time Dispense

No

Yes

No

Do you require washdown/clean room capability?

Yes

No

Calibration requirements?

Do you have a balance

Yes

No

Do you have a measuring cylinder(s)

Yes

No

Laboratory Essentials

Do you require computer compatibility? ie a computer operates the pump drive

(ie IP 66)

Trade Waste

Do you need spare tubing?

Yes

No

Do you need fittings?

Yes

(specify)

How soon do you need your pump?

<2 Weeks

2 to 4 Weeks

1 to 3 Months

What is your budget?

<$3K

$3K to $6K

$6K to $10K

No >3 Months >$10K

Condition Monitoring

(this helps to determine the most suitable instrument)

Fermentation

High

Is there anything else we need to know to assist you? Personal Protection

(is this replacing an existing pump, how many pumps do you

need, is there a wide flow range or low pulse requirement, etc)

Configuration Guides

Version 0517

87

Australia - Free Call: 1800 251 799


your needs

DESIGN a recommendation

Australia Address 61-63 Victoria Avenue Chatswood NSW 2067 Australia Free Call 1800 251 799 Enquiries +61 (0) 2 9496 4200 Email info@johnmorrisgroup.com

DELIVER the right solution

DELIGHT you throughout!

New Zealand Address 78 Wellesley Street Auckland NZ 1010 Toll Free 0800 651 700 Enquiries +64 (0) 9 366 3999 Email info@johnmorrisgroup.com

www.johnmorrisgroup.com

Whilst John Morris Group has taken every care to ensure the accuracy of information contained within this Guide, no responsibility for errors or omissions is accepted.

DEFINE ?


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.