Masterflex Peristaltic Pumps

Page 1

John Morris Scientific

John Morris Scientific Service plus Solutions


John Morris

John Morris Scientific Service plus Solutions

Scientific

Selecting the Right Equipment

Pump Drive

A peristaltic pump uses positive displacement to transfer fluids within a flexible tube fitted inside a circular casing. A rotor (with a number of rollers attached) compresses the tube and as the rotor turns, the part of the tube under compression is pinched closed forcing the fluid to be pumped through the tube - this is known as ‘occlusion’. This brochure contains an overview of the extensive range of Masterflex peristaltic pump systems.

To ensure you select the right equipment for your particular needs, follow these steps as a guide:

1

Pump Head

Define Flow Rate

Tubing

Example

Select from relevant Pump Series Flow Range

Series

Application

0.002 to 43 mL/min

C/L

Compact/Low Flow

0.001 to 3,400 mL/min

L/S

Lab/Standard

10 to 19,000 mL/min

I/P

Industrial/Process

650 to 42,000 mL/min

B/T

Batch/Transfer

2

Overview Combine low flow & compact size into a single pump Fixed & variable speed with high-accuracy Powerful & better protection from dust & water Heavy duty & ideal in manufacturing

Solution/Product to be Pumped Check the Tubing Type with tubing formulation to be pumped - refer table on page 3. Note: If options exist, refer Tubing Material Life Comparison chart to refine your selection (page 3)

3

With a desired 900 mL/min flow rate, we have a choice of L/S or I/P Pump Series - we select L/S Series as it is the most popular & designed for lab use

We choose Acetone which, based on the Tubing Type table, offers CD (Chem-Durance Bio) or PFL (Gore Style 500) tubing formulation - we select CD tubing because it has a longer life & lower price

Select Pump Drive, Pump Head & Tubing Size Pump Drive Based on L/S Series, we select Economy Consider type of head, flow rate, fixed/variable speed, number of heads, etc) - Console Pump Drive (600 rpm) as select from relevant Pump Series it satisfies flow rate, choice of variable speeds & is cheaper than I/P Pump Head Choose the Pump Head based on Tubing Formulation suitability (per Step 2) - select from relevant Pump Series Tubing Size Based on required flow rate, select the tubing size to meet your needs select from relevant Pump Series

As CD tubing formulation offers Easy Load or Easy Load II Pump Heads, we select Easy Load II as it has adjustable occlusion models We select L/S 17 as it meets our flow rate requirements

All Masterflex pumps conform to either ISO 9001:2008 or ISO 9001:2000 standards To ensure you select the right peristaltic pumping system for your needs or for servicing your equipment, simply contact John Morris Scientific for professional advice.

2

Free Call: 1800 552 724

Australia

coleparmer.johnmorris.com.au


Tubing Type Determine the right tubing formulation for your application using this compatibility table for all Masterflex tubing sizes. All ratings indicate tubing condition after exposure to the chemical at 21ᵒC.

Tubing Formulations PN PharMed BPT, High-Pressure PharMed BPT, PharmaPure, Norprene, Norprene Food, PuriFlex CF C-FLEX & C-Flex Ultra S Silicone (peroxide/ platinum-cured), BioPharm, BioPharm Plus, GORE Style 100SC T Tygon E-Lab, Tygon E-LFL, Tygon E-Food TU Tygon Fuel & Lubricant TC Tygon Chemical CD Chem-Durance Bio PFL GORE Style 500 V Viton, GORE Style 400 FP Polytetrafluoroethylene (PTFE)

Ratings

Recommended for use

Not recommended (blank)

No data available

Tubing Material Life Comparison Average life (hours) @ 50 rpm 1000

10,000

500

Norprene®, PharMed® BPT, PharmaPure®

5000

Puri-Flex™, C-Flex® ULTRA

2500

Tygon® E-LFL

150

Viton®

300 Tygon® E-Food, E-Lab

Tygon® E-Food, E-Lab

500

C-FLEX®, Silicone

Tygon® E-LFL

100

C-FLEX®, Silicone

500

200

BioPharm Plus silicone, Chem-Durance® Bio

BioPharm Plus silicone, Chem-Durance® Bio

2000

Puri-Flex™, C-Flex® ULTRA

500

300

Average life (hours) @ 50 rpm

2000

10,000

5000

® BPT, PharmaPure® Norprene®, PharMed 2500

1000

150

Viton®

100 10,000

200

10,000

The information in this brochure has been supplied by the manufacturer & is to be used as a guide only. Whilst John Morris Scientific has taken every care to ensure the accuracy of information, no responsibility for errors or omissions is accepted.

Solution/Product

Tubing Formulations PN CF S

T TU TC CD PFL V

Solution/Product FP

Acetaldehyde Acetate LMW Acetic acid <5% Acetic acid >5% Acetic anhydride Acetone Acetonitrile Acetyl bromide Acetyl chloride Air Aliphatic hydrocarbons Aluminium chloride Aluminium sulfate Alums Ammonia, gas / liquid Ammonium acetate Ammonium carbonate Ammonium chloride Ammonium hydroxide Ammonium nitrate Ammonium phosphate Ammonium sulfate Amyl acetate Amyl alcohol Amyl chloride Aniline Aniline hydrochloride Aqua regia 80% HCI, 20% H Aromatic hydrocarbons Arsenic salts Barium salts Benzaldehyde Benzenesulfonic acid Bleaching liquors Boric acid Bromine Butane Butanol (butyl alcohol) Butyl acetate Butyric acid Calcium oxide Calcium salts Carbon bisulfide Carbon dioxide Carbon tetrachloride Chlorine, dry Chlorine, wet Chloroacetic acid Chlorobenzene Chlorobromomethane Chloroform Chlorosulfonic acid Chromic acid, 30% Chromium salts Copper salts Cresol Cyclohexane Cyclohexanone Diacetone alcohol Dimethyl formamide Dimethyl Sulfoxide (DMSO) Essential oils Ethanol (ethyl alcohol) Ether Ethyl acetate Ethyl bromide Ethyl chloride Ethylamine Ethylene chlorohydrin Ethylene dichloride Ethylene glycol Ethylene oxide Fatty acids Ferric chloride Ferric sulfate Ferrous chloride Ferrous sulfate Fluoboric acid Fluoroborate salts Fluosilicic acid Formaldehyde Formic acid, 25% Freon TMS Gasoline, high-aromatic Gasoline, nonaromatic Glucose Glue, P.V.A. Glycerin Hydriodic acid Hydrobromic acid, 30% Hydrochloric acid (dil) Hydrochloric acid (med) Hydrochloric acid (conc) Hydrocyanic acid Hydrocyanic acid, gas, 10% Hydrofluoric acid, 50%

Do not use L/S PTFE Tubing Pump Head with gases due to excessive heat build-up

3

Toll Free: 0800 200 070

New Zealand

Tubing Formulations PN CF S

T TU TC CD PFL V

FP

Hydrofluoric acid, 75% Hydrogen peroxide (dil) Hydrogen peroxide, 90% Hypochlorous acid Iodine solutions Iodoform Kerosene Ketones Lacquer solvents Lactic acid, 3–10% Lead acetate Linseed oil Lithium hydroxide Magnesium chloride Magnesium sulfate Malic acid Manganese salts Mercury salts Methane Methanol (methyl alcohol) Methyl chloride Methyl ethyl ketone (MEK) Mixed acid 40% H2SO4, 15% Molybdenum disulfide Monoethanolamine Naphtha Natural gas Nickel salts Nitric acid (dil) Nitric acid (med) Nitric acid (conc) Nitrobenzene Nitrogen oxides Nitrous acid Oils, animal Oils, mineral Oils, vegetable Oleic acid Oxalic acid, cold Oxygen, gas Palmitic acid, 100% in ether Perchloric acid Perchloroethylene Phenol (carbolic acid) Phosphoric acid, 50% Phthalic acid Plating solutions Polyglycol Potassium carbonate Potassium chlorate Potassium hydroxide (med) Potassium hydroxide (conc) Potassium iodide Propanol (propyl alcohol) Pyridine Silicone fluids Silicone oils Silver nitrate Soap solutions Sodium bicarbonate Sodium bisulfate Sodium bisulfite Sodium borate Sodium carbonate Sodium chlorate Sodium chloride Sodium ferrocyanide Sodium hydrosulfite Sodium hydroxide (dil) Sodium hydroxide, 25% Sodium hydroxide (conc) Sodium hypochlorite, <5% Sodium hypochlorite, >5% Sodium nitrate Sodium silicate Sodium sulfide Sodium sulfite Steam, up to 40 psi Stearic acid Styrene Sulfuric acid (dil) Sulfuric acid (med) Sulfuric acid (conc) Sulfurous acid Tannic acid Tanning liquors Tartaric acid Tin salts Toluene (toluol) Trichloroacetic acid Trichloroethylene Trisodium phosphate Turpentine Urea Uric acid Water, fresh Water, salt Xylene Zinc chloride

coleparmer.johnmorris.co.nz


John Morris

John Morris Scientific Service plus Solutions

Scientific

C/L Pump Series

Flow Range

The Pump Drive, Pump Head and Tubing Size must be selected from the same Pump Series.

0.002 to 43 mL/min

a. C/L Pump Head Suitability with Tubing Formulations Tubing Formulation C-Flex

Suitability Temp Range

PharMed BPT

Advantages

Limitations

-40ᵒC to 60ᵒC

Physical properties similar to silicone with chemical compatibility of Tygon

-20ᵒC to 80ᵒC

Great for tissue & cell work - nontoxic & nonhemolytic

Potential leaching of USP mineral oil or blend material

Not recommended for use with hydrocarbons

Puri-Flex

-30ᵒC to 80ᵒC

Biocompatible, heat sealable & weldable

Do not use with concentrated solvents, oils or acids

Silicone (peroxide-cured)

-40ᵒC to 100ᵒC

Excellent biocompatibility

Do not use with concentrated solvents, oils or acids

Silicone (platinum-cured)

-40ᵒC to 100ᵒC

Excellent biocompatibility

Do not use with concentrated acids & bases, organic solvents or oils

Tygon E-Lab (E-3603)

0ᵒC to 40ᵒC

Inexpensive tubing for general lab applications

Limited pumping life

Tygon E-LFL

0ᵒC to 40ᵒC

Longest life of all Tygon peristaltic tubing

Do not use with strong acids or alkalies

Viton

0ᵒC to 150ᵒC

Perfect for food & lab applications (FDA compliant)

Limited pumping life

b. C/L Pump Drives Model

Flow Rate per Channel (mL/ min)

RPM

0.002 - 43

Variable 1.7 - 300

0.002 - 12.3

Variable 1.6 - 60

Number of Heads

Reversible

Portable (12 VDC)

Size (cm)

Weight (kg)

Models

1

L: 17.8 W: 8.9 H: 8.9

1.4

6

2

L: 19.9 W: 9.5 H: 8.9

1.4

4

Single Channel

Dual Channel

c. C/L Pump Tubing Size Masterflex provides a large range of C/L tubing to satisfy all requirements (internal diameters from 0.19 to 2.79 mm with a Flow Range from 0.002 to 43 mL/minute). Simply contact John Morris Scientific for further information.

4

Free Call: 1800 552 724

Australia

coleparmer.johnmorris.com.au


L/S Pump Series

Flow Range

The Pump Drive, Pump Head and Tubing Size must be selected from the same Pump Series.

0.001 to 3,400 mL/min

a. L/S Pump Head Suitability with Tubing Formulations Tubing Formulation

Standard

Pump Heads Easy-Load Easy-Load II Easy-Load 3

Multi Channel Cartridge

Temp Range High Performance (Precision)

Advantages

Limitations

BioPharm Plus Silicone (platinum-cured)

-40ᵒC to 100ᵒC

Similar to BioPharm Silicone plus longest life of any silicone tubing

Do not use with concentrated solvents, oils or acids

BioPharm Silicone (platinum-cured)

-40ᵒC to 100ᵒC

Ultra-smooth inner surface minimises particle entrapment

Do not use with concentrated solvents, oils or acids

C-Flex

-40ᵒC to 60ᵒC

Properties similar to silicone with chemical compatibility of Tygon

Not recommended for use with hydrocarbons

C-Flex ULTRA

-40ᵒC to 80ᵒC

Properties similar to silicone with chemical compatibility of Tygon

Not recommended for use with hydrocarbons

0ᵒC to 40ᵒC

Excellent chemical resistance & durability

Requires high starting torque

Chem-Durance Bio

-

-

-

GORE Style 100SC

-

-

-40ᵒC to 150ᵒC

Long life (even up to 4 bar pressure) & excellent flow stability

Sold as tube elements only

GORE Style 400

-

-

0ᵒC to 150ᵒC

Long life under pressure

Does not meet either USP or FDA classifications

GORE Style 500

-

-

-40ᵒC to 150ᵒC

Similar to STA-PURE PCS tubing but with enhanced chemical resistance

Sold as tube elements only

Norprene (A 60 G)

-20ᵒC to 80ᵒC

Best choice for vacuum/ pressure applications

Potential leaching of USP mineral oil or blend material

Norprene Food (A 60 F)

-20ᵒC to 80ᵒC

FDA approval & excellent for food/dairy

Potential leaching of USP mineral oil or blend material

-20ᵒC to 80ᵒC

Nontoxic & nonhemolytic (similar to PharMed BPT) & biocompatible

Potential leaching of USP mineral oil or blend material

-20ᵒC to 80ᵒC

Great for tissue & cell work - nontoxic & nonhemolytic

Potential leaching of USP mineral oil or blend material

-40ᵒC to 150ᵒC

Chemically inert & excellent chemical resistance

Limited pumping life & sold as tube elements only

-30ᵒC to 80ᵒC

Biocompatible & heat sealable & weldable

Do not use with concentrated solvents, oils or acids

-40ᵒC to 100ᵒC

Designed especially for handling food products

Do not use with concentrated solvents, oils or acids

-40ᵒC to 100ᵒC

Excellent biocompatibility

Do not use with concentrated acids & basis, organic solvents or oils

0ᵒC to 40ᵒC

Best chemical resistance of any Tygon formulation

Limited pumping life

Tygon E-Food (B-44-4X)

0ᵒC to 40ᵒC

Designed especially for handling food products

Limited pumping life

Tygon E-Lab (E-3603)

0ᵒC to 40ᵒC

Inexpensive tubing for general lab applications

Limited pumping life

Tygon E-LFL

0ᵒC to 40ᵒC

Longest life of all Tygon peristaltic tubing

Tygon Fuel & Lubricant (F-4040-A)

0ᵒC to 40ᵒC

Viton

0ᵒC to 150ᵒC

PharmaPure

-

-

-

-

-

PharMed BPT PTFE

-

-

-

-

-

Puri-Flex Silicone (peroxide-cured) Silicone (platinum-cured) Tygon Chemical (2001)

-

-

-

-

Specially formulated to transport hydrocarbons, petroleum products & distillates Perfect for food & lab applications (FDA compliant)

Do not use with strong acids or alkalies Do not use with strong acids or alkalies Limited pumping life

5

Toll Free: 0800 200 070

New Zealand

coleparmer.johnmorris.co.nz


John Morris

John Morris Scientific Service plus Solutions

Scientific

b. L/S Pump Drives Type

Analog

Speciality

Model

Flow Rate per Channel (mL/min)

RPM

Number of Heads

Reversible

Portable (12 VDC)

Size (cm)

Weight (kg)

Models

-

-

L: 15.2 W: 13.4 H: 11.9

2.9

7

-

L: 16.5 W: 13.3 H: 11.4

2.7

2

L: 13.6 W: 13.3 H: 11.4

1.7

2

L: 22.9 W: 18.1 H: 13.3

3.7

2

L: 25.1 W: 12.2 H: 22.4

6.0

1

Fixed Speed

0.06 - 290

Fixed 1, 2, 6, 12, 20, 30, 60

1 or 2

Compact

0.8 - 105

Variable 20 - 100

1 or 2

Stackable

2.1 - 560

Variable 35 - 200

1

Economy Console

0.42 - 2,900

Variable 7 - 200 20 - 600

1 or 2

Air-Powered

3.6 - 3,400

Variable 60 - 600

2

Samplers Portable

4.2 - 1,100

Variable 70 - 400

1

L: 27.9 W: 25.4 H: 40.6

8.7

1

Samplers Composite

1,650

Fixed 600

1

L: 28.0 W: 34.3 H: 44.4

10.9

1

DC Powered Compact

6 - 2,700

Fixed 100, 540, 570

1 or 2

L: 21.6 W: 9.7 H: 11.7

4.1

4

DC Powered Cabinet-Style

1.2 - 2,400

Variable 20 - 90 100 - 500

1 or 2

L: 27.9 W: 16.5 H: 22.2

5.3

2

Precision Console

0.06 - 3,400

Variable 1 - 100 3 - 300 6 - 600

Precision Modular

0.06 - 3,400

Variable 1 - 100 6 - 600

Digital Standard

0.001 - 3,400

Computer Compatible

-

2 or 4

-

L: 27.4 W: 21.2 H: 21.6

6.9

3

2 or 4

-

L: 27.7 W: 9.7 H: 11.7

7.1

4

Variable 0.02 - 100 0.1 - 600

2 or 4

-

L: 27.4 W: 21.2 H: 21.6

5.9

2

0.001 - 3,400

Variable 0.02 - 100 0.1 - 600

2 or 4

-

L: 27.4 W: 21.2 H: 21.6

5.9

2

Modular Dispensers

0.006 - 3,400

Variable 0.1 - 600

2

-

L: 22.7 W: 9.7 H: 12.0

7.1

2

Digital Process

0.006 - 3,400

Variable 0.1 - 600

2

-

L: 30.5 W: 22.9 H: 23.6

11.8

1

Digi-Staltic Dispenser

0.72 - 5,800

Variable 6 - 600

2

-

L: 31.7 W: 23.4 H: 18.3

13.7

2

Digital

6

Free Call: 1800 552 724

Australia

coleparmer.johnmorris.com.au


c. L/S Pump Heads

Select the appropriate pump head to complement your pumping requirements and pump features Type

Flow Rate (mL/min)

RPM (max)

Stackable

Multi Channel

Multi Channel

Standard

0.001 - 2,900

600

Up to 4 Heads

-

Precise repeatable fluid transfer

Low cost, high precision & accuracy. Best choice for dispensing applications. One head accepts one tubing size

25

Easy-Load

0.001 - 2,300

600

Up to 4 Heads

-

Easy tubing changes

Very fast tubing changes. One head accepts many tubing sizes. Change tubing without dismounting pump head from drive

8

Easy- Load II

0.001 - 2,900

600

Up to 4 Heads

-

Reduced pulsation

Same as Easy-Load (above) but with automatic tubing retention & higher flow rates. Models with adjustable occlusion

8

Easy-Load 3

0.001 - 2,900

600

Up to 4 Heads

-

Mount & stack heads without tools

Easiest tubing changes with automatic retention, same side tubing entry/exit. Mount & stack heads without tools or hardware

4

-

1 to 12 Channels

600

-

300

0.00005 - 2,300

10 - 800

Multi Channel Cartridge

0.00001 - 1,700

High Performance

0.006 - 3,400

PTFE Tubing

4mm OD Tubing 0.001 - 17 6mm OD Tubing 0.005 - 65

Multi Channel

PTFE Diaphragm

Features

Models

Synchronous flow rates

Synchronous flow rates from each channel. Cartridges snap in/out quickly for multichannel applications

4

-

Highest pump head flow rate

Accepts all high-performance precision tubing sizes. Offers highest flow rate of any L/S pump head. Tubing enters & exits same side of pump head

2

-

-

For PTFE tubing

Rigid PTFE tubing is the only wetted part. Pressure capability to 6.9 bar (100 psi)

1

600

Up to 4 Heads

Up to 32 Channels

Low pulsation

Synchronous flow from up to 32 channels without cartridges. Two-stop tubing sets are easy to load with no adjustment needed

6

400

-

-

Aggressive fluids

PTFE & borosilicate glass are the only wetted parts. Excellent for metering. Pressure capability to 6.9 bar (100 psi)

2

600

d. L/S Pump Tubing Size Masterflex provides a large range of L/S tubing to satisfy all requirements (internal diameters from 0.8 to 9.7 mm with a Flow Range from 0.001 to 3,400 mL/minute) - refer page 11 for pump tubing size guide. Simply contact John Morris Scientific for further information.

7

Toll Free: 0800 200 070

New Zealand

coleparmer.johnmorris.co.nz


John Morris

John Morris Scientific Service plus Solutions

Scientific

I/P Pump Series The Pump Drive, Pump Head and Tubing Size must be selected from the same Pump Series.

a. I/P Pump Head Suitability with Tubing Formulations Tubing Formulation

Pump Heads Standard

Temp Range

High Easy-Load Performance

Advantages

Flow Range 10 to 19,000 mL/min

Limitations

BioPharm Plus Silicone (platinum-cured)

-40ᵒC to 100ᵒC

Similar to BioPharm Silicone plus longest life of any silicone tubing

Do not use with concentrated solvents, oils or acids

BioPharm Silicone (platinum-cured)

-40ᵒC to 100ᵒC

Ultra-smooth inner surface minimises particle entrapment

Do not use with concentrated solvents, oils or acids

C-Flex

-40ᵒC to 60ᵒC

Physical properties similar to silicone with chemical compatibility of Tygon

Not recommended for use with hydrocarbons

C-Flex ULTRA

-40ᵒC to 80ᵒC

Physical properties similar to silicone with chemical compatibility of Tygon

Not recommended for use with hydrocarbons

0ᵒC to 40ᵒC

Excellent chemical resistance & durability

Requires high starting torque

-40ᵒC to 150ᵒC

Long life (even under pressures up to 4 bar) & excellent flow stability

Sold as tube elements only

GORE Style 400

0ᵒC to 150ᵒC

Long life under pressure

Does not meet either USP or FDA classifications

GORE Style 500

-40ᵒC to 150ᵒC

Similar to STA-PURE PCS tubing but with enhanced chemical resistance

Sold as tube elements only

Norprene (A 60 G)

-20ᵒC to 80ᵒC

Best choice for vacuum/pressure applications

Potential leaching of USP mineral oil or blend material

Norprene Food (A 60 F)

-20ᵒC to 80ᵒC

FDA approval & excellent for food/dairy

Potential leaching of USP mineral oil or blend material

-20ᵒC to 80ᵒC

Nontoxic & nonhemolytic (similar to PharMed BPT) & biocompatible

Potential leaching of USP mineral oil or blend material

-20ᵒC to 80ᵒC

Great for tissue & cell work - nontoxic & nonhemolytic

Potential leaching of USP mineral oil or blend material

-40ᵒC to 150ᵒC

Chemically inert & excellent chemical resistance

Limited pumping life & sold as tube elements only

Puri-Flex

-30ᵒC to 80ᵒC

Biocompatible & heat sealable & weldable

Do not use with concentrated solvents, oils or acids

Silicone (peroxide-cured)

-40ᵒC to 100ᵒC

Excellent biocompatibility

Do not use with concentrated solvents, oils or acids

Silicone (platinum-cured)

-40ᵒC to 100ᵒC

Excellent biocompatibility

Do not use with concentrated acids & bases, organic solvents or oils

0ᵒC to 40ᵒC

Best chemical resistance of any Tygon formulation

Limited pumping life

Tygon E-Food (B-44-4X)

0ᵒC to 40ᵒC

Designed especially for handling food products

Limited pumping life

Tygon E-Lab (E-3603)

0ᵒC to 40ᵒC

Inexpensive tubing for general lab applications

Limited pumping life

Tygon E-LFL

0ᵒC to 40ᵒC

Longest life of all Tygon peristaltic tubing

Do not use with strong acids or alkalies

Tygon Fuel & Lubricant (F-4040-A)

0ᵒC to 40ᵒC

Specially formulated to transport hydrocarbons, petroleum products & distillates

Do not use with strong acids or alkalies

Viton

0ᵒC to 150ᵒC

Perfect for food & lab applications (FDA compliant)

Chem-Durance Bio

-

GORE Style 100SC

PharmaPure

-

PharMed BPT PTFE

Tygon Chemical (2001)

-

-

-

-

Limited pumping life

8

Free Call: 1800 552 724

Australia

coleparmer.johnmorris.com.au


b. I/P Pump Drives

Flow Rate per Channel (mL/min)

RPM

Number of Heads

Modular

36.0 - 19,000

Variable 6 - 650

Brushless Process

200 - 19,000

Modular Dispensing

Model

Type

Digital

Speciality

Reversible

Size (cm)

Weight (kg)

Models

2

L: 35.3 W: 13.9 H: 15.6

9.9

2

Variable 33 - 650

2

L: 35.0 W: 25.0 H: 23.0

10.0

1

0.6 - 19,000

Variable 0.1 - 650

2

L: 36.2 W: 17.8 H: 16.5

12.6

2

Digital Process

0.6 - 19,000

Variable 0.1 - 650

2

L: 42.3 W: 28.3 H: 32.8

18.1

2

Air Powered

600 - 19,000

Variable 100 - 650

2

L: 28.2 W: 21.6 H: 22.9

9.6

1

Fixed Speed & Multi Channel

500 - 14,100

Fixed 83, 100, 450, 540

2

L: 43.0 W: 27.6 H: 26.1

19.0

4

-

Flow rates and features are dependent upon motor selection (contact John Morris Scientific for more details)

Pump Head Adaptors

c. I/P Pump Heads Select the appropriate pump head to complement your pumping requirements and pump features Type

Standard

Easy-Load

High Performance

Flow Rate (mL/min)

RPM (max)

10 - 13,000

650

Up to 2 Heads

650

Up to 2 Heads

10 - 13,000

10 - 19,000

Stackable

650

Multi Channel

-

Usage

Features

Models

Yes

Precise repeatable fluid transfer

Low cost, high precision & accuracy. Best choice for dispensing applications. One head accepts one tubing size

6

Yes

Easy tubing changes

Quick tubing changes. One head accepts several tubing sizes. Change tubing without dismounting pump head from drive. Model available for ATEX Zone 2 applications.

4

-

Highest pump head flow rate

Accepts all high-performance precision tubing sizes. Offers highest flow rate of any I/P pump head. Tubing enters & exits same side of pump head. Model available for ATEX Zone 2 applications.

2

d. I/P Pump Tubing Size Masterflex provides a large range of I/P tubing to satisfy all requirements (internal diameters from 6.4 to 15.88 mm & Flow Range from 10 to 19,000 mL/minute) - refer page 11 for pump tubing size guide. Simply contact John Morris Scientific for further information.

9

Toll Free: 0800 200 070

New Zealand

coleparmer.johnmorris.co.nz


John Morris

John Morris Scientific Service plus Solutions

Scientific

B/T Pump Series

Flow Range

The Pump Drive, Pump Head and Tubing Size must be selected from the same Pump Series.

650 to 42,000 mL/min

a. B/T Pump Head Suitability with Tubing Formulations Tubing Formulation BioPharm Plus Silicone (platinum-cured) C-Flex

Suitability Temp Range

Advantages

Limitations

-40ᵒC to 100ᵒC

Similar to BioPharm Silicone plus longest life of any silicone tubing

Do not use with concentrated solvents, oils or acids

-40ᵒC to 60ᵒC

Physical properties similar to silicone with chemical compatibility of Tygon

Not recommended for use with hydrocarbons

Chem-Durance Bio

0ᵒC to 40ᵒC

Excellent chemical resistance and durability

Requires high starting torque

GORE Style 100SC

-40ᵒC to 150ᵒC

Long life (even under pressures up to 4 bar) & excellent flow stability

GORE Style 400

0ᵒC to 150ᵒC

Long life under pressure

Does not meet either USP or FDA classifications

Norprene (A 60 G)

-20ᵒC to 80ᵒC

Best choice for vacuum/pressure applications

Potential leaching of USP mineral oil or blend material

PharmaPure

-20ᵒC to 80ᵒC

Nontoxic & nonhemolytic (similar to PharMed BPT) & biocompatible

Potential leaching of USP mineral oil or blend material

PharMed BPT

-20ᵒC to 80ᵒC

Great for tissue & cell work - nontoxic & nonhemolytic

Potential leaching of USP mineral oil or blend material

Puri-Flex

-30ᵒC to 80ᵒC

Biocompatible & heat sealable & weldable

Do not use with concentrated solvents, oils or acids

Silicone (peroxide-cured)

-40ᵒC to 100ᵒC

Excellent biocompatibility

Do not use with concentrated solvents, oils or acids

Silicone (platinum-cured)

-40ᵒC to 100ᵒC

Excellent biocompatibility

Do not use with concentrated acids & bases, organic solvents or oils

Tygon E-Food (B-44-4X)

0ᵒC to 40ᵒC

Designed especially for handling food products

Limited pumping life

Tygon E-Lab (E-3603)

0ᵒC to 40ᵒC

Inexpensive tubing for general lab applications

Limited pumping life

Tygon E-LFL

0ᵒC to 40ᵒC

Longest life of all Tygon peristaltic tubing

Do not use with strong acids or alkalies

Sold as tube elements only

b. B/T Pump Heads & Drives Select the appropriate pump head to complement your pumping requirements and pump features Type

Model

Flow Rate per Channel (mL/min)

RPM

Number of Heads

35,000

Fixed 271

1

Variable Speed*

710 - 42,000

Variable 12 - 321

Modular Dispensing*

650 - 42,000 2,100 - 42,000

Fixed Speed*

Analog

Digital

Air-Powered*

Speciality

Rapid Load Pump Heads

Reversible

Weight (kg)

Models

L: 68.6 W: 40.0 H: 38.4

39.9

1

1

L: 68.6 W: 40.0 H: 42.4

40.4

1

Variable 11 - 321

1

L: 68.6 W: 40.0 H: 38.4

44.7

1

Variable 35 - 321

1

L: 68.6 W: 40.0 H: 42.4

40.4

1

L: 68.6 W: 40.0 H: 38.4

28.5

4

Flow rates & features are dependent upon motor selection (contact John Morris Scientific for more details)

-

Size (cm)

* Pump Head is included in each Pump Drive

c. B/T Pump Tubing Size Masterflex provides a large range of B/T tubing to satisfy all requirements (Internal Diameters from 12.7 to 19.0 mm and Flow Range from 650 to 42,000 mL/minute) - refer page 11 for pump tubing size guide. Simply contact John Morris Scientific for further information.

10

Free Call: 1800 552 724

Australia

coleparmer.johnmorris.com.au


Pump Tubing Size Guide per Pump Series L/S Pump Tubing Tubing Cross Section Precision Model Number

L/S 13

L/S 14

L/S 16

L/S 25

L/S 17

L/S 18

Inside Diameter

0.8mm

1.6mm

3.1mm

4.8mm

6.4mm

7.9mm

Tubing Cross Section - High Performance Model Number

L/S 15

L/S 24

L/S 35

L/S 36

Inside Diameter

4.8mm

6.4mm

7.9mm

9.7mm

I/P Pump Tubing Tubing Cross Section Precision Model Number Inside Diameter

I/P 26

I/P 73

I/P 82

6.4mm

9.5mm

12.7mm

Tubing Cross Section - High Performance

Model Number

I/P 70

I/P 88

I/P 89

Inside Diameter

9.5mm

12.7mm

15.88mm

B/T Pump Tubing

Tubing Cross Section

Model Number Inside Diameter

B/T 87

B/T 91

12.7mm

19.0mm

Accessories John Morris Scientific also offers an extensive range of Masterflex Peristaltic Pumping System accessories & spare parts.

Repairs & Maintenance Our Instrument Services Division provides a choice of Service Agreements to suit your needs & performs routine maintenance & repairs on all Masterflex Peristaltic Pumping Systems to ensure your equipment is operating to its optimum capacity. To ensure you select the right peristaltic pumping system for your needs or for servicing your equipment, simply contact John Morris Scientific for professional advice.

11

Toll Free: 0800 200 070

New Zealand

coleparmer.johnmorris.co.nz


We offer more than 'just the box' Solutions

Sales

Service

Support

At John Morris Scientific we offer more than just the product - we provide the full package sales and servicing of instrumentation plus design tailored solutions to meet your needs.

John Morris Scientific

John Morris Scientific Service plus Solutions Australia Address Free Call Enquiries Email Web

61-63 Victoria Avenue Chatswood NSW 2067 Australia 1800 552 724 +61 (0) 2 9496 4200 cpinfo@johnmorris.com.au coleparmer.johnmorris.com.au

New Zealand Address Toll Free Enquiries Email Web

78 Wellesley Street Auckland NZ 1010 0800 200 070 +64 (0) 9 366 3999 cpinfo@jms.co.nz coleparmer.johnmorris.co.nz

For Over 50 Years


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.