Merck Water Purification Summary

Page 1

Water Purification Selection Guide

www.johnmorrisgroup.com


Our portfolio of water purification systems include a broad range of ultrapure, pure & Reverse Osmosis (RO) water designed for all labs (in both validated & non-validated environments). To ensure you select the right instrument, follow these steps: Define the suitable applications of use (this identifies the level of purity & ‘type’ of water required) Establish the initial source of water to be purified (ie from a tap or pure water) Determine how much water you need (litres per day or hour)

Applications by Water ‘Type’ Applications

Water ‘Type’ 1

2

3

AA (Atomic Absorption) - Animal Care Facilities - Animal Watering - - Aquariums - - Autoclaves - - Blotting (Northern, Western, Southern) - BOD (Biological Oxygen Demand) - Buffers Preparation Capillary Electrophoresis - Cell Culture Media & Buffers - Clinical and Biomedical Laboratories COD (Chemical Oxygen Demand) - Colorimetric Tests & Measures DHPLC - Dissolution Testing DNA Sequencing - DNA Sequencers - Electrophoresis - Endocrine Disruptors Analysis - Fuel Cells - GC (Gas Chromatography) - GFAA (Graphite Furnace Atomic Absorption) - Glassware Washing / Washers - Heating Baths (water for) - - Histology HPLC (High Performance Liquid Chromatography) - Hydrogen Generators - -

Water ‘Type’

Applications

1

2

‘Types’ of Water Purification Type 1

Type 2

Type 3

Ultrapure Water

Pure Grade Water

Pure Grade General Lab

Highest grade of water purification - suitable for critical lab applications Resistivity (MΩ.cm @ 25°C) TOC ppb (µg/L) Pyrogens (EU/mL) Particulates >0.2 µm (units/mL) Silica (ppb) Bacteria (cfu/mL)

* With BioPak Polisher as Application Pak Water specifications are guidelines only

www.johnmorrisgroup.com

3

Hydroponics IC (Ion Chromatography) - ICP-MS & ICP-OES - In Vitro Fertilization (IVF) - Kjeldahl Analyser - Langmuir Monolayer Analysis - LC (Liquid Chromatography) - LC-MS - Lithography - - Microarray - Microbiological Culture Media Preparation - NP Analysers (Nitrogen-Phosphorus Analysers) Nuclease-Free Water / RNase-Free Water - Particulate Analysers - PCR (Polymerase Chain Reaction) - pH Measure - Semiconductors - Spectrophotometry - Stability Test Chambers - Titration TOC Analysers (Total Oxidisable Carbon) - Turbidimeter UHPLC (Ultra HPLC) - VOC (Volatile Organics Analysis) - Weatherometers - -

Very low organic contaminants - suitable for general lab needs or to feed Type 1 water

>18 <10 <0.03* <1 <10 <1

>1.0 <50 n/a n/a <10 <100

For adherence to strict quality IQ/OQ standards (where validation & recording of data is essential)

RO water suitable for non-critical applications or to feed Type 1 water >0.05 <200 n/a n/a <1,000 <1,000

For greater choice & flexibility in supplying daily water requirements for various usage applications

2


Instrument Summary Required Water Purity

Type 1 & 2 Combined Type 1 & 3 Combined

Type 1

Water Source

Resistivity (MΩ.cm @ 25°C)

Water Flow Rate L/day Max

L/min Max

TOC ppb (µg/L)

<30

2

18.2

≤5

4

<0.1

Milli-Q Direct

4

Ultrapure

Tap

Pure (RO)

Tap

Ultrapure

Pure

250

2.0

18.2

≤5

<0.1

Milli-Q Advantage A10

5

Ultrapure

Pure

200

2.0

18.2

≤5

<0.1

Milli-Q Reference / A+

5

Ultrapure

Pure

10

>0.5

18.2

≤5

<0.1

Simplicity

5

Ultrapure

Pure

12,000

12

18.2

<20

<10

Super-Q Plus

5

Pure

Tap

300

2.0

>5

<30

<0.1

Elix Advantage

6

Pure

Tap

300

Gravity Fed

>5

<30

<10

Elix Essential

6

Pure

Tap

300

Gravity Fed

>5

<30

<10

Elix Reference

6

RO

Tap

8,000

0.4

<10

RiOs Systems

7

Tap

3,000

4

<0.1

AFS Systems

7

Biomedical Water

>5

Milli-Q Integral

Tap

Type 3 (RO)

2.0

<0.1

Pure (DI)

Type 2 (DI)

<5

Page

Tap

250

18.2

Suitable Product

Ultrapure

360

2.0

Bacteria (cfu/mL)

15

Typical Rejection >99%

Typical Rejection >99% 10

TOC: Total Organic Carbon (water quality measurement - level of carbon present in organic compounds)

<30 ppb: parts per billion

DI: Deionized Water

RO: Reverse Osmosis

To ensure you select the right water purification instrument for your needs, contact John Morris Group for professional assistance Sales

Australia - Free Call: 1800 251 799

Consumables

Accessories

3

Service & Repair

New Zealand - Toll Free: 0800 651 700


Ultrapure & Pure Water from the Tap Type 1 & 2 Water - combined in one unit

Ultrapure water (Type 1) dispensed via up to 3 Q-PODs Pure water (Type 2) dispensed via E-POD Manual or automatic water delivery (with high or low flow) I/Q & OQ validation - exact water quality assured TOC monitor Application Paks to remove specific contaminants

Milli-Q Integral

Type 1 & 3 Water - combined in one unit

Ultrapure water (Type 1) dispensed via Q-POD Type 3 (RO) pure water sourced either through tank valve or to feed instruments (such as a glassware washing machine) I/Q & OQ validation - exact water quality assured Up to 350 L reservoir tank Application Paks to remove specific contaminants

Milli-Q Direct

www.johnmorrisgroup.com

4


Ultrapure Water from Pure Water Type 1 Water

Ultrapure water (Type 1) dispensed via up to 3 Q-PODs TOC & resistivity monitoring Internal UV lamp for low TOC Type 1 Application Paks to remove specific contaminants Compact - place under the bench or on the wall

Milli-Q Advantage A10

Type 1 Water

Milli-Q Reference / A+

Q-POD dispenses water (optional) Application Paks to remove specific contaminants TOC indicator included with Milli-Q Reference A+

Australia - Free Call: 1800 251 799

Type 1 Water

Type 1 Water

Simplicity

A portable & basic solution place anywhere in the lab Integrated reservoir Recirculates water to maintain quality

5

Super-Q Plus

A high-flow water system providing the ‘final polish’ to RO, distillation or deionization water No degrading of water quality over time

New Zealand - Toll Free: 0800 651 700


Pure Water from Tap Water State-of-the-art electrodeionization technology ensures delivery of constant & reliable Type 2 water replaces chemical regeneration of conventional ion-exchange systems plus removes chemical or resin disposal needs Elix systems provide the best feed water for all Milli-Q ultrapure systems

Type 2 Water

Pure water dispensed via up to 3 E-PODs I/Q & OQ validation - exact water quality assured Compact - place anywhere in the lab Application Paks to remove specific contaminants

Elix Advantage

Type 2 Water

Elix Essential

Intelligent RO controls water consumption Constant product flow rate & optimal water quality

www.johnmorrisgroup.com

Type 2 Water

Elix Reference

Pure water stored in a tank Water sourced via valve or fed directly to lab instruments

6


RO Water from Tap Water RiOs systems are suitable for reliable, constant production of Reverse Osmosis (RO) water

Biomedical Water Solutions Significantly reduce water consumption - ideal where sample throughput often greater than several thousand samples per day

RiOs Systems

Ideal for non-critical lab applications (glassware rinsing, hydroponics, water baths) Feed water for humidifiers, autoclaves, glassware washers & ultrapure water systems Choose models from 5 to 200 L

AFS Systems

Provides superior & consistent water quality Complies with clinical laboratory reagent water (CLRW) guidelines Choose models from 8 to 150 L/h flow rates Full monitoring & water quality archiving capabilities

Application Pak Polishers Application Pak polishers can be added to PODs to remove specific contaminants that impact specific applications (HPLC, LC-MS, MALDI-ToF-MS, IC, ICP, AA & most analytical techniques) Bacteria-free & particulate-free water

Pyrogen-free & nuclease-free water

Water for ultra-trace organic analysis

Water for volatile organic compounds analysis

Water for endocrine disrupters experiments

MilliPak Polisher

BioPak Polisher

LC-Pak Polisher

VOC-Pak Polisher

EDS-Pak Polisher

Best-in-Class Elix速 EDI Technology Elix速 EDI module uses electrodeionization to remove remaining ions - included in all Elix (Type 2) systems plus Milli-Q Integral (Type 1)

Consistent high-quality water - resins do not degrade (as no expose to harsh regeneration chemicals or removed from the system) No extra softeners needed Minimal electricity consumption - uses equivalent of electric light bulb energy Uninterrupted water production - continuously regenerated ion-exchange resins eliminate hazardous chemical regeneration or costly resin replacement

Australia - Free Call: 1800 251 799

7

New Zealand - Toll Free: 0800 651 700


Solutions

Sales

Service

Support

At John Morris Group we offer more than just the product - we provide the full package sales and servicing of instrumentation plus design tailored solutions to meet your needs.

Australia

New Zealand

Address 61-63 Victoria Avenue Chatswood NSW 2067 Australia Free Call 1800 251 799 Enquiries +61 (0) 2 9496 4200 Email info@johnmorris.com.au

Address 78 Wellesley Street Auckland NZ 1010 Toll Free 0800 651 700 Enquiries +64 (0) 9 366 3999 Email info@jms.co.nz

www.johnmorrisgroup.com

Whilst John Morris Group has taken every care to ensure the accuracy of information contained within this Guide, no responsibility for errors or omissions is accepted.

We offer more than 'just the box'


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.