Water Purification Selection Guide
www.johnmorrisgroup.com
Our portfolio of water purification systems include a broad range of ultrapure, pure & Reverse Osmosis (RO) water designed for all labs (in both validated & non-validated environments). To ensure you select the right instrument, follow these steps: Define the suitable applications of use (this identifies the level of purity & ‘type’ of water required) Establish the initial source of water to be purified (ie from a tap or pure water) Determine how much water you need (litres per day or hour)
Applications by Water ‘Type’ Applications
Water ‘Type’ 1
2
3
AA (Atomic Absorption) - Animal Care Facilities - Animal Watering - - Aquariums - - Autoclaves - - Blotting (Northern, Western, Southern) - BOD (Biological Oxygen Demand) - Buffers Preparation Capillary Electrophoresis - Cell Culture Media & Buffers - Clinical and Biomedical Laboratories COD (Chemical Oxygen Demand) - Colorimetric Tests & Measures DHPLC - Dissolution Testing DNA Sequencing - DNA Sequencers - Electrophoresis - Endocrine Disruptors Analysis - Fuel Cells - GC (Gas Chromatography) - GFAA (Graphite Furnace Atomic Absorption) - Glassware Washing / Washers - Heating Baths (water for) - - Histology HPLC (High Performance Liquid Chromatography) - Hydrogen Generators - -
Water ‘Type’
Applications
1
2
‘Types’ of Water Purification Type 1
Type 2
Type 3
Ultrapure Water
Pure Grade Water
Pure Grade General Lab
Highest grade of water purification - suitable for critical lab applications Resistivity (MΩ.cm @ 25°C) TOC ppb (µg/L) Pyrogens (EU/mL) Particulates >0.2 µm (units/mL) Silica (ppb) Bacteria (cfu/mL)
* With BioPak Polisher as Application Pak Water specifications are guidelines only
www.johnmorrisgroup.com
3
Hydroponics IC (Ion Chromatography) - ICP-MS & ICP-OES - In Vitro Fertilization (IVF) - Kjeldahl Analyser - Langmuir Monolayer Analysis - LC (Liquid Chromatography) - LC-MS - Lithography - - Microarray - Microbiological Culture Media Preparation - NP Analysers (Nitrogen-Phosphorus Analysers) Nuclease-Free Water / RNase-Free Water - Particulate Analysers - PCR (Polymerase Chain Reaction) - pH Measure - Semiconductors - Spectrophotometry - Stability Test Chambers - Titration TOC Analysers (Total Oxidisable Carbon) - Turbidimeter UHPLC (Ultra HPLC) - VOC (Volatile Organics Analysis) - Weatherometers - -
Very low organic contaminants - suitable for general lab needs or to feed Type 1 water
>18 <10 <0.03* <1 <10 <1
>1.0 <50 n/a n/a <10 <100
For adherence to strict quality IQ/OQ standards (where validation & recording of data is essential)
RO water suitable for non-critical applications or to feed Type 1 water >0.05 <200 n/a n/a <1,000 <1,000
For greater choice & flexibility in supplying daily water requirements for various usage applications
2
Instrument Summary Required Water Purity
Type 1 & 2 Combined Type 1 & 3 Combined
Type 1
Water Source
Resistivity (MΩ.cm @ 25°C)
Water Flow Rate L/day Max
L/min Max
TOC ppb (µg/L)
<30
2
18.2
≤5
4
<0.1
Milli-Q Direct
4
Ultrapure
Tap
Pure (RO)
Tap
Ultrapure
Pure
250
2.0
18.2
≤5
<0.1
Milli-Q Advantage A10
5
Ultrapure
Pure
200
2.0
18.2
≤5
<0.1
Milli-Q Reference / A+
5
Ultrapure
Pure
10
>0.5
18.2
≤5
<0.1
Simplicity
5
Ultrapure
Pure
12,000
12
18.2
<20
<10
Super-Q Plus
5
Pure
Tap
300
2.0
>5
<30
<0.1
Elix Advantage
6
Pure
Tap
300
Gravity Fed
>5
<30
<10
Elix Essential
6
Pure
Tap
300
Gravity Fed
>5
<30
<10
Elix Reference
6
RO
Tap
8,000
0.4
<10
RiOs Systems
7
Tap
3,000
4
<0.1
AFS Systems
7
Biomedical Water
>5
Milli-Q Integral
Tap
Type 3 (RO)
2.0
<0.1
Pure (DI)
Type 2 (DI)
<5
Page
Tap
250
18.2
Suitable Product
Ultrapure
360
2.0
Bacteria (cfu/mL)
15
Typical Rejection >99%
Typical Rejection >99% 10
TOC: Total Organic Carbon (water quality measurement - level of carbon present in organic compounds)
<30 ppb: parts per billion
DI: Deionized Water
RO: Reverse Osmosis
To ensure you select the right water purification instrument for your needs, contact John Morris Group for professional assistance Sales
Australia - Free Call: 1800 251 799
Consumables
Accessories
3
Service & Repair
New Zealand - Toll Free: 0800 651 700
Ultrapure & Pure Water from the Tap Type 1 & 2 Water - combined in one unit
Ultrapure water (Type 1) dispensed via up to 3 Q-PODs Pure water (Type 2) dispensed via E-POD Manual or automatic water delivery (with high or low flow) I/Q & OQ validation - exact water quality assured TOC monitor Application Paks to remove specific contaminants
Milli-Q Integral
Type 1 & 3 Water - combined in one unit
Ultrapure water (Type 1) dispensed via Q-POD Type 3 (RO) pure water sourced either through tank valve or to feed instruments (such as a glassware washing machine) I/Q & OQ validation - exact water quality assured Up to 350 L reservoir tank Application Paks to remove specific contaminants
Milli-Q Direct
www.johnmorrisgroup.com
4
Ultrapure Water from Pure Water Type 1 Water
Ultrapure water (Type 1) dispensed via up to 3 Q-PODs TOC & resistivity monitoring Internal UV lamp for low TOC Type 1 Application Paks to remove specific contaminants Compact - place under the bench or on the wall
Milli-Q Advantage A10
Type 1 Water
Milli-Q Reference / A+
Q-POD dispenses water (optional) Application Paks to remove specific contaminants TOC indicator included with Milli-Q Reference A+
Australia - Free Call: 1800 251 799
Type 1 Water
Type 1 Water
Simplicity
A portable & basic solution place anywhere in the lab Integrated reservoir Recirculates water to maintain quality
5
Super-Q Plus
A high-flow water system providing the â&#x20AC;&#x2DC;final polishâ&#x20AC;&#x2122; to RO, distillation or deionization water No degrading of water quality over time
New Zealand - Toll Free: 0800 651 700
Pure Water from Tap Water State-of-the-art electrodeionization technology ensures delivery of constant & reliable Type 2 water replaces chemical regeneration of conventional ion-exchange systems plus removes chemical or resin disposal needs Elix systems provide the best feed water for all Milli-Q ultrapure systems
Type 2 Water
Pure water dispensed via up to 3 E-PODs I/Q & OQ validation - exact water quality assured Compact - place anywhere in the lab Application Paks to remove specific contaminants
Elix Advantage
Type 2 Water
Elix Essential
Intelligent RO controls water consumption Constant product flow rate & optimal water quality
www.johnmorrisgroup.com
Type 2 Water
Elix Reference
Pure water stored in a tank Water sourced via valve or fed directly to lab instruments
6
RO Water from Tap Water RiOs systems are suitable for reliable, constant production of Reverse Osmosis (RO) water
Biomedical Water Solutions Significantly reduce water consumption - ideal where sample throughput often greater than several thousand samples per day
RiOs Systems
Ideal for non-critical lab applications (glassware rinsing, hydroponics, water baths) Feed water for humidifiers, autoclaves, glassware washers & ultrapure water systems Choose models from 5 to 200 L
AFS Systems
Provides superior & consistent water quality Complies with clinical laboratory reagent water (CLRW) guidelines Choose models from 8 to 150 L/h flow rates Full monitoring & water quality archiving capabilities
Application Pak Polishers Application Pak polishers can be added to PODs to remove specific contaminants that impact specific applications (HPLC, LC-MS, MALDI-ToF-MS, IC, ICP, AA & most analytical techniques) Bacteria-free & particulate-free water
Pyrogen-free & nuclease-free water
Water for ultra-trace organic analysis
Water for volatile organic compounds analysis
Water for endocrine disrupters experiments
MilliPak Polisher
BioPak Polisher
LC-Pak Polisher
VOC-Pak Polisher
EDS-Pak Polisher
Best-in-Class Elix速 EDI Technology Elix速 EDI module uses electrodeionization to remove remaining ions - included in all Elix (Type 2) systems plus Milli-Q Integral (Type 1)
Consistent high-quality water - resins do not degrade (as no expose to harsh regeneration chemicals or removed from the system) No extra softeners needed Minimal electricity consumption - uses equivalent of electric light bulb energy Uninterrupted water production - continuously regenerated ion-exchange resins eliminate hazardous chemical regeneration or costly resin replacement
Australia - Free Call: 1800 251 799
7
New Zealand - Toll Free: 0800 651 700
Solutions
Sales
Service
Support
At John Morris Group we offer more than just the product - we provide the full package sales and servicing of instrumentation plus design tailored solutions to meet your needs.
Australia
New Zealand
Address 61-63 Victoria Avenue Chatswood NSW 2067 Australia Free Call 1800 251 799 Enquiries +61 (0) 2 9496 4200 Email info@johnmorris.com.au
Address 78 Wellesley Street Auckland NZ 1010 Toll Free 0800 651 700 Enquiries +64 (0) 9 366 3999 Email info@jms.co.nz
www.johnmorrisgroup.com
Whilst John Morris Group has taken every care to ensure the accuracy of information contained within this Guide, no responsibility for errors or omissions is accepted.
We offer more than 'just the box'