COVID Triage Tent

Page 1

Sheet List

JORDAN YARNELL SPRING 2020

A001 A101 A102 A103 A104 A105 A106 A107 A108 A109 A110 A111

Sheet Name COVER PAGE EXISTING SITE PLAN PROPOSED SITE PLAN MODULE FLOOR PLAN SECTION & ELEVATION STRUCTURAL PLAN FOUNDATION PLAN TENTACLE DETAILS COMMAND CENTER DETAILS DETAILS AXONOMETRIC RENDERINGS

SCHOOL OF ARCHITECTURE & DESIGN

St Joe's Triage Tents 77 N Airlite Street Elgin, IL 60124

COVID-19 TRIAGE TENT

Sheet Number

ARCH 509

COVER PAGE

May 13, 2020

DATE

A001



DESIGN PROCESS

*I CHOSE THE FIRST MODULE TO BEGIN TO MAKE FLOOR PLANS, I FELT IT SERVED THE GREATEST PURPOSE AND WAS MOST LOGICAL AND COULD EASILY BE MANIPULATED ON OTHER SITES TO MANEUVER AROUND OBSTACLES SUCH AS PONDS AND TREES.

THE GOAL OF THIS TRIAGE TENT IS TO CREATE A MODULAR ELEMENT THAT MAXIMIZES SPACE BUT CAN SEPARATE COVID PATIENTS BASED ON SEVERITY OF ILLNESS. THE GREEN CIRCLE INDICATES IDEAL BUILDING FOOTPRINT SIZE.

BASED OFF OF THE CHOSEN MODULE, I CREATED VARIOUS FLOOR PLANS THAT DISPLAYED HOW MANY BAYS EACH MODULE COULD HOLD. I DISCOVERED THAT 26’ IS THE MINIMUM WIDTH NEEDED.

SINCE THE GOAL OF THE PROJECT WAS TO MAXIMIZE SPACE, I WENT BACK TO THE DRAWING BOARDS TO CREATE A MODULE WITH MINIMAL NEGATIVE SPACE AND WAS MORE INTRIGUING TO THE ARTISTIC EYE.

AFTER A FEW MODIFICATIONS, I CREATED A MODULE THAT HAD LITTLE NEGATIVE SPACE, WAS ABLE TO FIT AN 8’ WIDE ISLE, AND 9’ DEEP BAYS ON EITHER SIDE. THE SPIRE ALLOWS FOR ADAPTABILITY TO SITE AND ADDITION OF ROADS

EACH MODULE REQUIRED: BAYS FOR PATIENTS, COMPUTER DOCKING STATION, A CHANGING ROOM, MEDICINE CLOSET, STORAGE, CONFERENCE AREA FOR DOCTORS, HAND WASHING STATION, DESKTOP AREA FOR WORK, AND EMERGENCY EXIT/ENTRANCE FOR AMBULANCES.

ONCE I BEGAN TO ARRAY THE MODULE, I FIGURED OUT THAT SINCE THEY ARE ALL THE SAME, THEY WOULD AUTOMATICALLY CONNECT TO EACH OTHER WHICH ALLOWED FOR EASY MEANS OF CIRCULATION. THE RED REPRESENTS NEGATIVE SPACE IN BETWEEN EACH MODULE.

AS YOU CAN SEE, THERE IS A LOT LESS NEGATIVE SPACE WITH THE CONNECTED MODULES AND ALSO ALLOWS FOR 11 PATIENT ROOMS PER TENTACLE AS OPPOSED TO 7-8 IN THE SAME SIZED FOOTPRINT.

THE MORE CURVATURE, THE MORE AREA USED OF THE FOOTPRINT.

INSTEAD OF A CIRCLE, THE HEXAGON WAS INSPIRED BY OUR PROJECT 2 FOR SPRING 2020.


SCHOOL OF ARCHITECTURE & DESIGN

St Joe's Triage Tents 77 N Airlite Street Elgin, IL 60124

St Joseph’s Hospital Physical Therapy (Closest) Entrance

ita

lD

riv

e

St Joseph’s Hospital Main (Realistic) Entrance

’s M

em

ori a

lH

osp

ARCH 509

St

Jo se

ph

EXISTING SITE PLAN

May 13, 2020

DATE

N

EXISTING SITE PLAN 1/32” = 1’-0”

A101


St Joe's Triage Tents 77 N Airlite Street Elgin, IL 60124

SCHOOL OF ARCHITECTURE & DESIGN

ARCH 509

PROPOSED SITE PLAN

May 13, 2020

DATE

N

PROPOSED SITE PLAN 1/32” = 1’-0”`

A102


KEY NOTES:

D

SCHOOL OF ARCHITECTURE & DESIGN

4

6

A108

A108

D

A R C H

5 0 9

4 - SEVERELY ILL, UNLIKELY D TO SURVIVE

+0’ 0” 1 A106

St Joe's Triage Tents 77 N Airlite Street Elgin, IL 60124

D

- 0" TYP

A108

EXTRA D IN CASE OF OVERFILL

St Joe's Triage Tents 77 N Airlite Street Elgin, IL 60124

5 - MORGUE

4

26'

•INNER 2 HEXAGONS REFERRED TO AS “COMMAND CENTER”. •EXTRUDED BAYS FROM COMMAND CENTER REFERRED TO AS “TENTACLES”. •EACH TENTACLE HOLDS DIFFERENT STATUS OF PATIENTS (LABELED 1-5).

1 - LITTLE OR NO TREATMENT – MODERATE/ D MILD SYMPTOMS

MODULE FLOOR PLAN

May 13, 2020

DATE

A103

2 - SIGNIFICANT D INTERVENTION THAT CAN BE DELAYED

ARCH 509

3 - IMMEDIATE LIFESAVING INTERVENTIONS – RESPIRATORS/ D VENTILATORS

MODULE FLOOR PLAN

May 13, 2020

DATE

N

MODULE FLOOR PLAN Level 1 1/8” =1/8" 1’-0”= 1'-0"

A103


1A

SCHOOL OF ARCHITECTURE & DESIGN

Level 4 13' - 0" Level 3 12' - 0" Level 2 10' - 0"

6A

2A

60 .00 °

60.00°

60.00°

° .00 60

MODULE SOUTH ELEVATION 1/4” = 1’-0”

St Joe's Triage Tents 77 N Airlite Street Elgin, IL 60124

Level 1 0' - 0"

60 .00 °

° .00 60

4 A109 2 A107

Sim

3 A107

Sim

Level 4 13' - 0" Level 3 12' - 0" Level 2 10' - 0"

1 A107

5A

PATIENT ROOM

CHANGING STATION

COMMAND CENTER

CHANGING STATION

STORAGE

PATIENT ROOM

3A

PATIENT ROOM

ARCH 509

Level 1 0' - 0"

STRUCTURAL SECTION & PLAN ELEVATION

May 13, 2020

DATE

MODULE SOUTH FACING SECTION 1/4” = 1’ 0”

4A

A104 A106


25' - 10"

0' - 10" 2' - 7"

4' - 6"

4' - 8"

5' - 11"

5' - 2"

5' - 2"

5' - 5"

5' - 3"

17' - 1"

3' - 7"

19' - 5"

1' - 3"

SCHOOL OF ARCHITECTURE & DESIGN

6A

2A

5' - 7"

18' - 0"

0' - 3"

0' - 8"

1' - 11"

2' - 5"

1' - 11"

3J

3' - 1"

1' - 1"

4' - 3"

1A

3A

10' - 1"

10' - 10"

0' - 6"

10' - 1"

60.00°

3G

3F

St Joe's Triage Tents 77 N Airlite Street Elgin, IL 60124

10' - 2"

60 .00 °

° .00 60

10' - 8"

60.00°

6' - 5"

1' - 8"

3H

3B

3C

2' - 7"

4' - 3"

4' - 3"

5' - 3"

8' - 5"

3I

3D

9' - 2"

8' - 0"

6' - 10"

3E

6' 2"

60 .00 °

° .00 60

6'

3J

6" 6' 6" 6'

ARCH 509

2"

5A

3A

3A

STRUCTURAL FOUNDATION PLAN

3I 3B

May May 13, 13, 2020 2020

DATE DATE

3C 3H

N

STRUCTURAL PLAN 1/8” = 1’-0”

4A 3G

3F

3D 3E

A104 A105


25' - 10"

KEY NOTES:

0' - 10" 2' - 7"

4' - 8"

5' - 11"

5' - 2"

5' - 2"

5' - 5"

5' - 3"

17' - 1"

3' - 7"

19' - 5"

2' - 5" 1' - 3"

0' - 3"

0' - 8"

18' - 0"

1' - 11"

1' - 11"

3J

3' - 1"

1' - 1"

4' - 3"

•REINFORCED CONCRETE FOOTINGS 2’X2’. • REINFORCED CONCRETE TIE BEAMS 4”X4”.

4' - 6"

Level 4 13' - 0"

SCHOOL OF OF SCHOOL ARCHITECTURE ARCHITECTURE DESIGN && DESIGN

Level 3 12' - 0"

5' - 7"

Level 2 10' - 0"

6' - 5"

10' - 2"

10' - 1"

10' - 10"

3G

N

0' - 6"

1' - 8"

3H

3B

3C

10' - 1"

3F

10' - 8"

3D

9' - 2"

8' - 0"

6' - 10"

3E

6'

TENTACLE FOUNDATION PLAN 1/4” = 1’-0”

Level 1 0' - 0"

2' - 7"

4' - 3"

4' - 3"

5' - 3"

8' - 5"

3I

2"

KEY NOTES: 3J

6' 6"

•HORIZONTAL PRECAST STEEL SUPPORT 8”X4” •VERTICAL PRECAST STEEL SUPPORT 6”X4”

St StJoe's Joe'sTriage TriageTents Tents 77 77NNAirlite AirliteStreet Street Elgin, Elgin,IL IL60124 60124

3A

4 A109 Sim

3 A107

Sim

Level 4 13' - 0" Level 3 12' - 0"

6'

2 A107

6"

AR RC CH H 55 00 99 A

6'

Level 2 10' - 0"

2"

1 A107

Level 1 0' - 0"

3A

FOUNDATION SECTION & PLAN ELEVATION

3I 3B

May 13, 2020 May 13, 2020

DATE DATE

3C 3H

N

TENTACLE STRUCTURAL PLAN 1/4” = 1’-0”

3D 3G

3F

3E

A105 A106


KEY NOTES: •EACH TENTACLE CAN ATTACH TO OTHER MODULES TO CREATE A MULTIMODULE TRIAGE FACILITY. •ALL TENTACLE INFORMATION IS THE SAME, JUST ROTATED EVERY 60 DEGREES. •TENTACLE CAN EASILY BE CHANGED INTO A WAITING ROOM/ NON EMERGENCY PATIENT ENTRANCE BY REMOVING CURTAINS.

CUSTOM SUPPORT GLAZING

CUSTOM MULLION SYSTEM

ENTRANCE TO COMMAND CENTER

VINYL COATED POLYESTER

VINYL COATED POLYESTER

REMOVABLE DOORS ALLOWING EASY ACCESS FOR AMBULANCE

SCHOOL OF ARCHITECTURE & DESIGN

EMERGENCY ENTRANCE FOR AMBULANCE

PREFABRICATED CUSTOM STEEL FRAMING

VINYL COATED POLYESTER

TYP BED SIZE 6.5’ DEEP X 3.5’ WIDE

CUSTOM STEEL HORIZONTAL MULLION SYSTEM CUSTOM SUPPORT GLAZING

STORAGE AREA FOR PPE AND SUPPLIES

3' CANE BOLT

PREFABRICATED CUSTOM STEEL FRAMING

CUSTOM STEEL VERTICAL MULLION SYSTEM

VINYL COATED POLYESTER

St Joe's Triage Tents 77 N Airlite Street Elgin, IL 60124

MEDICINE CLOSET WITH LOCKABLE DOOR

RETENTION EARS

TYP ROOM SIZE MIN. 9’ DEEP X MIN. 8’ WIDE

4" CONCRETE SLAB

HOSPITAL PRIVACY CURTAINS

COMPUTER DOCKING STATION FOR WORKERS

BACKER ROD & SEALANT

FIBER EXPANSION JOINT

UNDERSLAB VAPOR BARRIER

TENTACLE ENLARGED PLAN 1/4” = 1’-0”

ATTACHMENT FOR SUPPORT BAR

SUPPORT BAR

2" RIGID INSULATION ATTACHMENT FOR SUPPORT BAR

GRAVEL

WEB MEMBRANE

ROLLING AIRLOCK DOOR HOOD

1" GROUT - SOLID

OPERABLE CHAIN BLOCK

CAST STONE

ARCH 509

BEARING ROLLER

GRAVEL DRAIN CONTINUED

WATERSTOP CONTINUED

GEAR PLATE

DETAILS

ROLLING AIRLOCK DOOR CASING

ROLLING AIRLOCK DOOR DISPENSER AND SENSOR

RETENTION EARS

Door 7' - 0"

AUTOMATIC ROLLING AIRLOCK DOOR

SECTION 6 - BAYS AND HALLWAY 1/2” = 1’-0”

SECTION 4 - STORAGE AND MEDICINE BAY 1/2” = 1’-0”

May 13, 2020

DATE

A107


SHELF FOR SUPPLIES SHELF FOR SUPPLIES AUTOMATIC ROLLING AUTOMATIC ROLLING AIRLOCK DOOR AIRLOCK DOOR

SCHOOL OF ARCHITECTURE & DESIGN

BULLETIN BOARD/ BULLETIN BOARD/PROJECTOR PROJECTOR SCREEN SCREEN

DIRTY LAUNDRY BIN FOR DIRTY LAUNDRY BIN FORPPE USED PPE USED

HANDING WASHING HAND WASHING SINK SINK

HOSPITAL PRIVACY HOSPITAL PRIVACY CURTAINS CURTAINS

St Joe's Triage Tents 77 N Airlite Street Elgin, IL 60124

CONFERENCE TABLE TABLE CONFERENCE

WOODEN PANELINGTIMBER FACADE STRUCTURAL WALL 5"

COMPUTER WORK DESK COMPUTER WORK DESK AND RESEARCH AND RESEARCH AREA

9' - 5"

DOUBLE DOORSDOORS STEELSTEEL DOUBLE

8' - 1" 15' - 5" 26' - 0"

COMMAND CENTER ENLARGED PLAN 1/4” = 1’-0”

ARCH 509

Level 4 13' - 0"

Level 2 10' - 0"

Door 7' - 0"

COMMAND CENTER DETAILS

May 13, 2020

DATE

Level 1 0' - 0"

SECTION DETAIL 4 - COMMAND CENTER 1/2” = 1’-0”

A109


SHELF FOR SUPPLIES CUSTOM SUPPORT GLAZING

AUTOMATIC ROLLING AIRLOCK DOOR

CUSTOM MULLION SYSTEM

DIRTY LAUNDRY BIN FOR USED PPE

SCHOOL OF OF SCHOOL ARCHITECTURE ARCHITECTURE & DESIGN DESIGN &

BULLETIN BOARD/ PROJECTOR SCREEN

VINYL COATED POLYESTER

VINYL COATED POLYESTER

HOSPITAL PRIVACY CURTAINS

CONFERENCE TABLE

PREFABRICATED CUSTOM STEEL FRAMING

VINYL COATED POLYESTER

CUSTOM STEEL HORIZONTAL MULLION SYSTEM CUSTOM SUPPORT GLAZING

3' CANE BOLT

PREFABRICATED CUSTOM STEEL FRAMING CUSTOM STEEL VERTICAL MULLION SYSTEM

VINYL COATED POLYESTER

RETENTION EARS

4" CONCRETE SLAB

COMPUTER WORK DESK AND RESEARCH

STRUCTURAL TIMBER WALL 5"

STEEL DOUBLE DOORS

9' - 5"

BACKER ROD & SEALANT

St Joe's Triage Tents 77 N Airlite Street Elgin, IL 60124

HANDING WASHING SINK

FIBER EXPANSION JOINT

UNDERSLAB VAPOR BARRIER

ATTACHMENT FOR SUPPORT BAR 8' - 1"

SUPPORT BAR

15' - 5" 26' - 0"

2" RIGID INSULATION

GRAVEL

ATTACHMENT FOR SUPPORT BAR

WEB MEMBRANE

ROLLING AIRLOCK DOOR HOOD

1" GROUT - SOLID

OPERABLE CHAIN BLOCK

CAST STONE

GRAVEL DRAIN CONTINUED

WATERSTOP CONTINUED

Level 4 13' - 0"

Level 2 10' - 0"

BEARING ROLLER GEAR PLATE

Door 7' - 0"

ROLLING AIRLOCK DOOR CASING

ROLLING AIRLOCK DOOR DISPENSER AND SENSOR

AUTOMATIC ROLLING AIRLOCK DOOR

DETAIL 1 - FOUNDATION PLAN 3” = 1’-0”

AR RC CH H 55 00 99 A

DETAIL 3 - WALL SECTION 3” = 1’-0”

RETENTION EARS

Door 7' - 0"

COMMAND DETAILS CENTER DETAILS

May13, 13,2020 2020 May

DATE DATE

Level 1 0' - 0"

DETAIL 4 - TENTACLE CONNECTION 3” = 1’-0”

A109 A107


COATED VINYLVINYL COATED POLYESTER POLYESTER ROOFING ROOFING

SCHOOL OF ARCHITECTURE & DESIGN

St Joe's Triage Tents 77 N Airlite Street Elgin, IL 60124

PREFABRICATED STEEL PREFABRICATED STEEL FRAMING FRAMING STRUCTURE STRUCTURE

WALLS AND PARTITIONS WALLS AND PARTITIONS

ARCH 509

CONCRETE MODULE CONCRETE FLOOR PLATE FLOOR PLATE

AXONOMETRIC

May 13, 2020

DATE

MODULE AXONOMETRIC 1/16” = 1’-0”

A110


CENTRAL PARK, NEW YORK

MIAMI BEACH, FLORIDA

CHICAGO, ILLINOIS


FACING COMMAND CENTER FROM TENTACLE

COMMAND CENTER

TENTACLE TOWARDS EXIT


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.