Full set nlhs

Page 1

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

F

7

T

2 A06-13

ADD ALT No. 13

C51 TYP

C50 TYP

14

2' - 0"

WP

° 80

x15.3

A12-11

10' - 0"

33' - 0"

23

A12-11

1079

4' - 0"

8

CLASSROOM

CLASSROOM 1077

6

10' - 0"

4' - 0"

12.8

2H

C66

5 C2

TYP

3 A06-14

10' - 0"

4 A06-14

BASE BID

10' - 0"

12

10' - 0"

5

28' - 0" 4' - 0"

37

4' - 0"

37

10' - 0"

8

MATCHLINE

4' - 0"

2H

C1

UP

2 A07-33

1088

5 A06-12

CORRIDOR

P

1' -

1"

S

1'

-1 -R DC

0"

10

IS5

4'

1069

A12-11

1090A

1090A

2"

1

3 A07-35

2 A07-35

RC-1

13 A08-22

A07-35

1093-B

-2 MB

1091

SMALL GROUP

15

15

NIC COT

QUIET ROOM 1090B

-1 TB

1090

4

3' - 3"

9.3

1093B

1055

8

MEN'S TOILET

1051A

PREP

16

16

16

16

1089

1061

MB-2

34' - 8"

26

16

1055A

1057

JAN

COW (NIC)

1061A

1059

VESTIBULE

1087

SP ED OFFICE 9K MB-2

9K

9K

1

8

1053-B

1053-A

1055A

1057

1059

1061A

1092A

1063

1093-A

1065

1067

1063

ELEC

1065

MB-2

1075

2H

AP SEC'Y

DATA

VESTIBULE

42

SCIENCE STOOL NIC, TYP

33

A12-12

9

1053

SCIENCE

16

1055

30

1

1061

1087

1065A

MB-2

26

A12-11

1092A

STORAGE

WORKROOM/ PLANNING/ STORAGE 1093

NIC COT

20

1092B

QUIET ROOM

39 A08-21

1092B

SPECIAL ED

21

A12-10

1092

1065A

ASSISTANT PRINCIPAL

1067

CORRIDOR

1085A

WAITING

10

1085

1093A

23 A08-22

TOILET

1094-A

1094

DIAPER CHANGIN G TABLE

IS6

TLT

WOMEN'S TOILET

MB-2 4

TYP

1085

GUIDANCE

FE

1051A-B

STORAGE

C1

1094-B

15

CLOSET

LIFE SKILLS CLASS

1090B

A12-10

31

TIRE SWING

32

STORAGE

1' - 0"

1078

DISTRIBUTED MEDIA/ LEARNING STREET

7' - 6"

ADD ALT #13

OH

22 A11-14

5 A09-25

LINE OF LEVEL 2 ABOVE

SEE 1 / A04-21B

STADIUM SEATING

10.8

STORAGE

1076

1074A

C1

1075

CORRIDOR

1088

CLASSROOM

1074A

IS4

1083

CLASSROOM

A12-11

7

1071

4

CORRIDOR

C1

C1

4

A12-11

4' - 0"

28' - 0"

ADD ALT #13

7

1081

1081-B

1084-A

2H

CLASSROOM

9H

DISTRIBUTED MEDIA / LEARNING STREET 1074

1086

A12-11

CLASSROOM 1086

38 7

C65

3 A07-01

12' - 0"

IS10

RECYCLING BIN, TYP

2H

1037

OH

17

3

7

1052-B

1056

17

MACH.ROOM

EL-01

ELEVATOR

1054-A

1054-B

1072

STORAGE 1058A

STAIR ST-05.1

9K

IS7

42 OH

9K

1058-A

DC-R-3 DC-R-3

CORRIDOR

C5

1066

VESTIBULE

1068

CORRIDOR

1' - 0"

52D

CORRIDOR IS10

A12-16

IS8

7 A09-10

15 A11-17

9K

1 A09-24

1070

CORRIDOR

3

3 3

34' - 8"

SCIENCE 1052

A12-12

34

17

A12-10

9

1054B

STORAGE

19

8

1054

2D ART

C3

36

7

1060-B

2B

1062-A

FLOOR PLAN GENERAL NOTES

2

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

LSI #6290; EXCEPT 48" HIGH

LSI #6290; EXCEPT 60" HIGH

3X3 SQUARE GALVANIZED STEEL BOLLARD, TYPICAL AT ALL EXTERIOR OUTSWINGING DOORS SHOWN AS THUS . RE: DETAIL 5 ON SHEET A11-17

WALL PROTECTION PADS RE: INTERIOR ELEVATIONS

12" DIAMETER CONC COLUMN RE: STRUCT.

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP, SIM TO EXCEPT 30" WIDE & 60" LONG

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP

KEWAUNEE LAB TABLE ITEM #X90W364800-00_0B9 WITH EPOXY TOP

MOBILE BOOKSHELVES; SEE 42/A12-17

METAL SHIPS LADDER - RE; SPECIFICATIONS

KEWAUNEE LAB TABLE ITEM #T13W362472 WITH EPOXY TOP, SIM TO EXCEPT 90" LONG

LSI #5222 18 WIDE, 84" HIGH

WRAP COLUMNS UP TO BOTTOM CHORD OF ROOF JOISTS

KEWAUNEE #T14W364272 WORK TABLE WITH CASTERS & EPOXY TOP, SIM TO EXCEPT 48" DEEP

6" STEEL PIPE BOLLARD, RE: CIVIL SHEET C03-04 FOR DETAILS

EMERGENCY EYE WASH & SHOWER; RE: PLBG

PAIRED-PANEL OPERABLE PARTITION AT 27'-3" WIDE X 8'-0" HIGH

PAIRED-PANEL OPERABLE PARTITION AT 27'-9" WIDE X 8'-0" HIGH

CAST GFRC COLUMN WRAP

3-TIER METAL STUDENT LOCKER, TYPE ML-1

POWER DOOR OPERATOR ACTUATOR

CEILING MOUNTED TRACK AND CURTAIN

8' HIGH FIRE TREATED PLYWD BACKER BOARD - FULL WIDTH OF WALL

1

23

LSI #6290; EXCEPT 36" HIGH

FLOOR PLAN KEYNOTES

24

LSI #6290; EXCEPT 84" HIGH

1. ALL PLAN DIMENSIONS TAKEN FROM FACE OF GYP BD, MASONRY OPENING OR GRIDLINE UNLESS NOTED OTHERWISE

25

TEACHER DEMONSTRATION TABLE, RE: 40/A12-12

SEE A00-12 FOR MOUNTING HEIGHTS AND WALL MOUNTED DISPLAY BOARDS

5.2

7. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA: • CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE (SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THAN STUD WIDTH ON THE LINE. • ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED. MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".

6. ALL INTERIOR CMU PARTITIONS SHALL EXTEND TO UNDERSIDE OF FLOOR/ROOF DECK ABOVE AND BE BRACED AS PER STURTURAL DRAWINGS, UNLESS NOTED OTHERWISE

5. FOR ALL DOORS NOT SPECIFICALLY DIMENSIONED IN PLAN PROVIDE 4" FROM ADJACENT PERPENDICULAR WALL TO HM/ALUM DOOR/WINDOW FRAME, UNLESS NOTED OTHERWISE

4.

3. TYPICAL PARTITION TYPE TO BE 9H, UNLESS NOTED OTHERWISE. ALL COLUMN WRAP FURRING TO BE WALL TYPE 2H, UNLESS NOTED OTHERWISE.

2. REFER TO CODE COMPLIANCE PLANS (A00-13 AND A00-14) FOR ALL RATED WALL LOCATIONS AND RATING REQUIREMENTS

8. FOR GYP BD ON MTL STUD COLUMN WRAPS NOT SPECIFICALLY DIMENSIONED IN PLAN, STUD FRAMING SHALL BE AS TIGHT TO THE COLUMN AS ALLOWED BY SPRAY-APPLIED FIREPROOFING, MEP ROUGH-IN, STRUCTURAL CONNECTIONS, ETC

26

15' ALUMINUM TILT AND ROLL BLEACHER

MATCHLINE

SEE 1 / A04-21B

8' - 1"

WP

x4.1

27 17

WORK TABLES WITH LOCKERS

1060-C

51C

1062-D

1062C

COMPRESSOR ROOM

1062D

BOTTLE STORAGE

1

9 TYP

2' - 1"

21 TYP

1

19

A07-35

2' - 1"

19

LINE OF ROOF CANOPY ABOVE

2

A07-32

A07-32

Y

X

W

V

U

16' WIDE x 8' TALL MARKERBOARD SURFACE APPLIED TO WALL

1060

TRENCH DRAIN RE: PLBG PLANS

1062-C

1062D

1060-D

USED OIL/ ANTIFREEZE STORAGE

GRINDER & TABLE

28

2 A06-14

SOLVENT TANK

M

PUNCH

SAW

FULL HT

PRODUCTION LAB

WORK TABLES WITH LOCKERS

TO 6' AFF, TYP UON

WS

MATERIAL STORAGE SHELVING (NIC)

40C

50' - 5 5/8"

M

M

OX

HYDRAULIC PRESS

WALL MOUNTED SOUND-ABSORPTIVE PANELS FROM +12" TO +120" AFF

5 A06-14

TOOLS

BRAKE LATHE

PRESSURE WASHER

WORK TABLES WITH LOCKERS

1062

SAW

10' - 0"

5

A07-35

5

29

R

CW-1

FE

WHEEL BALANCER

TIRE MACHINE

WS

M

M

WS

EXHAUST ON FLEX SYSTEM, TYP

TOOLS

WS

M

M

WS

AP

M

M

AP

AP

WS

WS

WS

PRODUCTION LAB

AP

OX

AP

WS

M

8

8

WORK TABLES WITH LOCKERS

52E

WS

TRENCH DRAIN RE: PLBG PLANS TYP OF (2)

FLAMMABLE LIQUIDS CABINET

Q

LINE OF LEVEL 2 BUMPOUT ABOVE

1060-A

CD-1

1060B

TOOL STORAGE 1060B

MB-1 52C UNO

52C

3' - 4"

IS12

OFFICE 1060A

4' - 8"

FULL HT

8' - 8"

IS12

OFFICE 1062A

52C

OX 1062B

TOOL STORAGE 1062B

52C

WS

OX

GRINDER

PLASMA

1060-E

PROVIDE IN-WALL BLOCKING FOR OWNER PROVIDED CHEMICAL DISPENSING SYSTEM. VERIFY EXTENT AND LOCATION WITH OWNER.

52E

IS13

52E 51C

ML-4 LOCKERS RE: 17/A08-20 (SIM) 52E

IS13

52E

CD-1

CURE LAMP

OX FE

OX

POWDER

NORTH

1 A06-14

30

17

17

1054A

52E

ML-4 LOCKERS RE: 17/A08-20 (SIM)

1' - 10"

OFFICE

29

A12-11

38

DESIGN LAB 1058

52E

DESIGN LAB 1064

27

A12-11

28

CW-1

1062-B

WS

° 80

7

1077-A

C1

1084-B

7 8

37 A12-17 A12-11

37

4' - 0"

4 A07-32

8' - 0"

5' - 4" 6' - 0" 5' - 4" 8' - 8" 5' - 4" 5' - 9"

5' - 4" 8' - 8" 5' - 4" 6' - 0"

MB-1 2H 3

21 TYP

7' - 4 3/8 "

1054A

TB-1 MB-1

4' - 3 5/8 "

9' - 10 5/8 "

2' - 1"

E

xH

1 A06-13

BASE BID 22

1073

CORRIDOR

IS3

6

1084

CLASSROOM

A12-11

37

C67

10' - 0"

10' - 0"

1056

5' - 7" 8' - 8" 4' - 0 1/8" 8' - 8" 17' - 3 7/8"

1054B 8' - 0"

3

26' - 9 1/8 "

1

10' - 10"

16' - 8"

1081-A

5' - 4" 8' - 8" 10' - 0"

C51 TYP 10' 0"

C50 TYP

BASE BID

A07-32

3' - 6"

xJ

xJ.5

ST-06.1-A

1082

37

A12-11

1082

SPECIAL ED CLASSROOM

8

4' - 0"

4' - 0"

4' - 0"

10' - 0"

10' - 0"

4' - 0"

4' - 0"

28' - 0"

10' - 0"

4' - 0"

28' - 0"

4' - 0"

4' - 0"

28' - 0"

5 A07-32

2

x4.1

2' - 11 5/8 "

6' - 8"

1089

x9.1 x7.3

2' - 1" A07-31

5

6' - 0"

1 A07-31

19H

ST-06.1

STAIR

19H

C66

1' - 0"

10' - 0"

10' - 0"

1077-B 10' - 0"

28' - 0"

4' - 0"

10' - 0"

10' - 0"

1 A07-30

1 A06-15

3 A07-01

ADD ALT #13

5.2

MB-3

3' - 6"

6.2

2

10' - 0"

9' - 0"

4 A07-33

ST-06.1-B

UP

10' - 0" 9' - 4" 28' - 0"

4

4' - 0" 28' - 0"

3

x12

TYP UON

x11

2 A06-15

ADD ALT #13

8

UP

9' - 10" 2' - 2" 3' - 4" 13' - 11 5/8"

1058A

TB-1

10' - 0" 4' - 0" 10' - 0"

38' - 0" 9' - 0"

BASE BID

1092

TB-1 1093A

1083

LEVEL 01 FLOOR PLAN, AREA A 3

2' - 4"

1093B

27' - 6" 4' - 0"

29' - 0" 4' - 0" 7' - 5" 1091-A

31' - 0 1/8"

1/8" = 1'-0"

1090

14' - 1 1/2 " 10' - 0" 3' - 10 1/4 "

1' - 6" 1091-B 4

6' - 0" 6' - 0"

xK

xL 1 A09-22 OH

STORAGE ST-06.1A ST-06.1-C

x15.3

11' - 4"

10' - 0" 4' - 0"

x15

ADD ALT #13

2 A07-30

1079 ADD ALT #13

x13

A07-30

1

5

1062C

23' - 4"

23' - 4"

10' - 0"

9' - 8"

1058-B 1064-A

1060A 1062A

8" 8"

9' - 4"

2' - 8" 3 ' - 4"

10' - 0"

4' - 1"

8' - 8" 14' - 0" 2' - 10" MB-3 7' - 10" 7' - 4" 1' - 4" 4' - 0"

12' - 0"

2' - 0" A07-30

x14.1

6

1066-C 1066-A

13' - 10 1 /2" 7' - 4"

D

xM

7

1066-D 1066-B

C

B

A

19' - 8"

F

E

D

C

B

A

Lantz-Boggio Architects, P.C.

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

Ph: 303.773.0436 | Fax: 303.773.8709

IN ASSOCIATION WITH:

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

NEW LARAMIE HIGH SCHOOL

Laramie | Wyoming

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022

Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

ITEM

1

#

G

F

E

D

DESCRIPTION

2012.32 15 JANUARY 2014

A

B

C

31 JAN 2014 Addendum No. 1

DATE

ISSUED FOR CONSTRUCTION

ADD

Seal:

Key Plan:

LBA Project Date

LEVEL 01 FLOOR PLAN - AREA A

A04-21A


NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

A

7

11.6

C4 SIM

x

2' - 6"

x14

7 A11-14

J

IS15

21' - 4 1/4 "

3 A08-40

C6A

9K

6

9.5

9K

9K

TB-1

1 A09-27

5 IS15

UP

C10

20

1039A-B

A12-11

30

1039

DESIGN LAB

A07-34

19

MB-3 MB-1

1039A

OFFICE

CUBBIES 1041C

52E

ML-4 LOCKERS RE: 17/A08-20 (SIM) 20' - 0"

1041B

STORAGE

9K

1039A-A

9K

FULL HT

12 A12-15

C6A

9K

2H

8.5

1039

+ 48"

STORAGE

2H

1039B

2H

1041-E

1043-A

C3

15 A11-14

9K

C6A

CORRIDOR 1003

CORRIDOR 1031

HARDWOOD TRIM CAP W/ TRIM AT + 48"

STAIR ST-02.1 C5

5

C6A

1 A09-24

CORRIDOR 1033

CORRIDOR 1035

2H

C9

7 31 A11-17

1000-D

1000-E

VESTIBULE 1000

9' - 9 3/8" 10' - 5"

10' - 0"

39 A11-14

1000-C

1000-B

1000-A

5 A11-18

21

5

5 A07-20

1010A

TLT 1010A 2H

1018

CORRIDOR 1036

8

TYP OF (4)

A07-30

4' - 0"

28' - 0"

23

A12-11

A12-10

HEALTH/ LIFE-LONG LEARNING 1011

TYP

1010

WORKROOM/ PLANNING/ STORAGE

A12-11

26

4

1038

CONFERENCE/ ITINERANT

9K

x10

1000-F 4' - 8 3/4" 4' - 5"

4' - 5"

1011

2H

1031-C

1010-A

1038

1036

21 A11-14

1016

° 80

WAITING

MB-2

SP ED OFFICE

1018A

1040

ELEC

1016 9K

1042

1040

1

1042A

1

30

1048

COW; TYP (NIC)

VESTIBULE

DATA 1044

JAN 1046

VESTIBULE 1048A

3 A06-10

10' - 0"

x9.2

OH

x8

10' - 0"

3' - 3"

1013

4

28' - 0" 4' - 0"

8

7' - 2"

1013

xBB

xCC

C56 TYP

HH.4

23

MB-2

1025

MATCHLINE

7' - 2"

1015

x7

4' - 0"

SEE 1 / A04-21C

C67

2' - 0"

10' - 0"

IS5 10

A12-11

DISTRIBUTED MEDIA/ LEARNING STREET

15

A12-11

A12-10

15

-1 TB

SMALL GROUP 1012 -1 -R DC

1034

1 A07-35

5 A06-14

CORRIDOR

K.6

3

LINE OF LEVEL 2 ABOVE

A07-35

2

13 A08-22

RC-1

1010-B

LIFE-LONG LEARNING

IS14

C1

1012-B

1010B

3H

1' - 1"

CLOSET

15

4' - 0"

1 A06-10

2' - 0"

C67

41' - 4 5/8 "

IS6

23 A08-22 MB-2

STORAGE 1014

MB-2

1018

2H

9K

GUIDANCE

1042

WOMEN'S TOILET

MEN'S TOILET 1048

13

13

A07-35 5 A07-01

N

2

10' - 0"

A07-33

7

28' - 0" 4' - 0"

37

A12-11

1020

2' - 0"

10' - 0"

A

x6

4' - 0"

3

10' - 0"

37

C1

3

8

3

2H

1017

4 3 A06-13

7

FLOOR PLAN GENERAL NOTES

2

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

LSI #6290; EXCEPT 48" HIGH

LSI #6290; EXCEPT 60" HIGH

3X3 SQUARE GALVANIZED STEEL BOLLARD, TYPICAL AT ALL EXTERIOR OUTSWINGING DOORS SHOWN AS THUS . RE: DETAIL 5 ON SHEET A11-17

WALL PROTECTION PADS RE: INTERIOR ELEVATIONS

12" DIAMETER CONC COLUMN RE: STRUCT.

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP, SIM TO EXCEPT 30" WIDE & 60" LONG

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP

KEWAUNEE LAB TABLE ITEM #X90W364800-00_0B9 WITH EPOXY TOP

MOBILE BOOKSHELVES; SEE 42/A12-17

METAL SHIPS LADDER - RE; SPECIFICATIONS

KEWAUNEE LAB TABLE ITEM #T13W362472 WITH EPOXY TOP, SIM TO EXCEPT 90" LONG

LSI #5222 18 WIDE, 84" HIGH

WRAP COLUMNS UP TO BOTTOM CHORD OF ROOF JOISTS

KEWAUNEE #T14W364272 WORK TABLE WITH CASTERS & EPOXY TOP, SIM TO EXCEPT 48" DEEP

6" STEEL PIPE BOLLARD, RE: CIVIL SHEET C03-04 FOR DETAILS

EMERGENCY EYE WASH & SHOWER; RE: PLBG

PAIRED-PANEL OPERABLE PARTITION AT 27'-3" WIDE X 8'-0" HIGH

PAIRED-PANEL OPERABLE PARTITION AT 27'-9" WIDE X 8'-0" HIGH

CAST GFRC COLUMN WRAP

3-TIER METAL STUDENT LOCKER, TYPE ML-1

POWER DOOR OPERATOR ACTUATOR

CEILING MOUNTED TRACK AND CURTAIN

8' HIGH FIRE TREATED PLYWD BACKER BOARD - FULL WIDTH OF WALL

1

23

LSI #6290; EXCEPT 36" HIGH

FLOOR PLAN KEYNOTES

24

LSI #6290; EXCEPT 84" HIGH

1. ALL PLAN DIMENSIONS TAKEN FROM FACE OF GYP BD, MASONRY OPENING OR GRIDLINE UNLESS NOTED OTHERWISE

25

TEACHER DEMONSTRATION TABLE, RE: 40/A12-12

SEE A00-12 FOR MOUNTING HEIGHTS AND WALL MOUNTED DISPLAY BOARDS

7. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA: • CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE (SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THAN STUD WIDTH ON THE LINE. • ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED. MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".

6. ALL INTERIOR CMU PARTITIONS SHALL EXTEND TO UNDERSIDE OF FLOOR/ROOF DECK ABOVE AND BE BRACED AS PER STURTURAL DRAWINGS, UNLESS NOTED OTHERWISE

5. FOR ALL DOORS NOT SPECIFICALLY DIMENSIONED IN PLAN PROVIDE 4" FROM ADJACENT PERPENDICULAR WALL TO HM/ALUM DOOR/WINDOW FRAME, UNLESS NOTED OTHERWISE

4.

3. TYPICAL PARTITION TYPE TO BE 9H, UNLESS NOTED OTHERWISE. ALL COLUMN WRAP FURRING TO BE WALL TYPE 2H, UNLESS NOTED OTHERWISE.

2. REFER TO CODE COMPLIANCE PLANS (A00-13 AND A00-14) FOR ALL RATED WALL LOCATIONS AND RATING REQUIREMENTS

8. FOR GYP BD ON MTL STUD COLUMN WRAPS NOT SPECIFICALLY DIMENSIONED IN PLAN, STUD FRAMING SHALL BE AS TIGHT TO THE COLUMN AS ALLOWED BY SPRAY-APPLIED FIREPROOFING, MEP ROUGH-IN, STRUCTURAL CONNECTIONS, ETC

26

15' ALUMINUM TILT AND ROLL BLEACHER

BASE BID

2

A07-30

x3

2H

7' - 11 1/2 "

ST-01.1-B

2' - 5 3/8 "

1 A11-18

ST-01.1

STAIR

3' - 4 1/2 "

19H

19K

A07-31

1

x2

27

4 A06-13

1 A07-30

3' - 1 1/4 "

C66

10' - 0"

C50 TYP

ADD ALT #13

28' - 0"

4' - 0"

8

1021

5' - 6 5/8 "

2H

ST-01.1-A

WP

1' - 8 1/8"

3 A11-18

22

7' - 0"

3

A07-33

K

20' - 8"

STORAGE

ST-01.1A

4

A07-33

ADD ALT #13

x1

16' WIDE x 8' TALL MARKERBOARD SURFACE APPLIED TO WALL

4

x4

4' - 0"

10' - 0"

37

A12-11

1021

SPECIAL ED CLASS

23 A11-14

1030

7

A12-11

CORRIDOR

1026

CLASSROOM

IS3

22' - 11"

1026-A

A12-11

CLASSROOM 1024

10' - 0"

9' - 4"

28

x5

6

C51 TYP

8

24

4' - 0"

xG

xC

xD

ADD ALT #13

BASE BID

xE

2 A06-13

1 A06-13

xF

xB

1 A09-22

WALL MOUNTED SOUND-ABSORPTIVE PANELS FROM +12" TO +120" AFF

1026-B

16 A11-14

10' - 0"

ADD ALT #13

TYP

7' - 7"

5

A07-30

4' - 0"

28' - 0"

37

A12-11

2H

1024

10' - 0"

° 80

17' - 4"

29

10' - 0" C67

7

1019

1019-B

C1

2' - 0"

4' - 0"

C2

CLASSROOM

17' - 5"

7' - 6" 6' - 6"

1022-A

C67

C50 TYP

33' - 0"

1

ST-01.1-C

PROVIDE IN-WALL BLOCKING FOR OWNER PROVIDED CHEMICAL DISPENSING SYSTEM. VERIFY EXTENT AND LOCATION WITH OWNER.

4' - 0" 8 1/4"

1029

DISTRIBUTED MEDIA / LEARNING STREET

1022

7

10' - 0"

2

NORTH

xA

30

A12-11

37

4' - 0" 28' - 0"

4 3 A06-14

ADD ALT #13

CLASSROOM

1022-B

6' - 6"

1019-A

8 1/2"

ADD ALT #13

10' - 0"

2' - 0"

5 A09-25

10' - 0"

BASE BID

ADD ALT #13

6' - 6"

A07-30

4' - 0"

4' - 0"

A07-33

1

C1

4' - 0"

28' - 0"

1017

CLASSROOM

A12-11

1028

4

TYP

10' - 0" C51

IS4

1032

CORRIDOR

TYP

CORRIDOR

20' - 6"

1029A

STORAGE 1029A

A12-11

1020

CLASSROOM

8

37

28' - 0"

4' - 0"

LOW BOOKSHELVES, TYPICAL AT CLASSROOMS

10' - 0"

22 A11-14

1027

STADIUM SEATING

4

CLASSROOM 1015

2H

19' - 10"

C1

3/4"

C1

UP

ADD ALT #13

2' - 0"

4

4 A06-14

11' - 4"

xAA C4

9K

9K

42

CW-1

A12-11CD-1

1041A

51C ML-4 LOCKERS RE: 17/A08-20 (SIM)

38

A12-11

29

STORAGE 1047

1049-A

IS8

1042A

1044

1046

1048A

FE 13

7

13

13

FE

FE

29' - 8"

CULINARY ARTS 1041

FE

9K

LAUNDRY 1041A

52E

4' - 8"

TYP CMU

8

2' - 8" 52E

IS13

52E

DESIGN LAB 1045

1045-A DC-R-3 DC-R-3

7 A09-24 FD

1' - 0"

1050-A 13

33

A12-12

8

MB-1

27' - 6"

1041-B

1' - 4"

SB-1 SCROLL SAWS

IS12

1043A

OFFICE

MB-1 52C

1043B

TOOL STORAGE 1043B

CD-2

1043-D

10

A12-14

42

9

SCIENCE 1050

26

19

A12-12

13 A11-14

N.2

14' - 0"

xA

1041-C

2K

51C

MATERIAL STORAGE SHELVING (NIC)

FULL HT

WORK TABLE

WORK TABLE

WORK TABLE FE WORK TABLE CW-1

CLAMP STORAGE

CLAMP TABLE

HAND TOOLS

STAIR ST-03.1

22

A12-10

41

IS10

9K

PREP

FE

MATCHLINE SEE 1 / A04-21A

2' - 1"

F

1041-D 21 9

TRENCH DRAIN

SANDER

72" AFF

WORK TABLE 40C

DP

8"

POTTERS WHEELS (NIC)

3D ART 1049 PUGMILL (NIC)

1049A

STORAGE

1051-A

1050-B 3' - 0"

1050A-A

1050A

35

2' - 4 7/8 " 8

16

16

25' - 11 1 /8"

STAIR

9

1043-C

TABLE SAW

PRODUCTION LAB 1043

WORK TABLE

PANEL ROUTER

ST-03.1 4' - 0"

1049-B

FD

FD

STORAGE 1049C

1049B

KILN

16

IS10

2H

9K

36

7' - 4"

ST-9.1

2 A06-12

2' - 0"

SIM

3 A06-12

2 A07-32

9

COMPRESSED AIR 1043C

WORK TABLE

LATHE

4 A07-35

FD

16

SCIENCE 1051 34

A12-12

42 OH

1051-B

26

SCIENCE 1052 8

A12-12

29' - 8"

B

1 A07-32 SIM

9

1043C 10' - 0"

CHISELS WP

30' - 10 1/4"

W5

12' AFF

18' - 0"

1049C-B

TYP

1039B 36

8

26

9K

1052-A

42 OH

3' - 0"

D

E

F

G

H

J 24' - 1 1/4"

DUST COLLECTOR

KILN W5

8' AFF

21

16

16

16

16

8

1' - 0"

1' - 0 1/2" IS10

1014

E

D

C

x14 5 A07-35

4 A06-12

13' - 0"

L

M

13 A11-14 FE

PREP 1051A FH-1

1

13' - 10 1 /2"

3' - 0"

LEVEL 01 FLOOR PLAN, AREA B 1/8" = 1'-0" 2

14' - 1 1/2 "

PLANER

5 A06-12

N.5

24

A12-12

20

34' - 8"

1012-A

3' - 10 1/4 "

10' - 0"

4' - 0"

10' - 0"

1' - 6"

1010B

1031-B UP

1' - 4"

5.2

1

3

2' - 4"

VDC

6' - 0"

2' - 0"

1041-A JOINTER

11 1/2" 12' - 0"

7

4

10' - 0"

4' - 0"

10' - 0"

4' - 0"

1' - 7 3/4 "

4' - 8"

3' - 0" SAWCUT CONTROL JOINT, TYP RE: SITE AND CIVIL PLANS FOR ART PLAZA

MATCHLINE

1045-B 34' - 8"

8

TB-1

1043A

1041B FE

9.3

5

4' - 0" 27' - 0" 2' - 2" 8' - 8" 5' - 4" 6' - 0" 5' - 4" 8' - 8" 5' - 4" 6' - 0" 5' - 4" 8' - 8" 5' - 4"

2' - 3 1/4" 12' - 11" 2' - 4" 3' - 6" 2' - 3 1/4" 7' - 4 1/2" 21' - 11" 6' - 5 1/2" 2' - 6" 5' - 11" 2' - 10" 4' - 0"

1050A-B 1050A-C

3' - 6" 1037

TB-1

31' - 3 3/4"

CORRIDOR

TB-1

1031-A 2' - 0 7/8" 5' - 10 1/8" 21' - 11" 5' - 6 1/8" 4' - 9"

1047 1049A

2' - 0" 5' - 5 1/4" 36' - 7 1/2" DC-R-3 DC-R-1 DC-R-3 3' - 0" 4' - 0" 3' - 0" 3' - 6" 10' - 2" 6' - 6"

1049B

MB-3

MATCHL INE SEE 1 / A04-21 D

1043-B

2' - 8"

SEE 1 / A04-21A

P

6

MB-1

1049C-A

16' - 0" 9' - 4" 3' - 6"

5' - 8"

1' - 0" 3' - 4" 4" 4' - 2" 3' - 4" 6' - 4" 8' - 8" 4' - 0" 8' - 8" 6' - 8" 3' - 4" 6' - 8" 8' - 8" 5' - 4" 6' - 0" 5' - 4" 8' - 8" 5' - 4" 6' - 0"

6' - 8" 11' - 4" 12' - 0"

3' - 11"

MITER SAW 23' - 4"

1' - 8" 4' - 0"

9' - 0" BANDSA W SANDER S

10' - 0"

7

1051A 1051A-B

B

A

9' - 4"

23' - 4" 23' - 4" 16' - 8" 10' - 10"

F

E

D

C

B

A

Lantz-Boggio Architects, P.C.

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

Ph: 303.773.0436 | Fax: 303.773.8709

IN ASSOCIATION WITH:

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

NEW LARAMIE HIGH SCHOOL

Laramie | Wyoming

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022

Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

ITEM

1

#

G

F

E

D

DESCRIPTION

2012.32 15 JANUARY 2014

A

B

C

31 JAN 2014 Addendum No. 1

DATE

ISSUED FOR CONSTRUCTION

ADD

Seal:

Key Plan:

LBA Project Date

LEVEL 01 FLOOR PLAN - AREA B

A04-21B


5

4 2' - 4"

2' - 8"

6' - 0"

9' - 0"

1' - 4"

9' - 0"

DUMPSTER (BY OWNER)

7' - 4"

1' - 4"

DUMPSTER (BY OWNER)

3

9' - 0"

FLOOR PLAN KEYNOTES

1. ALL PLAN DIMENSIONS TAKEN FROM FACE OF GYP BD, MASONRY OPENING OR GRIDLINE UNLESS NOTED OTHERWISE

DUMPSTER (BY OWNER)

A07-21

1

8' HIGH FIRE TREATED PLYWD BACKER BOARD - FULL WIDTH OF WALL

2

CEILING MOUNTED TRACK AND CURTAIN

3

POWER DOOR OPERATOR ACTUATOR

3. TYPICAL PARTITION TYPE TO BE 9H, UNLESS NOTED OTHERWISE. ALL COLUMN WRAP FURRING TO BE WALL TYPE 2H, UNLESS NOTED OTHERWISE.

4

3-TIER METAL STUDENT LOCKER, TYPE ML-1

4.

5

CAST GFRC COLUMN WRAP

6

PAIRED-PANEL OPERABLE PARTITION AT 27'-9" WIDE X 8'-0" HIGH

7

PAIRED-PANEL OPERABLE PARTITION AT 27'-3" WIDE X 8'-0" HIGH

8

EMERGENCY EYE WASH & SHOWER; RE: PLBG

9

6" STEEL PIPE BOLLARD, RE: CIVIL SHEET C03-04 FOR DETAILS

10

KEWAUNEE #T14W364272 WORK TABLE WITH CASTERS & EPOXY TOP, SIM TO EXCEPT 48" DEEP

11

WRAP COLUMNS UP TO BOTTOM CHORD OF ROOF JOISTS

12

LSI #5222 18 WIDE, 84" HIGH

13

KEWAUNEE LAB TABLE ITEM #T13W362472 WITH EPOXY TOP, SIM TO EXCEPT 90" LONG

NEW LARAMIE HIGH SCHOOL

14

METAL SHIPS LADDER - RE; SPECIFICATIONS

Laramie | Wyoming

15

MOBILE BOOKSHELVES; SEE 42/A12-17

16

KEWAUNEE LAB TABLE ITEM #X90W364800-00_0B9 WITH EPOXY TOP

17

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP

18

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP, SIM TO EXCEPT 30" WIDE & 60" LONG

19

12" DIAMETER CONC COLUMN RE: STRUCT.

20

WALL PROTECTION PADS RE: INTERIOR ELEVATIONS

21

3X3 SQUARE GALVANIZED STEEL BOLLARD, TYPICAL AT ALL EXTERIOR OUTSWINGING DOORS SHOWN AS THUS . RE: DETAIL 5 ON SHEET A11-17

22

LSI #6290; EXCEPT 60" HIGH

23

LSI #6290; EXCEPT 48" HIGH

24

LSI #6290; EXCEPT 36" HIGH

25

LSI #6290; EXCEPT 84" HIGH

26

TEACHER DEMONSTRATION TABLE, RE: 40/A12-12

27

15' ALUMINUM TILT AND ROLL BLEACHER

28

16' WIDE x 8' TALL MARKERBOARD SURFACE APPLIED TO WALL

29

WALL MOUNTED SOUND-ABSORPTIVE PANELS FROM +12" TO +120" AFF

30

PROVIDE IN-WALL BLOCKING FOR OWNER PROVIDED CHEMICAL DISPENSING SYSTEM. VERIFY EXTENT AND LOCATION WITH OWNER.

2. REFER TO CODE COMPLIANCE PLANS (A00-13 AND A00-14) FOR ALL RATED WALL LOCATIONS AND RATING REQUIREMENTS

TRANSFORMER

7

19' - 11"

1

FLOOR PLAN GENERAL NOTES

CONCRETE PAVING 97'-6" (RE: CIVIL)

F

2

9' - 7 5/8"

6

9' - 0"

7

SS

SEE A00-12 FOR MOUNTING HEIGHTS AND WALL MOUNTED DISPLAY BOARDS

5. FOR ALL DOORS NOT SPECIFICALLY DIMENSIONED IN PLAN PROVIDE 4" FROM ADJACENT PERPENDICULAR WALL TO HM/ALUM DOOR/WINDOW FRAME, UNLESS NOTED OTHERWISE

STEP SITE WALL FOOTINGS AND FOUNDATIONS TO FOLLOW CONTOUR OF ADJACENT GRADE

6. ALL INTERIOR CMU PARTITIONS SHALL EXTEND TO UNDERSIDE OF FLOOR/ROOF DECK ABOVE AND BE BRACED AS PER STURTURAL DRAWINGS, UNLESS NOTED OTHERWISE 7. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA: • CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE (SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THAN STUD WIDTH ON THE LINE. • ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED. • MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".

TRANSFORMER

A07-21

9

CHAIN LINK FENCE

7

8 28' - 4"

6.3

12' - 0"

8. FOR GYP BD ON MTL STUD COLUMN WRAPS NOT SPECIFICALLY DIMENSIONED IN PLAN, STUD FRAMING SHALL BE AS TIGHT TO THE COLUMN AS ALLOWED BY SPRAY-APPLIED FIREPROOFING, MEP ROUGH-IN, STRUCTURAL CONNECTIONS, ETC

11' - 0"

2

CHILLER 2

A07-21 W9

8' - 0"

1

6' - 0"

6' - 0"

8' - 0"

2B

ORCHESTRA

42' - 0" 2' - 6"

A12-13

17

1136

37

x9

A07-21

8' - 0"

COOLING TOWER

W9

2 A06-10

1130-B

42' - 3"

6' - 0"

11K A12-13

40

2B

1136A-B 11

INSTRUMENTAL

1134 1134-B

11K

10' - 10"

8' - 2"

1' - 0"

MB-3

EWC

SOUND AND A/V CABINET

SB-1

1122-B

1' - 4"

TYP

SIM

9' - 8"

PRACTICE

KK

1124

1137

ST-09.1

UP

ST-08.1

19H

LIFT-01

ST-07.1B

CORRIDOR

13H

STAIR

1119

13H

VAULT 1110A

1112

3H

A

1111

KITCHENETTE

1115

1117A

6' - 8"

1109 1109

12 A12-14

MB-1 VDC

1107-A

1107

CORRIDOR

1118

1106

1117

1127

1125

2H

10°

RECEPTION

SUB SECRETARY

1102

11

PIT LEVEL FLOOR PLAN 6

5

10' - 0" CMU OPENING

16' - 8"

42 A08-22

E

F

D

C

BB

B

1147

24' - 0"

A

LBA Project Date

41 A12-10

WAITING 1100

AA.1

A

C7

4' - 0"

6' - 8"

A

2012.32 15 JANUARY 2014

LEVEL 01 FLOOR PLAN - AREA C

MATCHLINE NORTH

SEE 1 / A04-21B

16' - 0" 7' - 4"

3 A08-40

1

1/8" = 1'-0"

16' - 8"

G

1101

1100-B 16' - 0" CMU OPENING

4' - 0"

1103

Key Plan:

C56 TYP

4' - 0"

TB-2

2H

1129

1123

1127-A

A

EL-02

1100-A

1155

VEST

REGISTRAR

1104

ELEVATOR

1120

1129-A

VEST

13H

MACH RM

1147

FAMILY TOILET

A12-11

1104

MB-1

10°

1123

12

RECORDS STORAGE

3' - 9 7/8 "

1125

14' - 0"

6' - 8"

WOMEN'S TOILET

1155

2 A09-25

7

MEN'S TOILET

11

13H

9 A09-10

1149

COATS

W14

2

1149

TB-1

11 OH

2B

W14

LIFT-01

JAN

MB-3

1120

9K

TB-1

13H

EL-02.1

4' - 8"

HH

1143

UP

LIFT REFER TO "TH" SERIES DRAWINGS FOR ADDITIONAL INFORMATION

CORRIDOR

HH.3

STAIR

A

30

4' - 8"

1143A

W14

ST-08.0

9K

RECYCLING

24' - 0"

932

1151

7' - 4"

1157

13H

GUN SAFE (NIC)

1151

W14

1118-A

8' - 0"

DATA

932 91'-0"

1153

1157

KK

A07-20

8' - 0"

6.3

3

A12-16

8' - 0"

1143

1105

9K

12' - 0"

ORCHESTRA PIT VESTIBULE

PRINCIPAL

1153

24' - 0"

SECRETARY

8' - 0"

ATTENDANCE

ELEC

CAFETERIA STORAGE

Seal:

1105 1118-B

7

DD

4' - 0"

1107-B

AED

1145

B

10°

B

CORRIDOR

31 JAN 2014 Addendum No. 1

1 A06-10

TB-1

CONF

1108

9K

1

DESCRIPTION

FF

1' - 0"

A

45' - 4"

CORRIDOR

1108

ADD

DATE

4' - 8"

AD/AP OFFICE

1110

60' - 8"

42 A08-21

1111

9H

WRKRM/ MAIL/ STOR

#

MB-1

TOILET

1115

ITEM

HH.4

1113-A

1110

MB-1

REFER TO 'TH' SERIES DRAWINGS

31

13H

BOOKEEPER MB-1

AD/AP SEC'Y

A12-14

CLOSET 1113B

1110A

CORRIDOR

1113B

2

1113

24' - 0"

MB-1

1113A

2

4' - 8"

1116

NURSE

24' - 0"

1114

8' - 0"

SRO

COTS

36 A08-21 1114

15 A11-18

8' - 0"

8' - 0"

8' - 0"

TOILET

C

19H

1113-B

1116

1139

ST-07.1

ST-07.1A

3' - 8"

WCL-01.2

HH

8' - 0"

12' - 3 1/8"

LIFT

HH.3

ST-08.1

STAIR

DN

10°

19K

TB-1

10°

13' - 8"

1131A

STAIR

11K

11K

x9.3

10' - 0"

PIANO STOR

13 A11-18

1 A09-25

24' - 0"

21' - 4"

1122-A

4' - 0"

ST-09.1A

5' - 0 7/8"

ST-09.1B

1124-B

1' - 4"

8' - 0"

6' - 8" 1131A

8' - 4"

ISSUED FOR CONSTRUCTION

1122

1124-A

7

2 A07-21

CHORAL

13' - 0 3/8"

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

29' - 0"

A12-15

8' - 0"

PRACTICE 11K

D

25

1126-B 13' - 5 3/4"

15' - 7" 1131

MM

4' - 0"

16

1126-A

32' - 0"

STAGE

3' - 4"

8

8' - 0"

6' - 8"

MB-3

11K

11K

1137

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

MM.9

25

3' - 2"

7' - 4"

1131-A

A12-13

1130A

CORRIDOR

32' - 0"

SEE 1 / A04-21D

11K

40

11K

1126

MATCHLINE

27

INSTRUMENT STORAGE

11' - 3"

A12-16

C

26' - 0" 1130A-A 1128

7' - 4"

4' - 8"

STORAGE

A12-11

1' - 0" 1133-B

1131-B 5' - 4"

41

1128

3' - 6"

CORRIDOR 1133

8' - 5"

7' - 6" 9' - 7"

IS8

12' - 0"

MB-2

MB-2

1130A-B

MB-2

4' - 7 1/2"

1131-C

SEE 1 / A04-21E

MATCHLINE

5' - 8" 3' - 10"

D 1133-A

3' - 8 1/2"

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

11K

4' - 2"

1140

5 A11-14

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

9 A11-14 11K

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

2B

SOUND AND A/V CABINET

SB-1

1' - 4" 11K

1140

1142-A

1144

1150-B

9K

1' - 4"

1135

1' - 0"

MB-1 1139

CORRIDOR

1142

9K

8' - 0"

3' - 6"

42

TB-1

1130-A

CORRIDOR

OFFICE/ MUSIC LIBRARY

E

11K

IS22

14

TB-1

COSTUME/ PROP STORAGE

1144

UP

1132

8' - 0"

1142-B

MAKEUP

5' - 1"

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

14

PRACTICE

1' - 8" 7' - 0"

1146

1138

3' - 8"

1148

1132-A

1138

1146

1150-C

DRESSING

1148

4' - 8"

DRESSING

1139

11' - 4"

1150A

1150-A

A12-13

16

1132-B

FLAT STORAGE FD

13

1134-A

9K

INSTRUMENT STORAGE

31' - 4"

4' - 4"

11K

18

29

1150

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

PP

4' - 0"

A12-13

3' - 6"

30

ENSEMBLE

5' - 10"

1146A

TB-1

TOILET

1148A

11K

1136

TOILET

1146A

1148A

12' - 8"

37 A08-21

3' - 10"

11K

STAGE CRAFT

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

1130

8' - 0"

MB-2

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

4' - 0"

11K MB-2 28

9K

IN ASSOCIATION WITH:

8' - 0"

SWITCHBOARD METERING COMPARTMENT AND DISCONNECT

1' - 11"

W2

SWITCHBOARD METERING COMPARTMENT AND DISCONNECT

SOUND AND A/V CABINET SB-1

3' - 2"

A07-21

7' - 0"

3

GENERATOR

1176-A

Ph: 303.773.0436 | Fax: 303.773.8709

4 A07-21

1150-D

xEE

1136A-A

1136A

26

10

1139-B

INSTRUMENT STORAGE

1' - 6"

11

12

11K

38

2' - 6"

EXTERIOR EGRESS PASSAGE

° 85

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

8' - 0"

E

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

CHILLER 1 6

11.6

Lantz-Boggio Architects, P.C.

1

3' - 4"

A07-20 37 A08-22

8

7

6

3 A06-10

A04-21C

x9.2

LEVEL 01 FLOOR PLAN, AREA C 1/8" = 1'-0" 4

3

2

1


7

6

5

4

3

2

1

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEYNOTES

1. ALL PLAN DIMENSIONS TAKEN FROM FACE OF GYP BD, MASONRY OPENING OR GRIDLINE UNLESS NOTED OTHERWISE

1

8' HIGH FIRE TREATED PLYWD BACKER BOARD - FULL WIDTH OF WALL

2

CEILING MOUNTED TRACK AND CURTAIN

3

POWER DOOR OPERATOR ACTUATOR

3. TYPICAL PARTITION TYPE TO BE 9H, UNLESS NOTED OTHERWISE. ALL COLUMN WRAP FURRING TO BE WALL TYPE 2H, UNLESS NOTED OTHERWISE.

4

3-TIER METAL STUDENT LOCKER, TYPE ML-1

Ph: 303.773.0436 | Fax: 303.773.8709

4.

5

CAST GFRC COLUMN WRAP

6

PAIRED-PANEL OPERABLE PARTITION AT 27'-9" WIDE X 8'-0" HIGH

IN ASSOCIATION WITH:

7

PAIRED-PANEL OPERABLE PARTITION AT 27'-3" WIDE X 8'-0" HIGH

8

EMERGENCY EYE WASH & SHOWER; RE: PLBG

9

6" STEEL PIPE BOLLARD, RE: CIVIL SHEET C03-04 FOR DETAILS

10

KEWAUNEE #T14W364272 WORK TABLE WITH CASTERS & EPOXY TOP, SIM TO EXCEPT 48" DEEP

11

WRAP COLUMNS UP TO BOTTOM CHORD OF ROOF JOISTS

12

LSI #5222 18 WIDE, 84" HIGH

13

KEWAUNEE LAB TABLE ITEM #T13W362472 WITH EPOXY TOP, SIM TO EXCEPT 90" LONG

14

METAL SHIPS LADDER - RE; SPECIFICATIONS

15

MOBILE BOOKSHELVES; SEE 42/A12-17

16

KEWAUNEE LAB TABLE ITEM #X90W364800-00_0B9 WITH EPOXY TOP

17

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP

18

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP, SIM TO EXCEPT 30" WIDE & 60" LONG

19

12" DIAMETER CONC COLUMN RE: STRUCT.

20

WALL PROTECTION PADS RE: INTERIOR ELEVATIONS

21

3X3 SQUARE GALVANIZED STEEL BOLLARD, TYPICAL AT ALL EXTERIOR OUTSWINGING DOORS SHOWN AS THUS . RE: DETAIL 5 ON SHEET A11-17

22

LSI #6290; EXCEPT 60" HIGH

23

LSI #6290; EXCEPT 48" HIGH

24

LSI #6290; EXCEPT 36" HIGH

25

LSI #6290; EXCEPT 84" HIGH

26

TEACHER DEMONSTRATION TABLE, RE: 40/A12-12

27

15' ALUMINUM TILT AND ROLL BLEACHER

28

16' WIDE x 8' TALL MARKERBOARD SURFACE APPLIED TO WALL

29

WALL MOUNTED SOUND-ABSORPTIVE PANELS FROM +12" TO +120" AFF

30

PROVIDE IN-WALL BLOCKING FOR OWNER PROVIDED CHEMICAL DISPENSING SYSTEM. VERIFY EXTENT AND LOCATION WITH OWNER.

2. REFER TO CODE COMPLIANCE PLANS (A00-13 AND A00-14) FOR ALL RATED WALL LOCATIONS AND RATING REQUIREMENTS

SEE A00-12 FOR MOUNTING HEIGHTS AND WALL MOUNTED DISPLAY BOARDS

5. FOR ALL DOORS NOT SPECIFICALLY DIMENSIONED IN PLAN PROVIDE 4" FROM ADJACENT PERPENDICULAR WALL TO HM/ALUM DOOR/WINDOW FRAME, UNLESS NOTED OTHERWISE 6. ALL INTERIOR CMU PARTITIONS SHALL EXTEND TO UNDERSIDE OF FLOOR/ROOF DECK ABOVE AND BE BRACED AS PER STURTURAL DRAWINGS, UNLESS NOTED OTHERWISE

F

7. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA: • CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE (SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THAN STUD WIDTH ON THE LINE. • ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED. • MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR". 8. FOR GYP BD ON MTL STUD COLUMN WRAPS NOT SPECIFICALLY DIMENSIONED IN PLAN, STUD FRAMING SHALL BE AS TIGHT TO THE COLUMN AS ALLOWED BY SPRAY-APPLIED FIREPROOFING, MEP ROUGH-IN, STRUCTURAL CONNECTIONS, ETC

2

13.1 12.9

A07-02

11.6

52C

52C

MB-1

52C

MAIN ELEC

MECH 1170

12' - 0"

SIM

8' - 8"

1' - 4" 3' - 4"

52B

1170-B

52C

6' - 8"

8" RECESSED CONC SOG, RE: FS DRAWINGS FOR DIMENSIONS

DATA

JAN

1164

1164A

MB-2

12' - 7 1/4"

COMPETITION GYM 1167

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

E

GG.3

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187 Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

1164A

OFFICE 1162A

TOILET 1162B

1162A

1' - 7 3/4"

1 A08-22

1162B

TB-1

D

9' - 0" 9H 2' - 0"

4' - 11"

REFER TO FS DRAWINGS FOR FOOD SERVICE EQUIPMENT AND LAYOUT

1180

DRY STORAGE

1162C

52C

1162C 13' - 0"

H

KITCHEN 10' - 6"

52C 8' - 4"

1162-C

TRAY DROP

2' - 0"

J

2' - 4"

BB.5

FE

10' - 3"

1162-A

A/V EQ 1163A

2' - 10"

18' - 2"

14' - 0"

52D

17' - 4"

CONCESSION

SERVERY

1161

1160

2' - 8"

14' - 0"

CJ 12' - 0" 1161-B

6' - 8"

2' - 4"

2' - 4"

12' - 4 3/8"

DESCRIPTION

MATCHLINE SEE 1 / A04-21B

1002B

40 A08-20

5

2

TYP C7

C7

C7

C7

C7

3 15' - 0"

A07-12

15' - 0"

B

4' - 11 3/8"

A08-40

C7

DATE

A 2' - 8"

CORRIDOR

B

#

FE

1161-A 5' - 4"

ITEM 8' - 11 3/4"

3H

52D 1167-A

1167-B

52D

1163

5' - 4"

52D

52D

2' - 4"

3H

2' - 8"

CJ

2' - 8"

52D

EQUIPMENT STORAGE

3' - 6"

1167-C

1165

C

8D

1' - 0" 1' - 7 5/8"

52D

52D

8"

7' - 4 3/8"

3' - 0"

4

6' - 8" 1167-D

UNIFORM STORAGE 8' - 0"

6' - 8"

A12-14

4' - 8"

1163A

52D

1165

18x42 wall mntd rack

54D

CJ

1163

20

CJ

A

17' - 0 1/4"

14' - 8"

C

1143

CORRIDOR

1180

1160-B

10' - 3"

1160-A

51C

3' - 4"

REFER TO SHEET A08-12 FOR CROSS COURT STRIPING PLANS

ISSUED FOR CONSTRUCTION

1143

3' - 4"

REFER TO SHEET A08-10 FOR COMPETITION COURT STRIPING PLANS

6' - 3"

52C

1162

12' - 8"

54D

1139

6' - 8"

52C 48"

42

17

CORRIDOR

EE

CORRIDOR

A08-14

1162-B FE

52C 51C

18

52C

7' - 8"

41

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

ML-2 LOCKER

2' - 8"

2' - 4"

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

1164

FD

9H

D

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

1166

1166

1' - 11 1/4"

54D

1168-B

SUPPLY STORAGE

52C

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

2-TIER LOCKERS

12' - 0"

Laramie | Wyoming

52C

FLAMMABLE STORAGE

1172

33 A10-01

1168

22' - 0"

A07-11

MAINTENANCE SHOP

18' - 0"

7

JJ.7

NEW LARAMIE HIGH SCHOOL

5' - 4"

FE

8' - 8"

FE

3' - 4"

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

6' - 8"

33 A10-01

CMU TO 9'-4" AFF WALL TYPE 8H ABOVE TO ROOF DECK

13' - 4 3/8"

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

12' - 8"

1167-H

4' - 0"

1168-A

10' - 7 5/8"

54D

E

MATCHLINE

CORRIDOR

SEE 1 / A04-21E

WORKBENCH

6' - 8" 4' - 4"

4"

MATCHLINE 1174

52C CMU TO 9'-4" AFF WALL TYPE 8H ABOVE TO ROOF DECK

54D 52C

1169-F

1170-A

1167-E

20

16' - 0"

4' - 4"

1167-G

4" SEE 1 / A04-21F

MATCHLINE

6' - 8"

1172

6' - 8"

1167-F

16' - 0"

SEE 1 / A04-21C

1169-A

C

1 A12-12

1 A08-30

19' - 3 1/4"

TYP OF (3)

B

B

Seal: 18' - 0"

41' - 8"

13' - 4"

xAA COMMONS 1002

Key Plan: DC-F-1, TYP OF (4) 17 A11-18

C8

C.8

UP

C8

3' - 8"

37' - 4"

12' - 4"

2' - 0"

C68 TYP

15' - 4"

30' - 8"

7

6

15' - 4"

2' - 0"

15' - 4"

1' - 11 5/8"

3' - 0"

35' - 7 5/8"

15

14.2 2 A06-12

1

2' - 0"

C53 TYP

C8

1002-A

4' - 2" 4' - 0"

15.9

D A

LBA Project Date

11 A11-18 8 A09-24

A 38' - 8 3/8"

13

11.6

2012.32 15 JANUARY 2014

LEVEL 01 FLOOR PLAN - AREA D

NORTH

A04-21D

LEVEL 01 FLOOR PLAN, AREA D 1/8" = 1'-0" 5

D

B 9"

3' - 8" C8

A

F

ST-9.1

ST-9.1

15' - 4"

7' - 2"

2' - 0"

3' - 5 5/8"

15' - 4"

6' - 0"

2' - 0"

E

1041-C

STAIR

19H

12 A11-18

1002-B

D.5

SEE 1 / A04-21F

MATCHLINE

15' - 4"

C53 TYP

G

C C8 C8

12' - 0"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

16

Lantz-Boggio Architects, P.C.

4

3

2

1


7

6

5

4

3

2

1

FLOOR PLAN GENERAL NOTES +42"

FLOOR PLAN KEYNOTES

1. ALL PLAN DIMENSIONS TAKEN FROM FACE OF GYP BD, MASONRY OPENING OR GRIDLINE UNLESS NOTED OTHERWISE

1

8' HIGH FIRE TREATED PLYWD BACKER BOARD - FULL WIDTH OF WALL

2

CEILING MOUNTED TRACK AND CURTAIN

3

POWER DOOR OPERATOR ACTUATOR

3. TYPICAL PARTITION TYPE TO BE 9H, UNLESS NOTED OTHERWISE. ALL COLUMN WRAP FURRING TO BE WALL TYPE 2H, UNLESS NOTED OTHERWISE.

4

3-TIER METAL STUDENT LOCKER, TYPE ML-1

4.

5

CAST GFRC COLUMN WRAP

6

PAIRED-PANEL OPERABLE PARTITION AT 27'-9" WIDE X 8'-0" HIGH

2. REFER TO CODE COMPLIANCE PLANS (A00-13 AND A00-14) FOR ALL RATED WALL LOCATIONS AND RATING REQUIREMENTS

GALV STEEL GUARDRAIL

SEE A00-12 FOR MOUNTING HEIGHTS AND WALL MOUNTED DISPLAY BOARDS

5. FOR ALL DOORS NOT SPECIFICALLY DIMENSIONED IN PLAN PROVIDE 4" FROM ADJACENT PERPENDICULAR WALL TO HM/ALUM DOOR/WINDOW FRAME, UNLESS NOTED OTHERWISE

F

Ph: 303.773.0436 | Fax: 303.773.8709 IN ASSOCIATION WITH:

8

EMERGENCY EYE WASH & SHOWER; RE: PLBG

9

6" STEEL PIPE BOLLARD, RE: CIVIL SHEET C03-04 FOR DETAILS

10

KEWAUNEE #T14W364272 WORK TABLE WITH CASTERS & EPOXY TOP, SIM TO EXCEPT 48" DEEP

11

WRAP COLUMNS UP TO BOTTOM CHORD OF ROOF JOISTS

12

LSI #5222 18 WIDE, 84" HIGH

13

KEWAUNEE LAB TABLE ITEM #T13W362472 WITH EPOXY TOP, SIM TO EXCEPT 90" LONG

14

METAL SHIPS LADDER - RE; SPECIFICATIONS

15

MOBILE BOOKSHELVES; SEE 42/A12-17

16

KEWAUNEE LAB TABLE ITEM #X90W364800-00_0B9 WITH EPOXY TOP

17

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP

18

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP, SIM TO EXCEPT 30" WIDE & 60" LONG

GUARDRAIL DETAIL

19

12" DIAMETER CONC COLUMN RE: STRUCT.

3/4" = 1'-0"

20

WALL PROTECTION PADS RE: INTERIOR ELEVATIONS

21

3X3 SQUARE GALVANIZED STEEL BOLLARD, TYPICAL AT ALL EXTERIOR OUTSWINGING DOORS SHOWN AS THUS . RE: DETAIL 5 ON SHEET A11-17

22

LSI #6290; EXCEPT 60" HIGH

23

LSI #6290; EXCEPT 48" HIGH

24

LSI #6290; EXCEPT 36" HIGH

25

LSI #6290; EXCEPT 84" HIGH

26

TEACHER DEMONSTRATION TABLE, RE: 40/A12-12

27

15' ALUMINUM TILT AND ROLL BLEACHER

28

16' WIDE x 8' TALL MARKERBOARD SURFACE APPLIED TO WALL

29

WALL MOUNTED SOUND-ABSORPTIVE PANELS FROM +12" TO +120" AFF

30

PROVIDE IN-WALL BLOCKING FOR OWNER PROVIDED CHEMICAL DISPENSING SYSTEM. VERIFY EXTENT AND LOCATION WITH OWNER.

6. ALL INTERIOR CMU PARTITIONS SHALL EXTEND TO UNDERSIDE OF FLOOR/ROOF DECK ABOVE AND BE BRACED AS PER STURTURAL DRAWINGS, UNLESS NOTED OTHERWISE

1/2" EXP MATERIAL W/ POURABLE SEALANT TYP ALL SIDES

7. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA: • CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE (SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THAN STUD WIDTH ON THE LINE. • ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED. • MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".

MIN

4"

CONCRETE SLAB - RE: STRUCTURAL

8. FOR GYP BD ON MTL STUD COLUMN WRAPS NOT SPECIFICALLY DIMENSIONED IN PLAN, STUD FRAMING SHALL BE AS TIGHT TO THE COLUMN AS ALLOWED BY SPRAY-APPLIED FIREPROOFING, MEP ROUGH-IN, STRUCTURAL CONNECTIONS, ETC

E

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

PAIRED-PANEL OPERABLE PARTITION AT 27'-3" WIDE X 8'-0" HIGH

CONC PAVING RE: CIVIL

NEW LARAMIE HIGH SCHOOL Laramie | Wyoming Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408 Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775 Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

E

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094 Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978 Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

16.4

16

15.5

13.6 1 A06-11

11' - 8"

19' - 0"

8' - 8"

2

4

A07-02

A07-10

13.1 12.9

11

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

4 A06-10

65' - 4"

19' - 4"

11.6

19' - 0"

2' - 4"

37' - 0"

13' - 0"

68' - 0"

D 2' - 0"

D

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

WW

RD OD

4' - 0" 15' - 8"

3

6' - 8"

8' - 0"

2' - 0"

8' - 0"

6' - 8"

1169-E 1' - 4"

21' - 8"

6' - 5 1/8"

14' - 8"

8D 1169A-B

1' - 4"

1169A-A

6' - 8"

6' - 8"

TYP

21

TT

4"

ISSUED FOR CONSTRUCTION

20

1208-B

8' - 4"

4"

2' - 0" 54D

1169-C

1169-B 8' - 8"

18' - 4"

2' - 8" 1169-D

2' - 0"

1169A-D

18x42 wall mntd rack

1169A-C 5' - 8"

8' - 0"

4" STONE VENEER ON 8" CMU 19' - 4"

3' - 2" 2' - 8"

C55

3' - 2 7/8"

1169A

LINE OF ROOF CANOPY ABOVE 8' - 8"

LINE OF ROOF CANOPY ABOVE

STORAGE

21' - 4"

UU

A07-10

SLOPE DOWN 8%

20' - 0"

1208-A

MATCHLINE

GALV STL GUARDRAIL ON CONC CURB AT DOCK RAMP

ITEM 2 A06-11

A08-14

QQ

VAN / TRUCK PARKING

23' - 8" CLEAR WIDTH 1

PAVING ELEVATION 96'-0"

24' - 8" ADD ALT #7: LINE OF ROOF OVERHANG ABOVE

A07-10

NN

3' - 4" 4' - 4"

8' - 0"

6' - 8"

21

6' - 8"

4"

8"

ELEVATION 100'-0"

9' - 0"

Seal:

1139

2

KEEP CLEAR

6' - 2"

EXTERIOR RECEIVING DOCK

B

1176-C

8' - 6"

GALV STL OPEN GRATE STAIR W/ HDRL

DN

SLOPE TO DRAIN DOCK LEVELER

1178-B

GAS METER

DOCK BUMPERS

SLOPE 1/8" PER FOOT

1169

5' - 3"

ELEVATION 96'-0"

8' - 9"

1180

CORRIDOR

32' - 4"

C57

EGRESS PATH

10' - 0"

AREA DRAIN RE: CIVIL

9

KEEP CLEAR

A07-16

ADD ALT #7

AUXILIARY GYM

DESCRIPTION

EGRESS PATH

9" BLACK PAINTED LETTERING ON 12" WIDE RED PAINTED STRIPE

1' - 4"

DATE

A04-21E

37

30' - 0"

13

#

2

15

B

C

39

1206

11' - 4"

CORRIDOR

RR

EXTERIOR EGRESS PASSAGE 36" GALV STL PIPE RAILING

SEE 1 / A04-21G

MATCHLINE

C

SEE 1 / A04-21C

1208

KEEP CLEAR

48' - 0"

VESTIBULE

48' - 5 5/8"

PAVING ELEVATION 100'-0" RE: CIVIL PLANS FOR ALL SURROUNDING GRADING

10' - 0 3/4"

A07-10

28' - 0 3/8"

RECEIVING 1176 1176-A 11' - 8"

52B

MECH

4' - 6"

20

2 A07-01

4' - 0"

1169-F

MB-1

D

12' - 0"

A

3' - 4"

2

MATCHLINE

1167-G

1167-F

F

B

LBA Project Date

A07-01

CORRIDOR 1174 1167-H

A

E

1139

4

SEE 1 / A04-21D 1167-E

G

LL CORRIDOR

FE

A12-11 1176A

1176A

52C

OFFICE TB-1

12' - 0"

SIM

52C

1169-A

4' - 8" 1' - 10 1/4" 52C

33 A10-01

4' - 0"

Key Plan: C

1178

2H

1178-A

REFER TO SHEET A08-13 FOR CROSS COURT STRIPING PLANS

4' - 2"

MATCHLINE

LL.5

SEE 1 / A04-21F

REFER TO SHEET A08-11 FOR COMPETITION COURT STRIPING PLANS

12' - 8"

1

51C

1176-B

13' - 6"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

7

CIP CONCRETE RETAINING WALL - RE: STRUCTURAL

2

Lantz-Boggio Architects, P.C.

A

2012.32 15 JANUARY 2014

LEVEL 01 FLOOR PLAN - AREA E

NORTH

2 A07-02

1 7

6

A04-21E

LEVEL 01 FLOOR PLAN, AREA E 1/8" = 1'-0" 5

4

3

2

1


7

6

5

4

3

2

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEYNOTES

1. ALL PLAN DIMENSIONS TAKEN FROM FACE OF GYP BD, MASONRY OPENING OR GRIDLINE UNLESS NOTED OTHERWISE

17.2

16.4

16

8' HIGH FIRE TREATED PLYWD BACKER BOARD - FULL WIDTH OF WALL

2

CEILING MOUNTED TRACK AND CURTAIN

3

POWER DOOR OPERATOR ACTUATOR

3. TYPICAL PARTITION TYPE TO BE 9H, UNLESS NOTED OTHERWISE. ALL COLUMN WRAP FURRING TO BE WALL TYPE 2H, UNLESS NOTED OTHERWISE.

4

3-TIER METAL STUDENT LOCKER, TYPE ML-1

4.

5

CAST GFRC COLUMN WRAP

6

PAIRED-PANEL OPERABLE PARTITION AT 27'-9" WIDE X 8'-0" HIGH

7

PAIRED-PANEL OPERABLE PARTITION AT 27'-3" WIDE X 8'-0" HIGH

8

EMERGENCY EYE WASH & SHOWER; RE: PLBG

9

6" STEEL PIPE BOLLARD, RE: CIVIL SHEET C03-04 FOR DETAILS

10

KEWAUNEE #T14W364272 WORK TABLE WITH CASTERS & EPOXY TOP, SIM TO EXCEPT 48" DEEP

11

WRAP COLUMNS UP TO BOTTOM CHORD OF ROOF JOISTS

12

LSI #5222 18 WIDE, 84" HIGH

13

KEWAUNEE LAB TABLE ITEM #T13W362472 WITH EPOXY TOP, SIM TO EXCEPT 90" LONG

Laramie | Wyoming

14

METAL SHIPS LADDER - RE; SPECIFICATIONS

15

MOBILE BOOKSHELVES; SEE 42/A12-17

16

KEWAUNEE LAB TABLE ITEM #X90W364800-00_0B9 WITH EPOXY TOP

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

7 A08-16

17

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP

18

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP, SIM TO EXCEPT 30" WIDE & 60" LONG

19

12" DIAMETER CONC COLUMN RE: STRUCT.

20

WALL PROTECTION PADS RE: INTERIOR ELEVATIONS

21

3X3 SQUARE GALVANIZED STEEL BOLLARD, TYPICAL AT ALL EXTERIOR OUTSWINGING DOORS SHOWN AS THUS . RE: DETAIL 5 ON SHEET A11-17

22

LSI #6290; EXCEPT 60" HIGH

23

LSI #6290; EXCEPT 48" HIGH

24

LSI #6290; EXCEPT 36" HIGH

25

LSI #6290; EXCEPT 84" HIGH

26

TEACHER DEMONSTRATION TABLE, RE: 40/A12-12

27

15' ALUMINUM TILT AND ROLL BLEACHER

28

16' WIDE x 8' TALL MARKERBOARD SURFACE APPLIED TO WALL

29

WALL MOUNTED SOUND-ABSORPTIVE PANELS FROM +12" TO +120" AFF

30

PROVIDE IN-WALL BLOCKING FOR OWNER PROVIDED CHEMICAL DISPENSING SYSTEM. VERIFY EXTENT AND LOCATION WITH OWNER.

1196

1185-B

1193 52C

52C

MEN'S PE LOCKERS

1185-A

52C

1185

PE OFFICE 1193

29' - 9 1/2"

1193A

54C

3' - 11 1/4"

TOILET

27

Ph: 303.773.0436 | Fax: 303.773.8709 IN ASSOCIATION WITH:

1183

1177

23 A08-21

NEW LARAMIE HIGH SCHOOL

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775 Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

1175B

JJ

1175

1175

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

1173A

WOMEN'S ATHLETIC LOCKERS

1173-A

1173

27

4' - 0"

52C

52C

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

PE OFFICE 1171

1171A

1 A07-12

27

13

A08-15

40

A07-13 D

36 1/2" AFF

37

STORAGE RACKS

16 27

9 2/8" BASE

ICE MACHINE

1' - 0"

3' - 8"

4

1171A

REHAB TABLE

1 1/2" WASTE 9 2/8" BASE

SPORTS MEDICINE

9" STEP 7' - 10 1/2"

24' - 8 1/2"

A12-11

D

39

1195B

POOL 1188

3

4' - 6"

IS25

4' - 8 1/2" 1' - 2 7/8" 1197-C

27

7' - 3 5/8"

RA GRILLE

22' - 0"

1195A

6' - 8"

IS24

27

OFFICE

4' - 8"

EE.2

8' - 8"

A07-13

4' - 0"

8"

OFFICE

STOR

1197B

1197A 1197A

1197B

2' - 8"

7' - 4"

6' - 8"

1' - 11 5/8"

ISSUED FOR CONSTRUCTION

1197-A

REFER TO SWIMMING POOL DRAWINGS FOR DETAILS EQUIPMENT AND ANCHOR LOCATIONS

1180

1195B

9H ABOVE HOLLOW METAL GLAZING ASSEMBLY

27

1195A

DECK MOUNTED STANCHION SLEEVE, RE: POOL DWGS

31' - 11 1/2" TB-1

52C 9H ABOVE HOLLOW METAL WINDOW ASSEMBLY

22' - 6 3/4"

2 A07-13

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

CORRIDOR 52C

TB-1

GG

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

TOILET

52C

27

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

1171

1175A-A

1175A

VEST

ENTRY VEST

1173-B

SHOWERS 1173A

51C

WOMEN'S TOILET

E

7' - 4"

1177B 5 A06-11

1177-B

1177B

27

MATCHLINE

VEST 1175A-B

1m

1m

3m

3m

62C

DATA SEE 1 / A04-21D

WOMEN'S PE LOCKERS

1177-A

27

E

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

1193A

3m = 10'-0"

5m = 16'-5"

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

52C

ADD ALT. No. 5: 3m AND 5m HIGH DIVE PLATFORM, WARMING SHOWERS, STAIRS, LADDERS AND ASSOCIATED RAILINGS

LL.5

8. FOR GYP BD ON MTL STUD COLUMN WRAPS NOT SPECIFICALLY DIMENSIONED IN PLAN, STUD FRAMING SHALL BE AS TIGHT TO THE COLUMN AS ALLOWED BY SPRAY-APPLIED FIREPROOFING, MEP ROUGH-IN, STRUCTURAL CONNECTIONS, ETC

1183

A07-13

52C

27

CC

3' - 4"

27

10' - 3 1/2" 5' - 4 1/2"

46' - 0"

27

RE: LEVEL 2 FLOOR PLAN FOR WINDOW DIMENSIONS

26' - 0"

4' - 8" C

EWC

7' - 3 5/8"

RA GRILLE

15' - 0" TYP

C

8' HIGH MIRROR

FITNESS/ WEIGHT

27

14' - 0"

1180

1197

ITEM

IS23

2' - 0"

1188-D

AA

#

DATE

DESCRIPTION

16' - 0"

POOL DECK TRENCH DRAIN, RE: PLBG DRAWINGS

CJ

27

27

CJ

27

22' - 0"

CJ

8' - 8"

CJ

A07-15

2' - 0"

1197-B

C1

25 A11-18 1 A08-40

2H

C1

C8

C8

UP

STAIR ST-11.1

5

C8

4' - 2"

14' - 0"

TYP

COMMONS

2' - 8"

1002-D

1002

2' - 0"

1' - 8"

17' - 0"

2' - 0"

C69

15' - 4"

C68

2' - 0"

15' - 4"

2' - 0"

Key Plan: 3

15' - 4"

E

F

D

C

A07-15

C53 TYP

G

C8

C8

C8

C.5

2

B

A07-14

1 2' - 8"

A07-14

1002-C

C

Seal:

15' - 8"

2 A07-15

B

5 A09-28

4' - 0"

16' - 0"

2' - 0"

15' - 4" C68

1

15' - 4"

2' - 0"

A

15' - 4" C8

C53 TYP

C.8

LBA Project Date 2' - 8"

A07-02

2' - 0"

4' - 2"

4 A06-11

VENDING MACHINES (NIC)

1

2' - 0"

B

9' - 0 5/8"

IS23

54D-GF

DC-F-1 TYPICAL OF (5)

1002-E

16' - 0"

CJ

1188-A

6' - 1" 8' - 8 3/8"

9' - 4"

54D-GF 8' - 8"

22' - 0"

CJ

1188-B 4' - 8"

4' - 0"

16' - 0"

A 2' - 0"

15' - 4" C53 TYP

1 A06-12

SEE 1 / A04-21D

A

MATCHLINE

B

27

5' - 4"

27

15' - 0"

CJ

A

9' - 10"

27 A11-18

2' - 8"

12' - 8"

1' - 3 1/2"

3' - 4"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

11' - 10 3/8"

1188-C 1

1187A-A

1190-A

1192

1194

1188A

SEE 1 / A04-21G

7. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA: • CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE (SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THAN STUD WIDTH ON THE LINE. • ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED. • MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".

1187A

1187B

1185A

6. ALL INTERIOR CMU PARTITIONS SHALL EXTEND TO UNDERSIDE OF FLOOR/ROOF DECK ABOVE AND BE BRACED AS PER STURTURAL DRAWINGS, UNLESS NOTED OTHERWISE

SEE 1 / A04-21E

TOILET

MEN'S SHOWERS

NNMATCHLINE

MATCHLINE

A07-02

F

SEE A00-12 FOR MOUNTING HEIGHTS AND WALL MOUNTED DISPLAY BOARDS

5. FOR ALL DOORS NOT SPECIFICALLY DIMENSIONED IN PLAN PROVIDE 4" FROM ADJACENT PERPENDICULAR WALL TO HM/ALUM DOOR/WINDOW FRAME, UNLESS NOTED OTHERWISE

1

Lantz-Boggio Architects, P.C.

1

2. REFER TO CODE COMPLIANCE PLANS (A00-13 AND A00-14) FOR ALL RATED WALL LOCATIONS AND RATING REQUIREMENTS

22

1

2012.32 15 JANUARY 2014

LEVEL 01 FLOOR PLAN - AREA F

NORTH

21

22

1 7

20

19

17.9

17

15.9

A04-21F

LEVEL 01 FLOOR PLAN, AREA F 1/8" = 1'-0" 6

5

4

3

2

1


7

6

5

4

3

2

1

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEYNOTES

1. ALL PLAN DIMENSIONS TAKEN FROM FACE OF GYP BD, MASONRY OPENING OR GRIDLINE UNLESS NOTED OTHERWISE

1

8' HIGH FIRE TREATED PLYWD BACKER BOARD - FULL WIDTH OF WALL

2

CEILING MOUNTED TRACK AND CURTAIN

3

POWER DOOR OPERATOR ACTUATOR

3. TYPICAL PARTITION TYPE TO BE 9H, UNLESS NOTED OTHERWISE. ALL COLUMN WRAP FURRING TO BE WALL TYPE 2H, UNLESS NOTED OTHERWISE.

4

3-TIER METAL STUDENT LOCKER, TYPE ML-1

4.

5

CAST GFRC COLUMN WRAP

6

PAIRED-PANEL OPERABLE PARTITION AT 27'-9" WIDE X 8'-0" HIGH

2. REFER TO CODE COMPLIANCE PLANS (A00-13 AND A00-14) FOR ALL RATED WALL LOCATIONS AND RATING REQUIREMENTS

SEE A00-12 FOR MOUNTING HEIGHTS AND WALL MOUNTED DISPLAY BOARDS

5. FOR ALL DOORS NOT SPECIFICALLY DIMENSIONED IN PLAN PROVIDE 4" FROM ADJACENT PERPENDICULAR WALL TO HM/ALUM DOOR/WINDOW FRAME, UNLESS NOTED OTHERWISE

F

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111 Ph: 303.773.0436 | Fax: 303.773.8709 IN ASSOCIATION WITH:

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

6. ALL INTERIOR CMU PARTITIONS SHALL EXTEND TO UNDERSIDE OF FLOOR/ROOF DECK ABOVE AND BE BRACED AS PER STURTURAL DRAWINGS, UNLESS NOTED OTHERWISE 7. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA: • CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE (SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THAN STUD WIDTH ON THE LINE. • ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED. • MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR". 8. FOR GYP BD ON MTL STUD COLUMN WRAPS NOT SPECIFICALLY DIMENSIONED IN PLAN, STUD FRAMING SHALL BE AS TIGHT TO THE COLUMN AS ALLOWED BY SPRAY-APPLIED FIREPROOFING, MEP ROUGH-IN, STRUCTURAL CONNECTIONS, ETC

7

PAIRED-PANEL OPERABLE PARTITION AT 27'-3" WIDE X 8'-0" HIGH

8

EMERGENCY EYE WASH & SHOWER; RE: PLBG

9

6" STEEL PIPE BOLLARD, RE: CIVIL SHEET C03-04 FOR DETAILS

10

KEWAUNEE #T14W364272 WORK TABLE WITH CASTERS & EPOXY TOP, SIM TO EXCEPT 48" DEEP

11

WRAP COLUMNS UP TO BOTTOM CHORD OF ROOF JOISTS

NEW LARAMIE HIGH SCHOOL

12

LSI #5222 18 WIDE, 84" HIGH

Laramie | Wyoming

13

KEWAUNEE LAB TABLE ITEM #T13W362472 WITH EPOXY TOP, SIM TO EXCEPT 90" LONG

14

METAL SHIPS LADDER - RE; SPECIFICATIONS

15

MOBILE BOOKSHELVES; SEE 42/A12-17

16

KEWAUNEE LAB TABLE ITEM #X90W364800-00_0B9 WITH EPOXY TOP

17

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP

18

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP, SIM TO EXCEPT 30" WIDE & 60" LONG

19

12" DIAMETER CONC COLUMN RE: STRUCT.

20

WALL PROTECTION PADS RE: INTERIOR ELEVATIONS

21

3X3 SQUARE GALVANIZED STEEL BOLLARD, TYPICAL AT ALL EXTERIOR OUTSWINGING DOORS SHOWN AS THUS . RE: DETAIL 5 ON SHEET A11-17

22

LSI #6290; EXCEPT 60" HIGH

23

LSI #6290; EXCEPT 48" HIGH

24

LSI #6290; EXCEPT 36" HIGH

25

LSI #6290; EXCEPT 84" HIGH

26

TEACHER DEMONSTRATION TABLE, RE: 40/A12-12

27

15' ALUMINUM TILT AND ROLL BLEACHER

28

16' WIDE x 8' TALL MARKERBOARD SURFACE APPLIED TO WALL

29

WALL MOUNTED SOUND-ABSORPTIVE PANELS FROM +12" TO +120" AFF

30

PROVIDE IN-WALL BLOCKING FOR OWNER PROVIDED CHEMICAL DISPENSING SYSTEM. VERIFY EXTENT AND LOCATION WITH OWNER.

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408 Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775 Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

E

E

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094 Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978 Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187 Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

D

D

22

1

18

1 A06-11

A07-02

17.2

16.4

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

16

12' - 0"

3' - 8"

1211

FAMILY TOILET

7' - 0"

1207B-A

1209B-A 52C

VEST

VEST

1209B

1207B

FE

33' - 0"

VEST

STORAGE

VESTIBULE

1201D

1202

1199D

1199-B C

1208-B

52C

11' - 4"

1207-A

1212

1212-A

1209-A

3' - 4"

CONCESSIONS

1201-B

52C

1209-B

1211

33 A12-10

4' - 8"

1207-B

1' - 4"

13' - 4"

1212-C

1212-B

UU C

5' - 4"

21 TYP

5' - 4"

MATCHLINE

12' - 0"

C52

1207B-B

4' - 0"

4' - 0"

12' - 0"

1209B-B

1' - 0"

DRINKING FOUNTAIN

A07-11

1199D

C52

A07-11 4' - 0" 1' - 8"

37 A08-20

1

1202

2

1201D

C52

SEE 1 / A04-21E

ISSUED FOR CONSTRUCTION

HB

62C

SLOPE FLOOR 1/8" PER FOOT TO OVERHEAD DOOR

1' - 4"

CUSTODIAL STORAGE

1214

MENS TOILET

WOMENS TOILET

1209

1207

64C 62C

A07-11

31' - 3"

17' - 4"

1190-B

A07-11

1201C

1199-A

B

CORRIDOR

6

Seal:

1204 52C

ELEVATOR

1191

EL-03

LAUNDRY

1196

TOILET 23 A08-21

1196

VEST 6' - 8"

10' - 0"

7' - 4"

8' - 0"

7' - 4"

54C

1' - 4"

28 A11-18

40C

ENTRY VEST

1187 A

1187

LBA Project Date

MEN'S PE LOCKERS

1185A

1185

A

1185-A

1

1 1/2"

D

B

1187A

1187B

1185A

F

CD-1

MEN'S SHOWERS

1189B

E C

1182

HB

62C

STAFF

CW-1

G

1182

1189B

EWC

Key Plan:

1189

1189-A

1179

1179

MEN'S ATHLETIC LOCKERS

VEST

52C

52C

1193

1194

JAN 21 A09-10

1185-B

52C

64C

1200

1189-B

1196A

1194A

OFFICIALS

1200

2' - 8"

34' - 8"

52C

MB-2

3' - 10"

EL-03.1

1198-A RA GRILLE

MB-2

1191 52C

1187A-B

1196A

ELEC

1187A-A

TOILET

1194A

1194

RA

6' - 8"

TO 8' AFF 10' - 4"

SURGE PIT 91'-3"

52C 8' - 0"

1192

1 1/2"

1188-C

BACKWASH PIT 95'-0"

1190-A 12' - 8"

TOILET

PUMP PIT 95'-0"

FE

1188A

SEE 1 / A04-21F

29 A08-20

1192

62C

1188A

NN MATCHLINE

52C

4' - 4"

7' - 8"

STORAGE

3/8" STL PLATE PAINT

5' - 9 5/8"

+18" 9' - 2"

FD

8"

12' - 6 1/4"

52C

EWC

ELEVATOR CONTROL ROOM

5' - 4"

POOL STORAGE

1198

CORRIDOR

STAIR +6"

1199C

A07-11

3' - 6"

UP

3' - 4" 2' - 8" 3' - 4"

ST-13.1

31

FD

1198-B

ST-13.1

7' - 4"

3' - 4"

STAIR

4 A09-26

1190

ST-12.1

52C

54C

6' - 8 3/4"1202-B

8' - 0"

62C

1190-D

1190-C

POOL EQUIPMENT

62C

STARTER BLOCK STORAGE RACK RE: 2/A04-21G

62C FD

2' - 0"

7' - 8"

52C

4"

1208

EWC 7' - 8"

FE

8' - 0"

VESTIBULE

JAN 1203

6' - 8"

1209A

64C

4

VESTIBULE 1201C

1201E

1207A

1202

3

ST-12.1

QQ

A

1199B

DESCRIPTION

VESTIBULE

HOME LOCKER ROOM

1199C

DATA

CORRIDOR 16' - 1"

11/4" STL PIPE (CAPPED) AT 30" O.C. WELD TO STL PLATE. GRIND ALL WELDS SMOOTH. PAINT.

SHOWERS

1201B

2' - 0"

1209A

64C

1201-A

VESTIBULE

1207A

1213

11' - 4"

29 A11-18

1202-A

60°

SHOWERS

1201E

VESTIBULE

1207-C

1209-C

52C

1210 1210

13' - 4"

B

W8

1199A

DATE

1206

RR

FACE OF CMU

1201A

#

CORRIDOR

FAMILY TOILET 64C

REMOTE CO2 FILL STATION

TOILETS

10' - 0"

32 A10-01 ABOVE

1 A09-26

TOILETS

1199

1213

1214-A 5 A06-11

1201A

1201

EXTERIOR STORAGE

1214-B

VISITOR LOCKER ROOM

HB

ITEM

1208-A

52C

100'-3 1/2"

100'-0"

1203

24' - 8"

51' - 0"

62C

11"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

Lantz-Boggio Architects, P.C.

2012.32 15 JANUARY 2014

LEVEL 01 FLOOR PLAN - AREA G

A07-02

3/8" Ø x 5" EMBED EXPANSION ANCHOR @ 24 O.C. MAX.

2 A07-16

NOTE: VERIFY STL PIPE DIA. AND SPACING W/ STARTER BLOCK MANUF. PRIOR TO FABRICATION.

2 7

NORTH

WALL MTD STEEL PIPE DETAIL

1

1 1/2" = 1'-0" 6

5

A04-21G

LEVEL 01 FLOOR PLAN, AREA G 1/8" = 1'-0" 4

3

2

1


7

6

5

4

3

2

1

Lantz-Boggio Architects, P.C. 5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111 Ph: 303.773.0436 | Fax: 303.773.8709 IN ASSOCIATION WITH:

F

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

NEW LARAMIE HIGH SCHOOL Laramie | Wyoming

22

18

17.2

16.416 15.5

13.6 13.112.9

11.6 11

10

9

8

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

6.3

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

WW UU

E

SS

M

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

ROOF BELOW

E

TT

RR QQ

xEE

OPEN TO BELOW STAIR

PP MM.9

OPEN TO GYM BELOW

UP

ELEVATOR

OPEN TO BELOW

LOBBY

WRESTLING

NN

POOL CONTROL ROOM

MM.6

LL.5

MECHANICAL WELL

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

MM

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

LL OPEN TO STAGE BELOW

OPEN TO BELOW

JJ.7 JJ HH.3

KK

x9.2x9.3

WEST MECHANICAL ROOM

OPEN TO POOL BELOW

GG.3

HH.4

OPEN TO THEATER HOUSE BELOW

POOL BLEACHERS

EAST MECHANICAL ROOM

OPEN TO GYM BELOW

EE.2

FF

EE

AV STOR

D

MEDIA CENTER OFFICE/ CONFERENCE/ WORKROOM CLASSROOM

CC

BB

ELEVATOR

AA A B

AA.1 DN

STAIR

AA.1 A

x x14

CORRIDOR

UP

6

DN

C

x10 OPEN TO BELOW

C.8

20

19

17.9

17

xAA

MEDIA LAB

D

D.5 21

x8 xCC xBBx7

OPEN TO BELOW

C.5

15

x6

x5

x4

x3 x2

CLASSROOM

E

15.9

14.2

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

DD

BB.5

STORAGE

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

HH.3 HH

DN

STAIR

GG

D

Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

x9

ROOF BELOW

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022

CLASSROOM CLASSROOM

ISSUED FOR CONSTRUCTION x1

CLASSROOM

bb

CLASSROOM

13

SPECIAL ED CLASSROOM

HEAD END

IT TECH

F ROOF BELOW

WORKROOM/ PLANNING/ STORAGE

G

TLT APASSISTANT PRINCIPAL SEC'Y

R&D

C

H J

xA xB

DISTRIBUTED MEDIA / LEARNING STREET

xC xD

SMALL GROUP

C

CLASSROOM

ELEC

FD

STAIR

xE SP ED OFFICE GUIDANCE CLASSROOM STAFF DEVELOPMENT

xF

CLASSROOM

CLASSROOM

WOMEN'S TOILET

VESTIBULE DATA JAN

L M

OFFICE

K.6 4

SCIENCE

PREP

12.8

12

DATE

DESCRIPTION

1

SCIENCE

10.8

Q R

R&D PREP

xH T

MEN'S TOILET

VESTIBULE JAN R&D

CLASSROOM

WOMEN'S TOILET

CLASSROOM

B

CLASSROOM

xJ

DATA

x4.1

VESTIBULE

U V

CLASSROOM R&D SMALLSTORAGE ELEC GROUP

xK xL

STADIUM SEATING

CONFERENCE

TLT DISTRIBUTED MEDIA / LEARNING STREET

B

Seal:

SP ED GUIDANCE OFFICE

xJ.5

xM

2

#

PREP

SCIENCE

14 x15.3

3

ITEM

N N.2

SCIENCE

N.5 P

K xG

MEN'S TOILET

VESTIBULE

W

STAIR

FD

WORKROOM/ PLANNING/ STORAGE

ROOF BELOW

SPECIAL ED CLASSROOM

X

CLASSROOM

STAIR

CLASSROOM CLASSROOM

CLASSROOM

x15.3 x15

Key Plan:

Y

CLASSROOM R&D

G

E

F

D

C

x14.1

x13

x12

x11

x9.1

B

x7.3

EXTENT OF PROJECT ENHANCEMENTS - SEE SCHEDULE IN SPECIFICATIONS - REFER TO SHEET A00-37 & A00-38 FOR ADDITIONAL INFORMATION

x4.1 8 7 6.2

A

LBA Project Date

5.2 5

A

A

2012.32 15 JANUARY 2014

OVERALL LEVEL 02 FLOOR PLAN

NORTH

0'

1 7

6

16'

32'

A04-22

OVERALL LEVEL 02 FLOOR PLAN 1/32" = 1'-0" 5

64'

4

3

2

1


7

6

5

4

3

2

1

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEYNOTES

1. ALL PLAN DIMENSIONS TAKEN FROM FACE OF GYP BD, MASONRY OPENING OR GRIDLINE UNLESS NOTED OTHERWISE

8' HIGH FIRE TREATED PLYWD BACKER BOARD - FULL WIDTH OF WALL

2

CEILING MOUNTED TRACK AND CURTAIN

3

POWER DOOR OPERATOR ACTUATOR

3. TYPICAL PARTITION TYPE TO BE 9H, UNLESS NOTED OTHERWISE. ALL COLUMN WRAP FURRING TO BE WALL TYPE 2H, UNLESS NOTED OTHERWISE.

4

3-TIER METAL STUDENT LOCKER, TYPE ML-1

4.

5

CAST GFRC COLUMN WRAP

6

PAIRED-PANEL OPERABLE PARTITION AT 27'-9" WIDE X 8'-0" HIGH

7

PAIRED-PANEL OPERABLE PARTITION AT 27'-3" WIDE X 8'-0" HIGH

8

EMERGENCY EYE WASH & SHOWER; RE: PLBG

9

6" STEEL PIPE BOLLARD, RE: CIVIL SHEET C03-04 FOR DETAILS

10

KEWAUNEE #T14W364272 WORK TABLE WITH CASTERS & EPOXY TOP, SIM TO EXCEPT 48" DEEP

11

WRAP COLUMNS UP TO BOTTOM CHORD OF ROOF JOISTS

12

LSI #5222 18 WIDE, 84" HIGH

13

KEWAUNEE LAB TABLE ITEM #T13W362472 WITH EPOXY TOP, SIM TO EXCEPT 90" LONG

Laramie | Wyoming

14

METAL SHIPS LADDER - RE; SPECIFICATIONS

15

MOBILE BOOKSHELVES; SEE 42/A12-17

3

16

KEWAUNEE LAB TABLE ITEM #X90W364800-00_0B9 WITH EPOXY TOP

A07-01

17

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

18

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP, SIM TO EXCEPT 30" WIDE & 60" LONG

19

12" DIAMETER CONC COLUMN RE: STRUCT.

20

WALL PROTECTION PADS RE: INTERIOR ELEVATIONS

21

3X3 SQUARE GALVANIZED STEEL BOLLARD, TYPICAL AT ALL EXTERIOR OUTSWINGING DOORS SHOWN AS THUS . RE: DETAIL 5 ON SHEET A11-17

22

LSI #6290; EXCEPT 60" HIGH

23

LSI #6290; EXCEPT 48" HIGH

24

LSI #6290; EXCEPT 36" HIGH

25

LSI #6290; EXCEPT 84" HIGH

26

TEACHER DEMONSTRATION TABLE, RE: 40/A12-12

27

15' ALUMINUM TILT AND ROLL BLEACHER

28

16' WIDE x 8' TALL MARKERBOARD SURFACE APPLIED TO WALL

29

WALL MOUNTED SOUND-ABSORPTIVE PANELS FROM +12" TO +120" AFF

30

PROVIDE IN-WALL BLOCKING FOR OWNER PROVIDED CHEMICAL DISPENSING SYSTEM. VERIFY EXTENT AND LOCATION WITH OWNER.

2. REFER TO CODE COMPLIANCE PLANS (A00-13 AND A00-14) FOR ALL RATED WALL LOCATIONS AND RATING REQUIREMENTS

SEE A00-12 FOR MOUNTING HEIGHTS AND WALL MOUNTED DISPLAY BOARDS

5. FOR ALL DOORS NOT SPECIFICALLY DIMENSIONED IN PLAN PROVIDE 4" FROM ADJACENT PERPENDICULAR WALL TO HM/ALUM DOOR/WINDOW FRAME, UNLESS NOTED OTHERWISE

F

6. ALL INTERIOR CMU PARTITIONS SHALL EXTEND TO UNDERSIDE OF FLOOR/ROOF DECK ABOVE AND BE BRACED AS PER STURTURAL DRAWINGS, UNLESS NOTED OTHERWISE 7. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA: • CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE (SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THAN STUD WIDTH ON THE LINE. • ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED. • MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".

7

8 34' - 8"

5.2

12' - 0"

34' - 8"

24

COMBUSTIBLE STORAGE CABINET

PREP

A12-12

MB-1

2051A

SEE 1 / A04-22B 2051A-B

P

FH-2

8

IS31

A12-12

41 O.H.

CORRIDOR 2037

17

16

A12-12

IN ASSOCIATION WITH:

NEW LARAMIE HIGH SCHOOL

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775 Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

16

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

41

Q 17

33

4 A06-14

BASE BID

ADD ALT #13

36

SCIENCE

A12-16

2053

5 A06-12 17

12.8

x15.3

12

ELEVATOR

EL-01.2

EL-01

10.8

2054A

17

52D

17

2053-B

4' - 0"

10' - 0"

4' - 0"

10' - 0"

2054-A

10' - 0"

4' - 0"

10' - 0"

10' - 0"

2' - 0"

2' - 0"

MEN'S TOILET 30

WP

18

2085

2085A

1' - 2"

2083

CORRIDOR

ROOF ACCESS

2067

2089A

" -0 2 -R DC

A12-11

10' - 0"

7

2063

xK

7 A09-25 OH

2074

2077-A

A07-33 5

TYP

4

DN

2073

C9

3' - 4"

IS5

9H -1 TB

CLOSET

2H

MB-2

W ITEM

11

#

DATE

DESCRIPTION

33 IS33

A12-11

WORKROOM/ PLANNING/ STORAGE

19

11

2H

TRENCH DRAIN RE: PLBG PLANS FE

1' - 0"

O.H. 4

A12-11

11

CORRIDOR

A12-11

2088

2090 37

2 A07-32

A12-11

A12-14

20

11

Y

2

10' - 0"

4' - 0" 28' - 0"

A07-30

10' - 0"

8' - 0"

IS27

7

34

1 A07-32

R&D

37

2064 4' - 0"

ADD ALT #13

x13

A12-11

10' - 0"

4' - 0" 28' - 0"

3

10' - 0"

TRENCH DRAIN RE: PLBG PLANS

4' - 0"

1

10

10' - 0"

4' - 0" 28' - 0"

A07-30

4' - 0"

10' - 0"

x11

A07-32

10' - 0"

D

B

A

11

ROOF BELOW 2

x9.1 ADD ALT #13

F

4 4' - 0" 28' - 0"

2 A06-15

E

8

10' - 0"

TYP UON

A

G

C

2064-A

A07-30

x12

Key Plan:

5' - 0"

4' - 0"

2092

8' - 0"

10' - 0"

5' - 0"

x14.1

33

11

37

A07-30 ADD ALT #13

Seal:

CLASSROOM 4' - 0" 28' - 0"

4

B

CLASSROOM

7

6' - 8"

10' - 0"

IS27

2092

8

4' - 0"

1 A06-14

FE

2068

CLASSROOM

28' - 0"

IS26

2086

10' - 0"

10' - 0"

X

2075

CLASSROOM 8

ROOF BELOW

2064-B

2090-B 2090-A

7

37

4' - 0"

1' - 0"

2088 A12-11

24' - 4 1/2"

2075

19H

10' - 0"

IS6

ROOF BELOW

1' - 6"

2084

C3

8' - 0"

2082

37

C9

CORRIDOR 7' - 6"

ST-06.2

A12-11

2058-B

5' - 0"

1' - 0"

2 A09-24

15

2086

CLASSROOM

x15

A12-14

2093-A

C9

37

x15.3

2093A 26

32

1' - 0"

2H

2084-A

STAIR

9' - 4"

C5

2093

1' - 0"

2H

8

22' - 8"

ST-05.2

2093-B

15

2084-B

SPECIAL ED CLASSROOM

B

STAIR

2065

2082

ST-06.2

DN

V

2058

2093A

2078

6

xM

10

R&D

CORRIDOR 2070

TLT

15

1' - 0" 4

IS33

23 A08-22

FD

IS3

2H

OH

30' - 8 1/8"

2065

C9

3 A09-22

8

2058-A

VDC

CONFERENCE

2093B

DISTRIBUTED MEDIA / LEARNING STREET

2076

14

1' - 0"

C

-2 MB

10

A12-11

STADIUM SEATING

1' - 8" F.O. STUD

2091-B

LOW WD-4 BOOKSHELVES

2067

EWC

1

2091

DISTRIBUTED MEDIA / LEARNING STREET

3' - 10 1/4 "

2089

SMALL GROUP

2077-B

CORRIDOR

ELEC

4

DC-R-1 DC-R-1 8' - 2" 2' - 0"

4

9H

STORAGE

2H

ISSUED FOR CONSTRUCTION

U

WP

DN

4'

2091-A

4' - 0"

C9

1" '-

MB-2

2089A

2071

2054-B

16 A11-17

UP

2077

2063

CORRIDOR

2089

10' - 0"

CLASSROOM

IS4

2093B

2079

2081-A

3H

TYP

MECH CHASE

2087 2087

2085

MB-2

x4.1 9' - 6 1/2"

MB-1

4' - 0"

WAITING

A07-35 22 A11-14

A07-31

7' - 4"

GUIDANCE

SP ED OFFICE

7' - 3 1/4"

FE

19Q

1' - 0"

1

xL

1

2081-B

ROOF BELOW

TB-1

1' - 0"

18

5' - 0"

2083

2 A06-14

2061A

8' - 0"

CLASSROOM

2081

10' - 0"

CLASSROOM

2061

7

21

18

2061A

8

BASE BID

C

VESTIBULE

2061

8

13 A08-22

5' - 0"

A12-11

18

2059

8' - 0"

A12-11

35

2059

WOMEN'S TOILET

A07-33

IS29

DATA

2' - 1"

10' - 0" 4' - 0"

7

1

1

° 80

1 A06-13

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

18

5' - 0"

37

55' - 6"

ADD ALT No. 13

11' - 4"

D 26

COW; TYP (NIC)

23

A12-11

FH-2

2057

JAN

1

2079 37

4

8

A12-14

CLASSROOM 2

xJ.5

2054 18

2057

2 A06-13

1' - 6 1/2"

8' - 0"

T

2055A

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

R&D

1' - 0"

2055A

2055

D

VESTIBULE

2055

4' - 0"

R

SB-1

1' - 0"

28' - 0"

4' - 0"

TB-1

FLAM CAB

25' - 7 1/4"

10' - 0"

A12-14

32' - 2 1/4"

xH

7' - 0"

28' - 0"

19 A09-10

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

5 A06-14

FE

R&D PREP

42

S 33' - 0"

MB-1

3' - 0"

2"

14

17

1' - 0"

3 A06-14

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

16

16

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

2052-B

IS31 22

23

34

21

17

Ph: 303.773.0436 | Fax: 303.773.8709

E

32

2052

2053-A

26

37 A11-14

SCIENCE

2H 1' - 0"

FE

SEE 1 / A04-22B

16

3' - 8"

20

E

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

MATCHLINE

1' - 0"

MATCHLINE

0° 10

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

8. FOR GYP BD ON MTL STUD COLUMN WRAPS NOT SPECIFICALLY DIMENSIONED IN PLAN, STUD FRAMING SHALL BE AS TIGHT TO THE COLUMN AS ALLOWED BY SPRAY-APPLIED FIREPROOFING, MEP ROUGH-IN, STRUCTURAL CONNECTIONS, ETC

9.3

Lantz-Boggio Architects, P.C.

1

A07-31

6' - 7 3/8 "

ADD ALT #13

x7.3

1 A06-15

5

A

12' - 0"

2012.32 15 JANUARY 2014

LEVEL 02 FLOOR PLAN - AREA A

A07-32

BASE BID 34' - 8"

4' - 4"

3

A07-32 BASE BID

8' - 0"

LBA Project Date

WRAP COLUMN ALL FOUR SIDES AT 8' AFF TO 12' AFF

11

14' - 4"

20' - 4"

8' - 8" NORTH

8

1 7

6

5

4

7

6.2

5.2

x4.1

5

A04-22A

LEVEL 02 FLOOR PLAN, AREA A 1/8" = 1'-0" 3

2

1


5

7

x9.2

6

2

1

FLOOR PLAN GENERAL NOTES

HH.4

FLOOR PLAN KEYNOTES

1. ALL PLAN DIMENSIONS TAKEN FROM FACE OF GYP BD, MASONRY OPENING OR GRIDLINE UNLESS NOTED OTHERWISE

3 A07-01

8' HIGH FIRE TREATED PLYWD BACKER BOARD - FULL WIDTH OF WALL

2

CEILING MOUNTED TRACK AND CURTAIN

3

POWER DOOR OPERATOR ACTUATOR

Ph: 303.773.0436 | Fax: 303.773.8709

3. TYPICAL PARTITION TYPE TO BE 9H, UNLESS NOTED OTHERWISE. ALL COLUMN WRAP FURRING TO BE WALL TYPE 2H, UNLESS NOTED OTHERWISE.

4

3-TIER METAL STUDENT LOCKER, TYPE ML-1

IN ASSOCIATION WITH:

4.

5

CAST GFRC COLUMN WRAP

6

PAIRED-PANEL OPERABLE PARTITION AT 27'-9" WIDE X 8'-0" HIGH

2. REFER TO CODE COMPLIANCE PLANS (A00-13 AND A00-14) FOR ALL RATED WALL LOCATIONS AND RATING REQUIREMENTS

A

AA.1

A MATCHLINE SEE 1 / A04-22C

5. FOR ALL DOORS NOT SPECIFICALLY DIMENSIONED IN PLAN PROVIDE 4" FROM ADJACENT PERPENDICULAR WALL TO HM/ALUM DOOR/WINDOW FRAME, UNLESS NOTED OTHERWISE

3 A08-40

5

33 A12-16

x14

7. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA: • CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE (SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THAN STUD WIDTH ON THE LINE. • ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED. • MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".

2002 2 A09-27

C6

ROOF BELOW

DN

8. FOR GYP BD ON MTL STUD COLUMN WRAPS NOT SPECIFICALLY DIMENSIONED IN PLAN, STUD FRAMING SHALL BE AS TIGHT TO THE COLUMN AS ALLOWED BY SPRAY-APPLIED FIREPROOFING, MEP ROUGH-IN, STRUCTURAL CONNECTIONS, ETC

C6

9.3 C10

8.5

5 OPEN TO BELOW

A07-34

C6

C14

C6

C15

x10 5 41

A07-30

x8

A10-01 11K

4' - 0"

IS31

CORRIDOR 2105

A12-11

8

CLASSROOM

2102

2013

A12-11

8

37

7' - 1 1/2 "

2013-A 1' - 9"

A12-11

7

2013-B

7' - 2"

7' - 6 1/2 "

40' - 4"

TLT

2038

2038A

-1 TB

TYP 2045-A

STOR

ELEC

2014

2040 1' - 10" F.O. STUD

DC-R-1

MB-2

1' - 0"

STAIR ST-03.2 19Q TB-1

7 A09-24

MB-3

4

MECH CHASE

2016

SP ED OFFICE

WAITING

2016

2018A

2049-A

VESTIBULE

2042A 13 A08-22

1' - 0"

STAFF DEVELOPMENT

2049-B

2042

2046

1' - 0"

4'

RC-1

" -1 1'

IS28

TB-1

2049D

2049A

TB-1

2049B

TB-1

1' - 0"

HALL 2049E

TB-1

OFFICE

OFFICE

2049C

2049B

12' - 0"

B

2049C

2048A

5' - 6 5/8 "

3' - 6 3/4 "

Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

x2 Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978 Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187 Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660 Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

1' - 0"

3 A09-22 6' - 0"

2030 4

xC

3

ROOF BELOW

A07-33

4 A07-33

2026-A

2026-B

ISSUED FOR CONSTRUCTION

xD 2 A06-13

21

2026

CORRIDOR

xE

2032

2H

2H 1' - 0"

1' - 0"

2022-B

2020

2022-A

2

A07-35

BASE BID C

7

1

1 A06-13

2024

xF

A07-33

CLASSROOM

CLASSROOM

2020

2022

8

A12-11

A12-11

A12-11

8 7

24

CLASSROOM 2024

37

4' - 0"

MEN'S TOILET 2048

2048A

LOW BOOKSHELVES, TYPICAL AT CLASSROOMS

11"

30

2046

FD

10' - 0" 2' - 0"

2048

4' - 0"

10' - 0"

WP

4' - 0"

10' - 0"

4' - 0"

10' - 0"

4' - 0"

10' - 0"

4' - 0"

10' - 0"

ITEM

#

ADD

1

DATE

DESCRIPTION

31 JAN 2014 Addendum No. 1

K

8' - 8 1/8"

xG

° 80

2' - 0" 4

1

A07-01

A07-33

28' - 0"

28' - 0"

33' - 0"

2050-A 13

4

2050

2H

33

2

1 B

A07-35

SCIENCE 9H

3

2

13

Seal: 3 4 A06-14

4 A06-14

BASE BID

13

ADD ALT #13

3 A07-35

A12-12

41

22

5

2051-A

A07-01 5' - 4"

21 13

16

PROVIDE IN-WALL BLOCKING FOR OWNER PROVIDED CHEMICAL DISPENSING SYSTEM. VERIFY EXTENT AND LOCATION WITH OWNER.

7 A09-25

TYP

IS31

16

30

CLASSROOM

K.6

2H

5 A06-12

17' - 10"

C9

DC-R2

2018

2H

M

WALL MOUNTED SOUND-ABSORPTIVE PANELS FROM +12" TO +120" AFF

9K

COW (NIC)

A12-14

23

29

E

ADD ALT #13

37

13

L

16' WIDE x 8' TALL MARKERBOARD SURFACE APPLIED TO WALL

0"

2036

8' - 8"

2049A

28

A07-31

5' - 4"

2049D

15' ALUMINUM TILT AND ROLL BLEACHER

4

A12-11

1' - 4"

OFFICE

27

1

WOMEN'S TOILET

VESTIBULE OFFICE

TEACHER DEMONSTRATION TABLE, RE: 40/A12-12

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022

6' - 0"

TB-1

26

7

IS4

JAN MB-3

LSI #6290; EXCEPT 84" HIGH

2044 1

TB-1

25

ST-01.2

2H

DISTRIBUTED MEDIA / LEARNING STREET

DATA

IS28

A07-35

4 A06-12

LSI #6290; EXCEPT 36" HIGH

D

CORRIDOR

2029

GUIDANCE

2042A

2044

24

STAIR

2021

2042

2049

LSI #6290; EXCEPT 48" HIGH

DN

8

TYP

29' - 2"

4

23

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

xA

5

A07-35 7' - 4"

22

LSI #6290; EXCEPT 60" HIGH

IS3

C9

MB-2

2018

TB-1

MB-3

3X3 SQUARE GALVANIZED STEEL BOLLARD, TYPICAL AT ALL EXTERIOR OUTSWINGING DOORS SHOWN AS THUS . RE: DETAIL 5 ON SHEET A11-17

9' - 4"

2012

3' - 3"

3H

TYP

ST-03.2

J

21

4' - 0"

4

WALL PROTECTION PADS RE: INTERIOR ELEVATIONS

10' - 0"

4' - 0"

10

CORRIDOR

2014A 2036 DC-R-1

5

2014A

ROOF ACCESS

TB-1

8' - 0"

4

8

20

x1

4' - 0"

SMALL GROUP

1

3' - 0 3/4"

10

2019-B

A12-11

-2 MB

2012-B

DN

H

6' - 6"

OPEN TO BELOW

2012-A

ASSISTANT PRINCIPAL 14

FE

12" DIAMETER CONC COLUMN RE: STRUCT.

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

19' - 10"

IS5

1' - 6"

2033

AP SEC'Y

2' - 0"

9H

2010-B

2010B

2014

5' - 0"

IS32

19

3' - 10 1/4 "

MB-2

2010B

2040

CORRIDOR

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP, SIM TO EXCEPT 30" WIDE & 60" LONG

6

CLOSET

2010A

3' - 0"

MB-2

UP

2045

2H

2025

26

2038A

6' - 6"

DISTRIBUTED MEDIA / LEARNING STREET

15

2010A

R&D

18

4' - 0"

2010-A

2038

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP

4' - 0"

20' - 4" 41' - 0 3/4"

8' - 0" 2' - 0"

2H

17

2021

18' - 6"

OH

STAIR

32

KEWAUNEE LAB TABLE ITEM #X90W364800-00_0B9 WITH EPOXY TOP

20' - 8"

C9

23 A08-22

TRENCH DRAIN RE: PLBG PLANS

TB-1

4

15

A12-11

MB-2

16

SPECIAL ED CLASSROOM

A12-11

2019-A

C9

15

WORKROOM/ PLANNING/ STORAGE

ST-02.2

MOBILE BOOKSHELVES; SEE 42/A12-17

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

bb

A12-11

CORRIDOR

OPEN TO BELOW

8' - 0" 3' - 0"

A12-14

19

15

28' - 0"

10' - 0"

7' - 1 1/2 "

2017

2010

2H

METAL SHIPS LADDER - RE; SPECIFICATIONS

Laramie | Wyoming

37

2028

33

4' - 0"

20' - 8"

2' - 0"

IS6

2 A09-24

IS33

14

10' - 0"

9"

20' - 0"

2109A

EXPOSED STL BRACED FRAME, PNT

KEWAUNEE LAB TABLE ITEM #T13W362472 WITH EPOXY TOP, SIM TO EXCEPT 90" LONG

x3

10' - 0"

2019

8

C9

ROOF BELOW

4' - 0"

37

2015

2B

3 A06-12

13

37

3H 8' - 10 3/8 "

1

ROOF BELOW

LSI #5222 18 WIDE, 84" HIGH

CLASSROOM

7' - 2"

2109A

12

10' - 0"

7' - 3 1/2 "

A12-11

19' - 1 1/2 "

18' - 11 1 /2"

MECH

WRAP COLUMNS UP TO BOTTOM CHORD OF ROOF JOISTS

NEW LARAMIE HIGH SCHOOL

ADD ALT #13

CLASSROOM

1' - 1"

2011

17' - 0"

2028

F

11

A07-30

28' - 0"

10' - 0"

KEWAUNEE #T14W364272 WORK TABLE WITH CASTERS & EPOXY TOP, SIM TO EXCEPT 48" DEEP

4' - 0"

1' - 0"

7' - 8"

2109 2B

4' - 0"

A07-30

10

2017

13' - 5"

HEAD END

3

x4

10' - 0"

6" STEEL PIPE BOLLARD, RE: CIVIL SHEET C03-04 FOR DETAILS

10' - 0"

A12-14

4' - 0"

2

2015

7

IS26

2109

2111

10' - 0"

1

9

1' - 7 3/4 "

1

ADD ALT #13

28' - 0"

CLASSROOM

EDITING

IT TECH

G

4' - 0"

A07-30

23

2"

23' - 4"

10' - 0"

A12-10

2102

3

x5

EMERGENCY EYE WASH & SHOWER; RE: PLBG

ST-01.2

2108

A12-10

18' - 1"

2

4' - 0"

8

11"

2105 TYP

2 A06-12

C

10' - 0"

BASE BID

A07-01

23

2003

E

4

CONTROL

IS35 29

ADD ALT #13

28' - 0"

2011 11K

D

4' - 0"

3H

CLASSROOM

2H

x6

10' - 0"

4 A06-13

1' - 4"

D

28' - 0"

10' - 0"

41 A11-14

3' - 0 1/8 "

BELOW AND ABOVE, TYP

10' AFF

4' - 0"

3 4 A06-13

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

PAIRED-PANEL OPERABLE PARTITION AT 27'-3" WIDE X 8'-0" HIGH

2' - 0"

11" 3' - 5"

29

DN

ST-9.2

2106

x7

10' - 0"

28' - 0 1/8 "

ST-9.2

STAIR

ADD ALT #13: 3070 HM DOOR AND FRAME W/ STORAGE ROOM HARDWARE

2003-B

11K

4' - 0"

2' - 0"

2106

27' - 9"

SOUND

IS36

2003-A

MEDIA LAB

10' - 0"

2108 E

28' - 0"

C6

11K

ADD ALTERNATE No. 12: ADD SECOND FLOOR CONC ON MTL DECK AND STRUCTURAL STEEL

xBB

2' - 4 7/8 "

2H

27' - 3"

SEE 1 / A04-22D

MATCHLINE

xAA

23' - 4"

16

CORRIDOR 2037

16 26 8

2051-B

2051A-B

P

FH-2

A10-01

6

8' - 8" 5' - 4"

F

D

C

6' - 0"

B

A

8

2052

LBA Project Date

N.2 25 A11-14

FE

A

42

2012.32 15 JANUARY 2014

LEVEL 02 FLOOR PLAN - AREA B

32

TYP AT L2 41 OH

20

A12-12

23

MATCHLINE

16

NORTH

SEE 1 / A04-22A

IS31

34' - 8"

9.3

2050A-B

16

A12-12

E

31

24

2051A

FE

FE

2050A

26

MB-1

2051A-A

TB-1

PREP

SEE 1 / A04-22A

7

BUILDING EXP JT

FH-1

9' - 4 3/4"

MATCHLINE

PREP A12-12

G

N

5' - 4"

FE

N.5

TB-1

FH-2

25 A11-14

A

19

5 A06-14

8' - 8"

2051

37 A11-14

5' - 4"

9' - 0"

SCIENCE

FE

2050A-A

32

16

Key Plan:

FD

MB-1

IS31

8

FH-1 DC-R-3 DC-R-3 DC-R-3

41 O.H.

2050-B

3' - 0" 3' - 0" 3' - 0"

A12-12

26

1' - 0"

38' - 0"

34

23

13

1' - 8" 5' - 0 3/8"

16

12' - 0"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

9.5

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

7

11' - 4"

x

6. ALL INTERIOR CMU PARTITIONS SHALL EXTEND TO UNDERSIDE OF FLOOR/ROOF DECK ABOVE AND BE BRACED AS PER STURTURAL DRAWINGS, UNLESS NOTED OTHERWISE

3 A06-10

A07-20

CORRIDOR

B

SEE A00-12 FOR MOUNTING HEIGHTS AND WALL MOUNTED DISPLAY BOARDS

7' - 4"

F

Lantz-Boggio Architects, P.C.

1

10' - 0"

8

3

28' - 0"

11.6

4

27' - 6"

6

1' - 9"

7

12' - 0"

34' - 8"

7

8 5

5.2

1 4

A04-22B

LEVEL 02 FLOOR PLAN, AREA 2 1/8" = 1'-0" 3

2

1


7

6

5

4

3

2

1

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEYNOTES

1. ALL PLAN DIMENSIONS TAKEN FROM FACE OF GYP BD, MASONRY OPENING OR GRIDLINE UNLESS NOTED OTHERWISE

1

8' HIGH FIRE TREATED PLYWD BACKER BOARD - FULL WIDTH OF WALL

2

CEILING MOUNTED TRACK AND CURTAIN

3

POWER DOOR OPERATOR ACTUATOR

Lantz-Boggio Architects, P.C.

3. TYPICAL PARTITION TYPE TO BE 9H, UNLESS NOTED OTHERWISE. ALL COLUMN WRAP FURRING TO BE WALL TYPE 2H, UNLESS NOTED OTHERWISE.

4

3-TIER METAL STUDENT LOCKER, TYPE ML-1

Ph: 303.773.0436 | Fax: 303.773.8709

4.

5

CAST GFRC COLUMN WRAP

6

PAIRED-PANEL OPERABLE PARTITION AT 27'-9" WIDE X 8'-0" HIGH

IN ASSOCIATION WITH:

7

PAIRED-PANEL OPERABLE PARTITION AT 27'-3" WIDE X 8'-0" HIGH

8

EMERGENCY EYE WASH & SHOWER; RE: PLBG

9

6" STEEL PIPE BOLLARD, RE: CIVIL SHEET C03-04 FOR DETAILS

10

KEWAUNEE #T14W364272 WORK TABLE WITH CASTERS & EPOXY TOP, SIM TO EXCEPT 48" DEEP

11

WRAP COLUMNS UP TO BOTTOM CHORD OF ROOF JOISTS

12

LSI #5222 18 WIDE, 84" HIGH

13

KEWAUNEE LAB TABLE ITEM #T13W362472 WITH EPOXY TOP, SIM TO EXCEPT 90" LONG

14

METAL SHIPS LADDER - RE; SPECIFICATIONS

15

MOBILE BOOKSHELVES; SEE 42/A12-17

16

KEWAUNEE LAB TABLE ITEM #X90W364800-00_0B9 WITH EPOXY TOP

17

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP

18

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP, SIM TO EXCEPT 30" WIDE & 60" LONG

19

12" DIAMETER CONC COLUMN RE: STRUCT.

20

WALL PROTECTION PADS RE: INTERIOR ELEVATIONS

21

3X3 SQUARE GALVANIZED STEEL BOLLARD, TYPICAL AT ALL EXTERIOR OUTSWINGING DOORS SHOWN AS THUS . RE: DETAIL 5 ON SHEET A11-17

22

LSI #6290; EXCEPT 60" HIGH

23

LSI #6290; EXCEPT 48" HIGH

24

LSI #6290; EXCEPT 36" HIGH

25

LSI #6290; EXCEPT 84" HIGH

26

TEACHER DEMONSTRATION TABLE, RE: 40/A12-12

27

15' ALUMINUM TILT AND ROLL BLEACHER

28

16' WIDE x 8' TALL MARKERBOARD SURFACE APPLIED TO WALL

29

WALL MOUNTED SOUND-ABSORPTIVE PANELS FROM +12" TO +120" AFF

30

PROVIDE IN-WALL BLOCKING FOR OWNER PROVIDED CHEMICAL DISPENSING SYSTEM. VERIFY EXTENT AND LOCATION WITH OWNER.

2. REFER TO CODE COMPLIANCE PLANS (A00-13 AND A00-14) FOR ALL RATED WALL LOCATIONS AND RATING REQUIREMENTS

SEE A00-12 FOR MOUNTING HEIGHTS AND WALL MOUNTED DISPLAY BOARDS

5. FOR ALL DOORS NOT SPECIFICALLY DIMENSIONED IN PLAN PROVIDE 4" FROM ADJACENT PERPENDICULAR WALL TO HM/ALUM DOOR/WINDOW FRAME, UNLESS NOTED OTHERWISE 6. ALL INTERIOR CMU PARTITIONS SHALL EXTEND TO UNDERSIDE OF FLOOR/ROOF DECK ABOVE AND BE BRACED AS PER STURTURAL DRAWINGS, UNLESS NOTED OTHERWISE

F

11.6

11

10

13' - 0"

9

20' - 0"

8

29' - 4"

28' - 4"

7. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA: • CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE (SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THAN STUD WIDTH ON THE LINE. • ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED. • MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".

6.3

8. FOR GYP BD ON MTL STUD COLUMN WRAPS NOT SPECIFICALLY DIMENSIONED IN PLAN, STUD FRAMING SHALL BE AS TIGHT TO THE COLUMN AS ALLOWED BY SPRAY-APPLIED FIREPROOFING, MEP ROUGH-IN, STRUCTURAL CONNECTIONS, ETC

12' - 0" 2 A07-21

2 A06-10

1

x9

A07-21

OPEN TO BELOW EXTERIOR MECHANICAL BELOW

xEE

E

16

4

3

A10-11

A07-21

A07-21

48' - 10"

NEW LARAMIE HIGH SCHOOL Laramie | Wyoming Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408 Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775 Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

E

OPEN TO BELOW

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

5

26' - 0"

A07-21

OPEN TO BELOW

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

EXTERIOR MECHANICAL WELL BELOW

MM.9

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

6' - 8"

SEE 1 / A04-22E

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

PP

MATCHLINE

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

MM D

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

MATCHLINE

SEE 1 / A04-22D

29' - 0"

D

OPEN TO BELOW OPEN TO BELOW

KK

ISSUED FOR CONSTRUCTION

x9.3

x9.2

24' - 0"

1 A09-25

C20

HH.3

HH.3

STAIR DN

ST-07.2

HH 25

19H

TYP

23

22

TYP TYP

22

22

15

REFER TO 'TH' SERIES DRAWINGS

ROOF BELOW

2100-B

24

24' - 0"

25

4 A10-09

C21

2100

TOP

ITEM

#

DATE

DESCRIPTION

22

TYP

MEDIA CENTER CONFERENCE/ CLASSROOM

C

6' - 8"

ST-07.2A

C

C11

15

C19

FF

22 15

8 24' - 0"

AV STOR

22

2103

2' - 0"

15 24

TYP

2103

CORRIDOR

1 A06-10

15

2001 B

A12-15

37 A12-14

9

STAND UP COMPUTER TABLE

B

C18

DD

C12

OFFICE/ WORKROOM

Seal:

2101 15

15

24

24' - 0"

3 A07-20 TYP

22

2100-A

Key Plan:

A

A

A

A

2H

C22

C13

C17

TOP

DN

AA.1

2123

2121

2125

5"

2120

9"

2121

11K

A

3 A08-40

2' - 8"

8' - 0"

8' - 0"

3' - 4"

AA.1 C14

A

C16

A 3 A06-10

3 A08-40

1

1/8" = 1'-0" 6

1

6

7

HH.4

A04-22C

LEVEL 02 FLOOR PLAN, AREA C 1/8" = 1'-0" 5

LEVEL 02 FLOOR PLAN - AREA C

A07-20

8

THEATER BALCONY LEVEL

2012.32 15 JANUARY 2014

NORTH

2002

A07-01

7

2104

CORRIDOR

1

2

LBA Project Date

1' - 0"

2123

2125

2127

11K

80' - 3 5/8"

TYP

CONFERENCE IS20

11K A

D

A

25' - 0"

WOMEN'S TOILET

24

2104 7' - 2"

MEN'S TOILET

VEST

F

B

7' - 8"

A

2124

ST-15.B

11K

AA.1

2124

2127

JC

2120

VEST

11 A09-10

EL-02

STORAGE

E

ELEVATOR

DN

40 A08-22

5"

DN

11' - 4"

UP

G

C

BB

DN

ST-14.B

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

4 A06-10

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

4

3

2

1


7

6

5

4

3

2

1

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEYNOTES

1. ALL PLAN DIMENSIONS TAKEN FROM FACE OF GYP BD, MASONRY OPENING OR GRIDLINE UNLESS NOTED OTHERWISE

1

8' HIGH FIRE TREATED PLYWD BACKER BOARD - FULL WIDTH OF WALL

2

CEILING MOUNTED TRACK AND CURTAIN

3

POWER DOOR OPERATOR ACTUATOR

3. TYPICAL PARTITION TYPE TO BE 9H, UNLESS NOTED OTHERWISE. ALL COLUMN WRAP FURRING TO BE WALL TYPE 2H, UNLESS NOTED OTHERWISE.

4

3-TIER METAL STUDENT LOCKER, TYPE ML-1

4.

5

CAST GFRC COLUMN WRAP

6

PAIRED-PANEL OPERABLE PARTITION AT 27'-9" WIDE X 8'-0" HIGH

7

PAIRED-PANEL OPERABLE PARTITION AT 27'-3" WIDE X 8'-0" HIGH

8

EMERGENCY EYE WASH & SHOWER; RE: PLBG

2. REFER TO CODE COMPLIANCE PLANS (A00-13 AND A00-14) FOR ALL RATED WALL LOCATIONS AND RATING REQUIREMENTS

SEE A00-12 FOR MOUNTING HEIGHTS AND WALL MOUNTED DISPLAY BOARDS

5. FOR ALL DOORS NOT SPECIFICALLY DIMENSIONED IN PLAN PROVIDE 4" FROM ADJACENT PERPENDICULAR WALL TO HM/ALUM DOOR/WINDOW FRAME, UNLESS NOTED OTHERWISE 6. ALL INTERIOR CMU PARTITIONS SHALL EXTEND TO UNDERSIDE OF FLOOR/ROOF DECK ABOVE AND BE BRACED AS PER STURTURAL DRAWINGS, UNLESS NOTED OTHERWISE

F

11

WRAP COLUMNS UP TO BOTTOM CHORD OF ROOF JOISTS

12

LSI #5222 18 WIDE, 84" HIGH

13

KEWAUNEE LAB TABLE ITEM #T13W362472 WITH EPOXY TOP, SIM TO EXCEPT 90" LONG

NEW LARAMIE HIGH SCHOOL

14

METAL SHIPS LADDER - RE; SPECIFICATIONS

Laramie | Wyoming

15

MOBILE BOOKSHELVES; SEE 42/A12-17

16

KEWAUNEE LAB TABLE ITEM #X90W364800-00_0B9 WITH EPOXY TOP

17

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP

18

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP, SIM TO EXCEPT 30" WIDE & 60" LONG

19

12" DIAMETER CONC COLUMN RE: STRUCT.

20

WALL PROTECTION PADS RE: INTERIOR ELEVATIONS

21

3X3 SQUARE GALVANIZED STEEL BOLLARD, TYPICAL AT ALL EXTERIOR OUTSWINGING DOORS SHOWN AS THUS . RE: DETAIL 5 ON SHEET A11-17

22

LSI #6290; EXCEPT 60" HIGH

23

LSI #6290; EXCEPT 48" HIGH

24

LSI #6290; EXCEPT 36" HIGH

25

LSI #6290; EXCEPT 84" HIGH

26

TEACHER DEMONSTRATION TABLE, RE: 40/A12-12

27

15' ALUMINUM TILT AND ROLL BLEACHER

28

16' WIDE x 8' TALL MARKERBOARD SURFACE APPLIED TO WALL

7

29

WALL MOUNTED SOUND-ABSORPTIVE PANELS FROM +12" TO +120" AFF

A07-11

30

PROVIDE IN-WALL BLOCKING FOR OWNER PROVIDED CHEMICAL DISPENSING SYSTEM. VERIFY EXTENT AND LOCATION WITH OWNER.

SEE 1 / A04-22C

MATCHLINE

SEE 1 / A04-22F

MATCHLINE

11.6

8H

CHASE

CHASE

8H

8H 54D

JJ.7

54D

E

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

KEWAUNEE #T14W364272 WORK TABLE WITH CASTERS & EPOXY TOP, SIM TO EXCEPT 48" DEEP

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408 Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775 Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

E

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094 Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

GG.3

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187 Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

OPEN TO BELOW D

D

18

A08-14

42

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

EE

EAST MECHANICAL ROOM

41

2197

17

ISSUED FOR CONSTRUCTION BB.5 40 A10-01 C

C 8H UTILITY CHASE

UTILITY CHASE CJ 6' - 4"

CJ 20' - 8"

2' - 8"

20' - 8"

IS38

IS38

CJ

2' - 8"

20' - 8"

2' - 8"

20' - 8"

IS38

STUDENT SEATING

6' - 4 1/8"

IS38

ITEM

#

DATE

DESCRIPTION

6' - 8"

4' - 4"

ALIGN

4' - 8"

2' - 8"

AA.1 A

2197

3' - 0 1/4"

A

2' - 8"

2193-A

3' - 4"

2002B

4' - 8"

2' - 0"

12' - 4 3/8"

11K 7 A10-01

CORRIDOR

37 A10-01

2002 41 A10-01

B

x GA TYP

3x3 VIDEO WALL RE: A/V DWGS

3 A07-12

xBB B

B

Seal: 41' - 8"

GA

xAA xA 8 A09-24

OPEN TO BELOW

Key Plan: G

E

F

D

C ST-9.2

C.8 STAIR

B

ST-9.2 12' - 0"

A MATCHL INE SEE 1 / A04-22 B

D.5

SEE 1 / A04-22F

D MATCHLINE

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

8H

IN ASSOCIATION WITH:

10

13.1 12.9

A07-02

Ph: 303.773.0436 | Fax: 303.773.8709

6" STEEL PIPE BOLLARD, RE: CIVIL SHEET C03-04 FOR DETAILS

8. FOR GYP BD ON MTL STUD COLUMN WRAPS NOT SPECIFICALLY DIMENSIONED IN PLAN, STUD FRAMING SHALL BE AS TIGHT TO THE COLUMN AS ALLOWED BY SPRAY-APPLIED FIREPROOFING, MEP ROUGH-IN, STRUCTURAL CONNECTIONS, ETC

16

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

9

7. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA: • CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE (SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THAN STUD WIDTH ON THE LINE. • ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED. • MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".

2

Lantz-Boggio Architects, P.C.

LBA Project Date

A

A

15.9

15

14.2

2012.32 15 JANUARY 2014

LEVEL 02 FLOOR PLAN - AREA D

13 NORTH

1 7

6

A04-22D

LEVEL 02 FLOOR PLAN, AREA D 1/8" = 1'-0" 5

4

3

2

1


7

6

5

4

3

2

1

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEYNOTES

1. ALL PLAN DIMENSIONS TAKEN FROM FACE OF GYP BD, MASONRY OPENING OR GRIDLINE UNLESS NOTED OTHERWISE

1

8' HIGH FIRE TREATED PLYWD BACKER BOARD - FULL WIDTH OF WALL

2

CEILING MOUNTED TRACK AND CURTAIN

3

POWER DOOR OPERATOR ACTUATOR

3. TYPICAL PARTITION TYPE TO BE 9H, UNLESS NOTED OTHERWISE. ALL COLUMN WRAP FURRING TO BE WALL TYPE 2H, UNLESS NOTED OTHERWISE.

4

3-TIER METAL STUDENT LOCKER, TYPE ML-1

4.

5

CAST GFRC COLUMN WRAP

6

PAIRED-PANEL OPERABLE PARTITION AT 27'-9" WIDE X 8'-0" HIGH

7

PAIRED-PANEL OPERABLE PARTITION AT 27'-3" WIDE X 8'-0" HIGH

2. REFER TO CODE COMPLIANCE PLANS (A00-13 AND A00-14) FOR ALL RATED WALL LOCATIONS AND RATING REQUIREMENTS

SEE A00-12 FOR MOUNTING HEIGHTS AND WALL MOUNTED DISPLAY BOARDS

5. FOR ALL DOORS NOT SPECIFICALLY DIMENSIONED IN PLAN PROVIDE 4" FROM ADJACENT PERPENDICULAR WALL TO HM/ALUM DOOR/WINDOW FRAME, UNLESS NOTED OTHERWISE 6. ALL INTERIOR CMU PARTITIONS SHALL EXTEND TO UNDERSIDE OF FLOOR/ROOF DECK ABOVE AND BE BRACED AS PER STURTURAL DRAWINGS, UNLESS NOTED OTHERWISE

F

7. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA: • CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE (SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THAN STUD WIDTH ON THE LINE. • ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED. • MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".

E

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111 Ph: 303.773.0436 | Fax: 303.773.8709 IN ASSOCIATION WITH:

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

8

EMERGENCY EYE WASH & SHOWER; RE: PLBG

9

6" STEEL PIPE BOLLARD, RE: CIVIL SHEET C03-04 FOR DETAILS

10

KEWAUNEE #T14W364272 WORK TABLE WITH CASTERS & EPOXY TOP, SIM TO EXCEPT 48" DEEP

11

WRAP COLUMNS UP TO BOTTOM CHORD OF ROOF JOISTS

12

LSI #5222 18 WIDE, 84" HIGH

13

KEWAUNEE LAB TABLE ITEM #T13W362472 WITH EPOXY TOP, SIM TO EXCEPT 90" LONG

14

METAL SHIPS LADDER - RE; SPECIFICATIONS

15

MOBILE BOOKSHELVES; SEE 42/A12-17

16

KEWAUNEE LAB TABLE ITEM #X90W364800-00_0B9 WITH EPOXY TOP

17

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP

18

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP, SIM TO EXCEPT 30" WIDE & 60" LONG

19

12" DIAMETER CONC COLUMN RE: STRUCT.

20

WALL PROTECTION PADS RE: INTERIOR ELEVATIONS

21

3X3 SQUARE GALVANIZED STEEL BOLLARD, TYPICAL AT ALL EXTERIOR OUTSWINGING DOORS SHOWN AS THUS . RE: DETAIL 5 ON SHEET A11-17

22

LSI #6290; EXCEPT 60" HIGH

23

LSI #6290; EXCEPT 48" HIGH

24

LSI #6290; EXCEPT 36" HIGH

25

LSI #6290; EXCEPT 84" HIGH

26

TEACHER DEMONSTRATION TABLE, RE: 40/A12-12

27

15' ALUMINUM TILT AND ROLL BLEACHER

28

16' WIDE x 8' TALL MARKERBOARD SURFACE APPLIED TO WALL

29

WALL MOUNTED SOUND-ABSORPTIVE PANELS FROM +12" TO +120" AFF

30

PROVIDE IN-WALL BLOCKING FOR OWNER PROVIDED CHEMICAL DISPENSING SYSTEM. VERIFY EXTENT AND LOCATION WITH OWNER.

NEW LARAMIE HIGH SCHOOL Laramie | Wyoming Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408 Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775 Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

E

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094 Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

16.4

16

15.5

13.6

2

13.1 12.9

11.6

11

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

A07-02 1 A06-11

4 A07-10

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

4 A06-10

WW 13' - 0" 3 D

D

A07-10

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

UU 13' - 2"

UU

C54

TT

53' - 10"

ISSUED FOR CONSTRUCTION

C

C

39 2 A06-11 13

A08-14

37

MATCHLINE

15

SEE 1 / A04-22C

SEE 1 / A04-22F

MATCHLINE

ITEM

#

DATE

DESCRIPTION

PP

1 A07-16

26' - 0"

OPEN TO BELOW

27 A10-11

2 A07-10

B

B

Seal:

MM.9 6' - 8"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

8. FOR GYP BD ON MTL STUD COLUMN WRAPS NOT SPECIFICALLY DIMENSIONED IN PLAN, STUD FRAMING SHALL BE AS TIGHT TO THE COLUMN AS ALLOWED BY SPRAY-APPLIED FIREPROOFING, MEP ROUGH-IN, STRUCTURAL CONNECTIONS, ETC

Lantz-Boggio Architects, P.C.

MM

1 A07-10 ROOF BELOW

LL

Key Plan:

54D

G

E

F

D

C CHASE CHASE B

MATCHLINE SEE 1 / A04-22D 54D

A

LBA Project Date

2012.32 15 JANUARY 2014

2 A07-02 A

A

LEVEL 02 FLOOR PLAN - AREA E

NORTH

1 7

6

5

A04-22E

LEVEL 02 FLOOR PLAN, AREA E 1/8" = 1'-0" 4

3

2

1


7

6

5

4

3

2

1

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEYNOTES

1. ALL PLAN DIMENSIONS TAKEN FROM FACE OF GYP BD, MASONRY OPENING OR GRIDLINE UNLESS NOTED OTHERWISE

1

8' HIGH FIRE TREATED PLYWD BACKER BOARD - FULL WIDTH OF WALL

2

CEILING MOUNTED TRACK AND CURTAIN

3

POWER DOOR OPERATOR ACTUATOR

3. TYPICAL PARTITION TYPE TO BE 9H, UNLESS NOTED OTHERWISE. ALL COLUMN WRAP FURRING TO BE WALL TYPE 2H, UNLESS NOTED OTHERWISE.

4

3-TIER METAL STUDENT LOCKER, TYPE ML-1

4.

5

CAST GFRC COLUMN WRAP

Ph: 303.773.0436 | Fax: 303.773.8709

6

PAIRED-PANEL OPERABLE PARTITION AT 27'-9" WIDE X 8'-0" HIGH

IN ASSOCIATION WITH:

7

PAIRED-PANEL OPERABLE PARTITION AT 27'-3" WIDE X 8'-0" HIGH

8

EMERGENCY EYE WASH & SHOWER; RE: PLBG

2. REFER TO CODE COMPLIANCE PLANS (A00-13 AND A00-14) FOR ALL RATED WALL LOCATIONS AND RATING REQUIREMENTS

SEE A00-12 FOR MOUNTING HEIGHTS AND WALL MOUNTED DISPLAY BOARDS

5. FOR ALL DOORS NOT SPECIFICALLY DIMENSIONED IN PLAN PROVIDE 4" FROM ADJACENT PERPENDICULAR WALL TO HM/ALUM DOOR/WINDOW FRAME, UNLESS NOTED OTHERWISE

22

17.2

16.4

16

6. ALL INTERIOR CMU PARTITIONS SHALL EXTEND TO UNDERSIDE OF FLOOR/ROOF DECK ABOVE AND BE BRACED AS PER STURTURAL DRAWINGS, UNLESS NOTED OTHERWISE

F

7. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA: • CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE (SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THAN STUD WIDTH ON THE LINE. • ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED. • MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".

1 A07-02

IS40

3' - 0"

A07-13 WALL-MOUNTED HANDRAIL TYPE 'WH'

IS39

LL.5

21' - 8"

2' - 0"

1' - 0"

LL

40C 33' - 4"

4" CMU VENEER

21' - 0" TYP

6" STEEL PIPE BOLLARD, RE: CIVIL SHEET C03-04 FOR DETAILS

10

KEWAUNEE #T14W364272 WORK TABLE WITH CASTERS & EPOXY TOP, SIM TO EXCEPT 48" DEEP

11

WRAP COLUMNS UP TO BOTTOM CHORD OF ROOF JOISTS

12

LSI #5222 18 WIDE, 84" HIGH

13

KEWAUNEE LAB TABLE ITEM #T13W362472 WITH EPOXY TOP, SIM TO EXCEPT 90" LONG

14

METAL SHIPS LADDER - RE; SPECIFICATIONS

15

MOBILE BOOKSHELVES; SEE 42/A12-17

16

KEWAUNEE LAB TABLE ITEM #X90W364800-00_0B9 WITH EPOXY TOP

17

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP

18

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP, SIM TO EXCEPT 30" WIDE & 60" LONG

19

12" DIAMETER CONC COLUMN RE: STRUCT.

20

WALL PROTECTION PADS RE: INTERIOR ELEVATIONS

21

3X3 SQUARE GALVANIZED STEEL BOLLARD, TYPICAL AT ALL EXTERIOR OUTSWINGING DOORS SHOWN AS THUS . RE: DETAIL 5 ON SHEET A11-17

22

LSI #6290; EXCEPT 60" HIGH

23

LSI #6290; EXCEPT 48" HIGH

24

LSI #6290; EXCEPT 36" HIGH

25

LSI #6290; EXCEPT 84" HIGH

26

TEACHER DEMONSTRATION TABLE, RE: 40/A12-12

27

15' ALUMINUM TILT AND ROLL BLEACHER

28

16' WIDE x 8' TALL MARKERBOARD SURFACE APPLIED TO WALL

29

WALL MOUNTED SOUND-ABSORPTIVE PANELS FROM +12" TO +120" AFF

30

PROVIDE IN-WALL BLOCKING FOR OWNER PROVIDED CHEMICAL DISPENSING SYSTEM. VERIFY EXTENT AND LOCATION WITH OWNER.

NEW LARAMIE HIGH SCHOOL Laramie | Wyoming Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408 Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775 Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

E

12' - 0"

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

WEST MECHANICAL ROOM

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

4' - 6"

GG

13

4

40

A07-13

A08-15

2

37

A07-12

D

D

4' - 0"

OPEN TO BELOW

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

DC-S-1

12' - 0"

16

8' - 0"

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

2194

WALL MOUNTED POOL SCOREBOARD

36' - 4"

9

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

DC-S-1

8' - 0"

JJ

7' - 4"

5 A06-11

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

SEE 1 / A04-22D

MATCHLINE

DC-S-1

4' - 6" TYP

12' - 0"

E

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

3 A07-13

6' - 6"

EE.2 POOL BLEACHERS

14' - 0"

2195 2193-B 1

SET FRAME AND DOOR ON 6" CONC CURB

DC-S-1

12' - 0"

A07-12

2

3H F.V.

A07-13

6' - 3"

36' - 4"

ISSUED FOR CONSTRUCTION

9K

8' - 0"

12' - 0"

INTERMEDIATE HANDRAIL TYPE GD-i, TYPICAL

GLASS GUARDRAIL WITH ALUMINUM CAP, TYPICAL

C

STORAGE

DC-S-1

C

UPPER SEATING 121'-0"

LOWER SEATING 111'-0"

CC

2193

#

DATE

DESCRIPTION

6' - 0"

ITEM

GLASS GUARDRAIL WITH ALUMINUM CAP

AA

20' - 4"

54D-GF CJ

A

CJ

CJ

CJ

CJ

CJ 2195-C

CJ

A 6' - 8"

4' - 4"

DOWN TO LEVEL 111'-0"

20' - 4"

114'-8"

1 121'-0"

111'-0"

A07-15

B

2193-A

WALL-MOUNTED HANDRAIL TYPE 'WH'

2195-B

B

B

Seal:

GFRG-1 COLUMN COVER, TYP DOWN TO LEVEL 114'-8"

4 A06-11

2

OPEN TO BELOW

A07-15

2 A04-22F

C

18

6 A09-28

17.2

17

OPEN TO BELOW

Key Plan:

A

3 EDGE OF LANDING 121'-0" ABOVE

C.5

2

E

F

D

UP TO LEVEL 114'-8" B

111'-0"

A07-14

G

C

A07-15

1 A07-14

B

A

1

C.8 1 A06-12

A

17.9

LBA Project Date

DOWN TO LEVEL 100'-0"

17

SEE 1 / A04-22D

A07-02

MATCHLINE

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

1

MM.6

2195-A

NN

8. FOR GYP BD ON MTL STUD COLUMN WRAPS NOT SPECIFICALLY DIMENSIONED IN PLAN, STUD FRAMING SHALL BE AS TIGHT TO THE COLUMN AS ALLOWED BY SPRAY-APPLIED FIREPROOFING, MEP ROUGH-IN, STRUCTURAL CONNECTIONS, ETC

SEE 1 / A04-22E

MATCHLINE

UP

Lantz-Boggio Architects, P.C.

A

2012.32 15 JANUARY 2014

LEVEL 02 FLOOR PLAN - AREA F

15.9 NORTH

17.9

1 7

LEVEL 02 FLOOR PLAN, AREA F

2

1/8" = 1'-0" 6

5

4

3

A04-22F

LANDING AT LEVEL 111'-0" 1/8" = 1'-0" 2

1


7

6

5

4

3

2

1

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEYNOTES

1. ALL PLAN DIMENSIONS TAKEN FROM FACE OF GYP BD, MASONRY OPENING OR GRIDLINE UNLESS NOTED OTHERWISE

1

8' HIGH FIRE TREATED PLYWD BACKER BOARD - FULL WIDTH OF WALL

2

CEILING MOUNTED TRACK AND CURTAIN

3

POWER DOOR OPERATOR ACTUATOR

3. TYPICAL PARTITION TYPE TO BE 9H, UNLESS NOTED OTHERWISE. ALL COLUMN WRAP FURRING TO BE WALL TYPE 2H, UNLESS NOTED OTHERWISE.

4

3-TIER METAL STUDENT LOCKER, TYPE ML-1

4.

5

CAST GFRC COLUMN WRAP

6

PAIRED-PANEL OPERABLE PARTITION AT 27'-9" WIDE X 8'-0" HIGH

7

PAIRED-PANEL OPERABLE PARTITION AT 27'-3" WIDE X 8'-0" HIGH

2. REFER TO CODE COMPLIANCE PLANS (A00-13 AND A00-14) FOR ALL RATED WALL LOCATIONS AND RATING REQUIREMENTS

SEE A00-12 FOR MOUNTING HEIGHTS AND WALL MOUNTED DISPLAY BOARDS

5. FOR ALL DOORS NOT SPECIFICALLY DIMENSIONED IN PLAN PROVIDE 4" FROM ADJACENT PERPENDICULAR WALL TO HM/ALUM DOOR/WINDOW FRAME, UNLESS NOTED OTHERWISE 6. ALL INTERIOR CMU PARTITIONS SHALL EXTEND TO UNDERSIDE OF FLOOR/ROOF DECK ABOVE AND BE BRACED AS PER STURTURAL DRAWINGS, UNLESS NOTED OTHERWISE

F

IN ASSOCIATION WITH:

6" STEEL PIPE BOLLARD, RE: CIVIL SHEET C03-04 FOR DETAILS

10

KEWAUNEE #T14W364272 WORK TABLE WITH CASTERS & EPOXY TOP, SIM TO EXCEPT 48" DEEP

11

WRAP COLUMNS UP TO BOTTOM CHORD OF ROOF JOISTS

12

LSI #5222 18 WIDE, 84" HIGH

13

KEWAUNEE LAB TABLE ITEM #T13W362472 WITH EPOXY TOP, SIM TO EXCEPT 90" LONG

14

METAL SHIPS LADDER - RE; SPECIFICATIONS

15

MOBILE BOOKSHELVES; SEE 42/A12-17

16

KEWAUNEE LAB TABLE ITEM #X90W364800-00_0B9 WITH EPOXY TOP

17

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP

18

KEWAUNEE LAB TABLE ITEM #T14W364272 WITH EPOXY TOP, SIM TO EXCEPT 30" WIDE & 60" LONG

19

12" DIAMETER CONC COLUMN RE: STRUCT.

20

WALL PROTECTION PADS RE: INTERIOR ELEVATIONS

21

3X3 SQUARE GALVANIZED STEEL BOLLARD, TYPICAL AT ALL EXTERIOR OUTSWINGING DOORS SHOWN AS THUS . RE: DETAIL 5 ON SHEET A11-17

22

LSI #6290; EXCEPT 60" HIGH

23

LSI #6290; EXCEPT 48" HIGH

24

LSI #6290; EXCEPT 36" HIGH

25

LSI #6290; EXCEPT 84" HIGH

26

TEACHER DEMONSTRATION TABLE, RE: 40/A12-12

STEEL BEARING PLATE RE: STRUCTURAL

27

15' ALUMINUM TILT AND ROLL BLEACHER

28

16' WIDE x 8' TALL MARKERBOARD SURFACE APPLIED TO WALL

SEALANT W/ BACKER ROD

29

WALL MOUNTED SOUND-ABSORPTIVE PANELS FROM +12" TO +120" AFF

30

PROVIDE IN-WALL BLOCKING FOR OWNER PROVIDED CHEMICAL DISPENSING SYSTEM. VERIFY EXTENT AND LOCATION WITH OWNER.

L2 FFE 121' - 0"

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

9

8" CMU TO UNDERSIDE OF ROOF DECK ABOVE

NEW LARAMIE HIGH SCHOOL Laramie | Wyoming Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408 Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775 Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

E

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

CMU FACE SHELL TO CONCEAL SLAB EDGE

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

8" CMU CUT TO FOLLOW CONTOUR OF PRECAST STADIUM SEATING

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187 Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

WALL DETAIL @ POOL

2

D

22

1 1/2" = 1'-0"

D

18

1 A06-11

17.2

16.4

ISSUED FOR CONSTRUCTION

1

A07-02

A07-11

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

16

1 2

A07-11

UU C

C

ITEM

#

DATE

DESCRIPTION

ROOF BELOW

35 A11-16

5 A06-11

3

4

A07-11

A07-11

5 A09-26

RR 5' - 11 5/8"

10' - 0"

20' - 0"

10' - 0"

STAIR

B

6

ST-13.2

B

Seal:

A07-11

W10 ST-13.2

W3

2196

STORAGE 2196A

54C

20

2199 4' - 6" +121'-0"

WRESTLING 2188

ELEVATOR 114'-8"

12' - 8 3/4"

20

TB-1

52C

20

2' - 9"

3' - 4" 2190

52C

EWC

STORAGE

16' - 7"

A07-11

2188A

2188A 20

8

4' - 7 1/4" 2' - 6"

A

WH

LOBBY

STAIR

2199

ST-14.2

COPIER / PRINTER NIC

POOL CONTROL ROOM

IS40

2190

OPEN-GRATE STEEL STAIR W/ HDRL BOTH SIDES

Key Plan:

WEST MECHANICAL ROOM

28

40C

A12-15

IS39

121'-0"

12' - 0"

20

NN

EL-03

UP

2188

52C 5

EL-03.2

GC

+114'-8"

2194

9K 2 2' - 8"

ROOF HATCH ABOVE

A12-11

A04-22G

F.V. 52C

7

5

2' - 0"

MB-3

EL-03.3

UP

52C

LOW

LBA Project Date

IS41

2195-A

2' - 2"

3' - 3"

2 A09-26

20' - 0"

7' - 0"

62C

5' - 6 3/4"

10' - 0"

ST-12.2

2' - 3 3/8"

STAIR

CORRIDOR

2196A

OPEN TO BELOW

(10) EQ TREADS

QQ ST-12.2

W6

WRESTLING MAT (NIC)

20

64C

4' - 0"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

Ph: 303.773.0436 | Fax: 303.773.8709

EMERGENCY EYE WASH & SHOWER; RE: PLBG

8. FOR GYP BD ON MTL STUD COLUMN WRAPS NOT SPECIFICALLY DIMENSIONED IN PLAN, STUD FRAMING SHALL BE AS TIGHT TO THE COLUMN AS ALLOWED BY SPRAY-APPLIED FIREPROOFING, MEP ROUGH-IN, STRUCTURAL CONNECTIONS, ETC

E

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

8

7. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA: • CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE (SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THAN STUD WIDTH ON THE LINE. • ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED. • MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".

Lantz-Boggio Architects, P.C.

14

A 2' - 0 1/2"

28' - 7 1/4"

4' - 9"

2

7

6

5

A04-22G

LEVEL 02 FLOOR PLAN, AREA G - ENHANCED 1/8" = 1'-0" 4

LEVEL 02 FLOOR PLAN, AREA G

NORTH

A07-16

1

2012.32 15 JANUARY 2014

3

2

1


7

6

5

4

3

2

1

12' - 6" 3' - 0"

3' - 0"

LSI #3002 CABINET DEPTH 14 1/4

LSI #3002 CABINET DEPTH 14 1/4

2' - 6"

GENERAL NOTES

4' - 0"

LSI #3002 CABINET DEPTH 14 1/4

1. VERIFY MOUNTING HEIGHTS AND CLEARANCES AT ALL LOCATIONS; NOTIFY THE ARCHITECT OF ANY DISCREPANCIES WITH THE CONTRACT DRAWINGS

LSI #3052 CABINET DEPTH 14 1/4

PLAM PANEL 1' - 0" 6" 4" 2"

PLAM COUNTERTOP

COFFEE URNS N.I.C.

HDWD BASE TRIM ON WD BLKG RF-1

A12-17

1212

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111 Ph: 303.773.0436 | Fax: 303.773.8709

3. PROVIDE FINISHED END PANELS MATCHING THE CABINET FACE AT ALL EXPOSED CABINET SIDES.

COOLER N.I.C.

24

IN ASSOCIATION WITH:

7' - 0"

4. ALL EXPOSED EDGES AT COUNTER TOPS ARE TO HAVE EASED EDGE, TYP UON. 5. REFER TO THE TYPICAL MOUNTING HEIGHTS SCHEDULE FOR MOUNTING HEIGHTS OF ACCESSORIES AND DEVICES.

2' - 10"

2' - 6"

2-COMP SST SINK RE: PLBG DWGS

MOP SINK RE: 30/A10-01

1' - 8"

LSI #9837

COOLER N.I.C.

CONCESSIONS

MO-1

WR-3

RF-1

COOLER N.I.C.

2' - 6"

12" DEEP SST OVERSHELF

5' - 6"

1' - 0"

2. FLOOR FINISH, WALL FINISH AND WALL BASE ARE TO BE INSTALLED BENEATH AND BEHIND ALL BASE CABINETS AND/OR EQUIPMENT INDICATED TO BE REMOVABLE.

COUNTER SHUTTER

1212

BASE CABINET BEYOND

2' - 6"

F

CONCESSIONS

REMOVEABLE PLAM ACCESS PANEL DIE WALL CUTOUT AS REQ'D FOR CABLE MANAGEMENT PENCIL DRAWER

PLAM COUNTERTOP REVEAL PLAM PANEL ON 3/4" PLYWD DIE WALL

COUNTER SHUTTER

Lantz-Boggio Architects, P.C.

6. REFER TO ROOM FINISH SCHEDULE AND INTERIOR DESIGN DRAWINGS FOR ALL FINISHES THROUGHOUT THE BUILDING.

LSI #1052 CABINET DEPTH 24 1/4

LSI #1052 CABINET DEPTH 24 1/4

LSI #1052 CABINET DEPTH 24 1/4

LSI #1052 CABINET DEPTH 24 1/4

LSI #1052 CABINET DEPTH 24 1/4

LSI #1052 CABINET DEPTH 24 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

7. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A PULL PER SPEC.

3' - 0"

3' - 0"

3' - 0"

3' - 0"

2' - 6"

4' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

8. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A LOCK PER SPEC.

18' - 6"

12' - 0"

12' - 0"

NEW LARAMIE HIGH SCHOOL Laramie | Wyoming

42

36

1/2" = 1'-0"

CONCESSIONS INTERIOR ELEVATION

24

1/4" = 1'-0"

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

CONCESSIONS INTERIOR ELEVATION 1/4" = 1'-0"

8' - 6"

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

+30

37

13' - 2"

CONCESSIONS

A12-10

38

1212

1 LSI #9831 EXCEPT FULL WIDTH OF UNITS BELOW

42 A12-10

GROMMET WALL CLEATS AS REQUIRED TO SUPPORT COUNTERTOP

1147

PRINTER N.I.C.

TYP

A12-17

2' - 10"

FINISHED END PANEL

+42 10' - 8" FUTURE COMPUTER 40

SPACE FOR MOBILE COAT RACKS

3' - 5"

WR-3 +30

LSI #1052 CABINET DEPTH 13 1/4

LSI #1052 CABINET DEPTH 13 1/4

LSI #1052 CABINET DEPTH 13 1/4

LSI #1052 CABINET DEPTH 13 1/4

LSI #1052 CABINET DEPTH 13 1/4

LSI #1052 CABINET DEPTH 13 1/4

LSI #1052 CABINET DEPTH 13 1/4

3' - 0"

3' - 0"

3' - 0"

3' - 6"

3' - 0"

3' - 0"

3' - 0"

DIE WALL

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

COATS

1011

39

E

HEALTH/ LIFE-LONG LEARNING

FLOOR MOUNTED POPCORN MACHINE NIC

NOTE: ELEVATION TYPICAL OF BOTH SIDES OF ISLAND (O.H.)

1102

PROVIDE POWER AT END PANEL FOR POPCORN MACHINE

3/4" SCRIBE

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1001 CABINET 24 1/4

2' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

7' - 0"

RECEPTION

E

LSI #5060 CABINET DEPTH 14 1/4

23' - 0"

3/4" SCRIBE

1' - 6" A12-10

41

RECEPTION ENLARGED PLAN

35

1/4" = 1'-0"

CONCESSIONS MIDDLE ISLAND ELEVATION

23

1/4" = 1'-0"

HEALTH INTERIOR ELEVATION

11

1/4" = 1'-0"

A07-01

32

COATS NORTH 1/4" = 1'-0"

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

3 1/2" DISPLAY RAIL 2 SLIDING MARKER BOARDS; 1 SLIDING TACK BOARD BEHIND MARKER BOARDS;REFER TO SECTION 32/A12-17

LSI #3180 24" DEEP, 50" HIGH

A12-17

FINISHED END PANEL UTILITY SINK; TYP OF (3); RE: PLUMBING

3D ART WAITING 1100

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

LSI SHELF #3150 24" DEEP, 50" HIGH LSI #1520

1

37

1049

A12-17

SB-1

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

SIM TO LSI #5020 EXCEPT PROVIDE FIXED SHELVES AND PARTITIONS; ALL CABINETS 30" DEEP; TYP OF (5)

3D ART 1049

MB-1 LSI #9837

5' - 4"

12' - 0"

4' - 0"

12' - 0"

4' - 8 3/8"

LSI #1002 CABINET 24 4' - 0"

3/4" SCRIBE

LSI #1350 CABINET 24 1/4 1' - 7"

RE: LAPTOP STORAGE CABINET 6/A12-20 4' - 0"

LSI #1350 CABINET 24 1' - 7"

LSI #1350 CABINET 24 1' - 7"

IT CABINET

LSI RE: AV EQUIP #1350 CABINET CABINET 4/A12-20 24 1' - 7" 1' - 8"

2' - 0"

LSI #1012 CABINET 24 1' - 6"

LSI #1012 CABINET 24 1' - 6"

FINISHED END PANEL FILLER

22' - 7"

RECESS BASE 1/2" 3' - 5" 1212-B

COOLER (NIC)

STAINLESS STEEL COUNTERTOP

24

9 A07-11

OVERHEAD COILING DOOR A12-10

LSI #1132 CABINET DEPTH 24 1/4

LSI #1022 CABINET DEPTH 24 1/4

2' - 6"

3' - 0"

3' - 6"

3' - 6"

2' - 0"

3/4" SCRIBE 4' - 0"

4' - 0"

4' - 0"

2' - 6"

35 POPCORN

SD

22

HAND SINK

22' - 0" 35

1092 5' - 4"

A12-10

SIM TO LSI #1670 EXCEPT SET HEIGHT TO ACCOMMODATE 30" HIGH; SPACING OF DIVIDERS TO ALLOW FOR 3/4" DRAWING BOARD; TYP OF (2)

WR-3

REF

REF

PRINTER NIC

SD PTD

3' - 4"

36

3' - 4"

4' - 8"

12" DEEP SST OVERSHELF

1' - 0" LSI #1330 CABINET DEPTH 24 1/4

3' - 0"

1' - 9"

1/4" = 1'-0"

SPECIAL ED

2D ART

LSI #1002 CABINET DEPTH XXXX

FINISHED END PANEL WHERE EXPOSED FILLER

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

3' - 0"

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

C

3' - 0"

3' - 5"

1054

2' - 6" LSI #1490 PANEL DEPTH 24 1/4

3D ART INTERIOR ELEVATION ISSUED FOR CONSTRUCTION

PTD

3' - 6"

C

10

1/4" = 1'-0"

FD

1212

RECEPTION

3D ART INTERIOR ELEVATION

2' - 6"

CONCESSIONS

1212-A

GROMMET

20' - 0"

O.H.

7' - 0"

LSI #1756 DEPTH SAME AS LEDGE

4' - 0"

FD

WR-3

1102

4' - 0"

5' - 6"

10' - 4"

WD-4 BASE CABINETS WITH PLAM-2 COUNTERTOP

COOLER (NIC)

15' - 0"

FD

1' - 9"

LSI #1132 CABINET DEPTH 24 1/4

11' - 8"

COOLER (NIC)

1/4" = 1'-0"

1' - 9"

LSI #1136 CABINET DEPTH 24 1/4

1212-C

5' - 0"

RECEPTION INTERIOR ELEVATION

LSI LSI #1330 #1330 CABINET DEPTHCABINET DEPTH 24 1/4 24 1/4

LSI #1012 CABINET DEPTH 24 1/4

14' - 6"

10' - 7"

40

LSI #1350 CABINET 24 1' - 7"

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

2' - 10"

38' - 0 3/8" 42"

2' - 6"

1' - 0"

LSI #9832

7' - 2"

D

5' - 6"

D

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

FILLER

21' - 6"

LSI #1000 CABINET 13 1/4

SIM TO LSI #2001 EXCEPT PROVIDE FIXED SHELVES AND PARTITIONS; ALL CABINETS 30" DEEP; TYP OF (2)

3' - 0"

4' - 0"

3/4" SCRIBE

20' - 0"

7' - 0"

23' - 0"

39

RECEPTION INTERIOR ELEVATION 1/4" = 1'-0"

33

ENLARGED FOOTBALL CONCESSIONS

21

1/4" = 1'-0"

SPECIAL ED INTERIOR ELEVATION

9

1/4" = 1'-0"

ITEM

#

ADD

1

DATE

DESCRIPTION

31 JAN 2014 Addendum No. 1

2D ART INTERIOR ELEVATION 1/4" = 1'-0"

19' - 7" 2' - 3" LSI #3002 CABINET 14/4

2' - 3"

2' - 0"

3' - 0"

1' - 9"

2' - 6"

3' - 0"

2' - 10"

LSI #3002 CABINET 14/4

LSI #3002 CABINET 14/4

LSI #3002 CABINET 14/4

LSI #3002 CABINET 14/4

LSI #3002 CABINET 14/4

LSI #3002 CABINET 14/4

LSI #3002 CABINET 14/4

RECEPTION 1' - 7" 2' - 6"

42 A12-10 LSI #1330 CABINET DEPTH 24 1/4

LSI #1490 PANEL DEPTH 24 1/4

1' - 9"

3' - 0"

LSI #1330 CABINET DEPTH 24 1/4

A12-17

1054

A12-17

SB-1

SB-1

B

Seal:

CD-1 FILLER

2' - 3"

1' - 9"

CW-1 2' - 3"

DW-1 2' - 0"

LSI #1136 CABINET 24 1/4

LSI #1172 CABINET 24 1/4

3' - 0"

1' - 9"

RG-1 2' - 6"

LSI #1052 CABINET 24 1/4

RF-1

FILLER REQUIRED AT ODD ANGLED WALLS

LSI #1022 CABINET 24 1/4

1' - 6"

RE: LAPTOP STORAGE CABINET 18 /A12-17

4' - 0"

LSI #1350 CABINET 24 1/4

LSI #1350 CABINET 24 1/4

LSI #1350 CABINET 24 1/4

LSI #1350 CABINET 24 1/4

LSI RE: AV EQUIP #1350 CABINET CABINET 16 /A12-17 24 1/4

1' - 7" 1' - 7" 1' - 7" 1' - 7" 1' - 7"

3' - 0"

1' - 8"

IT CABINET 16 /A12-17

LSI #1012 CABINET 24 1/4

2' - 0" 1' - 10 1/2"

3/4" SCRIBE 3/4" SCRIBE

LSI #1002 CABINET 24

3' - 0"

FILLER

LSI #1002 CABINET 24

LSI #1022 CABINET 24

RE: LAPTOP STORAGE CABINET 18 /A12-17

3' - 0"

1' - 6"

4' - 0"

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

1' - 7" 1' - 7" 1' - 7" 1' - 7" 1' - 7"

RE: AV EQUIP CABINET 16 /A12-17

IT CABINET 16 /A12-17

LSI #1012 CABINET 24

LSI #1002 CABINET 24

LSI #1002 CABINET 24

1' - 8"

2' - 0"

1' - 8"

3' - 0"

3' - 0"

FILLER

30' - 9"

18' - 11 1/2"

16' - 9"

6' - 6"

38

PRINTER NIC

37

1092

3/4" SCRIBE

LSI #9876

2D ART

2' - 10"

GROMMET

A12-17

SPECIAL ED

37

3 1/2" DISPLAY RAIL 2 SLIDING MARKER BOARDS; 1 SLIDING TACK BOARD BEHIND MARKER BOARDS;REFER TO SECTION 32/A12-17

32

A12-17

2' - 7"

B

7' - 0"

TB-2

LSI #3180 24" DEEP, 50" HIGH

3 1/2" DISPLAY RAIL 2 SLIDING MARKER BOARDS; 1 SLIDING TACK BOARD BEHIND MARKER BOARDS;REFER TO SECTION 32/A12-17

LSI #3180 24" DEEP, 50" HIGH

32

1090

1102

LSI SHELF #3150 24" DEEP, 50" HIGH LSI #1520

LSI SHELF #3150 24" DEEP, 50" HIGH LSI #1520

LIFE SKILLS CLASS

RECEPTION INTERIOR ELEVATION 1/4" = 1'-0"

32

LIFE SKILLS INTERIOR ELEVATION

20

1/4" = 1'-0"

SPECIAL ED INTERIOR ELEVATION

8

1/4" = 1'-0"

2D ART INTERIOR ELEVATION Key Plan:

1/4" = 1'-0"

7' - 6" 2' - 6" LSI #3052 CABINET DEPTH 14 1/4

4' - 0"

2' - 0"

3/4" SCRIBE

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

3' - 0"

3' - 0"

3' - 0"

3' - 0"

37

RECEPTION INTERIOR ELEVATION 1/4" = 1'-0" 7

31

LSI #1000 CABINET 13 1/4

3' - 0"

LSI #1000 CABINET 13 1/4

3' - 0"

LSI #1000 CABINET 13 1/4

3' - 0"

LSI #1000 CABINET 13 1/4

FILLER

3/4" SCRIBE

LSI #1000 CABINET 23 1/4

2' - 6"

LSI #1000 CABINET 23 1/4

2' - 6"

LSI #1162 CABINET 24 1/4

3' - 0"

LSI #1062 CABINET 24 1/4

1' - 6"

LSI #1162 CABINET 24 1/4

3' - 0"

LSI #1062 CABINET 24 1/4

1' - 6"

LSI #1136 CABINET 24 1/4

3' - 0"

LSI #1000 CABINET 23 1/4

FILLER

SIM TO LSI #1480, EXCEPT 36" HIGH; ALL CABINETS 34 1/2" DEEP; TYP OF (2)

5

LSI #9831

3/4" SCRIBE

2' - 9"

4' - 0"

4' - 0"

4' - 0"

SIM TO LSI #2001 EXCEPT PROVIDE FIXED SHELVES AND PARTITIONS; ALL CABINETS 30" DEEP; TYP OF (7)

4' - 0"

22' - 3"

19

LSI #9832

5' - 6"

LSI #9831

3' - 0" LSI #1000 CABINET 23 1/4

2' - 6"

1/4" = 1'-0"

LBA Project Date

PRINTER NIC

LSI #9832 EXCEPT 35" DEEP

LSI #9837

3' - 0"

LIFE SKILLS INTERIOR ELEVATION 6

4' - 0"

SIM TO LSI #1670 EXCEPT SET HEIGHT TO ACCOMMODATE 30" HIGH; SPACING OF DIVIDERS TO ALLOW FOR 3/4" DRAWING BOARD; TYP OF (2)

24' - 0"

6' - 0"

4' - 0"

1054

2' - 10"

3' - 5" LSI #5110 CABINET DEPTH 24 1/4

8' - 0"

2D ART

2' - 6" 7' - 0"

7' - 0" FILLER

LSI #5062 CABINET DEPTH 24 1/4

LSI #3052 CABINET DEPTH 14 1/4

1054

1090

A

LSI #3052 CABINET DEPTH 14 1/4

2' - 6"

2D ART

LIFE SKILLS CLASS

1102

2' - 6"

1' - 8"

RECEPTION

2' - 6"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

9. PROVIDE SCRIBE / FILLER AT INTERSECTION OF WALLS / ADJACENT CASEWORK AS REQUIRED FOR FULL OPERATION

RECEPTION DESK DETAIL

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

4' - 0"

4' - 0"

4' - 0"

4' - 0"

INTERIOR PLANS AND ELEVATIONS

FILLER

3' - 0"

39' - 0"

2D ART INTERIOR ELEVATION

7

1/4" = 1'-0" 4

4' - 0"

LSI #1002 CABINET DEPTH 24 1/4

A

2012.32 15 JANUARY 2014

3

A12-10

2D ART INTERIOR ELEVATION 1/4" = 1'-0" 2

1


7

6

5

4

3

2

1

6' - 0"

GENERAL NOTES

3' - 0"

3' - 0"

LSI #3052 CABINET DEPTH 14 1/4

LSI #3052 CABINET DEPTH 14 1/4

LAUNDRY

2. FLOOR FINISH, WALL FINISH AND WALL BASE ARE TO BE INSTALLED BENEATH AND BEHIND ALL BASE CABINETS AND/OR EQUIPMENT INDICATED TO BE REMOVABLE.

LSI #9837

LSI #1101 CABINET DEPTH 24 1/4

LSI #1101 CABINET DEPTH 24 1/4

3' - 0"

3' - 0" 6' - 0"

PRINTER NIC.

LSI #9831 EXCEPT 18" DEEP

LSI #1101 CABINET 24 1/4

FILLER AT ODD ANGLED WALLS

LSI #1910 CABINET 17

LSI #1910 CABINET 17

LSI #1101 CABINET 24 1/4

LSI #1001 CABINET 24 1/4

LSI #1001 CABINET 24 1/4

LSI #2001 CABINET DEPTH 18

3/4" SCRIBE

FILLER AT ODD ANGLED WALLS

2' - 9"

LSI #2001 CABINET DEPTH 18

LSI #2001 CABINET DEPTH 18

LSI #2001 CABINET DEPTH 18

LSI #2001 CABINET DEPTH 18

LSI #2001 CABINET DEPTH 18

LSI #2001 CABINET DEPTH 18

LSI #2001 CABINET DEPTH 18

LSI #2001 CABINET DEPTH 18

LSI #1002 CABINET DEPTH 23 1/4

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

30

1/4" = 1'-0" 4' - 0"

3' - 0"

LSI CATALOG 8710 STOR. DEPTH 24 1/4

LSI CATALOG 8710 STOR. DEPTH 24 1/4

3' - 0"

3' - 0"

LSI CATALOG 8710 STOR. DEPTH 24 1/4

LSI CATALOG 8710 STOR. DEPTH 24 1/4

24

1/4" = 1'-0"

8. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A LOCK PER SPEC.

FILLER

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

CLASSROOM INTERIOR ELEVATION 1/4" = 1'-0"

SIM TO LSI #8710 EXCEPT 4'-0" WIDE CABINET DEPTH 24 1/4

3' - 0"

1' - 6"

LSI #3050 CABINET DEPTH 14 1/4

LSI #3050 CABINET DEPTH 14 1/4

LSI #3050 CABINET DEPTH 14 1/4

LSI #3050 CABINET DEPTH 14 1/4

LSI #3050 CABINET DEPTH 14 1/4

LSI #3050 CABINET DEPTH 14 1/4

LSI #3062 CABINET DEPTH 14 1/4

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

RECORDS STORAGE

3/4" SCRIBE

3' - 0"

LSI CATALOG 8710 STOR. DEPTH 24 1/4

3' - 0"

LSI #5052 CABINET 24 1/4

LSI #5062 CABINET 24 1/4

7' - 0"

LSI #5062 CABINET 24 1/4

3' - 0"

LSI #5062 CABINET 24 1/4

3' - 0"

LSI #5062 CABINET 24 1/4

3' - 0"

SIM TO LSI #8710 EXCEPT 4'-0" WIDE CABINET DEPTH 1/4 4' 24- 0"

3' - 0"

LSI #5062 CABINET 24 1/4

3' - 0"

LSI #5062 CABINET 24 1/4

3' - 0"

29 2' - 0"

4' - 0"

4' - 0"

4' - 0"

4' - 0"

LSI #8730 CABINET DEPTH 24 1/4

LSI #8730 CABINET DEPTH 24 1/4

LSI #8730 CABINET DEPTH 24 1/4

LSI #8870 CABINET DEPTH 24 1/4

E

FILLER 3/4" SCRIBE

3' - 0"

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

2' - 6"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

6' - 0"

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

3' - 0"

LSI #1002 CABINET DEPTH 23 1/4

3' - 0"

KNEE SPACE

2' - 10"

2' - 6"

FILE CABINETS (NIC)

KNEE SPACE

FILLER

3/4" SCRIBE 1' - 3" 1' - 3" 1' - 3" 1' - 3" 1' - 3"

3' - 0"

3' - 0"

3' - 9"

3' - 0"

1' - 3" 1' - 3" 1' - 3"

LSI #1101 CABINET DEPTH 24 1/4

LSI #1162 CABINET DEPTH 24 1/4

LSI #1101 CABINET DEPTH 24 1/4

LSI #1101 CABINET DEPTH 24 1/4

3' - 0"

3' - 0"

3' - 0"

3' - 0"

19' - 9"

29' - 6"

DESIGN LAB INTERIOR ELEVATION

23

1/4" = 1'-0"

CLASSROOM INTERIOR ELEVATION

11

1/4" = 1'-0"

RECORDS STOR INTERIOR ELEVATION

5

1/4" = 1'-0"

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

POOL LOBBY INTERIOR ELEVATION 1/4" = 1'-0"

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

8' - 3" 3' - 0"

PROVIDE UPPER CABINETS WITHOUT TOE KICK ASSEMBLY

3' - 0"

LSI #3050 CABINET DEPTH 14 1/4

CLASSROOM

2' - 3"

LSI #3050 CABINET DEPTH 14 1/4

LSI #3050 CABINET DEPTH 14 1/4

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

OFFICE

1077

1078

3/4" SCRIBE

LSI #1022 CABINET 24

LSI #1001 CABINET 24

LSI #1001 CABINET 24

LSI #1001 CABINET 24

LSI #1001 CABINET 24

LSI #1001 CABINET 24

LSI #1001 CABINET 24

LSI #1001 CABINET 24

LSI #1001 CABINET 24

1' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

LSI #1002 CABINET DEPTH 23 1/4

3/4" SCRIBE

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

3/4" SCRIBE

3' - 0"

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

2' - 0" 1' - 10 1/2"

25' - 0"

FILLER

SIM TO LSI #8730 CABINET DEPTH 24 1/4

4' - 0"

LSI #8730 CABINET DEPTH 24 1/4

2' - 0"

LSI #8730 CABINET DEPTH 24 1/4

4' - 0"

LSI #8730 CABINET DEPTH 24 1/4

4' - 0" 22' - 0"

4' - 0"

28

LSI #3052 CABINET DEPTH 14 1/4

LSI #3052 CABINET DEPTH 14 1/4

LSI #3052 CABINET DEPTH 14 1/4

2' - 10"

3' - 0"

3' - 6"

3' - 6"

4' - 0"

15' - 0"

LSI #1001 CABINET DEPTH 22 1/4

LSI #1001 CABINET DEPTH 22 1/4

LSI #1001 CABINET DEPTH 22 1/4

LSI #5062 CABINET DEPTH 24 1/4

3' - 0"

3' - 0"

2' - 3"

3' - 0"

3' - 0"

3/4" SCRIBE

11' - 3"

9' - 10 1/2"

DESIGN LAB INTERIOR ELEVATION

22

1/4" = 1'-0"

12' - 0" 3' - 0"

4' - 0"

FILLER

D

4' - 0"

1/4" = 1'-0"

3' - 0"

3' - 0"

A12-17

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

LSI #8870 CABINET DEPTH 24 1/4

ROBE STORAGE 3' - 0"

LSI #1000 CABINET 13 1/4

LSI #9837

33

3' - 5"

3' - 0" FILLER

LSI #8870 CABINET DEPTH 24 1/4

LSI #9831 EXCEPT 14" DEEP

LSI #9831

7' - 0"

1128

13' - 8 5/8"

PRINTER NIC

1064

STORAGE

DISTRIBUTED MEDIA/ LEARNING STREET

2' - 2"

DESIGN LAB

2' - 0"

1176A

3/4" PLYWD WITH HDWD EDGE CONTINUOUS

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

12' - 0"

3/4" SCRIBE

1/4" = 1'-0" SIM TO LSI #8730 CABINET DEPTH 24 1/4

LSI #1162 CABINET 24 1/4

3' - 0"

21' - 0"

ROBE STORAGE LSI #8870 CABINET DEPTH 24 1/4

LSI #1162 CABINET 24 1/4

3' - 0"

10' - 0"

4' - 0"

2199

LSI #9832

3' - 5"

2' - 10" 4' - 0"

LSI CATALOG 8710 STOR. DEPTH 24 1/4

LOBBY

1104

7' - 0"

7' - 0"

13' - 8"

LSI CATALOG 8710 STOR. DEPTH 24 1/4

3/4" SCRIBE

LSI #9837

3' - 0"

40

3' - 0"

1079 PRINTER NIC

LSI CATALOG 8710 STOR. DEPTH 24 1/4

D

3' - 0"

2' - 6"

1128

SET CABINETS IN PLYWD WALL MOUNT

3' - 0"

FILLER

CLASSROOM

PRINTER NIC

3/4" SCRIBE

41

3' - 0"

1058

7' - 0"

E

3' - 0"

DESIGN LAB STORAGE

PROVIDE 3/4" PLYWD WITH HDWD EDGE ABOVE LOWER CABINETS

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

19' - 6"

2' - 0"

PROVIDE UPPER CABINETS WITHOUT TOE KICK ASSEMBLY

Laramie | Wyoming

9. PROVIDE SCRIBE / FILLER AT INTERSECTION OF WALLS / ADJACENT CASEWORK AS REQUIRED FOR FULL OPERATION

4' - 0"

6' - 8"

WALL MOUNT & SET ON LOWER CABINET

NEW LARAMIE HIGH SCHOOL

7. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A PULL PER SPEC.

COLUMN ENCLOSURE

CLASSROOM INTERIOR ELEVATION

10

1/4" = 1'-0"

DIST MEDIA INTERIOR ELEVATION

4

1/4" = 1'-0"

OFFICE 1176A INTERIOR ELEVATION 1/4" = 1'-0"

ISSUED FOR CONSTRUCTION

LSI SHELF #3150 24" DEEP, 50" HIGH

3' - 0"

LSI #1520

LSI #3052 CABINET DEPTH 14 1/4

LSI #3180 24" DEEP, 50" HIGH

SPORTS MEDICINE

32

1195B

A12-17

3 1/2" DISPLAY RAIL 2 SLIDING MARKER BOARDS; 1 SLIDING TACK BOARD BEHIND MARKER BOARDS;REFER TO SECTION 32/A12-17

CLASSROOM

PRINTER NIC

3

2077

SD

DESIGN LAB

MB-1

PTD

1' - 8"

LSI #9837

37

1064

A12-17

SB-1

3' - 5"

2' - 6"

A12-17

7' - 0" C

2' - 10"

LSI #1002 CABINET DEPTH 23 1/4

FILLER

LSI #1000 CABINET 13 1/4

3' - 0" LSI #1052 CABINET DEPTH 24 1/4

3/4" SCRIBE

3' - 0"

LSI #1052 CABINET DEPTH 24 1/4

LSI #1052 CABINET DEPTH 24 1/4

3' - 0"

3' - 0"

LSI #1052 CABINET DEPTH 24 1/4

3' - 0"

12' - 0"

LSI #1002 CABINET 24 1/4

RE: LAPTOP STORAGE CABINET 18 /A12-17

3' - 6"

4' - 0"

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI RE: AV EQUIP #1350 CABINET CABINET 16 /A12-17 24

1' - 7" 1' - 7" 1' - 7" 1' - 7" 1' - 7" 0" 1' - 8"

IT CABINET 16 /A12-17

LSI #1002 CABINET 24 1/4

2' - 0"

3' - 6"

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

LSI #1000 CABINET 13 1/4

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

2' - 0"

3' - 0"

C 3/4" SCRIBE

23' - 0"

22' - 7"

27

1/4" = 1'-0"

DESIGN LAB INTERIOR ELEVATION

LSI SHELF #3150 24" DEEP, 50" HIGH

3 1/2" DISPLAY RAIL 2 SLIDING MARKER BOARDS; 1 SLIDING TACK BOARD BEHIND MARKER BOARDS;REFER TO SECTION 32/A12-17

3' - 0"

3' - 0"

LSI #3052 CABINET DEPTH 14 1/4

LSI #3052 CABINET DEPTH 14 1/4

2' - 0"

2' - 6"

LSI LSI #3052 #3052 CABINET DEPTH CABINET DEPTH 14 1/4 14 1/4

3' - 0"

2' - 3"

LSI #3052 CABINET DEPTH 14 1/4

LSI #3052 CABINET DEPTH 14 1/4

3' - 0"

3/4" SCRIBE

3' - 6"

4' - 0"

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI RE: AV EQUIP #1350 CABINET CABINET 16 /A12-17 24

1' - 7" 1' - 7" 1' - 7" 1' - 7" 1' - 7" 0" 1' - 8"

IT CABINET 16 /A12-17

LSI #1002 CABINET 24 1/4

2' - 0"

31 JAN 2014 Addendum No. 1

LSI #3180 24" DEEP, 50" HIGH

3 1/2" DISPLAY RAIL 2 SLIDING MARKER BOARDS; 1 SLIDING TACK BOARD BEHIND MARKER BOARDS;REFER TO SECTION 32/A12-17

32 A12-17

TB-7

TB-6

TB-6

TB-7

TB-6

TB-6

TB-7 SD

LSI #9837

PTD

37 A12-17

7' - 0"

TB-6

SB-1 PRINTER NIC

B

FINISHED END PANEL

3' - 6"

LSI #1101 CABINET DEPTH 24 1/4

LSI #1101 CABINET DEPTH 24 1/4

DW-1

3' - 0"

2' - 0"

3' - 0"

LSI #1101 CABINET DEPTH 24 1/4

LSI #1101 CABINET DEPTH 24 1/4

SIM TO LSI #1340 EXCEPT 27" WIDE CABINET DEPTH 24 1/4

2' - 6"

3' - 0"

2' - 3"

LSI #5062 CABINET 24 1/2

FILLER

3/4" SCRIBE

LSI #5072 CABINET 24 1/2

3' - 0"

LSI #5062 CABINET 24 1/2

2' - 0"

LSI #5072 CABINET 24 1/2

3' - 0"

LSI #5062 CABINET 24 1/2

2' - 0"

15' - 9"

22' - 7"

Seal:

2' - 10"

2' - 10" RF-1

FILLER

1

DESCRIPTION

1039

7' - 0"

1' - 8"

LSI #9837

1093

RE: LAPTOP STORAGE CABINET 18 /A12-17

LSI #3052 CABINET DEPTH 14 1/4

2' - 6"

2' - 6"

B

TB-6

MO-1

WORKROOM/ PLANNING/ STORAGE

SB-1

LSI #1002 CABINET 24 1/4

1' - 9"

LSI #3052 CABINET DEPTH 14 1/4

TACKBOARD W/ HARDWOOD FRAME

1058

ADD

DATE

LSI SHELF #3150 24" DEEP, 50" HIGH LSI #1520

DESIGN LAB

DESIGN LAB

#

1/4" = 1'-0"

15' - 9"

LSI #1520 LSI #3180 24" DEEP, 50" HIGH

21

1/4" = 1'-0"

ITEM

CLASSROOM INTERIOR ELEVATION

1' - 8"

39

SPORTS MEDICINE INTERIOR ELEVATION

LSI #5072 CABINET 24 1/2

3' - 0"

LSI #1136 CABINET 24 1/4

2' - 0"

LSI #1172 CABINET 24 1/4

3' - 0"

3/4" SCRIBE

LSI #1350 CABINET 24

FILLER

LSI #1350 CABINET 24

LSI #1350 CABINET 24

RE: LAPTOP STORAGE CABINET 18 /A12-17

1' - 7" 1' - 7" 1' - 7"

1' - 9"

4' - 0"

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

1' - 7" 1' - 7" 1' - 7" 1' - 7" 1' - 7"

RE: AV EQUIP CABINET 16 /A12-17

IT CABINET 16 /A12-17

LSI #1012 CABINET 24 1/4

LSI #1350 CABINET 24

LSI #1350 CABINET 24

1' - 8"

2' - 0"

2' - 3"

1' - 7" 1' - 7"

3/4" SCRIBE

25' - 10"

19' - 9" POWER FOR SEWING MACHINES SPACE FOR 2 SEWING MACHINES, STACKED (14"h X 13"w X 17"d)

38

DESIGN LAB INTERIOR ELEVATION

26

1/4" = 1'-0"

WORKROOM PLANNING / STORAGE INTERIOR ELEVATION 1/4" = 1'-0"

20

DESIGN LAB INTERIOR ELEVATION

8

1/4" = 1'-0"

TYPICAL CLASSROOM INTERIOR ELEVATION Key Plan:

1/4" = 1'-0" LSI SHELF #3150 24" DEEP, 50" HIGH LSI #1520

32

3 1/2" DISPLAY RAIL 2 SLIDING MARKER BOARDS; 1 SLIDING TACK BOARD BEHIND MARKER BOARDS;REFER TO SECTION 32/A12-17

A12-17 LSI #3180 24" DEEP, 50" HIGH

23 WALL TYPE VARIES, RE: PLAN

PRINTER NIC

DESIGN LAB

A12-17

3

2

1

A12-17

A12-17

A12-17

LEVEL 2

LEVEL 2

1039

TYP PRINTER NIC

TB-6

TB-6

TB-7

TB-6

TB-6

TB-7

TB-6

TB-6

TB-7

TB-6

TB-6

TB-7

TB-6

TB-6

PRINTER NIC

37

TB-7

A12-17

LBA Project Date

37 A12-17

LSI #9837 EXCEPT 18" DEEP

LEVEL 1

SB-1

A

A 3' - 5"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

42

DESIGN LAB INTERIOR ELEVATION

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

6. REFER TO ROOM FINISH SCHEDULE AND INTERIOR DESIGN DRAWINGS FOR ALL FINISHES THROUGHOUT THE BUILDING.

29' - 9"

LAUNDRY INTERIOR ELEVATION

IN ASSOCIATION WITH:

5. REFER TO THE TYPICAL MOUNTING HEIGHTS SCHEDULE FOR MOUNTING HEIGHTS OF ACCESSORIES AND DEVICES.

LSI #9831

LSI #1910 CABINET 17

Ph: 303.773.0436 | Fax: 303.773.8709

4. ALL EXPOSED EDGES AT COUNTER TOPS ARE TO HAVE EASED EDGE, TYP UON.

3' - 5"

2' - 10"

F

1039 LSI #9831

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

3. PROVIDE FINISHED END PANELS MATCHING THE CABINET FACE AT ALL EXPOSED CABINET SIDES.

DESIGN LAB

7' - 0"

1' - 8"

2' - 6"

1041A

3/4" SCRIBE

Lantz-Boggio Architects, P.C.

1. VERIFY MOUNTING HEIGHTS AND CLEARANCES AT ALL LOCATIONS; NOTIFY THE ARCHITECT OF ANY DISCREPANCIES WITH THE CONTRACT DRAWINGS

LSI #1001 CABINET DEPTH XXXX

FILLER

3' - 0"

LSI #2001 TYP

3' - 0"

LSI #2001 TYP

3' - 0"

LSI #2001 TYP

LSI #2001 TYP

3' - 0"

3' - 0"

LSI #2001 TYP

3' - 0"

LSI #2001 TYP

3' - 0"

LSI #2001 TYP

3/4" SCRIBE

2' - 0"

2' - 0"

23' - 0"

37

LSI #2001 TYP

LSI #2001 TYP

3' - 0"

LSI #2001 TYP

3' - 0"

LSI #2001 TYP

3' - 0"

LSI #2001 TYP

3' - 0"

LSI #2001 TYP

3' - 0"

LSI #2001 TYP

3' - 0"

LSI #1001 CABINET DEPTH XXXX

3' - 0"

3/4" SCRIBE

16 1/2" AT L1 13 1/4" AT L2

LSI #5062 CABINET 24 1/2

LSI #5072 CABINET 24 1/2

LSI #5062 CABINET 24 1/2

LSI #5072 CABINET 24 1/2

LSI #5062 CABINET 24 1/2

LSI #5072 CABINET 24 1/2

LSI #5062 CABINET 24 1/2

LSI #5072 CABINET 24 1/2

LSI #5062 CABINET 24 1/2

LSI #5072 CABINET 24 1/2

LSI #1910 CABINET 17

LSI #1910 CABINET 17

3/4" SCRIBE

FILLER

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

1' - 7" 1' - 7" 1' - 7"

19

1/4" = 1'-0" 6

RE: LAPTOP STORAGE CABINET 18 /A12-17

4' - 0"

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

1' - 7" 1' - 7" 1' - 7" 1' - 7" 1' - 7"

RE: AV EQUIP CABINET 16 /A12-17

IT CABINET 16 /A12-17

1' - 8"

2' - 0"

LSI #1012 CABINET 24 1/4

LSI #1350 CABINET 24

LSI #1350 CABINET 24

INTERIOR ELEVATIONS

FILLER

2' - 3 3/4" 1' - 6 1/4" 1' - 8"

25' - 10"

23' - 0"

TYPICAL CLASSROOM INTERIOR ELEVATION 7

FILLER

2012.32 15 JANUARY 2014

5

DESIGN LAB INTERIOR ELEVATION

7

1/4" = 1'-0" 4

3

A12-11

TYPICAL CLASSROOM INTERIOR ELEVATION 1/4" = 1'-0" 2

1


7

6

5

4

3

2

1

12' - 0"

KEWAUNEE #W25W301248 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241224 CABINET DEPTH 12 3/4

KEWAUNEE #W25W301236 CABINET DEPTH 12 3/4

BEAKER DRYING RACK

30" DEEP EPOXY COUNTER

3' - 0"

3' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

3' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

3/4" SCRIBE

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 6"

3' - 0"

KEWAUNEE #G00W362236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #E41W362248 CABINET DEPTH 22

3' - 0"

KEWAUNEE #G00W362236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #G00W362236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #G00W362236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #E41W242224 CABINET DEPTH 22

3' - 0"

RF-1

DW-1

2'-0" X 3'-0" CART (NIC)

3' - 0"

33' - 6"

FINISHED END PANEL

KEWAUNEE #G00W362236 CABINET DEPTH 22

4' - 0"

21' - 0"

3' - 0"

KEWAUNEE #S25W842236 CABINET DEPTH 22

KEWAUNEE #S40W842236L CABINET DEPTH 22

3' - 0"

3' - 0"

3' - 0"

2' - 0"

3/4" SCRIBE

FINISHED WOOD PANEL

SCIENCE INTERIOR ELEVATION

SCIENCE INTERIOR ELEVATION

36

1/4" = 1'-0"

24

1/4" = 1'-0"

NEW LARAMIE HIGH SCHOOL

7. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A PULL PER SPEC.

BLACK RUBBER BASE AT TOE KICK, TYP ALL SIDES

8. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A LOCK PER SPEC.

Laramie | Wyoming

9. PROVIDE SCRIBE / FILLER AT INTERSECTION OF WALLS / ADJACENT CASEWORK AS REQUIRED FOR FULL OPERATION

18' - 0"

3/4" SCRIBE

42

KEWAUNEE #E41W362236 CABINET DEPTH 22

SCIENCE PREP INTERIOR ELEVATION

3

1/4" = 1'-0"

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

MILLWORK ELEVATION 3/4" = 1'-0"

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

19' - 0" 3' - 0"

4' - 0"

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241248 CABINET DEPTH 12 3/4

6' - 3" CTOP 4' - 0"

2' - 5" CTOP

A12-17

1' - 4"

TYP

MO-2

LOCKABLE DOOR

TRASH CUT-OUT W/ 1 1/2" LAMINATED EDGE, TYP OF (2)

R 4 1/2"

3/4" SCRIBE

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #G07W342236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

2'-0" X 3'-0" CART (NIC)

KEWAUNEE #E41W362242 CABINET DEPTH 22

KEWAUNEE #A00W0336-00_0 APRON

KEWAUNEE #D81W312218 CABINET DEPTH 22

3' - 0"

3' - 6"

KEWAUNEE #A00W0336-00_0 APRON

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362248 CABINET DEPTH 22

COMBUSTIBLE STORAGE CABINET (NIC)

3' - 0"

3' - 0"

3' - 0"

4' - 0"

3' - 7"

1' - 5 1/4" 1' - 6 3/4"

KEWAUNEE #E41W362242 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 6"

3' - 0"

3' - 0"

22' - 7"

18' - 6"

41

3/4" SCRIBE

3/4" SCRIBE

SCIENCE INTERIOR ELEVATION

KEWAUNEE #E41W362236 CABINET DEPTH 22

4' - 0"

KEWAUNEE #E41W362224 CABINET DEPTH 22

3' - 0"

FINISHED END PANEL

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

3' - 0"

3' - 0"

1' - 0"

23

1/4" = 1'-0"

A12-12

E

FILLER A12-12

SCIENCE INTERIOR ELEVATION

2

1/4" = 1'-0"

MILLWORK ELEVATION

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

MILLWORK DETAIL

1

3/4" = 1'-0"

3/4" = 1'-0"

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

30' - 0"

7'-10" CASEWORK 3' - 3"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W20W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W20W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W20W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W20W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

TABLES FOR GREENHOUSE PLANTS (NIC) DATA / POWER AT APRON

SCIENCE

39

A12-12

FILLER

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #G00W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

3' - 0"

3' - 0"

3' - 0"

KEWAUNEE #G00W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #G00W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

2' - 0"

1053 DATA / POWER AT APRON

FILLER

KEWAUNEE #E41W362236 CABINET DEPTH 22

FILLER 3/4" SCRIBE

KEWAUNEE #G00W362236 CABINET DEPTH 22

3' - 0"

3' - 0"

40

SCIENCE INTERIOR ELEVATION

34

1/2" = 1'-0"

KEWAUNEE #G00W362236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #E40W362212R CABINET DEPTH 22

KEWAUNEE #G00W362248 CABINET DEPTH 22

FINISHED END PANEL 1' - 0"

3' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

4' - 0"

22

1/4" = 1'-0"

KEWAUNEE #G00W362236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

3' - 0"

3' - 0" KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

3/4" DIAMETER VERTICAL RODS & CROSSBAR 3' - 0"

3' - 0"

3' - 0"

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

3' - 0"

3' - 0"

KEWAUNEE #W20W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

3' - 0"

KEWAUNEE #W20W241236 CABINET DEPTH 12 3/4

3' - 0"

KEWAUNEE #W20W241236 CABINET DEPTH 12 3/4

3' - 0"

KEWAUNEE #W20W241236 CABINET DEPTH 12 3/4

3' - 0"

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

10

3' - 0" KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

32 A12-17

EMERGENCY EYE WASH

2' - 4"

3' - 0"

DATA / POWER AT APRON; TYP

2050

VENT

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #G00W362236 CABINET DEPTH 22

KEWAUNEE #G00W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #G00W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

RE: LAPTOP CABINET 18 /A12-17

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

4' - 0"

SCIENCE INTERIOR ELEVATION

21

1/4" = 1'-0"

BEAKER DRYING RACK

LSI #1350 CABINET 24

LSI #1350 CABINET 24

EMERGENCY EYE WASH SB-1

FINISHED END PANEL TYP AT RECESS

A12-17

3' - 0"

3' - 0"

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

30" DEEP EPOXY COUNTER

ISSUED FOR CONSTRUCTION

LSI #1520

3 1/2" DISPLAY RAIL

LSI #3180 24" DEEP, 50" HIGH

2 SLIDING MARKER BOARDS; 1 SLIDING TACK BOARD BEHIND MARKER BOARDS;REFER TO SECTION 32/A12-17

32 BEAKER DRYING RACK SD PTD

A12-17

37

1050

A12-17

SB-1

SD PTD

C

FH-1 OR FH-2 (RE: FLOOR PLAN) KEWAUNEE ACID STORAGE CABINET #G80W362230_019625 CABINET DEPTH 22 TYP OF (2)

RE: LAPTOP CABINET 18 /A12-17

5' - 0"

4' - 0"

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

RE: AV EQUIP CABINET 16 /A12-17

IT CABINET 16 /A12-17

LSI #1012 CABINET 24

KEWAUNEE ACID STORAGE CABINET #G80W362230_019625 CABINET DEPTH 22 TYP OF (2)

1' - 8"

2' - 0"

1' - 3"

5' - 0"

EMERGENCY EYE WASH

FILLER

3/4" SCRIBE APRON FOR FH-2 CONTROLS

LSI #1001 CABINET 24

RE: LAPTOP CABINET 18 /A12-17

3' - 0"

4' - 0"

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI RE: AV EQUIP #1350 CABINET 16 /A12-17 CABINET 24

1' - 7" 1' - 7" 1' - 7" 1' - 7" 1' - 7"

IT CABINET 16 /A12-17

1' - 8"

LSI #1001 CABINET 24

2' - 0"

3/4" SCRIBE

3' - 0"

21' - 7"

ITEM

LSI LSI #1350 #1350 CABINET CABINET 24 24

RE: AV EQUIP CABINET 16 /A12-17

1' - 7" 1' - 7" 1' - 7" 1' - 7" 1' - 7" 1' - 7"

1' - 8"

IT CABINET 16 /A12-17

2' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

LSI #1012 CABINET 24

1/4" = 1'-0"

3 1/2" DISPLAY RAIL

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

2 SLIDING MARKER BOARDS; 1 SLIDING TACK BOARD BEHIND MARKER BOARDS;REFER TO SECTION 32/A12-17

32

LSI #3180 24" DEEP, 50" HIGH

BEAKER DRYING RACK

PREP

EMERGENCY EYE WASH

2051A

FH-1 OR FH-2 (RE: FLOOR PLAN) KEWAUNEE ACID STORAGE CABINET #G80W362230_019625 CABINET DEPTH 22 TYP OF (2)

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #D81W312218 CABINET DEPTH 22

1052

PTD SD

KEWAUNEE KEWAUNEE #A00W0336-00_0 #D81W312218 APRON CABINET DEPTH 22

COMBUSTIBLE STORAGE CABINET (NIC)

3/4" SCRIBE

FINISHED END PANEL 3' - 0"

3' - 0"

3' - 0"

1' - 6" 1' - 6"

3' - 0"

1' - 6"

LSI #1001 CABINET 24

RE: LAPTOP CABINET 18 /A12-17

LSI #1350 CABINET 24

LSI #1350 CABINET 24

3' - 0"

4' - 0"

1' - 7" 1' - 7" 1' - 7" 1' - 7" 1' - 7"

3' - 0"

3' - 0"

3' - 0"

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

LSI #1350 CABINET 24

LSI #1350 CABINET 24

LSI RE: AV EQUIP #1350 CABINET 16 /A12-17 CABINET 24

1' - 8"

IT CABINET 16 /A12-17

LSI #1001 CABINET 24

2' - 0"

3' - 0"

21' - 7"

21' - 6"

SCIENCE PREP INTERIOR ELEVATION

8

1/4" = 1'-0"

17' - 9"

B

Seal:

REMOVEABLE BACK

KEWAUNEE #A00W0336-00_0 APRON

A12-17

SCIENCE

WORK STATIONS WITH EPOXY COUNTER AND BACKSPLASH

5' - 0"

1/4" = 1'-0"

DESCRIPTION

SCIENCE INTERIOR ELEVATION

3' - 0"

REMOVEABLE BACK

1' - 3"

20

DATE

LSI SHELF #3150 24" DEEP, 50" HIGH LSI #1520

4" HIGH EPOXY BACKSPLASH

VENT

3/4" SCRIBE

SCIENCE INTERIOR ELEVATION

#

37

2' - 10"

VENT

2' - 10"

3' - 0"

3' - 0"

23' - 5"

32

FILLER

2' - 3"

LSI SHELF #3150 24" DEEP, 50" HIGH

9

FH-2

2052 7' - 0"

7' - 6"

1"

3/4" SCRIBE

4"

2' - 7"

PTD SD

2' - 6"

TEACHING STATION END PANEL

KEWAUNEE #E40W312227 CABINET DEPTH 22

3' - 0"

A12-17

SIDESPLASH

37

SCIENCE

FH-2

LSI #1350 CABINET 24

1' - 7" 1' - 7" 1' - 7" 1' - 7" 1' - 7" 1' - 7"

3' - 0"

EXHAUST DUCT ENCLOSURE APRON FOR FH-2 CONTROLS

A12-17

WOOD FINISHED PANEL

B

3' - 0"

2' - 0"

3' - 0"

1" THICK EPOXY COUNTER

3' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

15' - 0"

3 1/2" DISPLAY RAIL 2 SLIDING MARKER BOARDS; 1 SLIDING TACK BOARD BEHIND MARKER BOARDS;REFER TO SECTION 32/A12-17

LSI #3180 24" DEEP, 50" HIGH

32

1/2" = 1'-0"

LSI #1350 CABINET 24

1/4" = 1'-0"

LSI SHELF #3150 24" DEEP, 50" HIGH LSI #1520

APRON FOR FH-2 CONTROLS EXHAUST DUCT SOFFIT ENCLOSURE PANEL

3/4" DIAMETER VERTICAL RODS & CROSSBAR

38

LSI #1350 CABINET 24

SCIENCE INTERIOR ELEVATION

2' - 2"

33

3' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

23' - 5"

UPRIGHT ROD ASSEMBLY KEWAUNEE #4740-00

4" RUBBER CASTERS; LOCKABLE

LSI #1350 CABINET 24

30' - 0"

1/2" = 1'-0"

3' - 0"

KEWAUNEE #G00W362236 CABINET DEPTH 22

1/4" = 1'-0"

FH-2

SCIENCE

FILLER

7' - 10"

39

3' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

2' - 10" 3/4" SCRIBE

TEACHING STATION ELEVATION

3' - 0"

KEWAUNEE #G00W362236 CABINET DEPTH 22

2' - 10"

2' - 6"

KEWAUNEE #E41W362236 CABINET DEPTH 22

SCIENCE INTERIOR ELEVATION

2' - 6"

KEWAUNEE #G78W362836 CABINET DEPTH 27 1/2 (NO SINK)

3' - 0"

KEWAUNEE #G00W362236 CABINET DEPTH 22

SCIENCE

2' - 0" KEWAUNEE #A00W052230 APRON 20 5/8

3' - 0"

SB-1

2' - 10" KEWAUNEE #G71W362830 CABINET DEPTH 27 1/2

KEWAUNEE #E41W362236 CABINET DEPTH 22

3 1/2" DISPLAY RAIL 2 SLIDING MARKER BOARDS; 1 SLIDING TACK BOARD BEHIND MARKER BOARDS;REFER TO SECTION 32/A12-17 EXHAUST DUCT SOFFIT ENCLOSURE PANEL BEAKER DRYING RACK

LSI #3180 24" DEEP, 50" HIGH

37

2' - 2"

7' - 0"

3' - 0"

KNEE SPACE

KEWAUNEE #E41W362236 CABINET DEPTH 22

LSI SHELF #3150 24" DEEP, 50" HIGH LSI #1520

A12-17 C

1' - 6"

1/4" = 1'-0"

2050

4" RUBBER CASTERS; LOCKABLE

KEWAUNEE #G00W362236 CABINET DEPTH 22

FILLER

3' - 0"

SCIENCE INTERIOR ELEVATION

SCIENCE

1" THICK EPOXY COUNTER

3/4" SCRIBE

32' - 3"

30' - 0" UPRIGHT ROD ASSEMBLY KEWAUNEE #4740-00

KEWAUNEE #E40W362218R CABINET DEPTH 22

15' - 6"

12' - 0"

30' - 0"

TEACHING STATION PLAN

KEWAUNEE #E41W362236 CABINET DEPTH 22

D

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

2' - 10"

EPOXY COUNTER

SCIENCE

3' - 0"

ROD SOCKETS KEWAUNEE #0548-00

3' - 0"

2050

2' - 10"

2' - 4"

2' - 10"

2' - 6"

7' - 0"

DATA / POWER AT APRON

7' - 0"

2' - 2"

D

SCIENCE

2' - 2"

A12-12

2' - 0"

38

2052

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

7' - 6"

4' - 5"

2'-6" CASEWORK

2' - 8"

4"

3' - 0" KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

2' - 10"

8' - 0"

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

3

10' - 0"

16' - 6"

SCIENCE PREP INTERIOR ELEVATION

35

1/4" = 1'-0"

KEWAUNEE #E41W362248 CABINET DEPTH 22

2

WR-3 BELOW TYP OF (2)

4"

2' - 10"

2' - 6"

2' - 10"

20

2' - 10"

30" DEEP EPOXY COUNTER

2' - 10"

E

4" HIGH EPOXY BACKSPLASH

RECESSED OPENING FOR MO-2, FINISHED WOOD ALL EXPOSED SIDES

1' - 10"

11 1/2"

WORK STATIONS WITH EPOXY COUNTER AND BACKSPLASH

DATA / POWER AT APRON

1' - 3"

2' - 3"

7' - 0"

1050A

2050

2051

TABLES FOR GREENHOUSE PLANTS (N.I.C.)

7' - 0"

PREP

SCIENCE

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

2' - 1"

SCIENCE

2' - 2"

BEAKER DRYING RACK 4" HIGH EPOXY BACKSPLASH 30" DEEP EPOXY COUNTER PTD

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

3' - 0" KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

2' - 0"

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

3' - 0"

2' - 0"

3' - 0"

2' - 2"

3' - 0"

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

6. REFER TO ROOM FINISH SCHEDULE AND INTERIOR DESIGN DRAWINGS FOR ALL FINISHES THROUGHOUT THE BUILDING.

FILLER KEWAUNEE #E41W362236 CABINET DEPTH 22

IN ASSOCIATION WITH:

5. REFER TO THE TYPICAL MOUNTING HEIGHTS SCHEDULE FOR MOUNTING HEIGHTS OF ACCESSORIES AND DEVICES.

4"

KEWAUNEE #G07W342236 CABINET DEPTH 22

Ph: 303.773.0436 | Fax: 303.773.8709

4. ALL EXPOSED EDGES AT COUNTER TOPS ARE TO HAVE EASED EDGE, TYP UON.

2' - 10"

2' - 10"

2' - 10"

KEWAUNEE #E41W362236 CABINET DEPTH 22

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

3. PROVIDE FINISHED END PANELS MATCHING THE CABINET FACE AT ALL EXPOSED CABINET SIDES.

2' - 10"

SD

PTD F

2' - 2"

PTD

SCIENCE INTERIOR ELEVATION Key Plan:

1/4" = 1'-0"

12' - 0" 2' - 9" KEWAUNEE #W25W241233 CABINET DEPTH 12 3/4

3' - 0"

3' - 0"

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

3' - 0"

2' - 0"

3' - 0"

4' - 0"

KEWAUNEE #W25W301236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241224 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W301248 CABINET DEPTH 12 3/4

EXHAUST DUCT APRON FOR FH-2 CONTROLS

BEAKER DRYING RACK

30" DEEP COUNTER

PREP 2050A

SCIENCE

TB-1

2' - 6"

2' - 0"

2050A

4" HIGH EPOXY BACKSPLASH

MB-1

DATA / POWER AT APRON

COMBUSTIBLE STORAGE CABINET (N.I.C)

KEWAUNEE #A00W0336-00_0 APRON

KEWAUNEE #D81W312218 CABINET DEPTH 22

KEWAUNEE #A00W0336-00_0 APRON

3' - 0"

1' - 6" 1' - 6"

3' - 0"

KEWAUNEE #E41W362233 CABINET DEPTH 22

2' - 9"

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE ACID STORAGE CABINET #G80W362230_019625 CABINET DEPTH 22 TYP OF (2)

3' - 0"

3' - 0"

5' - 0"

7' - 0" 2' - 2"

PTD

3/4" SCRIBE

3/4" SCRIBE

19

20

21

A12-17

A12-17

A12-17

TYP

TYP

TYP

A

2' - 10"

1' - 8"

SD

2' - 10"

2' - 10"

VENT

7' - 0"

30" DEEP EPOXY COUNTER

7' - 0"

4" HIGH EPOXY BACKSPLASH

WORK STATIONS GROMMETS

2' - 2"

FH-2 A

LBA Project Date

1050

2' - 0"

ENCLOSURE

PREP

2' - 6"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

1 1/2"

4" HIGH EPOXY BACKSPLASH

Lantz-Boggio Architects, P.C.

2. FLOOR FINISH, WALL FINISH AND WALL BASE ARE TO BE INSTALLED BENEATH AND BEHIND ALL BASE CABINETS AND/OR EQUIPMENT INDICATED TO BE REMOVABLE.

LOCKABLE DOOR

TB-1

1053

1. VERIFY MOUNTING HEIGHTS AND CLEARANCES AT ALL LOCATIONS; NOTIFY THE ARCHITECT OF ANY DISCREPANCIES WITH THE CONTRACT DRAWINGS

SOLID SURFACE CTOP W/ 1 1/2" LAMINATED EDGE

7' - 0"

SCIENCE

EPOXY DOUBLE TUB SINK

3' - 0"

2' - 4 1/2"

DATA / POWER AT APRON

2' - 0"

7' - 0"

2051A

3' - 0"

2' - 0"

1052

2' - 0"

PREP

2' - 2"

4" HIGH EPOXY BACKSPLASH 30" DEEP EPOXY COUNTER REMOVEABLE PANEL

SCIENCE

GENERAL NOTES

4' - 0"

KEWAUNEE #S40W842236L CABINET DEPTH 22

KEWAUNEE #S25W842236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

DW-1

KEWAUNEE #G00W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

3' - 0"

3' - 0"

2' - 0"

3' - 0"

4' - 0"

RF-1 FINISHED END PANEL

FILLER

2'-0" X 3'-0" CART (NIC)

KEWAUNEE #E41W242236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #G00W362236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #G00W362236 CABINET DEPTH 22

3' - 0"

18' - 0"

KEWAUNEE #E41W362248 CABINET DEPTH 22

3' - 0"

KEWAUNEE #G00W362236 CABINET DEPTH 22

KEWAUNEE #E41W362240 CABINET DEPTH 22

3' - 0"

3' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #G00W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

4' - 6"

31 7

19

1/4" = 1'-0" 6

5

SCIENCE PREP INTERIOR ELEVATION

7

1/4" = 1'-0" 4

INTERIOR ELEVATIONS

3/4" SCRIBE

3' - 0"

34' - 6"

22' - 9"

SCIENCE PREP INTERIOR ELEVATION

KEWAUNEE #E41W362236 CABINET DEPTH 22

2012.32 15 JANUARY 2014

3

A12-12

SCIENCE INTERIOR ELEVATION 1/4" = 1'-0" 2

1


NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

42

R U1

7

4'-11" TYP.

R U1.1

R

R U1.1

U1.1

R

R U1

R U1

R U1

R U1.1

R U1.1

LSI #8162 DEPTH 41

1' - 9"

LSI #8162 DEPTH 41

1' - 9"

LSI #8166 DEPTH 41

1' - 9"

LSI #8166 DEPTH 41

1' - 9"

LSI #8166 DEPTH 41

1' - 9"

LSI #8166 DEPTH 41

1' - 9"

LSI #8166 DEPTH 41

1' - 9"

LSI #8166 DEPTH 41

1' - 9"

LSI #8166 DEPTH 41

1' - 9"

LSI #8166 DEPTH 41

R U1.1

LSI #8162 DEPTH 41

1' - 9"

R U1

U1

R U1

LSI #8162 DEPTH 41

1' - 9"

R U1.1

INSTRUMENTAL ACOUSTICAL PANELING 1/4" = 1'-0"

R U1

ORCHESTRA

LSI #8162 DEPTH 41

1' - 9"

4' - 11" TYP

LSI #8162 DEPTH 41

1' - 9"

1136

LSI #8162 DEPTH 41

1' - 9"

6

LINE OF STRUCTURAL STEEL BRACED FRAME BEYOND

1130

INSTRUMENTAL

12' - 6" COLUMN ENCLOSURE; RE: PLAN

3/4" SCRIBE

30

29

28

27

5

3/4" SCRIBE

END

INSTRUMENT STORAGE 1/4" = 1'-0"

3' - 6"

FLUSH OUT BACKS OF LSI #8621 TO MATCH

LSI #8122 CABINET DEPTH 31

1' - 9"

LSI #8182 DEPTH 31

1' - 9"

LSI #8182 DEPTH 31

1' - 9"

LSI #8182 DEPTH 31

1' - 9"

LSI #8160 DEPTH 31

1' - 9"

LSI #8160 DEPTH 31

1138

INSTRUMENT STORAGE

2' - 3" 13' - 3"

LSI #8122 CABINET DEPTH 31

INSTRUMENT STORAGE 1138

LSI #8502 CABINET DEPTH 21

2' - 3"

2' - 3"

FILLER

2' - 3"

LSI #8126 CABINET DEPTH 41

2' - 3"

LSI #8126 CABINET DEPTH 41

4

LSI #8146 CABINET DEPTH 41

LSI #8502 CABINET DEPTH 21

2' - 3"

2' - 3"

LSI #9831 EXCEPT FULL WIDTH OF UNITS BELOW

2' - 3"

LSI LSI #8522 #8502 CABINET DEPTH CABINET DEPTH 41 21

2' - 3"

LSI #8146 CABINET DEPTH 41

LSI #8522 CABINET DEPTH 41

2' - 3"

2' - 3"

LSI #8162 CABINET DEPTH 41

LSI #8502 CABINET DEPTH 21

2' - 3"

NOTE: ELEVATION TYPICAL OF BOTH SIDES OF ISLAND (O.H.)

2' - 3"

13' - 6"

LSI #8162 CABINET DEPTH 41

INSTRUMENT STORAGE 1/4" = 1'-0"

INSTRUMENT STORAGE 1138

3/4" SCRIBE 2' - 3"

LSI #8110 CABINET DEPTH 31

LSI #8162 CABINET DEPTH 41

2' - 3"

2' - 3"

LSI #8120 CABINET DEPTH 31

LSI #8162 CABINET DEPTH 41

24' - 9"

1130A

2' - 3"

LSI LSI #8160 #8160 CABINET DEPTH CABINET DEPTH 31 31

2' - 3"

2' - 3"

2' - 3"

LSI #8160 CABINET DEPTH 31

LSI #8120 CABINET DEPTH 31

LSI #8162 CABINET DEPTH 41

2' - 3"

INSTRUMENT STORAGE

LSI #8160 CABINET DEPTH 31

FILLER

R

2' - 3"

R

LSI #8160 CABINET DEPTH 31

R

2' - 3"

R

U1.1

2' - 3"

2' - 3"

LSI #8160 CABINET DEPTH 31

24' - 9"

R

U1

LSI #8160 CABINET DEPTH 31

2' - 3"

LSI #8160 CABINET DEPTH 31

2' - 3"

LSI #8160 CABINET DEPTH 31

MB-2

LSI #8160 CABINET DEPTH 31

2' - 3"

IT CABINET 16 /A12-17

LSI #8160 CABINET DEPTH 31

2' - 3"

RE: AV EQUIP CABINET 16 /A12-17

2' - 3"

ORCHESTRA 1136

2' - 3"

2' - 0"

U1.1

LSI #8180 CABINET DEPTH 41

2' - 3"

1' - 8"

U1

LSI #8180 CABINET DEPTH 41

2' - 3"

1130A

LSI #8180 CABINET DEPTH 41

2' - 3"

LSI LSI #8180 #8160 CABINET DEPTH CABINET DEPTH 41 31

INSTRUMENT STORAGE

U1.1

SB-1

LSI #8120 CABINET DEPTH 31

LSI #8334 CABINET DEPTH 41

2' - 3"

LSI #8180 CABINET DEPTH 41

2' - 3"

1' - 6" 1' - 6" 1' - 6"

INSTRUMENT STORAGE 1/4" = 1'-0"

LSI #8160 CABINET DEPTH 31

NOTE: CENTER CASEWORK BETWEEN DOORS

2' - 3"

MUSIC STORAGE 1/4" = 1'-0"

R U1

4'-11" TYP.

LSI #8330 CABINET DEPTH 41

2' - 3"

MB-2

LSI #1220 CABINET DEPTH 41

2' - 3"

ORCHESTRA STORAGE 1/4" = 1'-0"

LSI #1220 CABINET DEPTH 41

1' - 6" 1' - 6" 1' - 6"

3/4" SCRIBE

1' - 0" 2' - 10" 2' - 10"

7' - 0"

14

16

17

18

1/4" = 1'-0"

1/4" = 1'-0"

GUITAR STORAGE; RE: 13/A12-17

1138

3

INSTRUMENT STORAGE

7' - 0"

12

FILLER

LSI #8332 DEPTH 41

LSI #8183 DEPTH 41

1' - 2" 1' - 9"

2

INSTRUMENT STORAGE

LSI #8172 DEPTH 41

1' - 9"

LSI #8176 DEPTH 41

1' - 9"

LSI #8186 DEPTH 41

1' - 6"

LSI #8336 DEPTH 41

1136A

LSI #8172 DEPTH 41

1' - 9" 11' - 5"

1' - 9"

LSI #8186 CABINET DEPTH 41

LSI #8186 CABINET DEPTH 41

R

U1.1

R

U1

U1

R U1.1

3/4" SCRIBE

GENERAL NOTES

1

1. VERIFY MOUNTING HEIGHTS AND CLEARANCES AT ALL LOCATIONS; NOTIFY THE ARCHITECT OF ANY DISCREPANCIES WITH THE CONTRACT DRAWINGS

2. FLOOR FINISH, WALL FINISH AND WALL BASE ARE TO BE INSTALLED BENEATH AND BEHIND ALL BASE CABINETS AND/OR EQUIPMENT INDICATED TO BE REMOVABLE.

3. PROVIDE FINISHED END PANELS MATCHING THE CABINET FACE AT ALL EXPOSED CABINET SIDES.

4. ALL EXPOSED EDGES AT COUNTER TOPS ARE TO HAVE EASED EDGE, TYP UON.

5. REFER TO THE TYPICAL MOUNTING HEIGHTS SCHEDULE FOR MOUNTING HEIGHTS OF ACCESSORIES AND DEVICES.

6. REFER TO ROOM FINISH SCHEDULE AND INTERIOR DESIGN DRAWINGS FOR ALL FINISHES THROUGHOUT THE BUILDING.

7. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A PULL PER SPEC.

8. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A LOCK PER SPEC.

9. PROVIDE SCRIBE / FILLER AT INTERSECTION OF WALLS / ADJACENT CASEWORK AS REQUIRED FOR FULL OPERATION

S

R

Q

P

O

N

M

L

K

J

I

H

G

F

E

D

C

B

A

12" x 12" TILE; RE: INTERIOR FINISH PLANS & MATERIAL FINISH SCHEDULE A/13-21

ACOUSTICAL PANELS, RE: MATERIAL FINISH SCHEDULE A/13-21

SIGNAGE

OPEN TO BEYOND

PLASTIC LAMINATE, RE: MATERIAL FINISH SCHEDULE A/13-21

COUNTERTOP BEYOND

FILLER AS NECESSARY

PLUMBING FIXTURE, RE: ARCHITECTURAL SPECIFICATIONS

DISPLAY CASE, RE: ARCHITECTURAL SPECIFICATIONS

INTERIOR WALL TILE, RE: MATERIAL FINISH SCHEDULE A/13-21

PAINT, RE: WALL FINISH PLANS AND/OR WALL FINISH SCHEDULE.

USE SCHLUTER DILEX-AHK-PHK, RE: MATERIAL FINISH SCHEDULE AND/OR FINISH PLANS

USE BULLNOSE EDGE TILE, RE: MATERIAL FINISH SCHEDULE AND/OR FINISH PLANS

MIRROR, RE: ARCHITECTURAL SPECIFICATIONS.

QUARTZ COUNTERTOP, RE: FINISH MATERIAL SCHEDULE, SHEET A/13-21

INTERIOR DOOR AND/OR INTERIOR WINDOW; RE: FLOOR PLANS FOR DESIGNATION & DOOR/WINDOW SCHEDULE FOR SPECIFICATIONS.

CEILING, RE: REFLECTED CEILING PLANS

LIGHT FIXTURE, RE: ELECTRICAL DRAWINGS.

WALL FINISH TO EXTEND BEHIND FIXTURE

WORKING NOTES

T

6" x 6" ACCENT TILE; RE: INTERIOR FINISH PLANS & MATERIAL FINISH SCHEDULE TILE MOSAIC; RE: INTERIOR FINISH PLANS & MATERIAL FINISH SCHEDULE

Z

Y

X

W

V

LOCK AT CABINET/DRAWERS; ALL LOCKS TO BE KEYED ALIKE

GLASS FRONT

CURVED RADIUS COUNTERTOP AND BASE

BASE CABINET W/ DRAWERS

VERTICAL PLASTIC LAMINATE SUPPORT AS REQ'D BY AWI STANDARDS

BASE; RE: INTERIOR FINISH PLANS & MATERIAL FINISH SCHEDULE

U

aa

R

PAINTED GYP. LOW WALL

R

U1

bb

R

U1.1

R

COVE BASE, RE: INT. FINISH PLANS

R

U1

R

cc

U1.1

R

3' - 0"

R

3' - 0"

U1.1

3' - 0"

LSI #3052 CABINET DEPTH 14 1/4

U1

3' - 0"

LSI #3052 CABINET DEPTH 14 1/4

LSI #1136 CABINET DEPTH 24 1/4

LSI #1102 CABINET DEPTH 24 1/4

LSI #1102 CABINET DEPTH 24 1/4

3' - 0"

LSI #1102 CABINET DEPTH 24 1/4

4' - 0"

LSI #6060 CABINET DEPTH 17

TYP OF (12)

2' - 3"

SIM TO LSI # 8162 EXCEPT WALL HUNG

LINE OF STRUCTURAL STEEL BRACED FRAME BEYOND

16' - 0"

3' - 0"

MOBILE INSTRUMENT STORAGE

3' - 0"

1

3' - 0"

LSI #9835

LSI #3052 CABINET DEPTH 14 1/4

U1.1

1130

1130

INSTRUMENTAL

MB-2

INSTRUMENTAL

2

LSI #3002 CABINET DEPTH 14 1/4

U1

1130

INSTRUMENTAL

6" FILLER

UNIFORM STORAGE

LSI #8166 CABINET DEPTH 31

1/4" = 1'-0"

LSI #8162 CABINET DEPTH 31

R

U1

R

11' - 3"

LSI #8162 CABINET DEPTH 31

R

U1.1

R

U1

R

2' - 3"

R

2' - 3"

R

U1.1

2' - 3"

R

U1

U1

R

U1.1

SB-1

R

2' - 3"

1136A

INSTRUMENT STORAGE

7' - 0" 2' - 3"

U1.1

R

U1

IT CABINET 16 /A12-17

2' - 3"

LSI #8166 CABINET DEPTH 41" - TYP OF (5)

U1.1

4'-11" TYP.

RE: AV EQUIP CABINET 16 /A12-17

2' - 0"

LSI #9831

1' - 8"

3' - 8"

INSTRUMENTAL CLASSROOM

INSTRUMENTAL STORAGE

1/4" = 1'-0"

MB-2

INSTRUMENTAL ACOUSTICAL PANELING

U1 4' - 11" TYP

R

UNIFORM STORAGE

1/4" = 1'-0"

INSTRUMENT STORAGE

3/4" SCRIBE

4"

1/4" = 1'-0"

7' - 0"

4' - 9" 1' - 9" 28' - 0"

R

LSI #6060 CABINET DEPTH 17

R

4' - 0"

26

FILLER

3' - 2"

7' - 0" 2' - 3"

13

3

3/4" SCRIBE

7' - 0"

F

E

3/4" SCRIBE

LSI #8162 DEPTH 41

1' - 9"

R

LSI #1102 CABINET DEPTH 24 1/4

U1

3' - 0"

U1.1

LSI #1102 CABINET DEPTH 24 1/4

10' - 0"

3' - 0"

1136

ORCHESTRA

7' - 0" 2' - 3"

33' - 9"

4

4' - 3" TYP 4'-3" TYP.

ORCHESTRA STORAGE 1/4" = 1'-0"

4' - 11" TYP R U1

1136

ORCHESTRA

U1.1

LSI CATALOG 8220 STOR. DEPTH 31

7' - 0"

MUSIC STORAGE 1/4" = 1'-0" 5

2' - 6"

1' - 8"

2' - 10"

R U1

ORCHESTRA STORAGE

LSI CATALOG 8220 STOR. DEPTH 31

1/4" = 1'-0"

LSI CATALOG 8220 STOR. DEPTH 31

2' - 3"

25

4'-3" TYP.

D

40

38

LSI CATALOG 8220 STOR. DEPTH 31

2' - 3"

7' - 0"

4' - 3" TYP

2' - 3" 9' - 0"

6

4' - 0" 3' - 0"

C

B

A

4' - 3" TYP

3' - 2" 7' - 0"

4' - 3" TYP 2' - 3"

1/4" = 1'-0" 7

4' - 0"

3' - 0"

2' - 10"

7' - 0"

ORCHESTRA STORAGE

3/4" SCRIBE

37

7' - 0"

F

E

D

C

B

A

Lantz-Boggio Architects, P.C.

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

Ph: 303.773.0436 | Fax: 303.773.8709

IN ASSOCIATION WITH:

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

NEW LARAMIE HIGH SCHOOL

Laramie | Wyoming

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022

Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

ITEM

1

#

DESCRIPTION

2012.32 15 JANUARY 2014

31 JAN 2014 Addendum No. 1

DATE

ISSUED FOR CONSTRUCTION

ADD

Seal:

Key Plan:

LBA Project Date

INTERIOR ELEVATIONS

A12-13


7

6

5

3' - 0"

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

3

2

1

27' - 3"

10' - 6" 3' - 0"

4

3' - 0"

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

2' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

2' - 0"

3' - 0"

2' - 9"

2' - 6"

KEWAUNEE #W25W241224L CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241224L CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241233 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241230 CABINET DEPTH 12 3/4

1' - 6" KEWAUNEE #W25W241218R CABINET DEPTH 12 3/4

GENERAL NOTES A12-14

Lantz-Boggio Architects, P.C.

1. VERIFY MOUNTING HEIGHTS AND CLEARANCES AT ALL LOCATIONS; NOTIFY THE ARCHITECT OF ANY DISCREPANCIES WITH THE CONTRACT DRAWINGS

3' - 0"

KEWAUNEE KEWAUNEE #A00W0336-00_0 #D81W312218 APRON CABINET DEPTH 22

1' - 6" 1' - 6"

3' - 0"

3' - 6"

1' - 0"

GROMMET

2' - 6"

3' - 6"

2' - 2"

3/4" SCRIBE

3/4" SCRIBE

A12-14

11

KEWAUNEE #E60W362224L CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

DW-1

2' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

2' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362233 CABINET DEPTH 22

3' - 0"

2' - 9"

LSI #1012

LSI #1330

LSI #1490 APRON

LSI #1012

LSI #1012

LSI #1490 APRON

LSI #1330

LSI #1012

LSI #7820 BOOK DROP

RF-1

A12-14

15

2' - 0"

26' - 0"

36

1/4" = 1'-0"

A12-14

5

5' - 7 1/2"

3' - 1 1/2"

6' - 4 7/8"

1' - 6" 1' - 0"

24

1/4" = 1'-0"

MEDIA CENTER DESK

12

1/4" = 1'-0"

NEW LARAMIE HIGH SCHOOL

7. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A PULL PER SPEC. 8. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A LOCK PER SPEC.

3H

R & D PREP INTERIOR ELEVATION

Laramie | Wyoming

9. PROVIDE SCRIBE / FILLER AT INTERSECTION OF WALLS / ADJACENT CASEWORK AS REQUIRED FOR FULL OPERATION

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

MAIL ROOM ENLARGED PLAN 1/4" = 1'-0"

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

6' - 0"

R&D 2054

7' - 0" SD

LSI #3062 CABINET DEPTH 14 1/4

1108 2' - 0 1/4" 1' - 2"

PRINTER NIC

FINISHED END PANEL

GROMMET

MO-1

PTD

SD

LSI #9837

E

DC-3 3' - 0"

3/4" SCRIBE

DC-1 4' - 0"

2' - 10"

RF-1 DC-3 3' - 0"

10' - 0" FILLER

3/4" SCRIBE KEWAUNEE #E41W362233 CABINET DEPTH 22

2' - 9"

KEWAUNEE #E41W362233 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

2' - 9"

3' - 0"

KEWAUNEE #S25W842236 CABINET DEPTH 22

KEWAUNEE #G00W362236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #S25W842236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #S25W842236 CABINET DEPTH 22

3' - 0"

KEWAUNEE #S20W841236 CABINET DEPTH 12 3/4

KEWAUNEE #S20W841236 CABINET DEPTH 12 3/4

KEWAUNEE #S20W841236 CABINET DEPTH 12 3/4

KEWAUNEE #S20W841236 CABINET DEPTH 12 3/4

KEWAUNEE #S20W841236 CABINET DEPTH 12 3/4

KEWAUNEE #S20W841236 CABINET DEPTH 12 3/4

KEWAUNEE #S20W841236 CABINET DEPTH 12 3/4

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

LSI #1002 CABINET DEPTH 24 1/4

LSI #1002 CABINET DEPTH 24 1/4

3' - 0" 3/4" SCRIBE

LSI #1000 CABINET DEPTH 14 1/4

FILLER

LSI #1000 CABINET DEPTH 14 1/4

2' - 6"

3' - 0"

FILLER FINISHED END PANEL

LSI #1102 CABINET DEPTH 24 1/4

LSI #1350 CABINET DEPTH 24 1/4

2' - 9"

2' - 6"

1' - 9"

5' - 0"

6' - 0"

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

3/4" SCRIBE

1108

2' - 10"

PTD

LSI #3502 CABINET DEPTH 14 1/4

7' - 0"

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

2' - 0"

2' - 6"

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

3' - 6"

1' - 8"

KEWAUNEE #W25W241233 CABINET DEPTH 12 3/4

- 3" 1' - 3"

DW-1

LSI #1490 PANEL DEPTH 24 1/4

LSI #1101 CABINET DEPTH 24 1/4

FINISHED END PANEL

3' - 1 1/2"

2' - 10"

3' - 0"

7' - 0"

3' - 0"

WRKRM/ MAIL/ STOR

WRKRM/ MAIL/ STOR

2049E

2' - 9"

LSI #3012 1' CABINET DEPTH 14 1/4 LSI #3022 CABINET DEPTH 14 1/4

2' - 10"

KEWAUNEE #W25W241233 CABINET DEPTH 12 3/4

HALL 2' - 0"

2' - 9"

2' - 2"

7' - 0"

E

8' - 0"

11' - 6"

2' - 0"

30" DEEP EPOXY COUNTER

LSI #3052 CABINET DEPTH 13 1/4

2' - 2"

4" HIGH EPOXY BACKSPLASH

1037

3' - 0"

LSI #3052 CABINET DEPTH 13 1/4

2' - 10"

CORRIDOR

3' - 0"

LSI #1162 CABINET DEPTH 24 1/4

2' - 6"

7' - 7 1/2"

3/4" SCRIBE

3' - 6"

2' - 0"

8' - 0"

8' - 0"

BEAKER DRYING RACK

LSI #3050 CABINET DEPTH 14 1/4

LSI #3062 CABINET DEPTH 14 1/4

1108

40 A12-14

2' - 6" PTD

SD

LSI #9832

2' - 10"

2' - 10"

SD

2064

PTD 7' - 0"

R&D

3/4" SCRIBE FILLER

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #G00W342236 CABINET DEPTH 22

DW-1

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

2' - 0"

KEWAUNEE #E41W362242 CABINET DEPTH 22

KEWAUNEE #E41W362248 CABINET DEPTH 22

3' - 6"

4' - 0"

WRKRM/ MAIL/ STOR

WRKRM/ MAIL/ STOR

MB-1

2101

4" HIGH EPOXY BACKSPLASH

2' - 6"

3' - 6"

LSI #3050 CABINET DEPTH 14 1/4

OFFICE/ WORKROOM

30" DEEP EPOXY COUNTER

HDWD BASE TRIM ON WD BLKG

2' - 0"

2' - 0"

1' - 0"

2' - 0"

3' - 0"

3/4" SCRIBE

LSI #1022 CABINET DEPTH 24 1/4

LSI #1132 CABINET DEPTH 24 1/4

LSI #1012 CABINET DEPTH 24 1/4

2' - 0"

3' - 0"

2' - 0"

FINISHED END PANEL

LSI #1022 CABINET DEPTH 24 1/4

LSI #1002 CABINET DEPTH 24 1/4

1' - 6"

3' - 6"

FILLER

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

UNIFORM STORAGE

1108

1165 7' - 0"

REMOVEABLE PLAM ACCESS PANEL DIE WALL CUTOUT AS REQ'D FOR CABLE MANAGEMENT BASE CABINET BEYOND

1' - 10"

3' - 0"

2' - 2"

6" 4" 2"

1/4" = 1'-0"

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

4' - 2"

4' - 0" KEWAUNEE #W25W301248 CABINET DEPTH 12 3/4

5

1/4" = 1'-0"

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

KITCHENETTE INTERIOR ELEVATION

FINISHED END

D

2' - 10"

3' - 6" KEWAUNEE #W25W301242 CABINET DEPTH 12 3/4

MAIL ROOM INTERIOR ELEVATION

7' - 0"

2' - 0" KEWAUNEE #W25W241224 CABINET DEPTH 12 3/4

11

1/4" = 1'-0"

2' - 10"

3' - 0" KEWAUNEE #W25W151236 CABINET DEPTH 12 3/4

MAIL ROOM INTERIOR ELEVATION

7' - 0"

3' - 0" KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

17

1/4" = 1'-0"

PLAM COUNTERTOP

1' - 0"

PLAM COUNTERTOP BEYOND PLAM PANEL ON 1/2" PLYWD DIE WALL

23

1/4" = 1'-0"

HALL 2049 PRINTER STATION

PLAM PANEL

2' - 10"

D

35

1/4" = 1'-0"

1' - 8"

41

R & D LAB INTERIOR ELEVATION

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

41' - 6"

DISPLAY CASE @ CORRIDOR 1037

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

6. REFER TO ROOM FINISH SCHEDULE AND INTERIOR DESIGN DRAWINGS FOR ALL FINISHES THROUGHOUT THE BUILDING.

24' - 9"

R & D PREP INTERIOR ELEVATION

5. REFER TO THE TYPICAL MOUNTING HEIGHTS SCHEDULE FOR MOUNTING HEIGHTS OF ACCESSORIES AND DEVICES.

16 17

IN ASSOCIATION WITH:

4. ALL EXPOSED EDGES AT COUNTER TOPS ARE TO HAVE EASED EDGE, TYP UON.

1108

+34"

LSI #1012

1' - 7"

7' - 0"

FILLER BLIND CORNER WITH (1) DOOR

LSI #1022 CABINET DEPTH 24 1/4

LSI #1002 CABINET DEPTH 24 1/4

LSI #1002 CABINET DEPTH 24 1/4

LSI #1012 CABINET DEPTH 24 1/4

2' - 0"

3' - 0"

3' - 0"

2' - 0"

5' - 0"

3/4" SCRIBE

LSI #8730 CABINET DEPTH 24 1/4

LSI #8730 CABINET DEPTH 24 1/4

LSI #8730 CABINET DEPTH 24 1/4

LSI #8730 CABINET DEPTH 24 1/4

40 HANGING FOOTBALL JERSEYS

40 HANGING FOOTBALL JERSEYS

40 HANGING FOOTBALL JERSEYS

40 HANGING FOOTBALL JERSEYS

4' - 0"

4' - 0"

4' - 0"

4' - 0"

10' - 0"

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

16' - 0"

7' - 0"

24' - 6"

R&D LAB INTERIOR ELEVATION

22

1/4" = 1'-0"

MEDIA WORK ROOM

16

1/4" = 1'-0" 10' - 6"

LSI SHELF #3150 24" DEEP, 50" HIGH LSI #1520

2' - 10"

1' - 6"

LSI #3050 CABINET DEPTH 14 1/4

LSI #3050 CABINET DEPTH 14 1/4

LSI #3050 CABINET DEPTH 14 1/4

LSI #3062 CABINET DEPTH 14 1/4

3' - 0"

4' - 0"

LSI #1350 CABINET 24 1/4

LSI #1350 CABINET 24 1/4

LSI #1350 CABINET 24 1/4

LSI #1350 CABINET 24 1/4

LSI #1350 CABINET 24 1/4

LSI RE: AV EQUIP #1350 CABINET CABINET 16 /A12-17 24 1/4

1' - 7" 1' - 7" 1' - 7" 1' - 7" 1' - 7" 1' - 7"

LSI #1350 CABINET 24 1/4

IT CABINET 16 /A12-17

1' - 8"

2' - 0"

LSI #1350 CABINET 24 1/4

LSI #1350 CABINET 24 1/4

1' - 7" 1' - 7" 1' - 7"

3/4" SCRIBE

21

1/4" = 1'-0"

LSI #1102 CABINET DEPTH 24 1/4

LSI #1002 CABINET DEPTH 24 1/4

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

KEWAUNEE #W25W301236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241224 CABINET DEPTH 12 3/4

KEWAUNEE #W25W151236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

3' - 0" KEWAUNEE #W25W301236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W301236 CABINET DEPTH 12 3/4

4" HIGH EPOXY BACKSPLASH

4' - 7 1/4"

OFFICE/ WORKROOM

16'-4" RADIUS

EQ

LSI #5000 CABINET DEPTH 24 1/4

2' - 9"

2' - 9"

3' - 1 1/2"

2' - 9"

2' - 6"

2' - 0"

3' - 0"

3' - 0"

KEWAUNEE #W25W301224L CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

3/4" SCRIBE

LSI #1022 CABINET DEPTH 14 1/4

LSI #1002 CABINET DEPTH 14 1/4

2' - 0"

4' - 0"

3' - 0"

3' - 0"

3' - 0"

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

3' - 0"

13' - 0"

7' - 0"

3/4" SCRIBE

LSI #5062 CABINET DEPTH 24 1/4

LSI #5062 CABINET DEPTH 24 1/4

LSI #5062 CABINET DEPTH 24 1/4

3' - 0"

3' - 0"

3' - 0"

3' - 0"

12' - 0"

13' - 10 1/2"

15

SIM TO LSI SIM TO LSI #9520 EXCEPT 36" WIDE #9520 EXCEPT 36" WIDE CABINET DEPTH CABINET DEPTH 14 1/4 14 1/4

MAIL ROOM

9

1/4" = 1'-0"

MAIL ROOM

ITEM

9' - 0"

3

1/4" = 1'-0"

DW-1

3' - 0"

2' - 0"

KEWAUNEE #G00W342236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

KEWAUNEE #E41W362236 CABINET DEPTH 22

3' - 0"

3' - 0"

3' - 0"

3' - 0"

DESCRIPTION

IT TECH INTERIOR ELEVATION B 1/4" = 1'-0"

2' - 9" KEWAUNEE #W25W241230 CABINET DEPTH 12 3/4

12' - 3" 3' - 3"

3' - 0"

3' - 0"

LSI #3050 CABINET DEPTH 13 1/4

3' - 0"

LSI #3050 CABINET DEPTH 13 1/4

LSI #3050 CABINET DEPTH 13 1/4

IT TECH

2064

EXPOSED STRUCTURAL STEEL BRACED FRAME; PAINT

4" HIGH EPOXY BACKSPLASH 30" DEEP EPOXY COUNTER

2' - 0"

2111

R&D

LSI #9837

SCRIBE

LSI LSI #1012 #1001 CABINET DEPTH CABINET DEPTH 24 1/4 24 1/4

2' - 0" FILLER

KEWAUNEE #E40W342218 CABINET DEPTH 22

KEWAUNEE #E41W342236 CABINET DEPTH 22

KEWAUNEE #E41W342236 CABINET DEPTH 22

KEWAUNEE #E41W342236 CABINET DEPTH 22

KEWAUNEE #E41W342236 CABINET DEPTH 22

KEWAUNEE #E41W342236 CABINET DEPTH 22

KEWAUNEE #E41W342230 CABINET DEPTH 22

2' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

2' - 9"

GROMMET

B

Seal:

2' - 10"

KEWAUNEE #E41W362236 CABINET DEPTH 22

DATE

30" DEEP EPOXY COUNTER

SPACE FOR FUTURE FRIDGE

PTD

#

2' - 10"

SD

3/4" SCRIBE

MOBILE UNIT SEE 22 /A12-17

3/4" SCRIBE

MOBILE UNIT SEE 22 /A12-17

MOBILE UNIT SEE 22 /A12-17

LSI #1102 CABINET DEPTH 24 1/4

LSI #1490 PANEL DEPTH 24 1/4

LSI #1330 CABINET DEPTH 24 1/4

2' - 6"

3' - 0"

2' - 0"

2' - 6"

MOBILE UNIT SEE 22 /A12-17

FILLER

12' - 0"

19' - 9"

32

A12-14

2101

LSI #5060 CABINET DEPTH 14 1/4

4' - 6"

LSI #1490

LSI #1012

LSI #5060 CABINET DEPTH 14 1/4

LSI #3050 CABINET DEPTH 13 1/4

17' - 0"

39

LSI #5060 CABINET DEPTH 14 1/4

2' - 6"

BEAKER DRYING RACK

LSI #1012

COPIER (NIC)

LSI #5060 CABINET DEPTH 14 1/4

C

2111

2' - 6"

EMERGENCY EYE WASH

1' - 6"

19' - 9"

3' - 0"

A12-15

LSI #1330

3' - 0"

1/4" = 1'-0"

7' - 0"

LSI #1012

3' - 6"

16

2' - 0"

2' - 10"

2103

3/4" SCRIBE

1' - 8"

2' - 0" 7' - 0"

AV STOR

3' - 0"

FINISHED END

FILLER

LSI #1012 CABINET DEPTH 24 1/4

IT TECH

2058

2' - 2"

FINISHED END PANEL

LSI #1002 CABINET DEPTH 24 1/4

MEDIA WORKROOM

17' - 0"

LSI #9832

1115

EQ FILLER

LSI #1002 CABINET DEPTH 24 1/4

9' - 0"

R&D LAB INTERIOR ELEVATION

R&D

CORRIDOR

7' - 4"

33

1/2" = 1'-0"

A12-17

4" RUBBER BASE

24' - 11"

WORKROOM SEC @ T-TOP

34

EQ 2' - 10"

RE: LAPTOP STORAGE CABINET 18 /A12-17

1/4" = 1'-0"

37 A12-17

SB-1

LSI #1001 CABINET 24 1/4

UNIFORM STORAGE

EQ

2058

FILLER

B

3' - 0"

EQ

1' - 0"

R&D

4

1/4" = 1'-0"

OFFICE/ WORKROOM

HDWD BASE TRIM ON WD BLKG

39

3' - 0"

2101

2' - 6"

C

PLAM COUNTERTOP PLAM PANEL ON 1/2" PLYWD DIE WALL

3' - 0"

A12-17

REMOVEABLE PLAM ACCESS PANEL DATA / POWER DIE WALL CUTOUT AS REQ'D FOR CABLE MANAGEMENT CASEWORK BEYOND

1/4" = 1'-0"

MAIL ROOM INTERIOR ELEVATION

ISSUED FOR CONSTRUCTION

2' - 0"

2' - 0"

LSI #3180 24" DEEP, 50" HIGH

32

10

4' - 6"

2' - 2"

1' - 10"

7' - 0"

6" 4" 2"

GROMMET PLAM COUNTERTOP

3' - 0"

LSI LSI #3082 #3050 CABINET DEPTH CABINET DEPTH 14 1/4 14 1/4 BLIND CORNER

3 1/2" DISPLAY RAIL 2 SLIDING MARKER BOARDS; 1 SLIDING TACK BOARD BEHIND MARKER BOARDS;REFER TO SECTION 32/A12-17

PLAM PANEL

1' - 0"

1' - 6"

MAIL ROOM INTERIOR ELEVATION

7' - 0"

1/2" = 1'-0"

34

2' - 10"

WORKROOM SEC @ CASEWORK BASE

7' - 0"

40

3' - 6"

+42

R&D LAB INTERIOR ELEVATION

20

1/4" = 1'-0"

R & D LAB INTERIOR ELEVATION

2

1/4" = 1'-0"

IT TECH INTERIOR ELEVATION Key Plan:

1/4" = 1'-0"

22' - 6"

24

LSI #1490

22

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 6"

3' - 6"

3' - 0"

3' - 0"

3' - 0"

LSI #6052 CABINET DEPTH 14 1/4

LSI #6052 CABINET DEPTH 14 1/4

LSI #6052 CABINET DEPTH 14 1/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241236 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241242 CABINET DEPTH 12 3/4

KEWAUNEE #W25W241242 CABINET DEPTH 12 3/4

SOFFIT ENCLOSURE PANEL APRON FOR FH-2 CONTROLS

PTD

MB-1

SD

2054 FH-2 2' - 6"

LSI #9837

LSI #5063 CABINET DEPTH 24 1/4

3' - 0"

RF-1 2' - 10"

LSI #1101 CABINET DEPTH 24 1/4

3' - 0"

LSI #1162 CABINET DEPTH 24 1/4

LSI #1101 CABINET DEPTH 24 1/4

3' - 0"

3' - 0"

VENT 40 A12-17

FINISHED END PANEL

14' - 10"

KEWAUNEE #E41W362242 CABINET DEPTH 22

FILLER

WORKROOM ENLARGED PLAN 1/4" = 1'-0" 7

31

NURSE INTERIOR ELEVATION

19

1/4" = 1'-0" 6

SUPPORT BRACKET; TYP AT MOBILE UNITS

5

3' - 6"

MOBILE UNIT SEE 22 /A12-17

MOBILE UNIT SEE 22 /A12-17

MOBILE UNIT SEE 22 /A12-17

MOBILE UNIT SEE 22 /A12-17

3' - 2"

3' - 2"

3' - 2" 22' - 8"

3' - 2"

KEWAUNEE #E41W362242 CABINET DEPTH 22

3' - 0"

2058

KEWAUNEE ACID STORAGE CABINET #G80W362230_019625 CABINET DEPTH 22 TYP OF (2)

KEWAUNEE #E41W362242 CABINET DEPTH 22

5' - 0"

3/4" SCRIBE

A

1

1/4" = 1'-0" 3

3' - 0"

2

1

INTERIOR ELEVATIONS

1' - 6"

R & D LAB INTERIOR ELEVATION 1/4" = 1'-0"

2012.32 15 JANUARY 2014

KEWAUNEE KEWAUNEE #E41W362236 #E40W362218 CABINET DEPTH CABINET DEPTH 22 22

9' - 6"

3' - 6"

R & D LAB INTERIOR ELEVATION 4

30" DEEP EPOXY COUNTER

R&D

4" HIGH EPOXY BACKSPLASH 30" DEEP EPOXY COUNTER

2' - 10"

3/4" SCRIBE

7' - 0"

3' - 6"

LBA Project Date

R&D

2' - 10"

40 A1 2-1 4

7' - 0"

4' - 7 1/4"

LSI #7820 BOOK DROP

1113

2' - 6"

LSI #1012

13' - 0"

FINISHED END PANEL

37

EXHAUST DUCT

NURSE

LSI #1330

A

3' - 6" KEWAUNEE #W25W241242 CABINET DEPTH 12 3/4

+30

1' - 8"

A12-14

9' - 0"

2' - 10"

21

11' - 0"

LSI #1012

1' - 8"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

10

+34"

10' - 7"

42

SD

WRKRM/ MAIL/ STOR

1' - 0"

KEWAUNEE #E41W362236 CABINET DEPTH 22

PTD

6' - 5 1/2"

KEWAUNEE #A00W0336-00_0 APRON

4" HIGH EPOXY BACKSPLASH 30" DEEP EPOXY COUNTER

Ph: 303.773.0436 | Fax: 303.773.8709

3. PROVIDE FINISHED END PANELS MATCHING THE CABINET FACE AT ALL EXPOSED CABINET SIDES.

FINISHED END PANEL

2' - 10"

7' - 0"

7' - 0"

2' - 0" 2' - 6"

7' - 0"

WORK STATIONS WITH EPOXY COUNTER AND BACKSPLASH

2' - 6"

F

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

9H

+34"

1' - 0"

2054A

COUNTER SHUTTER

2101

MB-1

2054A

BEAKER DRYING RACK

2. FLOOR FINISH, WALL FINISH AND WALL BASE ARE TO BE INSTALLED BENEATH AND BEHIND ALL BASE CABINETS AND/OR EQUIPMENT INDICATED TO BE REMOVABLE.

COPIER / PRINTER

R&D PREP

+96"

2' - 0"

R&D PREP

1' - 2"

9

OFFICE/ WORKROOM

A12-14


7

6

5

4

3

2

1

GENERAL NOTES

TACKABLE BACK WALL

3' - 0"

2' - 0"

A12-15

+30

4

5. REFER TO THE TYPICAL MOUNTING HEIGHTS SCHEDULE FOR MOUNTING HEIGHTS OF ACCESSORIES AND DEVICES.

15

NEW LARAMIE HIGH SCHOOL

7. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A PULL PER SPEC.

A12-15

8. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A LOCK PER SPEC.

5 A12-15

Laramie | Wyoming

9. PROVIDE SCRIBE / FILLER AT INTERSECTION OF WALLS / ADJACENT CASEWORK AS REQUIRED FOR FULL OPERATION

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

KIOSK FLOOR PLAN 1/4" = 1'-0"

LAMINATE STONE EDGE TO CONCEAL CTOP SUPPORTS 2' - 10"

HIGH COUNTER BEYOND

2' - 10"

GROMMET

PROVIDE CUTOUTS FOR POWER AND DATA CABLE DISTRIBUTION

DATA / POWER ADJUSTABLE SHELF W/ HARDWOOD NOSING

2' - 6"

6"

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

GROMMET 6" MTL STUD FRAMING WITH GYP BD EACH SIDE DATA / POWER

PLAM FINISHED FACE PANEL

WD BASE CABINET

4X4 HSS POST @ 5'0" O.C. MAX

7"

STL CTOP SUPPORT AT 36" OC MAX, WELD TO 4X4 HSS POST

6" MTL STUD FRAMING WITH GYP BD EACH SIDE 3' - 6"

PLAM FINISHED FACE PANEL

1' - 1"

REVEAL TO MATCH LOWER COUNTER, THICKNESS, & HEIGHT

3' - 6"

1' - 0"

2' - 2"

PROVIDE CUTOUTS FOR POWER AND DATA CABLE DISTRIBUTION

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

2' - 2"

2' - 2"

E

4X4 HSS POST @ 5'0" O.C. MAX

KIOSK SECTION

5

3/4" = 1'-0"

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

KIOSK SECTION 3/4" = 1'-0"

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

2' - 3"

EQ

9"

3' - 4 1/4"

1' - 0"

MONITOR RE: A/V DWGS

1002

D

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

4"

2' - 6"

3' - 6"

8' - 6"

6' - 8"

COMMONS

2' - 6"

1' - 4"

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

3' - 4 1/4"

EQ

1' - 4"

4' - 6"

GYP BD SOFFIT W/ SLOPED FRONT

EQ

1' - 4 1/2"

EQ

FINISHED WOOD TOP

D

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

RUBBER BASE AT TOE KICK

11

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

6. REFER TO ROOM FINISH SCHEDULE AND INTERIOR DESIGN DRAWINGS FOR ALL FINISHES THROUGHOUT THE BUILDING.

+42"

3" 1' - 7 1/8"

16

MEDIA CENTER CUBBY SECTION 1/2" = 1'-0"

10

1' - 7 1/8"

KIOSK DISPLAY

4

1/2" = 1'-0"

KIOSK FRONT ELEVATION 1/4" = 1'-0"

ISSUED FOR CONSTRUCTION 2' - 2" LAMINATE STONE EDGE TO CONCEAL CTOP SUPPORTS

1' - 1 1/4"

7"

5 3/4"

1' - 0"

2' - 0"

PLAM FINISHED FACE PANEL

2' - 6"

C

WD BASE CABINET ADJUSTABLE SHELF W/ HARDWOOD NOSING

3' - 6"

PROVIDE CUTOUTS FOR POWER AND DATA CABLE DISTRIBUTION

6" MTL STUD FRAMING WITH GYP BD EACH SIDE

16

CORRIDOR

A12-15

2001

C

4' - 6"

STL CTOP SUPPORT AT 36" OC MAX, WELD TO 4X4 HSS POST

4X4 HSS POST @ 5'0" O.C. MAX 1' - 0" TYP

RUBBER BASE AT TOE KICK

27' - 0"

ITEM

15

KIOSK SECTION

9

3/4" = 1'-0"

#

DATE

DESCRIPTION

MEDIA CENTER CUBBIES 1/4" = 1'-0"

2' - 0" PLAM CTOP; RETURN TO ALUM WINDOW

POOL CONTROL ROOM

2' - 6"

B

GROMMET AT EACH KNEE SPACE

B

Seal: WALL CLEAT AS REQ'D

1' - 0"

2190

7' - 0"

1" PLAM CROP SUPPORT @ 48" O.C.

LSI #5063 CABINET DEPTH 24 1/4

LSI #5063 CABINET DEPTH 24 1/4

LSI #5063 CABINET DEPTH 24 1/4

LSI #5063 CABINET DEPTH 24 1/4

LSI #5063 CABINET DEPTH 24 1/4

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

15' - 0"

8"

4' - 3" TYP

14

SECTION @ POOL CONTROL COUNTER 1" = 1'-0"

R

R

R

R

R

R

R

R

U1

U1.1

U1

U1.1

U1.1

U1

U1.1

U1

8

POOL CONTROL ROOM INTERIOR ELEVATION Key Plan:

1/4" = 1'-0"

4' - 11" TYP

MB-5

SB-1

POOL CONTROL ROOM

14

2190

A12-15

LBA Project Date

MB-5

A 2' - 6"

A 5' - 1 1/2"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

IN ASSOCIATION WITH:

4. ALL EXPOSED EDGES AT COUNTER TOPS ARE TO HAVE EASED EDGE, TYP UON.

A12-15

TALL CABINET WITH STORAGE DRAWERS UNDER SLIDING GLASS DOORS

E

Ph: 303.773.0436 | Fax: 303.773.8709

3. PROVIDE FINISHED END PANELS MATCHING THE CABINET FACE AT ALL EXPOSED CABINET SIDES.

F

12

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

2. FLOOR FINISH, WALL FINISH AND WALL BASE ARE TO BE INSTALLED BENEATH AND BEHIND ALL BASE CABINETS AND/OR EQUIPMENT INDICATED TO BE REMOVABLE.

11 A12-15

10

Lantz-Boggio Architects, P.C.

1. VERIFY MOUNTING HEIGHTS AND CLEARANCES AT ALL LOCATIONS; NOTIFY THE ARCHITECT OF ANY DISCREPANCIES WITH THE CONTRACT DRAWINGS

6' - 6"

3' - 4 1/4"

6' - 10"

+42"

CHORAL

4' - 0"

1122

RE: AV EQUIP CABINET 16 /A12-17

6' - 0"

1' - 8"

4' - 0"

4' - 0"

4' - 0"

3 3/8"

4' - 0"

4' - 0"

4' - 0"

7

6

7

1/4" = 1'-0" 4

3' - 7"

2' - 0"

CHORAL INTERIOR ELEVATION 5

INTERIOR ELEVATIONS

IT CABINET 16 /A12-17

A12-15

3' - 8"

25

2012.32 15 JANUARY 2014

3

POOL CONTROL ROOM INTERIOR ELEVATION 1/4" = 1'-0" 2

1


7

6

5

4

3

2

1

GENERAL NOTES 1. VERIFY MOUNTING HEIGHTS AND CLEARANCES AT ALL LOCATIONS; NOTIFY THE ARCHITECT OF ANY DISCREPANCIES WITH THE CONTRACT DRAWINGS

Q

1 1/2"

1' - 6" C

MAKEUP

PLAM WORKSURFACE ON SUBSTRATE

EQ.

2' - 4" 7 1/8" 2' - 4"

EQ.

3' - 0"

O

2" 1' - 9" 2"

11"

X

1' - 3"

K

EQ.

3' - 1"

EQ.

24

1/4" = 1'-0"

MAKE UP COUNTER SECTION

18

1" = 1'-0"

MAKE UP WEST

12

1/4" = 1'-0"

MAKE UP NORTH A

WALL FINISH TO EXTEND BEHIND FIXTURE

B

LIGHT FIXTURE, RE: ELECTRICAL DRAWINGS.

C

CEILING, RE: REFLECTED CEILING PLANS

D

INTERIOR DOOR AND/OR INTERIOR WINDOW; RE: FLOOR PLANS FOR DESIGNATION & DOOR/WINDOW SCHEDULE FOR SPECIFICATIONS.

E

QUARTZ COUNTERTOP, RE: FINISH MATERIAL SCHEDULE, SHEET A/13-21

F

MIRROR, RE: ARCHITECTURAL SPECIFICATIONS.

G

USE BULLNOSE EDGE TILE, RE: MATERIAL FINISH SCHEDULE AND/OR FINISH PLANS

H

USE SCHLUTER DILEX-AHK-PHK, RE: MATERIAL FINISH SCHEDULE AND/OR FINISH PLANS

B

I

PAINT, RE: WALL FINISH PLANS AND/OR WALL FINISH SCHEDULE.

F

J

INTERIOR WALL TILE, RE: MATERIAL FINISH SCHEDULE A/13-21

K

DISPLAY CASE, RE: ARCHITECTURAL SPECIFICATIONS

O

L

PLUMBING FIXTURE, RE: ARCHITECTURAL SPECIFICATIONS

W

M

FILLER AS NECESSARY

X

N

COUNTERTOP BEYOND

V

O

PLASTIC LAMINATE, RE: MATERIAL FINISH SCHEDULE A/13-21

P

OPEN TO BEYOND

Q

SIGNAGE

R

ACOUSTICAL PANELS, RE: MATERIAL FINISH SCHEDULE A/13-21

S

12" x 12" TILE; RE: INTERIOR FINISH PLANS & MATERIAL FINISH SCHEDULE A/13-21

T

6" x 6" ACCENT TILE; RE: INTERIOR FINISH PLANS & MATERIAL FINISH SCHEDULE TILE MOSAIC; RE: INTERIOR FINISH PLANS & MATERIAL FINISH SCHEDULE

C

10 3/4" 1" TYP.

EQ

EQ

RECLAIMED WOOD PANELING

O

EQ

SCHLUTER QUADEC

bb

1/2" PLYWOOD NAIL BASE, PAINTED RE: FINISH PLANS

E TYP.

L

1" M 2' - 7"

2' - 6"

2' - 6"

2' - 6"

2' - 6"

2' - 6"

2' - 6"

A12-16

CORRIDOR 1037

1' - 0"

M

23

WOOD BLOCKING

3"

aa TYP. 2' - 6"

RETURN TILE TO INSIDE CORNER @ TYP CORRIDOR HGT

METAL STUD

2' - 10 1/2"

M

RECLAIMED WOOD 3' - 0"

EQ

Q

6"

E

EQ

Q

1' - 5 3/4"

1 1/2" TYP.

2' - 7 1/2"

Q

LSI #1260 CAB DEPTH 18"

ELEVATOR DOOR

12X12 WALL TILE; RE: FINISH PLANS

1' - 3"

LSI #1260 CAB DEPTH 18"

1' - 3"

WALL TILE, RE: FINISH PLANS

EQ.

3' - 1"

EQ.

1' - 3"

BASE TILE, RE: FINISH PLANS 6X6 BASE TILE, RE: FINISH PLANS 6"

SCHLUTER DILEX-AHK/-PHK SCHLUTER DILEX-AHK/-PHK

U

35

CYBER CAFE BACK WALL

23

1/4" = 1'-0"

RECLAIMED WOOD TO WALL TILE

17

1" = 1'-0"

TYP ELEVATOR ENTRANCE 1/4" = 1'-0"

11

V

BASE; RE: INTERIOR FINISH PLANS & MATERIAL FINISH SCHEDULE

1/4" = 1'-0"

W

VERTICAL PLASTIC LAMINATE SUPPORT AS REQ'D BY AWI STANDARDS

X

BASE CABINET W/ DRAWERS

Y

CURVED RADIUS COUNTERTOP AND BASE

Z

GLASS FRONT

aa

LOCK AT CABINET/DRAWERS; ALL LOCKS TO BE KEYED ALIKE

bb

PAINTED GYP. LOW WALL

cc

COVE BASE, RE: INT. FINISH PLANS

1' - 0"

WD BLKG IN WALL

10' - 0"

2' - 10 1/2"

PLUGS TO MATCH RAIL

2' - 0"

2' - 6"

2' - 6"

M

2' - 6"

1-1/2" FABRIC WRAPPED ACOUSTIC PANEL

1' - 0"

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187 Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

MAPLE CHAIR RAIL BASE - MOUNT TO WALL

F 3-SIDED

D

F 3-SIDED

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

O TYP. V TYP.

6" AFF

1' - 2"

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

D

2' - 8 1/4"

aa TYP.

Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

2' - 6"

SOUND WALL FABRIC WRAPPED ACOUSTICAL PANEL

U2

22 A12-16

bb

M

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022

1126

E TYP. K

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

TILE CEILING APC-4

PRACTICE

6' - 0"

6" 1 1/2"

1 1/2" D

2"x6" HARDWOOD RAIL. EASE ALL EDGES WITH 1/4" RADIUS.

T.O. RAIL ELEV = 102'-8"

7"

SOUND BATTS GWB CEILING 3 1/2" METAL STUDS @ 16" OC

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

E

MAKE UP EAST

11K C

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

WORKING NOTES

1/4" = 1'-0"

A12-16 12' - 7"

Laramie | Wyoming

9. PROVIDE SCRIBE / FILLER AT INTERSECTION OF WALLS / ADJACENT CASEWORK AS REQUIRED FOR FULL OPERATION

39

34

CYBER CAFE NORTH

22

1/4" = 1'-0"

x

CHAIR RAIL DETAIL

16

1 1/2" = 1'-0"

PRACTICE ROOM TYPICAL 1/4" = 1'-0"

10

MAKE UP SOUTH 1/4" = 1'-0"

ISSUED FOR CONSTRUCTION

x14 A12-16

1' - 5 1/8"

36

3/4" MDF CHALKBOARD PAINTED PLYBOARD FOR SIGNAGE

S

1' - 9 1/4" 1' - 2 5/8"

2 1/2" TYP.

1' - 0"

39

1' - 0"

D

5' - 3 3/4"

D

D

RETURN TILE TO INSIDE CORNER @ TYP CORRIDOR HGT

D

C SCHLUTER QUADEC RETURN TILE TO INSIDE CORNER AT DOOR RECESS

6X6 BASE TILE, RE: FINISH PLANS

SCHLUTER DILEX HKU

13' - 6 5/8"

1070

6X6 ACCENT TILE, RE: FINISH PLANS 12X12 WALL TILE, RE: FINISH PLANS

L 35

39

A12-16

7' - 1 1/2"

1' - 0"

SCHLUTER DILEX HKU DW-1

ITEM

xAA

#

DATE

DESCRIPTION

PLASTIC LAMINATE SHELF APRON 1' - 0"

11 3/4"

3' - 0" A12-16

RF-2

R 8'-6"

4X12 BULLNOSE EDGE, RE: FINISH PLANS

34

10' - 6"

PLASTIC LAMINATE VERTICAL SUPPORT

CORRIDOR

SCHLUTER QUADEC K TYP.

PLASTIC LAMINATE FIXED SHELVES

C

HM WINDOW AS OCCURS

PAINT RE: FINISH PLAN D TYP.

3' - 0"

BLOCKING AS NEEDED

xBB 9 1/4"

1' - 5 7/8"

1' - 8"

METAL VENEER

2' - 7 1/2"

CYBER CAFE SHELVING DETAIL 3/4" = 1'-0"

33

1' - 0"

ENLARGED CYBER CAFE

21

1/4" = 1'-0"

TYPICAL CORRIDOR RESTROOM ELEVATION

9

1/4" = 1'-0"

TYPICAL WAINSCOT ELEVATION 1/4" = 1'-0"

B

B

Seal:

1 1/2"

Key Plan: SOLID SURFACE CTOP

10"

3"

VERIFY DIMS & LOCATION W/ MANUFACTURER PRIOR TO FABRICATION

5" 1' - 0"

ELECTRIC FANS - RE: A/V DWGS VERIFY DIMS & LOCATION W/ MANUFACTURER PRIOR TO FABRICATION

ACCENT WALL TILE RE: FINISH PLANS 12X12 ACCENT WALL TILE, RE: FINISH PLANS

HARDWOOD RAIL AND STILE OVERLAY DOOR

2' - 0"

4X12 ACCENT TILE, RE: FINISH PLANS

28 1/2"

2' - 0"

FIXED SHELF W/ PROJECTOR MECHANICALLY ATTACHED VERIFY DIMS W/ MANUFACTURER PRIOR TO FABRICATION

LBA Project Date

6X6 ACCENT TILE, RE: FINISH PLANS

7' - 4"

METAL WOVEN MESH EXHAUST AIR OPENING (McNICHOLES CHATEAU 3105 SS-316 OR APP'D EQUAL)

44" A

EQUIPMENT RACK RE: A/V DWGS

LOUVERED VENT VERIFY DIMS & LOCATION W/ MANUFACTURER PRIOR TO FABRICATION

2' - 0"

SIDE

25 7

6

2' - 0"

2012.32 15 JANUARY 2014

INTERIOR ELEVATIONS

6X6 BASE TILE RE: FINISH PLANS

SIDE

SCHLUTER DILEX HKU

FRONT

PROJECTOR CABINET DETAILS

7

1" = 1'-0" 5

A

12X12 WALL TILE, RE: FINISH PLANS

4"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

CYBER CAFE PUBLIC VIEW

NEW LARAMIE HIGH SCHOOL

8. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A LOCK PER SPEC.

3"

36

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

7. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A PULL PER SPEC.

EQ. 5' - 5"

1' - 3"

IN ASSOCIATION WITH:

6. REFER TO ROOM FINISH SCHEDULE AND INTERIOR DESIGN DRAWINGS FOR ALL FINISHES THROUGHOUT THE BUILDING.

V

LSI #1260 CAB DEPTH 18"

EQ.

5. REFER TO THE TYPICAL MOUNTING HEIGHTS SCHEDULE FOR MOUNTING HEIGHTS OF ACCESSORIES AND DEVICES.

O

V LSI #1260 CAB DEPTH 18"

9"

2" 2' - 4"

D

Ph: 303.773.0436 | Fax: 303.773.8709

4. ALL EXPOSED EDGES AT COUNTER TOPS ARE TO HAVE EASED EDGE, TYP UON.

W

D

O

2' - 6"

2' - 10 1/2"

Y

2" 2' - 4"

A12-16

W

Z

2' - 4"

24

2' - 6"

E

1' - 2"

6"

T6 J

3' - 0"

F

PLAM SUPPORT BRACKET

O

3' - 6"

1 1/2"

1 1/2"

F

B

SOLID BLOCKING IN WALL

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

3. PROVIDE FINISHED END PANELS MATCHING THE CABINET FACE AT ALL EXPOSED CABINET SIDES.

F

SPEED BRACING AS NEEDED 9"

2. FLOOR FINISH, WALL FINISH AND WALL BASE ARE TO BE INSTALLED BENEATH AND BEHIND ALL BASE CABINETS AND/OR EQUIPMENT INDICATED TO BE REMOVABLE.

B

1144

Lantz-Boggio Architects, P.C.

4

3

A12-16

TYPICAL FULL HEIGH WAINSCOT 1/4" = 1'-0" 2

1


7

6

5

4

3

2

1

GENERAL NOTES

WOOD PROJECTOR BOX, FINISHED ALL SIDES ADDITIONAL STORAGE SPACE

12 A12-17

3' - 0"

SST ALL EXPOSED SIDES

2' - 10"

1" ADJUSTABLE SHELF W/ 1-1/4" HARDWOOD NOSING, TYP

F 1' - 4"

1' - 9"

INCORPORATE DISPLAY RAIL AT TOP CORNICE TRIM

(15) EQ SPACES

4' - 0 1/2"

IN ASSOCIATION WITH:

4. ALL EXPOSED EDGES AT COUNTER TOPS ARE TO HAVE EASED EDGE, TYP UON.

(2) 8-BAY LAPTOP RECHARGING MODULES #55186 SPECTRUM INDUSTRIES, INC.

3"

Ph: 303.773.0436 | Fax: 303.773.8709

3. PROVIDE FINISHED END PANELS MATCHING THE CABINET FACE AT ALL EXPOSED CABINET SIDES.

5. REFER TO THE TYPICAL MOUNTING HEIGHTS SCHEDULE FOR MOUNTING HEIGHTS OF ACCESSORIES AND DEVICES.

4"

A12-17

WD SHELVING; SEE ELEVATION FOR NUMBER & SPACING OF SHELVES

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

NYLON GUIDES

2' - 0"

37

Lantz-Boggio Architects, P.C.

2. FLOOR FINISH, WALL FINISH AND WALL BASE ARE TO BE INSTALLED BENEATH AND BEHIND ALL BASE CABINETS AND/OR EQUIPMENT INDICATED TO BE REMOVABLE.

3 1/2" HARDWOOD CORNICE

BALL BEARING NYLON ROLLER

SLIDING TACKBOARD

1' - 6"

CLEAR

2' - 6"

1' - 2"

WOOD BOOKSHELF W/ HARDWOOD FACEFRAME ADJ WD SHELF W/ 1 1/4" HARDWOOD NOSING

2' - 8"

11" EACH

T.O. CMU 102'-8"

1. VERIFY MOUNTING HEIGHTS AND CLEARANCES AT ALL LOCATIONS; NOTIFY THE ARCHITECT OF ANY DISCREPANCIES WITH THE CONTRACT DRAWINGS

8 3/4"

TREATED PLYWOOD

1' - 10 1/2"

1' - 10 1/2" CLEAR

CLEAR

CMU JAMB BEYOND COILING DOOR JAMB GUIDE BEYOND SEALANT

1' - 2 1/8" CLEAR

1' - 4"

OVERHEAD PROJECTOR RE: A/V DWGS

1' - 2 1/8"

X 36" LONG

2' - 10"

1' - 0"

6. REFER TO ROOM FINISH SCHEDULE AND INTERIOR DESIGN DRAWINGS FOR ALL FINISHES THROUGHOUT THE BUILDING.

2' - 0"

LSI CATALOG 1001 MOD CABINET DEPTH 24

LSI CATALOG 1001 MOD CABINET DEPTH 24

7. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A PULL PER SPEC.

(2) 8-BAY LAPTOP RECHARGING MODULES #55186 SPECTRUM INDUSTRIES, INC.

NEW LARAMIE HIGH SCHOOL

8. ALL INSTALLED OPERABLE CABINET DOORS AND DRAWERS ARE TO RECEIVE A LOCK PER SPEC.

1' - 1 1/4"

Laramie | Wyoming

9. PROVIDE SCRIBE / FILLER AT INTERSECTION OF WALLS / ADJACENT CASEWORK AS REQUIRED FOR FULL OPERATION

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

HORIZONTAL SLIDING VISUAL DISPLAY BOARDS PLAM-2 COUNTERTOP

3/4" = 1'-0"

18

T.O. TEACHING WALL

12

3/4" = 1'-0"

1 1/2" = 1'-0"

WD BASE CABINET SINK BEYOND 2' - 0" U.N.O.

4"

WD APRON

1" THICK ADJ SHELF W/ 1 1/4" HARDWOOD NOSING

STORAGE CABINET REMOVEABLE ACCESS PANEL ON CONCEALED Z-CLIPS

4"

TOE CLEAR

1" = 1'-0"

MAILBOX SECTION

34

23

1" = 1'-0"

SEWING CABINET SECTION

17

1/2" = 1'-0"

7' - 0" U.N.O.

32

SECTION AT TYPICAL TEACHING WALL

APRON CLEARANCE, KNEE CLEARANCE AND TOE CLEARANCE TO MEET CURRENT ANSI STANDARDS.

TOE CLEAR

SINK CAB W/ OPEN KNEE SPACE ADA CABINET 1" = 1'-0"

EQ

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

EQ

FLOOR LINE

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

EPOXY COUNTER W/ 4" BACKSPLASH

2' - 6"

WALL CABINET 2' - 6 1/2"

14" DEPTH U.N.O. POWER DATA

1' - 2 1/2" 2' - 9" RADIUSED GYP BD WALL SHIM AS REQ'D

4" RUBBER D SWIVEL CASTERS; LOCKABLE

MOBILE LAB CART; RE: 22/A12/17

2' - 10"

FINISHED ENDS

A/V CONTROL PANEL EPOXY TOP WOOD CABINET WITH HARDWOOD SHELF

FIXED HARDWOOD APRON

4"

DRAWER W/ CONCEALED FULL EXTENSION DRAWER GUIDES (BLUM TANDEM 562-H OR APP'D EQUAL)

LINE OF SHELF BELOW

4" BACKSPLASH OR EPOXY AS NOTED

HARDWOOD RAIL AND STILE OVERLAY DOOR

PLAM COUNTERTOP @ OR EPOXY AS NOTED

METAL WOVEN MESH FRONT (McNICHOLES CHATEAU 3105 SS-316 OR APP'D EQUAL)

SIDESPLASH WHERE BACKSPLASH IS NOTED

A/V RACK, VERIFY DIMS W/ MANUF PRIOR TO FABRICATION

3"

SIM TO KEWAUNEE T01W363037R00_0 EXCEPT 2'-9" WIDE & 1'-10 DEEP

ANGLED FILLER PIECE MANUFACTURES STANDARD METAL REINFORCING SUBFRAME

HARDWOOD SHELF W/ CONCEALED FULL EXTENSION DRAWER GUIDES

4" RUBBER CASTERS; LOCKABLE

1" PLAM CTOP SUPPORT W/ ALUM U-CHANNEL NOSING

PLAM COUNTERTOP 3"

PLYWD SUBTOP W/ HDWD EDGE

1' - 2"

4' - 4"

ADJ WOOD SHELVES W/ HDWD EDGES

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

A/V INPUTS

2' - 2"

FINISHED WOOD TOP, BACK & BOTTOM

LINE OF RADIUSED CTOP ABOVE

EQ 1' - 8"

42

MOBILE BOOKSHELF

33

1/2" = 1'-0"

SECTION @ RADIUSED SHELF

40

1" = 1'-0"

CTOP SUPPORT DETAIL

22

1" = 1'-0"

MOBILE CASEWORK UNIT

16

3/4" = 1'-0"

D

EQ

2' - 0"

BASE CABINET

AV EQUIPMENT CABINET - ELEV. DETAIL

24" DEPTH U.N.O.

1" = 1'-0"

ISSUED FOR CONSTRUCTION

1/4" SEALANT W/ BACKER ROD 3' - 0"

A12-17

EPOXY RESIN TOP AND BACKSPLASH

WOOD BOOKSHELF W/ HARDWOOD FACEFRAME

2' - 10"

UTILITY CHASE

2 SLIDING MARKER BOARDS; 1 SLIDING TACK BOARD BEHIND MARKER BOARDS;REFER TO SECTION 32/A12-17

WOOD CABINET BAY

3' - 1"

1' - 0"

4"

1' - 1 1/4"

INTEGRAL EPOXY RESIN SINK BOWL

ADJ WD SHELF W/ 1 1/4" HARDWOOD NOSING

WD BASE CABINET

GYP BD ON 3 5/8" MTL STUD FRAMING, FULL WIDTH OF CLASSROOM

RUBBER BASE AT TOE KICK 4"

FACE OF WALL

4"

LSI #3180 24" DEEP, 50" HIGH

2' - 4 1/2"

3 1/2" DISPLAY RAIL

1" SOLID SURFACE CTOP ON 3/4" PLYWD SUBTOP, EXTEND TO WINDOW FRAME

FALSE DRAWER FRONT W/ POWER AND DATA

UNISTRUT AS REQ'D FOR UTILITY ROUGH-IN

LSI #1520

32

4" 1 1/2"

LSI SHELF #3150 24" DEEP, 50" HIGH

C

1' - 4"

WD BLKG AS REQ'D TO SUPPORT CTOP

3 5/8" MTL STUD BOX BEAM SPANNING WIDTH OF WINDOW

PROVIDE RACEWAY BEYOND AS REQ'D FOR POWER AND DATA CABLING

2' - 6"

5 1/8"

1' - 8 3/8"

3"

7 1/2"

2' - 4 1/2"

21 SB-1

PRINTER NIC

37

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

4"

1 1/2"

2' - 10" U.N.O.

1' - 2 1/2"

4' - 0"

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

3/4" MDF COUNTER SUPPORT AND PLAM-1 CLOSURE PANEL BEYOND 9"

2' - 4"

E

24" DEPTH U.N.O.

1' - 4"

1' - 2"

EQ

2' - 6" TYP

4"

4"

1' - 2"

1/4" WOOD TRIM 2X4 WD BLOCKING

EQ

KNEE CLEAR 2' - 10" U.N.O.

8"

SPACE FOR 2 SEWING MACHINES, STACKED (14"h X 13"w X 17"d)

RUBBER BASE AT TOE KICK

7' - 0"

LAVATORY BOWL SECURED AS REQUIRED TO UNDERSIDE OF VANITY TOP

PROVIDE RACEWAY AS REQ'D FOR POWER CABLING

E

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

3' - 4"

ADJ WD SHELVING

1' - 4"

2' - 10 1/2"

(4) EQ SPACES

WD BASE CABINET RE: INTERIOR ELEVATIONS

7'-0" UNO

1 1/2"

ADJUSTABLE SHELF W/ HARDWOOD NOSING 1" ADJUSTABLE SHELF W/ 1-1/4" HARDWOOD NOSING, TYP

2' - 0"

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

BACKSPLASH AS NOTED

PLAM CTOP

PLAM CTOP

1' - 9 1/2"

CASEWORK TYPICAL DIMENSIONS AND MOUNTING HEIGHTS

7' - 0"

(4) EQ SPACES

7' - 4"

24

LAPTOP STORAGE/ RECHARGING CAB.

9"

CASEWORK SECTION

2' - 10"

3/4" HIGH DENSITY PARTICLEBOARD WITH PLAM SURFACE TO MATCH MAPLE CABINET

3

3/4" = 1'-0"

C

LEVEL 2 F.F.E. 114'-8"

NOTE: MTL STUD FRAMING, CASEWORK AND COUNTERTOP TO BE INDEPENDENT OF ALUM CURTAINWALL ASSY

2 1/2"

ITEM

#

ADD

1

DATE

DESCRIPTION

31 JAN 2014 Addendum No. 1

LEVEL 02 BOOKCASE @ WINDOW 3/4" = 1'-0"

37

A12-17

SEALANT W/ BACKER ROD

A12-17

7' - 0"

3 5/8" MTL STUD BOX BEAM SPANNING WIDTH OF WINDOW ALUM WINDOW ASSY SOLID SURFACE SILL

1" SOLID SURFACE CTOP ON 3/4" PLYWD SUBTOP

2' - 6"

1' - 7"

1' - 7"

RE: LAPTOP STORAGE CABINET 18 /A12-17

1' - 7"

4' - 0"

LSI #1350 CABINET 24

1' - 7"

LSI #1350 CABINET 24

1' - 7"

LSI #1350 CABINET 24

LSI #1350 CABINET 24

1' - 7"

1' - 7"

LSI #1350 CABINET 24

1' - 7"

RE: AV EQUIP CABINET 16 /A12-17

IT CABINET 16 /A12-17

1' - 8"

2' - 0"

LSI #1012 CABINET 24

2' - 3"

LSI #1350 CABINET 24

1' - 7"

LSI #1350 CABINET 24

1 1/2"

UTILITY CHASE

3' - 1"

ADJ WD SHELF W/ 1 1/4" HARDWOOD NOSING

FILLER

1' - 7"

25' - 10"

RUBBER BASE AT TOE KICK

B

Seal:

LEVEL 2 F.F.E. 114'-8"

4"

FACE OF WALL

GYP BD ON 3 5/8" MTL STUD FRAMING, FULL WIDTH OF CLASSROOM 4"

LSI #1350 CABINET 24

LSI #1350 CABINET 24

SLIP-CLIP CONNECTION TO EXTERIOR WALL FRAMING

ADJUSTABLE SHELF W/ HARDWOOD NOSING

2' - 10"

LSI #1350 CABINET 24

2' - 4 1/2"

B

WD BASE CABINET

UNISTRUT AS REQ'D FOR UTILITY ROUGH-IN

2' - 10"

3/4" SCRIBE

WOOD BOOKSHELF W/ HARDWOOD FACEFRAME; FINISHED BACK AND SIDES

EPOXY RESIN TOP AND BACKSPLASH

4"

WD BLKG AS REQ'D TO SUPPORT CTOP

1' - 1 1/4"

5 1/8"

1' - 8 3/8"

3"

9"

NOTE: MTL STUD FRAMING, CASEWORK AND COUNTERTOP TO BE INDEPENDENT OF EXTERIOR WALL ASSY

2' - 4 1/2"

20

1/2" = 1'-0"

CASEWORK SECTION

2

3/4" = 1'-0"

LEVEL 02 BOOKCASE @ WALL Key Plan:

3/4" = 1'-0"

4"

38

TYPICAL TEACHING WALL ELEVATION

SECTION VIEW SEALANT AS REQ'D

(3) TRACKS ON BOTTOM GUIDE CHANNEL; RE: SECTION

(2) SLIDING MARKER BOARDS

MAX 6'-0" SB-1

4"

VARIES; RE: INTERIOR ELEVATION UTILITY CHASE *

MAX 6'-0" WALL CONDITION VARIES, RE: PLAN

FACE OF WALL

3 1/2" 1/2"

1' - 8 3/8"

2 5/8" 1 3/8"

R1

/4"

3/8"

2"

3/4" 3/4" 5 1/2"

A

6 3/4"

6 3/4"

6 3/4"

2012.32 15 JANUARY 2014

CASEWORK DETAILS

5 1/2"

1 1/4" TYP

4"

5 1/8"

LBA Project Date

ADJ WD SHELF W/ 1 1/4" HARDWOOD NOSING

RUBBER BASE AT TOE KICK

PROJECTOR

LINE OF PRINTER CABINET COUNTERTOP BELOW

10"

ADJUSTABLE SHELF W/ HARDWOOD NOSING

WOOD BOOKSHELF W/ HARDWOOD FACEFRAME

3' - 0"

VARIES; RE: INTERIOR ELEVATION

RE: SPEC (1) SLIDING TACK BOARD

WD BASE CABINET

UNISTRUT AS REQ'D FOR UTILITY ROUGH-IN

6' - 4"

MAX 6'-0"

1' - 4 1/2"

4"

1 1/8"

MAX 6'-0"

VARIES; RE: INTERIOR ELEVATION

LINE EACH CUT OUT WITH FELT

2' - 10"

1 1/8"

(CASEWORK BELOW; RE: INTERIOR ELEVATIONS)

EPOXY RESIN TOP AND BACKSPLASH

2' - 4 1/2"

2' - 0"

CAVITY

VARIES; RE: INTERIOR ELEVATION A

2' - 6" WD BLKG AS REQ'D TO SUPPORT CTOP

1" SOLID SURFACE CTOP ON 3/4" PLYWD SUBTOP, EXTEND TO WINDOW FRAME

1' - 7 1/8" F.V.

3' - 5"

VARIES; RE: INTERIOR ELEVATION

/4"

1 1/8"

BACK BOARD 3/4" PLYWD INTERMITTENT SUPPORT; SPACED AT 36" MAX O.C.

R3

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

BOTTOM GUIDE CHANNEL

CASEWORK @ COUNTER SHUTTER

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

3"

3"

2' - 4 1/2"

PLAN VIEW

* NOTE: UTILITY CHASE TO BE PROVIDED REGARDLESS IF ROUGH-IN IS PRESENT OR NOT

37

SECTION AT TEACHING WALL; TYP

19

1/2" = 1'-0" 7

6

5

CASEWORK SECTION 3/4" = 1'-0" 4

13

GUITAR STORAGE RACK

1

1 1/2" = 1'-0" 3

2

LEVEL 01 BOOKCASE @ WINDOW 3/4" = 1'-0" 1

A12-17


7

6

5

4

3

2

1

Lantz-Boggio Architects, P.C. TAG #

ASVCT CPT1 CPT2 CPT3 CPT4 CPT5 CPT6 CPT7 CR1 E

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

F

HSC ISC LT P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 PL1 QTZ1 RAF RB1 RBT RWD SC SSC E

D

DESCRIPTION

ANTI-STATIC (STATIC DISSIPATIVE) VCT

MANUFACTURER/VENDOR

JOHNSONITE, INC. TANDUS FLOORING TANDUS FLOORING TANDUS FLOORING TANDUS FLOORING TANDUS FLOORING TANDUS FLOORING TANDUS FLOORING DUPONT CAPCO TILE & STONE

DYNEX NYLON CARPET; POWERBOND DYNEX SD NYLON CARPET; POWERBOND DYNEX SD NYLON CARPET; MODULAR TILE CORIAN SOLID SURFACE GLAED PORCELAIN FLOOR AND WALL TILE

INTEGRAL COLOR POLISHED CONCRETE - SEE ARCHITECTURAL SPECIFICATIONS LANDING MAT GENERAL WALL PAINT CEILING PAINT ACCENT WALL PAINT ACCENT WALL PAINT ACCENT WALL PAINT ACCENT WALL PAINT ACCENT WALL PAINT ACCENT WALL PAINT ACCENT WALL PAINT DOOR TRIM PAINT ACCENT WALL PAINT CEILING CLOUD PAINT BACK OF HOUSE & DUCTWORK PAINT PLASTIC LAMINATE QUARTZ RESILIENT ATHLETIC FLOORING - SEE ARCHITECTURAL SPECIFICATIONS RUBBER BASE - SEE ARCHITECTURAL SPECIFICATIONS

JOHNSONITE, INC. SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS NEVAMAR PENTAL QUARTZ/CAPCO TILE & STONE

ITEM #

N/A N/A N/A N/A N/A N/A N/A N/A N/A SGASI12

N/A SW6140 SW7005 SW7612 SW6668 SW6416 SW6027 SW0023 SW6664 SW6005 SW7083 SW2808 SW0038 SW6991 N/A BQ9340P

PATTERN/STYLE

GRANIT SD

Ph: 303.773.0436 | Fax: 303.773.8709

COLOR(S)/FINISH

714 MISTY

FORWARD MOTION 03853

TIDAL ACTION 31709

SIZE/DIMENSIONS

GREEN SUBMARINE 48009

6' ROLL

RIVET 04219

PEACE FROG 54218

24" X 24" TILE

CORIAN ARKE

BEIGE FIELDSTONE SILK/ SEMI MATTE FINISH

47 BROWN MODERATE WHITE PURE WHITE MOUNTAIN STREAM SUNRISE SASSY GREEN CORDOVAN PEWTER TANKARD MARIGOLD FOLKSTONE DARKROOM ROOKWOOD DARK BROWN LIBRARY PEWTER BLACK MAGIC CK2003T/TEXTURED GARNET/POLISHED

FIRE RATING

24" X 24" TILE 6' ROLL 6' ROLL

COLORED PENCIL 02443

HRT HAMMERED N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A CASA ARENA N/A

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

FLOOR TRANSITION MATRIX

FINISH MATERIAL SCHEDULE NOTES

TRANSITION

COLOR

FLOOR TO FLOOOR MATERIAL

JOHNSONITE SLT-XX-A

TBD

RBT to WOM; CPT to VCT; WOM to VCT; WOM to SV; SV to CPT; RBT to CPT

JOHNSONITE SLT-XX-B

TBD

VCT to RBT

JOHNSONITE RRS-XX-C

TBD

VCT to HSC; VCT to SC; VCT to ISC; SV to SC; SV to WD

SCHLUTER-SCHIENE

TBD

CPT to T; VCT to E; SV to E

SCHLUTER-RENO U

TBD

VCT to T; SV to T

SCHLUTER-RENO V

TBD

SSC to T

NEW LARAMIE HIGH SCHOOL

FLOAT FLOOR

N/A

SV to VCT

Laramie | Wyoming

N/A

N/A

WD to SC (SLAB IS DEPRESSED)

IN ASSOCIATION WITH:

WELDROD 1287415

ALL WINDOW SILLS 3/8" GROUT; GROUT COLOR; CUSTOM; #59 SADDLE BROWN

12" X 12" TILE

24" X 24"; 1/8" THICK N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 1 1/4" SLAB

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

GENERAL PAINT & DUCTWORK IN GYM CEILING & DUCTWORK IN WRESTLING, R&D, & POOL

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

ALL DOOR TRIM THEATER WALL PAINT CEILING CLOUDS IN THEATER BACK OF HOUSE IN THEATER & DUCTWORK COUNTERTOP, RE: INTERIOR ELEVATIONS COUNTERTOP, RE: INTERIOR ELEVATIONS

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

RECLAIMED WOOD - SEE ARCHITECTURAL SPECIFICATIONS

SV1 SV2 SV3 SV4 SV5 SV6 SV7 SWV T1

SLIP-RESISTANT, TINTED SEALED CONCRETE - SEE ARCHITECTURAL SPECIFICATIONS RESILIENT HOMOGENEOUS VINYL SHEET FLOORING RESILIENT HOMOGENEOUS VINYL SHEET FLOORING RESILIENT HOMOGENEOUS VINYL SHEET FLOORING RESILIENT HOMOGENEOUS VINYL SHEET FLOORING RESILIENT HOMOGENEOUS VINYL SHEET FLOORING RESILIENT HOMOGENEOUS VINYL SHEET FLOORING RESILIENT HOMOGENEOUS VINYL SHEET FLOORING SIMULATED WOOD VINYL GENERAL GLAZED PORCELAIN FLOOR AND WALL TILE

JOHNSONITE, INC. JOHNSONITE, INC. JOHNSONITE, INC. JOHNSONITE, INC. JOHNSONITE, INC. JOHNSONITE, INC. JOHNSONITE, INC. JOHNSONITE, INC. CAPCO TILE & STONE

T1.1 T2 T3

GLAZED PORCELAIN BULLNOSE UNGLAZED PORCELAIN FLOOR TILE ACCENT GLAZED PORCELAIN FLOOR AND WALL TILE

T3.1 T4 T4.1 T5 T5.1 T6 T6.1 T7 T7.1 T7.2 T8 T8.1 T9 T10 T10.1 T11 T11.1 T12 T13 T14 T15 T16 T16.2 T17 T17.2 TR1 U1 U2 VCT1 VCT2 VCT3 VCT4 VCT5 VCT6 VCT7 WD WOM

GLAZED PORCELAIN BULLNOSE ACCENT GLAZED PORCELAIN WALL TILE GLAZED PORCELAIN BULLNOSE ACCENT GLAZED PORCELAIN WALL TILE GLAZED PORCELAIN BULLNOSE ACCENT GLAZED PORCELAIN WALL TILE GLAZED PORCELAIN MOUNTED BULLNOSE ACCENT GLAZED PORCELAIN WALL TILE GLAZED PORCELAIN BULLNOSE GLAZED PORCELAIN WALL TILE ACCENT GLAZED PORCELAIN WALL TILE GLAZED PORCELAIN BULLNOSE ACCENT GLAZED PORCELAIN MOSAIC WALL TILE ACCENT GLAZED PORCELAIN WALL TILE GLAZED PORCELAIN BULLNOSE TILE STAIR TREAD TILE STAIR TREAD ACCENT STRIP ACCENT GLAZED PORCELAIN WALL TILE ACCENT GLAZED PORCELAIN WALL TILE ACCENT GLAZED PORCELAIN WALL TILE ACCENT GLAZED PORCELAIN WALL TILE ACCENT GLAZED PORCELAIN WALL TILE GLAZED PORCELAIN COVE BASE ACCENT GLAZED PORCELAIN WALL TILE GLAZED PORCELAIN COVE BASE FLOOR TO WALL TRANSITION UPHOLSTERY, VERTICAL APPLICATION - SEE ARCHITECTURAL SPECIFICATIONS UPHOLSTERY, VERTICAL APPLICATION - SEE ARCHITECTURAL SPECIFICATIONS AZROCK VINYL COMPOSITION TILE AZROCK VINYL COMPOSITION TILE AZROCK VINYL COMPOSITION TILE AZROCK VINYL COMPOSITION TILE AZROCK VINYL COMPOSITION TILE AZROCK VINYL COMPOSITION TILE WOOD - SEE ARCHITECTURAL SPECIFICATIONS TDX NYLON WALK-OFF MAT; HYBRID RESILIENT

N/A N/A N/A N/A N/A N/A N/A N/A SGASI12

OPTIMA TILE OPTIMA TILE OPTIMA TILE OPTIMA TILE OPTIMA TILE OPTIMA TILE OPTIMA TILE FPO512648 ARKE

821 FROTHY LATTE 867 TOMATO PASTE 877 OYSTER SHELL 826 GOLDENROD 833 JUNIPER 870 CARMINE 897 SLATE WG CRAFT MAPLE SILK/ SEMI MATTE FINISH

6'-6" SHEET 6'-6" SHEET 6'-6" SHEET 6'-6" SHEET 6'-6" SHEET 6'-6" SHEET 6'-6" SHEET 6" X 48" PLANK; 20 MIL WEAR LAYER 12" X 12" TILE

CAPCO TILE & STONE SGASI12E US CERAMIC TILE/CAPCO TILE & STONE UC DMU2 782 CAPCO TILE & STONE DM KD213

ARKE CC PORCELAIN KHADI

SILK/SEMI MATTE FINISH SAND BEIGE/RUSTIC FINISH

3.25" X 12" 12" X 12" MOSAIC 13.25" X 13.25" TILE

CAPCO TILE & STONE CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS CAPCO TILE & STONE CROSSVILLE/DESIGN MATIERALS CROSSVILLE/DESIGN MATIERALS CHROMTECH/CAPCO TILE & STONE CHROMTECH/CAPCO TILE & STONE CROSSVILLE/DESIGN MATIERALS CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS CROSSVILLE/DESIGN MATERIALS SCHLUTER SYSTEMS ARCHITEX ARCHITEX JOHNSONITE, INC. JOHNSONITE, INC. JOHNSONITE, INC. JOHNSONITE, INC. JOHNSONITE, INC. JOHNSONITE, INC. JOHNSONITE, INC.

DM KD213E A1409 A1409 A1405 A1405 A1120 A1120 A1417 A1417 A1417 A1413 A1413 SG AGR17MSC A1410 A1410 715877 715878 A1405 A1409 A1413 A1417 A1120 A1120 A1409 A1409 DILEX HKU N/A N/A V-210 V-2607 V-248 V-261 V-2614 V-276

KHADI ARGENT ARGENT ARGENT ARGENT COLOR BLOX COLOR BLOX ARGENT ARGENT ARGENT ARGENT ARGENT N/A ARGENT ARGENT POINT POINT ARGENT ARGENT ARGENT ARGENT COLOR BLOX COLOR BLOX COLOR BLOX COLOR BLOX N/A FIBONACCI WAISTCOAT N/A N/A N/A N/A N/A N/A N/A

BEIGE/RUSTIC FINISH LEMON DROP/UPS FINISH LEMON DROP/UPS FINISH HOLLYWOOD AND VINE/UPS FINISH HOLLYWOOD AND VINE/UPS FINISH GRAPE JELLY/UPS FINISH GRAPE JELLY/UPS FINISH CLEAN SLATE/UPS FINISH CLEAN SLATE/UPS FINISH CLEAN SLATE/UPS FINISH UNDER THE SEA/UPS FINISH UNDER THE SEA/UPS FINISH GRAY/SEMI MATTE FINISH ORANGE CRUSH/UPS FINISH ORANGE CRUSH/UPS FINISH WARM 3.0 WARM 4.0 HOLLYWOOD AND VINE/UPS FINISH LEMON DROP/UPS FINISH UNDER THE SEA/UPS FINISH CLEAN SLATE/UPS FINISH GRAPE JELLY/UPS FINISH GRAPE JELLY/UPS FINISH LEMON DROP/UPS FINISH LEMON DROP/UPS FINISH TUSCAN BEIGE MOREL CLOUD OATS PECAN PIE RIPTIDE LEMONADE GRANNY SMITH BERRY RED

3.25" X 13.25" 6" X 6" TILE 4" X 12" BULLNOSE EDGE 6" X 6" TILE 4" X 12" BULLNOSE EDGE 6" X 6" TILE 3" X 3" 6" X 6" TILE 4" X 12" BULLNOSE EDGE 6" X 12" COVE BASE 6" X 6" TILE 4" X 12" BULLNOSE EDGE 12" 6" X 6" TILE 4" X 12" BULLNOSE EDGE 30CM X 60CM 30CM X 60CM 12" X 12" TILE 12" X 12" TILE 12" X 12" TILE 12" X 12" TILE 12" X 12" TILE 6" X 12" COVE BASE 6" X 24" TILE 6" X 12" COVE BASE 3/8" RADIUS 55"W, 63" V REPEAT, 55"H REPEAT 54"W 12" X 12"; 1/8 THICK 12" X 12"; 1/8 THICK 12" X 12"; 1/8 THICK 12" X 12"; 1/8 THICK 12" X 12"; 1/8 THICK 12" X 12"; 1/8 THICK 12" X 12"; 1/8 THICK

TANDUS FLOORING

N/A

ABRASIVE ACTION II 02578

ASPHALT 19102

6' ROLL

E

ASTM E 648 ASTM E 648 ASTM E 648 ASTM E 648 ASTM E 648 ASTM E 648 ASTM E 648

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

3/8" GROUT; GROUT COLOR; CUSTOM; #59 SADDLE BROWN 3/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ SCRIM SHEET 3/8" GROUT; GROUT COLOR; CUSTOM; #59 SADDLE BROWN 3/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978 Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187 Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT 1/8" GROUT 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ 1/8" GROUT; GROUT COLOR; CUSTOM; #101 QUARTZ

D

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

CAL TB 117, UFAC Class 1, ASTM E-84 (unadhered) 72% POLYESTER, 28% TREVIRA CS CAL TB 117, UFAC Class 1, NFPA 260 82% POLYESTER, 18% ACRYLIC ASTM E 648 ASTM E 648 ASTM E 648 ASTM E 648 ASTM E 648 ASTM E 648 ASTM E 648

ISSUED FOR CONSTRUCTION

C

C

ITEM

B

#

DATE

DESCRIPTION

B

Seal:

Key Plan:

LBA Project Date A

A

2012.32 15 JANUARY 2014

FINISH MATERIAL SCHEDULE

A13-21 7

6

5

4

3

2

1


7

6

5

FINISH PLAN GENERAL NOTES:

F

FLOOR FINISH LEGEND:

DESIGN DRAWINGS ONLY. CONTRACTOR TO VERIFY ALL APPROPRIATE INSTALLATION AND CONSTRUCTINO DETAILS AND ABILITY TO INSTALL PER DESIGN INTENT. PLEASE VERIFY ANY QUESTIONS AND/OR DESCREPANCIES WITH LBA INTERIORS PRIOR TO CONSTRUCTION.

2.

CARPET INSTALLATION SHALL COMPLY WITH THE WORKMANSHIP GUIDELINES AS PUBLISHED BY THE AMERICAN CARPET INSTITUTES LATEST EDITION AND SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, PROVIDING AN ATTRACTIVE WRINKLE FREE APPEARANCE. CARPET SEAMS SHALL BE BUTT MATCHED RUNNING IN THE SAME DIRECTION. PROVIDE SEAMING DIAGRAM FOR APPROVAL BY LBA INTERIORS.

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

CPT

CPT

3. 4.

FLASH-PATCH / FLOOR STONE ALL AREAS WHERE FLOOR IS NOT LEVEL OR TRUE PRIOR TO FLOORING INSTALLATION. GENERAL CONTRACTOR TO SCRAPE EXISTING SLAB FREE OF SCREWS, ADHESIVE AND OTHER MISCELLANEOUS MATERIALS FOR A SMOOTH EVEN FINISH.

WOM

WALK-OFF MAT

5.

RUBBER BASE

6.

ALL CARPET TO CARPET AND CARPET TO TILE TRANSITIONS ARE TO BE LEVEL W/SEAMS TIGHTLY BUTTED. FLOAT FLOOR OR PROVIDE UNDERLAYMENT AS NECESSARY ; RE: INTERIOR FINISH SPECS. CENTER FLOORING TRANSITIONS UNDER DOOR UNLESS OTHERWISE POSTED.

RB

7.

ALL ROOMS TO BE PAINTED P1 UNLESS NOTED OTHERWISE

8. 9. 10. 11.

ALL WALL OR CEILING GRILLS, GRATES, ACCESS PANELS TO RECIEVE THE WALL FINISH DIRECLTY ADJACENT. FOR WALLS, IF THE FINISH IS WALL VINYL, PLEASE PAINT TO MATCH WALL VINYL: INTERIOR DESIGNER TO SELECT COLOR. ALL ELECTRICAL SWITCH AND PLUG PLATES FINISHES TO BE DETERMINED; G.C. TO PROVIDE ALL COLOR OPTIONS TO LBA INTERIORS FOR FINAL COLOR SELECTION CORNER GUARDS ON OUTSIDE CORNERS IN PUBLIC AREAS, UNLESS OTHERWISE NOTED. RE: INTERIOR FINISH SCHEDULE FOR CORNER GUARD TO MATCH PAINT SELECTION. ALL ROOMS W/FRP TO BE FULL HEIGHT UNLESS OTHERWISE NOTED

12. 13.

F1

FLOOR FINISH DESIGNATION

X

SEALED CONCRETE

SC

HARDENED SEALED CONCRETE

ISC

INTEGRAL COLOR SEALED CONCRETE

SSC

SLIP RESISTANT, TINTED SEALED CONCRETE

ALL GYP. CEILINGS TO BE P2, UNLESS OTHERWISE NOTED

RBT

RUBBER TREAD

ALL RUBBER BASE TO BE RB1, UNLESS OTHERWISE NOTED

LT

LANDING TREAD

E

EPOXY

SV

FLOOR TO FLOOOR MATERIAL

JOHNSONITE SLT-XX-A

TBD

RBT to WOM; CPT to VCT; WOM to VCT; WOM to SV; SV to CPT; RBT to CPT

JOHNSONITE SLT-XX-B

TBD

VCT to RBT

WOOD

RT

RUBBER TILE

VCT to HSC; VCT to SC; VCT to ISC; SV to SC; SV to WD

JOHNSONITE EG-XX-H

TBD

ALL CONCRETE to CPT

SCHLUTER-SCHIENE

TBD

CPT to T; VCT to E; SV to E

SCHLUTER-RENO U

TBD

VCT to T; SV to T

SCHLUTER-RENO V

TBD

SSC to T

SCHUTER-HKU

TBD

WT to SV

FLOAT FLOOR

N/A

SV to VCT

N/A

N/A

WD to SC (SLAB IS DEPRESSED)

CPT 4 P1, RB1 - SIDE WALLS P5, RB5 - TEACHING WALL F10 T3 (WALL & FLOOR) T3.1 P9, RB9 - BACK WALL TR1 P1 CPT 4 P1 - SIDE WALLS F11 T3 (WALL & FLOOR) P9 - BACK WALL T3.1 P7 - TEACHING WALL TR1 RB1 T5 T9 T1 (WALL) P1 T1.1 TR1 F12 T3 (WALL & FLOOR) SSC (FLOOR) T3.1 TR1 WOM T4 T1 T9 TR1 P1 T6 T6.1 P1

F5

F6

RECLAIMED WOOD PLANKS

RWD

JOHNSONITE RRS-XX-C TBD

F3

ANTI STATIC VCT

WD

WALL FINISH LEGEND:

Lantz-Boggio Architects, P.C.

F15 T3 (WALL & FLOOR) T3.1 TR1 T8 T9 P1

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111 Ph: 303.773.0436 | Fax: 303.773.8709 IN ASSOCIATION WITH:

F21 T1 TR1 T6 T6.1

NEW LARAMIE HIGH SCHOOL

F22 T1 TR1 T8 T 8.1

F16 SC RB1 P1 FRP FROM FINISHED FLOOR 48" ON (2) WET WALLS

Laramie | Wyoming

FINISH MATERIAL ABOVE FINISH MATERIAL BELOW

X

SINGLE FULL HEIGHT WALL FINISH MATERIAL

1

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

F23 T1 TR1 T7 T 7.1

F17 EPOXY INTEGRAL BASE P1

T1 F18 TR1 T5 T5.1

F24 T3 (WALL & FLOOR) T3.1 TR1

9.3

7

8

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

5.2

ADD ALTERNATE - EPOXY Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

RECLAIMED WOOD PLANKS

RWD

E

P

PAINT

T

TILE

U

UPHOLSTERY, VERTICAL APPLICATION

STV

P1 F18

P

STONE VENEER

VCT5

E

SCIENCE 1052

CORNER GUARD

P5

P1 F18

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

P5

1053 P1 F18

ISC

Q

RWD 17 P5

A12-16

STORAGE

ELEVATOR

12

10.8

1054A

ISC

CPT1

12.8

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

OFFICE

1054B

EL-01

ISC

P1 F18

P5

R

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

MACH.ROOM 1056 P1 F18

VESTIBULE

xH

MEN'S TOILET

D

F11

1055

T

P5

1055A

F24

JAN

F16

1057

P1

D

P1 F18

VCT1

1054

21

DATA

1081

1059

F3

P5

1079

CLASSROOM

P9

F11

1061

1083

TYP.

SC ISC

VESTIBULE F24

GUIDANCE 1085

xJ

WAITING

SP ED OFFICE

1085A

1087

ELEC

P1

1063

1071

CLASSROOM 1077

SC

CPT4

U

P1 F18

CORRIDOR

CORRIDOR

CPT5

1069

CPT4

1067

CPT4

ISSUED FOR CONSTRUCTION

P5

P5

CORRIDOR

xJ.5

x4.1

P1 F18

SC CPT4

P5

5

1061A

CPT4

P5

A12-16

WOMEN'S TOILET

CLASSROOM

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

2D ART

T12

CLASSROOM

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

ISC

P1 F18

SCIENCE

14x15.3

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

ADD ALTERNATE OPTIONS:

X X

1

T1 F13 T3 (WALL & FLOOR) F19 TR1 TR1 T4 T3.1 T4.1 T6 T7 (FLOOR & WALL) T9 T7.1 P1 T7.2 P1 F14 T3 (WALL & FLOOR) F20 T1 TR1 TR1 T3.1 T10 T2 (FLOOR) T7 T10.1 T1 (WALL) T9 TR1 P1 T1.1

CPT 2 P1, RB1 - SIDE WALLS P3, RB3 - BACK WALL P9, RB9 - TEACHING WALL F9

F4

SHEET VINYL

AS VCT

COLOR

2

VCT 1 RB1 P1

F2

VINYL COMPOSITION TILE

VCT

HSC

TRANSITION

CPT 2 F7 P1, RB1 - SIDE WALLS P3, RB3 - TEACHING WALL P9, RB9 - BACK WALL F8

TILE

T

3

FINISH GROUP LEGEND:

1.

FLOOR TRANSITION MATRIX

P5

CORRIDOR

VCT5

P5

1072

CPT4 P5

C

STORAGE

STADIUM SEATING

1074A

1074

DISTRIBUTED MEDIA/ LEARNING STREET

1076

CORRIDOR

CLOSET24 1093B

P5

AP SEC'Y

RBT 1058A

FLOAT CARPET AS REQUIRED TO PROVIDE FLUSH TRANSITION AT BYPASS DOOR SILL - TYP.

1093A A08-22

DESIGN LAB

PRODUCTION LAB

HSC

1060

1058

P1 F18

30

C

1060B

1065

HSC

CPT4

F8

W

CORRIDOR

CPT4

ITEM

#

DATE

DESCRIPTION

1070 P1 F18

CPT4

CPT4

STAIRS TO BE RUBBER TREAD LANDING TO BE LANDING TREAD WALK-OFF MAT BELOW

TOOL STORAGE

STORAGE

TLT

CPT5

1073

P5

A12-16

9

36 CPT4

1078

CPT7

CPT5 P5

ASSISTANT PRINCIPAL

F7

CPT4

F7

xL

CPT4

1065A

DISTRIBUTED MEDIA / LEARNING STREET P5

CPT4

1089

1091

xK

V

STORAGE

SMALL GROUP

3' - 0"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

4

1060A VCT5

WORKROOM/ PLANNING/ STORAGE

RBT

OFFICE

F7

HSC P1 F18

1093

VCT1

CORRIDOR

VCT1

1075

P5

P5

P5

WOM

SPECIAL ED CLASSROOM

LT

1068 P5

1082

STV

RBT

xM

F7

B

STV

X

P5

CORRIDOR

CLASSROOM

STORAGE

1084

1090A

P5 P5

QUIET ROOM

P5

B

1090B

CLASSROOM

STV

VCT5

P5

F7

1086

TOILET

F7

CLASSROOM

QUIET ROOM

1094

1088

1092B F8

F7

STORAGE

1062A

P1 F18

HSC

VCT1

1092A

F7

VCT1

Y

LIFE SKILLS CLASS

PRODUCTION LAB

1090

x15.3

TOOL STORAGE

P5

x15

Seal:

OFFICE

P1 F18

SPECIAL ED

F7

1062B

HSC

1092

VESTIBULE

x14.1

DESIGN LAB

1066

F7

1062

Key Plan: E

F

D

C

1064 F6

x13

G HSC

CPT4

B

x12 A

x11 LBA Project Date

x9.1 A

A

x7.3

7

8

1

6.2

5.2

5

x4.1

FIRST LEVEL FINISH PLAN - AREA A

NORTH

A13-21A

FIRST LEVEL FINISH PLAN - AREA A 1/8" = 1'-0" 7

2012.32 15 JANUARY 2014

6

5

4

3

2

1


7

6

5

4

T16

3

2

1

SV1

Lantz-Boggio Architects, P.C. 5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

AA.1

A

SV1

SV1 SV1

CORRIDOR

SV1

1002A F

Ph: 303.773.0436 | Fax: 303.773.8709

AA.1 A

P6

P6

IN ASSOCIATION WITH:

SV2

SV2

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

SV5 SV1

B

x x14 SV1

SV1 SV5

8

SV7 SV3 SV2

NEW LARAMIE HIGH SCHOOL

VESTIBULE

7

1000

SV1

Laramie | Wyoming

F6

T11 T11.1

SV4

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

P6

9.5

SV3 NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

SV5 SV3 SV4

SV1

8.5

SV1

P6

SV1

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

SV7

P1 F21

xCC

SV1

x8

P6 F21

CULINARY ARTS

xBB

SV3

x7

xAA

P6

1041

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

CPT2

SV1

DESIGN LAB

P1 F21

1039

SV1

E

x6

SV7

CORRIDOR

SV4

x5

P1 F21

1003

E

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022

SV5

D

P6

F17

HEALTH/ LIFE-LONG LEARNING

P4

P1

x3

LIFE-LONG LEARNING

1011

1013 VCT1

E

OFFICE 1039A

VCT5

P1 F19

CPT2

x1

1015

CLASSROOM

F1

1017

P9

1041A

STORAGE

CUBBIES F17

STORAGE

VCT1

1039B

1041C

1041B

P4

P4

VCT5

STV

SPECIAL ED CLASS

P4

F17

CPT3

STV

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

xA

1021

VCT4

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

bb

STV

CLASSROOM 1019

VCT4

F7

F17

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

TYP.

P1 F19 P4

LAUNDRY

x2

CLASSROOM

VCT4

VCT7

Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

x4

P1

VCT4 VCT1

VCT1

F7

VCT7

RBT

F

P4

CORRIDOR

P4

STAIR

1031

VCT1

LT

P4

P4

HSC

ST-01.1

D

D VCT4

VCT4

WORKROOM/ PLANNING/ STORAGE

VCT7

RBT CPT2

P1 F19

1043A HSC

RBT

P1 F19

P4

CPT2

VCT5

1033

PRODUCTION LAB

T8

TOOL STORAGE STORAGE

DESIGN LAB

1043B HSC

CONFERENCE/ ITINERANT

1047

CPT2

1038

CPT2

CPT2

P4

F7 CPT3

ISSUED FOR CONSTRUCTION

xD

CPT2

1012

STORAGE F7

1029A

CPT3

SMALL GROUP

VCT4

1027

CPT7

1010B

1045

HSC

STORAGE

xC

1029

CLOSET

1010A

STADIUM SEATING

DISTRIBUTED MEDIA / LEARNING STREET

1025

CPT2

TLT

1043

DISTRIBUTED MEDIA/ LEARNING STREET

CPT2

CORRIDOR

G

WOM

P4

1010

OFFICE

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

1014

CLASSROOM

CPT2

1026

H P4

CORRIDOR VCT1

1035 P4

xE

CPT2

P4

P1 F19

J C

P4

C

STAIR SC

P4

P4 P1 F19

P4

ST-03.1

ELEC

SP ED OFFICE

GUIDANCE

1040

1016

1018

F16

CPT2

CPT2

xF

VCT5

CLASSROOM

CLASSROOM

CLASSROOM

1020

1022

1024

VESTIBULE 3D ART

F24

F12

1049

ITEM

WOMEN'S TOILET

1042A

#

DATE

DESCRIPTION

1042

DATA

ISC T13 A12-16 21

SC

1044

JAN VCT1

1046

F16

P1 F19

VESTIBULE 1048A

K

MEN'S TOILET

F12

1048

xG

F24

K.6 4

P1 F19

3

FINISH PLAN GENERAL NOTES:

B

STORAGE

KILN

STORAGE

1049C

1049B

1049A

ISC

ISC

ISC

SCIENCE 1050

M

P1 F18

ISC

P5

SCIENCE VCT5

1051

FLOOR FINISH LEGEND:

1.

DESIGN DRAWINGS ONLY. CONTRACTOR TO VERIFY ALL APPROPRIATE INSTALLATION AND CONSTRUCTINO DETAILS AND ABILITY TO INSTALL PER DESIGN INTENT. PLEASE VERIFY ANY QUESTIONS AND/OR DESCREPANCIES WITH LBA INTERIORS PRIOR TO CONSTRUCTION.

2.

CARPET INSTALLATION SHALL COMPLY WITH THE WORKMANSHIP GUIDELINES AS PUBLISHED BY THE AMERICAN CARPET INSTITUTES LATEST EDITION AND SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, PROVIDING AN ATTRACTIVE WRINKLE FREE APPEARANCE. CARPET SEAMS SHALL BE BUTT MATCHED RUNNING IN THE SAME DIRECTION. PROVIDE SEAMING DIAGRAM FOR APPROVAL BY LBA INTERIORS.

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

CPT

CPT

3. 4.

FLASH-PATCH / FLOOR STONE ALL AREAS WHERE FLOOR IS NOT LEVEL OR TRUE PRIOR TO FLOORING INSTALLATION. GENERAL CONTRACTOR TO SCRAPE EXISTING SLAB FREE OF SCREWS, ADHESIVE AND OTHER MISCELLANEOUS MATERIALS FOR A SMOOTH EVEN FINISH.

WOM

WALK-OFF MAT

5.

RB

RUBBER BASE

6.

ALL CARPET TO CARPET AND CARPET TO TILE TRANSITIONS ARE TO BE LEVEL W/SEAMS TIGHTLY BUTTED. FLOAT FLOOR OR PROVIDE UNDERLAYMENT AS NECESSARY ; RE: INTERIOR FINISH SPECS. CENTER FLOORING TRANSITIONS UNDER DOOR UNLESS OTHERWISE POSTED.

7.

ALL ROOMS TO BE PAINTED P1 UNLESS NOTED OTHERWISE

8.

ALL WALL OR CEILING GRILLS, GRATES, ACCESS PANELS TO RECIEVE THE WALL FINISH DIRECLTY ADJACENT. FOR WALLS, IF THE FINISH IS WALL VINYL, PLEASE PAINT TO MATCH WALL VINYL: INTERIOR DESIGNER TO SELECT COLOR. ALL ELECTRICAL SWITCH AND PLUG PLATES FINISHES TO BE DETERMINED; G.C. TO PROVIDE ALL COLOR OPTIONS TO LBA INTERIORS FOR FINAL COLOR SELECTION CORNER GUARDS ON OUTSIDE CORNERS IN PUBLIC AREAS, UNLESS OTHERWISE NOTED. RE: INTERIOR FINISH SCHEDULE FOR CORNER GUARD TO MATCH PAINT SELECTION. ALL ROOMS W/FRP TO BE FULL HEIGHT UNLESS OTHERWISE NOTED

9. 10. 11.

VCT1

N 1050A

ISC

1037

N.2 P5 P5

N.5

ISC

PREP 1051A

SC

SEALED CONCRETE

HSC

HARDENED SEALED CONCRETE

ISC

INTEGRAL COLOR SEALED CONCRETE

SSC

SLIP RESISTANT, TINTED SEALED CONCRETE RUBBER TREAD

ALL RUBBER BASE TO BE RB1, UNLESS OTHERWISE NOTED

LT

LANDING TREAD

E

EPOXY

COLOR

FLOOR TO FLOOOR MATERIAL

JOHNSONITE SLT-XX-A

TBD

RBT to WOM; CPT to VCT; WOM to VCT; WOM to SV; SV to CPT; RBT to CPT

JOHNSONITE SLT-XX-B

TBD

VCT to RBT

AS VCT WD

PREP

CORRIDOR

VINYL COMPOSITION TILE

13.

TRANSITION

JOHNSONITE RRS-XX-C TBD

VCT to HSC; VCT to SC; VCT to ISC; SV to SC; SV to WD

JOHNSONITE EG-XX-H

TBD

ALL CONCRETE to CPT

SCHLUTER-SCHIENE

TBD

CPT to T; VCT to E; SV to E

SCHLUTER-RENO U

TBD

VCT to T; SV to T

SCHLUTER-RENO V

TBD

SSC to T

SCHUTER-HKU

TBD

WT to SV

FLOAT FLOOR

N/A

SV to VCT

N/A

N/A

WD to SC (SLAB IS DEPRESSED)

RT RWD

CPT 2 P1, RB1 - SIDE WALLS P3, RB3 - BACK WALL P9, RB9 - TEACHING WALL F9

F3

CPT 4 P1, RB1 - SIDE WALLS P5, RB5 - TEACHING WALL F10 T3 (WALL & FLOOR) T3.1 P9, RB9 - BACK WALL TR1 P1 CPT 4 P1 - SIDE WALLS F11 T3 (WALL & FLOOR) P9 - BACK WALL T3.1 P7 - TEACHING WALL TR1 RB1 T5 T9 T1 (WALL) P1 T1.1 TR1 F12 T3 (WALL & FLOOR) SSC (FLOOR) T3.1 TR1 WOM T4 T1 T9 TR1 P1 T6 T6.1 P1

F4

ANTI STATIC VCT WOOD F6

RUBBER TILE RECLAIMED WOOD PLANKS

X X

FINISH MATERIAL ABOVE FINISH MATERIAL BELOW

X

SINGLE FULL HEIGHT WALL FINISH MATERIAL

T1 F13 T3 (WALL & FLOOR) F19 TR1 TR1 T4 T3.1 T4.1 T6 T7 (FLOOR & WALL) T9 T7.1 P1 T7.2 P1 F14 T3 (WALL & FLOOR) F20 T1 TR1 TR1 T3.1 T10 T2 (FLOOR) T7 T10.1 T1 (WALL) T9 TR1 P1 T1.1 VCT 1 RB1 P1

F2

F5

SHEET VINYL

WALL FINISH LEGEND:

F15 T3 (WALL & FLOOR) T3.1 TR1 T8 T9 P1

F21 T1 TR1 T6 T6.1 F22 T1 TR1 T8 T 8.1

Key Plan:

F16 SC RB1 P1 FRP FROM FINISHED FLOOR 48" ON (2) WET WALLS F17 EPOXY INTEGRAL BASE P1

T1 F18 TR1 T5 T5.1

P1 F18

8

7

5.2

F23 T1 TR1 T7 T 7.1

PAINT

T

TILE

U

UPHOLSTERY, VERTICAL APPLICATION

4

3

D

F24 T3 (WALL & FLOOR) T3.1 TR1

A

LBA Project Date

2012.32 15 JANUARY 2014

FIRST LEVEL FINISH PLAN - AREA B

NORTH

STONE VENEER

A13-21B

1/8" = 1'-0" 5

F

B

ADD ALTERNATE - EPOXY

CORNER GUARD

FIRST LEVEL FLOOR FINISH PLAN - AREA B

E

RECLAIMED WOOD PLANKS

P

STV

G

C

A

P1 F18

6

Seal:

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

ISC

P

7

B

ADD ALTERNATE OPTIONS: 1

RWD

1

F1

CPT 2 F7 P1, RB1 - SIDE WALLS P3, RB3 - TEACHING WALL P9, RB9 - BACK WALL F8

VCT

SV

FINISH GROUP LEGEND:

TILE

ALL GYP. CEILINGS TO BE P2, UNLESS OTHERWISE NOTED

PREP

P1 F18

T

FLOOR FINISH DESIGNATION

12.

FLOOR TRANSITION MATRIX

P1 F18

X

RBT

P5 ISC

1

P5

L

A

2

2

1


7

6

5

4

3

2

1

Lantz-Boggio Architects, P.C. SS

7

8

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

6.3

Ph: 303.773.0436 | Fax: 303.773.8709

FINISH PLAN GENERAL NOTES: 1.

DESIGN DRAWINGS ONLY. CONTRACTOR TO VERIFY ALL APPROPRIATE INSTALLATION AND CONSTRUCTION DETAILS AND ABILITY TO INSTALL PER DESIGN INTENT. PLEASE VERIFY ANY QUESTIONS AND/OR DESCREPANCIES WITH LBA INTERIORS PRIOR TO CONSTRUCTION

2.

CARPET INSTALLATION SHALL COMPLY WITH THE WORKMANSHIP GUIDELINES AS PUBLISHED BY THE AMERICAN CARPET INSTITUTES LATEST EDITION AND SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, PROVIDING AN ATTRACTIVE WRINKLE FREE APPEARANCE. CARPET SEAMS SHALL BE BUTT MATCHED RUNNING IN THE SAME DIRECTION. PROVIDE SEAMING DIAGRAM FOR APPROVAL BY LBA INTERIORS

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

F 3. 4.

FLASH-PATCH / FLOOR STONE ALL AREAS WHERE FLOOR IS NOT LEVEL OR TRUE PRIOR TO FLOORING INSTALLATION GENERAL CONTRACTOR TO SCRAPE EXISTING SLAB FREE OF SCREWS, ADHESIVE AND OTHER MISCELLANEOUS MATERIALS FOR A SMOOTH EVEN FINISH

5. 6.

ALL CARPET TO CARPET AND CARPET TO TILE TRANSITIONS ARE TO BE LEVEL W/SEAMS TIGHTLY BUTTED. FLOAT FLOOR OR PROVIDE UNDERLAYMENT AS NECESSARY ; RE: ARCHITECTURAL FINISH SPECS CENTER FLOORING TRANSITIONS UNDER DOOR UNLESS OTHERWISE POSTED

7.

ALL ROOMS TO BE PAINTED P1 UNLESS NOTED OTHERWISE

8.

ALL WALL OR CEILING GRILLS, GRATES, ACCESS PANELS TO RECEIVE THE WALL FINISH DIRECLTY ADJACENT

9.

ALL ELECTRICAL SWITCH AND PLUG PLATES FINISHES TO BE DETERMINED; G.C. TO PROVIDE ALL COLOR OPTIONS TO LBA INTERIORS FOR FINAL COLOR SELECTION

10.

CORNER GUARDS ON OUTSIDE CORNERS IN PUBLIC AREAS, UNLESS OTHERWISE NOTED. RE: INTERIOR FINISH SCHEDULE FOR CORNER GUARD TO MATCH PAINT SELECTION

11.

ALL ROOMS W/FRP TO BE FULL HEIGHT UNLESS OTHERWISE NOTED

12.

ALL GYP. CEILINGS TO BE P2, UNLESS OTHERWISE NOTED

13.

ALL RUBBER BASE TO BE RB1 UNLESS OTHERWISE NOTED

FLOOR FINISH LEGEND:

x9

X

FLOOR FINISH DESIGNATION

F1

CPT

CPT

WOM

WALK-OFF MAT

RB

RUBBER BASE

ORCHESTRA INSTRUMENT STORAGE

CPT1

T

U1 U1.1

xEE

CPT1

E

FLAT STORAGE 1150A

STAGE CRAFT

TOILET

TOILET

1148A

1146A

F8

F8

DRESSING

1148

1146

F7

HSC

HARDENED SEALED CONCRETE

ISC

INTEGRAL COLOR SEALED CONCRETE

SSC

SLIP RESISTANT, TINTED SEALED CONCRETE

RBT

RUBBER TREAD

LT

LANDING TREAD

E

EPOXY

AS VCT

RT

RUBBER TILE

U1

RWD

U2

1150

F6

RECLAIMED WOOD PLANKS

WALL FINISH LEGEND:

1132

F7

F4

ANTI STATIC VCT

CPT1

PRACTICE

1138

F3

F5

SHEET VINYL

WOOD

U1.1

CPT1 SC

SEALED CONCRETE

WD

CPT1

INSTRUMENT STORAGE

TILE

SC

1134 P8

DRESSING

PP

1130

ENSEMBLE

F2

VINYL COMPOSITION TILE

SV

INSTRUMENTAL

F8

VCT

1136A

CPT1

CPT 2 F7 P1, RB1 - SIDE WALLS P3, RB3 - TEACHING WALL P9, RB9 - BACK WALL

X X

FINISH MATERIAL ABOVE FINISH MATERIAL BELOW

X

SINGLE FULL HEIGHT WALL FINISH MATERIAL

CPT 2 P1, RB1 - SIDE WALLS P3, RB3 - BACK WALL P9, RB9 - TEACHING WALL F9

VCT 1 RB1 P1 T7 (FLOOR & WALL) T7.1 T7.2 P1 T2 (FLOOR) T1 (WALL) TR1 T1.1

CPT 4 P1, RB1 - SIDE WALLS P5, RB5 - TEACHING WALL F10 T3 (WALL & FLOOR) T3.1 P9, RB9 - BACK WALL TR1 P1 CPT 4 P1 - SIDE WALLS F11 T3 (WALL & FLOOR) P9 - BACK WALL T3.1 P7 - TEACHING WALL TR1 RB1 T5 T9 T1 (WALL) P1 T1.1 TR1 F12 T3 (WALL & FLOOR) SSC (FLOOR) T3.1 TR1 WOM T4 T1 T9 TR1 P1 T6 T6.1 P1

NEW LARAMIE HIGH SCHOOL Laramie | Wyoming Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

T1 F13 T3 (WALL & FLOOR) F19 TR1 TR1 T4 T3.1 T4.1 T6 T9 P1

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

F14 T3 (WALL & FLOOR) F20 T1 TR1 TR1 T3.1 T10 T7 T10.1 T9 P1 F15 T3 (WALL & FLOOR) T3.1 TR1 T8 T9 P1

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

F21 T1 TR1 T6 T6.1

F22 T1 TR1 SC F16 T8 RB1 T 8.1 P1 FRP FROM FINISHED FLOOR 48" ON (2) WET WALLS F17 EPOXY INTEGRAL BASE P1

T1 F18 TR1 T5 T5.1

E

F23 T1 TR1 T7 T 7.1 F24 T3 (WALL & FLOOR) T3.1 TR1

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

ADD ALTERNATE - EPOXY

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

FLOOR TRANSITION MATRIX

OFFICE/ MUSIC LIBRARY

COSTUME/ PROP STORAGE

MAKEUP 1144

MM.9

1140

1142

MM.6

P8

SC

VCT1

STORAGE

CPT1

INSTRUMENT STORAGE

CPT1

1128

CPT1

VCT1

P7

P7

CORRIDOR

P8

1133

D

P8

LL

COLOR

FLOOR TO FLOOOR MATERIAL

JOHNSONITE SLT-XX-A

TBD

RBT to WOM; CPT to VCT; WOM to VCT; WOM to SV; SV to CPT; RBT to CPT

JOHNSONITE SLT-XX-B

TBD

VCT to RBT VCT to HSC; VCT to SC; VCT to ISC; SV to SC; SV to WD

JOHNSONITE EG-XX-H

TBD

ALL CONCRETE to CPT

RECLAIMED WOOD PLANKS

SCHLUTER-SCHIENE

TBD

CPT to T; VCT to E; SV to E

P

PAINT

SCHLUTER-RENO U

TBD

VCT to T; SV to T

T

TILE

SCHLUTER-RENO V

TBD

SSC to T

U

UPHOLSTERY, VERTICAL APPLICATION

SCHUTER-HKU

TBD

WT to SV

STONE VENEER

FLOAT FLOOR

N/A

SV to VCT

CORNER GUARD

N/A

N/A

WD to SC (SLAB IS DEPRESSED)

RWD

VCT1

P8

TRANSITION

JOHNSONITE RRS-XX-C TBD

1130A

MM VCT1

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION:

STV

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

ADD ALTERNATE OPTIONS: 1

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

FINISH GROUP LEGEND:

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

1136

IN ASSOCIATION WITH:

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

D

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

T1 T10

CORRIDOR

PRACTICE

CORRIDOR

1139

1126

1137

CHORAL 1122

CPT1 VCT2

U2

CPT1

STAGE

U1

JJ.7

KK

U1.1

PRACTICE

ISSUED FOR CONSTRUCTION

1124 CPT1

VCT7

U2 VCT1

PIANO STOR

STAIR

SC

ST-09.1

P8 P8

LIFT

HH.3

STAIR

STAIR

P8

ST-07.1

SC

ST-08.1

LIFT-01

HH

C

x9.3

1131A

SC

HH.3

x9.2

HH VCT1 SC

P1 F20

VCT2

C

CORRIDOR VCT1

1119

VCT1

GG.3

SRO

P1 F20

TOILET

COTS

1114

1113A

1116 F8 SC

VAULT CPT1

ITEM

NURSE VCT2

VCT2

#

DATE

DESCRIPTION

1113

1110A

HH.4 AD/AP SEC'Y BOOKEEPER

1112

1110

TOILET

FF

1111

CPT1 CPT1

AD/AP OFFICE

T8

VCT2

1109

CORRIDOR 1115

CPT1

THEATER

EE

REFER TO TH SERIES DRAWINGS FOR FINISHES AT THEATER CPT1

T1 T10

WRKRM/ MAIL/ STOR

CONF 1107

1108 CPT1

VCT7

B

B

P8

DD

CPT1

Seal:

P8 SV2

P7

ELEC

CONTROL

A12-16

7

CAFETERIA STORAGE

SECRETARY

PRINCIPAL

1106

1105

1118

1153

1129A

P7

ATTENDANCE

CPT1

CPT1

CPT1

SC

1157

DATA

BB.5

RECORDS STORAGE

SV1

1151

SC

REGISTRAR

CPT1

1103

1104

Key Plan:

CPT1

JAN 1149

RWD P8

F7 A12-16

10 T17

T16 SV7

FAMILY TOILET

VEST

1155

1127

A

ELEVATOR EL-02

17 CPT1

COATS

MEN'S TOILET WOMEN'S TOILET

F13

1123

SC

RECEPTION 1102

SUB SECRETARY

CORRIDOR

MACH RM

A

CPT1

1120

LBA Project Date

CPT1

1100 A

SV1

AA.1

P6

P6 SV1

D

1101

CPT1

1145

SC

F13

F

B

WAITING

1129

E C

SV1

VEST

P6

F8

P1 F20

T1 T10

1147

1125

A

BB

SV2

SV1

G

A

SV1

AA.1

2012.32 15 JANUARY 2014

FIRST LEVEL FINISH PLAN - AREA C

9 11.6

11

1 7

6

7

8

NORTH

6

A13-21C

FIRST LEVEL FLOOR FINISH PLAN - AREA C 1/8" = 1'-0" 5

4

3

2

1


7

6

5

4

3

2

1

Lantz-Boggio Architects, P.C. 5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111 Ph: 303.773.0436 | Fax: 303.773.8709 IN ASSOCIATION WITH:

FINISH PLAN GENERAL NOTES: 1.

DESIGN DRAWINGS ONLY. CONTRACTOR TO VERIFY ALL APPROPRIATE INSTALLATION AND CONSTRUCTION DETAILS AND ABILITY TO INSTALL PER DESIGN INTENT. PLEASE VERIFY ANY QUESTIONS AND/OR DESCREPANCIES WITH LBA INTERIORS PRIOR TO CONSTRUCTION

2.

CARPET INSTALLATION SHALL COMPLY WITH THE WORKMANSHIP GUIDELINES AS PUBLISHED BY THE AMERICAN CARPET INSTITUTES LATEST EDITION AND SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, PROVIDING AN ATTRACTIVE WRINKLE FREE APPEARANCE. CARPET SEAMS SHALL BE BUTT MATCHED RUNNING IN THE SAME DIRECTION. PROVIDE SEAMING DIAGRAM FOR APPROVAL BY LBA INTERIORS

F

16

3. 4.

FLASH-PATCH / FLOOR STONE ALL AREAS WHERE FLOOR IS NOT LEVEL OR TRUE PRIOR TO FLOORING INSTALLATION GENERAL CONTRACTOR TO SCRAPE EXISTING SLAB FREE OF SCREWS, ADHESIVE AND OTHER MISCELLANEOUS MATERIALS FOR A SMOOTH EVEN FINISH

5. 6.

ALL CARPET TO CARPET AND CARPET TO TILE TRANSITIONS ARE TO BE LEVEL W/SEAMS TIGHTLY BUTTED. FLOAT FLOOR OR PROVIDE UNDERLAYMENT AS NECESSARY ; RE: ARCHITECTURAL FINISH SPECS CENTER FLOORING TRANSITIONS UNDER DOOR UNLESS OTHERWISE POSTED

7.

ALL ROOMS TO BE PAINTED P1 UNLESS NOTED OTHERWISE

8.

ALL WALL OR CEILING GRILLS, GRATES, ACCESS PANELS TO RECEIVE THE WALL FINISH DIRECLTY ADJACENT

NEW LARAMIE HIGH SCHOOL

9.

ALL ELECTRICAL SWITCH AND PLUG PLATES FINISHES TO BE DETERMINED; G.C. TO PROVIDE ALL COLOR OPTIONS TO LBA INTERIORS FOR FINAL COLOR SELECTION

Laramie | Wyoming

10.

CORNER GUARDS ON OUTSIDE CORNERS IN PUBLIC AREAS, UNLESS OTHERWISE NOTED. RE: INTERIOR FINISH SCHEDULE FOR CORNER GUARD TO MATCH PAINT SELECTION

CORRIDOR

11.

ALL ROOMS W/FRP TO BE FULL HEIGHT UNLESS OTHERWISE NOTED

1139

12.

ALL GYP. CEILINGS TO BE P2, UNLESS OTHERWISE NOTED

13.

ALL RUBBER BASE TO BE RB1 UNLESS OTHERWISE NOTED

13.1 12.9

VCT1

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

P6

FLOOR FINISH LEGEND: CORRIDOR VCT1

1174

X

FLOOR FINISH DESIGNATION

FINISH GROUP LEGEND: F1

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

P6

JJ.7 VCT1

VCT7

1172

SC

1170

ST-09.1 SC

E SC

VCT6

WOM

WALK-OFF MAT

RB

RUBBER BASE

SC

STAIR

MECH

CPT

VCT

1168

MAIN ELEC

CPT

T

MAINTENANCE SHOP

JJ

SC

SC

VCT1

1166

GG.3 GG

SC

1164

OFFICE 1162A

1164A

CPT 2 P1, RB1 - SIDE WALLS P3, RB3 - BACK WALL P9, RB9 - TEACHING WALL F9

VINYL COMPOSITION TILE SEALED CONCRETE

INTEGRAL COLOR SEALED CONCRETE

SSC

SLIP RESISTANT, TINTED SEALED CONCRETE

RBT

RUBBER TREAD

LT

LANDING TREAD

E

EPOXY

F3

F4

F5

SHEET VINYL ANTI STATIC VCT

WD

WOOD

RT

RUBBER TILE

F6

RECLAIMED WOOD PLANKS

WALL FINISH LEGEND: JAN

EXTEND EPOXY FLOORING INTO WALK-IN COOLER AND FREEZER

TILE

ISC

RWD

DATA

F2

HARDENED SEALED CONCRETE

AS VCT

CPT 2 F7 P1, RB1 - SIDE WALLS P3, RB3 - TEACHING WALL P9, RB9 - BACK WALL F8

HSC

SV

SUPPLY STORAGE

X X

FINISH MATERIAL ABOVE FINISH MATERIAL BELOW

X

SINGLE FULL HEIGHT WALL FINISH MATERIAL

T7 (FLOOR & WALL) T7.1 T7.2 P1 T2 (FLOOR) T1 (WALL) TR1 T1.1

CPT 4 P1, RB1 - SIDE WALLS P5, RB5 - TEACHING WALL F10 T3 (WALL & FLOOR) T3.1 P9, RB9 - BACK WALL TR1 P1 CPT 4 P1 - SIDE WALLS F11 T3 (WALL & FLOOR) P9 - BACK WALL T3.1 P7 - TEACHING WALL TR1 RB1 T5 T9 T1 (WALL) P1 T1.1 TR1 F12 T3 (WALL & FLOOR) SSC (FLOOR) T3.1 TR1 WOM T4 T1 T9 TR1 P1 T6 T6.1 P1

T1 F13 T3 (WALL & FLOOR) F19 TR1 TR1 T4 T3.1 T4.1 T6 T9 P1

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

F14 T3 (WALL & FLOOR) F20 T1 TR1 TR1 T3.1 T10 T7 T10.1 T9 P1 F15 T3 (WALL & FLOOR) T3.1 TR1 T8 T9 P1

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

F21 T1 TR1 T6 T6.1

E

F22 T1 TR1 T8 T 8.1

F16 SC RB1 P1 FRP FROM FINISHED FLOOR 48" ON (2) WET WALLS F17 EPOXY INTEGRAL BASE P1

T1 F18 TR1 T5 T5.1

TOILET 1162B

F23 T1 TR1 T7 T 7.1 F24 T3 (WALL & FLOOR) T3.1 TR1

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978 Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

ADD ALTERNATE - EPOXY

TRANSITION

COLOR

FLOOR TO FLOOOR MATERIAL

JOHNSONITE SLT-XX-A

TBD

RBT to WOM; CPT to VCT; WOM to VCT; WOM to SV; SV to CPT; RBT to CPT

JOHNSONITE SLT-XX-B

TBD

VCT to RBT

F17

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION:

COMPETITION GYM 1167

EE.2 WD

VCT1

EE DRY STORAGE

D

KITCHEN

1162C

1162

VCT to HSC; VCT to SC; VCT to ISC; SV to SC; SV to WD

JOHNSONITE EG-XX-H

TBD

ALL CONCRETE to CPT

RECLAIMED WOOD PLANKS

SCHLUTER-SCHIENE

TBD

CPT to T; VCT to E; SV to E

P

PAINT

SCHLUTER-RENO U

TBD

VCT to T; SV to T

T

TILE

SCHLUTER-RENO V

TBD

SSC to T

U

UPHOLSTERY, VERTICAL APPLICATION

SCHUTER-HKU

TBD

WT to SV

STONE VENEER

FLOAT FLOOR

N/A

SV to VCT

CORNER GUARD

N/A

N/A

WD to SC (SLAB IS DEPRESSED)

RWD

STV F17

CORRIDOR

JOHNSONITE RRS-XX-C TBD

VCT7

F17

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

ADD ALTERNATE OPTIONS: 1

F16

VCT 1 RB1 P1

FLOOR TRANSITION MATRIX F17

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

D

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

1180

P7 F17 VCT6

P7

CC

CAFETERIA STORAGE 1157

ISSUED FOR CONSTRUCTION

BB.5 P6 P6

SV1

T16 T17

E

T17

T17

SV1

T6 FRONT OF SERVERY

AA

C

F7

UNIFORM STORAGE

1160

EQUIPMENT STORAGE

P6

1165

P6

1161

SV6

1155

SV1

F7

F8

F7

F7

C

FAMILY TOILET

SV7

T16

P6

P6

T16

CONCESSION

1163

A

SERVERY

AA.1

A

SV1

AA.1

SV1

ITEM

#

DATE

DESCRIPTION

SV2

SV1

SV1

x B xCC

SV7 SV2

SV1 SV1

xBB

SV1

SV4

SV1 SV3

SV4 SV1

xAA xA

P6

SV1 SV4

B

COMMONS

B

Seal:

1002 SV3

SV5

P6 F21

SV1 SV1

SV4

SV4

SV1

SV1

SV1

11.6

SV1

SV5 SV4

STAIR SC

D

ST-9.1

Key Plan:

D

SV1

G

E

F

D

C SV1

D.5

B

A

15.9

15

14.2

LBA Project Date

13

A

A

2012.32 15 JANUARY 2014

FIRST LEVEL FINISH PLAN - AREA D

NORTH

1 7

FIRST LEVEL FLOOR FINISH PLAN - AREA D

A13-21D

1/8" = 1'-0"

6

5

4

3

2

1


7

6

5

4

3

2

1

FINISH PLAN GENERAL NOTES:

F

1.

DESIGN DRAWINGS ONLY. CONTRACTOR TO VERIFY ALL APPROPRIATE INSTALLATION AND CONSTRUCTION DETAILS AND ABILITY TO INSTALL PER DESIGN INTENT. PLEASE VERIFY ANY QUESTIONS AND/OR DESCREPANCIES WITH LBA INTERIORS PRIOR TO CONSTRUCTION

2.

CARPET INSTALLATION SHALL COMPLY WITH THE WORKMANSHIP GUIDELINES AS PUBLISHED BY THE AMERICAN CARPET INSTITUTES LATEST EDITION AND SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, PROVIDING AN ATTRACTIVE WRINKLE FREE APPEARANCE. CARPET SEAMS SHALL BE BUTT MATCHED RUNNING IN THE SAME DIRECTION. PROVIDE SEAMING DIAGRAM FOR APPROVAL BY LBA INTERIORS

3. 4.

FLASH-PATCH / FLOOR STONE ALL AREAS WHERE FLOOR IS NOT LEVEL OR TRUE PRIOR TO FLOORING INSTALLATION GENERAL CONTRACTOR TO SCRAPE EXISTING SLAB FREE OF SCREWS, ADHESIVE AND OTHER MISCELLANEOUS MATERIALS FOR A SMOOTH EVEN FINISH

5. 6.

ALL CARPET TO CARPET AND CARPET TO TILE TRANSITIONS ARE TO BE LEVEL W/SEAMS TIGHTLY BUTTED. FLOAT FLOOR OR PROVIDE UNDERLAYMENT AS NECESSARY ; RE: ARCHITECTURAL FINISH SPECS CENTER FLOORING TRANSITIONS UNDER DOOR UNLESS OTHERWISE POSTED

7.

ALL ROOMS TO BE PAINTED P1 UNLESS NOTED OTHERWISE ALL WALL OR CEILING GRILLS, GRATES, ACCESS PANELS TO RECEIVE THE WALL FINISH DIRECLTY ADJACENT

9.

ALL ELECTRICAL SWITCH AND PLUG PLATES FINISHES TO BE DETERMINED; G.C. TO PROVIDE ALL COLOR OPTIONS TO LBA INTERIORS FOR FINAL COLOR SELECTION CORNER GUARDS ON OUTSIDE CORNERS IN PUBLIC AREAS, UNLESS OTHERWISE NOTED. RE: INTERIOR FINISH SCHEDULE FOR CORNER GUARD TO MATCH PAINT SELECTION

11.

ALL ROOMS W/FRP TO BE FULL HEIGHT UNLESS OTHERWISE NOTED

12.

ALL GYP. CEILINGS TO BE P2, UNLESS OTHERWISE NOTED

13.

ALL RUBBER BASE TO BE RB1 UNLESS OTHERWISE NOTED

F1

CPT

WOM

WALK-OFF MAT

RB

RUBBER BASE

T VCT SC

F2

TILE F3

SEALED CONCRETE HARDENED SEALED CONCRETE

ISC

INTEGRAL COLOR SEALED CONCRETE

SSC

SLIP RESISTANT, TINTED SEALED CONCRETE

RBT

RUBBER TREAD

LT

LANDING TREAD

E

EPOXY

AS VCT

F4

F5

SHEET VINYL ANTI STATIC VCT

WD

WOOD

RT

RUBBER TILE

RWD

CPT 2 P1, RB1 - SIDE WALLS P3, RB3 - BACK WALL P9, RB9 - TEACHING WALL F9

VINYL COMPOSITION TILE

HSC

SV

E

F8

F6

RECLAIMED WOOD PLANKS

WALL FINISH LEGEND:

VCT 1 RB1 P1 T7 (FLOOR & WALL) T7.1 T7.2 P1 T2 (FLOOR) T1 (WALL) TR1 T1.1

CPT 4 P1, RB1 - SIDE WALLS P5, RB5 - TEACHING WALL F10 T3 (WALL & FLOOR) T3.1 P9, RB9 - BACK WALL TR1 P1 CPT 4 P1 - SIDE WALLS F11 T3 (WALL & FLOOR) P9 - BACK WALL T3.1 P7 - TEACHING WALL TR1 RB1 T5 T9 T1 (WALL) P1 T1.1 TR1 F12 T3 (WALL & FLOOR) SSC (FLOOR) T3.1 TR1 WOM T4 T1 T9 TR1 P1 T6 T6.1 P1

Laramie | Wyoming T1 F13 T3 (WALL & FLOOR) F19 TR1 TR1 T4 T3.1 T4.1 T6

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

T9 P1 F14 T3 (WALL & FLOOR) F20 T1 TR1 TR1 T3.1 T10 T7 T10.1 T9 P1 F15 T3 (WALL & FLOOR) T3.1 TR1 T8 T9 P1

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

F21 T1 TR1 T6 T6.1 F22 T1 TR1 T8 T 8.1

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

F23 T1 TR1 T7 T 7.1

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022

F16 SC RB1 P1 FRP FROM FINISHED FLOOR 48" ON (2) WET WALLS F17 EPOXY INTEGRAL BASE P1

T1 F18 TR1 T5 T5.1

E

F24 T3 (WALL & FLOOR) T3.1 TR1

Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

ADD ALTERNATE OPTIONS:

X X

FINISH MATERIAL ABOVE FINISH MATERIAL BELOW

X

SINGLE FULL HEIGHT WALL FINISH MATERIAL

ADD ALTERNATE - EPOXY

1

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

FLOOR TRANSITION MATRIX

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION:

15.5

13.6

13.1 12.9

COLOR

FLOOR TO FLOOOR MATERIAL

JOHNSONITE SLT-XX-A

TBD

RBT to WOM; CPT to VCT; WOM to VCT; WOM to SV; SV to CPT; RBT to CPT

JOHNSONITE SLT-XX-B

TBD

VCT to RBT

JOHNSONITE RRS-XX-C TBD

VCT to HSC; VCT to SC; VCT to ISC; SV to SC; SV to WD

JOHNSONITE EG-XX-H

TBD

ALL CONCRETE to CPT

RECLAIMED WOOD PLANKS

SCHLUTER-SCHIENE

TBD

CPT to T; VCT to E; SV to E

P

PAINT

SCHLUTER-RENO U

TBD

VCT to T; SV to T

T

TILE

SCHLUTER-RENO V

TBD

SSC to T

U

UPHOLSTERY, VERTICAL APPLICATION

SCHUTER-HKU

TBD

WT to SV

STONE VENEER

FLOAT FLOOR

N/A

SV to VCT

CORNER GUARD

N/A

N/A

WD to SC (SLAB IS DEPRESSED)

RWD

16

TRANSITION

STV

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187 Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

D

D

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

WW

STORAGE 1169A

SS SC

ISSUED FOR CONSTRUCTION

TT

P6 F6

VESTIBULE 1208 P6

C

C

P6

CORRIDOR 1206

VCT6

ITEM

#

DATE

DESCRIPTION

PP CORRIDOR 1180

AUXILIARY GYM

VCT1

B

B

Seal:

1169

WD

P6 VCT6

MM.9

1"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

CPT 2 F7 P1, RB1 - SIDE WALLS P3, RB3 - TEACHING WALL P9, RB9 - BACK WALL

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

NEW LARAMIE HIGH SCHOOL

FINISH GROUP LEGEND:

FLOOR FINISH DESIGNATION

CPT

Ph: 303.773.0436 | Fax: 303.773.8709 IN ASSOCIATION WITH:

10.

X

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

F

8.

FLOOR FINISH LEGEND:

Lantz-Boggio Architects, P.C.

MM.6 RECEIVING 1176

MECH

SC

1178

SC

Key Plan:

MM P7

VCT1

A

1139

LBA Project Date

P6

CORRIDOR 1174

D

LL CORRIDOR

A

F

B

SC VCT1

E C

P7

OFFICE 1176A

G

A

VCT1

P6

2012.32 15 JANUARY 2014

FIRST LEVEL FINISH PLAN - AREA E

NORTH

1 7

6

5

A13-21E

FIRST LEVEL FLOOR FINISH PLAN- AREA E 1/8" = 1'-0" 4

3

2

1


7

6

5

4

3

2

1

Lantz-Boggio Architects, P.C.

FINISH PLAN GENERAL NOTES: DESIGN DRAWINGS ONLY. CONTRACTOR TO VERIFY ALL APPROPRIATE INSTALLATION AND CONSTRUCTION DETAILS AND ABILITY TO INSTALL PER DESIGN INTENT. PLEASE VERIFY ANY QUESTIONS AND/OR DESCREPANCIES WITH LBA INTERIORS PRIOR TO CONSTRUCTION

2.

CARPET INSTALLATION SHALL COMPLY WITH THE WORKMANSHIP GUIDELINES AS PUBLISHED BY THE AMERICAN CARPET INSTITUTES LATEST EDITION AND SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, PROVIDING AN ATTRACTIVE WRINKLE FREE APPEARANCE. CARPET SEAMS SHALL BE BUTT MATCHED RUNNING IN THE SAME DIRECTION. PROVIDE SEAMING DIAGRAM FOR APPROVAL BY LBA INTERIORS

3. 4.

FLASH-PATCH / FLOOR STONE ALL AREAS WHERE FLOOR IS NOT LEVEL OR TRUE PRIOR TO FLOORING INSTALLATION GENERAL CONTRACTOR TO SCRAPE EXISTING SLAB FREE OF SCREWS, ADHESIVE AND OTHER MISCELLANEOUS MATERIALS FOR A SMOOTH EVEN FINISH

5. 6.

ALL CARPET TO CARPET AND CARPET TO TILE TRANSITIONS ARE TO BE LEVEL W/SEAMS TIGHTLY BUTTED. FLOAT FLOOR OR PROVIDE UNDERLAYMENT AS NECESSARY ; RE: ARCHITECTURAL FINISH SPECS CENTER FLOORING TRANSITIONS UNDER DOOR UNLESS OTHERWISE POSTED

VEST

7.

ALL ROOMS TO BE PAINTED P1 UNLESS NOTED OTHERWISE

1189B

8.

ALL WALL OR CEILING GRILLS, GRATES, ACCESS PANELS TO RECEIVE THE WALL FINISH DIRECLTY ADJACENT

9.

ALL ELECTRICAL SWITCH AND PLUG PLATES FINISHES TO BE DETERMINED; G.C. TO PROVIDE ALL COLOR OPTIONS TO LBA INTERIORS FOR FINAL COLOR SELECTION

10.

CORNER GUARDS ON OUTSIDE CORNERS IN PUBLIC AREAS, UNLESS OTHERWISE NOTED. RE: INTERIOR FINISH SCHEDULE FOR CORNER GUARD TO MATCH PAINT SELECTION

11.

ALL ROOMS W/FRP TO BE FULL HEIGHT UNLESS OTHERWISE NOTED

NEW LARAMIE HIGH SCHOOL

12.

ALL GYP. CEILINGS TO BE P2, UNLESS OTHERWISE NOTED

Laramie | Wyoming

13.

ALL RUBBER BASE TO BE RB1 UNLESS OTHERWISE NOTED

17.2

16.4

16

F

OFFICIALS

STAFF

1194

1196

SC

MEN'S SHOWERS

TOILET F8

1187A

1187B F7

ENTRY VEST

1

1187

SC

F7

P6 VCT6

1"

F9

NN

VEST 1185A

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

PE OFFICE

MEN'S PE LOCKERS

SC

SSC

MM.6

FLOOR FINISH LEGEND: X

1193

1

CPT F7

LL.5

WALK-OFF MAT

RB

RUBBER BASE

VCT

LL

TOILET F8

1193A

VCT1

WOMEN'S PE LOCKERS

DATA

P6

1183 SSC

1177

VEST

1 SC

SC 18

1175A

F9

F8

VEST

A08-21

30

SC

ENTRY VEST

1

1175

TILE

SEALED CONCRETE

INTEGRAL COLOR SEALED CONCRETE

SSC

SLIP RESISTANT, TINTED SEALED CONCRETE

RBT

RUBBER TREAD

LT

LANDING TREAD

E

EPOXY

RWD

SC

ANTI STATIC VCT WOOD F6

RUBBER TILE RECLAIMED WOOD PLANKS

WALL FINISH LEGEND: X X

FINISH MATERIAL ABOVE FINISH MATERIAL BELOW

X

SINGLE FULL HEIGHT WALL FINISH MATERIAL

IN ASSOCIATION WITH:

T7 (FLOOR & WALL) T7.1 T7.2 P1 T2 (FLOOR) T1 (WALL) TR1 T1.1

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

T1 F13 T3 (WALL & FLOOR) F19 TR1 TR1 T4 T3.1 T4.1 T6 T9 P1

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

F14 T3 (WALL & FLOOR) F20 T1 TR1 TR1 T3.1 T10 T7 T10.1 T9 P1 F15 T3 (WALL & FLOOR) T3.1 TR1 T8 T9 P1

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

F21 T1 TR1 T6 T6.1 F22 T1 TR1 T8 T 8.1

F16 SC RB1 P1 FRP FROM FINISHED FLOOR 48" ON (2) WET WALLS F17 EPOXY INTEGRAL BASE P1

T1 F18 TR1 T5 T5.1

PE OFFICE

SSC

1171

E

F23 T1 TR1 T7 T 7.1

1

TOILET

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION:

F8

F24 T3 (WALL & FLOOR) T3.1 TR1

ADD ALTERNATE OPTIONS:

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

ADD ALTERNATE - EPOXY

TRANSITION

COLOR

FLOOR TO FLOOOR MATERIAL

JOHNSONITE SLT-XX-A

TBD

RBT to WOM; CPT to VCT; WOM to VCT; WOM to SV; SV to CPT; RBT to CPT

JOHNSONITE SLT-XX-B

TBD

VCT to RBT

JOHNSONITE RRS-XX-C TBD

VCT to HSC; VCT to SC; VCT to ISC; SV to SC; SV to WD

JOHNSONITE EG-XX-H

TBD

ALL CONCRETE to CPT

RECLAIMED WOOD PLANKS

SCHLUTER-SCHIENE

TBD

CPT to T; VCT to E; SV to E

P

PAINT

SCHLUTER-RENO U

TBD

VCT to T; SV to T

T

TILE

SCHLUTER-RENO V

TBD

SSC to T

U

UPHOLSTERY, VERTICAL APPLICATION

SCHUTER-HKU

TBD

WT to SV

STONE VENEER

FLOAT FLOOR

N/A

SV to VCT

CORNER GUARD

N/A

N/A

WD to SC (SLAB IS DEPRESSED)

1171A RWD

GG SPORTS MEDICINE

STV

1195B

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

VCT6

F7

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

FLOOR TRANSITION MATRIX

1173

SC

VCT 1 RB1 P1

CPT 4 P1, RB1 - SIDE WALLS P5, RB5 - TEACHING WALL F10 T3 (WALL & FLOOR) T3.1 P9, RB9 - BACK WALL TR1 P1 CPT 4 P1 - SIDE WALLS F11 T3 (WALL & FLOOR) P9 - BACK WALL T3.1 P7 - TEACHING WALL TR1 RB1 T5 T9 T1 (WALL) P1 T1.1 TR1 F12 T3 (WALL & FLOOR) SSC (FLOOR) T3.1 TR1 WOM T4 T1 T9 TR1 P1 T6 T6.1 P1

1

WOMEN'S ATHLETIC LOCKERS

D

F4

F5

SHEET VINYL

1173A

JJ

F3

VCT1

24

CPT 2 P1, RB1 - SIDE WALLS P3, RB3 - BACK WALL P9, RB9 - TEACHING WALL F9

VINYL COMPOSITION TILE

ISC

RT

WOMEN'S TOILET

F2

HARDENED SEALED CONCRETE

WD

CPT 2 F7 P1, RB1 - SIDE WALLS P3, RB3 - TEACHING WALL P9, RB9 - BACK WALL F8

HSC

AS VCT P6

1175B

SC

SV

1177B

SHOWERS

F1

CPT

WOM

T

E

FLOOR FINISH DESIGNATION

Ph: 303.773.0436 | Fax: 303.773.8709

FINISH GROUP LEGEND:

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

1185

POOL

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

1.

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

D

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

RAF

1188

OFFICE 1195A

EE.2

CPT1 VCT1

OFFICE

STOR

1197B

1197A

ISSUED FOR CONSTRUCTION

CPT1

CPT1

CORRIDOR 1180

FITNESS/ WEIGHT 1197

RAF

VCT6

CC 18 C

C

P6 P6

ITEM

#

DATE

DESCRIPTION

SV1

AA

SV6

A

A SV1

SV1

B

SV1

B

B SV1

SV6

Seal:

T11 SV6

T11.1

SV2

SV3

SV1

SV1

C Key Plan: SV1

G

E

F

D

C

SV4

C.5

SV3

B SV4

SV1

A

LBA Project Date

C.8 A

A

21

22

20

19

17.9

17

2012.32 15 JANUARY 2014

FIRST LEVEL FINISH PLAN - AREA F

15.9

NORTH

1 7

A13-21F

LEVEL ONE FLOOR FINISH PLAN - AREA F 1/8" = 1'-0" 6

5

4

3

2

1


7

6

5

4

3

2

1

Lantz-Boggio Architects, P.C.

FINISH PLAN GENERAL NOTES:

F

1.

DESIGN DRAWINGS ONLY. CONTRACTOR TO VERIFY ALL APPROPRIATE INSTALLATION AND CONSTRUCTION DETAILS AND ABILITY TO INSTALL PER DESIGN INTENT. PLEASE VERIFY ANY QUESTIONS AND/OR DESCREPANCIES WITH LBA INTERIORS PRIOR TO CONSTRUCTION

2.

CARPET INSTALLATION SHALL COMPLY WITH THE WORKMANSHIP GUIDELINES AS PUBLISHED BY THE AMERICAN CARPET INSTITUTES LATEST EDITION AND SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, PROVIDING AN ATTRACTIVE WRINKLE FREE APPEARANCE. CARPET SEAMS SHALL BE BUTT MATCHED RUNNING IN THE SAME DIRECTION. PROVIDE SEAMING DIAGRAM FOR APPROVAL BY LBA INTERIORS

IN ASSOCIATION WITH:

FLASH-PATCH / FLOOR STONE ALL AREAS WHERE FLOOR IS NOT LEVEL OR TRUE PRIOR TO FLOORING INSTALLATION GENERAL CONTRACTOR TO SCRAPE EXISTING SLAB FREE OF SCREWS, ADHESIVE AND OTHER MISCELLANEOUS MATERIALS FOR A SMOOTH EVEN FINISH

5. 6.

ALL CARPET TO CARPET AND CARPET TO TILE TRANSITIONS ARE TO BE LEVEL W/SEAMS TIGHTLY BUTTED. FLOAT FLOOR OR PROVIDE UNDERLAYMENT AS NECESSARY ; RE: ARCHITECTURAL FINISH SPECS CENTER FLOORING TRANSITIONS UNDER DOOR UNLESS OTHERWISE POSTED

7.

ALL ROOMS TO BE PAINTED P1 UNLESS NOTED OTHERWISE

8.

ALL WALL OR CEILING GRILLS, GRATES, ACCESS PANELS TO RECEIVE THE WALL FINISH DIRECLTY ADJACENT

9.

ALL ELECTRICAL SWITCH AND PLUG PLATES FINISHES TO BE DETERMINED; G.C. TO PROVIDE ALL COLOR OPTIONS TO LBA INTERIORS FOR FINAL COLOR SELECTION

10.

CORNER GUARDS ON OUTSIDE CORNERS IN PUBLIC AREAS, UNLESS OTHERWISE NOTED. RE: INTERIOR FINISH SCHEDULE FOR CORNER GUARD TO MATCH PAINT SELECTION

11.

ALL ROOMS W/FRP TO BE FULL HEIGHT UNLESS OTHERWISE NOTED

12.

ALL GYP. CEILINGS TO BE P2, UNLESS OTHERWISE NOTED

NEW LARAMIE HIGH SCHOOL

13.

ALL RUBBER BASE TO BE RB1 UNLESS OTHERWISE NOTED

Laramie | Wyoming

F1

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

F8

CPT

CPT

WOM

WALK-OFF MAT

RB

RUBBER BASE

F2

TILE

T VCT

VINYL COMPOSITION TILE

SC

SEALED CONCRETE

F3

HSC

HARDENED SEALED CONCRETE

ISC

INTEGRAL COLOR SEALED CONCRETE

SSC

SLIP RESISTANT, TINTED SEALED CONCRETE

RBT

RUBBER TREAD

LT

LANDING TREAD

E

EPOXY

F4

F5

SHEET VINYL

SV

ANTI STATIC VCT

AS VCT WD

WOOD

RT

RUBBER TILE

F6

RECLAIMED WOOD PLANKS

RWD

CPT 2 F7 P1, RB1 - SIDE WALLS P3, RB3 - TEACHING WALL P9, RB9 - BACK WALL

WALL FINISH LEGEND:

CPT 2 P1, RB1 - SIDE WALLS P3, RB3 - BACK WALL P9, RB9 - TEACHING WALL F9

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

T1 F13 T3 (WALL & FLOOR) F19 TR1 TR1 T4 T3.1 T4.1 T6

VCT 1 RB1 P1 T7 (FLOOR & WALL) T7.1 T7.2 P1 T2 (FLOOR) T1 (WALL) TR1 T1.1

CPT 4 P1, RB1 - SIDE WALLS P5, RB5 - TEACHING WALL F10 T3 (WALL & FLOOR) T3.1 P9, RB9 - BACK WALL TR1 P1 CPT 4 P1 - SIDE WALLS F11 T3 (WALL & FLOOR) P9 - BACK WALL T3.1 P7 - TEACHING WALL TR1 RB1 T5 T9 T1 (WALL) P1 T1.1 TR1 F12 T3 (WALL & FLOOR) SSC (FLOOR) T3.1 TR1 WOM T4 T1 T9 TR1 P1 T6 T6.1 P1

T9 P1

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

F14 T3 (WALL & FLOOR) F20 T1 TR1 TR1 T3.1 T10 T7 T10.1 T9 P1 F15 T3 (WALL & FLOOR) T3.1 TR1 T8 T9 P1

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

F21 T1 TR1 T6 T6.1 F22 T1 TR1 T8 T 8.1

F16 SC RB1 P1 FRP FROM FINISHED FLOOR 48" ON (2) WET WALLS F17 EPOXY INTEGRAL BASE P1

T1 F18 TR1 T5 T5.1

E

F23 T1 TR1 T7 T 7.1

FINISH MATERIAL ABOVE FINISH MATERIAL BELOW

X

SINGLE FULL HEIGHT WALL FINISH MATERIAL

F24 T3 (WALL & FLOOR) T3.1 TR1

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

ADD ALTERNATE - EPOXY

1

FLOOR TRANSITION MATRIX TRANSITION

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION:

COLOR

FLOOR TO FLOOOR MATERIAL

JOHNSONITE SLT-XX-A

TBD

RBT to WOM; CPT to VCT; WOM to VCT; WOM to SV; SV to CPT; RBT to CPT

JOHNSONITE SLT-XX-B

TBD

VCT to RBT

JOHNSONITE RRS-XX-C TBD

VCT to HSC; VCT to SC; VCT to ISC; SV to SC; SV to WD

JOHNSONITE EG-XX-H

TBD

ALL CONCRETE to CPT

RECLAIMED WOOD PLANKS

SCHLUTER-SCHIENE

TBD

CPT to T; VCT to E; SV to E

P

PAINT

SCHLUTER-RENO U

TBD

VCT to T; SV to T

T

TILE

SCHLUTER-RENO V

TBD

SSC to T

U

UPHOLSTERY, VERTICAL APPLICATION

SCHUTER-HKU

TBD

WT to SV

STONE VENEER

FLOAT FLOOR

N/A

SV to VCT

CORNER GUARD

N/A

N/A

WD to SC (SLAB IS DEPRESSED)

RWD

STV

D

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

ADD ALTERNATE OPTIONS:

X X

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

FINISH GROUP LEGEND:

FLOOR FINISH DESIGNATION

X

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187 Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

D

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

16

ISSUED FOR CONSTRUCTION

UU FAMILY TOILET

CONCESSIONS 1212

C

VEST

VEST

1209B

1207B

SC

SC

SC

VEST SC

1201D

SC

STORAGE

VESTIBULE

1202

1199D

SC

C

1211

SC 21

21

A12-16

A12-16

TT

TT 18 SIM

A08-21

A08-21 24 24 SIM SIM

18 SIM

VISITOR LOCKER ROOM

A08-21 24 24 SIM SIM

F5

F5

F5

TOILETS

TOILETS

1199A

1201A

1201

SIM A08-21 18

EXTERIOR STORAGE

CUSTODIAL STORAGE

1214

1213

MENS TOILET

WOMENS TOILET

1209

1207

18 SIM

1

18

A08-21

SSC

1

#

DATE

DESCRIPTION

P6

18

24

SSC

F8

1

F6

VESTIBULE 1208

F8 P6

25 SSC

SC

SSC

ITEM

1199 A08-21

24 F5

HOME LOCKER ROOM

A08-21 25

A08-21

1

P6

SHOWERS

SC

SHOWERS

1201B

1199B F9

FAMILY TOILET 1210

F9

CORRIDOR 1206

SC

VESTIBULE SC

1209A

VESTIBULE

DATA

1207A

1201E

SC

SC

VESTIBULE

JAN

1201C

1203

SC

VESTIBULE VCT6

1199C

SC

F16

RR B

CORRIDOR

CORRIDOR

B

1204

Seal:

1202 VCT1 VCT1

QQ SC

STAIR

ELEVATOR CONTROL ROOM

ST-12.1

1200 VCT1

POOL EQUIPMENT 1190

VCT1

F16

JAN ELEVATOR

1192

EL-03

SC

1191

SC

POOL STORAGE

SC

ELEC

1179

TOILET

TOILET

F8

1194A

1196A

F16

MEN'S ATHLETIC LOCKERS

CPT1

LAUNDRY

1194

1196

SC

MEN'S SHOWERS

TOILET 1187A

F8

F7 F9

NN

VCT1

F16

1187B F7

E

F

D

1182

1189B

STAFF

G

C

1

VEST OFFICIALS

Key Plan:

1180 SSC

1189

F8

CORRIDOR

ENTRY VEST

1

1187

SC

B

P6

A VCT6

1"

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

Ph: 303.773.0436 | Fax: 303.773.8709

3. 4.

FLOOR FINISH LEGEND:

E

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

VEST 1185A

MEN'S PE LOCKERS

SC

A

LBA Project Date

PE OFFICE SSC

1

1193 A

1185

2012.32 15 JANUARY 2014

FIRST LEVEL FINISH PLAN - AREA G

NORTH

1 7

6

5

A13-21G

FIRST LEVEL FLOOR FINISH PLAN - AREA G 1/8" = 1'-0" 4

3

2

1


NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

F

E

D

C

B

A

7

6.

5.

3. 4.

2.

1.

ALL ROOMS TO BE PAINTED P1 UNLESS NOTED OTHERWISE

ALL CARPET TO CARPET AND CARPET TO TILE TRANSITIONS ARE TO BE LEVEL W/SEAMS TIGHTLY BUTTED. FLOAT FLOOR OR PROVIDE UNDERLAYMENT AS NECESSARY ; RE: INTERIOR FINISH SPECS. CENTER FLOORING TRANSITIONS UNDER DOOR UNLESS OTHERWISE POSTED.

FLASH-PATCH / FLOOR STONE ALL AREAS WHERE FLOOR IS NOT LEVEL OR TRUE PRIOR TO FLOORING INSTALLATION. GENERAL CONTRACTOR TO SCRAPE EXISTING SLAB FREE OF SCREWS, ADHESIVE AND OTHER MISCELLANEOUS MATERIALS FOR A SMOOTH EVEN FINISH.

CARPET INSTALLATION SHALL COMPLY WITH THE WORKMANSHIP GUIDELINES AS PUBLISHED BY THE AMERICAN CARPET INSTITUTES LATEST EDITION AND SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, PROVIDING AN ATTRACTIVE WRINKLE FREE APPEARANCE. CARPET SEAMS SHALL BE BUTT MATCHED RUNNING IN THE SAME DIRECTION. PROVIDE SEAMING DIAGRAM FOR APPROVAL BY LBA INTERIORS.

DESIGN DRAWINGS ONLY. CONTRACTOR TO VERIFY ALL APPROPRIATE INSTALLATION AND CONSTRUCTINO DETAILS AND ABILITY TO INSTALL PER DESIGN INTENT. PLEASE VERIFY ANY QUESTIONS AND/OR DESCREPANCIES WITH LBA INTERIORS PRIOR TO CONSTRUCTION.

SSC

ISC

HSC

SC

VCT

RUBBER TREAD

SLIP RESISTANT, TINTED SEALED CONCRETE

INTEGRAL COLOR SEALED CONCRETE

HARDENED SEALED CONCRETE

SEALED CONCRETE

VINYL COMPOSITION TILE

6

7.

RBT

FLOOR FINISH LEGEND:

8.

ALL WALL OR CEILING GRILLS, GRATES, ACCESS PANELS TO RECIEVE THE WALL FINISH DIRECLTY ADJACENT. FOR WALLS, IF THE FINISH IS WALL VINYL, PLEASE PAINT TO MATCH WALL VINYL: INTERIOR DESIGNER TO SELECT COLOR. ALL ELECTRICAL SWITCH AND PLUG PLATES FINISHES TO BE DETERMINED; G.C. TO PROVIDE ALL COLOR OPTIONS TO LBA INTERIORS FOR FINAL COLOR SELECTION CORNER GUARDS ON OUTSIDE CORNERS IN PUBLIC AREAS, UNLESS OTHERWISE NOTED. RE: INTERIOR FINISH SCHEDULE FOR CORNER GUARD TO MATCH PAINT SELECTION. ALL ROOMS W/FRP TO BE FULL HEIGHT UNLESS OTHERWISE NOTED

RB

WOM

CPT

RUBBER BASE

WALK-OFF MAT

CPT

EPOXY

TILE

E

SHEET VINYL

WD

RUBBER TILE

WOOD

ANTI STATIC VCT

RT

RECLAIMED WOOD PLANKS

X X SINGLE FULL HEIGHT WALL FINISH MATERIAL

FINISH MATERIAL ABOVE FINISH MATERIAL BELOW

PAINT

RECLAIMED WOOD PLANKS

P TILE

RWD

T

12

UPHOLSTERY, VERTICAL APPLICATION STONE VENEER

P9

U STV CORNER GUARD

P1

CLASSROOM 2081

F2 TYP.

P1

5

2083

2071

F1

F2

F3

F4

F5

F6

CORRIDOR CPT3

STADIUM SEATING

x12

5

2075

CORRIDOR

DISTRIBUTED MEDIA / LEARNING STREET

P3

2076

CPT3

x13

2086

2074

CLASSROOM

CLASSROOM

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

X

WALL FINISH LEGEND:

RWD

AS VCT

SV

T

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

FLOOR FINISH DESIGNATION

9. 10. 11. ALL GYP. CEILINGS TO BE P2, UNLESS OTHERWISE NOTED

X

12. LANDING TREAD

12.8

P3

2084

CLASSROOM

P3

LT

FLOOR TRANSITION MATRIX FLOOR TO FLOOOR MATERIAL

WT to SV

P3

ALL RUBBER BASE TO BE RB1, UNLESS OTHERWISE NOTED

COLOR RBT to WOM; CPT to VCT; WOM to VCT; WOM to SV; SV to CPT; RBT to CPT

TRANSITION TBD

ALL CONCRETE to CPT

JOHNSONITE SLT-XX-A

TBD CPT to T; VCT to E; SV to E

VCT to RBT

JOHNSONITE EG-XX-H TBD VCT to T; SV to T

TBD

SCHLUTER-SCHIENE TBD SSC to T

JOHNSONITE SLT-XX-B

SCHLUTER-RENO U TBD TBD

14x15.3

2077

2073

CORRIDOR

P3

F7

2082

SPECIAL ED CLASSROOM

CPT2

CLASSROOM

2079

CLASSROOM

VCT to HSC; VCT to SC; VCT to ISC; SV to SC; SV to WD

SCHLUTER-RENO V SCHUTER-HKU

WD to SC (SLAB IS DEPRESSED)

SV to VCT

N/A

N/A

N/A

T

STV

CPT1

ST-06.2

STAIR

STV

x15

P3

P3

JOHNSONITE RRS-XX-C TBD

xH

FLOAT FLOOR

xJ

xJ.5

xK

xL

STAIRS TO BE RUBBER TREAD LANDING TO BE LANDING TREAD WALK-OFF MAT BELOW

LT STV

RBT

x15.3

1/8" = 1'-0" 6

SECOND LEVEL FLOOR FINISH PLAN - AREA A

x14.1

P3

13.

FINISH PLAN GENERAL NOTES:

xM

1 7

FINISH GROUP LEGEND:

P

SMALL GROUP 2091 CPT2

CLASSROOM 2090

4

MEN'S TOILET 2055

2061

WOMEN'S TOILET

2085

ISC

2053

SCIENCE

F15

F24

2057

JAN

2059

2055A

F16

SC

F24

P3

VESTIBULE

DATA

VESTIBULE 2061A

2087

SP ED OFFICE

2065

CPT2

P3

x7.3

P3

CONFERENCE

CPT2

CPT2

2085A

2092

CLASSROOM

CPT2

2093

WORKROOM/ PLANNING/ STORAGE

2067

CORRIDOR

CPT2

WAITING

F15

SC

TLT 2093A A08-22 F8

GUIDANCE

CPT2

ELEC 2063 SC

2093B 24

CLOSET

9.3

STORAGE 2089 F7

x9.1

9.3

CPT2

F24 T3 (WALL & FLOOR) T3.1 TR1

F23 T1 TR1 T7 T 7.1

T1 CPT 2 F7 VCT 1 F13 T3 (WALL & FLOOR) F19 TR1 P1, RB1 - SIDE WALLS RB1 TR1 T4 P3, RB3 - TEACHING WALL P1 T3.1 T4.1 P9, RB9 - BACK WALL T6 F8 T7 (FLOOR & WALL) T9 T7.1 P1 CPT 2 T7.2 P1, RB1 - SIDE WALLS P1 F14 T3 (WALL & FLOOR) F20 T1 TR1 TR1 P3, RB3 - BACK WALL T3.1 T10 P9, RB9 - TEACHING WALL F9 T2 (FLOOR) T7 T10.1 T1 (WALL) T9 TR1 P1 T1.1 CPT 4 P1, RB1 - SIDE WALLS P5, RB5 - TEACHING WALL F10 T3 (WALL & FLOOR) F15 T3 (WALL & FLOOR) F21 T1 T3.1 T3.1 P9, RB9 - BACK WALL TR1 TR1 TR1 T6 P1 T8 T6.1 CPT 4 T9 P1 - SIDE WALLS P1 F11 T3 (WALL & FLOOR) F22 T1 P9 - BACK WALL T3.1 TR1 P7 - TEACHING WALL F16 SC TR1 T8 RB1 RB1 T5 T 8.1 P1 T9 FRP FROM FINISHED FLOOR P1 48" ON (2) WET WALLS

T1 F18 TR1 T5 T5.1

F12 T3 (WALL & FLOOR) F17 EPOXY T3.1 INTEGRAL BASE TR1 P1 T4 T9 P1

10.8

ADD ALTERNATE - EPOXY

P3

2078

CPT3

P3

DISTRIBUTED MEDIA / LEARNING STREET

ADD ALTERNATE OPTIONS:

T1 (WALL) T1.1 TR1 SSC (FLOOR) WOM T1 TR1 T6 T6.1 P1

1

P3

CLASSROOM 2088

x11

4

8

P3

P3

P3

VCT1

P1 F22

A12-16

P1 F22

VCT1

2037

P1 F22

VCT3

P1 F22

3

7

P3

P3

P3

17 RWD P3

P1 F22

A12-16

2070

2068

7

P3

P1 F22

VCT1

RBT

RBT

P1 F22

ELEVATOR EL-01

CPT1

SC

VCT3

P3

VCT3

CORRIDOR

CORRIDOR

P1 F22

VCT1

VCT1

P1 F22

2070

CORRIDOR

9

VCT3

CORRIDOR

T14 A12-16 21

P3

8

3

P3

P3

ISC

SCIENCE 2052 ISC

ISC

R&D 2054

6.2

R&D PREP 2054A

ISC

R&D 2058

2064

R&D

ISC

5.2

5.2

5

5

2

Q

R

2

OPEN TO BELOW

x4.1

x4.1

1

1

U

V

W

X

Y

NORTH

F

E

D

C

B

A

Lantz-Boggio Architects, P.C.

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

Ph: 303.773.0436 | Fax: 303.773.8709

IN ASSOCIATION WITH:

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

NEW LARAMIE HIGH SCHOOL

Laramie | Wyoming

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022

Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

#

F

G

D

E

DATE

2012.32 15 JANUARY 2014

A

B

C

DESCRIPTION

ISSUED FOR CONSTRUCTION

ITEM

Seal:

Key Plan:

LBA Project Date

SECOND LEVEL FINISH PLAN - AREA A

A13-22A


7

6

5

F21

11.6

4

x9.2 x9

F21

3

2

1

HH.4

Lantz-Boggio Architects, P.C.

CONFERENCE 2104

AA.1

A

P1 F21

P1 F21

P1 F21

P6

RBT

CORRIDOR

CPT6

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111 Ph: 303.773.0436 | Fax: 303.773.8709

AA.1 A

IN ASSOCIATION WITH:

RBT

2002 CPT1

F

CORRIDOR 2001

8

B

7

CPT1

x x14

6

NEW LARAMIE HIGH SCHOOL

ROOF BELOW

Laramie | Wyoming

34

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

9.5

A12-16 VCT1 NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

35

8.5

P6

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

CORRIDOR 2001

x10

P1 F21

xCC x8

CORRIDOR

xBB

2002 P1 F21

OPEN TO BELOW

SOUND 2106 CPT1

MEDIA LAB

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

P6

x7

xAA

P1 F21

x6 P7

2108 E CPT1

x5

VCT3

SC

D

E

CONTROL 2105

CORRIDOR

P1 F23

P1 F23

CPT1

P1

2011

x3

x2

CLASSROOM CLASSROOM

2013

EDITING

F4

P7

VCT3

CPT1

P9

CLASSROOM 2017

CLASSROOM P7

HEAD END

2111

STAIR

2019

P7

ST-01.2

P7

VCT7 CPT3

2109

CORRIDOR

ASVCT ASVCT

2003

STV

P7

SPECIAL ED CLASSROOM

P1

VCT7

Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

xA

CPT1

LT

2021

F

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187

bb

STV

P7

VCT1

IT TECH

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

TYP.

VCT1

2102

x1

2015

VCT1

E

Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

x4

CLASSROOM

2003

RBT

P7 F7

P7 VCT1

P7

CORRIDOR

VCT1

D

2028

WORKROOM/ PLANNING/ STORAGE

ROOF BELOW

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022

D CPT5

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

P7 RBT

2010

DISTRIBUTED MEDIA / LEARNING STREET

RBT CPT4

CLOSET

CORRIDOR

2010B

2033

CPT4

G

STAIR R&D 2045

2010A

P1 F23

ISC

AP SEC'Y

ASSISTANT PRINCIPAL

2038

2038A

RBT

SMALL GROUP ELEC SC

CPT4

2040

DISTRIBUTED MEDIA / LEARNING STREET

DISTRIBUTED MEDIA / LEARNING STREET

2029

2029

P7

VCT1

P7

CPT4

CLASSROOM 2026

F7

CORRIDOR

J

P7

STAIR SC

ST-03.2

P1 F23

P7

P7

C

CPT4

SP ED OFFICE

WAITING

2016

2018A

GUIDANCE 2018

xF CPT4

P7

CPT4

STAFF DEVELOPMENT

VESTIBULE F24

2049

WOMEN'S TOILET

2042A

VCT3

2042

P1 F23

CPT1

xE

CPT4

2032

2036

P1 F23

C

ISSUED FOR CONSTRUCTION

xD

CPT5

2014

CORRIDOR

VCT7

P7

CPT4

H

xC

2012

STOR

CPT4 SC

P7

CPT7

CPT5

CPT4

F8

2030

2025

TLT

VCT3

ST-02.2

CORRIDOR

CPT4

A12-16

21

CLASSROOM

CLASSROOM

CLASSROOM

2020

2022

2024

ITEM

#

DATE

DESCRIPTION

F14

DATA SC

2044

T15

JAN F16

P7

2046

MEN'S TOILET

CORRIDOR 2037

2048

VESTIBULE OFFICE

OFFICE

2049D

2049A

F24

HALL

F14

xG

2048A

P1 F23

P1 F22 CPT1

K

FINISH PLAN GENERAL NOTES:

OFFICE

OFFICE

2049C

2049B

SCIENCE

A12-14

CPT1

CPT1

VCT1 ISC P1 F22 P3

P1 F22

FLOOR FINISH LEGEND:

DESIGN DRAWINGS ONLY. CONTRACTOR TO VERIFY ALL APPROPRIATE INSTALLATION AND CONSTRUCTINO DETAILS AND ABILITY TO INSTALL PER DESIGN INTENT. PLEASE VERIFY ANY QUESTIONS AND/OR DESCREPANCIES WITH LBA INTERIORS PRIOR TO CONSTRUCTION.

2.

CARPET INSTALLATION SHALL COMPLY WITH THE WORKMANSHIP GUIDELINES AS PUBLISHED BY THE AMERICAN CARPET INSTITUTES LATEST EDITION AND SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, PROVIDING AN ATTRACTIVE WRINKLE FREE APPEARANCE. CARPET SEAMS SHALL BE BUTT MATCHED RUNNING IN THE SAME DIRECTION. PROVIDE SEAMING DIAGRAM FOR APPROVAL BY LBA INTERIORS.

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

CPT

CPT

3. 4.

FLASH-PATCH / FLOOR STONE ALL AREAS WHERE FLOOR IS NOT LEVEL OR TRUE PRIOR TO FLOORING INSTALLATION. GENERAL CONTRACTOR TO SCRAPE EXISTING SLAB FREE OF SCREWS, ADHESIVE AND OTHER MISCELLANEOUS MATERIALS FOR A SMOOTH EVEN FINISH.

WOM

WALK-OFF MAT

5.

RB

RUBBER BASE

6.

ALL CARPET TO CARPET AND CARPET TO TILE TRANSITIONS ARE TO BE LEVEL W/SEAMS TIGHTLY BUTTED. FLOAT FLOOR OR PROVIDE UNDERLAYMENT AS NECESSARY ; RE: INTERIOR FINISH SPECS. CENTER FLOORING TRANSITIONS UNDER DOOR UNLESS OTHERWISE POSTED.

7.

ALL ROOMS TO BE PAINTED P1 UNLESS NOTED OTHERWISE

8.

ALL WALL OR CEILING GRILLS, GRATES, ACCESS PANELS TO RECIEVE THE WALL FINISH DIRECLTY ADJACENT. FOR WALLS, IF THE FINISH IS WALL VINYL, PLEASE PAINT TO MATCH WALL VINYL: INTERIOR DESIGNER TO SELECT COLOR. ALL ELECTRICAL SWITCH AND PLUG PLATES FINISHES TO BE DETERMINED; G.C. TO PROVIDE ALL COLOR OPTIONS TO LBA INTERIORS FOR FINAL COLOR SELECTION CORNER GUARDS ON OUTSIDE CORNERS IN PUBLIC AREAS, UNLESS OTHERWISE NOTED. RE: INTERIOR FINISH SCHEDULE FOR CORNER GUARD TO MATCH PAINT SELECTION. ALL ROOMS W/FRP TO BE FULL HEIGHT UNLESS OTHERWISE NOTED

9. 10. 11.

VINYL COMPOSITION TILE

SC

SEALED CONCRETE

HSC

HARDENED SEALED CONCRETE

ISC

INTEGRAL COLOR SEALED CONCRETE

SSC

SLIP RESISTANT, TINTED SEALED CONCRETE RUBBER TREAD

13.

ALL RUBBER BASE TO BE RB1, UNLESS OTHERWISE NOTED

LT

LANDING TREAD

E

EPOXY

TRANSITION

COLOR

FLOOR TO FLOOOR MATERIAL

JOHNSONITE SLT-XX-A

TBD

RBT to WOM; CPT to VCT; WOM to VCT; WOM to SV; SV to CPT; RBT to CPT

JOHNSONITE SLT-XX-B

TBD

VCT to RBT

AS VCT

ISC

WD

PREP

P1 F22

2050A

ISC

N.2 P3 P3

N.5 PREP

ISC

JOHNSONITE RRS-XX-C TBD

VCT to HSC; VCT to SC; VCT to ISC; SV to SC; SV to WD

JOHNSONITE EG-XX-H

TBD

ALL CONCRETE to CPT

SCHLUTER-SCHIENE

TBD

CPT to T; VCT to E; SV to E

SCHLUTER-RENO U

TBD

VCT to T; SV to T

SCHLUTER-RENO V

TBD

SSC to T

SCHUTER-HKU

TBD

WT to SV

FLOAT FLOOR

N/A

SV to VCT

N/A

N/A

WD to SC (SLAB IS DEPRESSED)

RT RWD

7

F3

CPT 4 P1, RB1 - SIDE WALLS P5, RB5 - TEACHING WALL F10 T3 (WALL & FLOOR) T3.1 P9, RB9 - BACK WALL TR1 P1 CPT 4 P1 - SIDE WALLS F11 T3 (WALL & FLOOR) P9 - BACK WALL T3.1 P7 - TEACHING WALL TR1 RB1 T5 T9 T1 (WALL) P1 T1.1 TR1 F12 T3 (WALL & FLOOR) SSC (FLOOR) T3.1 TR1 WOM T4 T1 T9 TR1 P1 T6 T6.1 P1

F4

WOOD F6

RECLAIMED WOOD PLANKS

X X

FINISH MATERIAL ABOVE FINISH MATERIAL BELOW

X

SINGLE FULL HEIGHT WALL FINISH MATERIAL

F15 T3 (WALL & FLOOR) T3.1 TR1 T8 T9 P1

F21 T1 TR1 T6 T6.1

F22 T1 TR1 SC F16 T8 RB1 T 8.1 P1 FRP FROM FINISHED FLOOR 48" ON (2) WET WALLS F17 EPOXY INTEGRAL BASE P1

T1 F18 TR1 T5 T5.1

Key Plan:

5.2

PAINT

T

TILE

U

UPHOLSTERY, VERTICAL APPLICATION

STV

F23 T1 TR1 T7 T 7.1

3

2

F

D

B

F24 T3 (WALL & FLOOR) T3.1 TR1

A

LBA Project Date

NORTH

STONE VENEER

1/8" = 1'-0" 4

E C

RECLAIMED WOOD PLANKS

P

G

2012.32 15 JANUARY 2014

ADD ALTERNATE - EPOXY

CORNER GUARD

5

Seal:

A

SECOND LEVEL FLOOR FINISH PLAN - AREA B 6

B

ADD ALTERNATE OPTIONS: 1

P

1

CPT 2 P1, RB1 - SIDE WALLS P3, RB3 - BACK WALL P9, RB9 - TEACHING WALL F9

ANTI STATIC VCT

RUBBER TILE

T1 F13 T3 (WALL & FLOOR) F19 TR1 TR1 T4 T3.1 T4.1 T6 T7 (FLOOR & WALL) T9 T7.1 P1 T7.2 P1 F14 T3 (WALL & FLOOR) F20 T1 TR1 TR1 T3.1 T10 T2 (FLOOR) T7 T10.1 T1 (WALL) T9 TR1 P1 T1.1 VCT 1 RB1 P1

F2

F5

SHEET VINYL

WALL FINISH LEGEND:

RWD

7

CPT 2 F7 P1, RB1 - SIDE WALLS P3, RB3 - TEACHING WALL P9, RB9 - BACK WALL

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

ISC

8

F1

F8

VCT

SV

FINISH GROUP LEGEND:

TILE

ALL GYP. CEILINGS TO BE P2, UNLESS OTHERWISE NOTED

FLOOR TRANSITION MATRIX

N

T

FLOOR FINISH DESIGNATION

12. P3

2051

X

RBT

SCIENCE

2051A

1

1.

2050

M

A

2

P3

L

23

3

CPT1

2049E

B

4

K.6

1

SECOND LEVEL FINISH PLAN - AREA B

A13-22B


7

6

5

4

3

2

1

Lantz-Boggio Architects, P.C.

FINISH PLAN GENERAL NOTES:

7

8

F

6.3

x9

DESIGN DRAWINGS ONLY. CONTRACTOR TO VERIFY ALL APPROPRIATE INSTALLATION AND CONSTRUCTION DETAILS AND ABILITY TO INSTALL PER DESIGN INTENT. PLEASE VERIFY ANY QUESTIONS AND/OR DESCREPANCIES WITH LBA INTERIORS PRIOR TO CONSTRUCTION

Ph: 303.773.0436 | Fax: 303.773.8709

2.

CARPET INSTALLATION SHALL COMPLY WITH THE WORKMANSHIP GUIDELINES AS PUBLISHED BY THE AMERICAN CARPET INSTITUTES LATEST EDITION AND SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, PROVIDING AN ATTRACTIVE WRINKLE FREE APPEARANCE. CARPET SEAMS SHALL BE BUTT MATCHED RUNNING IN THE SAME DIRECTION. PROVIDE SEAMING DIAGRAM FOR APPROVAL BY LBA INTERIORS

IN ASSOCIATION WITH:

3. 4.

FLASH-PATCH / FLOOR STONE ALL AREAS WHERE FLOOR IS NOT LEVEL OR TRUE PRIOR TO FLOORING INSTALLATION GENERAL CONTRACTOR TO SCRAPE EXISTING SLAB FREE OF SCREWS, ADHESIVE AND OTHER MISCELLANEOUS MATERIALS FOR A SMOOTH EVEN FINISH

5. 6.

ALL CARPET TO CARPET AND CARPET TO TILE TRANSITIONS ARE TO BE LEVEL W/SEAMS TIGHTLY BUTTED. FLOAT FLOOR OR PROVIDE UNDERLAYMENT AS NECESSARY ; RE: ARCHITECTURAL FINISH SPECS CENTER FLOORING TRANSITIONS UNDER DOOR UNLESS OTHERWISE POSTED

7.

ALL ROOMS TO BE PAINTED P1 UNLESS NOTED OTHERWISE

8.

ALL WALL OR CEILING GRILLS, GRATES, ACCESS PANELS TO RECEIVE THE WALL FINISH DIRECLTY ADJACENT

9.

ALL ELECTRICAL SWITCH AND PLUG PLATES FINISHES TO BE DETERMINED; G.C. TO PROVIDE ALL COLOR OPTIONS TO LBA INTERIORS FOR FINAL COLOR SELECTION

10.

CORNER GUARDS ON OUTSIDE CORNERS IN PUBLIC AREAS, UNLESS OTHERWISE NOTED. RE: INTERIOR FINISH SCHEDULE FOR CORNER GUARD TO MATCH PAINT SELECTION

11.

ALL ROOMS W/FRP TO BE FULL HEIGHT UNLESS OTHERWISE NOTED

NEW LARAMIE HIGH SCHOOL

12.

ALL GYP. CEILINGS TO BE P2, UNLESS OTHERWISE NOTED

Laramie | Wyoming

13.

ALL RUBBER BASE TO BE RB1 UNLESS OTHERWISE NOTED

FLOOR FINISH LEGEND: X NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

1.

FLOOR FINISH DESIGNATION

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

OPEN TO BELOW

CPT

WOM

WALK-OFF MAT

RB

RUBBER BASE

T

xEE

PP E

F2

TILE

VCT

VINYL COMPOSITION TILE

SC

SEALED CONCRETE

HSC

HARDENED SEALED CONCRETE

ISC

INTEGRAL COLOR SEALED CONCRETE

SSC

SLIP RESISTANT, TINTED SEALED CONCRETE

RBT

RUBBER TREAD

LT

LANDING TREAD

E

EPOXY

SV

F3

F4

F5

SHEET VINYL

OPEN TO BELOW AS VCT

ANTI STATIC VCT

WD

WOOD

RT

RUBBER TILE

RWD

CPT 2 F7 P1, RB1 - SIDE WALLS P3, RB3 - TEACHING WALL P9, RB9 - BACK WALL F8

CPT

F6

RECLAIMED WOOD PLANKS

WALL FINISH LEGEND: X X

FINISH MATERIAL ABOVE FINISH MATERIAL BELOW

X

SINGLE FULL HEIGHT WALL FINISH MATERIAL

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

FINISH GROUP LEGEND: F1

CPT 2 P1, RB1 - SIDE WALLS P3, RB3 - BACK WALL P9, RB9 - TEACHING WALL F9

VCT 1 RB1 P1 T7 (FLOOR & WALL) T7.1 T7.2 P1 T2 (FLOOR) T1 (WALL) TR1 T1.1

CPT 4 P1, RB1 - SIDE WALLS P5, RB5 - TEACHING WALL F10 T3 (WALL & FLOOR) T3.1 P9, RB9 - BACK WALL TR1 P1 CPT 4 P1 - SIDE WALLS F11 T3 (WALL & FLOOR) P9 - BACK WALL T3.1 P7 - TEACHING WALL TR1 RB1 T5 T9 T1 (WALL) P1 T1.1 TR1 F12 T3 (WALL & FLOOR) SSC (FLOOR) T3.1 TR1 WOM T4 T1 T9 TR1 P1 T6 T6.1 P1

T1 F13 T3 (WALL & FLOOR) F19 TR1 TR1 T4 T3.1 T4.1 T6 T9 P1

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

F14 T3 (WALL & FLOOR) F20 T1 TR1 TR1 T3.1 T10 T7 T10.1 T9 P1 F15 T3 (WALL & FLOOR) T3.1 TR1 T8 T9 P1

T1 F18 TR1 T5 T5.1

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

F21 T1 TR1 T6 T6.1 F22 T1 TR1 T8 T 8.1

F16 SC RB1 P1 FRP FROM FINISHED FLOOR 48" ON (2) WET WALLS F17 EPOXY INTEGRAL BASE P1

E

F23 T1 TR1 T7 T 7.1 F24 T3 (WALL & FLOOR) T3.1 TR1

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

ADD ALTERNATE - EPOXY FLOOR TRANSITION MATRIX

MM.9 MM.6 OPEN TO BELOW

MM

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION:

FLOOR TO FLOOOR MATERIAL

JOHNSONITE SLT-XX-A

TBD

RBT to WOM; CPT to VCT; WOM to VCT; WOM to SV; SV to CPT; RBT to CPT

JOHNSONITE SLT-XX-B

TBD

VCT to RBT

JOHNSONITE EG-XX-H

TBD

ALL CONCRETE to CPT

RECLAIMED WOOD PLANKS

SCHLUTER-SCHIENE

TBD

CPT to T; VCT to E; SV to E

P

PAINT

SCHLUTER-RENO U

TBD

VCT to T; SV to T

T

TILE

SCHLUTER-RENO V

TBD

SSC to T

U

UPHOLSTERY, VERTICAL APPLICATION

SCHUTER-HKU

TBD

WT to SV

STONE VENEER

FLOAT FLOOR

N/A

SV to VCT

CORNER GUARD

N/A

N/A

WD to SC (SLAB IS DEPRESSED)

STV

D

COLOR

VCT to HSC; VCT to SC; VCT to ISC; SV to SC; SV to WD

RWD

LL

TRANSITION

JOHNSONITE RRS-XX-C TBD

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

ADD ALTERNATE OPTIONS: 1

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187 Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

D

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

OPEN TO BELOW

KK JJ.7

x9.3

x9.2

ISSUED FOR CONSTRUCTION HH.3

STAIR VCT1

ST-07.2

HH GG.3

P6

C

C

HH.4

P1 F21

ITEM

FF

DATE

DESCRIPTION

MEDIA CENTER CONFERENCE/ CLASSROOM

P6

REFER TO TH SERIES DRAWINGS FOR FINISHES AT THEATER

2100

AV STOR

EE

#

CPT6

2103 P1 F21

VCT1

CORRIDOR 2001

DD

OFFICE/ WORKROOM

CPT1

2101

B

B

Seal:

A12-16

7 T1 T6

BB.5

P6

10

P1 F21

BB

RWD P6

Key Plan: G

E

F

D

C

F21

MEN'S TOILET

WOMEN'S TOILET

2123

2121

B

F21

CONFERENCE

9 A

P1 F21

AA.1

2104

P6

P6

RBT

P6

P1 F21

P1 F21

A

CPT6

AA.1 A

LBA Project Date

RBT

A

11

A

2012.32 15 JANUARY 2014

SECOND LEVEL FINISH PLAN - AREA C

6

8

NORTH

1 7

A13-22C

SECOND LEVEL FLOOR FINISH PLAN - AREA C 1/8" = 1'-0" 6

5

4

3

2

1


7

6

5

4

3

2

1

FINISH PLAN GENERAL NOTES:

F

16.4

16

13.1 12.9

11.6

1.

DESIGN DRAWINGS ONLY. CONTRACTOR TO VERIFY ALL APPROPRIATE INSTALLATION AND CONSTRUCTION DETAILS AND ABILITY TO INSTALL PER DESIGN INTENT. PLEASE VERIFY ANY QUESTIONS AND/OR DESCREPANCIES WITH LBA INTERIORS PRIOR TO CONSTRUCTION

2.

CARPET INSTALLATION SHALL COMPLY WITH THE WORKMANSHIP GUIDELINES AS PUBLISHED BY THE AMERICAN CARPET INSTITUTES LATEST EDITION AND SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, PROVIDING AN ATTRACTIVE WRINKLE FREE APPEARANCE. CARPET SEAMS SHALL BE BUTT MATCHED RUNNING IN THE SAME DIRECTION. PROVIDE SEAMING DIAGRAM FOR APPROVAL BY LBA INTERIORS

3. 4.

FLASH-PATCH / FLOOR STONE ALL AREAS WHERE FLOOR IS NOT LEVEL OR TRUE PRIOR TO FLOORING INSTALLATION GENERAL CONTRACTOR TO SCRAPE EXISTING SLAB FREE OF SCREWS, ADHESIVE AND OTHER MISCELLANEOUS MATERIALS FOR A SMOOTH EVEN FINISH

5. 6.

ALL CARPET TO CARPET AND CARPET TO TILE TRANSITIONS ARE TO BE LEVEL W/SEAMS TIGHTLY BUTTED. FLOAT FLOOR OR PROVIDE UNDERLAYMENT AS NECESSARY ; RE: ARCHITECTURAL FINISH SPECS CENTER FLOORING TRANSITIONS UNDER DOOR UNLESS OTHERWISE POSTED

7.

ALL ROOMS TO BE PAINTED P1 UNLESS NOTED OTHERWISE

8.

ALL WALL OR CEILING GRILLS, GRATES, ACCESS PANELS TO RECEIVE THE WALL FINISH DIRECLTY ADJACENT

9.

ALL ELECTRICAL SWITCH AND PLUG PLATES FINISHES TO BE DETERMINED; G.C. TO PROVIDE ALL COLOR OPTIONS TO LBA INTERIORS FOR FINAL COLOR SELECTION

10.

CORNER GUARDS ON OUTSIDE CORNERS IN PUBLIC AREAS, UNLESS OTHERWISE NOTED. RE: INTERIOR FINISH SCHEDULE FOR CORNER GUARD TO MATCH PAINT SELECTION

11.

ALL ROOMS W/FRP TO BE FULL HEIGHT UNLESS OTHERWISE NOTED

12.

ALL GYP. CEILINGS TO BE P2, UNLESS OTHERWISE NOTED

13.

ALL RUBBER BASE TO BE RB1 UNLESS OTHERWISE NOTED

FLOOR FINISH LEGEND: X

FLOOR FINISH DESIGNATION

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

CPT

WOM

WALK-OFF MAT

RB

RUBBER BASE

T

F1

JJ.7

SEALED CONCRETE

F3

HSC

HARDENED SEALED CONCRETE

ISC

INTEGRAL COLOR SEALED CONCRETE

SSC

SLIP RESISTANT, TINTED SEALED CONCRETE

RBT

RUBBER TREAD

LT

LANDING TREAD

E

EPOXY

AS VCT

JJ

TILE

SC

SV

E

F2

VINYL COMPOSITION TILE

ANTI STATIC VCT

WD

WOOD

RT

RUBBER TILE

RWD

F4

F5

SHEET VINYL

F6

RECLAIMED WOOD PLANKS

WALL FINISH LEGEND: WEST MECHANICAL ROOM

X X

FINISH MATERIAL ABOVE FINISH MATERIAL BELOW

CPT 2 F7 P1, RB1 - SIDE WALLS P3, RB3 - TEACHING WALL P9, RB9 - BACK WALL

X

SINGLE FULL HEIGHT WALL FINISH MATERIAL

CPT 2 P1, RB1 - SIDE WALLS P3, RB3 - BACK WALL P9, RB9 - TEACHING WALL F9

Laramie | Wyoming

T7 (FLOOR & WALL) T7.1 T7.2 P1 T2 (FLOOR) T1 (WALL) TR1 T1.1

T1 F13 T3 (WALL & FLOOR) F19 TR1 TR1 T4 T3.1 T4.1 T6 T9 P1

F15 T3 (WALL & FLOOR) T3.1 TR1 T8 T9 P1

F17 EPOXY INTEGRAL BASE P1

T1 F18 TR1 T5 T5.1

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

F22 T1 TR1 T8 T 8.1

F23 T1 TR1 T7 T 7.1

E

F24 T3 (WALL & FLOOR) T3.1 TR1

COLOR

FLOOR TO FLOOOR MATERIAL

JOHNSONITE SLT-XX-A

TBD

RBT to WOM; CPT to VCT; WOM to VCT; WOM to SV; SV to CPT; RBT to CPT

JOHNSONITE SLT-XX-B

TBD

VCT to RBT VCT to HSC; VCT to SC; VCT to ISC; SV to SC; SV to WD

JOHNSONITE EG-XX-H

TBD

ALL CONCRETE to CPT

RECLAIMED WOOD PLANKS

SCHLUTER-SCHIENE

TBD

CPT to T; VCT to E; SV to E

P

PAINT

SCHLUTER-RENO U

TBD

VCT to T; SV to T

SCHLUTER-RENO V

TBD

SSC to T

U

UPHOLSTERY, VERTICAL APPLICATION

SCHUTER-HKU

TBD

WT to SV

1167

STV

STONE VENEER

FLOAT FLOOR

N/A

SV to VCT

CORNER GUARD

N/A

N/A

WD to SC (SLAB IS DEPRESSED)

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094 Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

TRANSITION

TILE

EAST MECHANICAL ROOM

F21 T1 TR1 T6 T6.1

ADD ALTERNATE - EPOXY

T

EE.2

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

F16 SC RB1 P1 FRP FROM FINISHED FLOOR 48" ON (2) WET WALLS

COMPETITION GYM

D

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

F14 T3 (WALL & FLOOR) F20 T1 TR1 TR1 T3.1 T10 T7 T10.1 T9 P1

JOHNSONITE RRS-XX-C TBD

RWD

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

NEW LARAMIE HIGH SCHOOL

FLOOR TRANSITION MATRIX

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION:

SC

IN ASSOCIATION WITH:

ADD ALTERNATE OPTIONS:

GG.3 GG

VCT 1 RB1 P1

CPT 4 P1, RB1 - SIDE WALLS P5, RB5 - TEACHING WALL F10 T3 (WALL & FLOOR) T3.1 P9, RB9 - BACK WALL TR1 P1 CPT 4 P1 - SIDE WALLS F11 T3 (WALL & FLOOR) P9 - BACK WALL T3.1 P7 - TEACHING WALL TR1 RB1 T5 T9 T1 (WALL) P1 T1.1 TR1 F12 T3 (WALL & FLOOR) SSC (FLOOR) T3.1 TR1 WOM T4 T1 T9 TR1 P1 T6 T6.1 P1

1

2194

Ph: 303.773.0436 | Fax: 303.773.8709

FINISH GROUP LEGEND:

F8

VCT

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

F

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

CPT

Lantz-Boggio Architects, P.C.

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187 Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

D

EE

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

2197 HSC

CC

ISSUED FOR CONSTRUCTION BB.5

SC

C

C

AA

P1 F21

AA.1

A

P6

ITEM

#

DATE

DESCRIPTION

AA.1 A

CPT1

CORRIDOR

CPT1

CPT1

2002

B

x x14 xCC xBB A12-16 VCT1

B

B

35

OPEN TO BELOW

Seal:

xAA P1 F21

xA

CORRIDOR 2002

Key Plan:

C.8

G

E

F

D

C SC

D

B

D.5

A

LBA Project Date

E A

A

15.9

15

14.2

13

2012.32 15 JANUARY 2014

SECOND LEVEL FINISH PLAN - AREA D

NORTH

1 7

A13-22D

SECOND LEVEL FINISH PLAN - AREA D 1/8" = 1'-0" 6

5

4

3

2

1


7

6

5

4

3

2

1

Lantz-Boggio Architects, P.C.

FINISH PLAN GENERAL NOTES:

22

1.

DESIGN DRAWINGS ONLY. CONTRACTOR TO VERIFY ALL APPROPRIATE INSTALLATION AND CONSTRUCTION DETAILS AND ABILITY TO INSTALL PER DESIGN INTENT. PLEASE VERIFY ANY QUESTIONS AND/OR DESCREPANCIES WITH LBA INTERIORS PRIOR TO CONSTRUCTION

2.

CARPET INSTALLATION SHALL COMPLY WITH THE WORKMANSHIP GUIDELINES AS PUBLISHED BY THE AMERICAN CARPET INSTITUTES LATEST EDITION AND SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, PROVIDING AN ATTRACTIVE WRINKLE FREE APPEARANCE. CARPET SEAMS SHALL BE BUTT MATCHED RUNNING IN THE SAME DIRECTION. PROVIDE SEAMING DIAGRAM FOR APPROVAL BY LBA INTERIORS

3. 4.

FLASH-PATCH / FLOOR STONE ALL AREAS WHERE FLOOR IS NOT LEVEL OR TRUE PRIOR TO FLOORING INSTALLATION GENERAL CONTRACTOR TO SCRAPE EXISTING SLAB FREE OF SCREWS, ADHESIVE AND OTHER MISCELLANEOUS MATERIALS FOR A SMOOTH EVEN FINISH

5. 6.

ALL CARPET TO CARPET AND CARPET TO TILE TRANSITIONS ARE TO BE LEVEL W/SEAMS TIGHTLY BUTTED. FLOAT FLOOR OR PROVIDE UNDERLAYMENT AS NECESSARY ; RE: ARCHITECTURAL FINISH SPECS CENTER FLOORING TRANSITIONS UNDER DOOR UNLESS OTHERWISE POSTED

LOBBY

7.

ALL ROOMS TO BE PAINTED P1 UNLESS NOTED OTHERWISE

2199

8.

ALL WALL OR CEILING GRILLS, GRATES, ACCESS PANELS TO RECEIVE THE WALL FINISH DIRECLTY ADJACENT

9.

ALL ELECTRICAL SWITCH AND PLUG PLATES FINISHES TO BE DETERMINED; G.C. TO PROVIDE ALL COLOR OPTIONS TO LBA INTERIORS FOR FINAL COLOR SELECTION

10.

CORNER GUARDS ON OUTSIDE CORNERS IN PUBLIC AREAS, UNLESS OTHERWISE NOTED. RE: INTERIOR FINISH SCHEDULE FOR CORNER GUARD TO MATCH PAINT SELECTION

11.

ALL ROOMS W/FRP TO BE FULL HEIGHT UNLESS OTHERWISE NOTED

12.

ALL GYP. CEILINGS TO BE P2, UNLESS OTHERWISE NOTED

13.

ALL RUBBER BASE TO BE RB1 UNLESS OTHERWISE NOTED

18

17.2

16.4

16

STAIR ST-12.2 F

STAIR

VCT1

ST-14.2

STORAGE

FLOOR FINISH LEGEND:

2188A

NN

POOL CONTROL ROOM

VCT1

MM.6

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

2190

X

CPT

CPT

WOM

WALK-OFF MAT

RB

RUBBER BASE

LL

F2

TILE VINYL COMPOSITION TILE

SC

SEALED CONCRETE

F3

HSC

HARDENED SEALED CONCRETE

ISC

INTEGRAL COLOR SEALED CONCRETE

SSC

SLIP RESISTANT, TINTED SEALED CONCRETE

RBT

RUBBER TREAD

LT

LANDING TREAD

E

EPOXY

SV

E

F1

AS VCT

ANTI STATIC VCT WOOD

RT

RUBBER TILE

RWD

F4

F5

SHEET VINYL

WD

F6

RECLAIMED WOOD PLANKS

WALL FINISH LEGEND: X X

CPT 2 F7 P1, RB1 - SIDE WALLS P3, RB3 - TEACHING WALL P9, RB9 - BACK WALL F8

VCT

FINISH MATERIAL ABOVE FINISH MATERIAL BELOW

CPT 2 P1, RB1 - SIDE WALLS P3, RB3 - BACK WALL P9, RB9 - TEACHING WALL F9

X

VCT 1 RB1 P1 T7 (FLOOR & WALL) T7.1 T7.2 P1 T2 (FLOOR) T1 (WALL) TR1 T1.1

CPT 4 P1, RB1 - SIDE WALLS P5, RB5 - TEACHING WALL F10 T3 (WALL & FLOOR) T3.1 P9, RB9 - BACK WALL TR1 P1 CPT 4 P1 - SIDE WALLS F11 T3 (WALL & FLOOR) P9 - BACK WALL T3.1 P7 - TEACHING WALL TR1 RB1 T5 T9 T1 (WALL) P1 T1.1 TR1 F12 T3 (WALL & FLOOR) SSC (FLOOR) T3.1 TR1 WOM T4 T1 T9 TR1 P1 T6 T6.1 P1

IN ASSOCIATION WITH:

NEW LARAMIE HIGH SCHOOL Laramie | Wyoming

T1 F13 T3 (WALL & FLOOR) F19 TR1 TR1 T4 T3.1 T4.1 T6 T9 P1

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

F14 T3 (WALL & FLOOR) F20 T1 TR1 TR1 T3.1 T10 T7 T10.1 T9 P1

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

F15 T3 (WALL & FLOOR) T3.1 TR1 T8 T9 P1

F21 T1 TR1 T6 T6.1

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

F22 T1 TR1 T8 T 8.1

F16 SC RB1 P1 FRP FROM FINISHED FLOOR 48" ON (2) WET WALLS F17 EPOXY INTEGRAL BASE P1

T1 F18 TR1 T5 T5.1

E

F23 T1 TR1 T7 T 7.1

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

ADD ALTERNATE - EPOXY FLOOR TRANSITION MATRIX

WEST MECHANICAL ROOM 2194 HSC

GG SC

COLOR

FLOOR TO FLOOOR MATERIAL

JOHNSONITE SLT-XX-A

TBD

RBT to WOM; CPT to VCT; WOM to VCT; WOM to SV; SV to CPT; RBT to CPT

JOHNSONITE SLT-XX-B

TBD

VCT to RBT VCT to HSC; VCT to SC; VCT to ISC; SV to SC; SV to WD

JOHNSONITE EG-XX-H

TBD

ALL CONCRETE to CPT

RECLAIMED WOOD PLANKS

SCHLUTER-SCHIENE

TBD

CPT to T; VCT to E; SV to E

P

PAINT

SCHLUTER-RENO U

TBD

VCT to T; SV to T

T

TILE

SCHLUTER-RENO V

TBD

SSC to T

U

UPHOLSTERY, VERTICAL APPLICATION

SCHUTER-HKU

TBD

WT to SV

STONE VENEER

FLOAT FLOOR

N/A

SV to VCT

CORNER GUARD

N/A

N/A

WD to SC (SLAB IS DEPRESSED)

STV HSC

TRANSITION

JOHNSONITE RRS-XX-C TBD

RWD

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

F24 T3 (WALL & FLOOR) T3.1 TR1

SINGLE FULL HEIGHT WALL FINISH MATERIAL

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION:

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

ADD ALTERNATE OPTIONS: 1

JJ

Ph: 303.773.0436 | Fax: 303.773.8709

FINISH GROUP LEGEND:

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

T

LL.5

FLOOR FINISH DESIGNATION

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187 Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

D

D

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

HSC

POOL BLEACHERS 2195

EE.2

ISSUED FOR CONSTRUCTION

CC C

C

SC

STORAGE

ITEM

#

DATE

DESCRIPTION

2193

AA

A

A RBT CPT1

B

CPT1

B

B

Seal: RBT

C OPEN TO BELOW

Key Plan: G

E

F

D

C

C.5 B

A

LBA Project Date

C.8 A

A

21

20

19

17.9

17

15.9

2012.32 15 JANUARY 2014

SECOND LEVEL FINISH PLAN - AREA F

NORTH

A13-22F

SECOND LEVEL FINISH PLAN - AREA F

1

1/8" = 1'-0" 7

6

5

4

3

2

1


7

6

5

4

3

2

1

Lantz-Boggio Architects, P.C.

FINISH PLAN GENERAL NOTES:

F

1.

DESIGN DRAWINGS ONLY. CONTRACTOR TO VERIFY ALL APPROPRIATE INSTALLATION AND CONSTRUCTION DETAILS AND ABILITY TO INSTALL PER DESIGN INTENT. PLEASE VERIFY ANY QUESTIONS AND/OR DESCREPANCIES WITH LBA INTERIORS PRIOR TO CONSTRUCTION

2.

CARPET INSTALLATION SHALL COMPLY WITH THE WORKMANSHIP GUIDELINES AS PUBLISHED BY THE AMERICAN CARPET INSTITUTES LATEST EDITION AND SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, PROVIDING AN ATTRACTIVE WRINKLE FREE APPEARANCE. CARPET SEAMS SHALL BE BUTT MATCHED RUNNING IN THE SAME DIRECTION. PROVIDE SEAMING DIAGRAM FOR APPROVAL BY LBA INTERIORS

3. 4.

FLASH-PATCH / FLOOR STONE ALL AREAS WHERE FLOOR IS NOT LEVEL OR TRUE PRIOR TO FLOORING INSTALLATION GENERAL CONTRACTOR TO SCRAPE EXISTING SLAB FREE OF SCREWS, ADHESIVE AND OTHER MISCELLANEOUS MATERIALS FOR A SMOOTH EVEN FINISH

5. 6.

ALL CARPET TO CARPET AND CARPET TO TILE TRANSITIONS ARE TO BE LEVEL W/SEAMS TIGHTLY BUTTED. FLOAT FLOOR OR PROVIDE UNDERLAYMENT AS NECESSARY ; RE: ARCHITECTURAL FINISH SPECS CENTER FLOORING TRANSITIONS UNDER DOOR UNLESS OTHERWISE POSTED

7.

ALL ROOMS TO BE PAINTED P1 UNLESS NOTED OTHERWISE

8.

ALL WALL OR CEILING GRILLS, GRATES, ACCESS PANELS TO RECEIVE THE WALL FINISH DIRECLTY ADJACENT

9.

ALL ELECTRICAL SWITCH AND PLUG PLATES FINISHES TO BE DETERMINED; G.C. TO PROVIDE ALL COLOR OPTIONS TO LBA INTERIORS FOR FINAL COLOR SELECTION

10.

CORNER GUARDS ON OUTSIDE CORNERS IN PUBLIC AREAS, UNLESS OTHERWISE NOTED. RE: INTERIOR FINISH SCHEDULE FOR CORNER GUARD TO MATCH PAINT SELECTION

11.

ALL ROOMS W/FRP TO BE FULL HEIGHT UNLESS OTHERWISE NOTED

12.

ALL GYP. CEILINGS TO BE P2, UNLESS OTHERWISE NOTED

13.

ALL RUBBER BASE TO BE RB1 UNLESS OTHERWISE NOTED

FLOOR FINISH LEGEND: X

NOTICE: These documents are instruments of professional service, and information contained therein is incomplete unless used in conjunction with Lantz-Boggio's interpretations, decisions, observations and administrations. Use or reproduction of these documents in whole or in part without Lantz-Boggio's consent is in violation of common law, copyrights, statutory and other reserved rights. Refer to Act 17 U.S.C., par. 511 (1991), which preempts state and local public records act. Refer to Act 17 U.S.C., par 301 (1991).

WOM

WALK-OFF MAT

RB

RUBBER BASE

T

E

F2

TILE

VCT

VINYL COMPOSITION TILE

SC

SEALED CONCRETE

F3

HSC

HARDENED SEALED CONCRETE

ISC

INTEGRAL COLOR SEALED CONCRETE

SSC

SLIP RESISTANT, TINTED SEALED CONCRETE

RBT

RUBBER TREAD

LT

LANDING TREAD

E

EPOXY

SV AS VCT

F4

F5

SHEET VINYL ANTI STATIC VCT

WD

WOOD

RT

RUBBER TILE

RWD

F6

RECLAIMED WOOD PLANKS

WALL FINISH LEGEND: X X

CPT 2 F7 P1, RB1 - SIDE WALLS P3, RB3 - TEACHING WALL P9, RB9 - BACK WALL F8

CPT

CPT 2 P1, RB1 - SIDE WALLS P3, RB3 - BACK WALL P9, RB9 - TEACHING WALL F9

VCT 1 RB1 P1 T7 (FLOOR & WALL) T7.1 T7.2 P1 T2 (FLOOR) T1 (WALL) TR1 T1.1

CPT 4 P1, RB1 - SIDE WALLS P5, RB5 - TEACHING WALL F10 T3 (WALL & FLOOR) T3.1 P9, RB9 - BACK WALL TR1 P1 CPT 4 P1 - SIDE WALLS F11 T3 (WALL & FLOOR) P9 - BACK WALL T3.1 P7 - TEACHING WALL TR1 RB1 T5 T9 T1 (WALL) P1 T1.1 TR1 F12 T3 (WALL & FLOOR) SSC (FLOOR) T3.1 TR1 WOM T4 T1 T9 TR1 P1 T6 T6.1 P1

NEW LARAMIE HIGH SCHOOL

T1 F13 T3 (WALL & FLOOR) F19 TR1 TR1 T4 T3.1 T4.1 T6 T9 P1

Owner: Albany County School District One 1948 Grand Avenue Laramie | Wyoming 82070 Phone: 307.721.4400 Fax : 307.721.4408

F14 T3 (WALL & FLOOR) F20 T1 TR1 TR1 T3.1 T10 T7 T10.1 T9 P1

Quality Control: Pappas and Pappas Architects 2617 E.Lincolnway # A Cheyenne | Wyoming 82001 Phone: 307.637.5227 Fax : 307.755.0775

F15 T3 (WALL & FLOOR) T3.1 TR1 T8 T9 P1

F21 T1 TR1 T6 T6.1

Civil Engineer: DOWL HKM 1575 N.4th Street | Suite 105 Laramie | Wyoming 82072 Phone: 307.742.3816 Fax : 307.742.9741

F22 T1 TR1 SC F16 T8 RB1 T 8.1 P1 FRP FROM FINISHED FLOOR 48" ON (2) WET WALLS F17 EPOXY INTEGRAL BASE P1

T1 F18 TR1 T5 T5.1

E

F23 T1 TR1 T7 T 7.1

Landscape Architect: David Ohde and Associates 810 Randall Avenue Cheyenne | Wyoming 82001 Phone: 307.634.8804 Fax : 307.638.7978

ADD ALTERNATE - EPOXY FLOOR TRANSITION MATRIX

TRANSITION

COLOR

FLOOR TO FLOOOR MATERIAL

JOHNSONITE SLT-XX-A

TBD

RBT to WOM; CPT to VCT; WOM to VCT; WOM to SV; SV to CPT; RBT to CPT

JOHNSONITE SLT-XX-B

TBD

VCT to RBT

JOHNSONITE RRS-XX-C TBD

VCT to HSC; VCT to SC; VCT to ISC; SV to SC; SV to WD

JOHNSONITE EG-XX-H

TBD

ALL CONCRETE to CPT

RECLAIMED WOOD PLANKS

SCHLUTER-SCHIENE

TBD

CPT to T; VCT to E; SV to E

P

PAINT

SCHLUTER-RENO U

TBD

VCT to T; SV to T

T

TILE

SCHLUTER-RENO V

TBD

SSC to T

U

UPHOLSTERY, VERTICAL APPLICATION

SCHUTER-HKU

TBD

WT to SV

STONE VENEER

FLOAT FLOOR

N/A

SV to VCT

CORNER GUARD

N/A

N/A

WD to SC (SLAB IS DEPRESSED)

RWD

STV

Acoustics | Performing Arts | Technology: D.L. Adams Associates, Inc 1536 Ogden Street Denver | Colorado 80218 Phone: 303.455.1900 Fax : 303.455.9187 Food Service: William Caruso and Associates 8055 East Tufts Avenue | Suite 1320 Denver | Colorado 80237 Phone: 303.649.1600 Fax : 303.649.1660

D

D

22

18

17.2

16.4

Structural Engineer: Martin/Martin Wyoming 4020 Laramie Street Cheyenne | Wyoming 82001 Phone: 307.637.8422 Fax : 307.637.4022 Mechanical/Plumbing/Fire Protection/ Electrical Engineer: MKK Consulting Engineers, Inc 500 West 18th Street | Suite 200 Cheyenne | Wyoming 82001 Phone: 307.634.7647 Fax : 307.638.6094

F24 T3 (WALL & FLOOR) T3.1 TR1

SINGLE FULL HEIGHT WALL FINISH MATERIAL

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION:

330 North Wabash Ave Suite 3600, Chicago IL 60611 t 987.654.3210 f 012.345.6789 www.perkinswill.com

F

ADD ALTERNATE OPTIONS:

FINISH MATERIAL ABOVE FINISH MATERIAL BELOW

1 X

IN ASSOCIATION WITH:

FINISH GROUP LEGEND:

REFER TO ACHITECTURAL SPECIFICATIONS FOR PRODUCT SPECIFICATION

CPT

Ph: 303.773.0436 | Fax: 303.773.8709

Laramie | Wyoming F1

FLOOR FINISH DESIGNATION

5650 DTC Pkwy. | Suite 200 | Englewood | CO 80111

Aquatic Design: Aquatic Design Group 2226 Faraday Avenue Carlsbad | CA 92008 Phone: 760.444.8304

16

ISSUED FOR CONSTRUCTION WW

UU C

C

TT ITEM

#

DATE

DESCRIPTION

RR RBT

B

VCT1

B

STAIR

Seal:

ST-13.2

QQ STORAGE

VCT1

2196A

VCT1

VCT1

WRESTLING 2188

STAIR

Key Plan:

ST-12.2

G

E

F

D

LOBBY

C

2199

STAIR

VCT1

B

ST-14.2

A

STORAGE 2188A

NN

POOL CONTROL ROOM

LBA Project Date

VCT1

MM.6

2190 A

A

2012.32 15 JANUARY 2014

SECOND LEVEL FINISH PLAN - AREA G

NORTH

1 7

6

5

A13-23G

OVERALL LEVEL 02 FLOOR PLAN 1/8" = 1'-0" 4

3

2

1


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.