IS-II active Product Catalog
Contents IS-II active S.L.A. Surface
4
IS-II active Features
6
IS-II active Line up
8
IS-II active Flow Chart
10
IS Full Kit
12
IS Full Kit Components
13
IS-II active Drilling Sequence
15
IS-II active S.L.A. Surface S.L.A. (Sandblasting with Large grit and Acid etching)
IS-II active Surface
Macropore & Micropore
As making micropore in macropore, increasing contacted area with bone and helping blood mevement.
S.L.A. Surface
S.L.A.
SLA surface is the method that make rough surface by blasting on Machined implant suface with HA(HydroxyApatite) particle smaller than 50㎛, and oxidizing with acid. As making micropore in macropore, this makes increasing contacted area with bone(BIC ratio)m promoting cell’s activity. Shortening the contact time between bone and implant, reducing treatment period.
S.L.A. Surface Treatment Process Miling
Blasting
Acid Etching HA Powder
Machined
4
RBM
S.L.A.
IS-II active S.L.A. Surface S.L.A. Surface Roughness Stable and equal roughness / R.A 2.0
1,960 RA(㎛)
2,020 RA(㎛)
‘S’사 SLA Surface
Neobiotech S.L.A. Surface
S.L.A. Surface cell adhesion capability Comparing with Machined Surface and RBM Surface, It is reported that more cells adhered on Titanium Disk in S.L.A surface case.
Machined
RBM
S.L.A.
New bone formation measure of distance New bone formation measure of distance is longer in S.L.A surface cases comparing with RBM surface
RBM
신생골 형성 거리 Left : 1.976㎜ / Right : 2.35㎜
F : Fixture / BM : Bone Marrow
S.L.A.
신생골 형성 거리 Left : 2.460㎜ Right : 2.41㎜
F : Fixture / BM : Bone Marrow
5
IS-II active Features IS-II active is developed with many researchs and Knowhow from clinical studies for 10years. S.L.A. surface treatment - Fast and strong Osseointegration Bioseal heal on fixture upper part - Preventing of bone loss by increasing soft tissue attachment Magic threa & coronal macro thread - Strong primary stability BioSeal Increase sealing of soft tissue, and Minimize bone loss
Coronal Macro Thread Excellent primary stability at cortical bone.
Straight –Taper Body *Easy Drilling and implant insertion *Easy self compaction at soft bone
Magic Thread The body is specially designed to endure vertical vertical force and lateral pressure effectively.
Apex Powerful and well-defined threads exist at the peak of the apex. Drilling power is remarkable and initial fixation at the apex is excellent to both immediate placement and immediate loading.
S.L.A. Surface No impurities on implant surface(No residual acid and cell toxic) Optimal Rough Average(similar rough average with straumann SLA R.A)
BioSeal Application of machined surface & Micro groove on 0.5mm of upper part. Bioseal is unique design to minimize bone loss by maximizing sealing effect of soft tissue
Coronal Macro Thread CPowerful and well-defined threads exist at the peak of the apex. Drilling power is remarkable and initial fixation at the apex is excellent to both immediate placement and immediate loading.
Magic Thread Magic thread (Reversed thread type) is designed to resist strongly against occlusive force and lateral force in the long term. So,Operator can experience stable insertion and strong initial stability
6
IS-II active Features IS -II active Fixture Connection Conical Seal & Internal Hex structure 22∘
22∘ 0.4mm
- Group A : IS-II active all Narrow, Regular, Wide 7.3mm Fixture - Group B : IS-II active Regular, Wide 8.5, 10, 11.5, 13mm Fixture
Group A(Gray)
Group B(White)
IS-II active Fixture is compatible with all upper prosthetics of IS system When Prosthetics are connect to Group A, Prosthetics will be connected 0.4mm higher than Group B. * In order to increase strength of fixture body, Internal hex of Group A is designed 0.4mm higher than Group B.
Fixture Placement
Take out a package from outbox
Remove internal package
Connect Fixture with Driver
Remove the holder after connecing Fixture with Driver
Remove the back
Take out holder
7
IS-II active Fixture Line Up Narrow Ø 3.5 Ø 3.5
Actual Size
Length
Length(mm)
Code
8.5
BIS3508A
10
BIS3510A
11.5
BIS3511A
13
BIS3513A
Length(mm)
Code
7.3
BIS4007A
8.5
BIS4008A
10
BIS4010A
11.5
BIS4011A
13
BIS4013A
Length(mm)
Code
7.3
BIS4507A
8.5
BIS4508A
10
BIS4510A
11.5
BIS4511A
13
BIS4513A
Length(mm)
Code
7.3
BIS5007A
8.5
BIS5008A
10
BIS5010A
11.5
BIS5011A
13
BIS5013A
Ø 3.5
Regular Ø 4.0 Ø 3.7
Actual Size
Length
Ø 4.0
Regular Ø 4.5 Ø 3.9
Actual Size
Length
Ø 4.5
Wide Ø 5.0 Ø 4.4
Actual Size
Length
Ø 5.0
8
IS-II active Fixture Line Up S-wide Platform
Diameter(Ø)
Length
5.5
Platform(Ø)
4.5
Diameter
6.0
7.0
4.9
5.8
Length(mm)
Code
7.3
BIS5507A*
8.5
BIS5508A*
10
BIS5510A*
11.5
BIS5511A*
13
BIS5513A*
7.3
BIS6007A*
8.5
BIS6008A*
10
BIS6010A*
11.5
BIS6011A*
13
BIS6013A*
7.3
BIS7007A*
8.5
BIS7008A*
10
BIS7010A*
11.5
BIS7011A*
13
BIS7013A*
Length(mm)
Code
5.0
BIS5005A
6.0
BIS5006A
5.0
BIS5505A*
6.0
BIS5506A*
Short Platform
Length
7.3mm
Diameter(Ø)
Platform(Ø)
5.0
4.4
5.5
4.5
Diameter
S-wide Kit
* Additionally S-Wide Kit is needed to place S-wide Fixture and Ø 5.5 Short Fixture
9
IS-II active Prosthetic Flow Chart Solid Abutment
Plastic coping
Lab analog
Impression cap
1.2 Hex driver
Healing abutment
Solid abutment
Protective cap
Cover screw
1.2 Hex driver
IS-II active
10
IS-II active Prosthetic Flow Chart Cement & Screw Abutment
Straight
SCRP multi
Hex
R
Gold
SCRP multi
Hex
Non-hex Abutment positioner
Angled
R
Non-hex
CCM
Plastic coping
Hex
Non-hex
Shapable
Lab analog Hex
SCRP multi
R
SCRP multi
Non-hex
Hex
Non-hex
Non-hex
Lab analog
R
Pick up 1.2 Hex driver
Non-hex
Healing abutment
R
Plastic
Impression cap
Hex
SCRP multi
Hex
Transfer
Abutment positioner
Cover screw
IS-II active
1.2 Hex driver
Impression coping positioner
IS Full Kit Drill Extension
Surgical Drill
Point Lindemann
Stopper
Connector
Countersink
Profile Tap
Parallel Pin
Direction Pin
Fixture Driver
Hex Driver
Features of IS Full Kit 1. Easy Drill choice by simple Drilling Sequence and guideline on the Kit tray. Use drills sequentially when placing wide fixture.
Ex) When placing Ø4.5 Implant Ø2.5/LD Drill >> Ø2.2 Drill >> Ø2.9 Drill >> Ø3.4 Drill >> Ø3.9 Drill
2. Select Countersink or Profile Tap for IS, IS-II Fixture.
Ex) When placing IS Ø4.5 Implant Ø2.5/LD Drill >> Ø2.2 Drill >> Ø2.9 Drill >> Ø3.4 Drill >> Ø3.9 Drill >> Ø4.5 Counter Sink
Product lists which can be placed with IS Full Kit
IS
IS - II
IS - II active
※ Additionally S-wide Kit is needed when placing IS S-wide or IS-II S-wide Fixture
12
IS Full Kit Components Direction Pin
Surgical Drill Diameter
Code
Diameter
Code
Point Lindemann
LDS25
Ø5.0
DPI50
Initial Drill Ø2.2
TSD22F
Ø6.0
DPI60
Twist Drill Ø2.9
TSD29F
Twist Drill Ø3.4
TSD34F
Twist Drill Ø3.9
TSD39F
Twist Drill Ø4.4
TSD44F
Stopper
Connector Type
Code
Ratchet (Long)
RC15
Ratchet (Short)
RC10
IS Fixture Driver Length
Code
Type
Code
3.0 mm
DS030F
Ratchet (Short)
ISFDR10F
4.0 mm
DS040F
Ratchet (Long)
ISFDR15F
5.0 mm
DS050F
Contra Angle
ISFDH25SF
6.0 mm
DS060F
7.0 mm
DS070F
8.5 mm
DS085F
10.0 mm
DS100F
11.5 mm
DS115F
13.0 mm
DS130F
Code
PP10F
Code
HD1215
Code
DE01
Code
TW01
Code
MG00
Counter sink
Parallel Pin
Hex Driver Diameter
Code
Ø3.5
ISCS35F
Ø4.0
ISCS40F
Ø4.5
ISCS45F
Ø5.0
ISCS50F
Profile Tap
Drill Extension
Torque Ratchet Diameter
Code
Ø3.5
PTAP35F
Ø4.0
PTAP40F
Ø4.5
PTAP45F
Ø5.0
PTAP50F
Depth Gauge
13
IS Full Kit Components Surgical Drill
13 11.5 10 8.5 7
0 1.0
Point Lindemann Ø2.5
Initial Drill Ø2.2
Twist Drill Ø2.9
Twist Drill Ø3.4
Twist Drill Ø3.9
Twist Drill Ø4.4
>> * Function of Point Lindemann Drill ① Point Drill - Marking position of drilling(4~5mm Drilling) ② Side Cutting – Possible for Drilling in extraction hole and controlling path in drilling ※ All drills are designed 1.0mm longer than insertion length and Ø2.9 ~ Ø4.4 Twist Drills are desinged to prevent Over Drilling with Round Design on Drill Point(no need Stopper system, but recommended for D3~D4 bone)
Stopper
Stopper
3.0mm
4.0mm
5.0mm
6.0mm
7.0mm
8.5mm
10.0mm 11.5mm 13.0mm
Length(mm)
4.0mm
5.0mm
6.0mm
7.0mm
8.0mm
9.5mm
11.0mm 12.5mm 14.0mm
Length
※ Length means actual length in drilling. Drilling is deeper 1.0mm than stopper length when stopper connected. Stopper is connected with drill by following signal.
Countersink C (Super Hard Bone) B (Hard Bone)
※ Used for IS Fixture, considering Cortical Bone Density, possible to use for IS-II in some case.
A (Soft Bone)
>>
Ø3.5
Ø4.0
Ø4.5
Ø5.0
he depth controlling of countersink drilling is up to patient’s bone T density. In case that patient’s bone density is hard bone, depth is B line, bone density is soft bone, depth is A line. In case that bone density is super hard bone, C line is recommended.
Profile Tap Used for IS-II, IS-II active Fixture, effective for getting initial stability by tapping cortical bone. >>
>> easy tapping with four blades when using contra angle. 10mm Fixture 식립 시 8.5mm
14
7mm Ø3.5
Ø4.0
Ø4.5
Ø5.0
※ Tapping on cortical bone for upper part of Fixture. Drilling until Laser Marking Line on the upper part of Tap.<RPM 50, Torque 50>
IS-II active Drilling Sequence IS-II active Fixture Ø3.5 X 10mm (D1/D2 bone) Point Lindemann Ø2.5
Initial Drill Ø2.2
Twist Drill Ø2.9
* 1200 rpm / 30~45N.cm Profile Tap : 50rpm / 50 Torque
Profile Tap Ø3.5
D1 10mm
D2
Tip Length 1 mm
※ If bone is soft, only 10mm drilling with Ø 2.5 Lindemann drill
IS-II active Fixture Ø4.0 X 10mm (D1/D2 bone) Point Lindemann Ø2.5
Initial Drill Ø2.2
Twist Drill Ø2.9
Twist Drill Ø3.4
Profile Tap Ø4.0
D1 10mm
D2
Tip Length 1 mm
※ If bone is soft, only 10mm drilling with Ø2.9 Twist drill
IS-II active Fixture Ø4.5 X 10mm (D1/D2 bone) Point Lindemann Ø2.5
Initial Drill Ø2.2
Twist Drill Ø2.9
Twist Drill Ø3.4
Twist Drill Ø3.9
Profile Tap Ø4.5
D1 10mm
D2
Tip Length 1 mm
※ If bone is soft, only 10mm drilling with Ø3.4 Twist drill
IS-II active Fixture Ø5.0 X 10mm (D1/D2 bone) Point Lindemann Ø2.5
Initial Drill Ø2.2
Twist Drill Ø2.9
Twist Drill Ø3.4
Twist Drill Ø3.9
Twist Drill Ø4.4
Profile Tap Ø5.0
D1 10mm Tip Length 1 mm
D2
※ If bone is soft, only 10mm drilling with Ø3.9 Twist drill
15
2012.09.20 Ver.1