IS-II active Product Catalog
Contents S.L.A. Surface of IS-II active
4
Features of IS-II active
6
IS-II active Line up
8
Prosthetic Flow Chart
10
IS Full Kit
12
IS Full Kit Components
13
IS-II active Drilling Sequence
15
S.L.A. Surface of IS-II active S.L.A. (Sandblasting with Large grit and Acid etching)
IS-II active Surface
Macropore & Micropore
Macropores and micropores formed by S.L.A. surface treatment increase B.I.C.(Bone-Implant Contact) and allow better blood flow on the implant surface.
S.L.A. Surface
S.L.A.
S.L.A. surface is formed by undergoing the process of sandblasting with smaller than 50 ㎛ HA (Hydroxy Apatite) particles to roughen the machined surface and to form many macropores. After sandblastingand acid etching is done to increase B.I.C. and promote cell’s activity. With this process, the typical treatment period can be shortened and the patients will be more satisfied with the result.
S.L.A. Surface Treatment Process Miling
Sand Blasting
Acid Etching HA Powder
Machined
4
R.B.M.
S.L.A.
S.L.A. Surface of IS-II active Roughness of IS-II active Regular roughness / R.A. 2.0 (Roughness Average)
1,960 RA(㎛)
2,0 20 RA(㎛)
Other company’s S.L.A. Surface
Neobiotech’s S.L.A. Surface
Cell adhesion capability of S.L.A. Surface It is observed that S.L.A. surface has the capability of attaching more cells on the titanium surface than the machined or R.B.M. surfaces.
Machined
R.B.M.
S.L.A.
Measured distance of newly formed bone Measured distance of newly formed bone is approved to be longer in S.L.A. surface compared to R.B.M. surface.
R.B.M.
Distance of newly formed bone Left : 1.976mm/ Right : 2.35mm
F : Fixture / BM : Bone Marrow / NB : New Bone
S.L.A.
Distance of newly formed bone Left : 2.460 mm Right : 2.41mm
F : Fixture / BM : Bone Marrow / NB : New Bone
5
Features of IS-II active Based on the accumulated clinical cases and studies over 10 years, IS-II active has been continuously developed for the improvement. IS-II active has an internal submerged type design with S.L.A. surface that allows faster and stronger osseointegration.
BioSeal(0.5mm) BioSeal is a curved S shape placed at the top of the fixture broadens the surface and increases the attachment of the soft tissue, therefore minimizes the bone loss.
Straight–Taper Body helps implant to be drilled and inserted smoothly and also self-compaction is easily achieved in the soft bone.
Coronal Macro Thread
(Thread pitch 0 .8mm)
Coronal Macro thread gains better primary stability at the cortical bone that helps to achieve better fixation in immediate placement.
Magic Thread Magic Thread helps to achieve strong and stable initial fixation and also the inverted triangular threads enables to endure vertical and lateral forces.
Apex Apex is powerful in drilling and due to this selfcompactable and tapered apex design, initial fixation is easily achieved. It works great in both immediate placement and immediate loading.
S.L.A. Surface S.L.A. Surface has no impurities on the implant surface (No residual acid or cell toxicity is observed in the material examination). Also it has an appropriate rough average that can have the excellent osteoconductivity.
BioSeal BioSeal has a curved S shape with the application of 0 .5mm micro grooves on the machined surface. This design is invented to minimize the bone loss by maximizing soft tissue sealing.
Coronal Macro Thread Coronal macro threads helps to achieve excellent primary stability at the cortical bone and initial fixation at the apex is excellent, therefore IS-II active works great in both immediate placement and immediate loading.
Magic Thread Magic Thread with the inverted triangular shaped powerful deep thread helps to achieve strong and stable initial fixation and also this special design allows to endure vertical and lateral forces effectively.
6
Features of IS-II active Connection of IS-II active Conical Sealing & Internal Hex Structure 22
22 0 .4mm
- Group A : IS-II active all Narrow, Regular, Wide 7.3mm Fixture - Group B : IS-II active Regular, Wide 8.5, 10 .0 , 11.5, 13.0 mm Fixture
Group A (Gray)
Group B (White)
IS-II active Fixture is compatible with all abutments of IS system. * In order to increase the strength of fixture body, Internal hex of Group A is designed 0 .4mm higher than Group B.
Fixture Placement Procedure
Take the fixture out from the box
Remove the package surrounding the fixture
Connect the fixture to the driver
Take the fixture out from the holder
Take of the back seal
Take out the holder carefully
7
IS-II active Fixture Line Up Narrow Ø 3.5 Ø 3.5
Actual Size
Length
Length (mm)
Product Code
8.5
BIS350 8A
10 .0
BIS3510 A
11.5
BIS3511A
13.0
BIS3513A
Length (mm)
Product Code
7.3
BIS40 0 7A
8.5
BIS40 0 8A
10 .0
BIS40 10 A
11.5
BIS40 11A
13.0
BIS40 13A
Length (mm)
Product Code
7.3
BIS450 7A
8.5
BIS450 8A
10 .0
BIS4510 A
11.5
BIS4511A
13.0
BIS4513A
Length (mm)
Product Code
7.3
BIS50 0 7A
8.5
BIS50 0 8A
10 .0
BIS50 10 A
11.5
BIS50 11A
13.0
BIS50 13A
Ø 3.5
Regular Ø 4.0 Ø 3.7
Actual Size
Length
Ø 4.0
Regular Ø 4.5 Ø 3.9
Actual Size
Length
Ø 4.5
Wide Ø 5.0 Ø 4.4
Actual Size
Length
Ø 5.0
8
IS-II active Fixture Line Up S-wide Platform
Diameter (Ø)
Length
5.5
Platform (Ø)
4.4
Diameter
6.0
7.0
4.9
5.8
Length (mm)
Code
7.3
BIS550 7A
8.5
BIS550 8A
10 .0
BIS5510 A
11.5
BIS5511A
13.0
BIS5513A
7.3
BIS60 0 7A*
8.5
BIS60 0 8A*
10 .0
BIS60 10 A*
11.5
BIS60 11A*
13.0
BIS60 13A*
7.3
BIS70 0 7A*
8.5
BIS70 0 8A*
10 .0
BIS70 10 A*
11.5
BIS70 11A*
13.0
BIS70 13A*
Length (mm)
Product Code
5.0
BIS50 0 5A
6.0
BIS50 0 6A
5.0
BIS550 5A*
6.0
BIS550 6A*
Short Platform
Length
7.3mm
Diameter (Ø)
Platform (Ø)
5.0
4.4
5.5
4.5
Diameter
S-wide Kit
* S-Wide Kit is necessary to place S-wide Fixture and Ø 5.5 Short Fixture
9
Prosthetic Flow Chart Solid Abutment
Plastic coping
Lab analog
Impression cap
1.2 Hex driver
Healing abutment
Solid abutment
Protective cap
Cover screw
1.2 Hex driver
IS-II active
10
Prosthetic Flow Chart Cement & Screw Abutment
Straight
SCRP multi
Hex
R
Gold
SCRP multi
Hex
Non-hex Abutment positioner
Angled
R
Non-hex
CCM
Plastic coping
Hex
Non-hex
SCRP multi
Hex
Shapable
R
Non-hex
Plastic
Lab analog Hex
SCRP multi
R
Impression cap
SCRP multi
Pick up 1.2 Hex driver
Non-hex
Transfer
Abutment positioner
Healing abutment
Non-hex
Lab analog
R
Hex
Hex
Non-hex
Cover screw
Impression coping positioner
1.2 Hex driver
IS-II active
11
IS-II active Drilling Sequence IS-II active Fixture Ø3.5 X 10 mm (D1/D2 bone) Point Lindemann Ø2.3
Initial Drill Ø2.2
Twist Drill Ø2.9
Profile Tap Ø3.5
* Drilling Speed & Torque Point Lindemann, Initial Drill, Twist Drill : 1,20 0 R.P.M / 30 ~ 45 Ncm Profile Tap : 50 R.P.M / 50 Ncm
D1 10 mm
D2
Tip Length 1 mm
※ If the bone density is low and soft, drilling 10 mm with Ø 2.3 Lindemann drill and then place the fixture.
IS-II active Fixture Ø4.0 X 10 mm (D1/D2 bone) Point Lindemann Ø2.3
Initial Drill Ø2.2
Twist Drill Ø2.9
Twist Drill Ø3.4
Profile Tap Ø4.0
D1 10 mm
D2
Tip Length 1 mm
※ If the bone density is low and soft, drill 10 mm up to Ø 2.9 Twist drill and then place the fixture.
IS-II active Fixture Ø4.5 X 10 mm (D1/D2 bone) Point Lindemann Ø2.3
Initial Drill Ø2.2
Twist Drill Ø2.9
Twist Drill Ø3.4
Twist Drill Ø3.9
Profile Tap Ø4.5
D1 10 mm
D2
Tip Length 1 mm
※ If the bone density is low and soft, drill 10 mm up to Ø 3.4 Twist drill and then place the fixture.
IS-II active Fixture Ø5.0 X 10 mm (D1/D2 bone) Point Lindemann Ø2.3
Initial Drill Ø2.2
Twist Drill Ø2.9
Twist Drill Ø3.4
Twist Drill Ø3.9
Twist Drill Ø4.4
Profile Tap Ø5.0
D1 10 mm
D2
Tip Length 1 mm
※ If the bone density is low and soft, drill 10 mm up to Ø 3.9 Twist drill and then place the fixture.
IS-II active Fixture Ø5.5 X 10 mm (D1/D2 bone) Point Lindemann Ø2.3
Initial Drill Ø2.2
Twist Drill Ø2.9
Twist Drill Ø3.4
Twist Drill Ø3.9
Twist Drill Twist Drill Ø4.4 Ø4.9
Profile Tap Ø5.5
D1 10 mm Tip Length 1 mm
D2
※ If the bone density is low and soft, drill 10 mm up to Ø 4.4 Twist drill and then place the fixture.
15
STOP DRILL KIT
Linderman Drill Diameter
Product Name
⌀2.3
LDS23C
Stop Drill Diameter ⌀
Length
(mm)
⌀2.2
⌀3.0
⌀3.5
⌀4.0
⌀4.5
⌀5.0
7.3
TSD2207S9
TSD3007S9
TSD3507S9
TSD4007S9
TSD4507S9
TSD5007S9
8.5
TSD2208S9
TSD3008S9
TSD3508S9
TSD4008S9
TSD4508S9
TSD5008S9
10.0
TSD2210S9
TSD3010S9
TSD3510S9
TSD4010S9
TSD4510S9
TSD5010S9
11.5
TSD2211S9
TSD3011S9
TSD3511S9
TSD4011S9
TSD4511S9
TSD5011S9
13.0
TSD2213S7
TSD3013S7
TSD3513S7
TSD4013S7
TSD4513S7
TSD5013S7
7.3mm
8.5mm
10.0mm
11.5mm
13.0mm
STOP DRILL KIT Cortical Drill & Tap (0.8 , 0.9 Pitch) Cortical Drill
Diameter ⌀
Cortical Tap (IS II active)
Cortical Tap (IS III active)
FØ3.5
CD38
CT38S08
CT38S09
FØ4.0
CD43
CT43S08
CT43S09
FØ4.5
CD45
CT45S08
CT45S09
FØ5.0
CD50
CT50S08
CT50S09
FØ5.5
CD55
CT55S08
CT55S09
Fixture Driver
Connector
Length
Product Name
Length
Product Name
Ratchet(Short)
ISFD10R
Long
RC15
Ratchet(Long)
ISFD15R
Contra Angle(Short)
ISFD05C
Product Name
CAA00
Contra Angle(Long)
ISFD05CL
Direction Pin
Parallel Pin
Diameter
Product Name
Length
Product Name
⌀3.5
DPIS35C
7.0mm
PP07F
⌀4.5
DPIS45C
8.5mm
PP08F
10.0mm
PP10F
Drill Extension
Hex Driver Length(mm)
Product Name
15mm
HD1215S
Torque Ratchet Product Name
Product Name
DE01
Driver Holder & Depth Gauge TW60
Product Name
DHDG
IS CORE KIT IS Fixture Driver
Point Drill
Surgical Drill
Cortical Tap
Hex Driver
Ratchet
Connector
Torque Ratchet
Drill Stopper
Drill Extension
Product Name
Parallel Pin
NEOCKIT
Point Drill
⌀ 2.3
Drilling Sequence (IS-III active)
Surgical Drill Surgical Drill Surgical Drill Cortical Tap
⌀ 2.2 ⌀ 3.0 ⌀ 4.0 ⌀ 4.0
D1 D2
10mm Drill Tip 1.2mm
Drill Tip
1.2mm
bone or in condition of getting fixation at implant apex, Ø3.0 surgical drill is the final drill *※ InInSoft(D4) Soft(D4) bone or in condition of getting fixation at implant apex, ⌀3.0 surgical drill is
Point Drill
⌀ 2.3
Surgical Drill Surgical Drill Surgical Drill
⌀ 2.2 ⌀ 3.0 ⌀ 4.0
Option
Drilling Sequence (IS-II active) Drill Tip
1.2mm
* In Soft(D4) bone or in condition of getting fixation at implant apex, ⌀3.0 surgical drill is
IS CORE KIT Guide Point Drill
Surgical Drill
Diameter
Product Name
Diameter
Product Name
⌀2.3
PD13
⌀2.2
TSD22CL
⌀3.0 (3.5F)
TSD30CL
⌀3.5 (4.0F)
TSD35CL
⌀4.0 (4.5F)
TSD40CL
⌀4.5 (5.0F)
TSD45CL
Cortical Tap
Drill Stopper
Diameter
Product Name
⌀3.5
CTS38S09
⌀4.0
CTS43S09
⌀4.5
CTS45S09
Length(mm)
⌀5.0
CTS50S09
Product Name
IS Fixture Driver Product Name
ISFD05C
DE01
Length(mm)
Product Name
8.5
PP08F
10.0
PP10F
Product Name
RC15
Torque Ratchet HD1215S
Product Name
10.0
11.5
13.0
DS070C DS085C DS100C DS115C DS130C
Ratchet Connector
Hex Driver Product Name
8.5
Parallel Pin
Drill Extension Product Name
7.3
TW60
20 12.0 9.20 Ver.1
Neobiotech Co., Ltd. E-Space #10 10 , 212-26, Guro-dong, Guro-gu, Seoul, Koea 152-789 Tel : +82-2-582-2885 Fax : +82-2- 864-2894 Email : info@neobiotech.co.kr