Product Review

Page 1

2017. 05 Ver.1

2017 C A T A L O G

PRODUCTS R

E

V

I

E

W


IMPLANT SYSTEM IS-III active IS-II active IT-II active EB-II active S-mini Surgical Kit Neo Surgical Accessory Kit Neo Prosthetic Kit Neo Universal Prosthetic Kit Neo PickCap Impression Kit Neo Prosthetic Planning Kit Ridge Wider Kit

05 06 08 10 12 13 16 17 18 19 20 21

Sinus Lift / Repair Solution Neo SinusAll Kit SCA Kit SLA Kit FR Kit SR Kit-II

23 24 25 26 27

GBR Solution CTi-mem 2D CTi-mem ACM GBR Kit EZ GBR Kit

29 30 31 32 33

Digital Solution Neo NaviGuide System Neo NaviGuide Kit Block Encoded Healing abutment Scan body Ti Cylinder Abutment

35 36 37 38 39 40

Peri-implantitis Solution R-Brush i-Brush Dr. Plant

42 43 44

Other Dental Products Kerator Delikit Regenoss Calpore DM Bone Intergraft Traus / Neo Surge

46 46 47 47 48 48 49



04 I

Implant System

IS-III active IS-II active IT-II active EB-II active S-mini Surgical Kit Neo Surgical Accessory Kit Neo Prosthetic Kit Neo Universal Prosthetic Kit Neo PickCap Impression Kit Neo Prosthetic Planning Kit Ridge Wider Kit


IS-III active I 05

IS-III active 0.9 Pitch Increase contact area between thread pitch to enhance stability and osseointegration

Micro Groove Minimize boneloss and maintain bone level by treating superior area of fixture

S.L.A. Surface Improvement of S.L.A surface

Magic Thread Specially designed to endure vertical and lateral force

Wide Cutting Edge Improve fixation and increase clinician’s comfort during implant placement

Apex Excellent to both immediate placement and immediate loading

Length

Diameter

IS-III active Diameter (Ø) 3.5 4.0 / 4.5 / 5.0

IS-III active S-wide Length (mm) 8.5 / 10.0 / 11.5 / 13.0 7.3 / 8.5 / 10.0 / 11.5 / 13.0

Diameter (Ø) 5.5 / 6.0

Length (mm) 7.3 / 8.5 / 10.0 / 11.5 / 13.0

0.9


06 I IMPLANT SYSTEM

IS-II active BioSeal(0.5mm) Increase sealing of soft tissue and minimize bone loss Coronal Macro Thread (Thread pitch 0.8mm) Excellent primary stability at cortical bone S.L.A. Surface Under 50㎛ Hydroxy Apatite powder blasting and dual acid etching

Magic Thread Specially designed to endure vertical and lateral force

Apex Excellent to both immediate placement and immediate loading

IS-II active

∙ Internal Conical Connection ∙ 2.5 Hex ∙ Conical Seal(11°) Platform Switching Supports soft tissue interface for natural looking esthetics

Two conical contact point Creating a strong and stable fit between fixture and abutment

Diameter (Ø) 3.5 4.0 / 4.5 / 5.0

Length

Length (mm) 8.5 / 10.0 / 11.5 / 13.0 7.3 / 8.5 / 10.0 / 11.5 / 13.0

IS-II active S-wide Diameter

Diameter (Ø) 5.5 / 6.0 / 7.0

Length (mm) 7.3 / 8.5 / 10.0 / 11.5 / 13.0


IS-II active I 07

IS System Fixture

Healing & Cover Screw

Abutment

Impression Coping

Lab Analog

Excellent Solid Solid Pick Cap Straight Impression Cap Abutment Hex SCRPⓇmulti Non-Hex Positioner

Pick up Fixture Level

Angled

Healing Abutment

Cement

IS-III active

Hex

Shapable

Hex Gold Cover Screw

SCRPⓇmulti Non-Hex CCM

Plastic

Non-Hex Transfer Abutment Level

UCLA

IS-II active

SCRPⓇ multi

Hex

Non-Hex

Hex SCRPⓇ Non multi -Hex Temporary

Hex

Hex SCRPⓇ Non multi -Hex

SCRPⓇmulti

Hex Non -Hex

Non-Hex

Hex

Non-Hex

Impression coping positioner

Ball

Clinical

Lab

Retainer

Retainer

Housing

Housing

Ball Lab Analog


08 I IMPLANT SYSTEM

IT-II active G.Collar 1.8mm

IT-II active

Length

S.L.A. Surface Under 50㎛ Hydroxy Apatite powder blasting and dual acid etching

Apex Excellent to both immediate placement and immediate loading

Clinical Case

Diameter Diameter (Ø) 3.5 4.0 / 4.5 / 5.0 / 5.5

Magic Thread Specially designed to endure vertical and lateral force

Length (mm) 10.0 / 11.5 / 13.0 8.5 / 10.0 / 11.5 / 13.0

I Osteoconductivity Implant Surface (S.L.A.) I Crestal MacroThread Design I Self-Compactable Apex I Powerful Deep Thread I Conical Seal 8° I 3,1 Octa


IT-II active I 09

IT System Fixture

Healing & Cover Screw

Abutment

Impression Coping

Lab Analog

Impression Cap

Lab Analog

Solid

Excellent Solid Solid

Positioning Cylinder Shoulder Analog Wide Neck Solid Impression Positioning Cap Cylinder

Healing Abutment Cement

Straight

Wide NeckLab Analog

Angled Pick Cap Pick up

IT-II active

Octa Non-Octa

Cover Screw

Gold

CCM

Plastic

Transfer

Lab Analog

UCLA

Octa Non-Octa Wide Neck CCM

Wide Neck Lab Analog

Wide Neck Plastic Wide Neck Wide Neck Octa Non-Octa Transfer Impression Coping Positioner


10 I IMPLANT SYSTEM

EB-II active EB-II active BioSeal(0.5mm) Increase sealing of soft tissue and minimize bone loss

Length

S.L.A. Surface Under 50㎛ Hydroxy Apatite powder blasting and dual acid etching

Diameter Diameter (Ă˜) 3.5 4.0 / 4.5 / 5.0(i) 5.0(B)

Hex 2.4 2.7 3.4

Length (mm) 10.0 / 11.5 / 13.0 7.3 / 8.5 / 10.0 / 11.5 / 13.0 7.3 / 8.5 / 10.0 / 11.5 / 13.0

i : 3i type B : Brenemark type Magic Thread Specially designed to endure vertical and lateral force Apex Excellent to both immediate placement and immediate loading

Clinical Case

I Osteoconductivity Implant Surface (S.L.A.) I Crestal MacroThread Design I Self-Compactable Apex I Powerful Deep Thread I External Hex I BioSeal


EB-II active I 11

EB System Fixture

Healing & Cover Screw

Abutment

Impression Coping

Lab Analog

Straight

Cement

Hex

SCRPⓇ Non-Hex multi

Abutment positioner

Pick Cap Pick up

Angled

Hex

Single Gold

SCRPⓇ multi Hex

Healing Abutment

SCRPⓇ multi Non-Hex CCM

UCLA

EB-II active

Non-Hex Hex

SCRPⓇ multi Non-Hex

Fixture Level

Transfer

Plastic Hex Hex

Cover Screw

SCRPⓇ multi Non-Hex

Non-Hex Temporary

Hex

SCRPⓇ multi Non-Hex

Impression coping positioner

Ball

Clinical

Clinical

Retainer

Retainer

Housing

Housing

Ball Lab Analog


12 I IMPLANT SYSTEM

S-mini Cement Type

I RBM Surface I One body & Straight Tapper Structure

Diameter (Ø) 2.0 / 2.5 / 3.0 / 3.5

Ball Type

I RBM Surface I For Over Denture

Diameter (Ø) 2.0 / 2.5 / 3.0 / 3.5

Clinical Case

Length (mm) 8.5 / 10.0 / 11.5 / 13.0 / 15.0

Cuff 3.0 / 4.0

Length (mm) 8.5 / 10.0 / 11.5 / 13.0 / 15.0


S-mini Surgical Kit I 13

Surgical Kit IS Full Kit

Increase of clinician’s comfort by improving cutting force of surgical drills with dual length.

Clinicians are able to decide loading time by using of cortical drill or profile tap once patient’s bone density and other oral conditions are identified. Cortical Drill

Cortical Tap

Suitable for “delayed loading” by drilling of cortical bone

Suitable for “immediate loading” by tapping cortical bone

Delayed Loading

Immediate Loading (AnyTime Loading)

Improved cutting edge of drill point

Dual drill length


14 I MPLANT SYSTEM

Surgical Kit Neo Surgical Kit

Cortical Tap IS Full Kit ver.6 (for IS-II active)

Neo Surgical Kit ver.0 (for IS-III active)

8.9mm

8.9mm

0.5mm

5mm 0.8 pitch

5mm Ø3.5 Ø4.0

Ø4.5

Ø5.0

0.9 pitch

Ø3.5 Ø4.0

Ø4.5

Ø5.0

Due to the thread pitch difference between IS-II active and IS-III active, the Neo Surgical Kit has a new 0.9 pitch cortical tap.


Surgical Kit I 15

EB & IT Kit

S-mini kit

S-wide Kit


16 I IMPLANT SYSTEM

Neo Surgical Accessory Kit A kit composed of various tools to assist implant surgery or 2nd surgery.

Tissue Punch

Dia. Marker

Bone Planer

Bone Profile

QuickTight


Neo Surgical Accessory Kit Neo Prosthetic Kit I 17

Neo Prosthetic Kit A kit composed of Prosthetic Tool to aid prosthetic connection with ease and swiftness.

1.2 Hex Driver

1.25 Hex Driver

Abutment Positioner

Used to take exact position of hex and direction of abutment with one hand.

Angled Driver

Rounded hex design 25Âş

Hex 1.2

Access angle max 25° Tightening Torque max 30 Ncm

Hex 1.25 38Ncm

Handle neck is designed to be broke in 38 Ncm for prevent hex tip fracture


18 I IMPLANT SYSTEM

Neo Universal Prosthetic Kit Neo Universal Prosthetic Kit is composed of various prosthetic drivers compatible to different brands and sizes of implant abutments. This is a complete set of components for tightening and untightening clinical and prosthetic screws with an accurate torque value.

Name

Picture

Compatible implant or company

Code

Length(L)

1.2 Hex Driver (0.48�)

Neobiotech Biomet 3i Dentsply-Friadent, Xive, Osstem, DIO, Megagen

HD1210S

10mm

HD1215S

15mm

1.25 Hex Driver (0.5�)

Biohorizons Zimmer, Astra Implant Direct Legacy Camlog, MIS, Dentis, Dentium

HD12510S

10mm

HD12515S

15mm

SCS Driver

Straumann Implant Direct Replant

WSCSD10S

10mm

WSCSD15S

15mm

Unigrip Driver

Nobel Biocare Implant Direct Swishplait Southern Implants Neoss

WUGD10S

10mm

WUGD15S

15mm


Neo Universal Prosthetic Kit Neo PickCap Impression Kit I 19

Neo PickCap Impression Kit

Neo PickCap Impression Kit is composed of various sizes of impression copings and the pick-up typed ‘cap’ that connects on top of each copings. The short height of the impression copings enable closed tray impression and even bite registration.

Components Diameter

Length

Cap

Ø 3.5 3 mm 5 mm 8 mm 10 mm

Ø 4.0 3 mm 5 mm 8 mm 10 mm

Small

How to use

Ø 4.5 3 mm 5 mm 8 mm 10 mm

Ø 5.2 2 mm 3 mm 4 mm 5 mm 6 mm Large

Ø 5.7 2 mm 3 mm 4 mm 5 mm 6 mm

Ø 6.5 2 mm 3 mm 4 mm 5 mm 6 mm

Ø 8.0 3 mm 4 mm

Ø 9.0 3 mm 4 mm


20 I IMPLANT SYSTEM

Neo Prosthetic Planning Kit

Neo Prosthetic Planning Kit helps clinicians select the right size abutment by offering various sizes (diameter, cuff, and length) of prostheses.

Ø 4.5

I Straight I Silicon connection

Ø 5.2 Cuff 1, 2, 3, 4

Ø 5.7

Ø 6.5

Silicon

A-Type

(Angle to the edge) I Angled I Ring connection B-Type (Angle to the flat wall) Ring

Ø 4.5 / 15º Ø 4.5 / 25º Ø 5.2 / 15º Ø 5.2 / 25º Ø 5.7 / 15º Cuff 2, 4

Ø 4.5 / 15º Ø 4.5 / 25º Ø 5.2 / 15º Ø 5.2 / 25º Ø 5.7 / 15º


Neo Prosthetic Planning Kit Ridge Wider Kit I 21

Ridge Wider Kit

Safe Disk Non-saw type Disk-type blade for maximum safety Improved cutting performance through diamond powder coating 1,200~2,000rpm / Recommended use : 50 times

The ultimate ridge splitting solution in narrow alveolar ridge. The Safe Disk and Bone Expander from the Ridge Wider Kit enable safe and effective horizontal expansion and simultaneous implant placement in narrow ridges.

Saw type Saw-type blade with greater cutting performance (for experienced users) 1,200~2,000rpm / Recommended use : 50 times Safe intra-oral surgery with Plastic Cover on Disk

How to use

Trimming bone

Initial drilling

Cutting across the narrow ridge

Cutting the buccal side

Initial expansion with bone chisel

Sequential bone expansion

Implant placement

Application of graft material


22 I

Sinus Lift / Repair Solution

Neo SinusAll Kit SCA Kit SLA Kit FR Kit SR Kit-II


Neo SinusAll Kit I 23

Neo SinusAll Kit Crestal Approach 1 2 3 4 5 6 7

S-reamer Stopper Depth gauge Rotary elevator Bone condenser Ossteotome handle Aqua tap & Aqua valve

Lateral Approach 1 2 3 4 5

LS-reamer C-guide & C-reamer Stopper Elevator Side Cutter

Implant Placement 1 Surgical drill 2 Fixture driver 3 Torque ratchet wrench

Crestal Approach

Lateral Approach

Implant Placement


24 I Sinus Lift / Repair Solution

SCA Kit

Sinus Crestal Approach kit The special blade structure of the S-reamer head is designed to crestally drill into the sinus inferior cortical bone without sinus membrane tearing. As a bone disk is created between the membrane and the reamer, the reamer does not touch the sinus membrane directly, which enables safer sinus elevation. Bone Disk

Clinical Case

S-Reamer

Bone Inserter

Bone Condenser

Bone Spreader

Bone Carrier


SCA Kit SLA Kit I 25 LS-Reamer

SLA Kit

C-Reamer

Sinus Lateral Approach kit LS-Reamer safely drills into the lateral wall of the sinus by forming a thin bone disk between the reamer and the sinus membrane. Bone Disk

LS-Reamer

C-Guide

Elevator

Clinical Case

C-Reamer


26 I Sinus Lift / Repair Solution

FR Kit

Fixture Remover kit FR kit is a tool to remove a failed osseointegrated implant with marginal bone loss, or a stopped implant with excessive torque during insertion. By allowing minimal trauma or bone damage, the FR kit allows a new implant with the same diameter to be placed immediately after removal.

Failed implant

Clockwise

Clinical Case

Counterclockwise

Clear

Fixture Remover

Screw Driver Fixture Remover Screw

Torque Wrench


FR Kit SR Kit-II I 27

SR Kit

Reverse

Screw Remover kit SR kit is composed of multiple tools to quickly and safely remove a fractured screw.

Claw Drill Reverse

Fractured screw

Perfect Guide

Reverse Drilling

Screw Removing Reverse Screw Drill Remover

Clinical Case


28 I

GBR Solution

CTi-mem 2D CTi-mem ACM GBR Kit EZ GBR Kit


CTi-mem I 29

CTi-mem Cover Screw New CTi-mem Universal Spacer

Fixing Screw

Easy to customize Cover Screw

Easy to remove without a second surgery

New CTi-mem

Perfectly maintain bone volume

Tent Screw

Fixing Screw makes proximal and lateral fixations both vertically and horizontally even in large defect Perfectly compatible with the New IS Spacer and Tent Screw

Fixing Screw

Clinical Case


30 I GBR Solution

2D CTi-mem Customized titanium membrane Easy use with bending and minimal cutting Sufficient blood supply through enlarged pore size (Ø 1.25) Two line-ups to work with both the new EZ-Fixing screw and the original Tent screw and Spacer

Tent Screw Type Ø 1.25 Ø 2.5

EZ-Fixing Screw Type Ø 1.25

Ø 0.7 Ø 0.4 Ø 1.25

Clinical Case


2D CTi-mem ACM I 31

ACM

Length (mm)

AutoBone Chip Maker Collect high quality autogenous bone for good bone formation Diameter(Ă˜) Stopper stops within 4mm of depth and receive more amount of bone chips by compression.

Collect 1cc bone chip within 10 seconds Bone chip form makes easy to handle for bone grafting Adjustable bone volume according to different diameters Prevent slip with the pointer Excellent cutting force Prevent bone heating through sufficient irrigation Diameter (Ă˜) 4.0 / 4.5 / 5.0 / 6.0

Clinical Case

Length (mm) 10.0 / 15.0


32 I GBR Solution

GBR Kit

With Tent Screw, primary vertical and horizontal formation is possible without placing the implant By utilizing the Cover Screw, the CTi-mem is easily fixed onto both the implant (spacer) and Tent Screw Secondary stabilization of the membrane is completed with Fixing Screw Bone formation utilizing Spacer, Membrane and Cover Screw after placing Implant

Clinical Case


GBR Kit EZ GBR Kit I 33

EZ GBR Kit EZ Fixing System is designed to redeem the GBR procedure failure caused by misrecognition of the position of the residual bone and of the Cover Cap hole.

Membrane guide/ removing part Cover Cap joint Torque transmissing/ Fixing part

0.9mm Pitch Single Thread

Self Tapping Cutting Edge

Clinical Case


34 I

Digital Solution

Neo NaviGuide System Neo NaviGuide Kit Block Encoded Healing abutment Scan body Ti Cylinder Abutment


Neo NaviGuide System I 35

Neo NaviGuide System The integrated digital workflow of Neo NaviGuide system enables effective communication, provides new business opportunities, and increases treatment efficiency. CBCT Scans / Surface Scans

Implant Planning by the implantologist and technicians

Sending data

Neo NaviGuide Design

Implant Planning Confirmation by the Dentist

Neo NaviGuide Center

Dental Clinic

Delivery

Implant placement with the Neo NaviGuide

Clinical Case

Fabrication of the Neo NaviGuide

Abutment & Crown Design


36 I Digital Solution

Neo NaviGuide Kit Neo NaviGuide Kit R/W ver.0 Ø3.5 7.3mm 8.5mm 10mm 11.5mm 13mm

A

Ø4.0

Ø4.5

Ø5.0

✓ ✓ ✓ ✓ ✓

✓ ✓ ✓ ✓ ✓

✓ ✓ ✓ ✓ ✓

B

D

C

E

A

B

C

D

E

Tissue Punch Bone Trimmer Bone Profile

Handle free Stop Drills

Cortical Tap Countersink Drill

Vertical Anchor

Implant Tool

Neo NaviGuide Kit Narrow ver.0 Ø3.5 7.3mm 8.5mm 10mm 11.5mm 13mm

Ø4.0

Ø4.5

A

B

Ø5.0

✓ ✓ ✓ ✓

C

D

E

A

B

C

D

E

Point Drill Drill Extension

Handle free Stop Drills

Cortical Tap

Connector

Fixture Mount Fixture Driver


Neo NaviGuide Kit Block I 37

Block

0120

B Type

High flexural strength block

Indicated for posterior and long bridge frameworks S Type

Translucency block.(1,500℃)

Bending strength less than B type block ET Type

Super translucency block. (1,600℃)

Indicated for anterior and full crown and inlay/onlay

Zirconia Disk Block TOSOH(Japan) Zirconia Powder 100% Diameter 100mm Thickness 10, 12, 14, 16, 18, 20, 22, 25 mm


38 I Digital Solution

Encoded Healing abutment Able to take digital impression without removing Healing abutment

A B C D E

Connect the Scan pin onto the upper part of the Encoded Healing Abutment

Diameter

Combine the library data after scanning with the intra-oral scanner Height

A B

C D E

Clinical Case

Scan pin Connection of Healing Abutment when scanning

M2 Screw Fixation of IS Healing Abutment by connecting to Fixture.

Recognition of Hex direction

Function to recognize the hex direction while scanning a Healing Abutment

Recognition of gingival height

Function to recognize gingival height while scanning a Healing Abutment.

Hex to prevent rotation

Function to prevent rotation of prostheses


Encoded Healing abutment Scan body I 39

Scan body Able to take fixture level impression of an implant

B C A

D E

Clinical Case

Connect the Scan Body after removing the abutment Combine the Library data after scanning the oral scan body

A B C D E

Connection Height Decide Connection height when combining the fixture data

Oral Scan Body Screw Fix the Scan Body by connecting to fixture.

Cylinder of the Scan body Path coordination when combining the fixture data

Cross section of the Scan Body

Hex direction recognition when combining the fixture data

Fixture


40 I Digital Solution

Ti Cylinder Abutment I Ti Cylinder for Hybrid Custom Abutment I Diameter Ø4.5 / Ø5.5 I Hex / Non-Hex / SCRP

Hex

Non-Hex

SCRP

VS

Ti Links

Clinical Case

Anterior

Posterior

Ti Cylinder


I 41

Peri-implantitis Solution

R-Brush i-Brush Dr. Plant


42 I Peri-implantitis Solution

R-Brush Implant Round Brush Perfectly cleans the infected implant surface Titanium Alloy Bristles Diameter Ă˜5.6 / Ă˜6.6 2,000~5,000 rpm with solution (1:1) Single use

Clinical Case


R-Brush i-Brush I 43

i-Brush Easy to use ( Flapless) Perfectly cleanse the infected surface of the implant Reproduce rough surface by cleansing with i-Brush Prevent persistent bone loss Facilitate new bone regeneration Decrease failure rate

Before

Clinical Case

i-Brush 1

After

i-Brush 2


44 I Peri-implantitis Solution

Dr. Plant

Electronic brush for peri-implant mucosa Home care management and prevention of peri-implantitis Easy application and clear vision of one’s oral cavity through included mirror and LED lights 5 different size adjustable toothbrush for patients’ oral conditions S Tip

3S Tip

Battery type makes simple and economic maintenance GingiBrush for patients Functional toothpaste for gum treatment / Ingredients: Vitamin C · E, propolis, peppermint oil and others

How to use


I 45

Other Dental Products

Kerator Delikit Regenoss Calpore DM Bone Intergraft Traus / Neo Surge


46 I Other Dental Products

Kerator

Delikit

Overdenture attachment system

Impression material

Light body Light

Zero“0” Retention

Extra light angled

Strong

1.2 Ibs

Light angled

2.4 Ibs

Angled

4 Ibs

Plastic Carrier Allow easy and safe handling of the abutment inside the oral cavity Easy to check height and path

Excellent Durability With its nylon cap, 50,000 repeated use is available

Superior mobility Compensation of angle difference without loading even path is poor Patients easily remove

Heavy body

Delikit putty

Light body AAF(Air Adjustive Force) Technique Thixotropic texture : non-flowable High tear strength Excellent reproducibility for the margin area Working time : 1’30” / setting time : less than 4’ 50ml 1ea

Heavy Body Easy to apply Excellent elastic recovery / Easy to remove in oral cavity Strengthens after tray setting Compatible with all silicon impression materials Working time : 1’30” / setting time : less than 4’ 50ml 1ea

Putty

Dual-undercut design which is increased coherence with denture resin

Easy to mix Oil does not stick to hand Reduced chair time when taking two step impressions Working time : 1’/ setting time : less than 3’ base, catalyst 300ml each/box + 2 spoons included

Manufacturer : DAEKWANG IDM

Manufacturer: HappiDEN

The edge proof metal housing

AS Type :

0120

FDA

Approved

SQ Type :

0086

FDA

Approved


Kerator / Delikit Regenoss / Calpore I 47

Regenoss Allograft

Type

Particle

Syringe 0.2~1.0mm Vial

Size 0.3cc 0.6cc 1.0cc 0.3cc 0.6cc 1.0cc

Product Code CBP03 CBP06 CBP1 CBP03-V CBP06-V CBP1-V

Calpore Alloplastic

Type

Particle

Bowl

0.5~1.0mm

Size 0.25cc 0.5cc 1.0cc

Product Code PBBG00025 CPG1005 CPG101

Features

Features

Excellent biocompatibility

Optimal pore structure for faster bone reconstruction & regeneration

Excellent ossification by ideal mixture of bones ((Cortical bone (70%) + Cancellous bone (30%)) Provide a suitable space to grow new bone by the mixture of cancellous bone 70% of cortical bone: To enhance primary stability and to strengthen osteoinduction by growth factor Syringe packing for rehydration FDBA (Freeze Dried Bone Allograft) method Manufacturer: Cellumed

FDA

Approved

Outstanding and higher mechanical stabilization (21 Mpa) than the solidity of other alloplastic bone materials (2~10 Mpa) Circular pore allows optimal bone conduction rate by maximizing blood flow through minimizing surface tension β-TCP 60% + HA 40% Manufacturer: Kyungwon Medical


48 I Other Dental Products

DM Bone Alloplastic

Type

Particle 0.3~0.5mm

Vial 0.5~1.0mm

Size 0.25cc 0.5cc 1.0cc 0.25cc 0.5cc 1.0cc

Product Code MT1201 MT1203 MT1205 MT1202 MT1204 MT1206

Intergraft Xenograft

Type

Particle

Syringe 0.2~1.0mm Vial

Size 0.3cc 0.5cc 0.3cc 0.5cc

Product Code INTERGRAFT025 INTERGRAFT050 INTERGRAFT025-V INTERGRAFT050-V

Features

Features

Silicon-contained Hydroxy Apatite

Ideal combination between Cortical Bone and Cancellous Bone (8:2 ratio)

Optimal HA and B-TCP ratio (6:4 ratio) Silicon-Ion substitution technology to promote bone regeneration and healing

Outstanding osteoconduction and osteoinduction

Outstanding biocompatibility (No biological rejection and no risk of infection)

100% Australian Bovine

Excellent osteoblast activity by wide surface area Manufacturer: Cellumed

FDA

Approved

Stored at room temperature / lengthy expiration date Economical price Manufacturer: Cellumed


DM Bone / Intergraft Traus / Neo Surge I 49

Traus / Neo Surge Implant engine

Neo Surge Non-Optic

Features BLDC motor with high performance is adopted (Maximum torque up to 65Ncm is available through 32:1 contra angle) Power-on self-test notifies any errors or problems Real time torque value is displayed on the controller during insertion

Traus Optic

The motor is automatically stopped and an ‘Error’ sign is indicated on the LCD when the load is higher than the torque value This model is 100% compatible with the angles of other companies like NSK, NAVO, etc Manufacturer: Saeshin United (KOREA) 0120

Item Supply voltage Max. output power Motor speed Motor toque Gear ratio Coolant flow Width / Depth / Hight weight

Content AC 100~120V or 220-240V~, 50 / 60 Hz 120W 30~2,500rpm (20:1), 20~1562rpm (32:1) 5.0~55Ncm (20:1), 5.0~65Ncm (32:1) 1:5, 1:4, 1:1, 16:1, 20:1, 27:1, 32:1, 64:1 approx. 75 ml/min 205 x 210 x 316mm (non-optic), 233 x 269 x 120mm (optic) 3.3kg (non-optic), 4.5kg (optic)

Item

Product Code SS001OT Engine SS001 SS008 SS002 Handpiece SS005 SS009 SS004 Irrigation Tube SS006

Note Optic Non Optic 32:1, Optic 32:1, Non Optic 20:1, Non Optic 16:1, Non Optic Single-use Multi-use


PRODUCTS R

Neobiotech Co.,Ltd

10F, 36, Digitalro-27Gil, Guro-Gu, Seoul, Korea, 08381

Tel 82-2-582-2885, Fax 82-2-582-2883 www.neobiotech.com / Made in Korea

E

V

I

E

W


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.