Technikband GB_05
17.08.2006 9:50 Uhr
Seite 1
NBK Ceramic ARCHITECTUR AL TERR ACOT TA
NBK Ceramic GmbH & Co.KG Reeser Straße 235 D-46446 Emmerich Germany Phone +49 (0) 28 22 / 81 11-0 Fax +49 (0) 2822 / 81 11-20 E-mail: info@nbk.de
NBK (UK) Office John Wimbush PO Box 6779 · Ripley · Derbyshire, DE5 8YQ Phone +44 (0) 1773 512 363 Fax +44 (0) 1773 512 644 E-mail: john@nbk-uk.com
www.nbk.de
ARCHITECTURAL TERRACOTTA
GB
NBK Ceramic ARCHITECTUR AL TERR ACOT TA
Technikband GB_05
2
17.08.2006 9:51 Uhr
Seite 3
TERRART ®
ARCHITECTURAL TERRACOTTA
1
2
6
3
4
7
1 Potsdamer Platz, Berlin / D Architects: Renzo Piano Building Workshop 2 AIG European Headquarters, London / GB Architects: KPF London / New York
5
3 Landesbank Baden-Württemberg, Stuttgart / D Architects: WWA Architects Stuttgart / Munich 4 Sammon Keskuslukio / FIN Architects: Arkkit. TSTO OP Jokela Ltd., Helsinki 5 Center for Government and International Studies, Harvard University, Boston / USA Architects: Pei Cobb Freed & Partners, New York 6 Evelina Children’s Hospital, London / GB Architects: Hopkins Architects 7 City Square, Liverpool / GB Architects: GM Architects 8 Hilton Hotel, London / GB Archtects: Jestico + Whiles
8
3
Technikband GB_05
4
1
17.08.2006 9:51 Uhr
Seite 5
TERRART 速
ARCHITECTURAL TERRACOTTA
2
7
3
4
5
8
1 Temple House, Birmingham / GB Architects: GMW
6
2 Office Development, Farnborough / GB Architects: Allies and Morrison 3 Telford College, Edinburg / GB Architects: HOK 4 Bilborough College, Nottingham / GB Architects: CPMG 5 Oldham College, Oldham / GB Architect: Pringle Richards Sharrat 6 Bio-Medical, Glasgow / GB Architects: Boswell Mitchell Associates 7 Jamaica Street Car Park, Glasgow / GB Architects: Farrell & Clarke 8 Eastburne Terrace, London / GB Architects: Fletcher Priest
5
Technikband GB_05
6
17.08.2006 9:52 Uhr
Seite 7
TERRART 速
ARCHITECTURAL TERRACOTTA
3
1
4
5
2
7
6
1 Natural History Museum, London / GB. Architects: HOK Architects London 2 New Art Galery, Walsall / GB. Architect: Caruso St. John 3 Vodafone World Headquarter, Newbury / GB. Architect: Fletcher Priest London 4 Parliament View, London / GB. Architects: EPR Architects London 5 Royal Infirmary, Manchester / GB. Architects: Pulmann Associates 6 Riverside Houe, London / GB. Archtects: RHWL Architects London 7 Office building Davies Street, London / GB. Architechts: KPF Architects, London
7
Technikband GB_05
8
17.08.2006 9:53 Uhr
Seite 9
TERRART®-LARGE
TERRART®-MID
TERRART®-SOLID
TERRART®-SHINGLE
Large format ceramic elements
Medium-sized format ceramic elements
Solid ceramic elements
Ceramic shingle
Hollow chamber cross-section with a thickness of 40 mm.
Hollow chamber cross-section with a thickness of 30 mm.
Solid ceramic cross-section with a thickness of 30 mm for
Hollow chamber cross-section with a thickness of 40 mm.
Variable heights and lengths on request.
Variable heights and lengths on request.
use as a prefab facing element or as a mounted façade
Variable heights and lengths on request.
Height: max. 600 mm
Height: max. 300 mm
system. Calibrated on two sides or all sides.
Height: max. 600 mm
Length: max. 1,800 mm
Length: max. 1,200 mm
Length: max. 1,800 mm Height: max. 600 mm Length: max. 1,200 mm
Surface: smooth, polished, textured or peeled Mass per unit area: approx. 65 kg/m2
Special feature: also available as regular curved cross-
Special feature: also available as regular curved cross-
Variable heights and lengths
section R ≥ 6 m
section R ≥ 6 m
Mass per unit area: approx. 65 kg/m2
Surface: smooth, polished, textured or peeled, curved
Surface: smooth, polished, textured or peeled, curved
surfaces only: smooth, textured or peeled
surfaces only: smooth, textured or peeled
Mass per unit area: approx. 65 kg/m2
Mass per unit area: approx. 55 kg/m2
9
Technikband GB_05
10
17.08.2006 9:54 Uhr
Seite 11
TERRART®-BAGUETTE
Ceramic square pipes ®
TERRART®-PROFILES
A multitude of profiles are available for the surface design ®
TERRART®-VARIANTS
The range of TERRART® products offers numerous other
element if required. All bonded single elements must ad-
The TERRART -Baguette is one of the ceramic variants.
of the TERRART ceramic elements. The broad design
ceramic variants.
ditionally be fixed mechanically on the construction site
Its minimum cross-section is 40 x 40 mm. The cross-
spectrum ranges from the finest structure up to the strongly
On an individual basis, custom production is possible for a
(by the customer) in accordance with DIN 18516 part 3,
section of the most common format is 50 x 50 mm.
profiled plastic relief. Natural surfaces, horizontal profiles
particular property, through to elements with varying radii
point 3.2 (both sides in the case of corners, on three sides in the case of U-shaped elements).
and peeled surfaces are part of our standard program. In
for the creation of elliptic shapes. Production is carried out
Special feature: also available as regular curved cross-
addition, TERRART® façades can also be designed with
according to specifications, also as a hand-made single
section R ≥ 6 m.
individual profiles and surfaces.
Surface: smooth, ground, textured as double-baguette or peeled, curved surfaces: smooth only. Weight: approx. 5 kg per running metre for baguettes 50 x 50 mm, approx. 2.5 kg per running metre for baguettes 40 x 40 mm.
11
Technikband GB_05
12
17.08.2006 9:54 Uhr
Seite 13
TECHNICAL DATA SHEET FOR UNGLAZED NATURAL TERRA COTTA TILES
COLOURS AND SURFACES
natural surface
water absorption colour: 1.01-0 Arezzo white 2.01-0 Molino light yellow 5.01-0 Torrita terra cotta red 6.01-0 Siena red
EN ISO 10545 part 12
bending tensile strength colour: 1.01-0 Arezzo white 2.01-0 Molino light yellow 5.01-0 Torrita terra cotta red 6.01-0 Siena red
EN ISO 10545 part 4 (replaces EN 100)
4.5 - 6.0 % 4.0 - 5.7 % 4.3 - 6.3 % 4.3 - 6.4 %
13 - 20 N/mm2 17 - 24 N/mm2 15 - 25 N/mm2 14 - 20 N/mm2
1.01-0
1.01-1
2.01-0
2.01-1
3.01-0
3.01-1
4.01-0
4.01-1
5.01-0
5.01-1
6.01-0
6.01-1
6.02-0
6.02-1
7.03-0
7.03-1
7.04-0
7.04-1
8.01-0
8.01-1
9.04-0
9.04-1
glaze surface
2.09 - 2.16 kg/dm3
raw density linear thermal expansion ∆t = 100°C
honed surface
EN ISO 10545 part 8 (replaces EN 103)
< 0.4 mm referring to a length of 1,000 mm 36.5 - 66.5 N/mm2
compressive strength freeze / thaw resistance
EN ISO 10545 part 12 (100 cycles)
fulfilled
efflorescence and soluble salts
DIN 105 part 1
well below the permitted maximum limit
chemical resistance
DIN 105 part 4
fulfilled
width 400 mm to 1,450 mm
center in hole direction
+/- 1.0 mm for cuts
height 150 mm to 500 mm (colour M 6.01-0 and M 6.02-0 just to max. 450 mm)
opposite to hole direction
+/- 2.0 mm to 250 mm +/- 2.5 mm to 400 mm +/- 3.0 mm to 500 mm
thickness 30 mm or 40 mm
DIN EN ISO 10545-2 deviation if surface is honed
+/- 1.5 mm
straightness in hole direction
DIN EN ISO 10545-2
+/- 0.25 % of length
diagonal flatness
DIN EN ISO 10545-2
+/- 0.25 % of diagonal
vertical flatness cross to hole direction
DIN EN ISO 10545-2
+/- 1.0 % of height
torsion
DIN EN ISO 10545-2
+/- 0.25 % of diagonal
dimensions and tolerances
Remark: All other formats, dimensions and special sizes are available on inquiry basis. Subject change without notice. NBK, February 2006
TERRART® glazes and honed finishes are being
allows our company, in consultation with designers of
increasingly
in
exclusive product assortments, to make unique buildings.
contemporary architecture. NBK's expertise in compli-
The colors shown represent only a few of our overall
cated
range. Any required shade can be provided upon
exploited
mixing
as
a
techniques
design and
feature
traditional
firing methods, allows virtually any colour and surface texture specification to be met to the letter. This
request.
13
Technikband GB_05
14
17.08.2006 9:55 Uhr
Seite 15
TERRART®-FLEX-SYSTEM
THE RAINSCREEN SYSTEM
The NBK TERRART® ceramic clay tile façade system,
Driven rainwater will not enter the cavities because of
which is based on the rainscreen principle, is custom
the overlapping joints („protected openings“) and lack
designed and engineered.
of pressure differential.
The vertical joints are backed by a support system which
The „back ventilation“ assists in maintaining a dry cavity
drains rainwater away from the cavities behind. The
and negates the build up of hot air, an additional benefit
gaskets, together with balanced air pressure, discourages
to the TERRART® rainscreen system.
water from entering the wall cavities. The tile design allows for air to flow through „open joints“, which helps to balance air pressure in the cavities behind the terra cotta cladding elements with that of outside air, hence, the term – pressure equalization.
15
Seite 17
HORIZONTAL SECTION WINDOW SOFFIT
HORIZONTAL SECTION
Height displaced plug
Heat insulation
T1 vertical profile
Plugs suitable for the statics of the building
Joint profile Pin
TERRART速-Large Heat insulation
Tile holder
Module
T2 vertical profile
Tile holder
Spacer profile
Module TERRART速-Large
VERTICAL WINDOW SOFFIT
Module
Module
VERTICAL SECTION
Module
16
17.08.2006 9:55 Uhr
TERRART速-Large
Module
Technikband GB_05
Heat insulation
Heat insulation
17
18
17.08.2006 9:55 Uhr
Seite 19
TERRART 速 BAGUETTE SYSTEM
DETAIL EXTERNAL CORNER
Height displaced plug
Module
Technikband GB_05
Heat insulation T1 vertical profile Pin Joint profile
Module
Tile holder
Module
DETAIL INTERNAL CORNER
TERRART-Large Module
19
Technikband GB_05
20
17.08.2006 9:56 Uhr
Seite 21
TERRART 速-BAGUETTE
TERRART 速-BAGUETTE
21
Technikband GB_05
22
17.08.2006 9:56 Uhr
Seite 23
PACKING AND SHIPPING
CONVINCING FAÇADES
PROGRESS THROUGH DIVERSITY
23
For further information on trends, technical developments and current construction projects please visit our web site at:
For shipping and transport, NBK provides packing of all
The advantages of the TERRART® product series are
terra cotta elements in custom made heavy duty wooden
appreciated by an ever increasing number of architects.
crates or on pallets. All pieces are carefully packed;
The versatility and the almost limitless applicability of the
fibreboard and styrofoam are used as spacers so that the
terra cotta façade elements open up possibilities that
tiles cannot touch each other.
creative and innovative designers need to realize their ideas.
This packing will limit damage during shipping and transport under normal conditions.
www.nbk.de