Knauf Fire Rated Deflection Heads

Page 1


Knauf Fire Rated Deflection Heads

Revisions

Document Purpose and Scope

Knauf Performer ‘C’ Stud Partitions & Knauf ‘C’ Stud Partitions - Hybrid

Knauf Performer Partition with Resilient Bar

Knauf Isolator (Twin Frame) Partitions & Knauf Isolator (Twin Frame - Hybrid) Partitions

Knauf Shaftwall

Knauf Smokeshaft

Knauf ‘I’ Stud Linings (fire resistance performance systems)

Knauf AQUAPANEL® Indoor Board/Interior System

Amendment table

For further information on these amendments, please contact our Technical Services via email; technical-uk@ knauf.com or call 0800 521050 (option 2).

001 New publication launch: Knauf Fire Rated Deflection Heads (April 2024) 29.04.2024 MB

002

003

1. Additional wording added to sub-headers throughout document - ' or +/12.5mm'. 2. Image summary added throughout document on isometric images

1. Designation change of EI30, EI90, E120 to EI 30, EI 90, EI 120 - all systems (various pages). 2. Standard change from EN 1364-1 to BS EN 1364-1, all systems (various pages). 3. Knauf Performer EI 30 (Insulated Cavity), additional system added - 1 x 12.5mm Wallboard (page 10). 4. Title change and addition of isometric detail - Knauf Isolator (Twin Frame) & Knauf (Twin Frame - Hybrid) Partitions (page 22). 5. Updated Knauf Isolator details EI90 and EI120 (insulated), with generic constructions. 6. Updated Knauf ‘I’ Stud Lining detail with additional system incorporated, allowing now two options. 01.10.2024 MB

Testing Methodology: BS EN 1363-1 & BS 476-20

• Knauf interior drywall partition systems* that achieve a fire resistance performance are tested in accordance with BS EN 1363-1 and BS EN 1364-1. These are the most up to date and most rigorous test methodology standards to follow. Knauf therefore recognises the need for tested solutions to, as much as is practicable, reflect the as-built solutions required by customers. Therefore, Knauf has conducted a comprehensive fire resistance test program to provide a new set of fire rated deflection head details. All the Knauf systems in this document are supported by fire test evidence to BS EN 1364-1:2015.

• The arrangements within this document are only acceptable to the stated system fire resistance performance in conjunction with the Knauf Plasterboards listed beneath the details and the specific fire rated deflection head detail shown. All Knauf systems tested with deflection heads can be found on Knauf Planner Suite.

• The details within this document are not to scale. The details have been drawn in such a way as to highlight certain components and provide clear layouts and arrangements and do not constitute construction issue details.

• This document must be viewed in conjunction with Knauf EN and BS Compliance Systems and Knauf standard detail packs and Knauf fire resistance test data.

Knauf Approach & Recommendation

• Knauf advise and promote that EN compliance should be followed. That is to say Knauf advise utilising an BS EN 1364-1:2015 fire resistance test and extend the maximum height of a drywall partition system via either BS EN 15254-3 or BS EN 1364-1 or via a fire resistance test within a test rig greater than 3m in height.

• Projects that wish to use the BS 476 series must gain agreement between the Client, Accountable Persons, Duty Holders, and Local Building Control that the cold state height is an acceptable methodology for systems that go beyond its tested height.

For further information on use of these standards, please review the Compliance-documents.

*Performer (Partitions), Performer (Partitions with Resilient Bar), Isolator (Twin Frame), Shaftwall, Smokeshaft and Independent ‘I’ Stud Lining.

Knauf Performer Partitions

The Knauf Performer system is our most versatile and commonly used partition system. It is constructed using a single row of Knauf metal studs with Knauf plasterboards to both sides in order to meet fire, acoustic, moisture and impact requirements. The Performer system is lightweight, simple to construct and should be used in conjunction with Knauf’s finishing solutions range.

Isometric of Knauf Performer ‘C’ Stud Partition

Knauf Performer EI 30

Knauf Performer System Deflection Head Suitable for fire resistance of 30 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf Performer System Deflection Head suitable for fire resistance of 30 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm

Table 1

Table 1

EI 30 Knauf Performer Systems: Single Layer Plasterboard to both sides

1 × 12.5mm Knauf Fire Panel

1 × 12.5mm Knauf Performance Plus

1 × 12.5mm Knauf Soundshield Plus

1 × 15mm Knauf Wallboard

1 × 15mm Knauf Moisture Panel

1 × 15mm Knauf Fire Panel

1 × 15mm Knauf Soundshield Plus

1 × 15mm Knauf Performance Plus

EI30 Knauf Performer System: Single Layer Plasterboard to both sides

1×12.5mm Knauf Fire Panel

1×12.5mm Knauf Performance Plus

1×12.5mm Knauf Soundshield Plus

1×15mm Knauf Wallboard

1×15mm Knauf Moisture Panel

1×15mm Knauf Fire Panel

1×15mm Knauf Soundshield Plus

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Knauf Performer EI 30 – Single Layer (Insulated Cavity)

Knauf Performer System Deflection Head

Suitable for fire resistance of 30 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf Performer System Deflection Head suitable for fire resistance of 30 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of-25mm and 25mm Knauf Insulation Acoustic Roll

2×19mm Knauf Coreboard

Table 2

25mm Knauf Fixing, to suit specification

Approved Fixing, to meet suitability of substrate/loadings

EI30 Knauf Performer System: Single Layer Plasterboard to both sides

EI 30 Knauf Performer Systems: Single Layer Plasterboard to both sides

1 x 12.5mm Knauf Wallboard

1×12.5mm Knauf Fire Panel

1×12.5mm Knauf Performance Plus

1×12.5mm Knauf Soundshield Plus

1 × 15mm Knauf Wallboard (for applications with minimum Knauf 70mm ‘C’ (0.55) studs)

1×15mm Knauf Wallboard

1 × 15mm Knauf Moisture Panel (for applications with minimum Knauf 70mm ‘C’ (0.55) studs)

1×15mm Knauf Moisture Panel

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

1×15mm Knauf Fire Panel

1×15mm Knauf Soundshield Plus All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Knauf Performer EI 60 – Single Layer

Knauf Performer System Deflection Head

Suitable for fire resistance of 60 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf Performer System Deflection Head suitable for fire resistance of 60 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm

Approved Fixing, to meet suitability of substrate/loadings

Knauf Angle Section 25×50mm

Concrete Soffit

Knauf Insulation Rocksilk® RS60 2×19mm Knauf Coreboard

Deflection Allowance Deflection Allowance Deflection Allowance

Table 3

25mm Knauf Fixing, to suit specification

Knauf Intumescent and Acoustic Mastic

13mm Overlap

Deep Flange “U”

Knauf Wafer Head Screw, to suit specification Knauf Flat Fixing Plate

Plasterboard

Table 3

EI60 Knauf Performer System: Single Layer Plasterboard to both sides

EI 60 Knauf Performer Systems: Single Layer Plasterboard to both sides

1×15mm Knauf Performance Plus

1 × 15mm Knauf Performance Plus (for applications with minimum Knauf 70mm ‘C’ (0.55) studs)

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

1 x 15mm Knauf Fire Panel (for applications with minimum Knauf 70mm ‘C’ (0.55) studs)

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Knauf Performer EI 60 – Single Layer (Insulated Cavity)

Knauf Performer System Deflection Head

Knauf Performer System Deflection Head

Suitable for fire resistance of 60 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

suitable for fire resistance of 60 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm with 25mm Knauf Insulation Acoustic Roll

Approved Fixing, to meet suitability of substrate/loadings

2×19mm

4

Table 4

EI60 Knauf Performer System: Single Layer Plasterboard to both sides

EI 60 Knauf Performer Systems: Single Layer Plasterboard to both sides

1×15mm Knauf Soundshield Plus

1 × 15mm Knauf Soundshield Plus (for applications with minimum Knauf 70mm ‘C’ (0.55) studs)

1×15mm Knauf Performance Plus

1 × 15mm Knauf Performance Plus (for applications with minimum Knauf 70mm ‘C’ (0.55) studs)

Soffit Knauf Angle Section 25×50mm

Knauf Insulation Rocksilk® RS60

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period 13mm Overlap

25mm Knauf Insulation Acoustic Roll

Intumescent and Acoustic Mastic Knauf Deep Flange “U” Channel / 70mm Deep Flange Knauf Wafer Head Screw, to suit specification Knauf Flat Fixing Plate Knauf Metal Stud at maximum 600mm centres size, type and gauge to suit specification

Knauf Plasterboard as per table [4], applied to both sides of the stud

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Table
25mm Knauf Fixing, to suit specification

Knauf Performer EI 60 – Double Layer

Knauf Performer System Deflection Head Suitable for fire resistance of 60 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf Performer System Deflection Head suitable for fire resistance of 60 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm

Approved Fixing, to meet suitability of substrate/loadings

2×19mm Knauf Coreboard

Deflection Allowance Deflection Allowance

Concrete Soffit

13mm Overlap

Knauf Intumescent and Acoustic Mastic Knauf Deep Flange “U” Channel / 70mm Deep Flange

Deflection Allowance

25mm Knauf Fixing, to suit specification

38/42mm Knauf Fixing, to suit specification

Knauf Wafer Head Screw, to suit specification

Flat Fixing Plate

Knauf Plasterboard as per table [5], applied to both sides of the stud

Table 5

Table 5

EI60 Knauf Performer System: Double Layer Plasterboard to both sides

EI 60 Knauf Performer Systems: Double Layer Plasterboard to both sides

2 × 12.5mm Knauf Wallboard

2 × 12.5mm Knauf Moisture Panel

2 × 12.5mm Knauf Soundshield Plus

2 × 15mm Knauf Wallboard

2×12.5mm Knauf Wallboard

2×12.5mm Knauf Moisture Panel

2×12.5mm Knauf SoundShield Plus

2×15mm Knauf Wallboard

2×15mm Knauf Moisture Panel

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Knauf Performer EI 30 – Double Layer (Insulated Cavity)

Knauf Performer System Deflection Head

Suitable for fire resistance of 30 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf Performer System Deflection Head suitable for fire resistance of 60 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm with 25mm Knauf Insulation Acoustic Roll

2×19mm Knauf Coreboard

25mm Knauf Fixing, to suit specification Deflection Allowance Deflection Allowance

38/42mm Knauf Fixing, to suit specification

Approved Fixing, to meet suitability of substrate/loadings

Soffit

Intumescent and Acoustic Mastic

Overlap

Deep Flange “U” Channel / 70mm Deep Flange

Wafer Head Screw, to suit specification

Flat Fixing Plate

Table 6

Table 6

EI60 Knauf Performer System: Double Layer Plasterboard to both sides

EI 30 Knauf Performer Systems: Double Layer Plasterboard to both sides

2×12.5mm Knauf Wallboard

2 × 15mm Knauf Wallboard (for applications with minimum Knauf 70mm ‘C’ (0.55) studs)

2×12.5mm Knauf Moisture Panel

2 × 15mm Knauf Moisture Panel (for applications with minimum Knauf 70mm ‘C’ (0.55) studs)

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

2×12.5mm Knauf Soundshield Plus 2×15mm Knauf Wallboard

2×15mm Knauf Moisture Panel

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Knauf Performer EI 120

Knauf Performer System Deflection Head

Suitable for fire resistance of 120 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Approved Fixing, to meet suitability of substrate/loadings

2×19mm Knauf Coreboard

38/42/45mm Knauf Fixing, to suit specification

Knauf Performer System Deflection Head suitable for fire resistance of 120 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm EI120 Knauf Performer System: Double Layer Plasterboard to both sides

EI 120 Knauf Performer Systems: Double Layer Plasterboard to both sides

2 × 12.5mm Knauf Fire Panel

2 × 12.5mm Knauf Performance Plus

2 × 15mm Knauf Soundshield Plus

2 × 15mm Knauf Fire Panel

2 × 15mm Knauf Performance Plus

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period 13mm Overlap

Plasterboard as per table [7], applied to both sides of the stud

2×12.5mm Knauf Fire Panel

2×12.5mm Knauf Performance Plus

2×15mm Knauf Soundshield Plus 2×15mm Knauf Fire Panel

2×15mm Knauf Performance Plus

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Table 7
Concrete Soffit
Knauf Angle Section 25×50mm
Knauf Intumescent and Acoustic Mastic
Knauf Wafer Head Screw, to suit
Knauf Flat Fixing Plate
Knauf
Table 7

Knauf Performer EI 120 (Insulated Cavity)

Knauf Performer System Deflection Head

Suitable for fire resistance of 120 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf Performer System Deflection Head suitable for fire resistance of 120 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm With 25mm Knauf Insulation Acoustic Roll

Approved Fixing, to meet suitability of substrate/loadings

Table 8

Table 8

EI 120 Knauf Performer Systems: Double Layer Plasterboard to both sides

EI120 Knauf Performer System: Double Layer Plasterboard to both sides 2×12.5mm Knauf Fire Panel

2 × 12.5mm Knauf Fire Panel (for applications with minimum Knauf 70mm ‘C’ (0.55) studs)

2×12.5mm Knauf Performance Plus

2 × 12.5mm Knauf Performance Plus (for applications with minimum Knauf 70mm ‘C’ (0.55) studs)

2×15mm Soundshield Plus 2×15mm Knauf Fire Panel

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

2×15mm Knauf Performance Plus

Knauf Performer Hybrid EI 90 (Insulated Cavity)

Knauf Performer System Deflection Head

Suitable for fire resistance of 90 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Table 6a
EI 90 Knauf Performer System. Double Layer to both sides
2 x 12.5mm Knauf Wallboard (Inner layers) and 2 x 15mm Knauf Fire Panel (outer layers)

Knauf Performer - Hybrid EI 90 (Insulated Cavity)

Knauf Performer System Deflection Head

Suitable for fire resistance of 90 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

EI 90 Knauf Performer System. Double Layer to both sides

2 x 12.5mm Knauf Wallboard (Inner layers) and 2 x 15mm Knauf Soundshield Plus (outer layers)

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Table 6b

Knauf Performer Partition with Knauf Resilient Bar

Knauf Resilient Bar can be added to one side of certain Knauf Performer systems. This additional component improves the acoustic sound reduction performance of the system in order to meet higher acoustic requirements.

Isometric of Knauf Performer with Knauf Resilient Bar

Knauf Resilient Bar – EI 60 (Insulated Cavity)

Knauf Performer System with Resilient Bar to one side Suitable for fire resistance of 60 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf Performer System with Resilient Bar to one side. Deflection Headsuitable for fire resistance of 60 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm With 25mm knauf Insulation Acoustic Roll

Approved Fixing, to meet suitability of substrate/loadings

Concrete Soffit

2×19mm Knauf Coreboard

25mm Knauf Fixing, to suit specification Deflection Allowance Deflection Allowance Deflection Allowance

Knauf Intumescent and Acoustic Mastic

13mm Overlap

Knauf 72mm Deep Flange “U” Channel / 70mm Deep Flange

Knauf Resilient Bar

45mm Knauf Fixing, to suit specification

Knauf Wafer Head Screw, to suit specification

Knauf Flat Fixing Plate

50mm Knauf Insulation Acoustic Roll

Knauf Plasterboard as per table [9], applied to both sides of the stud

Table 9

Table 9

EI 60 Knauf Performer Systems with Resilient Bar to one side : Double Layer Plasterboard to both sides

EI60 Knauf Performer System with Resilient Bar to one side : Double Layer Plasterboard to both sides

2 × 15mm Knauf Soundshield Plus

2×15mm Soundshield Plus

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Knauf

Isolator

(Twin Frame) & Knauf (Twin Frame - Hybrid) Partitions

The Knauf Isolator system is typically used to divide habitable dwellings. The twin stud build up, combined with Knauf’s high performance plasterboards, maximises acoustic performance in order to comply with building regulations, technical handbooks and guidances for sound insulation.

Isometric of Knauf Isolator (Twin Frame) Partition
Isometric of Knauf Isolator (Twin Frame - Hybrid) Partition

Knauf Isolator EI 90 (unbraced

Knauf Isolator System Deflection Head

and braced)

Suitable for fire resistance of 90 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf Isolator System Deflection Head suitable for fire resistance of 60 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm with 2×25mm Knauf Insulation Acoustic Roll

Approved Fixing, to meet suitability of substrate/loadings

2×19mm Knauf Coreboard

Deflection Allowance

Deflection Allowance

Deflection Allowance

Concrete Soffit

Knauf Intumescent and Acoustic Mastic

13mm Overlap

Knauf Deep Flange 'U' Channel Flange length to suit specification

2x25mm Knauf Insulation Acoustic Roll

Knauf Wafer Head Screw, to suit specification

Knauf Plasterboard as per table [14], applied to outer sides of double studs 45mm Knauf Fixing,

Knauf Flat Fixing Plate

Double Knauf 'C' Studs to suit specification at maximum 600mm centres

Table 14

EI 90 Knauf Isolator Systems: Double Layer Plasterboard applied to outer sides of double studs

2 x 15mm Knauf Soundshield Plus

EI60 Knauf Isolator System: Double Layer Plasterboard to both sides 2 x 15mm Knauf Soundshield Plus

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specified Fire resistance period Table 14

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Knauf Isolator Hybrid EI 90

Knauf Isolator System Deflection Head

Suitable for fire resistance of 90 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf Isolator System Deflection Head suitable for fire resistance of 120 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm With 2×25mm Knauf Insulation Acoustic Roll

2×19mm Knauf Coreboard

Soffit Knauf Intumescent and Acoustic Mastic

72mm Deep Flange “U” Channel / 70mm Deep Flange

Wafer Head Screw, to suit specification Knauf Flat Fixing Plate Double Knauf 70mm 'C' (0.55) Studs at maximum 600 mm centres to suit specification

Knauf Plasterboard as per table [15], applied to outer sides of double studs

(mm) to suit

Table 15

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specified Fire resistance period Table 15

EI120 Knauf Isolator System: Double Layer Plasterboard to both sides 1 x 15mm Knauf Soundshield Plus (Inner layer) 1 x 15mm Knauf Performance Plus (Outer layer)

EI 90 Knauf Isolator Systems: Double Layer Plasterboard applied to outer sides of double studs 2 x 15mm Knauf Soundshield Plus (inner layers) and 2 x 15mm Knauf Performance Plus (outer layers) All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Knauf Isolator EI 120 (unbraced and braced)

Knauf Isolator System Deflection Head

Suitable for fire resistance of 120 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf Isolator System Deflection Head suitable for fire resistance of 60 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm with 2×25mm Knauf Insulation Acoustic Roll

Approved Fixing, to meet suitability of substrate/loadings

2×19mm Knauf Coreboard 2x25mm Knauf Insulation Acoustic Roll

Knauf Intumescent and Acoustic Mastic Knauf Deep Flange 'U' Channel Flange length to suit specification Knauf Wafer Head Screw, to suit specification

Knauf Flat Fixing Plate

Double Knauf 'C' Studs to suit specification at maximum 600mm centres

Knauf Plasterboard as per table [15a] applied to both sides of the stud

If specification requires use Knauf Flat Fixing Plate fixed at 1500mm horizontal centres

Table 14

Table 15a

EI 120 Knauf Isolator Systems: Double Layer Plasterboard applied to outer sides of double studs 2 x 15mm Knauf Soundshield Plus

EI60 Knauf Isolator System: Double Layer Plasterboard to both sides 2 x 15mm Knauf Soundshield Plus

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specified Fire resistance period

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Concrete Soffit
Concrete Soffit
Knauf Angle Section 25×50mm

Knauf Shaftwall

Knauf Shaftwall is our innovative system to form enclosures around service and lift shafts while working from one side. The unique Knauf ‘C-T’ Stud makes this possible with a minimum of components. The system can provide a high level of fire resistance performance to meet the requirements of your project.

Isometric of Knauf Shaftwall

Knauf Shaftwall EI 60

Knauf Shaftwall System Deflection Head

Suitable for fire resistance of 60 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf Shaftwall System Deflection Head suitable for fire resistance of 60 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm

Knauf Insulation Rocksilk® RS60

Knauf Angle Section 25×50mm

Deflection Allowance

Approved Fixing, to meet suitability of substrate/loadings

2×19mm Knauf Coreboard

Concrete Soffit

Knauf Intumescent and Acoustic Mastic

Table 10

Deflection Allowance

Knauf Plasterboard as per table [10], applied to one side of the stud

Deflection Allowance 13mm Overlap

Knauf Wafer Head Screw, to suit specification

25mm Knauf Fixing, to suit specification

35mm Knauf Fixing, to suit specification

Knauf Flat Fixing Plate

Knauf Deep Flange “U” Channel / 70mm Deep Flange

Knauf 19mm Coreboard

Knauf Metal 'CT' Stud at maximum 600mm centres, size to suit specification

Knauf Insulation Rocksilk® RS60. Applied depth 300mm

Table 10

EI 60 Knauf Shaftwall System: Double layer plasterboard to Lobby/Room side

2 x 12.5mm Knauf Fire Panel and integral 19mm Knauf Coreboard

EI60 Knauf Shaftwall System: Double Layer Plasterboard to one side 2 x 12.5mm Knauf Fire Panel and (Integral 19mm Coreboard)

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specified Fire resistance period

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Knauf Shaftwall EI 90

Knauf Shaftwall System Deflection Head

Suitable for fire resistance of 90 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf Shaftwall System Deflection Head suitable for fire resistance of 90 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm

Knauf Insulation Rocksilk® RS60

Knauf Angle Section 25×50mm

Deflection Allowance

13mm Overlap

Deflection Allowance

Knauf Plasterboard as per table [11], applied to one side of the stud

Deflection Allowance

Knauf Wafer Head Screw, to suit specification

25mm Knauf Fixing, to suit specification

42mm Knauf Fixing, to suit specification

Knauf Flat Fixing Plate

Approved Fixing, to meet suitability of substrate/loadings

2×19mm Knauf Coreboard

Concrete Soffit

Knauf Intumescent and Acoustic Mastic

Knauf Deep Flange “U” Channel / 70mm Deep Flange

Knauf 19mm Coreboard

Knauf Metal 'CT' Stud at maximum 600mm centres, size to suit specification.

Knauf Insulation Rocksilk® RS60. Applied depth 300mm

Table 11

Table 11

EI 90 Knauf Shaftwall System: Double layer plasterboard to Lobby/Room side

EI90 Knauf Shaftwall System: Double Layer Plasterboard to one side

2 x 15mm Knauf Fire Panel and (Integral 19mm Coreboard)

2 x 15mm Knauf Fire Panel and integral 19mm Knauf Coreboard

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specified Fire resistance period

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Knauf Shaftwall EI 120

Knauf Shaftwall System Deflection Head

Suitable for fire resistance of 120 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf Shaftwall System Deflection Head suitable for fire resistance of 120 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm

Knauf Insulation Rocksilk® RS60

Knauf Angle Section 25×50mm

Deflection Allowance 2×19mm Knauf Coreboard

Concrete Soffit

Knauf Intumescent and Acoustic Mastic

Deflection Allowance

Knauf Plasterboard as per table [12], applied to one side of the stud

Deflection Allowance 13mm Overlap

Knauf Wafer Head Screw, to suit specification

25mm Knauf Fixing, to suit specification

42mm Knauf Fixing, to suit specification

55mm Knauf Fixing, to suit specification

Knauf Flat Fixing Plate

Knauf Deep Flange “U” Channel / 70mm Deep Flange

Knauf 19mm Coreboard

Knauf Metal 'CT' Stud at maximum 600mm centres, size to suit specification

Insulation Rocksilk® RS60. Applied depth 300mm

Table 12

Table 12

EI 120 Knauf Shaftwall System: Double layer plasterboard to Lobby/Room side

EI120 Knauf Shaftwall System: Triple Layer Plasterboard to one side

3 x 15mm Knauf Fire Panel and (Integral 19mm Coreboard)

3 x 15mm Knauf Fire Panel and integral 19mm Knauf Coreboard

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specified Fire resistance period

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Knauf

Knauf Smokeshaft

Knauf Smokeshaft is a system to be used when an A1 fire classification board (in accordance with EN 13501) is required to line a shaft.

Isometric of Knauf Smokeshaft

Knauf Smokeshaft EI 120

Knauf Smokeshaft System Deflection Head

Suitable for fire resistance of 120 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf Smokeshaft System Deflection Head suitable for fire resistance of 120 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm

Approved Fixing, to meet suitability of substrate/loadings

Knauf Insulation Rocksilk® RS60

Knauf Angle Section 25×50mm

Deflection Allowance

Soffit

and Acoustic Mastic

Deep Flange “U” Channel / 70mm Deep Flange

Deflection Allowance

55mm Knauf Fixing, to suit specification

42mm Knauf Fixing, to suit specification

25mm Knauf Fixing, to suit specification

Knauf Wafer Head Screw, to suit specification

Knauf Flat Fixing Plate

Knauf Fireboard

Table 14

Table 13

Fireboard

Metal 'I' Stud at maximum 600mm centres, size, and gauge to suit specification

EI120 Knauf Smokeshaft System: Triple Layer Fibre glass gypsum board to one side

EI 120 Knauf Smokeshaft System: Triple Layer Fibre Glass Gypsum Board to Lobby/room side.

3 x 15mm Knauf Fireboard and (Integral 15mm Fireboard)

3 x 15mm Knauf Fireboard and integral 15mm Knauf Fireboard

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specified Fire resistance period

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Concrete
Knauf Intumescent
Knauf
Knauf
Knauf Insulation Rocksilk® RS60. Applied depth 300mm
Knauf

Knauf ‘I’ Stud Linings

Knauf Independent ‘I’ Stud is a fully independent wall lining system that can be used in all building types to upgrade the acoustic, fire and thermal performance of an existing masonry wall and to deal with any irregularities. Due do the system using an Knauf ‘I’ Stud, there is no requirement for the lining system to be fixed back into the structure behind.

Isometric of Knauf ‘I’ Stud Lining

Knauf ‘I’ Stud Lining EI 60 (Insulated Cavity)

Knauf I Stud Lining System Deflection Head

Suitable for fire resistance of 60 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf I Stud Lining System Deflection Head suitable for fire resistance of EI60 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm

Approved Fixing, to meet suitability of substrate/loadings

2×19mm Knauf Coreboard

Deflection Allowance

NB: Note for Option 1: Only one approved fixing required at required maximum 600mm centres. Illustration represents Option 2.

Deflection Allowance

Deflection Allowance

Knauf Angle Section 25×50mm

Concrete Soffit

Knauf Insulation Rocksilk® RS60

Knauf Intumescent and Acoustic Mastic

13mm Overlap

Table 16

Table 16

EI 60 Knauf I Stud Lining System: Double Layer Plasterboard to one side

2 × 15mm Knauf Fire Panel

1: Knauf 70mm 'I' (0.70) Stud at

centres Or Option 2: Knauf 92mm 'I' (0.90) Stud at maximum 600mm centres

Knauf Wafer Head Screw, to suit specification

25mm Knauf Fixing, to suit specification

42mm Knauf Fixing, to suit specification

Knauf Flat Fixing Plate

Knauf Plasterboard as per table [16]

50mm Knauf Insulation Rocksilk® RS60. Full height of lining system.

EI60 Knauf I Stud Lining System: Double Layer Plasterboard to one side 2×15mm Knauf Fire Panel

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Knauf AQUAPANEL® Indoor Board / Interior System

Knauf AQUAPANEL® Cement Board Indoor is exceptionally tough and durable, providing a solid tile backing substrate for wet indoor areas such as swimming pools, leisure centres, bathrooms and kitchens. The board is used in conjunction with specialist screws and finishing products to provide a full Knauf solution for humid and wet conditions.

Isometric of Knauf AQUAPANEL® Interior System

Knauf AQUAPANEL® EI 30

Knauf AQUAPANEL® Indoor System Deflection Head suitable for fire resistance of 30 minutes (Integrity and Insulation) to BS EN 1364-1 with a maximum deflection allowance of -25mm or +/-12.5mm

Knauf Aquapanel Indoor System Deflection Head suitable for fire resistance of 30 minutes (Integrity and Insulation) to EN 1364-1 with a maximum deflection allowance of -25mm

Approved Fixing, to meet suitability of substrate/loadings

Permanent Flexible Sealant, ’by others’

3×12.5mm Knauf AQUAPANEL® Indoor

25mm Knauf AQUAPANEL® Maxi Screws (SN) Deflection Allowance

Intumescent and Acoustic Mastic

13mm Overlap

Knauf Wafer Head Screw, to suit specification

25mm Knauf Insulation Acoustic Roll

Table 16

Table 17

EI 30 Knauf AQUAPANEL® Indoor System: Single Layer Cement Board to both sides

EI30 Knauf Aquapanel Indoor System: Single Layer Cement board to both sides 1×12.5mm Knauf Aquapanel® Indoor

1 × 12.5mm Knauf AQUAPANEL® Cement Board Indoor

All Knauf Cement board listed are suitable for use, in the arrangements shown above for the specific fire resistance period

All Knauf Plasterboards listed are suitable for use, in the arrangements shown above for the specific fire resistance period

Knauf
Knauf 72mm Deep Flange “U” Channel / 70mm Deep Flange
Knauf 70mm Acoustic 'C' (0.6) Stud at 600mm centres
Knauf 12.5mm AQUAPANEL® Indoor
Knauf Flat Fixing Plate Concrete Soffit

CUSTOMER SERVICE

UK: 0800 521 050 Eire: 01 4620739 cservice@knauf.com

TECHNICAL SERVICE

0800 521 050 (press option 2) technical-uk@knauf.com

LITERATURE

UK: 03700 613 700 Eire: +44 3700 613 700

ADDRESSES

Knauf Kemsley Fields Business Park Sittingbourne Kent ME9 8SR

Knauf 87 Broomhill Road Tallaght Dublin 24 D24 WR85

WEBSITE

knauf.com knauf.ie

SOCIAL MEDIA /KnaufUK

@Knauf_UK

Knauf UK & Ireland

@Knauf_UK

Creation Date: 29/04/2024

Revision Reference: 003

Revision Date: 01/10/2024

Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.