full_eng

Page 1

GAS CONVECTOR FULL

Apen Group Trademark


WHAT

KIND OF CONVECTOR?

FULL, the first-class gas convector thanks to its harmonious design and its capacity to make the ambient comfortable, is suitable to heat in few minutes and in total safety home, public and commercial environments.

WORKING PRINCIPLES The FULL convector is an appliance with a sealed combustion chamber: this means that the combustion air inlet and the flue discharge are outside the ambient to be heated, avoiding the danger of blowing in the ambient the combustion products.

FULL: MORE HEAT WHENEVER AND

WHEREVER NEEDED

4

MODELS 5 3

FULL is available in three versions, according to the needed heat: FULL 30

heat output kW 3,07

FULL 40

heat output kW 4,19

FULL 60

heat output kW 5,78

5 2

Three further special versions with similar heat output are available with shells whose temperature does not overcome 60째C.

The FULL convectors have been studied to work both with natural gas and with LPG.

7

1

4

All the convectors are delivered preset for operation with natural gas, and complete of the fitting LPG kit.

3 6

1 The ambient air is drawn by the fan (2) through the inferior grilles of the shell (1) and gets warm in contact with the combustion chamber and the heat exchanger (3). The warm air is then blown into the ambient through the upper grilles of the shell (4). The sealed combustion circuit takes the combustion air from the outside (5). The premix burner (6) ensures an optimum combustion. Then the gases are discharged through the exhaust pipe (7).


TECHNICAL FEATURES

Thermostat Lock/reset switch

• The combustion is constant and very well set: since the forced draught and the premix burner reduce the polluting emissions. • The fuel consumption is at the minimum: since the gas flow to the burner is controlled by a double valve which also controls the output power supplied by the burner.

warning light Min/max switch

• The safety is total: since the chamber is sealed and the ignition is electronic: failing the flame signal, a safety ionization device cuts off the gas flow.

On/off switch

• Long life is guaranteed: since the combustion chamber and the heat exchanger are made in stainless steel. • The right degree of humidity is maintained and consequently the well-being: since Full is fitted with an inside humidifier that must be daily filled with water.

The temperature is constant and guaranteed by the thermostat. The settings and the checks are easy to be performed: on/off switch, warning light and unlock button.

Time clock

You can choose among two working power levels, assuring in this way more comfort, noiselessness and energy saving.

Humidifier (refillable from above)

Heat exchanger

Centrifugal fan group and premix

Combustion

gas burner

chamber Ventilation

Valve group

tangential fan

and electronic card


WHERE TO INSTALL THE FULL CONVECTOR Full can be installed on every part of the wall: If the wall communicates directly to the outside, the template reproducing the real dimensions of the convector and the standard coaxial pipes make the installation easy and quick.

If the wall does not communicate directly to the outside, the template and the suitable accessories must always be used: coaxial pipe with 90째 discharge, or separate discharge pipes.

The separate pipes and the appropriate pipe fitting allow the flue discharge and the combustion air intake in 4 directions. Besides, the combustion air can be taken in also from the rear side of the convector.

In order to facilitate the check and maintenance operations, the minimum suggested distances for the installation are 100 mm from the pavement and 250 mm from the side walls.


SAFETY AND COMFORT

ACCESSORIES

ARE ASSURED The accessories can meet any need of installation, making it easy and quick. Thanks to the room sealed combustion circuit, no ambient air is used for the combustion, assuring a safe and healthy ambient for the people.

It is possible to choose among two different capacity levels of the gas convector. The high capacity, and high fan speed, ensures a quick heating of the ambient. The low capacity, and low fan speed, maintains the desired room temperature ensuring the maximum acoustic comfort.

THE

Timer

SUPPLIED HEAT

IS IN CONFORMITY WITH THE FOLLOWING

NORMS Coaxial pipe extension kit

Gas Directive 90/396/CEE of 29/6/90 Low Voltage Directive 93/68/CEE of 22/07/93 EMC Directive 92/31/CEE of 28/04/92

90째 coaxial separate discharge pipe fitting

Template support panel for 90째 coaxial separate discharge

Elbow


TECHNICAL FEATURES

Model CE Approval Type of appliance(*) Nominal Heat Input kW

PIN

min. max. Heat Output kW min. max. Efficiency % max. min. Methane G20 consumption (15°C 1013 mbar) m3/h min. max. Butane G30 consumption (15°C 1013 mbar) kg/h min. max. Ø Concentric air inlet/exhaust pipe Ø Separate air inlet/exhaust pipe Max. length concentric pipes Max. length separate pipes Supply Voltage V/F/Hz Absorbed Electrical Power Noise Level (3m) dB(A) min. max.

F30

F40

F60

0063AR4672 C12-C52 2,4 3,4 2,11 3,07 90,2 88 0,255 0,360 0,154 0,218 50/35 35/35 1 6+6 230/~/50 80 35 38

0063AR4672 C12-C52 3,0 4,6 2,67 4,19 91 89 0,318 0,488 0,192 0,295 50/35 35/35 1 4+4 230/~/50 80 35 40

0063AR4672 C12-C52 4,3 6,4 3,79 5,78 90,3 88,1 0,465 0,672 0,280 0,406 50/35 35/35 0,8 6+6 230/~/50 100 36 41

(*) The configuration C12 is standard; upon request, the configuration C52 with accessories is available.

Model CE Approval Type of appliance(*) Nominal Heat Input kW

PIN

min. max. Heat Output kW min. max. Efficiency % max. min. Methane G20 consumption (15°C 1013 mbar) m3/h min. max. Butane G30 consumption (15°C 1013 mbar) kg/h min. max. Ø Concentric air inlet/exhaust pipe Ø Separate air inlet/exhaust pipe Max. length concentric pipes Max. length separate pipes Supply Voltage V/F/Hz Absorbed Electrical Power Noise Level (3m) dB(A) min. max.

F48

F66

F68

0063AR4672 C12-C52 2,4 3,2 2,15 2,91 91,0 89,7 0,255 0,338 0,154 0,212 50/35 35/35 1 6+6 230/~/50 80 35 38

0063AR4672 C12-C52 2,4 3,2 2,18 2,95 92,3 90,8 0,255 0,338 0,154 0,212 50/35 35/35 1 6+6 230/~/50 100 35 39

0063AR4672 C12-C52 3,0 4,6 2,69 4,23 91,9 89,5 0,318 0,488 0,190 0,295 50/35 35/35 1 4+4 230/~/50 100 35 40

Appliances with shells whose surface temperature does not overcome 60°C (F66) and 85°C (F48,F68). (*) The configuration C12 is standard; upon request, the configuration C52 with accessories is available.


DIMENSIONS

Model

Overall dimensions

F30 F40 F60 F48 F66 F68

A 578 730 1020 730 1020 1020

B 554 554 554 554 554 554

C 206 206 206 206 206 206

Chimney hole position E 369 521 781 521 781 781

F 209 209 239 209 239 239

G 380 380 380 380 380 380

Minimum distances H 174 174 174 174 174 174

P ≥100 ≥100 ≥100 ≥100 ≥100 ≥100

S SIDES ≥100 ≥250 ≥100 ≥250 ≥100 ≥250 ≥100 ≥250 ≥100 ≥250 ≥100 ≥250

Weight KG 23 27 35 27 35 35

A E

C

F

G

Ø 50 Ø 35

B

S

H

35

P

70

Gas

DIMENSIONS WITH

SUPPORT PANEL

When the 90° coaxial discharges are used, it is necessary to utilize the template for coaxial discharge.

CK K Model

F30 F40 F60 F48 F66 F68

Overall dimensions CK 308 308 308 308 308 308

K 100 100 100 100 100 100


INSTALL THEM WHEREVER

Where a central heating system is not wished, the FULL convector, with a simple and easy wall installation, guarantees the comfort of a big system.

FULL can be installed in:

In fact, FULL is a little autonomous heater producing heat through the combustion produced by the gas burner inside the little combustion chamber, which is completely sealed.

* Shops

LIVING-ROOM

OFFICE

* Offices * Holiday houses

* Cellars * One-roomed flat * Surgery As an alternative in installations with a traditional heating system, to be used during mid-seasons

BEDROOM

APEN GROUP s.p.a. 20060 Pessano con Bornago (MI) Via Provinciale, 85 Tel. +39.02.9596931 Fax +39.02.95742758 Internet: http://www.apengroup.com E-mail: apen@apengroup.com Export Department: Tel. +39-02-95.96.93.555

BATHROOM

X01996GB ed 03/00 - Specifications in this catalogue are subject to change without notice, in order that Apen Group may bring the latest innovation to its customers.

The sealed combustion chamber is the best safety and warranty for people living in the ambient, since the combustion air intake and the flue discharge occur completely outside.

P UBLITRUST • M O N Z A

03-00ING

YOU WANT


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.