Measurement_cover_Final.pdf 1 14/11/2012 12:41:06 PM
C
M
Y
CM
MY
CY
CMY
K
54 Lakewood Boulevard, Carrum Downs Victoria, 3201 AUSTRALIA T: +613 9775 1186
F: +613 9775 1187
Customer Service Centre T: 1300 300 747
F: 1300 300 074
www.wattmaster.com.au
TEST AND MEASUREMENT
Important Information: Whilst every precaution is taken to ensure the information contained herein is correct, Wattmaster accepts no liability whatsoever for errors or omissions. In the interest of continuous improvement, Wattmaster reserves the right to change the specifications or design of any of its products without prior notice. Š Copyright 2012
Safety demands IEC 61010-1 As a professional user of test- and measuring equipment, your instruments must fulfill current norms and guidelines. This includes CE standard, EMC and IEC10101/EN61010-1. Especially when measuring voltage and current is to be measured, it’s important to fulfill IAC 1010-1 for correct category. This information are applied to all relevant instruments, for example IEC 1010-1 CatIII 300V. Please be aware that the indi-
CAT
I
CAT
II
cated voltage is not the maximum voltage to be measured, but the maximum potential to ground. This will be 230V in standard household installations. The Low voltage directive (LVD) describes safety required when measuring. If the equipment fulfill IEC61010-1 / EN61010 and corresponding category, the LVD is said to be fulfilled.
CAT
CAT
III
IV
Main switchboard Meter
Shack Main switchboard
Meter
Earth bond
Shack Main switchboard
Transformer Meter
Earth bond
Example:
CAT I
CAT II
CAT III
CAT IV
Electronic equipment and household appliances with low energy consumption
Outlets and sockets more than 10 meters from Cat III or 20 meters from Cat IV and household appliances
Switch boards, fuse boxes and electrical installations.
Supply lines and overhead power lines, outdoor installations and cables in the ground.
Elma 525 IEC 61010-1 Cat IV 1000V
Note: The indicated voltage is the maximum allowed potential between the instrument and neutral ground. Ie. that a 300V instrument can be used to measure 400V line to line voltage, because the potential to neutral ground is only 230V.
Methods of measuring – ground resistance It’s important to verify the resistance to ground. Worst case scenario is injury or death, if the resistance to ground is not ok. There are values and norms to fulfill. Therefore it’s important to be able to test and measure all connections and resistance to ground. When measuring the resistance of earth bonds, one of the below methods are typically used.
R S T N
S (Y) E (X)
PE
RH
RT
H (Z)
TERRE EXISTANTE
0%
62%
100%
GOOD TO KNOW - EARTH LOOP RESISTANCE
GOOD TO KNOW - THREE CONNECTION MEASUREMENT
This method demands a connection to line and neutral, as it is the earth bond of the grid that are used as reference. Known as the two connection earth loop measurement.
The 62% method is the most precise method to measure resistance to earth. The distance from E to H must be at least 5 times the length of the earth rod. For example if the rod is 2 meters in the ground, the distance between E and H must at least be 10 meters. The distance from E to S is 62% of the total distance, in this example 6,2 meters.
It’s as easy and fast method, and no external probes are needed. The loop is measured through the grid and the transformer grounding. That means that the value will typically be slightly higher than the clean resistance to earth from the rod.
Note: In large earth systems the diameter of the earth system is to seen as the length of the earth rod.
Because of this the method is not suitable if a precise resistance is required. Be aware that the result should be stable, if controlled by moving the S rod to 10% more and then 10% less than 62%.
E (X)
H (Z)
S (Y)
ES (XV) D
D
E (X)
H (Z)
S (Y)
ES (XV) A
D D
D
GOOD TO KNOW - EARTH RESISTIVITY
SCHLUMBERGER METHOD
The earth rod should be established where the earth conductivity is best. This can be controlled by using the Wenner or the Schlumberger method. The unit for this type of measurement is Ohmmeter. The CA6472 (page 61) automatically calculate the result, the only information necessary for the instrument is the distance between the rods.
Used to determine the vertical conductivity and if it would be an advantage to extend the rod deeper in the ground. When the distance between the outer rods, E and H is extended, the measuring depth is extended. The distance between the inner rods is A.
WENNER METHOD
Used to define the lateral placement of the earth rod. This identifies the best place along a line to place the rod. The distance D between the rods must be the same. ρW = 2 x π x d x RS - ES
The distance between the outer rods is 2 times D. ρS = ( π x (d2 -A2 / 4) x RS - ES) / 4
TABLE OF CONTENTS MULTIMETERS POCKET DIGITAL MULTIMETER - WATTMASTER .......................................................................................................... 5 DIGITAL MULTIMETER - SAGAB....................................................................................................................................... 6 AUTO CHECK AC/DC DIGITAL MULTIMETER - ELMA .................................................................................................... 7 AC/DC DIGITAL MULTIMETER - WATTMASTER.............................................................................................................. 8 DIGITAL MULTIMETER - THEO BENNING........................................................................................................................ 9 STANDARD MM 400V AC/DC - ELMA ............................................................................................................................. 10 RMS MULTI METER WITH TEMP -20 - 300°C - ELMA.................................................................................................... 11 RMS W/AUTO CHECK, PC CONNECTIVITY & TEMP CATIII - ELMA ............................................................................ 12 1000V TRUE RMS AUTO CHECK W/PC CONNECTIVITY CATIV - ELMA ..................................................................... 13 INSULATION TESTER WITH MULTIMETER - ELMA ...................................................................................................... 14 DIGITAL MULTIMETER - WATTMASTER........................................................................................................................ 14 ANALOGUE MULTIMETER - WATTMASTER.................................................................................................................. 15 2-IN-1 INSULATION TESTER & MULTIMETER - ELMA .................................................................................................. 16 TEST LEADS SET FOR MULTIMETERS AND CLAMP METERS - WATTMASTER ....................................................... 17
CLAMP METERS MINI DIGITAL CLAMP METER - WATTMASTER............................................................................................................. 17 MULTIFUNCTION DIGITAL METER - WATTMASTER .................................................................................................... 18 DIGITAL CLAMP MULTIMETER - WATTMASTER .......................................................................................................... 18 DIGITAL MULTIMETER - THEO BENNING...................................................................................................................... 19 DIGITAL CLAMP METER - ELMA..................................................................................................................................... 20 POWERCLAMP™ CLAMP METER - ELMA ..................................................................................................................... 21 CLAMP METER 200A OPEN JAW - ELMA ...................................................................................................................... 21 CLAMP METER 400A AC - ELMA .................................................................................................................................... 22 CLAMP METER 400A AC TRUE RMS - ELMA ................................................................................................................ 23 AC/DC DIGITAL CLAMP METER - ELMA ........................................................................................................................ 24 AUTO CHECK CLAMP-ON MULTIMETER - ELMA.......................................................................................................... 25 MINI DIGITAL CLAMP METER - ELMA ............................................................................................................................ 26 CLAMP METER 400A AC/DC TRUE RMS MINI - ELMA.................................................................................................. 26 DIGITAL CLAMP-ON METER - ELMA .............................................................................................................................. 27 TEST LEADS SET FOR MULTIMETERS AND CLAMP METERS - WATTMASTER ....................................................... 27
INSULATION TESTERS ANALOGUE INSULATION TESTER - WATTMASTER .................................................................................................... 28 ANALOGUE INSULATION RESISTANCE TESTER - WATTMASTER ............................................................................ 28 ANALOGUE INSULATION TESTER - WATTMASTER .................................................................................................... 29 ANALOGUE INSULATION TESTER WITH RECHARGABLE BATTERY - ELMA ............................................................ 29 ANALOGUE INSULATION TESTER WITH 9V BATTERY - ELMA................................................................................... 30 2-IN-1 INSULATION TESTER & MULTIMETER - ELMA .................................................................................................. 31 INSULATION TESTER WITH MULTIMETER - ELMA ...................................................................................................... 32 DIGITAL RCD TESTER - ELMA........................................................................................................................................ 32
3
TABLE OF CONTENTS VOLTAGE TESTERS COMPACT VOLTAGE TESTER - THEO BENNING......................................................................................................... 33 EXPERT VOLTAGE TESTER - THEO BENNING ............................................................................................................ 33 DIGITAL PLUS VOLTAGE TESTER - THEO BENNING .................................................................................................. 34 ELECTRICAL VOLTAGE TESTER - WATTMASTER....................................................................................................... 35 AC/DC VOLTAGE TESTER - ELMA ................................................................................................................................. 35 VOLTAGE TESTER 690V AC/DC CAT IV 300V - ELMA.................................................................................................. 36 TEST SCREWDRIVERS/VOLTAGE TESTERS - WITTE ................................................................................................. 36
OTHER TESTERS VS3 TRACKER/TROUBLESHOOTER - SAGAB .............................................................................................................. 37 POWER POINT AND EARTH LEAKAGE TESTER - WATTMASTER.............................................................................. 37 CABLE TRACER - WATTMASTER................................................................................................................................... 38 CIRCUIT BREAKER IDENTIFIER & FAULT FINDER - WATTMASTER .......................................................................... 38 CIRCUIT BREAKER IDENTIFIER 220-240VAC - WATTMASTER................................................................................... 39 LUX & FC LIGHT METER - WATTMASTER..................................................................................................................... 39 LIGHT METER 200LUX - ELMA ....................................................................................................................................... 40 INFRARED THERMO W/DOUBLE LASER 600째C - ELMA............................................................................................... 40 INFRARED THERMO W/DOUBLE LASER 1000째C - ELMA............................................................................................. 41 WIRELESS ENERGY CONTROL MONITOR - WATTMASTER....................................................................................... 41 TACHOMETER PHOTO/CONTACT - ELMA .................................................................................................................... 42
VOLT STICKS VOLT STICK - SAGAB ...................................................................................................................................................... 42 MAGNET FIELD INDICATOR - SAGAB............................................................................................................................ 43 VOLT STICK FLAT TIP - SAGAB...................................................................................................................................... 43 VOLT STICK PRO - SAGAB ............................................................................................................................................. 44 VOLT STICK PRO 230 - SAGAB ...................................................................................................................................... 44 INTRINSICALLY SAFE VOLT STICK - SAGAB................................................................................................................ 45 50V VOLT STICK - SAGAB............................................................................................................................................... 45
4
MULTIMETERS POCKET DIGITAL MULTIMETER ‐ WATTMASTER FEATURES
• Non‐contact voltage indicator with sound. • Pocket sized. • Convenient built‐in case for easy storage of test leads. • Built‐in test stand and auto power off. • Auto‐ranging. • Overload protection. • Bargraph display. Measuring circuit category: Display count: Indication: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Min resistance measuring range: Max resistance measuring range: Continuity resistor: Diode test: NCV indication range: Dimensions: Weight: Inclusion:
CAT II 600V, CAT III 300V 3 1/2 digit, 3400 Digital 3.4 V 600 V 340 mV 600 V 340 Ohm 34 MOhm 340 Ohm 2V 70 ... 600 V 125x60x24mm 100 g Operating instructions
Part No. WAT115A
5
MULTIMETERS DIGITAL MULTIMETER ‐ SAGAB FEATURES
• Pocket sized multimeter with non‐contact voltage detection. • Auto‐ranging and auto power off. • Test probes can be attached to back of meter when not in use. • Battery indication and handy back light for dim areas. Measuring circuit category: Display count: Indication: Lowest resolution, AC voltage: Max voltage measuring range, AC: Max voltage measuring range, DC: Lowest resolution, AC current: Max current measuring range, AC: Lowest resolution, DC current: Max current measuring range, DC: Min resistance measuring range: Max resistance measuring range: Min frequency measurement: Max frequency measurement: Min. capacitance measuring range: Max capacitance measuring range: NCV indication range: Frequency measurement: Dimensions: Weight: Inclusion:
CAT III 1000V 3 3/4 digit, 4000 Digital 4V 600 V 600 V 400 µA 0.2 A 400 µA 0.2 A 400 Ohm 40 MOhm 10 Hz 10 kHz 4 nF 200 µF 4 ... 600 V Yes 104x55x32.5mm 145 g Test leads, battery, carry case & instructions
Part No. WATDMM904
6
MULTIMETERS AUTO CHECK AC/DC DIGITAL MULTIMETER ‐ ELMA FEATURES
• Intelligent 'auto check' feature automatically detects and selects AC/DC voltage function etc. • Auto‐ranging and auto power off. • Data hold function and overload protection. • With non‐contact voltage indication. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, batteries, carry case and operating instructions. Measuring circuit category: Display count: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Lowest resolution, resistance: Max resistance measuring range: Min frequency measurement: Max frequency measurement: Min. capacitance measuring range: Max capacitance measuring range: Min continuity resistor range: Max continuity resistor range: NCV indication range: Frequency measurement: Dimensions: Weight:
CAT II 600V, CAT III 300V 3 5/6 digit, 6000 6V 600 V 6V 600 V 600 Ohm 40 MOhm 10 Hz 100 kHz 100 nF 2000 µF 50 Ohm 300 Ohm 15 ... 190 V Yes 113x53x10mm 80 g
Part No. WATEL-25
7
MULTIMETERS AC/DC DIGITAL MULTIMETER ‐ WATTMASTER FEATURES
• Hand held digital meter with ruggedised body for shock protection. • Fuse protected. • Safety input jacks. • Overload protection. • Wrong input buzzer warning. Measuring circuit category: Display count: Indication: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Lowest resolution, AC current: Max current measuring range, AC: Lowest resolution, DC current: Max current measuring range, DC: Min resistance measuring range: Max resistance measuring range: Min frequency measurement: Max frequency measurement: Continuity resistor: Diode test: Frequency measurement: Dimensions: Weight: Inclusion:
CAT III 1000V 3 1/2 digit, 1999 Digital 200 mV 750 V 200 mV 1000 V 200 µA 20 A 200 µA 20 A 200 Ohm 2000 MOhm 2 kHz 40 kHz 100 Ohm 2V Yes 198x90x44mm 400 g Test leads, spare fuse & instructions
Part No. WATDMM9001
8
MULTIMETERS DIGITAL MULTIMETER ‐ THEO BENNING FEATURES
• Pen‐type multimeter with AC current transducer. • Auto‐ranging. • Low battery warning. • Robust housing due to integrated protective rubber frame. • IEC 61010‐1. • IP30 rating. Measuring circuit category: Display count: Indication: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Max current measuring range, AC: Min resistance measuring range: Max resistance measuring range: Continuity resistor: Diode test: Pliers opening: Dimensions: Weight: Inclusion:
CAT III 300V 3 3/4 digit, 4200 Digital 4.2 V 600 V 4.2 V 600 V 300 A 420 Ohm 42 MOhm 50 Ohm 1V 30 mm 145x52x34mm 100 g Test leads, battery, carry case & instructions
Part No. WAT044073
9
MULTIMETERS STANDARD MM 400V AC/DC ‐ ELMA FEATURES
• Professional grade, rugged test meter. • Measures Voltage, Current, Frequency, Resistance, Capacitance, Diodes and Continuity. • Faulty Connection Warning. • Highly efficient fuses. • Automatic Range Selection. • Relative Measurement. • Max & Data Hold. • Compliant with IEC 61010‐1 CAT III 600V. • Supplied complete with manual, battery, test leads and robust rubber protective cover. Measuring circuit category: Display count: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Lowest resolution, AC current: Max current measuring range, AC: Lowest resolution, DC current: Max current measuring range, DC: Lowest resolution, resistance: Max resistance measuring range: Min frequency measurement: Max frequency measurement: Min. capacitance measuring range: Max capacitance measuring range: Min continuity resistor range: Max continuity resistor range: Diode test: Dimensions: Weight:
CAT III 600V, CAT II 1000V 3 3/4 digit, 4000 400 mV 1000 V 400 mV 1000 V 400 µA 10 A 400 µA 10 A 400 Ohm 40 MOhm 50 Hz 1 MHz 500 nF 3000 µF 10 Ohm 120 Ohm 1.6 V 186x87x45mm 390 g
Part No. WATEL-805
10
MULTIMETERS RMS MULTI METER WITH TEMP ‐20 ‐ 300DEG ‐ ELMA FEATURES
• Handheld digital meter with ruggedised body. • Auto‐ranging and auto power off. • Data hold function and overload protection. • Wrong input warning. • Highly efficient fuses. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, batteries, carry case and operating instructions. Measuring circuit category: Display count: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Lowest resolution, AC current: Max current measuring range, AC: Lowest resolution, DC current: Max current measuring range, DC: Lowest resolution, resistance: Max resistance measuring range: Min frequency measurement: Max frequency measurement: Min. capacitance measuring range: Max capacitance measuring range: Temperature range: Min continuity resistor range: Max continuity resistor range: Diode test: Dimensions: Weight:
CAT III 600V, CAT II 1000V 3 3/4 digit, 4000 400 mV 1000 V 400 mV 1000 V 400 µA 10 A 400 µA 10 A 400 Ohm 40 MOhm 50 Hz 1 MHz 500 nF 3000 µF -20 ... 300 °C 10 Ohm 120 Ohm 1.6 V 198x97x55mm 400 g
Part No. WATEL-807
11
MULTIMETERS RMS W/AUTO CHECK, PC CONNECTIVITY & TEMP CATIII ‐ ELMA FEATURES
• Handheld digital meter with ruggedised body. • Auto‐ranging and auto power off. • Data hold function and overload protection. • Wrong input warning. • True RMS and temperature measurement. • Highly efficient fuses and handy backlight for dim areas. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, batteries, carry case and operating instructions. Measuring circuit category: Display count: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Lowest resolution, AC current: Max current measuring range, AC: Lowest resolution, DC current: Max current measuring range, DC: Lowest resolution, resistance: Max resistance measuring range: Min frequency measurement: Max frequency measurement: Min. capacitance measuring range: Max capacitance measuring range: Temperature range: Min continuity resistor range: Max continuity resistor range: Diode test: NCV indication range: Dimensions: Weight:
CAT III 600V 3 5/6 digit, 6000 60 mV 1000 V 60 mV 1000 V 600 µA 8A 600 µA 8A 600 Ohm 60 MOhm 10 Hz 100 kHz 60 nF 3000 µF -50 ... 1000 °C 10 Ohm 80 Ohm 1V 20 ... 1000 V 161x80x50mm 340 g
Part No. WATEL-BM257
12
MULTIMETERS 1000V TRUE RMS AUTO CHECK W/PC CONNECTIVITY CATIV ‐ ELMA FEATURES
• Handheld digital meter with ruggedised body. • Intelligent 'auto check' feature automatically detects and selects AC/DC voltage function etc. • Auto‐ranging and auto power off. • With PC connection‐ can be used for data logging purposes. • Data hold function and overload protection. • True RMS and temperature measurement. • Highly efficient fuses and handy backlight for dim areas. • With non‐contact voltage indication. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, rubber cover, batteries, temperature sensor and operating instructions. Measuring circuit category: Display count: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Lowest resolution, AC current: Max current measuring range, AC: Lowest resolution, DC current: Max current measuring range, DC: Lowest resolution, resistance: Max resistance measuring range: Min frequency measurement: Max frequency measurement: Min. capacitance measuring range: Max capacitance measuring range: Temperature range: Min continuity resistor range: Max continuity resistor range: Diode test: NCV indication range: Dimensions: Weight:
CAT IV 1000V 4 digit, 9999 60 mV 1000 V 60 mV 1000 V 600 µA 10 A 600 µA 10 A 600 Ohm 60 MOhm 10 Hz 100 kHz 60 nF 25 mF -50 ... 1000 °C 20 Ohm 300 Ohm 2V 20 ... 440 V 208x103x65mm 640 g
Part No. WATEL-BM829
13
MULTIMETERS INSULATION TESTER WITH MULTIMETER ‐ ELMA FEATURES
• 2‐in‐1 multimeter and insulation tester. • Handheld digital meter with ruggedised body. • Low battery indication. • Auto‐ranging and auto power off. • Easy to read illuminated display screen. • Data hold function and overload protection. • Automatic discharge of capacitive voltage. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, rubber cover, batteries, carry case and operating instructions. Measuring circuit category: Max voltage measuring range, AC: Max voltage measuring range, DC: Min resistance measuring range: Lowest resolution, resistance: Max resistance measuring range: Min continuity resistor range: Max continuity resistor range: Insulation resistance measuring range: Data hold: Dimensions: Weight:
CAT III 1000V, CAT IV 600V 750 V 1000 V 0 Ohm 40 Ohm 0.0004 MOhm 40 Ohm 400 Ohm 4 ... 4000 MOhm Yes 200x92x50mm 700 g
Part No. WATEL-DT5500A
DIGITAL MULTIMETER ‐ WATTMASTER FEATURES
• Ideal as a first multimeter. • Compact size. • Transistor and battery test. • Overload protection. • Low battery indication. Measuring circuit category: Display count: Indication: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Lowest resolution, DC current: Max current measuring range, DC: Min resistance measuring range: Max resistance measuring range: Temperature range: Continuity resistor: Diode test: Temperature measurement: Dimensions: Weight: Inclusion:
CAT II 500V 3 1/2 digit, 1999 Digital 200 V 750 V 200 mV 1000 V 200 µA 10 A 200 Ohm 2 MOhm -40 ... 1000 °C 70 Ohm 2.4 V Yes 150x70x24mm 150 g Test leads & instructions
Part No. WATQM-1500
14
MULTIMETERS ANALOGUE MULTIMETER ‐ WATTMASTER FEATURES
• Easy to read three colour scale for error‐proof readings. • With built‐in test stand. • Transistor test. • Fuse and diode protection. Measuring circuit category: Indication: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Lowest resolution, DC current: Max current measuring range, DC: Min resistance measuring range: Max resistance measuring range: Continuity resistor: Dimensions: Weight: Inclusion:
CAT II 1000V Analogue 10 V 1000 V 100 mV 1000 V 50 µA 10 A 20 Ohm 0.2 MOhm 120 Ohm 148x100x35mm 280 g Test leads, battery & instructions
Part No. WATQM-1020
15
MULTIMETERS 2‐IN‐1 INSULATION TESTER & MULTIMETER ‐ ELMA FEATURES
• 2‐in‐1 insulation tester and multimeter. • Large backlight display allows for all measurements to be viewed at the same time. • Low battery indication and data hold function. • Auto‐ranging and auto power off. • True RMS. • Store and recall button allows you to store values and recall them later. • With PC connection ‐ can be used for data logging purposes. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, batteries, USB cable, software, carry case and operating instructions. • Protection class: IP67 (dust‐tight/liquid‐tight) Measuring circuit category: Display count: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Lowest resolution, AC current: Max current measuring range, AC: Lowest resolution, DC current: Max current measuring range, DC: Lowest resolution, resistance: Max resistance measuring range: Min frequency measurement: Max frequency measurement: Min. capacitance measuring range: Max capacitance measuring range: Temperature range: Continuity resistor: Min continuity resistor range: Max continuity resistor range: Diode test: Frequency measurement: Dimensions: Weight:
CAT III 1000V, CAT IV 600V 10 digit, 40000 400 mV 1000 V 400 mV 1000 V 400 µA 10 A 400 µA 10 A 400 Ohm 40 MOhm 40 Hz 100 MHz 40 nF 40 mF -50 ... 1000 °C 400 Ohm 35 Ohm 400 Ohm 2.8 V Yes 220x97x61mm 630 g
Part No. WATEL-5800
16
MULTIMETERS TEST LEADS SET FOR MULTIMETERS AND CLAMP METERS ‐ WATTMASTER
FEATURES
• Test lead set for Wattmaster WATDMM and WATDCM range of meters. Type of accessory:
Testlead
Part No. WATTLS
CLAMP METERS MINI DIGITAL CLAMP METER ‐ WATTMASTER FEATURES
• Clamp meter with non‐contact voltage detection. • True RMS and auto power off. • Auto‐ranging and data hold function. • Overload protection. • Handy backlight for dim areas. Measuring circuit category: Display count: Indication: Pliers opening: Current measurement range, AC: Min resistance measuring range: Max resistance measuring range: Min. capacitance measuring range: Max capacitance measuring range: Temperature range: Continuity resistor: NCV indication range: Type of current: Voltage measurement, DC: Voltage measurement, AC: True RMS measurement: Resistance measurement range: Capacitance measurement: Dimensions: Weight: Inclusion:
CATIII 300V, CAT III 600V 3 3/4 digit, 3999 Digital 30 mm 40 ... 400 A 0 Ohm 4 MOhm 4 µF 4 mF -35 ... 400 °C 400 Ohm 24 ... 600 V Alternating current Yes Yes Yes Yes Yes 200x65x39mm 200 g Test leads, carry case & instructions
Part No. WATDCM1046
17
CLAMP METERS MULTIFUNCTION DIGITAL METER ‐ WATTMASTER
FEATURES
• Clamp meter with non‐contact voltage detection. • True RMS and auto power off. • Data hold function. • Overload protection. Indication: Contact less:
Digital Yes
Part No. WATDCM1065
DIGITAL CLAMP MULTIMETER ‐ WATTMASTER
FEATURES
• Ruggedised body for shock absorption. • Auto‐ranging and auto power off. • Data hold function. • Overload protection on all ranges. • True RMS. Indication: Voltage type: True RMS measurement:
Digital AC/DC Yes
Part No. WATDCM2606
18
CLAMP METERS DIGITAL MULTIMETER ‐ THEO BENNING FEATURES
• Pen‐type multimeter with AC current transducer. • Auto‐ranging. • Low battery warning. • Robust housing due to integrated protective rubber frame. • IEC 61010‐1. • IP30 rating. Measuring circuit category: Display count: Indication: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Max current measuring range, AC: Min resistance measuring range: Max resistance measuring range: Continuity resistor: Diode test: Pliers opening: Dimensions: Weight: Inclusion:
CAT III 300V 3 3/4 digit, 4200 Digital 4.2 V 600 V 4.2 V 600 V 300 A 420 Ohm 42 MOhm 50 Ohm 1V 30 mm 145x52x34mm 100 g Test leads, battery, carry case & instructions
Part No. WAT044073
19
CLAMP METERS DIGITAL CLAMP METER ‐ ELMA FEATURES
• Compact and handy digital clamp meter with temperature measurement. • Twin display screen allows for simultaneous electrical and temperature measurement ie measure voltage and current at the same time. • Auto‐ranging and auto power off. • Data hold function and overload protection. • 26mm max jaw opening size. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, batteries, temperature sensor, carry case and operating instructions. Measuring circuit category: Display count: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Current measurement range, AC: Min resistance measuring range: Max resistance measuring range: Min. capacitance measuring range: Max capacitance measuring range: Min frequency measurement: Max frequency measurement: Temperature range: Continuity resistor: Continuity resistor range: Diode test: Voltage measurement, DC: Voltage measurement, AC: Resistance measurement range: Dimensions: Weight:
CAT III 600V 3 3/4 digit, 3999 (x2 dual screen) 4V 600 V 400 mV 600 V 40 ... 400 A 400 Ohm 40 MOhm 500 nF 3000 µF 5 Hz 100 kHz -20 ... 300 °C 120 Ohm 0.02 ... 12 kOhm 1.6 V Yes Yes Yes 190x63x32mm 190 g
Part No. WATEL-126
20
CLAMP METERS POWERCLAMP™ CLAMP METER ‐ ELMA FEATURES
• Intelligent 'auto check' feature automatically detects and selects AC/DC voltage function etc. • Auto‐ranging and auto power off. • Dual backlight display. • With PC connection‐ can be used for data logging purposes. • Data hold function and overload protection. • 45mm max jaw opening size. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, batteries, carry case and operating instructions. • THD: 0‐999%. Measuring circuit category: Display count: Measuring range selection: Max voltage measuring range, AC: Max voltage measuring range, DC: Current measurement range, AC: Max resistance measuring range: Min frequency measurement: Max frequency measurement: Temperature range: Continuity resistor: Continuity resistor range: Voltage type: Type of current: Voltage measurement, DC: Voltage measurement, AC: Dimensions: Weight:
CAT III 600V 4 digit, 9999 Automatic 600 V 600 V 40 ... 1000 A 0.001 MOhm 5 Hz 500 kHz -50 ... 300 °C 300 Ohm 0.01 ... 3 kOhm AC/DC Alternating current Yes Yes 224x78x40mm 225 g
Part No. WATEL-155
CLAMP METER 200A OPEN JAW ‐ ELMA FEATURES
• Open jaw type clamp meter and non‐contact voltage tester in one. • True RMS. • 'VoltSense' non‐contact voltage detection measured by passing open jaw against cable. • Auto‐ranging and auto power off. • Data hold function and overload protection. • Easy to use single rotary switch for function selection. • 16mm max jaw opening size. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, batteries, carry case and operating instructions. Display count: Diode test: Voltage measurement, DC: Voltage measurement, AC: Weight:
3 1/2 digit, 1999 3V Yes Yes 280 g
Part No. WATEL-2500
21
CLAMP METERS CLAMP METER 400A AC ‐ ELMA FEATURES
• Small and handy digital clamp meter. • Auto‐ranging and auto power off. • Data hold function and overload protection. • Low battery warning. • 26mm max jaw opening size. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, batteries, carry case, sample loops and operating instructions. Measuring circuit category: Display count: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Current measurement range, AC: Min resistance measuring range: Max resistance measuring range: Min. capacitance measuring range: Max capacitance measuring range: Min frequency measurement: Max frequency measurement: Continuity resistor: Continuity resistor range: Diode test: Voltage measurement, DC: Voltage measurement, AC: Resistance measurement range: Dimensions: Weight:
CAT III 600V 3 3/4 digit, 4000 4V 600 V 400 mV 600 V 40 ... 400 A 400 Ohm 40 MOhm 500 nF 3000 µF 5 Hz 100 kHz 120 Ohm 0.02 ... 12 kOhm 1.6 V Yes Yes Yes 190x63x32mm 190 g
Part No. WATEL-3036
22
CLAMP METERS CLAMP METER 400A AC TRUE RMS ‐ ELMA FEATURES
• Small and handy digital clamp meter with true RMS. • Auto‐ranging and auto power off. • Data hold function and overload protection. • Low battery warning. • 26mm max jaw opening size. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, batteries, carry case, sample loops and operating instructions. Measuring circuit category: Display count: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Current measurement range, AC: Min resistance measuring range: Max resistance measuring range: Min. capacitance measuring range: Max capacitance measuring range: Min frequency measurement: Max frequency measurement: Continuity resistor: Continuity resistor range: Diode test: Voltage measurement, DC: Voltage measurement, AC: Dimensions: Weight:
CAT III 600V 3 3/4 digit, 4000 4V 600 V 400 mV 600 V 40 ... 400 A 400 Ohm 40 MOhm 500 nF 3000 µF 5 Hz 100 kHz 120 Ohm 0.02 ... 12 kOhm 1.6 V Yes Yes 190x63x32mm 190 g
Part No. WATEL-3038
23
CLAMP METERS AC/DC DIGITAL CLAMP METER ‐ ELMA FEATURES
• Professional grade clamp meter suitable for troubleshooting and preventative measurements on installations. • True RMS. • Flexible and robust design with large backlight display. • Auto‐ranging and auto power off. • Data hold function and overload protection. • Easy to use single rotary switch for function selection. • 30mm max jaw opening size. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, temperature probe, batteries, carry case and operating instructions. Measuring circuit category: Display count: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Current measurement range, AC: Current measurement range, DC: Min resistance measuring range: Max resistance measuring range: Min. capacitance measuring range: Max capacitance measuring range: Min frequency measurement: Max frequency measurement: Temperature range: Continuity resistor: Continuity resistor range: Diode test: Voltage measurement, DC: Voltage measurement, AC: Resistance measurement range: Dimensions: Weight:
CAT IV 600V, CAT III 1000V 3 5/6 digit, 6000 6V 1000 V 600 mV 1000 V 60 ... 600 A 60 ... 600 A 600 Ohm 60 MOhm 40 nF 4000 µF 100 Hz 60 kHz -20 ... 760 °C 60 Ohm 0 ... 6 kOhm 2.8 V Yes Yes Yes 215x74x43mm 285 g
Part No. WATEL-9015
24
CLAMP METERS AUTO CHECK CLAMP‐ON MULTIMETER ‐ ELMA FEATURES
• Handheld digital clamp‐on meter with ruggedised body. • Intelligent 'auto check' feature automatically detects and selects AC/DC voltage function etc. • Auto‐ranging and auto power off. • Large LCD display screen. • Data hold function and overload protection. • With non‐contact voltage indication. • 45mm max jaw opening size. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, batteries, carry case and operating instructions. Measuring circuit category: Display count: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Lowest resolution, AC current: Max current measuring range, AC: Min resistance measuring range: Lowest resolution, resistance: Max resistance measuring range: Min frequency measurement: Max frequency measurement: Min. capacitance measuring range: Max capacitance measuring range: Continuity resistor: Min continuity resistor range: Max continuity resistor range: Diode test: NCV indication range: Dimensions: Weight:
CAT III 600V 3 5/6 digit, 6000 6V 600 V 6V 600 V 400A 2000 A 600 Ohm 600 Ohm 6 MOhm 10 Hz 1 kHz 100 nF 2000 µF 300 Ohm 10 Ohm 300 Ohm 1.6 V 15 ... 300 V 224x78x40mm 220 g
Part No. WATEL-BM117
25
CLAMP METERS MINI DIGITAL CLAMP METER ‐ ELMA FEATURES
• Small and handy digital clamp meter ideal for works in crowded switch boxes or cable areas etc. • Auto‐ranging and auto power off. • Data hold function and overload protection. • Easy to use single rotary switch for function selection. • 24mm max jaw opening size. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, batteries, carry case and operating instructions Measuring circuit category: Display count: Max voltage measuring range, AC: Max voltage measuring range, DC: Current measurement range, AC: Current measurement range, DC: Min resistance measuring range: Max resistance measuring range: Min frequency measurement: Max frequency measurement: Continuity resistor: Continuity resistor range: Voltage measurement, DC: Voltage measurement, AC: Dimensions: Weight:
CAT III 300V, CAT II 600V 3 3/4 digit, 3999 400 V 400 V 40 ... 200 A 40 ... 200 A 40 Ohm 0.0004 MOhm 1 Hz 100 kHz 400 Ohm 0.04 ... 4 kOhm Yes Yes 183x64x36mm 190 g
Part No. WATEL-CM01
CLAMP METER 400A AC/DC TRUE RMS MINI ‐ ELMA FEATURES
• Handheld digital meter with ruggedised body. • Intelligent 'auto check' feature automatically detects and selects AC/DC voltage function etc. • Auto‐ranging and auto power off. • Data hold function and overload protection. • True RMS. • Highly efficient fuses and handy backlight for dim areas. • With non‐contact voltage indication. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, rubber cover, batteries, bag and operating instructions. Measuring circuit category: Display count: Current measurement range, AC: Current measurement range, DC: Min frequency measurement: Max frequency measurement: Dimensions: Weight:
CAT III 300V, CAT II 600V 3 3/4 digit, 3999 4 ... 400 A 40 ... 400 A 10 Hz 100 kHz 180x50x29mm 200 g
Part No. WATEL-CM07
26
CLAMP METERS DIGITAL CLAMP‐ON METER ‐ ELMA FEATURES
• Quick and easy to use clamp‐on meter. • Auto‐ranging and auto power off. • Data hold function and overload protection. • Easy to use single rotary switch for function selection. • 30mm max jaw opening size. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, batteries, carry case and operating instructions. Measuring circuit category: Display count: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Current measurement range, AC: Current measurement range, DC: Min resistance measuring range: Max resistance measuring range: Continuity resistor: Voltage measurement, DC: Voltage measurement, AC: Dimensions: Weight:
CAT III 600V 3 3/4 digit, 3999 400 mV 600 V 400 mV 600 V 40 ... 400 A 40 ... 400 A 400 Ohm 40 MOhm 40 Ohm Yes Yes 195x64x30mm 240 g
Part No. WATEL-TM13E
TEST LEADS SET FOR MULTIMETERS AND CLAMP METERS ‐ WATTMASTER
FEATURES
• Test lead set for Wattmaster WATDMM and WATDCM range of meters. Type of accessory:
Testlead
Part No. WATTLS
27
INSULATION TESTERS ANALOGUE INSULATION TESTER ‐ WATTMASTER FEATURES
• Solid state circuitry and automatic circuit discharge. • Colour coded analogue scale with three megohm voltages. • Fuse protected. • Portable and self‐contained insulation tester. • Battery check feature. • Live circuit indication. • Locates intermittent shorts defective electrical connections and insulation breakdowns due to temperature moisture abrasion and corrosion. Indication: Insulation resistance measuring range: Accuracy class meter: Nominal test voltage 250 V: Nominal test voltage 500 V: Nominal test voltage 1000 V: Dimensions: Weight: Inclusion:
Analogue 50 ... 200 MOhm +/-5% of indicated value Yes Yes Yes 170x210x90mm 1000 g Test leads, power cable, hard case, batteries & instructions
Part No. WATIRT2
ANALOGUE INSULATION RESISTANCE TESTER ‐ WATTMASTER FEATURES
• Expanded insulation and continuity scales for easy reading. • Live circuit indication. • IEC 1010‐1. • Robust style and dual purpose holding case. • Fuse protected and battery check facility. • Incorporates front panel ohms zero adjust. Measuring circuit category: Indication: Insulation resistance measuring range: Accuracy class meter: Continuity resistor: Nominal test voltage 250 V: Nominal test voltage 500 V: Nominal test voltage 1000 V: Dimensions: Weight: Inclusion:
CAT III 600V Analogue 100 ... 400 MOhm +/-5% of indicated value 20 Ohm Yes Yes Yes 170x210x90mm 1000 g Test leads, fuse, shoulder strap, batteries & instructions
Part No. WATAIT2
28
INSULATION TESTERS ANALOGUE INSULATION TESTER ‐ WATTMASTER FEATURES
• Solid state circuitry and automatic circuit discharge. • Colour coded analogue scale with three megohm voltages. • Fuse protected. • Battery check feature. • Portable. • IEC 364‐6‐61. • Backlight for dimly lit areas. Indication: Insulation resistance measuring range: Accuracy class meter: Nominal test voltage 250 V: Nominal test voltage 500 V: Nominal test voltage 1000 V: Dimensions: Weight: Inclusion:
Analogue 100 ... 400 MOhm +/-5% of indicated value Yes Yes Yes 170x115x85mm 1000 g Test leads, hard case, carry strap, batteries & instructions
Part No. WATAIT3
ANALOGUE INSULATION TESTER WITH RECHARGABLE BATTERY ‐ ELMA FEATURES
• Easy to use insulation tester allows for direct voltage measurement at the connection. • Discharges the cable capacity/risidual voltage in seconds. • Low battery indication and data hold function. • With built‐in moving coil system and non‐contact voltage indication. • Easy to use single rotary switch for function selection. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, power cord, 7. • 2V rechargable battery, carry case and operating instructions. Measuring circuit category: NCV indication range: Voltage type: Data hold: Dimensions: Weight:
CAT III 600V 0 ... 600 V AC Yes 156x110x59mm 590 g
Part No. WATEL-DVM1002
29
INSULATION TESTERS ANALOGUE INSULATION TESTER WITH 9V BATTERY ‐ ELMA FEATURES
• Easy to use insulation tester allows for direct voltage measurement at the connection. • Discharges the cable capacity/risidual voltage in seconds. • Low battery indication and data hold function. • With built‐in moving coil system and non‐contact voltage indication. • Easy to use single rotary switch for function selection. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, power cord, 9V battery, carry case and operating instructions. Measuring circuit category: NCV indication range: Voltage type: Dimensions: Weight:
CAT III 600V 0 ... 600 V AC 156x110x59mm 590 g
Part No. WATEL-DVM1002B
30
INSULATION TESTERS 2‐IN‐1 INSULATION TESTER & MULTIMETER ‐ ELMA FEATURES
• 2‐in‐1 insulation tester and multimeter. • Large backlight display allows for all measurements to be viewed at the same time. • Low battery indication and data hold function. • Auto‐ranging and auto power off. • True RMS. • Store and recall button allows you to store values and recall them later. • With PC connection ‐ can be used for data logging purposes. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, batteries, USB cable, software, carry case and operating instructions. • Protection class: IP67 (dust‐tight/liquid‐tight) Measuring circuit category: Display count: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Lowest resolution, AC current: Max current measuring range, AC: Lowest resolution, DC current: Max current measuring range, DC: Lowest resolution, resistance: Max resistance measuring range: Min frequency measurement: Max frequency measurement: Min. capacitance measuring range: Max capacitance measuring range: Temperature range: Continuity resistor: Min continuity resistor range: Max continuity resistor range: Diode test: Frequency measurement: Dimensions: Weight:
CAT III 1000V, CAT IV 600V 10 digit, 40000 400 mV 1000 V 400 mV 1000 V 400 µA 10 A 400 µA 10 A 400 Ohm 40 MOhm 40 Hz 100 MHz 40 nF 40 mF -50 ... 1000 °C 400 Ohm 35 Ohm 400 Ohm 2.8 V Yes 220x97x61mm 630 g
Part No. WATEL-5800
31
INSULATION TESTERS INSULATION TESTER WITH MULTIMETER ‐ ELMA FEATURES
• 2‐in‐1 multimeter and insulation tester. • Handheld digital meter with ruggedised body. • Low battery indication. • Auto‐ranging and auto power off. • Easy to read illuminated display screen. • Data hold function and overload protection. • Automatic discharge of capacitive voltage. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, rubber cover, batteries, carry case and operating instructions. Measuring circuit category: Max voltage measuring range, AC: Max voltage measuring range, DC: Min resistance measuring range: Lowest resolution, resistance: Max resistance measuring range: Min continuity resistor range: Max continuity resistor range: Insulation resistance measuring range: Data hold: Dimensions: Weight:
CAT III 1000V, CAT IV 600V 750 V 1000 V 0 Ohm 40 Ohm 0.0004 MOhm 40 Ohm 400 Ohm 4 ... 4000 MOhm Yes 200x92x50mm 700 g
Part No. WATEL-DT5500A
DIGITAL RCD TESTER ‐ ELMA FEATURES
• Compact RCD tester with multi‐colour graphic display ensures excellent legibility. • Built‐in LED light illuminates objects in dim areas. • Measures trip out time, trip out current and contact voltage. • Low battery indication and blown fuse indication. • Auto power off and overload protection. • With non‐contact voltage indication. • When not in use instruments body and test tips slide into one making it more compact. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, pouch, calibration certificate and operating instructions Testing device for loop resistance: Measuring circuit category: Weight: Dimensions: NCV indication range: Current measurement range, AC: Lowest resolution, AC voltage: Max voltage measuring range, AC: Fault trip time: Loop impedance range: Degree of protection IP:
Yes CAT III 300V 360 g 260x70x40mm 0 ... 100 10 ... 500 mA 190 V 260 V 500 ms 0 ... 2000 Ohm IP43
Part No. WATEL-DRCD
32
VOLTAGE TESTERS COMPACT VOLTAGE TESTER ‐ THEO BENNING FEATURES
• Two‐pole voltage tester with visual display. • Designed to test voltages of 12‐400V AC and 12‐750V DC. • Voltage tester with load connection. • Data hold function. • On the spot exact illumination dimmer test points. • IEC/EN 61243‐3 DIN VDE 0682‐401. Measuring circuit category: Voltage indication: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Max continuity resistor range: Degree of protection IP: Polarity test indication: Load connection: Data hold: Type of test: Dimensions: Weight: Inclusion:
CAT IV 500V LED 12 V 400 V 12 V 750 V 90 kOhm IP64 LED I§ < 200 mA (750V DC) Yes 2-pole 250x60x25mm 160 g Battery & instructions
Part No. WAT050251
EXPERT VOLTAGE TESTER ‐ THEO BENNING FEATURES
• Two‐pole voltage tester with visual display. • Designed to test voltages of 12‐400V AC and 12‐750V DC. • Voltage and continuity tester with load connection phase sequence indication and switching load. • Data hold function. • On the spot exact illumination dimmer test points. • IEC/EN 61243‐3 DIN VDE 0682‐401. • Vibrating alarm for safe voltage detection. Measuring circuit category: Voltage indication: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Continuity resistor: Degree of protection IP: Polarity test indication: Phase sequence indication: Single pole phase test indication: Load connection: Data hold: Type of test: Dimensions: Weight: Inclusion:
CAT IV 500V LED/LCD 12 V 400 V 12 V 750 V 1.08 MOhm IP64 LED LCD LCD I§ < 200 mA (750V DC) Yes 2-pole 250x60x25mm 200 g Battery & instructions
Part No. WAT050253
33
VOLTAGE TESTERS DIGITAL PLUS VOLTAGE TESTER ‐ THEO BENNING FEATURES
• Two‐pole voltage tester with visual display. • Designed to test voltages of 5‐500V AC and 1.5‐750V DC. • Voltage and continuity tester with load connection phase sequence indication and switching load. • Data hold function. • On the spot exact illumination dimmer test points. • IEC/EN 61243‐3 DIN VDE 0682‐401. • Vibrating alarm for safe voltage detection. Measuring circuit category: Display count: Voltage indication: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Max frequency measurement: Degree of protection IP: Polarity test indication: Phase sequence indication: Single pole phase test indication: Load connection: Data hold: Type of test: Dimensions: Weight: Inclusion:
CAT IV 500V 3 digit LCD 5V 500 V 1.5 V 750 V 150 Hz IP64 LCD LCD LCD I§ < 200 mA (750V DC) Yes 2-pole 250x60x25mm 200 g Battery & instructions
Part No. WAT050255
34
VOLTAGE TESTERS ELECTRICAL VOLTAGE TESTER ‐ WATTMASTER FEATURES
• Two‐pole voltage tester with visual display. • Designed to test voltages of 12‐400V AC and 12‐690V DC. • Voltage and continuity tester with load connection phase sequence indication low impedance and rotary field indication. • Handy backlight for dim areas. • Double moulded plastic housing. • IEC/EN 61243‐3. Measuring circuit category: Voltage indication: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Continuity resistor limit: Degree of protection IP: Polarity test indication: Phase sequence indication: Single pole phase test indication: Load connection: Type of test: Dimensions: Weight: Inclusion:
CAT III 690V LED 12 V 400 V 12 V 690 V < 400 kOhm IP64 LED LED LED I§ < 0.2A 2-pole 240x78x40mm 237 g Battery & instructions
Part No. WATQP-2286
AC/DC VOLTAGE TESTER ‐ ELMA FEATURES
• Single pole voltage tester with visual display designed to test voltages of 12‐690V AC/DC. • Compact, lightweight and easy to use. • Test pen attachment with 19mm spacing fits directly into wall socket and allows one‐handed operation. • Clear indication with LEDs. • Ergonomic and robust design. • Probe tip protection and automatic AC/DC detection. • Complies with IEC 61010‐1 specifications. • Supplied with batteries and operating instructions. Measuring circuit category: Voltage indication: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Frequency range: Degree of protection IP: Polarity test indication: Dimensions: Weight:
CAT III 690V LED 12 V 690 V 12 V 690 V 0 ... 65 Hz IP54 LED 165x20x16mm 70 g
Part No. WATEL-1000A
35
VOLTAGE TESTERS VOLTAGE TESTER 690V AC/DC CAT IV 300V ‐ ELMA FEATURES
• Single pole voltage tester with visual display designed to test voltages of 12‐690V AC/DC. • Compact, lightweight and easy to use. • Voltage and continuity tester with load connection, phase sequence (single phase) indication and switching load. • Data hold function and internal basic load (also for tripping the RCD). • Ergonomic and robust design. • Probe tip protection and automatic AC/DC detection. • Complies with IEC 61010‐1 specifications. • Supplied with batteries and operating instructions. Measuring circuit category: Voltage indication: Lowest resolution, AC voltage: Max voltage measuring range, AC: Lowest resolution, DC voltage: Max voltage measuring range, DC: Continuity resistor range: Polarity test indication: Phase sequence indication: Single pole phase test indication: Single pole phase indication: Dimensions: Weight:
CAT III 600V, CAT IV 300V LED 12 V 690 V 12 V 690 V 0 ... 200 kOhm LED LED LED Yes 205x67x27mm 130 g
Part No. WATEL-1500B
TEST SCREWDRIVERS/VOLTAGE TESTERS ‐ WITTE
FEATURES
• Screwdriver voltage testers. • With metal clip (except WAT669C) for added convenienve. • Fully functional voltage tester. Voltage testing functionality:
Length 115 mm 140 mm 190 mm 153 mm
36
Yes
Voltage measurement range 220 ... 250 V 220 ... 250 V 220 ... 250 V 150 ... 250 V
Part No. WAT610C WAT630A WAT669C WAT24090
OTHER TESTERS VS3 TRACKER/TROUBLESHOOTER ‐ SAGAB
FEATURES
• Designed for fault tracing and fuse detection in 230V single phase applications during maintenace and repair. • Tests outlet configuration phase connections fuse connections connection checks and RCD tests. • Data hold function. • Auto power off. • Low battery indication. • Handy backlight for dim areas.
Part No. WATVS3
POWER POINT AND EARTH LEAKAGE TESTER ‐ WATTMASTER FEATURES
• Checks most types of power points for correct wiring and whether the earth leakage circuit breaker trips from each power point. • Displays the following faults: no earth/neutral/active connected active and neutral reversed and active and earth reversed. • For indoor use only. • AS/NZS 3100. • 10mA/15mA/30mA/100mA earth leakage circuit breaker trips settings. Indication: Number of measuring ranges: Printer connection: Dimensions: Inclusion: Weight: Current supply: Testing device for no earth connection: Testing device for no neutral connection: Testing device for no active connection: Testing device for active and neutral reversed: Testing device for active and earth reversed: Standards compliance:
Analogue 4 No 65x90x32mm 10A moulded plug & instructions 250 g Mains Yes Yes Yes Yes Yes AS/NSZ 3100
Part No. WATQP-2000
37
OTHER TESTERS CABLE TRACER ‐ WATTMASTER
FEATURES
• Instrument to identify and trace cables. • Amplifier probe and tone generator kitA 3‐position toggle switch controls the modes of operation. • A tone selector switch is provided for choosing either single solid tone or dual alternating tone. • Volume control for increased sensitivity and adjustable to suit work environment. • Works with any tone generator to identify wires. • Recessed ON/OFF button prevents battery drain.
Part No. WATFSET
CIRCUIT BREAKER IDENTIFIER & FAULT FINDER ‐ WATTMASTER FEATURES
• Circuit breaker identifier and earth fault finder Circuit breaker identification: Earth fault identification: Lowest resolution, AC voltage: Max voltage measuring range, AC: Transmitter/receiver frequency: Type of indication: Auto off timing: On/off button: Analogue bargraph display: Low battery indication: Transmitter dimensions: Receiver dimensions: Transmitter weight: Receiver weight:
Yes Yes 110 V 240 V 10 kHz LED/acoustic Approx 1 minute Yes Yes Yes 60x50x30mm 200x50x40mm 134 g 112 g
Part No. WATCBI-T188
38
OTHER TESTERS CIRCUIT BREAKER IDENTIFIER 220‐240VAC ‐ WATTMASTER
FEATURES
• Ideal tool for both automated office environments where disruption of power is not practical as well as in residential applications. • Quickly identifies and locates 220‐240VAC circuit breakers and fuses. • Audible tone generated when matching breaker is located. • It is an easy way to identify location of circuit breaker on the circuit breaker panel box which is connected to a specific outlet.
Part No. WATCBI-T191
LUX & FC LIGHT METER ‐ WATTMASTER FEATURES
• Accurately displays light level in terms of footcandles (fc) or lux over wide ranges. • Low battery indication. • Data hold function and auto power off. • Pocket sized. • Lightweight. • Includes an integrated stand. Indication: Measuring range: Display count: Dimensions: Data hold: Low battery indication: Inclusion: Weight: Blueway energy efficient:
Digital 200 ... 50000 lx 3 1/2 digit, 1999 188x64x25mm Yes Yes Carry case & instructions 160 g Energy saving product
Part No. WATQM-1587
39
OTHER TESTERS LIGHT METER 200LUX ‐ ELMA FEATURES
• Ideal for measuring a wide range of light sources eg emergency lighting and outdoor measurement in sunshine. • Large display screen. • Data hold and overload protection. • Compact, lightweight and easy to handle. • Auto power off. • High accuracy and rapid response. • Supplied with sensor, batteries, carry case and operating instructions. Measuring range: Display count: Dimensions: Data hold: Weight:
40 ... 400000 lx 3 3/4 digit, 3999 135x60x27mm Yes 250 g
Part No. WATEL-1335
INFRARED THERMO W/DOUBLE LASER 600DEG ‐ ELMA
FEATURES
• Store and recall button allows you to store values and recall them later. • With PC connection‐ can be used for data logging purposes. • Complies with IEC 61010‐1 specifications. • Supplied with test leads, batteries, USB cable, software, carry case and operating instructions. • Protection class: IP67 (dust‐tight/liquid‐tight). • Note: not recommended for measuring shiny or polished surfaces, stainless steel, aluminium etc. Measuring range: Measurement of differential temperature: Display count:
-50 ... 600 °C Yes 3 1/2 digit, 1999
Part No. WATEL-610A
40
OTHER TESTERS INFRARED THERMO W/DOUBLE LASER 1000DEG ‐ ELMA
FEATURES
• Rapid detection and dual laser sighting ie two infrared sensors. • Precise non‐contact measurements ideal for applications such as refrigerator/freezer testing, moving machine parts and electrical components, safety and fire inspections etc. • Celsius/Farenheit selection button. • Backlight LCD display. • Handy and convenient ergonomic pistol handle grip design. • Supplied with battery, carry case and operating instructions. Measuring range: Display count: Weight:
-50 ... 1000 °C 3 1/2 digit, 1999 160 g
Part No. WATEL-611B
WIRELESS ENERGY CONTROL MONITOR ‐ WATTMASTER
FEATURES
• Measures electricity consumption of single or several appliances over days weeks months and years. • Quick and easy to install. • Displays current time and temperature. • Allows you to monitor control and save electricity. • Spare sensor available: WATMS‐6156. Type of accessory:
Monitor kit
Part No. WATMS-6155
41
OTHER TESTERS TACHOMETER PHOTO/CONTACT ‐ ELMA FEATURES
• Combination photo and contact tachometer measures revolutions (via light and reflection), mechanical RPM (via measuring tip) and speed (via measuring wheel). • Memory button for remembering highest, lowest and last values. • LCD display screen. • Auto‐ranging and data hold function. • Supplied with reflective tape, test leads, carry case and operating instructions Display count: Photo contact RPM: Contact area RPM: Measuring range: Dimensions: Weight:
5 digit, 10mm 5 ... 99999 0.5 ... 19999 0.5 ... 1999.99 1/min 215x65x38mm 300 g
Part No. WATEL-DT2236
VOLT STICKS VOLT STICK ‐ SAGAB FEATURES
• Tests for the presence of AC voltage in cables wall sockets and switches without metal contact. • Pocket sized non‐contact voltage sensor with light and sound indication. • Beeping sound indicates live wire. • Fully insulated body and safety hand guard. • Still illuminates at low battery charge. Measuring circuit category: Contact less voltage detection: Voltage indication: Voltage measurement range: Lowest resolution, AC voltage: Max voltage measuring range, AC: Sensitivity specification: Material: Current supply: Dimensions: Weight:
CAT III 1000V AC Yes Glow lamp 230 ... 1000 V 230 V 1000 V Indicates within 4mm of wire carrying 230V AC Pa6, PP-COP Battery 146x18mm 40 g
Part No. WATVS
42
VOLT STICKS MAGNET FIELD INDICATOR ‐ SAGAB FEATURES
• Easy to use non‐metallic sensor test for the presence of magnetic fields. • Responds to all kinds of magnetic fields such as AC DC and permanent magnets. • For testing solenoid vaves in pneumatic and hydraulic control equipment. • Tip glows red when magnet field is detected. • Also tests relays with coils and electrically controlled solenoid valves. • Test magnet included in cap. Measuring circuit category: Voltage indication: Magnetic field indication: Sensitivity specification: Indication of direction of field rotation: Material: Current supply: Dimensions: Weight: Inclusion:
CAT III 1000V AC Glow lamp Glow lamp 300 gauss (0.3mT) Yes Pa6, PP-COP Battery 152x17mm 40 g Test magnet
Part No. WATMT702
VOLT STICK FLAT TIP ‐ SAGAB FEATURES
• Tests for the presence of AC voltage in cables wall sockets and switches without metal contact. • Pocket sized non‐contact voltage sensor with light and sound indication. • Flat tip fits into standard power point. • Beeping sound indicates live wire. • Fully insulated body and safety hand guard. • Still illuminates at low battery charge. Measuring circuit category: Contact less voltage detection: Voltage indication: Voltage measurement range: Lowest resolution, AC voltage: Max voltage measuring range, AC: Sensitivity specification: Material: Current supply: Dimensions: Weight:
CAT III 1000V AC Yes Glow lamp 230 ... 1000 V 230 V 1000 V Indicates within 4mm of wire carrying 230V AC Pa6, PP-COP Battery 146x18mm 40 g
Part No. WATVSFT
43
VOLT STICKS VOLT STICK PRO ‐ SAGAB FEATURES
• Tests for the presence of AC voltage in cables wall sockets and switches without metal contact. • Unique fork tip glows red when voltage is detected eliminating the risk of false indication. • Differentiates between live and neutral in a 1‐to‐3 phase installation. • arthed outlets with anti‐tamper can be check with the supplied adaptor found in cap. • Used to check cicuit breaker functionality and locate breaks in insulated cables. • Used to detect live cables in junction boxes and equipment cabinets. Measuring circuit category: Contact less voltage detection: Voltage indication: Voltage measurement range: Lowest resolution, AC voltage: Max voltage measuring range, AC: Sensitivity specification: Material: Current supply: Dimensions: Weight:
CAT III 1000V AC Yes Glow lamp 12 ... 600 V 12 V 600 V Indicates from 12V AC in the forked tip Pa6, PP-COP Battery 146x22mm 40 g
Part No. WATVSPRO
VOLT STICK PRO 230 ‐ SAGAB FEATURES
• Unique fork tip gives unsurpassed sensitivity and reduces the risk of false identification. • Live cables can be easily detected in equipment enclosures and fuse boxes. • Extremely safe when measuring in junction boxes. • Tips glows red when voltage is detected. • Adaptor for measuring larger objects is included. • Fully insulated for safe use. Measuring circuit category: Contact less voltage detection: Voltage indication: Voltage measurement range: Lowest resolution, AC voltage: Max voltage measuring range, AC: Sensitivity specification: Material: Current supply: Dimensions: Weight:
CAT III 1000V AC Yes Glow lamp 230 ... 1000 V 230 V 1000 V Indicates within 4mm of wire carrying 230V AC Pa6, PP-COP Battery 151x18mm 50 g
Part No. WATVSP230
44
VOLT STICKS INTRINSICALLY SAFE VOLT STICK ‐ SAGAB FEATURES
• Intrinsically safe volt stick tests for the presence of AC voltage in cables wall sockets and switches without metal contact. • Pocket sized non‐contact voltage sensor with light indication. • Locates breaks in cables and detects blown fuses. • Distinguishes between live and neutral wires in both single phase and three phase supply. • Safety hand guard prevents contact with dangerous cable. • IEC Ex NEM 07.0001. Measuring circuit category: Contact less voltage detection: Voltage indication: Voltage measurement range: Lowest resolution, AC voltage: Max voltage measuring range, AC: Sensitivity specification: Material: Current supply: Dimensions: Weight:
CAT III 100V Yes Glow lamp 230 ... 1000 V 230 V 1000 V Indicates within 4mm of wire carrying 230V AC Pa6, PP-COP Battery 151x18mm 40 g
Part No. WATVS660-642
50V VOLT STICK ‐ SAGAB FEATURES
• Tests for the presence of AC voltage in cables wall sockets and switches without metal contact. • Pocket sized non‐contact voltage sensor with light indication. • Tip glows red when voltage is detected. • Fully insulated for safe use. • Safety hand guard prevents contact with dangerous cable. • IEC Ex NEM 07.0001. Measuring circuit category: Contact less voltage detection: Voltage indication: Voltage measurement range: Lowest resolution, AC voltage: Max voltage measuring range, AC: Sensitivity specification: Material: Current supply: Dimensions: Weight:
CAT III 1000V AC Yes Glow lamp 50 ... 1000 V 50 V 1000 V Indicates within 4mm of wire carrying 50V AC Pa6, PP-COP Battery 145x18mm 35 g
Part No. WATVS-LV50
45
INDEX BY PART NUMBER Part No. WAT044073 WAT044073 WAT050251 WAT050253 WAT050255 WAT115A WAT24090 WAT610C WAT630A WAT669C WATAIT2 WATAIT3 WATCBI-T188 WATCBI-T191 WATDCM1046 WATDCM1065 WATDCM2606 WATDMM9001 WATDMM904 WATEL-1000A WATEL-126 WATEL-1335
46
Page 9 19 33 33 34 5 36 36 36 36 28 29 38 39 17 18 18 8 6 35 20 40
Part No. WATEL-1500B WATEL-155 WATEL-25 WATEL-2500 WATEL-3036 WATEL-3038 WATEL-5800 WATEL-5800 WATEL-610A WATEL-611B WATEL-805 WATEL-807 WATEL-9015 WATEL-BM117 WATEL-BM257 WATEL-BM829 WATEL-CM01 WATEL-CM07 WATEL-DRCD WATEL-DT2236 WATEL-DT5500A WATEL-DT5500A
Page 36 21 7 21 22 23 31 16 40 41 10 11 24 25 12 13 26 26 32 42 32 14
Part No. WATEL-DVM1002 WATEL-DVM1002B WATEL-TM13E WATFSET WATIRT2 WATMS-6155 WATMT702 WATQM-1020 WATQM-1500 WATQM-1587 WATQP-2000 WATQP-2286 WATTLS WATTLS WATVS WATVS3 WATVS660-642 WATVSFT WATVS-LV50 WATVSP230 WATVSPRO
Page 29 30 27 38 28 41 43 15 14 39 37 35 27 17 42 37 45 43 45 44 44
Measurement_cover_Final.pdf 1 14/11/2012 12:41:06 PM
C
M
Y
CM
MY
CY
CMY
K
54 Lakewood Boulevard, Carrum Downs Victoria, 3201 AUSTRALIA T: +613 9775 1186
F: +613 9775 1187
Customer Service Centre T: 1300 300 747
F: 1300 300 074
www.wattmaster.com.au
TEST AND MEASUREMENT