Track three-phase ceiling-mounted/pendant
Installation diagram
Capacity / Weight The track can support a load of 2 kg per 200 mm, with a maximum distance between fixing points of 1000 mm. For a load of 5 kg per 200 mm, the fixing point distance must be shortened to 500 mm.
Three-phase track, 16 A Class 1, conforms to current EN 60570 standards. Made in extruded aluminium, this houses the wires enclosed in two PVC extrusions with high-resistance insulating properties.
Assembly diagram demonstration (as seen from above) 35065.__ 35070.__
35068.__
35067.__
35073.__
35077.__ 35072.__
35071.__
35080.__
224
35066.__
35075.__
Connection to the single-phase 230/250 V electricity mains supply. This allows an overall charge of 16 A, which corresponds to 3680/4000 Watts divided between three circuits. Connection to the three-phase 230/400 V electricity mains supply. This allows an overall charge of 16 A, which corresponds to 11040 Watts divided between three circuits (3x3680 Watts).
three-phase ceiling-mounted/pendant Track
21
27 Length [mm]
Code
35061.__ 35062.__ 35063.__ 35064.__
1000 2000 3000 4000
33
11
36
11
82
accessories
27
80
right-hand control gear code 35070.__ left-hand control gear code 35071.__
linear joint with contacts code 35075.11 code 35075.27 linear joint without contacts code 35076.11 code 35076.27
central control gear and linear joint code 35065.__
ceiling attachment kit code 35081.00
right-hand T-type joint code 35072.__ left-hand T-type joint code 35073.__
end cap code 35080.__
X-type joint code 35077.__
track cover L=1000 mm code 35079.11 code 35079.27
internal L-type coupling code 35067.__ external L-type coupling code 35068.__
steel suspension wire kit H=2000 mm, L=60 mm code 35074.11 code 35074.27
0
12
12
0
12
0
80
60
80
flexible joint code 35066.__
12
0
12
0
steel suspension wire kit H=2000 mm, L=120 mm code 35069.11 code 35069.27
wire strip L=120 mm code 35078.00
225
Track three-phase recessed
Installation diagram
Capacity / Weight The track can support a load of 2 kg per 200 mm, with a maximum distance between fixing points of 1000 mm. For a load of 5 kg per 200 mm, the fixing point distance must be shortened to 500 mm.
Three-phase track, 16 A Class 1, conforms to current EN 60570 standards. Made in extruded aluminium, this houses the wires enclosed in two PVC extrusions with high-resistance insulating properties.
Assembly diagram demonstration (as seen from above) 35065.__ 35047.__ 35070.__
35068.__
35045.__ 35067.__
35073.__
35077.__ 35072.__
35071.__ 35046.__
35080.__
226
35066.__
35075.__
Connection to the single-phase 230/250 V electricity mains supply. This allows an overall charge of 16 A, which corresponds to 3680/4000 Watts divided between three circuits. Connection to the three-phase 230/400 V electricity mains supply. This allows an overall charge of 16 A, which corresponds to 11040 Watts divided between three circuits (3x3680 Watts).
three-phase recessed Track
21
27 Length [mm]
Code
35041.__ 35042.__ 35043.__ 35044.__
1000 2000 3000 4000
33
11
53
Plasterboard cut 37 mm
11
82
accessories
27
linear joint with contacts code 35075.11 code 35075.27 linear joint without contacts code 35076.11 code 35076.27
right-hand control gear code 35045.__ left-hand control gear code 35046.__
80
0
80
12
internal L-type joint code 35067.__ external L-type joint code 35068.__
central control gear and linear joint code 35047.__
80
80
right-hand control gear code 35070.__ left-hand control gear code 35071.__
flexible joint code 35066.__
central control gear and linear joint code 35065.__
end cap code 35080.__
right-hand T-type joint code 35072.__ left-hand T-type joint code 35073.__
ceiling attachment kit code 35048.00
X-type joint code 35077.__
track cover L=1000 mm code 35079.11 code 35079.27
0
12
12
0
12
0
227