Lux 350/400 - Twin programme
for a wider range, see catalogue
design: Luca Trazzi
Outdoor spotlights for the illumination of buildings, car parks, streets and public spaces. It is available in two sizes: Ă˜ 350 mm and Ă˜ 400 mm with five different beams, so as to satisfy the most varied technical lighting requirements.
Lux 350
136
page 142
Lux 400
page 146
Lux 350/400 - Twin
Twin support system for Lux 350 and Lux 400 installation, consisting of cast aluminium fixing brackets, steel arm and tie rod; it is set up for use with the most common pole diameter sizes.
arm Twin 1
page 148
arm Twin 2
page 150
arm Twin 3
page 152
137
Lux 350 - Twin programme
Types of optic for Lux 350
MH 150 W G12 L
Ø
Emed
3.00
0.36
33659
Super spot optic Suitable for the illumination of architectural details from a distance: spires, statues and capitals.
MH 150 W G12 L
Ø
Emed
3.00
0.94
4550
Spot optic Suitable for the illumination of large architectural details: monuments, fountains and gardens.
MH 150 W G12 L
Ø
Emed
3.00
2.24
911
Flood optic Suitable for the uniform illumination of large surfaces: facades, large green spaces and large architectural constructions.
MH 150 W RX7s-24 H
B
I
Lm
Uo
UL
TI
7.50
6.00
24.00
1.3
0.4
0.5
3
Street optic The street optic has been designed so as to concentrate most of the light it produces onto the road surface below, meaning that fewer installations are required and thus limiting maintenance and electricity costs. The optic system can be used to achieve high and uniform luminance on the road while limiting glare. Illumination class: ME3c
138
programme Lux 400 - Twin
Types of optic for Lux 400
MH-T 250 W E40 L
Ă˜
Emed
3.00
1.05
5068
Spot optic Suitable for the illumination of large architectural details: monuments, fountains and gardens.
MH-T 250 W E40 L
Ă˜
Emed
3.00
1.95
1314
Flood optic Suitable for the uniform illumination of large surfaces: facades, large green spaces and large architectural constructions.
Combined pole installation Lux 350 and 400 spotlights can be pole-mounted, and may be applied in various size, wattage and optic combinations.
L = distance of the spotlight from the wall [m] Ă˜ = diameter of the illuminated surface [m] Emed = average illuminance [lux] Road surface C2, q0=0.070 H= fixture height [m] B = road width [m] I= distance between poles [m] Lm= average maintained luminance [cd/m2] Uo= general uniformity of luminance UL= longitudinal uniformity of luminance TI= physiological glare index [%] Em= average illuminance [lx] Emin= minimum illuminance [lx]
139
Lux 350/400 - Twin programme
Twin 1 spotlight rotation
Twin 2 spotlight rotation
Twin 3 spotlight rotation
360째 360째 360째
360째
10,000 8,000 6,000 4,000
140
spotlight Lux 350/400 design: Luca Trazzi
Lux 400
Lux 350
water drainage system
easy access to the lamp compartment
Body Die-cast aluminium body and closure glass support ring. The tempered safety glass is fixed to the ring, and the steel spotlight fixing bracket is bolted to the body using two stainless steel screws. Light sources Double-cap and single-cap metal halide lamps. Single-cap tubular high-pressure sodium lamps. Emissions Lux 350: super spot optic, spot optic, flood optic, street optic and asymmetrical optic. Lux 400: spot optic and flood optic.
vertical aim positioning (240째)
heat dissipator
Power supply Phased electromagnetic ballasts with thermal cutout. Timed ignitors with digital deactivation prolong the life of the components by avoiding unnecessary discharge lamp ignition attempts when they have been exhausted. Accessories Wall/floor-mounting bracket, stake, ring for elliptical projection glass, coloured filters, protective grille, ring-shaped baffle and visor. Colours Embossed-effect grey, anthracite grey or corten finishing.
141
Lux 350 spotlight
32 W [kg]
Code
E27 G12 G12
10.5 11.0 12.0
75445.__ 75430.__ 75433.__
IP65 0.083 m2 integrated electromagnetic control gear
MH-T E27
MH G12
70W
150W
Light source
Wattage
Socket
W [kg]
Code
MH-T SHP-T MH MH
70 W 70 W 150 W 250 W
E27 E27 G12 G12
10.5 10.5 11.0 12.0
75446.__ 75443.__ 75431.__ 75434.__
IP65 0.083 m2 integrated electromagnetic control gear spot optic MH-T E27
SHP-T E27
70W
70W
MH G12
MH G12
150W
250W
Light source
Wattage
Socket
W [kg]
Code
MH-T SHP-T MH MH
70 W 70 W 150 W 250 W
E27 E27 G12 G12
10.5 10.5 11.0 12.0
75447.__ 75444.__ 75432.__ 75435.__
IP65 0.083 m2 integrated electromagnetic control gear flood optic MH-T E27
SHP-T E27
70W
70W
MH G12
150W
142
357
56
super spot optic
79
Ø 350
Socket
70 W 150 W 250 W
Ø 166
Wattage
MH-T MH MH
215
Light source
86
spotlight Lux 350
79 Wattage
Socket
W [kg]
Code
MH / SHP MH / SHP
70 W 150 W
RX7s RX7s-24
10.5 11.0
75450.__ 75451.__
IP65 0.083 m2 integrated electromagnetic control gear
357
Ø 350
Light source
Ø 166
86
215
32
asymmetrical optic 56
MH RX7s
SHP RX7s
70W
70W
MH RX7s-24
SHP RX7s-24
150W
150W
Light source
Wattage
Socket
W [kg]
Code
MH / SHP MH / SHP
70 W 150 W
RX7s RX7s-24
10.5 11.0
75448.__ 75449.__
IP65 0.083 m2 integrated electromagnetic control gear road optic
MH RX7s
SHP RX7s
70W
70W
MH RX7s-24
SHP RX7s-24
150W
150W
143
Lux 350 accessories
32
86
Ă˜ 265
glare reduction visor code 75488.__
refractor for elliptical projection code 75609.00
plate for floor and wall installation code 75489.__
ring-shaped baffle code 75485.00
spike code 75487.00
18
150
M12
filter yellow code 75606.00 green code 75607.00 blue code 75605.00 red code 75608.00
150
150
100
13
safety grille code 75486.00
144
100
353
79
Lux 350
145
Lux 400 spotlight
32 W [kg]
Code
E40 E40 E40 E40
13.5 14.0 14.0 15.0
75461.__ 75463.__ 75457.__ 75465.__
416
Ø387
Socket
100 W 150 W 150 W 250 W
Ø188
Wattage
MH-T / SHP-T MH-T SHP-T MH-T
79
249
Light source
86
IP65 0.149 m2 integrated electromagnetic control gear spot optic
60
MH-T E40
SHP-T E40
150W
150W
MH-T E40
250W
Light source
Wattage
Socket
W [kg]
Code
MH-T / SHP-T MH-T SHP-T MH-T
100 W 150 W 150 W 250 W
E40 E40 E40 E40
13.5 14.1 15.0 15.0
75462.__ 75464.__ 75458.__ 75466.__
IP65 0.149 m2 integrated electromagnetic control gear flood optic MH-T E40
SHP-T E40
150W
150W
MH-T E40
250W
Wattage
Socket
W [kg]
Code
MH-T
400 W
E40
16.0
75467.__
461
Ø 188
IP65 0.158 m2 integrated electromagnetic control gear
OSRAM HQI-T 400/N/SI C.L. 3.25 A lamp. Martini code 4.96095.57 Colour variations may occur in vertical operating position with attachment facing downwards.
265
flood optic
Ø387
Light source
60
MH-T E40
400W
146
accessories Lux 400
79 Ă˜316
glare reduction visor code 75493.__
refractor for elliptical projection code 75614.00
plate for floor and wall installation code 75489.__
safety grille code 75491.00
spike code 75487.00
168
12
150
yellow filter code 75611.00 green filter code 75612.00 blue filter code 75610.00 red filter code 75613.00
M12
86
13
150
100
32
100
353
147
Twin 1 arm
spotlight aim adjustment
tie rod attachment
148
rotation options
pole-arm attachment
arm Twin 1
32
86
79 single joint
Ø 60 Ø 89 Ø 102 Ø 120 Ø 142 Ø 171
H = 155 H = 155 H = 155 H = 155 H = 180 H = 180
Ø
78000.__ 78004.__ 78008.__ 78012.__ 78016.__ 78020.__
H
1150
double joint
Ø 60 Ø 89 Ø 102 Ø 120 Ø 142 Ø 171
1280
single Twin 1 arm code 78042.__
1145
860
650
H = 155 H = 155 H = 155 H = 155 H = 180 H = 180
Ø
78001.__ 78005.__ 78009.__ 78013.__ 78017.__ 78021.__
H
2300
1280
double Twin 1 arm code 78045.__
1145
860
1300
guide to ordering
+
fixture
+
pole
page 206
+
joint (1-piece pack)
arm
149
Twin 2 arm
tie rod attachment
pole-arm attachment
spotlight aim adjustment
150
rotation options
arm Twin 2
32
86
79 single joint
Ø 60 Ø 89 Ø 102 Ø 120 Ø 142 Ø 171
H = 155 H = 155 H = 155 H = 155 H = 180 H = 180
Ø
78000.__ 78004.__ 78008.__ 78012.__ 78016.__ 78020.__
H
double joint
Ø 60 Ø 89 Ø 102 Ø 120 Ø 142 Ø 171
1320
single Twin 2 arm code 78041.__
1145
940
H = 155 H = 155 H = 155 H = 155 H = 180 H = 180
Ø
78001.__ 78005.__ 78009.__ 78013.__ 78017.__ 78021.__
H
1145
1880
1320
double Twin 2 arm code 78044.__
guide to ordering
+
fixture
+
pole
page 206
+
joint (1-piece pack)
arm
151
Twin 3 arm
tie rod attachment
pole-arm attachment
spotlight aim adjustment
152
rotation options
arm Twin 3
32
86
79 single joint
Ø 60 Ø 89 Ø 102 Ø 120 Ø 142 Ø 171
H = 155 H = 155 H = 155 H = 155 H = 180 H = 180
Ø
78000.__ 78004.__ 78008.__ 78012.__ 78016.__ 78020.__
H
860
1145
1150
single Twin 3 arm code 78040.__
double joint
Ø 60 Ø 89 Ø 102 Ø 120 Ø 142 Ø 171
H = 155 H = 155 H = 155 H = 155 H = 180 H = 180
Ø
78001.__ 78005.__ 78009.__ 78013.__ 78017.__ 78021.__
H
1145
860
2300
double Twin 3 arm code 78043.__
guide to ordering
+
fixture
+
pole
page 206
+
joint (1-piece pack)
arm
153