Construction Document Samples

Page 1

LEX BOENKER, MLA CONSTRUCTION DOCUMENT SAMPLES 2022


1

2

4

3

5

7

6

8

9

10

LANDSCAPE NOTES 1.

EXISTING UTILITIES: LOCATE ALL UTILITIES PRIOR TO COMMENCEMENT OF WORK. CALL SUNSHINE STATE ONE CALL - SEE LOGO BELOW.

2.

PLANTING PREPARATION: REMOVE ALL CONSTRUCTION DEBRIS, LIMEROCK, GRAVEL, ROAD BEDDING, LITTER, AND OTHER ITEMS POTENTIALLY DAMAGING TO PLANT GROWTH WITHIN PROPOSED LANDSCAPE AND TURF AREAS PRIOR TO PLANTING. MAINTAIN EXISTING GRADES UNLESS OTHERWISE APPROVED BY THE OWNER'S REPRESENTATIVE. IF FILL IS REQUIRED, USE A CLEAN, SANDY LOAM WITH pH 5.5-6.5 AND EXCAVATED FROM LOCAL SOURCES AND DEEP PITS SUCH THAT IT IS FREE OF WEEDS, SEEDS, LITTER, TOXINS, AND OTHER ITEMS HARMFUL TO PLANTINGS.

J

QTY 2

BOTANICAL NAME Betula nigra `Duraheat`

COMMON NAME Duraheat River Birch

SIZE 15 gal., 8` ht. x 36" spr., 1.5" cal.

SPACING As shown

14

Cercis canadensis

Eastern Redbud

30 gal., 8` ht. x 30" sprd., 1.5" cal.

As shown

LT

4

Liriodendron tulipifera

Tulip Poplar

15 gal., 8` ht. x 36" spr., 1.5" cal.

As shown

QM

4

Quercus michauxii

Swamp Chestnut Oak

15 gal., 8` ht. x 36" spr., 1.5" cal.

As shown

4.

PLANT MATERIAL, GENERAL: ALL PLANT MATERIALS SHALL MEET 'FLORIDA NUMBER 1' REQUIREMENTS AS PER THE MOST CURRENT EDITION OF 'FLORIDA GRADES AND STANDARDS FOR NURSERY PLANTS', FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES.

PALMS SP

QTY 11

BOTANICAL NAME Sabal palmetto

COMMON NAME Cabbage Palmetto

SIZE Height as shown, 12" min. cal. at 4.5` above grade

SPACING As shown

NOTES Regenerated

5.

PROPOSED TREES: TREES PROPOSED SHALL BE A MINIMUM OF EIGHT FEET TALL.

6.

NEW TREE STAKING: IF NECESSARY TO MAINTAIN TREES PLUMB, TREES SHALL BE STAKED WITH BIODEGRADABLE STAKING MATERIALS.

SHRUBS IV

QTY 39

BOTANICAL NAME Ilex vomitoria 'Schillings Dwarf'

COMMON NAME Schillings Dwarf Yaupon Holly

SIZE 3 gal., 24" ht. x 18" sprd.

SPACING 30" o.c.

NOTES

7.

DISTURBED AREAS: PROVIDE THREE ROWS OF SOD ALONG ALL PAVEMENT. PROVIDE SOD IN DISTURBED AREAS OF SITE AND ON ANY SLOPES 4:1 OR GREATER. SEE CIVIL PLANS FOR GRASSING REQUIREMENTS FOR STORMWATER PONDS. SOD TYPE SHALL BE PER THE PLANT SCHEDULE. SOD SHALL BE SAND-GROWN, STRONGLY ROOTED, WITHOUT SYNTHETIC STABILIZING MATERIALS, FREE OF PESTS, AND CERTIFIED FREE OF NOXIOUS WEEDS BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES, DIVISION OF PLANT INDUSTRY. SEED SHALL BE CLEAN AND DRY WITH A MIN. 80% GERMINATION RATE. SEE CIVIL PLANS FOR SODDING INFORMATION FOR STORMWATER FACILITIES.

MC

92

Muhlenbergia capillaris

Pink Muhly

3 gal., 24" ht. x 18" sprd.

36" o.c.

MULCH PSW

QTY 944 sf

BOTANICAL NAME Pine Straw

COMMON NAME Pine Straw

SIZE 3" depth, when settled, free of sticks and cones

SPACING

NOTES on slopes

SOD/SEED SOD

QTY 74 sf

BOTANICAL NAME Paspalum notatum `Argentine`

COMMON NAME Argentine Bahia Grass

SIZE sod

SPACING

NOTES Sand grown and weed free

8.

MULCH: MULCH TO BE PINESTRAW, FREE OF CONES, BRANCHES, AND DEBRIS TO A DEPTH OF 3",SETTLED, AT ALL NEW PLANTINGS. AT INSTALLATION, MULCHES SHALL BE APPLIED AT A DEPTH OF AT LEAST TWO INCHES. NO VISIBLE PLASTIC SURFACE COVERS SHALL BE USED.

9.

IRRIGATION: ALL LANDSCAPED AREAS SHALL BE PROVIDED WITH AN IRRIGATION SYSTEM OR A READILY AVAILABLE WATER SUPPLY LOCATED WITHIN 100 FEET. SEE IRRIGATION PLAN.

10.

RESPONSIBILITY: DEAD OR SEVERELY DAMAGED OR DISEASED PLANT MATERIAL SHALL BE REPLACED IN ACCORDANCE WITH THE STANDARDS SPECIFIED IN CITY OF NEWBERRY CODE OF ORDINANCES CHAPTER 74 PLANNING - ARTICLE III. - TREE CITY ORDINANCE SEC. 74-69., WITHIN A TIME PERIOD APPROPRIATE TO THE GROWING SEASON OF THE SPECIES IN QUESTION, BUT NOT EXCEEDING ONE YEAR. ALL PLANTINGS SHALL BE MAINTAINED IN A HEALTHY GROWING CONDITION AT ALL TIMES.

SITE CANOPY AND UNDERSTORY TREES Required

Acres

Front / 3 canopy trees per acre Sides and Rear / 2 canopy trees per acre

6 - Understory trees

2.34

2.34

2.34

7.02

4.68

14.04

Provided

7.02

7 Canopy trees

4.68

East: 5 Canopy trees West: 5 Canopy trees Rear: 5 Canopy trees

R

North and South / Per 100/LF: 4 Canopy trees

20

0.20

46

0.46

Provided

TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. ROOTBALL SITS ON BOTTOM OF PLANTING PIT

EQUAL

2 X ROOTBALL WIDTH

East: 2 Canopy trees West: 2 Canopy trees

PHASE 2

East and West / Per 100/LF: 4 Canopy trees

44

0.71

0.44

Provided

2.84

North: 3 Canopy trees South: 3 Canopy trees

MULCH, 3" THICKNESS TYPICAL. 1" MAXIMUM OVER ROOTBALL. SOIL BERM TO OUTSIDE OF ROOTBALL.

FINISH GRADE

2 - LT 2 - SP

ELLIANOS COFFEE SHOP

FUTURE RETAIL BUILDING

10' C.T.

23 - IV

2

1 - QM

18 - MC 8 - IV EXISTING FENCE TO REMAIN

E

21-015

PROJECT NO:

1 - LT

CLIENT'S NO.:

SOD

1 - SP

1 - QM

10' C.T.

TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. 3 X ROOTBALL DIMENSION

Provided along each facade as close to building as proposed paving and site layout allows

F

1 - SP

14' C.T.

SCARIFY SIDE SLOPES

Provided

C

1 - QM

17 - MC

10' C.T.

CUT INTO GRADE AT EDGE OF BED SUCH THAT MULCH SURFACE MEETS FINISH GRADE.

SHRUBS

Row of shrubs along each facade

PHASE 1 PHASE 2

1 - SP

8 - IV

1 - SP

10' C.T.

East: 2 Canopy trees West: 2 Canopy Trees

1.76

Per Developer Agreement NO. DA-LDR 21-35. Requirement

14' C.T.

14' C.T.

MULCH, TYP.

Required

G

1 - QM

PHASE 1 PHASE 2

D

71

Mr. Eric Preston

SOD DISTURBED AREAS, TYP.

Per Developer Agreement NO. DA-LDR 21-35.

North and South / Per 100/LF: 4 Canopy trees

for

2 - SP

PLANTING DETAIL 1 TREE SCALE: N.T.S

FACADE TREES - FUTURE RETAIL BUILDING LF

14' C.T.

6 - MC

LOOSEN SIDE SLOPES OF PLANTING PIT

E

Location / Requirement

Newberry, FL

1 - LT

SOD

North: 1 Canopy tree South: 1 Canopy tree

1.84

H

25 - MC

CL

EQUAL East and West / Per 100/LF: 4 Canopy trees

ELLIANOS COFFEE SHOP

18' C.T.

SOD DISTURBED AREAS, TYP.

FINISH GRADE

0.80

I

MULCH, 3" THICKNESS TYPICAL AND ONLY 1" OVER ROOTBALL

Per Developer Agreement NO. DA-LDR 21-35.

Required

PROJECT NAME:

TOP OF ROOTBALL 1-2" ABOVE FINISH GRADE

FACADE TREES - ELLIANOS COFFEE SHOP LF

Certificate of Authorization No. LC26000575

2 - SP

3" - 6" SOIL BERM TO OUTSIDE OF ROOTBALL

Location / Requirement

J

SEAL:

14 Understory trees

14.04

W

/ D A O

6 SR 2

Site Planning

Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412

SW 246TH TER

Location / Requirement

Y BERR

W

NE T S E

NOTE: 1. ENSURE PLANTING PIT DRAINS WELL PRIOR TO INSTALLATION. 2. REMOVE TREE FROM CONTAINER OR REMOVE UPPER 1/3 OF BURLAP AND WIRE MESH FOR B&B TREES. 3. SLICE ROOTBALL VERTICALLY ON OUTSIDE EDGES OF AND AROUND ROOTBALL. 4. TREE TO BE PLUMB. STAKE TREE IF NEEDED. SUBMIT TREE STAKING DETAILS AND LAYOUT FOR APPROVAL.

Per Developer Agreement NO. DA-LDR 21-35.

F

NOTES Multi-trunk, 3 canes minimum

CC

H

G

TREES BN

PRUNING: IF TREE OR ROOT PRUNING IS REQUIRED, THESE ACTIVITIES SHALL BE PERFORMED BY AN ARBORIST CERTIFIED BY THE INTERNATIONAL SOCIETY OF ARBORICULTURE (ISA). TREE PRUNING SHALL BE DONE IN ACCORDANCE WITH THE MOST CURRENT VERSION OF THE AMERICAN NATIONAL STANDARD FOR TREE CARE OPERATIONS "TREE. SHRUB AND OTHER WOODY PLANT MAINTENANCE" (ANSI 300) AND "PRUNING. TRIMMING. REPAIRING. MAINTAINING, AND REMOVING TREES. AND CUTTING BRUSH—SAFETY REQUIREMENTS" (ANSI Z133). NO MORE THAN 25 PERCENT OF THE CROWN SHOULD BE REMOVED AT ONE TIME. ON YOUNG TREES, LIMB REMOVAL SHALL LEAVE NO MORE THAN 33 PERCENT OF THE TRUNK BARE OF BRANCHES.

3.

I

Landscape Architecture

PLANT SCHEDULE

1 - SP

2 - CC

3 - CC

20 - MC

1 - BN

ROOTBALL ON EXISTING SOIL

SITE PLAN REVIEW

ISSUED DATE:

29 APR 2022

D

MULCH, TYP.

1 - BN

ISSUED FOR:

REVISIONS:

6 - MC

SOD 3 - CC

SHRUB AND GROUNDCOVER PLANTING DETAIL

3 - CC

C

BASIN 1

SCALE: N.T.S

SILT FENCE

SEE CIVIL PLANS FOR GRASSING OF STORMWATER SWALES AND FACILITIES, TYP. SCALE:

12" OFFSET FOR GROUNDCOVERS 18" OFFSET FOR SHRUBS

ER NT CE G ON ACIN SP

B

SOD DISTURBED AREAS, TYP.

ON CENTER SPACING

3 - CC

0

BEDLINE OR PAVING EDGE

PROPOSED TREE

TRIANGULAR LAYOUT, TYPICAL, IN STRAIGHT RUNS AND AS MUCH AS POSSIBLE AROUND CURVES. ON CENTER SPACING DISTANCE SHALL BE AS INDICATED IN SCHEDULE.

A

3 1

2

3

A

LS-2

SCALE: N.T.S

4

LANDSCAPE PLAN, SCHEDULE, NOTES, DETAILS AND CALCULATIONS SHEET NUMBER:

SHRUB AND GROUNDCOVER LAYOUT DETAIL 5

6

7

8

9

10

40'

SHEET TITLE:

LEGEND

OUTSIDE ROW FOLLOWS CURVE AS SHOWN. ROWS REMAIN PARALLEL AROUND CURVE.

20'

SCALE: 1" = 20'

B

NORTH

10'


1

2

4

3

5

7

6

8

9

10

Landscape Architecture J

I

J

ON CENTER SPACING

PLANT SCHEDULE SHRUBS AG

QTY 73

BOTANICAL NAME Agapanthus africanus ` Ella Mae`

COMMON NAME Ella Mae Agapanthus

SIZE 3 gal., 16" ht. x 14" spr.

SPACING 30" o.c.

NOTES Full

DE

22

Dioon edule

Mexican Cycad

7 gal., 36" ht. x 36" sprd.

As shown

Full

NC

9

Nerium oleander 'Calypso'

Calypso Oleander

3 gal., 36" ht. x 30" sprd.

60" o.c.

OH

35

Opuntia humifusa

Prickly Pear

7 gal., 36" ht. x 24" sprd.

48" o.c.

RC

228

Rosa x `Coral Drift`

Coral Drift Rose

3 gal., 12" ht. x 18" sprd.

24" o.c.

YU

54

Yucca filamentosa 'Blue Sentry'

Adam's Needle

3 gal., 24" ht. x 24" sprd.

36" o.c.

Full

GROUND COVERS HD

QTY 168

BOTANICAL NAME Helianthus debilis

COMMON NAME Dune Sunflower

SIZE 1 gal., 12" ht. x 18" sprd.

SPACING 30" o.c.

NOTES

JB

303

Juniperus conferta `Blue Pacific`

Blue Pacific Juniper

1 gal., 6" ht. x 12" sprd.

24" o.c.

TA

311

Trachelospermum asiaticum `Tri Color`

Tri Color Asiatic Jasmine

1 gal., 6" ht. x 12" sprd.

18" o.c.

Full

SOD/SEED SOD

QTY 4,545

BOTANICAL NAME Paspalum notatum `Argentine`

COMMON NAME Bahia Grass

SIZE sod

SPACING

NOTES Sand grown and weed free

FINISH GRADE

ON CENTER SPACING

Certificate of Authorization No. LC26000575 PROJECT NAME:

I

TECH CITY ENTRY

BEDLINE OR PAVING EDGE

SCARIFY SIDE SLOPES TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. 3 X ROOTBALL DIMENSION

1

ON CENTER SPACING

Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412

OUTSIDE ROW FOLLOWS CURVE AS SHOWN. ROWS REMAIN PARALLEL AROUND CURVE.

CUT INTO GRADE AT EDGE OF BED SUCH THAT MULCH SURFACE MEETS FINISH GRADE.

H

12" OFFSET FOR GROUNDCOVERS 18" OFFSET FOR SHRUBS

MULCH, 3" THICKNESS TYPICAL. 1" MAXIMUM OVER ROOTBALL. SOIL BERM TO OUTSIDE OF ROOTBALL.

TRIANGULAR LAYOUT, TYPICAL IN STRAIGHT RUNS AND AS MUCH AS POSSIBLE AROUND CURVES. ON CENTER SPACING DISTANCE SHALL BE AS INDICATED IN SCHEDULE.

ROOTBALL ON EXISTING SOIL

SHRUB AND GROUNDCOVER PLANTING DETAIL

2

SCALE: N.T.S.

Site Planning

H

SHRUB AND GROUNDCOVER LAYOUT DETAIL

Alachua, FL

SCALE: N.T.S.

for

LANDSCAPE NOTES

86 - HD G

3 - NC

F

7 - DE 11 - OH

E

LOCATE ALL UTILITIES PRIOR TO COMMENCEMENT OF WORK. CALL SUNSHINE STATE ONE CALL - SEE LOGO.

2.

COMPLY WITH ALL STATE AND LOCAL CODES.

3.

ALL PLANT MATERIALS SHALL MEET 'FLORIDA NUMBER 1' REQUIREMENTS AS PER THE MOST CURRENT EDITION OF 'FLORIDA GRADES AND STANDARDS FOR NURSERY PLANTS', FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES.

4.

SOD SHALL BE SAND-GROWN, STRONGLY ROOTED, FREE OF WEEDS, PESTS, AND NOXIOUS SPECIES, AND NOT DORMANT. PROVIDE SOD OF A UNIFORM PAD SIZE AND OF A GROWTH SUCH AS TO BE ABLE TO GRASPED AND LIFTED WITHOUT BREAKING APART. DO NOT USE SYNTHETIC STABILIZING MATERIALS WITHIN OR BELOW SOD.

5.

SUBSTITUTIONS SHALL NOT BE ACCEPTED UNLESS OWNER'S REPRESENTATIVE APPROVES A SUBMITTAL FROM THE CONTRACTOR INCLUDING THE REASON FOR REQUESTED SUBSTITUTIONS AND A LIST OF ALL REQUESTED ALTERNATIVE MATERIALS WITH SCIENTIFIC AND COMMON NAMES, VARIETIES, SIZES, AND COST DIFFERENCE PER PLANT TYPE. SUBMITTAL SHALL BE APPROVED PRIOR TO ORDERING OF REQUESTED SUBSTITUTIONS.

14 - AG

EXISTING PLANTING TO REMAIN, TYP. LOCATION IS APPROXIMATE

FILL GAPS IN EXISTING PLANTING WITH AGAPANTHUS

15 - AG

6 - NC 66 - RC

EXISTING TREES TO REMAIN, TYP.

125 - TA

7 - YU

15 - YU

6.

PROTECT EXISTING IMPROVEMENTS, TREES, LANDSCAPE, AND TURF TO REMAIN DURING CONSTRUCTION. PROVIDE IRRIGATION AND MAINTENANCE OF EXISTING MATERIALS TO REMAIN WITHIN PROJECT AREA DURING CONSTRUCTION AND UNTIL FINAL ACCEPTANCE. REPLACEMENT OF EXISTING VEGETATION OR PLANTINGS OR RESTORATION OF AREAS IMPACTED BY CONSTRUCTION ACTIVITIES WILL BE AT THE COST OF THE CONTRACTOR.

7.

MAINTAIN EXISTING GRADES UNLESS OTHERWISE APPROVED BY THE OWNER'S REPRESENTATIVE. IF FILL IS REQUIRED, USE A CLEAN, SANDY LOAM EXCAVATED FROM LOCAL SOURCES AND DEEP PITS SUCH THAT IT IS FREE OF WEEDS, SEEDS, LITTER, TOXINS, AND OTHER ITEMS HARMFUL TO PLANTINGS.

8.

REMOVE ALL CONSTRUCTION DEBRIS AND LIMEROCK, GRAVEL, ROAD BEDDING, LITTER, AND OTHER ITEMS POTENTIALLY DAMAGING TO PLANT GROWTH WITHIN THE PROPOSED PLANTING AND TURF AREAS PRIOR TO PLANTING. PROVIDE A MINIMUM THREE FOOT DEEP PLANTING DEPTH FOR ALL PROPOSED PLANTING AND TURF AREAS.

11 - OH

EXISTING SIGN

9.

PROTECT TREES, SHRUBS, AND GROUNDCOVERS DURING AND UPON DELIVERY. KEEP PLANTS WATERED AND WITHIN CONTAINERS UNTIL PLANTING. DO NOT PRUNE PRIOR TO OR FOLLOWING DELIVERY UNLESS APPROVED BY THE OWNER'S REPRESENTATIVE.

10.

IRRIGATION: SEE IRRIGATION PLANS.

11.

MULCH: INSTALL 3" OF PINE STRAW MULCH, SETTLED, IN ALL PROPOSED PLANTING AREAS.

SOD 66 - JB

20 - AG

38 - RC

10 - DE 8 - OH

G

1.

SEAL:

F

E

21-053

PROJECT NO: CLIENT'S NO.:

21 - YU 92 - RC

D

LASER INVESTMENT GROUP

11 - YU

ISSUED FOR:

CONSTRUCTION

ISSUED DATE:

26 AUG 2021

D

REVISIONS:

79 - TA

5 - DE 5 - OH 39 - HD 24 - AG

C

C

32 - RC 113 - JB

124 - JB 107 - TA

SCALE:

43 - HD SOD

APPROXIMATE SIZE AND LOCATION OF PROPOSED GROUND SIGN

PROPOSED PLANTING NOT TO EXTEND BEYOND RIGHT OF WAY LIMIT

B

0

5'

10'

20'

SCALE: 1" = 10'

B

SHEET TITLE:

SR A

20 /

HW

LANDSCAPE PLAN, PLANT SCHEDULE, NOTES AND DETAILS

Y 44

1

A

NORTH

SHEET NUMBER:

L-101 1

2

3

4

5

6

7

8

9

10


1

2

4

3

5

7

6

8

9

Landscape Architecture

MATCHLINE L-201.B

J

10

LEGEND

MATCHLINE L-201.A

Site Planning

J

POC

.1

T

Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412

POINT OF CONNECTION TO EXISTING MAIN LINE AND 2-WIRE CONTROL WIRES

.1

T

TORO DL 2000 1 GPH, 12'' O.C. PR. REG. DRIP TUBING

Certificate of Authorization No. LC26000575

.1

T

CLASS 200 2'' PVC SOLVENT WELD MAIN LINE ROUTING CL 200 SOLVENT WELD PVC ZONE PIPE ROUTING

I

PROJECT NAME:

I

4'' DIRECTIONAL BORE - CONSULT WITH OWNER AS TO POSSIBLE EXISTING AVAILABLE SLEEVING

TECH CITY ENTRY

.1

T

.1

T

HUNTER ICV-151G-FS-AS-ADJ 1.5'' VALVE WITH DUAL-1 DECODER AND DUAL-S SURGE ARRESTOR

.1

T

LOCATION OF DRIP AIR/VACUUM RELIEF VALVE, LINE FLUSHING VALVE AND RAIN BIRD OPERIND

.1

T

2'' GATE VALVE

H

H

VALVE STATION, SIZE, APPLICATION AND GALLONAGE

2

for

11

.1

T

11

4

.1

T

.1

T

.1

T

.1

T

Alachua, FL

G

POC

.1

.1

T

T

.1

T

.1

11 '

T

G

2'

.1

T

MH-10

LASER INVESTMENT GROUP

SEAL:

EXISTING MAINLINE

.1

T

F

1''

T

.1

T

.1

T

F

.1

.1

T

T

.1

.1

T

T

CONNECT EXISTING DRIP TUBING TO THE NEW DRIP TUBING AT THESE POINTS.

.1

T

.1

.1

T

.1

4'' DIR. BORE

.1

T

.1

.1

T

112''

E

S-15

.1

E

FILL GAPS IN EXISTING PLANTING WITH AGAPANTHUS

EXISTING TREES TO REMAIN, TYP.

T

112''

T

.1

T

112''

112''

T

.1

T

EXISTING PLANTING TO REMAIN, TYP. LOCATION IS APPROXIMATE

EXISTING SIGN

.1

.1

T

1''

112''

112''

11 4''

.1

D

T

1''

S-13

S-17

CLIENT'S NO.:

GROUND 2-WIRE SYSTEM AT VALVES' LOCATION.

CONSTRUCTION

ISSUED DATE:

26 AUG 2021

REVISIONS:

.1

T

T

.1

.1

T

112''

1730 L.F. 26 GPM

.1

T

.1

T

1''

ISSUED FOR:

D

11 4''

2110 L.F. 31.7 GPM

21-053

PROJECT NO:

.1

112''

T

SOD

T

11 4''

C

2280 L.F. 34.2 GPM

C

1''

SCALE:

T

1470 L.F. 22.1 GPM

.1

SOD

SR

A

20 /

HW

.1

1

A

MATCHLINE L-201.A

NORTH

SHEET NUMBER:

MATCHLINE L-201.B 1

2

3

4

5

6

7

8

20'

IRRIGATION PLAN AND SCHEDULE

B

Y 44

10'

SHEET TITLE:

.1

A

5'

SCALE: 1" = 10'

B

T

B

0

T

APPROXIMATE SIZE AND LOCATION OF PROPOSED GROUND SIGN

PROPOSED PLANTING NOT TO EXTEND BEYOND RIGHT OF WAY LIMIT

L-201 9

10



TB

SEED, TYP.

5 - GP

TB

1 - LIM

TB

WL

TB

TB

TF - 38

1 - LIM

WM

TB

TB

3 - LIM

SAN

TB

TB

TB

TB

3 - RE 1 - TD

1 - TD

HD - 21

1 - TD

15 - MC 19 - CR

7 - MC

TB

TB

TB

TB

TB

33 .0 TB

SOD, TYP.

TB

TB TB TB

TB

TB

TB

TB

TB

CN - 3

TB

MC - 19 1 - PD 1 - ED

1 - PD 3 - CN

IN - 16 47 - ND CN - 3

1 - PD

27 - ND 1 - TD ND - 5

1 - TD

MATCHLINE SHEET L-102

TB

5 - MC 3 - RE

TB

TB

Site Planning

J

Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412

16 - CR

Certificate of Authorization No. LC26000575

13 - PMP 3 - RE

PROJECT NAME:

I

3 - IV

ORCHID LAKE

TB

TB

TB

TB

TB

TB

1 - TD

6 - IN 9 - PMP TB

TB

1 - LIM

Landscape Architecture

1 - TD

1 - TD

SAN

3 - ED 12 - PMP 9 - MC

1 - TD

1 - IE 3 - SP

SAN 1 - TD

10 - MC

10

1 - LIM

HD - 10 11 - IN WM A/C UNITS, TYP.

2 - SP

WM

SAN 25 - CR

11 - AG 1 - ED

ND - 3

TB

TB

TB

WL

TB

TB

TF - 11 IN - 9 11 - HD 2 - TC

TB

TB

MAINT.

12 - PMP

1 - TD 27 - CR MC - 8

IN - 23

TB

19 - IN

1 - ED 15 - TF

TB

WL

SAN

2 - PD

TB

TB

TB

I

20 - GP

25 - TF

WM

1 - IE

TB

SOD, TYP.

1 - LIM HD - 9

1 - LIM

SOD, TYP.

WM

1 - QV

4 - IN

17 - EB FL

TB

HD - 37

6 - CM

IN - 17

HD - 9

TB

TB

7 - TD

TB

SOD

6 - CM

TF - 23

TB

TB

DRY STORMWATER POND

3 - LIM

SAN

TF - 15

IN - 4

2 - QV

9

MATCHLINE SHEET L-101

ND - 2

6 - TF

3 - IN

WM

TB

SAN

J

HD 7

4 - IN

HD - 5

8

TB

TF - 10

7

6

TB

1 - TD

5

TB

4

3

13 - MC

TB

2

TB

1

1 - TD 1 - PD

TB

H

TB

H

TB

Cocoa, FL

TB

PROPERTY BOUNDARY

TB

NORTH

TB TB

HTG Orchid Lake, Ltd.

TB

PROPERTY BOUNDARY

for

LEGEND

24 LA

TB

G

EXISTING TREES AND

G

TB

VEGETATION TO REMAIN

TB TB

TB

TB

TB

TB

TB

TB TB

TB

MULCH UNDER EXISTING TREES TO REMAIN IN AREA OUTLINED

TB TB

F

TREE BARRICADE, TYP.

TB

TB

TB

TB

TB

TB

TB

TB

TB

AREA ASSUMED AS UNDISTRUBED

F

AREA UNDER EXISTING TREES TO REMAIN AS IS

TB TB

PLANT SCHEDULE

TB

SEED, TYP.

TB

PROVIDE 2 STRIPS OF SOD ALONG DRIVE EDGE, TYP.

TB

TB

TB

TB TB

TB

TB

TB

TB

TB

TREES ED

QTY 11

BOTANICAL NAME Elaeocarpus decipiens

COMMON NAME Japanese Blueberry Tree

SIZE 45 gal., 8` ht., 28" sprd., 3" cal.

SPACING As shown

NOTES

IV

30

Ilex vomitoria

Yaupon Holly

45 gal., 7` ht. x 42" sprd., 3" cal.

As shown

IE

26

Ilex x attenuata 'Eagleston'

Eagleston Holly

45 gal., 8` ht., 28" sprd., 3" cal.

As shown

LIM

50

Lagerstroemia indica x faurei `Muskogee`

Muskogee Crape Myrtle

45 gal., 7` ht. x 42" sprd., 3" cal.

As shown

Standard

MG

10

Magnolia grandiflora

Southern Magnolia

45 gal., 8` ht. x 54" sprd., 3" cal.

As shown

Full to ground

PD

23

Pinus elliotti densa

Slash Pine

45 gal., 8` ht., 28" sprd., 3" cal.

As shown

QV

6

Quercus virginiana

Southern Live Oak

100 gal., 10` ht. x 6` sprd., 4" cal.

As shown

TC

13

Tabebuia chrysotricha

Golden Trumpet Tree

45 gal., 7` ht. x 42" sprd., 3" cal.

As shown

TD

65

Taxodium distichum

Bald Cypress

45 gal., 8` ht., 28" sprd., 3" cal.

As shown

PALMS SP

QTY 30

BOTANICAL NAME Sabal palmetto

COMMON NAME Cabbage Palmetto

SHRUBS CR

QTY 235

BOTANICAL NAME Chrysobalanus icaco 'Red Tip'

COMMON NAME Red Tip Cocoplum

MC

389

Muhlenbergia capillaris

PMP

106

RE

E

TB

E

SEAL:

PROPOSED TREE

TB

TB TB

TB

D

C

UNIVERSITY LN

UNIVERSITY LANE

B

A

SIZE * Height as shown, 12" min. cal. at 4.5` above grade

CLIENT'S NO.:

SPACING As shown

NOTES Regenerated, minimum four fronds

SIZE 3 gal., 24" ht. x 18" sprd.

SPACING 36" o.c.

NOTES

Pink Muhly

3 gal., 24" ht. x 18" sprd.

36" o.c.

Podocarpus macrophyllus 'Pringles'

Pringles Dwarf Podocarpus

3 gal., 24" ht. x 24" sprd.

36" o.c.

72

Russelia equisetiformis

Firecracker Plant

3 gal., 24" ht. x 24" sprd.

36" o.c.

ENHANCED AG

QTY 168

BOTANICAL NAME Agapanthus africanus

COMMON NAME Agapanthus

SIZE 3 gal., 24" ht. x 24" sprd.

SPACING 36" o.c.

CM

201

Carissa macrocarpa

Natal Plum

3 gal., 18" ht. x 18" sprd.

36" o.c.

CN

25

Crinum asiaticum

Crinum Lily

7 gal., 24" ht. x 24" spr.

As shown

IN

294

Ilex vomitoria 'Nana'

Dwarf Yaupon Holly

3 gal., 12" ht. x 12" sprd.

30" o.c.

ND

162

Nerium oleander 'Dwarf'

Dwarf Oleander

3 gal., 24" ht. x 24" sprd.

36" o.c.

RO

105

Rosmarinus officinalis

Rosemary

3 gal., 24" ht. x 18" sprd.

36" o.c.

TF

451

Tripsacum floridanum

Florida Gamagrass

3 gal., 24" ht. x 18" sprd.

36" o.c.

ZF

31

Zamia furfuracea

Cardboard Palm

3 gal., 18" ht. x 18" sprd.

48" o.c.

ENHANCED EB

QTY 241

BOTANICAL NAME Evolvulus glomeratus `Blue Daze`

COMMON NAME Blue Daze Morning Glory

SIZE 1 gal., 6" ht. x 12" sprd.

SPACING 30" o.c.

GP

275

Gaillardia pulchella

Indian Blanketflower

1 gal., 12" ht. x 18" sprd.

30" o.c.

HD

413

Helianthus debilis

Dune Sunflower

1 gal., 12" ht. x 18" sprd.

30" o.c.

JB

283

Juniperus conferta `Blue Pacific`

Blue Pacific Juniper

1 gal., 6" ht. x 12" sprd.

30" o.c.

SOD/SEED SEED

QTY 7,819 sf

BOTANICAL NAME Paspalum notatum `Argentine`

COMMON NAME Argentine Bahia Grass

SIZE Seed

SPACING

SOD

235,221

Paspalum notatum `Argentine`

Argentine Bahia Grass

sod

2

3

4

5

6

7

ISSUED FOR:

BID

ISSUED DATE:

13 APR 2022

D

REVISIONS:

NOTES C

SCALE:

0

15'

60'

NOTES SHEET TITLE:

LANDSCAPE PLAN AND SCHEDULE NOTES Clean and dry seed Sand grown and weed free

A SHEET NUMBER:

L-102 8

30'

SCALE: 1" = 30'

B

* Sabal Palms to be 8', 12', 16', and 20' clear trunk heights. Cluster in groups of staggered heights

1

21-086

PROJECT NO:

9

10


2

4

3

5

NOTE: 1. ENSURE PLANTING PIT DRAINS WELL PRIOR TO INSTALLATION. 2. REMOVE TREE FROM CONTAINER OR REMOVE UPPER 1/3 OF BURLAP AND WIRE MESH FOR B&B TREES. 3. SLICE ROOTBALL VERTICALLY ON OUTSIDE EDGES OF AND AROUND ROOTBALL. 4. TREE TO BE PLUMB. STAKE TREE IF NEEDED. SUBMIT TREE STAKING DETAILS AND LAYOUT FOR APPROVAL.

TOP OF ROOTBALL 1-2" ABOVE FINISH GRADE

I

MULCH, 3" THICKNESS TYPICAL AND ONLY 1" OVER ROOTBALL 3" - 6" SOIL BERM TO OUTSIDE OF ROOTBALL FINISH GRADE

CL LOOSEN SIDE SLOPES OF PLANTING PIT

EQUAL

TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. ROOTBALL SITS ON BOTTOM OF PLANTING PIT

EQUAL

2 x 4 x 12, TYP. BATTEN (2) 1" NYLON STRAPS CUT BRACE TO BE FLUSH WITH BATTEN AND ATTACH WITH SCREWS (3) 2 x 4 BRACES, VERTICAL, AND EVENLY SPACED AROUND TRUNK

CL

SCARIFY SIDE SLOPES

ROOTBALL ON EXISTING SOIL

ER NT G CE ON PACIN S

12" OFFSET FOR GROUNDCOVERS 18" OFFSET FOR SHRUBS

SOUTH 1 Tree / 50 LF

EQUAL

360

Mitigation inches defecit

138

Mitigation inches defecit

2023

Mitigation inches converted to 4" trees

35

Mitigation inches converted to 3" trees

674

Arbor Mitigation Fund Contribution preliminary total

Perimeter (LF)

Trees Required

PROVIDED

332

6.6

8 trees

Perimeter (LF)

Trees Required

PROVIDED

NORTH 1 Tree / 50 LF

390

7.8

8 trees

EAST 1 Tree / 50 LF

584

11.7

12 trees

REQUIREMENT

SHRUB AND GROUNDCOVER LAYOUT DETAIL

Per Cocoa, FL Code of Ordinances, Part II- Code, Appendix A- Zoning, Article XIII.Supplementary District Regulations. Sec. 22.- Landscape requirements (C) (5) Perimeter landscaping adjacent to abutting commercial properties. One tree between the common lot line and the off-street parking for each fifty linear feet of lot depth. Each tree shall be planted in at least twenty-five square foot planting area with a minimum dimensions of at least five feet.

C

REQUIREMENT 1 Tree / 50 LF

Perimeter (LF)

Trees Required

PROVIDED

230

4.6

14 trees along E perimeter parking area

INTERIOR PARKING AREA LANDSCAPING

Per Cocoa, FL Code of Ordinances, Part II- Code, Appendix A- Zoning, Article XIII.Supplementary District Regulations. Sec. 22.- Landscape requirements (C) (6) Interior parking area landscaping. Off-street parking areas and other vehicular use areas shall have at least ten square feet of interior landscaping for each parking space excluding those spaces abutting a perimeter for which landscaping is required. Each separate landscaped area shall contain at least one tree with the remaining area adequately landscaped groundcover or other authorized landscaping material.The total number of trees shall not be less than one for each one hundred square feet or fraction thereof of required interior landscaped area.

B

Total # interior parking spaces

105

Landscape area required (SF)

1050

Landscape area provided (SF)

3664

Minimum # trees

10.5

Trees provided

A

4

Certificate of Authorization No. LC26000575

$35,271

PROJECT NAME:

$290,580

I

6

$325,851

H

2.

PLANTING PREPARATION: REMOVE ALL CONSTRUCTION DEBRIS, LIMEROCK, GRAVEL, ROAD BEDDING, LITTER, AND OTHER ITEMS POTENTIALLY DAMAGING TO PLANT GROWTH WITHIN PROPOSED LANDSCAPE AND TURF AREAS PRIOR TO PLANTING. MAINTAIN EXISTING GRADES UNLESS OTHERWISE APPROVED BY THE OWNER'S REPRESENTATIVE. IF FILL IS REQUIRED, USE A CLEAN, SANDY LOAM WITH pH 5.5-6.5 AND EXCAVATED FROM LOCAL SOURCES AND DEEP PITS SUCH THAT IT IS FREE OF WEEDS, SEEDS, LITTER, TOXINS, AND OTHER ITEMS HARMFUL TO PLANTINGS.

3.

PRUNING: IF TREE OR ROOT PRUNING IS REQUIRED, THESE ACTIVITIES SHALL BE PERFORMED BY AN ARBORIST CERTIFIED BY THE INTERNATIONAL SOCIETY OF ARBORICULTURE (ISA). TREE PRUNING SHALL BE DONE IN ACCORDANCE WITH THE MOST CURRENT VERSION OF THE AMERICAN NATIONAL STANDARD FOR TREE CARE OPERATIONS "TREE. SHRUB AND OTHER WOODY PLANT MAINTENANCE" (ANSI 300) AND "PRUNING. TRIMMING. REPAIRING. MAINTAINING, AND REMOVING TREES. AND CUTTING BRUSH—SAFETY REQUIREMENTS" (ANSI Z133). NO MORE THAN 25 PERCENT OF THE CROWN SHOULD BE REMOVED AT ONE TIME. ON YOUNG TREES, LIMB REMOVAL SHALL LEAVE NO MORE THAN 33 PERCENT OF THE TRUNK BARE OF BRANCHES. MINIMIZE IMPACTS ON EXISTING TREE ROOTS AS MUCH AS POSSIBLE. AVOID TREE ROOT PLATE AREAS AS DEFINED BY PERMITTING AGENCIES. ALL ROOTS OF TREES TO REMAIN THAT ARE ADJACENT TO EXTENSIVE EXCAVATION AND ARE 1” DIAMETER OR OVER SHALL BE HAND CUT. EXPOSE ROOTS BY HAND DIGGING, HAND CUT OR SAW CLEANLY, AND IMMEDIATELY COVER WITH SOIL. DO NOT ALLOW CUT ROOTS TO DRY OUT. SUPPLEMENTAL IRRIGATION IS REQUIRED FOR TREES THAT HAVE UNDERGONE ROOT PRUNING AND SHALL BE PROVIDED IMMEDIATELY FOLLOWING ROOT TRIMMING ACTIVITIES.

7

Cocoa, FL

for

HTG Orchid Lake, Ltd. G

PLANT MATERIAL, GENERAL: ALL PLANT MATERIALS SHALL MEET 'FLORIDA NUMBER 1' REQUIREMENTS AS PER THE MOST CURRENT EDITION OF 'FLORIDA GRADES AND STANDARDS FOR NURSERY PLANTS', FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. GRASS SOD SHALL BE CLEAN AND REASONABLY FREE OF WEEDS AND NOXIOUS PESTS OR DISEASES.

5.

PROPOSED TREES: PROPOSED TREES SHALL BE A MINIMUM OF SIX FEET TALL. TREES OF SPECIES WHOSE ROOTS ARE KNOWN TO CAUSE DAMAGE TO PUBLIC ROADWAYS OR OTHER PUBLIC WORKS SHALL NOT BE PLANTED CLOSER THAN TWENTY (20) FEET TO SUCH PUBLIC WORKS.

6.

NEW TREE STAKING: IF NECESSARY TO MAINTAIN TREES PLUMB, TREES SHALL BE STAKED WITH BIODEGRADABLE STAKING MATERIALS.

7.

PROPOSED SHRUBS: PROPOSED SHRUBS SHALL BE A MINIMUM OF TWO FEET TALL.

8.

TURF: ALL UNPAVED AND DISTURBED AREAS OUTSIDE OF PROPOSED TREE, SHRUB, AND GROUNDCOVER PLANTINGS SHALL BE GRASSED. SEE CIVIL PLANS FOR GRASSING INFORMATION FOR STORMWATER FACILITIES. SOD SHALL BE SAND-GROWN, STRONGLY ROOTED, WITHOUT SYNTHETIC STABILIZING MATERIALS, FREE OF PESTS, AND CERTIFIED FREE OF NOXIOUS WEEDS BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES, DIVISION OF PLANT INDUSTRY. SEE PLAN FOR PROPOSED SOD AREAS, WHICH SHALL INCLUDE AT A MINIMUM A 3' STRIP ALONG ALL PAVING EDGES AND BUILDING PERIMETERS, ANY SLOPES 4:1 OR GREATER, AND ANY STORMWATER, SWALE, OR OTHER AREAS SUBJECT TO EROSION. SEE TECHNICAL SPECIFICATIONS FOR ADDITIONAL SOD AND SEED REQUIREMENTS.

9.

MULCHING: THREE INCHES OF MULCH, SETTLED, SHOULD COVER TREE RING PLANTING AREAS AND ALL SHRUB AND GROUNDCOVER PLANTING AREAS. MULCH SHOULD BE NO DEEPER THAN ONE INCH OVER THE TOP OF TREE ROOTBALLS. USE PINESTRAW MULCH IN ALL AREAS. MULCH TO BE FREE OF DEBRIS, STICKS, AND CONES. NO PLASTIC OR NON-BIODEGRADABLE WEED CLOTH OR SURFACE COVERS TO BE USED.

10.

COMPLIANCE: NO CERTIFICATE OF OCCUPANCY SHALL BE ISSUED UNTIL THE LANDSCAPING IS COMPLETE AND IT SHALL BE UNLAWFUL TO OCCUPY THE PREMISES UNLESS THE LANDSCAPE PLAN HAS BEEN APPROVED, COMPLIED WITH, AND RECEIVED A FINAL INSPECTION FROM THE ENFORCEMENT OFFICIAL.

11.

MAINTENANCE: THE OWNER SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL LANDSCAPING WHICH SHALL BE SO MAINTAINED AS TO PRESENT A NEAT AND ORDERLY APPEARANCE AND SHALL BE KEPT FREE FROM REFUSE AND DEBRIS. ALL LANDSCAPED AREAS SHALL BE PROVIDED WITH A READILY AVAILABLE WATER SUPPLY WITH AT LEAST ONE (1) OUTLET LOCATED WITHIN ONE HUNDRED (100) FEET OF ALL PLANT MATERIAL TO BE MAINTAINED. IT SHALL BE THE DUTY OF THE PROPERTY OWNER TO PROVIDE PROPER MAINTENANCE OF THE LANDSCAPE PLANTINGS INSTALLED AT ALL TIMES. THIS INCLUDES, BUT IS NOT LIMITED TO, THE REPLACEMENT OF PLANTS DAMAGED BY INSECTS, DISEASES, VEHICULAR TRAFFIC, ACTS OF GOD, OR VANDALISM, THAT ARE BEYOND A REASONABLE EXPECTATION OF RECOVERY. NECESSARY REPLACEMENTS SHALL BE MADE WITHIN NINETY (90) DAYS OF NOTIFICATION BY THE ENFORCEMENT OFFICIAL. IN NO CASE SHALL GRASS CLIPPINGS, VEGETATIVE MATERIAL, AND/OR VEGETATIVE DEBRIS BE WASHED, SWEPT, OR BLOWN OFF INTO SURFACE WATERS, STORMWATER DRAINS, DITCHES, CONVEYANCES, WATERCOURSES, WATER BODIES, WETLANDS, SIDEWALKS, OR ROADWAYS. ANY MATERIAL THAT IS ACCIDENTALLY SO DEPOSITED SHALL BE IMMEDIATELY REMOVED TO THE MAXIMUM EXTENT PRACTICABLE.

12.

FERTILIZER: FOLLOW CITY OF COCOA REQUIREMENTS AS LISTED BELOW:

x

NO APPLICATOR SHALL APPLY FERTILIZERS CONTAINING NITROGEN AND/OR PHOSPHOROUS TO TURF AND/OR LANDSCAPE PLANTS DURING THE PROHIBITED APPLICATION PERIOD, OR TO SATURATED SOILS. IN ADDITION, FERTILIZER CONTAINING NITROGEN OR PHOSPHOROUS SHALL NOT BE APPLIED TO TURF OR LANDSCAPE PLANTS DURING THE RESTRICTED APPLICATION PERIOD, DEFINED AS JUNE 1 TO SEPTEMBER 30. FERTILIZER SHALL NOT BE APPLIED WITHIN TEN (10) FEET OF ANY SURFACE WATERS, POND, STREAM, WATERCOURSE, LAKE, CANAL, OR WETLAND AS DEFINED BY THE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION (CHAPTER 62-340, FLORIDA ADMINISTRATIVE CODE). NEWLY PLANTED TURF AND/OR LANDSCAPE PLANTS MAY BE FERTILIZED IN THIS ZONE FOR A SIXTY-DAY PERIOD BEGINNING THIRTY (30) DAYS AFTER PLANTING IF NEEDED TO ALLOW THE PLANTS TO BECOME WELL ESTABLISHED. CAUTION SHALL BE USED TO PREVENT DIRECT DEPOSITION OF NUTRIENTS INTO THE WATER. A VOLUNTARY TEN-FOOT LOW MAINTENANCE ZONE IS STRONGLY RECOMMENDED, BUT NOT MANDATED, FROM ANY SURFACE WATERS, POND, STREAM, WATERCOURSE, LAKE, WETLAND OR FROM THE TOP OF A SEAWALL. A SWALE/BERM SYSTEM IS RECOMMENDED FOR INSTALLATION AT THE LANDWARD EDGE OF THIS LOW MAINTENANCE ZONE TO CAPTURE AND FILTER RUNOFF. NO MOWED OR CUT VEGETATIVE MATERIAL SHOULD BE DEPOSITED OR LEFT REMAINING IN THIS ZONE OR DEPOSITED IN THE WATER. CARE SHOULD BE TAKEN TO PREVENT THE OVER-SPRAY OF AQUATIC WEED PRODUCTS IN THIS ZONE.

x

NO FERTILIZER CONTAINING PHOSPHOROUS SHALL BE APPLIED TO TURF OR LANDSCAPE PLANTS IN COCOA UNLESS A SOIL OR PLANT TISSUE DEFICIENCY AS VERIFIED BY A UNIVERSITY OF FLORIDA, INSTITUTE OF FOOD AND AGRICULTURE SCIENCES, APPROVED TESTING METHODOLOGY. IN THE CASE THAT A DEFICIENCY HAS BEEN VERIFIED, THE APPLICATION OF A FERTILIZER CONTAINING PHOSPHOROUS SHALL BE IN ACCORDANCE WITH THE RATES AND DIRECTIONS PROVIDED BY RULE 5E-1.003(2). FLORIDA ADMINISTRATIVE CODE. DEFICIENCY VERIFICATION SHALL BE NO MORE THAN TWO (2) YEARS OLD. HOWEVER, RECENT APPLICATION OF COMPOST MANURE, OR TOP SOIL SHALL WARRANT MORE RECENT TESTING TO VERIFY CURRENT DEFICIENCIES.

x

THE NITROGEN CONTENT OF FERTILIZER APPLIED TO TURF OR LANDSCAPE PLANTS WITHIN COCOA SHALL CONTAIN AT LEAST FIFTY (50) PERCENT SLOW RELEASE NITROGEN PER GUARANTEED ANALYSIS LABEL.

x

FERTILIZERS APPLIED TO TURN WITHIN COCOA SHALL BE APPLIED AT RATES THAT ARE IN ACCORDANCE WITH REQUIREMENTS AND DIRECTIONS PROVIDED BY RULE 5E-1.003(2), FLORIDA ADMINISTRATIVE CODE, LABELING REQUIREMENTS FOR URBAN TURF FERTILIZERS.

x

FERTILIZER CONTAINING NITROGEN OR PHOSPHOROUS SHALL NOT BE APPLIED BEFORE SEEDING OR SODDING A SITE, AND SHALL NOT BE APPLIED FOR THE FIRST THIRTY (30) DAYS AFTER SEEDING OR SODDING, EXCEPT WHEN HYDRO-SEEDING FOR TEMPORARY OR PERMANENT EROSION CONTROL IN AN EMERGENCY SITUATION (WILDFIRE, ETC.), OR IN ACCORDANCE WITH THE STORMWATER POLLUTION PLAN FOR THAT SITE.

x

SPREADER DEFLECTOR SHIELDS ARE REQUIRED WHEN FERTILIZING VIA ROTARY (BROADCAST) SPREADERS. DEFLECTORS MUST BE POSITIONED SUCH THAT FERTILIZER GRANULES ARE DEFLECTED AWAY FROM ANY IMPERVIOUS SURFACES, FERTILIZER-FREE ZONES, SURFACE WATERS AND WATER BODIES, INCLUDING WETLANDS.

x

FERTILIZER SHALL NOT BE APPLIED, SPILLED, OR OTHERWISE DEPOSITED ON ANY IMPERVIOUS SURFACES. ANY FERTILIZER APPLIED, SPILLED, OR DEPOSITED, EITHER INTENTIONALLY OR ACCIDENTALLY, ON ANY IMPERVIOUS SURFACE SHALL BE IMMEDIATELY AND COMPLETELY REMOVED TO THE GREATEST EXTENT PRACTICABLE AND EITHER LEGALLY APPLIED TO TURF OR ANY OTHER LEGAL SITE, OR RETURNED TO THE ORIGINAL OR OTHER APPROPRIATE CONTAINER. IN NO CASE SHALL FERTILIZER BE WASHED, SWEPT, OR BLOWN OFF IMPERVIOUS SURFACES INTO STORMWATER DRAINS, DITCHES, CONVEYANCES, OR WATER BODIES.

x

11

5

ORCHID LAKE

EXISTING UTILITIES: LOCATE ALL UTILITIES PRIOR TO COMMENCEMENT OF WORK. CALL SUNSHINE STATE ONE CALL - SEE LOGO.

x

PERIMETER LANDSCAPING ADJACENT TO ABUTTING COMMERCIAL PROPERTIES

SCALE: N.T.S

Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412

1.

4.

Per Cocoa, FL Code of Ordinances, Part II- Code, Appendix A- Zoning, Article XIII.Supplementary District Regulations. Sec. 22.- Landscape requirements (C) (4) Required landscaping adjacent to public rights-of-way. A landscaped strip at least five feet in width between the abutting right-of-way and the off-street parking area, including one tree for each fifty linear feet or fraction thereof, located between the abutting right-of-way and off-street parking area in a planting area of at least twenty-five square feet with a dimension of at least five feet, and a hedge of at least two feet in height along the perimeter of such landscaped strip. Provided: Hedge, see plans. See below for tree calculations.

TRIANGULAR LAYOUT, TYPICAL, IN STRAIGHT RUNS AND AS MUCH AS POSSIBLE AROUND CURVES. ON CENTER SPACING DISTANCE SHALL BE AS INDICATED IN SCHEDULE.

3

Total inches of proposed 12" palms as shown in plan

REQUIRED LANDSCAPING ADJACENT TO PUBLIC RIGHTS-OF-WAY

ON CENTER SPACING

BEDLINE OR PAVING EDGE

2

24

J

LANDSCAPE NOTES

LOOSEN SIDE SLOPES OF PLANTING PIT TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. ROOTBALL SITS ON BOTTOM OF PLANTING PIT

Per Cocoa, FL Code of Ordinances, Part II- Code, Appendix A- Zoning, Article XIII.Supplementary District Regulations. Sec. 22.- Landscape requirements (C) Landscaping requirements for certain yard areas and off-street parking and other vehicular use areas. A landscaped strip of land at least five (5) feet in width shall be provided between the abutting right-of-way and the off-street parking area, including one tree for each fifty linear feet or fraction thereof, located between the abutting right-of-way and off-street parking area, planted in a planting area of at least twenty-five square feet with a dimension of at least five feet; and a hedge of at least two feet in height along the perimeter of such landscaped strip. Provided: Hedge, see plans. See below for tree calculations.

OUTSIDE ROW FOLLOWS CURVE AS SHOWN. ROWS REMAIN PARALLEL AROUND CURVE.

1

Total inches of proposed 4" trees as shown in plan

Site Planning

This preliminary mitigation cost is based on unit costs per 3" or 4" replacement tree as listed above, which include plant material, delivery, installation, and two years of maintenance. Please refer to the 'Request for Contribution to the Arbor Mitigation Fund' memo dated April 1, 2022. Further discussion of the final mitigation payment is respectfully requested given that this project is a deed-restricted affordable housing development.

LANDSCAPING REQUIREMENTS FOR OFF-STREET PARKING AND VEHICULAR USE AREAS

TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL.

REQUIREMENT

4

672

PLANTING DETAIL 2 PALM SCALE: N.T.S.

AND GROUNDCOVER PLANTING DETAIL 3 SHRUB SCALE: N.T.S

D

Total inches of proposed 3" trees as shown in plan

Arbor Mitigation Fund Contribution - preliminary total

The following calclations are per Cocoa, FL, Code of Ordinances, Part II- Code, Appendix A- Zoning, Article XIII.- Supplementary District Regulations. Sec. 22.- Landscape requirements (C) Landscaping requirements for certain yard areas and off-street parking and other vehicular use areas

E

162

Landscape Architecture

TOTAL REQUIRED MITIGATION

BRACE NAILED TO 2 x 4 WOOD STAKE WITH TOP BELOW GRADE

2 X ROOTBALL WIDTH

3 X ROOTBALL DIMENSION

Mitigation inches required - to be replaced with 4" caliper trees minimum

Arbor Mitigation Fund Contribution preliminary total

LANDSCAPE CALCULATIONS

F

3055

FINISH GRADE

SCALE: N.T.S

CUT INTO GRADE AT EDGE OF BED SUCH THAT MULCH SURFACE MEETS FINISH GRADE.

Mitigation inches required - to be replaced with 3" caliper trees minimum

3" - 6" SOIL BERM TO OUTSIDE OF ROOTBALL

EQUAL

FINISH GRADE

G

10

REQUIRED MITIGATION - 4" MINIMUM REPLACEMENT TREES

MULCH, 4" THICKNESS TYPICAL AND ONLY 1" OVER ROOTBALL

TREE PLANTING DETAIL MULCH, 3" THICKNESS TYPICAL. 1" MAXIMUM OVER ROOTBALL. SOIL BERM TO OUTSIDE OF ROOTBALL.

9

REQUIRED MITIGATION- 3" MINIMUM REPLACEMENT TREES

TOP OF ROOTBALL 1-2" ABOVE FINISH GRADE

2 X ROOTBALL WIDTH

1

8

SAFETY FLAG AT MIDPOINT

30" MIN. DEPTH

H

(5) LAYERS OF BURLAP

NOTE: SUBMIT SHOP DRAWINGS FOR STAKING LAYOUT AND DETAILS.

CLEAR TRUNK HEIGHT

J

7

6

1/3 TRUNK HEIGHT, MINIMUM

1

ALL COMMERCIAL AND INSTITUTIONAL APPLICATORS OF FERTILIZER WITHIN CITY OF COCOA SHALL ABIDE BY AND SUCCESSFULLY COMPLETE THE SIX-HOUR TRAINING PROGRAM IN THE "FLORIDA-FRIENDLY BEST MANAGEMENT PRACTICES FOR PROTECTION OF WATER RESOURCES BY THE GREEN INDUSTRIES" OFFERED BY THE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION THROUGH THE UNIVERSITY OF FLORIDA EXTENSION "FLORIDA-FRIENDLY LANDSCAPES" PROGRAM, OR AN APPROVED EQUIVALENT. PRIVATE, NON-COMMERCIAL APPLICATORS ARE ENCOURAGED TO FOLLOW THE RECOMMENDATIONS OF THE UNIVERSITY OF FLORIDA IFAS FLORIDA YARDS AND NEIGHBORHOODS PROGRAM WHEN APPLYING FERTILIZERS. ALL COMMERCIAL APPLICATORS OF FERTILIZER WITHIN THE CITY OF COCOA SHALL HAVE AND CARRY IN THEIR POSSESSION AT ALL TIMES WHEN APPLYING FERTILIZER, EVIDENCE OF CERTIFICATION BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES AS A COMMERCIAL FERTILIZER APPLICATOR PURSUANT TO RULE 5E-14.117(18), FLORIDA ADMINISTRATIVE CODE. INSTITUTIONAL APPLICATORS WHO APPLY FERTILIZER TO TURF AND/OR LANDSCAPE PLANTS (INCLUDING BUT NOT LIMITED TO RESIDENTIAL LAWNS, GOLF COURSES, COMMERCIAL PROPERTIES, AND MULTI-FAMILY AND CONDOMINIUM PROPERTIES) MUST ENSURE THAT AT LEAST ONE EMPLOYEE HAS A "FLORIDA-FRIENDLY BEST MANAGEMENT PRACTICES FOR PROTECTION OF WATER RESOURCES BY THE GREEN INDUSTRIES" TRAINING CERTIFICATE PRIOR TO THE BUSINESS OWNER OBTAINING A BUSINESS TAX RECEIPT. OWNERS FOR ANY CATEGORY OF OCCUPATION WHICH MAY APPLY ANY FERTILIZER TO TURF AND/OR LANDSCAPE PLANTS SHALL PROVIDE PROOF OF COMPLETION OF THE PROGRAM TO THE CITY OF COCOA'S BUILDING DEPARTMENT

8

9

10

SEAL:

F

E

PROJECT NO:

21-086

CLIENT'S NO.: ISSUED FOR:

BID

ISSUED DATE:

13 APR 2022

D

REVISIONS:

C

SCALE:

AS NOTED B

SHEET TITLE:

LANDSCAPE NOTES, DETAILS AND CALCULATIONS A SHEET NUMBER:

L-103


UP

81.40

82.77

OW

OW

OW

OW

SDO

OW

OW

8" PVC

UP

S

79.35

SF 83.27

5' CW

OW

79.24

D

D

D

SDO

8" PVC

TB

SF

EXISTING TREES AND

75

VEGETATION TO REMAIN

SF

24

SF

P-6

Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412

EXISTING TREE TO BE REMOVED

Certificate of Authorization No. LC26000575

0.5'E

SF

SILT FENCE SEE CIVIL PLANS, TYP.

PROJECT NAME:

#

82.08

Site Planning

J

4' WF

UTILITY ESMT 13 ORB 2508, PG 1284

81.97

76.15 76.58 76.75 76.82 76.93 OW 76.75 O

Landscape Architecture

SF

TB

124

82.15

OW 82.21

OW

83.23

D

D

D

D

6.3'

83.10

P-5

87.17

TB

#

OW

RCP

D

O

SW 147TH DR

3.1'

TB

36 0.4'W

OW

UP

85.01

N89°11'07"E 1001.81'

89.73

OW

D

78.59 78.94 79.07 D 79.12

MANLEY DESIGN

LEGEND

TOP=78.85 N. INV=69.80 E. INV=69.75

P-9

OW

24" RCP 82.13

D

EP

P-8

OW

24" RCP

89.83

35

85.92

D

D

85.99 OW

82.99 D 83.04

D

D

P-7

4' BARBED WIRE FENCE

85.39

85.58

86.07

86.37

D 86.90 86.58 87.04 OW 86.78 T 87.23 87.11 87.29 88.46 87.59

87.04 87.20

24" RCP D 5' CW

81.50

87.24 87.14

OW

D

10

O

37

D

D

UP

D

89.56

89.20

OW

OW

85.73

85.97

80.71 81.17 D 81.21 81.39 OW 81.47

SF

UP

UP

D

OW

86.30 D

81.40 81.89 24" 81.99 D 82.02 82.03 OW

SF

89.73

OW

OW

OW

OW

D

D

86.82

81.62

82.53

84.28 84.76 84.85 D 84.97 85.10OW

SF

OW

OW

24" RCP

D

D

D

D

D

24" RCP

NEWBERRY ROAD / SR 26

85.30

ASPHALT

DRMP TEST HOLE # EH-3 ELEV=80.77

SF

OW

OW

OW

89.34

89.55

88.40 88.43 D 88.62 88.69 OW 88.86

85.86

TOP=82.08 N. INV=76.88 E. INV=76.33 W. INV=76.38

SF

89.58

5' CW

86.41

87.97

TOP=85.93 N. INV=80.98 E. INV=80.88 W. INV=80.83

79.27

81.45

81.99

83.28

2' CURB & GUTTER (TYP)

SF

89.25 OW

UP

D

D

D

89.31

85.09

86.47

SF

SDO 89.15

89.03 D89.41

6 .9 86.87 86

SF

2' CURB & GUTTER (TYP)

88.65 88.63

OW

EP

87.46

9

SF

ASPHALT

J

88. 00

88.22

OW

TOP=88.98 N. INV=83.98 E. INV=82.88 W. INV=82.83

EP

88.22

8

SF

89.82

88.82

7

6

SF

OW

89.43

89.30 88.79

5

SF

90.31

89.91

89.23

4

3

SF

2

S

1

121 SF

TB

SF SF SF

SF SF SF O

33

SF

#

30

82.33

TB

81.76

SF

H

79.96

Alachua County, FL

#

SF

P-15

SW 1ST PL

TB

32

83.18

87.90

P-2

IRRIGATION VALVE

P-14

TB

H

O

TB

29 31 IRRIGATION CONTROL BOX

LAUREATE VILLAGE TND Phase 2, Unit 2

SF

88.34

88.29

P-13

#

TB

P-1

TB

87.77

6' WF 4' BARBED WIRE FENCE

80.35 80.11

P-12

#

122

123

I 73.66

O

TB

34

P-11

TB

EXISTING TREE TO REMAIN, TYP. EXISTING TREE CANOPY TO REMAIN, TYP. SPECIALTY TREE BARRICADE - SEE SHEET LS-1, DETAIL 2

P-10

88.13

TB

4' WIRE FENCE

O

CRUSHED RECYCLED CONCRETE PATHS - SEE DETAIL 5/LS-6.

TB

I

SF

L

SF

TB

P-16

O

W

TB

125

80.48 L

#

SF

O

SF SF SF SF SF SF

SF SF

P-21 P-20

SF

#

P-19

SF

P-4

79.36

O

80.34 78.03

P-22

TB

TB

78.95

F

SF

25 #

F

81.92

81.13

80.07

SEAL:

O

128

TB

#

80.11

127

TB

83.59

P-18

P-17

WL

TB

26

O

TB TB

126

G

SF

#

WL

TB TB

27 83.63

HKP Development

O

TB TB

P-3

82.32

SW 147TH TER

#

WL

TB

TREE REMOVALS AND MITIGATION FOR THIS PARCEL CALCULATED BY OTHERS

86.31

for

74.79

SF

TB

81.32

28

G

SF

W

85.35

TB

TYPICAL TREE BARRICADE 85.79 SEE SHEET LS-1, DETAIL 1

O

#

P-23

81.45

SF

O

SW 2ND LN

SF

P-24

SF

SF

81.91

81.07

79.62

79.04

SF SF

SF

82.13

81.27

23

O

P-25

#

SF

24

82.58 #

SF SF SF

SF

S02°45'46"W 1265.84'

SF SF

P-26

SF SF SF

CLIENT'S NO.:

SF 84.90

SF

MATCHLINE SHEET LS-1 86.98

85.61

NOTE:

5.

PRUNING: IF TREE OR ROOT PRUNING IS REQUIRED, THESE ACTIVITIES SHALL BE PERFORMED BY AN ARBORIST CERTIFIED BY THE INTERNATIONAL SOCIETY OF ARBORICULTURE (ISA). TREE PRUNING SHALL BE DONE IN ACCORDANCE WITH THE MOST CURRENT VERSION OF THE AMERICAN NATIONAL STANDARD FOR TREE CARE OPERATIONS "TREE. SHRUB AND OTHER WOODY PLANT MAINTENANCE" ANSI 300) AND "PRUNING. TRIMMING. REPAIRING. MAINTAINING, AND REMOVING TREES. AND CUTTING BRUSH—SAFETY REQUIREMENTS" (ANSI Z133). NO MORE THAN 25 PERCENT OF THE CROWN SHOULD BE REMOVED AT ONE TIME. ON YOUNG TREES, LIMB REMOVAL SHALL LEAVE NO MORE THAN 33 PERCENT OF THE TRUNK BARE OF BRANCHES.

6.

1.

UTILIZE THIS DETAIL FOR ALL EXISTING, HIGH QUALITY TREES THAT ARE 20" DBH AND LARGER.

2.

PRESERVE EACH REGULATED TREE AND ASSOCIATED NATIVE VEGETATION WITHIN THE AREA OF THE DRIPLINE IN ITS ORIGINAL LOCATION.

12'-0" MAXIMUM

3.

4.

WOOD POSTS OR ANGLE IRON FENCE POSTS , TYP.

5.

FINISH GRADE

6.

7.

1

EXISTING UTILITIES: LOCATE ALL UTILITIES PRIOR TO COMMENCEMENT OF WORK. CALL SUNSHINE STATE ONE CALL.

3.

DO NOT STORE MATERIALS OR ALLOW ENCROACHMENT OF VEHICLES OR MACHINERY WITHIN TREE BARRIER AREA. NO BUILDING MATERIALS, FILL, MACHINERY OR HARMFUL CHEMICALS SHALL BE PLACED WITHIN PROTECTIVE BARRIERS.

CHAIN-LINK FENCING, 11-GAUGE AND 2" MESH SIZE

4.

1-7/8" DIA. METAL LINE POSTS, TYP. 10'-0" MAXIMUM

NO GRADE CHANGES MAY OCCUR WITHIN TREE BARRIER AREA WITHOUT APPROVAL.

TREE BARRICADE TO CANOPY DRIPLINE 2-3/8" DIA. METAL CORNER POSTS , TYP.

NO ATTACHMENTS OR WIRES OTHER THAN THOSE OF A PROTECTIVE AND NON-DAMAGING NATURE MAY BE ATTACHED TO ANY TREE.

8" THICK LAYER OF WOOD CHIPS TO COVER AREA WITHIN TREE BARRIER FINISH GRADE

LANDSCAPE PREPARATION IN THE UNDISTURBED AREA SHALL BE PROHIBITED UNLESS SPECIFICALLY APPROVED OTHERWISE BY THE COUNTY. LANDSCAPING SHALL BE LIMITED TO PLACEMENT OF SOD, MULCH, OR OTHER GROUND COVERS.

4'-0" DEPTH CORNER POSTS

ON-SITE LITTER REMOVAL: REMOVE ALL EXISTING LITTER AND DEBRIS VISIBLE ON THE PROJECT SITE.

BRIGHTLY COLORED MESH CONSTRUCTION FENCING

TREE BARRICADE TO CANOPY DRIPLINE UNLESS OTHERWISE APPROVED BY COUNTY FORESTER/ LANDSCAPE INSPECTOR

CONTACT THE ALACHUA COUNTY FORESTER/LANDSCAPING INSPECTOR AT (352) 374-5243 EXT. 3503 FOR A TREE BARRICADE INSPECTION PRIOR TO COMMENCEMENT OF CONSTRUCTION.

3'-0" DEPTH LINE POSTS

INVASIVE SPECIES: REMOVE INVASIVE, NONNATIVE PLANT SPECIES AS LISTED ON THE FLORIDA PROHIBITED AQUATIC PLANTS LIST OR THE FLORIDA NOXIOUS WEED LIST FROM THE SITE PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. ALL HERBICIDE APPLICATIONS TO CONTROL INVASIVE, NONNATIVE PLANTS IN WETLAND OR UPLAND SET-ASIDE AREAS, INCLUDING BUFFERS, SHALL BE APPLIED BY A CONTRACTOR LICENSED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES, DIVISION OF AGRICULTURAL ENVIRONMENTAL SERVICES, WITH A CURRENT CERTIFICATION IN NATURAL AREAS WEED MANAGEMENT.

4.

A

2.

PRESERVE EACH REGULATED TREE AND ASSOCIATED NATIVE VEGETATION WITHIN THE AREA OF THE DRIPLINE IN ITS ORIGINAL LOCATION.

4'-0" HEIGHT BARRIER FENCING

B

1.

DEPTH TO PROVIDE CONTINUED STABILITY

3.

PRE-CONSTRUCTION MEETING: COORDINATE AND CONDUCT AN ON-SITE MEETING WITH THE ALACHUA COUNTY FORESTER/LANDSCAPE INSPECTOR OR DESIGNATED COUNTY REPRESENTATIVE TO DISCUSS EXISTING REGULATED TREES AND PROTECTION METHODS. CONTACT: (352) 374-5243 EXT. 3503.

REVISIONS:

06 DEC 2021

NOTE:

EXISTING TREE PROTECTION: PROTECTIVE BARRIERS SHALL BE INSTALLED OUTSIDE THE PROTECTED AREA OF RETAINED TREES AND NATIVE VEGETATION TO PREVENT THE COMPACTION OF SOIL AND THE DESTRUCTION OR DAMAGE OF THE TREES. SEE DETAIL 1 & 2 / SHEET LS-1. PROTECTED TREES SHALL INCLUDE THOSE TREES THAT HAVE NOT BEEN PERMITTED NOR DESIGNATED FOR REMOVAL BY EITHER THE TERMS OF THE PERMIT OR APPROVED DEVELOPMENT ORDER. PROTECTIVE BARRIERS SHALL BE PLAINLY VISIBLE AND SHALL CREATE A CONTINUOUS BOUNDARY AROUND TREES OR VEGETATION CLUSTERS IN ORDER TO PREVENT ENCROACHMENT BY MACHINERY, VEHICLES, OR STORED MATERIALS. BARRIERS SHALL BE INSPECTED BY THE COUNTY FORESTER/LANDSCAPE INSPECTOR PRIOR TO PROCEEDING WITH SITE WORK. PROTECTIVE BARRIERS SHALL REMAIN IN PLACE AND INTACT UNTIL CONSTRUCTION IS COMPLETED. PRESERVE EACH REGULATED TREE AND ASSOCIATED NATIVE VEGETATION WITHIN THE AREA OF THE DRIPLINE IN ITS ORIGINAL LOCATION.

04 OCT 2021

80.63

80.13

NORTH

MATCHLINE SHEET LS-2

3'-0" HEIGHT BARRIER FENCING

2.

ISSUED DATE:

6' WF

TREE PRESERVATION AND REMOVAL NOTES

C

DEVELOPMENT PLAN REVIEW

D 80.87

SF

81.53

4' BARBED WIRE FENCE

1.

ISSUED FOR:

O

#

85.33

86.93

SF

16 15

21-048

PROJECT NO:

O

#

17

P-28

18

BUILDING #9

19

82.08

O

#

20

BUILDING #11

#

21

E

O

N02°45'30"E 1265.07'

82.86

P-27

83.70

D

81.20

SW 148TH DR

E

O

22

TYPICAL TREE PROTECTION DETAIL

2

SCALE: N.T.S.

SPECIALTY TREE PROTECTION DETAIL

C

CONTACT THE ALACHUA COUNTY FORESTER/LANDSCAPING INSPECTOR AT (352) 374-5243 EXT. 3503 FOR A TREE BARRICADE INSPECTION PRIOR TO COMMENCEMENT OF CONSTRUCTION. DO NOT STORE MATERIALS OR ALLOW ENCROACHMENT OF VEHICLES OR MACHINERY WITHIN TREE BARRIER AREA. NO BUILDING MATERIALS, MACHINERY OR HARMFUL CHEMICALS SHALL BE PLACED WITHIN PROTECTIVE BARRIERS, EXCEPT SHORT-DURATION PLACEMENTS OF CLEAN FILL SOIL THAT WILL NOT HARM THE TREE.

5.

NO GRADE CHANGES MAY OCCUR WITHIN TREE BARRIER AREA WITHOUT APPROVAL.

6.

NO ATTACHMENTS OR WIRES OTHER THAN THOSE OF A PROTECTIVE AND NON-DAMAGING NATURE MAY BE ATTACHED TO ANY TREE.

7.

LANDSCAPE PREPARATION IN THE UNDISTURBED AREA SHALL BE PROHIBITED UNLESS SPECIFICALLY APPROVED OTHERWISE BY THE COUNTY. LANDSCAPING SHALL BE LIMITED TO PLACEMENT OF SOD, MULCH, OR OTHER GROUND COVERS.

8.

TREE BARRIERS TO REMAIN IN PLACE UNTIL CONSTRUCTION IS COMPLETED.

TREE BARRIERS TO REMAIN IN PLACE UNTIL CONSTRUCTION IS COMPLETED.

07 MAR 2022 02 MAY 2022

SCALE: N.T.S.

SCALE:

0

20'

2

3

4

5

6

7

8

9

10

80'

SCALE: 1" = 40'

B

SHEET TITLE:

TREE PRESERVATION AND REMOVAL PLAN A SHEET NUMBER:

LS-1 1

40'


2

5

8

9

10

MATCHLINE SHEET LS-1

SF

84.90

80.63

6' WF

SF SF

84.56

P-30

UP

Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412

SF

4' WIRE FENCE

SF

48 46 85.00

SF 83.33

TB

TB

#

TB

SF

SF

TB

TB

TB

TB

TB

TB

E IBL SS CE TABLE AC NIC PIC

TYPICAL TREE BARRICADE - SEE SHEET LS-1, DETAIL 1

84.31

SF SF

106

85.67 WL

86.26

SF

WL

SF

D

SW

PL

3R

88.02

87.79

83.61

82.71

84.32

SF 86.76

for

HKP Development

SF

83.93

87.69

SF

SF

85.15

SF

X#

87.36 88.36

SEAL:

SF

88.21

O

SF

57

83.61

56

G

O

G

84.81

55

88.60

84.47

O

#

52

86.45

87.15

82.85

Alachua County, FL

SF

SW 148TH DR

90.94

SF

SPECIALTY TREE BARRICADE - SEE SHEET86.54 LS-1, DETAIL 2 EXISTING TREE TO REMAIN, TYP.

102

SF

100 101

98 97

83.09

86.28

SF

87.17

103

84.48

SF

99

H

SF

85.84

85.66

SF

96

#

51

EXISTING TREE CANOPY TO REMAIN, TYP.

85.79

O

BUILDING #8

#

45

86.27

86.06

83.79

O

89.44

85.73

BUILDING #10

#

90.55

H

SF

83.92

87.60

O

88.51

53 54

LAUREATE VILLAGE Phase 2, Unit 2

O

104 107

87.70 87.19

TB

105

E IBL SS CE TABLE AC NIC PIC

#

TB

LE

108 89.25

I

O

TAB

#

SF

LE TAB

NIC

WL

WL

4' WIRE FENCE

TB

N02°45'30"E 1265.07'

NIC PIC

PIC

41 42 43 44

84.53

UP

84.85

TB

40

PROJECT NAME:

SF

87.94

O

TB

TB

38

82.06

84.47

SF

TB

Certificate of Authorization No. LC26000575

81.20

TB

TB

39

I

TB

P-32

TB

SF

50

S02°45'46"W 1265.84' 82.93

P-31

#

O

87.92

49

SF

47

Site Planning

O

#

MATCHLINE SHEET LS-2

P-29

86.98

Landscape Architecture

J 4' BARBED WIRE FENCE

85.61

80.13

80.87

MANLEY DESIGN O

#

7

6

SF

85.33

J

4

3

BUILDING #9

1

SF

58 SF

91.05 X

88.39

O

87.05

#

59

87.40

SF

SF

SW 3RD PL

O

F

SF SF

SF

85.02

84.45

SF

0.6'W

4' BARBED WIRE FENCE

6' WF

SF O

87.69

88.37

SF

88.26

0.8'E

WL

91.22

E

SF

X

# 91.86

E

BUILDING #4

BUILDING #6

X

#

67

88.06

85.95

SF

X

#

86.15

SF O 86.17

86.55

O

BUILDING #1

SF

X

SF

#

F

87.28 X

SF

#

SF O

66 65

SF

86.78 88.76

SF

84.28 85.24

O

X

WL

#

64

88.27

SF

SF

21-048

PROJECT NO: CLIENT'S NO.:

SF

63

ISSUED FOR:

DEVELOPMENT PLAN REVIEW

ISSUED DATE:

04 OCT 2021

60 90.15

SF SF

SF

SF SF O SF

#

X

SF

84.76

C

SF

89.61

SF O

BUILDING #3

78

92.90

85.62

SF

71

88.55

SF

79 77

89.00

07 MAR 2022 02 MAY 2022

O

#

WL

90.93

SW 148TH TER

BUILDING #5

X

WL

WL

88.52

06 DEC 2021

SF

#

#

X

69 70

C

SF O

L

REVISIONS:

68

72

D

W

X

92.53

91.63

SW 147TH TER

D

BUILDING #2

61 62

O

BUILDING #7

92.74

WL

88.22

89.03

89.99

86.05

O

#

SCALE:

SF

89.53

89.77

75 91.49

76

O

O

O

O

O

O

O

O

O

O

O

O

O

9.7'

O

# 87.61

91.74 92.62

O

86.67

80 82

86

85

9.8'

S89°13'44"W 1001.67'

74

O

4' WIRE FENCE

5.8'

3' BARBED WIRE FENCE

90.16

3' BARBED WIRE FENCE 84

O

B

7.1'

X

88.16

NORTH

SF O

0.6'E 92.32

2.6'

SF

SF

91.96

O

4' WF

90.44

83

87

88

4' WIRE FENCE

90

89

90.68

90.68

SPECIALTY TREE BARRICADE - SEE SHEET LS-1, DETAIL 2

90.26

89.99

4' WF

81

90.34

95

93

6' WF SF

#

CRUSHED RECYCLED CONCRETE PATH - SEE DETAIL 5/LS-6.

94 92

X

89.13

73

91

0

86.68

20'

40'

80'

86.52

TR

SCALE: 1" = 40'

B

4' BARBED WIRE FENCE 87.01 90.34

90.67

SHEET TITLE:

TREE PRESERVATION AND REMOVAL PLAN

LEGEND

EXISTING TREES AND

75

VEGETATION TO REMAIN A

A SHEET NUMBER: 24 LA

1

EXISTING TREE TO BE REMOVED

LS-2 2

3

4

5

6

7

8

9

10


1

2

3

4

5

6

EXISTING REGULATED TREES AND REQUIRED MITIGATION

7

8

9

10

MANLEY DESIGN

EXISTING TREE INVENTORY

Landscape Architecture

Site Planning

Per Alachua County ULDC, Chapter 410, Article III. Defined Terms J

J

Regulated trees are 8" DBH and over or those trees required as part of a previous development order. Heritage tree size is 20" DBH and over for native tree species and 30" for nonnative trees, Laurel Oaks, and Water Oaks.

Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412

Mitigation per Alachua County ULDC, Article II., Sec. 406.13.b. Mitigation by replacement: Regulated trees eight inches and less than 20 inches DBH, except those trees listed below, shall be replaced at a ratio of one tree planted for every tree removed.

Certificate of Authorization No. LC26000575

Regulated trees greater than or equal to 20 inches DBH, other than trees listed below, shall be replaced with native trees with a cumulative diameter of stems greater than or equal to the diameter of the tree being replaced at the rates found in Table 406.13.1 I

PROJECT NAME:

I

No mitigation is required for abundant species such as Loblolly Pine, Slash Pine, and Sweetgum under 20 inches DBH, and Laurel Oaks and Water Oaks under 30 inches DBH, regardless of condition. Mitigation for trees greater than the 20 and 30 inch size thresholds stated above shall be at a ratio of one tree planted for each tree removed.

LAUREATE VILLAGE TND Phase 2, Unit 2

For those trees retained in excess of the minimum canopy retention requirements with impacts to the dripline described in 406.12(a)(5), replacement trees shall be required at half the rate in 406.13(b)(2), (3) and (4). Replacement trees shall be at least ten feet in height, two caliper inches and shall consist of native vegetation, indigenous to the area, and be Florida Grade No. 1 or better in quality according to the current, most recent edition of "Grades and Standards". Mitigation is based on information as provided within the project survey and direction provided by the Alachua County Forester/Landscape Inspector at the on-site review. Refer to Preliminary Tree Report and plan sheet Tree Charts for tree ratings provided by Forester/Inspector and associated tree mitigation requirements as discussed during the on site review.

H

H

Alachua County, FL

for

HKP Development G

G

SEAL:

F

F

E

E

PROJECT NO:

21-048

CLIENT'S NO.:

NOTE: THE PREVIOUSLY APPROVED PRELIMINARY DEVELOPMENT PLAN IDENTIFIED AND APPROVED PROPOSED BLOCKS AND STREETS WITHIN AREAS WITHIN THE DRIPLINE OF AND OTHERWISE IMPACING EXISTING LIVE OAKS 60" DBH AND LARGER. THEREFORE THE 60” DBH OR GREATER PROVISION OF ULDC 406.12 (SEE BELOW) DOES NOT APPLY TO THIS PROJECT. HOWEVER, CURRENT ALACHUA COUNTY TREE MITIGATION REQUIREMENTS DO APPLY FOR REMOVAL OF THESE AND OTHER TREES. THE ABOVE MITIGATION CALCULATIONS ARE PER CURRENT CODE REQUIREMENTS. “A TREE REMOVAL PERMIT AUTHORIZING THE REMOVAL OF HIGH QUALITY SPECIMEN TREES 60 INCHES DBH OR GREATER MAY ONLY BE ISSUED UPON DEMONSTRATION BY THE APPLICANT THAT THE DEVELOPMENT ACTIVITY CANNOT OCCUR IN ANY LOCATION ON THE SITE, OR THAT REMOVAL IS UNAVOIDABLE DUE TO SITE CONDITIONS AND DESIGN CONSIDERATIONS THAT MINIMIZE IMPACTS TO OTHER REGULATED RESOURCES.”

D

ISSUED FOR:

DEVELOPMENT PLAN REVIEW

ISSUED DATE:

04 OCT 2021

D

REVISIONS:

06 DEC 2021 07 MAR 2022 02 MAY 2022

C

C

PRESERVATION OF EXISTING TREE CANOPY Per Alachua County ULDC, Article II., Sec. 406.12A minimum of 5% of the tree canopy shown on the property's most recent aerial shall be retained. SCALE:

See Civil Sheet 'Tree Canopy Preservation Plan, TREE CANOPY TABLE' for calculations to support below:

B

NOT APPLICABLE

PHASE

EXISTING (AC)

REQUIRED (AC)

RETAINED (AC)

RETAINED % OF TOTAL

Phase 1, Unit 1 & 2

19.87-AC *

0.00-AC *

4.51-AC *

22.70%

Phase 1, Unit 3

23.14-AC *

0.00-AC *

3.27-AC *

14.13%

Phase 2, Unit 1 & 2

2.60-AC *

0.00-AC *

1.92-AC *

73.85%

Future

20.81-AC *

3.33-AC *

TBD

TBD

SHEET TITLE:

TOTALS

66.52-AC *

3.33-AC *

9.70-AC

14.58%

TREE PRESERVATION AND REMOVAL CHART

B

NOTE: THE EXISTING TOTAL WAS ESTABLISHED BY THE APPROVED PRELIMINARY DEVELOPMENT PLAN (PDP).

A

A SHEET NUMBER:

LS-3 1

2

3

4

5

6

7

8

9

10


1

2

4

3

5

7

6

8

9

10

MANLEY DESIGN

86.41

88.40

86.82

D

UP

2 - ML

3 - LIM

3 - PP

TREES SET BACK DUE TO OVERHEAD UTILITY 89.73

H

3 - QM 3 - LIM

TB

36

85.99

OW

85.92

#

TB

PROPOSED SIGN - SEE ARCHITECTURAL 87.17 PLANS

PROPOSED MAINTENANCE PATH - SEE CIVIL PLANS

TB

#

88.34

2 - AR 1 - QVS

UP

D OW

83.27

82.15

TOP=82.08 N. INV=76.88 E. INV=76.33 W. INV=76.38 81.40 81.89 81.99 82.02

24" RCP

82.03

82.21

OW

D

80.71 81.17 81.21 81.39 81.47 81.40

82.77

5' CW ASPHALT

DRMP TEST HOLE # EH-3 ELEV=80.77

78.59 78.94 79.07 79.12

D

D

OW

OW

UP

81.97

TOP=78.85 N. INV=69.80 E. INV=69.75

D

5' CW

79.24

SOD DISTURBED AREAS, TYP.

76.15 76.58 76.75 76.82 76.93 76.75

D OW

UP

LAUREATE VILLAGE TND Phase 2, Unit 2

OW

79.35

3 - PO 6 - ML 82.08

I

EP

8" PVC

3 - PP 3 - LIM PROPOSED MAINTENANCE PATH - SEE CIVIL PLANS 47 - IS 3 - PT 22 - MC 27 - IS 5 - QV

SDO

UTILITY ESMT 13 ORB 2508, PG 1284

4' WF

3 - PP

H

2 - TDS 58 - IS

1 - TDS

3 - PT 81 - MC

80.35 80.11

Alachua County, FL 73.66

for

22 - IS 39 - TF

24 - MC 32 - SBA 25 - SBA 70 - MC

SPECIALTY TREE BARRICADE - SEE SHEET LS-1, DETAIL 2

PROJECT NAME: SDO

D

83.23

ARTERIAL STREET BUFFER

85.01

D OW

83.10

79.27

39 - TF 60 - IS

82.33

HKP Development G

SF

1 - QVS

33 81.76 83.18

87.90

SW 1ST PL

SF

W

9 - MC 2 - QVS

L

SEE CIVIL PLANS FOR GRASSING OF STORMWATER SWALES AND FACILITIES, TYP.

1 - QV 4 - QV

4 - ID

13 - TF

144 - TF

82.32

#

TB

9 - MC

126

TB

2 - TDS

128

5 - SP

81.92

TB

83.59

37 - SBA 65 - MC

2 - ARF

127

2 - QVS

E

50 - TF 80.11

22 - SBA 33 - MC

81.13

80.07

79.36

O

2 - QV

28 - MC 83 - TF

SF

SW 147TH TER

2 - AR

83.63

37 - SBA

F

O

27

68 - IS 3 - AR

31 - SBA

3 - QV 3 - UA

2 - QV

WL

TB

6 - MC

40 - SBA 20 - TF

74.79

67 - SBA

86.31

28

26

1 - QVS

81.32

SF

20 - SBA

TB

#

19 - MC 68 - IS

80.48

SF

85.35

SF

2 - ID

SF

3 - TDS

TB

TYPICAL TREE BARRICADE 85.79 SEE SHEET LS-1, DETAIL 1

SEAL:

16 - MC 12 - IS

O

125

79.96

SF

TB

#

32

SF

TB

IRRIGATION VALVE

F

D OW

81.45

O

30

85.10

79.82

2 - QV

4 - ARF

TB

29 31 IRRIGATION CONTROL BOX

D OW

81.62

24" RCP 82.13

80.38

81.99

88.29

PROPOSED LIGHT, TYP.

11 - IS 13 - SBA

G

24" RCP

82.99 83.04

1 - QV

EXISTING TREE TO REMAIN, TYP.

81.99

82.53

1 - QV

122

123

87.77

121

2' CURB & GUTTER (TYP)

82.16

O

3 - TDS 88.13 14 - MC

TB

34

CRUSHED RECYCLED CONCRETE PATHS - SEE DETAIL 5/LS-6.

3 - QM

84.28 84.76 84.85 84.97

24" RCP

124 4' WIRE FENCE

83.28

NEWBERRY ROAD / SR 26

85.30 85.73

85.97

18" RCP

18" RCP

D

86.30

TOP=85.93 N. INV=80.98 E. INV=80.88 W. INV=80.83

85.09

82.17 82.67 82.54

Certificate of Authorization No. LC26000575

79.72

81.65

O

TB

35

85.86

86.90 86.58 87.04 87.20 86.78 T 87.23 87.11 87.29 88.46 87.59 87.04

OWBUFFER, CANOPY OW 88.86 ARTERIAL STREET

4 - PP

1 - ML

24" RCP

D

88 88 .3 7 .41

87.97

D

87.00

D

88.43 88.62 88.69

86.47

83.55 84.04 83.85

EP 79.14

SF

OW

2 - ML

89.83

87.77

8" CONC CURB (TYP) 85.34 85.81 85.65

81.5 82.13 82.25

81.13

ASPHALT

SF

37

D

OW

UP

89.56 2 - PO

89.20

88.03 87.46

W NEWBERRY ROAD (STATE ROAD 26)

DRMP TEST HOLE # VVH-2 ELEV=80.71 8

DRMP TEST HOLE # EH-2 DRMP TEST ELEV=80.73 HOLE # VVH-3 ELEV=80.63

Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412

EP

SF

89.73

EP

EP

SF

OW

24" RCP

D

D

89.55

89.58

0

DRMP TEST HOLE # VVH-1 ELEV=80.50

T

G OW5' CW

G OW

G OW

G OW

SF

5' CW

OW

89.34

D

88.22

88.0

86.68 87.12 86.89

OW5' CW

Site Planning

J

SF

89.31

89.25

UP

D

SDO 89.15

G OW

G

120

114 - IS 63 - SBA

E

80.34 78.03

SF

88.63 89.23

OW

5' CW 2' CURB & GUTTER (TYP)

SW 147TH DR

88.65

89.03 89.41

88.79

88.28 88.22

TOP=88.98 N. INV=83.98 E. INV=82.88 W. INV=82.83

ASPHALT

2' CURB & GUTTER (TYP)

88.82

87.11 86.94 .22 8 87 87.06 87.32 87.3 6 .9 86.87 6 8

85.39

EP

89.30

57

87.72

88.30

88.

85.58

OW

EP

89.18

87.97

88.70

.03

86.07

89.82

89.66

88

86.90 86.94 86.96

86.37

89.43

88.96

86.98

87.47

87.24 87.14

90.31

89.30

88.00

88.03

UP

89.91

11

12

88.39

1 .4 88 99 . 88

I

14

90.70

2' CURB & GUTTER (TYP)

90.33

13

88.77

EP

OW

90.34

90.00

18" RCP

89.78

8 899.00 .0 1

OW

ASPHALT

89.47

OW

G

EP

EP

EP

X

8" PVC

OW

G

DRMP TEST HOLE # EH-1 ELEV=80.75 G

SF

OW

5' CW

X

81.50

OW

5' CW

G

114

SF

X

G

G

3' WF

115

SF

G

GOW

GOW

5' CW 2' CURB & GUTTER (TYP)

X FOBG

X G

X

X

FOB TV

TOP=85.87 S. INV=81.37

TOP=81.91 S. INV=77.51

SF

X

TOP=88.96 S. INV=84.26

113

SF

CONC APRON

3' WF

FIBER OPTIC CABLE MARKER 3' WF

CBW

118

117

116

129

SF

J

6' VF

Landscape Architecture

6' VF

119

SF

3' WF

3' WF

CBW

78.95

25

5 - TC

16 15

3 - LT

79.62

79.04

SF

07 MAR 2022 02 MAY 2022

SF

2 - UA

C

72 - IS 86.93

7 - PM PROPOSED HYDRANT, TYP. 4 - PM

60 - MC 81.53

MATCHLINE SHEET LS-4 84.90

2 - QV 2 - LT

SF SF SF

82.08

#

85.33

15 - PM

04 OCT 2021 06 DEC 2021

2 - UA

85.61

37 - TF

45 - TF 38 - MC 8 - IS

2 - QV

36 - IS

86.98

MATCHLINE SHEET LS-5

26 - SBA SEE CIVIL

80.63

17

15 - PM

1 - LT

3 - QVS 108 - SBA

O

BUILDING #9

18

11 - PM

ISSUED DATE: REVISIONS:

80.13

C

A/C UNITS- SEE ARCHITECTURAL PLANS, TYP.

1 - LT

SF

19

#

20

82.86

DEVELOPMENT PLAN REVIEW

D

81.20

SW 148TH DR

21

9 - ID 8 - DTV

ISSUED FOR:

O

PROPOSED SCREEN WALL AND TRELLISSEE ARCHITECTURAL PLANS, TYP.

8 - ID 8 - DTV 2 - QV

82.58

BUILDING #11

5 - TC

83.70

PARKING 'D'

22

2 - QV

82.13

O

1 - TD

SF

1 - SP

81.27

#

2 - UA

23

CLIENT'S NO.:

SF

2 - TD

5 - LT

21-048

PROJECT NO:

88 - TF

80.87

81.07

30 - SBA

81.45

SCALE:

SF

5 - TD

2 - TD

SF

SW 2ND LN

40 - MC 32 - TF

O

PROPOSED TRANSFORMER, TYP.

24

D

29 - SBA

DESIGN OF THIS PARCEL BY OTHERS

PROPOSED 6' VINYL FENCE, SEE CIVIL PLANS

SF

17 - TF 3 - AR 27 - MC 4 - PT

#

81.91

20 - TF

NORTH 0

LEGEND B

24 LA

EXISTING TREES AND VEGETATION TO REMAIN

LANDSCAPE PLAN PROPOSED TREE

A

TRANSFORMER CLEAR ZONE AND

SHEET NUMBER:

ACCESS DOOR LOCATION

LS-4 2

3

4

5

6

7

8

80'

SHEET TITLE:

A

1

40'

SCALE: 1" = 40'

B TRANSFORMERS: HEDGE PLANTINGS HAVE BEEN ADDED AROUND TRANSFORMERS AND MECHANICAL EQUIPMENT AS POSSIBLE TO SCREEN FROM ADJACENT ROADWAYS AND USE AREAS. PLANTINGS MUST ADHERE TO CLAY ELECTRIC'S STANDARD OFFSETS AROUND TRANSFORMERS, WHICH REQUIRES A CLEARANCE OF 4' AROUND ALL SIDES AND A 10' OR FULL CLEARANCE ON THE ACCESS DOOR/FRONT FACE. THESE PLANS ASSUMES TRANSFORMERS FACE ADJACENT ROADWAYS OR PAVED AREAS FROM WHICH MAINTENANCE TRUCKS WILL ACCESS. AS SUCH, IT HAS NOT BEEN POSSIBLE TO SURROUND TRANSFORMERS WITH PLANTINGS NOR TO SCREEN FROM ALL VIEWS FROM ADJACENT ROADWAYS AND PARKING. CONTRACTOR TO FIELD ADJUST PLANTINGS PER ACTUAL TRANSFORMER ACCESS DOOR LOCATIONS DURING CONSTRUCTION AS NEEDED TO PROVIDE REQUIRED CLEARANCES, IF ACCESS DOORS AND/OR TRANSFORMER LOCATIONS ARE INSTALLED DIFFERENTLY THAN PLANS INDICATE.

20'

9

10


87.92

49

12 - PM

85.00

6 - QM

4 - TD

TYPICAL TREE BARRICADE - SEE SHEET LS-1, DETAIL 1

1 - QV 2 - UA

50

39

12 - ID

84.47

TB

SF

84.53

83.79

86.76

SW

2 - QV

2 - QSL

85.15

6 - TC 1 - SP

14 - DTV

87.36

2 - UA

87.40

#

5 - ID

X X

5 - TC

91.22

2 - LT 10 - ID

4 - LP

1 - LT

1 - UA

1 - LT

15 - PM

87.28

89.00

1 - SP88.55

14 - PM 14 - PM

15 - PM

1 - QM

89.99

3 - QM 3 - QV

83.61

07 MAR 2022 02 MAY 2022

84.76

C

86.05 89.13

91.96

SF

SCALE:

75

90.16

92.32

84

91.49 88.16

76

85

PROPOSED 6' VINYL FENCE, SEE CIVIL PLANS

O

O

O

O

O

O

O

O 4' WF

92.62

91.74

O

74

80 82

86

83

87

88

89.99

90.34

90

89

90.68

90.68

SPECIALTY TREE BARRICADE - SEE SHEET LS-1, DETAIL 2

90.26

4' WF

81

94 92

X

#

85.62

89.77

CRUSHED RECYCLED CONCRETE PATH - SEE DETAIL 5/LS-6.

04 OCT 2021 06 DEC 2021

SF

6 - LT

3 - QV 4 - QM

1 - LT 7 - UA

89.61

SOD DISTURBED AREAS, TYP.

ISSUED DATE: REVISIONS:

73

B

O 1 - QSL

14 - PM

PROPOSED 6' VINYL FENCE, SEE CIVIL PLANS

SF O SF

5 - ID

88.52

78

1 - LT 92.90

DEVELOPMENT PLAN REVIEW

SF

5 - TC

ISSUED FOR:

D

5 - ID

SF O

1 - QV

5 - TC

SF O

X

79 77

CLIENT'S NO.:

14 - ID

4 - LP

21-048

PROJECT NO:

SF

15 - PM

SW 147TH TER

15 - PM

SF

15 - PM

BUILDING #2

#

9 - ID 5 - TC

71

87.61

17 - DTV 1 - QV

4 - DTV

3 - LT

WL #

2 - QV

92.53

4 - QM

90.93

3 - LT 15 - PM 15 - PM

BUILDING #3

X

68

2 - LT 1 - LT

SW 148TH TER

91.63

7 - IVS

BUILDING #5

1 - LT

90.15

7 - IVS

PARKING 'C'

61 62

88.22

89.03

PARKING 'A'

1 - LT

PARKING 'B'

SF

12 - PM 1 - QV

BUILDING #7

92.74

2 - QV

2 - QV

1 - LT

2 - QV

2 - QV

WL

60

7 - IVS 2 - QV

SF

88.27

2 - QV

89.53

84.28 85.24

88.76

64

69 70

E

SF

86.78

7 - IVS 2 - QM

86.67

SF

13 - PM 1 - QSL

65

63

SF

O

5 - TC

SF

87.69

3 - SP

12 - PM

3 - PM

1 - LT

88.26

88.06 88.37

14 - PM

F 85.95

SF

X #

A/C UNITS- SEE ARCHITECTURAL PLANS, TYP.

BUILDING #4

HYDRANT- SEE CIVIL PLANS, TYP.

BUILDING #6

# 66

2 - QV

SF

BUILDING #1

6 - LT 86.15

5 - LP 7 - IVS 1 - QV 2 - LT

PROPOSED SCREEN WALL AND TRELLISSEE ARCHITECTURAL PLANS, TYP. 91.86

67

14 - PM

1 - QV

PARKING 'E'

5 - SP

O

2 - SP 86.55

4 - QML 5 - TC

82.71

SF 1 - SP

3 - QM

1 - SP

C

SEAL:

7 - ID 1 - UA

F

72

7 - PM

19 - DTV

5 - QSL 2 - SP

SF

88.39

2 - UA

SF

PROPOSED LIGHT, TYP.

87.05

2 - ARF 1 - QV

1 - QV

G

O

59

SW 3RD PL

HKP Development

1 - QV

58

D

3 - ID 5 - TC

88.36

2 - QV 1 - UA

for

2 - LIM 92 - PM 1 - LIM

87.69

8 - ID

91.05

SF

6 - QV

SF

SOD DISTURBED AREAS, TYP.

Alachua County, FL

SOD

83.93

88.21

E

3 - QV

2 - UA

88.02

87.79

D 3R

PL

83.61

88.60

H

84.47

SF

86.45

87.15

82.85

9 - ID

PROPOSED 6' VINYL FENCE, SEE CIVIL PLANS

SF SF

SPECIALTY TREE BARRICADE - SEE SHEET86.54 LS-1, DETAIL 2 EXISTING TREE TO REMAIN, TYP.

102

SF

83.09

SF

103

84.48

100 101

98 97

84.81

57

99

O

7 - IVS

5 - ID 6 - TC

56

85.84

87.17

1 - QVS 3 - LT 5 - LP 7 - IVS

SOD DISTURBED AREAS, TYP.

85.66 86.28

96

55

2 - LT

85.79

84.45

2 - UA

2 - UA

86.27

86.06

SF

52

83.92 85.73

SW 148TH DR

90.94

SF

88.51

BUILDING #10

PARKING 'D'

BUILDING #8

14 - PM

#

51

2 - QV

PROPOSED MAINTENANCE PATH - SEE CIVIL PLANS 2 - QSL 1 - QV

86.17

#

#

16 - PM

O

86.26

87.60

LAUREATE VILLAGE TND Phase 2, Unit 2

3 - QVS

6 - QM

O

H

106

WL

14 - PM

3 - QV

85.67

90.55

45

TB

2 - UA

TB

4 - LT

87.19

I

84.31

104 107

87.70

15 - PM

89.44

105 E IBL SS LE CE AC NIC TAB PIC

14 - PM

PROPOSED TRANSFORMER,TYP.

TB

2 - UA

BLE SSI LE CE AC NIC TAB PIC

89.25

PROJECT NAME:

SF

LE

TB

TAB

LE TAB

WL

4' WIRE FENCE

G

SF

NIC PIC

NIC PIC

108

3 - QM

53 54

Certificate of Authorization No. LC26000575

84.85

41 42 43 44

I

Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412

O

87.94

40

83.33

TB

1 - QVS

38

TB

TB

13 - ID

Site Planning

J

82.06

16 - ID

SF

PROPOSED PICNIC PAVILION - SEE ARCHITECTURAL PLANS.

Landscape Architecture

84.32

47

36 - IS 20 - TF SEE CIVIL 26 - MC PLANS FOR 23 - SBA 75 - TF GRASSING OF 1 - QVS 18 - SBA STORMWATER 53 - IS SWALES AND 4 - TDS 95 - IS FACILITIES, 75 - TF TYP. 138 - MC 83 - TF 109 - IS

84.56

MANLEY DESIGN

81.20

48 46

26 - SBA

O

1 - LT 2 - UA

38 - MC 8 - IS

10

82.93

4' WIRE FENCE

9

85.02

J

86.98

2 - UA

85.61

8

MATCHLINE SHEET LS-4 MATCHLINE SHEET LS-5

2 - QV 2 - LT

7

6

SF

5

SF

4

3

SF

BUILDING #9

2

#

1

95

93

6' WF 86.68

91 86.52

TR 87.01 90.67

90.44

0

NORTH

90.34

40'

80'

SCALE: 1" = 40'

B

LEGEND

20'

SHEET TITLE: 24 LA

EXISTING TREES AND

LANDSCAPE PLAN

VEGETATION TO REMAIN TRANSFORMERS: HEDGE PLANTINGS HAVE BEEN ADDED AROUND TRANSFORMERS AND MECHANICAL EQUIPMENT AS POSSIBLE TO SCREEN FROM ADJACENT ROADWAYS AND USE AREAS. PLANTINGS MUST ADHERE TO CLAY ELECTRIC'S STANDARD OFFSETS AROUND TRANSFORMERS, WHICH REQUIRES A CLEARANCE OF 4' AROUND ALL SIDES AND A 10' OR FULL CLEARANCE ON THE ACCESS DOOR/FRONT FACE. THESE PLANS ASSUMES TRANSFORMERS FACE ADJACENT ROADWAYS OR PAVED AREAS FROM WHICH MAINTENANCE TRUCKS WILL ACCESS. AS SUCH, IT HAS NOT BEEN POSSIBLE TO SURROUND TRANSFORMERS WITH PLANTINGS NOR TO SCREEN FROM ALL VIEWS FROM ADJACENT ROADWAYS AND PARKING. CONTRACTOR TO FIELD ADJUST PLANTINGS PER ACTUAL TRANSFORMER ACCESS DOOR LOCATIONS DURING CONSTRUCTION AS NEEDED TO PROVIDE REQUIRED CLEARANCES, IF ACCESS DOORS AND/OR TRANSFORMER LOCATIONS ARE INSTALLED DIFFERENTLY THAN PLANS INDICATE.

A

PROPOSED TREE A SHEET NUMBER:

TRANSFORMER CLEAR ZONE AND ACCESS DOOR LOCATION

1

2

3

4

5

6

7

8

9

10

LS-5


1

2

4

3

5

7

6

8

9

10

MANLEY DESIGN Landscape Architecture

J

J

LANDSCAPE NOTES

PLANT SCHEDULE TREES AR

QTY 10

BOTANICAL NAME Acer rubrum

COMMON NAME Red Maple

SIZE 7 gal., 7` ht. x 24" sprd., 3/4" cal.

SPACING As shown

ARF

8

Acer rubrum `Florida Flame`

Florida Flame Red Maple

30 gal., 11` ht. x 48" sprd., 2" cal.

As shown

NOTES

1.

PRE-CONSTRUCTION MEETING: COORDINATE AND CONDUCT AN ON-SITE MEETING WITH THE ALACHUA COUNTY FORESTER/LANDSCAPE INSPECTOR OR DESIGNATED COUNTY REPRESENTATIVE TO DISCUSS EXISTING REGULATED TREES AND PROTECTION METHODS. CONTACT: (352) 374-5243 EXT. 3503.

2.

EXISTING UTILITIES: LOCATE ALL UTILITIES PRIOR TO COMMENCEMENT OF WORK. CALL SUNSHINE STATE ONE CALL - SEE LOGO BELOW.

3.

INVASIVE SPECIES: REMOVE INVASIVE, NONNATIVE PLANT SPECIES AS LISTED ON THE FLORIDA PROHIBITED AQUATIC PLANTS LIST OR THE FLORIDA NOXIOUS WEED LIST FROM THE SITE PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. ALL HERBICIDE APPLICATIONS TO CONTROL INVASIVE, NONNATIVE PLANTS IN WETLAND OR UPLAND SET-ASIDE AREAS, INCLUDING BUFFERS, SHALL BE APPLIED BY A CONTRACTOR LICENSED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES, DIVISION OF AGRICULTURAL ENVIRONMENTAL SERVICES, WITH A CURRENT CERTIFICATION IN NATURAL AREAS WEED MANAGEMENT.

LIM

12

Lagerstroemia indica x faurei `Muskogee`

Muskogee Crape Myrtle

30 gal., 10` ht. x 48" sprd., 2" cal.

As shown

Multi-trunk, five canes minimum

LT

55

Liriodendron tulipifera

Tulip Tree

30 gal., 11` ht. x 48" sprd., 2" cal.

As shown

ML

11

Magnolia grandiflora 'Little Gem'

Little Gem Dwarf Southern Magnolia

30 gal., 11` ht. x 48" sprd., 2" cal.

As shown

PP

13

Pinus palustris

Longleaf Pine

30 gal., 10` ht. x 42" sprd., 2" cal.

As shown

PT

10

Pinus taeda

Loblolly Pine

7 gal., 6` ht. x 24" sprd., 3/4" cal.

As shown

PO

5

Platanus occidentalis

American Sycamore

30 gal., 11` ht. x 48" sprd., 2" cal.

As shown

QML

4

Quercus michauxii

Swamp Chestnut Oak

30 gal., 11` ht. x 48" sprd., 2" cal.

As shown

QM

38

Quercus michauxii

Swamp Chestnut Oak

7 gal., 6` ht. x 24" sprd., 3/4" cal.

As shown

QSL

11

Quercus shumardii

Shumard Oak

30 gal., 11` ht. x 48" sprd., 2" cal.

As shown

QV

76

Quercus virginiana

Southern Live Oak

30 gal., 11` ht. x 48" sprd., 2" cal.

As shown

QVS

16

Quercus virginiana

Southern Live Oak

7 gal., 7` ht. x 24" sprd., 3/4" cal.

As shown

TD

14

Taxodium distichum

Bald Cypress

30 gal., 10` ht. x 48" sprd., 2" cal.

As shown

8.

PLANT MATERIAL, GENERAL: ALL PLANT MATERIALS SHALL MEET 'FLORIDA NUMBER 1' REQUIREMENTS AS PER THE MOST CURRENT EDITION OF 'FLORIDA GRADES AND STANDARDS FOR NURSERY PLANTS', FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES.

TDS

15

Taxodium distichum

Bald Cypress

7 gal., 5` ht. x 20" sprd., 3/4" cal.

As shown

9.

UA

37

Ulmus alata

Winged Elm

30 gal., 11` ht. x 48" sprd., 2" cal.

As shown

PALMS SP

QTY 22

BOTANICAL NAME Sabal palmetto

COMMON NAME Cabbage Palmetto

SIZE 16` C.T., 12" min. cal. at 4.5` above grade

SPACING As shown

NOTES Regenerated, minimum four fronds

PROPOSED TREES: TREES PROPOSED ALONG STREETS, WITHIN PAVING, OR IN PARKING LOT ISLANDS SHALL BE A MINIMUM OF TEN FEET TALL, HAVE A MINIMUM TRUNK CALIPER OF TWO INCHES, AND BE IN 30-GALLON MINIMUM CONTAINER. TREES PROPOSED IN STORMWATER FACILITIES OR ELSEWHERE SHALL BE A MINIMUM OF FOUR FEET TALL, HAVE A MINIMUM TRUNK CALIPER OF 3/4 INCHES, AND BE IN 7-GALLON MINIMUM CONTAINERS. NEW TREES LOCATED OUTSIDE OF LARGER PLANTING AREAS/WITHIN TURF AREAS TO HAVE 6" OF PLASTIC DRAIN TUBING INSTALLED AROUND THE BASE OF THEIR TRUNK TO PROTECT FROM MOWER AND STRING TRIMMER IMPACTS.

SHRUBS DTV

QTY 70

BOTANICAL NAME Dianella tasmanica `Variegata`

COMMON NAME Variegated Flax Lily

SIZE 3 gal., 24" ht. x 18" sprd.

SPACING 24" o.c.

NOTES Full

ID

144

Ilex cornuta `Dwarf Burford`

Dwarf Burford Holly

3 gal., 24" ht. x 18" sprd.

30" o.c.

IVS

49

Ilex vomitoria 'Schillings Dwarf'

Schillings Dwarf Yaupon Holly

3 gal., 24" ht. x 18" sprd.

30" o.c.

LP

18

Loropetalum chinense rubrum `Plum Delight`

Plum Delight Loropetalum

3 gal., 24" ht. x 18" sprd.

30" o.c.

PM

451

Podocarpus macrophyllus

Podocarpus

3 gal., 24" ht. x 9" sprd.

30" o.c.

VINES TC

QTY 57

BOTANICAL NAME Trachelospermum jasminoides `Confederate`

COMMON NAME Confederate Jasmine

SIZE 3 gal., 24" ht. x 12" sprd.

SPACING 30" o.c.

NOTES Remove staking and train to trellis

SHRUB AREAS IS

QTY 860

BOTANICAL NAME Ilex vomitoria 'Schillings Dwarf'

COMMON NAME Schillings Dwarf Yaupon Holly

CONT 3 gal., 24" ht. x 18" sprd., 36" o.c.

FIELD2

FIELD3

MC

725

Muhlenbergia capillaris

Pink Muhly Grass

3 gal., 24" ht. x 18" sprd., 42" o.c.

SBA

621

Spartina bakeri

Sand Cordgrass

3 gal., 24" ht. x 18" sprd., 42" o.c.

TF

860

Tripsacum dactyloides

Fakahatchee Grass

3 gal., 24" ht. x 18" sprd., 42" o.c.

SOD/SEED SOD

QTY 8,688,447

BOTANICAL NAME Paspalum notatum `Argentine`

COMMON NAME Argentine Bahia Grass

SIZE sod

I

H

NOTE: 1. ENSURE PLANTING PIT DRAINS WELL PRIOR TO INSTALLATION. 2. REMOVE TREE FROM CONTAINER OR REMOVE UPPER 1/3 OF BURLAP AND WIRE MESH FOR B&B TREES. 3. SLICE ROOTBALL VERTICALLY ON OUTSIDE EDGES OF AND AROUND ROOTBALL. 4. TREE TO BE PLUMB. STAKE TREE IF NEEDED. SUBMIT TREE STAKING DETAILS AND LAYOUT FOR APPROVAL.

G

6" PLASTIC DRAIN TUBING IF TREE LOCATED OUTSIDE OF LARGER PLANTING AREA/IN TURF TOP OF ROOTBALL 1-2" ABOVE FINISH GRADE MULCH, 3" THICKNESS TYPICAL AND ONLY 1" OVER ROOTBALL 3" - 6" SOIL BERM TO OUTSIDE OF ROOTBALL F

4.

ON-SITE LITTER REMOVAL: REMOVE ALL EXISTING LITTER AND DEBRIS VISIBLE ON THE PROJECT SITE.

5.

PLANTING PREPARATION: REMOVE ALL CONSTRUCTION DEBRIS, LIMEROCK, GRAVEL, ROAD BEDDING, LITTER, AND OTHER ITEMS POTENTIALLY DAMAGING TO PLANT GROWTH WITHIN PROPOSED LANDSCAPE AND TURF AREAS PRIOR TO PLANTING. MAINTAIN EXISTING GRADES UNLESS OTHERWISE APPROVED BY THE OWNER'S REPRESENTATIVE. IF FILL IS REQUIRED, USE A CLEAN, SANDY LOAM WITH pH 5.5-6.5 AND EXCAVATED FROM LOCAL SOURCES AND DEEP PITS SUCH THAT IT IS FREE OF WEEDS, SEEDS, LITTER, TOXINS, AND OTHER ITEMS HARMFUL TO PLANTINGS.

6.

PRUNING: IF TREE OR ROOT PRUNING IS REQUIRED, THESE ACTIVITIES SHALL BE PERFORMED BY AN ARBORIST CERTIFIED BY THE INTERNATIONAL SOCIETY OF ARBORICULTURE (ISA). TREE PRUNING SHALL BE DONE IN ACCORDANCE WITH THE MOST CURRENT VERSION OF THE AMERICAN NATIONAL STANDARD FOR TREE CARE OPERATIONS "TREE. SHRUB AND OTHER WOODY PLANT MAINTENANCE" (ANSI 300) AND "PRUNING. TRIMMING. REPAIRING. MAINTAINING, AND REMOVING TREES. AND CUTTING BRUSH—SAFETY REQUIREMENTS" (ANSI Z133). NO MORE THAN 25 PERCENT OF THE CROWN SHOULD BE REMOVED AT ONE TIME. ON YOUNG TREES, LIMB REMOVAL SHALL LEAVE NO MORE THAN 33 PERCENT OF THE TRUNK BARE OF BRANCHES.

7.

MINIMUM PLANTING AREA: A MINIMUM PERVIOUS AREA OF 200 SF AND MINIMUM PLANTING AREA OF 140 SF SHALL BE PROVIDED FOR CANOPY TREES WITHIN PARKING AREAS. A MINIMUM PLANTING AREA OF 200 SF SHALL BE PROVIDED FOR CANOPY TREES OUTSIDE OF PARKING AREAS. A MINIMUM PERVIOUS AREA OF 120 SF AND MINIMUM PLANTING AREA OF 90 SF SHALL BE PROVIDED FOR UNDERSTORY TREES WITHIN PARKING AREAS. A MINIMUM PLANTING AREA OF 120 SF SHALL BE PROVIDED FOR UNDERSTORY TREES OUTSIDE OF PARKING AREAS. PLANTING AREAS SHOULD BE FREE FROM COMPACTED MATERIAL TO A DEPTH OF 18-INCHES, MINIMUM.

10.

NEW TREE STAKING: IF NECESSARY TO MAINTAIN TREES PLUMB, TREES SHALL BE STAKED WITH BIODEGRADABLE STAKING MATERIALS.

11.

PROPOSED SHRUBS: PROPOSED SHRUBS SHALL BE A MINIMUM OF TWO FEET TALL AND BE IN 3-GALLON MINIMUM CONTAINERS.

12.

SOD: ALL UNPAVED AND DISTURBED AREAS OUTSIDE OF PROPOSED TREE, SHRUB, AND GROUNDCOVER PLANTINGS SHALL BE SODDED. SEE CIVIL PLANS FOR SODDING INFORMATION FOR STORMWATER FACILITIES. SOD SHALL BE SAND-GROWN, STRONGLY ROOTED, WITHOUT SYNTHETIC STABILIZING MATERIALS, FREE OF PESTS, AND CERTIFIED FREE OF NOXIOUS WEEDS BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES, DIVISION OF PLANT INDUSTRY.

LOOSEN SIDE SLOPES OF PLANTING PIT

EQUAL

TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. ROOTBALL SITS ON BOTTOM OF PLANTING PIT

MULCHING: THREE INCHES OF MULCH, SETTLED, SHOULD COVER TREE RING PLANTING AREAS AND ALL SHRUB AND GROUNDCOVER PLANTING AREAS. MULCH SHOULD BE NO DEEPER THAN ONE INCH OVER THE TOP OF TREE ROOTBALLS. USE PINESTRAW MULCH IN ALL AREAS. MULCH TO BE FREE OF DEBRIS, STICKS, AND CONES. NO PLASTIC OR NON-BIODEGRADABLE WEED CLOTH OR SURFACE COVERS TO BE USED.

14.

IRRIGATION: A TEMPORARY AUTOMATIC IRRIGATION SYSTEM IS REQUIRED FOR ALL NEW REQUIRED LANDSCAPING INSTALLED [407.46(A)]. SEE CIVIL PLANS FOR IRRIGATION METER/POINT OF CONNECTION TO POTABLE WATER. TEMPORARY IRRIGATION SYSTEMS MUST BE REMOVED ONCE THE PLANTS ARE ESTABLISHED OR WITHIN TWO YEARS, WHICHEVER OCCURS FIRST. PRIOR TO THE INSTALLATION OF A NEW PERMANENT IRRIGATION SYSTEM OR SUBSTANTIAL MODIFICATION TO AN EXISTING SYSTEM, AN IRRIGATION PLAN MUST BE SUBMITTED TO AND APPROVED BY THE ALACHUA COUNTY ENVIRONMENTAL PROTECTION DEPARTMENT THROUGH THE ONLINE ALACHUA COUNTY IRRIGATION PROFESSIONAL PORTAL. THE IRRIGATION SYSTEM SHALL COMPLY WITH THE LANDSCAPE IRRIGATION DESIGN AND MAINTENANCE STANDARDS FOUND IN ARTICLE II OF PART II, TITLE 7, CHAPTER 79 OF THE ALACHUA COUNTY CODE, WHICH, AMONG ADDITIONAL DESIGN STANDARDS, REQUIRES THE FOLLOWING. FOR MORE INFORMATION, CONTACT THE ALACHUA COUNTY ENVIRONMENTAL PROTECTION DEPARTMENT AT 352-264-6800.

EQUAL

2 X ROOTBALL WIDTH

· · · SPACING

15.

NOTES Sand grown and weed free

PLANTING DETAIL 1 TREE SCALE: N.T.S

16.

Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412 Certificate of Authorization No. LC26000575

PROJECT NAME:

I

LAUREATE VILLAGE TND Phase 2, Unit 2 H

Alachua County, FL

for

HKP Development G

13.

FINISH GRADE

CL

E

Site Planning

SEAL:

F

LIMIT HIGH VOLUME IRRIGATION TO 60% OF THE LANDSCAPED AREA. ALL NEWLY PLANTED TREES SHALL HAVE INDIVIDUAL LOW FLOW OR MICRO-IRRIGATION SUPPLIES. ALL IRRIGATION SYSTEMS ARE RQUIRED TO HAVE A MOISTUR SENSOR/AUTOMATIC RAINFALL SHUTOFF DEVICE.

RESPONSIBILITY: ALL LANDSCAPING FROM THE APPROVED LANDSCAPE PLAN IS REQUIRED TO BE REPLACED IF AND/OR WHEN IT FAILS. OWNER IS RESPONSIBLE FOR THE SURVIVAL OF PLANTINGS. ALL TREE STAKING, IF INSTALLED, SHALL BE REMOVED WITHIN ONE YEAR FOLLOWING RECEIPT OF CERTIFICATE OF OCCUPANCY. IF A TREE THAT IS REQUIRED FOR MITIGATION OR TO FULFILL THE REQUIREMENTS OF THE LAND DEVELOPMENT CODE DIES OR IS SEVERELY DAMAGED, AS DETERMINED BY THE COUNTY'S REPRESENTATIVE, THEN THE TREE MUST BE REPLACED BY THE OWNER PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY.

E

LETTER OF COMPLIANCE: PROVIDE ONE WEEK NOTICE TO LANDSCAPE ARCHITECT REGARDING SCHEDULING THE FINAL REVIEW OF INSTALLED LANDSCAPE AND EXISTING VEGETATION PROTECTION FOR THE PURPOSES OF PREPARING THE LETTER OF COMPLIANCE.

MULCH, 3" THICKNESS TYPICAL. 1" MAXIMUM OVER ROOTBALL. SOIL BERM TO OUTSIDE OF ROOTBALL.

FINISH GRADE

PROJECT NO:

21-048

CLIENT'S NO.:

D

ISSUED FOR:

DEVELOPMENT PLAN REVIEW

ISSUED DATE:

04 OCT 2021

D

(5) LAYERS OF BURLAP

NOTE: SUBMIT SHOP DRAWINGS FOR STAKING LAYOUT AND DETAILS.

2 x 4 x 12, TYP. BATTEN (2) 1" NYLON STRAPS CUT BRACE TO BE FLUSH WITH BATTEN AND ATTACH WITH SCREWS

SCARIFY SIDE SLOPES

REVISIONS:

TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. 3 X ROOTBALL DIMENSION

06 DEC 2021 07 MAR 2022 02 MAY 2022

ROOTBALL ON EXISTING SOIL

AND GROUNDCOVER PLANTING DETAIL 3 SHRUB SCALE: N.T.S

C

NOTE: 1. FLAG TRAIL LOCATION IN FIELD FOR OWNER'S REPRESENTATIVE'S APPROVAL PRIOR TO INSTALLATION. 2. LAYOUT SUCH THAT NO DIRECTIONAL SLOPE IS GREATER THAN 5% AND NO CROSS SLOPE IS GREATER THAN 2%. 3. INSTALL SURFACING TO PROVIDE POSITIVE DRAINAGE OFF OF TRAIL SURFACE.

(3) 2 x 4 BRACES, VERTICAL, AND EVENLY SPACED AROUND TRUNK

ER NT CE G ON PACIN S

SAFETY FLAG AT MIDPOINT TOP OF ROOTBALL 1-2" ABOVE FINISH GRADE

8'

12" OFFSET FOR GROUNDCOVERS 18" OFFSET FOR SHRUBS

MULCH, 4" THICKNESS TYPICAL AND ONLY 1" OVER ROOTBALL 3" - 6" SOIL BERM TO OUTSIDE OF ROOTBALL FINISH GRADE

30" MIN. DEPTH

CL

EQUAL

BRACE NAILED TO 2 x 4 WOOD STAKE WITH TOP BELOW GRADE

2 X ROOTBALL WIDTH

ON CENTER SPACING

CRUSHED RECYCLED CONCRETE FINES, NO LARGER THAN 38" AND 50% PASSING NO. 4 SEIVE AND NO MORE THAN 15% PASSING NO. 200 SIEVE COMPACTED AND FLUSH WITH ADJACENT GRADE ADJACENT EXISTING GRADE

NOT APPLICABLE

B

SHEET TITLE:

OUTSIDE ROW FOLLOWS CURVE AS SHOWN. ROWS REMAIN PARALLEL AROUND CURVE.

LOOSEN SIDE SLOPES OF PLANTING PIT TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. ROOTBALL SITS ON BOTTOM OF PLANTING PIT

EQUAL

SCALE:

4"

1/3 TRUNK HEIGHT, MINIMUM

CLEAR TRUNK HEIGHT

C

B

CUT INTO GRADE AT EDGE OF BED SUCH THAT MULCH SURFACE MEETS FINISH GRADE.

WOVEN SYNTHETIC GEOTEXTILE FABRIC. TURN UP AT EDGES.

BEDLINE OR PAVING EDGE TRIANGULAR LAYOUT, TYPICAL, IN STRAIGHT RUNS AND AS MUCH AS POSSIBLE AROUND CURVES. ON CENTER SPACING DISTANCE SHALL BE AS INDICATED IN SCHEDULE.

A

PLANTING DETAIL 2 PALM SCALE: N.T.S.

4

NATIVE SUBGRADE A

SHRUB AND GROUNDCOVER LAYOUT DETAIL

5

SCALE: N.T.S

CRUSHED RECYCLED CONCRETE PATH DETAIL

LANDSCAPE SCHEDULE, NOTES, AND PLANTING DETAILS SHEET NUMBER:

SCALE: N.T.S

LS-6 1

2

3

4

5

6

7

8

9

10


1

2

4

3

5

7

6

8

9

10

MANLEY DESIGN Landscape Architecture

FINAL DEVELOPMENT PLAN CHECKLIST

PAVED GROUND SURFACE SHADING -PARKING LOT B

PROPOSED TREE CANOPY COVERAGE J

XIII. LANDSCAPE PLAN NOTES, DETAIL, AND CALCULATIONS

I N/A

Tree Planting Detail Tree Protection Detail Legend General Notes, Material, Grassed Areas, Irrigation, Details Tree Canopy Data, including: At least 5% of the existing tree canopy retained (ULDC 406.12(a)3.) At least 50% of parking areas under canopy at 20 yrs. (ULDC 407.43(d)3.h.) At least 30% of the site will be under canopy within 20 years parking areas under canopy at 20 yrs. (ULDC 406.12(a)3.) Tabular list of all regulated trees indicating the species of tree, the diameter at breast height, and if the tree will either remain or will be relocated, removed, or mitigated (ULDC 406.12(c)2.e.) Proposed mitigation table (tag number, species & caliper, required mitigation) Development Plan sheet reference map, if more than one development plan sheet

TREE NAME - SCIENTIFIC COMMON (SYM.)

XIV. DETAILED LANDSCAPE PLAN, MAXIMUM SCALE 1" = 50'

H N/A

Per Alachua County ULDC, Article IV., Sec. 407.43.1.c. Screening shall be provided where a paved ground surface area lies within 50 feet of and is visible from any street right-of-way. At least 50% of the paved ground surface area shall be under mature canopy within 20 years. Provided: Screening is not required since paved ground service is not visible from street right of way. See below for canopy.

Per Alachua County ULDC, Article II., Sec. 406.12 At least 30% of the site shall be under mature canopy within 20 years - % met as per below.

Existing tree size and type Location and field tag number for each regulated tree to remain undisturbed during construction (ULDC 406.12c.2.d.) Location of trees to be removed Proposed trees and shrubs location, type, and number Stormwater facilities comply with ULDC & MTPO design and landscape requirements Buffers & screening meet landscape requirements of pd, activity center, master plan and ULDC (ULDC 407.43) Silt fence and tree barrier location (ULDC 406.12.d.) Show proposed final grades & contours Show lighting and utilities to identify potential conflicts Landscape to be provided for driveway connections, offsite roadway improvements, and utility extensions

EST. 20-YR. CROWN

Acer rubrum 'Florida Flame' Florida Flame Red Maple (AR)

25

Lagerstroemia indica x faurei 'Muskogee' Muskogree Crape Myrtle (LIM)

15

Liriodendron tulipifera Tulip Tree (LT)

25

CROWN AREA PROPOSED (SF) QUANTITY 491

18

PROPOSED % OF CANOPY ON SITE

PROPOSED CANOPY AREA ON SITE (SF)

TREE NAME - SCIENTIFIC COMMON (SYM.)

8,838

100%

Liriodendron tulipifera Tulip Tree (LT)

Magnolia grandiflora 'Little Gem' Little Gem Dwarf Southern Magnolia (MG)

10

Pinus plaustris Longleaf Pine (PP)

25

177

12

491

79

491

Any substantial applicant-initiated revisions shall require payment of additional fees. The director shall determine if a proposed revision is to be deemed substantial, and the determination can include such factors as: 5.) reduction or relocation of proposed buffers landscaping or conservation areas

REQUIRED MITIGATION

25

491

10

100%

4,910

Platanus occidentalis Sycamore (PO)

40

1257

5

100%

6,285

Quercus michauxii Swamp Chestnut Oak (QM)

25

Quercus shumardii Shumard Oak (QS)

30

Quercus virginiana Live Oak (QV)

45

42

Mitigation required per Alachua County ULDC, Article II., Sec. 406.13.b. See Chart on Sheet LS-3.

100%

11

1591

Taxodium distichum Bald Cypress (TD)

20

Ulmus alata Winged Elm (UA)

40

Sabal palmetto Cabbage Palm (SP)

15

315

F

Mitigation surplus/defecit

Surplus: 201.5 inches (100 trees)

Mitigation required

Requirement satisfied

1257

177

15

15 Trees

Area (SF)

25% Area

10604

2651

Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412

Quercus virginiana Live Oak (QV)

45

1591

4

4,773.0

75%

25% Area in Landscape

2, 832 SF PROJECT NAME:

1591

4

I

3,182.0

50%

EAST BASIN

Total Shading SF Provided

9305.3

Total SF Paved Ground Surface

18,650 50

1 Canopy Tree / 35 LF Perimeter

25% Area in Landscape

Perimeter (LF)

Trees Required

PROVIDED

1550

44

45 trees

Area (SF)

25% Area

120060

30015

LAUREATE VILLAGE TND Phase 2, Unit 2

30,133 SF

H

EST. 20-YR. CROWN

CROWN AREA PROPOSED (SF) QUANTITY

PROPOSED % OF CANOPY ON SITE

Alacha County, FL

PROPOSED CANOPY AREA ON SITE (SF)

Ilex opaca American Holly (IO)

25

491

2

Liriodendron tulipifera Tulip Tree (LT)

25

Quercus virginiana Live Oak (QV)

45

1591

1

75%

1,193.3

Quercus virginiana Live Oak (QV)

45

1591

4

50%

3,182.0

for

245.5

25%

HKP Development 491

5

613.8

25%

G

9,135

100%

22

527

146,372

100%

37

PROVIDED

7,777

100%

29

Trees Required

Per Alachua County ULDC, Article IV., Sec. 407.43.1.c. Screening shall be provided where a paved ground surface area lies within 50 feet of and is visible from any street right-of-way. At least 50% of the paved ground surface area shall be under mature canopy within 20 years. Provided: Screening is not required since paved ground service is not visible from street right of way. See below for canopy.

20,622

100%

92

Perimeter (LF)

PAVED GROUND SURFACE SHADING -PARKING LOT C

REQUIRED MITIGATION

468 inches (234, 2" trees)

45

TREE NAME - SCIENTIFIC COMMON (SYM.) 707

1 Canopy Tree / 35 LF Perimeter

REQUIREMENT

G

Total inches of proposed trees as shown in plan

Quercus virginiana Live Oak (QV)

6,383

100%

Pinus taeda Loblolly Pine (PP)

491

REQUIREMENT

Certificate of Authorization No. LC26000575

Per Alachua County ULDC, Article II., Sec. 402.07.a.

266.5 inches

1,350.3

25%

% Shaded Paved Ground Surface

DEVELOPMENT REVIEW FEES

Mitigation required as per 'Tree Preservation & Removal Plan' calculations

11

PROPOSED CANOPY AREA ON SITE (SF)

869

100%

13

491

PROPOSED % OF CANOPY ON SITE

27,005

100%

11

25

CROWN AREA PROPOSED (SF) QUANTITY

J

WEST BASIN

2,124

100%

55

EST. 20-YR. CROWN

LANDSCAPING OF STORMWATER MANAGEMENT FACILITIES Per Alachua County ULDC, Article IV., Sec. 407.43.2.

Site Planning

46,509

100%

SEAL:

3,894 Total Shading SF Provided

5234.5 10,044

Total Proposed 20-Year Canopy (SF)

290723

Total SF Paved Ground Surface

Total Existing Canopy Retained (SF)

83635

% Shaded Paved Ground Surface

Total Canopy (SF)

374358

F

52

PAVED GROUND SURFACE SHADING -PARKING LOT D Site Area (SF) - excluding CHW commercial parcel

PRESERVATION OF EXISTING TREE CANOPY

% Site Under Canopy at 20-Years

Per Alachua County ULDC, Article II., Sec. 406.12A minimum of 5% of the tree canopy shown on the property's most recent aerial shall be retained. E

EXISTING (AC)

REQUIRED (AC)

RETAINED (AC)

Per Alachua County ULDC, Article IV., Sec. 407.43.1.c. Screening shall be provided where a paved ground surface area lies within 50 feet of and is visible from any street right-of-way. At least 50% of the paved ground surface area shall be under mature canopy within 20 years. Provided: Screening is not required since paved ground service is not visible from street right of way. See below for canopy.

32

TREE NAME - SCIENTIFIC COMMON (SYM.)

STREET TREES Per Alachua County ULDC, Article IV., Sec. 407.43.1.b. Provide along both sides of streets and roads or in medians and within a minimum 8 ft. wide planting strip. Plant in the center 30% of the planting strip. Street trees in commercial or mixed use districts may be planted in islands or bulb-outs where on-street parking is present. Parking islands or bulb-outs shall have a minimum pervious area of 90 SF and be free of compacted soil to a depth of 18". Street trees shall be spaced so that the distance between two adjacent trunks is no less than one half the sum of their 20-year canopy crowns and no more than the sum of their 20-year canopy crowns. Street trees shall be planted between the street and the sidewalk whenever space permits to protect pedestrians and calm traffic. Eligible trees as per Table 407.50.1.

See Civil Sheet 'Tree Canopy Preservation Plan, TREE CANOPY TABLE' for calculations to support below:

PHASE

1,162,418

RETAINED % OF TOTAL

Phase 1, Unit 1 & 2

19.87-AC *

0.00-AC *

4.51-AC *

22.70%

Phase 1, Unit 3

23.14-AC *

0.00-AC *

3.27-AC *

14.13% Provided: See plan for street trees planted along project drives. Above requirement is met.

Phase 2, Unit 1 & 2

2.60-AC *

0.00-AC *

1.92-AC *

73.85%

Future

20.81-AC *

3.33-AC *

TBD

TBD

TOTALS

66.52-AC *

3.33-AC *

9.70-AC

14.58%

ROADWAY LANDSCAPE BUFFERS Per Alachua County ULDC, Article IV., Sec. 407.43.d.

D

Location / Type Requirement North / 'ARTERIAL/COLLECTOR' 10 ft. average & 5 ft. minimum width Per 100/LF: 2 - Canopy trees 2 - Understory trees

TREE SPECIES DIVERSITY Per Alachua County ULDC, Article IV., Sec. 407.11.a. New tree plantings shall not include more than 50 percent of any one genus or 25 percent of any one species. Total Proposed Trees C

Length (LF)

Per 100 LF

Required

Provided

Total Proposed Species (Quercus virginiana) %

1001

10.01

20

25

491

1

50%

245.5

Liriodendron tulipifera Tulip Tree (LT)

25

491

16

25%

1,964.0

Quercus virginiana Live Oak (QV)

45

1591

4

75%

4,773.0

Quercus virginiana Live Oak (QV)

45

Ulmus alata Winged Elm (UA)

40

E

PROJECT NO:

1591

1257

4

2

ISSUED FOR:

DEVELOPMENT PLAN REVIEW

ISSUED DATE:

04 OCT 2021

D

1885.5

75%

21-048

CLIENT'S NO.:

3,182.0

50%

Total Shading SF Provided

12050.0

Total SF Paved Ground Surface

22,314

% Shaded Paved Ground Surface

06 DEC 2021 07 MAR 2022 02 MAY 2022

54

C

92 = 25%

Per Alachua County ULDC, Article IV., Sec. 407.43.1.c. Screening shall be provided where a paved ground surface area lies within 50 feet of and is visible from any street right-of-way. At least 50% of the paved ground surface area shall be under mature canopy within 20 years. Provided: Screening is not required since paved ground service is not visible from street right of way. See below for canopy.

Per Alachua County ULDC, Article IV., Sec. 407.43.1.a. Areas dedicated to pedestrian circulation that are not coincident with a street shall have canopy trees spaced not more than an average of 40 feet on center. B

EST. 20-YR. CROWN

CROWN AREA PROPOSED (SF) QUANTITY

PROPOSED % OF CANOPY ON SITE

PAVED GROUND SURFACE SHADING -PARKING LOT E Per Alachua County ULDC, Article IV., Sec. 407.43.1.c. Screening shall be provided where a paved ground surface area lies within 50 feet of and is visible from any street right-of-way. At least 50% of the paved ground surface area shall be under mature canopy within 20 years. Provided: Screening is not required since paved ground service is not visible from street right of way. See below for canopy.

PROPOSED CANOPY AREA ON SITE (SF)

Liriodendron tulipifera Tulip Tree (LT)

25

491

2

25%

245.5

Quercus virginiana Live Oak (QV)

45

1591

2

75%

2,386.5

Quercus virginiana Live Oak (QV)

45

TREE NAME - SCIENTIFIC COMMON (SYM.)

#1 pedestrian walkway along north/west boundaries 687

17

5 existing to remain; 12 proposed

#2 pedestrian walkway along west/south boundaries 1623

41

17 existing to remain; 54 existing to remain just west of property line; 29 proposed

1591

4

50%

3,182.0

Total Shading SF Provided

5814.0

Total SF Paved Ground Surface

11,526

% Shaded Paved Ground Surface

EST. 20-YR. CROWN

CROWN AREA PROPOSED (SF) QUANTITY

438

11

PROPOSED % OF CANOPY ON SITE

45

1591

1

75%

1,193.3

Quercus virginiana Live Oak (QV)

45

1591

1

50%

795.5

Quercus virginiana Live Oak (QV)

45

1591

2

25%

795.5

Ulmus alata Winged Elm (UA)

40

1257

3

50%

1,885.5

50

Total Shading SF Provided

4669.8

Total SF Paved Ground Surface

8,357

% Shaded Paved Ground Surface

12 proposed

SCALE:

PROPOSED CANOPY AREA ON SITE (SF)

Quercus virginiana Live Oak (QV)

#3 pedestrian walkway in central park Total LF = 438 LF/40

PROPOSED CANOPY AREA ON SITE (SF)

Liriodendron tulipifera Tulip Tree (LT)

19 Canopy trees proposed, 1 to remain 20 Understory Trees

PAVED GROUND SURFACE SHADING -PARKING LOT A

PEDESTRIAN WALKWAYS LANDSCAPING

A

PROPOSED % OF CANOPY ON SITE

REVISIONS:

145 = 40%

TREE NAME - SCIENTIFIC COMMON (SYM.)

Total LF = 1623 LF/40

CROWN AREA PROPOSED (SF) QUANTITY

357

Total Proposed Genus (Quercus) %

Total LF = 677 LF/40

EST. 20-YR. CROWN

NOT APPLICABLE

B

SHEET TITLE:

LANDSCAPE CALCULATIONS A

56

SHEET NUMBER:

LS-7 1

2

3

4

5

6

7

8

9

10


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.