LEX BOENKER, MLA CONSTRUCTION DOCUMENT SAMPLES 2022
1
2
4
3
5
7
6
8
9
10
LANDSCAPE NOTES 1.
EXISTING UTILITIES: LOCATE ALL UTILITIES PRIOR TO COMMENCEMENT OF WORK. CALL SUNSHINE STATE ONE CALL - SEE LOGO BELOW.
2.
PLANTING PREPARATION: REMOVE ALL CONSTRUCTION DEBRIS, LIMEROCK, GRAVEL, ROAD BEDDING, LITTER, AND OTHER ITEMS POTENTIALLY DAMAGING TO PLANT GROWTH WITHIN PROPOSED LANDSCAPE AND TURF AREAS PRIOR TO PLANTING. MAINTAIN EXISTING GRADES UNLESS OTHERWISE APPROVED BY THE OWNER'S REPRESENTATIVE. IF FILL IS REQUIRED, USE A CLEAN, SANDY LOAM WITH pH 5.5-6.5 AND EXCAVATED FROM LOCAL SOURCES AND DEEP PITS SUCH THAT IT IS FREE OF WEEDS, SEEDS, LITTER, TOXINS, AND OTHER ITEMS HARMFUL TO PLANTINGS.
J
QTY 2
BOTANICAL NAME Betula nigra `Duraheat`
COMMON NAME Duraheat River Birch
SIZE 15 gal., 8` ht. x 36" spr., 1.5" cal.
SPACING As shown
14
Cercis canadensis
Eastern Redbud
30 gal., 8` ht. x 30" sprd., 1.5" cal.
As shown
LT
4
Liriodendron tulipifera
Tulip Poplar
15 gal., 8` ht. x 36" spr., 1.5" cal.
As shown
QM
4
Quercus michauxii
Swamp Chestnut Oak
15 gal., 8` ht. x 36" spr., 1.5" cal.
As shown
4.
PLANT MATERIAL, GENERAL: ALL PLANT MATERIALS SHALL MEET 'FLORIDA NUMBER 1' REQUIREMENTS AS PER THE MOST CURRENT EDITION OF 'FLORIDA GRADES AND STANDARDS FOR NURSERY PLANTS', FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES.
PALMS SP
QTY 11
BOTANICAL NAME Sabal palmetto
COMMON NAME Cabbage Palmetto
SIZE Height as shown, 12" min. cal. at 4.5` above grade
SPACING As shown
NOTES Regenerated
5.
PROPOSED TREES: TREES PROPOSED SHALL BE A MINIMUM OF EIGHT FEET TALL.
6.
NEW TREE STAKING: IF NECESSARY TO MAINTAIN TREES PLUMB, TREES SHALL BE STAKED WITH BIODEGRADABLE STAKING MATERIALS.
SHRUBS IV
QTY 39
BOTANICAL NAME Ilex vomitoria 'Schillings Dwarf'
COMMON NAME Schillings Dwarf Yaupon Holly
SIZE 3 gal., 24" ht. x 18" sprd.
SPACING 30" o.c.
NOTES
7.
DISTURBED AREAS: PROVIDE THREE ROWS OF SOD ALONG ALL PAVEMENT. PROVIDE SOD IN DISTURBED AREAS OF SITE AND ON ANY SLOPES 4:1 OR GREATER. SEE CIVIL PLANS FOR GRASSING REQUIREMENTS FOR STORMWATER PONDS. SOD TYPE SHALL BE PER THE PLANT SCHEDULE. SOD SHALL BE SAND-GROWN, STRONGLY ROOTED, WITHOUT SYNTHETIC STABILIZING MATERIALS, FREE OF PESTS, AND CERTIFIED FREE OF NOXIOUS WEEDS BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES, DIVISION OF PLANT INDUSTRY. SEED SHALL BE CLEAN AND DRY WITH A MIN. 80% GERMINATION RATE. SEE CIVIL PLANS FOR SODDING INFORMATION FOR STORMWATER FACILITIES.
MC
92
Muhlenbergia capillaris
Pink Muhly
3 gal., 24" ht. x 18" sprd.
36" o.c.
MULCH PSW
QTY 944 sf
BOTANICAL NAME Pine Straw
COMMON NAME Pine Straw
SIZE 3" depth, when settled, free of sticks and cones
SPACING
NOTES on slopes
SOD/SEED SOD
QTY 74 sf
BOTANICAL NAME Paspalum notatum `Argentine`
COMMON NAME Argentine Bahia Grass
SIZE sod
SPACING
NOTES Sand grown and weed free
8.
MULCH: MULCH TO BE PINESTRAW, FREE OF CONES, BRANCHES, AND DEBRIS TO A DEPTH OF 3",SETTLED, AT ALL NEW PLANTINGS. AT INSTALLATION, MULCHES SHALL BE APPLIED AT A DEPTH OF AT LEAST TWO INCHES. NO VISIBLE PLASTIC SURFACE COVERS SHALL BE USED.
9.
IRRIGATION: ALL LANDSCAPED AREAS SHALL BE PROVIDED WITH AN IRRIGATION SYSTEM OR A READILY AVAILABLE WATER SUPPLY LOCATED WITHIN 100 FEET. SEE IRRIGATION PLAN.
10.
RESPONSIBILITY: DEAD OR SEVERELY DAMAGED OR DISEASED PLANT MATERIAL SHALL BE REPLACED IN ACCORDANCE WITH THE STANDARDS SPECIFIED IN CITY OF NEWBERRY CODE OF ORDINANCES CHAPTER 74 PLANNING - ARTICLE III. - TREE CITY ORDINANCE SEC. 74-69., WITHIN A TIME PERIOD APPROPRIATE TO THE GROWING SEASON OF THE SPECIES IN QUESTION, BUT NOT EXCEEDING ONE YEAR. ALL PLANTINGS SHALL BE MAINTAINED IN A HEALTHY GROWING CONDITION AT ALL TIMES.
SITE CANOPY AND UNDERSTORY TREES Required
Acres
Front / 3 canopy trees per acre Sides and Rear / 2 canopy trees per acre
6 - Understory trees
2.34
2.34
2.34
7.02
4.68
14.04
Provided
7.02
7 Canopy trees
4.68
East: 5 Canopy trees West: 5 Canopy trees Rear: 5 Canopy trees
R
North and South / Per 100/LF: 4 Canopy trees
20
0.20
46
0.46
Provided
TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. ROOTBALL SITS ON BOTTOM OF PLANTING PIT
EQUAL
2 X ROOTBALL WIDTH
East: 2 Canopy trees West: 2 Canopy trees
PHASE 2
East and West / Per 100/LF: 4 Canopy trees
44
0.71
0.44
Provided
2.84
North: 3 Canopy trees South: 3 Canopy trees
MULCH, 3" THICKNESS TYPICAL. 1" MAXIMUM OVER ROOTBALL. SOIL BERM TO OUTSIDE OF ROOTBALL.
FINISH GRADE
2 - LT 2 - SP
ELLIANOS COFFEE SHOP
FUTURE RETAIL BUILDING
10' C.T.
23 - IV
2
1 - QM
18 - MC 8 - IV EXISTING FENCE TO REMAIN
E
21-015
PROJECT NO:
1 - LT
CLIENT'S NO.:
SOD
1 - SP
1 - QM
10' C.T.
TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. 3 X ROOTBALL DIMENSION
Provided along each facade as close to building as proposed paving and site layout allows
F
1 - SP
14' C.T.
SCARIFY SIDE SLOPES
Provided
C
1 - QM
17 - MC
10' C.T.
CUT INTO GRADE AT EDGE OF BED SUCH THAT MULCH SURFACE MEETS FINISH GRADE.
SHRUBS
Row of shrubs along each facade
PHASE 1 PHASE 2
1 - SP
8 - IV
1 - SP
10' C.T.
East: 2 Canopy trees West: 2 Canopy Trees
1.76
Per Developer Agreement NO. DA-LDR 21-35. Requirement
14' C.T.
14' C.T.
MULCH, TYP.
Required
G
1 - QM
PHASE 1 PHASE 2
D
71
Mr. Eric Preston
SOD DISTURBED AREAS, TYP.
Per Developer Agreement NO. DA-LDR 21-35.
North and South / Per 100/LF: 4 Canopy trees
for
2 - SP
PLANTING DETAIL 1 TREE SCALE: N.T.S
FACADE TREES - FUTURE RETAIL BUILDING LF
14' C.T.
6 - MC
LOOSEN SIDE SLOPES OF PLANTING PIT
E
Location / Requirement
Newberry, FL
1 - LT
SOD
North: 1 Canopy tree South: 1 Canopy tree
1.84
H
25 - MC
CL
EQUAL East and West / Per 100/LF: 4 Canopy trees
ELLIANOS COFFEE SHOP
”
18' C.T.
SOD DISTURBED AREAS, TYP.
FINISH GRADE
0.80
I
“
MULCH, 3" THICKNESS TYPICAL AND ONLY 1" OVER ROOTBALL
Per Developer Agreement NO. DA-LDR 21-35.
Required
PROJECT NAME:
TOP OF ROOTBALL 1-2" ABOVE FINISH GRADE
FACADE TREES - ELLIANOS COFFEE SHOP LF
Certificate of Authorization No. LC26000575
2 - SP
3" - 6" SOIL BERM TO OUTSIDE OF ROOTBALL
Location / Requirement
J
SEAL:
14 Understory trees
14.04
W
/ D A O
6 SR 2
Site Planning
Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412
SW 246TH TER
Location / Requirement
Y BERR
W
NE T S E
NOTE: 1. ENSURE PLANTING PIT DRAINS WELL PRIOR TO INSTALLATION. 2. REMOVE TREE FROM CONTAINER OR REMOVE UPPER 1/3 OF BURLAP AND WIRE MESH FOR B&B TREES. 3. SLICE ROOTBALL VERTICALLY ON OUTSIDE EDGES OF AND AROUND ROOTBALL. 4. TREE TO BE PLUMB. STAKE TREE IF NEEDED. SUBMIT TREE STAKING DETAILS AND LAYOUT FOR APPROVAL.
Per Developer Agreement NO. DA-LDR 21-35.
F
NOTES Multi-trunk, 3 canes minimum
CC
H
G
TREES BN
PRUNING: IF TREE OR ROOT PRUNING IS REQUIRED, THESE ACTIVITIES SHALL BE PERFORMED BY AN ARBORIST CERTIFIED BY THE INTERNATIONAL SOCIETY OF ARBORICULTURE (ISA). TREE PRUNING SHALL BE DONE IN ACCORDANCE WITH THE MOST CURRENT VERSION OF THE AMERICAN NATIONAL STANDARD FOR TREE CARE OPERATIONS "TREE. SHRUB AND OTHER WOODY PLANT MAINTENANCE" (ANSI 300) AND "PRUNING. TRIMMING. REPAIRING. MAINTAINING, AND REMOVING TREES. AND CUTTING BRUSH—SAFETY REQUIREMENTS" (ANSI Z133). NO MORE THAN 25 PERCENT OF THE CROWN SHOULD BE REMOVED AT ONE TIME. ON YOUNG TREES, LIMB REMOVAL SHALL LEAVE NO MORE THAN 33 PERCENT OF THE TRUNK BARE OF BRANCHES.
3.
I
Landscape Architecture
PLANT SCHEDULE
1 - SP
2 - CC
3 - CC
20 - MC
1 - BN
ROOTBALL ON EXISTING SOIL
SITE PLAN REVIEW
ISSUED DATE:
29 APR 2022
D
MULCH, TYP.
1 - BN
ISSUED FOR:
REVISIONS:
6 - MC
SOD 3 - CC
SHRUB AND GROUNDCOVER PLANTING DETAIL
3 - CC
C
BASIN 1
SCALE: N.T.S
SILT FENCE
SEE CIVIL PLANS FOR GRASSING OF STORMWATER SWALES AND FACILITIES, TYP. SCALE:
12" OFFSET FOR GROUNDCOVERS 18" OFFSET FOR SHRUBS
ER NT CE G ON ACIN SP
B
SOD DISTURBED AREAS, TYP.
ON CENTER SPACING
3 - CC
0
BEDLINE OR PAVING EDGE
PROPOSED TREE
TRIANGULAR LAYOUT, TYPICAL, IN STRAIGHT RUNS AND AS MUCH AS POSSIBLE AROUND CURVES. ON CENTER SPACING DISTANCE SHALL BE AS INDICATED IN SCHEDULE.
A
3 1
2
3
A
LS-2
SCALE: N.T.S
4
LANDSCAPE PLAN, SCHEDULE, NOTES, DETAILS AND CALCULATIONS SHEET NUMBER:
SHRUB AND GROUNDCOVER LAYOUT DETAIL 5
6
7
8
9
10
40'
SHEET TITLE:
LEGEND
OUTSIDE ROW FOLLOWS CURVE AS SHOWN. ROWS REMAIN PARALLEL AROUND CURVE.
20'
SCALE: 1" = 20'
B
NORTH
10'
1
2
4
3
5
7
6
8
9
10
Landscape Architecture J
I
J
ON CENTER SPACING
PLANT SCHEDULE SHRUBS AG
QTY 73
BOTANICAL NAME Agapanthus africanus ` Ella Mae`
COMMON NAME Ella Mae Agapanthus
SIZE 3 gal., 16" ht. x 14" spr.
SPACING 30" o.c.
NOTES Full
DE
22
Dioon edule
Mexican Cycad
7 gal., 36" ht. x 36" sprd.
As shown
Full
NC
9
Nerium oleander 'Calypso'
Calypso Oleander
3 gal., 36" ht. x 30" sprd.
60" o.c.
OH
35
Opuntia humifusa
Prickly Pear
7 gal., 36" ht. x 24" sprd.
48" o.c.
RC
228
Rosa x `Coral Drift`
Coral Drift Rose
3 gal., 12" ht. x 18" sprd.
24" o.c.
YU
54
Yucca filamentosa 'Blue Sentry'
Adam's Needle
3 gal., 24" ht. x 24" sprd.
36" o.c.
Full
GROUND COVERS HD
QTY 168
BOTANICAL NAME Helianthus debilis
COMMON NAME Dune Sunflower
SIZE 1 gal., 12" ht. x 18" sprd.
SPACING 30" o.c.
NOTES
JB
303
Juniperus conferta `Blue Pacific`
Blue Pacific Juniper
1 gal., 6" ht. x 12" sprd.
24" o.c.
TA
311
Trachelospermum asiaticum `Tri Color`
Tri Color Asiatic Jasmine
1 gal., 6" ht. x 12" sprd.
18" o.c.
Full
SOD/SEED SOD
QTY 4,545
BOTANICAL NAME Paspalum notatum `Argentine`
COMMON NAME Bahia Grass
SIZE sod
SPACING
NOTES Sand grown and weed free
FINISH GRADE
ON CENTER SPACING
Certificate of Authorization No. LC26000575 PROJECT NAME:
I
TECH CITY ENTRY
BEDLINE OR PAVING EDGE
SCARIFY SIDE SLOPES TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. 3 X ROOTBALL DIMENSION
1
ON CENTER SPACING
Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412
OUTSIDE ROW FOLLOWS CURVE AS SHOWN. ROWS REMAIN PARALLEL AROUND CURVE.
CUT INTO GRADE AT EDGE OF BED SUCH THAT MULCH SURFACE MEETS FINISH GRADE.
H
12" OFFSET FOR GROUNDCOVERS 18" OFFSET FOR SHRUBS
MULCH, 3" THICKNESS TYPICAL. 1" MAXIMUM OVER ROOTBALL. SOIL BERM TO OUTSIDE OF ROOTBALL.
TRIANGULAR LAYOUT, TYPICAL IN STRAIGHT RUNS AND AS MUCH AS POSSIBLE AROUND CURVES. ON CENTER SPACING DISTANCE SHALL BE AS INDICATED IN SCHEDULE.
ROOTBALL ON EXISTING SOIL
SHRUB AND GROUNDCOVER PLANTING DETAIL
2
SCALE: N.T.S.
Site Planning
H
SHRUB AND GROUNDCOVER LAYOUT DETAIL
Alachua, FL
SCALE: N.T.S.
for
LANDSCAPE NOTES
86 - HD G
3 - NC
F
7 - DE 11 - OH
E
LOCATE ALL UTILITIES PRIOR TO COMMENCEMENT OF WORK. CALL SUNSHINE STATE ONE CALL - SEE LOGO.
2.
COMPLY WITH ALL STATE AND LOCAL CODES.
3.
ALL PLANT MATERIALS SHALL MEET 'FLORIDA NUMBER 1' REQUIREMENTS AS PER THE MOST CURRENT EDITION OF 'FLORIDA GRADES AND STANDARDS FOR NURSERY PLANTS', FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES.
4.
SOD SHALL BE SAND-GROWN, STRONGLY ROOTED, FREE OF WEEDS, PESTS, AND NOXIOUS SPECIES, AND NOT DORMANT. PROVIDE SOD OF A UNIFORM PAD SIZE AND OF A GROWTH SUCH AS TO BE ABLE TO GRASPED AND LIFTED WITHOUT BREAKING APART. DO NOT USE SYNTHETIC STABILIZING MATERIALS WITHIN OR BELOW SOD.
5.
SUBSTITUTIONS SHALL NOT BE ACCEPTED UNLESS OWNER'S REPRESENTATIVE APPROVES A SUBMITTAL FROM THE CONTRACTOR INCLUDING THE REASON FOR REQUESTED SUBSTITUTIONS AND A LIST OF ALL REQUESTED ALTERNATIVE MATERIALS WITH SCIENTIFIC AND COMMON NAMES, VARIETIES, SIZES, AND COST DIFFERENCE PER PLANT TYPE. SUBMITTAL SHALL BE APPROVED PRIOR TO ORDERING OF REQUESTED SUBSTITUTIONS.
14 - AG
EXISTING PLANTING TO REMAIN, TYP. LOCATION IS APPROXIMATE
FILL GAPS IN EXISTING PLANTING WITH AGAPANTHUS
15 - AG
6 - NC 66 - RC
EXISTING TREES TO REMAIN, TYP.
125 - TA
7 - YU
15 - YU
6.
PROTECT EXISTING IMPROVEMENTS, TREES, LANDSCAPE, AND TURF TO REMAIN DURING CONSTRUCTION. PROVIDE IRRIGATION AND MAINTENANCE OF EXISTING MATERIALS TO REMAIN WITHIN PROJECT AREA DURING CONSTRUCTION AND UNTIL FINAL ACCEPTANCE. REPLACEMENT OF EXISTING VEGETATION OR PLANTINGS OR RESTORATION OF AREAS IMPACTED BY CONSTRUCTION ACTIVITIES WILL BE AT THE COST OF THE CONTRACTOR.
7.
MAINTAIN EXISTING GRADES UNLESS OTHERWISE APPROVED BY THE OWNER'S REPRESENTATIVE. IF FILL IS REQUIRED, USE A CLEAN, SANDY LOAM EXCAVATED FROM LOCAL SOURCES AND DEEP PITS SUCH THAT IT IS FREE OF WEEDS, SEEDS, LITTER, TOXINS, AND OTHER ITEMS HARMFUL TO PLANTINGS.
8.
REMOVE ALL CONSTRUCTION DEBRIS AND LIMEROCK, GRAVEL, ROAD BEDDING, LITTER, AND OTHER ITEMS POTENTIALLY DAMAGING TO PLANT GROWTH WITHIN THE PROPOSED PLANTING AND TURF AREAS PRIOR TO PLANTING. PROVIDE A MINIMUM THREE FOOT DEEP PLANTING DEPTH FOR ALL PROPOSED PLANTING AND TURF AREAS.
11 - OH
EXISTING SIGN
9.
PROTECT TREES, SHRUBS, AND GROUNDCOVERS DURING AND UPON DELIVERY. KEEP PLANTS WATERED AND WITHIN CONTAINERS UNTIL PLANTING. DO NOT PRUNE PRIOR TO OR FOLLOWING DELIVERY UNLESS APPROVED BY THE OWNER'S REPRESENTATIVE.
10.
IRRIGATION: SEE IRRIGATION PLANS.
11.
MULCH: INSTALL 3" OF PINE STRAW MULCH, SETTLED, IN ALL PROPOSED PLANTING AREAS.
SOD 66 - JB
20 - AG
38 - RC
10 - DE 8 - OH
G
1.
SEAL:
F
E
21-053
PROJECT NO: CLIENT'S NO.:
21 - YU 92 - RC
D
LASER INVESTMENT GROUP
11 - YU
ISSUED FOR:
CONSTRUCTION
ISSUED DATE:
26 AUG 2021
D
REVISIONS:
79 - TA
5 - DE 5 - OH 39 - HD 24 - AG
C
C
32 - RC 113 - JB
124 - JB 107 - TA
SCALE:
43 - HD SOD
APPROXIMATE SIZE AND LOCATION OF PROPOSED GROUND SIGN
PROPOSED PLANTING NOT TO EXTEND BEYOND RIGHT OF WAY LIMIT
B
0
5'
10'
20'
SCALE: 1" = 10'
B
SHEET TITLE:
SR A
20 /
HW
LANDSCAPE PLAN, PLANT SCHEDULE, NOTES AND DETAILS
Y 44
1
A
NORTH
SHEET NUMBER:
L-101 1
2
3
4
5
6
7
8
9
10
1
2
4
3
5
7
6
8
9
Landscape Architecture
MATCHLINE L-201.B
J
10
LEGEND
MATCHLINE L-201.A
Site Planning
J
POC
.1
T
Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412
POINT OF CONNECTION TO EXISTING MAIN LINE AND 2-WIRE CONTROL WIRES
.1
T
TORO DL 2000 1 GPH, 12'' O.C. PR. REG. DRIP TUBING
Certificate of Authorization No. LC26000575
.1
T
CLASS 200 2'' PVC SOLVENT WELD MAIN LINE ROUTING CL 200 SOLVENT WELD PVC ZONE PIPE ROUTING
I
PROJECT NAME:
I
4'' DIRECTIONAL BORE - CONSULT WITH OWNER AS TO POSSIBLE EXISTING AVAILABLE SLEEVING
TECH CITY ENTRY
.1
T
.1
T
HUNTER ICV-151G-FS-AS-ADJ 1.5'' VALVE WITH DUAL-1 DECODER AND DUAL-S SURGE ARRESTOR
.1
T
LOCATION OF DRIP AIR/VACUUM RELIEF VALVE, LINE FLUSHING VALVE AND RAIN BIRD OPERIND
.1
T
2'' GATE VALVE
H
H
VALVE STATION, SIZE, APPLICATION AND GALLONAGE
2
for
11
.1
T
11
4
.1
T
.1
T
.1
T
.1
T
Alachua, FL
G
POC
.1
.1
T
T
.1
T
.1
11 '
T
G
2'
.1
T
MH-10
LASER INVESTMENT GROUP
SEAL:
EXISTING MAINLINE
.1
T
F
1''
T
.1
T
.1
T
F
.1
.1
T
T
.1
.1
T
T
CONNECT EXISTING DRIP TUBING TO THE NEW DRIP TUBING AT THESE POINTS.
.1
T
.1
.1
T
.1
4'' DIR. BORE
.1
T
.1
.1
T
112''
E
S-15
.1
E
FILL GAPS IN EXISTING PLANTING WITH AGAPANTHUS
EXISTING TREES TO REMAIN, TYP.
T
112''
T
.1
T
112''
112''
T
.1
T
EXISTING PLANTING TO REMAIN, TYP. LOCATION IS APPROXIMATE
EXISTING SIGN
.1
.1
T
1''
112''
112''
11 4''
.1
D
T
1''
S-13
S-17
CLIENT'S NO.:
GROUND 2-WIRE SYSTEM AT VALVES' LOCATION.
CONSTRUCTION
ISSUED DATE:
26 AUG 2021
REVISIONS:
.1
T
T
.1
.1
T
112''
1730 L.F. 26 GPM
.1
T
.1
T
1''
ISSUED FOR:
D
11 4''
2110 L.F. 31.7 GPM
21-053
PROJECT NO:
.1
112''
T
SOD
T
11 4''
C
2280 L.F. 34.2 GPM
C
1''
SCALE:
T
1470 L.F. 22.1 GPM
.1
SOD
SR
A
20 /
HW
.1
1
A
MATCHLINE L-201.A
NORTH
SHEET NUMBER:
MATCHLINE L-201.B 1
2
3
4
5
6
7
8
20'
IRRIGATION PLAN AND SCHEDULE
B
Y 44
10'
SHEET TITLE:
.1
A
5'
SCALE: 1" = 10'
B
T
B
0
T
APPROXIMATE SIZE AND LOCATION OF PROPOSED GROUND SIGN
PROPOSED PLANTING NOT TO EXTEND BEYOND RIGHT OF WAY LIMIT
L-201 9
10
TB
SEED, TYP.
5 - GP
TB
1 - LIM
TB
WL
TB
TB
TF - 38
1 - LIM
WM
TB
TB
3 - LIM
SAN
TB
TB
TB
TB
3 - RE 1 - TD
1 - TD
HD - 21
1 - TD
15 - MC 19 - CR
7 - MC
TB
TB
TB
TB
TB
33 .0 TB
SOD, TYP.
TB
TB TB TB
TB
TB
TB
TB
TB
CN - 3
TB
MC - 19 1 - PD 1 - ED
1 - PD 3 - CN
IN - 16 47 - ND CN - 3
1 - PD
27 - ND 1 - TD ND - 5
1 - TD
MATCHLINE SHEET L-102
TB
5 - MC 3 - RE
TB
TB
Site Planning
J
Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412
16 - CR
Certificate of Authorization No. LC26000575
13 - PMP 3 - RE
PROJECT NAME:
I
3 - IV
ORCHID LAKE
TB
TB
TB
TB
TB
TB
1 - TD
6 - IN 9 - PMP TB
TB
1 - LIM
Landscape Architecture
1 - TD
1 - TD
SAN
3 - ED 12 - PMP 9 - MC
1 - TD
1 - IE 3 - SP
SAN 1 - TD
10 - MC
10
1 - LIM
HD - 10 11 - IN WM A/C UNITS, TYP.
2 - SP
WM
SAN 25 - CR
11 - AG 1 - ED
ND - 3
TB
TB
TB
WL
TB
TB
TF - 11 IN - 9 11 - HD 2 - TC
TB
TB
MAINT.
12 - PMP
1 - TD 27 - CR MC - 8
IN - 23
TB
19 - IN
1 - ED 15 - TF
TB
WL
SAN
2 - PD
TB
TB
TB
I
20 - GP
25 - TF
WM
1 - IE
TB
SOD, TYP.
1 - LIM HD - 9
1 - LIM
SOD, TYP.
WM
1 - QV
4 - IN
17 - EB FL
TB
HD - 37
6 - CM
IN - 17
HD - 9
TB
TB
7 - TD
TB
SOD
6 - CM
TF - 23
TB
TB
DRY STORMWATER POND
3 - LIM
SAN
TF - 15
IN - 4
2 - QV
9
MATCHLINE SHEET L-101
ND - 2
6 - TF
3 - IN
WM
TB
SAN
J
HD 7
4 - IN
HD - 5
8
TB
TF - 10
7
6
TB
1 - TD
5
TB
4
3
13 - MC
TB
2
TB
1
1 - TD 1 - PD
TB
H
TB
H
TB
Cocoa, FL
TB
PROPERTY BOUNDARY
TB
NORTH
TB TB
HTG Orchid Lake, Ltd.
TB
PROPERTY BOUNDARY
for
LEGEND
24 LA
TB
G
EXISTING TREES AND
G
TB
VEGETATION TO REMAIN
TB TB
TB
TB
TB
TB
TB
TB TB
TB
MULCH UNDER EXISTING TREES TO REMAIN IN AREA OUTLINED
TB TB
F
TREE BARRICADE, TYP.
TB
TB
TB
TB
TB
TB
TB
TB
TB
AREA ASSUMED AS UNDISTRUBED
F
AREA UNDER EXISTING TREES TO REMAIN AS IS
TB TB
PLANT SCHEDULE
TB
SEED, TYP.
TB
PROVIDE 2 STRIPS OF SOD ALONG DRIVE EDGE, TYP.
TB
TB
TB
TB TB
TB
TB
TB
TB
TB
TREES ED
QTY 11
BOTANICAL NAME Elaeocarpus decipiens
COMMON NAME Japanese Blueberry Tree
SIZE 45 gal., 8` ht., 28" sprd., 3" cal.
SPACING As shown
NOTES
IV
30
Ilex vomitoria
Yaupon Holly
45 gal., 7` ht. x 42" sprd., 3" cal.
As shown
IE
26
Ilex x attenuata 'Eagleston'
Eagleston Holly
45 gal., 8` ht., 28" sprd., 3" cal.
As shown
LIM
50
Lagerstroemia indica x faurei `Muskogee`
Muskogee Crape Myrtle
45 gal., 7` ht. x 42" sprd., 3" cal.
As shown
Standard
MG
10
Magnolia grandiflora
Southern Magnolia
45 gal., 8` ht. x 54" sprd., 3" cal.
As shown
Full to ground
PD
23
Pinus elliotti densa
Slash Pine
45 gal., 8` ht., 28" sprd., 3" cal.
As shown
QV
6
Quercus virginiana
Southern Live Oak
100 gal., 10` ht. x 6` sprd., 4" cal.
As shown
TC
13
Tabebuia chrysotricha
Golden Trumpet Tree
45 gal., 7` ht. x 42" sprd., 3" cal.
As shown
TD
65
Taxodium distichum
Bald Cypress
45 gal., 8` ht., 28" sprd., 3" cal.
As shown
PALMS SP
QTY 30
BOTANICAL NAME Sabal palmetto
COMMON NAME Cabbage Palmetto
SHRUBS CR
QTY 235
BOTANICAL NAME Chrysobalanus icaco 'Red Tip'
COMMON NAME Red Tip Cocoplum
MC
389
Muhlenbergia capillaris
PMP
106
RE
E
TB
E
SEAL:
PROPOSED TREE
TB
TB TB
TB
D
C
UNIVERSITY LN
UNIVERSITY LANE
B
A
SIZE * Height as shown, 12" min. cal. at 4.5` above grade
CLIENT'S NO.:
SPACING As shown
NOTES Regenerated, minimum four fronds
SIZE 3 gal., 24" ht. x 18" sprd.
SPACING 36" o.c.
NOTES
Pink Muhly
3 gal., 24" ht. x 18" sprd.
36" o.c.
Podocarpus macrophyllus 'Pringles'
Pringles Dwarf Podocarpus
3 gal., 24" ht. x 24" sprd.
36" o.c.
72
Russelia equisetiformis
Firecracker Plant
3 gal., 24" ht. x 24" sprd.
36" o.c.
ENHANCED AG
QTY 168
BOTANICAL NAME Agapanthus africanus
COMMON NAME Agapanthus
SIZE 3 gal., 24" ht. x 24" sprd.
SPACING 36" o.c.
CM
201
Carissa macrocarpa
Natal Plum
3 gal., 18" ht. x 18" sprd.
36" o.c.
CN
25
Crinum asiaticum
Crinum Lily
7 gal., 24" ht. x 24" spr.
As shown
IN
294
Ilex vomitoria 'Nana'
Dwarf Yaupon Holly
3 gal., 12" ht. x 12" sprd.
30" o.c.
ND
162
Nerium oleander 'Dwarf'
Dwarf Oleander
3 gal., 24" ht. x 24" sprd.
36" o.c.
RO
105
Rosmarinus officinalis
Rosemary
3 gal., 24" ht. x 18" sprd.
36" o.c.
TF
451
Tripsacum floridanum
Florida Gamagrass
3 gal., 24" ht. x 18" sprd.
36" o.c.
ZF
31
Zamia furfuracea
Cardboard Palm
3 gal., 18" ht. x 18" sprd.
48" o.c.
ENHANCED EB
QTY 241
BOTANICAL NAME Evolvulus glomeratus `Blue Daze`
COMMON NAME Blue Daze Morning Glory
SIZE 1 gal., 6" ht. x 12" sprd.
SPACING 30" o.c.
GP
275
Gaillardia pulchella
Indian Blanketflower
1 gal., 12" ht. x 18" sprd.
30" o.c.
HD
413
Helianthus debilis
Dune Sunflower
1 gal., 12" ht. x 18" sprd.
30" o.c.
JB
283
Juniperus conferta `Blue Pacific`
Blue Pacific Juniper
1 gal., 6" ht. x 12" sprd.
30" o.c.
SOD/SEED SEED
QTY 7,819 sf
BOTANICAL NAME Paspalum notatum `Argentine`
COMMON NAME Argentine Bahia Grass
SIZE Seed
SPACING
SOD
235,221
Paspalum notatum `Argentine`
Argentine Bahia Grass
sod
2
3
4
5
6
7
ISSUED FOR:
BID
ISSUED DATE:
13 APR 2022
D
REVISIONS:
NOTES C
SCALE:
0
15'
60'
NOTES SHEET TITLE:
LANDSCAPE PLAN AND SCHEDULE NOTES Clean and dry seed Sand grown and weed free
A SHEET NUMBER:
L-102 8
30'
SCALE: 1" = 30'
B
* Sabal Palms to be 8', 12', 16', and 20' clear trunk heights. Cluster in groups of staggered heights
1
21-086
PROJECT NO:
9
10
2
4
3
5
NOTE: 1. ENSURE PLANTING PIT DRAINS WELL PRIOR TO INSTALLATION. 2. REMOVE TREE FROM CONTAINER OR REMOVE UPPER 1/3 OF BURLAP AND WIRE MESH FOR B&B TREES. 3. SLICE ROOTBALL VERTICALLY ON OUTSIDE EDGES OF AND AROUND ROOTBALL. 4. TREE TO BE PLUMB. STAKE TREE IF NEEDED. SUBMIT TREE STAKING DETAILS AND LAYOUT FOR APPROVAL.
TOP OF ROOTBALL 1-2" ABOVE FINISH GRADE
I
MULCH, 3" THICKNESS TYPICAL AND ONLY 1" OVER ROOTBALL 3" - 6" SOIL BERM TO OUTSIDE OF ROOTBALL FINISH GRADE
CL LOOSEN SIDE SLOPES OF PLANTING PIT
EQUAL
TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. ROOTBALL SITS ON BOTTOM OF PLANTING PIT
EQUAL
2 x 4 x 12, TYP. BATTEN (2) 1" NYLON STRAPS CUT BRACE TO BE FLUSH WITH BATTEN AND ATTACH WITH SCREWS (3) 2 x 4 BRACES, VERTICAL, AND EVENLY SPACED AROUND TRUNK
CL
SCARIFY SIDE SLOPES
ROOTBALL ON EXISTING SOIL
ER NT G CE ON PACIN S
12" OFFSET FOR GROUNDCOVERS 18" OFFSET FOR SHRUBS
SOUTH 1 Tree / 50 LF
EQUAL
360
Mitigation inches defecit
138
Mitigation inches defecit
2023
Mitigation inches converted to 4" trees
35
Mitigation inches converted to 3" trees
674
Arbor Mitigation Fund Contribution preliminary total
Perimeter (LF)
Trees Required
PROVIDED
332
6.6
8 trees
Perimeter (LF)
Trees Required
PROVIDED
NORTH 1 Tree / 50 LF
390
7.8
8 trees
EAST 1 Tree / 50 LF
584
11.7
12 trees
REQUIREMENT
SHRUB AND GROUNDCOVER LAYOUT DETAIL
Per Cocoa, FL Code of Ordinances, Part II- Code, Appendix A- Zoning, Article XIII.Supplementary District Regulations. Sec. 22.- Landscape requirements (C) (5) Perimeter landscaping adjacent to abutting commercial properties. One tree between the common lot line and the off-street parking for each fifty linear feet of lot depth. Each tree shall be planted in at least twenty-five square foot planting area with a minimum dimensions of at least five feet.
C
REQUIREMENT 1 Tree / 50 LF
Perimeter (LF)
Trees Required
PROVIDED
230
4.6
14 trees along E perimeter parking area
INTERIOR PARKING AREA LANDSCAPING
Per Cocoa, FL Code of Ordinances, Part II- Code, Appendix A- Zoning, Article XIII.Supplementary District Regulations. Sec. 22.- Landscape requirements (C) (6) Interior parking area landscaping. Off-street parking areas and other vehicular use areas shall have at least ten square feet of interior landscaping for each parking space excluding those spaces abutting a perimeter for which landscaping is required. Each separate landscaped area shall contain at least one tree with the remaining area adequately landscaped groundcover or other authorized landscaping material.The total number of trees shall not be less than one for each one hundred square feet or fraction thereof of required interior landscaped area.
B
Total # interior parking spaces
105
Landscape area required (SF)
1050
Landscape area provided (SF)
3664
Minimum # trees
10.5
Trees provided
A
4
Certificate of Authorization No. LC26000575
$35,271
PROJECT NAME:
$290,580
I
6
$325,851
H
2.
PLANTING PREPARATION: REMOVE ALL CONSTRUCTION DEBRIS, LIMEROCK, GRAVEL, ROAD BEDDING, LITTER, AND OTHER ITEMS POTENTIALLY DAMAGING TO PLANT GROWTH WITHIN PROPOSED LANDSCAPE AND TURF AREAS PRIOR TO PLANTING. MAINTAIN EXISTING GRADES UNLESS OTHERWISE APPROVED BY THE OWNER'S REPRESENTATIVE. IF FILL IS REQUIRED, USE A CLEAN, SANDY LOAM WITH pH 5.5-6.5 AND EXCAVATED FROM LOCAL SOURCES AND DEEP PITS SUCH THAT IT IS FREE OF WEEDS, SEEDS, LITTER, TOXINS, AND OTHER ITEMS HARMFUL TO PLANTINGS.
3.
PRUNING: IF TREE OR ROOT PRUNING IS REQUIRED, THESE ACTIVITIES SHALL BE PERFORMED BY AN ARBORIST CERTIFIED BY THE INTERNATIONAL SOCIETY OF ARBORICULTURE (ISA). TREE PRUNING SHALL BE DONE IN ACCORDANCE WITH THE MOST CURRENT VERSION OF THE AMERICAN NATIONAL STANDARD FOR TREE CARE OPERATIONS "TREE. SHRUB AND OTHER WOODY PLANT MAINTENANCE" (ANSI 300) AND "PRUNING. TRIMMING. REPAIRING. MAINTAINING, AND REMOVING TREES. AND CUTTING BRUSH—SAFETY REQUIREMENTS" (ANSI Z133). NO MORE THAN 25 PERCENT OF THE CROWN SHOULD BE REMOVED AT ONE TIME. ON YOUNG TREES, LIMB REMOVAL SHALL LEAVE NO MORE THAN 33 PERCENT OF THE TRUNK BARE OF BRANCHES. MINIMIZE IMPACTS ON EXISTING TREE ROOTS AS MUCH AS POSSIBLE. AVOID TREE ROOT PLATE AREAS AS DEFINED BY PERMITTING AGENCIES. ALL ROOTS OF TREES TO REMAIN THAT ARE ADJACENT TO EXTENSIVE EXCAVATION AND ARE 1” DIAMETER OR OVER SHALL BE HAND CUT. EXPOSE ROOTS BY HAND DIGGING, HAND CUT OR SAW CLEANLY, AND IMMEDIATELY COVER WITH SOIL. DO NOT ALLOW CUT ROOTS TO DRY OUT. SUPPLEMENTAL IRRIGATION IS REQUIRED FOR TREES THAT HAVE UNDERGONE ROOT PRUNING AND SHALL BE PROVIDED IMMEDIATELY FOLLOWING ROOT TRIMMING ACTIVITIES.
7
Cocoa, FL
for
HTG Orchid Lake, Ltd. G
PLANT MATERIAL, GENERAL: ALL PLANT MATERIALS SHALL MEET 'FLORIDA NUMBER 1' REQUIREMENTS AS PER THE MOST CURRENT EDITION OF 'FLORIDA GRADES AND STANDARDS FOR NURSERY PLANTS', FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. GRASS SOD SHALL BE CLEAN AND REASONABLY FREE OF WEEDS AND NOXIOUS PESTS OR DISEASES.
5.
PROPOSED TREES: PROPOSED TREES SHALL BE A MINIMUM OF SIX FEET TALL. TREES OF SPECIES WHOSE ROOTS ARE KNOWN TO CAUSE DAMAGE TO PUBLIC ROADWAYS OR OTHER PUBLIC WORKS SHALL NOT BE PLANTED CLOSER THAN TWENTY (20) FEET TO SUCH PUBLIC WORKS.
6.
NEW TREE STAKING: IF NECESSARY TO MAINTAIN TREES PLUMB, TREES SHALL BE STAKED WITH BIODEGRADABLE STAKING MATERIALS.
7.
PROPOSED SHRUBS: PROPOSED SHRUBS SHALL BE A MINIMUM OF TWO FEET TALL.
8.
TURF: ALL UNPAVED AND DISTURBED AREAS OUTSIDE OF PROPOSED TREE, SHRUB, AND GROUNDCOVER PLANTINGS SHALL BE GRASSED. SEE CIVIL PLANS FOR GRASSING INFORMATION FOR STORMWATER FACILITIES. SOD SHALL BE SAND-GROWN, STRONGLY ROOTED, WITHOUT SYNTHETIC STABILIZING MATERIALS, FREE OF PESTS, AND CERTIFIED FREE OF NOXIOUS WEEDS BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES, DIVISION OF PLANT INDUSTRY. SEE PLAN FOR PROPOSED SOD AREAS, WHICH SHALL INCLUDE AT A MINIMUM A 3' STRIP ALONG ALL PAVING EDGES AND BUILDING PERIMETERS, ANY SLOPES 4:1 OR GREATER, AND ANY STORMWATER, SWALE, OR OTHER AREAS SUBJECT TO EROSION. SEE TECHNICAL SPECIFICATIONS FOR ADDITIONAL SOD AND SEED REQUIREMENTS.
9.
MULCHING: THREE INCHES OF MULCH, SETTLED, SHOULD COVER TREE RING PLANTING AREAS AND ALL SHRUB AND GROUNDCOVER PLANTING AREAS. MULCH SHOULD BE NO DEEPER THAN ONE INCH OVER THE TOP OF TREE ROOTBALLS. USE PINESTRAW MULCH IN ALL AREAS. MULCH TO BE FREE OF DEBRIS, STICKS, AND CONES. NO PLASTIC OR NON-BIODEGRADABLE WEED CLOTH OR SURFACE COVERS TO BE USED.
10.
COMPLIANCE: NO CERTIFICATE OF OCCUPANCY SHALL BE ISSUED UNTIL THE LANDSCAPING IS COMPLETE AND IT SHALL BE UNLAWFUL TO OCCUPY THE PREMISES UNLESS THE LANDSCAPE PLAN HAS BEEN APPROVED, COMPLIED WITH, AND RECEIVED A FINAL INSPECTION FROM THE ENFORCEMENT OFFICIAL.
11.
MAINTENANCE: THE OWNER SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL LANDSCAPING WHICH SHALL BE SO MAINTAINED AS TO PRESENT A NEAT AND ORDERLY APPEARANCE AND SHALL BE KEPT FREE FROM REFUSE AND DEBRIS. ALL LANDSCAPED AREAS SHALL BE PROVIDED WITH A READILY AVAILABLE WATER SUPPLY WITH AT LEAST ONE (1) OUTLET LOCATED WITHIN ONE HUNDRED (100) FEET OF ALL PLANT MATERIAL TO BE MAINTAINED. IT SHALL BE THE DUTY OF THE PROPERTY OWNER TO PROVIDE PROPER MAINTENANCE OF THE LANDSCAPE PLANTINGS INSTALLED AT ALL TIMES. THIS INCLUDES, BUT IS NOT LIMITED TO, THE REPLACEMENT OF PLANTS DAMAGED BY INSECTS, DISEASES, VEHICULAR TRAFFIC, ACTS OF GOD, OR VANDALISM, THAT ARE BEYOND A REASONABLE EXPECTATION OF RECOVERY. NECESSARY REPLACEMENTS SHALL BE MADE WITHIN NINETY (90) DAYS OF NOTIFICATION BY THE ENFORCEMENT OFFICIAL. IN NO CASE SHALL GRASS CLIPPINGS, VEGETATIVE MATERIAL, AND/OR VEGETATIVE DEBRIS BE WASHED, SWEPT, OR BLOWN OFF INTO SURFACE WATERS, STORMWATER DRAINS, DITCHES, CONVEYANCES, WATERCOURSES, WATER BODIES, WETLANDS, SIDEWALKS, OR ROADWAYS. ANY MATERIAL THAT IS ACCIDENTALLY SO DEPOSITED SHALL BE IMMEDIATELY REMOVED TO THE MAXIMUM EXTENT PRACTICABLE.
12.
FERTILIZER: FOLLOW CITY OF COCOA REQUIREMENTS AS LISTED BELOW:
x
NO APPLICATOR SHALL APPLY FERTILIZERS CONTAINING NITROGEN AND/OR PHOSPHOROUS TO TURF AND/OR LANDSCAPE PLANTS DURING THE PROHIBITED APPLICATION PERIOD, OR TO SATURATED SOILS. IN ADDITION, FERTILIZER CONTAINING NITROGEN OR PHOSPHOROUS SHALL NOT BE APPLIED TO TURF OR LANDSCAPE PLANTS DURING THE RESTRICTED APPLICATION PERIOD, DEFINED AS JUNE 1 TO SEPTEMBER 30. FERTILIZER SHALL NOT BE APPLIED WITHIN TEN (10) FEET OF ANY SURFACE WATERS, POND, STREAM, WATERCOURSE, LAKE, CANAL, OR WETLAND AS DEFINED BY THE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION (CHAPTER 62-340, FLORIDA ADMINISTRATIVE CODE). NEWLY PLANTED TURF AND/OR LANDSCAPE PLANTS MAY BE FERTILIZED IN THIS ZONE FOR A SIXTY-DAY PERIOD BEGINNING THIRTY (30) DAYS AFTER PLANTING IF NEEDED TO ALLOW THE PLANTS TO BECOME WELL ESTABLISHED. CAUTION SHALL BE USED TO PREVENT DIRECT DEPOSITION OF NUTRIENTS INTO THE WATER. A VOLUNTARY TEN-FOOT LOW MAINTENANCE ZONE IS STRONGLY RECOMMENDED, BUT NOT MANDATED, FROM ANY SURFACE WATERS, POND, STREAM, WATERCOURSE, LAKE, WETLAND OR FROM THE TOP OF A SEAWALL. A SWALE/BERM SYSTEM IS RECOMMENDED FOR INSTALLATION AT THE LANDWARD EDGE OF THIS LOW MAINTENANCE ZONE TO CAPTURE AND FILTER RUNOFF. NO MOWED OR CUT VEGETATIVE MATERIAL SHOULD BE DEPOSITED OR LEFT REMAINING IN THIS ZONE OR DEPOSITED IN THE WATER. CARE SHOULD BE TAKEN TO PREVENT THE OVER-SPRAY OF AQUATIC WEED PRODUCTS IN THIS ZONE.
x
NO FERTILIZER CONTAINING PHOSPHOROUS SHALL BE APPLIED TO TURF OR LANDSCAPE PLANTS IN COCOA UNLESS A SOIL OR PLANT TISSUE DEFICIENCY AS VERIFIED BY A UNIVERSITY OF FLORIDA, INSTITUTE OF FOOD AND AGRICULTURE SCIENCES, APPROVED TESTING METHODOLOGY. IN THE CASE THAT A DEFICIENCY HAS BEEN VERIFIED, THE APPLICATION OF A FERTILIZER CONTAINING PHOSPHOROUS SHALL BE IN ACCORDANCE WITH THE RATES AND DIRECTIONS PROVIDED BY RULE 5E-1.003(2). FLORIDA ADMINISTRATIVE CODE. DEFICIENCY VERIFICATION SHALL BE NO MORE THAN TWO (2) YEARS OLD. HOWEVER, RECENT APPLICATION OF COMPOST MANURE, OR TOP SOIL SHALL WARRANT MORE RECENT TESTING TO VERIFY CURRENT DEFICIENCIES.
x
THE NITROGEN CONTENT OF FERTILIZER APPLIED TO TURF OR LANDSCAPE PLANTS WITHIN COCOA SHALL CONTAIN AT LEAST FIFTY (50) PERCENT SLOW RELEASE NITROGEN PER GUARANTEED ANALYSIS LABEL.
x
FERTILIZERS APPLIED TO TURN WITHIN COCOA SHALL BE APPLIED AT RATES THAT ARE IN ACCORDANCE WITH REQUIREMENTS AND DIRECTIONS PROVIDED BY RULE 5E-1.003(2), FLORIDA ADMINISTRATIVE CODE, LABELING REQUIREMENTS FOR URBAN TURF FERTILIZERS.
x
FERTILIZER CONTAINING NITROGEN OR PHOSPHOROUS SHALL NOT BE APPLIED BEFORE SEEDING OR SODDING A SITE, AND SHALL NOT BE APPLIED FOR THE FIRST THIRTY (30) DAYS AFTER SEEDING OR SODDING, EXCEPT WHEN HYDRO-SEEDING FOR TEMPORARY OR PERMANENT EROSION CONTROL IN AN EMERGENCY SITUATION (WILDFIRE, ETC.), OR IN ACCORDANCE WITH THE STORMWATER POLLUTION PLAN FOR THAT SITE.
x
SPREADER DEFLECTOR SHIELDS ARE REQUIRED WHEN FERTILIZING VIA ROTARY (BROADCAST) SPREADERS. DEFLECTORS MUST BE POSITIONED SUCH THAT FERTILIZER GRANULES ARE DEFLECTED AWAY FROM ANY IMPERVIOUS SURFACES, FERTILIZER-FREE ZONES, SURFACE WATERS AND WATER BODIES, INCLUDING WETLANDS.
x
FERTILIZER SHALL NOT BE APPLIED, SPILLED, OR OTHERWISE DEPOSITED ON ANY IMPERVIOUS SURFACES. ANY FERTILIZER APPLIED, SPILLED, OR DEPOSITED, EITHER INTENTIONALLY OR ACCIDENTALLY, ON ANY IMPERVIOUS SURFACE SHALL BE IMMEDIATELY AND COMPLETELY REMOVED TO THE GREATEST EXTENT PRACTICABLE AND EITHER LEGALLY APPLIED TO TURF OR ANY OTHER LEGAL SITE, OR RETURNED TO THE ORIGINAL OR OTHER APPROPRIATE CONTAINER. IN NO CASE SHALL FERTILIZER BE WASHED, SWEPT, OR BLOWN OFF IMPERVIOUS SURFACES INTO STORMWATER DRAINS, DITCHES, CONVEYANCES, OR WATER BODIES.
x
11
5
ORCHID LAKE
EXISTING UTILITIES: LOCATE ALL UTILITIES PRIOR TO COMMENCEMENT OF WORK. CALL SUNSHINE STATE ONE CALL - SEE LOGO.
x
PERIMETER LANDSCAPING ADJACENT TO ABUTTING COMMERCIAL PROPERTIES
SCALE: N.T.S
Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412
1.
4.
Per Cocoa, FL Code of Ordinances, Part II- Code, Appendix A- Zoning, Article XIII.Supplementary District Regulations. Sec. 22.- Landscape requirements (C) (4) Required landscaping adjacent to public rights-of-way. A landscaped strip at least five feet in width between the abutting right-of-way and the off-street parking area, including one tree for each fifty linear feet or fraction thereof, located between the abutting right-of-way and off-street parking area in a planting area of at least twenty-five square feet with a dimension of at least five feet, and a hedge of at least two feet in height along the perimeter of such landscaped strip. Provided: Hedge, see plans. See below for tree calculations.
TRIANGULAR LAYOUT, TYPICAL, IN STRAIGHT RUNS AND AS MUCH AS POSSIBLE AROUND CURVES. ON CENTER SPACING DISTANCE SHALL BE AS INDICATED IN SCHEDULE.
3
Total inches of proposed 12" palms as shown in plan
REQUIRED LANDSCAPING ADJACENT TO PUBLIC RIGHTS-OF-WAY
ON CENTER SPACING
BEDLINE OR PAVING EDGE
2
24
J
LANDSCAPE NOTES
LOOSEN SIDE SLOPES OF PLANTING PIT TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. ROOTBALL SITS ON BOTTOM OF PLANTING PIT
Per Cocoa, FL Code of Ordinances, Part II- Code, Appendix A- Zoning, Article XIII.Supplementary District Regulations. Sec. 22.- Landscape requirements (C) Landscaping requirements for certain yard areas and off-street parking and other vehicular use areas. A landscaped strip of land at least five (5) feet in width shall be provided between the abutting right-of-way and the off-street parking area, including one tree for each fifty linear feet or fraction thereof, located between the abutting right-of-way and off-street parking area, planted in a planting area of at least twenty-five square feet with a dimension of at least five feet; and a hedge of at least two feet in height along the perimeter of such landscaped strip. Provided: Hedge, see plans. See below for tree calculations.
OUTSIDE ROW FOLLOWS CURVE AS SHOWN. ROWS REMAIN PARALLEL AROUND CURVE.
1
Total inches of proposed 4" trees as shown in plan
Site Planning
This preliminary mitigation cost is based on unit costs per 3" or 4" replacement tree as listed above, which include plant material, delivery, installation, and two years of maintenance. Please refer to the 'Request for Contribution to the Arbor Mitigation Fund' memo dated April 1, 2022. Further discussion of the final mitigation payment is respectfully requested given that this project is a deed-restricted affordable housing development.
LANDSCAPING REQUIREMENTS FOR OFF-STREET PARKING AND VEHICULAR USE AREAS
TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL.
REQUIREMENT
4
672
PLANTING DETAIL 2 PALM SCALE: N.T.S.
AND GROUNDCOVER PLANTING DETAIL 3 SHRUB SCALE: N.T.S
D
Total inches of proposed 3" trees as shown in plan
Arbor Mitigation Fund Contribution - preliminary total
The following calclations are per Cocoa, FL, Code of Ordinances, Part II- Code, Appendix A- Zoning, Article XIII.- Supplementary District Regulations. Sec. 22.- Landscape requirements (C) Landscaping requirements for certain yard areas and off-street parking and other vehicular use areas
E
162
Landscape Architecture
TOTAL REQUIRED MITIGATION
BRACE NAILED TO 2 x 4 WOOD STAKE WITH TOP BELOW GRADE
2 X ROOTBALL WIDTH
3 X ROOTBALL DIMENSION
Mitigation inches required - to be replaced with 4" caliper trees minimum
Arbor Mitigation Fund Contribution preliminary total
LANDSCAPE CALCULATIONS
F
3055
FINISH GRADE
SCALE: N.T.S
CUT INTO GRADE AT EDGE OF BED SUCH THAT MULCH SURFACE MEETS FINISH GRADE.
Mitigation inches required - to be replaced with 3" caliper trees minimum
3" - 6" SOIL BERM TO OUTSIDE OF ROOTBALL
EQUAL
FINISH GRADE
G
10
REQUIRED MITIGATION - 4" MINIMUM REPLACEMENT TREES
MULCH, 4" THICKNESS TYPICAL AND ONLY 1" OVER ROOTBALL
TREE PLANTING DETAIL MULCH, 3" THICKNESS TYPICAL. 1" MAXIMUM OVER ROOTBALL. SOIL BERM TO OUTSIDE OF ROOTBALL.
9
REQUIRED MITIGATION- 3" MINIMUM REPLACEMENT TREES
TOP OF ROOTBALL 1-2" ABOVE FINISH GRADE
2 X ROOTBALL WIDTH
1
8
SAFETY FLAG AT MIDPOINT
30" MIN. DEPTH
H
(5) LAYERS OF BURLAP
NOTE: SUBMIT SHOP DRAWINGS FOR STAKING LAYOUT AND DETAILS.
CLEAR TRUNK HEIGHT
J
7
6
1/3 TRUNK HEIGHT, MINIMUM
1
ALL COMMERCIAL AND INSTITUTIONAL APPLICATORS OF FERTILIZER WITHIN CITY OF COCOA SHALL ABIDE BY AND SUCCESSFULLY COMPLETE THE SIX-HOUR TRAINING PROGRAM IN THE "FLORIDA-FRIENDLY BEST MANAGEMENT PRACTICES FOR PROTECTION OF WATER RESOURCES BY THE GREEN INDUSTRIES" OFFERED BY THE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION THROUGH THE UNIVERSITY OF FLORIDA EXTENSION "FLORIDA-FRIENDLY LANDSCAPES" PROGRAM, OR AN APPROVED EQUIVALENT. PRIVATE, NON-COMMERCIAL APPLICATORS ARE ENCOURAGED TO FOLLOW THE RECOMMENDATIONS OF THE UNIVERSITY OF FLORIDA IFAS FLORIDA YARDS AND NEIGHBORHOODS PROGRAM WHEN APPLYING FERTILIZERS. ALL COMMERCIAL APPLICATORS OF FERTILIZER WITHIN THE CITY OF COCOA SHALL HAVE AND CARRY IN THEIR POSSESSION AT ALL TIMES WHEN APPLYING FERTILIZER, EVIDENCE OF CERTIFICATION BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES AS A COMMERCIAL FERTILIZER APPLICATOR PURSUANT TO RULE 5E-14.117(18), FLORIDA ADMINISTRATIVE CODE. INSTITUTIONAL APPLICATORS WHO APPLY FERTILIZER TO TURF AND/OR LANDSCAPE PLANTS (INCLUDING BUT NOT LIMITED TO RESIDENTIAL LAWNS, GOLF COURSES, COMMERCIAL PROPERTIES, AND MULTI-FAMILY AND CONDOMINIUM PROPERTIES) MUST ENSURE THAT AT LEAST ONE EMPLOYEE HAS A "FLORIDA-FRIENDLY BEST MANAGEMENT PRACTICES FOR PROTECTION OF WATER RESOURCES BY THE GREEN INDUSTRIES" TRAINING CERTIFICATE PRIOR TO THE BUSINESS OWNER OBTAINING A BUSINESS TAX RECEIPT. OWNERS FOR ANY CATEGORY OF OCCUPATION WHICH MAY APPLY ANY FERTILIZER TO TURF AND/OR LANDSCAPE PLANTS SHALL PROVIDE PROOF OF COMPLETION OF THE PROGRAM TO THE CITY OF COCOA'S BUILDING DEPARTMENT
8
9
10
SEAL:
F
E
PROJECT NO:
21-086
CLIENT'S NO.: ISSUED FOR:
BID
ISSUED DATE:
13 APR 2022
D
REVISIONS:
C
SCALE:
AS NOTED B
SHEET TITLE:
LANDSCAPE NOTES, DETAILS AND CALCULATIONS A SHEET NUMBER:
L-103
UP
81.40
82.77
OW
OW
OW
OW
SDO
OW
OW
8" PVC
UP
S
79.35
SF 83.27
5' CW
OW
79.24
D
D
D
SDO
8" PVC
TB
SF
EXISTING TREES AND
75
VEGETATION TO REMAIN
SF
24
SF
P-6
Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412
EXISTING TREE TO BE REMOVED
Certificate of Authorization No. LC26000575
0.5'E
SF
SILT FENCE SEE CIVIL PLANS, TYP.
PROJECT NAME:
#
82.08
Site Planning
J
4' WF
UTILITY ESMT 13 ORB 2508, PG 1284
81.97
76.15 76.58 76.75 76.82 76.93 OW 76.75 O
Landscape Architecture
SF
TB
124
82.15
OW 82.21
OW
83.23
D
D
D
D
6.3'
83.10
P-5
87.17
TB
#
OW
RCP
D
O
SW 147TH DR
3.1'
TB
36 0.4'W
OW
UP
85.01
N89°11'07"E 1001.81'
89.73
OW
D
78.59 78.94 79.07 D 79.12
MANLEY DESIGN
LEGEND
TOP=78.85 N. INV=69.80 E. INV=69.75
P-9
OW
24" RCP 82.13
D
EP
P-8
OW
24" RCP
89.83
35
85.92
D
D
85.99 OW
82.99 D 83.04
D
D
P-7
4' BARBED WIRE FENCE
85.39
85.58
86.07
86.37
D 86.90 86.58 87.04 OW 86.78 T 87.23 87.11 87.29 88.46 87.59
87.04 87.20
24" RCP D 5' CW
81.50
87.24 87.14
OW
D
10
O
37
D
D
UP
D
89.56
89.20
OW
OW
85.73
85.97
80.71 81.17 D 81.21 81.39 OW 81.47
SF
UP
UP
D
OW
86.30 D
81.40 81.89 24" 81.99 D 82.02 82.03 OW
SF
89.73
OW
OW
OW
OW
D
D
86.82
81.62
82.53
84.28 84.76 84.85 D 84.97 85.10OW
SF
OW
OW
24" RCP
D
D
D
D
D
24" RCP
NEWBERRY ROAD / SR 26
85.30
ASPHALT
DRMP TEST HOLE # EH-3 ELEV=80.77
SF
OW
OW
OW
89.34
89.55
88.40 88.43 D 88.62 88.69 OW 88.86
85.86
TOP=82.08 N. INV=76.88 E. INV=76.33 W. INV=76.38
SF
89.58
5' CW
86.41
87.97
TOP=85.93 N. INV=80.98 E. INV=80.88 W. INV=80.83
79.27
81.45
81.99
83.28
2' CURB & GUTTER (TYP)
SF
89.25 OW
UP
D
D
D
89.31
85.09
86.47
SF
SDO 89.15
89.03 D89.41
6 .9 86.87 86
SF
2' CURB & GUTTER (TYP)
88.65 88.63
OW
EP
87.46
9
SF
ASPHALT
J
88. 00
88.22
OW
TOP=88.98 N. INV=83.98 E. INV=82.88 W. INV=82.83
EP
88.22
8
SF
89.82
88.82
7
6
SF
OW
89.43
89.30 88.79
5
SF
90.31
89.91
89.23
4
3
SF
2
S
1
121 SF
TB
SF SF SF
SF SF SF O
33
SF
#
30
82.33
TB
81.76
SF
H
79.96
Alachua County, FL
#
SF
P-15
SW 1ST PL
TB
32
83.18
87.90
P-2
IRRIGATION VALVE
P-14
TB
H
O
TB
29 31 IRRIGATION CONTROL BOX
LAUREATE VILLAGE TND Phase 2, Unit 2
SF
88.34
88.29
P-13
#
TB
P-1
TB
87.77
6' WF 4' BARBED WIRE FENCE
80.35 80.11
P-12
#
122
123
I 73.66
O
TB
34
P-11
TB
EXISTING TREE TO REMAIN, TYP. EXISTING TREE CANOPY TO REMAIN, TYP. SPECIALTY TREE BARRICADE - SEE SHEET LS-1, DETAIL 2
P-10
88.13
TB
4' WIRE FENCE
O
CRUSHED RECYCLED CONCRETE PATHS - SEE DETAIL 5/LS-6.
TB
I
SF
L
SF
TB
P-16
O
W
TB
125
80.48 L
#
SF
O
SF SF SF SF SF SF
SF SF
P-21 P-20
SF
#
P-19
SF
P-4
79.36
O
80.34 78.03
P-22
TB
TB
78.95
F
SF
25 #
F
81.92
81.13
80.07
SEAL:
O
128
TB
#
80.11
127
TB
83.59
P-18
P-17
WL
TB
26
O
TB TB
126
G
SF
#
WL
TB TB
27 83.63
HKP Development
O
TB TB
P-3
82.32
SW 147TH TER
#
WL
TB
TREE REMOVALS AND MITIGATION FOR THIS PARCEL CALCULATED BY OTHERS
86.31
for
74.79
SF
TB
81.32
28
G
SF
W
85.35
TB
TYPICAL TREE BARRICADE 85.79 SEE SHEET LS-1, DETAIL 1
O
#
P-23
81.45
SF
O
SW 2ND LN
SF
P-24
SF
SF
81.91
81.07
79.62
79.04
SF SF
SF
82.13
81.27
23
O
P-25
#
SF
24
82.58 #
SF SF SF
SF
S02°45'46"W 1265.84'
SF SF
P-26
SF SF SF
CLIENT'S NO.:
SF 84.90
SF
MATCHLINE SHEET LS-1 86.98
85.61
NOTE:
5.
PRUNING: IF TREE OR ROOT PRUNING IS REQUIRED, THESE ACTIVITIES SHALL BE PERFORMED BY AN ARBORIST CERTIFIED BY THE INTERNATIONAL SOCIETY OF ARBORICULTURE (ISA). TREE PRUNING SHALL BE DONE IN ACCORDANCE WITH THE MOST CURRENT VERSION OF THE AMERICAN NATIONAL STANDARD FOR TREE CARE OPERATIONS "TREE. SHRUB AND OTHER WOODY PLANT MAINTENANCE" ANSI 300) AND "PRUNING. TRIMMING. REPAIRING. MAINTAINING, AND REMOVING TREES. AND CUTTING BRUSH—SAFETY REQUIREMENTS" (ANSI Z133). NO MORE THAN 25 PERCENT OF THE CROWN SHOULD BE REMOVED AT ONE TIME. ON YOUNG TREES, LIMB REMOVAL SHALL LEAVE NO MORE THAN 33 PERCENT OF THE TRUNK BARE OF BRANCHES.
6.
1.
UTILIZE THIS DETAIL FOR ALL EXISTING, HIGH QUALITY TREES THAT ARE 20" DBH AND LARGER.
2.
PRESERVE EACH REGULATED TREE AND ASSOCIATED NATIVE VEGETATION WITHIN THE AREA OF THE DRIPLINE IN ITS ORIGINAL LOCATION.
12'-0" MAXIMUM
3.
4.
WOOD POSTS OR ANGLE IRON FENCE POSTS , TYP.
5.
FINISH GRADE
6.
7.
1
EXISTING UTILITIES: LOCATE ALL UTILITIES PRIOR TO COMMENCEMENT OF WORK. CALL SUNSHINE STATE ONE CALL.
3.
DO NOT STORE MATERIALS OR ALLOW ENCROACHMENT OF VEHICLES OR MACHINERY WITHIN TREE BARRIER AREA. NO BUILDING MATERIALS, FILL, MACHINERY OR HARMFUL CHEMICALS SHALL BE PLACED WITHIN PROTECTIVE BARRIERS.
CHAIN-LINK FENCING, 11-GAUGE AND 2" MESH SIZE
4.
1-7/8" DIA. METAL LINE POSTS, TYP. 10'-0" MAXIMUM
NO GRADE CHANGES MAY OCCUR WITHIN TREE BARRIER AREA WITHOUT APPROVAL.
TREE BARRICADE TO CANOPY DRIPLINE 2-3/8" DIA. METAL CORNER POSTS , TYP.
NO ATTACHMENTS OR WIRES OTHER THAN THOSE OF A PROTECTIVE AND NON-DAMAGING NATURE MAY BE ATTACHED TO ANY TREE.
8" THICK LAYER OF WOOD CHIPS TO COVER AREA WITHIN TREE BARRIER FINISH GRADE
LANDSCAPE PREPARATION IN THE UNDISTURBED AREA SHALL BE PROHIBITED UNLESS SPECIFICALLY APPROVED OTHERWISE BY THE COUNTY. LANDSCAPING SHALL BE LIMITED TO PLACEMENT OF SOD, MULCH, OR OTHER GROUND COVERS.
4'-0" DEPTH CORNER POSTS
ON-SITE LITTER REMOVAL: REMOVE ALL EXISTING LITTER AND DEBRIS VISIBLE ON THE PROJECT SITE.
BRIGHTLY COLORED MESH CONSTRUCTION FENCING
TREE BARRICADE TO CANOPY DRIPLINE UNLESS OTHERWISE APPROVED BY COUNTY FORESTER/ LANDSCAPE INSPECTOR
CONTACT THE ALACHUA COUNTY FORESTER/LANDSCAPING INSPECTOR AT (352) 374-5243 EXT. 3503 FOR A TREE BARRICADE INSPECTION PRIOR TO COMMENCEMENT OF CONSTRUCTION.
3'-0" DEPTH LINE POSTS
INVASIVE SPECIES: REMOVE INVASIVE, NONNATIVE PLANT SPECIES AS LISTED ON THE FLORIDA PROHIBITED AQUATIC PLANTS LIST OR THE FLORIDA NOXIOUS WEED LIST FROM THE SITE PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. ALL HERBICIDE APPLICATIONS TO CONTROL INVASIVE, NONNATIVE PLANTS IN WETLAND OR UPLAND SET-ASIDE AREAS, INCLUDING BUFFERS, SHALL BE APPLIED BY A CONTRACTOR LICENSED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES, DIVISION OF AGRICULTURAL ENVIRONMENTAL SERVICES, WITH A CURRENT CERTIFICATION IN NATURAL AREAS WEED MANAGEMENT.
4.
A
2.
PRESERVE EACH REGULATED TREE AND ASSOCIATED NATIVE VEGETATION WITHIN THE AREA OF THE DRIPLINE IN ITS ORIGINAL LOCATION.
4'-0" HEIGHT BARRIER FENCING
B
1.
DEPTH TO PROVIDE CONTINUED STABILITY
3.
PRE-CONSTRUCTION MEETING: COORDINATE AND CONDUCT AN ON-SITE MEETING WITH THE ALACHUA COUNTY FORESTER/LANDSCAPE INSPECTOR OR DESIGNATED COUNTY REPRESENTATIVE TO DISCUSS EXISTING REGULATED TREES AND PROTECTION METHODS. CONTACT: (352) 374-5243 EXT. 3503.
REVISIONS:
06 DEC 2021
NOTE:
EXISTING TREE PROTECTION: PROTECTIVE BARRIERS SHALL BE INSTALLED OUTSIDE THE PROTECTED AREA OF RETAINED TREES AND NATIVE VEGETATION TO PREVENT THE COMPACTION OF SOIL AND THE DESTRUCTION OR DAMAGE OF THE TREES. SEE DETAIL 1 & 2 / SHEET LS-1. PROTECTED TREES SHALL INCLUDE THOSE TREES THAT HAVE NOT BEEN PERMITTED NOR DESIGNATED FOR REMOVAL BY EITHER THE TERMS OF THE PERMIT OR APPROVED DEVELOPMENT ORDER. PROTECTIVE BARRIERS SHALL BE PLAINLY VISIBLE AND SHALL CREATE A CONTINUOUS BOUNDARY AROUND TREES OR VEGETATION CLUSTERS IN ORDER TO PREVENT ENCROACHMENT BY MACHINERY, VEHICLES, OR STORED MATERIALS. BARRIERS SHALL BE INSPECTED BY THE COUNTY FORESTER/LANDSCAPE INSPECTOR PRIOR TO PROCEEDING WITH SITE WORK. PROTECTIVE BARRIERS SHALL REMAIN IN PLACE AND INTACT UNTIL CONSTRUCTION IS COMPLETED. PRESERVE EACH REGULATED TREE AND ASSOCIATED NATIVE VEGETATION WITHIN THE AREA OF THE DRIPLINE IN ITS ORIGINAL LOCATION.
04 OCT 2021
80.63
80.13
NORTH
MATCHLINE SHEET LS-2
3'-0" HEIGHT BARRIER FENCING
2.
ISSUED DATE:
6' WF
TREE PRESERVATION AND REMOVAL NOTES
C
DEVELOPMENT PLAN REVIEW
D 80.87
SF
81.53
4' BARBED WIRE FENCE
1.
ISSUED FOR:
O
#
85.33
86.93
SF
16 15
21-048
PROJECT NO:
O
#
17
P-28
18
BUILDING #9
19
82.08
O
#
20
BUILDING #11
#
21
E
O
N02°45'30"E 1265.07'
82.86
P-27
83.70
D
81.20
SW 148TH DR
E
O
22
TYPICAL TREE PROTECTION DETAIL
2
SCALE: N.T.S.
SPECIALTY TREE PROTECTION DETAIL
C
CONTACT THE ALACHUA COUNTY FORESTER/LANDSCAPING INSPECTOR AT (352) 374-5243 EXT. 3503 FOR A TREE BARRICADE INSPECTION PRIOR TO COMMENCEMENT OF CONSTRUCTION. DO NOT STORE MATERIALS OR ALLOW ENCROACHMENT OF VEHICLES OR MACHINERY WITHIN TREE BARRIER AREA. NO BUILDING MATERIALS, MACHINERY OR HARMFUL CHEMICALS SHALL BE PLACED WITHIN PROTECTIVE BARRIERS, EXCEPT SHORT-DURATION PLACEMENTS OF CLEAN FILL SOIL THAT WILL NOT HARM THE TREE.
5.
NO GRADE CHANGES MAY OCCUR WITHIN TREE BARRIER AREA WITHOUT APPROVAL.
6.
NO ATTACHMENTS OR WIRES OTHER THAN THOSE OF A PROTECTIVE AND NON-DAMAGING NATURE MAY BE ATTACHED TO ANY TREE.
7.
LANDSCAPE PREPARATION IN THE UNDISTURBED AREA SHALL BE PROHIBITED UNLESS SPECIFICALLY APPROVED OTHERWISE BY THE COUNTY. LANDSCAPING SHALL BE LIMITED TO PLACEMENT OF SOD, MULCH, OR OTHER GROUND COVERS.
8.
TREE BARRIERS TO REMAIN IN PLACE UNTIL CONSTRUCTION IS COMPLETED.
TREE BARRIERS TO REMAIN IN PLACE UNTIL CONSTRUCTION IS COMPLETED.
07 MAR 2022 02 MAY 2022
SCALE: N.T.S.
SCALE:
0
20'
2
3
4
5
6
7
8
9
10
80'
SCALE: 1" = 40'
B
SHEET TITLE:
TREE PRESERVATION AND REMOVAL PLAN A SHEET NUMBER:
LS-1 1
40'
2
5
8
9
10
MATCHLINE SHEET LS-1
SF
84.90
80.63
6' WF
SF SF
84.56
P-30
UP
Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412
SF
4' WIRE FENCE
SF
48 46 85.00
SF 83.33
TB
TB
#
TB
SF
SF
TB
TB
TB
TB
TB
TB
E IBL SS CE TABLE AC NIC PIC
TYPICAL TREE BARRICADE - SEE SHEET LS-1, DETAIL 1
84.31
SF SF
106
85.67 WL
86.26
SF
WL
SF
D
SW
PL
3R
88.02
87.79
83.61
82.71
84.32
SF 86.76
for
HKP Development
SF
83.93
87.69
SF
SF
85.15
SF
X#
87.36 88.36
SEAL:
SF
88.21
O
SF
57
83.61
56
G
O
G
84.81
55
88.60
84.47
O
#
52
86.45
87.15
82.85
Alachua County, FL
SF
SW 148TH DR
90.94
SF
SPECIALTY TREE BARRICADE - SEE SHEET86.54 LS-1, DETAIL 2 EXISTING TREE TO REMAIN, TYP.
102
SF
100 101
98 97
83.09
86.28
SF
87.17
103
84.48
SF
99
H
SF
85.84
85.66
SF
96
#
51
EXISTING TREE CANOPY TO REMAIN, TYP.
85.79
O
BUILDING #8
#
45
86.27
86.06
83.79
O
89.44
85.73
BUILDING #10
#
90.55
H
SF
83.92
87.60
O
88.51
53 54
LAUREATE VILLAGE Phase 2, Unit 2
O
104 107
87.70 87.19
TB
105
E IBL SS CE TABLE AC NIC PIC
#
TB
LE
108 89.25
I
O
TAB
#
SF
LE TAB
NIC
WL
WL
4' WIRE FENCE
TB
N02°45'30"E 1265.07'
NIC PIC
PIC
41 42 43 44
84.53
UP
84.85
TB
40
PROJECT NAME:
SF
87.94
O
TB
TB
38
82.06
84.47
SF
TB
Certificate of Authorization No. LC26000575
81.20
TB
TB
39
I
TB
P-32
TB
SF
50
S02°45'46"W 1265.84' 82.93
P-31
#
O
87.92
49
SF
47
Site Planning
O
#
MATCHLINE SHEET LS-2
P-29
86.98
Landscape Architecture
J 4' BARBED WIRE FENCE
85.61
80.13
80.87
MANLEY DESIGN O
#
7
6
SF
85.33
J
4
3
BUILDING #9
1
SF
58 SF
91.05 X
88.39
O
87.05
#
59
87.40
SF
SF
SW 3RD PL
O
F
SF SF
SF
85.02
84.45
SF
0.6'W
4' BARBED WIRE FENCE
6' WF
SF O
87.69
88.37
SF
88.26
0.8'E
WL
91.22
E
SF
X
# 91.86
E
BUILDING #4
BUILDING #6
X
#
67
88.06
85.95
SF
X
#
86.15
SF O 86.17
86.55
O
BUILDING #1
SF
X
SF
#
F
87.28 X
SF
#
SF O
66 65
SF
86.78 88.76
SF
84.28 85.24
O
X
WL
#
64
88.27
SF
SF
21-048
PROJECT NO: CLIENT'S NO.:
SF
63
ISSUED FOR:
DEVELOPMENT PLAN REVIEW
ISSUED DATE:
04 OCT 2021
60 90.15
SF SF
SF
SF SF O SF
#
X
SF
84.76
C
SF
89.61
SF O
BUILDING #3
78
92.90
85.62
SF
71
88.55
SF
79 77
89.00
07 MAR 2022 02 MAY 2022
O
#
WL
90.93
SW 148TH TER
BUILDING #5
X
WL
WL
88.52
06 DEC 2021
SF
#
#
X
69 70
C
SF O
L
REVISIONS:
68
72
D
W
X
92.53
91.63
SW 147TH TER
D
BUILDING #2
61 62
O
BUILDING #7
92.74
WL
88.22
89.03
89.99
86.05
O
#
SCALE:
SF
89.53
89.77
75 91.49
76
O
O
O
O
O
O
O
O
O
O
O
O
O
9.7'
O
# 87.61
91.74 92.62
O
86.67
80 82
86
85
9.8'
S89°13'44"W 1001.67'
74
O
4' WIRE FENCE
5.8'
3' BARBED WIRE FENCE
90.16
3' BARBED WIRE FENCE 84
O
B
7.1'
X
88.16
NORTH
SF O
0.6'E 92.32
2.6'
SF
SF
91.96
O
4' WF
90.44
83
87
88
4' WIRE FENCE
90
89
90.68
90.68
SPECIALTY TREE BARRICADE - SEE SHEET LS-1, DETAIL 2
90.26
89.99
4' WF
81
90.34
95
93
6' WF SF
#
CRUSHED RECYCLED CONCRETE PATH - SEE DETAIL 5/LS-6.
94 92
X
89.13
73
91
0
86.68
20'
40'
80'
86.52
TR
SCALE: 1" = 40'
B
4' BARBED WIRE FENCE 87.01 90.34
90.67
SHEET TITLE:
TREE PRESERVATION AND REMOVAL PLAN
LEGEND
EXISTING TREES AND
75
VEGETATION TO REMAIN A
A SHEET NUMBER: 24 LA
1
EXISTING TREE TO BE REMOVED
LS-2 2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
EXISTING REGULATED TREES AND REQUIRED MITIGATION
7
8
9
10
MANLEY DESIGN
EXISTING TREE INVENTORY
Landscape Architecture
Site Planning
Per Alachua County ULDC, Chapter 410, Article III. Defined Terms J
J
Regulated trees are 8" DBH and over or those trees required as part of a previous development order. Heritage tree size is 20" DBH and over for native tree species and 30" for nonnative trees, Laurel Oaks, and Water Oaks.
Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412
Mitigation per Alachua County ULDC, Article II., Sec. 406.13.b. Mitigation by replacement: Regulated trees eight inches and less than 20 inches DBH, except those trees listed below, shall be replaced at a ratio of one tree planted for every tree removed.
Certificate of Authorization No. LC26000575
Regulated trees greater than or equal to 20 inches DBH, other than trees listed below, shall be replaced with native trees with a cumulative diameter of stems greater than or equal to the diameter of the tree being replaced at the rates found in Table 406.13.1 I
PROJECT NAME:
I
No mitigation is required for abundant species such as Loblolly Pine, Slash Pine, and Sweetgum under 20 inches DBH, and Laurel Oaks and Water Oaks under 30 inches DBH, regardless of condition. Mitigation for trees greater than the 20 and 30 inch size thresholds stated above shall be at a ratio of one tree planted for each tree removed.
LAUREATE VILLAGE TND Phase 2, Unit 2
For those trees retained in excess of the minimum canopy retention requirements with impacts to the dripline described in 406.12(a)(5), replacement trees shall be required at half the rate in 406.13(b)(2), (3) and (4). Replacement trees shall be at least ten feet in height, two caliper inches and shall consist of native vegetation, indigenous to the area, and be Florida Grade No. 1 or better in quality according to the current, most recent edition of "Grades and Standards". Mitigation is based on information as provided within the project survey and direction provided by the Alachua County Forester/Landscape Inspector at the on-site review. Refer to Preliminary Tree Report and plan sheet Tree Charts for tree ratings provided by Forester/Inspector and associated tree mitigation requirements as discussed during the on site review.
H
H
Alachua County, FL
for
HKP Development G
G
SEAL:
F
F
E
E
PROJECT NO:
21-048
CLIENT'S NO.:
NOTE: THE PREVIOUSLY APPROVED PRELIMINARY DEVELOPMENT PLAN IDENTIFIED AND APPROVED PROPOSED BLOCKS AND STREETS WITHIN AREAS WITHIN THE DRIPLINE OF AND OTHERWISE IMPACING EXISTING LIVE OAKS 60" DBH AND LARGER. THEREFORE THE 60” DBH OR GREATER PROVISION OF ULDC 406.12 (SEE BELOW) DOES NOT APPLY TO THIS PROJECT. HOWEVER, CURRENT ALACHUA COUNTY TREE MITIGATION REQUIREMENTS DO APPLY FOR REMOVAL OF THESE AND OTHER TREES. THE ABOVE MITIGATION CALCULATIONS ARE PER CURRENT CODE REQUIREMENTS. “A TREE REMOVAL PERMIT AUTHORIZING THE REMOVAL OF HIGH QUALITY SPECIMEN TREES 60 INCHES DBH OR GREATER MAY ONLY BE ISSUED UPON DEMONSTRATION BY THE APPLICANT THAT THE DEVELOPMENT ACTIVITY CANNOT OCCUR IN ANY LOCATION ON THE SITE, OR THAT REMOVAL IS UNAVOIDABLE DUE TO SITE CONDITIONS AND DESIGN CONSIDERATIONS THAT MINIMIZE IMPACTS TO OTHER REGULATED RESOURCES.”
D
ISSUED FOR:
DEVELOPMENT PLAN REVIEW
ISSUED DATE:
04 OCT 2021
D
REVISIONS:
06 DEC 2021 07 MAR 2022 02 MAY 2022
C
C
PRESERVATION OF EXISTING TREE CANOPY Per Alachua County ULDC, Article II., Sec. 406.12A minimum of 5% of the tree canopy shown on the property's most recent aerial shall be retained. SCALE:
See Civil Sheet 'Tree Canopy Preservation Plan, TREE CANOPY TABLE' for calculations to support below:
B
NOT APPLICABLE
PHASE
EXISTING (AC)
REQUIRED (AC)
RETAINED (AC)
RETAINED % OF TOTAL
Phase 1, Unit 1 & 2
19.87-AC *
0.00-AC *
4.51-AC *
22.70%
Phase 1, Unit 3
23.14-AC *
0.00-AC *
3.27-AC *
14.13%
Phase 2, Unit 1 & 2
2.60-AC *
0.00-AC *
1.92-AC *
73.85%
Future
20.81-AC *
3.33-AC *
TBD
TBD
SHEET TITLE:
TOTALS
66.52-AC *
3.33-AC *
9.70-AC
14.58%
TREE PRESERVATION AND REMOVAL CHART
B
NOTE: THE EXISTING TOTAL WAS ESTABLISHED BY THE APPROVED PRELIMINARY DEVELOPMENT PLAN (PDP).
A
A SHEET NUMBER:
LS-3 1
2
3
4
5
6
7
8
9
10
1
2
4
3
5
7
6
8
9
10
MANLEY DESIGN
86.41
88.40
86.82
D
UP
2 - ML
3 - LIM
3 - PP
TREES SET BACK DUE TO OVERHEAD UTILITY 89.73
H
3 - QM 3 - LIM
TB
36
85.99
OW
85.92
#
TB
PROPOSED SIGN - SEE ARCHITECTURAL 87.17 PLANS
PROPOSED MAINTENANCE PATH - SEE CIVIL PLANS
TB
#
88.34
2 - AR 1 - QVS
UP
D OW
83.27
82.15
TOP=82.08 N. INV=76.88 E. INV=76.33 W. INV=76.38 81.40 81.89 81.99 82.02
24" RCP
82.03
82.21
OW
D
80.71 81.17 81.21 81.39 81.47 81.40
82.77
5' CW ASPHALT
DRMP TEST HOLE # EH-3 ELEV=80.77
78.59 78.94 79.07 79.12
D
D
OW
OW
UP
81.97
TOP=78.85 N. INV=69.80 E. INV=69.75
D
5' CW
79.24
SOD DISTURBED AREAS, TYP.
76.15 76.58 76.75 76.82 76.93 76.75
D OW
UP
LAUREATE VILLAGE TND Phase 2, Unit 2
OW
79.35
3 - PO 6 - ML 82.08
I
EP
8" PVC
3 - PP 3 - LIM PROPOSED MAINTENANCE PATH - SEE CIVIL PLANS 47 - IS 3 - PT 22 - MC 27 - IS 5 - QV
SDO
UTILITY ESMT 13 ORB 2508, PG 1284
4' WF
3 - PP
H
2 - TDS 58 - IS
1 - TDS
3 - PT 81 - MC
80.35 80.11
Alachua County, FL 73.66
for
22 - IS 39 - TF
24 - MC 32 - SBA 25 - SBA 70 - MC
SPECIALTY TREE BARRICADE - SEE SHEET LS-1, DETAIL 2
PROJECT NAME: SDO
D
83.23
ARTERIAL STREET BUFFER
85.01
D OW
83.10
79.27
39 - TF 60 - IS
82.33
HKP Development G
SF
1 - QVS
33 81.76 83.18
87.90
SW 1ST PL
SF
W
9 - MC 2 - QVS
L
SEE CIVIL PLANS FOR GRASSING OF STORMWATER SWALES AND FACILITIES, TYP.
1 - QV 4 - QV
4 - ID
13 - TF
144 - TF
82.32
#
TB
9 - MC
126
TB
2 - TDS
128
5 - SP
81.92
TB
83.59
37 - SBA 65 - MC
2 - ARF
127
2 - QVS
E
50 - TF 80.11
22 - SBA 33 - MC
81.13
80.07
79.36
O
2 - QV
28 - MC 83 - TF
SF
SW 147TH TER
2 - AR
83.63
37 - SBA
F
O
27
68 - IS 3 - AR
31 - SBA
3 - QV 3 - UA
2 - QV
WL
TB
6 - MC
40 - SBA 20 - TF
74.79
67 - SBA
86.31
28
26
1 - QVS
81.32
SF
20 - SBA
TB
#
19 - MC 68 - IS
80.48
SF
85.35
SF
2 - ID
SF
3 - TDS
TB
TYPICAL TREE BARRICADE 85.79 SEE SHEET LS-1, DETAIL 1
SEAL:
16 - MC 12 - IS
O
125
79.96
SF
TB
#
32
SF
TB
IRRIGATION VALVE
F
D OW
81.45
O
30
85.10
79.82
2 - QV
4 - ARF
TB
29 31 IRRIGATION CONTROL BOX
D OW
81.62
24" RCP 82.13
80.38
81.99
88.29
PROPOSED LIGHT, TYP.
11 - IS 13 - SBA
G
24" RCP
82.99 83.04
1 - QV
EXISTING TREE TO REMAIN, TYP.
81.99
82.53
1 - QV
122
123
87.77
121
2' CURB & GUTTER (TYP)
82.16
O
3 - TDS 88.13 14 - MC
TB
34
CRUSHED RECYCLED CONCRETE PATHS - SEE DETAIL 5/LS-6.
3 - QM
84.28 84.76 84.85 84.97
24" RCP
124 4' WIRE FENCE
83.28
NEWBERRY ROAD / SR 26
85.30 85.73
85.97
18" RCP
18" RCP
D
86.30
TOP=85.93 N. INV=80.98 E. INV=80.88 W. INV=80.83
85.09
82.17 82.67 82.54
Certificate of Authorization No. LC26000575
79.72
81.65
O
TB
35
85.86
86.90 86.58 87.04 87.20 86.78 T 87.23 87.11 87.29 88.46 87.59 87.04
OWBUFFER, CANOPY OW 88.86 ARTERIAL STREET
4 - PP
1 - ML
24" RCP
D
88 88 .3 7 .41
87.97
D
87.00
D
88.43 88.62 88.69
86.47
83.55 84.04 83.85
EP 79.14
SF
OW
2 - ML
89.83
87.77
8" CONC CURB (TYP) 85.34 85.81 85.65
81.5 82.13 82.25
81.13
ASPHALT
SF
37
D
OW
UP
89.56 2 - PO
89.20
88.03 87.46
W NEWBERRY ROAD (STATE ROAD 26)
DRMP TEST HOLE # VVH-2 ELEV=80.71 8
DRMP TEST HOLE # EH-2 DRMP TEST ELEV=80.73 HOLE # VVH-3 ELEV=80.63
Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412
EP
SF
89.73
EP
EP
SF
OW
24" RCP
D
D
89.55
89.58
0
DRMP TEST HOLE # VVH-1 ELEV=80.50
T
G OW5' CW
G OW
G OW
G OW
SF
5' CW
OW
89.34
D
88.22
88.0
86.68 87.12 86.89
OW5' CW
Site Planning
J
SF
89.31
89.25
UP
D
SDO 89.15
G OW
G
120
114 - IS 63 - SBA
E
80.34 78.03
SF
88.63 89.23
OW
5' CW 2' CURB & GUTTER (TYP)
SW 147TH DR
88.65
89.03 89.41
88.79
88.28 88.22
TOP=88.98 N. INV=83.98 E. INV=82.88 W. INV=82.83
ASPHALT
2' CURB & GUTTER (TYP)
88.82
87.11 86.94 .22 8 87 87.06 87.32 87.3 6 .9 86.87 6 8
85.39
EP
89.30
57
87.72
88.30
88.
85.58
OW
EP
89.18
87.97
88.70
.03
86.07
89.82
89.66
88
86.90 86.94 86.96
86.37
89.43
88.96
86.98
87.47
87.24 87.14
90.31
89.30
88.00
88.03
UP
89.91
11
12
88.39
1 .4 88 99 . 88
I
14
90.70
2' CURB & GUTTER (TYP)
90.33
13
88.77
EP
OW
90.34
90.00
18" RCP
89.78
8 899.00 .0 1
OW
ASPHALT
89.47
OW
G
EP
EP
EP
X
8" PVC
OW
G
DRMP TEST HOLE # EH-1 ELEV=80.75 G
SF
OW
5' CW
X
81.50
OW
5' CW
G
114
SF
X
G
G
3' WF
115
SF
G
GOW
GOW
5' CW 2' CURB & GUTTER (TYP)
X FOBG
X G
X
X
FOB TV
TOP=85.87 S. INV=81.37
TOP=81.91 S. INV=77.51
SF
X
TOP=88.96 S. INV=84.26
113
SF
CONC APRON
3' WF
FIBER OPTIC CABLE MARKER 3' WF
CBW
118
117
116
129
SF
J
6' VF
Landscape Architecture
6' VF
119
SF
3' WF
3' WF
CBW
78.95
25
5 - TC
16 15
3 - LT
79.62
79.04
SF
07 MAR 2022 02 MAY 2022
SF
2 - UA
C
72 - IS 86.93
7 - PM PROPOSED HYDRANT, TYP. 4 - PM
60 - MC 81.53
MATCHLINE SHEET LS-4 84.90
2 - QV 2 - LT
SF SF SF
82.08
#
85.33
15 - PM
04 OCT 2021 06 DEC 2021
2 - UA
85.61
37 - TF
45 - TF 38 - MC 8 - IS
2 - QV
36 - IS
86.98
MATCHLINE SHEET LS-5
26 - SBA SEE CIVIL
80.63
17
15 - PM
1 - LT
3 - QVS 108 - SBA
O
BUILDING #9
18
11 - PM
ISSUED DATE: REVISIONS:
80.13
C
A/C UNITS- SEE ARCHITECTURAL PLANS, TYP.
1 - LT
SF
19
#
20
82.86
DEVELOPMENT PLAN REVIEW
D
81.20
SW 148TH DR
21
9 - ID 8 - DTV
ISSUED FOR:
O
PROPOSED SCREEN WALL AND TRELLISSEE ARCHITECTURAL PLANS, TYP.
8 - ID 8 - DTV 2 - QV
82.58
BUILDING #11
5 - TC
83.70
PARKING 'D'
22
2 - QV
82.13
O
1 - TD
SF
1 - SP
81.27
#
2 - UA
23
CLIENT'S NO.:
SF
2 - TD
5 - LT
21-048
PROJECT NO:
88 - TF
80.87
81.07
30 - SBA
81.45
SCALE:
SF
5 - TD
2 - TD
SF
SW 2ND LN
40 - MC 32 - TF
O
PROPOSED TRANSFORMER, TYP.
24
D
29 - SBA
DESIGN OF THIS PARCEL BY OTHERS
PROPOSED 6' VINYL FENCE, SEE CIVIL PLANS
SF
17 - TF 3 - AR 27 - MC 4 - PT
#
81.91
20 - TF
NORTH 0
LEGEND B
24 LA
EXISTING TREES AND VEGETATION TO REMAIN
LANDSCAPE PLAN PROPOSED TREE
A
TRANSFORMER CLEAR ZONE AND
SHEET NUMBER:
ACCESS DOOR LOCATION
LS-4 2
3
4
5
6
7
8
80'
SHEET TITLE:
A
1
40'
SCALE: 1" = 40'
B TRANSFORMERS: HEDGE PLANTINGS HAVE BEEN ADDED AROUND TRANSFORMERS AND MECHANICAL EQUIPMENT AS POSSIBLE TO SCREEN FROM ADJACENT ROADWAYS AND USE AREAS. PLANTINGS MUST ADHERE TO CLAY ELECTRIC'S STANDARD OFFSETS AROUND TRANSFORMERS, WHICH REQUIRES A CLEARANCE OF 4' AROUND ALL SIDES AND A 10' OR FULL CLEARANCE ON THE ACCESS DOOR/FRONT FACE. THESE PLANS ASSUMES TRANSFORMERS FACE ADJACENT ROADWAYS OR PAVED AREAS FROM WHICH MAINTENANCE TRUCKS WILL ACCESS. AS SUCH, IT HAS NOT BEEN POSSIBLE TO SURROUND TRANSFORMERS WITH PLANTINGS NOR TO SCREEN FROM ALL VIEWS FROM ADJACENT ROADWAYS AND PARKING. CONTRACTOR TO FIELD ADJUST PLANTINGS PER ACTUAL TRANSFORMER ACCESS DOOR LOCATIONS DURING CONSTRUCTION AS NEEDED TO PROVIDE REQUIRED CLEARANCES, IF ACCESS DOORS AND/OR TRANSFORMER LOCATIONS ARE INSTALLED DIFFERENTLY THAN PLANS INDICATE.
20'
9
10
87.92
49
12 - PM
85.00
6 - QM
4 - TD
TYPICAL TREE BARRICADE - SEE SHEET LS-1, DETAIL 1
1 - QV 2 - UA
50
39
12 - ID
84.47
TB
SF
84.53
83.79
86.76
SW
2 - QV
2 - QSL
85.15
6 - TC 1 - SP
14 - DTV
87.36
2 - UA
87.40
#
5 - ID
X X
5 - TC
91.22
2 - LT 10 - ID
4 - LP
1 - LT
1 - UA
1 - LT
15 - PM
87.28
89.00
1 - SP88.55
14 - PM 14 - PM
15 - PM
1 - QM
89.99
3 - QM 3 - QV
83.61
07 MAR 2022 02 MAY 2022
84.76
C
86.05 89.13
91.96
SF
SCALE:
75
90.16
92.32
84
91.49 88.16
76
85
PROPOSED 6' VINYL FENCE, SEE CIVIL PLANS
O
O
O
O
O
O
O
O 4' WF
92.62
91.74
O
74
80 82
86
83
87
88
89.99
90.34
90
89
90.68
90.68
SPECIALTY TREE BARRICADE - SEE SHEET LS-1, DETAIL 2
90.26
4' WF
81
94 92
X
#
85.62
89.77
CRUSHED RECYCLED CONCRETE PATH - SEE DETAIL 5/LS-6.
04 OCT 2021 06 DEC 2021
SF
6 - LT
3 - QV 4 - QM
1 - LT 7 - UA
89.61
SOD DISTURBED AREAS, TYP.
ISSUED DATE: REVISIONS:
73
B
O 1 - QSL
14 - PM
PROPOSED 6' VINYL FENCE, SEE CIVIL PLANS
SF O SF
5 - ID
88.52
78
1 - LT 92.90
DEVELOPMENT PLAN REVIEW
SF
5 - TC
ISSUED FOR:
D
5 - ID
SF O
1 - QV
5 - TC
SF O
X
79 77
CLIENT'S NO.:
14 - ID
4 - LP
21-048
PROJECT NO:
SF
15 - PM
SW 147TH TER
15 - PM
SF
15 - PM
BUILDING #2
#
9 - ID 5 - TC
71
87.61
17 - DTV 1 - QV
4 - DTV
3 - LT
WL #
2 - QV
92.53
4 - QM
90.93
3 - LT 15 - PM 15 - PM
BUILDING #3
X
68
2 - LT 1 - LT
SW 148TH TER
91.63
7 - IVS
BUILDING #5
1 - LT
90.15
7 - IVS
PARKING 'C'
61 62
88.22
89.03
PARKING 'A'
1 - LT
PARKING 'B'
SF
12 - PM 1 - QV
BUILDING #7
92.74
2 - QV
2 - QV
1 - LT
2 - QV
2 - QV
WL
60
7 - IVS 2 - QV
SF
88.27
2 - QV
89.53
84.28 85.24
88.76
64
69 70
E
SF
86.78
7 - IVS 2 - QM
86.67
SF
13 - PM 1 - QSL
65
63
SF
O
5 - TC
SF
87.69
3 - SP
12 - PM
3 - PM
1 - LT
88.26
88.06 88.37
14 - PM
F 85.95
SF
X #
A/C UNITS- SEE ARCHITECTURAL PLANS, TYP.
BUILDING #4
HYDRANT- SEE CIVIL PLANS, TYP.
BUILDING #6
# 66
2 - QV
SF
BUILDING #1
6 - LT 86.15
5 - LP 7 - IVS 1 - QV 2 - LT
PROPOSED SCREEN WALL AND TRELLISSEE ARCHITECTURAL PLANS, TYP. 91.86
67
14 - PM
1 - QV
PARKING 'E'
5 - SP
O
2 - SP 86.55
4 - QML 5 - TC
82.71
SF 1 - SP
3 - QM
1 - SP
C
SEAL:
7 - ID 1 - UA
F
72
7 - PM
19 - DTV
5 - QSL 2 - SP
SF
88.39
2 - UA
SF
PROPOSED LIGHT, TYP.
87.05
2 - ARF 1 - QV
1 - QV
G
O
59
SW 3RD PL
HKP Development
1 - QV
58
D
3 - ID 5 - TC
88.36
2 - QV 1 - UA
for
2 - LIM 92 - PM 1 - LIM
87.69
8 - ID
91.05
SF
6 - QV
SF
SOD DISTURBED AREAS, TYP.
Alachua County, FL
SOD
83.93
88.21
E
3 - QV
2 - UA
88.02
87.79
D 3R
PL
83.61
88.60
H
84.47
SF
86.45
87.15
82.85
9 - ID
PROPOSED 6' VINYL FENCE, SEE CIVIL PLANS
SF SF
SPECIALTY TREE BARRICADE - SEE SHEET86.54 LS-1, DETAIL 2 EXISTING TREE TO REMAIN, TYP.
102
SF
83.09
SF
103
84.48
100 101
98 97
84.81
57
99
O
7 - IVS
5 - ID 6 - TC
56
85.84
87.17
1 - QVS 3 - LT 5 - LP 7 - IVS
SOD DISTURBED AREAS, TYP.
85.66 86.28
96
55
2 - LT
85.79
84.45
2 - UA
2 - UA
86.27
86.06
SF
52
83.92 85.73
SW 148TH DR
90.94
SF
88.51
BUILDING #10
PARKING 'D'
BUILDING #8
14 - PM
#
51
2 - QV
PROPOSED MAINTENANCE PATH - SEE CIVIL PLANS 2 - QSL 1 - QV
86.17
#
#
16 - PM
O
86.26
87.60
LAUREATE VILLAGE TND Phase 2, Unit 2
3 - QVS
6 - QM
O
H
106
WL
14 - PM
3 - QV
85.67
90.55
45
TB
2 - UA
TB
4 - LT
87.19
I
84.31
104 107
87.70
15 - PM
89.44
105 E IBL SS LE CE AC NIC TAB PIC
14 - PM
PROPOSED TRANSFORMER,TYP.
TB
2 - UA
BLE SSI LE CE AC NIC TAB PIC
89.25
PROJECT NAME:
SF
LE
TB
TAB
LE TAB
WL
4' WIRE FENCE
G
SF
NIC PIC
NIC PIC
108
3 - QM
53 54
Certificate of Authorization No. LC26000575
84.85
41 42 43 44
I
Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412
O
87.94
40
83.33
TB
1 - QVS
38
TB
TB
13 - ID
Site Planning
J
82.06
16 - ID
SF
PROPOSED PICNIC PAVILION - SEE ARCHITECTURAL PLANS.
Landscape Architecture
84.32
47
36 - IS 20 - TF SEE CIVIL 26 - MC PLANS FOR 23 - SBA 75 - TF GRASSING OF 1 - QVS 18 - SBA STORMWATER 53 - IS SWALES AND 4 - TDS 95 - IS FACILITIES, 75 - TF TYP. 138 - MC 83 - TF 109 - IS
84.56
MANLEY DESIGN
81.20
48 46
26 - SBA
O
1 - LT 2 - UA
38 - MC 8 - IS
10
82.93
4' WIRE FENCE
9
85.02
J
86.98
2 - UA
85.61
8
MATCHLINE SHEET LS-4 MATCHLINE SHEET LS-5
2 - QV 2 - LT
7
6
SF
5
SF
4
3
SF
BUILDING #9
2
#
1
95
93
6' WF 86.68
91 86.52
TR 87.01 90.67
90.44
0
NORTH
90.34
40'
80'
SCALE: 1" = 40'
B
LEGEND
20'
SHEET TITLE: 24 LA
EXISTING TREES AND
LANDSCAPE PLAN
VEGETATION TO REMAIN TRANSFORMERS: HEDGE PLANTINGS HAVE BEEN ADDED AROUND TRANSFORMERS AND MECHANICAL EQUIPMENT AS POSSIBLE TO SCREEN FROM ADJACENT ROADWAYS AND USE AREAS. PLANTINGS MUST ADHERE TO CLAY ELECTRIC'S STANDARD OFFSETS AROUND TRANSFORMERS, WHICH REQUIRES A CLEARANCE OF 4' AROUND ALL SIDES AND A 10' OR FULL CLEARANCE ON THE ACCESS DOOR/FRONT FACE. THESE PLANS ASSUMES TRANSFORMERS FACE ADJACENT ROADWAYS OR PAVED AREAS FROM WHICH MAINTENANCE TRUCKS WILL ACCESS. AS SUCH, IT HAS NOT BEEN POSSIBLE TO SURROUND TRANSFORMERS WITH PLANTINGS NOR TO SCREEN FROM ALL VIEWS FROM ADJACENT ROADWAYS AND PARKING. CONTRACTOR TO FIELD ADJUST PLANTINGS PER ACTUAL TRANSFORMER ACCESS DOOR LOCATIONS DURING CONSTRUCTION AS NEEDED TO PROVIDE REQUIRED CLEARANCES, IF ACCESS DOORS AND/OR TRANSFORMER LOCATIONS ARE INSTALLED DIFFERENTLY THAN PLANS INDICATE.
A
PROPOSED TREE A SHEET NUMBER:
TRANSFORMER CLEAR ZONE AND ACCESS DOOR LOCATION
1
2
3
4
5
6
7
8
9
10
LS-5
1
2
4
3
5
7
6
8
9
10
MANLEY DESIGN Landscape Architecture
J
J
LANDSCAPE NOTES
PLANT SCHEDULE TREES AR
QTY 10
BOTANICAL NAME Acer rubrum
COMMON NAME Red Maple
SIZE 7 gal., 7` ht. x 24" sprd., 3/4" cal.
SPACING As shown
ARF
8
Acer rubrum `Florida Flame`
Florida Flame Red Maple
30 gal., 11` ht. x 48" sprd., 2" cal.
As shown
NOTES
1.
PRE-CONSTRUCTION MEETING: COORDINATE AND CONDUCT AN ON-SITE MEETING WITH THE ALACHUA COUNTY FORESTER/LANDSCAPE INSPECTOR OR DESIGNATED COUNTY REPRESENTATIVE TO DISCUSS EXISTING REGULATED TREES AND PROTECTION METHODS. CONTACT: (352) 374-5243 EXT. 3503.
2.
EXISTING UTILITIES: LOCATE ALL UTILITIES PRIOR TO COMMENCEMENT OF WORK. CALL SUNSHINE STATE ONE CALL - SEE LOGO BELOW.
3.
INVASIVE SPECIES: REMOVE INVASIVE, NONNATIVE PLANT SPECIES AS LISTED ON THE FLORIDA PROHIBITED AQUATIC PLANTS LIST OR THE FLORIDA NOXIOUS WEED LIST FROM THE SITE PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. ALL HERBICIDE APPLICATIONS TO CONTROL INVASIVE, NONNATIVE PLANTS IN WETLAND OR UPLAND SET-ASIDE AREAS, INCLUDING BUFFERS, SHALL BE APPLIED BY A CONTRACTOR LICENSED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES, DIVISION OF AGRICULTURAL ENVIRONMENTAL SERVICES, WITH A CURRENT CERTIFICATION IN NATURAL AREAS WEED MANAGEMENT.
LIM
12
Lagerstroemia indica x faurei `Muskogee`
Muskogee Crape Myrtle
30 gal., 10` ht. x 48" sprd., 2" cal.
As shown
Multi-trunk, five canes minimum
LT
55
Liriodendron tulipifera
Tulip Tree
30 gal., 11` ht. x 48" sprd., 2" cal.
As shown
ML
11
Magnolia grandiflora 'Little Gem'
Little Gem Dwarf Southern Magnolia
30 gal., 11` ht. x 48" sprd., 2" cal.
As shown
PP
13
Pinus palustris
Longleaf Pine
30 gal., 10` ht. x 42" sprd., 2" cal.
As shown
PT
10
Pinus taeda
Loblolly Pine
7 gal., 6` ht. x 24" sprd., 3/4" cal.
As shown
PO
5
Platanus occidentalis
American Sycamore
30 gal., 11` ht. x 48" sprd., 2" cal.
As shown
QML
4
Quercus michauxii
Swamp Chestnut Oak
30 gal., 11` ht. x 48" sprd., 2" cal.
As shown
QM
38
Quercus michauxii
Swamp Chestnut Oak
7 gal., 6` ht. x 24" sprd., 3/4" cal.
As shown
QSL
11
Quercus shumardii
Shumard Oak
30 gal., 11` ht. x 48" sprd., 2" cal.
As shown
QV
76
Quercus virginiana
Southern Live Oak
30 gal., 11` ht. x 48" sprd., 2" cal.
As shown
QVS
16
Quercus virginiana
Southern Live Oak
7 gal., 7` ht. x 24" sprd., 3/4" cal.
As shown
TD
14
Taxodium distichum
Bald Cypress
30 gal., 10` ht. x 48" sprd., 2" cal.
As shown
8.
PLANT MATERIAL, GENERAL: ALL PLANT MATERIALS SHALL MEET 'FLORIDA NUMBER 1' REQUIREMENTS AS PER THE MOST CURRENT EDITION OF 'FLORIDA GRADES AND STANDARDS FOR NURSERY PLANTS', FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES.
TDS
15
Taxodium distichum
Bald Cypress
7 gal., 5` ht. x 20" sprd., 3/4" cal.
As shown
9.
UA
37
Ulmus alata
Winged Elm
30 gal., 11` ht. x 48" sprd., 2" cal.
As shown
PALMS SP
QTY 22
BOTANICAL NAME Sabal palmetto
COMMON NAME Cabbage Palmetto
SIZE 16` C.T., 12" min. cal. at 4.5` above grade
SPACING As shown
NOTES Regenerated, minimum four fronds
PROPOSED TREES: TREES PROPOSED ALONG STREETS, WITHIN PAVING, OR IN PARKING LOT ISLANDS SHALL BE A MINIMUM OF TEN FEET TALL, HAVE A MINIMUM TRUNK CALIPER OF TWO INCHES, AND BE IN 30-GALLON MINIMUM CONTAINER. TREES PROPOSED IN STORMWATER FACILITIES OR ELSEWHERE SHALL BE A MINIMUM OF FOUR FEET TALL, HAVE A MINIMUM TRUNK CALIPER OF 3/4 INCHES, AND BE IN 7-GALLON MINIMUM CONTAINERS. NEW TREES LOCATED OUTSIDE OF LARGER PLANTING AREAS/WITHIN TURF AREAS TO HAVE 6" OF PLASTIC DRAIN TUBING INSTALLED AROUND THE BASE OF THEIR TRUNK TO PROTECT FROM MOWER AND STRING TRIMMER IMPACTS.
SHRUBS DTV
QTY 70
BOTANICAL NAME Dianella tasmanica `Variegata`
COMMON NAME Variegated Flax Lily
SIZE 3 gal., 24" ht. x 18" sprd.
SPACING 24" o.c.
NOTES Full
ID
144
Ilex cornuta `Dwarf Burford`
Dwarf Burford Holly
3 gal., 24" ht. x 18" sprd.
30" o.c.
IVS
49
Ilex vomitoria 'Schillings Dwarf'
Schillings Dwarf Yaupon Holly
3 gal., 24" ht. x 18" sprd.
30" o.c.
LP
18
Loropetalum chinense rubrum `Plum Delight`
Plum Delight Loropetalum
3 gal., 24" ht. x 18" sprd.
30" o.c.
PM
451
Podocarpus macrophyllus
Podocarpus
3 gal., 24" ht. x 9" sprd.
30" o.c.
VINES TC
QTY 57
BOTANICAL NAME Trachelospermum jasminoides `Confederate`
COMMON NAME Confederate Jasmine
SIZE 3 gal., 24" ht. x 12" sprd.
SPACING 30" o.c.
NOTES Remove staking and train to trellis
SHRUB AREAS IS
QTY 860
BOTANICAL NAME Ilex vomitoria 'Schillings Dwarf'
COMMON NAME Schillings Dwarf Yaupon Holly
CONT 3 gal., 24" ht. x 18" sprd., 36" o.c.
FIELD2
FIELD3
MC
725
Muhlenbergia capillaris
Pink Muhly Grass
3 gal., 24" ht. x 18" sprd., 42" o.c.
SBA
621
Spartina bakeri
Sand Cordgrass
3 gal., 24" ht. x 18" sprd., 42" o.c.
TF
860
Tripsacum dactyloides
Fakahatchee Grass
3 gal., 24" ht. x 18" sprd., 42" o.c.
SOD/SEED SOD
QTY 8,688,447
BOTANICAL NAME Paspalum notatum `Argentine`
COMMON NAME Argentine Bahia Grass
SIZE sod
I
H
NOTE: 1. ENSURE PLANTING PIT DRAINS WELL PRIOR TO INSTALLATION. 2. REMOVE TREE FROM CONTAINER OR REMOVE UPPER 1/3 OF BURLAP AND WIRE MESH FOR B&B TREES. 3. SLICE ROOTBALL VERTICALLY ON OUTSIDE EDGES OF AND AROUND ROOTBALL. 4. TREE TO BE PLUMB. STAKE TREE IF NEEDED. SUBMIT TREE STAKING DETAILS AND LAYOUT FOR APPROVAL.
G
6" PLASTIC DRAIN TUBING IF TREE LOCATED OUTSIDE OF LARGER PLANTING AREA/IN TURF TOP OF ROOTBALL 1-2" ABOVE FINISH GRADE MULCH, 3" THICKNESS TYPICAL AND ONLY 1" OVER ROOTBALL 3" - 6" SOIL BERM TO OUTSIDE OF ROOTBALL F
4.
ON-SITE LITTER REMOVAL: REMOVE ALL EXISTING LITTER AND DEBRIS VISIBLE ON THE PROJECT SITE.
5.
PLANTING PREPARATION: REMOVE ALL CONSTRUCTION DEBRIS, LIMEROCK, GRAVEL, ROAD BEDDING, LITTER, AND OTHER ITEMS POTENTIALLY DAMAGING TO PLANT GROWTH WITHIN PROPOSED LANDSCAPE AND TURF AREAS PRIOR TO PLANTING. MAINTAIN EXISTING GRADES UNLESS OTHERWISE APPROVED BY THE OWNER'S REPRESENTATIVE. IF FILL IS REQUIRED, USE A CLEAN, SANDY LOAM WITH pH 5.5-6.5 AND EXCAVATED FROM LOCAL SOURCES AND DEEP PITS SUCH THAT IT IS FREE OF WEEDS, SEEDS, LITTER, TOXINS, AND OTHER ITEMS HARMFUL TO PLANTINGS.
6.
PRUNING: IF TREE OR ROOT PRUNING IS REQUIRED, THESE ACTIVITIES SHALL BE PERFORMED BY AN ARBORIST CERTIFIED BY THE INTERNATIONAL SOCIETY OF ARBORICULTURE (ISA). TREE PRUNING SHALL BE DONE IN ACCORDANCE WITH THE MOST CURRENT VERSION OF THE AMERICAN NATIONAL STANDARD FOR TREE CARE OPERATIONS "TREE. SHRUB AND OTHER WOODY PLANT MAINTENANCE" (ANSI 300) AND "PRUNING. TRIMMING. REPAIRING. MAINTAINING, AND REMOVING TREES. AND CUTTING BRUSH—SAFETY REQUIREMENTS" (ANSI Z133). NO MORE THAN 25 PERCENT OF THE CROWN SHOULD BE REMOVED AT ONE TIME. ON YOUNG TREES, LIMB REMOVAL SHALL LEAVE NO MORE THAN 33 PERCENT OF THE TRUNK BARE OF BRANCHES.
7.
MINIMUM PLANTING AREA: A MINIMUM PERVIOUS AREA OF 200 SF AND MINIMUM PLANTING AREA OF 140 SF SHALL BE PROVIDED FOR CANOPY TREES WITHIN PARKING AREAS. A MINIMUM PLANTING AREA OF 200 SF SHALL BE PROVIDED FOR CANOPY TREES OUTSIDE OF PARKING AREAS. A MINIMUM PERVIOUS AREA OF 120 SF AND MINIMUM PLANTING AREA OF 90 SF SHALL BE PROVIDED FOR UNDERSTORY TREES WITHIN PARKING AREAS. A MINIMUM PLANTING AREA OF 120 SF SHALL BE PROVIDED FOR UNDERSTORY TREES OUTSIDE OF PARKING AREAS. PLANTING AREAS SHOULD BE FREE FROM COMPACTED MATERIAL TO A DEPTH OF 18-INCHES, MINIMUM.
10.
NEW TREE STAKING: IF NECESSARY TO MAINTAIN TREES PLUMB, TREES SHALL BE STAKED WITH BIODEGRADABLE STAKING MATERIALS.
11.
PROPOSED SHRUBS: PROPOSED SHRUBS SHALL BE A MINIMUM OF TWO FEET TALL AND BE IN 3-GALLON MINIMUM CONTAINERS.
12.
SOD: ALL UNPAVED AND DISTURBED AREAS OUTSIDE OF PROPOSED TREE, SHRUB, AND GROUNDCOVER PLANTINGS SHALL BE SODDED. SEE CIVIL PLANS FOR SODDING INFORMATION FOR STORMWATER FACILITIES. SOD SHALL BE SAND-GROWN, STRONGLY ROOTED, WITHOUT SYNTHETIC STABILIZING MATERIALS, FREE OF PESTS, AND CERTIFIED FREE OF NOXIOUS WEEDS BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES, DIVISION OF PLANT INDUSTRY.
LOOSEN SIDE SLOPES OF PLANTING PIT
EQUAL
TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. ROOTBALL SITS ON BOTTOM OF PLANTING PIT
MULCHING: THREE INCHES OF MULCH, SETTLED, SHOULD COVER TREE RING PLANTING AREAS AND ALL SHRUB AND GROUNDCOVER PLANTING AREAS. MULCH SHOULD BE NO DEEPER THAN ONE INCH OVER THE TOP OF TREE ROOTBALLS. USE PINESTRAW MULCH IN ALL AREAS. MULCH TO BE FREE OF DEBRIS, STICKS, AND CONES. NO PLASTIC OR NON-BIODEGRADABLE WEED CLOTH OR SURFACE COVERS TO BE USED.
14.
IRRIGATION: A TEMPORARY AUTOMATIC IRRIGATION SYSTEM IS REQUIRED FOR ALL NEW REQUIRED LANDSCAPING INSTALLED [407.46(A)]. SEE CIVIL PLANS FOR IRRIGATION METER/POINT OF CONNECTION TO POTABLE WATER. TEMPORARY IRRIGATION SYSTEMS MUST BE REMOVED ONCE THE PLANTS ARE ESTABLISHED OR WITHIN TWO YEARS, WHICHEVER OCCURS FIRST. PRIOR TO THE INSTALLATION OF A NEW PERMANENT IRRIGATION SYSTEM OR SUBSTANTIAL MODIFICATION TO AN EXISTING SYSTEM, AN IRRIGATION PLAN MUST BE SUBMITTED TO AND APPROVED BY THE ALACHUA COUNTY ENVIRONMENTAL PROTECTION DEPARTMENT THROUGH THE ONLINE ALACHUA COUNTY IRRIGATION PROFESSIONAL PORTAL. THE IRRIGATION SYSTEM SHALL COMPLY WITH THE LANDSCAPE IRRIGATION DESIGN AND MAINTENANCE STANDARDS FOUND IN ARTICLE II OF PART II, TITLE 7, CHAPTER 79 OF THE ALACHUA COUNTY CODE, WHICH, AMONG ADDITIONAL DESIGN STANDARDS, REQUIRES THE FOLLOWING. FOR MORE INFORMATION, CONTACT THE ALACHUA COUNTY ENVIRONMENTAL PROTECTION DEPARTMENT AT 352-264-6800.
EQUAL
2 X ROOTBALL WIDTH
· · · SPACING
15.
NOTES Sand grown and weed free
PLANTING DETAIL 1 TREE SCALE: N.T.S
16.
Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412 Certificate of Authorization No. LC26000575
PROJECT NAME:
I
LAUREATE VILLAGE TND Phase 2, Unit 2 H
Alachua County, FL
for
HKP Development G
13.
FINISH GRADE
CL
E
Site Planning
SEAL:
F
LIMIT HIGH VOLUME IRRIGATION TO 60% OF THE LANDSCAPED AREA. ALL NEWLY PLANTED TREES SHALL HAVE INDIVIDUAL LOW FLOW OR MICRO-IRRIGATION SUPPLIES. ALL IRRIGATION SYSTEMS ARE RQUIRED TO HAVE A MOISTUR SENSOR/AUTOMATIC RAINFALL SHUTOFF DEVICE.
RESPONSIBILITY: ALL LANDSCAPING FROM THE APPROVED LANDSCAPE PLAN IS REQUIRED TO BE REPLACED IF AND/OR WHEN IT FAILS. OWNER IS RESPONSIBLE FOR THE SURVIVAL OF PLANTINGS. ALL TREE STAKING, IF INSTALLED, SHALL BE REMOVED WITHIN ONE YEAR FOLLOWING RECEIPT OF CERTIFICATE OF OCCUPANCY. IF A TREE THAT IS REQUIRED FOR MITIGATION OR TO FULFILL THE REQUIREMENTS OF THE LAND DEVELOPMENT CODE DIES OR IS SEVERELY DAMAGED, AS DETERMINED BY THE COUNTY'S REPRESENTATIVE, THEN THE TREE MUST BE REPLACED BY THE OWNER PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY.
E
LETTER OF COMPLIANCE: PROVIDE ONE WEEK NOTICE TO LANDSCAPE ARCHITECT REGARDING SCHEDULING THE FINAL REVIEW OF INSTALLED LANDSCAPE AND EXISTING VEGETATION PROTECTION FOR THE PURPOSES OF PREPARING THE LETTER OF COMPLIANCE.
MULCH, 3" THICKNESS TYPICAL. 1" MAXIMUM OVER ROOTBALL. SOIL BERM TO OUTSIDE OF ROOTBALL.
FINISH GRADE
PROJECT NO:
21-048
CLIENT'S NO.:
D
ISSUED FOR:
DEVELOPMENT PLAN REVIEW
ISSUED DATE:
04 OCT 2021
D
(5) LAYERS OF BURLAP
NOTE: SUBMIT SHOP DRAWINGS FOR STAKING LAYOUT AND DETAILS.
2 x 4 x 12, TYP. BATTEN (2) 1" NYLON STRAPS CUT BRACE TO BE FLUSH WITH BATTEN AND ATTACH WITH SCREWS
SCARIFY SIDE SLOPES
REVISIONS:
TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. 3 X ROOTBALL DIMENSION
06 DEC 2021 07 MAR 2022 02 MAY 2022
ROOTBALL ON EXISTING SOIL
AND GROUNDCOVER PLANTING DETAIL 3 SHRUB SCALE: N.T.S
C
NOTE: 1. FLAG TRAIL LOCATION IN FIELD FOR OWNER'S REPRESENTATIVE'S APPROVAL PRIOR TO INSTALLATION. 2. LAYOUT SUCH THAT NO DIRECTIONAL SLOPE IS GREATER THAN 5% AND NO CROSS SLOPE IS GREATER THAN 2%. 3. INSTALL SURFACING TO PROVIDE POSITIVE DRAINAGE OFF OF TRAIL SURFACE.
(3) 2 x 4 BRACES, VERTICAL, AND EVENLY SPACED AROUND TRUNK
ER NT CE G ON PACIN S
SAFETY FLAG AT MIDPOINT TOP OF ROOTBALL 1-2" ABOVE FINISH GRADE
8'
12" OFFSET FOR GROUNDCOVERS 18" OFFSET FOR SHRUBS
MULCH, 4" THICKNESS TYPICAL AND ONLY 1" OVER ROOTBALL 3" - 6" SOIL BERM TO OUTSIDE OF ROOTBALL FINISH GRADE
30" MIN. DEPTH
CL
EQUAL
BRACE NAILED TO 2 x 4 WOOD STAKE WITH TOP BELOW GRADE
2 X ROOTBALL WIDTH
ON CENTER SPACING
CRUSHED RECYCLED CONCRETE FINES, NO LARGER THAN 38" AND 50% PASSING NO. 4 SEIVE AND NO MORE THAN 15% PASSING NO. 200 SIEVE COMPACTED AND FLUSH WITH ADJACENT GRADE ADJACENT EXISTING GRADE
NOT APPLICABLE
B
SHEET TITLE:
OUTSIDE ROW FOLLOWS CURVE AS SHOWN. ROWS REMAIN PARALLEL AROUND CURVE.
LOOSEN SIDE SLOPES OF PLANTING PIT TAMP BACKFILL IN 6" LIFTS. MIX IMPORTED FILL, IF NEEDED, WITH NATIVE SOIL. ROOTBALL SITS ON BOTTOM OF PLANTING PIT
EQUAL
SCALE:
4"
1/3 TRUNK HEIGHT, MINIMUM
CLEAR TRUNK HEIGHT
C
B
CUT INTO GRADE AT EDGE OF BED SUCH THAT MULCH SURFACE MEETS FINISH GRADE.
WOVEN SYNTHETIC GEOTEXTILE FABRIC. TURN UP AT EDGES.
BEDLINE OR PAVING EDGE TRIANGULAR LAYOUT, TYPICAL, IN STRAIGHT RUNS AND AS MUCH AS POSSIBLE AROUND CURVES. ON CENTER SPACING DISTANCE SHALL BE AS INDICATED IN SCHEDULE.
A
PLANTING DETAIL 2 PALM SCALE: N.T.S.
4
NATIVE SUBGRADE A
SHRUB AND GROUNDCOVER LAYOUT DETAIL
5
SCALE: N.T.S
CRUSHED RECYCLED CONCRETE PATH DETAIL
LANDSCAPE SCHEDULE, NOTES, AND PLANTING DETAILS SHEET NUMBER:
SCALE: N.T.S
LS-6 1
2
3
4
5
6
7
8
9
10
1
2
4
3
5
7
6
8
9
10
MANLEY DESIGN Landscape Architecture
FINAL DEVELOPMENT PLAN CHECKLIST
PAVED GROUND SURFACE SHADING -PARKING LOT B
PROPOSED TREE CANOPY COVERAGE J
XIII. LANDSCAPE PLAN NOTES, DETAIL, AND CALCULATIONS
I N/A
Tree Planting Detail Tree Protection Detail Legend General Notes, Material, Grassed Areas, Irrigation, Details Tree Canopy Data, including: At least 5% of the existing tree canopy retained (ULDC 406.12(a)3.) At least 50% of parking areas under canopy at 20 yrs. (ULDC 407.43(d)3.h.) At least 30% of the site will be under canopy within 20 years parking areas under canopy at 20 yrs. (ULDC 406.12(a)3.) Tabular list of all regulated trees indicating the species of tree, the diameter at breast height, and if the tree will either remain or will be relocated, removed, or mitigated (ULDC 406.12(c)2.e.) Proposed mitigation table (tag number, species & caliper, required mitigation) Development Plan sheet reference map, if more than one development plan sheet
TREE NAME - SCIENTIFIC COMMON (SYM.)
XIV. DETAILED LANDSCAPE PLAN, MAXIMUM SCALE 1" = 50'
H N/A
Per Alachua County ULDC, Article IV., Sec. 407.43.1.c. Screening shall be provided where a paved ground surface area lies within 50 feet of and is visible from any street right-of-way. At least 50% of the paved ground surface area shall be under mature canopy within 20 years. Provided: Screening is not required since paved ground service is not visible from street right of way. See below for canopy.
Per Alachua County ULDC, Article II., Sec. 406.12 At least 30% of the site shall be under mature canopy within 20 years - % met as per below.
Existing tree size and type Location and field tag number for each regulated tree to remain undisturbed during construction (ULDC 406.12c.2.d.) Location of trees to be removed Proposed trees and shrubs location, type, and number Stormwater facilities comply with ULDC & MTPO design and landscape requirements Buffers & screening meet landscape requirements of pd, activity center, master plan and ULDC (ULDC 407.43) Silt fence and tree barrier location (ULDC 406.12.d.) Show proposed final grades & contours Show lighting and utilities to identify potential conflicts Landscape to be provided for driveway connections, offsite roadway improvements, and utility extensions
EST. 20-YR. CROWN
Acer rubrum 'Florida Flame' Florida Flame Red Maple (AR)
25
Lagerstroemia indica x faurei 'Muskogee' Muskogree Crape Myrtle (LIM)
15
Liriodendron tulipifera Tulip Tree (LT)
25
CROWN AREA PROPOSED (SF) QUANTITY 491
18
PROPOSED % OF CANOPY ON SITE
PROPOSED CANOPY AREA ON SITE (SF)
TREE NAME - SCIENTIFIC COMMON (SYM.)
8,838
100%
Liriodendron tulipifera Tulip Tree (LT)
Magnolia grandiflora 'Little Gem' Little Gem Dwarf Southern Magnolia (MG)
10
Pinus plaustris Longleaf Pine (PP)
25
177
12
491
79
491
Any substantial applicant-initiated revisions shall require payment of additional fees. The director shall determine if a proposed revision is to be deemed substantial, and the determination can include such factors as: 5.) reduction or relocation of proposed buffers landscaping or conservation areas
REQUIRED MITIGATION
25
491
10
100%
4,910
Platanus occidentalis Sycamore (PO)
40
1257
5
100%
6,285
Quercus michauxii Swamp Chestnut Oak (QM)
25
Quercus shumardii Shumard Oak (QS)
30
Quercus virginiana Live Oak (QV)
45
42
Mitigation required per Alachua County ULDC, Article II., Sec. 406.13.b. See Chart on Sheet LS-3.
100%
11
1591
Taxodium distichum Bald Cypress (TD)
20
Ulmus alata Winged Elm (UA)
40
Sabal palmetto Cabbage Palm (SP)
15
315
F
Mitigation surplus/defecit
Surplus: 201.5 inches (100 trees)
Mitigation required
Requirement satisfied
1257
177
15
15 Trees
Area (SF)
25% Area
10604
2651
Manley Design, LLC 224 NW 2nd Avenue, Suite E Gainesville, Florida 32601 (352) 363-7412
Quercus virginiana Live Oak (QV)
45
1591
4
4,773.0
75%
25% Area in Landscape
2, 832 SF PROJECT NAME:
1591
4
I
3,182.0
50%
EAST BASIN
Total Shading SF Provided
9305.3
Total SF Paved Ground Surface
18,650 50
1 Canopy Tree / 35 LF Perimeter
25% Area in Landscape
Perimeter (LF)
Trees Required
PROVIDED
1550
44
45 trees
Area (SF)
25% Area
120060
30015
LAUREATE VILLAGE TND Phase 2, Unit 2
30,133 SF
H
EST. 20-YR. CROWN
CROWN AREA PROPOSED (SF) QUANTITY
PROPOSED % OF CANOPY ON SITE
Alacha County, FL
PROPOSED CANOPY AREA ON SITE (SF)
Ilex opaca American Holly (IO)
25
491
2
Liriodendron tulipifera Tulip Tree (LT)
25
Quercus virginiana Live Oak (QV)
45
1591
1
75%
1,193.3
Quercus virginiana Live Oak (QV)
45
1591
4
50%
3,182.0
for
245.5
25%
HKP Development 491
5
613.8
25%
G
9,135
100%
22
527
146,372
100%
37
PROVIDED
7,777
100%
29
Trees Required
Per Alachua County ULDC, Article IV., Sec. 407.43.1.c. Screening shall be provided where a paved ground surface area lies within 50 feet of and is visible from any street right-of-way. At least 50% of the paved ground surface area shall be under mature canopy within 20 years. Provided: Screening is not required since paved ground service is not visible from street right of way. See below for canopy.
20,622
100%
92
Perimeter (LF)
PAVED GROUND SURFACE SHADING -PARKING LOT C
REQUIRED MITIGATION
468 inches (234, 2" trees)
45
TREE NAME - SCIENTIFIC COMMON (SYM.) 707
1 Canopy Tree / 35 LF Perimeter
REQUIREMENT
G
Total inches of proposed trees as shown in plan
Quercus virginiana Live Oak (QV)
6,383
100%
Pinus taeda Loblolly Pine (PP)
491
REQUIREMENT
Certificate of Authorization No. LC26000575
Per Alachua County ULDC, Article II., Sec. 402.07.a.
266.5 inches
1,350.3
25%
% Shaded Paved Ground Surface
DEVELOPMENT REVIEW FEES
Mitigation required as per 'Tree Preservation & Removal Plan' calculations
11
PROPOSED CANOPY AREA ON SITE (SF)
869
100%
13
491
PROPOSED % OF CANOPY ON SITE
27,005
100%
11
25
CROWN AREA PROPOSED (SF) QUANTITY
J
WEST BASIN
2,124
100%
55
EST. 20-YR. CROWN
LANDSCAPING OF STORMWATER MANAGEMENT FACILITIES Per Alachua County ULDC, Article IV., Sec. 407.43.2.
Site Planning
46,509
100%
SEAL:
3,894 Total Shading SF Provided
5234.5 10,044
Total Proposed 20-Year Canopy (SF)
290723
Total SF Paved Ground Surface
Total Existing Canopy Retained (SF)
83635
% Shaded Paved Ground Surface
Total Canopy (SF)
374358
F
52
PAVED GROUND SURFACE SHADING -PARKING LOT D Site Area (SF) - excluding CHW commercial parcel
PRESERVATION OF EXISTING TREE CANOPY
% Site Under Canopy at 20-Years
Per Alachua County ULDC, Article II., Sec. 406.12A minimum of 5% of the tree canopy shown on the property's most recent aerial shall be retained. E
EXISTING (AC)
REQUIRED (AC)
RETAINED (AC)
Per Alachua County ULDC, Article IV., Sec. 407.43.1.c. Screening shall be provided where a paved ground surface area lies within 50 feet of and is visible from any street right-of-way. At least 50% of the paved ground surface area shall be under mature canopy within 20 years. Provided: Screening is not required since paved ground service is not visible from street right of way. See below for canopy.
32
TREE NAME - SCIENTIFIC COMMON (SYM.)
STREET TREES Per Alachua County ULDC, Article IV., Sec. 407.43.1.b. Provide along both sides of streets and roads or in medians and within a minimum 8 ft. wide planting strip. Plant in the center 30% of the planting strip. Street trees in commercial or mixed use districts may be planted in islands or bulb-outs where on-street parking is present. Parking islands or bulb-outs shall have a minimum pervious area of 90 SF and be free of compacted soil to a depth of 18". Street trees shall be spaced so that the distance between two adjacent trunks is no less than one half the sum of their 20-year canopy crowns and no more than the sum of their 20-year canopy crowns. Street trees shall be planted between the street and the sidewalk whenever space permits to protect pedestrians and calm traffic. Eligible trees as per Table 407.50.1.
See Civil Sheet 'Tree Canopy Preservation Plan, TREE CANOPY TABLE' for calculations to support below:
PHASE
1,162,418
RETAINED % OF TOTAL
Phase 1, Unit 1 & 2
19.87-AC *
0.00-AC *
4.51-AC *
22.70%
Phase 1, Unit 3
23.14-AC *
0.00-AC *
3.27-AC *
14.13% Provided: See plan for street trees planted along project drives. Above requirement is met.
Phase 2, Unit 1 & 2
2.60-AC *
0.00-AC *
1.92-AC *
73.85%
Future
20.81-AC *
3.33-AC *
TBD
TBD
TOTALS
66.52-AC *
3.33-AC *
9.70-AC
14.58%
ROADWAY LANDSCAPE BUFFERS Per Alachua County ULDC, Article IV., Sec. 407.43.d.
D
Location / Type Requirement North / 'ARTERIAL/COLLECTOR' 10 ft. average & 5 ft. minimum width Per 100/LF: 2 - Canopy trees 2 - Understory trees
TREE SPECIES DIVERSITY Per Alachua County ULDC, Article IV., Sec. 407.11.a. New tree plantings shall not include more than 50 percent of any one genus or 25 percent of any one species. Total Proposed Trees C
Length (LF)
Per 100 LF
Required
Provided
Total Proposed Species (Quercus virginiana) %
1001
10.01
20
25
491
1
50%
245.5
Liriodendron tulipifera Tulip Tree (LT)
25
491
16
25%
1,964.0
Quercus virginiana Live Oak (QV)
45
1591
4
75%
4,773.0
Quercus virginiana Live Oak (QV)
45
Ulmus alata Winged Elm (UA)
40
E
PROJECT NO:
1591
1257
4
2
ISSUED FOR:
DEVELOPMENT PLAN REVIEW
ISSUED DATE:
04 OCT 2021
D
1885.5
75%
21-048
CLIENT'S NO.:
3,182.0
50%
Total Shading SF Provided
12050.0
Total SF Paved Ground Surface
22,314
% Shaded Paved Ground Surface
06 DEC 2021 07 MAR 2022 02 MAY 2022
54
C
92 = 25%
Per Alachua County ULDC, Article IV., Sec. 407.43.1.c. Screening shall be provided where a paved ground surface area lies within 50 feet of and is visible from any street right-of-way. At least 50% of the paved ground surface area shall be under mature canopy within 20 years. Provided: Screening is not required since paved ground service is not visible from street right of way. See below for canopy.
Per Alachua County ULDC, Article IV., Sec. 407.43.1.a. Areas dedicated to pedestrian circulation that are not coincident with a street shall have canopy trees spaced not more than an average of 40 feet on center. B
EST. 20-YR. CROWN
CROWN AREA PROPOSED (SF) QUANTITY
PROPOSED % OF CANOPY ON SITE
PAVED GROUND SURFACE SHADING -PARKING LOT E Per Alachua County ULDC, Article IV., Sec. 407.43.1.c. Screening shall be provided where a paved ground surface area lies within 50 feet of and is visible from any street right-of-way. At least 50% of the paved ground surface area shall be under mature canopy within 20 years. Provided: Screening is not required since paved ground service is not visible from street right of way. See below for canopy.
PROPOSED CANOPY AREA ON SITE (SF)
Liriodendron tulipifera Tulip Tree (LT)
25
491
2
25%
245.5
Quercus virginiana Live Oak (QV)
45
1591
2
75%
2,386.5
Quercus virginiana Live Oak (QV)
45
TREE NAME - SCIENTIFIC COMMON (SYM.)
#1 pedestrian walkway along north/west boundaries 687
17
5 existing to remain; 12 proposed
#2 pedestrian walkway along west/south boundaries 1623
41
17 existing to remain; 54 existing to remain just west of property line; 29 proposed
1591
4
50%
3,182.0
Total Shading SF Provided
5814.0
Total SF Paved Ground Surface
11,526
% Shaded Paved Ground Surface
EST. 20-YR. CROWN
CROWN AREA PROPOSED (SF) QUANTITY
438
11
PROPOSED % OF CANOPY ON SITE
45
1591
1
75%
1,193.3
Quercus virginiana Live Oak (QV)
45
1591
1
50%
795.5
Quercus virginiana Live Oak (QV)
45
1591
2
25%
795.5
Ulmus alata Winged Elm (UA)
40
1257
3
50%
1,885.5
50
Total Shading SF Provided
4669.8
Total SF Paved Ground Surface
8,357
% Shaded Paved Ground Surface
12 proposed
SCALE:
PROPOSED CANOPY AREA ON SITE (SF)
Quercus virginiana Live Oak (QV)
#3 pedestrian walkway in central park Total LF = 438 LF/40
PROPOSED CANOPY AREA ON SITE (SF)
Liriodendron tulipifera Tulip Tree (LT)
19 Canopy trees proposed, 1 to remain 20 Understory Trees
PAVED GROUND SURFACE SHADING -PARKING LOT A
PEDESTRIAN WALKWAYS LANDSCAPING
A
PROPOSED % OF CANOPY ON SITE
REVISIONS:
145 = 40%
TREE NAME - SCIENTIFIC COMMON (SYM.)
Total LF = 1623 LF/40
CROWN AREA PROPOSED (SF) QUANTITY
357
Total Proposed Genus (Quercus) %
Total LF = 677 LF/40
EST. 20-YR. CROWN
NOT APPLICABLE
B
SHEET TITLE:
LANDSCAPE CALCULATIONS A
56
SHEET NUMBER:
LS-7 1
2
3
4
5
6
7
8
9
10