CENTRALIZED SUPERVISION SYSTEMS
Send an e-mail to documentation@linergy.it and you will receive a link to download the constantly updated technical-sales material. NOTE Specify in object: “Documentation”
1212
CENTRALIZED SUPERVISION SYSTEMS
WHAT ARE THEY? They are systems which control all the luminaires of an emergency system through a computerized station. The station can manage and store the information which is coming from the luminaires and ensure perfect and timely system maintenance. In addition to complete programmability of all the system’s variables, new generation stations like those produced by LINERGY, allow for more advanced management of information and interaction with other intelligent management systems, with which they integrate perfectly.
SYSTEM EXPANDABILITY - SPY CENTER Up to 2560 products that are controllable via MDL addressing modules, along with the possibility to connect up to 128 650W lines, which are equipped with shortcircuit protection. A high power range that runs from 500W to more than 80KW, along with panels and accessories that are resistant to the spreading of flames in the event of a fire. Combined operation for the maintained mode indication of escape routes and emergency luminaires in nonmaintained mode in a single final circuit.
WHY USE THEM? For the safety of the building, regulations have established that the emergency system must always be kept in perfect working order. In particular, all the luminaires must be operational and the internal battery must be able to ensure nominal duration. Regular maintenance of the emergency system is essential in order to guarantee its correct operation.
EASE OF INSTALLATION - SPY SYSTEM The system must univocally identify every luminaire in the system; it is therefore important to know how the latter operates. The majority of systems on the market foresee the assignment of a binary address to each individual luminaire, by setting a dip-switch onto the same. The system is equipped with an automatic installation procedure, through which it automatically recognizes the luminaires connected via a univocal code. In other words, the installer only has to take note of the code in order to locate the luminaire.
WHERE TO USE THEM? As a rule, these systems are used for the maintenance of plants which have a considerable number of luminaires. However, the availability of advanced systems at very reasonable prices makes them worthwhile even in plants with less than 50 luminaires. The use of these systems makes everything easier and more professional. HOW TO CHOOSE THEM SPY SYSTEM OR SPY CENTER? SPY CENTER meets all needs whenever the project requires a single battery group for all of the plant’s emergency fixtures. It is an intelligent control system for centralized plants which also utilize standard ceiling lights or ceiling lights that are already assembled. If the project requires a dynamic station that monitors the status of the autonomous emergency fixtures, SPY SYSTEM is the right choice. NUMBER OF LUMINAIRES THAT ARE CONNECTABLE TO THE STATION It is important to know how many luminaires a station can manage in accordance with the system that is to be created. Nevertheless, when choosing a station it is advisable to leave room for future expansion. SYSTEM EXPANDABILITY - SPY SYSTEM Regarding systems that might one day expand, it is necessary to evaluate the possibility of expanding the station chosen and the simplicity with which this expansion can be achieved. SPY SYSTEM stations can manage up to 1280 luminaires by simply introducing repeater modules for the data bus every 128 luminaires. In the case of systems which have more than 1280 light points, several stations can communicate with each other. In this way, expansion is practically unlimited.
EASE OF INSTALLATION - SPY CENTER The final circuits can be connected directly into the system’s cabinet, as its size can be determined according to the project’s requirements. A 19” rack for easy slide-in assembly and disassembly, an independent monitoring and control system and coordinated by RS485 bus. Complete distributions available in E30 (the line is resistant to fire for 30 minutes). PRESENTATION OF THE DATA The clearness with which the data is presented is very important. The most advanced systems, like Linergy systems, are equipped with an LCD screen where it is easy to read the result of the tests and other data. Almost all the systems come with a thermal printer for data presentation. POSSIBILITY OF REMOTE MANAGEMENT Remote connection to a PC to check the data and plan any maintenance interventions without having to be on site is possible. POSSIBILITY OF INTEGRATION In any building, the emergency system management system must be “open” to communication with any other systems present inside the structure. SPY SYSTEM AND SPY CENTER are equipped with an Ethernet port with TCP/IP protocol. This is standard within local networks for perfect integration with the intranet or internet networks.
13
1414
CENTRALIZED SUPERVISION SYSTEMS
Spy System
TM
SPY SYSTEM is the cutting-edge system for the complete control, supervision and maintenance of an emergency system with self-contained luminaires.
NEW AND MORE INTUITIVE GRAPHICS VIRTUAL KEYPAD ON TOUCH SCREEN LCD POSSIBILITY TO UPDATE STATION SOFTWARE POSSIBILITY TO MODIFY THE APPLIANCE’S SERIAL NUMBERS POSSIBILITY TO SWITCH ON/OFF MAINTAINED APPLIANCES* POSSIBILITY TO CHANGE THE LIGHT INTENSITY*
A
*Only on appliances set-up
C
IP20
D
B
A=255 mm B=375 mm C=75 mm D=85 mm
14
Power supply Absorption User interface Printer Duration in the absence of network Max. number of luminaires managed Connectable luminaires Connectable repeaters Luminaire data bus External interfaces Ethernet protocol
230V 50 Hz 20 VA 7” colour graphic display with touch screen Thermal 16 column 4 h (with all data saved) 1280 with single station 256 on the station + 128 for every repeater module Max 8 2 polarized cables (twisted and shielded) 3 USB Ports TCP/IP with web server
documentation@linergy.it | direct assistance (+39) 0735 597425
1414
CENTRALIZED SUPERVISION SYSTEMS
Spy System Centralized supervision system of the emergency system 7” colour display with graphic user interface and touch screen Built-in alphanumeric thermal printer Li-FePO4 battery Non-volatile historic memory of the events and tests carried out on the system Data exchange with luminaires on two-wire data buses with safety protocol A maximum of 1280 luminaires are manageable with a single station 2 and 4-way repeater modules
Management of 32 logical groups of luminaires Automatic luminaire acquisition Possibility of remote connection via modem Internet port with TCP/IP protocol for intranet/internet connection Built-in web server for system management via internet MODBUS System wireless interface KONNEX Power supply: 230 Vac 50-60 Hz
Complete programmability of the station’s operating modes
Maximum battery operating temperature EN 605982-22
Complete programmability of the times and days the tests are to be carried out
Models are available with 19’’ rack container and for DIN guide
Test management allows to choose the test day and time for each of the 32 groups into which the system is divided. It was conceived to be easily integrated with modern building automation systems. In fact, it has an Ethernet port with TCP/IP protocol: the standard for all modern technological systems. The station is also equipped with a Web Server for access to all of its functions via internet, using a common browser. PERIODIC SYSTEM TESTS Spy System controls the efficiency of the emergency system in compliance with EN 50172 and UNI 11222. It signals and records any anomalies that the system displays by running two types of periodic tests on the connected emergency luminaires: 1. Functional test The general operation of the lamp is tested, especially the light source. A negative result indicates that the light source has to be replaced. 2. Duration test A shortage of electrical energy is simulated. The luminaire is lit via the internal battery until it is completely discharged. In this way, it is possible to measure the real autonomy of the emergency luminaire and compare it with nominal. The failure of this test indicates that the battery should be replaced.
The station is set-up to carry out the functional test every 15 days and the duration test every 90 days. These frequencies can be varied to ones liking by operating on both the entire system and groups of luminaires. Even the parameters for the running of the test can be changed. For example, the 2-hour duration test can be arranged for a 3-hour duration luminaire if such duration is required for the specific application. In this way, it is possible to have a system that lasts longer over time. EVENT LOG The station manages a complete event log on non-volatile memory. In addition to the test results, all the events that occur on the system, such as emergency interventions or any inhibitions, are memorized. The event log can be viewed on the display and printed on the built-in printer. By connecting to an on-site PC or remotely via the intranet/internet network, the event log can be accessed and copied onto the PC for subsequent elaborations. WEB SERVER To connect with the SPY SYSTEM station, whether it is PC linked to the station via local network or internet, no specific program is necessary. In fact, the station is equipped with a web server that allows access to all the functionalities. With the use of a common browser for Internet (for example, Firefox or Internet Explorer), it works with all operating systems, Windows, Mac or Linux. Maximum flexibility and minimum cost.
15
1616
CENTRALIZED SUPERVISION SYSTEMS
Spy System COMPARISON AMONG THE VARIOUS SPY SYSTEM MODELS Version
Order code
Short code
Display Printer
Max Luminaires
Installation
Protection rating
Dimensions A
C
SSCENT-00
SS 1101
YES
NO
1280
Wall
SSCENT-PR
SS 1102
YES
YES
1280
Wall
A=255 mm B=375 mm C=75 mm D=85 mm
D
IP20 B
C
SSPRO-00
SS 1201
YES
NO
1280
SSPRO-PR
SS 1203
YES
YES
1280
19” Rack (4 Units) 19” Rack (4 Units)
E
D
IP20
A
F
B
7”
G
D
SSPRO-II
SS 1202
NO
NO
1280
19” Rack (1 Unit)
IP20 E
A B C
A=482 mm B=132 mm C=440 mm D=151,5 mm E=155,5 mm F=160 mm G=124 mm
A=465 mm B=44 mm C=482,6 mm D=440 mm E=140 mm F=150 mm
F
A
SSMINIPLUS
SS 1301
YES
optional 98
DIN rail
SSMINIPLUS-00
SS 1302
YES
optional 128
DIN rail
SSMINIPLUS-170
SS 1303
YES
optional 170
DIN rail
A=213 mm B=110 mm C=53,5 mm
C
IP20 B
”
4,3
A
SSMINI
SS 1401
NO
optional 98
DIN rail
SSMINI-00
SS 1402
NO
optional 128
DIN rail
SSMINI-170
SS 1403
NO
optional 170
DIN rail
C
IP20
D
B
A=215 mm B=108 mm C=62 mm D=90 mm
A
SSMICRO
SS 1501
NO
NO
30
DIN rail
A=71 mm B=70,5 mm C mm C=91
IP20 B
Can be managed with Android and iOS devices via an app that can be downloaded from
C A
SSW-REP2 SSW-REP4
A 268 A 269
B
NO
NO
512
Guida DIN
IP20
A=101 mm B=119 mm C=35,5 mm
Wireless bridge for Spy System units, see page 20
ACCESSORIES SS PRINTER Printer module for SS MINI, SS MINI-00, SS MINI-170, SS MINIPLUS, SS MINIPLUS-00, SS MINIPLUS-170. SS REP Repeater Available in 2 and 4-way versions, it allows for the expansion of the ceiling lights connected to the station. Possibility of installation onto a DIN rail. SPY VIEW Graphic supervision software This software allows the accurate view of the position of every single fixture, thus highlighting its status. Supplied on USB stick.
16
ORDER CODE
SHORT CODE
DESCRIPTION
SS-KNX-CENT
A116
HW AND SW INTERFACE KONNEX SSCENT
1
SS-KNX-MINI
A117
HW AND SW INTERFACE KONNEX SSMINI
1 1
PACK
SS-MODBUS
A118
SW INTERFACE FOR TCP/MODBUS
SSPRINTER
A121
PRINTER MODULE FOR SPY MINI
1
SS-REP-2
A122
BUS REPEATER 2X128 256 LUMINAIRES
1
SS-REP-4
A123
BUS REPEATER 4X128 512 LUMINAIRES
1
SSW-REP2
A268
BUS REPEATER 1X128 WIRELESS + 1X128 BUS
1
SSW-REP4
A269
BUS REPEATER 1X128 WIRELESS + 3X128 BUS
1
SSW-EXTENDER
A270
SPY SYSTEM WIRELESS RANGE EXTENDER
1
SS-SERVIZIO
A119
START-UP FUNCTION FOR SINGLE SPY SYSTEM
1
SS-VIEW
A120
GRAPHIC SUPERVISION SOFTWARE SPYSYSTEM
1
SWITCHBOX
A124
COMAND FOR LIGHT LEVEL
1
1616
CENTRALIZED SUPERVISION SYSTEMS
Spy System
128 luminaires
BUS
KONNEX INTERFACE
MOUSE
KEYPAD
128 luminaires
BUS
BUS
lan
RJ-45
USB
tcp/modbus internet
USB
REMOTE PC
router wi-fi
Ceiling lights max 128, max cable length 500 m
Bus 2 Bus 1
L N
T SS-REP/4
Terminate the Bus BUS MASTER
Ceiling lights max 128, max cable length 500 m
IN
Shop luminaires
L N
OUT
T Terminate the Bus Ceiling lights max 128, max cable length 500 m Ceiling lights max 128, max cable length 500 m Bus 4 Bus 3 Bus 2 Bus 1
Bathroom luminaires
T Terminate the Bus
Ceiling lights max 128, max cable length 500 m
Supermarket luminaires
SS-REP/4 BUS MASTER
IN
OUT
Bus 1 Bus 2
Ethernet connection
230 V~ 50 Hz
L N
Bus KNX
17
1818
CENTRALIZED SUPERVISION SYSTEMS
Spy Micro
TM
SPY MICRO is the most economical system for the management of the main supervision and maintenance functions of a small emergency system.
APP AVAILABLE FOR IOS AND ANDROID BOTH ON SMARTPHONE AND TABLET CAN BE INSTALLED IN THE ELECTRIC CONTROL BOARDS ON STANDARD DIN GUIDE AUTOMATIC DEVICE SWITCH-OFF ON COMPLETION OF MAINTENANCE
Wi-Fi connection Over 5 hours duration 30 luminaires controlled
POSSIBILITY TO SWITCH ON/OFF MAINTAINED LUMINAIRES* SENDING OF SYSTEM REPORT VIA SMS OR E-MAIL *Only on Led luminaires set-up
IP20 A
B
C
A=71 mm B=70,5 mm C=91 mm
18
Power supply Absorption User interface Printer Duration in the absence of network Max. number of luminaires managed Battery Luminaire data bus External interfaces
230 Vac 50 Hz 2 VA App on smartphone/tablet Android/iOS No 5h 30 with single station Li-FePO4 2 polarized wires (twisted and screened cable) Wi-Fi
documentation@linergy.it | direct assistance (+39) 0735 597425
1818
CENTRALIZED SUPERVISION SYSTEMS
Spy Micro Centralized supervision system of the emergency system
MANUAL TESTS ON THE SYSTEM Spy System controls the efficiency of the emergency system in compliance with EN 50172 and UNI 11222. It uses the APP to signal any anomalies that occur on the system.
Li-FePO4 battery for 5 hours duration in the absence of a network Automatic luminaire acquisition
LOG BOOK The station uses the APP to manage a complete events log. In addition to the test results, the application shows all the main events that occur on the system, such as emergency interventions or any inhibitions, are memorized.
Historic memory of all events and tests run on the resident system on smartphone A maximum of 30 luminaires are manageable with a single device
APP SPY MOBILE
Wi-Fi IEEE 802.11b/g interface Power supply: 230 Vac 50-60 Hz
for iPhone iPad Android smartphone Android tablet
Maximum battery operating temperature EN 60598-2-22
SPY MICRO
Ceiling lights max 30, max cable length 500 m
APP SPY MOBILE
L N
BUS
SPY MICRO WIRELESS The Wireless interface can also be used with Spy Micro by means of the Wireless Repeater. Wireless control of luminaires
Control by means of Spy Mobile app
No installation times and costs
Up to 30 luminaires can be controlled
Mixed or totally wireless connection
High-performance certified frequency
SSW-REP2
FLOOR 00 PIANO
FLOOR 1 1 PIANO
BUS
SSW-REP4
230 ReteVac 230 V
230 ReteVac 230 V
19
2020
CENTRALIZED SUPERVISION SYSTEMS
Spy System Wireless
TM
Spy System Wireless is an advanced radio supervision system for emergency installations with self-contained luminaires. Unlike the traditional Spy System, communication is made without wires through the creation of a network with mesh technology. Spy System Wireless represents the wireless evolution of Linergy’s Spy System centralized control. The frequency used by the radio device and the type of structure created by the mesh network make it easy to overcome normal environmental obstacles. This allows the positioning of the devices at points which would be out of reach with bus cable. Wireless technology is adaptable to all Spy System units, including Spy Micro. The system is based on the same operating principle as normal control units, to which must be added a Wireless Repeater connected to the control unit via RS485 bus cable.
C A B
A=101 mm B=119 mm C=35.5mm
20
STANDARDS Complies with RED Directive 2014/53/EU Complies with European standards: EN 300 220-2, EN 301 489-1, EN 301 489-3, EN 60950-1 Operating frequency: 868 MHz
documentation@linergy.it | direct assistance (+39) 0735 597425
2020
CENTRALIZED SUPERVISION SYSTEMS
Spy System Wireless CONTROL UNIT ADVANTAGES From the Wireless Repeater it is possible to choose between a wireless-only system or a mixed connection. This means that emergency luminaires connected via bus cable to the Spy System can coexist with emergency “wireless” luminaires. In the case of extension of pre-existing Spy Systems, it will suffice to replace only the traditional repeater already present in most cases (or at most add it), with the Spy System Wireless version (SSW-REP2 or SSW-REP4) MAXIMUM NUMBER OF WIRELESS PRODUCTS 1280 for SPY SYSTEM 98,128,170 for SPY MINI 30 for SPY MICRO LUMINAIRES ADVANTAGES The emergency appliances equipped with wireless communication module will only require a 230 Vac power supply. The compatible ordering codes are all those with Spy System Wireless function. In case of installation in critical radio coverage environments, correct radio communication can in any case be tested by means of MONITOR BUS function and then gradually continue with installation, exploiting the great advantage of being able to push to considerable distances inside enclosed environments. Maximum indoor coverage (corridors, rooms with obstructions, etc.): ~ 20 meters (distance between two luminaires) Maximum coverage in open spaces (sheds, open space offices etc.): ~ 100 meters (distance between two luminaires)
SYSTEM CONFIGURATION: Configuration is done during the test phase: the installer does not have to configure anything, but simply supply the luminiares. Self-acquisition of products takes place automatically as in the case of traditional units In case of having to move luminaire X in place of luminaire Y (e.g. Cristal Evo in place of Lyra Evo) the network will auto-reconfigure itself automatically and the operation will be absolutely transparent for the installer. Same features as a Spy System: identification of luminaires via serial/number already installed in the factory, possibility of assigning descriptions, creating groups, etc.
SECOND FLOOR
SSW-EXTENDER This is an accessory which restores mesh communication between Wireless Spy System products in critical environments where radio coverage may be compromised by certain factors such as thick walls or plasterboard structures. The wireless repeater node (SSW-EXTENDER) therefore acts as a repeater between the wireless Repeater and the first luminaire of the system or between luminaires with radio coverage problems. Dimensions: 96x56x30mm, 92x25x56mm (power supply unit)
Max distance between adjacent luminaires 20 m
FIRST FLOOR
MESH NETWORK Spy System Wireless creates a wireless network of the MESH type. In a network of this type, each product operates as a repeater node (for the supervision signal from the central unit) to the other nodes (apparatus).
Each node of the network, i.e. each luminaire, is interconnected with the others. Operating in this way, inside a typical installation environment, it is possible to reach considerable distances from the central unit, exploiting the maximum range of coverage of each single node. The system guarantees an easy and fast initial configuration thanks to the system’s self-learning capability. Management over time is also easier than traditional systems because a Wireless Spy System permits self-generation in the event of failure of one or more luminaires. If the radio signal between two adjacent luminaire fails, the connection is re-established by the closest node between them.
Max distance between adjacent luminaires 20 m
GROUND FLOOR
(optional)
Max distance between adjacent luminaires 20 m
cable
cable
21
2222
CENTRALIZED SUPERVISION SYSTEMS
Dali
New series of emergency luminaires with DALI standard protocol, manufactured in accordance with standard EN 62386 and compatible with all* DALI power stations.
FUNCTIONALITY
With the advent of home automation in modern systems, lighting control plays an important role in ensuring safety, comfort and energy efficiency. Currently there are several standards that allow the automatic adjustment of the system. These include DALI (Digital Addressable Lighting Interface), an international standard protocol compliant with standard EN 62386, which guarantees the interchangeability of ECGs from different manufacturers, simple installation and flexibility programming. DALI is a standard system shared by the entire lighting industry. The protocol, included in the standard of electronic ballasts EN 60929, is defined specifically by standard EN 62386.
BUS, EIB, LON systems
The DALI protocol makes it possible to simultaneously operate the lighting controls, sensors, control units, electronic ballasts and lamps, including emergency lights, using the same interface (Master DALI).
DALI systems
* The DALI Master (or gateway) must support the protocol defined in standard EN 62386-202 – Self-contained emergency lighting (device type 1).
1...10 V systems COST
22
documentation@linergy.it | direct assistance (+39) 0735 597425
2222
CENTRALIZED SUPERVISION SYSTEMS
Dali PRODUCT REGULATORY COMPLIANCE EN 62386-101 EN 62386-102 EN 62386-207 EN 62386-202 EN 60598-1 EN 60598-2-22
The products available, compliant with standard DALI, are listed in the code tables of each series; for example, for DALI Cristal Evo, see page 65.
This greatly simplifies the wiring of the system (bus) and the programming of the whole lighting system.
ADVANTAGES DALI systems are installed using the same material of electrical installations, without shielded or polarised cable. The system is addressable, each component has its own unique ID number, so it can be programmed and configured for a specific function or be reconfigured at will as necessary, by changing the requirements. Switch-on, adjustments, light scenes and functional measurements can all be managed for the individual product, groups or the entire system.
Connecting Linergy emergency luminaires to the DALI will automatically address them. The standard EN 62386-202 allows you to: Check the status of the light source (lamp or LED module) Check the battery Perform or schedule functional and duration tests on the individual device, for groups or the entire system Control the light intensity on luminaires Lighting (L) and Maintained (M) Dimmer the light source according to a logarithmic curve for maximum user comfort
DALI AND EMERGENCY The biggest advantage offered by DALI in the context of an emergency is to have a single field bus to connect the ordinary lighting and emergency lighting.
LEGEND
Parking lights L N
Indicator equipment
Emergency lighting equipment Sensor
Emergency lighting equipment
Supermarket lights L N
Sensor
Ordinary lighting equipment DALI BUS PSU Master
Keypad
Shop lights L N
DALI BUS PSU Master
Sensor Sensor
Office lights
DALI BUS 230V ac Power Line
L N
L N
L N
Keypad
Sensor
LN
23
2424
CENTRALIZED SUPERVISION SYSTEMS
Spy Center
TM
Spy Center’s advanced technology is the result of collaboration with a European company which has been active in the emergency lighting sector for more than 20 years, with over 2,000 systems already installed.
documentation@linergy.it | direct assistance (+39) 0735 597454
24
2424
CENTRALIZED SUPERVISION SYSTEMS
Spy Center
Central supervision and control unit Can manage more than 2,560 products
Monitoring module for the individual emergency fixtures Up to 20 ceiling lights for every line
External module for line monitoring Up to 128 lines protected against short circuits
Integrated circuit board for line control Wide range of power from 500W to more than 80KW
External module for monitoring phases
Battery Log Battery monitoring system
STRONG POINTS No inverter to convert direct current into alternating current Electrical energy and Bus travel on the same wires (DEDICATED) Maximum flexibility in the dimensioning of the necessary power output Dedicated contactor for Emergency lighting Expansive system modularity for system and power type Compliant with EN 50171 – EN 50272-2 – EN 50172 – UNI 11222 regulations Batteries with a 10-year life declaration (as required by regulations) Possibility to customize the cabinets to specific measures Station with matrix display and buttons for the programming Complete programming flexibility for functioning type: M, N/M and AI via configuration Software Remote management via web
25
2626
CENTRALIZED SUPERVISION SYSTEMS
Spy Center In cases of standard functioning the output is powered in By-Pass by the normal electrical network (230Vac)
System block diagram Vac
By-Pass
In emergency situations the output is powered by the direct voltage of the nominal 216Vdc battery group No inverter is present between the batteries and the output
Output
Vdc
AC input
Raddrizzatore + Caricabatteria
EASY SYSTEM CONNECTION Simple, Safe, Strong and Reliable Communication together with power conductors
MIXED-MODE TECHNOLOGY Possibility of installing the following types of luminaires on the same line: Not Maintained N/M, Maintained M and On with Switch AI (Control units only) The system communicates the status of the tests and the system programming with the same wires with which it provides electrical energy Reduction in the costs of materials and installation
ORDER CODE
SHORT CODE
DESCRIPTION
SC100P10B
SC 1101
SPY CENTER Base System, 1000 W, 2 outputs (1 N/M + 1 M), Pb batteries lifetime 10 years, 1h duration
1
SC100P10C
SC 1102
SPY CENTER Control System, 1000 W, 1 CTRL (4 circuits), Pb batteries lifetime 10 years, 1h duration
1
SC100P30B
SC 1103
SPY CENTER Base System, 1000 W, 2 outputs (1 N/M + 1 M), Pb batteries lifetime 10 years, 3h duration
1
SC100P30C
SC 1104
SPY CENTER Control System, 1000 W, 1 CTRL (4 circuits), Pb batteries lifetime 10 years, 3h duration
1
SC200P10B
SC 1105
SPY CENTER Base System, 2000 W, 4 outputs (2 N/M + 2 M), Pb batteries lifetime 10 years, 1h duration
1
SPY CENTER Control System, 2000 W, 1 CTRL (4 circuits), Pb batteries lifetime 10 years, 1h duration
1
SC200P10C
SC 1106 SC 1107
SPY CENTER Base System, 2000 W, 4 outputs (2 N/M + 2 M), Pb batteries lifetime 10 years, 3h duration
1
SC200P30C
SC 1108
SPY CENTER Control System, 2000 W, 1 CTRL (4 circuits), Pb batteries lifetime 10 years, 3h duration
1
SC400P10B
SC 1109
SPY CENTER Base System, 4000 W, 6 outputs (4 N/M + 2 M), Pb batteries lifetime 10 years, 1h duration
1
SC 1110
SPY CENTER Control System, 4000 W, 2 CTRL (8 circuits), Pb batteries lifetime 10 years, 1h duration
1
SC400P30B
SC 1111
SPY CENTER Base System, 4000 W, 6 outputs (4 N/M + 2 M), Pb batteries lifetime 10 years, 3h duration
1
SC400P30C
SC 1112
SPY CENTER Control System, 4000 W, 2 CTRL (8 circuits), Pb batteries lifetime 10 years, 3h duration
1
SC600P10B
SC 1113
SPY CENTER Base System, 6000 W, 8 outputs (6 N/M + 2 M), Pb batteries lifetime 10 years, 1h duration
1
SC600P10C
SC 1114
SPY CENTER Control System, 6000 W, 3 CTRL (12 circuits), Pb batteries lifetime 10 years, 1h duration
1
SC600P30B
SC 1115
SPY CENTER Base System, 6000 W, 8 outputs (6 N/M + 2 M), Pb batteries lifetime 10 years, 3h duration
1
SC 1116
SPY CENTER Control System, 6000 W, 3 CTRL (12 circuits), Pb batteries lifetime 10 years, 3h duration
1
SC200P30B
SC400P10C
SC600P30C
26
PACK
ORDER CODE
SHORT CODE
DESCRIPTION
PACK
SCCTRL
A100
INTEGRATED CIRCUIT BOARD
1
SCFRDB
A101
FIREPROOF BRANCH BOX E30
1 1
SCLAN
A102
INTEGRATED CIRCUIT BOARD LAN CONNECTION
SCMDL-L
A104
MODULE FOR MONITORING INDIVIDUAL EMERGENCY LAMP L
1
SCMF
A105
EXT. MODULE FOR 7-PHASE MONITORING
1
SCML
A106
EXTERNAL MODULE FOR LINE MONITORING
1
SCNDB1
A107
E30 FOR EXTERNAL MODULE 125X125X60
1
SCNDB2
A108
E30 FOR EXTERNAL MODULE 170X145X70
1
SCNDB3
A109
E30 FOR EXTERNAL MODULE 243X168X83
1
SCPRINTER
A110
THERMAL PRINTER FOR SPY CENTER
1
SCSERVIZIO
A111
SYSTEM ACTIVATION SERVICE SPY CENTER
1
SCTRASFERTA
A112
INTERNATIONAL TRAVEL FOR SYSTEM START-UP
1
SCTRASFERTA1
A113
INTERNATIONAL TRAVEL WITH 1 NIGHT FOR SYSTEM START-UP
1 1
SCMF2-S
A097
EXT. MODULE FOR MONITORING OF THE 1 CHANGE OVER CONT.PHASE
SCPSR
A096
SYNOPTIC REMOTE PANEL 166X161X71
1
SCBAT-RX-SC
A258
BATTERY MONITORING SYSTEM SPY CENTER RECEIVER
1
SCBAT-TX
A260
BATTERY MONITORING SYSTEM TRANSMITTER
1
Possibility of having a system with customized configuration
2626
CENTRALIZED SUPERVISION SYSTEMS
Spy Center ENHANCED CAPABILITIES OF THE SPY CENTER SYSTEM Up to 2560 products controllable via MDL-L Up to 128 650W lines protected against short circuits Wide range of power from 500W to more than 80KW Boards and accessories for fire resistance
BATTERY LOG The battery LOG is a system developed for the monitoring of lead sealed batteries present inside SPY CENTER central battery system. The system consists of TRANSMITTER modules connected to each battery and a module mounted on the Spy Center mimic panel. Both the TRANSMITTER module and the RECEIVER module have an LED for signaling the operating status of each single unit.
Possibility to remote control the power lines directly on the floor and/or fire-proof compartment via the SC/ML module (4 lines for 20 products per line) Unique module for the management of programmable products (like N/M or M or IA) directly from the software after the system is connected Log book; periodic controls register for quick viewing of the event log Test for the monitoring of the isolation between battery potential and earth The functionality and duration tests are freely programmable
Fitted on mimic panel
Fitted on batteries
GREEN LED ON STEADY The battery is in good condition and its operating voltage is correct GREEN LED ON STEADY+RED LED FLASHING SLOW The battery voltage is below the normal operating threshold and may unbalance the entire battery pack. GREEN LED ON STEADY+RED LED FLASHING FAST The battery voltage is above the normal operating threshold and may unbalance the entire battery pack resulting in overheating and consequent damage to the battery FLASHING GREEN AND RED LEDS The temperature inside the box is above operating threshold (over 38°C)
CHART E30 fire-resistant line RS 485 Bus Line Fireproof compartment Floor electric control board switch
ML - Line monitor MF - Phase monitor FRDB - Fire-resistant rack control board
LN 230Vac
Ground Floor
MDL-L - Fixture addressing module
First Floor
Floor electric control board
STEP N/M - Non-maintained LYRA EVO M - Maintained Ordinary lighting fixture 2X18W Ordinary lighting fixture 4X18W
Basement
LN 230Vac
27
2828
CENTRALIZED SUPERVISION SYSTEMS
Spy Center LPS
TM
Spy Center LPS is the Linergy power and centralised control system for low power. A
C
B
A=600 mm B=1000 mm C=250 mm
28
documentation@linergy.it | direct assistance (+39) 0735 597454
2828
CENTRALIZED SUPERVISION SYSTEMS
Spy Center LPS Expandable, flexible and modular system with 4/8 circuits each 700 W and 1500 W and a maximum of 20 units installed per circuit
Wall mounting
Low installation costs with final installed circuits that do not require E30 fire resistant cables if installed in the fire compartment
Weight: 60.5 kg without batteries
Advanced and simple to use system for monitoring a single device and/or the circuit without additional wiring. Freely programmable lighting circuits and devices, remote maintenance and viewing, lamp operation check and monitoring via the SC LAN card included
Supply voltage: 230V 50Hz or 3x400V 50Hz monitoring devices included
Decentralised power system compliant with EN 50171 Compliant with EN 50172 for the safety of lighting systems With automatic monitoring system in accordance with EN 62034 to check the operation of all devices connected at regular intervals Independent system with mixed mode operation non maintained N/M and maintained M The tests are stored for a period of 5 years through an integrated electronic event log Foreign language compatible Up to 20 devices can be managed per end circuit 4/8 final circuits with mixed mode operation maintained M and/or non maintained N/M
Body: steel RAL 7035 Dimensions: 600 x 1000 x 250 mm IP54 protection rating Protection class: I
Battery: 216V (18x12V / 7Ah 45 kg or 18x12V / 12Ah 70 kg) ORDER CODE
SHORT CODE
DESCRIPTION
SCMDL-L SCMDNIO SCMLE SCMLI SCMF8
A104 A265 A266 A267 A271
MODULE FOR MONITORING INDIVIDUAL EMERGENCY LAMP L EXTERNAL INPUT/OUTPUT MODULE EXTERNAL MODULE FOR LINE MONITORING INTERNAL MODULE FOR LINE MONITORING EXT. MODULE FOR 8-PHASE MONITORING
PACK 1 1 1 1 1
INTERNAL I/O SERIES MODULE 8 potential free inputs Selectable NC/NO 8 relay outputs 230Vdc / 6A Potential free exchange contacts
REMOTE SIGNALLING ON SC PSR SYNOPTIC PANEL System ON System error Battery Network functions Error sound warning
Selectable lamp load according to the type of battery Status information via the display system Inputs freely assigned to each circuit or device Connectivity via RS 485 interface for external line monitor and input bus interfaces
MONITORING MODULE FOR INDIVIDUAL SCMDL-L DEVICE Module addressable from 1 to 20 and supplementary input for ON function by means of 230Vac switch
Ethernet port with TCP/IP protocol for intranet/ internet connection Incorporated web server for remote system management over the internet
29
3030
CENTRALIZED SUPERVISION SYSTEMS
Spy Center LPS BATTERY CURRENT AND CAPACITY Battery 12V / 7Ah
Battery 12V / 12Ah
1h
4,0 A ~ 900 W
7,0 A ~ 1500 W
3h
1,6 A ~ 350 W
3,1 A ~ 670 W
8h
0,8 A ~ 180 W
1,4 A ~ 300 W
First Floor
LN 230Vac
CHART E30 fire-resistant line RS 485 Bus Line
LN 230Vac
Fireproof compartment
Floor electric control board LN 230Vac
MDL-L - Fixture addressing module MF - Phase monitor
Ground Floor
Floor electric control board switch
FRDB - Fire-resistant rack control board PRODIGY N/M - Non-maintained LYRA EVO M - Maintained
Basement
Ordinary lighting fixture 2X18W
30
3030
CENTRALIZED SUPERVISION SYSTEMS
Spy Center LPS
Single-phase output voltage
System + battery combicabinet
Colour touchscreen display
Three- or single-phase power supply
Charger
Integrated Teamviewer for remote management (supervision programming)
Ventilation
18 batteries x Ogiv 12V
Quick activation services thanks to the “user friendly” functions
Efficient battery charge management
ORDER CODE
SHORT CODE
OUTPUT LINES
SCL090P04 SCL090P08
SC 1201 SC 1202
4 8
SCL150P08
SC 1203
8
OUTPUT VOLTAGE
BATTERIES
ACTIVE POWER
DURATION
CABINET WITH BATTERIES
INSTALLATION
1 h - 900 W 3 h - 350 W 1 h - 1500 W 3 h - 670 W
1
Wall
SPY CENTER LPS 230 Vdc (230 Vac with mains)
18 x Pb 12V 7Ah
900 W
18 x Pb 12V 12Ah
1500 W
31
3232
CENTRALIZED SUPERVISION SYSTEMS
Spy Center 24
TM
SPY CENTER 24 is a centralized power supply and control system for 24 Vdc low voltage LED emergency luminaires.
UP TO 8 CIRCUITS WITH MIXED OPERATION MODE N/M AND M OPERATION ON SAME CIRCUIT DIMMABLE MAINTAINED FUNCTION LOCAL EMERGENCY FUNCTION (NO INPUT MODULE REQUIRED) POSSIBILITY OF MONITORING AND CONTROL OF EACH INDIVIDUAL LED LUMINAIRE AUTOMATIC LUMINAIRE ENROLMENT WITH SERIAL NUMBER
420W max active power
HIGH ENERGY SAVING WITH 24V LOW VOLTAGE SYSTEM MANAGEMENT LOW INSTALLATION COSTS WITH CIRCUITS WHICH DO NOT REQUIRE FIRE-RESISTANT CABLES IN FIRE COMPARTMENT
A
C
INFORMATION ON THE STATUS OF THE SYSTEM WITH TEXT DISPLAY ON LCD TOUCH SCREEN AND LED SIGNALLING. FOREIGN LANGUAGE INSERTION OPTION REMOTE PROGRAMMING AND MANAGEMENT OF SUPERVISION WITH ETHERNET CARD INCLUDED
B
10-YEAR BATTERY LIFE EXPECTANCY
A=417mm B=546mm C=147mm
32
documentation@linergy.it | direct assistance (+39) 0735 597454
3232
CENTRALIZED SUPERVISION SYSTEMS
Spy Center 24 TECHNICAL FEATURES
The maximum voltage drop at full load must not exceed 4V
Up to 60 W load per circuit
POWER CAPACITY
Monitoring of 160 separate LED luminaires in 8 final circuits, max. 20 luminaires per circuit
CABLE SECTION 1.5 mm² 60 m 73 m 91 m 121 m 182 m 365 m
60 W 50 W 40 W 30 W 20 W 10 W
5A fuse on each final circuit 7” touch screen for monitoring programming Integration of SPY CENTER 24 into every Ethernet network (LAN)
CABLE SECTION 2.5 mm² 100 m 121 m 152 m 202 m 304 m 562 m
Integrated web server
CENTRAL CONTROL UNIT MANAGEMENT Spy Center 24 is supplied as standard with a web app that can be accessed via any browser for system configuration and management.
ORDER CODE
SHORT CODE
OUTPUT LINES
BATTERIES
ACTIVE POWER
ORDER CODE
SHORT CODE
SC24VCTRL SC24VMDL
A261 A262
SCMF2-S
A097
DURATION
DESCRIPTION
PACK
INTEGRATED CIRCUIT BOARD MODULE FOR MONITORING INDIVIDUAL EMERGENCY LAMP EXT. MODULE FOR MONITORING OF THE 1 CHANGE OVER CONT. PHASE
1 1 1
CHARGE TIME
OUTPUT VOLTAGE
CABINET WITH BATTERIES
INSTALLATION
80% in 12 h
24 Vdc
1
Wall
SPY CENTER24 SC24V12A2
SC 1401
2
2 x Pb 12V 12Ah
120 W
SC24V24A4
SC 1402
4
2 x Pb 12V 24Ah
240 W
SC24V33A6
SC 1403
6
2 x Pb 12V 33Ah
360 W
SC24V33A8
SC 1404
8
2 x Pb 12V 33Ah
420 W
1 h - 120 W 2 h - 80 W 3 h - 60 W 1 h - 240 W 2 h - 160 W 3 h - 120 W 1 h - 360 W 2 h - 220 W 3 h - 160 W 1 h - 420 W 2 h - 240 W 3 h - 180 W
33
3434
CENTRALIZED SUPERVISION SYSTEMS
Spy Center Basic
TM
The SPY CENTER family grows with the new BASIC model; available in a wide range of versions according to installation requirements.
CAN BE USED IN ALL EMERGENCY SYSTEMS AS ENVISIONED BY THE EN 50171 REGULATION OPERATING VERSATILITY THANKS TO ONLINE TECHNOLOGY EASY INSTALLATION AND MAINTENANCE HIGH PEAK CURRENTS FOR MANAGEMENT OF ANY MAINTAINED AND NON-MAINTAINED LOAD EXPANDABILITY OF BATTERIES UNIT FOR 1h - 2h - 3h OF DURATION CUTTING-EDGE MANAGEMENT AND BATTERY SAFEGUARDING BOARD FOR SIGNALLING STATUS AS PER STANDARD ON ALL VERSIONS IN COMPLIANCE WITH EN 50171 ETHERNET SNMP BOARD AVAILABLE ON ALL VERSIONS COMPATIBLE WITH ALL LINERGY CENTRAL BATTERY FIXTURES BATTERIES WITH LIFE EXPECTANCY OF 10 YEARS
The image of the product is purely indicative as the system may vary according to dimensioning.
34
documentation@linergy.it | direct assistance (+39) 0735 597454
3434
CENTRALIZED SUPERVISION SYSTEMS
Spy Center Basic ORDER CODE
SHORT CODE
NOMINAL POWER (VA)
ACTIVE POWER (W)*
DURATION
INPUT/OUTPUT 230 VAC/230 VAC
BATTERY TYPE SEALED
INSTALLATION
SCB010P10 SCB010P20
SC 1501
1000
600
1h
Single-phase/Single-phase
Pb
Tower
SC 1502
1000
600
2h
Single-phase/Single-phase
Pb
Tower
SCB010P30
SC 1503
1000
600
3h
Single-phase/Single-phase
Pb
Tower
SCB020P10
SC 1504
2000
1200
1h
Single-phase/Single-phase
Pb
Tower
SCB020P20
SC 1505
2000
1200
2h
Single-phase/Single-phase
Pb
Tower
SCB020P30
SC 1506
2000
1200
3h
Single-phase/Single-phase
Pb
Tower
SCB030P10
SC 1507
3000
1800
1h
Single-phase/Single-phase
Pb
Tower
SCB030P20
SC 1508
3000
1800
2h
Single-phase/Single-phase
Pb
Tower
SCB030P30
SC 1509
3000
1800
3h
Single-phase/Single-phase
Pb
Tower
SCB050P10
SC 1510
5000
2800
1h
Single-phase/Single-phase
Pb
Tower
SCB050P20
SC 1511
5000
2800
2h
Single-phase/Single-phase
Pb
Tower
SCB050P30
SC 1512
5000
2800
3h
Single-phase/Single-phase
Pb
Tower
SCB060P10
SC 1513
6000
4200
1h
Single-phase/Single-phase
Pb
Tower
SCB060P20
SC 1514
6000
4200
2h
Single-phase/Single-phase
Pb
Tower
SCB060P30
SC 1515
6000
4200
3h
Single-phase/Single-phase
Pb
Tower
SCB080P10
SC 1516
8000
5600
1h
Single-phase/Single-phase
Pb
Tower
SCB080P20
SC 1517
8000
5600
2h
Single-phase/Single-phase
Pb
Tower
SCB080P30
SC 1518
8000
5600
3h
Single-phase/Single-phase
Pb
Tower
SCB100P10
SC 1519
10000
7000
1h
Single-phase/Single-phase
Pb
Tower
SCB100P20
SC 1520
10000
7000
2h
Single-phase/Single-phase
Pb
Tower
SCB100P30
SC 1521
10000
7000
3h
Single-phase/Single-phase
Pb
Tower
* The contactors of the SPY CENTER BASIC range have been specifically dimensioned for the centralized power supply of the emergency lighting. For this reason, in compliance with that required by EN 50171, the machine must be dimensioned maintaining a margin of power of 20% with respect to the same. On request, dimensioning is performed for the contactors with TRI-PHASE INPUT/OUTPUT
TECHNICAL FEATURES SPY CENTER BASIC contactors suitable for use in emergency systems made in compliance with EN 50171 Possibility of installation in any technical room in complete safety on the basis of the EN 50272-2 regulation Maintenance-free sealed lead batteries ONLINE DOUBLE CONVERSION type intervention time = 0 Different outputs for MAINTAINED (M) and NONMAINTAINED (N/M) load Automatic BYPASS in case of contactor fault High overload capacity as per EN 50171
DOUBLE OUTPUT Part of the load is powered without interruption MAINTAINED M LINE, while the remaining part of the load will be only powered when there is a power cut SE LINE. Double output device as per standard in all SPY CENTER BASIC versions
Maintained M
Non-maintained N/M
BATTERY LOG The battery LOG is a system developed for the monitoring of lead sealed batteries present inside SPY CENTER BASIC central battery system. The system consists of TRANSMITTER modules connected to each battery and a module mounted on the Spy Center Basic battery box. Both the TRANSMITTER module and the RECEIVER module have an LED for signaling the operating status of each single unit.
Input and output breaker as per standard on all versions Type of installation Tower with movement EPO (emergency power off) RELEASE BUTTON as per standard on all versions LIQUID CRYSTAL DISPLAY with the main info regarding contactor status
Fitted on batteries
Fitted on battery box
ORDER CODE
SHORT CODE
DESCRIPTION
SCBLAN SCBMOD SCBAT-RX-SCB SCBAT-TX SCBCONT * SCBMLE
A125 A126 A259 A260 A263 A264
BOARD UPS ONLINE SIGNALLING MODULE BOARD FOR SPY CENTER BASIC BATTERY MONITORING SYSTEM SPY CENTER BASIC RECEIVER BATTERY MONITORING SYSTEM TRANSMITTER RELAY CONTACT EXTERNAL MODULE FOR LINE MONITORING
PACK 1 1 1 1 1 1
* Note: in combination with Spy Center Basic > 5000 VA only
35
3636
GUIDE TO THE EMERGENCY LUMINAIRES
Send an e-mail to documentation@linergy.it and you will receive a link to download the constantly updated technical-sales material. NOTE Specify in object: “Documentation”
3636
GUIDE TO THE EMERGENCY LUMINAIRES
WHAT THEY ARE Emergency lights are used for safety backup lighting when normal lighting fails due to power outages. WHY USE THEM The Law and various technical standards require the presence of safety lighting in all places of work, in order to avoid discomfort and specially to ensure the security and the safety of persons, in cases of failure or power supply outages, fires or other accidents. HOW TO CHOOSE THEM Choosing the right emergency lights requires the knowledge of various types and essential characteristics. TYPE OF OPERATION Non-maintained models or N/M type The light is switch on only if there is the power supply to the light is disrupted. Models with maintained functioning or M type The light remains on constantly if the power grid is operational or not. This type of operation is suitable for illuminating a pictogram to indicate the escape route. Lighting models or L type The light fixtures are equipped with a power supply/driver and the light source, they do not have batteries. They are powered by a mains voltage or backup systems. They may have different power supply voltages according to the model; for example, 230Vac, 110Vac or 48Vdc.
PROTECTION RATING The degree of protection IPxx indicates the mechanical protection of the light fixture to external agents. The first digit indicates the degree of protection against the entrance of solid bodies, the second digit is against liquid; for example, IP65 light fixtures are protected against dust and water streams. LUMINOSITY The luminous flux of the lamp emitted during emergencies is a fundamental parameter. It is used, together with the radiation pattern, to design the lighting of the system. It represents the amount of light energy emitted by the source in a unit of time, the unit of measurement is the lm (lumens), and it has nothing to do with Watts, the number of LEDs or battery size. The emergency flux of the fixture always shows the emergency flux, while two fluxes are indicated for SA-type fixtures. BATTERY LIFE Regulations require different duration according to the various environments: 30’ (minutes), 1h, 1h30’, 2h. Then there are also products having 3 hours of battery life and more. The batteries must be replaced when nominal battery life is no longer ensured due to degradation. CHARGING TIME The “Charging time” indicates the time needed to recharge the battery in order to ensure its nominal duration. As a rule, the product standard indicates a charging time of 24 hours. In various environments laws and regulations indicate devices with charging in 12h.
PRODUCT CODES KEY PRODUCT AL Atex Led AS Astra BG Big One CE Cristal Evo CM Cometa CR/CS Cristal CW Cristal Wall DL Dual DU Dual Led EF/EU Evolution Flu EI Euroinverter EL/ES Evolution Led FT Fastinverter L / Alta Resa T8 FX Fox IC Ice IT Icetek KL K-Led LD/LS Ledy LI/LH Led Inverter LV Lyra Evo LX Lexit MB/ML Moon Led NL Nanoled OR Orion PR/PS Prodigy QU Qube SB Seven Glass SC Spy Center SC24 Spy Center24 SCB Spy Center Basic SCL Spy Center LPS SF Seven Plus SG Seven Plus Led SS Spy System ST Step SW Swing VD Vip Led VE Vialed Evo VH Vialed High VN Vialed Net VT/VU Vialed Tube VW Vialed Wall
POWER
BATTERY
DURATION
TYPE
COLOUR
VERSION
FUNCTIONS
FLUX
100 - 1 led 200 - 2 led 300 - 3 led 04 Watt 06 Watt 08 Watt 11 Watt 18 Watt 24 Watt
L Lithium
10 1h 13 1h 30’ 20 2h 30 3h
A Maintained M
B White
S Standard
T Energy Test
H High Flux
E Non Maintained N/M
G Grey
R Rest Mode
C Centralized Supervision Spy System
HH Highest Flux
N Nickel Cadmium Nickel Metal Hydrate
I Inhibition
I Lighting L
P Lead
M Movie
M Movie
F Li-FePO4
SC Centralized Supervision Spy Center SC24 Centralized Supervision Spy Center 24V B Energy Test Touch D Dali W Spy System Wireless
Example of a code for a high flux Prodigy luminaire
PR 24
F
10
E
B
R
T - H 37
3838
GUIDE TO THE EMERGENCY LUMINAIRES
INHIBIT Inhibitory connection
REST MODE Rest Mode connection
ENERGY TEST Local self-diagnostics
SPY SYSTEM Centralised self-diagnosis with control units
SPY SYSTEM WIRELESS Centralized wireless self-diagnosis with supervision units
DALI Centralised self-diagnosis with third-party DALI systems
CENTRAL BATTERY Light fittings powered via certified emergency backup
SPY CENTER Light fittings powered by Spy Center certified emergency backup unit with single-point control
SPY CENTER 24 Light fittings powered by Spy Center 24 certified emergency backup unit
38
It is possible to inhibit the emergency system functioning by utilizing the inhibition function. It is a switch which is connected to the luminaire’s A and B terminals (fig. 1). This is a low-cost solution, but it has a disadvantage: in the event of a breakdown on the inhibition line, or if the switch is inadvertently left on the “OFF” position, the system is permanently inhibited and consequently the luminaires do not switch on. To remedy these problems, the regulations envision the “rest mode” function, by which a centralized control device is connected to terminals A and B instead of a switch (fig. 2). It manages the inhibition of the luminaires and keeps them active and selfrestorable in the event of a blackout. If it is linked with “ENERGY TEST” ceiling lights this fixture also allows you to carry out the functionality test of the emergency system.
The Linergy light fittings of the “Energy Test” series is equipped with a microprocessor for constant monitoring and prompt reporting of any malfunction due to a flat battery or light source. FUNCTION TEST: every 14 days the light fitting switches on the light source for 20 seconds to ensure its functionality. DURATION TEST: every 84 days a power failure is simulated, the battery is completely discharged and the lamp’s nominal duration is checked.
The Spy System series of Linergy light fittings are self-diagnostic lamps as described above, that can be connected to and managed by their related control units.
The luminaires of the Spy System Wireless series are lamps with self-diagnosis, which can be managed and controlled by the Spy System units by means of wireless communication with mesh network technology.
DALI (Digital Addressable Lighting Interface) is an international standard communication protocol for the management of lighting systems, both ordinary and emergency. For further information see p. 22.
Supplied only with the power supply/driver and the light source, these are certified light fittings that can be connected to various type of emergency backup units. Generally powered at 230Vac, they are able to ensure good lighting performance.
Specific series of lamps to be connected to the Spy Center emergency backup units, as they feature an internal control and monitoring module with PLC technology, and, of course, to the power supply and light source.
LED light fittings, with drivers and addressing and communication module connectable to Spy Center 24 series emergency backup units at extra-low voltages of 24Vdc. Each product is powered by the emergency power unit and features PLC control.
3838
GUIDE TO THE EMERGENCY LUMINAIRES
A
A
A
B
B
A
A
B
B
A
A
B
B
A
A
B
B
Fig. 1 INHIBIT Diagram Connection with Inhibition For correct installation, the switch must be accessible only to staff authorized for maintenance operations.
Fig. 2 REST MODE Diagram Connection with Rest Mode (Compliant connection)
B
Commander - For further information, see page 153
MOVIE Movie version public event The “Movie” range of ceiling lights are recommended for cinemas and theatres. In normal conditions, the lighting provided does disturb the show but is still able to ensure visibility of the exit routes. In the event of an emergency, the luminaire provides maximum brightness. These luminaires utilize LED technology.
ENERGY TEST TOUCH The “Touch” version makes it possible to activate several special functions by simply touching the sensitive area of the luminaire: manual start of functional and duration tests; memory reset; rest mode. All this in addition to the standard functions of an “Energy Test” luminaire.
SYNCHRONIZATION PROCEDURE FOR FUNCTIONAL AND AUTONOMY TESTS Wherever possible, disconnect the luminaire reflector including electronic board, battery and Led card/fluorescent tube - from the wall base (traditional luminaires with comb connection terminal block). In all other cases (inverter and luminaires with extractable terminal block) open the jumper of terminals A - B. Wait 5 seconds. Replace the reflector on the wall base or close the jumper on terminals A - B. Note: This operation must be performed annually on each luminaire. Example: If you want the luminaire to perform tests in the morning, the operation must be performed in the daytime (e.g. 9 a.m.).
39
4040
GUIDE TO THE EMERGENCY LUMINAIRES
A TECHNICAL GUIDE TO EMERGENCY LIGHTING
STANDBY LIGHTING
SAFETY LIGHTING
Lighting
Exit
Signalling
High-risk activity Anti-panic
STANDBY LIGHTING Allows you to continue with your activity in the absence of normal lighting.
SAFETY LIGHTING
EXIT Illuminates and indicates the exit paths within a place that guide you until you reach a safe area. Features: pictogram on a green background which must cover at least 50% of the surface area it must be rectangular or square its dimensions must be adequate enough to ensure clear visibility. the message must be clear, immediate and respect EN 1838 and ISO 7010 regulations Backlighting (in contrast to external lighting) allows for greater visibility of the pictogram both in normal conditions as well as in the absence of normal lighting. Ceiling lights can be either maintained (M) or nonmaintained (N/M). The latter may be sufficient in places which are lit normally. The visual range, according to EN 1838, is calculated with the formula L = z x h (see page 103). z is a constant with 100 for signs lit externally, 200 for those back-lit.
40
Example: A back-lit sign with height of 16 cm will be visible at a distance equal to 200 times h, i.e. 32 metres. The same sign lit externally will have visibility equal to 100 times h, i.e. 16 metres. Only the height of the pictogram defines its visibility, not its length. HIGH-RISK ACTIVITIES Allows workers to stop performing dangerous operations through the use of correct procedures. The safety lighting for high-risk activities must be 10% of the normal lighting, or at any rate a minimum value of 15 lux. In addition, uniform lighting with ratio between maximum and minimum no greater than 10 is required. ANTI-PANIC Limits the risk of panic caused by sudden darkness. The minimum illumination required, without taking into consideration wall reflections, is 0.5 lux on the ground over the entire area excluding a 50 cm perimeter strip. For the purposes of uniformity, the ratio between maximum and minimum illumination must not exceed a value of 40. This information was updated in compliance with EN 1838 2013.
4040
GUIDE TO THE EMERGENCY LUMINAIRES
• at every safe place in which individuals converge outside the emergency exit. • near to every first-aid site, 5lx • near to every fire fighting device and calling point, 5lx • near to every evacuation device for the disabled • near to shelters and collection points for the disabled • near to the wc for the disabled (near means within 2 m)
ARRANGEMENT OF THE LUMINAIRE DEVICES: • near to every Emergency door • near to every flight of stairs which must receive direct light. • near to every change in level. • on the safety signs on the exit routes lit externally • at every change in direction. • at every corridor crossing.
Vialed Evo Ledy
Orion Lyra Evo
Cristal Wall
Orion
Prodigy
te
ou it r
Ledy
ux
1l
e t th
n idia
of
x ee
th
r
me
a
Prodigy
Lyra Evo
Cristal Evo Orion
Cristal Wall 0.5 Lx on the ground on the entire area with the exclusion of a perimeter strip measuring 50 cm
Lyra Evo
Ledy
41
TY
FIV
E YEA
R
Ledy LEDY
®
ARRAN
W
4242
LED TECHNOLOGY EMERGENCY LUMINAIRES
5 year warranty
LEDY is the first Led emergency luminaire studied with state-of-the-art technology. Fully rechargeable batteries and no maintenance costs.
also available in Touch version
IDEAL FOR INDOOR AND OUTDOOR SETTINGS (hospitals, shops, schools, homes, hotels, settings with refined furnishings) DECORATIVE FRAMES AND TRAYS AVAILABLE C
INSTALLATION: WALL-MOUNTED, FLAG STYLE, CEILING AND RECESSED
A
MAINTENANCE-FREE: LONG-LIFE LED AND LITHIUM BATTERY B
SUPPLIED IN WHITE AS PER STANDARD
IP42 A=303 mm B=173 mm C=49 mm
42
documentation@linergy.it |
IP65
IK08
PACK
12
technical support 334 1133875
4242
LED TECHNOLOGY EMERGENCY LUMINAIRES
Ledy Protection rating IP42 - IP65 - IK08
ELECTRIC CONNECTIONS
Available in the following versions: 1 Led - 2 Led - 3 Led comparable with 6-8W, 11-18W, 24W models
Maintained
Non-Maintained Central battery / Spy Center
Can also be installed onto surfaces that are normally flammable Power supply: 230 Vac 50-60 Hz Maximum battery recharging time: 12 h Compliant with European standards EN 60598-1, EN 60598-2-22
INTERCHANGEABLE PLATE FINISHES AND FRAMES
Photobiological hazard free according to standard EN 62471 Photometric diagrams Range Angles
Range Angles
Range Angles
QUICK COUPLING
1 LED
2 LED
3 LED
The bottom of the ceiling light is set-up for fixing to common boxes used in the electric plant. In addition to knockout rear entrances, three lateral entrances x 16 mm tubes are envisioned. LEDY can be finished aesthetically with the plates and the flush-wall frames in different colours and materials. The many choices of colours and matches allow LEDY to blend with any setting; from the most modern to traditional.
PLATES
FRAMES
LD PL-B White finish
LD PL-N Black finish
LD PL-G Grey finish
LD CO-B White finish
LD CO-N Black finish
LD CO-G Grey finish
LD PL-A Orange finish
LD PL-V Green finish
LD PL-BL Blue finish
LD CO-A Orange finish
LD CO-V Green finish
LD CO-BL Blue finish
LD PL-R Red finish
LD PL-GI Yellow finish
LD PL-O Gold finish
LD CO-R Red finish
LD CO-GI Yellow finish
LD CO-O Gold finish
LD PL-FA Beech wood finish
LD PL-W Wenge finish
LD PL-NO Walnut finish
LD CO-FA Beech wood finish
LD CO-W Wenge finish
LD CO-NO Walnut finish
43
4444
LED TECHNOLOGY EMERGENCY LUMINAIRES
Ledy Pictograms See the “Accessories and spare parts” section on page 154. Visual range with pictogram = 17 m.
ACCESSORIES LD KT CGE Plasterboard and false ceiling fastening kit Kit for fixing the ceiling light on the plasterboard walls and false ceiling. COMMANDER Controller for the remote management of rest mode Commander manages the rest status and carries out tests on the luminaire. On self-test models it allows for centralized control of the self-diagnosis functions.
LDIS01
INC M LD Wall box for recessed installation Dimensions (mm): internal 274 x 144 max external 290 x 160 GRIG04 Protective grating Made in galvanized metal for complete protection of the luminaire body against accidental blows or acts of vandalism. CR KT BLINDO Busway accessory Accessory that allows hook up to the busbar. LD KT SEG Signalling kit With this kit the Ledy can be used as a signalling luminaire in compliance with EN 1838 Standard. Kit of pictograms supplied as standard. SM KT SUP Kit for flag style fastening Bracket for fixing the ceiling light in flag style. KIT 45 GRADI With this bracket, the luminaire can be installed with an inclination of 45°
ORDER CODE
SHORT CODE
CONSUMPTION * (W)
LDIS02
LDIS08
ORDER CODE
SHORT CODE
DESCRIPTION
CRKTBLINDO GRIG04 INCMLD LDKTCGE LDKTSEG SMKTSUP KIT45GRADI LDIS01 LDIS02 LDIS08 LDCO-N LDPL-N LDCO-BL LDPL-BL LDCO-FA LDPL-FA LDCO-G LDPL-G LDCO-O LDPL-O LDCO-V LDPL-V LDCO-NO LDPL-NO LDCO-A LDPL-A LDCO-R LDPL-R LDCO-B LDPL-B LDCO-W LDPL-W LDCO-GI LDPL-GI COMMANDER
A005 A015 A022 A029 A030 A047 A092 A168 A169 A170 A191 A192 A196 A197 A201 A202 A207 A208 A212 A213 A217 A218 A222 A223 A227 A228 A232 A233 A239 A240 A244 A245 A249 A250 CN0001
BUSBAR KIT PROTECTIVE GRATING WALL BOX RECESSED INSTALLATION LEDY PLASTERBOARD AND DROPPED-CEILING FASTENING KIT LEDY SIGNALING KIT LEDY KIT FOR FLAG-STYLE FASTENING CLASP FOR FIXING AT 45 DEGREES PICTOGRAMS FOR LEDY L PICTOGRAMS FOR LEDY R PICTOGRAMS FOR LEDY LW BLACK FINISH FRAME LEDY BLACK FINISH PLATE LEDY BLUE FINISH FRAME LEDY BLUE FINISH PLATE LEDY BEECH WOOD FINISH FRAME LEDY BEECH WOOD FINISH PLATE LEDY GREY FINISH FRAME LEDY GREY FINISH PLATE LEDY GOLD FINISH FRAME LEDY GOLD FINISH PLATE LEDY GREEN FINISH FRAME LEDY GREEN FINISH PLATE LEDY WALNUT WOOD FINISH FRAME LEDY WALNUT WOOD FINISH PLATE LEDY ORANGE FINISH FRAME LEDY ORANGE FINISH PLATE LEDY RED FINISH FRAME LEDY RED FINISH PLATE LEDY CORNICE FINITURA BIANCA LEDY PLACCA FINITURA BIANCA LEDY WENGE WOOD FINISH FRAME LEDY WENGE WOOD FINISH PLATE LEDY YELLOW FINISH FRAME LEDY YELLOW FINISH PLATE LEDY CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
DURATION
TYPE
AVERAGE FLUX N/M (lm)
N/M N/M N/M N/M N/M N/M
72 72 148 148 220 220
M M M M M M
98 80 195 195 300 220
N/M N/M N/M N/M N/M N/M M M M M M M
98 80 195 195 300 220 98 80 195 195 300 220
PACK
FLUX M (lm)
BATTERY
IP 42 INHIBIT LD100L10EBI LD100L30EBI LD200L10EBI LD200L30EBI LD300L10EBI LD300L30EBI
LD 1101 LD 1102 LD 1103 LD 1104 LD 1105 LD 1106
0,7 0,7 0,7 0,7 0,7 0,7
1h 3h 1h 3h 1h 3h
LD100L10ABR LD100L30ABR LD200L10ABR LD200L30ABR LD300L10ABR LD300L30ABR
LD 1201 LD 1202 LD 1203 LD 1204 LD 1205 LD 1206
1,7 1,7 3,7 3,7 5,6 5,6
1h 3h 1h 3h 1h 3h
LD100L10EBRT LD100L30EBRT LD200L10EBRT LD200L30EBRT LD300L10EBRT LD300L30EBRT LD100L10ABRT LD100L30ABRT LD200L10ABRT LD200L30ABRT LD300L10ABRT LD300L30ABRT
LD 1301 LD 1302 LD 1303 LD 1304 LD 1305 LD 1306 LD 1307 LD 1308 LD 1309 LD 1310 LD 1311 LD 1312
0,7 0,7 0,7 0,7 0,7 0,7 1,7 1,7 3,7 3,7 5,6 5,6
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah
REST MODE 98 80 195 195 300 220
Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah
98 80 195 195 300 220
Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah
ENERGY TEST
44
80 10 60 20 12 10 10 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
4444
LED TECHNOLOGY EMERGENCY LUMINAIRES
Ledy ORDER CODE
SHORT CODE
CONSUMPTION * (W)
DURATION
LD100L10EBRC LD100L30EBRC LD200L10EBRC LD200L30EBRC LD300L10EBRC LD300L30EBRC LD100L10ABRC LD100L30ABRC LD200L10ABRC LD200L30ABRC LD300L10ABRC LD300L30ABRC
LD 1501 LD 1502 LD 1503 LD 1504 LD 1505 LD 1506 LD 1507 LD 1508 LD 1509 LD 1510 LD 1511 LD 1512
0,7 0,7 0,7 0,7 0,7 0,7 1,7 1,7 3,7 3,7 5,6 5,6
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
LD100000IBS LD200000IBS LD300000IBS
LD 1901 LD 1902 LD 1903
1,8 3 4,5
LD100000IBS-SC LD200000IBS-SC LD300000IBS-SC
LD 2001 LD 2002 LD 2003
1,8 3 4,5
LD100000IBS-SC24 LD200000IBS-SC24 LD300000IBS-SC24
LD 2101 LD 2102 LD 2103
1,5 2,9 3,1
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
SPY SYSTEM N/M N/M N/M N/M N/M N/M M M M M M M
98 80 195 195 300 220 98 80 195 195 300 220
98 80 195 195 300 220
Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah
CENTRAL BATTERY L L L
98 195 300
L L L
98 195 300
SPY CENTER
SPY CENTER 24 L L L
98 195 300
IP 65 INHIBIT LS100L10EBI LS100L30EBI LS200L10EBI LS200L30EBI LS300L10EBI LS300L30EBI
LS 1101 LS 1102 LS 1103 LS 1104 LS 1105 LS 1106
0,7 0,7 0,7 0,7 0,7 0,7
1h 3h 1h 3h 1h 3h
LS100L10ABR LS100L30ABR LS200L10ABR LS200L30ABR LS300L10ABR LS300L30ABR
LS 1201 LS 1202 LS 1203 LS 1204 LS 1205 LS 1206
1,7 1,7 3,7 3,7 5,6 5,6
1h 3h 1h 3h 1h 3h
LS100L10EBRT LS100L30EBRT LS200L10EBRT LS200L30EBRT LS300L10EBRT LS300L30EBRT LS100L10ABRT LS100L30ABRT LS200L10ABRT LS200L30ABRT LS300L10ABRT LS300L30ABRT
LS 1301 LS 1302 LS 1303 LS 1304 LS 1305 LS 1306 LS 1307 LS 1308 LS 1309 LS 1310 LS 1311 LS 1312
0,7 0,7 0,7 0,7 0,7 0,7 1,7 1,7 3,7 3,7 5,6 5,6
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
LS100L10EBRC LS100L30EBRC LS200L10EBRC LS200L30EBRC LS300L10EBRC LS300L30EBRC LS100L10ABRC LS100L30ABRC LS200L10ABRC LS200L30ABRC LS300L10ABRC LS300L30ABRC
LS 1501 LS 1502 LS 1503 LS 1504 LS 1505 LS 1506 LS 1507 LS 1508 LS 1509 LS 1510 LS 1511 LS 1512
0,7 0,7 0,7 0,7 0,7 0,7 1,7 1,7 3,7 3,7 5,6 5,6
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
LS100000IBS LS200000IBS LS300000IBS
LS 1901 LS 1902 LS 1903
1,8 3 4,5
LS100000IBS-SC LS200000IBS-SC LS300000IBS-SC
LS 2001 LS 2002 LS 2003
1,8 3 4,5
LS100000IBS-SC24 LS200000IBS-SC24 LS300000IBS-SC24
LS 2101 LS 2102 LS 2103
1,5 2,9 3,1
N/M N/M N/M N/M N/M N/M
72 72 148 148 220 220
M M M M M M
98 80 195 195 300 220
N/M N/M N/M N/M N/M N/M M M M M M M
98 80 195 195 300 220 98 80 195 195 300 220
Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah
REST MODE 98 80 195 195 300 220
Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah
98 80 195 195 300 220
Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah
98 80 195 195 300 220
Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah Li-ion 3,7V 1,7Ah Li-ion 3,7V 4Ah
ENERGY TEST
SPY SYSTEM N/M N/M N/M N/M N/M N/M M M M M M M
98 80 195 195 300 220 98 80 195 195 300 220
CENTRAL BATTERY L L L
98 195 300
L L L
98 195 300
SPY CENTER
SPY CENTER 24 L L L
98 195 300
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
45
TY
FIV
E YEA
R
Prodigy
TM
ARRAN
W
4646
LED TECHNOLOGY EMERGENCY LUMINAIRES
THE SLIMMEST LAMP
EVER SEEN ON THE MARKET Reduced energy consumption: only 200 mW *
Patent pending
PRODIGY has been designed to make use of all advantages of Led technology: it is compact, offers surprising brightness, great reliability over time and maximum energy saving.
IDEAL FOR INDOOR AND OUTDOOR SETTINGS (medical surgeries, shops, schools, gyms, homes, hotels)
also available in Touch version
LATEST GENERATION LED, LONG-LIFE LENS STUDIED TO OPTIMISE THE LUMINOUS FLUX Li-FePO4 BATTERY: LASTS TWICE AS LONG AS TRADITIONAL Ni-Cd BATTERIES
C
DECORATIVE FINISHING FRAME SUPPLIED AS PER STANDARD
A
INSTALLATION: WALL, CEILING AND RECESSED B
SUPPLIED IN WHITE AS PER STANDARD * On N/M models with charged battery 5
A=243 mm B=114 mm C=33 mm
46
 documentation@linergy.it |
IP42
IP65
PACK
12
technical support 334 1133875
4646
LED TECHNOLOGY EMERGENCY LUMINAIRES
Prodigy
Protection rating IP42 - IP65
EASY AND QUICK INSTALLATION
Available in the following versions: 10 Led - 20 Led can be compared with 8W-11W and 24W models Duration: 1h - 1.5h - 3h Recharge: 12h Can also be installed onto surfaces that are normally flammable Power supply: 230 Vac 50-60 Hz Compliant with European standards EN 60598-1, EN 60598-2-22 Photobiological hazard free according to standard EN 62471
AVAILABLE WITH VARIOUS FINISHINGS
DEVELOPED FOR THE LED LITHIUM BATTERY: GREAT SAVINGS ECO-SUSTAINABLE: BATTERY DURATION OVER 5 YEARS PERFECT FOR EVERY SETTING
Li-FePO4 Battery SERVICE EFFICIENCY
Li-FePO4 NiMH NiCd Pb LIFETIME
OVER 5 YEARS
ORDER CODE
SHORT CODE
DESCRIPTION
PRODIGYCOLOR
A186
PRODIGY OPTION COLOR
PACK 1
* Code to be entered in the order with specification of the colour selected
47
4848
LED TECHNOLOGY EMERGENCY LUMINAIRES
Prodigy ACCESSORIES
Photometric diagram
PR KT CGE Plasterboard and false ceiling fastening kit Kit for fixing the ceiling light on the plasterboard walls and false ceiling.
COMMANDER Controller for the remote management of rest mode Commander manages the rest status and carries out tests on the luminaire. On self-test models it allows for centralized control of the self-diagnosis functions.
10 LED INC M PR Wall box for recessed installation Dimensions (mm): internal 224.1 x 90.1 max external 230.3 x 102.3
20 LED
INTERRUZIONE LINEA PERMANENTE Con accessorio codice: KITMSINIB da ordinare separatamente
PERMANENT LINE INTERRUPTION REMOVE JUMPER J5
GRIG03 Protective grating Made in galvanized metal for complete protection of the luminaire body against accidental blows or acts of vandalism. J5
J5
J5
J5
RED BLACK
CR KT BLINDO Busway accessory Accessory that allows hook up to the busbar.
With accessory code: KITMSINIB to be ordered separately
PR KT SEG Signalling kit With this kit the Prodigy can be used as a signalling luminaire in compliance with EN 1838. Standard Kit of pictograms supplied as standard.
INHIBITION ELECTRICAL CONNECTION (CODES -EBI) SWITCH
OPTIONAL INHIBITION KIT
RATS 16-20 IP42-IP65 fitting for pipes with diameter of 16 and 20 mm The accessory is supplied with IP65 models and can be ordered separately for IP42 models
J2 AB INHIBITION LINE
SM KT SUP Kit for flag style fastening Bracket for fixing the ceiling light in flag style. ORDER CODE KIT 45 GRADI With this bracket, the luminaire can be installed with an inclination of 45°
INTERRUTTORE
KIT INIBIZIONE OPZIONALE
J2 AB LINEA INIBIZIONE
48
KIT MSINIB Kit composed of cable and connector to make an external inhibition line. To be ordered separately.
CRKTBLINDO GRIG03 INCMPR KITMSINIB PRKTCGE PRKTSEG RATS16-20 SMKTSUP KIT45GRADI PRIS01 PRIS02 PRIS08 PRODIGYCOLOR COMMANDER
SHORT CODE A005 A014 A023 A028 A038 A039 A043 A047 A092 A171 A172 A173 A186 CN0001
DESCRIPTION BUSBAR KIT PROTECTIVE GRATING WALL BOX RECESSED INSTALLATION PRODIGY INHIBITION KIT PLASTERBOARD AND DROPPED-CEILING FASTENING KIT PRODIGY SIGNALING KIT PRODIGY IP42 + IP65 CONNECTOR D=16/20MM KIT FOR FLAG-STYLE FASTENING CLASP FOR FIXING AT 45 DEGREES PICTOGRAM FOR PRODIGY ARROW LEFT PICTOGRAM FOR PRODIGY ARROW RIGHT PICTOGRAM FOR PRODIGY ARROW DOWN PRODIGY OPTION COLOR CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
PACK 80 10 63 1 20 10 1 10 10 1 1 1 1 1
4848
LED TECHNOLOGY EMERGENCY LUMINAIRES
Prodigy Prodigy Energy Test Touch: functional and duration tests in 1 touch PRODIGY with ENERGY TEST TOUCH function, via a touch-sensitive area, provides an “invisible” key to activate certain special functions, thus preserving the aesthetics of the lamp and the IP protection rating with no holes.
To start the test, just press the touch area: 1” for the manual functional test 10” for the manual duration test
To confirm that the touch input was received, the led turns solid red for as long as the area is pressed
The led flashes green: the test is in progress
To interrupt the test, just press the touch area again
NOTE: in the event of a power failure, the lighted lamp in emergency can be put at rest (rest mode) by pressing the touch area for 1” and can be turned back on by pressing it again for 1”
Pictograms: See the “Accessories and spare parts” section on page 154. Visual range with pictogram = 17 m.
PRIS01
PRIS02
PRIS08
49
5050
LED TECHNOLOGY EMERGENCY LUMINAIRES
Prodigy ORDER CODE
SHORT CODE
CONSUMPTION * (W)
DURATION
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
N/M N/M N/M
110 175 280
Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah
110 175 280 110 110 175 175 280 280
Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah
IP 42 INHIBIT 5 5 5
PR08F13EBI PR11F13EBI PR24F13EBI
PR 1101 PR 1102 PR 1103
0,3 0,3 0,3
1,5 h 1,5 h 1,5 h
PR08F30EBR PR11F30EBR PR24F30EBR PR08F10ABR PR08F30ABR PR11F10ABR PR11F30ABR PR24F10ABR PR24F30ABR
PR 1201 PR 1202 PR 1203 PR 1204 PR 1205 PR 1206 PR 1207 PR 1208 PR 1209
0,3 0,3 0,3 2 2 2,2 2,2 2,7 2,7
3h 3h 3h 1h 3h 1h 3h 1h 3h
PR08F13EBR-H PR08F30EBR-H PR11F13EBR-H PR11F30EBR-H PR24F10EBR-H PR24F20EBR-H
PR 1210 PR 1211 PR 1212 PR 1213 PR 1214 PR 1215
0,3 0,3 0,3 0,3 0,3 0,3
1,5 h 3h 1,5 h 3h 1h 2h
PR08F10EBRT PR08F30EBRT PR11F10EBRT PR11F30EBRT PR24F10EBRT PR24F30EBRT PR08F10ABRT PR08F30ABRT PR11F10ABRT PR11F30ABRT PR24F10ABRT PR24F30ABRT
PR 1301 PR 1302 PR 1303 PR 1304 PR 1305 PR 1306 PR 1307 PR 1308 PR 1309 PR 1310 PR 1311 PR 1312
0,2 0,2 0,2 0,2 0,2 0,2 1,8 1,8 2 2 3,6 3,6
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
PR08F13EBRT-H PR08F30EBRT-H PR11F13EBRT-H PR11F30EBRT-H PR24F10EBRT-H PR24F20EBRT-H
PR 1313 PR 1314 PR 1315 PR 1316 PR 1317 PR 1318
0,2 0,2 0,2 0,2 0,2 0,2
1,5 h 3h 1,5 h 3h 1h 2h
PR08F10EBRC PR08F30EBRC PR11F10EBRC PR11F30EBRC PR24F10EBRC PR24F30EBRC PR08F10ABRC PR08F30ABRC PR11F10ABRC PR11F30ABRC PR24F10ABRC PR24F30ABRC
PR 1501 PR 1502 PR 1503 PR 1504 PR 1505 PR 1506 PR 1507 PR 1508 PR 1509 PR 1510 PR 1511 PR 1512
0,3 0,3 0,3 0,3 0,3 0,3 1,9 1,9 2,1 2,1 3,7 3,7
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
PR08F13EBRC-H PR08F30EBRC-H PR11F13EBRC-H PR11F30EBRC-H PR24F10EBRC-H PR24F20EBRC-H
PR 1513 PR 1514 PR 1515 PR 1516 PR 1517 PR 1518
0,3 0,3 0,3 0,3 0,3 0,3
PR08F10EBRW PR08F30EBRW PR11F10EBRW PR11F30EBRW PR24F10EBRW PR24F30EBRW PR08F10ABRW PR08F30ABRW PR11F10ABRW PR11F30ABRW PR24F10ABRW PR24F30ABRW
PR 2401 PR 2402 PR 2403 PR 2404 PR 2405 PR 2406 PR 2407 PR 2408 PR 2409 PR 2410 PR 2411 PR 2412
0,4 0,4 0,4 0,4 0,4 0,4 2 2 2,2 2,2 3,8 3,8
PR08F13EBRW-H PR08F30EBRW-H PR11F13EBRW-H PR11F30EBRW-H PR24F10EBRW-H PR24F20EBRW-H
PR 2413 PR 2414 PR 2415 PR 2416 PR 2417 PR 2418
0,4 0,4 0,4 0,4 0,4 0,4
REST MODE 5 5 5 5 5 5 5 5 5
N/M N/M N/M M M M M M M
160 160 160 160 220 220
REST MODE HIGH FLUX 5 5 5 5 5 5
N/M N/M N/M N/M N/M N/M
280 280 370 370 470 470
Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah
110 110 175 175 280 250 110 110 175 175 280 250
Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah
ENERGY TEST 5 5 5 5 5 5 5 5 5 5 5 5
N/M N/M N/M N/M N/M N/M M M M M M M
160 160 160 160 220 220
ENERGY TEST HIGH FLUX 5 5 5 5 5 5
N/M N/M N/M N/M N/M N/M
280 280 370 370 470 450
Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah
110 110 175 175 280 250 110 110 175 175 280 250
Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah
SPY SYSTEM 5 5 5 5 5 5 5 5 5 5 5 5
N/M N/M N/M N/M N/M N/M M M M M M M
160 160 160 160 220 220
SPY SYSTEM HIGH FLUX 5 5 5 5 5 5
1,5 h 3h 1,5 h 3h 1h 2h
N/M N/M N/M N/M N/M N/M
280 280 370 370 470 450
Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah
110 110 175 175 280 250 110 110 175 175 280 250
Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah
SPY SYSTEM WIRELESS 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
N/M N/M N/M N/M N/M N/M M M M M M M
160 160 160 160 220 220
SPY SYSTEM WIRELESS HIGH FLUX
50
1,5 h 3h 1,5 h 3h 1h 2h
N/M N/M N/M N/M N/M N/M
280 280 370 370 470 450
Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah
5050
LED TECHNOLOGY EMERGENCY LUMINAIRES
Prodigy ORDER CODE
SHORT CODE
CONSUMPTION * (W)
DURATION
PR08F10EBRD PR08F30EBRD PR11F10EBRD PR11F30EBRD PR24F10EBRD PR24F30EBRD PR08F10ABRD PR08F30ABRD PR11F10ABRD PR11F30ABRD PR24F10ABRD PR24F30ABRD PR08000IBS-D PR11000IBS-D PR24000IBS-D
PR 1601 PR 1602 PR 1603 PR 1604 PR 1605 PR 1606 PR 1607 PR 1608 PR 1609 PR 1610 PR 1611 PR 1612 PR 1613 PR 1614 PR 1615
0,2 0,2 0,2 0,2 0,2 0,2 1,8 1,8 2 2 3,6 3,6 1,8 2 3,6
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
PR08F13EBRD-H PR08F30EBRD-H PR11F13EBRD-H PR11F30EBRD-H PR24F10EBRD-H PR24F20EBRD-H
PR 1616 PR 1617 PR 1618 PR 1619 PR 1620 PR 1621
0,2 0,2 0,2 0,2 0,2 0,2
1,5 h 3h 1,5 h 3h 1h 2h
PR08000IBS PR11000IBS PR24000IBS
PR 1901 PR 1902 PR 1903
1,4 2 4,1
PR08000IBS-H PR11000IBS-H PR24000IBS-H
PR 1904 PR 1905 PR 1906
4,2 5 6
PR08000IBS-SC PR11000IBS-SC PR24000IBS-SC
PR 2001 PR 2002 PR 2003
1,4 2 4,1
PR08000IBS-SC-H PR11000IBS-SC-H PR24000IBS-SC-H
PR 2004 PR 2005 PR 2006
4,2 5 6
PR08000IBS-SC24 PR11000IBS-SC24 PR24000IBS-SC24
PR 2101 PR 2102 PR 2103
1,2 2,3 3,1
PR080IBS-SC24-H PR110IBS-SC24-H PR240IBS-SC24-H
PR 2104 PR 2105 PR 2106
3,1 4,6 5,4
TYPE
AVERAGE FLUX N/M (lm)
N/M N/M N/M N/M N/M N/M M M M M M M L L L
110 110 175 175 280 250 110 110 175 175 280 250
FLUX M (lm)
BATTERY
DALI
160 160 160 160 220 220 160 160 220
Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah
DALI HIGH FLUX N/M N/M N/M N/M N/M N/M
280 280 370 370 470 450
Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah
CENTRAL BATTERY 5 5 5
L L L
160 210 350
CENTRAL BATTERY HIGH FLUX 5 5 5
L L L
350 410 480
L L L
160 210 350
SPY CENTER 5 5 5
SPY CENTER HIGH FLUX 5 5 5
L L L
350 410 480
SPY CENTER 24 L L L
120 210 300
SPY CENTER 24 HIGH FLUX L L L
300 430 480
IP 65 INHIBIT 5 5 5
PS08F13EBI PS11F13EBI PS24F13EBI
PS 1101 PS 1102 PS 1103
0,3 0,3 0,3
1,5 h 1,5 h 1,5 h
PS08F30EBR PS11F30EBR PS24F30EBR PS08F10ABR PS08F30ABR PS11F10ABR PS11F30ABR PS24F10ABR PS24F30ABR
PS 1201 PS 1202 PS 1203 PS 1204 PS 1205 PS 1206 PS 1207 PS 1208 PS 1209
0,3 0,3 0,3 2 2 2,2 2,2 2,7 2,7
3h 3h 3h 1h 3h 1h 3h 1h 3h
PS08F13EBR-H PS08F30EBR-H PS11F13EBR-H PS11F30EBR-H PS24F10EBR-H PS24F20EBR-H
PS 1210 PS 1211 PS 1212 PS 1213 PS 1214 PS 1215
0,3 0,3 0,3 0,3 0,3 0,3
N/M N/M N/M
110 175 280
Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah
N/M N/M N/M M M M M M M
110 175 280 110 110 175 175 280 280
Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah
REST MODE 5 5 5 5 5 5 5 5 5
160 160 160 160 220 220
REST MODE HIGH FLUX 5 5 5 5 5 5
1,5 h 3h 1,5 h 3h 1h 2h
N/M N/M N/M N/M N/M N/M
280 280 370 370 470 470
Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
51
5252
LED TECHNOLOGY EMERGENCY LUMINAIRES
Prodigy ORDER CODE
SHORT CODE
CONSUMPTION * (W)
DURATION
PS08F10EBRT PS08F30EBRT PS11F10EBRT PS11F30EBRT PS24F10EBRT PS24F30EBRT PS08F10ABRT PS08F30ABRT PS11F10ABRT PS11F30ABRT PS24F10ABRT PS24F30ABRT
PS 1301 PS 1302 PS 1303 PS 1304 PS 1305 PS 1306 PS 1307 PS 1308 PS 1309 PS 1310 PS 1311 PS 1312
0,2 0,2 0,2 0,2 0,2 0,2 1,8 1,8 2 2 3,6 3,6
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
PS08F13EBRT-H PS08F30EBRT-H PS11F13EBRT-H PS11F30EBRT-H PS24F10EBRT-H PS24F20EBRT-H
PS 1313 PS 1314 PS 1315 PS 1316 PS 1317 PS 1318
0,2 0,2 0,2 0,2 0,2 0,2
1,5 h 3h 1,5 h 3h 1h 2h
PS08F10EBRB PS08F30EBRB PS11F10EBRB PS11F30EBRB PS24F10EBRB PS24F30EBRB PS08F10ABRB PS08F30ABRB PS11F10ABRB PS11F30ABRB PS24F10ABRB PS24F30ABRB
PS 1401 PS 1402 PS 1403 PS 1404 PS 1405 PS 1406 PS 1407 PS 1408 PS 1409 PS 1410 PS 1411 PS 1412
0,2 0,2 0,2 0,2 0,2 0,2 1,8 1,8 2 2 3,6 3,6
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
PS08F13EBRB-H PS08F30EBRB-H PS11F13EBRB-H PS11F30EBRB-H PS24F10EBRB-H PS24F20EBRB-H
PS 1413 PS 1414 PS 1415 PS 1416 PS 1417 PS 1418
0,2 0,2 0,2 0,2 0,2 0,2
1,5 h 3h 1,5 h 3h 1h 2h
PS08F10EBRC PS08F30EBRC PS11F10EBRC PS11F30EBRC PS24F10EBRC PS24F30EBRC PS08F10ABRC PS08F30ABRC PS11F10ABRC PS11F30ABRC PS24F10ABRC PS24F30ABRC
PS 1501 PS 1502 PS 1503 PS 1504 PS 1505 PS 1506 PS 1507 PS 1508 PS 1509 PS 1510 PS 1511 PS 1512
0,3 0,3 0,3 0,3 0,3 0,3 1,9 1,9 2,1 2,1 3,7 3,7
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
PS08F13EBRC-H PS08F30EBRC-H PS11F13EBRC-H PS11F30EBRC-H PS24F10EBRC-H PS24F20EBRC-H
PS 1513 PS 1514 PS 1515 PS 1516 PS 1517 PS 1518
0,3 0,3 0,3 0,3 0,3 0,3
PS08F10EBRW PS08F30EBRW PS11F10EBRW PS11F30EBRW PS24F10EBRW PS24F30EBRW PS08F10ABRW PS08F30ABRW PS11F10ABRW PS11F30ABRW PS24F10ABRW PS24F30ABRW
PS 2401 PS 2402 PS 2403 PS 2404 PS 2405 PS 2406 PS 2407 PS 2408 PS 2409 PS 2410 PS 2411 PS 2412
0,4 0,4 0,4 0,4 0,4 0,4 2 2 2,2 2,2 3,8 3,8
PS08F13EBRW-H PS08F30EBRW-H PS11F13EBRW-H PS11F30EBRW-H PS24F10EBRW-H PS24F20EBRW-H
PS 2413 PS 2414 PS 2415 PS 2416 PS 2417 PS 2418
0,4 0,4 0,4 0,4 0,4 0,4
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
ENERGY TEST 5 5 5 5 5 5 5 5 5 5 5 5
N/M N/M N/M N/M N/M N/M M M M M M M
110 110 175 175 280 250 110 110 175 175 280 250
160 160 160 160 220 220
Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah
ENERGY TEST HIGH FLUX 5 5 5 5 5 5
N/M N/M N/M N/M N/M N/M
280 280 370 370 470 450
Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah
110 110 175 175 280 250 110 110 175 175 280 250
Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah
ENERGY TEST TOUCH N/M N/M N/M N/M N/M N/M M M M M M M
160 160 160 160 220 220
ENERGY TEST TOUCH HIGH FLUX N/M N/M N/M N/M N/M N/M
280 280 370 370 470 450
Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah
110 110 175 175 280 250 110 110 175 175 280 250
Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah
SPY SYSTEM 5 5 5 5 5 5 5 5 5 5 5 5
N/M N/M N/M N/M N/M N/M M M M M M M
160 160 160 160 220 220
SPY SYSTEM HIGH FLUX 5 5 5 5 5 5
1,5 h 3h 1,5 h 3h 1h 2h
N/M N/M N/M N/M N/M N/M
280 280 370 370 470 450
Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah
110 110 175 175 280 250 110 110 175 175 280 250
Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah
SPY SYSTEM WIRELESS 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
N/M N/M N/M N/M N/M N/M M M M M M M
160 160 160 160 220 220
SPY SYSTEM WIRELESS HIGH FLUX
52
1,5 h 3h 1,5 h 3h 1h 2h
N/M N/M N/M N/M N/M N/M
280 280 370 370 470 450
Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah
5252
LED TECHNOLOGY EMERGENCY LUMINAIRES
Prodigy ORDER CODE
SHORT CODE
CONSUMPTION * (W)
DURATION
PS08F10EBRD PS08F30EBRD PS11F10EBRD PS11F30EBRD PS24F10EBRD PS24F30EBRD PS08F10ABRD PS08F30ABRD PS11F10ABRD PS11F30ABRD PS24F10ABRD PS24F30ABRD PS08000IBS-D PS11000IBS-D PS24000IBS-D
PS 1601 PS 1602 PS 1603 PS 1604 PS 1605 PS 1606 PS 1607 PS 1608 PS 1609 PS 1610 PS 1611 PS 1612 PS 1613 PS 1614 PS 1615
0,2 0,2 0,2 0,2 0,2 0,2 1,8 1,8 2 2 3,6 3,6 1,8 2 3,6
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
PS08F13EBRD-H PS08F30EBRD-H PS11F13EBRD-H PS11F30EBRD-H PS24F10EBRD-H PS24F20EBRD-H
PS 1616 PS 1617 PS 1618 PS 1619 PS 1620 PS 1621
0,2 0,2 0,2 0,2 0,2 0,2
1,5 h 3h 1,5 h 3h 1h 2h
PS08000IBS PS11000IBS PS24000IBS
PS 1901 PS 1902 PS 1903
1,4 2 4,1
PS08000IBS-H PS11000IBS-H PS24000IBS-H
PS 1904 PS 1905 PS 1906
4,1 5 6
PS08000IBS-SC PS11000IBS-SC PS24000IBS-SC
PS 2001 PS 2002 PS 2003
1,4 2 4,1
PS08000IBS-SC-H PS11000IBS-SC-H PS24000IBS-SC-H
PS 2004 PS 2005 PS 2006
4,1 5 6
PS08000IBS-SC24 PS11000IBS-SC24 PS24000IBS-SC24
PS 2101 PS 2102 PS 2103
1,2 2,3 3,1
PS080IBS-SC24-H PS110IBS-SC24-H PS240IBS-SC24-H
PS 2104 PS 2105 PS 2106
3,1 4,6 5,4
TYPE
AVERAGE FLUX N/M (lm)
N/M N/M N/M N/M N/M N/M M M M M M M L L L
110 110 175 175 280 250 110 110 175 175 280 250
FLUX M (lm)
BATTERY
DALI
160 160 160 160 220 220 160 160 220
Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah
DALI HIGH FLUX N/M N/M N/M N/M N/M N/M
280 280 370 370 470 450
Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah Li-FePO4 3,2V 3Ah Li-FePO4 3,2V 4,5Ah
CENTRAL BATTERY 5 5 5
L L L
160 210 350
CENTRAL BATTERY HIGH FLUX 5 5 5
L L L
350 410 480
L L L
160 210 350
SPY CENTER 5 5 5
SPY CENTER HIGH FLUX 5 5 5
L L L
350 410 480
SPY CENTER 24 L L L
120 210 300
SPY CENTER 24 HIGH FLUX L L L
300 430 480
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
53
TY
FIV
E YEA
R
Evolution Led
®
ARRAN
W
5454
LED TECHNOLOGY EMERGENCY LUMINAIRES
DISPONIBILE ANCHE High flux IN ALTRI COLORI up to 1300lm
With EVOLUTION LED Linergy has created a luminaire which is the natural complement to LEDY. Technologically ground breaking and aesthetically impeccable, it has an invaluable feature: a very affordable price.
PERFECT FOR LARGE INDOOR AND OUTDOOR ENVIRONMENTS (hospitals, technical premises, shops, schools, gyms, homes, hotels) D
E
DECORATIVE FRAMES AND PLATES ARE AVAILABLE IN MANY COLOURS INSTALLATION: WALL-MOUNTED, FLAG STYLE, CEILING AND RECESSED
C A
MOVIE VERSION FOR CINEMAS AND THEATRES EASY TO ASSEMBLE AND INSTALL B
SUPPLIED IN WHITE AS PER STANDARD
IP42 A=350 mm B=177 mm C=52 mm D=25mm E=20mm
54
documentation@linergy.it |
IP65
IK08
PACK
10
technical support 334 1133875
5454
LED TECHNOLOGY EMERGENCY LUMINAIRES
Evolution Led Protection rating IP42 - IP65 Available in versions 6, 8, 11, 18, 24 W
INTERCHANGEABLE PLATES AND FRAMES Evolution Led has an interchangeable system
Can also be installed onto surfaces that are normally flammable
PLATE
Power supply: 230 Vac 50-60 Hz Maximum battery recharging time: 12 h
UPPER FRAME
Compliant with European standards EN 60598-1, EN 60598-2-22
LOWER FRAME
Photobiological hazard free according to standard EN 62471
The lamp can be customised aesthetically with the plates and trims made of different colours and materials. The many choices of colours and combinations allow EVOLUTION LED to blend in with any environment, from the most modern to traditional.
PLATES
FRAMES
EL PL-B White finish
EL PL-N Black finish
EL PL-G Grey finish
EL CO SUP-B EL CO INF-B White finish
EL CO SUP-N EL CO INF-N Black finish
EL CO SUP-G EL CO INF-G Grey finish
EL PL-A Orange finish
EL P-V Green finish
EL PL-BL Blue finish
EL CO SUP-A EL CO INF-A Orange finish
EL CO SUP-V EL CO INF-V Green finish
EL CO SUP-BL EL CO INF-BL Blue finish
EL PL-R Red finish
EL PL-GI Yellow finish
EL PL-O Gold finish
EL CO SUP-R EL CO INF-R Red finish
EL CO SUP-GI EL CO INF-GI Yellow finish
EL CO SUP-O EL CO INF-O Gold finish
EL PL-FA Beech wood finish
EL PL-W Wenge finish
EL PL-NO Walnut finish
EL CO SUP-FA EL CO INF-FA Beech wood finish
EL CO SUP-W EL CO INF-W Wenge finish
EL CO SUP-NO EL CO INF-NO Walnut finish
55
5656
LED TECHNOLOGY EMERGENCY LUMINAIRES
Evolution Led ACCESSORIES EL KT CGE Plasterboard and false ceiling fastening kit Kit for wall-flush installation
Pictograms See the “Accessories and spare parts” section on page 154. Visual range with pictogram = 21 m.
ST KT CGE Plasterboard and false ceiling fastening kit Kit for semi-recessed installation
ELIS01 COMMANDER Controller for the remote management of rest mode Commander manages the rest status and carries out tests on the luminaire. On self-test models it allows for centralized control of the self-diagnosis functions.
RTCA16 Tube/conduit fitting Practical fitting for use of tube measuring 16 mm for the entrance of cables towards the ceiling light. Dimensions (mm): internal 17.5 x 6.5 max external 20 x 10, h 32 INC M EL Wall box for recessed installation Dimensions (mm): internal 334 x 161.5 max external 346.4 x 173.9 GRIG04 Protective grating Made in galvanized metal for complete protection of the luminaire body against accidental blows or acts of vandalism.
CR KT BLINDO Busway accessory Accessory that allows hook up to the busbar.
EL KT SEG Signalling kit With this kit, the Evolution can be used like a signalling luminaire in compliance with EN 1838 Standard. Kit of pictograms supplied as standard.
SM KT SUP Kit for flag style fastening Bracket for fixing the ceiling light in flag style.
KIT 45 GRADI With this bracket, the luminaire can be installed with an inclination of 45°
EL PLG-B Large white finishing plate* Ideal for wall recess installations with box and for false ceiling and plasterboard installation. * Available in black and grey on request (see table of codes on the right)
56
ELIS02
ELIS08
ORDER CODE
SHORT CODE
DESCRIPTION
CRKTBLINDO
A005
BUSBAR KIT
80
ELKTCGE
A009
PLASTERBOARD AND DROPPED-CEILING FASTENING KIT
20
ELKTSEG
A010
SIGNALING KIT
10
GRIG04
A015
PROTECTIVE GRATING
10
INCMEL
A020
WALL BOX RECESSED INSTALLATION EVOLUTION
20
INCMST
A024
WALL BOX RECESSED INSTALLATION STEP
50
SMKTSUP
A047
KIT FOR FLAG-STYLE FASTENING
10
KIT45GRADI
A092
CLASP FOR FIXING AT 45 DEGREES
10
ELIS01
A155
PICTOGRAMS FOR EVOLUTION L
1
ELIS02
A156
PICTOGRAMS FOR EVOLUTION R
1
ELIS08
A157
PICTOGRAMS FOR EVOLUTION LW
1 1
PACK
ELCOINF-N
A188
LOWER FRAME BLACK FOR EVOLUTION
ELCOSUP-N
A189
UPPER FRAME BLACK FOR EVOLUTION
1
ELPL-N
A190
BLACK PLATE FOR EVOLUTION
1
ELCOINF-BL
A193
LOWER FRAME BLUE FOR EVOLUTION
1
ELCOSUP-BL
A194
UPPER FRAME BLUE FOR EVOLUTION
1
ELPL-BL
A195
BLUE PLATE FOR EVOLUTION
1
ELCOINF-FA
A198
LOWER FRAME BEECH WOOD FOR EVOLUTION
1
ELCOSUP-FA
A199
UPPER FRAME BEECH WOOD FOR EVOLUTION
1
ELPL-FA
A200
BEECH WOOD PLATE FOR EVOLUTION
1
ELCOINF-G
A204
LOWER FRAME GREY FOR EVOLUTION
1
ELCOSUP-G
A205
UPPER FRAME GREY FOR EVOLUTION
1 1
ELPL-G
A206
GREY PLATE FOR EVOLUTION
ELCOINF-O
A209
LOWER FRAME GOLD FOR EVOLUTION
1
ELCOSUP-O
A210
UPPER FRAME GOLD FOR EVOLUTION
1
ELPL-O
A211
GOLD PLATE FOR EVOLUTION
1
ELCOINF-V
A214
LOWER FRAME GREEN FOR EVOLUTION
1
ELCOSUP-V
A215
UPPER FRAME GREEN FOR EVOLUTION
1
ELPL-V
A216
GREEN PLATE FOR EVOLUTION
1
ELCOINF-NO
A219
LOWER FRAME WALNUT FOR EVOLUTION
1
ELCOSUP-NO
A220
UPPER FRAME WALNUT FOR EVOLUTION
1
ELPL-NO
A221
WALNUT PLATE FOR EVOLUTION
1
ELCOINF-A
A224
LOWER FRAME ORANGE FOR EVOLUTION
1
ELCOSUP-A
A225
UPPER FRAME ORANGE FOR EVOLUTION
1
ELPL-A
A226
ORANGE PLATE FOR EVOLUTION
1
ELCOINF-R
A229
LOWER FRAME RED FOR EVOLUTION
1
ELCOSUP-R
A230
UPPER FRAME RED FOR EVOLUTION
1
ELPL-R
A231
RED PLATE FOR EVOLUTION
1
ELCOINF-B
A235
LOWER FRAME WHITE FOR EVOLUTION
1
ELCOSUP-B
A236
UPPER FRAME WHITE FOR EVOLUTION
1
ELPL-B
A237
WHITE PLATE FOR EVOLUTION
1 1
ELPLG-B
A238
WHITE BIG PLATE FOR EVOLUTION
ELCOINF-W
A241
LOWER FRAME WENGE FOR EVOLUTION
1
ELCOSUP-W
A242
UPPER FRAME WENGE FOR EVOLUTION
1
ELPL-W
A243
WENGE PLATE FOR EVOLUTION
1
ELCOINF-GI
A246
LOWER FRAME YELLOW FOR EVOLUTION
1
ELCOSUP-GI
A247
UPPER FRAME YELLOW FOR EVOLUTION
1
ELPL-GI
A248
YELLOW PLATE FOR EVOLUTION
1
COMMANDER
CN0001
CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
1
5656
LED TECHNOLOGY EMERGENCY LUMINAIRES
Evolution Led ELECTRIC CONNECTIONS
Photometric diagrams Range Angles
B A
230~
SE N/M models
M models
COMMANDER
230~ SE
230~ SA
B A COMMANDER
10 LED
INSTALLATION VERSATILITY Evolution Led can be wall-mounted, recessed or flush-wall installed. Fits perfectly also into the Step or wall-mounting box for semi-recessed installation. 52 mm
30 mm
10 mm
Range Angles
20 LED Range Angles
Wall-mounted
Recessed onto STEP box
Recessed onto EVOLUTION box
40 LED Range Angles
INSTALLING THE IP65 VERSION The appliance is equipped with a pierceable membrane to ensure IP65 protection rating. Installation of the external visible pipes (Ø 16 mm) is simplified in this way because no tools or pressfits are necessary.
40 LED -HH codes
57
5858
LED TECHNOLOGY EMERGENCY LUMINAIRES
Evolution Led ORDER CODE
SHORT CODE
CONSUMPTION * (W)
DURATION
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
N/M N/M N/M N/M N/M N/M N/M N/M
180 105 185 180 205 185 415 295
Ni-Cd 6V 0,6Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah
N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
185 180 205 185 415 295 680 680 185 180 205 185 415 295 680 680
185 180 205 185 415 295 680 680
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
185 180 205 185 415 295 680 680
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
IP 42 INHIBIT EL08N10EBI EL08N30EBI EL11N10EBI EL11N30EBI EL18N10EBI EL18N30EBI EL24N10EBI EL24N30EBI
EL 1101 EL 1102 EL 1103 EL 1104 EL 1105 EL 1106 EL 1107 EL 1108
0,9 1,2 0,9 1,5 0,9 1,5 1,6 2,6
1h 3h 1h 3h 1h 3h 1h 3h
EL08N10EBR EL08N30EBR EL11N10EBR EL11N30EBR EL18N10EBR EL18N30EBR EL24N10EBR EL24N30EBR EL08N10ABR EL08N30ABR EL11N10ABR EL11N30ABR EL18N10ABR EL18N30ABR EL24N10ABR EL24N30ABR
EL 1201 EL 1202 EL 1203 EL 1204 EL 1205 EL 1206 EL 1207 EL 1208 EL 1209 EL 1210 EL 1211 EL 1212 EL 1213 EL 1214 EL 1215 EL 1216
0,9 1,5 0,9 1,5 1,6 2,6 1,9 3,3 4,2 4 5,2 4,7 8,3 6,5 9,5 10,7
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
EL08N10EBRT EL08N30EBRT EL11N10EBRT EL11N30EBRT EL18N10EBRT EL18N30EBRT EL24N10EBRT EL24N30EBRT EL08N10ABRT EL08N30ABRT EL11N10ABRT EL11N30ABRT EL18N10ABRT EL18N30ABRT EL24N10ABRT EL24N30ABRT
EL 1301 EL 1302 EL 1303 EL 1304 EL 1305 EL 1306 EL 1307 EL 1308 EL 1309 EL 1310 EL 1311 EL 1312 EL 1313 EL 1314 EL 1315 EL 1316
0,9 1,5 1,2 1,9 1,6 2,6 1,9 3,3 4,2 4 5,2 4,7 8,3 6,5 9,5 10,7
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
EL24N10EBRT-H EL24N10EBRT-HH EL24N13EBRT-HH EL24N20EBRT-H
EL 1317 EL 1318 EL 1319 EL 1320
2,6 2,9 3,3 3,3
1h 1h 1,5 h 2h
EL08N10EBRC EL08N30EBRC EL11N10EBRC EL11N30EBRC EL18N10EBRC EL18N30EBRC EL24N10EBRC EL24N30EBRC EL08N10ABRC EL08N30ABRC EL11N10ABRC EL11N30ABRC EL18N10ABRC EL18N30ABRC EL24N10ABRC EL24N30ABRC
EL 1501 EL 1502 EL 1503 EL 1504 EL 1505 EL 1506 EL 1507 EL 1508 EL 1509 EL 1510 EL 1511 EL 1512 EL 1513 EL 1514 EL 1515 EL 1516
0,9 1,5 1,2 1,9 1,6 2,6 1,9 3,3 4,2 4 5,2 4,7 8,3 6,5 9,5 10,7
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
EL24N10EBRC-H EL24N10EBRC-HH EL24N13EBRC-HH EL24N20EBRC-H
EL 1517 EL 1518 EL 1519 EL 1520
2,6 2,9 3,3 3,3
EL08N10EBRW EL08N30EBRW EL11N10EBRW EL11N30EBRW EL18N10EBRW EL18N30EBRW EL24N10EBRW EL24N30EBRW
EL 2401 EL 2402 EL 2403 EL 2404 EL 2405 EL 2406 EL 2407 EL 2408
1,1 1,6 1,3 2 1,71 2,72 2 3,4
REST MODE
ENERGY TEST N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
185 180 205 185 415 295 680 680 185 180 205 185 415 295 680 680
ENERGY TEST HIGH FLUX N/M N/M N/M N/M
870 1300 1300 870
Ni-Cd 6V 2,5Ah Ni-MH 6V 3,3Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah
185 180 205 185 415 295 680 680 185 180 205 185 415 295 680 680
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
SPY SYSTEM N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
185 180 205 185 415 295 680 680
SPY SYSTEM HIGH FLUX 1h 1h 1,5 h 2h
N/M N/M N/M N/M
870 1300 1300 870
Ni-Cd 6V 2,5Ah Ni-MH 6V 3,3Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah
185 180 205 185 415 295 680 680
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
SPY SYSTEM WIRELESS
58
1h 3h 1h 3h 1h 3h 1h 3h
N/M N/M N/M N/M N/M N/M N/M N/M
5858
LED TECHNOLOGY EMERGENCY LUMINAIRES
Evolution Led ORDER CODE
SHORT CODE
CONSUMPTION * (W)
DURATION
EL08N10ABRW EL08N30ABRW EL11N10ABRW EL11N30ABRW EL18N10ABRW EL18N30ABRW EL24N10ABRW EL24N30ABRW
EL 2409 EL 2410 EL 2411 EL 2412 EL 2413 EL 2414 EL 2415 EL 2416
4,3 4,1 5,3 4,8 8,4 6,6 9,6 10,8
EL24N10EBRW-H EL24N10EBRW-HH EL24N13EBRW-HH EL24N20EBRW-H
EL 2417 EL 2418 EL 2419 EL 2420
2,72 3 3,4 3,4
1h 1h 1,5 h 2h
EL08N10EBRD EL08N30EBRD EL11N10EBRD EL11N30EBRD EL18N10EBRD EL18N30EBRD EL24N10EBRD EL24N30EBRD EL08N10ABRD EL08N30ABRD EL11N10ABRD EL11N30ABRD EL18N10ABRD EL18N30ABRD EL24N10ABRD EL24N30ABRD EL08000IBS-D EL11000IBS-D EL18000IBS-D EL24000IBS-D
EL 1601 EL 1602 EL 1603 EL 1604 EL 1605 EL 1606 EL 1607 EL 1608 EL 1609 EL 1610 EL 1611 EL 1612 EL 1613 EL 1614 EL 1615 EL 1616 EL 1617 EL 1618 EL 1619 EL 1620
0,9 1,5 1,2 1,9 1,6 2,6 1,9 3,3 4,2 4 5,2 4,7 8,3 6,5 9,5 10,7 4 4,5 7,5 8,2
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
EL24N10EBRD-H EL24N10EBRD-HH EL24N13EBRD-HH EL24N20EBRD-H EL24000IBSD-H EL24000IBSD-HH
EL 1621 EL 1622 EL 1623 EL 1624 EL 1625 EL 1626
2,6 2,9 3,3 3,3 11 17
1h 1h 1,5 h 2h
EL08N10MBR EL08N30MBR EL11N10MBR EL11N30MBR EL18N10MBR EL18N30MBR EL24N10MBR EL24N30MBR
EL 1701 EL 1702 EL 1703 EL 1704 EL 1705 EL 1706 EL 1707 EL 1708
1,9 1,9 1,9 2,5 1,9 3,6 2,6 4,3
1h 3h 1h 3h 1h 3h 1h 3h
EL08000IBS EL11000IBS EL18000IBS EL24000IBS
EL 1901 EL 1902 EL 1903 EL 1904
3,1 3,5 6,1 6,8
EL24000IBS-H EL24000IBS-HH
EL 1905 EL 1906
8,5 12,8
EL08000IBS-SC EL11000IBS-SC EL18000IBS-SC EL24000IBS-SC
EL 2001 EL 2002 EL 2003 EL 2004
3,1 3,5 6,1 6,8
EL24000IBS-SC-H EL24000IBS-SC-HH
EL 2005 EL 2006
8,5 12,8
EL08000IBS-SC24 EL11000IBS-SC24 EL18000IBS-SC24 EL24000IBS-SC24
EL 2101 EL 2102 EL 2103 EL 2104
3,1 4,6 5,7 7,1
EL240IBS-SC24-H EL240IBS-SC24-HH
EL 2105 EL 2106
9,3 13,9
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
185 180 205 185 415 295 680 680
185 180 205 185 415 295 680 680
BATTERY
SPY SYSTEM WIRELESS 1h 3h 1h 3h 1h 3h 1h 3h
M M M M M M M M
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
SPY SYSTEM WIRELESS HIGH FLUX N/M N/M N/M N/M
870 1300 1300 870
Ni-Cd 6V 2,5Ah Ni-MH 6V 3,3Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah
N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M L L L L
185 180 205 185 415 295 680 680 185 180 205 185 415 295 680 680
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
DALI
185 180 205 185 415 295 680 680 195 215 430 700
DALI HIGH FLUX N/M N/M N/M N/M L L
870 1300 1300 870
MOVIE MOVIE MOVIE MOVIE MOVIE MOVIE MOVIE MOVIE
180 105 185 180 205 185 415 295
Ni-Cd 6V 2,5Ah Ni-MH 6V 3,3Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah 870 1300
MOVIE 15 15 15 15 15 15 15 15
Ni-Cd 6V 0,6Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah
CENTRAL BATTERY L L L L
195 215 430 700
CENTRAL BATTERY HIGH FLUX L L
870 1300
L L L L
195 215 430 700
SPY CENTER
SPY CENTER HIGH FLUX L L
870 1300
SPY CENTER 24 L L L L
235 320 430 630
SPY CENTER 24 HIGH FLUX L L
870 1300
59
6060
LED TECHNOLOGY EMERGENCY LUMINAIRES
Evolution Led ORDER CODE
SHORT CODE
CONSUMPTION * (W)
DURATION
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
N/M N/M N/M N/M N/M N/M N/M N/M
180 105 185 180 205 185 415 295
Ni-Cd 6V 0,6Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah
N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
185 180 205 185 415 295 680 680 185 180 205 185 415 295 680 680
185 180 205 185 415 295 680 680
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
185 180 205 185 415 295 680 680
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
IP 65 INHIBIT ES08N10EBI ES08N30EBI ES11N10EBI ES11N30EBI ES18N10EBI ES18N30EBI ES24N10EBI ES24N30EBI
ES 1101 ES 1102 ES 1103 ES 1104 ES 1105 ES 1106 ES 1107 ES 1108
0,9 1,2 0,9 1,5 0,9 1,5 1,6 2,6
1h 3h 1h 3h 1h 3h 1h 3h
ES08N10EBR ES08N30EBR ES11N10EBR ES11N30EBR ES18N10EBR ES18N30EBR ES24N10EBR ES24N30EBR ES08N10ABR ES08N30ABR ES11N10ABR ES11N30ABR ES18N10ABR ES18N30ABR ES24N10ABR ES24N30ABR
ES 1201 ES 1202 ES 1203 ES 1204 ES 1205 ES 1206 ES 1207 ES 1208 ES 1209 ES 1210 ES 1211 ES 1212 ES 1213 ES 1214 ES 1215 ES 1216
0,9 1,5 0,9 1,5 1,6 2,6 1,9 3,3 4,2 4 5,2 4,7 8,3 6,5 9,5 10,7
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
ES08N10EBRT ES08N30EBRT ES11N10EBRT ES11N30EBRT ES18N10EBRT ES18N30EBRT ES24N10EBRT ES24N30EBRT ES08N10ABRT ES08N30ABRT ES11N10ABRT ES11N30ABRT ES18N10ABRT ES18N30ABRT ES24N10ABRT ES24N30ABRT
ES 1301 ES 1302 ES 1303 ES 1304 ES 1305 ES 1306 ES 1307 ES 1308 ES 1309 ES 1310 ES 1311 ES 1312 ES 1313 ES 1314 ES 1315 ES 1316
0,9 1,5 1,2 1,9 1,6 2,6 1,9 3,3 4,2 4 5,2 4,7 8,3 6,5 9,5 10,7
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
ES24N10EBRT-H ES24N10EBRT-HH ES24N13EBRT-HH ES24N20EBRT-H
ES 1317 ES 1318 ES 1319 ES 1320
2,6 2,9 3,3 3,3
1h 1h 1,5 h 2h
ES08N10EBRC ES08N30EBRC ES11N10EBRC ES11N30EBRC ES18N10EBRC ES18N30EBRC ES24N10EBRC ES24N30EBRC ES08N10ABRC ES08N30ABRC ES11N10ABRC ES11N30ABRC ES18N10ABRC ES18N30ABRC ES24N10ABRC ES24N30ABRC
ES 1501 ES 1502 ES 1503 ES 1504 ES 1505 ES 1506 ES 1507 ES 1508 ES 1509 ES 1510 ES 1511 ES 1512 ES 1513 ES 1514 ES 1515 ES 1516
0,9 1,5 1,2 1,9 1,6 2,6 1,9 3,3 4,2 4 5,2 4,7 8,3 6,5 9,5 10,7
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
ES24N10EBRC-H ES24N10EBRC-HH ES24N13EBRC-HH ES24N20EBRC-H
ES 1517 ES 1518 ES 1519 ES 1520
2,6 2,9 3,3 3,3
REST MODE
ENERGY TEST N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
185 180 205 185 415 295 680 680 185 180 205 185 415 295 680 680
ENERGY TEST HIGH FLUX N/M N/M N/M N/M
870 1300 1300 870
Ni-Cd 6V 2,5Ah Ni-MH 6V 3,3Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah
185 180 205 185 415 295 680 680 185 180 205 185 415 295 680 680
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
SPY SYSTEM N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
185 180 205 185 415 295 680 680
SPY SYSTEM HIGH FLUX
60
1h 1h 1,5 h 2h
N/M N/M N/M N/M
870 1300 1300 870
Ni-Cd 6V 2,5Ah Ni-MH 6V 3,3Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah
6060
LED TECHNOLOGY EMERGENCY LUMINAIRES
Evolution Led ORDER CODE
SHORT CODE
CONSUMPTION * (W)
DURATION
ES08N10EBRD ES08N30EBRD ES11N10EBRD ES11N30EBRD ES18N10EBRD ES18N30EBRD ES24N10EBRD ES24N30EBRD ES08N10ABRD ES08N30ABRD ES11N10ABRD ES11N30ABRD ES18N10ABRD ES18N30ABRD ES24N10ABRD ES24N30ABRD ES08000IBS-D ES11000IBS-D ES18000IBS-D ES24000IBS-D
ES 1601 ES 1602 ES 1603 ES 1604 ES 1605 ES 1606 ES 1607 ES 1608 ES 1609 ES 1610 ES 1611 ES 1612 ES 1613 ES 1614 ES 1615 ES 1616 ES 1617 ES 1618 ES 1619 ES 1620
0,9 1,5 1,2 1,9 1,6 2,6 1,9 3,3 4,2 4 5,2 4,7 8,3 6,5 9,5 10,7 4 4,5 7,5 8,2
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
ES24N10EBRD-H ES24N10EBRD-HH ES24N13EBRD-HH ES24N20EBRD-H ES24000IBSD-H ES24000IBSD-HH
ES 1621 ES 1622 ES 1623 ES 1624 ES 1625 ES 1626
2,6 2,9 3,3 3,3 11 17
1h 1h 1,5 h 2h
ES08N10MBR ES08N30MBR ES11N10MBR ES11N30MBR ES18N10MBR ES18N30MBR ES24N10MBR ES24N30MBR
ES 1701 ES 1702 ES 1703 ES 1704 ES 1705 ES 1706 ES 1707 ES 1708
1,9 1,9 1,9 2,5 1,9 3,6 2,6 4,3
1h 3h 1h 3h 1h 3h 1h 3h
ES08000IBS ES11000IBS ES18000IBS ES24000IBS
ES 1901 ES 1902 ES 1903 ES 1904
3,1 3,5 6,1 6,8
ES24000IBS-H ES24000IBS-HH
ES 1905 ES 1906
8,5 12,8
ES08000IBS-SC ES11000IBS-SC ES18000IBS-SC ES24000IBS-SC
ES 2001 ES 2002 ES 2003 ES 2004
3,1 3,5 6,1 6,8
ES24000IBS-SC-H ES24000IBS-SC-HH
ES 2005 ES 2006
8,5 12,8
ES08000IBS-SC24 ES11000IBS-SC24 ES18000IBS-SC24 ES24000IBS-SC24
ES 2101 ES 2102 ES 2103 ES 2104
3,1 4,6 5,7 7,1
ES240IBS-SC24-H ES240IBS-SC24-HH
ES 2105 ES 2106
9,3 13,9
TYPE
AVERAGE FLUX N/M (lm)
N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M L L L L
185 180 205 185 415 295 680 680 185 180 205 185 415 295 680 680
FLUX M (lm)
BATTERY
DALI
185 180 205 185 415 295 680 680 195 215 430 700
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
DALI HIGH FLUX N/M N/M N/M N/M L L
870 1300 1300 870
MOVIE MOVIE MOVIE MOVIE MOVIE MOVIE MOVIE MOVIE
180 105 185 180 205 185 415 295
Ni-Cd 6V 2,5Ah Ni-MH 6V 3,3Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah 870 1300
MOVIE 15 15 15 15 15 15 15 15
Ni-Cd 6V 0,6Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah
CENTRAL BATTERY L L L L
195 215 430 700
CENTRAL BATTERY HIGH FLUX L L
870 1300
L L L L
195 215 430 700
SPY CENTER
SPY CENTER HIGH FLUX L L
870 1300
SPY CENTER 24 L L L L
235 320 430 630
SPY CENTER 24 HIGH FLUX L L
870 1300
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range can be powered also by a 110VDC relay and are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
61
TY
FIV
E YEA
R
Cristal Evo
TM
ARRAN
W
6262
LED TECHNOLOGY EMERGENCY LUMINAIRES
High flux up to 1300lm
CRISTAL EVO is the evolution of the Cristal series. The latest generation LED light source makes it ideal for even the most demanding environments such as department stores, industrial sheds and car parks
STYLISH AND ELEGANT DESIGN THIN AND SPACE-EFFICIENT PERFECTLY SUITED FOR OUTDOOR ENVIRONMENTS SUCH AS WAREHOUSES, INDUSTRIAL BUILDINGS, PARKING AREAS, ETC. HIGH LUMINOUS EFFICIENCY LED DECORATIVE FRAME SUPPLIED ON ALL INDIVIDUAL MODELS
C A
INSTALLATION: FLAG STYLE, CEILING AND RECESSED HIGH FLUX UP TO 1300 LUMEN B
MAXIMUM ENERGY SAVING THANKS TO THE LED TECHNOLOGY
IP65 A=380 mm B=180 mm C=58 mm
62
 documentation@linergy.it |
PACK
6
technical support 334 1133875
6262
LED TECHNOLOGY EMERGENCY LUMINAIRES
Cristal Evo Photometric diagrams Range Angles
Range Angles
Protection rating IP65 Available in versions with 10, 20 and 40 Led Installation on surfaces that are normally flammable Power supply: 230 Vac 50-60 Hz Available in versions with configurable rest mode and energy test
10 LED
20 LED
Range Angles
Range Angles
Compliant with European standards EN 60598-1, EN 60598-2-22 Photobiological hazard free according to standard EN 62471
40 LED
40 LED -HH codes
ACCESSORIES CR KT CGE Plasterboard and false ceiling fastening kit Kit for fixing the ceiling light on the plasterboard walls and false ceiling.
CR KT BLINDO Busway accessory Accessory that allows hook up to the busbar. CE KT SEG Signalling kit With this kit, CRISTAL EVO can be used as a signal luminaire in compliance with EN 1838. Kit of pictograms supplied as standard.
COMMANDER Controller for the remote management of rest mode Commander manages the rest status and carries out tests on the luminaire. On self-test models it allows for centralized control of the self-diagnosis functions.
SM KT SUP Kit for flag style fastening Bracket for fixing the ceiling light in flag style.
RACCORDO IP65 IP65 fitting supplied The IP65 fitting is supplied with the product to engage a 16 mm tube to the luminaire body.
KIT 45 GRADI With this bracket, the luminaire can be installed with an inclination of 45°
INC M CR Wall box for recessed installation Dimensions (mm): internal 365.6 x 167.1 max external 382.7 x 184.2 GRIG02 Protective grating Made in galvanized metal for complete protection of the luminaire body against accidental blows or acts of vandalism.
Pictograms: See the “Accessories and spare parts” section on page 154. Visual range with pictogram = 21 m.
CEIS01
CEIS02
ORDER CODE
SHORT CODE
DESCRIPTION
CEKTSEG CRKTBLINDO CRKTCGE GRIG02 INCMCR SMKTSUP KIT45GRADI CEIS01 CEIS02 CEIS08 CORNCR COMMANDER
A004 A005 A006 A013 A019 A047 A092 A146 A147 A148 A203 CN0001
SIGNALING KIT CRISTAL EVO BUSBAR KIT PLASTERBOARD AND DROPPED-CEILING FASTENING KIT PROTECTIVE GRATING WALL BOX RECESSED INSTALLATION CRISTAL KIT FOR FLAG-STYLE FASTENING CLASP FOR FIXING AT 45 DEGREES PICTOGRAM FOR CRISTAL EVO ARROW LEFT PICTOGRAM FOR CRISTAL EVO ARROW RIGHT PICTOGRAM FOR CRISTAL EVO ARROW DOWN AESTHETIC FRAME FOR CRISTAL CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
PACK 10 80 20 10 56 10 10 1 1 1 1 1
CEIS08
63
6464
LED TECHNOLOGY EMERGENCY LUMINAIRES
Cristal Evo EVEN EASIER TO ASSEMBLE The luminaire is equipped with a wall base which allows a 16 mm tube to enter from three sides or from the bottom. The reflector and glass cover become a single body and installation is a simple 2-step process. ELECTRIC CONNECTIONS
COMMANDER
COMMANDER
B
A
230~ SE
A
N/M models
SHORT CODE
CONSUMPTION * (W)
DURATION
CE08N10EGI CE08N30EGI CE11N10EGI CE11N30EGI CE24N10EGI CE24N30EGI
CE 1101 CE 1102 CE 1103 CE 1104 CE 1105 CE 1106
0,9 1,2 0,9 1,5 1,6 2,6
1h 3h 1h 3h 1h 3h
CE08N10AGR CE08N30AGR CE11N10AGR CE11N30AGR CE24N10AGR CE24N30AGR
CE 1201 CE 1202 CE 1203 CE 1204 CE 1205 CE 1206
4,2 4 8,3 6,5 9,5 10,7
1h 3h 1h 3h 1h 3h
CE08N10EGRT CE08N30EGRT CE11N10EGRT CE11N30EGRT CE24N10EGRT CE24N30EGRT CE08N10AGRT CE08N30AGRT CE11N10AGRT CE11N30AGRT CE24N10AGRT CE24N30AGRT
CE 1301 CE 1302 CE 1303 CE 1304 CE 1305 CE 1306 CE 1307 CE 1308 CE 1309 CE 1310 CE 1311 CE 1312
0,9 1,5 1,6 2,6 1,9 3,3 4,2 4 8,3 6,5 9,5 10,7
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
CE24N10EGRT-H CE24N10EGRT-HH CE24N20EGRT-HH CE24N30EGRT-H CE24N10AGRT-H
CE 1313 CE 1314 CE 1315 CE 1316 CE 1317
2,6 2,9 4,2 4,2 12,4
230~ SA
M models
TYPE
AVERAGE FLUX N/M (lm)
N/M N/M N/M N/M N/M N/M
160 110 200 160 450 290
M M M M M M
200 160 450 290 730 730
N/M N/M N/M N/M N/M N/M M M M M M M
200 160 450 290 730 730 200 160 450 290 730 730
FLUX M (lm)
BATTERY
INHIBIT Ni-Cd 6V 0,6Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah
REST MODE 200 160 450 290 730 730
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
200 160 450 290 730 730
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
1000
Ni-Cd 6V 2,5Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 5Ah Ni-Cd 6V 5Ah Ni-Cd 6V 2,5Ah
200 160 450 290 730 730
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
ENERGY TEST
ENERGY TEST HIGH FLUX 1h 1h 2h 3h 1h
N/M N/M N/M N/M M
1000 1300 1300 1000 1000
SPY SYSTEM CE08N10EGRC CE08N30EGRC CE11N10EGRC CE11N30EGRC CE24N10EGRC CE24N30EGRC CE08N10AGRC CE08N30AGRC CE11N10AGRC CE11N30AGRC CE24N10AGRC CE24N30AGRC
64
CE 1501 CE 1502 CE 1503 CE 1504 CE 1505 CE 1506 CE 1507 CE 1508 CE 1509 CE 1510 CE 1511 CE 1512
0,9 1,5 1,6 2,6 1,9 3,3 4,2 4 8,3 6,5 9,5 10,7
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
N/M N/M N/M N/M N/M N/M M M M M M M
200 160 450 290 730 730 200 160 450 290 730 730
230~ SE
4 5 6 1 2 3
4 5 6 1 2 3
ORDER CODE
B
6464
LED TECHNOLOGY EMERGENCY LUMINAIRES
Cristal Evo ORDER CODE
SHORT CODE
CONSUMPTION * (W)
CE24N10EGRC-H CE24N10EGRC-HH CE24N20EGRC-HH CE24N30EGRC-H CE24N10AGRC-H
CE 1513 CE 1514 CE 1515 CE 1516 CE 1517
2,6 2,9 4,2 4,2 12,4
DURATION
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
SPY SYSTEM HIGH FLUX 1h 1h 2h 3h 1h
N/M N/M N/M N/M M
1000 1300 1300 1000 1000
1000
Ni-Cd 6V 2,5Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 5Ah Ni-Cd 6V 5Ah Ni-Cd 6V 2,5Ah
200 160 450 290 730 730
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
1000
Ni-Cd 6V 2,5Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 5Ah Ni-Cd 6V 5Ah Ni-Cd 6V 2,5Ah
SPY SYSTEM WIRELESS CE08N10EGRW CE08N30EGRW CE11N10EGRW CE11N30EGRW CE24N10EGRW CE24N30EGRW CE08N10AGRW CE08N30AGRW CE11N10AGRW CE11N30AGRW CE24N10AGRW CE24N30AGRW
CE 2401 CE 2402 CE 2403 CE 2404 CE 2405 CE 2406 CE 2407 CE 2408 CE 2409 CE 2410 CE 2411 CE 2412
1,1 1,6 1,71 2,72 2 3,4 4,3 4,1 8,4 6,6 9,6 10,8
CE24N10EGRW-H CE24N10EGRW-HH CE24N20EGRW-HH CE24N30EGRW-H CE24N10AGRW-H
CE 2413 CE 2414 CE 2415 CE 2416 CE 2417
2,72 3 4,3 4,3 12,5
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
N/M N/M N/M N/M N/M N/M M M M M M M
200 160 450 290 730 730 200 160 450 290 730 730
SPY SYSTEM WIRELESS ALTO FLUSSO 1h 1h 2h 3h 1h
N/M N/M N/M N/M M
1000 1300 1300 1000 1000
N/M N/M N/M N/M N/M N/M M M M M M M L L L
200 160 450 290 730 730 200 160 450 290 730 730
DALI CE08N10EGRD CE08N30EGRD CE11N10EGRD CE11N30EGRD CE24N10EGRD CE24N30EGRD CE08N10AGRD CE08N30AGRD CE11N10AGRD CE11N30AGRD CE24N10AGRD CE24N30AGRD CE08000IGS-D CE11000IGS-D CE24000IGS-D
CE 1601 CE 1602 CE 1603 CE 1604 CE 1605 CE 1606 CE 1607 CE 1608 CE 1609 CE 1610 CE 1611 CE 1612 CE 1613 CE 1614 CE 1615
0,9 1,5 1,6 2,6 1,9 3,3 4,2 4 8,3 6,5 9,5 10,7 4 7,5 8,2
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
CE24N10EGRD-H CE24N10EGRD-HH CE24N20EGRD-HH CE24N30EGRD-H CE24N10AGRD-H CE24000IGS-D-H CE24000IGS-D-HH
CE 1616 CE 1617 CE 1618 CE 1619 CE 1620 CE 1621 CE 1622
2,6 2,9 4,2 4,2 12,4 11 17
1h 1h 2h 3h 1h
CE08000IGS CE11000IGS CE24000IGS
CE 1901 CE 1902 CE 1903
3,1 6,1 6,8
CE24000IGS-H CE24000IGS-HH
CE 1904 CE 1905
8,5 12,8
CE08000IGS-SC CE11000IGS-SC CE24000IGS-SC
CE 2001 CE 2002 CE 2003
3,1 6,1 6,8
CE24000IGS-SC-H CE24000IGS-SC-HH
CE 2004 CE 2005
8,5 12,8
CE08000IGS-SC24 CE11000IGS-SC24 CE24000IGS-SC24
CE 2101 CE 2102 CE 2103
3,1 5,7 7,1
CE240IGS-SC24-H CE240IGS-SC24-HH
CE 2104 CE 2105
9,3 13,9
200 160 450 290 730 730 215 470 690
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
DALI HIGH FLUX N/M N/M N/M N/M M L L
1000 1300 1300 1000 1000
1000 1000 1300
Ni-Cd 6V 2,5Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 5Ah Ni-Cd 6V 5Ah Ni-Cd 6V 2,5Ah
CENTRAL BATTERY L L L
215 470 690
CENTRAL BATTERY HIGH FLUX L L
1000 1300
L L L
215 470 690
SPY CENTER
SPY CENTER HIGH FLUX L L
1000 1300
SPY CENTER 24 L L L
300 540 650
SPY CENTER 24 HIGH FLUX L L
1000 1300
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range can be powered also by a 110VDC relay and are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
65
TY
FIV
E YEA
R
Cristal Wall
TM
ARRAN
W
6666
LED TECHNOLOGY EMERGENCY LUMINAIRES
Designed for wall mounted applications
CRISTAL WALL was designed exclusively for wall installations. Perfect for lighting exit routes, such as for large warehouses, industrial halls, car parks and outdoor safe places.
HIGH LUMINOUS EFFICIENCY LED DECORATIVE FRAME SUPPLIED ON ALL INDIVIDUAL MODELS C
INSTALLATION: WALL-MOUNTED
A
MAXIMUM ENERGY SAVING THANKS TO THE LATEST GENERATION LED TECHNOLOGY B
IP65 A=380 mm B=180 mm C=58 mm
66
 documentation@linergy.it |
PACK
6
technical support 334 1133875
6666
LED TECHNOLOGY EMERGENCY LUMINAIRES
Cristal Wall EVEN EASIER TO ASSEMBLE The luminaire is equipped with a wall base which allows a 16 mm tube to enter from three sides or from the bottom. The reflector and glass cover become a single body and installation is a simple 2-step process.
Photometric diagrams Range Angles
LIGHTING PERFORMANCE Range Angles
Individual installation (emergency exits, stairs, first aid areas, fire-fighting equipment, etc.)
10 lux
10 LED
20 LED
5 lux
Range Angles
1 lux
Maximum distance covered
40 LED
1 lux
14 m
5 lux
8.3 m
10 lux
6.7 m
Multiple installation (escape routes)
Protection rating IP65 Available in versions with 10, 20 and 40 Led
5 lux
Installation on surfaces that are normally flammable 1 lux
Power supply: 230 Vac 50-60 Hz Available in versions with configurable rest mode and energy test Compliant with European standards EN 60598-1, EN 60598-2-22 Photobiological hazard free according to standard EN 62471
Maximum spacing between fittings
Maximum distance covered
1 lux
12 m
26 m
5 lux
8m
16.3 m
10 lux
7m
14.2 m
Mounting height 2.5 m. Values calculated on floors without reflections with the CW24000IGS-HH device.
67
6868
LED TECHNOLOGY EMERGENCY LUMINAIRES
Cristal Wall ELECTRIC CONNECTIONS
ACCESSORIES CR KT CGE Plasterboard and false ceiling fastening kit Kit for fixing the ceiling light on the plasterboard walls.
COMMANDER
COMMANDER
230~ SE
B
A
A
B
230~ SA
230~ SE
COMMANDER Controller for the remote management of rest mode Commander manages the rest status and carries out tests on the luminaire. On self-test models it allows for centralized control of the self-diagnosis functions. RACCORDO IP65 IP65 fitting supplied The IP65 fitting is supplied with the product to engage a 16 mm tube to the luminaire body.
4 5 6 1 2 3
4 5 6 1 2 3
N/M models
INC M CR Wall box for recessed installation Dimensions (mm): internal 365.6 x 167.1 max external 382.7 x 184.2 GRIG02 Protective grating Made in galvanized metal for complete protection of the luminaire body against accidental blows or acts of vandalism.
ORDER CODE
SHORT CODE
CONSUMPTION * (W)
DURATION
CW08N10EGI CW08N30EGI CW11N10EGI CW11N30EGI CW24N10EGI CW24N30EGI
CW 1101 CW 1102 CW 1103 CW 1104 CW 1105 CW 1106
0,9 1,2 0,9 1,5 1,6 2,6
1h 3h 1h 3h 1h 3h
CW08N10AGR CW08N30AGR CW11N10AGR CW11N30AGR CW24N10AGR CW24N30AGR
CW 1201 CW 1202 CW 1203 CW 1204 CW 1205 CW 1206
4,2 4 8,3 6,5 9,5 10,7
1h 3h 1h 3h 1h 3h
CW08N10EGRT CW08N30EGRT CW11N10EGRT CW11N30EGRT CW24N10EGRT CW24N30EGRT CW08N10AGRT CW08N30AGRT CW11N10AGRT CW11N30AGRT CW24N10AGRT CW24N30AGRT
CW 1301 CW 1302 CW 1303 CW 1304 CW 1305 CW 1306 CW 1307 CW 1308 CW 1309 CW 1310 CW 1311 CW 1312
0,9 1,5 1,6 2,6 1,9 3,3 4,2 4 8,3 6,5 9,5 10,7
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
CW24N10EGRT-H CW24N10EGRT-HH CW24N20EGRT-HH CW24N30EGRT-H CW24N10AGRT-H
CW 1313 CW 1314 CW 1315 CW 1316 CW 1317
2,6 2,9 4,2 4,2 12,4
M models
ORDER CODE
SHORT CODE
DESCRIPTION
CRKTCGE GRIG02 INCMCR CORNCR COMMANDER
A006 A013 A019 A203 CN0001
PLASTERBOARD AND DROPPED-CEILING FASTENING KIT PROTECTIVE GRATING WALL BOX RECESSED INSTALLATION CRISTAL AESTHETIC FRAME FOR CRISTAL CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
TYPE
AVERAGE FLUX N/M (lm)
N/M N/M N/M N/M N/M N/M
180 110 225 180 415 280
M M M M M M
220 180 415 280 550 550
N/M N/M N/M N/M N/M N/M M M M M M M
220 180 415 280 550 550 220 180 415 280 550 550
PACK
FLUX M (lm)
BATTERY
INHIBIT Ni-Cd 6V 0,6Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah
REST MODE 220 180 415 280 550 550
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
220 180 415 280 550 550
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
700
Ni-Cd 6V 2,5Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 5Ah Ni-Cd 6V 5Ah Ni-Cd 6V 2,5Ah
220 180 415 280 550 550
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
ENERGY TEST
ENERGY TEST HIGH FLUX 1h 1h 2h 3h 1h
N/M N/M N/M N/M M
700 1000 1000 700 700
SPY SYSTEM CW08N10EGRC CW08N30EGRC CW11N10EGRC CW11N30EGRC CW24N10EGRC CW24N30EGRC CW08N10AGRC CW08N30AGRC CW11N10AGRC CW11N30AGRC CW24N10AGRC CW24N30AGRC
68
CW 1501 CW 1502 CW 1503 CW 1504 CW 1505 CW 1506 CW 1507 CW 1508 CW 1509 CW 1510 CW 1511 CW 1512
0,9 1,5 1,6 2,6 1,9 3,3 4,2 4 8,3 6,5 9,5 10,7
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
N/M N/M N/M N/M N/M N/M M M M M M M
220 180 415 280 550 550 220 180 415 280 550 550
20 10 56 1 1
6868
LED TECHNOLOGY EMERGENCY LUMINAIRES
Cristal Wall ORDER CODE
SHORT CODE
CONSUMPTION * (W)
CW24N10EGRC-H CW24N10EGRC-HH CW24N20EGRC-HH CW24N30EGRC-H CW24N10AGRC-H
CW 1513 CW 1514 CW 1515 CW 1516 CW 1517
2,6 2,9 4,2 4,2 12,4
DURATION
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
SPY SYSTEM HIGH FLUX 1h 1h 2h 3h 1h
N/M N/M N/M N/M M
700 1000 1000 700 700
700
Ni-Cd 6V 2,5Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 5Ah Ni-Cd 6V 5Ah Ni-Cd 6V 2,5Ah
220 180 415 280 550 550
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
700
Ni-Cd 6V 2,5Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 5Ah Ni-Cd 6V 5Ah Ni-Cd 6V 2,5Ah
SPY SYSTEM WIRELESS CW08N10EGRW CW08N30EGRW CW11N10EGRW CW11N30EGRW CW24N10EGRW CW24N30EGRW CW08N10AGRW CW08N30AGRW CW11N10AGRW CW11N30AGRW CW24N10AGRW CW24N30AGRW
CW 2401 CW 2402 CW 2403 CW 2404 CW 2405 CW 2406 CW 2407 CW 2408 CW 2409 CW 2410 CW 2411 CW 2412
1,1 1,6 1,71 2,72 2 3,4 4,3 4,1 8,4 6,6 9,6 10,8
CW24N10EGRW-H CW24N10EGRW-HH CW24N20EGRW-HH CW24N30EGRW-H CW24N10AGRW-H
CW 2413 CW 2414 CW 2415 CW 2416 CW 2417
2,72 3 4,3 4,3 12,5
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
N/M N/M N/M N/M N/M N/M M M M M M M
220 180 415 280 550 550 220 180 415 280 550 550
SPY SYSTEM WIRELESS HIGH FLUX 1h 1h 2h 3h 1h
N/M N/M N/M N/M M
700 1000 1000 700 700
N/M N/M N/M N/M N/M N/M M M M M M M L L L
220 180 415 280 550 550 220 180 415 280 550 550
DALI CW08N10EGRD CW08N30EGRD CW11N10EGRD CW11N30EGRD CW24N10EGRD CW24N30EGRD CW08N10AGRD CW08N30AGRD CW11N10AGRD CW11N30AGRD CW24N10AGRD CW24N30AGRD CW08000IGS-D CW11000IGS-D CW24000IGS-D
CW 1601 CW 1602 CW 1603 CW 1604 CW 1605 CW 1606 CW 1607 CW 1608 CW 1609 CW 1610 CW 1611 CW 1612 CW 1613 CW 1614 CW 1615
0,9 1,5 1,6 2,6 1,9 3,3 4,2 4 8,3 6,5 9,5 10,7 4 7,5 8,2
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
CW24N10EGRD-H CW24N10EGRD-HH CW24N20EGRD-HH CW24N30EGRD-H CW24N10AGRD-H CW24000IGS-D-H CW24000IGS-D-HH
CW 1616 CW 1617 CW 1618 CW 1619 CW 1620 CW 1621 CW 1622
2,6 2,9 4,2 4,2 12,4 11 17
1h 1h 2h 3h 1h
CW08000IGS CW11000IGS CW24000IGS
CW 1901 CW 1902 CW 1903
3,1 6,1 6,8
CW24000IGS-H CW24000IGS-HH
CW 1904 CW 1905
8,5 12,8
CW08000IGS-SC CW11000IGS-SC CW24000IGS-SC
CW 2001 CW 2002 CW 2003
3,1 6,1 6,8
CW24000IGS-SC-H CW24000IGS-SC-HH
CW 2004 CW 2005
8,5 12,8
CW08000IGS-SC24 CW11000IGS-SC24 CW24000IGS-SC24
CW 2101 CW 2102 CW 2103
3,1 5,7 7,1
CW240IGS-SC24-H CW240IGS-SC24-HH
CW 2104 CW 2105
9,3 13,9
220 180 415 280 550 550 170 380 550
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
DALI HIGH FLUX N/M N/M N/M N/M M L L
700 1000 1000 700 700
700 700 1000
Ni-Cd 6V 2,5Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 5Ah Ni-Cd 6V 5Ah Ni-Cd 6V 2,5Ah
CENTRAL BATTERY L L L
170 380 550
CENTRAL BATTERY HIGH FLUX L L
700 1000
L L L
170 380 550
SPY CENTER
SPY CENTER HIGH FLUX L L
700 1000
SPY CENTER 24 L L L
230 380 500
SPY CENTER 24 HIGH FLUX L L
700 1000
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range can be powered also by a 110VDC relay and are compatible with the Spy Center system, but they do not have control of the individual fixture. The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
69
TY
FIV
E YEA
R
Seven Glass
TM
ARRAN
W
7070
LED TECHNOLOGY EMERGENCY LUMINAIRES
Recessed on box 506
SEVEN GLASS has a sober and minimalist design. It has been created specifically to fit into the home with style and discretion. Recessed in standard electrical system six-contact block boxes, it is aesthetically finished with single-color plate supplied as standard.
PLATE WITH INTEGRATED DIFFUSER MINIMUM THICKNESS FOR A CLEAN AND PLEASANT APPEARANCE
C
EQUIPPED WITH 6 LATEST-GENERATION LEDS
D
A
IDEAL FOR SMALL ENVIRONMENTS F
B
USABLE IN PUBLIC ENTERTAINMENT VENUES AS STEP MARKER ON STAIRS
E A=206 mm B=80 mm C=52 mm D=4 mm E=138 mm F=40 mm
70
IP40  documentation@linergy.it |
PACK
12
technical support 334 1133875
7070
LED TECHNOLOGY EMERGENCY LUMINAIRES
Seven Glass
IP40 degree of protection Power Supply: 230 Vac 50-60 Hz Autonomy: 3h Recharge: 12h Lithium Phosphate Iron Battery: lasts twice as long as traditional Nickel Cadmium batteries. Complies with European standards EN 60598-1, EN 60598-2-22 No photobiological risk according to EN 62471
ORDER CODE
SHORT CODE
DESCRIPTION
COMMANDER
CN 0001
CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
PACK 1
Photometric diagram
QUICK AND EASY INSTALLATION
Range Angles
ORDER CODE
SHORT CODE
CONSUMPTION * (W)
DURATION
SB100N30EBR SB100N30ABR
SB 1201 SB 1202
0,8 0,8
3h 3h
SB100N30MBR
SB 1701
0,8
3h
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
60 60
60
Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 0,55Ah
60
12
Li-FePO4 3,2V 0,55Ah
REST MODE N/M M
MOVIE MOVIE
CENTRAL BATTERY SB100000IBS
SB 1901
0,8
L
60
SPY CENTER SB100000IBS-SC
SB 2001
0,8
L
60
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it. The SC MDL control module must be connected outside the fixture.
71
TY
FIV
E YEA
R
Seven Plus Led
TM
ARRAN
W
7272
LED TECHNOLOGY EMERGENCY LUMINAIRES
Recessed on box 506
SEVEN PLUS LED is a product featuring 6 x highluminosity LEDs. Because of its aesthetic beauty, it is especially suitable for residential applications. Recessed into the ordinary boxes of the 6-place box electrical system, it is aesthetically finished with plates of the most popular common ranges on the market.
C A
B
A=188 mm B=71 mm C=54 mm
COMPATIBLE WITH THE LATEST PLATES OF THE MOST COMMON CIVIL RANGE GREATER BRIGHTNESS FITTED WITH 6 LATEST GENERATION LEDS IDEAL FOR SMALL SETTINGS
ACCESSORIES SV PL55-N / SV PL55-M Kit IP55 The IP55 kit comprises the frame SVTL03, the diffuser, the grid and the seal. SVPL-B / SVPL-G White or grey colored finishing plate.
CAN BE USED IN PLACES OF PUBLIC EVENTS AS A MARKER ON THE STAIRS AND AS AN OUTDOOR LIGHT WITH RELEVANT IP55 PLATE
IP40  documentation@linergy.it |
72
PACK
12
technical support 334 1133875
7272
LED TECHNOLOGY EMERGENCY LUMINAIRES
Seven Plus Led Protection rating IP40 Power supply: 230 Vac 50-60 Hz Duration: 3h Recharge: 12h Lithium Iron Phosphate battery: lasts twice as long as traditional Nickel Cadmium batteries Compliant with European standards EN 60598-1, EN 60598-2-22 Photobiological hazard free according to standard EN 62471 ORDER CODE
SHORT CODE
DESCRIPTION
SVPL55-M SVPL55-N SVPL-B SVPL-G SVTL01 SVTL02 SVTL03 SVTL04 SVTL05 COMMANDER
A078 A067 A094 A079 A051 A052 A053 A054 A055 CN0001
KIT IP55 FINISH PLATE METALLIC SEVEN KIT IP55 FINISH PLATE BLACK SEVEN WHITE FINISH PLATE SEVEN CHARCOALGRAY FINISH PLATE SEVEN ADAPTING FRAMEWORKS - AVE, VIMAR PLATES ADAPTING FRAMEWORKS - BTICINO MASTER PLATES ADAPTING FRAMEWORKS - SEVEN ADAPTING FRAMEWORKS - SEVEN ADAPTING FRAMEWORKS - BTICINO LIVING AIR CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
Photometric diagram Range Angles
PACK 1 1 1 1 1 1 1 1 1 1
ADAPTER FRAMES Frames 01 and 02 are available on request.
Frames 03 and 04 are supplied as per standard.
Frame 01
VIMAR IDEA CLASSICA - IDEA RONDÒ PLANA - EIKON AVE NOIR - BANQUISE - ZAMA 45 - YES 45 - RAL 45 - SISTEMA 44
Frame 03
VIMAR EIKON - EIKON EVO - ARKÉ PLANA B-TICINO MATIX
Frame 02
B-TICINO AXOLUTE - LIVING CLASSIC LIVING INTERNATIONAL - LIGHT - LIGHT TECH - MATIX GEWISS CHORUS LUX - CHORUS ONE CHORUS GEO MASTER MODO + ACCESSORY FOR 7 MODULES
Frame 04
VIMAR IDEA B-TICINO AXOLUTE - LIVING LIGHT
Frame 05 must be ordered separately.
Patent pending
B-TICINO LIVING LIGHT AIR
Frame 05
ORDER CODE
SHORT CODE
CONSUMPTION * (W)
DURATION
SG100N30EBR SG100N30ABR
SG 1201 SG 1202
0,8 0,8
3h 3h
SG100N30MBR
SG 1701
0,8
3h
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
60 60
60
Li-FePO4 3,2V 0,55Ah Li-FePO4 3,2V 0,55Ah
60
12
Li-FePO4 3,2V 0,55Ah
REST MODE N/M M
MOVIE MOVIE
CENTRAL BATTERY SG100000IBS
SG 1901
0,8
L
60
SPY CENTER SG100000IBS-SC
SG 2001
0,8
L
60
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. The SC MDL control module must be connected outside the fixture.
73
7474
LED TECHNOLOGY EMERGENCY LUMINAIRES
Cometa
TM
Adapter frames available in white, black and grey COMETA is an extractable and portable emergency luminaire. Ideal for residential applications and available in versions with 2 and 3 modules and compatible with the main civil ranges.
EXTRACTABLE AND PORTABLE NI-MH RECHARGEABLE AND REPLACEABLE INSTALLED ON STANDARD 503 RECESS BOXES
F
A
G B
LIGHTING PERFORMANCE OF 2 HOURS
C
AVAILABLE IN A 2 AND 3 MODULES VERSION E
D
TORCH WITH SUPPORT --CLOSED TORCIA CON SUPPORTO CHIUSA
2 IN 1 OPERATION: N/M (NON-MAINTAINED) AND AS STEP MARKER
TORCHCON WITHSUPPORTO SUPPORT --APERTA OPEN TORCIA
A=44 mm B=42 mm C=44 mm D=48 mm E=57 mm F=71 mm G=49 mm
74
COMPATIBLE WITH THE MAIN COMMON RANGES ON THE MARKET
IP40  documentation@linergy.it |
PACK
40
technical support 334 1133875
7474
LED TECHNOLOGY EMERGENCY LUMINAIRES
Cometa Protection rating IP40 High-brightness LED Power supply: 230 Vac 50-60 Hz Guarantees 2 hours duration with 12h recharge Power supply terminals protected with extracted torch On/off key on the rear Alarm screw Blue marker light Red indicator for incorrect insertion Compliant with European standards EN 60598-1, EN 60598-2-22 2 MODULES PLATE WHITE
3 MODULES PLATE
GREY
BLACK
WHITE
GREY
BLACK
MARK AND MODEL PLATES BTICINO: MATIX
A 083
BTICINO: AXOLUTE AXOLUTE AIR
A 084
A 070
A 060
A 087
A 069
A 063
BTICINO: LIGHT - LIVING LIGHT - LIVING LIGHT AIR
A 085
A 071
A 061
A 088
A 073
A 064
VIMAR: EIKON - EIKON EVO PLANA - ARKÉ
A 086
A 072
A 062
A 089
A 074
A 065
GEWISS: CHORUS
A 091
A 076
A 066
A 090
A 075
A 059
A 082
PUSH & PULL SYSTEM EXTRACTION
1
2
3
6
7
4
REINSERTION
5
ORDER CODE
SHORT CODE
CM01N20ABI
CM 1101
CONSUMPTION * (W)
DURATION
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
INHIBIT 2h
M*
Ni-MH 3,6V 40mAh
* Circular blue Led stair light.
75
7676
LED TECHNOLOGY EMERGENCY LUMINAIRES
K-Led
K-LED is a single-module recessed LED emergency device, ideal for residential applications. Installed in standard electrical system boxes, it can operate in maintained or not maintained mode.
COMPATIBLE WITH THE MAIN CIVIL SERIES BY MEANS OF INCLUDED ADAPTERS RECESSED PRODUCT WITH “KEYSTONE” FASTENER ONE SPACE-SAVING MODULE ONLY
A
D
2 IN 1 OPERATION: N/M (NOT MAINTAINED) AND STEP MARKER CONSUMPTION < 1 W 2-HOUR LIGHT AUTONOMY
C
CHARGING TIME OF LESS THAN 3 HOURS NI-MH RECHARGEABLE AND REPLACEABLE BATTERY
B
COMPLIES WITH EUROPEAN STANDARDS EN 60598-1, EN 60598-2-22
IP20
PACK
16
A=22 mm B=44,5 mm C=46 mm D=46 mm documentation@linergy.it |
76
technical support 334 1133875
7676
LED TECHNOLOGY EMERGENCY LUMINAIRES
K Led
K-LED is extremely easy to install and can remain on for more than two hours.
ADAPTERS INCLUDED
VIMAR ARKÃ&#x2C6;
BTICINO LIVING LIGHT/INTERNATIONAL
VIMAR PLANA
BTICINO LIVING LIGHT
BTICINO
MATIX
ON: manual switch-on AUTO: automatic light switch-on in case of power failure ORDER CODE
SHORT CODE
KL01N20ABS
KL 1001
CONSUMPTION * (W)
DURATION
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
STANDARD 2h
M
Ni-MH 4,8V 80mAh
77
TY
FIV
ARRAN
Symmetrical and asymmetrical lens supplied as standard
metal body
VIALED EVO was created in particular to light exit routes and anti-panic areas, using a minimalist design that is not obtrusive from a visual point of view. It has an interchangeable symmetrical and asymmetrical lens and has high lighting performance.
A
D
C
E YEA
R
Vialed Evo
TM
W
7878
LED TECHNOLOGY EMERGENCY LUMINAIRES
B
HIGH-BRIGHTNESS LED STANDARD SYMMETRICAL AND ASYMMETRICAL OPTICS
E F G
PROTECTION RATING IP42 DURATION: 1h, 3h POWER SUPPLY: 230 VAC 50-60 Hz OPERATING TEMPERATURE: 0 °C - 40 °C RECESSED INSTALLATION IN THE CEILING
H I A=85 mm B=55 mm C=18 mm D=3,2 mm E=182 mm F=27 mm G=47 mm H=46 mm I=297 mm hole diameter 60=mm
MAXIMUM BATTERY RECHARGING TIME 12h COMPLIANT WITH EUROPEAN STANDARDS EN 60598-1, EN 60598-2-22
IP42 documentation@linergy.it |
78
PACK
8
technical support 334 1133875
7878
LED TECHNOLOGY EMERGENCY LUMINAIRES
Vialed Evo LIGHTING PERFORMANCE UP TO 3 m
Photometric diagrams Range Angles
Range Angles
18.5 m
ASYMMETRICAL - Individual installation Exit route illuminated with 1 lux - h 3 m ASYMMETRICAL
SYMMETRICAL 21 m
ACCESSORIES VLKTFS-B VLKTFS-G Box for ceiling installation available in white and grey (180 x 180 x 36 mm)
INTERRUTTORE
KIT INIBIZIONE OPZIONALE
J2
39.4 m
ASYMMETRICAL - Multiple installation Exit route illuminated with 1 lux - h 3 m
KIT MSINIB Kit consisting of wires and connector to make an external Inhibition line. Only for codes type M with Rest Mode and Energy Test.
AB LINEA INIBIZIONE
ORDER CODE
SHORT CODE
DESCRIPTION
KITMSINIB VLKTFS-G VLKTFS-B COMMANDER
A028 A080 A095 CN0001
INHIBITION KIT CLASP FOR CEILING FASTENING VIALED GREY CLASP FOR CEILING FASTENING VIALED WHITE CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
ORDER CODE
1 17 17 1
SHORT CONSUM.* DURAT. TYPE AVER. FL. FLUX BATTERY CODE (W) N/M (lm) M (lm)
11.7 m
11.7 m
PACK
SYMMETRICAL (surface covered 138 m2) Area illuminated with 0.5 lux - h 3 m
ORDER CODE
SHORT CONSUM.* DURAT. TYPE AVER. FL. FLUX BATTERY CODE (W) N/M (lm) M (lm)
WHITE
GREY
REST MODE
REST MODE
VE03N10EBR VE03N30EBR VE03F10ABR VE03F30ABR
VE 1201 VE 1202 VE 1203 VE 1204
0,8 0,8 5,3 5,3
1h 3h 1h 3h
VE03N10EBRT VE03N30EBRT VE03F10ABRT VE03F30ABRT
VE 1301 VE 1302 VE 1303 VE 1304
0,8 0,8 5,3 5,3
VE03N10EBRC VE03N30EBRC VE03F10ABRC VE03F30ABRC
VE 1501 VE 1502 VE 1503 VE 1504
0,8 0,8 5,3 5,3
VE03N10EBRW VE03N30EBRW VE03F10ABRW VE03F30ABRW
VE 2401 VE 2402 VE 2403 VE 2404
0,9 0,9 5,4 5,4
1h 3h 1h 3h
VE03N10EBRD VE03N30EBRD VE03000IBS-D
VE 1601 VE 1602 VE 1603
0,8 0,8 5,5
1h 3h
N/M N/M M M
300 200 300 300
300 300
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
VE03N10EGR VE03N30EGR VE03F10AGR VE03F30AGR
VE 1205 VE 1206 VE 1207 VE 1208
0,8 0,8 5,3 5,3
300 300
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
VE03N10EGRT VE03N30EGRT VE03F10AGRT VE03F30AGRT
VE 1305 VE 1306 VE 1307 VE 1308
0,8 0,8 5,3 5,3
300 300
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
VE03N10EGRC VE03N30EGRC VE03F10AGRC VE03F30AGRC
VE 1505 VE 1506 VE 1507 VE 1508
0,8 0,8 5,3 5,3
300 300
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
VE03N10EGRW VE03N30EGRW VE03F10AGRW VE03F30AGRW
VE 2405 VE 2406 VE 2407 VE 2408
0,9 0,9 5,4 5,4
1h 3h 1h 3h
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah
VE03N10EGRD VE03N30EGRD VE03000IGS-D
VE 1604 VE 1605 VE 1606
0,8 0,8 5,5
1h 3h
ENERGY TEST 1h 3h 1h 3h
N/M N/M M M N/M N/M M M N/M N/M M M
300 200 300 200
N/M N/M L
300 200 260
VE 2001
4,5
L
300
VE03000IGS
VE 1902
4,5
VE 2101
4,5
N/M N/M M M
300 200 300 300
300 300
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
1h 3h 1h 3h
N/M N/M M M
300 200 300 300
300 300
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
N/M N/M M M
300 200 300 200
300 300
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
N/M N/M L
300 200
L L
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah 260
L
300
SPY CENTER 300
VE03000IGS-SC
VE 2002
4,5
SPY CENTER 24 VE03000IBS-SC24
1h 3h 1h 3h
CENTRAL BATTERY
SPY CENTER VE03000IBS-SC
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
DALI
CENTRAL BATTERY 4,5
300 300
SPY SYSTEM WIRELESS
DALI
VE 1901
300 200 300 300
SPY SYSTEM 300 200 300 300
SPY SYSTEM WIRELESS
VE03000IBS
N/M N/M M M
ENERGY TEST 300 200 300 300
SPY SYSTEM 1h 3h 1h 3h
1h 3h 1h 3h
L
300
SPY CENTER 24 300
VE03000IGS-SC24
VE 2102
4,5
L
300
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it. The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39. VIALED EVO available on request with just symmetrical or asymmetrical lens.
79
TY
FIV
ARRAN
For large height with symmetrical and asymmetrical lens supplied as standard
metal body
VIALED HIGH is the high-performance Vialed, ideal for large height. It can be installed over 10 m in height.
A
D
C
R
Vialed High
E YEA
W
8080
LED TECHNOLOGY EMERGENCY LUMINAIRES
B
HIGH-BRIGHTNESS LED
E
STANDARD SYMMETRICAL AND ASYMMETRICAL OPTICS
F G
PROTECTION RATING IP42 DURATION 1h, 3h POWER SUPPLY: 230 VAC 50-60 Hz OPERATING TEMPERATURE: 0 °C - 40 °C
H I A=85 mm B=55 mm C=18 mm D=3,2 mm E=182 mm F=27 mm G=47 mm H=46 mm I=297 mm hole diameter 60=mm
RECESSED INSTALLATION IN THE CEILING MAXIMUM BATTERY RECHARGING TIME 12h COMPLIANT WITH EUROPEAN STANDARDS EN 60598-1, EN 60598-2-22
IP42 documentation@linergy.it |
80
PACK
8
technical support 334 1133875
8080
LED TECHNOLOGY EMERGENCY LUMINAIRES
Vialed High LIGHTING PERFORMANCE UP TO 10 m
Photometric diagrams Range Angles
Range Angles
19.7 m
ASYMMETRICAL - Individual installation Exit route illuminated with 1 lux - h 10 m ASYMMETRICAL
SYMMETRICAL 22.3 m
ACCESSORIES VLKTFS-B VLKTFS-G Box for ceiling installation available in white and grey (180 x 180 x 36 mm)
INTERRUTTORE
KIT INIBIZIONE OPZIONALE
J2
42 m
ASYMMETRICAL - Multiple installation Exit route illuminated with 1 lux - h 10 m
KIT MSINIB Kit consisting of wires and connector to make an external Inhibition line. Only for codes type M with Rest Mode and Energy Test.
AB LINEA INIBIZIONE
ORDER CODE
SHORT CODE
DESCRIPTION
KITMSINIB VLKTFS-G VLKTFS-B COMMANDER
A028 A080 A095 CN0001
INHIBITION KIT CLASP FOR CEILING FASTENING VIALED GREY CLASP FOR CEILING FASTENING VIALED WHITE CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
ORDER CODE
PACK 1 17 17 1
SHORT CONSUM.* DURAT. TYPE AVER. FL. FLUX BATTERY CODE (W) N/M (lm) M (lm)
9.8 m
9.8 m
SYMMETRICAL (surface covered 96 m2) Area illuminated with 0.5 lux - h 10 m
ORDER CODE
SHORT CONSUM.* DURAT. TYPE AVER. FL. FLUX BATTERY CODE (W) N/M (lm) M (lm)
WHITE
GREY
REST MODE
REST MODE
VH03N10EBR VH03N30EBR VH03F10ABR VH03F30ABR
VH 1201 VH 1202 VH 1203 VH 1204
0,8 0,8 5,3 5,3
1h 3h 1h 3h
VH03N10EBRT VH03N30EBRT VH03F10ABRT VH03F30ABRT
VH 1301 VH 1302 VH 1303 VH 1304
0,8 0,8 5,3 5,3
VH03N10EBRC VH03N30EBRC VH03F10ABRC VH03F30ABRC
VH 1501 VH 1502 VH 1503 VH 1504
0,8 0,8 5,3 5,3
VH03N10EBRW VH03N30EBRW VH03F10ABRW VH03F30ABRW
VH 2401 VH 2402 VH 2403 VH 2404
0,9 0,9 5,4 5,4
1h 3h 1h 3h
VH03N10EBRD VH03N30EBRD VH03000IBS-D
VH 1601 VH 1602 VH 1603
0,8 0,8 5,5
1h 3h
N/M N/M M M
300 200 300 300
300 300
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
VH03N10EGR VH03N30EGR VH03F10AGR VH03F30AGR
VH 1205 VH 1206 VH 1207 VH 1208
0,8 0,8 5,3 5,3
300 300
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
VH03N10EGRT VH03N30EGRT VH03F10AGRT VH03F30AGRT
VH 1305 VH 1306 VH 1307 VH 1308
0,8 0,8 5,3 5,3
300 300
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
VH03N10EGRC VH03N30EGRC VH03F10AGRC VH03F30AGRC
VH 1505 VH 1506 VH 1507 VH 1508
0,8 0,8 5,3 5,3
300 300
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
VH03N10EGRW VH03N30EGRW VH03F10AGRW VH03F30AGRW
VH 2405 VH 2406 VH 2407 VH 2408
0,9 0,9 5,4 5,4
1h 3h 1h 3h
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah
VH03N10EGRD VH03N30EGRD VH03000IGS-D
VH 1604 VH 1605 VH 1606
0,8 0,8 5,5
1h 3h
ENERGY TEST 1h 3h 1h 3h
N/M N/M M M N/M N/M M M N/M N/M M M
300 200 300 200
N/M N/M L
300 200 260
VH 2001
4,5
L
300
VH03000IGS
VH 1902
4,5
VH 2101
4,5
300 200 300 300
300 300
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
1h 3h 1h 3h
N/M N/M M M
300 200 300 300
300 300
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
N/M N/M M M
300 200 300 200
300 300
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
N/M N/M L
300 200
L L
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah 260
L
300
SPY CENTER 300
VH03000IGS-SC
VH 2002
4,5
SPY CENTER 24 VH03000IBS-SC24
N/M N/M M M
CENTRAL BATTERY
SPY CENTER VH03000IBS-SC
1h 3h 1h 3h
DALI
CENTRAL BATTERY 4,5
300 300
Ni-Cd 4,8V 1,4Ah Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
SPY SYSTEM WIRELESS
DALI
VH 1901
300 200 300 300
SPY SYSTEM 300 200 300 300
SPY SYSTEM WIRELESS
VH03000IBS
N/M N/M M M
ENERGY TEST 300 200 300 300
SPY SYSTEM 1h 3h 1h 3h
1h 3h 1h 3h
L
300
SPY CENTER 24 300
VH03000IGS-SC24
VH 2102
4,5
L
300
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it. The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39. VIALED HIGH available on request with just symmetrical or asymmetrical lens.
81
TY
FIV
R
Vialed Wall
E YEA
ARRAN
Patent pending
W
8282
LED TECHNOLOGY EMERGENCY LUMINAIRES
Symmetrical and asymmetrical lens supplied as standard VIALED WALL series is the wall-mounted Vialed that features an elegant design. It is equipped with a light source that can be positioned perpendicular to the floor or tilted 10°/20°.
aluminium build available in white
STANDARD SYMMETRICAL AND ASYMMETRICAL OPTICS IP20 PROTECTION RATING DURATION: 2h SUPPLY VOLTAGE: 230 VAC 50-60 HZ
C
OPERATING TEMPERATURE: 0 °C - 40 °C WALL MOUNTING
A
MAXIMUM BATTERY CHARGE TIME OF 12h COMPLIANT WITH EUROPEAN STANDARDS EN 60598-1, EN 60598-2-22 B
IP20 A=207 mm B=120 mm C=52 mm
82
documentation@linergy.it |
PACK
7
technical support 334 1133875
8282
LED TECHNOLOGY EMERGENCY LUMINAIRES
Vialed Wall LIGHTING PERFORMANCE
Photometric diagrams
ASYMMETRICAL - Individual installation (escape routes)
Range Angles
Range Angles
1 lux
ASYMMETRICAL 10°
SYMMETRICAL 10° Maximum distance covered: 15,4 m > 1 lx
ACCESSORIES TO BE ORDERED SEPARATELY INTERRUTTORE
KIT INIBIZIONE OPZIONALE
J2
KIT MSINIB Kit consisting of wires and connector to make an external Inhibition line. Only for codes type M with Rest Mode and Energy Test.
AB LINEA INIBIZIONE
ASYMMETRICAL - Multiple installation (escape routes)
LIGHTING SOURCE INCLINATION battery
1 lux
Maximum distance covered: 32,5 m > 1 lx
power unit
SYMMETRICAL - Individual installation (emergency exits, stairs, first aid areas, fire-fighting equipment, etc.)
20° 10° 0°
5 lux
light source
1 lux
ORDER CODE
SHORT CODE
DESCRIPTION
KITMSINIB COMMANDER
A028 CN0001
INHIBITION KIT CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
ORDER CODE
VW03N20EBR VW03F20ABR
PACK
SHORT CONSUM.* DURAT. TYPE AVER. FL. FLUX CODE (W) N/M (lm) M (lm)
VW 1201 VW 1203
0,8 5,3
1 1
BATTERY
Maximum distance covered: 10 m > 1 lx
Mounting height 2.5 m. Values calculated on floors without reflections with lighting source type device and 10° inclination.
ORDER CODE
SHORT CONSUM.* DURAT. TYPE AVER. FL. FLUX CODE (W) N/M (lm) M (lm)
WHITE
GREY
REST MODE
REST MODE
2h 2h
N/M M
300 300
Ni-MH 4,8V 2Ah 300
Li-FePO4 6,4V 1,5Ah
VW03N20EGR VW03F20AGR
VW 1202 VW 1204
0,8 5,3
ENERGY TEST VW03N20EBRT VW03F20ABRT
VW 1301 VW 1303
0,8 5,3
2h 2h
N/M M
VW 1501 VW 1503
0,8 5,3
2h 2h
N/M M
300 300
Ni-MH 4,8V 2Ah 300
Li-FePO4 6,4V 1,5Ah
VW03N20EGRT VW03F20AGRT
VW 1302 VW 1304
VW 2401 VW 2402
0,9 5,4
2h 2h
N/M M
0,8 5,3
300 300
Ni-MH 4,8V 2Ah 300
Li-FePO4 6,4V 1,5Ah
VW03N20EGRC VW03F20AGRC
VW 1502 VW 1504
0,8 5,3
VW 1601 VW 1602
0,8 5,5
VW03000IBS
VW 1901
4,5
2h
300 300
Ni-MH 4,8V 2Ah 300
Li-FePO4 6,4V 1,5Ah
VW03N20EGRW VW03F20AGRW
VW 2403 VW 2404
0,9 5,4
N/M L
300 265
Ni-MH 4,8V 2Ah
VW03N20EGRD VW03000IGS-D
VW 1603 VW 1604
0,8 5,5
L
300
VW03000IGS
VW 1902
4,5
4,5 4,5
2h 2h
300
300 300
300
N/M M
300 300
300
N/M L
300
N/M M
Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah
2h 2h
N/M M
Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah
2h 2h
Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah
L L
2h
Ni-MH 4,8V 2Ah 265
L
300
SPY CENTER 300
VW03000IGS-SC
VW 2002
4,5
SPY CENTER 24 VW03000IBS-SC24 VW 2101
300 300
Li-FePO4 6,4V 1,5Ah
CENTRAL BATTERY
SPY CENTER VW 2001
Ni-MH 4,8V 2Ah
DALI
CENTRAL BATTERY
VW03000IBS-SC
300
SPY SYSTEM WIRELESS
DALI VW03N20EBRD VW03000IBS-D
300 300
SPY SYSTEM
SPY SYSTEM WIRELESS VW03N20EBRW VW03F20ABRW
N/M M
ENERGY TEST
SPY SYSTEM VW03N20EBRC VW03F20ABRC
2h 2h
BATTERY
L
300
SPY CENTER 24 300
VW03000IGS-SC24 VW 2102
4,5
L
300
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. Luminous flux for symmetrical lens with 0° inclination. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
83
TY
FIV
R
Vialed Tube
E YEA
ARRAN
W
8484
LED TECHNOLOGY EMERGENCY LUMINAIRES
Symmetrical and asymmetrical lens supplied as standard aluminium build
VIALED TUBE is the evolution of the Vialed range. Perfect for installations that require special attention to aesthetics and design.
CEILING C
HIGH-EFFICIENCY LIGHTING LED
A
STANDARD SYMMETRICAL AND ASYMMETRICAL OPTICS
B
IP42 PROTECTION RATING DURATION: 2h SUPPLY VOLTAGE: 230 VAC 50-60 HZ SUSPENDED
OPERATING TEMPERATURE: 0 °C - 40 °C F
FITTING AND SUSPENSION INSTALLATION WITH ACCESSORY KIT H
D E
G
A=100 mm B=225 mm C=12 mm D=100 mm E=225 mm F=34 mm G=50 mm H=21 mm
84
MAXIMUM BATTERY CHARGE TIME OF 12h COMPLIANT WITH EUROPEAN STANDARDS EN 60598-1, EN 60598-2-22
IP42 documentation@linergy.it |
PACK
3
technical support 334 1133875
8484
LED TECHNOLOGY EMERGENCY LUMINAIRES
Vialed Tube ACCESSORI SOLD SEPARATELY ACCESSORY
Photometric diagrams STANDARD LENSES Range Angles
INTERRUTTORE
Range Angles
KIT INIBIZIONE OPZIONALE
J2 AB LINEA INIBIZIONE
ASYMMETRICAL
KIT MSINIB Kit consisting of wires and connector to make an external Inhibition line. Only for codes type M with Rest Mode and Energy Test.
SYMMETRICAL
LARGE HEIGHT LENSES Range Angles
Range Angles
Suspension (simulation of suspension type installation)
ASYMMETRICAL
ORDER CODE
SYMMETRICAL
SHORT CONSUM.* DURAT. TYPE AVER. FL. FLUX CODE (W) N/M (lm) M (lm)
BATTERY
ORDER CODE
SHORT CODE
DESCRIPTION
KITMSINIB VTKTSOS COMMANDER
A028 A058 CN0001
INHIBITION KIT KIT FOR SUSPENSION INSTALLATION VIALED TUBE CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
ORDER CODE
SHORT CONSUM.* DURAT. TYPE AVER. FL. FLUX CODE (W) N/M (lm) M (lm)
STANDARD LENSES VT 1201 VT 1202
0,8 5,3
2h 2h
N/M M
VT 1301 VT 1302
0,8 5,3
2h 2h
N/M M
Ni-MH 4,8V 2Ah 300
Li-FePO4 6,4V 1,5Ah
VU03N20EGR VU03F20AGR
VU 1201 VU 1202
0,8 5,3
VT 1501 VT 1502
0,8 5,3
2h 2h
N/M M
300 300
Ni-MH 4,8V 2Ah 300
Li-FePO4 6,4V 1,5Ah
VU03N20EGRT VU03F20AGRT
VU 1301 VU 1302
VT 2401 VT 2402
0,9 5,4
2h 2h
N/M M
0,8 5,3
300 300
Ni-MH 4,8V 2Ah 300
Li-FePO4 6,4V 1,5Ah
VU03N20EGRC VU03F20AGRC
VU 1501 VU 1502
0,8 5,3
VT 1601 VT 1602
0,8 5,5
VT03000IGS
VT 1901
4,5
2h
300 300
Ni-MH 4,8V 2Ah 300
Li-FePO4 6,4V 1,5Ah
VU03N20EGRW VU03F20AGRW
VU 2401 VU 2402
0,9 5,4
N/M L
300 265
Ni-MH 4,8V 2Ah
VU03N20EGRD VU03000IGS-D
VU 1601 VU 1602
0,8 5,5
L
300
VU03000IGS
VU 1901
4,5
4,5
VT 2101
4,5
300 300
300
300 300
300
N/M M
300 300
300
N/M L
300
Li-FePO4 6,4V 1,5Ah
2h 2h
N/M M
Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah
2h 2h
N/M M
Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah
2h 2h
Ni-MH 4,8V 2Ah Li-FePO4 6,4V 1,5Ah
L L
2h
Ni-MH 4,8V 2Ah 265
L
300
SPY CENTER 300
VU03000IGS-SC
VU 2001
4,5
SPY CENTER 24 VT03000IGS-SC24
Ni-MH 4,8V 2Ah
CENTRAL BATTERY
SPY CENTER VT 2001
300
DALI
CENTRAL BATTERY
VT03000IGS-SC
300 300
SPY SYSTEM WIRELESS
DALI VT03N20EGRD VT03000IGS-D
N/M M
SPY SYSTEM
SPY SYSTEM WIRELESS VT03N20EGRW VT03F20AGRW
2h 2h
ENERGY TEST
SPY SYSTEM VT03N20EGRC VT03F20AGRC
BATTERY
REST MODE 300 300
ENERGY TEST VT03N20EGRT VT03F20AGRT
1 1 1
LARGE HEIGHT LENSES
REST MODE VT03N20EGR VT03F20AGR
PACK
L
300
SPY CENTER 24 300
VU03000IGS-SC24
VU 2101
4,5
L
300
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it. The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
85
TY
FIV
R
Vialed Net
E YEA
ARRAN
W
8686
LED TECHNOLOGY EMERGENCY LUMINAIRES
1 Vialed Net kit can control 4 Vialed spotlights VIALED NET is a new power kit designed for the Vialed Evo, Vialed High, Vialed Wall and Vialed Tube series. Flexible and versatile, allows you to connect the spotlights in “star” or “cascade” through the terminal blocks on each spotlight.
recessed installation
D
A
C IP20 PROTECTION RATING B
DURATION: 2h
F E
SUPPLY VOLTAGE: 230 VAC 50-60 HZ OPERATING TEMPERATURE: 0 °C - 40 °C
G
INSTALLABLE INSIDE OF PT JUNCTION BOXES (starting from the PT 6 type)
I H
L A=85 mm B=60 mm C=45 mm D=3 mm E=182 mm F=46 mm G=27 mm H=135 mm I=27 mm L=54 mm Box sold separately. Installable inside of PT junction boxes (starting from the PT 6 type).
86
MAXIMUM BATTERY CHARGE TIME OF 12h COMPLIANT WITH EUROPEAN STANDARDS EN 60598-2-22, EN 61347-1
IP20 documentation@linergy.it |
PACK
1
technical support 334 1133875
8686
LED TECHNOLOGY EMERGENCY LUMINAIRES
Vialed Net CABLE CROSS-SECTIONS AND LENGTHS 0,75 mm
1,5 mm
2,5 mm
“STAR“ Connection
MAX distance of each light from central unit
40 m
80 m
140 m
“CASCADE“ Connection
MAX distance of light farther from central unit*
40 m
80 m
140 m
ORDER CODE
SHORT CODE
DESCRIPTION
VLKTFS-B VLKTFS-G COMMANDER
A095 A080 CN0001
CLASP FOR CEILING FASTENING VIALED WHITE CLASP FOR CEILING FASTENING VIALED GREY CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
PACK 17 17 1
* MAX distance between each light with “cascade” installation: 20 m
The kit to install in the junction boxes of the installation allows totally flexible connection of 4 Vialed devices.
“STAR” connection
“MIXED” connection
“CASCADE” connection
Box sold separately. Installable inside of PT junction boxes (starting from the PT 6 type).
HOW TO COMPOSE YOUR SYSTEM
VIALED EVO
VIALED NET
VIALED HIGH
CAN CONTROL 1 TO 4 VIALED
VIALED WALL VIALED TUBE
EXAMPLE OF SYSTEM LAYOUT:
VN04F20EBRT
+
VE03000IBS-N VH03000IGS-N VH03000IGS-N VW03000IBS-N
ORDER CODE
SHORT CODE
CONSUM. (W)
DURAT.
TYPE
LUMINOUS FLUX (lm)
BATTERY
VIALED EVO / WHITE VE03000IBS-N
VE 1801
4,5
L
300
L
300
VIALED EVO / GREY VE03000IGS-N
VE 1802
4,5
VIALED HIGH / WHITE ORDER CODE
SHORT CODE
DURAT.
TYPE
BATTERY
VH03000IBS-N
VH 1801
4,5
VIALED NET
VH03000IGS-N
VH 1802
4,5
REST MODE VN04F20EBR
VN 1201
2h
VN 1301
2h
N/M
Li-FePO4 12,8V 3Ah
VW03000IBS-N
VW 1801
VN 1501
2h
L
300
4,5
L
300
VIALED WALL / GREY N/M
Li-FePO4 12,8V 3Ah
VW03000IGS-N
VW 1802
SPY SYSTEM VN04F20EBRC
300
VIALED WALL / WHITE
ENERGY TEST VN04F20EBRT
L
VIALED HIGH / GREY
4,5
L
300
VIALED TUBE / STANDARD LENSES N/M
Li-FePO4 12,8V 3Ah
The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
VT03000IGS-N
VT 1801
4,5
L
300
VIALED TUBE / LARGE HEIGHT LENSES VU03000IGS-N
VU 1801
4,5
L
300
87
8888
LED TECHNOLOGY EMERGENCY LUMINAIRES
Nanoled
TM
The concealed emergency luminaire: simple, practical and efficient NANOLED is a simple Led emergency lighting fixture. Available in non-maintained version; it is maintenance-free. It is an ideal solution for residential settings.
AVAILABLE IN WHITE C
D
SYMMETRICAL LENS RECESSED INSTALLATION IN THE CEILING
A
B
PROTECTION RATING: IP40 FROM THE BOTTOM - IP20 FROM THE TOP
E
DURATION: 3h POWER SUPPLY: 230 VAC 50-60 Hz
G
OPERATING TEMPERATURE: 0 °C - 40 °C L
F
H I
A=43 mm B=31 mm C=25 mm D=2 mm E=205 mm F=132 mm G=30 mm H=30 mm I=210 mm L=31 mm
88
MAXIMUM BATTERY RECHARGING TIME 12h COMPLIANT WITH EUROPEAN STANDARDS EN 60598-1, EN 60598-2-22
IP20 IP40
documentation@linergy.it |
PACK
12
technical support 334 1133875
8888
LED TECHNOLOGY EMERGENCY LUMINAIRES
Nanoled INSTALLATION VERSATILITY It can be recessed in the false ceiling through a 35 mm diameter hole; the spotlight and the battery attach to each other via a quick coupling fitting. It is almost invisible in recharge stand-by conditions.
Photometric diagram Range Angles
SMALL AND BRIGHT Through the symmetrical optics, Nanoled emits a bright flux ideal for installation heights up to 6 m. It is the ideal solution for residential settings.
LIGHTING PERFORMANCE UP TO 3 m
EFFICIENT AND LONG-LASTING It guarantees duration of 3 h after recharge of 12 h. Duration of the Led is 50,000 operating hours. It operates at temperature from 0 °C to +40 °C.
7.3 m
7.3 m
Covered surface 54 m2 - Area illuminated with 0.5 lux - h 3 m
ORDER CODE
SHORT CODE
CONSUMPTION * (W)
DURATION
NL03N30EBS
NL 1001
1,1
3h
TYPE
AVERAGE FLUX N/M (lm)
N/M
130
FLUX M (lm)
BATTERY
STANDARD Ni-Cd 4,8V 1,8Ah
CENTRAL BATTERY NL03000IBS
NL 1901
2,3
L
130
L
130
SPY CENTER NL03000IBS-SC
NL 2001
2,3
SPY CENTER 24 NL03000IBS-SC24
NL 2101
1,5
L
130
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it.
89
9090
LED TECHNOLOGY EMERGENCY LUMINAIRES
Moon Led
TM
Movement sensor and adjustable dusk sensor Also available in white MOON LED is the ideal lamp for condominiums. The Led light source it features ensures practically unlimited switch-on and duration.
REFINED AESTHETICS
A
IT IS SUITABLE FOR ANY INDOOR AND OUTDOOR SETTING
B
CODE MB A=265 mm B=106 mm
AA
TYPE OF INSTALLATION: WALL AND CEILING MOTION AND TWILIGHT SENSORS SWITCH ON AUTOMATICALLY WHEN THEY DETECT TRANSIT, WHETHER IN DAYTIME OR AT NIGHT
BB
90
IDEAL FOR CONDOMINIUMS, LIGHTING OF STAIRS, SHOPS, HOMES
CODE ML A=335 mm B=119 mm
IP65
Ø26
documentation@linergy.it |
PACK
PACK
IK10
3
Ø33
2
technical support 334 1133875
9090
LED TECHNOLOGY EMERGENCY LUMINAIRES
Moon Led Type: M Maintained and non-maintained mode
ADJUSTABLE MOVEMENT SENSOR
Duration: 1 h - 3 h Installation on surfaces that are normally flammable Power supply 230 Vac 50-60 Hz Class of isolation: II
OFF
ON
Nominal Flux M: 1600 lm
ADJUSTABLE DUSK SENSOR
Protection rating IP65 Maximum recharging time: 12 h Colour temperature: 4000 K Compliant with European standards EN 60598-1, EN 60598-2-22 Photobiological hazard free according to standard EN 62471 Photometric diagram
OFF
ON
ONE POWER SUPPLY FOR ORDINARY AND EMERGENCY MODES The sensors inside the device will switch on the lamp as function of the ambient light and whether there are any people in the area. The product will always switch on in emergency backup even during power outages.
Range Angles
A single electronic board integrates:
1h/3h
DRIVER MOVEMENT/ DUSK SENSOR EMERGENCY
L N
230VAC ORDER CODE
SHORT CODE
Ø CONSUM.* DUR. TYPE AVER. FL. NOM. FL. BATTERY (cm) (W) N/M (lm) M (lm)
MB14F10ABR MB14F30ABR ML14F10ABR ML14F30ABR
MB 1201 MB 1202 ML 1201 ML 1202
26 26 33 33
14 14 14 14
MB14F10ABRT MB14F30ABRT ML14F10ABRT ML14F30ABRT
MB 1301 MB 1302 ML 1301 ML 1302
26 26 33 33
14 14 14 14
MB14F10ABRC MB14F30ABRC ML14F10ABRC ML14F30ABRC
MB 1501 MB 1502 ML 1501 ML 1502
26 26 33 33
14 14 14 14
MB14000IBS ML14000IBS
MB 1901 ML 1901
26 33
13,5 13,5
MB14000IBS-SC MB 2001 ML14000IBS-SC ML 2001
26 33
13,5 13,5
ORDER CODE
SHORT CODE
Ø CONSUM.* DUR. TYPE AVER. FL. NOM. FL. BATTERY (cm) (W) N/M (lm) M (lm)
WHITE
GREY
REST MODE
REST MODE
1h 3h 1h 3h
M M M M
320 320 320 320
1600 1600 1600 1600
Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 3Ah
MB14F10AGR MB14F30AGR ML14F10AGR ML14F30AGR
MB 1203 MB 1204 ML 1203 ML 1204
26 26 33 33
14 14 14 14
320 320 320 320
1600 1600 1600 1600
Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 3Ah
MB14F10AGRT MB14F30AGRT ML14F10AGRT ML14F30AGRT
MB 1303 MB 1304 ML 1303 ML 1304
26 26 33 33
14 14 14 14
320 320 320 320
1600 1600 1600 1600
Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
MB14F10AGRC MB14F30AGRC ML14F10AGRC ML14F30AGRC
MB 1503 MB 1504 ML 1503 ML 1504
26 26 33 33
14 14 14 14
1600 1600
MB14000IGS ML14000IGS
MB 1902 ML 1902
26 33
13,5 13,5
1600 1600
MB14000IGS-SC MB 2002 ML14000IGS-SC ML 2002
26 33
13,5 13,5
ENERGY TEST 1h 3h 1h 3h
M M M M M M M M
1600 1600 1600 1600
Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 3Ah
1h 3h 1h 3h
M M M M
320 320 320 320
1600 1600 1600 1600
Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 3Ah
1h 3h 1h 3h
M M M M
320 320 320 320
1600 1600 1600 1600
Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
CENTRAL BATTERY
SPY CENTER L L
320 320 320 320
SPY SYSTEM
CENTRAL BATTERY L L
M M M M
ENERGY TEST
SPY SYSTEM 1h 3h 1h 3h
1h 3h 1h 3h
L L
1600 1600
SPY CENTER L L
1600 1600
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
91
9292
LED TECHNOLOGY EMERGENCY LUMINAIRES
Vip Led
VIP LED was developed to meet the requirements of a product for industrial applications with zero maintenance and high energy savings. It is the ideal solution for large outdoor settings, industrial sheds, large warehouses, technical rooms, industries, garages, work places).
IDEAL FOR LARGE OUTDOOR SETTINGS (TECHNICAL ROOMS, INDUSTRIES, GARAGES, WAREHOUSES, WORK PLACES) ACCESSORIES FOR INSTALLATION PROVIDED INSIDE EVERY FIXTURE
D
B
CEILING INSTALLATION A
AVAILABLE IN VERSIONS: 15W, 42W, 56W C
92
Code
W
A
B
C
D
VD 15
15
675
95
145
330
VD 42
42
1285
95
145
800
VD 56
56
1585
95
145
860
PROTECTION RATING IP65
IP65
IK09
ï&#x20AC;&#x192; documentation@linergy.it |
PACK
1
technical support 334 1133875
9292
LED TECHNOLOGY EMERGENCY LUMINAIRES
Vip Led Installation on surfaces that are normally flammable Duration: 1 h - 3 h Power supply: 230 Vac 50-60 Hz Class of isolation: I Maximum recharging time: 12 h
Photometric diagrams Range Angles
Compliant with European standards EN 60598-1, EN 60598-2-22
Range Angles
15 W
Photobiological hazard free according to standard EN 62471
ORDER CODE
SHORT CODE
CONSUMPTION * (W)
DURATION
VD15F10EGR VD15F30EGR VD42F10EGR VD42F30EGR VD56F10EGR VD56F30EGR VD15F10AGR VD15F30AGR VD42F10AGR VD42F30AGR VD56F10AGR VD56F30AGR
VD 1201 VD 1202 VD 1203 VD 1204 VD 1205 VD 1206 VD 1207 VD 1208 VD 1209 VD 1210 VD 1211 VD 1212
16 16 43 43 57 57 16 16 43 43 57 57
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
VD15F10EGRT VD15F30EGRT VD42F10EGRT VD42F30EGRT VD56F10EGRT VD56F30EGRT VD15F10AGRT VD15F30AGRT VD42F10AGRT VD42F30AGRT VD56F10AGRT VD56F30AGRT
VD 1301 VD 1302 VD 1303 VD 1304 VD 1305 VD 1306 VD 1307 VD 1308 VD 1309 VD 1310 VD 1311 VD 1312
16 16 43 43 57 57 16 16 43 43 57 57
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
VD15F10EGRC VD15F30EGRC VD42F10EGRC VD42F30EGRC VD56F10EGRC VD56F30EGRC VD15F10AGRC VD15F30AGRC VD42F10AGRC VD42F30AGRC VD56F10AGRC VD56F30AGRC
VD 1501 VD 1502 VD 1503 VD 1504 VD 1505 VD 1506 VD 1507 VD 1508 VD 1509 VD 1510 VD 1511 VD 1512
16 16 43 43 57 57 16 16 43 43 57 57
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
VD15000IGS-D VD42000IGS-D VD56000IGS-D
VD 1601 VD 1602 VD 1603
15 42 56
VD15000IGS VD42000IGS VD56000IGS
VD 1901 VD 1902 VD 1903
15 42 56
VD15000IGS-SC VD42000IGS-SC VD56000IGS-SC
VD 2001 VD 2002 VD 2003
15 42 56
Range Angles
42 W
TYPE
AVERAGE FLUX N/M (lm)
56 W
NOMINAL FLUX M (lm)
BATTERY
REST MODE N/M N/M N/M N/M N/M N/M M M M M M M
390 390 420 420 420 420 390 390 420 420 420 420
1914 1914 5742 5742 7656 7656
Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
1914 1914 5742 5742 7656 7656
Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
1914 1914 5742 5742 7656 7656
Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
ENERGY TEST N/M N/M N/M N/M N/M N/M M M M M M M
390 390 420 420 420 420 390 390 420 420 420 420
SPY SYSTEM N/M N/M N/M N/M N/M N/M M M M M M M
390 390 420 420 420 420 390 390 420 420 420 420
DALI L L L
1914 5742 7656
CENTRAL BATTERY L L L
1914 5742 7656
L L L
1914 5742 7656
SPY CENTER
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
93
9494
LED TECHNOLOGY EMERGENCY LUMINAIRES
Ice
THE ELECTRONIC HEAT ADJUSTMENT OF THE BATTERY ALLOWS INSTALLATION AT -30 °C
ceiling
wall
Automatic dusk sensor A
ICE is a luminaire particularly suitable environments with temperatures to -30 °C.
for
C
LED MAINTAINED FIXTURE ENTIRELY IN SHOCK-PROOF POLYCARBONATE B
THE BATTERIES ARE RECHARGED AT LOW TEMPERATURE IN CASE OF A BLACKOUT EMERGENCY OPERATION IS ENSURED UP TO -30°C A TWO-COLOUR LED INDICATES THE STATUS: GREEN: OK RED: MALFUNCTIONING
E
D F
A=265 mm B=92 mm C=125 mm D=99 mm E=148 mm F=70°
IP65 documentation@linergy.it |
94
IK10
PACK
1
technical support 334 1133875
9494
MODELLO NON PERMANENTE MODELLO NON PERMANENTE IC05N30EBST-M & IC05N30EBST-P IC05N30EBST-M & IC05N30EBST-P
3 Hr3 Hr L E D T E C H N OL2L O L1GNY E M E R G E N C Y L U M I N A I R E S
80lm 80lm
L2 L1 N X X L N
Light source: 5 x 1W LED
Ice
X X L N
ACCESSORIES ACCESSORI
Lamp color temperature: 4000 K
MODELLO PERMANENTE CON DISPOSITIVO CREPUSCOLARE MODELLO PERMANENTE DISPOSITIVO CREPUSCOLARE IC05N30ABST-M & CON IC05N30ABST-P IC KT SEG-M IC05N30ABST-M & IC05N30ABST-P
Power supply: 230 Vac 50-60 Hz
Kit for flag style installation for fixing to wall
Self-diagnosis device Test button to verify correct operation in emergency mode
L2 L1 N
IC KT SEG-P Kit for flag style installation 100lm for fixing to ceiling 100lm
L N L N
Kit with pictograms for all the signs
Installable environment temperature: -30 ºC / +40 ºC L2 L1 N Luminaire body: Polycarbonate Glass: Transparent polycarbonate Compliant with European standards EN 60598-1, EN 60598-2-22 Photobiological hazard free according to standard EN 62471 The ICE luminaire has two lighting levels M:
L2 L1 N SHORT L2ORDER L1 CODE N CODE ICKTSEG-M ICKTSEG-P
HIGH BRIGHTNESS
Supplied as standard in IN every box DI LUCE, LA LAMPADA ICE ASSENZA (rh, lh, straight on) ACCENDE I LED IN MODALITA’ PERMANEN
A017 A018
IN ASSENZA DI LUCE, LA LAMPADA ICE TRAMITE L’INTERRUTTORE ACCENDE I LED IN MODALITA’CREPUSCOLA PERMANENT TRAMITE L’INTERRUTTORE CREPUSCOLAR
500lm DESCRIPTION
PACK
500lm
SIGNALING KIT ICE WALL SIGNALING KIT ICE CEILING
1 1
L N
L N
LOW BRIGHTNESS Photometric diagrams Range Angles
N/M ENERGY TEST3MODELS Hr L2 L1 N 80 lm 3 Hr
Range Angles
L2 L1 N
IN ASSENZA DI 230VAC, LA LAMPADA ICE ACCENDE I LED IN MODALITA’ NON PERMANENTE
80 lm
X X
X X
IN ASSENZA DI 230VAC, LA LAMPADA ICE ACCENDE I LED IN MODALITA’ NON PERMANENT
*N.B. Il dispositivo crepuscolare è possibile disa escludendo il fotodiodo, in questo caso la moda PERMANENTE non sarà disattivabile. *N.B. Il dispositivo crepuscolare è possibile disatt escludendo il fotodiodo, in questo caso la modali PERMANENTE non sarà disattivabile.
L N
L N
MODELLO CENTRAL BATTERY CON DISPOSITIVO CREPUSCOLARE IC05000IBS-M & IC05000IBS-P
M ENERGY TEST MODEL AND CENTRAL BATTERY
WALL
MODELLO CENTRAL BATTERY CON DISPOSITIVO CREPUSCOLARE IC05000IBS-M & IC05000IBS-P
CEILING
L2 L1 N
L2 L1 N 80 lm
CORRIDOR LIGHTING
425 lm
L2 L1 N
L2 L1 N L N
80 lm
425 lm
L N
L N
L N If there is no light, the Ice luminaire switches on in maintained mode via the dusk sensor switch.
IN ASSENZA DI LUCE ACCENDE I LED IN MO TRAMITE L’INTERRUT IN ASSENZA DI LUCE, L ACCENDE I LED IN MOD TRAMITE L’INTERRUTTO
*N.B. Il dispositivo cr escludendo il fotodio si accender’ soltanto
*N.B. Il dispositivo crep escludendo il fotodiod si accender’ soltanto se
*N.B. the dusk sensor device can be deactivated by excluding the photodiode. In this case, the luminaire will only switch on if there is 230Vac present.
ORDER CODE
SHORT CONSUM.* DURAT. TYPE AVER. FL. FLUX CODE (W) N/M (lm) M (lm)
BATTERY
ORDER CODE
SHORT CONSUM.* DURAT. TYPE AVER. FL. FLUX CODE (W) N/M (lm) M (lm)
WALL INSTALLATION
CEILING INSTALLATION
ENERGY TEST IC05N30EBST-M IC05N30ABST-M
IC 1301 IC 1302
4 9
IC05000IBS-M
IC 1901
7
3h 3h
N/M M
ENERGY TEST 80 80
425
Ni-Cd 3,6V 1,6Ah Ni-Cd 3,6V 1,6Ah
IC05N30EBST-P IC05N30ABST-P
IC 1303 IC 1304
4 9
IC05000IBS-P
IC 1902
7
CENTRAL BATTERY L
IC 2001
7
L L
N/M M
80 80
425
Ni-Cd 3,6V 1,6Ah Ni-Cd 3,6V 1,6Ah
L
425
SPY CENTER 425
IC05000IBS-SC-P
IC 2002
SPY CENTER 24 IC0500IBS-SC24-M IC 2101
3h 3h
CENTRAL BATTERY 425
SPY CENTER IC05000IBS-SC-M
BATTERY
7
L
425
SPY CENTER 24 425
IC0500IBS-SC24-P
IC 2102
L
425
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it.
95
9696
LED TECHNOLOGY EMERGENCY LUMINAIRES
Icetek
TM THE ELECTRONIC HEAT ADJUSTMENT OF THE BATTERY ALLOWS INSTALLATION AT -40 °C
Luminous flux up to 1300lm ICETEK is an emergency luminaire specially designed to work in cold environments with temperatures up to -40 °C. Thanks to Linergy technology, the lamp components guarantee proper operation even at very low temperatures.
PROTECTION RATING IP67: FIXTURE TOTALLY PROTECTED AGAINST DUST AND WATER THE BATTERIES ARE RECHARGED AT LOW TEMPERATURE IN CASE OF A BLACKOUT EMERGENCY OPERATION IS ENSURED UP TO -40°C
C A
B
A TWO-COLOUR LED INDICATES THE STATUS: GREEN: OK RED: MALFUNCTIONING
IP67
PACK
6
A=420 mm B=168 mm C=82 mm documentation@linergy.it |
96
technical support 334 1133875
9696
LED TECHNOLOGY EMERGENCY LUMINAIRES
Icetek Light source: 40 LED
ACCESSORIES ACCESSORI
Power supply: 230 Vac 50-60 Hz
COMMANDER Controller for the remote management of rest mode Commander manages the rest status and carries out tests on the luminaire. On self-test models it allows for centralized control of the self-diagnosis functions.
Class of isolation: II (double isolation) Self-diagnostic device Protection rating IP67
IP67 CABLE GLAND Comes standard with the product. Allows you to connect the device to the electric cable ensuring the tightness of the IP67 protection rating.
Installable with a room temperature of: -40 ºC / +40 ºC Glass: Transparent polycarbonate Battery: Ni-Mh 6V / 4Ah
GRIG02 Protective grating Made in galvanized metal for complete protection of the luminaire body against accidental blows or acts of vandalism.
Standard duration: 1 h IP67 cable gland included Compliant with European standards EN 60598-1, EN 60598-2-22 Photobiological hazard free according to standard EN 62471
Pictograms: See the “Accessories and spare parts” section on page 154. Visual range with pictogram = 26 m.
Photometric diagram Range Angles
TKIS01
ORDER CODE
SHORT CODE
CONSUMPTION * (W)
IT24N10EGRT-H IT24N10EGRT-HH IT24N10AGRT-H
IT 1301 IT 1302 IT 1303
4,5 6 14
DURATION
TKIS02
TKIS08
ORDER CODE
SHORT CODE
DESCRIPTION
GRIG02 COMMANDER TKIS01 TKIS02 TKIS08
A013 CN0001 A180 A181 A182
PROTECTIVE GRATING CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE PICTOGRAMS FOR ICETEK - LEFT PICTOGRAMS FOR ICETEK - RIGHT PICTOGRAMS FOR ICETEK - DOWN
TYPE
AVERAGE FLUX N/M (lm)
PACK
FLUX M (lm)
10 1 1 1 1
BATTERY
ENERGY TEST HIGH FLUX 1h 1h 1h
N/M N/M M
900 1300 900
1000
Ni-MH 6V 4Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah
1000
Ni-MH 6V 4Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah
1000
Ni-MH 6V 4Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah
SPY SYSTEM HIGH FLUX IT24N10EGRC-H IT24N10EGRC-HH IT24N10AGRC-H
IT 1501 IT 1502 IT 1503
4,5 6 14
1h 1h 1h
N/M N/M M
900 1300 900
SPY SYSTEM WIRELESS HIGH FLUX IT24N10EGRW-H IT24N10EGRW-HH IT24N10AGRW-H
IT 2401 IT 2402 IT 2403
4,6 6,1 14,1
1h 1h 1h
N/M N/M M
900 1300 900
CENTRAL BATTERY HIGH FLUX IT24000IGS-H IT24000IGS-HH
IT 1901 IT 1902
8,5 12,8
IT24000IGS-SC-H IT24000IGS-SC-HH
IT 2001 IT 2002
8,5 12,8
IT240IGS-SC24-H IT240IGS-SC24-HH
IT 2101 IT 2102
9,3 13,9
L L
1000 1300
SPY CENTER HIGH FLUX L L
1000 1300
SPY CENTER 24 HIGH FLUX L L
825 1300
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
97
9898
LED TECHNOLOGY EMERGENCY LUMINAIRES
Atex Led
ATEX LED is an explosion-proof emergency luminaire for explosion-prone workplaces. It is designed for use in industrial areas or structures and can be used in both indoor and outdoor areas. It is a product suitable for zones 1,2 and 21,22.
Energy Test function with TEST BUTTON Maintained (M) type with Not Maintained (N/M) operation option Operating temperature from -20°C to +50°C
A
Corrosion-resistant polyurethane powder-coated aluminum end caps
B C
Borosilicate glass diffuser Silicone rubber seals Installation: suspension, wall and ceiling Complies with ATEX Directive 94/9/EC Conforms to European standards: EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-31, EN 60598-1, EN 60598-2-22, EN 62034, EN 62031, EN 62471
D E
G
F
Ex II 2 G - Ex d IIC T6 Gb from -20°C to +50°C Ex II 2 G - Ex de IIC T6 Gb from -20°C to +50°C
PACK
1
Ex II 2 D - Ex tb IIIC T80°C Db IP66 from -20°C to +50°C
A=330mm B=240mm C=12mm D=220mm E=160mm F=180mm G=Ø13mm ORDER CODE
SHORT CODE
DURAT. TYPE
AVER. FL. N/M (lm)
FLUX M (lm)
BATTERY
ENERGY TEST AX20N30AGRT
98
AX 1301
3h
M
200
200
Ni-MH 3,6V 2Ah
IP66 documentazione@linergy.it |
IK08
PACK
1
technical support 334 1133875
9898
HALOGEN EMERGENCY LUMINAIRES
Dual Led
The DUAL LED series of lamps are designed to light large spaces and can also be installed at great heights. Fixed or portable, they feature high-efficiency Led bulbs inside of adjustable spotlights.
Type: N/M – Non-Maintained Duration: 1 h 30’ / 3 h Installation: on surfaces that are normally flammable Class of isolation: II Protection rating: IP 65 Fixture supplied with 12 high performance Led Operating temperature: 0÷40 °C Recharging time: 24 h
B
C
Compliant with European standards EN 60598-1, EN 60598-2-22, EN 60598-2-8 Photobiological hazard free according to standard EN 62471
A
IP65 D
PACK
1
ORDER CODE
SHORT CODE
DURAT.
DU239P13EGS DU239P30EGS
DU 1001 DU 1002
1,5 h 3h
DU237P30EGST
DU 1301
TYPE
AVER. FLUX N/M (lm)
BATTERY
STANDARD
A = 333 mm B = 307 mm C = 95 mm D = 205 mm
N/M N/M
2000 2000
Pb 12V 7Ah 2 x Pb 12V 7Ah
2000
2 x Pb 12V 7Ah
ENERGY TEST 3h
N/M
99
100100
HALOGEN EMERGENCY LUMINAIRES
Send an e-mail to documentation@linergy.it and you will receive a link to download the constantly updated technical-sales material. NOTE Specify in object: “Documentation”
100
100100
HALOGEN EMERGENCY LUMINAIRES
Dual
2x20W
2x55W
The DUAL series of lamps are designed to light large spaces and can also be installed at great heights. Fixed or portable, they feature highefficiency halogen bulbs inside of adjustable spotlights.
Type: N/M – Non-Maintained B
Duration: 1 h - 1 h 30’
C
Installation: on surfaces that are normally flammable Class of isolation: II A
Protection rating: IP 65
D
N/M average flux 2x20W: 580 lm - 2x55W: 2050 lm Recharging time: 24 h
A = 330 mm B = 300 mm C = 95 mm D = 205 mm
B
Possibility of emergency inhibition with remote control Compliant with European standards EN 60598-1, EN 60598-2-22, EN 60598-2-8
C
PACK
IP65
A D
1
ORDER CODE
SHORT CODE
LAMP
DL220P13EGS DL255P10EGS
DL 1001 DL 1002
2x20W 2x55W
DL220P13EGR DL255P10EGR
DL 1201 DL 1202
2x20W 2x55W
DURAT. TYPE AVER. FL. FLUX N/M (lm) M (lm)
BATTERY
STANDARD
A = 395 mm B = 305 mm C = 95 mm D = 210 mm
1,5 h 1h
N/M N/M
580 2050
Pb 12V 7Ah 2 x Pb 12V 9Ah
580 2050
Pb 12V 7Ah 2 x Pb 12V 9Ah
REST MODE 1,5 h 1h
N/M N/M
101
102102
LED TECHNOLOGY SIGNALLING LUMINAIRES
Send an e-mail to documentation@linergy.it and you will receive a link to download the constantly updated technical-sales material. NOTE Specify in object: “Documentation”
102102
LED TECHNOLOGY SIGNALLING LUMINAIRES
WHAT ARE THEY? The signalling luminaires are essential for guaranteeing the correct identification of escape routes, as required by the regulations in force and in particular EN 1838. The signs must be visible in all points of the escape route and must indicate it without any possibility of error. HOW TO CHOOSE THEM Choosing the right signal luminaire requires knowledge of the various typologies and functionality of the same and the basic features. SIGN VISIBILITY A fundamental parameter is the size of the sign, which affects the visual range. EN 1838 establishes the maximum visual range of the sign in relation to its height according to the following formula: L=zxh L is the maximum visual range of the signal h is the height of the pictogram z is respectively: 100 for signs that are externally lit 200 for signs that are internally lit Therefore, in addition to the size, it is important to pay attention to the light source of the sign itself, i.e. check to see whether it is lit from the inside, like a ceiling light equipped with a pictogram, or from the outside.
INHIBITION AND REST MODE Whenever long periods of plant inactivity are foreseen, it is appropriate to choose ceiling lights that come with this function. Having the â&#x20AC;&#x153;Rest modeâ&#x20AC;? function can be important when it is necessary to inhibit the functioning of the signalling system. Using the special remote control device, the rest-mode status can be managed and the inhibition of the luminaires is guaranteed,while still keeping them active and self-restorable in the event of a blackout. DURATION The luminaire duration required by regulations prescribes 1 or 3 hours; in some cases even 2, depending on the various settings. As the batteries discharge over time, the real duration of the new luminaire will always be greater compared to the nominal declared. When, as a result of natural deterioration of the batteries, nominal duration is no longer ensured, these batteries should be replaced. RECHARGE The battery recharge time after switch-on of a luminaire during an emergency must guarantee the nominal duration of the luminaire itself. Normally, the regulations establish a recharging time of 24 hours. Only in certain settings are fixtures with a 12-hour recharging time mandatory.
h L
FUNCTIONING TYPE Normally, M type luminaires or maintained luminaires are used, because the sign must be lit constantly, with or without the presence of a network. L models are also used, powered from a centralized energy station.
103
TY
FIV
E YEA
R
Orion
TM
ARRAN
W
104104
LED TECHNOLOGY SIGNALLING LUMINAIRES
ORION is a signal luminaire with a linear and minimalist design, characterised by its metal body and great reliability.
DIE-CAST ALUMINIUM BODY 14 LED FOR GREATER BRIGHTNESS TEST BUTTON INSTALLABLE WITH SINGLE OR DOUBLE SIDES WITH PICTOGRAM KIT SUPPLIED AS STANDARD
also with white body
INSTALLATION: WALL, CEILING, FLAG STYLE, SUSPENSION
A
KEY FOR SETTING THE LEVEL OF BRIGHTNESS IN THE PRESENCE OF A NETWORK, FOR USE IN CINEMAS AND THEATRES
C
D
5
B E
F
A=315 mm B=269 mm C=39 mm D=85 mm E=184 mm F=280 mm
4
ENERGY CONSUMPTION METHOD OF USE
CONSUMPTION
ORION MAINTAINED
3W
ORION MOVIE - BRIGHTNESS REDUCED BY PUSH BUTTON
1W
ORION NON-MAINTAINED
0.8 W
ï&#x20AC;&#x192; documentation@linergy.it |
104
PACK
IP40
technical support 334 1133875
104104
LED TECHNOLOGY SIGNALLING LUMINAIRES
Orion SINGLE BRACKET
STANDARD ACCESSORIACCESSORIES OR KT STAFFA-G / -B Bracket for flag style fastening
OR KT STAFFA-G / -B Bracket for wall fastening
Bracket/cover for ceiling fastening
Wall-mounted
Flag style
High-brightness, white led light source
Wall fastening bracket for reverse installation
High-brightness display Versatility of installation: wall-mounted, ceiling, flag style, suspension etc.
KIT LV ISO Kit with pictograms for all the signs (arrow right, left, down)
Protection rating IP40 Possibility of choosing the brightness level Power supply: 230 Vac 50-60 Hz Maximum battery recharging time: 12h
ACCESSORIES TO BE ORDERED SEPARATELY
Die-cast aluminium body Compliant with European standards EN 60598-1, EN 605982-22
OR KT SOS Kit for suspension fastening for ORION with steel cables
Photobiological hazard free according to standard EN 62471
New European Pictograms ORION uses the new standardized European pictograms. ORDER CODE
5 5
SHORT CODE
CONSUM.* DURAT. (W)
OR32N10AGR OR32N30AGR
OR 1201 OR 1202
3 1,7
OR32N10AGRT OR32N30AGRT
OR 1301 OR 1302
3 1,7
OR32N10AGRC OR32N30AGRC
OR 1501 OR 1502
3 1,7
OR32N10AGRW OR32N30AGRW
OR 2401 OR 2402
3,1 1,8
OR32N10AGRD OR32N30AGRD OR32000IGS-D
OR 1601 OR 1602 OR 1603
3 1,7 2
OR32000IGS
OR 1901
TYPE VISIBILITY
BATTERY
ORDER CODE
SHORT CODE
DESCRIPTION
ORKTSOS ORKTSTAFFA-G ORKTSTAFFA-B KITLVISO COMMANDER
A037 A077 A093 A163 CN0001
KIT FOR SUSPENSION INSTALLATION ORION KIT FOR FLAG-STYLE AND WALL FASTENING GREY KIT FOR FLAG-STYLE AND WALL FASTENING WHITE PICTOGRAMS FOR LYRA EVO CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
ORDER CODE
SHORT CODE
CONSUM.* DURAT. (W)
GREY
WHITE
REST MODE
REST MODE
1h 3h
M M
32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
5
OR32N10ABR OR32N30ABR
OR 1203 OR 1204
3 1,7
M M
32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
5
OR32N10ABRT OR32N30ABRT
OR 1303 OR 1304
3 1,7
M M
32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
5
OR32N10ABRC OR32N30ABRC
OR 1503 OR 1504
3 1,7
M M
32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
OR32N10ABRW OR32N30ABRW
OR 2403 OR 2404
3,1 1,8
M M L
32 meters 32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
OR32N10ABRD OR32N30ABRD OR32000IBS-D
OR 1604 OR 1605 OR 1606
3 1,7 2
L
32 meters
OR32000IBS
OR 1902
5
ENERGY TEST 5 5
1h 3h
5
1h 3h
5
5
2
OR32000IGS-SC
OR 2001
2
OR 2101
0,8
1h 3h
M M
32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
1h 3h
M M
32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
1h 3h
M M
32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
1h 3h
M M L
32 meters 32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
2
L
32 meters
L
32 meters
L
32 meters
SPY CENTER L
32 meters
5
OR32000IBS-SC
OR 2002
SPY CENTER 24 OR32000IGS-SC24
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
CENTRAL BATTERY 5
SPY CENTER 5
32 meters 32 meters
DALI
CENTRAL BATTERY 5
M M
SPY SYSTEM WIRELESS
DALI 1h 3h
1h 3h
BATTERY
SPY SYSTEM
SPY SYSTEM WIRELESS 1h 3h
TYPE VISIBILITY
20 1 1 1 1
ENERGY TEST
SPY SYSTEM 5
PACK
2
SPY CENTER 24 L
32 meters
OR32000IBS-SC24
OR 2102
0,8
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
105
TY
FIV
E YEA
R
Lyra Evo
TM
ARRAN
W
106106
LED TECHNOLOGY SIGNALLING LUMINAIRES
32 m
22 m
Available in 22m and 32m versions LYRA EVO is a signalling luminaire with highbrightness white leds, which uniformly diffuse light over the entire screen. Aesthetically suitable for all settings.
PROTECTION RATING IP40 - IK08 VISUAL RANGE 22 m AND 32 m
C
A
KEY FOR SETTING THE LEVEL OF BRIGHTNESS IN THE PRESENCE OF A NETWORK, FOR USE IN CINEMAS AND THEATRES
D
CAN BE INSTALLED ON 503 BOXES B E
MAXIMUM BATTERY RECHARGING TIME: 12h INSTALLATION: CEILING, WALL, FLAG STYLE, RECESSED AND SUSPENDED USING SMALL CHAINS
F
VISIBILITY 32 M
A=289 mm B=261 mm C=34 mm D=77 mm E=185 mm F=280 mm
VISIBILITY 22 M
A=289 mm B=211 mm C=34 mm D=77 mm E=134 mm F=280 mm
ENERGY CONSUMPTION
106
POWER SUPPLY: 230 VAC 50-60 HZ
METHOD OF USE
CONSUMPTION
LYRA EVO MAINTAINED
1.7 W
LYRA EVO MOVIE - BRIGHTNESS REDUCED BY PUSH BUTTON
1W
LYRA EVO NON-MAINTAINED
0.8 W
INSTALLABLE WITH DOUBLE AND SINGLE SIDE WITH PICTOGRAMS KIT SUPPLIED AS PER STANDARD COMPLIANT WITH EUROPEAN STANDARDS EN 60598-1, EN 60598-2-22 PHOTOBIOLOGICAL HAZARD FREE ACCORDING TO STANDARD EN 62471
IP40 ï&#x20AC;&#x192; documentation@linergy.it |
IK08
PACK
3
technical support 334 1133875
106106
LED TECHNOLOGY SIGNALLING LUMINAIRES
Lyra Evo STANDARD ACCESSORIACCESSORIES
TEST BUTTON
LV KT FB Bracket for flag style fastening The bracket is flexible on the 503 box for the flag style installation of the LYRA EVO ceiling light.
Allows the manual functional test to be performed also in the REST MODE models. Allows reduction of the luminous intensity in those situations where a low light flux is required when the mains voltage is present. Ideal for cinemas and theatres.
LV KT FS Bracket for ceiling fastening For the ceiling installation of the LYRA EVO. KIT LV ISO - KIT LV ISO-22 Kit with pictograms for all the signs (arrow right, left, down) Available in 22m and 32m versions
ACCESSORIES ACCESSORI TO BE ORDERED SEPARATELY LV KT SOS Kit for suspension installation The kit includes the eyelets and small chains for the suspended fastening of the LYRA EVO.
New European Pictograms LYRA EVO uses the new standardized European pictograms.
ORDER CODE
SHORT CODE
DESCRIPTION
GRIG05 LVKTFB LVKTFP LVKTFS LVKTINC LVKTSOS KITLVISO KITLVISO-22 COMMANDER
A016 A031 A032 A033 A034 A035 A163 A164 CN0001
PROTECTIVE GRATING CLASP FOR FLAG-STYLE FASTENING LYRA EVO CLASP FOR WALL FASTENING LYRA EVO CLASP FOR CEILING FASTENING LYRA EVO KIT FOR INSTALL. ON A DROPPED-CEILING LYRA EVO KIT FOR SUSPENSION INSTALLATION LYRA EVO PICTOGRAMS FOR LYRA EVO PICTOGRAMS FOR LYRA EVO 22M CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
LV KT INC Kit for recessed installation on a false ceiling So as to leave only the signalling panel visible; this kit allows for the recessed installation of the LYRA EVO. LV KT FP Bracket for wall fastening It is needed for the wall-installation of the LYRA EVO using the fastenings of the 503 box.
PACK
ORDER CODE
SHORT CODE
CONSUMPTION * (W)
LV22N10ABR LV22N30ABR LV32N10ABR LV32N30ABR
LV 1201 LV 1202 LV 1203 LV 1204
1,7 1,7 1,7 1,7
LV22N10ABRT LV22N30ABRT LV32N10ABRT LV32N30ABRT
LV 1301 LV 1302 LV 1303 LV 1304
1,7 1,7 1,7 1,7
LV22N10ABRC LV22N30ABRC LV32N10ABRC LV32N30ABRC
LV 1501 LV 1502 LV 1503 LV 1504
1,7 1,7 1,7 1,7
LV22N10ABRW LV22N30ABRW LV32N10ABRW LV32N30ABRW
LV 2401 LV 2402 LV 2403 LV 2404
1,8 1,8 1,8 1,8
LV22N10ABRD LV22N30ABRD LV32N10ABRD LV32N30ABRD LV22000IBS-D LV32000IBS-D
LV 1601 LV 1602 LV 1603 LV 1604 LV 1605 LV 1606
1,7 1,7 1,7 1,7 1,3 1,3
LV22000IBS LV32000IBS
LV 1901 LV 1902
1,3 1,3
LV22000IBS-SC LV32000IBS-SC
LV 2001 LV 2002
1,3 1,3
LV22000IBS-SC24 LV32000IBS-SC24
LV 2101 LV 2102
0,8 0,8
10 1 1 40 20 20 1 1 1
GRIG05 Protective grating - Made in galvanised metal for complete protection of the luminaire body against accidental blows or acts of vandalism. Only for wall mounting in combination with the LV KT FP kit
DURATION
TYPE
VISIBILITY
BATTERY
M M M M
22 meters 22 meters 32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
M M M M
22 meters 22 meters 32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
M M M M
22 meters 22 meters 32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
M M M M
22 meters 22 meters 32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
M M M M L L
22 meters 22 meters 32 meters 32 meters 22 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
L L
22 meters 32 meters
L L
22 meters 32 meters
L L
22 meters 32 meters
REST MODE 1h 3h 1h 3h
ENERGY TEST 1h 3h 1h 3h
SPY SYSTEM 1h 3h 1h 3h
SPY SYSTEM WIRELESS 1h 3h 1h 3h
DALI 1h 3h 1h 3h
CENTRAL BATTERY SPY CENTER SPY CENTER 24
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
107
TY
FIV
E YEA
R
Lexit
TM
ARRAN
W
108108
LED TECHNOLOGY SIGNALLING LUMINAIRES
IP65
Guaranteed for outdoor settings LEXIT is a Led signalling luminaire with IP65 protection rating, which makes it fit for use outdoors: industrial sheds, parking lots, warehouses, garages. The Led light source ensures high lighting performance and a distance of visibility up to 32 m.
PROTECTION RATING IP65
C
A
INSTALLATION ON 503 BOXES POWER SUPPLY 230VAC 50-60HZ
D
MAXIMUM RECHARGING TIME: 12h B
INSTALLATION: CEILING, FLAG STYLE AND WALL USING THE ACCESSORIES SUPPLIED AS STANDARD
E
F
G
A=309 mm B=283 mm C=41 mm D=99 mm E=185 mm F=290 mm G=8 mm
INSTALLATION WITH DOUBLE AND SINGLE SIDE WITH PICTOGRAMS KIT SUPPLIED AS PER STANDARD COMPLIANT WITH EUROPEAN STANDARDS EN 60598-1, EN 60598-2-22 PHOTOBIOLOGICAL HAZARD FREE ACCORDING TO STANDARD EN 62471
ENERGY CONSUMPTION
108
DURATION: 1h - 3h
METHOD OF USE
CONSUMPTION
LEXIT MAINTAINED
3W
LEXIT NON-MAINTAINED
0.8 W
IP65 ï&#x20AC;&#x192; documentation@linergy.it |
PACK
3
technical support 334 1133875
108108
LED TECHNOLOGY SIGNALLING LUMINAIRES
Lexit STANDARD ACCESSORIACCESSORIES LV KT FB Bracket for flag style fastening The bracket is flexible on the 503 box for the flag style installation of the LEXIT ceiling light. LV KT FS Bracket for ceiling fastening For the ceiling installation of the LEXIT.
KIT LV ISO Kit with pictograms for all the signs (arrow right, left, down)
ACCESSORIES ACCESSORI TO BE ORDERED SEPARATELY
ORDER CODE
SHORT CODE
DESCRIPTION
GRIG05 LVKTFB LVKTFP LVKTFS LVKTSOS LXKTINC KITLVISO COMMANDER
A016 A031 A032 A033 A035 A036 A163 CN0001
PROTECTIVE GRATING CLASP FOR FLAG-STYLE FASTENING LYRA EVO CLASP FOR WALL FASTENING LYRA EVO CLASP FOR CEILING FASTENING LYRA EVO KIT FOR SUSPENSION INSTALLATION LYRA EVO KIT FOR INSTALL. ON A DROPPED-CEILING LEXIT PICTOGRAMS FOR LYRA EVO CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
LV KT SOS Kit for suspension installation The kit includes the eyelets and small chains for the suspended fastening of the LEXIT.
PACK 10 1 1 40 20 20 1 1
LX KT INC Kit for recessed installation on a false ceiling So as to leave only the signalling panel visible; this kit allows for the recessed installation of the LEXIT. LV KT FP Bracket for wall fastening It is needed for the wall-installation of the LEXIT using the fastenings of the 503 box. GRIG05 Protective grating - Made in galvanised metal for complete protection of the luminaire body against accidental blows or acts of vandalism. Only for wall mounting in combination with the LV KT FP kit
New European Pictograms LEXIT uses the new standardized European pictograms.
ORDER CODE
SHORT CODE
CONSUMPTION * (W)
LX32N10ABR LX32N30ABR
LX 1201 LX 1202
3 1,7
LX32N10ABRT LX32N30ABRT
LX 1301 LX 1302
3 1,7
LX32N10ABRC LX32N30ABRC
LX 1501 LX 1502
3 1,7
LX32N10ABRW LX32N30ABRW
LX 2401 LX 2402
3,1 1,8
LX32N10ABRD LX32N30ABRD LX32000IBS-D
LX 1601 LX 1602 LX 1603
3 1,7 2
LX32000IBS
LX 1901
2
DURATION
TYPE
VISIBILITY
BATTERY
M M
32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
M M
32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
M M
32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
M M
32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
M M L
32 meters 32 meters 32 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
L
32 meters
L
32 meters
L
32 meters
REST MODE 1h 3h
ENERGY TEST 1h 3h
SPY SYSTEM 1h 3h
SPY SYSTEM WIRELESS 1h 3h
DALI 1h 3h
CENTRAL BATTERY SPY CENTER LX32000IBS-SC
LX 2001
2
SPY CENTER 24 LX32000IBS-SC24
LX 2101
0,8
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
109
TY
FIV
E YEA
R
Astra
TM
ARRAN
W
110110
LED TECHNOLOGY SIGNALLING LUMINAIRES
32 m
22 m
ASTRA is a Led signalling luminaire that is innovative thanks to its versatility of installation: only one bracket for 3 types of installation and selectable light duration according to need. It is aesthetically pleasing for all environments. SELECTABLE DURATION: 1h, 2h, 3h IP40 PROTECTION RATING VIEW DISTANCE OF 22m AND 32m FEATURES ADJUSTABLE OUTPUT LIGHTING WHEN POWERED BY MAINS, OR USE IN CINEMAS AND THEATRES
C
A
D
INSTALLABLE ON 503 BOXES SUPPLY VOLTAGE: 230 Vac 50-60 Hz B
E
MAXIMUM BATTERY CHARGE TIME OF 12h INSTALLATION: CEILING, WALL, FLAG STYLE, RECESSED AND SUSPENDED ONE- OR TWO-SIDE INSTALLATION WITH PICTOGRAM KIT SUPPLIED
F
VISIBILITY 32 M
A=271 mm B=206 mm C=33 mm D=43 mm E=163 mm F=255 mm
ALSO FEATURES IN NON MAINTAINED OPERATION (N/M) MODE
VISIBILITY 22 M
A=271 mm B=167 mm C=33 mm D=43 mm E=123 mm F=255 mm
COMPLIANT WITH EUROPEAN STANDARDS EN 60598-1, EN 60598-2-22, EN 1838
ENERGY CONSUMPTION
110
METHOD OF USE
CONSUMPTION
ASTRA MAINTAINED
2.9 W
ASTRA MOVIE
0.6 W
ASTRA NON-MAINTAINED
0.3 W
NO PHOTOBIOLOGICAL RISK COMPLIANT WITH EN 62471
IP40 ï&#x20AC;&#x192; documentation@linergy.it |
PACK
6
technical support 334 1133875
110110
LED TECHNOLOGY SIGNALLING LUMINAIRES
Astra SINGLE BRACKET SUPPLIED
STANDARD ACCESSORIACCESSORIES KIT AS ISO-22 - KIT AS ISO-32 Kit with pictograms for all the signs (arrow right, left, down) Available in 22m and 32m versions
ACCESSORIES ACCESSORI TO BE ORDERED SEPARATELY AS KT SOS Kit for suspension installation The kit includes the eyelets and small chains for the suspended fastening of the ASTRA.
Ceiling mount
AS KT INC Kit for recessed installation on a false ceiling So as to leave only the signalling panel visible; this kit allows for the recessed installation of the ASTRA.
Wall mount
AS KT 503 Bracket for wall fastening It is needed for the wall-installation of the ASTRA using the fastenings of the 503 box. GRIG05 Protective grating Made in galvanised metal for complete protection of the luminaire body against accidental blows or acts of vandalism. Only for wall mounting
Flag style
KIT ALIM AS Kit consisting of wires and connector for connection with interruptible permanent lighting and/or rest mode by means of Commander.
Li-FePO4 BATTERY SERVICE EFFICIENCY New European Pictograms ASTRA uses the new standardized European pictograms.
Li-FePO4 NiMH
ORDER CODE
SHORT CODE
DESCRIPTION
ASKTINC ASKTSOS GRIG05 ASKT503 ASKTSTAF KITASISO-22 KITASISO-32 KITALIMAS
A001 A002 A016 A068 A081 A161 A162 A252
KIT FOR INSTALL. ON A DROPPED-CEILING ASTRA KIT FOR SUSPENSION INSTALLATION ASTRA PROTECTIVE GRATING BRACKET FLUSH BOX 503 SERIES ASTRA BRACKET SERIES ASTRA PICTOGRAMS FOR ASTRA 22M PICTOGRAMS FOR ASTRA 32M KIT FOR PERMANENT SWITCHING/REST MODE FOR ASTRA
PACK 20 20 10 20 20 1 1 1
NiCd Pb OVER 5 YEARS
LIFETIME
ORDER CODE
SHORT CODE
CONSUMPTION * (W)
AS22F30ABR AS32F30ABR
AS 1201 AS 1202
2,9 2,9
DURATION
TYPE
VISIBILITY
BATTERY
M M
22 meters 32 meters
Li-FePO4 3,2V 1,5Ah Li-FePO4 3,2V 1,5Ah
REST MODE 1 h/2 h/3 h 1 h/2 h/3 h
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged.
111
TY
FIV
E YEA
R
Swing
TM
ARRAN
W
112112
LED TECHNOLOGY SIGNALLING LUMINAIRES
SWING is an elegantly designed signalling luminaire for suspension installation in ceiling/ fitting mounting or for plaster board recessed mounting.
BODY IN ANODIZED ALUMINIUM 14 LED FOR INCREASED BRIGHTNESS C
VIEW DISTANCE OF 30m
A
ONE- OR TWO-FACE INSTALLATION WITH PICTOGRAM KIT SUPPLIED AS STANDARD
B
SUSPENSION INSTALLATION ALSO FEATURES IN NON MAINTAINED OPERATION (N/M) MODE
D E
PACK
IP30 F
A=305 mm B=55 mm C=35 mm D=300 mm E=15 mm F=188 mm G=225 mm
RECESSED
G
PACK CEILING
6
ENERGY CONSUMPTION METHOD OF USE
CONSUMPTION
SWING MAINTAINED
3.0 W
SWING NON-MAINTAINED
0.8 W
ï&#x20AC;&#x192; documentation@linergy.it |
112
2
technical support 334 1133875
112112
LED TECHNOLOGY SIGNALLING LUMINAIRES
Swing ACCESSORI METHOD OF INSTALLATION
STANDARD ACCESSORIACCESSORIES KIT SW ISO Kit with pictograms for all the signs (arrow right, left, down)
Ceiling
New European Pictograms SWING uses the new standardized European pictograms.
Recessed
ORDER CODE
SHORT CODE
DESCRIPTION
KITSWISO COMMANDER
A167 CN0001
PICTOGRAMS FOR SWING CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
PACK 1 1
High-visibility white Led light source High-visibility panel IP30 protection rating Supply voltage: 230 Vac 50-60 Hz Maximum battery charge time: 12h Body in anodized aluminium Compliant with European standards EN 60598-1, EN 60598-2-22, EN 1838 No photobiological risk compliant with EN 62471 ORDER CODE
SHORT CODE
CONSUM.* DURAT. (W)
TYPE VISIBILITY
BATTERY
ORDER CODE
SHORT CODE
RECESSED INSTALLATION
CONSUM.* DURAT. (W)
SU 1201 SU 1202
3 1,7
SU30N10AGRT SU30N30AGRT
SU 1301 SU 1302
3 1,7
SU30N10AGRC SU30N30AGRC
SU 1501 SU 1502
3 1,7
SU30N10AGRW SU30N30AGRW
SU 2401 SU 2402
3,1 1,8
SU30N10AGRD SU30N30AGRD SU30000IGS-D
SU 1601 SU 1602 SU 1603
3 1,7 2
SU30000IGS
SU 1901
1h 3h
REST MODE M M
30 meters 30 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
SW30N10AGR SW30N30AGR
SW 1201 SW 1202
3 1,7
M M
30 meters 30 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
SW30N10AGRT SW30N30AGRT
SW 1301 SW 1302
3 1,7
M M
30 meters 30 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
SW30N10AGRC SW30N30AGRC
SW 1501 SW 1502
3 1,7
M M
30 meters 30 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
SW30N10AGRW SW30N30AGRW
SW 2401 SW 2402
3,1 1,8
M M L
30 meters 30 meters 30 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
SW30N10AGRD SW30N30AGRD SW30000IGS-D
SW 1601 SW 1602 SW 1603
3 1,7 2
L
30 meters
SW30000IGS
SW 1901
ENERGY TEST 1h 3h
SU 2001
2
SU 2101
L
0,8
M M
30 meters 30 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
1h 3h
M M
30 meters 30 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
1h 3h
M M
30 meters 30 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
1h 3h
M M L
30 meters 30 meters 30 meters
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
2
L
30 meters
L
30 meters
L
30 meters
SPY CENTER 30 meters
SW30000IGS-SC
SW 2001
SPY CENTER 24 SU3000IGS-SC24
1h 3h
CENTRAL BATTERY
SPY CENTER SU30000IGS-SC
Ni-Cd 4,8V 0,5Ah Ni-Cd 4,8V 0,5Ah
DALI
CENTRAL BATTERY 2
30 meters 30 meters
SPY SYSTEM WIRELESS
DALI 1h 3h
M M
SPY SYSTEM
SPY SYSTEM WIRELESS 1h 3h
1h 3h
ENERGY TEST
SPY SYSTEM 1h 3h
BATTERY
CEILING INSTALLATION
REST MODE SU30N10AGR SU30N30AGR
TYPE VISIBILITY
2
SPY CENTER 24 L
30 meters
SW3000IGS-SC24
SW 2101
0,8
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
113
TY
FIV
R
Big One
E YEA
ARRAN
W
114114
LED TECHNOLOGY SIGNALLING LUMINAIRES
80 m
180 led 132 led
60 m
visual range 80m visual range 60m
BIG ONE is a signalling luminaire with highbrightness white leds, which uniformly diffuse light over the entire screen. Ideal for large spaces, industrial sheds, fairs.
A
C
DURATION: 1 h - 3 h LIGHT SOURCE: 180 - 132 LED B
PROTECTION RATING IP40 POWER SUPPLY: 230 VAC 50-60 Hz MAX BATTERY RECHARGE TIME: 12H
VISIBILITY 80 M A=840 mm B=472 mm C=72 mm VISIBILITY 60 M A=646 mm B=377 mm C=72 mm
PICTOGRAMS IN PVC TO BE ORDERED SEPARATELY WHITE PAINTED METAL BODY NOT MAINTAINED (N/M) OPERATION OPTION COMPLIANT WITH EUROPEAN STANDARDS EN 60598-1, EN 60598-2-22 PHOTOBIOLOGICAL HAZARD FREE ACCORDING TO STANDARD EN 62471
IP40
PACK
1
Low environmental impact ï&#x20AC;&#x192; documentation@linergy.it |
114
technical support 334 1133875
114114
LED TECHNOLOGY SIGNALLING LUMINAIRES
Big One STANDARD ACCESSORIACCESSORIES
ACCESSORIES TO BE ORDERED SEPARATELY
Wall-mounted
Suspended
Ceiling
Pictograms
VISUAL RANGE 80m / 60m New European Pictograms BIG ONE uses the new standardized European pictograms.
BG60IS01 BG80IS01
BG60IS02 BG80IS02
BG60IS08-A BG80IS08-A
BG60IS08-B BG80IS08-B
ORDER CODE
SHORT CODE
CONSUMPTION * (W)
BG60N10ABR BG60N30ABR BG80N10ABR BG80N30ABR
BG 1201 BG 1202 BG 1203 BG 1204
9,4 10,7 10,2 12
BG60N10ABRT BG60N30ABRT BG80N10ABRT BG80N30ABRT
BG 1301 BG 1302 BG 1303 BG 1304
9,4 10,7 10,2 12
BG60N10ABRC BG60N30ABRC BG80N10ABRC BG80N30ABRC
BG 1501 BG 1502 BG 1503 BG 1504
9,4 10,7 10,2 12
BG60N10ABRW BG60N30ABRW BG80N10ABRW BG80N30ABRW
BG 2401 BG 2402 BG 2403 BG 2404
9,5 10,8 10,3 12,1
BG60000IBS BG80000IBS
BG 1901 BG 1902
15 20
BG60000IBS-SC BG80000IBS-SC
BG 2001 BG 2002
15 20
ORDER CODE
SHORT CODE
DESCRIPTION
BGKTSOS BG60IS01 BG60IS02 BG60IS08-A BG60IS08-B BG80IS01 BG80IS02 BG80IS08-A BG80IS08-B COMMANDER
A003 A136 A137 A139 A140 A141 A142 A144 A145 CN0001
KIT FOR SUSPENSION INSTALLATION BIG ONE PICTOGRAM FOR BIG ONE 60M IS01 PICTOGRAM FOR BIG ONE 60M IS02 PICTOGRAM FOR BIG ONE 60M IS08 PICTOGRAM FOR BIG ONE 60M IS08 PICTOGRAM FOR BIG ONE 80M IS01 PICTOGRAM FOR BIG ONE 80M IS02 PICTOGRAM FOR BIG ONE 80M IS08 PICTOGRAM FOR BIG ONE 80M IS08 CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
DURATION
PACK
TYPE
VISIBILITY
BATTERY
M M M M
60 meters 60 meters 80 meters 80 meters
Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
M M M M
60 meters 60 meters 80 meters 80 meters
Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
M M M M
60 meters 60 meters 80 meters 80 meters
Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
M M M M
60 meters 60 meters 80 meters 80 meters
Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
L L
60 meters 80 meters
L L
60 meters 80 meters
20 1 1 1 1 1 1 1 1 1
REST MODE 1h 3h 1h 3h
ENERGY TEST 1h 3h 1h 3h
SPY SYSTEM 1h 3h 1h 3h
SPY SYSTEM WIRELESS 1h 3h 1h 3h
CENTRAL BATTERY
SPY CENTER
* Note: the power (expressed in W) absorbed by the appliance is intended when the battery is charged. The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39. The product is factory set to operate with the COMMANDER in the REST MODE mode. For info: support@linergy.it
115
116116
LED TECHNOLOGY SIGNALLING LUMINAIRES
Qube
44 m
26 m
Cube-shaped, QUBE is the ideal device for the correct identification of escape routes. The two dimensions and the pictograms supplied make it a practical and versatile solution.
VISUAL RANGE 26 m AND 44 m PROTECTION RATING: IP32 (26m) - IP43 (44m) POWER SUPPLY: 230 VAC 50-60 Hz WALL AND CEILING INSTALLATION. INSTALLATION WITH 50 OR 100CM RIGID EXTRUDED ALUMINUM ROD. INSTALLATION WITH CHAINS (BY ORDERING THE DEDICATED KIT) IT ADAPTS PERFECTLY TO ENVIRONMENTS WITH TEMPERATURE THAT VARIES FROM -5 °C TO +40 °C TEST BUTTON TO VERIFY CORRECT OPERATION IN EMERGENCY MODE C
A
B
KIT WITH PICTOGRAMS SUPPLIED AS STANDARD COMPLIANT WITH EUROPEAN STANDARDS EN 60598-1, EN 60598-2-22, EN 1838 PHOTOBIOLOGICAL HAZARD FREE ACCORDING TO STANDARD EN 62471
VISIBILITY 44 M A=250 mm B=270 mm C=250 mm VISIBILITY 26 M A=175 mm B=179 mm C=175 mm
116
IP43 44m IP32 26m
documentation@linergy.it |
PACK
1
technical support 334 1133875
116116
LED TECHNOLOGY SIGNALLING LUMINAIRES
Qube
ACCESSORI TO BE ORDERED SEPARATELY ACCESSORIES
STANDARD ACCESSORIACCESSORIES KIT QU 26 ISO KIT QU 44 ISO Kit with squared pictograms for all the signs (arrow right, left, down)
Suspension
ORDER CODE
SHORT CODE
DESCRIPTION
QUKTSOS QUPEND100 QUPEND50 KITQU26ISO KITQU44ISO
A040 A041 A042 A165 A166
KIT FOR SUSPENSION INSTALLATION QUBE KIT FOR QUBE PENDULUM 100CM KIT FOR QUBE PENDULUM 50CM PICTOGRAMS FOR QUBE PICTOGRAMS FOR QUBE
PACK 20 1 1 1 1
Rod
(ceiling fixing brackets not included)
ORDER CODE
SHORT CODE
DURATION
QU26N30EBST QU44N30EBST QU26N30ABST QU44N30ABST
QU 1301 QU 1302 QU 1303 QU 1304
3h 3h 3h 3h
QU26000IBS QU44000IBS
QU 1901 QU 1902
QU26000IBS-SC QU44000IBS-SC
QU 2001 QU 2002
QU26000IBS-SC24 QU44000IBS-SC24
QU 2101 QU 2102
TYPE
VISIBILITY
BATTERY
N/M N/M M M
26 meters 44 meters 26 meters 44 meters
Ni-Cd 3,6V 0,9Ah Ni-MH 3,6V 2,5Ah Ni-Cd 3,6V 0,9Ah Ni-MH 3,6V 2,5Ah
L L
26 meters 44 meters
L L
26 meters 44 meters
L L
26 meters 44 meters
ENERGY TEST
CENTRAL BATTERY
SPY CENTER
SPY CENTER 24
The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture.
117
118118
118
118118
FLUORESCENT EMERGENCY LUMINAIRES
119
120120
FLUORESCENT EMERGENCY LUMINAIRES
Cristal
Also high flux
CRISTAL is an easy to assemble luminaire and is ideal for large outdoor settings such as shopping centres, industrial sheds, car parks.
PERFECT FOR LARGE INDOOR AND OUTDOOR ENVIRONMENTS (hospitals, technical premises, shopping centres, schools, garages, gyms, work places) DECORATIVE FRAME SUPPLIED ON ALL INDIVIDUAL MODELS
C
INSTALLATION: WALL-MOUNTED, FLAG STYLE, CEILING AND RECESSED
A
HIGH FLUX UP TO 700 LUMEN B
IP40 A=380 mm B=180 mm C=68 mm
120
IP65
IK09
ï&#x20AC;&#x192; documentation@linergy.it |
PACK
6
technical support 334 1133875
120120
FLUORESCENT EMERGENCY LUMINAIRES
Cristal EVEN EASIER TO ASSEMBLE The luminaire is equipped with a wall base which allows a 16 mm tube to enter from three sides or from the bottom. The reflector is engaged with a simple movement towards the wall base; from today, even easier thanks to the centring guides.
Photometric diagrams Range Angles
The CRISTAL luminaire body attaches to the holder, whether it recessed or external. The ENERGY TEST version exercises constant control of the battery, the fluorescent tube and the entire luminaire. Perfect efficiency is always guaranteed by the immediate signalling of any breakdowns. It is available for maintained emergency lighting, non-maintained and for non-emergency lighting.
8W Range Angles
Protection rating IP40-IP65-IK09 Available in versions 8, 11, 18 and 24 W The fixtures with 12 hours recharge time guarantee 2 hours of duration Installation on surfaces that are normally flammable
11 W
Power supply: 230 Vac 50-60 Hz Range Angles
Available in versions with configurable rest mode and energy test Compliant with European standards EN 60598-1, EN 60598-2-22
18 W Range Angles
24 W
121
122122
FLUORESCENT EMERGENCY LUMINAIRES
Cristal ACCESSORIES
ELECTRIC CONNECTIONS
CR KT CGE Plasterboard and false ceiling fastening kit Kit for fixing the ceiling light on the plasterboard walls and false ceiling.
COMMANDER
A
COMMANDER
230~ SE
B
A
B
230~ SA
230~ SE
COMMANDER Controller for the remote management of rest mode Commander manages the rest status and carries out tests on the luminaire. On self-test models it allows for centralized control of the self-diagnosis functions. IP65 CONNECTOR IP65 fitting supplied The IP65 fitting is supplied with the product to engage a 16 mm tube to the luminaire body.
4 5 6 1 2 3
N/M models
INC M CR Wall box for recessed installation Dimensions (mm): internal 365.6 x 167.1 max external 382.7 x 184.2 GRIG02 Protective grating Made in galvanized metal for complete protection of the luminaire body against accidental blows or acts of vandalism. CR KT BLINDO Busway accessory Accessory that allows hook up to the busbar. CR KT SEG Signalling kit With this kit, CRISTAL can be used as a signal luminaire in compliance with EN 1838. Kit of pictograms supplied as standard. SM KT SUP Kit for flag style fastening Bracket for fixing the ceiling light in flag style. KIT 45 GRADI With this bracket, the luminaire can be installed with an inclination of 45°
122
4 5 6 1 2 3
M models
Pictograms: See the “Accessories and spare parts” section on page 154. Visual range with pictogram = 30 m.
CRIS01
CRIS02
CRIS08
ORDER CODE
SHORT CODE
DESCRIPTION
CRKTBLINDO CRKTCGE CRKTSEG GRIG02 INCMCR SMKTSUP KIT45GRADI CRIS01 CRIS02 CRIS08 CORNCR COMMANDER
A005 A006 A007 A013 A019 A047 A092 A149 A150 A151 A203 CN0001
BUSBAR KIT PLASTERBOARD AND DROPPED-CEILING FASTENING KIT SIGNALING KIT CRISTAL PROTECTIVE GRATING WALL BOX RECESSED INSTALLATION CRISTAL KIT FOR FLAG-STYLE FASTENING CLASP FOR FIXING AT 45 DEGREES PICTOGRAM FOR CRISTAL ARROW LEFT PICTOGRAM FOR CRISTAL ARROW RIGHT PICTOGRAM FOR CRISTAL ARROW DOWN AESTHETIC FRAME FOR CRISTAL CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
PACK 80 20 10 10 56 10 10 1 1 1 1 1
122122
FLUORESCENT EMERGENCY LUMINAIRES
Cristal ORDER CODE
SHORT CODE
LAMP
DURATION
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
N/M N/M N/M N/M N/M N/M N/M
130 130 172 162 180 219 316
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 0,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,3Ah
N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
193 188 172 229 180 219 316 335 198 199 218 251 210 238 311 343
Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
IP 40 INHIBIT CR08N10EGI CR08N30EGI CR11N10EGI CR11N30EGI CR18N10EGI CR18N30EGI CR24N10EGI
CR 1101 CR 1102 CR 1103 CR 1104 CR 1105 CR 1106 CR 1107
8W 8W 11W 11W 18W 18W 24W
1h 3h 1h 3h 1h 3h 1h
CR08N10EGR CR08N30EGR CR11N10EGR CR11N30EGR CR18N10EGR CR18N30EGR CR24N10EGR CR24N30EGR CR08N10AGR CR08N30AGR CR11N10AGR CR11N30AGR CR18N10AGR CR18N30AGR CR24N10AGR CR24N30AGR
CR 1201 CR 1202 CR 1203 CR 1204 CR 1205 CR 1206 CR 1207 CR 1208 CR 1209 CR 1210 CR 1211 CR 1212 CR 1213 CR 1214 CR 1215 CR 1216
8W 8W 11W 11W 18W 18W 24W 24W 8W 8W 11W 11W 18W 18W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
CR08N10EGR-H CR08N30EGR-H CR11N10EGR-H CR11N30EGR-H CR18N10EGR-H CR18N30EGR-H CR24N10EGR-H CR24N30EGR-H
CR 1217 CR 1218 CR 1219 CR 1220 CR 1221 CR 1222 CR 1223 CR 1224
8W 8W 11W 11W 18W 18W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h
CR08N10EGRT CR08N30EGRT CR11N10EGRT CR11N30EGRT CR18N10EGRT CR18N30EGRT CR24N10EGRT CR24N30EGRT CR08N10AGRT CR08N30AGRT CR11N10AGRT CR11N30AGRT CR18N10AGRT CR18N30AGRT CR24N10AGRT CR24N30AGRT
CR 1301 CR 1302 CR 1303 CR 1304 CR 1305 CR 1306 CR 1307 CR 1308 CR 1309 CR 1310 CR 1311 CR 1312 CR 1313 CR 1314 CR 1315 CR 1316
8W 8W 11W 11W 18W 18W 24W 24W 8W 8W 11W 11W 18W 18W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
CR08N10EGRT-H CR08N30EGRT-H CR11N10EGRT-H CR11N30EGRT-H CR18N10EGRT-H CR18N30EGRT-H CR24N10EGRT-H CR24N10EGRT-HH CR24N30EGRT-H CR24N10AGRT-HH
CR 1317 CR 1318 CR 1319 CR 1320 CR 1321 CR 1322 CR 1323 CR 1324 CR 1325 CR 1326
8W 8W 11W 11W 18W 18W 24W 24W 24W 24W
REST MODE
334 332 416 414 328 328 497 497
REST MODE HIGH FLUX N/M N/M N/M N/M N/M N/M N/M N/M
254 259 343 326 310 323 548 495
Ni-Cd 6V 1,3Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah
193 188 172 229 180 219 316 335 198 199 218 251 210 238 311 343
334 332 416 414 328 328 497 497
Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
750
Ni-Cd 6V 1,3Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah Ni-MH 6V 3,8Ah HT
334 332 416 414 328 328 497 497
Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
ENERGY TEST N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
ENERGY TEST HIGH FLUX 1h 3h 1h 3h 1h 3h 1h 1h 3h 1h
N/M N/M N/M N/M N/M N/M N/M N/M N/M M
254 259 343 326 310 323 548 700 495 700
SPY SYSTEM CR08N10EGRC CR08N30EGRC CR11N10EGRC CR11N30EGRC CR18N10EGRC CR18N30EGRC CR24N10EGRC CR24N30EGRC CR08N10AGRC CR08N30AGRC CR11N10AGRC CR11N30AGRC CR18N10AGRC CR18N30AGRC CR24N10AGRC CR24N30AGRC
CR 1501 CR 1502 CR 1503 CR 1504 CR 1505 CR 1506 CR 1507 CR 1508 CR 1509 CR 1510 CR 1511 CR 1512 CR 1513 CR 1514 CR 1515 CR 1516
8W 8W 11W 11W 18W 18W 24W 24W 8W 8W 11W 11W 18W 18W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
193 188 172 229 180 219 316 335 198 199 218 251 210 238 311 343
123
124124
FLUORESCENT EMERGENCY LUMINAIRES
Cristal ORDER CODE
SHORT CODE
LAMP
CR08N10EGRC-H CR08N30EGRC-H CR11N10EGRC-H CR11N30EGRC-H CR18N10EGRC-H CR18N30EGRC-H CR24N10EGRC-H CR24N10EGRC-HH CR24N30EGRC-H CR24N10AGRC-HH
CR 1517 CR 1518 CR 1519 CR 1520 CR 1521 CR 1522 CR 1523 CR 1524 CR 1525 CR 1526
8W 8W 11W 11W 18W 18W 24W 24W 24W 24W
DURATION
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
SPY SYSTEM HIGH FLUX 1h 3h 1h 3h 1h 3h 1h 1h 3h 1h
N/M N/M N/M N/M N/M N/M N/M N/M N/M M
254 259 343 326 310 323 548 700 495 700
750
Ni-Cd 6V 1,3Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah Ni-MH 6V 3,8Ah HT
CENTRAL BATTERY CR08000IGS CR11000IGS CR18000IGS CR24000IGS
CR 1901 CR 1902 CR 1903 CR 1904
8W 11W 18W 24W
CR24000IGS-H
CR 1905
24W
L L L L
334 416 328 497
CENTRAL BATTERY HIGH FLUX L
750
L L L L
334 416 328 497
SPY CENTER CR08000IGS-SC CR11000IGS-SC CR18000IGS-SC CR24000IGS-SC
CR 2001 CR 2002 CR 2003 CR 2004
8W 11W 18W 24W
CR24000IGS-SC-H
CR 2005
24W
SPY CENTER HIGH FLUX L
750
IP 65 INHIBIT CS08N10EGI CS08N30EGI CS11N10EGI CS11N30EGI CS18N10EGI CS18N30EGI CS24N10EGI
CS 1101 CS 1102 CS 1103 CS 1104 CS 1105 CS 1106 CS 1107
8W 8W 11W 11W 18W 18W 24W
1h 3h 1h 3h 1h 3h 1h
CS08N10EGR CS08N30EGR CS11N10EGR CS11N30EGR CS18N10EGR CS18N30EGR CS24N10EGR CS24N30EGR CS08N10AGR CS08N30AGR CS11N10AGR CS11N30AGR CS18N10AGR CS18N30AGR CS24N10AGR CS24N30AGR
CS 1201 CS 1202 CS 1203 CS 1204 CS 1205 CS 1206 CS 1207 CS 1208 CS 1209 CS 1210 CS 1211 CS 1212 CS 1213 CS 1214 CS 1215 CS 1216
8W 8W 11W 11W 18W 18W 24W 24W 8W 8W 11W 11W 18W 18W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
CS08N10EGR-H CS08N30EGR-H CS11N10EGR-H CS11N30EGR-H CS18N10EGR-H CS18N30EGR-H CS24N10EGR-H CS24N30EGR-H
CS 1217 CS 1218 CS 1219 CS 1220 CS 1221 CS 1222 CS 1223 CS 1224
8W 8W 11W 11W 18W 18W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h
CS08N10EGRT CS08N30EGRT CS11N10EGRT CS11N30EGRT CS18N10EGRT CS18N30EGRT CS24N10EGRT CS24N30EGRT CS08N10AGRT CS08N30AGRT CS11N10AGRT CS11N30AGRT CS18N10AGRT CS18N30AGRT CS24N10AGRT CS24N30AGRT RCS08N30AGRT RCS18N30AGRT
CS 1301 CS 1302 CS 1303 CS 1304 CS 1305 CS 1306 CS 1307 CS 1308 CS 1309 CS 1310 CS 1311 CS 1312 CS 1313 CS 1314 CS 1315 CS 1316 CS 1317 CS 1318
8W 8W 11W 11W 18W 18W 24W 24W 8W 8W 11W 11W 18W 18W 24W 24W 8W 18W
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 3h 3h
N/M N/M N/M N/M N/M N/M N/M
130 130 172 162 180 219 316
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 0,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,3Ah
N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
193 188 172 229 180 219 316 335 198 199 218 251 210 238 311 343
Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
REST MODE
334 332 416 414 328 328 497 497
REST MODE HIGH FLUX N/M N/M N/M N/M N/M N/M N/M N/M
254 259 343 326 310 323 548 495
Ni-Cd 6V 1,3Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah
193 188 172 229 180 219 316 335 198 199 218 251 210 238 311 343 184 220
Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-MH 6V 3,3Ah Ni-MH 6V 3,3Ah
ENERGY TEST
124
N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M M M
334 332 416 414 328 328 497 497 307 304
124124
FLUORESCENT EMERGENCY LUMINAIRES
Cristal ORDER CODE
SHORT CODE
LAMP
CS08N10EGRT-H CS08N30EGRT-H CS11N10EGRT-H CS11N30EGRT-H CS18N10EGRT-H CS18N30EGRT-H CS24N10EGRT-H CS24N10EGRT-HH CS24N30EGRT-H CS24N10AGRT-HH
CS 1319 CS 1320 CS 1321 CS 1322 CS 1323 CS 1324 CS 1325 CS 1326 CS 1327 CS 1328
8W 8W 11W 11W 18W 18W 24W 24W 24W 24W
DURATION
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
ENERGY TEST HIGH FLUX 1h 3h 1h 3h 1h 3h 1h 1h 3h 1h
N/M N/M N/M N/M N/M N/M N/M N/M N/M M
254 259 343 326 310 323 548 700 495 700
750
Ni-Cd 6V 1,3Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah Ni-MH 6V 3,8Ah HT
334 332 416 414 328 328 497 497
Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
750
Ni-Cd 6V 1,3Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah Ni-MH 6V 3,8Ah HT
SPY SYSTEM CS08N10EGRC CS08N30EGRC CS11N10EGRC CS11N30EGRC CS18N10EGRC CS18N30EGRC CS24N10EGRC CS24N30EGRC CS08N10AGRC CS08N30AGRC CS11N10AGRC CS11N30AGRC CS18N10AGRC CS18N30AGRC CS24N10AGRC CS24N30AGRC
CS 1501 CS 1502 CS 1503 CS 1504 CS 1505 CS 1506 CS 1507 CS 1508 CS 1509 CS 1510 CS 1511 CS 1512 CS 1513 CS 1514 CS 1515 CS 1516
8W 8W 11W 11W 18W 18W 24W 24W 8W 8W 11W 11W 18W 18W 24W 24W
CS08N10EGRC-H CS08N30EGRC-H CS11N10EGRC-H CS11N30EGRC-H CS18N10EGRC-H CS18N30EGRC-H CS24N10EGRC-H CS24N10EGRC-HH CS24N30EGRC-H CS24N10AGRC-HH
CS 1517 CS 1518 CS 1519 CS 1520 CS 1521 CS 1522 CS 1523 CS 1524 CS 1525 CS 1526
8W 8W 11W 11W 18W 18W 24W 24W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h
N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
193 188 172 229 180 219 316 335 198 199 218 251 210 238 311 343
SPY SYSTEM HIGH FLUX 1h 3h 1h 3h 1h 3h 1h 1h 3h 1h
N/M N/M N/M N/M N/M N/M N/M N/M N/M M
254 259 343 326 310 323 548 700 495 700
CENTRAL BATTERY CS08000IGS CS11000IGS CS18000IGS CS24000IGS
CS 1901 CS 1902 CS 1903 CS 1904
8W 11W 18W 24W
CS24000IGS-H
CS 1905
24W
L L L L
334 416 328 497
CENTRAL BATTERY HIGH FLUX L
750
L L L L
334 416 328 497
SPY CENTER CS08000IGS-SC CS11000IGS-SC CS18000IGS-SC CS24000IGS-SC
CS 2001 CS 2002 CS 2003 CS 2004
8W 11W 18W 24W
CS24000IGS-SC-H
CS 2005
24W
SPY CENTER HIGH FLUX L
750
The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it. The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
125
126126
FLUORESCENT EMERGENCY LUMINAIRES
Evolution Flu
®
Available also in other colours
EVOLUTION FLU is the natural completion of Ledy. Technologically ground breaking and aesthetically impeccable, it has an invaluable feature: a very affordable price.
IDEAL FOR LARGE INDOOR AND OUTDOOR SETTINGS (hospitals, technical rooms, shops, schools, gyms, homes, hotels) D
DECORATIVE FRAMES AND PLATE ARE AVAILABLE IN MANY COLOURS
E
INSTALLATION: WALL-MOUNTED, FLAG STYLE, CEILING AND RECESSED
C A
EASY TO ASSEMBLE AND INSTALL B
SUPPLIED IN WHITE AS PER STANDARD
IP42 A=350 mm B=177 mm C=52 mm D=25 mm E=20 mm
126
IP65
documentation@linergy.it |
PACK
10
technical support 334 1133875
126126
FLUORESCENT EMERGENCY LUMINAIRES
Evolution Flu
Available in versions 8, 11, 18, 24 W
INTERCHANGEABLE PLATES AND FRAMES Evolution Flu has an interchangeable system
Can also be installed onto surfaces that are normally flammable
PLATE
Protection rating IP42 - IP65
Power supply: 230 Vac 50-60 Hz The fixtures with 12 hours recharge time guarantee 2 hours of duration
UPPER FRAME
Compliant with European standards EN 60598-1, EN 60598-2-22
LOWER FRAME
The lamp can be customised aesthetically with the plates and trims made of different colours and materials. The many choices of colours and combinations allow EVOLUTION FLU to blend in with any environment, from the most modern to traditional.
PLATES
FRAMES
EL PL-B White finish
EL PL-N Black finish
EL PL-G Grey finish
EL CO SUP-B EL CO INF-B White finish
EL CO SUP-N EL CO INF-N Black finish
EL CO SUP-G EL CO INF-G Grey finish
EL PL-A Orange finish
EL P-V Green finish
EL PL-BL Blue finish
EL CO SUP-A EL CO INF-A Orange finish
EL CO SUP-V EL CO INF-V Green finish
EL CO SUP-BL EL CO INF-BL Blue finish
EL PL-R Red finish
EL PL-GI Yellow finish
EL PL-O Gold finish
EL CO SUP-R EL CO INF-R Red finish
EL CO SUP-GI EL CO INF-GI Yellow finish
EL CO SUP-O EL CO INF-O Gold finish
EL PL-FA Beech wood finish
EL PL-W Wenge finish
EL PL-NO Walnut finish
EL CO SUP-FA EL CO INF-FA Beech wood finish
EL CO SUP-W EL CO INF-W Wenge finish
EL CO SUP-NO EL CO INF-NO Walnut finish
127
128128
FLUORESCENT EMERGENCY LUMINAIRES
Evolution Flu ACCESSORIES EL KT CGE Plasterboard and false ceiling fastening kit Kit for wall-flush installation
Pictograms: See the “Accessories and spare parts” section on page 154. Visual range with pictogram = 21 m.
ST KT CGE Plasterboard and false ceiling fastening kit Kit for semi-recessed installation
ELIS01 COMMANDER Controller for the remote management of rest mode Commander manages the rest status and carries out tests on the luminaire. On self-test models it allows for centralized control of the self-diagnosis functions.
RTCA16 Tube/conduit fitting Practical fitting for use of tube measuring 16 mm for the entrance of cables towards the ceiling light. Dimensions (mm): internal 17.5 x 6.5 max external 20 x 10, h 32 INC M EL Wall box for recessed installation Dimensions (mm): internal 334 x 161.5 max external 346.4 x 173.9 GRIG04 Protective grating Made in galvanized metal for complete protection of the luminaire body against accidental blows or acts of vandalism.
CR KT BLINDO Busway accessory Accessory that allows hook up to the busbar.
EL KT SEG Signalling kit With this kit, EVOLUTION FLU can be used like a signalling luminaire in compliance with EN 1838 Standard. Kit of pictograms supplied as standard.
SM KT SUP Kit for flag style fastening Bracket for fixing the ceiling light in flag style.
KIT 45 GRADI With this bracket, the luminaire can be installed with an inclination of 45°
EL PLG-B Large white finishing plate* Ideal for wall recess installations with box and for false ceiling and plasterboard installation. * Available in black and grey on request
128
ELIS02
ELIS08
ORDER CODE
SHORT CODE
DESCRIPTION
CRKTBLINDO
A 005
BUSBAR KIT
80
CRKTBLINDO
A005
BUSBAR KIT
80
ELKTCGE
A009
PLASTERBOARD AND DROPPED-CEILING FASTENING KIT
20
ELKTSEG
A010
SIGNALING KIT
10
GRIG04
A015
PROTECTIVE GRATING
10
INCMEL
A020
WALL BOX RECESSED INSTALLATION EVOLUTION
20
INCMST
A024
WALL BOX RECESSED INSTALLATION STEP
50
SMKTSUP
A047
KIT FOR FLAG-STYLE FASTENING
10
KIT45GRADI
A092
CLASP FOR FIXING AT 45 DEGREES
10
ELIS01
A155
PICTOGRAMS FOR EVOLUTION L
1
ELIS02
A156
PICTOGRAMS FOR EVOLUTION R
1
ELIS08
A157
PICTOGRAMS FOR EVOLUTION LW
1
ELCOINF-N
A188
LOWER FRAME BLACK FOR EVOLUTION
1
PACK
ELCOSUP-N
A189
UPPER FRAME BLACK FOR EVOLUTION
1
ELPL-N
A190
BLACK PLATE FOR EVOLUTION
1
ELCOINF-BL
A193
LOWER FRAME BLUE FOR EVOLUTION
1
ELCOSUP-BL
A194
UPPER FRAME BLUE FOR EVOLUTION
1
ELPL-BL
A195
BLUE PLATE FOR EVOLUTION
1
ELCOINF-FA
A198
LOWER FRAME BEECH WOOD FOR EVOLUTION
1 1
ELCOSUP-FA
A199
UPPER FRAME BEECH WOOD FOR EVOLUTION
ELPL-FA
A200
BEECH WOOD PLATE FOR EVOLUTION
1
ELCOINF-G
A204
LOWER FRAME GREY FOR EVOLUTION
1
ELCOSUP-G
A205
UPPER FRAME GREY FOR EVOLUTION
1
ELPL-G
A206
GREY PLATE FOR EVOLUTION
1
ELCOINF-O
A209
LOWER FRAME GOLD FOR EVOLUTION
1
ELCOSUP-O
A210
UPPER FRAME GOLD FOR EVOLUTION
1
ELPL-O
A211
GOLD PLATE FOR EVOLUTION
1
ELCOINF-V
A214
LOWER FRAME GREEN FOR EVOLUTION
1
ELCOSUP-V
A215
UPPER FRAME GREEN FOR EVOLUTION
1
ELPL-V
A216
GREEN PLATE FOR EVOLUTION
1 1
ELCOINF-NO
A219
LOWER FRAME WALNUT FOR EVOLUTION
ELCOSUP-NO
A220
UPPER FRAME WALNUT FOR EVOLUTION
1
ELPL-NO
A221
WALNUT PLATE FOR EVOLUTION
1 1
ELCOINF-A
A224
LOWER FRAME ORANGE FOR EVOLUTION
ELCOSUP-A
A225
UPPER FRAME ORANGE FOR EVOLUTION
1
ELPL-A
A226
ORANGE PLATE FOR EVOLUTION
1
ELCOINF-R
A229
LOWER FRAME RED FOR EVOLUTION
1
ELCOSUP-R
A230
UPPER FRAME RED FOR EVOLUTION
1
ELPL-R
A231
RED PLATE FOR EVOLUTION
1
ELCOINF-B
A235
LOWER FRAME WHITE FOR EVOLUTION
1
ELCOSUP-B
A236
UPPER FRAME WHITE FOR EVOLUTION
1
ELPL-B
A237
WHITE PLATE FOR EVOLUTION
1
ELPLG-B
A238
WHITE BIG PLATE FOR EVOLUTION
1
ELCOINF-W
A241
LOWER FRAME WENGE FOR EVOLUTION
1 1
ELCOSUP-W
A242
UPPER FRAME WENGE FOR EVOLUTION
ELPL-W
A243
WENGE PLATE FOR EVOLUTION
1
ELCOINF-GI
A246
LOWER FRAME YELLOW FOR EVOLUTION
1
ELCOSUP-GI
A247
UPPER FRAME YELLOW FOR EVOLUTION
1
ELPL-GI
A248
YELLOW PLATE FOR EVOLUTION
1
COMMANDER
CN0001
CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
1
128128
FLUORESCENT EMERGENCY LUMINAIRES
Evolution Flu ELECTRIC CONNECTIONS
B A
230~ SE
Spare lamp 24W spare fluorescent lamp code: A131
230~ SE
230~ SA
Photometric diagrams
B A
Range Angles COMMANDER
N/M Models
COMMANDER
M Models
INSTALLATION VERSATILITY Evolution Flu can be wall-mounted, recessed or flush-wall installed. Fits perfectly also into the Step or wall-mounting box for semi-recessed installation.
8W Range Angles
52 mm
30 mm
10 mm
11 W Range Angles
Wall-mounted
Recessed onto STEP box
Recessed onto EVOLUTION box
INSTALLING THE IP65 VERSION 18 W Range Angles
The appliance is equipped with a pierceable membrane to ensure IP65 protection rating. Installation of the external visible pipes (Ã&#x2DC; 16 mm) is simplified in this way because no tools or press-fits are necessary.
24 W
129
130130
FLUORESCENT EMERGENCY LUMINAIRES
Evolution Flu ORDER CODE
SHORT CODE
LAMP
DURATION
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
N/M N/M N/M N/M N/M N/M N/M
80 80 173 171 113 92 228
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 0,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,3Ah
N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
210 211 461 276 205 162 321 205 189 188 292 289 165 163 238 237
354 356 438 435 286 284 489 489
Ni-Cd 6V 1,3Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
311 313 402 399 269 269 445 445
Ni-Cd 6V 1,3Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
IP 42 INHIBIT EF08N10EBI EF08N30EBI EF11N10EBI EF11N30EBI EF18N10EBI EF18N30EBI EF24N10EBI
EF 1101 EF 1102 EF 1103 EF 1104 EF 1105 EF 1106 EF 1107
8W 8W 11W 11W 18W 18W 24W
1h 3h 1h 3h 1h 3h 1h
EF08N10EBR EF08N30EBR EF11N10EBR EF11N30EBR EF18N10EBR EF18N30EBR EF24N10EBR EF24N30EBR EF08N10ABR EF08N30ABR EF11N10ABR EF11N20ABR EF18N10ABR EF18N30ABR EF24N10ABR EF24N30ABR
EF 1201 EF 1202 EF 1203 EF 1204 EF 1205 EF 1206 EF 1207 EF 1208 EF 1209 EF 1210 EF 1211 EF 1212 EF 1213 EF 1214 EF 1215 EF 1216
8W 8W 11W 11W 18W 18W 24W 24W 8W 8W 11W 11W 18W 18W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 2h 1h 3h 1h 3h
EF08N10EBRT EF08N30EBRT EF11N10EBRT EF11N30EBRT EF18N10EBRT EF18N30EBRT EF24N10EBRT EF24N30EBRT EF08N10ABRT EF08N30ABRT EF11N10ABRT EF11N20ABRT EF18N10ABRT EF18N30ABRT EF24N10ABRT EF24N30ABRT
EF 1301 EF 1302 EF 1303 EF 1304 EF 1305 EF 1306 EF 1307 EF 1308 EF 1309 EF 1310 EF 1311 EF 1312 EF 1313 EF 1314 EF 1315 EF 1316
8W 8W 11W 11W 18W 18W 24W 24W 8W 8W 11W 11W 18W 18W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 2h 1h 3h 1h 3h
EF24N10EBRT-H
EF 1317
24W
REST MODE
ENERGY TEST N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
274 274 424 425 326 162 426 427 189 188 292 289 165 163 238 237
ENERGY TEST HIGH FLUX 1h
N/M
521
Ni-MH 6V 4Ah
274 274 424 425 326 162 426 427 189 188 292 289 165 163 238 237
Ni-Cd 6V 1,3Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
SPY SYSTEM EF08N10EBRC EF08N30EBRC EF11N10EBRC EF11N30EBRC EF18N10EBRC EF18N30EBRC EF24N10EBRC EF24N30EBRC EF08N10ABRC EF08N30ABRC EF11N10ABRC EF11N20ABRC EF18N10ABRC EF18N30ABRC EF24N10ABRC EF24N30ABRC
EF 1501 EF 1502 EF 1503 EF 1504 EF 1505 EF 1506 EF 1507 EF 1508 EF 1509 EF 1510 EF 1511 EF 1512 EF 1513 EF 1514 EF 1515 EF 1516
8W 8W 11W 11W 18W 18W 24W 24W 8W 8W 11W 11W 18W 18W 24W 24W
EF24N10EBRC-H
EF 1517
24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 2h 1h 3h 1h 3h
N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
311 313 402 399 269 269 445 445
SPY SYSTEM HIGH FLUX 1h
N/M
521
Ni-MH 6V 4Ah
CENTRAL BATTERY EF08000IBS EF11000IBS EF18000IBS EF24000IBS
EF 1901 EF 1902 EF 1903 EF 1904
8W 11W 18W 24W
EF08000IBS-SC EF11000IBS-SC EF18000IBS-SC EF24000IBS-SC
EF 2001 EF 2002 EF 2003 EF 2004
8W 11W 18W 24W
L L L L
361 605 393 616
L L L L
361 605 393 616
SPY CENTER
130
130130
FLUORESCENT EMERGENCY LUMINAIRES
Evolution Flu ORDER CODE
SHORT CODE
LAMP
DURATION
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
N/M N/M N/M N/M N/M N/M N/M
80 80 173 171 113 92 228
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 0,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,3Ah
N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
210 211 461 276 205 162 321 205 189 188 292 289 165 163 238 237
354 356 438 435 286 284 489 489
Ni-Cd 6V 1,3Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
311 313 402 399 269 269 445 445
Ni-Cd 6V 1,3Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
IP 65 INHIBIT EU08N10EBI EU08N30EBI EU11N10EBI EU11N30EBI EU18N10EBI EU18N30EBI EU24N10EBI
EU 1101 EU 1102 EU 1103 EU 1104 EU 1105 EU 1106 EU 1107
8W 8W 11W 11W 18W 18W 24W
1h 3h 1h 3h 1h 3h 1h
EU08N10EBR EU08N30EBR EU11N10EBR EU11N30EBR EU18N10EBR EU18N30EBR EU24N10EBR EU24N30EBR EU08N10ABR EU08N30ABR EU11N10ABR EU11N20ABR EU18N10ABR EU18N30ABR EU24N10ABR EU24N30ABR
EU 1201 EU 1202 EU 1203 EU 1204 EU 1205 EU 1206 EU 1207 EU 1208 EU 1209 EU 1210 EU 1211 EU 1212 EU 1213 EU 1214 EU 1215 EU 1216
8W 8W 11W 11W 18W 18W 24W 24W 8W 8W 11W 11W 18W 18W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 2h 1h 3h 1h 3h
EU08N10EBRT EU08N30EBRT EU11N10EBRT EU11N30EBRT EU18N10EBRT EU18N30EBRT EU24N10EBRT EU24N30EBRT EU08N10ABRT EU08N30ABRT EU11N10ABRT EU11N20ABRT EU18N10ABRT EU18N30ABRT EU24N10ABRT EU24N30ABRT
EU 1301 EU 1302 EU 1303 EU 1304 EU 1305 EU 1306 EU 1307 EU 1308 EU 1309 EU 1310 EU 1311 EU 1312 EU 1313 EU 1314 EU 1315 EU 1316
8W 8W 11W 11W 18W 18W 24W 24W 8W 8W 11W 11W 18W 18W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 2h 1h 3h 1h 3h
EU24N10EBRT-HH
EU 1317
24W
REST MODE
ENERGY TEST N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
274 274 424 425 326 162 426 427 189 188 292 289 165 163 238 237
ENERGY TEST HIGH FLUX 1h
N/M
521
Ni-MH 6V 4Ah
274 274 424 425 326 162 426 427 189 188 292 289 165 163 238 237
Ni-Cd 6V 1,3Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
SPY SYSTEM EU08N10EBRC EU08N30EBRC EU11N10EBRC EU11N30EBRC EU18N10EBRC EU18N30EBRC EU24N10EBRC EU24N30EBRC EU08N10ABRC EU08N30ABRC EU11N10ABRC EU11N20ABRC EU18N10ABRC EU18N30ABRC EU24N10ABRC EU24N30ABRC
EU 1501 EU 1502 EU 1503 EU 1504 EU 1505 EU 1506 EU 1507 EU 1508 EU 1509 EU 1510 EU 1511 EU 1512 EU 1513 EU 1514 EU 1515 EU 1516
8W 8W 11W 11W 18W 18W 24W 24W 8W 8W 11W 11W 18W 18W 24W 24W
EU24N10EBRC-HH
EU 1517
24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 2h 1h 3h 1h 3h
N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M
311 313 402 399 269 269 445 445
SPY SYSTEM HIGH FLUX 1h
N/M
521
Ni-MH 6V 4Ah
CENTRAL BATTERY EU08000IBS EU11000IBS EU18000IBS EU24000IBS
EU 1901 EU 1902 EU 1903 EU 1904
8W 11W 18W 24W
EU08000IBS-SC EU11000IBS-SC EU18000IBS-SC EU24000IBS-SC
EU 2001 EU 2002 EU 2003 EU 2004
8W 11W 18W 24W
L L L L
361 605 393 616
L L L L
361 605 393 616
SPY CENTER
The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it. The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
131
132132
FLUORESCENT EMERGENCY LUMINAIRES
Step
Also high flux
STEP is a versatile, economic, functional product. Its appearance makes it appreciated by the end user, but above all it is the operators who appreciate it, both for its wide range as well as the reduction in installation time, which drastically lowers the final installation costs.
IDEAL FOR LARGE INDOOR SETTINGS (medical surgeries, shops, schools, gyms, homes, hotels) STANDARD DECORATIVE FRAME ON THE ENTIRE RANGE D
INSTALLATION: WALL-MOUNTED, FLAG STYLE, CEILING AND RECESSED
C
HIGH FLUX TO 700 LUMEN WITH CHROME-PLATED REFLECTOR
A
MOVIE VERSION FOR CINEMAS AND THEATRES B
IP40 A=337 mm B=155 mm C=53 mm D=32 mm
132
IP42
IK07
ï&#x20AC;&#x192; documentation@linergy.it |
PACK
12
technical support 334 1133875
132132
FLUORESCENT EMERGENCY LUMINAIRES
Step QUICK COUPLING The bottom of the ceiling light is set-up for fixing to common boxes used in the electric plants. In addition to knockout rear entrances, three lateral entrances x 16 mm tubes are envisioned. The bottom houses the terminal board for the electric connections and the luminaire body is engaged with a simple snap positioning movement.
Photometric diagrams Range Angles
6W Range Angles
Standard decorative frame on the entire range
8W Range Angles
Protection rating IP40 - IP42 - IK07 Available in versions 6, 8, 11, 18 and 24 W The fixtures with 12 hours recharge time guarantee 2 hours of duration
11 W Range Angles
Can also be installed onto surfaces that are normally flammable Power supply: 230 Vac 50-60 Hz Compliant with European standards EN 60598-1, EN 60598-2-22
18 W Range Angles
24 W
133
134134
FLUORESCENT EMERGENCY LUMINAIRES
Step ACCESSORIES
ELECTRIC CONNECTIONS
ST KT CGE Plasterboard and false ceiling fastening kit Kit for fixing the ceiling light on the plasterboard walls and false ceiling. COMMANDER Controller for the remote management of rest mode Commander manages the rest status and carries out tests on the luminaire. On self-test models it allows for centralized control of the self-diagnosis functions. RTCA16 Tube/conduit fitting Practical fitting for use of tube measuring 16 mm for the entrance of cables towards the ceiling light. Dimensions (mm): internal 17.5 x 6.5 max external 20 x 10, h 32 INC M ST Wall box for recessed installation Dimensions (mm): internal 323.7 x 142.2 max external 331.7 x 164.2
B A
230~ SE
230~ SE
230~ SA
COMMANDER
B A COMMANDER
N/M Models
M Models
Pictograms See the “Accessories and spare parts” section on page 154. Visual range with pictogram = 26 m.
GRIG04 Protective grating Made in galvanized metal for complete protection of the luminaire body against accidental blows or acts of vandalism.
STIS01
CR KT BLINDO Busway accessory Accessory that allows hook up to the busbar.
Spare lamp 24W spare fluorescent lamp code: A131
STIS02
STIS08
ST KT SEG Signalling kit With this kit, the Step can be used like a signalling luminaire in compliance with EN 1838 Standard. See “Signalling Luminaires” sec. on p. 102. Kit of pictograms supplied as standard. SM KT SUP Kit for flag style fastening Bracket for fixing the ceiling light in flag style. KIT 45 GRADI With this bracket, the luminaire can be installed with an inclination of 45° ST KT INC-PL Flush-wall recess kit Excellent flush-wall effect with plastic recess kit. Dimensions (mm): 38 x 19
134
ORDER CODE
SHORT CODE
DESCRIPTION
CRKTBLINDO GRIG04 INCMST RTCA16 SMKTSUP STKTCGE STKTINC-PL STKTSEG KIT45GRADI STIS01 STIS02 STIS08 CORNST COMMANDER
A005 A015 A024 A044 A047 A048 A049 A050 A092 A177 A178 A179 A234 CN0001
BUSBAR KIT PROTECTIVE GRATING WALL BOX RECESSED INSTALLATION STEP IP65 CONNECTOR D=16MM KIT FOR FLAG-STYLE FASTENING PLASTERBOARD AND DROPPED-CEILING FASTENING KIT STEP FLUSH-WALL INTEGRATING KIT SIGNALING KIT STEP CLASP FOR FIXING AT 45 DEGREES PICTOGRAM FOR STEP ARROW LEFT PICTOGRAM FOR STEP ARROW RIGHT PICTOGRAM FOR STEP ARROW DOWN AESTHETIC FRAME FOR STEP CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
PACK 80 10 50 1 10 20 1 10 10 1 1 1 1 1
134134
FLUORESCENT EMERGENCY LUMINAIRES
Step ORDER CODE
SHORT CODE
LAMP
DURATION
ST06N10EBI ST06N30EBI ST08N10EBI ST08N30EBI ST11N10EBI ST11N30EBI ST18N10EBI ST18N30EBI ST24N10EBI
ST 1101 ST 1102 ST 1103 ST 1104 ST 1105 ST 1106 ST 1107 ST 1108 ST 1109
6W 6W 8W 8W 11W 11W 18W 18W 24W
1h 3h 1h 3h 1h 3h 1h 3h 1h
ST06N10EBR ST06N30EBR ST08N10EBR ST08N30EBR ST11N10EBR ST11N30EBR ST18N10EBR ST18N30EBR ST24N10EBR ST24N30EBR ST06N10ABR ST06N30ABR ST08N10ABR ST08N30ABR ST11N10ABR ST11N20ABR ST18N10ABR ST18N30ABR ST24N10ABR ST24N30ABR
ST 1201 ST 1202 ST 1203 ST 1204 ST 1205 ST 1206 ST 1207 ST 1208 ST 1209 ST 1210 ST 1211 ST 1212 ST 1213 ST 1214 ST 1215 ST 1216 ST 1217 ST 1218 ST 1219 ST 1220
6W 6W 8W 8W 11W 11W 18W 18W 24W 24W 6W 6W 8W 8W 11W 11W 18W 18W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 2h 1h 3h 1h 3h
ST06N10EBR-H ST06N30EBR-H ST08N10EBR-H ST08N30EBR-H ST11N10EBR-H ST11N30EBR-H ST18N10EBR-H ST18N30EBR-H ST24N10EBR-H ST24N30EBR-H ST06N10ABR-H ST06N30ABR-H ST08N10ABR-H ST08N30ABR-H ST11N10ABR-H ST11N20ABR-H ST18N10ABR-H ST18N30ABR-H ST24N10ABR-H ST24N30ABR-H
ST 1221 ST 1222 ST 1223 ST 1224 ST 1225 ST 1226 ST 1227 ST 1228 ST 1229 ST 1230 ST 1231 ST 1232 ST 1233 ST 1234 ST 1235 ST 1236 ST 1237 ST 1238 ST 1239 ST 1240
6W 6W 8W 8W 11W 11W 18W 18W 24W 24W 6W 6W 8W 8W 11W 11W 18W 18W 24W 24W
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
N/M N/M N/M N/M N/M N/M N/M N/M N/M
89 71 108 108 176 176 212 176 302
Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 0,6Ah Ni-Cd 6V 1,8Ah Ni-Cd 6V 0,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,3Ah
N/M N/M N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M M M
107 84 150 146 211 232 212 176 312 294 137 114 153 154 267 254 167 191 284 308
199 179 311 313 402 399 269 269 445 445
Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
215 193 354 356 438 435 286 284 489 489
Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
INHIBIT
REST MODE
REST MODE HIGH FLUX 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 2h 1h 3h 1h 3h
N/M N/M N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M M M
177 197 268 328 338 265 321 278 465 394 148 123 175 176 292 276 178 212 312 339
135
136136
FLUORESCENT EMERGENCY LUMINAIRES
Step ORDER CODE
SHORT CODE
LAMP
DURATION
ST06N10EBRT ST06N30EBRT ST08N10EBRT ST08N30EBRT ST11N10EBRT ST11N30EBRT ST18N10EBRT ST18N30EBRT ST24N10EBRT ST24N30EBRT ST06N10ABRT ST06N30ABRT ST08N10ABRT ST08N30ABRT ST11N10ABRT ST11N20ABRT ST18N10ABRT ST18N30ABRT ST24N10ABRT ST24N30ABRT
ST 1301 ST 1302 ST 1303 ST 1304 ST 1305 ST 1306 ST 1307 ST 1308 ST 1309 ST 1310 ST 1311 ST 1312 ST 1313 ST 1314 ST 1315 ST 1316 ST 1317 ST 1318 ST 1319 ST 1320
6W 6W 8W 8W 11W 11W 18W 18W 24W 24W 6W 6W 8W 8W 11W 11W 18W 18W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 2h 1h 3h 1h 3h
ST06N10EBRT-H ST06N30EBRT-H ST08N10EBRT-H ST08N30EBRT-H ST11N10EBRT-H ST11N30EBRT-H ST18N10EBRT-H ST18N30EBRT-H ST24N10EBRT-H ST24N10EBRT-HH ST24N30EBRT-H ST06N10ABRT-H ST06N30ABRT-H ST08N10ABRT-H ST08N30ABRT-H ST11N10ABRT-H ST11N20ABRT-H ST18N10ABRT-H ST18N30ABRT-H ST24N10ABRT-H ST24N30ABRT-H
ST 1321 ST 1322 ST 1323 ST 1324 ST 1325 ST 1326 ST 1327 ST 1328 ST 1329 ST 1330 ST 1331 ST 1332 ST 1333 ST 1334 ST 1335 ST 1336 ST 1337 ST 1338 ST 1339 ST 1340 ST 1341
6W 6W 8W 8W 11W 11W 18W 18W 24W 24W 24W 6W 6W 8W 8W 11W 11W 18W 18W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 1h 3h 1h 3h 1h 3h 1h 2h 1h 3h 1h 3h
ST06N10EBRC ST06N30EBRC ST08N10EBRC ST08N30EBRC ST11N10EBRC ST11N30EBRC ST18N10EBRC ST18N30EBRC ST24N10EBRC ST24N30EBRC ST06N10ABRC ST06N30ABRC ST08N10ABRC ST08N30ABRC ST11N10ABRC ST11N20ABRC ST18N10ABRC ST18N30ABRC ST24N10ABRC ST24N30ABRC
ST 1501 ST 1502 ST 1503 ST 1504 ST 1505 ST 1506 ST 1507 ST 1508 ST 1509 ST 1510 ST 1511 ST 1512 ST 1513 ST 1514 ST 1515 ST 1516 ST 1517 ST 1518 ST 1519 ST 1520
6W 6W 8W 8W 11W 11W 18W 18W 24W 24W 6W 6W 8W 8W 11W 11W 18W 18W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 3h 1h 2h 1h 3h 1h 3h
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
ENERGY TEST N/M N/M N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M M M
107 84 150 146 211 232 212 176 312 294 137 114 153 154 267 254 167 191 284 308
199 179 311 313 402 399 269 269 445 445
Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
215 193 354 356 438 435 286 284 489 489
Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
199 179 311 313 402 399 269 269 445 445
Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
ENERGY TEST HIGH FLUX N/M N/M N/M N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M M M
177 197 268 328 338 265 321 278 465 700 394 148 123 175 176 292 276 178 212 312 339
SPY SYSTEM
136
N/M N/M N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M M M
107 84 150 146 211 232 212 176 312 294 137 114 153 154 267 254 167 191 284 308
136136
FLUORESCENT EMERGENCY LUMINAIRES
Step ORDER CODE
SHORT CODE
LAMP
DURATION
ST06N10EBRC-H ST06N30EBRC-H ST08N10EBRC-H ST08N30EBRC-H ST11N10EBRC-H ST11N30EBRC-H ST18N10EBRC-H ST18N30EBRC-H ST24N10EBRC-H ST24N10EBRC-HH ST24N30EBRC-H ST06N10ABRC-H ST06N30ABRC-H ST08N10ABRC-H ST08N30ABRC-H ST11N10ABRC-H ST11N20ABRC-H ST18N10ABRC-H ST18N30ABRC-H ST24N10ABRC-H ST24N30ABRC-H
ST 1521 ST 1522 ST 1523 ST 1524 ST 1525 ST 1526 ST 1527 ST 1528 ST 1529 ST 1530 ST 1531 ST 1532 ST 1533 ST 1534 ST 1535 ST 1536 ST 1537 ST 1538 ST 1539 ST 1540 ST 1541
6W 6W 8W 8W 11W 11W 18W 18W 24W 24W 24W 6W 6W 8W 8W 11W 11W 18W 18W 24W 24W
1h 3h 1h 3h 1h 3h 1h 3h 1h 1h 3h 1h 3h 1h 3h 1h 2h 1h 3h 1h 3h
ST06N10MBR ST06N30MBR ST08N10MBR ST08N30MBR ST11N10MBR ST11N30MBR ST18N10MBR ST18N30MBR
ST 1701 ST 1702 ST 1703 ST 1704 ST 1705 ST 1706 ST 1707 ST 1708
6W 6W 8W 8W 11W 11W 18W 18W
1h 3h 1h 3h 1h 3h 1h 3h
ST06000IBS ST08000IBS ST11000IBS ST18000IBS ST24000IBS
ST 1901 ST 1902 ST 1903 ST 1904 ST 1905
6W 8W 11W 18W 24W
ST06000IBS-SC ST08000IBS-SC ST11000IBS-SC ST18000IBS-SC ST24000IBS-SC
ST 2001 ST 2002 ST 2003 ST 2004 ST 2005
6W 8W 11W 18W 24W
TYPE
AVERAGE FLUX N/M (lm)
FLUX M (lm)
BATTERY
SPY SYSTEM HIGH FLUX N/M N/M N/M N/M N/M N/M N/M N/M N/M N/M N/M M M M M M M M M M M
177 197 268 328 338 265 321 278 465 700 394 148 123 175 176 292 276 178 212 312 339
215 193 354 356 438 435 286 284 489 489
Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah Ni-Cd 6V 2,5Ah Ni-MH 6V 4Ah Ni-MH 6V 4Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 2,8Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,8Ah Ni-MH 6V 4Ah
MOVIE MOVIE MOVIE MOVIE MOVIE MOVIE MOVIE MOVIE
107 84 150 146 211 232 212 176
6 6 6 6 6 6 6 6
Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 0,8Ah Ni-Cd 6V 2,5Ah Ni-Cd 6V 1,3Ah Ni-MH 6V 3,3Ah Ni-Cd 6V 1,3Ah Ni-Cd 6V 2,5Ah
MOVIE
CENTRAL BATTERY L L L L L
199 311 402 269 445
L L L L L
199 311 402 269 445
SPY CENTER
The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture. Tables with installation distances available at www.linergy.it. The synchronization procedure for the function and duration tests of Linergy Energy test fixtures is on page 39
137
138138
FLUORESCENT EMERGENCY LUMINAIRES
Fox
The small size and pleasant design make FOX suitable for any setting.
IDEAL FOR SMALL SETTINGS (LIFTS, SHOPS, OFFICES, HOMES, HOTELS) INSTALLATION: WALL-MOUNTED, FLAG STYLE, CEILING AND RECESSED PROTECTION RATING IP40 6W FLUORESCENT TUBE CAN ALSO BE INSTALLED ONTO SURFACES THAT ARE NORMALLY FLAMMABLE
C
POWER SUPPLY: 230 VAC 50-60 Hz
A
BATTERY RECHARGING TIME: 12h - 24h
B
COMPLIANT WITH EUROPEAN STANDARDS EN 60598-1, EN 60598-2-22
IP40 A=260 mm B=110 mm C=46 mm
138
ï&#x20AC;&#x192; documentation@linergy.it |
PACK
24
technical support 334 1133875
138138
FLUORESCENT EMERGENCY LUMINAIRES
Fox ELECTRIC CONNECTIONS
ACCESSORIES
The ceiling lights have terminals for inhibition of the emergency. For compliant installation, the switch that inhibits the emergency must be positioned in a way that it can only be accessed by authorised staff. L
Switch for inhibition or jumper
A
B
INC M FX Wall box for recessed installation Dimensions (mm): internal 250 x 102 max external 268 x 138 GRIG03 Protective grating Made in galvanized metal for complete protection of the luminaire body against accidental blows or acts of vandalism.
N
FX KT SEG Signalling kit With this kit, the Fox can be used like a signalling luminaire in compliance with EN 1838 Standard. See “Signalling Luminaires” sec. on p. 102. Kit of pictograms supplied as standard.
230V~ S.E.
FX KT CGE Plasterboard and false ceiling fastening kit Kit for fixing the ceiling light on the plasterboard walls and false ceiling.
QUICK COUPLING The bottom of the ceiling light is set-up for fixing to common boxes used in the electric plants and houses the circuit board with its connections. The luminaire body is engaged with a simple snap positioning movement.
SM KT SUP Kit for flag style fastening Bracket for fixing the ceiling light in flag style. KIT 45 GRADI With this bracket, the luminaire can be installed with an inclination of 45°
Photometric diagram
ORDER CODE
SHORT CODE
DESCRIPTION
FXKTCGE FXKTSEG GRIG03 INCMFX SMKTSUP KIT45GRADI FXIS01 FXIS02 FXIS08
A011 A012 A014 A021 A047 A092 A158 A159 A160
PLASTERBOARD AND DROPPED-CEILING FASTENING KIT FOX SIGNALING KIT FOX PROTECTIVE GRATING WALL BOX RECESSED INSTALLATION FOX KIT FOR FLAG-STYLE FASTENING CLASP FOR FIXING AT 45 DEGREES PICTOGRAMS FOR FOX L PICTOGRAMS FOR FOX R PICTOGRAMS FOR FOX LW
PACK 20 10 10 50 10 10 1 1 1
Range Angles
Pictograms See the “Accessories and spare parts” section on page 154. Visual range with pictogram = 19 m.
6W
FXIS01
ORDER CODE
SHORT CODE
LAMP
DURATION
FX06N10EBI-L FX06N30EBI-L
FX 1101 FX 1102
6W 6W
1h 3h
FXIS02
TYPE
AVERAGE FLUX N/M (lm)
N/M N/M
75 75
FXIS08
FLUX M (lm)
BATTERY
INHIBIT Ni-Cd 6V 1,3Ah Ni-MH 6V 2,8Ah
Tables with installation distances available at www.linergy.it.
139
140140
FLUORESCENT EMERGENCY LUMINAIRES
Seven Plus
TM
Recessed on box 506
SEVEN PLUS is particularly suitable for residential applications. Recessed into the ordinary boxes of the 6-place box electrical system, it is aesthetically finished with plates of the most popular common ranges on the market.
C A
B
A=188 mm B=71 mm C=54 mm
COMPATIBLE WITH THE LATEST PLATES OF THE MOST COMMON CIVIL RANGE IDEAL FOR SMALL SETTINGS
ACCESSORIES
CAN BE USED IN PLACES OF PUBLIC EVENTS AS A MARKER ON THE STAIRS AND AS AN OUTDOOR LIGHT WITH RELEVANT IP55 PLATE
SV PL55-N / SV PL55-M Kit IP55 The IP55 kit comprises the frame SVTL03, the diffuser, the grid and the seal. SVPL-B / SVPL-G White or grey colored finishing plate.
IP40 ï&#x20AC;&#x192; documentation@linergy.it |
140
PACK
12
technical support 334 1133875
140140
FLUORESCENT EMERGENCY LUMINAIRES
Seven Plus Installation from any recess box with 6-places (506) Compatible with the finishing plates of the most popular civil range Protection rating IP40 4W fluorescent tube High luminous efficacy chromed reflector Power supply: 230 Vac 50-60 Hz Maximum battery recharging time: 24 h Possibility to inhibit switch-on with external switch Compliant with European standards EN 60598-1, EN 60598-2-22
Photometric diagram Range Angles
ORDER CODE
SHORT CODE
DESCRIPTION
SVTL01 SVTL02 SVTL03 SVTL04 SVTL05 SVPL55-N SVPL55-M SVPL-G SVPL-B
A051 A052 A053 A054 A055 A067 A078 A079 A094
ADAPTING FRAMEWORKS - AVE, VIMAR PLATES ADAPTING FRAMEWORKS - BTICINO MASTER PLATES ADAPTING FRAMEWORKS - SEVEN ADAPTING FRAMEWORKS - SEVEN ADAPTING FRAMEWORKS - BTICINO LIVING AIR KIT IP55 FINISH PLATE BLACK SEVEN KIT IP55 FINISH PLATE METALLIC SEVEN CHARCOALGRAY FINISH PLATE SEVEN WHITE FINISH PLATE SEVEN
PACK 1 1 1 1 1 1 1 1 1
ADAPTER FRAMES Frames 01 and 02 are available on request.
Frames 03 and 04 are supplied as per standard.
Frame 01
VIMAR IDEA CLASSICA - IDEA RONDÒ PLANA - EIKON AVE NOIR - BANQUISE - ZAMA 45 - YES 45 - RAL 45 - SISTEMA 44
Frame 03
VIMAR EIKON - EIKON EVO - ARKÉ PLANA B-TICINO MATIX
Frame 02
B-TICINO AXOLUTE - LIVING CLASSIC LIVING INTERNATIONAL - LIGHT - LIGHT TECH - MATIX GEWISS CHORUS LUX - CHORUS ONE CHORUS GEO MASTER MODO + ACCESSORY FOR 7 MODULES
Frame 04
VIMAR IDEA B-TICINO AXOLUTE - LIVING LIGHT
Frame 05 must be ordered separately.
Patent pending
B-TICINO LIVING LIGHT AIR
Frame 05
ORDER CODE
SHORT CODE
LAMP
DURATION
SF04N10EBI
SF 1101
4W
1h
TYPE
AVERAGE FLUX N/M (lm)
N/M
46
MOVIE
46
FLUX M (lm)
BATTERY
INHIBIT Ni-Cd 6V 0,4Ah
MOVIE SF04N10MBI
SF 1701
4W
1h
6
Ni-Cd 6V 0,4Ah
CENTRAL BATTERY SF04000IBS
SF 1901
4W
L
120
The products in the Central Battery range are compatible with the Spy Center system, but they do not have control of the individual fixture.
141
142142
EMERGENCY KIT
Send an e-mail to documentation@linergy.it and you will receive a link to download the constantly updated technical-sales material. NOTE Specify in object: â&#x20AC;&#x153;Documentationâ&#x20AC;?
142142
EMERGENCY KIT
WHAT ARE THEY? The emergency kits allow normal ceiling lights to be used even for emergency lighting. In this way, we have a unique light source with double function, without seeing the emergency system. WHY USE THEM? The kit is especially important in environments of particular architectural value, where the traditional emergency system could upset the beauty of the environment. FUNCTIONING TYPE The emergency kits are available in N/M versions (nonmaintained) and M versions (maintained). Normally the latter version is used because in conjunction with the ceiling light where they are installed, they can provide normal and emergency lighting. LUMINAIRE MAXIMUM POWER The emergency kits are characterised by the maximum power of the tube that can be installed: therefore, there will be 58 W kits that can power a 58 W fluorescent tube to maximum and, obviously, tubes with smaller wattage.
DURATION Normally, the duration of the emergency kits are supplied for the maximum powerable luminaire. For example, with the 58W models, the stated duration of 1 h is valid for a 58W luminaire. The autonomy increases if the luminaires have lower power. CONNECTIONS The emergency kits lend themselves to different kind of connections: they can be paired with ceiling lights which have a traditional reactor and starter, or with models which have an electronic ballast. REST MODE Also for the control kit, it is important to be able to manage rest mode whenever it is necessary to inhibit emergency system operation. In this case, using the appropriate remote control device, the rest mode can be managed correctly. The luminaires remain inhibited, but they are active and selfrestorable in the event of a blackout. NOTE: the fluorescent tubes that are compatible with Linergy Euroinverter and Fastinverter L models are those with 4 pins.
Availability of certified wiring diagrams with the best marks of electronic ballasts: support@linergy.it
143
144144
EMERGENCY KIT
Led Inverter
LOW VOLTAGE compatible with driver with max output. 60 Vdc/2A
HIGH VOLTAGE Compatible with driver with max output. 300 Vdc/2A
for led lighting fixtures Low voltage A
B C
The LED INVERTER can be used together with Led lighting luminaires in which the leds are piloted by commercial supply units with output up to 60Vdc/2A (LOW VOLTAGE) or up to 300 Vdc/2A (HIGH VOLTAGE). By means of a relay, Led piloting is switched from ordinary lighting to emergency lighting.
D E
COMBINED OPERATION - MAINTAINED (IF USED WITH LUMINAIRE DRIVER) AND NOT MAINTAINED
A=174 mm B=41 mm C=27 mm D=135 mm E=Ø 19/27 mm
A
High voltage
COMPATIBLE WITH POWER LED (FROM 1 TO 4W) OR LED STRIPS (FROM 12 OR 24V)
D
INSTANT INTERVENTION TIME IN THE EVENT OF A BLACKOUT
B E
C A=175mm B=27mm C=46mm D=19/27mm E=135mm
144
IP20 documentation@linergy.it |
PACK
16
technical support 334 1133875
144144
EMERGENCY KIT
Led Inverter Quick coupling terminal board
EXAMPLES OF CONNECTION
Lithium Iron Phosphate Li-FePO4 battery: lasts twice as long as traditional Ni-Cd batteries
CONNECTION WITH LED STRIP AND BALLAST AT CONSTANT VOLTAGE (LOW VOLTAGE)
Protection rating IP20
Do not exceed the maximum current of 2A
Power supply: 230 Vac 50-60 Hz
ART. LI04F30ABR
Maximum battery recharging time: 12h
230V ~
1 2 3 4
L N B A
MAX VOUT SELECTOR (J3)
Made in Italy
ELECTRONIC DRIVER FOR LED EMERGENCY LIGHT WITH REST MODE 230Vac - 50Hz BATT. LiFePO4 6.4V 3Ah
0,75 - 1
AUT. 3h
tc=56°C
J3
24V
5 6 7 8
SA 46V
temp. funzionamento/working temp: 0°- 40°C
Operation with LED strips max 30W
Batt.
12V
12h
tens.circuito aperto/open circuit voltage: 60V MAX
58V
xxxxxxxx
Corrente di uscita/Output current 500mA MAX
Compliant with European standards EN 60598-222, EN 61347-1-7
Neg. (-) Pos. (+) Neg. (-) Pos. (+)
DRIVER
230Vac
LED OUT
The Led absorption must be lower than the maximum current supported
Battery recharge and power on Led Prolonged discharge protection device Inhibition option in Rest Mode with the COMMANDER (optional)
+ -
BALLAST MAX 2A-90V
The part of the Led strip that exceeds the maximum current must be connected directly to the driver
CONNECTION WITH LED SPOTLIGHTS AND BALLAST AT CONSTANT CURRENT (HIGH VOLTAGE) Driver Max Vout 300Vdc
OUTPUT IN EMERGENCY In normal conditions (network present) the Leds light up with maximum power, determined by the driver that powers them. In emergency conditions, the Leds light up with reduced power, because they are powered by the Led Inverter.
230V ~
1 2 3 4
SELECT VOUT J6 WHEN LAMP OFF SELEZIONARE J6 A LAMPADA SPENTA
LH04F10ABR
L N
SELF CONTAINED MAINTAINED REST MODE SA
230V~ 50/60Hz BATT. Li-FePO4 6,4V 1,5Ah
Lin Temp.Funzionamento/Working Temp. : da 0°C a +40°C
Lout
Tens.CircuitoAperto/Open Circuit Voltage:300VdcMax
A B
0,75 - 1
IP20
300V
AUT. 1h
200V 200V
Made in Italy
100V
Batt
Connettere la batt d o p o a v e r cablato i led Connect the batt
J6 after the leds
5 6 7 8
are connected BALLAST MAX 2A-300V
LED OUT
The maximum output power of the Led Inverter is 4 W. The output is therefore calculated as follows: OUTPUT (%) = 100 x (4 / MAXIMUM POWER) Example of a 10 W luminaire: Output in emergency mode = 100 x (4 / 10) = 40%
COMMERCIAL LED DRIVER MAX 60V
ORDER CODE
SHORT CODE
DESCRIPTION
COMMANDER
CN0001
CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
PACK
1.5A LED STRIP
LED INVERTER LINERGY
LOW VOLTAGE LED SPOTLIGHTS
4W SUPPLIED ON THE LEDS
LED PANELS
During discharge in emergency mode, 4 W max. are supplied to the leds, therefore the output current decreases with the increase in the number of leds.
COMMERCIAL LED DRIVER MAX 300V LOW VOLTAGE ORDER CODE
SHORT CODE
OUTPUT
LI04F10ABR LI04F30ABR
LI 1201 LI 1202
4W 4W
LI04F10ABRT LI04F30ABRT
LI 1301 LI 1302
LI04F10ABRC LI04F30ABRC
LI 1501 LI 1502
HIGH VOLTAGE DURATION
BATTERY
ORDER CODE
SHORT CODE
OUTPUT
1h 3h
Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
LH04F10ABR LH04F30ABR
LH 1201 LH 1202
4W 4W
1h 3h
Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
LH04F10ABRT LH04F30ABRT
LH 1301 LH 1302
1h 3h
Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
LH04F10ABRC LH04F30ABRC
LH 1501 LH 1502
REST MODE
BATTERY
1h 3h
Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
1h 3h
Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
1h 3h
Li-FePO4 6,4V 1,5Ah Li-FePO4 6,4V 3Ah
ENERGY TEST
SPY SYSTEM 4W 4W
DURATION
REST MODE
ENERGY TEST 4W 4W
1
4W 4W
SPY SYSTEM 4W 4W
Note: The product is factory set to operate with the COMMANDER in the REST MODE mode. For info: support@linergy.it
145
146146
EMERGENCY KIT
Euroinverter
for fluorescent tubes only linear T8 and compact with 4 pins
The EUROINVERTER transforms any source of light with fluorescent tubes into emergency light. Depending on the models and the connections, it is possible to produce maintained or non-maintained emergency lighting. It can be coupled with both starter-operated electro-mechanical ballasts as well as the most modern electronic ballasts with built-in preheating. The reduced-size case is made out of self-extinguishing ABS and allows for practical installation even in the least comfortable situations.
A
B
QUICK COUPLING TERMINAL BOARD C
MAINTAINED OPERATION WITH BALLAST OR NON-MAINTAINED D E
PROTECTION RATING IP20 MAXIMUM BATTERY RECHARGING TIME: 24h
A=170 mm B=41 mm C=35 mm D=212 mm E=Ø 22 mm
FLUORESCENT TUBES 18W-36W-58W T8 COMPLIANT WITH EUROPEAN STANDARDS EN 60598-2-22, EN 61347-1-7
The inverters are also available in industrial packing with 24 pieces (code EI58M-E-C24)
PACK
IP20
24
documentation@linergy.it |
ORDER CODE
SHORT CODE
OUTPUT
EI58SA-E EI58SA-E-C24
EI 1101 EI 1102
T8: 18W(15%)-36W(10%)-58W(7%) T8: 18W(15%)-36W(10%)-58W(7%)
DURATION
technical support 334 1133875 BATTERY
INHIBIT
146
1h 1h
Ni-Cd 6V 1,3Ah Ni-Cd 6V 1,3Ah
146146
EMERGENCY KIT
Euroinverter LAYOUT WITH ELECTRONIC BALLAST HELVAR 2X58 NGN
LAYOUT WITH ELECTRO-MECHANICAL BALLAST Connection layout of the electro-mechanical ballast
H
ob^ qqlob=bibq qolkf`l bib`qolkf`=_^ ii^pq ebi s ^o=OuRU=kdk
G
E
F
D
C
A
Connection layout of the electronic ballast
NERO/_ i ^ ` h ROSSO/o b a
BATT
Batt.
B
B A
230V~ RETE/mltbo
1 2 3 4
EUROINVERTER
Batt. EUROINVERTER
B A
230V~ RETE/m l t b
1 2 3 4 o
EI58SA/E
5 6 7 8 9 10 11
L
G
L A M P 1 F
LAMP1 IN EMERGENZA
Connection layout with ballast plus emergency
E
L
230V~
L
L A M P
sempre accesa con reattore e starter ¥~¦¬~¡¦”“=¯¡¬—=‘~¤¤~«¬=~¦“=«¬~ª¬”ª
H
NERO/_i^`h ROSSO/oba
s
reattore/ballast
Connection layout with electronic ballast plus emergency
BATT
N
5 6 7 8 9 10 11
BATT
N
NERO/_i^`h ROSSO/oba
B A D
C
230V~ L
L A M P 2
N ob^ qqlob=bibqqolkf`l bib`qolkf`=_^ii^pq B
RETE/mltbo
Batt.
1 2 3 4
EUROINVERTER
5 6 7 8 9 10 11
s
L A M P 1*
L A M P 2
N
s
reattore/ballast sempre accesa con reattore, starter e due tubi in serie G«§¤§=¤~=¤~¥¨~“~=N=«¡=~’’”¦“”=¡¦=”¥”ª–”¦²~ ¥~¦¬~¡¦”“=¯¡¬— =‘~¤¤~«¬I=«¬~ª¬”ª=~¦“=¬¯§=¬-‘”«=¡¦=«”ª¡”«§¦¤±=¤~¥¨=N=¬-ª¦«=§¦=“-ª¡¦–=¬—”=”¥”ª–”¦’±
A
LAYOUT WITH OSRAM ELECTRONIC BALLAST 4X18
LAYOUT WITH ELECTRONIC BALLAST PHILIPS HF 2X36 Connection layout of the electro-mechanical ballast
Connection layout of the electronic ballast
1 2
3 4
Connection layout with electronic ballast plus emergency
Connection layout with ballast plus emergency BATT
Battery
230 Vac
L
+
1 2
N
3 4
EUROINVERTER
5 6 7 8 9 10 11
LAMP 1
NERO/_i^`h ROSSO/oba
B
4
LAMP1 IN EMERGENCY
A
230V~ LAMP 2
RETE/mltbo
5
Batt.
1 2 3 4
EUROINVERTER
5 6 7 8 9 10 11
L A M P
230V~ *Osram
ob^ qqlob=bibqqolkf`l bib`qolkf`=_^ii^pq
N
*Osram
N
6
LAMP 4
7
L N
1 2 3 4 5 6 7
L A M P
L
LAMP 3
L
The afore-mentioned layouts refer to code EI58M-E For further connection layouts, visit www.linergy.it, download area.
147
148148
EMERGENCY KIT
Fastinverter L FASTINVERTER L is the technological evolution of traditional emergency kits. They perform innovative services on this typology of product. A height of only 21 mm makes it compatible with almost all the ceiling lights that exist on the market. Complete recharging of the battery is achieved in only 12 hrs, after which the battery recharger positions itself with a minimum maintenance current which visibly slows down natural deterioration of the performance of the battery itself over time.
SMALLER CLEARANCE: HEIGHT 21 mm
for fluorescent tubes only linear T5, T8 and compact with 4 pins
QUICK COUPLING TERMINAL BOARD MAINTAINED OPERATION WITH BALLAST OR NON-MAINTAINED POSSIBILITY OF REMOTE MANAGEMENT OF THE REST MODE USING THE COMMANDER
A
BATTERY RECHARGING TIME: 12h
C
OPERATION OF FLUORESCENT TUBES WITH 4 PINS
B
COMPLIANT WITH EUROPEAN STANDARDS EN 60598-2-22, EN 61347-1-7
D
E
IP20 A=278 mm B=30 mm C=22 mm D=245/298 mm E=Ø 25/32 mm ORDER CODE
SHORT CODE
documentation@linergy.it |
OUTPUT
DURATION
PACK
20
technical support 334 1133875 BATTERY
REST MODE FT35N10ABR
FT 1201
FT35N30ABR
FT 1202
FT80N10ABR
FT 1203
FT80N30ABR
FT 1204
T5: 14W(15%)-21W(17%)-24W(9%)-28W(15%)-35W(15%) T8: 18W(8%) T5: 14W(15%)-21W(17%)-24W(9%)-28W(15%)-35W(15%) T8: 18W(8%) T5: 39W(9%)-49W(11%)-54W(9%)-80W(6%) T8: 36W(7%)-58W(6%) T5: 39W(9%)-49W(11%)-54W(9%)-80W(6%) T8: 36W(7%)-58W(6%)
1h
Ni-Cd 6V 2,5Ah
3h
Ni-Cd 6V 5Ah
1h
Ni-Cd 6V 2,5Ah
3h
Ni-MH 6V 7Ah
1h
Ni-Cd 6V 2,5Ah
3h
Ni-Cd 6V 5Ah
1h
Ni-MH 6V 2,8Ah
3h
Ni-MH 6V 7Ah
1h
Ni-Cd 6V 2,5Ah
3h
Ni-Cd 6V 5Ah
1h
Ni-MH 6V 2,8Ah
3h
Ni-MH 6V 7Ah
ENERGY TEST FT35N10ABRT
FT 1301
FT35N30ABRT
FT 1302
FT80N10ABRT
FT 1303
FT80N30ABRT
FT 1304
FT35N10ABRC
FT 1501
FT35N30ABRC
FT 1502
FT80N10ABRC
FT 1503
FT80N30ABRC
FT 1504
T5: 14W(15%)-21W(17%)-24W(9%)-28W(15%)-35W(15%) T8: 18W(8%) T5: 14W(15%)-21W(17%)-24W(9%)-28W(15%)-35W(15%) T8: 18W(8%) T5: 39W(9%)-49W(11%)-54W(9%)-80W(6%) T8: 36W(7%)-58W(6%) T5: 39W(9%)-49W(11%)-54W(9%)-80W(6%) T8: 36W(7%)-58W(6%)
SPY SYSTEM T5: 14W(15%)-21W(17%)-24W(9%)-28W(15%)-35W(15%) T8: 18W(8%) T5: 14W(15%)-21W(17%)-24W(9%)-28W(15%)-35W(15%) T8: 18W(8%) T5: 39W(9%)-49W(11%)-54W(9%)-80W(6%) T8: 36W(7%)-58W(6%) T5: 39W(9%)-49W(11%)-54W(9%)-80W(6%) T8: 36W(7%)-58W(6%)
Industrial Pack The FastInverters L are available in 24-pieces industrial packs whenever the individual pack is not requested. For the industrial pack add “-C24” to the Model Code. Example: FT35N10ABR-C24 Note: The product is factory set to operate with the COMMANDER in the REST MODE mode. For info: support@linergy.it Note: The synchronization procedure for the function and duration tests of Fastinverter L Energy test is on page 39
148
148148
EMERGENCY KIT
Fastinverter L LAYOUT WITH ELECTRO-MECHANICAL BALLAST
LAYOUT WITH ELECTRONIC BALLAST HELVAR EL 3X18
Connection layout of the electro-mechanical ballast
Connection layout of the electro-mechanical ballast
REATTORE/BALLAST
L
2
1
3
L A M P
s
N
Connection layout with ballast plus emergency
Connection layout with ballast plus emergency LED
Alimentazione
L
N
L
REATTORE/BALLAST
L N Lin Lout B A
FASTINVERTER T5
+ -
7 8 9 10 11 12 13 14
L A M P
N
230V~
1 L 2 N 3 Lin 4 Lout 5 B 6 A
s L 230V~N
FASTINVERTER T5
Batt. ROSSO/oba
1 2 3 4 5 6
7 8 9 10 11 12 13 14
NERO/_i^`h
RETE/POWER 230V
LAMP1
BATT
A fluorescent tube and a ballast
LAMP2
Alimentazione
LAMP3
LAYOUT WITH ELECTRONIC BALLAST OSRAM QTi 1X14
LAYOUT WITH ELECTRONIC BALLAST HELVAR EL 4X18
Connection layout of the electronic ballast
Connection layout of the electronic ballast
1 2 3
4
Osram QTi 1X14W T5
Connection layout with electronic ballast plus emergency
Connection layout with electronic ballast plus emergency LED
Alimentazione N
230V~
LED
L
230V~
^
`
b
i
Batt.
1 L 2 N 3 Lin 4 Lout 5 B 6 A
L 230V~N
FASTINVERTER T5
Batt.
LAMP1
NERO/_
ROSSO/o
a
h
L 230V~N
FASTINVERTER T5
7 8 9 10 11 12 13 14
ROSSO/oba
1 L 2 N 3 Lin 4 Lout 5 B 6 A
NERO/_i^`h
Alimentazione/Power Fastinverter L N
7 8 9 10 11 12 13 14 LAMP1
BATT
BATT
L N
LAMP2
Alimentazione Power Ballast elettronico
Alimentazione/Power Ballast elettronico
LAMP3
LAMP4
The above-mentioned layouts refer to the FASTINVERTER L For further connection layouts, visit www.linergy.it, download area.
ORDER CODE
SHORT CODE
DESCRIPTION
COMMANDER
CN0001
CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
PACK 1
149
150150
EMERGENCY KIT
Fastinverter Alta Resa T8
High output T8: 18W (27%) 36W (21%) 58W (15%)
for fluorescent linear T8 tubes and 4-pin compact tubes
The Fastinverter Alta Resa T8 has high output levels in the emergency mode: 18W - 27% 36W - 21% 58W - 15% A height of only 22 mm makes it compatible with almost all ceiling lights on the market. Complete charging of the battery is achieved in only 12 hours, after which the battery charger positions itself with a minimum maintenance current which slows down the natural deterioration of the battery over time.
SMALL SIZE A
LED FOR INDICATION OF MAINS ON AND BATTERY CHARGE
C
PROTECTION DEVICE AGAINST PROLONGED DISCHARGES
B
E
MAINTAINED OPERATION WITH BALLAST OR NOT-MAINTAINED
D
THE PRODUCT IS FACTORY SET FOR OPERATING WITH THE COMMANDER IN REST MODE COMPLIANT WITH EUROPEAN STANDARDS EN 60598-2-22, EN 61347-1
A=278 mm B=30 mm C=22 mm D=245 mm E=Ø 25 mm
IP20 documentation@linergy.it |
150
PACK
20
technical support 334 1133875
150150
LAYOUT WITH ELECTRONIC BALLAST HELVAR EL 3X18
LAYOUT WITH ELECTRONIC BALLAST OSRAM QTi 1X36
Connection layout of the electro-mechanical ballast
Connection layout of the electronic ballast
2
1
3
Osram QTi 1X36
Connection layout with ballast plus emergency
Connection layout with electronic ballast plus emergency
Alimentazione/Power Fastinverter L N 230V~
N
230V~
` ^
a
h
L 230V~N b
ROSSO/oba
NERO/_i^`h
Batt.
i
L 230V~N
FASTINVERTER T5
1 L 2 N 3 Lin 4 Lout 5 B 6 A
7 8 9 10 11 12 13 14
ROSSO/o
1 L 2 N 3 Lin 4 Lout 5 B 6 A
FASTINVERTER T5
Batt.
7 8 9 10 11 12 13 14
LAMP1
NERO/_
L
LED
LED
Alimentazione
LAMP1 BATT
BATT
L N LAMP2
Alimentazione
Alimentazione/Power Ballast elettronico
LAMP3
The above-mentioned layouts refer to the FASTINVERTER ALTA RESA T8. For further connection layouts, visit www.linergy.it, download area. ORDER CODE
SHORT CODE
DESCRIPTION
COMMANDER
CN0001
CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
PACK
ORDER CODE
SHORT CODE
OUTPUT
FT58N10ABR
FT 1205
T8: 18W(27%)-36W(21%)-58W(15%)
1
DURATION
BATTERY
REST MODE 1h
Ni-MH 6V 3,3Ah
1h
Ni-MH 6V 3,3Ah
1h
Ni-MH 6V 3,3Ah
ENERGY TEST FT58N10ABRT
FT 1305
T8: 18W(27%)-36W(21%)-58W(15%)
SPY SYSTEM FT58N10ABRC
FT 1505
T8: 18W(27%)-36W(21%)-58W(15%)
151
152152
ACCESSORIES AND SPARE PARTS
152
152152
AC C E S S O R I E S A N D S PA R E PA RT S
Commander
Control for remote management of rest mode
If there is no network present, the COMMANDER allows remote control of switch-on and switchoff of the emergency luminaires and also allows to control the load. On return of the network, the possibility of intervention in the case of another blackout automatically restores itself. In this way, the life span of the storage batteries in environments with long downtime periods, can be protected. With the Energy Test models, the test can be controlled remotely. REST MODE MANAGEMENT COMPLIANT WITH STANDARD EN 60598-2-22 MAX NUMBER OF LUMINAIRES THAT CAN BE CONTROLLED: 120 MAXIMUM CONNECTION DISTANCE: 500 m A
INSTALLATION ON DIN GUIDE (4 MODULES) BATTERY INCORPORATED
B
C
A=71 mm B=70,5 mm C=91 mm
WEIGHT 230 g
ORDER CODE
SHORT CODE
DESCRIPTION
COMMANDER
CN 0001
CONTROLLER FOR THE REMOTE MANAGEMENT OF REST MODE
PACK 1
153
154154
AC C E S S O R I E S A N D S PA R E PA RT S
Pictograms Pictograms in conformity with standard UNI EN ISO 7010 Custom pictograms are available on request. Examples of non-standard pictograms (code PITTOGEN): 01
02
08
The pictogram code is established by placing the number that indicates the pictogram type after the four characters indicating the luminaire model.
D.LGS 81/08
SAFE AREA
EXIT
STAIRWAY EXIT
GENTS-LADIES WC
EXIT
USCITA DI SICUREZZA SAFETY EXIT
ALLARME INCENDIO FIRE ALARM
The management of feasibility and the type coupled to the various sizes, must be performed directly with the Linergy technical dept.
154
ORDER CODE
SHORT CODE
DESCRIPTION
BG60IS01 BG60IS02 BG60IS08-A BG60IS08-B BG80IS01 BG80IS02 BG80IS08-A BG80IS08-B CEIS01 CEIS02 CEIS08 CRIS01 CRIS02 CRIS08 ELIS01 ELIS02 ELIS02 ELIS08 FXIS01 FXIS02 FXIS08 KITASISO-22 KITASISO-32 KITLVISO KITLVISO-22 KITQU26ISO KITQU44ISO KITSWISO LDIS01 LDIS02 LDIS08 PRIS01 PRIS02 PRIS08 STIS01 STIS02 STIS08 TKIS01 TKIS02 TKIS08
A136 A137 A139 A140 A141 A142 A144 A145 A146 A147 A148 A149 A150 A151 A155 A156 A156 A157 A158 A159 A160 A161 A162 A163 A164 A165 A166 A167 A168 A169 A170 A171 A172 A173 A177 A178 A179 A180 A181 A182
PICTOGRAM FOR BIG ONE 60M IS01 PICTOGRAM FOR BIG ONE 60M IS02 PICTOGRAM FOR BIG ONE 60M IS08 PICTOGRAM FOR BIG ONE 60M IS08 PICTOGRAM FOR BIG ONE 80M IS01 PICTOGRAM FOR BIG ONE 80M IS02 PICTOGRAM FOR BIG ONE 80M IS08 PICTOGRAM FOR BIG ONE 80M IS08 PICTOGRAM FOR CRISTAL EVO ARROW LEFT PICTOGRAM FOR CRISTAL EVO ARROW RIGHT PICTOGRAM FOR CRISTAL EVO ARROW DOWN PICTOGRAM FOR CRISTAL ARROW LEFT PICTOGRAM FOR CRISTAL ARROW RIGHT PICTOGRAM FOR CRISTAL ARROW DOWN PICTOGRAMS FOR EVOLUTION L PICTOGRAMS FOR EVOLUTION R PICTOGRAMS FOR EVOLUTION R PICTOGRAMS FOR EVOLUTION LW PICTOGRAMS FOR FOX L PICTOGRAMS FOR FOX R PICTOGRAMS FOR FOX LW PICTOGRAMS FOR ASTRA 22M PICTOGRAMS FOR ASTRA 32M PICTOGRAMS FOR LYRA EVO PICTOGRAMS FOR LYRA EVO 22M PICTOGRAMS FOR QUBE PICTOGRAMS FOR QUBE PICTOGRAMS FOR SWING PICTOGRAMS FOR LEDY L PICTOGRAMS FOR LEDY R PICTOGRAMS FOR LEDY LW PICTOGRAM FOR PRODIGY ARROW LEFT PICTOGRAM FOR PRODIGY ARROW RIGHT PICTOGRAM FOR PRODIGY ARROW DOWN PICTOGRAM FOR STEP ARROW LEFT PICTOGRAM FOR STEP ARROW RIGHT PICTOGRAM FOR STEP ARROW DOWN PICTOGRAMS FOR ICETEK - LEFT PICTOGRAMS FOR ICETEK - RIGHT PICTOGRAMS FOR ICETEK - DOWN
PACK. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
154154
AC C E S S O R I E S A N D S PA R E PA RT S
Batteries CODE
BATTERY
DESCRIPTION
B 004 B 005 B 012 B 021 B 032 B 033 B 036 B 038 B 040 B 042 B 043 B 044 B 045 B 046 B 047 B 050 B 052 B 053 B 056 B 057 B 063 B 066 B 072 B 083 B 087 B 101 B 102 B 103 B 104 B 105 B 106
BATLF6V41A518650 BATLF6V43A026650 BATNC6V0A7A2C BATNH6V3A8C55 BATTLI3V71A7 BATTLI3V74A BATTNC4V80A5AA BATTNC4V81A4A BATTNC6V0A8AA BATTNC6V1A3SC BATTNC6V1A3SCF BATTNC6V1A8SC BATTNC6V1A8SCF BATTNC6V5AD BATTNH4V82A0A BATTNH6V2A8SC BATTNH6V4AC BATTNH6V7AD BATTNICD6V0A45 BATTNICD6V0A6 BATTNICD6V2A5 BATTNIMH6V3A3 BATNH3V640MAH BATNC4V81A8SC BATLF3V21A53P BATLF3V20A553P BATLF3V23A03P BATLF3V24A53P BATLF12V83A0 BATLF6V41A53P BATLF6V43A03P
BATTERY LiFePO4 6,4V 1,5AH BATTERY LiFePO4 6,4V 3,0AH BATTERY NICD 6V 0,7AH SIZE 1/2A COMMANDER BATTERY NIMH 6 VOLT 3,8AH 25/245 C HT=55 BATTERY LI-ION 3,7 VOLT 1,7AH 10X34X55 BATTERY LI-PO 3,7 VOLT 4AH 8X47X96 BATTERY NICD 4,8 VOLT 0,5AH 14X28X98 AA Battery NiCd 4,8 Volt 1,4Ah 16,5X33X98 A BATTERY NICD 6V 0,8AH AA BATTERY NICD 6 VOLT 1,3AH D=22 L=212 SC BATTERIY NICD 6V 1,3AH 110X42 SC AFFIAN BATTERY NICD 6 VOLT 1,8AH D=22 L=212 SC BATTERY NICD 6V 1,8AH 110X42 SC BATTERY NICD 6 VOLT 5AH D=32 L=300 D BATTERY NIMH 4,8 VOLT 2AH 16,5X33X98 A BATTERY NIMH 6 VOLT 2,8AH D=22 L=212 SC BATTERY NIMH 6 VOLT 4AH D=25 L=245 C BATTERY NIMH 6 VOLT 7AH D=32 L=300 D BATTERY NICD 6 VOLT 0,45AH D=17 L=111 2/5A BATTERY NICD 6 VOLT 0,6AH D=14 L=240 AA BATTERY NICD 6 VOLT 2,5AH D=25 L=245 C BATTERY NIMH 6 VOLT 3,3AH D=25 L=245 C BATTERY NH 3,6V 40MAH BATTERIA NICD 4,8V 1,8AH SC PER NANOLED BATTERY LIFEPO4 3,2V 1,5AH BATTERY LiFePO4 3,2V 0,55AH SIZE 1450 BATTERY LiFePO4 3,2V 3AH SIZE 18650 BATTERY LIFEPO4 3,2V 4,5AH BATTERY LiFePO4 12,8V 3,0AH BATTERY LiFePO4 6,4V 1,5AH 3P BATTERY LiFePO4 6,4V 3,0AH 3P
PACK 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Fluorescent tubes ORDER CODE
SHORT CODE
DESCRIPTION
LMPNC0112G7 LMPNC0182G11 LMPNC0242G11 LMPNC0242G11C LMPNL004G5 LMPNL006G5 LMPNL008G5
A 127 A 129 A 130 A 131 A 132 A 133 A 134
COMPACT FLUORESCENT LUMINAIRE 11W 2G7 COMPACT FLUORESCENT LUMINAIRE 18W 2G11 COMPACT FLUORESCENT LUMINAIRE 24W 2G11 COMPACT FLUO. LUMINAIRE 24W STEP/EVOLUTION 2G110C LINEAR FLUORESCENT LUMINAIRE 4W G5 LINEAR FLUORESCENT LUMINAIRE 6W G5 LINEAR FLUORESCENT LUMINAIRE 8W G5
PACK 1 1 1 1 1 1 1
155
156156
GENERAL CONDITIONS
SALES ORDER ACCEPTANCE
QUANTITIES - PACKAGING
The orders are subject to the approval of Linergy’s business management staff and are understood to be accepted in accordance with general sales conditions stated herein, without reservation of any kind. Orders received any other way that is different to that stated shall not be accepted. Any waivers must be confirmed in writing by Linergy. Linergy reserves the right to fulfil orders only partially as well as void them, also for any remaining parts of orders, if the status of the buyer changes. For that not provided for by the general sales conditions, the laws of the Italian Civil Code on that matter shall apply.
The quantities ordered are subject to variations in relation to availability and the standard packaging for products. RETURNS Returned goods are not accepted unless pre-emptively authorized in writing by Linergy’s business management staff. Shipping costs for any return are to be paid by the customer. Linergy will provide for the accrediting or the rejection of returns only after having checked the condition of returned goods, reserving the right to the recovery of the expenses and costs incurred for the restoration of the products.
DELIVERY AND SHIPPING OF GOODS PAYMENTS The terms of delivery are always approximate and are normally calculated in working days. Linergy shall with the utmost diligence try to respect the terms indicated on the order, however the buyer may not attempt to cancel the order or be compensated if these terms are not respected. Any modifications of the terms of delivery requested by the buyer must be accepted in writing by Linergy. Freight costs shall be paid by the buyer. The goods always travel at the risk and danger of the buyer even if they are dispatched free port. In the event of theft or tampering, the buyer must contact to the carrier; any dispute relative to the number and status of the parcels shall be rejected if it is not reported to the carrier and if Linergy is not notified in writing within 8 days of the dispatching of the goods themselves. PRICES The prices are always understood to be ex works Linergy unless there is a different written agreement. The proposal and acceptance of orders are always understood to be in accordance with the prices and conditions which apply at the moment of the delivery of the goods. The prices are understood to be net of VAT and other potential fiscal burdens.
156
The goods are sold with the explicit agreement of reserved ownership in favour of Linergy up until their complete payment. Payments are valid only if they are made at Linergy’s registered premises and in accordance with the conditions of the invoice. Any delay in payment, even if partial, shall give Linergy the right to charge interest at the official discount rate increased by 5 percentage points. Any delay in payment authorizes Linergy to suspend the existing orders and supplies. DISPUTES The competent jurisdiction for any disputes is exclusively the Law Court of Ascoli Piceno, with no possibility of any changes. All contracts are governed by Italian law.
156156
GENERAL CONDITIONS
WARRANTY WARRANTY CONDITIONS
WARRANTY TERMS
1. The warranty covers any manufacturing defect of the product or any components used which are acknowledged to be defective by Linergy. During the warranty period the products can be replaced or repaired according to the unquestionable judgment of Linergy. Labour and materials are completely free of charge. The guarantee becomes null and void if the material has been tampered with or repaired by personnel not authorized by Linergy
FIXED LUMINAIRES â&#x20AC;&#x201C; EMERGENCY KIT 1. The products are guaranteed for 2 years from the purchase date of the ceiling light.
2. The warranty does not apply in case of damage caused: By failure to respect the assembly, maintenance and usage instructions. By atmospheric phenomenon, overvoltages or overcurrents due to causes that are external to the product. By damage occurring during the transport. Damage occurring during transport shall be acknowledged only if a written claim is made to the carrier when the material is picked-up and a copy of said claim is given to Linergy. Damage caused by use that contradicts the technical and/or safety measures required in the country in which the products are utilized. 3. Any complaints regarding faults and/or functioning defects must be made within thirty days of their discovery or the warranty will become null and void. In the event of disputes relating to the quality and condition of the product, article 1513 of the Italian Civil Code shall apply.
2. The light sources and leds are guaranteed for 2 years. 3. The fluorescent tubes are guaranteed for 6 months. 4. The storage batteries already installed onto the luminaires are guaranteed for 4 years from the manufacturing date of the ceiling light. The storage batteries that are purchased as spare parts are guaranteed for 2 years from the manufacturing date on the condition that, what is provided for by European regulations, is applied. 5. The manufacturing date is reported on each individual luminaire via an identification code of the production batch. SPY SYSTEM and SPY CENTER 1. The guarantee on this equipment is for 2 years from the start-up date, proven by a document which Linergy must receive in writing. ACCESSORIES 1. All the fixed-luminaire accessories are guaranteed for 2 years. 2. All the accessories of the Spy System and Spy Center control units are guaranteed for 2 years from the startup date. 5 YEAR WARRANTY 1. The 5-year warranty applies only to products that have the relative logo shown on the catalogue pages. 2. The extension of the warranty to 5 years only concerns products not subjected to negligence, improper use, tampering, and/or repairs by third parties, as well as accidental damage such as lightening and/or overvoltage. 3. The electronic components, subject to normal wear over time, are excluded from the warranty.
157
CERTIFIED COMPANY UNI EN ISO 9001