NOTES - HOUSE ORIENTED SO THAT THE LIVING AREAS FACE NORTH - GARAGE HAS BEEN DETACHED AND RE-POSITIONED TO THE NORTH-WEST S
W
SW
G
- DECIDUOUS TREES EXIST IN FRONT OF LIVING AREAS
S
W
SW
G
S
W
SW
G
S
S
GP
EM
S
W
SW
G
CALLERY CRESCENT
W
G
SW
WM
S
W
SW
G
GM
E
E
E
E
CONCRETE FOOTPATH E G G
G
G
G
G
G
SW
SW
SW
SW
SW
SW
W
W
W
W
W
W
E
E G
SW SW BLUESTONE KERB AND CHANNEL W W
E
E
E
E
G
G
G
SW
SW
SW
W
W
W
W
S
S
S
S
S
E
W
E
S
S
S
S
S
S
S
S
S
SITE PLAN 1 : 200
LEGEND E G SW W S
ELECTRICITY (UNDERGROUND) GAS (UNDERGROUND) STORMWATER (UNDERGROUND) WATER (UNDERGROUND) SEWAGE (UNDERGROUND) FENCE
GP
CONCRETE BOUNDARY PROPERTY LINE WALL OUTLINE OVERHEAD POWER TELSTRA PIT GRATED DRAINAGE PIT
S WM GM EM
S
SEWAGE MANHOLE WATER METER GAS METER ELECTRICITY METER STREET LIGHT CAR GATE
EBS - ABPL 20036
SITE PLAN Name: Luke Madden
A101
Student number: 359911
Assignment 1
NORTH
ABSA House Date: 20/8/12
Scale
1 : 200
22/08/2012 12:01:55 AM
1
S
S
BENJAMIN STREET
NOTES
A
B
C
3590
5235
3680
5000
D
E
1200
10140
1200 1200
1800
380820380
4200
1520
2500
2400
220
100
2400
600
5460
2500
380
2120
- INTERNAL WALLS ARE TIMBERSTUD FRAMES WITH PLASTERBOARD AND A SINGLE LAYER OF BRADFORD GOLD R2.7 WALL BATTS.
380
- DOUBLE-GLAZED LOW EMMISIVITY GLASS USED IN ALL WINDOWS EXCEPT BATHROOM, WHICH USES TEXTURE GLASS.
90
a
2497
10520 1580
- EXTERNAL WALLS A REVERSE BRICK VENEER WITH A 180mm CAVITY TO ALLOW FOR 2 SHEETS OF BRADFORD GOLD R2.7 WALL BATTS. THIS ALSO ALLOWS THE MASS COMPONENT OF THE WALL TO BE ON THE INSIDE OF THE HOUSE AND ASSIST IN HEAT RETENTION.
F
3950 6000
GARAGE
621
3500
90
2438
5000 5621
BEDROOM 2
BEDROOM 3
9820
2100 1310
- KITCHEN/FAMILY AND BATHROOM/LAUNDRY FLOOR CONSISTS OF CERAMIC TILES ON A SUSPENDED SLAB WITH CERAMIC TILES.
1460
- REMAINING INTERNAL ROOMS FLOOR CONSISTS OF CARPET ON A SUSPENDED SLAB. - OUTDOOR LIVING AREA IS TIMBER DECKING WITH A BLADDER TANK ENCLOSED BENEATH.
1800
BATH/ LAUNDRY
3430
2860
BEDROOM 1
5570
OUTDOOR LIVING
HALLWAY
- GARAGE FLOOR IS POLISHED GROUND SLAB. - GARAGE WALLS ARE STANDARD BRICK CONSTRUCTION. - FURNITURE LAYOUT INCLUDES ONLY BASIC ITEMS.
5980 90
FAMILY
820
4720 1001000100 280
KITCHEN /MEALS
- KITCHEN/FAMILY AREA COMBINED TO ALLOW BETTER AIR CIRCULATION AND CROSS VENTILATION, BUT INTERNAL PARTIONS ARE USED IN OTHER AREAS TO ONCREASE THERMAL MASS.
1460
e
LIVING
380
4040 1460 240820 1460
4720
4340
d
1800
1800
3105
90
3300
1995
c
- BLINDS ARE USED ACCORDING TO THE CONDITIONS OF INDIVIDUAL WINDOWS.
1690
380
6180
4095
- TIMBER FRAMES USED IN WINDOWS TO MINIMISE HEAT LEAKAGE.
b
380
3600 4980
720 100
3260
2900
100
3900
1200
1950
1800
820
3440 100
2760
380
4290
14220
HOUSE PLAN 1 : 100
LEGEND CARPETED FLOOR OUTDOOR TILES KITCHEN TILES TIMBER DECKING LAUNDRY TILES POLISHED CONCRTE
STRUCTURAL WALL GARAGE DOOR INTERNAL PARTITION HOLLAND BLINDS VERTICAL BLINDS HEAVY DRAPES
EBS - ABPL 20036
HOUSE PLAN Name: Luke Madden
A102
Student number: 359911
Assignment 1
NORTH
ABSA House Date: 20/8/12
Scale
1 : 100
22/08/2012 12:01:57 AM
2
- LARGER WINDOWS ARE ORIENTED NORTH TO ALLOW MAXIMUM SUNLIGHT.
NOTES - ALL LIGHT SOURCES ARE VARIED TYPES OF LED LIGHTS. - DE LONGHI 600 x 400 TYPE 10 VERTIAL RADIATOR (HYDRONIC HEATING PANELS) USED IN BEDROOMS AND LIVING ROOOM. - CEILING FANS USED IN BEDROOMS AND LIVING ROOMS AS CONVENTIONAL COOLING IS NOT REQUIRED DUE TO HIGH THERMAL MASS EXTERIOR WALLS AND HIGHLY INSULATED GLASS. - PHONE LINES IN BEDROOMS AND LIVING ROOM TO COVER IMPORTANT AREAS IN ADDITION TO ALLOWING COMMUNICATION IN ALL ROOM WHERE IT MAY BE NECESSARY IN THE PRESENT AND FUTURE. - INTERNET CONNECTION EQUIPMENT LOCATED IN LIVING AREA TO PROVIDE SIMPLE ACCESS.
UP
- SOLAR WHIZ SW300 (PHOTOVOLTAIC EXHAUST FAN) MOUNTED ON ROOF. - 20 x SILEX SLX190 SOLAR PANELS MOUNTED ON ROOF TO PRODUCED 3.8kW PHOTOVOLTAIC SYSTEM USED ON ROOF TO COVER HOUSEHOLD ENERGY NEEDS IN ADDITION TO POTENTIALLY GENERATING EXCESS POWER.
EM
LEGEND OUTDOOR LIGHT INDOOR LIGHT SINGLE POWER POINT DOUBLE POWER POINT SINGLE POWER SWITCH DOUBLE POWER SWITCH
WIRED POWER POINT OUTDOOR POWER POINT PHONE LINE CONNECTION HYDRONIC HEATING PANEL INTERNAL SWITCHBOARD PCD
TELSTRA PIT SOLAR PANEL POWER CABLE PHONE LINE PHONE CONNECTION SMOKE DETECTOR
EM
ELECTRICITY METER CEILING FAN PSU, NTD AND FWO COMBO PANEL ROOF BOUNDARIES EXHAUST FAN
EBS - ABPL 20036
ELEC./LIGHTING/COMM. Name: Luke Madden
A103
Student number: 359911
Assignment 1
NORTH
ABSA House Date: 20/8/12
Scale
1 : 100
22/08/2012 12:01:57 AM
ELEC./LIGHTING/COMM. 3 PLAN 1 : 100
NOTES - RINNAI PRESTIME SYSTEM M SOLAR HOT WATER SYSTEM MOUNTED ON NORTH FACE OF ROOF. - HOT WATER SYSTEM SUPPORTED BY RINNAI S26 BOOSTER OUNTED ON NORTH FACE OF EXTERNAL WALL. - WATER STOP VALVE PLACED INTERMITTENTLY THROUGHOUT PROPERTY TO ALLOW EASY ACCESS.
WM
UP
GM
1 : 100
LEGEND
WM GM
HOT WATER LINE COLD WATER LINE PANEL RETURN PIPE GAS LINE WATER METER GAS METER
SOLAR HOT WATER BOOSTER HYDRONIC HEATING PANEL WATER STOP VALVE SOLAR HOT WATER PANEL ROOF BOUNDARIES
EBS - ABPL 20036
GAS/WATER Name: Luke Madden
A104
Student number: 359911
Assignment 1
NORTH
ABSA House Date: 20/8/12
Scale
1 : 100
22/08/2012 12:01:58 AM
4
GAS/WATER PLAN
NOTES - RAINWATER COLLECTED AND SENT TO RAINWATER TANK VIA DOWNPIPES AND BELOW GROUND PIPES. - 5350L WATERPLEX ECOSAC BLADDER TANK STORED BENEATH OUTDOOR LIVING AREA DECK (2100 X 5000 X 6000).
UP
- RAINWATER USED IN PREFERENCE TO TO WATER FROM WATER MAIN WHERE POSSIBLE. - RAINWATER TANK CONNECTED TO STORMWATER SYSTEM IN ORDER TO ALLOW FOR POTENTIAL OVERFLOW. - SEWAGE AND STORMWATER PIPES ANGLED TO ALLOW GRAVITY TO FACILITATE FLOW WITHIN PIPES
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW
S
S
S
S
S
S
S
S
S
S
S
S
LEGEND S SW
SEWER MAIN STORMWATER MAIN RAINWATER COLLECTION PIPE RAINWATER DISTRIBUTION PIPE SEWAGE PIPE STORMWATER PIPE
SOLAR HOT WATER BOOSTER DOWNPIPE ROOF BOUNDARIES PROPERTY BOUNDARIES
EBS - ABPL 20036
SEWER/STORMWATER Name: Luke Madden
A105
Student number: 359911
Assignment 1
NORTH
ABSA House Date: 20/8/12
Scale
1 : 100
22/08/2012 12:02:03 AM
SEWER/STORMWATER 5 PLAN 1 : 100
NOTES
NOTES
- CONVENTIONAL FURNITURE LAYOUT INCLUDES ENTERTAINMENT AREA AS WELL AS STORAGE SPACE AND OPEN SPACE TO FACILITATE ALL ACTIVITIES.
- PARTY LAYOUT FEATURES FURNITURE SET AGAINST WALLS AND A SINGLE TABLE IN THE MIDDLEOF THE ROOM IN ORDER TO ALLOW OPEN SPACE AND FREE CIRCULATION WHILE ALSO PROVIDING A SURFACE TO PLACE FOOD AND BEVERAGES ON.
- FAN LOCATED CLOSE TO THE TV IN ORDER TO RECIRCULATE THE AIR HEATED UP BY AV EQUIPMENT.
- AREA NEXT TO TV UTILISED FOR EXTRA AV EQUIPMENT SUCH AS SPEAKERS IN ORDER TO AVOID RUNNING CABLES ALONG THE GROUND AS WELL AS MAINTAINING OPEN SPACE AND FREE CIRCULATION.
- POWERPOINTS AND PHONE LINES LOCATED BEHIND TV TO AVOID RUNNING CABLES ALONG THE GROUND. - TV LOCATED ADJACENT TO WINDOW TO AVOID SUNLIGHT GLARE.
- TV REMAINS LOCATED IN THE CORNER IN ORDER TO PROVIDE AND EASILY VISIBLE LOCATION WHILE STILL AVOIDING ISSUES SUCH AS GLARE.
- LIGHTS FITTED IN TWO AREAS IN ORDER TO PROVIDE EVEN LIGHTING AND AVOID CASTING SHADOWS F OBJECTS IN THE CENTRE OF THE ROOM.
- LIGHTING ARRANGEMENT STILL REMAINS SUITABLE AS IT ALLOWS USERS SOME DEGREE OF CONTROL OVER LIGHTING IN THE ROOM.
- HYDRONIC HEATING PANEL LOCATED AWAY FROM OBSTRUCTIONSBUT STILL IN A CENTRAL LOCATION IN ORDER TO PROViDE EVEN HEAT TO THE ENTIRE ROOM.
- HYDRONIC HEATING PANEL REMAINS UNOBSTRUCTED.
LEGEND INDOOR LIGHT DOUBLE POWER POINT SINGLE POWER SWITCH DOUBLE POWER SWITCH PHONE LINE CONNECTION HYDRONIC HEATING PANEL
CEILING FAN HEAVY DRAPES
1 : 50
7
LOUNGE ROOM - PARTY 1 : 50
EBS - ABPL 20036
LOUNGE ROOM Name: Luke Madden
A106
Student number: 359911
Assignment 1
NORTH
ABSA House Date: 20/8/12
Scale
As indicated
22/08/2012 12:02:05 AM
6
LOUNGE ROOM - NORMAL