S NGLE STOREY PROJECT
QUEEN ST
,--,
PROJECT CONTENTS
,os
I 00
A01 SITE PLAN - 1:100 A02
...
FLOOR PLAN - 1:50 A03 SECTION A-A - 1:30 A04 NORTH ELEVATION & EAST ELEVATION - 1:50 AOS SOUTH ELEVATION & WEST ELEVATION - 1:50 A06 CONSTRUCTION DETAILS - 1:10
DENG LUOLIN
\
\
.,
THESE DRAWING SHALL BE READ IN CONSTRUCTION WITH ALL RELEVANT ARCHITECTURAL AND OTHER CONSULTANTS
ALL MATERIALS AND WORK PRACTICES SHALL COMPLY WITH, BUT NOT LIMITED TO THE BUILDING REGULATIONS 2018, THE
DRAWING AND SPECIFICATION AND ANY OTHER WRITTEN INSTRUCTIONS ISSUE DURING THE COURSE OF THE CONTRACT
BUILDING CODE OF AUSTRALIA 2016 & ALL RELEVANT CURRENT AUSTRALIAN STANDARDS (AS AMENDED) REFERRED TO THEREIN
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS
AS 1288 - 2006 GLASS IN BUILDING - SELECTION AND INSTALLATION AS 1562 - 1992 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDING
ALL WORKS TO BE COMPLETED BY LICENSED PRACTITIONERS
AS 1684 - 2010 NATIONAL TIMBER FRAMING CODE AS 3740 - 2004 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGS
ALL BOUNDARY CLEARANCES MUST BE VERIFIED ON SITE BY REGISTERED SURVEYOR
AS 3786 - 2006 SMOKE ALARMS AS 4100 - 1998 STEEL STRUCTURES
NO PART OF THE BUILDING SHALL PROJECT BEYOND THE BOUNDARY LINE
AS 1668.2 - 2012 THE USE OF VENTILATION AND AIR - CONDITIONING IN BUILDINGS, MECHANICAL VENTILATION IN BUILDINGS AS 1684 - ALL FRAMING
THE PREMISES SHALL BE TREATED FOR TERMITE PROTECTION USING A CHEMICAL BARRIER IN ACCORDANCE WITH AS3660
DESIGN AND CONSTRUCTION OF DRAINAGE TO BE IN ACCORDANCE AS/NZS 3500.3 OR SECTION 5 OF AS/NZS 3500.5 TO SATISFY OPENABLE WINDOWS WITHIN 1 METER OF THE FINISHED FLOOR LEVEL SHALL BE RESTRICTED SO THE OPENINGS DO NOT
PERFORMANCE REQURIEMENT STATED IN NCC PART 3.1.2
EXCEED 125MM
EXHAUST FANS: BATHROOMS SHALL BE PROVIDED WITH MECHANICAL VENTILATION
ON PLAN DENOTES LOCATION OF SEALED/SELF CLOSING TYPE EXHAUST FANS. DUCTED TO OUTSIDE AIR.
PROTECTION OF EXISTING TREES & GREENS
SMOKE ALARMS: 4. INSTALL SMOKE DETECTORS IN ACCORDANCE WITH AS3786 DIRECT WIRED TO ELECTRIC MAINS WITH STANDBY POWER.
TO ENSURE MINIMUM INTERFERENCE WITH STREETS, WALK WAYS & OTHER ADJACENT OCCUPIED OR USED FACILITIES
MARKED THUS ON PLANS. 5. SMOKE DETECTORS ARE TO BE CONNECTED TO THE CONSUMER POWER MAINS IN ACCORDANCE WITH AS3786.
WINDOW SIZES NOMINATED ARE NOMINAL ONLY. ACTUAL SIZE MAY VARY ACCORDING TO MANUFACTURER. WINDOWS TO BE FLASHED & SEALED ALL AROUND
SEWERAGE NOTE: CONNECT ALL WASTE OUTLETS TO SEWERAGE SYSTEM TO SATISFACTION OF LOCATION AUTHORITIES.
WHERE THE BUILDING (EXCLUDES CLASS 10: GARAGE) IS LOCATED IN A TERMITE PRONE AREA THE AREA TO UNDERSIDE OF
INSULATION OF ALL SERVICES SHALL COMPLY WITH THE RESPECTIVE SUPPLY AUTHORITY REQUIREMENTS. THE BUILDER AND SUBCONTRACTOR SHALL ENSURE THAT ALL DOWN PIPE AND THE LIKE ARE LOCATED AT A SUFFICIENT DISTANCE FROM ANY BUILDINGS FOOTING AND/OR SLAB EDGE BEAMS SO AS TO PREVENT GENERAL MOISTURE PENETRATION, DAMPNESS, WEAKENING & UNDERMINING OF ANY BUILDING & ITS FOOTING SYSTEM. BUILDING CONTRACTOR TO NOTIFY ARCHITECT/SUPER INTENDANT OF ANY DISCREPANCY IN DOCUMENTATION & WAIT FOR INSTRUCTION PRIOR TO CONTINUING WITH THE WORK. BUILDER TO ENSURE PROTECTING TO ALL ADJACENT PROPERTIES PRIOR TO BEGINNING WORK
FOUNDATION: IF SOIL CONDITIONS VARY TO THAT INDICATED IN THE SOIL REPORT, THE GEOTECHNICAL ENGINEER IS TO BE CONTACTED IMMEDIATELY. CLASS M SOIL TYPE FOR ARTICULATED MASONRY STEEL WORK: REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR STEELWORK DETAILS. NB: ALL EXPOSITED STEELWORK MUST BE HOT-DIPPED GALVANIZED. SITE PREPARATION: THE SITE SHALL BE PREPARED IN ACCORDANCE WITH SECTION 6 OF AS2870, PARTICULAR ATTENTION SHOULD BE GIVEN TO THE STRIPPING OF ALL VEGETATION AND TOPSOIL MATERIAL.. THE SITE SHALL BE ADEQUATELY FENCED OFF DURING CONSTRUCTION TO PREVENT PUBLIC ACCESS. ENSURE THE SITE IS SAFE AND SECURE FROM ALL ACCESS DURING NON-CONSTRUCTION PERIODS IN COMPLIANCE WITH AS1926
ALL STORMWATER TO BE TAKEN TO THE LEGAL POINT OF DISCHARGE TO THE RELEVANT AUTHORITIES APPROVAL. ALL FOUNDATION EXCAVATIONS & SITE WORKS SHOULD BE INSPECTED BY A SUITABLY QUALIFIED PERSON TO ENSURE THAT SUBSURFACE CONDITIONS & SITE PREPARATION PROCEDURES ARE IN ACCORDANCE WITH THOSE OUTLINED. IF ANY DOUBTS EXIST THEN THIS NNH ENGINEERS PTY LTD SHOULD BE CONTACTED FOR FURTHER ADVICE. ALL EXCAVATIONS TO BE CARRIED OUT IN ACCORDANCE WITH CONTROLLING AUTHORITIES REQUIREMENTS. THE BUILDER IS TO CHECK ALL LEVELS & DIMENSIONS PRIOR TO COMMENCING ANY WORKS AND ANY DISCREPANCIES ARE TO BE REPORTED TO NNH ENGINEERS PTY LTD.
RMIT - SCHOOL OF ARCHITECTURE AND DESIGN PROJECT TITLE:
CONSTRUCTION & WORKING DRAWINGS DRAWING TITLE:
CONSTRUCTION DETAILS
JOB NO:
A00
ISSUE/STAGE:
SCALE: CHECKED:
JIM KARAKIKLAS
DRAWN:
DENG LUOLIN
DATE:
A00
03/06/2019 GROUP:
D
DRAWING No
3/06/2019 9:27:39 AM, s3749594, LUOLIN_DENG
BUILDING AND PERIMETERS TO BE TREATED AGAINST TERMITE ATTACK
ADJOINING BUILDING
SHED
(NO.4)
P.O.S
HRW
P.O.S
PA
ERL 14.42
ERL 14.19
TH
32.11MT (90d23'40") HWS
DP
MB
COURTYARD
ADJOINING BUILDING
P.O.S
(NO.58)
DP
LOT 3 PROPOSED DWELLING
N
EE
9M .3 5 1
T
QU
) 0" 1 ' 44 3d 2 (3
LPOD
BRICK VENEER CONCRETE ROOF TILE (NO.2)
P.O.S
VOL: 751
FOL:372
ET
RE
ST LB
GARAGE
12.19MT (181d04'10")
HRW
NRW
DP
DP
100MM UPVC STORMWATER DRAIN FALL 1:100 MIN
ERL 14.46
ERL 14.25
22.78MT (270d0'0")
DRIVEWAY
DRIVEWAY
AREA SCHEDULE: PROPOSED BUILDING & GARAGE: 185.62m²
BL JOHN STREET
SITE AREA: 337.07m² SOIL CLASSIFICATION: H
SITE PLAN
GENERAL NOTE
LEGEND
HRW - HABITABLE ROOM WINDOW
SCALE 1:100
THE SITE SHALL BE PREPARED IN ACCORDANCE WITH SECTION 6 OF AS2870, PARTICULAR ATTENTION SHOULD BE
ERL - EXISTING REDUCED LEVEL
NHW - NON-HABITABLE ROOM WINDOW DP - DOWN PIPE
GIVEN TO THE STRIPPING OF ALL VEGETATION AND TOPSOIL MATERIAL.
- EXISTING TREES & TRUNK
HWS - HOT WATER SERVICE
LB - LETTER BOX
PROTECTION OF EXISTING TREE & GREENS.
P.O.S -PRIVATE OPEN SPACE
LPOD - LEGAL POINT OF DISCHARGE
BL - BOUNDARY LINE
DO NOT ENCROACH ON ADJACENT OCCUPIED AREAS OR AREAS NOT WITHIN THE SCOPE OF WORK. CONNECT ALL WASTE OUTLETS TO SEWERAGE SYSTEM TO SATISFACTION OF LOCAL AUTHORITIES. PLUMBER TO PROVIDE ALL NECESSARY DOWN PIPES, GUTTERS & OVERFLOW DEVICES. ALL STORMWATER TO BE TAKEN TO THE LEGAL POINT OF DISCHARGE TO THE RELEVANT AUTHORITIES APPROVAL.
NORTH POINT
MB - MATER BOX
RMIT - SCHOOL OF ARCHITECTURE AND DESIGN PROJECT TITLE:
CONSTRUCTION & WORKING DRAWINGS DRAWING TITLE:
SITE PLAN
JOB NO: SCALE:
A01 1:100
CHECKED:
JIM KARAKIKLAS
DRAWN:
DENG LUOLIN
ISSUE/STAGE:
DATE:
A01
03/06/2019 GROUP:
D
DRAWING No
3/06/2019 9:27:27 AM, s3749594, LUOLIN_DENG
% SITE AREA: 55%
ENS
GARAGE
L'DRY
OPENING
SELF SELF
ENS SKY ABOVE CB
SHR WC
PDR
BL - BOUNDARY LINE
SELF - SEALING EXHAUST FAN DR - DRYER
L'DRY - LAUNDRY
RL - REDUCED LEVEL
SA - SMOKE ALARM
SHR - SHOWER
ENS - ENSUITE
D - DOOR
REF - REFRIGERATOR
B - BASIN
PDR - POWDER ROOM
W - WINDOW
DW - DISH WASHER
W.C.- TOILET
BIR - BUILD-IN ROBE
W.M.- WASHING MACHINE
H.P - HOT PLATE
DP - DOWN PIPE
CB - CUPBOARD OVERHEAD
HWS - HOT WATER SERVICE
O.V - OVEN BELOW
M - MATER BOX
WB - WARDROBE
TR - TROUGH
P - PANTRY
PO - POST
VER - VERANDAH
S - SINK
VB - VANITY BASIN
RH - RANGE HOOD
B
SELF
CB
DP
CB
HANGING
BIR
HANGING
BIR
BEDROOM 1
FLAT ROOF OVER BOX BAY WINDOW
BEDROOM 1
L'DRY
LEGEND:
PDR
FULLY GLAZED L'DRY DOOR
DP
ENS/L'DRY
HWS
BATH
WC
MB
W.M
D
S
BL
TR
300MM BOX GUTTER OVER
VB
BL 300MM BOX GUTTER OVER
HANGING
VER
ENTRY
5400W x 2500H BI-FOLD DOOR
VER
ENTRY
RL: 9.95
RL: 10.00
ROLLER DOOR SA
SA
TIMBER DECKING
WB
REF
CB
BEDROOM 2 BEDROOM 2
TIMBER
GARAGE
LINE OF ROOF ABOVE
DW
LIVING & DINING
P
RL: 9.90
S
R.H OVER H.P
DINING
LIVING
RL: 10.00
RL: 10.00
TIMBER
O.V BELOW CB
KITCHEN RL: 9.98
900 WIDE PANTRY 900 WIDE ISLAND BENCH WALL OVEN 900 WIDE COOKTOP DOUBLE SINK
ROLLER DOOR
OPENING
OPENING
DP
DP
VER
FLOOR PLAN
BEDROOM 2
KITCHEN
ALL FRAMING MUST COMPLY WITH AS 1684
LIVING & DINING
WALLS - 240MM BRICK VENEER WALL
SCALE 1:50
ALL GLASS AND GLAZING MUST COMPLY WITH AS 1288
- 10MM PLASTER BOARD THROUGHOUT
PROVIDE SMOKE ALARM AS 3786 & BCA REQUIREMENTS
- 40MM CAVITY
GENERAL NOTE
EN SUITE & POWDER ROOM SHALL BE PROVIDED WITH MECHANICAL VENTILATION
- 90MM STUD WALL
DWELLING: FLOOR TO CEILING HEIGHT IS 2700
ALL BEAMS REFER TO ENGINEERING DRAWING FOR FURTHER DETAIL
- 110MM BRICK WALL
THE BUILDING IS ON A CONCRETE SLAB SET 150MM ABOVE GROUND LEVEL
NO PART OF THE BUILDING SHALL PROJECT BEYOND THE BOUNDARY LINE.
SOIL CLASSIFICATION: H
PROTECTION OF EXISTING TREE & GREENS.
ROOF PITCH IS 27° @ TRUSS CONSTRUCTION WITH CONCRETE ROOF TILES
REFER TO DOOR & WINDOW SCHEDULE FOR DETAILS
THE ROOF FORM IS HIP ROOF WITH GABLE OVER BEDROOM 1
INSTALLATION OF ALL SERVICES SHALL COMPLY WITH THE RESPECTIVE SUPPLY
EAVES OVERHANG IS 300MM WITH CEMENT SHEET LINING
AUTHORITY REQUIREMENTS.
NORTH POINT
FLOORING: 140 X 15 KDHW BLUEGUM FLOOR LINING BY BORAL THROUGHOUT ENTRY, BEDROOMS, DINING AND LIVING AREAS 140 X 19 F17 KDHW SPOTTED GUM DECKING FOR VERANDAH 250 X 250 PORCELAIN FLOOR TILES THROUGHOUT EN SUITE, POWDER ROOM, KITCHEN AND LAUNDRY WET AREAS TERMITE CONTROL INCLUDE TERMI-MESH AND GRANITGARD PROVIDED COMPLY WITH AS 3660.
RMIT - SCHOOL OF ARCHITECTURE AND DESIGN PROJECT TITLE:
CONSTRUCTION & WORKING DRAWINGS DRAWING TITLE:
FLOOR PLAN
JOB NO: SCALE:
A02 1:50
CHECKED:
JIM KARAKIKLAS
DRAWN:
DENG LUOLIN
ISSUE/STAGE:
DATE:
A02
03/06/2019 GROUP:
D
DRAWING No
3/06/2019 9:27:06 AM, s3749594, LUOLIN_DENG
OPENING
CONCRETE ROOF TILE BY BORAL ON 70X35 MGP10 ROOF BATTEN AT 400 CNTRS ON ROOF TRUSS AT 27° PITCH TRUSSES BY ROOF TRUSS MANUFACTURE -
PROVIDE SARKING TO MANUFACTURER'S SPECIFICATION
-
NAILING PLATE CONNECTION
RIDGE CAPPING TO MATCH THE ROOFING SPECIFIC NOTES 10MM PLASTER BOARD LINING BY BORAL ON 70X35 MGP10 CEILING BATTENS AT 400 CNTRS ON TRUSS TO MANUFACTURER'S SPECIFICATION
BL
SKY
-PROVIDE CEILING INSULATION TO ENERGY AUDIT REQUIREMENTS
A06
-90X45 DOUBLE TOP PLATE
D01
-SCOTIA PLASTER CORNICES
CL
COLORBOND 115 QUAD GUTTER ON 190X30 FASCIA PRIMED & PRINTED
10MM PLASTER BOARD LINING BY BORAL ON RH OVER
CB
300 EAVES OVERHANG
SCOTIA PLASTER CORNICES
A06
4.5MM EAVES LINING FIXED TO TRIMMER
DP BEYOND REF
D03
-PROVIDE WEATHER MOULD STEGBAR AW0626 AWNING WINDOW SECTION ON
LIVING/DINING
ARCHITRAVE PRIMED & PRINTED JOINT TO THE WALL 10° BRICK SILL 90X45 HEAD TRIMMER ON WEEP HOLE 175X45 LINTEL FACE BRICKWORK BEYOND
A06
240MM BRICK VENEER WALL
D04
KITCHEN BEYOND
NOGGING
ENTRY
RL: 10.00
DOOR BEYONG
CB BEYOND CB
STEGBAR BD2151 BI-FOLD DOOR SECTION
15MM BLUEGUM FLOOR LINING BY BORAL ON 200X16 SKIRTING PRIMED & PAINTED -PROVIDE TERMITE CONTROL INCLUDE TERMI-MESH AND GRANITGARD
-PROVIDE SISILATION TO MANUFACTURER'S SPECIFICATION INSULATION TO ENERGY AUDIT REQUIREMENT -PROVIDE SARKING TO MANUFACTURER'S SPECIFICATION
FACE BRICKWORK BEYOND FLAT BRICK SILL WITH TREAD PAVER
FL GL
WEEP HOLE BELOW PROPRIETARY STAINLESS STEEL WALL TIES 100MM UPVC STORMWATER DRAIN
150X150 REBATE
DOORS AND WINDOWS HEIGHT
-PROVIDE SARKING AND FLASHING TO MANUFACTURER'S SPECIFICATION
FALL 1:100 MIN EDGE BEAM
INTERNAL BEAM
50MM THICK SAND BED
FINISH GROUND LINE
- 10MM PLASTER BOARD THROUGHOUT
A06
- 40MM CAVITY
D02
- 90MM STUD WALL - 110MM BRICK WALL
SECTIOIN A-A
500D X 300W EDGE BEAM -PROVIDE REINFORCEMENT - TM 3-11 BELOW 150MM THICK SLAB -PROVIDE SLAB FABRIC TO MANUFACTURER'S SPECIFICATION 25MM FROM TOP
SCALE 1:30 General Notes CLASS H SOIL TYPE FOR ARTICULATED MASONRY ALL FRAMING MUST COMPLY WITH AS 1684 ALL GLAZING SHALL BE IN ACCORDANCE WITH AS 1288 WINDOW SIZE NOMINATED ARE NOMINAL ONLY ACTUAL SIZE MAY VARY ACCORDING TO MANUFACTURER. INSTALLATION OF ALL SERVICES SHALL COMPLY WITH THE RESPECTIVE SUPPLY AUTHORITY REQUIREMENTS.
LEGEND:
SKY - SKYLIGHT BEYOND
CL - CEILING LEVEL
D - DOOR
FL - FLOOR LEVEL
W - WINDOW
GL - GROUND LEVEL
CB - CUPBOARD
DP - DOWNPIPE
RH - RANGE HOOD
BL - BOUNDARY LINE
REF - REFRIGERATOR
ALL BEAMS REFER TO ENGINEERING DRASING FOR FURTHER DETAIL. REFER TO STRUCTURAL ENGINEERS DRAWING FOR STEELWORK DETAILS NB:
ALL EXPOSITED STEELWORK MUST BE HOT-DIPPED GALVANIZED
SERVICE PROFILE FIXED TO ALL WINDOWS AND DOORS THROUGH BUILDING WINDOWS TO BE FLASHED & SEALED ALL AROUND. MORE DETAIL REFER TO DETAIL DRAWING ON A06 TERMITE CONTROL INCLUDE TERMI-MESH AND GRANITGARD PROVIDED COMPLY WITH AS 3660.
RMIT - SCHOOL OF ARCHITECTURE AND DESIGN PROJECT TITLE:
CONSTRUCTION & WORKING DRAWINGS DRAWING TITLE:
SECTION A-A
JOB NO: SCALE:
A03 1:30
CHECKED:
JIM KARAKIKLAS
DRAWN:
DENG LUOLIN
ISSUE/STAGE:
DATE:
A03
03/06/2019 GROUP:
D
DRAWING No
3/06/2019 9:26:49 AM, s3749594, LUOLIN_DENG
WALLS - 240MM BRICK VENEER WALL
EAST ELEVATION
NORTH ELEVATION SCALE 1:50 General Notes
SPECIFIC NOTES
MATERNALS AND WORKNABSHIP ARE TO BE IN ACCORDANCE WITH THE RELEVANT S.A.A CODE AND THE VICTORIAN BUILDING REGULATIONS.
PROVIDE WEEP HOLE FOR BRICK WALL AT 1200 CTRS
90MM DOWN PIPE PROVIDED ON
EAVES OVERHANG IS 300MM WITH CEMENT SHEET LINING
COLORBOND 115 QUAD GUTTER ON
ALL FRAMING MUST COMPLY WITH AS1684
TIMBER WINDOWS AND DOORS REFER TO
190 X 30 FASCIA PRIMED & PAINTED
WINDOW & DOOR SCHEDULE FOR DETAIL
THE ROOF FORM IS HIP ROOF WITH GABLE
ALL GLAZING SHALL BE IN ACCORDANCE WITH AS1288 WINDOW SIZES NOMINATED ARE NOMINAL ONLY, ACTUAL SIZE MAY VERY ACCOURDING TO MANUFACTURER. WINDOW TO BE FLASHED & SEALED ALL AROUND. INSTALLATION OF ALL SERVICES SHALL COMPLY WITH THE RESPECTIVE SUPPLY AUTHORITY REQUIREMENTS. MAKE GOOD PROTECTION TO EXISTING TREE ALL BEAMS REFER TO ENGINEERING DRAWING FOR FURTHER DETAIL
LEGEND:
SKY - SKYLIGHT
CL - CEILING LEVEL
HWS - HOT WATER SERVICCE
FL - FLOOR LEVEL
MB - METER BOX
GL - GROUND LEVEL
AJ - ARTICULATION JOINTS
DP - DOWNPIPE
O - OPENABLE
BL - BOUNDARY LINE
F - FIXED
RMIT - SCHOOL OF ARCHITECTURE AND DESIGN PROJECT TITLE:
CONSTRUCTION & WORKING DRAWINGS DRAWING TITLE:
NORTH & EAST ELEVATIONS
JOB NO: SCALE:
A04 1:50
CHECKED:
JIM KARAKIKLAS
DRAWN:
DENG LUOLIN
ISSUE/STAGE:
DATE:
A04
03/06/2019 GROUP:
D
DRAWING No
3/06/2019 9:26:22 AM, s3749594, LUOLIN_DENG
SCALE 1:50
RL: 10.00 RL: 9.95
WEST ELEVATION SCALE 1:50
RL: 9.95
SOUTH ELEVATION SCALE 1:50
General Notes
SPECIFIC NOTES
MATERNALS AND WORKNABSHIP ARE TO BE IN ACCORDANCE WITH THE RELEVANT S.A.A CODE AND THE VICTORIAN BUILDING REGULATIONS.
PROVIDE WEEP HOLE FOR BRICK WALL AT 1200 CTRS
90MM DOWN PIPE PROVIDED ON
EAVES OVERHANG IS 300MM WITH CEMENT SHEET LINING
COLORBOND 115 QUAD GUTTER ON
ALL FRAMING MUST COMPLY WITH AS1684
TIMBER WINDOWS AND DOORS REFER TO
190 X 30 FASCIA PRIMED & PAINTED
WINDOW & DOOR SCHEDULE FOR DETAIL
THE ROOF FORM IS HIP ROOF WITH GABLE
WINDOW SIZES NOMINATED ARE NOMINAL ONLY, ACTUAL SIZE MAY VERY ACCOURDING TO MANUFACTURER. WINDOW TO BE FLASHED & SEALED ALL AROUND.
LEGEND:
BL - BOUNDARY LINE
RMIT - SCHOOL OF ARCHITECTURE AND DESIGN
CL - CEILING LEVEL
MB - METER BOX
INSTALLATION OF ALL SERVICES SHALL COMPLY WITH THE RESPECTIVE SUPPLY AUTHORITY REQUIREMENTS.
FL - FLOOR LEVEL
AJ - ARTICULATION JOINTS
GL - GROUND LEVEL
O - OPENABLE
DP - DOWNPIPE
F - FIXED
ALL GLAZING SHALL BE IN ACCORDANCE WITH AS1288
MAKE GOOD PROTECTION TO EXISTING TREE ALL BEAMS REFER TO ENGINEERING DRAWING FOR FURTHER DETAIL
PROJECT TITLE:
CONSTRUCTION & WORKING DRAWINGS DRAWING TITLE:
SOUTH & WEST ELEVATIONS
JOB NO: SCALE:
A05 1:50
CHECKED:
JIM KARAKIKLAS
DRAWN:
DENG LUOLIN
ISSUE/STAGE:
DATE:
A05
03/06/2019 GROUP:
D
DRAWING No
3/06/2019 9:26:01 AM, s3749594, LUOLIN_DENG
RL: 10.00
ALL FRAMING MUST COMPLY WITH AS 1684 ALL GLAZING SHALL BE IN ACCORDANCE WITH AS 1288 WINDOW SIZE NOMINATED ARE NOMINAL ONLY ACTUAL SIZE MAY VARY ACCORDING TO MANUFACTURER. WINDOWS TO BE FLASHED & SEALED ALL AROUND.
LEGEND:
INSTALLATION OF ALL SERVICES SHALL COMPLY WITH THE RESPECTIVE SUPPLY AUTHORITY REQUIREMENTS.
CL - CEILING LEVEL
PROTECTION OF EXISTING TREE
FL - FLOOR LEVEL
ALL BEAMS REFER TO ENGINEERING DRAWING FOR FURTHER DETAIL
GL - GROUND LEVEL
TERMITE CONTROL INCLUDE TERMI-MESH AND GRANITGARD PROVIDED COMPLY WITH AS 3660.
BL - BOUNDARY LINE
RMIT - SCHOOL OF ARCHITECTURE AND DESIGN PROJECT TITLE:
CONSTRUCTION & WORKING DRAWINGS DRAWING TITLE:
CONSTRUCTION DETAILS
JOB NO: SCALE:
A06 1:10
CHECKED:
JIM KARAKIKLAS
DRAWN:
DENG LUOLIN
ISSUE/STAGE:
DATE:
A06
03/06/2019 GROUP:
D
DRAWING No
3/06/2019 9:34:36 AM, s3749594, LUOLIN_DENG
General Notes