Load
Traction Power Supply System • 66 kV System • Receiving Substations 66/33kV to 11kV • 33 kV Cable Distribution System • Auxiliary Substations - 33kV / 415V • Traction Substations – 33kV / 750 V dc • 750 V DC Third Rail System • Earthing, Bonding and Stray Current Mitigation & Monitoring
System • SCADA and ETS system
4
Earthing Design and Require Result • For substation Large Power below 1.00Ohm • For substation Small Power below 2.00Ohm • SCADA/TELECOM and AutomationFor substation Large Power below 0.50Ohm • Tower and Other Structure between 8-15Ohm • Lightning Surge Protection 50KA below 5Ohm or 100KA between 8-15Ohm • Follow Standard IEC /IEEE • Recommended use of Hybrid Metal to Protect from Theft Copper Clad Steel/Alumineum Clad Copper • Exothermeic weld IEEE 837
Global Rolling Stock and Green Power
Importance of Public Time & Money
Power System for Rolling Stock and Others
Power Systems
Indian Train Movement Watch Direction and Controls Systems
Infotainment &Telecom Equipments
My Gudget My Confidence My Safety
Smart Buildings is not enough We require Protection from Fire and Safety
External/Internal Surge Source
Follow Safety in Electrical Instalation Shocks
Surge in Systems and Result
Surge in DC Application
An Arcing Fault is the flow of current through the air between phase conductors or phase conductors and neutral or ground. Concentrated radiant energy is released at the point of arcing an a small amount of time resulting in Extremely High Temperature.
Fire Accident Reason Lose Contact Earthing Disorder and Lightning
Sikhana to Padega Hi Follow NBC2016
Railway Signal & Telecom Instalation Advisory
Grid/Earth Mat Design as per IEEE80
RDSO S&T Spec forEarthing Design and Solution
Earthing Design and Solution
Copper Clad Steel Advantages as Per IEEE80
Most Efficient Joint Process/Fail Proof as per IEEE 837
It is efficient and superior to all existing surface –to-surface mechanical retention connectors.
ESE Installation Guidence
ESE AT with radius protection form 32 mtr to 107 mtr. DMC Insulator .
GI/FRP Mast .
Down Conductor Copper / Copper Cadmium Cable 70 sq. mm Copper Bonded Ground Earthing
Lightning Strikes Lost of Lives and Assests
A strike can average 100 million volts of electricity Current of up to 100,000 amperes Can generate 54,000 oF Lightning strikes somewhere on the Earth every second Kills Many Live
Facts about Lightning • A strike can average 100 million volts of electricity • Current of up to 200,000 amperes • Can generate 54,000 oF • 10/350MicroSec/50KA Fault Current/Discharge in Nano Sec Protection Earthing Design100KA Fault Current/Joints Exothermic /Flexible Down Conductor with Shortest Route & Less Corner
PASSIVE PROTECTION SYSTEM
The ESE air terminal is a terminal which enables to generate artificially an upward leader earlier than a simple rod, with an ionization system, in order to establish a special impact on its point. The capture of the lightning strike being faster than a simple rod, this technology enables to benefit from larger protection areas, ensuring protection for large dimensions structures. The ge erated protectio radius depe ds o the early strea er e issio value of the air ter i al Δt i ¾s , its height, and the efficiency of the protection. The protection radius ensured by this type of air terminal is 120 m (Protection level IV, height = 60 m , early streamer emission time 60¾s) The NFC 17-102 standard describes the installation procedure for this type of air terminal. The installation of this type of air terminal is easy and cheaper than other technologies. It can protect whole buildings with one E.S.E. air terminal. It enables the protection of a structure and its environment, the protection of opened areas and well integrate in the architecture of a structure without aesthetic alteration.
1 ESE, 2 down conductors and 2 earthing systems are necessary to ensure the protection below :