Presentation Merging with Technologies
July 2017
INDIA Water and Environment VISION/SMART VISION INDIA Drinking Water & Treatment Project AMRUT Govt of India
Jawaharlal Nehru National Urban Renewal Mission (JNNURM), Smart Cities Mission (SCM) and Swachh Bharat Mission (SBM) Now Known as Atal Mission Rejuvenation & Urban Transformation (AMRUT) Rs.50,000.00 Crores JNNURM. These schemes are (1) the Atal Mission for Rejuvenation and Urban Transformation (AMRUT), focussing on water supply and sewerage improvement; (2) Smart Cities Mission (SCM), aimed at developing smart solutions for selected urban areas; (3) Swachh Bharat Mission (SBM), focussed on waste management and sanitation; and (4) Heritage City Development and Augmentation Yojana (HRIDAY), for addressing the development of heritage cities
India Govt Commitments to Citizen
Sikhana to Padega Hi Follow NBC2016
SCOPE in Project • Design, Engineering, Procurement, Supply and installation of all instruments, PLC and • SCADA based control systems for operation, control and monitoring of Water Treatment • Plant, intake and the downstream clear water reservoirs such as MBR(Master Balance Reservior Design, Engineering, Procurement, fabrication, • Supply anderection/installation/construction of Poly Aluminium chloride (PAC) storage tank, pumps • including all Civil, Structural, Mechanical, Electrical, Instrumentation and Piping works, • Acid / Alkali proofing / lining / tiling, Inspection works, Painting works, Storage at site, • Testing, tie up with existing system & commissioning including spares up tocommissioning and all other works
Process Information • • • • • • •
The treatment process involves, Intake well and pumping Aeration Coagulation with addition of chemicals Flocculation and clarification Filtration Chlorination
Process Informarion
AMRUT Programme
Electrical and Control Automation
Electrical and Control Automation
Follow Safety in Electrical Instalation Shocks
Earthing Design and Require Result • For substation Large Power below 1.00Ohm • For substation Small Power below 2.00Ohm • SCADA/TELECOM and AutomationFor substation Large Power below 0.50Ohm • Tower and Other Structure between 8-15Ohm • Lightning Surge Protection 50KA below 5Ohm or 100KA between 8-15Ohm • Follow Standard IEC /IEEE • Recommended use of Hybrid Metal to Protect from Theft Copper Clad Steel/Alumineum Clad Copper • Exothermeic weld IEEE 837
Protection from Lightning Charges
Surge in Systems and Result
Surge in DC Application
Electrical and Control Automation
Electrical and Control Automation
Surge Protection user guide
Surge Protection use Recommendation
v
External/Internal Surge Source
An Arcing Fault is the flow of current through the air between phase conductors or phase conductors and neutral or ground. Concentrated radiant energy is released at the point of arcing an a small amount of time resulting in Extremely High Temperature.
JMV LPS Products
Copper Cladded Conductor For Electrical Installation
The Copper Clad Steel Grounding Conductor is made up of steel with the coating of 99.99% pure copper. These conductors/ wires or strands are equipped with the strength of steel with the conductivity and copper with the better corrosion resistance property. The concentric copper cladding is metallurgic ally bonded to a steel core through a continuous, solid cladding process using pressure rolling for primary bonding. The copper cladding thickness remains constant surrounding steel. We use different steel grades for the steel core result in Dead Soft Annealed, High strength and Extra High Strength Characteristics. The Copper Clad Steel Wire yields a composite conductivity of 21%, 30% and 40% IACS, and available in Annealed and Hard drawn. We are delivering products with varied conductivity and tensile strength as per the customer need. Further, the wire can be processed to be silver plated or tinned copper clad steel wire.
Most Efficient JointProcess
It is efficient and superior to all existing surface –to-surface mechanical retention connectors.
What is Exothermic Welding System? Copper to Bi-Metal and Alumenium Types of Exothermic Joints:
Possible to join any bi metal except aluminum Exothermic welding is a process of making maintain free highly molecular bonding process is superior in performance connection to any known mechanical or compression-type surface-to-surface contact connector. Exothermic weld connections provide current carrying (fusing) capacity equal to that of the conductor and will not deteriorate with age. It offers Electrical connections between two or more copper to copper and copper to steel conductors. Highly portable method as it does not require any external power source or heat source, so it can be done almost anywhere. It provides strong permanent molecular bond among metallic conductors that cannot loosen and further will not deteriorate with age. Connection does not corrode with time and it offers permanent conductivity.
Copper Clad Steel Solid ROD and Conductor
LIGHTNING FORMATION
Facts about Lightning • A strike can average 100 million volts of electricity • Current of up to 200,000 amperes • Can generate 54,000 oF • 10/350MicroSec/50KA Fault Current/Discharge in Nano Sec Protection Earthing Design100KA Fault Current/Joints Exothermic /Flexible Down Conductor with Shortest Route & Less Corner
• Lightning Protection Standard use in India (IS2309 Now IEC 62305-5)NBC2016 Working Principle Angullar No Compromise with Design Max Protection 30Mtrs from One No Product warrenty from Manufacturer High Maintenance Require NFC17-102(2011) Now Europeon Standard(ESE LA) Working Principle Radius Compromise with Design Possible with Increasing Qty of ESE Max Protection 109 Mtrs Radius from One Manufacturing Warrenty and Test Certificate for Products Available Maintenance on Call Basis
PASSIVE PROTECTION SYSTEM
The Simple Rod air terminal is composed from a metallic rod with 2 to 8 m height dominating the structure to protect, and linked to 2 down conductors minimum, and 2 earthing systems. The protection radius ensured by this air terminal which is limited to 30 m more or less (Protection level IV, height = 60 m), especially dedicated to the protection of small structures or areas like to ers, hi eys, ta ks, ater to er, a te a asts‌ The EN 0 -3 standard describes the installation procedure for these air terminals. 13 Simple Rods, 13 down conductors, and 13 earthing systems are necessary to ensure the protection below :
The meshed cage protection is composed from a meshing in roof surface and in the front face around the uildi g. Surrou di g the roof surfa e, a d o high poi ts, apture poi ts are positio ed. A o du tors’ network is placed at the outer perimeter of the roof. This network is completed by transverse conductors. The size of the meshing is 5 to meters, and depends on the efficiency needed for the protection. On the front face of the building, the down conductors are linked at the top to the meshing of the roof. And, down, to specific earthing systems. The distance between two conductors is 10 to 25 meters, and depend on the efficiency needed for the protection. The EN 62305-3 describes the installation procedure for this method. Generally, this method is heavy and expensive, due to the complexity of the structures to protect. 26 capture points, 26 down conductors and a grounded loop earthing system are necessaries to ensure the protection of the structure here below :
The catenary wires protection is a method closed to the meshed cage principle, because it is constituted with meshing of the conductors far from the structure to protect, to avoid any contact with lightning current. Catenary wires are located over the structure to protect, connected to down conductors and specific earthing systems. The width of the meshing and distance between the down conductors must respect the same rules as for the meshed cage. The EN 62305-3 describes the installation procedure for this method. Generally, this method is heavy and expensive, due to the complexity of the structures to protect.
The ESE air terminal is a terminal which enables to generate artificially an upward leader earlier than a simple rod, with an ionization system, in order to establish a special impact on its point. The capture of the lightning strike being faster than a simple rod, this technology enables to benefit from larger protection areas, ensuring protection for large dimensions structures. The ge erated prote tio radius depe ds o the early strea er e issio alue of the air ter i al Δt i ¾s , its height, and the efficiency of the protection. The protection radius ensured by this type of air terminal is 120 m (Protection level IV, height = 60 m , early streamer emission time 60¾s) The NFC 17-102 standard describes the installation procedure for this type of air terminal. The installation of this type of air terminal is easy and cheaper than other technologies. It can protect whole buildings with one E.S.E. air terminal. It enables the protection of a structure and its environment, the protection of opened areas and well integrate in the architecture of a structure without aesthetic alteration. 1 ESE, 2 down conductors and 2 earthing systems are necessary to ensure the protection below :
Installation
ESE AT with radius protection form 32 mtr to 107 mtr. DMC Insulator .
GI/FRP Mast .
Down Conductor Copper / Copper Cadmium Cable 70 sq. mm Copper Bonded Ground Earthing
Thimble
Joint all phase wire/ cable with the help of crimping tools and lugs Step – 1
Separation Sheet Fixed the separation sheet between all wires/ cables
Step – 2
Gel / Silicon Close the filled Silicon enclosure from top and bottom , complete installation is done.
Step – 3
Features : Provides cable with cable connections and jointing wires in switchboard / electric boxes Being a jelly it can be easily fit into molds of any shape and size. Helps in safeguarding electrical connections and also protects electrical connection joints from catching fire, sparking and leakage current. Eradicates all the possibilities of fire, electric shocks and sparks, etc. causes due to improper electrical connection joints and safeguards structure, equipment and person. Offers safety to your electrical joints from ageing, corrosion, moisture and also observes leakage current.
Advantages : Nontoxic Insulating Highly reliable operation Maintenance Free Repairable Cost Effective High repeat value Elasticity Shape retention