GW-IMP-WEB-1 DATALOGGER PULSE COUNTER MODBUS TCP/MODBUS RTU

Page 1

MarCom

Datalogger web pulses counter Code: GW-IMP-WEB-1 Version 6 inputs with Ethernet

Datalogger web pulses counter The web datalogger pulses counter is able to count the pulses on digital inputs (2 by default expandable). Through the web interface it is possible to display count values, change the weight of the pulse and enter an offset in the event of misalignment or assembly after the installation of the counter. All data can be viewed via web interface or reachable via MODBUS TCP connection (on request also via MODBUS RTU). The datalogger as optional feature can be ordered with time triggered recording of the counters on csv files in the internal memory or in a SD card. Files can be downloaded via ftp Server functionality.

Marcom Srl, Via Mezzacampagna 52 Verona 37125

www.marcomweb.it

1-EN


MarCom

Features Connections       

1 x Serial Port RS232 for reading data from a master Modbus RTU 1 x Ethernet port for reading data from a master Modbus TCP 1 screw connector for power supply 10 30 VDC (min. 2 W) Signaling LED on the front for communication diagnostic 6 x Digital Input 4 x Digital Output 2 x Analog Input

Analog Input Connections

Serial Ports Connections

Marcom Srl, Via Mezzacampagna 52 Verona 37125

www.marcomweb.it

2-EN


MarCom

Web visualization To view the web pages containing the data it is necessary to connect the data logger to the Ethernet network through the RJ45 port. On a web browser just enter the default address: 192.168.0.122; If you do not connect, check that you have an address on the network card of the computer on the 192.168.0.X subnet. This way you get to the main screen of the data logger with the values of the counters.

From this page, through the links at the top of the page, you can access the following pages: - Setting datalogger: Page to set the pulse counter parameters, such as pulse weight and count offset. - Hardware setup: Page to modify the hardware parameters of the pulsecounter as IP address and modbus communication parameters. - Time setup: Page to change the time or activate the NTP protocol. - System: Page to log in to enable changes and to reboot the system.

Marcom Srl, Via Mezzacampagna 52 Verona 37125

www.marcomweb.it

3-EN


MarCom

Datalogger Settings

In the datalogger setting page you can reset the values of the counters, change the weight of the pulses and the offsets.

Marcom Srl, Via Mezzacampagna 52 Verona 37125

www.marcomweb.it

4-EN


MarCom

Hardware setup

After modifying and saving the parameters, the device must be restarted. This can also be done from the System page.

System

In this page you can login (Username = Admin, Password = Admin), necessary to change the 5-EN Marcom Srl, Via Mezzacampagna 52 Verona 37125

www.marcomweb.it


MarCom parameters, and force the device to restart.

Mapping of Modbus memory areas The data read by the PLC are placed in the memory area Holding Register, they occupy 2 WORD, that is 4 BYTE. Nome variabile RESET INPUT 1 INPUT 2 INPUT 3 INPUT 4 INPUT 5 INPUT 6 CONTATORE 1 CONTATORE 2 CONTATORE 3 CONTATORE 4 CONTATORE 5 CONTATORE 6 PESO_IMP_1 PESO_IMP_2 PESO_IMP_3 PESO_IMP_4 PESO_IMP_5 PESO_IMP_6 OFFSET_1 OFFSET_2 OFFSET_3 OFFSET_4 OFFSET_5 OFFSET_6

Tipo UINT UINT UINT UINT UINT UINT UINT REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL

Indirizzo MODBUS 4x40000 4x40001 4x40002 4x40003 4x40004 4x40005 4x40006 4x41024 4x41026 4x41028 4x41030 4x41032 4x41034 4x41074 4x41076 4x41078 4x41080 4x41082 4x41084 4x41124 4x41126 4x41128 4x41130 4x41132 4x41134

Note Reset dei contatori 1° ingresso digitale 2° ingresso digitale 3° ingresso digitale 4° ingresso digitale 5° ingresso digitale 6° ingresso digitale 1° contatore: riferito all’ingresso 0 2° contatore: riferito all’ingresso 1 3° contatore: riferito all’ingresso 2 4° contatore: riferito all’ingresso 3 5° contatore: riferito all’ingresso 4 6° contatore: riferito all’ingresso 5 Peso assegnato per gli impulsi sul contatore 1 Peso assegnato per gli impulsi sul contatore 2 Peso assegnato per gli impulsi sul contatore 3 Peso assegnato per gli impulsi sul contatore 4 Peso assegnato per gli impulsi sul contatore 5 Peso assegnato per gli impulsi sul contatore 6 Offset del contatore 1 Offset del contatore 2 Offset del contatore 3 Offset del contatore 4 Offset del contatore 5 Offset del contatore 6

Marcom Srl, Via Mezzacampagna 52 Verona 37125

www.marcomweb.it

6-EN


MarCom

Gateway Size The dimensions of the gateway are as follows:

Marcom Srl, Via Mezzacampagna 52 Verona 37125

www.marcomweb.it

7-EN


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.