InGateway 601 Intelligent Cellular Gateway Cellular Routing, Text Message Alarms, Remote Secure Access
InGateway 601 The InGateway 601 series, integrating 3G cellular routing, Modbus data acquisition, text message (SMS) alarmsand VPN technology into a compact industrial grade gateway, establishes a new standard inremote access.The IG601 is the total solution for any PLC or device. As a part of InHand Networks’ industrial cellular portfolio, the IG601 can ensure a reliable, secure connection to the 3G network. From the rugged design to the built in automatic recovery mechanisms, the IG601 can ensure critical applications stay connected. While providing a suite of VPN features, the IG601 guarantees data security. The IG601 is not only cellular router, but also an intelligent gateway, supporting industrial protocols like Modbus over TCP/IP, IEC101 to 104 and DC protocol. The IG601 can monitor PLCs andequipment, and cansend an alarm by text message if the user-defined conditions are triggered. It notifiesresponse personnel immediately, in the field or in the office. Working with the cloud based InHand Device Touch,the IG601 can access a PLC’s serial or Ethernet port with its native software tools, allowing techs to program remote PLCs just as if the deviceswere by their side, and the connection is secured by an automatic VPN tunnel. InGateway is the intelligent companion for your PLC or device. 1/7
Key Features
Rugged Design For Industrial Environment
EMC levels 3, exceeding industrial standards
Ethernet port : 1.5kv, Serial port: 15kv ESD protection
Wide temperature range: -20~ 70C
Wide input voltage range: 12 ~ 24VDC
IP30 metal enclosure
DIN rail or wall mounting bracket.
Cellular Routing
Supports 3G Networks: HSPA+, EV-DO
VPN: GRE, L2TP, PPTP, IPSec, OpenVPN, Certificates
Firewall: Stateless Packet Inspection, Intrusion Protection, DDoSPrevention, IP to MAC binding, DMZ, Virtual IP Mapping
VRRP: Multiple Redundant Routers
Remote Access
Supports InHand Device Touch to build secure tunnel for remote PLC and machines
Secure tunnel can be built on demand
Operator access control and traceable historical records
Bi-directionalText Message Function
SMS Inquiry and Control via Modbus overthe serial or Ethernet port
Text Message Alarm, trigged by predefined criteria
Intelligent white list function improves security
Serial Port Networking
Protocols converting between serial and Ethernet: Modbus RTU & TCP
Multiple virtual serial links
Simplify Management
Intuitive with web configuration interface
Text Message to Inquiry Status, Reboot the IG601
Support InHand Device Manager: centralized network management
IG601 can be managed easily, whether for a single installation or large scale system
2/7
Specifications IG601 Software Specifications IG601 CellularStandard Networking
Band Options Network Access IP
HSPA+/UMTS/EDGE/GPRS/GSM CDMA 1xEVDO Rev.A/1xEVDO Rel0/1xRTT UMTS/HSPA+ 850/900/1800/1900/2100MHz CDMA 800/1900MHz APN, VPDN, Access Authentication CHAP/PAP/MS-CHAP Ping, Trace, DHCP Server, DNS Relay, DDNS, Telnet SPI, DDoS protection, Stateless Packet Inspection
Networking Security
Filtering Multicast/Ping package, Access Control List (ACL) NAT, DMZ, Port mapping
Security Data Security
GRE, L2TP,PPTP, IPSec, OpenVPN, Certification
Management
HTTPS
Auto-Recovery
Hardware Watchdog
Reliability Link Status Detection Bi-directional Text Message (SMS) Functions Application Functions
Remote Maintenance
Data Acquisition Configuration
Network
SMS Inquiry and Control: with authorized cellular number, to inquire data, configure or control remote PLC/device InHand Device Touch.Remote PLCprogramming via serial/Ethernet port Acquire local data (via Modbus) and feed into monitoring center, Support InHand Device Sense for a web-based SCADA interface Configure via Serial Port, Telnet, Web Via Web interface or InHand Device Manager
Log
Local log, remote log, export log via serial port
Text Message (SMS) On-Demand Dial Up Device Manager InHand Device
(Not included)
Broadcasts a text message when an alarm criteria is trigged
Firmware Upgrade
Management
Cloud
Reconnects automatically when link failure is detected.
Device Touch Device Sense
Interactive text messaging, allowing SMS commands like ‘Reboot’ or ‘Status.’ Trigger by data on port, text message or by predefined schedule Centralized network management for thousands of devices, batch configuration, bandwidth usage, connection status and location data. Remote access PLC, virtual serial, dual VPN tunneling,OpenVPN with TLS tunneling for anonymity and security Remote monitoring, Real-time data,Simple web interface
3/7
IG601Hardware Specifications IG601 Ethernet Port
1, RJ45, 10/100 Mbps auto-sensing 3 Pole Industrial Wiring Terminal
Power Supply
Input Voltage: 12 to 24VDC Power Consumption: 200mA @ 24VDC
Interface
Serial Port SIM Holder Reset SMA connector Mounting Dimension (mm)
RS-232/485, 5-pin Industrial Terminal Block Connector 15 kV Isolated Serial Port Drawer Card Holder x1 Pinhole Reset Button One Standard SMA Connector with a Female Inner Pin DIN-Rail, or wall mounted (additional accessory shall be ordered) 80 x 45 x 90
Mechanical
Dimension (in)
Features
Weight
340g
Enclosure
Metal
IP Level
IP30
Cooling
No Fan
Humidity
5 ~ 90% relative humidity (noncondensing)
Environment Temperature
3.1 x 1.8 x 3.5
Storage Temp
-40 ~ 85C, -40 ~ 185F
Working Temp
-20 ~ 70C, -5 ~ 160F
LED Indicators
POWER, STATUS, WARN, ERROR, MODEM, SIM, Three Levels of Cellular Signal Strength EN61000-4-2,level 3 EN61000-4-3,level 3 EN61000-4-4,level 3 EN61000-4-5,level 3
EMC & Physical Specifications
EN61000-4-6,level 3 EN61000-4-12, level 3 EN61000-4-11, Voltage Dip: 70% Shock Test: IEC60068-2-27 Free Fall: IEC60068-2-32 Vibration: IEC60068-2-6
4/7
Applications
1. Secure Remote Connectivity Reliable, Secure Remote Networking Utilizing ubiquitous cellular networks, the IG601 helps you to connect your remote machines for remote monitoring, SCADA, equipment maintenance, vending operations, wind turbines, ATMs and more. The IG601 ensures your equipment stays protected and connected.
2. Easily manage your PLC by text message Text-Messaging The IG601 allows engineers to monitor their device, receive alarms, or even reboot the device via a short text message or SMS. Get notified before equipment fails. Text-messaging ensures you stay connected.
3. Remote Programming and Diagnostics
5/7
InHand Device Touch The InHand Device Touch Cloud allows technicians to remotely program, monitor and diagnose a PLC. InHand Device Touch software is a one-click solution and provides all the security of a VPN without any complex VPN configuration InHand Device Touch is a simple, secure and powerful tool for the mobile age.
Dimensions (mm)
DIN-Rail Mount
Wall Mount (Order accessory separately.)
Ordering Information Features Part Number N, W
InGateway601Part Number IG601-<NW> N = Network W=Module
Sample Accessory
P:HSPA+
V:EVDO
GPRS/CDMA
S08:Cinterion H09: Huawei
S08:Cinterion
N/A
IG601-PS08:HSPA+ with a Cinterion/Gemalto module Standard antenna included, external power supply or adapter not included * Please contact InHand Networks for more update information. 6/7
InHand Networks InHand Networks provides reliable, secured and intelligent M2M solution for electric power, industrial automation,
commercial
and
medical
devices.
Recognized by world class customers and partners, Proven by a large install base,Expanding with intensive investments in research and development andEnduring for long-term support.
InHand Networks has become leader in industrial grade network technology by providing industrial cellular routers, industrial Ethernet switches, wireless sensor network devices and cloud based M2M platforms.
Connecting devices, enabling service.
InHand Networks Headquarters West Wing, 11th Floor, Qi Ming International Mansion Wang Jing Science Park, Chao Yang District Beijing, 100102, China T:+86-10-6439-1099 F:+86-10-8417-0089 info@inhandnetworks.com
US Office 7926 Jones Branch Dr. Suite 110 McLean, Virginia22102 USA T: +1-703-348-2988 F:+1-703-348-2988 www.inhandnetworks.com
7/7