OPC Server S7.NET - Comunication with PLCs S7300 S7400 ET200 ...
1 di 4
http://www.marcomweb.it/wiki/OPC-Server-S7-NET-Comunication-wi...
OPC Server S7.NET - Comunication with PLCs S7300 S7400 ET200 S71200 S7200 Stampa (4) » OPC SERVER CBUS PER IRC MULTICONTROLLERS HONYWELL » OPC Server CBUS PER FAMIGLIA HONEYWELL 5000 » OPC Server S7.NET Comunication with PLCs S7300 S7400 ET200 S71200 S7200 OPC Server S7.NET is ideal tool for connecting field devices with S7 Ethernet interface(PLC S7 300, S7 400, ET200 PROFINET, S7 1200, S7200) with control systems, SCADA or data collecting software. The main features of OPC Server S7.NET are: Linking to multiple PLCs by Ethernet network Variables scale inside OPC Server Compatible with WIN NT 4.0, WIN 2000, WIN 2003, WIN XP e WIN VISTA, WIN 7 ( 32 and 64 bit) Smart Configurator with automatic control of syntax errors and address errors Import/Export of configurations created OPC Data Access 2.04 Support of block trasfer with settable size to optimize comunication Analyzing and recording of comunication datas on the network (performance analysis) Manage all type of data inside PLC Comunication diagnostic at OPC variable level Write function already inside OPC Serve by configuration window It can run as Windows Service, for computers without GUI. Link to product
Indice dei Contenuti [Nascondi/Mostra] Configuration Debug and starting options Variables Automatic Import from STEP 7 Projects
Configuration Project devices variables configuration is made by a simple grafich interface.
From here you can add new devices and PLC variables, as well as modify existing entities. The configuration is done via simple windows:
31/03/2012 15:06
OPC Server S7.NET - Comunication with PLCs S7300 S7400 ET200 ...
2 di 4
http://www.marcomweb.it/wiki/OPC-Server-S7-NET-Comunication-wi...
Window settings PLC
Window variable settings
Debug and starting options Follow windows show debug and start options:
31/03/2012 15:06
OPC Server S7.NET - Comunication with PLCs S7300 S7400 ET200 ...
3 di 4
http://www.marcomweb.it/wiki/OPC-Server-S7-NET-Comunication-wi...
Variables Automatic Import from STEP 7 Projects OPC Server S7.NET has an adavanced function to import variables automatically from STEP7 projects. This give selection windows which reduces a lot time for variable configuration in OPC Server S7.NET.
31/03/2012 15:06
OPC Server S7.NET - Comunication with PLCs S7300 S7400 ET200 ...
4 di 4
http://www.marcomweb.it/wiki/OPC-Server-S7-NET-Comunication-wi...
IMPORT WINODOWS FROM STEP7 PROJECTS
VARIABLES IMPORT WINDOWS FROM STEP7 PROJECT
Evaluate article contents