COTE SUPER SPREADSHEET - INTRODUCTION
Step 1: Fill out the below basic information of your project
Basic Project Information Project Name Project Address apt., suite, etc. City State Zip Code ASHRAE Climate Zone Other Climate Zone(?): Total Building Area(?) Site Area(?) Regularly occupied space(?) Avg daily occupancy(?) Peak occupancy(?) FTEs(?) Project completion year Annual days of operation(?) Avg. daily hours of operation(?) Total Construction Cost(?) FAR Cost/sf ($ sf/occupant - Avg. sf/occupant - Peak Annual hours of operation
AXIS Building 39 Quincy Ave.
Braintree MA 2184 5A (Link)
15,000 Gross sf 390,000 sf 10,000 sf 50 People 100 People 20 People 2022 365 Days 10 hours 10,000,000 USD 0.04 666.67) 300 150 3,650
Building Program
Program Breakdown(?) Building Program #1 Food - Restaurant Building Program #2 Recreation (Visitor Center) Building Program #3 Building Program #4 Building Program #5 Building Program #6 Building Program #7 Building Program #8 % of Building Area 30% 70%
Total must equal 100% 100% Program Breakdown(?) Building Program #1 Food - Restaurant Building Program #2 Recreation (Visitor Center) Building Program #3 Building Program #4 Building Program #5 Building Program #6 Building Program #7 Building Program #8
Total must equal 100% 100%
Step 2: Review your benchmarks to evaluate your projects performance.
Transportation Additional Building Information Total Annual Project Type New Construction Total Annual per OccupantSite Environment(?) Urban Previously Developed Site Yes - Brownfield WaterIs the firm an AIA 2030 Signatory No Total Annual Water UseReported in the AIA DDx No WUI - Water Use Intensity (Program-based)Third party rating system 1 WUI - Water Use Intensity (User-Defined)Third party rating system 2 Water Use per OccupantThird party rating system 3 If other, specify
Energy
Total Annual Energy Use EUI - Energy Use Intensity (Program-based) EUI - Energy Use Intensity (User-defined) Energy Use per Occupant
86,462 1,729
973,500 0.0 64.9 19,470
2,052,000 136.8 136.8 41,040
kg-CO2e / yr kg-CO2e / occupant / yr
gal / yr gal / sf / yr gal / sf / yr gal / occupant / yr
kBtu / yr kBtu / sf / yr kBtu / sf / yr kBtu / occupant / yr
Operational Carbon Emissions
Total Annual Carbon Emissions Carbon Use Intensity (Program-based) Carbon Use Intensity (User-Defined) Carbon Emissions per Occupant
183,000 12.2 12.2 3,660
kg-CO2e / yr kg-CO2e / sf / yr kg-CO2e / sf / yr kg-CO2e / occupant / yr
Electric Lighting
Lighting Power Density Lighting Power Density (User-Defined)
1.22 1.22
W / sf W / sf
This first page assigns benchmarks based on building-specific, national data for the project to be compared against.
If a user-defined benchmark is present, the national benchmarks will be overridden.
For COTE Top Ten energy reductions, the benchmark should be user-defined using Architecture 2030's Zero Tool. Optional user-defined benchmarks can be entered above as a way of tracking any specific benchmarking research that the team conducted.
COTE SUPER SPREADSHEET - INTRODUCTION
Step 2: Review your benchmarks to evaluate your projects performance. Transportation
Total Annual 86,462 kg-CO2e / yr
Total Annual per Occupant
1,729
kg-CO2e / occupant / yr
Water
Total Annual Water Use WUI - Water Use Intensity (Program-based) WUI - Water Use Intensity (User-Defined) Water Use per Occupant
973,500 0.0 64.9 19,470
gal / yr gal / sf / yr gal / sf / yr gal / occupant / yr User-Defined Benchmark Source
Energy
Total Annual Energy Use EUI - Energy Use Intensity (Program-based) EUI - Energy Use Intensity (User-defined) Energy Use per Occupant
Operational Carbon Emissions
Total Annual Carbon Emissions Carbon Use Intensity (Program-based) Carbon Use Intensity (User-Defined) Carbon Emissions per Occupant
2,052,000 136.8 136.8 41,040
183,000 12.2 12.2 3,660
kBtu / yr kBtu / sf / yr kBtu / sf / yr kBtu / occupant / yr Use ZeroTool designated EUI
kg-CO2e / yr kg-CO2e / sf / yr kg-CO2e / sf / yr kg-CO2e / occupant / yr User-Defined Benchmark Source
Electric Lighting
Lighting Power Density Lighting Power Density (User-Defined)
1.22 1.22
W / sf W / sf User-Defined Benchmark Source
This first page assigns benchmarks based on building-specific, national data for the project to be compared against.
If a user-defined benchmark is present, the national benchmarks will be overridden.