Umatilla PD Presentation_FLAT

Page 1


• Structural framing study of a typical bay (~30' x ~50')

• For each structural framing material/system:

- Pros and Cons

- Relative pricing

- Relative embodied CO2 impact

Umatilla Police Station Project Number: 2220303.00 May

Option 1 - Redbuilt Roof Trusses w/ Wood Roof

• Trusses comprised of wood chords with tube steel webs

• Trusses spaced @ 5'-0" on center

• Plywood roof with subpurlins between trusses

• Wood stud bearing walls

WOOD BEARING SHEAR WALLS, TYP

Option 2 - Open Web Steel Joists w/ Metal Roof Deck

• Standard open web steel joists

• Trusses spaced @ ~7'-0"

• Metal roof deck

• Steel tube columns at grid intersections

STEEL TUBE COLUMNS WHERE OCCURS

JOIST GIRDERS WHERE OCCURS

• Stacked wide flange framing at clerestory METAL STUD WITH WOOD SHEATHING

STACKED WIDE FLANGE BEAMS AT CLERESTORY GRID

METAL STUD WITH WOOD SHEATHING INFILL SHEAR WALLS BETWEEN CLERESTORY WHERE OCCURS

Option 3 - Open Web Steel Joists w/ Wood Roof

• Standard open web steel joists

• Trusses spaced @ 10'-0"

• Plywood roof with subpurlins between trusses

• Steel tube columns at grid intersections

• Stacked wide flange framing at clerestory

PLYWOOD SHEATHING

STEEL TUBE COLUMNS WHERE OCCURS 2x6 SUBPURLINS @ 2' OC

JOIST GIRDERS WHERE OCCURS

WOOD OR METAL STUD WITH WOOD SHEATING NON-BEARING SHEAR WALLS, TYP

WOOD OR METAL STUD WITH WOOD SHEATHING INFILL SHEAR WALLS BETWEEN CLERESTORY WHERE OCCURS STACKED WIDE FLANGE BEAMS AT CLERESTORY GRID

Option 4 - Glulam Framing w/ Wood Roof

• Glulam beams/girders

• Beams spaced @ ~8'-0"

• Plywood roof with subpurlins between beams

• Steel tube columns as occurs

• Wood posts within wood sheathed walls at glulam beams

POSTS WITHIN SHEAR WALL AT GLULAM BEAMS

STEEL TUBE COLUMNS WHERE OCCURS

GLB5-1/8x31-1/2

GLB3-1/2x16

GLB3-1/2x16

WOOD NON-BEARING SHEAR WALLS, TYP

8x6 POSTS WITHIN INTERIOR SHEAR WALL AT GLULAM BEAMS

6x6
2x6 SUBPURLINS @ 2' OC
PLYWOOD SHEATHING

Option 5 - Glulam Framing w/ CLT Roof

• Glulam beams between bearing walls

• Cross Laminated Timber (CLT) roof deck

• Wood stud bearing walls

• Steel tube columns as occurs

175E CLT PANELS, TYP

WOOD BEARING SHEAR WALLS, TYP

STEEL TUBE COLUMNS WHERE OCCURS

Option 6 - Glulam Framing w/ T&G Deck

• Glulam beams/girders

• Beams spaced @ ~8'-0"

• Tongue & Groove (T&G) roof decking w/ plywood sheathing

• Steel tube columns as occurs

• Wood posts within wood sheathed walls at glulam beams

6x6 POSTS WITHIN SHEAR WALL AT GLULAM BEAMS

PLYWOOD SHEATHING

2x4 T&G DECKING

STEEL TUBE COLUMNS WHERE OCCURS

GLB5-1/8x33

GLB3-1/2x16

GLB3-1/2x16

WOOD NON-BEARING SHEAR WALLS, TYP

8x6 POSTS WITHIN INTERIOR SHEAR WALL AT GLULAM BEAMS