• Structural framing study of a typical bay (~30' x ~50')
• For each structural framing material/system:
- Pros and Cons
- Relative pricing
- Relative embodied CO2 impact
Umatilla Police Station Project Number: 2220303.00 May











• Structural framing study of a typical bay (~30' x ~50')
• For each structural framing material/system:
- Pros and Cons
- Relative pricing
- Relative embodied CO2 impact
Umatilla Police Station Project Number: 2220303.00 May
• Trusses comprised of wood chords with tube steel webs
• Trusses spaced @ 5'-0" on center
• Plywood roof with subpurlins between trusses
• Wood stud bearing walls
WOOD BEARING SHEAR WALLS, TYP
• Standard open web steel joists
• Trusses spaced @ ~7'-0"
• Metal roof deck
• Steel tube columns at grid intersections
STEEL TUBE COLUMNS WHERE OCCURS
JOIST GIRDERS WHERE OCCURS
• Stacked wide flange framing at clerestory METAL STUD WITH WOOD SHEATHING
STACKED WIDE FLANGE BEAMS AT CLERESTORY GRID
METAL STUD WITH WOOD SHEATHING INFILL SHEAR WALLS BETWEEN CLERESTORY WHERE OCCURS
• Standard open web steel joists
• Trusses spaced @ 10'-0"
• Plywood roof with subpurlins between trusses
• Steel tube columns at grid intersections
• Stacked wide flange framing at clerestory
PLYWOOD SHEATHING
STEEL TUBE COLUMNS WHERE OCCURS 2x6 SUBPURLINS @ 2' OC
JOIST GIRDERS WHERE OCCURS
WOOD OR METAL STUD WITH WOOD SHEATING NON-BEARING SHEAR WALLS, TYP
WOOD OR METAL STUD WITH WOOD SHEATHING INFILL SHEAR WALLS BETWEEN CLERESTORY WHERE OCCURS STACKED WIDE FLANGE BEAMS AT CLERESTORY GRID
• Glulam beams/girders
• Beams spaced @ ~8'-0"
• Plywood roof with subpurlins between beams
• Steel tube columns as occurs
• Wood posts within wood sheathed walls at glulam beams
POSTS WITHIN SHEAR WALL AT GLULAM BEAMS
STEEL TUBE COLUMNS WHERE OCCURS
GLB5-1/8x31-1/2
GLB3-1/2x16
GLB3-1/2x16
WOOD NON-BEARING SHEAR WALLS, TYP
8x6 POSTS WITHIN INTERIOR SHEAR WALL AT GLULAM BEAMS
• Glulam beams between bearing walls
• Cross Laminated Timber (CLT) roof deck
• Wood stud bearing walls
• Steel tube columns as occurs
WOOD BEARING SHEAR WALLS, TYP
• Glulam beams/girders
• Beams spaced @ ~8'-0"
• Tongue & Groove (T&G) roof decking w/ plywood sheathing
• Steel tube columns as occurs
• Wood posts within wood sheathed walls at glulam beams
6x6 POSTS WITHIN SHEAR WALL AT GLULAM BEAMS
PLYWOOD SHEATHING
2x4 T&G DECKING
STEEL TUBE COLUMNS WHERE OCCURS
GLB5-1/8x33
GLB3-1/2x16
GLB3-1/2x16
WOOD NON-BEARING SHEAR WALLS, TYP
8x6 POSTS WITHIN INTERIOR SHEAR WALL AT GLULAM BEAMS