MEISHA GUILD DETAILING STUDIO PORTFOLIO NYCCT 2014
WOOD SIDING (OR ALUM/VINYL W/SLOTS) (RAIN SCREEN)
GWB 7/8" METAL FURRING CHANNELS E 16" O. C/MAX
AIR GAP W/VERT. WOOD GROUNDS 3/8" MIN.
VAPOR RETARDER (10 MIL POLYETALENE)
BLDG PAPER (DRAINAGE SURFACE)
GWB (AIR BARRIER) 6" BATT INSUL.
EXT. SHEATHING (FIBER BOARD-ASPHALT IMPREGNATED OR EXT. GWB)
2X6 STUDS @ 16" O.C. MAX SEAL AIR BARRIER AT STUDS-TYPICAL
AIR / VAPOR MOVEMENT
AIR & VAPOR PRESSURE
AIR & PAPER PERSSURE DRYING
OUTSIDE
INSIDE
COLD CLIMATE WALL DETAIL 1 1/2" = 1'-0"
Notes:
-BUILDING PAPER ACTS AS DRAINAGE SURFACE -SEAL AIR BARRIER (GWB) AT STUDS -MECH REDUCE AIR PRESSURE ON INTERIOR -INSTALL VAPOR RETARDER ON WARMSIDE -AIR GAP ACTS AS DRAINAGE SPACE
WOOD SIDING (OR ALUM VINYL W/ SLOTS) (RAIN SCREEN)
GWB
BATT INSUL. 3/8" MIN WOOD FURRING STRIPS @ 16" O.C. MAX (DRAINAGE SPACE)
6" WD STUDS @ 16" O. C. MAX
BLDG PAPER (#20-25) (DRAINAGE SURFACE)
10 MIL POLYETHYLENE (VAPOR RETARDER)
5/8" EXT. SHEATHING CASPHALT IMPREGNATED FIBERRD-EXT.GWB (AIR BARRIER)
SEAL AIR BARRIER/V.R AT STUDS-TYP.
AIR / VAPOR MOVEMENT
AIR & PAPER PERSSURE
AIR & VAPOR PRESSURE DRYING
OUTSIDE
HOT CLIMATE WALL DETAIL 1 1/2" = 1'-0"
Notes:
-BLDG PAPER ACTS AS AIR BARRIER -SEAL AIR BARRIER AT ALL STUDS -TAPE AND SEAL ALL JOINTS OF AIR BARRIER -INSTALL AIR AND VAPOR BARRIER ON WARMSIDE -VAPOR RETARDER COULD ALSO ACT AS DRAINAGE SURFACE IF IT IS WATERPROOFED
INSIDE
WOOD SIDING (OR ALUM/VINYL W/SLOTS) (RAIN SCREEN)
GWB A.B.
BATT INSUL. 3/8" MIN WOOD FURRING STRIPS @ 16" O.C. MAX (DRAINAGE SPACE)
6" WD STUDS @ 16" O. C. MAX
7/8"MTC. FURRING CHANMELS@16" O.C. BLDG PAPER (#20-25) (DRAINAGE SURFACE)
5/8"GWB
5/8" EXT. SHEATHING CASPHALT IMPREGNATED FIBERRD-EXT.GWB (AIR BARRIER)
OUTSIDE
SEAL AIR BARRIER/V.R AT STUDS-TYP.
DRYING
MIXED CLIMATE WALL DETAIL 1 1/2" = 1'-0" (FLOW THRU WALL)
Notes:
-RIGID INSULATION SHEATHING ACTS AS AIR BARRIER -PROPERLY TAPE AND SEAL ALL JOINTS IN RIGID INSULATION -PROVIDE AIR BARRIERS ON BOTH SIDES OF THE WALL -SEAL AIR BARRIER AT ALL STUDS AND PLATES -VAPOR BARRIER IN THE MIDDLE OF THE WALL -ALLOW FOR DRYING NEITHER DIRECTION BY USING PERMIABLE MATERIAL
INSIDE
WOOD SIDING (OR ALUM VINYL W/ SLOTS) (RAIN SCREEN)
GWB (AIR BARRIER TAPE & SEAL ALL JOINTS TYP.) BATT INSUL. 6" WD STUDS @ 16" O. C. MAX
3/8" MIN WOOD FURRING STRIPS @ 16" O.C. MAX (DRAINAGE SPACE)
10 MIL POYETHYLENE (VAPOR BARRIER)
7/8"MTC. FURRING CHANMELS@16" O.C.
BLDG PAPER (#20-25) (DRAINAGE SURFACE)
5/8" GWB
1 1/2" RIGID INSULL SHEATHING (AIR BARRIER)
SEAL AIR BARRIER/ V. R. AT STUDS - TYP
DRYING
MIXED CLIMATE WALL DETAIL 1 1/2" = 1'-0" (MIDDLE OF WALL VAPOR RETARDER)
Notes:
-SEAL AIR BARRIER IN ALL SLOTS AND PLACE VAPOR BARRIER IN MIDDLE OF WALL (FOR DRYING IN EITHER DIRECTION)
GWB
1" STUCCO OVERMETAL LATT (FACE SEAL)
MASONRY (STORAGE RESERVIOR)
FURRING STRIPS
RIGID INSULATION (2” MIN) SEMI-PERMIABLE
VAPOR RETARDER (2” MIN)
FACE SEALED BARRIER WALL W/ STORAGE RESERVIOR 1 1/2" = 1'-0"
(BEST INREGIONS WITH MODERATE RAINFALL 2O” - 40” ANUALLY)
Notes:
-ADD WATERPROOFING ADD MIXTURES ON STUCCO -MASONARY ACT AS WATER RESERVIOR ALLOWS THE WALL TO DRY TOWARDS THE INSIDE
1" STUCCO OVERMETAL LATT ( FAC E SEAL)
GWB
(VAPOR RETARDER) RIGID INSULATION (2” MIN) BATT INSULATION EXT. GWB EQC SHETHING
WOOD OR METAL STUDS @ 16" O.C. 6"
EXTERIOR INSULATING FINISH (EIF)
W.P. MEMBRANE 2 LAYERS
FACE SEALD BARRIER WALL W/O STORAGE RESSERVIOR 1 1/2" = 1'-0" BEST IN REGIONS OF LESS THAN 20” OF ANNUAL RAIN FALL)
Notes:
-ONLY RECOMENDED FOR LOW RAIN FALL REGIONS -NO WATER STORAGE CAPACITY -EIF IS WATER PERMIABLE
1" STUCCO OVERMETAL LATT (FACE SEAL)
RIGID INSULATION (2” MIN) (SEMI-PERMIABLE)
GWB
(VAPOR RETARDER)
BATT INSULATION AIR SPACE (DRAIN SPACE)
BLDG. PAPER #30 (DRAINAGE SURFACE)
WOOD OR METAL STUDS @ 16" O.C. 6"
EXT. GWB
WATER MANAGED WALL W/RAINSCREEN SYSTEMS 1 1/2" = 1'-0" (DRAINAGE SPACE & DRAINAGE SURFACE) (BEST IN REGIONS OF HIGH ANNUAL RAIN FALL 40”-60”)
Notes:
-AIR SPACE ACT AS CAPILARY BREAK -BEST IN REGIONS OF HIGH RAIN FALL -RAIN SCREEN HAS WEEP HOLES ON BOTTOM OF WALL FOUNDATION -AIR SPACE IS DRAINED TOWARD THE OUTSIDE AT BASE OF WALL -BUILDING PAPER ACTS AS DRAINAGE SURFACE.
1" BRICK VENEER (RAIN SCREEN W/ WEEP HOLES @ EA. FLOOR) GWB
AIR SPACE 1 1/2" MIN. (DRAINAGE SPACE) VAPOR RETARDER BLDG PAPER # 30 (DRAINAGE SURFACE)
6" BATT INSUL.
EXT. SHEATHING 3/4" EXT. PLYWD OR ASPHATT IMPR FIBERBD 6" STUDS SEAL AIR BARRIER AT STUDS-TYPICAL
WATER MANAGED WALL/ PRESSURE EQUALIZED RAINSCREEN SYSTEM 1 1/2" = 1'-0" PRESSURE MODIFIED SYS (PMS) DRAINAGE SPACE & DRAINAGE SURFACE
Notes:
-BRICK VENEER ACTS AS RAINSCREEN -THE AIR SPACE ACTS AS DRAINAGE SURFACE -THE AIRSPACE IS VENTED TO THE OUTSIDE TO ALLOW FOR PRESSURE EQUALIZATION ACROSS THE WALL
GRADE
NEGATIVE WATERPROOFING
REINF. CONC. FDTN WALL
DRAIN BOARD
WATER STOP-CONT. WATER PROOFING MEMBRANE
6" REINF.CONCRETE ON GRADE WATER PROOFING/VAPOR RETAROER MEMBRAINGUNDER SLAB/ FOOTING UP TO BASE OR FUTN. BASE
LAPPED MEMBRANES
CEMENT WASH 6" GRAVEL BASE FILTER FABRIC GRAVEL 4" DIA. DRAIN PIPE
FOUNDATION WALL/SLAB DETAIL 1 1/2" = 1'-0"
Notes:
-CONNECT FOOTING DRAIN PIPE TO STORM DRAIN -DRAIN PIPE MUST BE SLOPED -45 DEGREE CONC. WASH PREVENTS WATER FROM SITTING AT JOINT AND PENETRAITING BLDG.
14" REINF CONC. POTN WALL
PROPERTY LINE
NEGATIVE WATER PROOFING
SHEET PILING
2 1/2" METAL STUDS @ 16" O.C. MAX
DRAIN BOARD W/INTEGRAL DRAIN TUBES
2 1/2" BATT INSULATION W/PULL FACED VAPOR BARRIER 5/8" GWB
BLIND-SIDE WATERPROOFING MEMBRANE
10" REINF. CONC. PRESSURE SLAB 95 MIL-WATERPROOFING/VAPOR RETARDER (CAPILARY BREAK) UNDER SLAB & FOOTING
MEMBRANE OVERLAP W/MANUF. SEALANT
WATER STPS-CONT.
2'-0" DX 3'-6" W/REINF CONC. FOOTING
3" DRAIN PIPE TO SEPTIC TANK
4" PERFORATED FLEX PRING FABRIC WRATPED IN GRAVEL BASE TO SEPTIC TANK
FDTN/SLAB WATERPROOF DETAIL 1 1/2" = 1'-0" Notes:
-THE PRESSURE SLAB IS DESIGNED TO STAND THE HYDROSTATIC UPWARD PRESSURE FROM GROUND WATER -DRAIN PIPES UNDERNEATH THE SLAB IS DESIGNED TO RELIEVE THE FLOOR SLAB FROM HYDROSTATIC PRESSURE DIRECT ALL GROUND WATER TO A SUMP -WATER STOPS PREVENT WATER MOVEMENT AT CONCRETE JOINTS BETWEEN SLABS, FOOTING, AND CONCRETE WALLS -THE BLDG DEAD LOADS ARE USED TO HOLD DOWN THE PRESSURE SLAB -THE DRAIN BOARD DIRECTS ALL WATER AT PROPERTY LINE TO UNDERGROUND DRAIN PIPES -NEGATIVE WATERPROOFING ON THE INSIDE OF THE FOUNDATION WALL ACTS AS A LAST LINE OF WATER PROTECTION
PROPERY LINE 10" CMU NEGATIVE WATER PROOFING MORTAR NET-CONT. TYP.
VAPOR BARRIOR BLOCK-O-FLASH-TYP. RIGID INSULATION
GROUT
1" AIR GWB #5 REBAR @32" O.C. IN CELLS FILLED SOLID W/GROUNT-TYPICAL
SHEET PILING
GWB BLINDSIDE W.P. MEMBRANE
WATER STOP CONT.
NEGATIVE WATERPROOFING RIGID INSULATION
REINFORNCE CONCRETE FOUNDATION WALL
VAPOR BARRIOR GWB
SPLIT-SLAB FOUNDATION WALL W. P. DETAIL 1 1/2" = 1'-0"
Notes:
-#5 DOWELS @32” OC -MORTAR NET PROTECTS FLASHING FROM BEING CLOGED-PLACE ONE AT EVERY BLOCK -5/8” ACTS AS WATER RESERVOIR -2-1/2” RIGID INSUL. R-12,5 -IF NEW BLDG BREECHES 45 DEGREE ANGLE OF REPOSE, THE EXISTING BLDG MUST BE UNDER PINNED -TO AVOID UNDERPINNING, USE PILING W/ CORREGATED METAL.
4" FACEBRICK TED TO CMU @16" O.C. VERT. 2" AIR SPACE WEEP HOLES @ 24" O.C. STAGGERED # IS BLDG. PAPER (DRAINAGE SURFACE) BLOCK-O-FLASH THRU WALL METAL FLASHING CONT.
H20 MEM. CARRIED DOWN OVER BRICK SHELF & LAP OVER FDTN.WALL WATERPROOFING MEM. DRAIN BOARD
5/8" GWB 1 WOOD GROUNDS @16" O.C. MA. (UTLITY SPACE) 5/8" GWB SEAL AND TAPE ALL JOINTS CONT.(AIR BARRIER) 10 MIL POLYETHELENE VAPOR BARRIER ATTACHED TO CMU W/ AD JESIVE # 5 DOWELS @ 32" O.C. IN CMU CELLS FILLED W/ SOLID W/ GROUT
FILL GAP SOLID W/ GROUT 5/8" GWB 2 1/2" RIGID INSUL.W/ GROUT NEGATIVE WATERPROOFING
WATERSTOP-CONT.
14" REINF. CONC. FOOTING WALL
MEMBRANES OVERLAPPED W/ MANUFACTURED SEAL ANT
3" METAL STUDS @16" O.C. MAX. 10" REINF PREASSURE SLAB
CEMENT WASH REINF. CONC. FOOTING DRAIN PIPE CONNECTOR
95 MIL WATERPROOFING MEMBRANE/ VAPOR RETARDER UNDER SLAB FOOTING 3" DIAL DRAIN PIPE
TYP. WALL-FOUNDATION AND 1ST. FL. WALL DETAIL 1 " = 1'-0" Notes:
3 LAYERS OF 5/8" GWB W/ STAGGERED AND TAPED JOINTS
LAYERS 5/8" GWB
4" METAL STUDS @16" O.C.
NEOPRENE FILLER TOP & BOTTOM
2" AIR SPACE
ACCOUSTICAL SEALANT CONT.
3/8" GWB SILL CORNER BEAD CONT.
1/2" LAMINATED ACOUSTICAL GLASS
ALLUM. FRAME.
3/8" LAMINATED ACOUSTICAL GLASS SLOPED 1" FABRIC WRAPPED FOAM PANELS CONT.
5/8" GWB-3 LAYERS -TAPE SEAL & STAGGER ALL JOINTS
5/8" GWB-2 LAYERS -TAPE SEAL & STAGGER ALL JOINTS
4" FIBER GLASS SOUND ATTENUATION BATT FULL HEIGHT
ACOUSTICAL WINDOW WALL DETAIL 1 1/2" = 1'-0"
Notes:
-ACOUSTICAL SEALANT AROUND ALL FRAMES -SILICA GEL-ABSORBS THE MOISTURE AND PREVENTS FOG IN GLASS
ACOUSTICAL SEALANT CONT.
5/8” GWB-2 LAYERS -TAPE SEAL & STAGGER ALL JOINS
5/8” GWB-3LAYERS -TAPE SEAL & STAGGER ALL JOINTS
4” FIBER GLASS SOUND ATTENUATION BATT FULL HEIGHT
3-1/2” SOUND ATTENUATION BATT FULL HEIGHT
3-5/8” METAL STUD FRAME @ 12” OC MAX BRACED @ 1/4 POINTS VERTICAL
3-5/8” -22 GA METAL BASE RUNNER SET IN FULL BED OF ACOUSTICAL SEALANT
2” AIR SPACE CONT. 4” 22. GA METAL STUD FRAME 12” OC MAX BRACED 21/4 POINTS VERTICALLY
2-1/2” METAL STUD FRAME 22 GA @12” OC & BRACED @24” OC MAX
CARPET OVER FOAM PADDING 1/2” MIN
3-1/4” EXT PLYWOOD SHEATHING EXT. GWB 2 LAYERS -DENS SHIELD SHEATHING -STAGGER TAPE & SEAL ALL JOINTS 2X2X2 NEOPRENE PADS @12” OC GLUED TO CONC SLAB & PLYWOOD SHEATHING
1” THICK MINERAL WOOL
4” 22. GA METAL RUNNER TOPS BOTTOM SET IN FULL BED OF ACOUSTICAL SEALANT
FLOATING FLOOR ACCOUSTICAL DETAIL 1 " = 1'-0"
Notes:
2-1/2” SOUND ATTENUATION BATT FULL LENGTH & WIDTH
METAL DOWEL SET IN MORTARW/ 3” MIN EMBEDMENT IN COPING STONE
NEW PRECAST CONC. COPING W/ INTEGRATED DRIP EDGE EACH END
#5 REBAR NON CORROSIVE BENT AND WELDED TO THE TOP OF THE EXISTING STEEL BEAM @ 48” OC MIN
DRIP EDGE
NEW SAWTOOTH COPPER FLASHING SET IN FULL BED OF MORTAR
NEW WALL TIE WITH PENCIL ROD @12” OC & EXPANSION BOLTED INTO BRICK
NEW LADDER TYPE JOINT REINF. @16” OC. VERTICALLY FABRIC COATED METAL FLASHING IN FULL BED OF MASTIC
WEEP VENT NEW 2 PIECE COPPER COUNTERFLASHING W/ UPTURN REAR LEG
NEW FACEBRICKS 3 WYTHES
EXISTING BRICK TO REMAIN
NEW PMETAL LED WEDGE @12” OC WITH PENCIL ROD
SEALANT CONT.
WEEP HOLES @ 24” OC
NEW PROOFING MEMBRANE
NEW RIGID INSUL.& CANT STRIP
BRICK TIE WELDED TO STEEL BEAM @12” OC W/ PENCIL ROD
NEW STEEL LINTEL ANGLE CONT. AS REQUIRED
EXISTING STEEL BEAM WEEP HOLES @ 24” OC
RUBBERIZED ASPHALT WATER PROOFING MEMBRANE IN FULL BED OF MASTIC
EXISTING CONC. ROOF DECK
EXISTING ALUMN. WINDOW SEALANT & BACKER ROD
EXISTING WATERPRROFING PARAPET DETAIL 1 " = 1'-0"
Notes: