VOLUNTEER WORKSTATION STORAGE

MECHANICAL

B

B

B

B

1/100

1/100

1/100

1/100

286 SF

136 SF

36 SF

1

1

FLEX SPACE

1

3

1

PHONE CLOSET

BATHROOM

MARKETING

BREAKROOM

B

B

B

A2

B

45 SF

1/100

1/100

1/100

1/200

1/100

1

44 SF

27 SF

70 SF

176 SF

26 SF

1

1

20

1

DEVELOPMENT

1

1

1

1

1

1

1

1 6' - 6"

L.H.M.S.G DESIGN

4' - 11 1/2"

2 4

MAX PATH OF TRAVEL 49’-7”<200’-0”

1' - 8"

3 1

4”

FEC

91’-

5' - 1"

FEC

COMMON PATH OF TRAVEL 22’-6”<75’-0”

TOILET TISSUE 19" FROM FLOOR

2' - 7"

VANITY 40" FROM FLOOR 9' - 0"

1

SOAP DISP. 40" FROM FLOOR

3

DEVELOPMENT

STORAGE

SPECIAL PROGRAM

DIRECTOR OFFICE

OFFICE/ CONFERENCE

B

B

1/100

B

S

B

B

B

1/100

1/100

33 SF

1/100

1/300

1/100

1/100

1/100

308 SF

48 SF

1

32 SF

28 SF

61 SF

94 SF

177 SF

4

1

1

1

1

1

2

1

1

1

1

1

HAND DRYER 36" FROM FLOOR

3' - 0"

1

3' - 2"

1

1

60" MIN DIAM CLEARANCE

3' - 5"

B

PRINTER/COPY

CONFERENCE / CLASSROOM

SINK HEIGHT 34"

5' - 1 5/8"

SPECIAL PROGRAM

12' - 2"

30"x48" CLEARANCE

2' - 8 3/8"

2' - 3 31/32" 3' - 0" 0' - 9"

HARD CONSULT ROOM

PROGRAM ROOM

LIBRARY

B 1/ 15

A3 1/ 50

B 1/100

184 SF 13 1

244 SF 5 1

76 SF 1 1

BOUTIQUE

BATHROOM

B 1/150

B 1/100

150 SF 1 2

49 SF 1 1

BATHROOM B 1/100 ---

69 SF 1 1

STORAGE S 1/300 41 SF 1 1

1. OCCUPANT LOAD PER CBC CHAPTER 10 TABLE 1004.1.1

WAITING AREA

COMMON PATH OF TRAVEL 22’-10”<75’-0”

2

4

2' - 6"

1 91 ' -

15 /1

B 1/ 15 64 SF 5 1

1 4

6"

ER

89’-4”

MAX PATH OF TRAVEL 64’-9”< 200’-0”

FEC

ER

OCCUPANCY TYPE WAITING/RECEPTION AREA CONSULT ROOMS INFO DESKS/CUBICLES/OFFICES LIBRARY BOUTIQUE WORK/MAIL/COPY ROOM FLEX SPACE PROGRAM ROOM CONFERENCE BREAKROOM BATHROOM STORAGE PHONE CLOSET/MECHANICAL

TOTAL USE AREA 192 SQ FT 175 SQ FT 610 SQ FT 244 SQ FT 150 SQ FT 155 SQ FT 286 SQ FT 184 SQ FT 485 SQ FT 176 SQ FT 145 SQ FT 77 SQ FT 62 SQ FT

% USE OF AREA 6 6 20 8 5 5 9 6 16 6 5 6 2

LOAD FACTOR 1:15 1:100 1:100 1:100 1:50 1:100 1:100 1:15 1:100 1:200 1:100 1:300 1:100

OCCUPANCY LOAD 7 OCC 2 OCC 10 OCC 5 OCC 2 OCC 2 OCC 3 OCC 13 OCC 6 OCC 20 OCC 3 OCC 3 OCC 2 OCC

2. NUMBER OF EXITS REQUIRED PER CBC SECTION 1015.1 2

3

COFFEE BAR

VOLUNTEER COORDINATOR

RECEPTION DESK

B 1/100

B 1/100

B 1/100

30 SF 1 1

62 SF 1 1

98 SF 1 1

PROJECT INFORMATION BUILDING: CANCER REHIBILITATION CENTER ADDRESS: 986 FORREST LANE PALO ALTO, CA 95110 NUMBER OF STORIES: 2 CONSTRUCTION TYPE: TYPE 5B OCCUPANCY TYPE (S): B FIRE PROTECTION: NO SPRINKLERS FLOOR AREA OF WORK: 5,370 SEPARATION OF MIXED OCCUPANCIES: NO SEPARATION NEEDED INCIDENTAL USE: NONE ALLOWABLE BUILDING AREA: 9,000 SF ALLOWABLE BUILDING HEIGHT: 40 FEET FIRE RESISTANCE OF BUILDING ELEMENTS: STRUCTURAL FRAME: 0 HOURS EXTERIOR BEARING WALLS: 0 HOURS INTERIOR BEARING WALLS: 0 HOURS INTERIOR PARTITIONS: 0 HOURS FLOOR CONSTRUCTION: 0 HOURS ROOF CONSTRUCTION: 0 HOURS FIRE DOOR ASSEMBLY RATING FOR: FIRE BARRIERS: 2 HOURS FIRE PARTITIONS: 1 HOUR PROTECTED FIRE WINDOW ASSEMBLY RATING FOR: FIRE BARRIERS: NOT PERMITTED FIRE PARTITIONS: 0.5 HOUR INTERIOR FINISH CLASS REQUIREMENTS: EXIT ENCLOSURES & PASSAGEWAYS: CLASS A CORRIDORS: CLASS B ROOMS & ENCLOSED SPACES: CLASS C EGRESS WIDTH – DOORS: REQUIRED: 32" ACTUAL: 36" EGRESS WIDTH – STAIRS: REQUIRED: 44" ACTUAL: 47" MAXIMUM EXIT ACCESS TRAVEL DISTANCE: REQUIRED: 200' ACTUAL: 70' MAXIMUM COMMON PATH OF TRAVEL DISTANCE: REQUIRED: 100' ACTUAL:90' MAXIMUM DEAD END LENGTH: REQUIRED: 50' ACTUAL: 22'

PROGRAM ASSOCIATE B 1/100 40 SF 1 1

SOFT CONSULT ROOM

WORK ROOM

DIRECTOR OF PROGRAMS OFFICE

B 1/100

B 1/100

B 1/100

99 SF 1 1

107 SF 2 1

129 SF 1 2

3. EXIT WIDTH PER CBC SECTION 1005 CALCULATED ACTUAL DOORS 0.2 X 89 OCC = 18" 78" STAIRS 0.3 X 89 OCC = 27" 84"

SHEET NOTES 1. MINIMUM PATH WIDTH SHALL BE 36 INCHES. (CBC- 2013 11B 403.5.1) 2. MINIMUM ACCESSIBLE PATH WIDTH SHALL BE 60 INCHES. (CBC-2013 11B 403.5.1) 3. AN ACCESSIBLE CLEAR FLOOR OR GROUND SPACE SHALL BE A MINIMUM OF 30 INCHES BY 48 INCHES. (CBC- 2013 11B-305.3) 4. FLOOR OR GROUND SURFACES CHANGES IN LEVEL ARE NOT PERMITTED, UNLESS WITH THE EXCEPTION OF SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED. (CBC-2013 11B- 305.2) 5. DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES MINIMUM. (CBC-2013 11B- 404.2.3) 6. MANEUVERING CLEARANCES SHALL EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED LATCH SIDE OR HINGE SIDE CLEARANCE. (CBC-2013 11B- 404.2.4) 7. OPERABLE PARTS SUCH AS HARDWARE ON DOORS SHALL BE 34 INCHES MINIMUM AND 44 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. (CBC- 2013 11B- 404.2.7) 8. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE OTHER THAN FIRE DOORS SUCH AS INTERIOR HINGED DOORS AND GATES SHALL BE A MAXIMUM OF 5 POUNDS. (CBC- 2013 11B- 404.2.9) 9. PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN THE FOLLOWING GROUP OCCUPANCIES, A, B, E, F, H, I, L, M, R-1, R-2, R-2.1, R.3.1, R-4, AND S (CBC- 2013 [F]- 906.1) 10. PORTABLE FIRE EXTINGUISHERS SHALL BE LOCATED IN CONSPICUOUS AND READILY ACCESSIBLE LOCATIONS. (CBC- 2013 [F] 906.5)

LEGENDS 13. TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS. -(CBC- 2013 11B- 703.4.1)

-

POINT OF EGRESS

FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED

B

14. VISUAL CHARACTERS SHALL BE 40 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND. (CBC- 2013 11B-703.5.6) 15. ALL STEPS ON A FLIGHT OF STAIRS SHALL HAVE RAISERS WITH A MINIMUM OF 4 INCHES AND MAXIMUM OF 7 INCHES HIGH. TREADS SHALL BE A MINIMUM OF 11 INCHES DEEP MINIMUM. (CBC- 2013 11B- 504.2)

FEC

16. HANDRAILS SHALL BE 34 INCHES MINIMUM AND 38 INCHES MAXIMUM VERTICALLY ABOVE WALKING SURFACES, STAIR NOSINGS, AND RAMP¬ SURFACES.(CBC- 2013 11B- 505.4) 17. THE REQUIREMENTS FOR ACCESSIBILITY UPGRADE FOR A PROJECT WITH A LIMITED BUDGET OF $50,000 SHALL BE LIMITED TO $10,000, WHICH IS 20 PERCENT OF THE ADJUSTED CONSTRUCTION COST OF ALTERATIONS, STRUCTURAL REPAIRS OR ADDITIONS. (CBC- 2013 11B- 202.4 EXCEPTION 8)

FIRE EXTINGUISHER CABINET

OCCUPANCY TYPE

1/100

OCCUPANCY LOAD FACTOR

260 SF

SQUARE FOOTAGE NUMBER OFDOORS/ OCCUPANCY LOAD

1

12

CODE PLAN

ILLUMINATED EXIT SIGN WITH DIRECTIONAL ARROWS (WHERE OCCURS)

ER

PROVIDE TACTILE EXIT SIGNAGE PER CBC SECTION 1117B.5.1, #AT THESE LOVATIONS WITH THE FOLLOWING WORD(S) (CBC 1011.3.4): "EXIT ROUTE"

EXIT SIGN NOTE: FOR EXIT SIGNAGE PER CBC SECTION 1117B.5.1, #2 AND CBC 1011.3.4, SIGNAGE SIZE AND COLORE PER CLIENT STANDARDS

A02

KEYNOTES 1

EXISTING RATING CORRIDOR

2

Project Number: Date:

PATH OF TRAVEL

11. PORTABLE FIRE EXTINGUISHERS SHALL NOT BE OBSTRUCTED OR OBSCURED FROM VIEW. (CBC- 2013 [F] 906.6) 12. SIGNS ARE REQUIRED TO HAVE CHARACTERISTICS OF BOTH VISUAL AND TACTILE. (CBC- 2013 11B- 703.1)

OFFICE

EXISTING RATING STAIRWELLS

Drawn By: Checked By:

MAXIMUM PATH OF TRAVEL

COMMON PATH OF TRAVEL

3

EXISTING DOORS WITH PANIC HARDWARE

4

EXISTING ACCESSIBLE RESTROOM Scale

ASSIGNMNET 4 MAY 19, 2014 LAUREN, SUMMER, HENRY, GINA,MELISSA MORANA MEDVED

As indicated


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.