Museum of liverpool case study

Page 1

Case study - Museums

CHP powers major savings at sustainable new museum Museum of Liverpool, UK Four CHP units have been installed to provide

Liverpool’s famous waterfront. The installation was

efficient generation at the largest newly-built national completed ahead of the museum’s opening in July museum in the UK for more than a hundred years.

2011. ENER-G will also operate and maintain the plant for 17 years.

The prestigious £72 million Museum of Liverpool has installed an advanced combined heat and

The CHP system is split between a plant room in the

power (CHP) system, guaranteeing annual energy

new building and the historic Great Western Railway

savings of more than £500,000.

(GWR) Goods Shed on Liverpool’s picturesque waterfront. ENER-G is converting the Goods Shed

The ‘trigeneration’ technology, which

into a state-of-the-art energy centre with

creates highly efficient heat, electricity and cooling,

sophisticated remote monitoring and diagnostic

will also reduce carbon emissions by 884 tonnes

facilities.

each year – equivalent to the environmental benefit of taking 295 cars off the road.

ENER-G has designed and manufactured two 385kWe bio-diesel CHP units, two 768kWe natural

ENER-G was commissioned by National Museums

gas CHP systems and installed two 850kWe boilers,

Liverpool (NML) to design and install the new CHP

an 1000kWe absorption chiller and a 998kWe

system at the Mann Island site – part of the famous

conventional compression chiller which will serve all

Pier Head at the core of the World Heritage Site on

the new museum’s energy needs.

ENER-G Combined Power Limited


The benefits of CHP in the Arts and Culture sector:

 Offers financial savings over conventional energy supply

 Avoids Climate Change Levy  Primary energy savings deliver lower energy bills

 Higher efficiency offers reduced greenhouse gas emissions offsetting the impact of the Carbon Reduction Commitment

 Greater security of supply and plentiful hot water

 Flexible procurement options  Zero CAPEX required  VAT savings  Incorporate Enhanced Capital One of the ENER-G 768kWe Units at Liverpool Museum

Allowances otherwise denied by the public sector

Challenges faced by ENER-G included

The GWR Building housing the CHP

preserving the GWR building exterior in

plant will also become an educational

line with planning conditions as the site

resource in its own right with a small

is part of a protected view and designing

visitor facility where groups can gain an

About ENER-G

the energy centre to operate

understanding of the technology and its

ENER-G develops, delivers and

independently of the utility electrical

contribution to the museum’s

finances sustainable energy solutions

supply.

sustainability.

and technologies on a business to

The CHP system generates electricity

The complex energy facilities project,

and recovers the majority of the heat

“one-stop-shop‟ for all commercial and

which was funded by the Co-operative

created in the process. In conventional

industrial energy requirements, from

bank was awarded the Combined Heat

power stations this heat is simply wasted

combined heat and power (CHP),

and Power Association’s Innovation

into the atmosphere through power

renewable electricity generation from

Award for 2009 is helping NML boost

station cooling towers, much energy is

biogas, heat pump technologies,

both its cost and carbon performance.

efficient lighting, controls, metering and

 Possible grant funding

business basis worldwide. We offer a

also lost along the many miles of

data solutions and energy from waste.

electrical distribution cables needed to

The museum has been designed to

bring the power to site. Instead, by using

replace the former Museum of

For further details contact us:

CHP to generate electricity on site the

Liverpool Life. It provides 8,000 square

heat is used to provide heating and hot

metres of public space across three

water for the museum in the winter, and

floors and demonstrates Liverpool’s

air conditioning and chilled water

unique contribution to the world. It

via the absorption cooling system in the

showcases popular culture while

ENER-G Combined Power Ltd ENER-G House Daniel Adamson Road Manchester M50 1DT

summer months. The utility grid supply

tackling social, historical and

Tel: +44 (0)161 745 7450

will provide additional back up, if

contemporary issues.

Fax: +44 (0)161 745 7457

required.

chp@energ.co.uk www.energ.co.uk

ENER-G PLC ENER-G House Daniel Adamson Road Salford Manchester M50 1DT T: +44 (0)161 745 7450 F: +44 (0)161 745 7457 E: info@energ.co.uk W: www.energ.co.uk


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.