MYSON
Design Radiators Brochure & Technical Guide
heatingthroughinnovation.
02
Contents
COLUMN.
DÉCOR.
Contents
NEW
NEW
Introduction
04
COLUMN Range
06
Technical Information
08
Sizes and Outputs
10
General Specifications
12
Colour Board
13
Electric COLUMN
22
DÉCOR Range
14
Technical Information
16
Sizes and Outputs
18
General Specifications
20
Colour Board
21
Electric DÉCOR
22
03
04
I n t ro d u c t i o n
Join the design
revolution!
I n t ro d u c t i o n
In recent years, there has been a revolution in attitude towards radiators. Previously perceived as a purely functional item that ideally needs to disappear into the background and not be seen at all, a radiator is now increasingly being viewed as a stylish feature and upfront, focal point within a room. The MYSON COLUMN and DÉCOR ranges of design radiators have been at the very forefront of this trend since its beginning. They have played a leading role in helping to turn the humble radiator into a treasured decorative addition to a home. COLUMN and DÉCOR radiators are produced in both hydronic and electric versions and with an unbeatable choice of heights, lengths and colours available, there is a COLUMN or DÉCOR radiator to suit the decorative needs of every room. Take a little time to browse the many options available in this brochure and discover which ones are right for you. By installing a COLUMN or DÉCOR radiator into your home, you too can join the design revolution!
05
06
COLUMN Range
Now Available in Electric please see page 22 for more information
COLUMN Vertical.
COLUMN Range
COLUMN Range Looking to add an individual, stylish feature to your rooms? The MYSON COLUMN range has turned the humble radiator into a focal point and created a selection of new interior design possibilities for you. The proportions, scale and detailing of the MYSON COLUMN combine to give a symmetry and elegance that feels just right. Each unit is manufactured using the very latest, unique laser welding technology to create a radiator range of the highest quality, with a paint finish that is second to none. There is a colour, size and column configuration to suit every situation. COLUMN radiators are ideal for a variety of domestic or commercial uses.
COLUMN Bench Seat.
COLUMN Horizontal.
07
08
C O L U M N Te c h n i c a l I n f o r m a t i o n
Fixing Brackets (supplied with every radiator) - Wall Brackets 50
30
16
20
10.5
6
14
5 6.5
8.5
18
59
6
83
20.5 14
4.5 34.5 3.6 17
15
12
20
Radiator Brackets A (see table below)
19 32.5
62
Ensure tight fit here
11
13
Radiator Bracket 25 Angle Wall Bracket
11.5
20
11
30
Wall & Bracket
Wall Bracket & Radiator Bracket
Wall & Radiator
20mm
11mm
30mm
11mm
A = Distance between Wall & Centre
2 column
3 column
4 column
31mm
62.5
81.5
100.5
41mm
72.5
91.5
110.5
insert
Connections All MYSON COLUMN radiators are fitted with 4 x 1/2 inch BSP connections.
blue. It is important that the water inlet is connected to the tapping identified in red.
Radiators include plug and vent.
N.B. The radiator is suitable for the use of BBOE (Bottom Bottom Opposite End), TBSE (Top Bottom Same End) and TBOE (Top Bottom Opposite End) connections. TTOE (Top Top Opposite End) connections cannot be used.
Radiators are manufactured with an internal baffle. The tapping with the baffle is identified with a red plastic cap, all others being
C O L U M N Te c h n i c a l I n f o r m a t i o n
Fixing Brackets - Clamped Floor Bracket FK 8
10
Complete system for free-standing radiators, from 2-6 column up to 1000mm height. Painted to RAL 9016.
30
Comprises;
26 20
40
180-300mm
120
26
- 3mm thick base-plate fixing for either finished or unfinished floor
60 100
Clamped Floor Bracket FK
Order Code
Dimensions of base-plate for Clamped Floor Bracket FK
For 2-6 Column Rads.
FK1021
Base-Plate Cover
COVERFK
(
= base-plate cover) For use with 2-6 column radiators
Two-part cover for base-plate in white plastic 106 x 128mm
Floor Bracket SK Complete system for free-standing radiators, from 2-6 column up to 1000mm height. Painted to RAL 9016. Comprises; Two-part cover for base-plate in white plastic 110 x 135mm
104
75
8
91
116
Dimensions of base-plate for Floor Bracket SK
Operating Pressures Every MYSON COLUMN radiator is tested to a pressure of 13 bar (188.5 psi) and is suitable for a working pressure of up to 10 bar (145 psi).
- 3mm thick base-plate for fixing to either finished or unfinished floor - upright support 35 x 10 x 1.5mm, fixing set with adjustable bracket, security fixing, anti-vibration insert - adjustable bottom support with spacer and security fixing, anti-vibration insert, white plastic end stop for top of upright. Height of Upright
Height of Radiator
Order Code
460
300
SK20046
610
450
SK20061
760
600
SK20076
910
750
SK20091
Base-Plate Cover
COVERSK
09
10
COLUMN Sizes & Outputs
63 mm
101 mm
139 mm
2 COLUMN
3 COLUMN
4 COLUMN
2 COLUMN Length (mm - inches)
No. of Sections
Output (watts)
Output (Btu/h)
Order Code
Height 450 mm
600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72
12 16 20 24 28 36
435 580 725 870 1015 1305
1485 1980 2474 2969 3464 4454
12 SEC 2045 16 SEC 2045 20 SEC 2045 24 SEC 2045 28 SEC 2045 36 SEC 2045
Height 600 mm
600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55
12 16 20 24 28
564 752 940 1128 1317
1925 2567 3209 3850 4492
12 SEC 2060 16 SEC 2060 20 SEC 2060 24 SEC 2060 28 SEC 2060
300 - 12 400 - 16 500 - 20 600 - 24 750 - 30
6 8 10 12 15
881 1175 1468 1762 2202
3006 4008 5010 6012 7515
6 SEC 2200 8 SEC 2200 10 SEC 2200 12 SEC 2200 15 SEC 2200
Length (mm - inches)
No. of Sections
Output (watts)
Output (Btu/h)
Order Code
Height 300 mm
800 - 32 1000 - 40 1400 - 55 1800 - 71
16 20 28 36
566 708 991 1274
1933 2416 3382 4348
16 SEC 3030 20 SEC 3030 28 SEC 3030 36 SEC 3030
Height 450 mm
600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72
12 16 20 24 28 36
606 808 1010 1212 1414 1818
2068 2757 3446 4135 4825 6203
12 SEC 3045 16 SEC 3045 20 SEC 3045 24 SEC 3045 28 SEC 3045 36 SEC 3045
Height 600 mm
600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55
12 16 20 24 28
781 1042 1302 1562 1823
2665 3554 4442 5331 6219
12 SEC 3060 16 SEC 3060 20 SEC 3060 24 SEC 3060 28 SEC 3060
Height 750 mm
600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55
12 16 20 24 28
935 1270 1588 1906 2223
3251 4335 5418 6502 7586
12 SEC 3075 16 SEC 3075 20 SEC 3075 24 SEC 3075 28 SEC 3075
Length (mm - inches)
No. of Sections
Output (watts)
Output (Btu/h)
Order Code
Height 600 mm
600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55
12 16 20 24 28
997 1330 1662 1994 2327
3402 4537 5671 6805 7939
12 SEC 4060 16 SEC 4060 20 SEC 4060 24 SEC 4060 28 SEC 4060
Height 750 mm
600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55
12 16 20 24 28
1214 1619 2024 2429 2834
4144 5525 6906 8287 9668
12 SEC 4075 16 SEC 4075 20 SEC 4075 24 SEC 4075 28 SEC 4075
Height 2000 mm
3 COLUMN
4 COLUMN
COLUMN Sizes & Outputs
Architecture Range - Bench Radiator Length inc. seat (mm - inches)
Height inc. seat (mm - inches)
Depth inc. seat (mm - inches)
Output (watts)
Output (Btu/h)
Order Code
1850 - 73 1850 - 73 2150 - 85 2150 - 85 2350 - 93 2350 - 93
472 - 19 522 - 21 472 - 19 522 - 21 472 - 19 522 - 21
365 - 14 365 - 14 365 - 14 365 - 14 365 - 14 365 - 14
1489 1738 1816 2119 2053 2396
5080 5930 6196 7230 7005 8175
23 SEC 056150 23 SEC 066150 23 SEC 056180 23 SEC 066180 23 SEC 056200 23 SEC 066200
D
The Bench Radiator is H
sold complete, but can be sold seperately if required.
Special order only.
L
Accessories Micro Fibre Cleaning Brush
Towel Rail
Decorative Foot
Product Code: COLUMNBRUSH2
Clip-on rail to fit all
Product Code: COLDECFOOT
radiators up to 1m long (20 sections) Product Code: 12SECRAIL 16SECRAIL 20SECRAIL
Fixing Brackets
Floor Brackets
Product Code: FK1021
Product Code: SK20046
Product Code: COVERFK
Product Code: SK20061 Product Code: SK20076 Product Code: SK20091 Product Code: COVERSK
11
12
COLUMN General Specifications
General Specifications Approval and Certification All
MYSON
The installation work must be carried out in accordance with COLUMN
radiators
are
manufactured and tested to EN 442.
recognised good practice, and precautions taken to avoid contamination which could lead to corrosion. If a corrosion inhibitor or other water treatment is to be used, the
All MYSON hydronic COLUMN radiators
Manufacturer’s Instructions must be strictly followed.
carry a 10 year guarantee from date of installation against defects caused by faulty materials or
All systems must be designed with suitable pipe sizing (15mm or
manufacture.
22mm minimum depending on the length of run) and with a pump or adequate pump head. Failure to do this may lead to
2
2
2
All MYSON sealed electric COLUMN radiators
trapped air and cold spots because of insufficient pressure and
carry a 2 year guarantee from date of installation
water flow will not drive the air from the radiator. The taller and
against defects caused by faulty materials or
more tubes a radiator has, the more likely this is to happen.
manufacture. The recommendations of BS 7593, Code of Practice for treatment of water in domestic central heating systems, should be observed.
Paint Finish Every MYSON COLUMN radiator undergoes a multi-stage pre-treatment process followed by an epoxy polyester primer
Safety Precautions
coating. A stoved epoxy polyester powder coat in white (RAL
Radiators are hot when in use, and as such, present a risk of burns
9016) is applied to all front and rear surfaces allowing the
to users on prolonged contact. The temperature of a radiator is
MYSON COLUMN to be fitted without further painting. Other
dependent on the temperature of the system water, as set by the
colours are available, please refer to page 13.
system installer or user. Installers and users should ensure that those who may come into close proximity to hot radiators are aware
Manufacture
of the risk of burns. Installers and users should take all necessary
MYSON COLUMN radiators are manufactured using a unique
steps to minimise the risks of burns. If the risk is significant,
laser welding process that virtually eliminates the visible welding
consideration should be given to installing low surface temperature
points associated with the traditional methods of manufacturing
radiators, or to placing guards in front of the radiators.
this type of radiator. The clean finish significantly enhances the aesthetic qualities of the radiator.
Tube Details Precision, D-profile steel tube is used for all outside surfaces
Fixings
which ensures high outputs and soft, rounded edges for
For the correct installation of radiators it is essential that the fixing
maximum safety.
of the radiator is carried out in such a way that it is suitable for intended use AND predictable misuse. A number of elements need
Heat Output
to be taken into consideration including the fixing method used to
The heat outputs for all MYSON COLUMN radiators can be
secure the radiator to the wall, the type and condition of the wall
found on pages 10 and 11. The tabulated figures are quoted in
itself, and any additional potential forces or weights that may
accordance with EN 442 for a mean water to air temperature of
happen to be applied to the radiator, prior to finalising installation.
50oC. When the difference is not 50oC, the output should be multiplied by the appropriate factor from within the table below:
Application MYSON COLUMN radiators are for use on two pipe, pumped, Centigrade
Factor
Fahrenheit
with a maximum working temperature of 120 C. The system
40°C
0.75
72°F
should be designed in accordance with BS 5449 or BS 6880
45°C
0.87
81°F
50°C
1.00
90°F
55°C
1.13
99°F
60°C
1.27
108°F
65°C
1.41
117°F
70°C
1.55
126°F
indirect, domestic and commercial central heating installations, o
as appropriate, with particular care taken to avoid air entry or water discharge. We do not recommend the use of single feed indirect cylinders, as the possibility of aeration due to water interchange may lead to corrosion.
C O L U M N C o l o u r B o a rd
Colour Board (Hydronic Models Only)
White/Ref. 1S Ral 9016
C re a m / Ral 9001
A e g e a n G re e n / T20
P e rg a m o n / T14
L i g h t G re y / Ral 7035
Bahama Beige/ T10
Manhattan/ T11
Ye l l o w / Ral 1023
M u s t a rd / Ral 1003
Calypso/ T27
Dove/ Ral 5014
Violet/ Ral 4008
Blue/ Ral 5002
G a rd e n G re e n / Ral 6010
M o s s G re e n / Ral 6005
Ruby Red/ Ral 3003
Wine/ Ral 4004
B ro w n / Ral 8007
Chocolate/ Ral 8017
Black/ Ral 9004
IMPORTANT We can match any colour - please supply RAL reference. Due to print restrictions, exact colour match of swatches is not possible. However, every effort has been made to ensure as much accuracy as possible.
13
14
DÉCOR Range
Now Available in Electric please see page 22 for more information
V 10.
DÉCOR Range
DÉCOR Range The MYSON DÉCOR range has played a leading role in the world of interior design over the last decade. It treats radiators as decorative items as well as heating devices. With four distinctive flat tube styles to choose from you can find a model to enhance the look of any interior. We think you’ll agree that the MYSON DÉCOR range offers some stunning alternatives to mainstream radiators. The style, quality of construction and paint finish are of the highest order, so you can feel confident using MYSON DÉCOR in the most prestigious environments.
TS4.
15
16
D É C O R Te c h n i c a l I n f o r m a t i o n
DÉCOR V10 & V20 70
23 52
5
Fixing brackets
H
Fixing brackets
Connection Dimensions (V10 & V20)
33 70
Connection Dimensions
V10
V20
Wall Bracket Positioning
H
5
L
Plug
Vent
c H 110
8.2 8.2
Wall Bracket Dimensions
Water Connection
a
100 min
Distance between bottom connections = L-68
8
34
Bottom connections = 68
60 min
34
8
Bottom connections = 44
b
110
a
a = 77.5mm b = L - (2 x a)
12
BBOE (not flow specific)
12
c = H - 220 L = (Number of tubes x 75) + 5mm
= Water inlet = Water outlet
H = Height
Vent 1/8" BSP
V20
55
V10
25
DÉCOR H11 & H22 Connection Dimensions H = (Number of tubes x 75)+5
H11 Side connections = 54
Fixing brackets
H22 Side connections = 108
80 min
34
Central distance between water connections = H-68
34
5 70 5
Fixing brackets
33 110
Wall Bracket Dimensions H = (Number of tubes x 75)+5
33 52
8
8.2
12
100 min
Connection Dimensions
25
Wall Bracket Positioning Length from 600mm to 1200mm
L 150
150
Vent
4 Tubes = Water inlet = Water outlet
b
b
b
b
150
150
120
40
H
Or Plug
150 H
Plug
150
L
H
L b
110
150 110
150
L b
120
Vent
Wall Bracket Positioning Length from 1400mm to 1800mm
H 110
(Top Bottom Same End)
110
Not suitable for TBSE
6 to 10 Tubes b = L - 300
H = (Number of tubes x 75) + 5mm
Vent 1/2" BSP
4 Tubes
40
Water Connection
6 to 10 Tubes
b = L - 300 2 H = (Number of tubes x 75) + 5mm L = Length
Connections the
All TS4 (600mm high only) models must have the supplied diverter fitted inside the radiator prior to installation.
4 x 1/2 inch, including plug and vent (H11, H22 and H28) 2 x 1/2 inch BOE, including plug and vent (V10 and V20) 2 x 1/2 inch BOE, including plug and vent (TS4 2000mm high) 6 x 1/2 inch, including plug and vent (TS4 600mm high)
N.B. For H11, H22 and H28, the use of TBSE (Top Bottom Same End) connections is not suitable.
All MYSON DÉCOR following connections: H V T T
radiators
are
fitted
with
D É C O R Te c h n i c a l I n f o r m a t i o n
17
DÉCOR H28
Side connections = 64
Floor Mounting Dimensions Length from 1000mm to 1200mm
Not suitable for TBSE (Top Bottom Same End) Vent
Floor Mounting Dimensions
Adjustable Foot
119
90 to 120
34 34 Distance between water connections = H-68
5 70 5
Water Connection
33 119 H = (Number of tubes x 75)+5
Connection Dimensions
8
100 min
Connection Dimensions
Floor Mounting Dimensions Length from 1400mm to 2200mm
a=
L - 190 2
Plug Or Plug
Vent
= Water inlet = Water outlet
95
Vent 1/2" BSP
95
95
a
a
95
DÉCOR TS4 (600 & 2000)
34 Distance between bottom connections = L-68
H = Height
H = Height
a 25
Vent
Wall Bracket Dimensions*
L a a 25
Plug
a
H
2000mm high 34
8.2
Plug
12 a = 74mm
25
25
L = 308mm to 828mm
Vent 1/2" BSP
Vent
Water Connection TS4 (2000 high) = Water inlet = Water outlet
b = L - (2 x a)
= Water inlet = Water outlet
60 min
16
Bottom connections = 54
Wall Bracket Positioning* L b
70
Fixing brackets
18.5 Bottom connections = 54 Side connections = 54
TS4 (600 high)
33
Fixing brackets
34
Water Connection
Pitch
16
34
14
H
600mm high Distance between bottom connections = L-68
Connection Dimensions (2000mm High) 70
60 min
Pitch
33
Central distance between water connections = H-37
14
18.5
Connection Dimensions (600mm High)
25
Vent 1/8" BSP
*suitable for 600 & 2000mm high
NB: TS4 (600mm high only) models must have the supplied diverter fitted inside the radiator prior to installation.
Operating Pressures
Mounting Brackets
Every MYSON DÉCOR radiator is tested to a pressure of 6 bar (87 psi) and is suitable for a working pressure of up to 4.6 bar (66.7 psi).
All MYSON DÉCOR radiators are supplied with the appropriate standard brackets. V10, V20, H11, H22 and TS4 radiators are supplied with wall mounting brackets and the H28 radiator is supplied with floor mounting brackets only.
N.B. Because of the narrow waterways in longer DÉCOR TS4 radiators, care must be taken to ensure that the system pressure is sufficient to feed the whole radiator. Pressure loss data can be supplied if required.
Mounting feet for floor fixing and support for ceiling fixings can be supplied for the V10 and TS4 (2000mm high) radiator, only at the time of ordering.
18
DÉCOR Sizes & Outputs
(with fins)
DÉCOR V10
DÉCOR V20
DÉCOR H11
DÉCOR V10 Height 2000 mm
No. of Tubes
Width (mm - inches)
Output (watts)
Output (Btu/h)
Order Code
6 8 10
455 - 18 605 - 24 755 - 30
991 1322 1652
3381 4511 5637
6V10200 8V10200 10V10200
No. of Tubes
Width (mm - inches)
Output (watts)
Output (Btu/h)
Order Code
8 11 13 16 18
605 - 24 830 - 33 980 - 39 1205 - 48 1355 - 54
680 935 1105 1360 1530
2320 3190 3770 4640 5220
8V20060 11V20060 13V20060 16V20060 18V20060
DÉCOR V20
Height 600 mm
DÉCOR H11 Length (mm - inches)
Output (watts)
Output (Btu/h)
Order Code
4 Tube 305 mm
600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72
347 462 578 694 809 1040
1184 1576 1972 3262 2760 3548
4H11060 4H11080 4H11100 4H11120 4H11140 4H11180
6 Tube 455 mm
600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72
478 638 797 956 1116 1435
1631 2177 2719 3262 3808 4896
6H11060 6H11080 6H11100 6H11120 6H11140 6H11180
8 Tube 605 mm
600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72
602 802 1003 1204 1404 1805
2054 2736 3422 4108 4790 6159
8H11060 8H11080 8H11100 8H11120 8H11140 8H11180
10 Tube 755 mm
600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72
721 962 1202 1442 1683 2164
2460 3282 4101 4920 5742 7384
10H11060 10H11080 10H11100 10H11120 10H11140 10H11180
DÉCOR Sizes & Outputs
(with fins)
DÉCOR H22
DÉCOR H28
DÉCOR TS4
DÉCOR H22 Length (mm - inches)
Output (watts)
Output (Btu/h)
Order Code
6 Tube 455 mm
600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72
833 1110 1388 1666 1943 2498
2842 3787 4736 5684 6630 8523
6H22060 6H22080 6H22100 6H22120 6H22140 6H22180
8 Tube 605 mm
600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72
1027 1369 1711 2053 2395 3080
3504 4671 5838 7005 8172 10509
8H22060 8H22080 8H22100 8H22120 8H22140 8H22180
10 Tube 755 mm
600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72
1206 1608 2010 2412 2814 3618
4115 5486 6858 8230 9601 12345
10H22060 10H22080 10H22100 10H22120 10H22140 10H22180
Length (mm - inches)
Output (watts)
Output (Btu/h)
Order Code
2 Tube 155 mm
1000 - 40 1400 - 55 1800 - 72 2200 - 88
682 955 1228 1500
2327 3258 4190 5118
2H28100 2H28140 2H28180 2H28220
4 Tube 305 mm
1000 - 40 1400 - 55 1800 - 72 2200 - 88
1195 1673 2151 2629
4077 5708 7339 8970
4H28100 4H28140 4H28180 4H28220
DÉCOR H28
DÉCOR TS4 No. of Tubes
Width (mm - inches)
Output (watts)
Output (Btu/h)
Order Code
Height 600 mm
15 21 25 31 35
588 - 23 828 - 33 1028 - 41 1228 - 49 1428 - 56
506 708 843 1045 1180
1726 2416 2876 3566 4026
15TS4060 21TS4060 25TS4060 31TS4060 35TS4060
Height 2000 mm
8 11 13 16 18 21
308 - 12 428 - 17 508 - 20 628 - 25 708 - 28 828 - 33
936 1287 1521 1872 2106 2457
3194 4391 5190 6387 7186 8383
8TS4200 11TS4200 13TS4200 16TS4200 18TS4200 21TS4200
19
20
DÉCOR General Specifications
General Specifications Approval and Certification All
MYSON
All systems must be designed with suitable pipe sizing (15mm or DÉCOR
radiators
are
manufactured and tested to EN 442.
22mm minimum depending on the length of run) and with a pump or adequate pump head. Failure to do this may lead to trapped air and cold spots because of insufficient pressure and
All MYSON hydronic DÉCOR radiators carry
water flow will not drive the air from the radiator. The taller and
a 10 year guarantee from date of installation
more tubes a radiator has, the more likely this is to happen.
against defects caused by faulty materials or manufacture.
The recommendations of BS 7593, Code of Practice for treatment of water in domestic central heating systems, should be observed.
2
2
2
All MYSON sealed electric DÉCOR radiators carry a 2 year guarantee from date of installation
Safety Precautions
against defects caused by faulty materials or
Radiators are hot when in use, and as such, present a risk of burns
manufacture.
to users on prolonged contact. The temperature of a radiator is
Paint Finish
dependent on the temperature of the system water, as set by the system installer or user. Installers and users should ensure that
Every MYSON DÉCOR radiator undergoes a multi-stage
those who may come into close proximity to hot radiators are aware
pre-treatment process followed by an epoxy polyester primer
of the risk of burns. Installers and users should take all necessary
coating. A stoved epoxy polyester powder coat in white (RAL
steps to minimise the risks of burns. If the risk is significant,
9016) is applied to all front and rear surfaces allowing the
consideration should be given to installing low surface temperature
MYSON DÉCOR to be fitted without further painting. Other
radiators, or to placing guards in front of the radiators.
colours are available, please refer to page 21.
Tube Dimensions Fixings For the correct installation of radiators it is essential that the fixing of the radiator is carried out in such a way that it is suitable for intended use AND predictable misuse. A number of elements need to be taken into consideration including the fixing method used to secure the radiator to the wall, the type and condition of the wall itself, and any additional potential forces or weights that may happen to be applied to the radiator, prior to finalising installation.
Headers Triangular 51mm x 42mm x 42mm header: thickness 1.5mm Heating tubes Flat 70mm x 11mm: thickness 1.25mm
Heat Output The heat outputs for all MYSON DÉCOR radiators can be
Application
found on pages 18 and 19. The tabulated figures are quoted in
MYSON DÉCOR radiators are for use on two pipe, pumped,
accordance with EN 442 for a mean water to air temperature of
indirect, domestic and commercial central heating installations,
50oC. When the difference is not 50oC, the output should be
with a maximum working temperature of 100oC. The system
multiplied by the appropriate factor from within the table below:
should be designed in accordance with BS 5449 or BS 6880 as appropriate, with particular care taken to avoid air entry or water discharge. We do not recommend the use of single feed indirect cylinders, as the possibility of aeration due to water interchange may lead to corrosion.
Centigrade
Factor
Fahrenheit
40°C
0.75
72°F
45°C
0.87
81°F
50°C
1.00
90°F
55°C
1.13
99°F
The installation work must be carried out in accordance with
60°C
1.27
108°F
recognised good practice, and precautions taken to avoid
65°C
1.41
117°F
contamination which could lead to corrosion. If a corrosion
70°C
1.55
126°F
inhibitor or other water treatment is to be used, the Manufacturer’s Instructions must be strictly followed.
D É C O R C o l o u r B o a rd
Colour Board (Hydronic Models Only)
White/Ref. 1S Ral 9016
P e rg a m o n / Ref. 64
Jasmin/ Ref. 63
Natura/ Ref. 73
Bahama Beige/ Ref. 61
Metallic Silver/ Ref. 27
Edelweiss/ Ref. 59
Camelia/ Ref. 53
Manhattan/ Ref. 31
Pastel Rose/ Ref. 54
Pastel Blue/ Ref. 56
Cool Mint/ Ref. 70
Keywest/ Ref. 80
IMPORTANT We can match any colour - please supply RAL reference. Due to print restrictions, exact colour match of swatches is not possible. However, every effort has been made to ensure as much accuracy as possible.
21
22
Electric COLUMN & DÉCOR
Available Now
Electric COLUMN. The proportions, scale and detailing of the round tube Electric COLUMN combine to give a symmetry and elegance that feels just right. Available in horizontal and vertical styles with a paint finish that is second to none, there is a size and column configuration to suit every need.
Electric COLUMN Horizontal.
Electric DÉCOR. Electric COLUMN Vertical.
The Electric DÉCOR offers a stunning alternative to mainstream radiators with its distinctive and contemporary flat tube design. Available in horizontal and vertical styles with high quality white gloss paint finish, you can find a model to enhance the look of any interior.
Electric DÉCOR Horizontal.
Electric DÉCOR Vertical.
E l e c t r i c C O L U M N & D É C O R Te c h n i c a l I n f o r m a t i o n
Electric COLUMN Technical Information Electric COLUMN Horizontal Order Code
Width (mm)
Height (mm)
Heat Outputs (watts)
E8-3060 E10-3060 E12-3060 E14-3060
450 550 650 750
600 600 600 600
500 750 1000 1250
133-143
94-104
Electric COLUMN Vertical Order Code
Width (mm)
Height (mm)
Heat Outputs (watts)
E8-2180 E12-2180
400 600
1845 1845
1000 1500
Electric COLUMN Horizontal
Electric COLUMN Vertical
Projection (mm)
Projection (mm)
Electric DÉCOR Technical Information Electric DÉCOR Horizontal Order Code
Width (mm)
Height (mm)
Heat Outputs (watts)
E6V20060 E8V20060 E11V20060 E13V20060
485 635 860 1010
600 600 600 600
500 750 1000 1250
106
75
Electric DÉCOR Vertical Order Code
Width (mm)
Height (mm)
Heat Outputs (watts)
E6V10180 E9V10180
455 680
1835 1835
1000 1500
Electric DÉCOR Horizontal
Electric DÉCOR Vertical
Projection (mm)
Projection (mm)
Wireless Thermostats Wall mounted wireless thermostats are available that will control one or more Electric COLUMN or Electric DÉCOR radiators in any one room, using only a single remote control!
23
MYSON Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568, sales@myson.co.uk, www.myson.co.uk
heatingthroughinnovation.
01.11.2011
MYSON