2012_DVM

Page 1

2012 SAMSUNG SYSTEM AIR CONDITIONERS USP BOOK

Learn more about Samsung air conditioner at: www.dvmsystem.com

A Fresh Breeze in the World, Samsung Air Conditioner Experience the real satisfaction and comfort of a pleasant environment filled with fresh air by Samsung System Air Conditioner.

Ver.1.0 2011.12 _ for SAUDI


One Step Ahead for Better Air Solution Samsung air conditioner is a perfect solution for your desired environment. The refreshing air delivers the utmost comfort to keep you invigorated. Experience the wonders of smart air conditioners that take your life to another level of easier, simpler living. Stay comfortable all day long with clean and healthy breeze brought to you by Samsung air conditioner.


“Put simply, our differentiation is centered on producing innovative technology that brings genuine change to people’s lives. We do this by bringing a relentless focus on consumer experience and product innovation in everything we do.” - Sue Shim CMO (Chief Marketing Officer), SAMSUNG

Brand Value

Introduction

Samsung is moving ahead and with our customers

2009 Best Global Brand

Rank. 19 17,518 $m

2010 Best Global Brand

Rank. 19 19,491 $m 2008 Best Global Brand

Rank. 21 17,689 $m

Global Business Network 11 Global Operation Centers

10 Global Headquarters

4 HA R&D Centers

7 Design Centers

CIS

London Poland

Chicago

Stuttgart Europe

US

Los Angeles

Korea

Milano China

ME N Africa India

Malaysia

SE Asia

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Africa

Vietnam

05

04

SW Asia

Brasil Latin America

Osaka Shanghai

Thailand

Mexico

Japan Tokyo


Preserves the nature you live in. Thinking of you and the environment, Samsung plans for the future. Realizing your hopes for a greener, healthier life for you and the generations that follow, Samsung’s environment-friendly technologies work to make the world a more beautiful place.

Air & Water Conservation As a leading innovator of environment-friendly products and technologies, Samsung products already drastically reduce the strains on nature’s valuable resources. Samsung uses cyclopentane insulation in its refrigerators not to promote greenhouse effect and thus to prevent global warming. Samsung’s water-efficient washing machines also effectively operate with less detergent and water to conserve nature.

Eco-friendly Policy

Introduction

‘Eco-friendly’ Samsung

Samsung Eco-Friendly Air Conditioner Making continuous efforts to stay eco-friendly, Samsung air conditioners use R-410A, an environment-friendly refrigerant to help rid the air of pollutants and restrain the use of materials with high global warming potential(GWP). These energy-efficient air conditioners not only save you money, but help conserve the environment.

Use Less, Save More Samsung washers with its ceramic heaters use less power which saves you energy, money and time. This energy-efficient technology protects you and nature for your greener life style.

Global Recycling

07

06

Samsung Electronics has taken a leading role in saving the environment and compiles with the WEEE (Waste Electrical and Electronic Equipment) Directive by joining or establishing the recycling schemes for each country.

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner


Awards

Introduction DU BR CTI EC AND ON V O A AW -FR LU E I A EN OU R DL R DS YP PO OL RT ICY FO LIO

4p

INT

RO

12p ITS

N RU

O

DO

T OU

RT

ESE

D DVM

2012 SAMSUNG AIR CONDITIONER

Contents

INDOOR UNITS

22p

CASSETTE TYPE DUCT TY PE WALL -MOU NTED CEIL TYPE ING TYPE

CO

N

70p

09 2012 SAMSUNG System Air Conditioner

Good Design Award is a comprehensive program for the evaluation and encouragement of design organized by Japan Institute of Design Promotion (JDP). This has been a program advancing lifestyle and industrial activity by selecting outstanding design. Samsung air conditioner , Y series, has advanced the finals for the year 2011.

NS

Organized by Fiera Milano International, 37th Mostra Convegno Expocomfort / Expobagno 2010 aimed to reward the best product that shows a high level of environmental quality, providing a complete overview of the sector along the lines of “Comfort & Living Technology”. And Samsung air conditioner won the prize conferring a valid and professional recognition for the best product in the ceremony .

IO

As one of the world’s oldest & prestigious design competitions, the iF product design award has stood for qualitatively outstanding design awards for over 50 years. And Samsung air conditioner with its design innovations has won the iF product design award for the year 2009. Samsung air conditioner continues to receive worldwide recognition and awards, proving high quality of function and beauty.

46p

N

Samsung attended Europe’s largest air-conditioner exhibition “Climatization” in Madrid, Spain. Samsung air conditioner’s beautiful design with innovative features was awarded the “Galeria de Innovacion”. The idea behind this award is to encourage innovation in the practical application of know-how and technologies in industrial development. Once again, Samsung proves its unsurpassed standards in quality.

TIO

Good Design Award 2011

CA

Comfort & Design 2010

AT

IC PL AP

2012 SAMSUNG System Air Conditioner

iF Product Design Award 2009

IFI EC

SP

08

Galeria de Innovacion 2009

TR INT OL SY EGR SY S A ST BU TE TE EM DM ILD M C AN IN ON A G GE TR M ME OL AN NT L AG ER EM EN T


Our Portfolio

Introduction

Global Operation of Samsung System Air Conditioner Samsung system air conditioners are chosen by various groups from different countries all around the world for their proven performance.

Location_Germany

Location_Greece

Location_Slovenia

Location_South Africa

Location_Korea

Project_Soccer Stadium

Project_Restaurant

Project_Utility Company

Project_Hotel

Project_Residential Building

Location_Hungary

Location_Croatia

Location_Vietnam

Location_Korea

Project_Shopping Mall

Project_Office & Residential Building

Project_Hotel

Project_Soccer Stadium

Location_France

Location_Turkey

Location_Germany

Location_China

Location_Korea

Project_Hotel

Project_University

Project_Business Park

Project_Business Park

Project_Tourist Attraction

Location_Turkey

Location_China

Location_Vietnam

Location_India

Project_Apartment Building

Project_Hotel

Project_International Airport

Project_Hotel

Project_Training Center

Location_Turkey

Location_Turkey

Location_Turkey

Location_Saudi Arabia

Location_Qatar

Location_U.A.E

Location_Austria

Project_Princess Resort

Project_Office building

Project_Office Building

Project_Medical Clinic

Project_Office Building

Project_Residential Building

Project_Cityhall Traiskirchen

11

10

Location_Czech Republic

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner


With its advanced components and technologies, DVM Desert provides the most powerful and reliable cooling performance, capable of efficiently withstanding high ambient conditions. This air conditioning system has achieved world-class energy efficiency and cooling capacity, making it a perfect fit for large buildings.

High Efficiency

Powerful and Reliable

Continuous and Reliable Operation in 54 C High Ambient Condition O

DVM Desert is designed to withstand extremely hot weather and harsh operating conditions. It can continuously operate in 54ÂşC condition thanks to its advanced components and technologies.

Low Side Design of Compressor The low side design of the compressor is perfectly suited for high ambient conditions: the internal pressure and temperature of the compressor is kept low and stable, thus maximizing performance and efficiency.

Discharge

Suction Suction

Features Discharge

Reliable Operation in 54OC High Ambient Condition

Lower Internal Pressures & Lower Internal Temperatures

High Efficiency Large Capacity

Low Pressure High Pressure

Advanced and Reliable Protection Easy Installation & Maintenance Eco-friendly

Low Side Design

High Side Design

Pleasant Operation

Digital Scroll Compressor With its simple mechanical structure, the digital scroll compressor secures outstanding durability and flexibility and is resistant to internal overheating. This efficient and reliable compressor improves cooling performance and energy efficiency.

PHE (Plate Heat Exchanger)

Heat Exchanger Performance

150% 107%

115%

121%

13

DVM Desert has adopted Plate Heat Exchanger type intercooler to improve cooling efficiency. The energy efficiency with PHE has been improved by 35% compared to the conventional products with Shell & Tube type intercooler and 50% compared to the competitor’s products with Double Pipe type intercooler.

EER

100% 100%

Shell & Tube PHE Intercooler

Company A

Conventional

2012 SAMSUNG System Air Conditioner

Double Pipe


Large Capacity

High Efficiency

Bigger and Better Heat Exchanger With its size which now has grown about 10% larger than the conventional product, the outdoor unit heat exchanger has also been greatly improved in its efficiency. The double fan system that increases air flow rate by 30% and the DVM chassis using a newly optimized fin design enhance the performance of the heat exchanger.

Conventional

The World’s Largest Capacity Economical Installation Cost! The single unit, which provides the world’s largest module capacity, is ideal for larger buildings. Installing larger capacity modules will also save on installation costs since less equipment is required when you use units that offer greater capacities.

12HP

Energy Efficiency EER

8HP

8HP

DVM Desert Company A

3.3

DVM Desert has achieved the highest level of energy efficiency (EER) with an average of 2.95 in high ambient conditions, demonstrating more efficient and reliable performance against extreme outside temperatures.

12HP

Extra Piping

16HP World-class Energy Efficiency in High Ambient Condition

12HP

COST

Single

48HP

12HP

Company B

3.2

SAMSUNG

Company A

䚚Compariosn is based on the installation of 48HP models.

3.1 3.0

World’s Largest Module Capacity

2.9 2.8 2.7 8

10

12

14

16

(HP)

64HP

Single piping installation is possible from mid-sized buildings to high-rise buildings.

o

Comparison of 46 C Cooling Energy Efficiency

Optimized Air Discharge Profile The air discharge profile within the Fan and the Fan Guard is optimized for faster heat exchange, which increases efficiency and provides faster cooling and heating.

World’s Largest Single Capacity

16HP

Economical installation with smaller footprint area and lighter weight.

Outdoor Unit BLDC Fan Motor 100%

DVM Desert uses a BLDC motor, which is 35% smaller and 39% more efficient than conventional AC motors.

89% 65%

35%

Improved by

50%

Efficiency

2012 SAMSUNG System Air Conditioner

BLDC Motor

AC Motor

BLDC Motor

AC Motor

2012 SAMSUNG System Air Conditioner

Size

15

14

39%

Smaller


Advanced and Reliable Protection

Self-diagnosis Mode

Oil Balancing Control DVM Desert uses oil balancing technology that ensures that oil distribution is stable and equal, even when multiple outdoor units are installed at various levels or distance. This allows flexible installation options for outdoor units.

Internal Oil Balancing Control

DVM Desert monitors the operation status and displays an error code in response to any sign of abnormal activity, thus enabling you to easily solve the problem.

External Oil Balancing Control The flow of the oil between the outdoor units within the module will be balanced, even when the outdoor units are installed away from each other or at different heights.

A stable and optimized amount of oil will be evenly balanced between the compressors within the outdoor units regardless of the compressors’ On/Off status.

Pre-protection System DVM Desert uses special internal fuse devices to protect the compressors from possible damage caused by overcurrent.

Company A Oil balancing control allows outdoor units to be freely installed within a 5m height difference.

Sequential Operation of Compressor When the outdoor unit is not operating at full capacity, the compressor will start up the operation in sequence to prevent one particular compressor from overworking. This sequential operation for compressors will prolong the life of the compressor and ensure the reliability of performance.

Multiple outdoor installation is impossible since the level difference between outdoor units will cause oil circulation problems.

1st Cycle

2nd Cycle

3rd Cycle

Start

Start

Start

Easy and Safe Wiring Work Non-polar communication between indoor and outdoor units makes wiring work much easier. This is also safer since the outdoor unit will protect itself in case the communication cable is connected to a power terminal by mistake. Protected

Non-polarity Variable

Fixed

Fixed

Variable

Fixed

Fixed

Variable

Fixed

Fixed

Power Breaker

Outdoor unit

Compressor operation priority

Corrosion & Frost Resistant

Normal operation even when communication cables are not connected correctly

Indoor unit A

Indoor unit B

Air conditioner is protected even when power / communication cables are not connected correctly

Hydrophilic layer acrylic resin+surfactant Anti-corrosive layer epoxy acrylic Raw aluminum material

t $PSSPTJPO SFTJTUBOU XJUI FQPYZ BDSZMJD DPBUJOH

1 Hydrophilic 2 Heat Spread Corrosion resistant finishing on heat exchanger fin

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

t *NQMFNFOUFE DPSSPTJPO SFTJTUBOU UISPVHI acrylic+surfactant.

3 Corrosion Resistance

Indoor unit B

17

16

The highly hydrophilic coating facilitates efficient heat exchange and delays the onset of frost formation to provide consistent heating performance. An anti-corrosive coating also helps units to resist corrosion from the elements.

Indoor unit A


Easy Installation & Maintenance

Longest Piping Length & Highest Elevation

Black box (Automatic Data Backup) If a malfunction occurs with DVM Desert outdoor unit, it will automatically diagnose the problem and save the last 30 minutes of operation data. An optional accessory can be used to store operational data for over one year, which can be helpful in getting you quick and accurate repair service when you need it.

The longest piping length

220m 110m

S-NET Pro

Level differences between Indoor and Outdoor Units 䚚䎃If you wish to install piping with a level difference between indoor and outdoor units over 50m, then please contact your local Samsung Dealer.

Refrigerant Pump-down and Pump-out

15m

DVM Desert provides the refrigerant pump-down/out functions to facilitate easy and convenient replacement of the product, as well as additional installations and maintenance. In case of outdoor unit maintenance, it is possible for the refrigerant to recover into indoor units or pipes. It is also possible to recover refrigerant into outdoor units when moving indoor units or performing maintenance of pipes between indoor units and outdoor units.

Level differences between Indoor Units

Flexible Installation in High-rise Buildings

Flexible Installation over Wide Area

Flexible Selection of Indoor Units

Installation is available with a maximum height level of 110m, which is equivalent to 20 stories (each story is considered to be a 5m high).

DVM Desert allows extended piping length up to 220m, and units will still give a great performance over wide areas.

You can choose indoor units which are suitable for each space, offering various options in capacity and composition. You can also enjoy the indoor units more economically since each indoor unit can be individually controlled.

1 2

3

Side : Communication cable outlet

The knock-out holes for piping, power, and communication cables are located in a variety of directions, allowing for more convenient installation of DVM Desert since the piping and cable direction can be freely selected from the front, left, and right side.

Easier Access for Status Check and Option Settings

Optimized Refrigerant Distribution Control Auto pressure correction

P (Pipe pressure loss)

Checking the outdoor unit status and setting option are easier and simpler since you don’t need to remove the entire front cover, thanks to the small openings on the front side of the outdoor unit.

19

18

When long piping is installed between the outdoor units and indoor units, the individual indoor units will use auto performance correction control technology and automatic refrigerant amount adjustment technology to secure balanced performance between the units.

Versatile Piping Connection with Various Knock-out Holes

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner


To properly deal with unexpected various installation conditions, DVM Desert is designed to manage high external static pressures up to 8mmAq.

Decreased CO2 Emission DVM Desert is a highly efficient product that adopts advanced eco-friendly technology to reduce carbon dioxide (CO 2) emissions. t $02 emission level: Data based on 0.42kg/kWh t 5JNF QFSJPE NPOUIT /PW _ .BS IPVST

t %BUB CBTFE PO )1 NPEFM IFBUJOH

8.8%

20,714

18,900

SAMSUNG

Company A

Eco-friendly

Easy Installation & Maintenance

8mmAq

High External Static Pressure

CO2 Emission

Automatic Pipe Length Recognition

R410A Refrigerant

The system provides evenly powerful cool and warm air, regardless of the distance.

DVM Desert adopts a new compressor that is optimized with eco-friendly R410A refrigerant, which has a “0� ODP value, to minimize environmental pollution. This also improves refrigerant operation efficiency and performance.

40m

Ozone Depletion Potential (ODP)

0.05

Ozone Depletion Potential

0

10m

STEP5 STEP4 STEP3

STEP2 STEP1

Comm.& Sensor Check Power check

Operation Staus Check Operation check - Compressor operation - Fan operation

Service valve locking check

(Opposite phase, Open phase)

Communication check (Between Indoor/Outdoor units)

Main/Fan board Sensor open/short Save S/N and Option value

Data Backup Save diagnosed data Displays error

Valve Check

Pipe length Refrigerant amount judgment (Optional function)

4 W/W operation

(in Cooling operation)

(in Heating operation)

EVI EEV Indoor EEV opening problem Incorrect HR piping connection

EEV malfunction (in Heating operation)

Self sensor diagnose

RoHS(Restriction of Hazardous Substances Directive) RoHS sets eco-friendly regulations that ban the use of toxic substances, such as mercury, lead, and cadmium, that are obstacles in electronic recycling.

(Optional function)

(Possible section)

S/V lock (Oil balancing)

Self fan diagnose Compressor operation current Cycle status (DSH)

WEEE

Automatic Report Function Complete

Start

SAMSUNG invests significant efforts to help save the environment and comply with the WEEE Directive by joining or establishing recycling schemes for each country. Perfect

PC About 40 min.

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Automatic report

21

20

After installation, the DVM Desert self-checks the product status and automatically reports the results to a designated computer. You can easily examine and check all the results by selecting the check button while our competitor's products require the results to be separately checked.

Europe Eco-friendly RoHS Technology Certification Samsung minimizes the use of toxic substances such as mercury, lead, and cadmium, attaining RoHS certification with its excellent eco-friendly technology.

PWM valve Liquid valve Oil gas valve Hot gas valve 4-Way valve

Major Parts Check

R22

R410A

Multi-step Diagnosis Function


Smart and Stylish

With its newly improved design, 4Way Cassette S brings the sophisticated and clean atmosphere and adds a sense of class to your space. Not only is this unit attractively designed, but it also uses the advanced technologies to optimize your comfort in any environment. Feel the power and enjoy the beauty with 4Way Cassette S.

General features

Smart and Stylish 4Way Cassette S

Cassette Type

Stylish and Aesthetic Panel 4Way Cassette S supports two different pattern designs of panels. You can select between the Waffle and Classic pattern, depending on your interior’s look or personal preference.

Waffle Patterm

Classic Patterm

Simple Display The simple display design with its rounded corners adds a neat and tidy feeling to your interior.

Power

Defrost

Time

Clean

Neat and Clean Design 4Way Cassette S uses a new neat and clean design. The completely hermetic blade structure keeps the indoor unit clean since it prevents dust or other foreign substances from entering it. The internal parts of the indoor unit are also out of sight once the blade is shut, thus improving the unit’s appearance.

Neat and Clean Design

Light yet Robust Design Samsung 4Way Cassette S indoor unit is now lighter in weight at 17kg. It is the lightest indoor unit in the industry, about 35% lighter than our competitor’s products.

23

SAMSUNG

Company A

2012 SAMSUNG System Air Conditioner

Based on 10kW


Smart and Stylish 4Way Cassette S

MDS; Motion Detection Sensor (Optional)

S-Plasma ion (Optional): Healthy Air Provider

The world’s first MDS for 4Way Cassette S creates the ideal environment, saving energy by providing the optimized amount of airflow when needed.

S-Plasma ion device eliminates airborne contaminants and creates even healthier air for your environments. This optional device can be easily installed by simply inserting S-Plasma ion kit into the indoor unit.

1

S-Plasma ion Kit

Energy Saving On / Off Function Power ON

Power OFF

MDS detects when the user is absent, automatically stopping the air conditioning operation. It also automatically sets operation patterns to maximize energy efficiency.

Operation & Algorithm Active Hydrogen(H)

2

S-Plasma ion device generates active hydrogen and oxygen ions which eliminate biological contaminants and active oxygen (OH- radical) in the air by turning them into harmless H2O.

Pleasant and Comfortable Air MDS enables the indoor unit to avoid directly providing airflow to people and reduces the difference of thermal sensation in the body by detecting the temperature around floor.

Oxygen(O2-)

Virus & Active Hydrogen

Turns into Harmless H2O

No Overflowing Drain Water

Benefits of S-Plasma ion

The check valve on the drain pump prevents drained water from flowing backward into the drain pan. This minimizes the the drain pan’s water level so that you will never have to worry about water stagnation or overflowing drain water that could drip into your interior.

t &MJNJOBUJPO PG BJSCPSOF WJSVT CBDUFSJB 4VCUZQF ) /

t $PNQMFUF FSBEJDUJPO PG CBDUFSJB t 3FMJFG PG BMMFSHJFT CZ FSBEJDBUJOH BJSCPSOF BMMFSHFOT t /FVUSBMJ[BUJPO PG 0)-radical (as known as active oxygen) Eliminates Subtype H1N1 Virus

Complete Bacteria Eradication

Neutralize Active Oxygen

Check valve: Prevents drain water from reversing

Freedom from Allergens

Minimizes Remaining Drain Water

H

ONE-WAY FLOW

CLEAN CEILING

NO OVERFLOW

NO STAGNATION

Individual Blade Control

Easy Leveling

By using new remote controller, the opening angles of the 4 blades can be individually set at the same or different angles within a 32O~65O range for more efficient cooling.

Each corner portion of the panel is detachable: this makes it easier for you to adjust the height, and makes installation and leveling much easier and quicker.

W

25

24

32䎲~65䎲

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner


Turbo Fan

The optimum fan speed for high ceiling can be achieved just by using the remote controller without adjusting the DIP switch on the indoor unit’s PCB. The fan speed adjustment function provides evenly cool and warm air throughout space with high ceiling of up to 3.5m.

Not Applied

2.7m

1

Silent Operation Imagine a room of cool calmness. The aerodynamically designed Turbo Fan minimizes noise from the turbulence of blade movement, meaning that our units make less noise than conventional models.

Applied via Remote Controller

3.5m

2 Fan Speed Adjustment

MR-DH00

䮝5.2~10.0kW Units

Uniform Distribution Turbo Fan with wide blades provides extreme cooling and heating power from 4 separate outlets so the entire room cools down or warms up faster. This unit can extend comfort to every nook and cranny.

High Ceiling Mode The high ceiling mode allows indoor units to provide even more powerful airflow throughout your space. This mode enlarges the coverage area of the airflow up to a height of 4.6m.

m2/min.

Smart and Stylish 4Way Cassette S

Fan Speed Adjustment for High Ceiling

13.0

3.6m

4.6m

10.0

4Way

Conventional 4Way

4Way

Conventional 4Way

4Way

Conventional 4Way

4Way

SAMSUNG

Conventional 4Way

CAE Analysis Results

Company A Outlet 1

Easy Blade Cleaning

Surround Air Flow

4Way Cassette S indoor units have detachable air flow blades so that you don’t need to remove the entire panel to clean the blades.

The 4-way outlet can cool every portion of your interior. The new and practical design of the blades minimizes blind spots at the corners of the panel, and can almost cover a full 360O around the indoor unit.

Outlet 2

Outlet 3

Outlet 4

Covers 360O

Quick Cooling and Heating Samsung 4Way Cassette S indoor unit achieves the desired set temperature much faster than our competitor’s products.

27

26 30 Minutes SAMSUNG

25% Faster

Heating After Approximately

40 Minutes Company A

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Heating After Approximately


Drain pan is included within the panel.

NOTE Min. 170mm Ceiling

Make sure that there is enough installation space. Allow at least 170mm for the installation.

Lighter Indoor Unit 17kg

Weight

Samsung is the first to apply ABS cabinets into its indoor units to provide the lightest units on the market. The slim and lightweight design makes installation and maintenance a breeze.

38%

10.5kg

Down

Company A

SAMSUNG

4kW R410A model

Quiet Operation 43dB

Samsung new blade design drastically reduces noise levels so that you can relax in peace and quiet.

Noise level

General features

Samsung Slim 1Way Cassette indoor unit is only 135mm thick and can be installed on ceilings, taking up little space.

155mm

Slim and rounded design of Slim 1Way Cassette adds a sense of unity with ceilings, resulting in a clean and neat appearance. Slim 1Way Cassette is an optimized air solution that suits your both practical and aesthetic needs with its simple design and efficient cooling system.

Slim and Compact Design 135mm

Slim and Quiet

Slim and Quiet Slim 1Way Cassette

Cassette Type

35dB 30dB 25dB

30% Down

29% Down

SAMSUNG

Company A

SAMSUNG

Company A

Low Fan Speed

High Fan Speed

No Overflowing Drain Water Check valve: Prevents drain water from reversing

29

The check valve on the drain pump prevents drained water from flowing backward into the drain pan. This minimizes the the drain pan’s water level so that you will never have to worry about water stagnation or overflowing drain water that could drip into your interior space.

H

ONE-WAY FLOW

CLEAN CEILING

NO OVERFLOW

NO STAGNATION

W

2012 SAMSUNG System Air Conditioner

Minimizes Remaining Drain Water


2Way Cassette is a perfect fit for long and narrow places with limited installation space, thanks to its compact and slim size. The unit operates with air coming out from two sides, providing powerful and fast cooling and heating performance to create a pleasant environment for you.

General features

Ideal for Long and Narrow Places With its slim and compact size, 2Way Cassette indoor unit is ideal air solution for long and narrow places such as corridor and classroom. This unit saves space up to 30% compared to conventional 4Way cassette as well as blends into the interior design.

Small Size, Big Performance 2Way Cassette indoor unit is now 45% smaller than our competitor’s models, making it even easier to incorporate into building design.

45%

Decreased

230mm

305mm 600mm

575mm

1,180mm

Company A

890mm

SAMSUNG

Twin Cross Flow Fan 2Way Cassette type unit is a perfect fit for long and narrow rectangular spaces. The Twin Cross Flow Fan inside 2Way Cassette will spread cool or warm air even further and wider with less noise.

Cross Flow Fans

Standard formula for Easy Installation The dimensions of 2Way Cassette air conditioner allow for easy installation into standard ceiling grids (600Wx600D) in such a way that everything just falls into place.

31

1030mm

600mm

2012 SAMSUNG System Air Conditioner

600mm

650mm

Compact but Powerful

Compact but Powerful 2Way Cassette

Cassette Type


Features

Duct Type

Auto Surround Swing The 2-way outlet blades swing right and left to evenly distribute cool and warm air to every nook and cranny of your space, keeping your environment pleasant and comfortable.

Icon Description

Anti-virus Filter

20o

Anti-virus filter not only traps dust particles, but suppresses the proliferation of mold and bacteria.

60o

SAMSUNG

Conventional

Self-diagnosis Mode In case of unit malfunction, the indoor unit operates the selfdiagnosis mode to display an error code with LED light, thus enabling you to easily resolve the problem.

Easy Filter Cleaning After 1,000 hours of operation, the filter clean indicator will notify you that the filter should be cleaned. The filter can be easily removed from the bottom, left, or right of the unit. (1,000 hours is the default set time, which can be adjusted to 2,000 hours on the internal PCB.)

Display

Filter

Dry

Time

Power

Optimum Temperature Control Smart Pressure Control

18OC

B

A

B A

19OC

O

20 C

Smart Pressure Control System adjusts fan speed according to E.S.P (External Static Pressure) so the air conditioner always provides you with consistent cooling and heating power, regardless of the surrounding environment.

H

Air Volume

The Optimum Temperature Control function detects and minimizes the temperature difference between the top and bottom of the space to maintain an optimum temperature. You can set the temperature detection option with indoor unit or optional remote controller .83 8&

M L H M L

O * The average temperature is set at 19 C

t " 5FNQFSBUVSF TFU CZ SFNPUF DPOUSPMMFS t # 5FNQFSBUVSF TFU CZ JOEPPS VOJU t "WFSBHF PG " # 5IF BWFSBHF UFNQFSBUVSF Minimum

Maximum

Static pressure (mmAq)

High Lift-up Drain Pump (Optional)

33

32

The lift-up drain pump lifts condensed water up to 750mm, compared to our competitor's limit of 700mm, allowing for flexible and convenient installation.

Ceiling

2012 SAMSUNG System Air Conditioner

Max : 750mm

2012 SAMSUNG System Air Conditioner

䋪䎡ä?‹ä?ˆäŽƒä??ä?Œä?‰ä?—äŽ?ä?˜ä?“䎃ä?•ä?„ä?‘ä?Šä?ˆäŽƒä?’ä?‰äŽƒä?‡ä?•ä?„ä?Œä?‘䎃ä?“ä?˜ä??ä?“䎃ä?‰ä?’ä?•äŽƒäŽŤäŽśäŽłäŽƒäŽ§ä?˜ä?†ä?—䎃䎋䎕䎕䎒䎕䎛ä?ŽäŽşäŽŒäŽƒä?„ä?‘ä?‡äŽƒäŽŠä?•ä?ˆä?–ä?‹äŽƒäŽ¤ä?Œä?•äŽƒäŽŹä?‘ä?—ä?„ä?Žä?ˆäŽƒäŽ§ä?˜ä?†ä?—䎃ä?Œä?–䎃ä??ä?Œä??ä?Œä?—ä?ˆä?‡äŽƒä?—ä?’䎃䎗䎚䎓ä??ä??䎑


Powerful and Flexible

To properly deal with unexpected various installation conditions, HSP Duct is designed to manage high external static pressures up to 25mmAq.

25mmAq

20mmAq

11.2 ~ 14kW

SAMSUNG

General features

High External Static Pressare

SAMSUNG

Managing high external static pressures up to 25mmAq, this powerful HSP Duct provides a very large coverage area with outstanding cooling and heating performance. HSP Duct is an ideal fit for spaces with high ceilings, and can be flexibly installed in various environments.

Powerful and Flexible HSP Duct

Duct Type

22.4kW / 28kW

Strong and Large Coverage Area HSP duct features greater static pressure than most of slim ducts: this enables you to design more inlets and outlets with longer duct work to provide even more cool or warm air to larger areas.

0~6mmAq

Slim Duct

0~25mmAq

HSP Duct

Silent Operation with the Static Pressure Control The external static pressure control makes it easy to design the duct work to ensure efficiency and silent operation.

Easy to Maintain Time and maintenance costs are reduced since parts are easily accessible.

35 2012 SAMSUNG System Air Conditioner


Silent yet Strong

Concealed behind ceilings, MSP Duct provides powerful yet silent operation with external static pressure control. MSP Duct has a very large coverage area, thanks to the great static pressure that provides stable and efficient performance in larger areas.

General features

Silent yet Strong MSP Duct

Duct Type

Strong and Large Coverage Area MSP duct features greater static pressure than most of slim ducts: this enables you to design more inlets and outlets with longer duct work to provide even more cool or warm air to larger areas.

0~6mmAq

0~25mmAq

Slim Duct

MSP Duct

Silent Operation with the Static Pressure Control The external static pressure control makes it easy to design the duct work to ensure efficiency and silent operation.

Narrow Width MSP Duct has very narrow width of 900mm, which enables flexible installation and maintenance with its compact size, thus maximizing your convenience.

900mm 䋪䎰䏈䏄䏖䏘䏕䏈䏇䎃䏚䏌䏗䏋䏒䏘䏗䎃䏆䏒䏑䏗䏕䏒䏏䎃䏅䏒䏛䎑

Easy to Maintain Time and maintenance costs are reduced since parts are easily accessible.

37 2012 SAMSUNG System Air Conditioner


Diffuser

General features

The air inlet can be set up either on the bottom or rear of the unit, giving you greater flexibility in installation.

Diffuser

Slim Duct enables flexible installation options, and can be used for many differently shaped rooms with its rear and bottom side air inlets. Concealed behind ceilings, Slim Duct enhances the luxurious ambience of your space while providing fresh and powerful cool air.

Flexible Installation

TEX

TEX

Suction Duct

Suction Duct

Rear Side Air Inlet

Bottom Side Air Inlet

Slim Design Only 199mm thick, this slim design makes installation, maintenance and repair easy to perform.

Thick

Slim and Flexible

Slim and Flexible Slim Duct

Duct Type

225mm 220mm

199mm

SAMSUNG

Company B

Company A

Easier Drain Pump Installation /FX ESBJO QVNQ DBO CF JOTUBMMFE GSPN UIF TJEF CZ TJNQMZ removing the right side panel. You no longer need to disassemble the top cover to install, check or repair the drain pump.

Easy to Maintain Parts are easily accessible by simply opening the bottom panel, which reduces time and maintenance costs.

39 2012 SAMSUNG System Air Conditioner


Quiet and Efficient

93kg

This light and compact unit, with its shorter height of 390mm, enables you to conveniently install and manage it in a variety of areas and installation options.

35%

86kg

Lighter

0.55m3

51%

60kg

Smaller

0.38m3 0.27m3 Company B

Volume

TEX

Company A

SAMSUNG

390mm

Company B

Height

Company A

General features

Flexible Installation

SAMSUNG

Adopting a highly efficient BLDC motor, the new Fresh Air Intake Duct improves efficiency to the highest level, significantly reducing energy consumption and operation sound level to create a more pleasant and comfortable environment for you. Breathe real fresh air and stay healthy with the new Fresh Air Intake Duct.

Weight 䮝Comparison based on 5HP Duct.

Highly Efficient BLDC Motor 548W

The BLDC motor enables Fresh Air Intake Duct to perform at the highest efficiency possible, saving energy up to 32% for more economical and practical operation.

32% Saving 370W Company A

SAMSUNG

Quiet and Efficient Fresh Air Intake Duct

Duct Type

Energy Consumption 䮝Comparison based on 5HP Duct.

Quiet Operation Equipped with the highly efficient BLDC motor, Fresh Air Intake Duct operates quietly with a sound level as low as 42 Decibels, slightly higher than that of a library, to provide your environment with optimum comfort.

55dB(A)

42dB(A)

40dB(A)

Library

Fresh Air Intake Duct

Office

Noise Level 䮝Comparison based on 5HP Duct.

Flexible Static Pressure Control If the installation area of the duct exceeds the standard, then the static pressure control system maintains the optimized air volume, adjusting the fan speed.

Low Static Pressure

41

Standard

2012 SAMSUNG System Air Conditioner

High Static Pressure


Wall-mounted Type

Wall-mounted Type

Icon Description

Smart Inverter

Fresh and Pleasant

Samsung Smart Inverter technology saves up to 80% in energy while the air conditioner is on by maintaining the ideal temperature without constant shutting off and on of the compressor. Smart Inverter technology automatically adjusts power to cope with any temperature variances, assuring you have optimal comfort.

Neo Forte’s clean panel design with a unique silver accent adds a touch of class to your space. It also provides the efficient and stable cooling performance and maintains the optimum temperature, even while you sleep.

General features

Full HD Filter Improved dust removability!

Dust Collection up to

90%

Samsung’s Full HD Filter creates cleaner air with outstanding dust collection! Competitors’ Filter Dust Collection

40%

Internal EEV (Neo Forte-E) EEV (Electronic Expansion Valve) equipped inside the unit allows easy installation and maintenance.

good’sleep Best temperature for deep sleep 1 Falling asleep stage Eases you into sleep by dropping the temperature. 2 Sound sleep stage 3FMBYFT ZPVS CPEZ BOE SBJTFT ZPVS UFNQFSBUVSF slightly. 3 Wake up stage Allows you to wake up from comfortable intermittent air, making you feel refreshed.

Falling asleep

Sound sleep

Wake up

01

02

03

Temp.

3oC 2oC

Cooling mode

1oC Set Temp -1oC

Heating mode

-2oC

Till 1hr

1

2 to 7 hrs

2

3

Till 8 hrs

4

5

6

7

8 Time(hr.)

Unique Filter

2012 SAMSUNG System Air Conditioner

The multi filter system absorbs and eliminates microscopic harmful substances with unpleasant odors in the air.

43

%/" 'JMUFS Catechin Filter Deodorizing Filter


Simple yet Functional

Ceiling type indoor unit has two way installation options for the ceiling and floor, enabling you to use your available space more efficiently. You can enjoy crisp, powerful air spreading throughout your entire space from the compact unit in your ceiling or floor.

General features

Simple yet Functional Ceiling

Console & Ceiling Type

2Way Installation Depending on the available space and the purpose of the air conditioner, the indoor unit can be installed under the ceiling or on the floor.

Under Ceiling

Floor Standing

Compact but Powerful Samsung Ceiling type air conditioner boasts a slim, compact design - half the size of our competitor's with cooling power comparable to our competitor’s larger products.

200% 136% Smaller

123%

Lighter

118% 100%

100%

SAMSUNG

Company B

Company A

SAMSUNG

Company B

Company A

7.1kW Model

Size

Weight

45 2012 SAMSUNG System Air Conditioner


S-NET 3

Control System Structure

Remote Control

Control System

Internet

Convenient Management

Integrated Management

System Controller

Enabling convenient and optimized management, Samsung’s integrated management system is a perfect choice for managing large and middle-sized buildings with many indoor and outdoor units.

Samsung’s control system offers various control options for the indoor units. You can control the multiple units individually or simultaneously in groups to optimize your convenience.

Samsung System Air Conditioner’s various products are designed so that you can find the most convenient and efficient air conditioning system to perfectly suit your needs.

Featuring a touch screen, S-NET Mini can be directly connected to the system air conditioners through centralized controllers or interface modules.

DMS 2

Centralized Controller

DMS 2 is an internet-based management device that stores and manages all the data relevant to the system air conditioner.

The centralized controller controls the system air conditioners individually or in groups supporting many other functions.

Interface Module

Wired R/C , Wireless R/C

The interface module transmits data between the outdoor units and the upper level controllers.

The individual remote controllers are used to conrol single indoor units conveniently.

2012 SAMSUNG System Air Conditioner

This excellent building management system with convenient monitoring makes management of your air conditioning units much easier and economical.

Applications

S-NET Mini

This integrated software connects to the internet to control the system air conditioners through DMS from a single computer.

47

Building Management

S-NET 3


S-NET 3 manages a group of buildings through Data Management Servers (DMS 2) that individually manage each building, providing flexible and complete control for a wide variety of applications.

MST-P3P r 'VMMZ JOUFHSBUFE 1$ NBOBHFNFOU TPGUXBSF r 6Q UP %.4 DPOOFDUJPO UISPVHI UIF &UIFSOFU r $FOUSBM NBOBHFNFOU PG VQ UP JOEPPS VOJUT JODMVEJOH &37 &37 1-64 BOE ")6 r 4DIFEVMF ;POF DPOUSPM r &SSPS 0QFSBUJPO IJTUPSZ NBOBHFNFOU r 1PXFS EJTUSJCVUJPO NBOBHFNFOU BOE BOBMZTJT

S-NET 3 System

Supports16

Control and Monitoring

Power Distribution Management

t $POUSPM NPOJUPSJOH PG VQ UP JOEPPS VOJUT including ERV, ERV PLUS and AHU t 8JSFMFTT XJSFE SFNPUF DPOUSPM SFTUSJDUJPO

t %BUB RVFSZ GPS QPXFS EJTUSJCVUJPO BOE PQFSBUJPO UJNF

t 5FNQFSBUVSF MJNJU TFUUJOH t 0QFSBUJPO NPEF MPDL

t 5JNF TFDUJPO TFUUJOH GPS EJGGFSFOU FMFDUSJDJUZ SBUFT

t .VMUJQMF GVMM JOEPPS VOJU TFMFDUJPO

t (SPVQ TFUUJOH GPS QPXFS EJTUSJCVUJPO TVNNBSZ

t 1PXFS EJTUSJCVUJPO SFQPSU HFOFSBUJPO BOE QSJOUJOH

S-NET 3

Integrated and Complete

Integrated and Complete S-NET 3

Integrated Management

t *DPO CBTFE JOEPPS VOJU EJTQMBZ NPEF

Schedule Control

History Management

t (SBQIJDBM TDIFEVMF TFUUJOHT

t &SSPS &WFOU IJTUPSZ NBOBHFNFOU

t 8FFLMZ %BJMZ TDIFEVMF DPOUSPM

t *OEPPS VOJU PQFSBUJPO IJTUPSZ NBOBHFNFOU

t &YDFQUJPO EBUF TFUUJOH

t 3FQPSU HFOFSBUJPO BOE QSJOUJOH

Zone Management

Cycle Monitoring

t .BOBHFNFOU TUSVDUVSF DVTUPNJ[BUJPO SFHBSEMFTT of installation structure

t .POJUPSJOH PVUEPPS JOEPPS VOJU DZDMF EBUB (The monitoring function is supported for specific outdoor unit models)

t $POUSPM [POF DSFBUJPO FEJUJPO EFMFUJPO t 5SFF TUSVDUVSF [POF NBOBHFNFOU DPOUSPM

49 2012 SAMSUNG System Air Conditioner


4 /&5 .JOJ TVQQPSUT VQ UP %.4 UP QSPWJEF UIF TBNF SFNPUF DPOUSPM GVODUJPOT BT 4 /&5 This touch screen controller can be directly connected to the system air conditioner through the DFOUSBMJ[FE DPOUSPMMFS PS JOUFSGBDF NPEVMFT BMMPXJOH GPS UIF DPOUSPM PG VQ UP JOEPPS VOJUT

MST-S3W r 'MFYJCMF DPNQBUJCJMJUZ PQUJPOT %.4 DFOUSBMJ[FE DPOUSPMMFS JOUFSGBDF NPEVMF

r $FOUSBM NBOBHFNFOU PG VQ UP JOEPPS VOJUT JODMVEJOH &37 &37 1-64 BOE ")6 r %FUBJMFE DZDMJOH JOGPSNBUJPO NPOJUPSJOH r 4DIFEVMF GVODUJPO 8FFLMZ %BJMZ

r 64# LFZCPBSE TVQQPSU r &SSPS EJTQMBZ r JODI XJEF -$% EJTQMBZ

Control and Monitoring

Central Restriction Function

t $POUSPM NPOJUPSJOH PG VQ UP JOEPPS VOJUT including ERV, ERV PLUS and AHU

t 6QQFS -PXFS UFNQFSBUVSF MJNJU TFUUJOH t 0QFSBUJPO NPEF MPDL

t 0QFSBUJPO DPOUSPM BOE NPOJUPSJOH

S-NET Mini

Comprehensive and Solid

Comprehensive and Solid S-NET Mini

Integrated Management

t %FUBJMFE PQFSBUJPO DZDMJOH JOGPSNBUJPO NPOJUPSJOH t 8JSFMFTT XJSFE SFNPUF DPOUSPM SFTUSJDUJPO TFUUJOH

Schedule Control

Cycle Monitoring

t .BYJNVN 8FFLMZ %BJMZ TDIFEVMF DPOUSPM

t .POJUPSJOH PVUEPPS JOEPPS VOJU DZDMF EBUB (The monitoring function is supported for specific outdoor unit models)

t 4DIFEVMF SFQFUJUJPO FYDFQUJPO EBUF TFUUJOH t 4DIFEVMF FEJU BEE FEJU EFMFUF

r 5FNQFSBUVSF MJNJU TFUUJOH

t %FUBJMFE PQFSBUJPO TDIFEVMF TFUUJOH

r 5PVDI TDSFFO

t 3FNPUF DPOUSPM SFTUSJDUJPO PQUJPO TFUUJOH

r ;POF DPOUSPM r $IJME MPDL TFUUJOH r 0QFSBUJPO NPEF MPDL r &YUFSOBM DPOUBDU DPOUSPM

Dynamic Compatibility Option

Supports 4

Zone Management

Error Management

t .BOBHFNFOU TUSVDUVSF DVTUPNJ[BUJPO SFHBSEMFTT of installation structure

t &SSPS IJTUPSZ NBOBHFNFOU

t $POUSPM [POF DSFBUJPO FEJUJPO EFMFUJPO

t &SSPS NBOBHFNFOU JOGPSNBUJPO RVFSZ t %FUBJMFE FSSPS JOGPSNBUJPO RVFSZ

Supports16

51 2012 SAMSUNG System Air Conditioner

Supports16


The improved Data Management Server has become smarter: it can manage a variety of different air conditioning units, and the newly upgraded functions can automatically manage the air conditioning system for you.

MIM-D00A r #VJMU JO XFC TFSWFS GPS 1$ JOEFQFOEFOU NBOBHFNFOU and remote access control r .VMUJQMF VQQFS MFWFM DPOUSPM BDDFTT 4 /&5 4 /&5 .JOJ 8FC DMJFOU

DMS 2

Advanced and Smarter

Advanced and Smarter DMS 2

Integrated Management

Air-Conditioning Operation Monitoring t /P OFFE UP PQFO FBDI PVUEPPS VOJUT t %FUBJMFE SFGSJHFSBOU GMPX DIFDL JO DPOUSPM SPPN t 3FEVDFE TFSWJDF MFBE UJNF

r $FOUSBM NBOBHFNFOU PG VQ UP JOEPPS VOJUT JODMVEJOH &37 &37 1-64 BOE ")6 r 6TFS FEJUBCMF DPOUSPM MPHJD r "DDFTTJCMF MFWFM NBOBHFNFOU r %ZOBNJD TFDVSJUZ NBOBHFNFOU r 0QFSBUJPO FSSPS IJTUPSZ NBOBHFNFOU r 8FFLMZ %BJMZ TDIFEVMF DPOUSPM r 1PXFS EJTUSJCVUJPO GVODUJPO r $VSSFOU UJNF NBOBHFNFOU FWFO EVSJOH QPXFS GBJMVSF GPS IPVST

Easy Control & Monitoring

r %BUB TUPSBHF JO OPO WPMBUJMF NFNPSZ 4% NFNPSZ

t $POUSPM BOE NPOJUPSJOH PG VQ UP JOEPPS VOJUT WJB JOUFSOFU OFUXPSL

r &NFSHFODZ TUPQ GVODUJPO XJUI TJNQMF DPOUBDU JOUFSGBDF

t 0QFSBUJPO 0O 0GG t 0QFSBUJPO NPEF GBO TQFFE UFNQFSBUVSF TFUUJOH t &37 &37 1-64 ")6 TVQQPSU

DMS 2 System

Anytime, Anywhere

Control

Interface Module

Indoor Unit On/Off Time Storage PIM

Watt Hour Meter

t 0QFSBUJPO IJTUPSZ UIBU SFDPSET EBUB GPS VQ UP NPOUIT Storage parameters

53

1. Indoor unit address and name 0O 0GG UJNF ZFBS NPOUI EBZ IPVS NJOVUF

Interface Module

0QFSBUJPO NPEF $PPM )FBU "VUP 'BO %SZ 4UPQ

4FU 3PPN UFNQFSBUVSFT

PIM

Watt Hour Meter

2012 SAMSUNG System Air Conditioner

Storage Period 6Q UP NPOUIT Centralized Controller


DMS 2

Advanced and Smarter DMS 2

Flexible Connectivity

Enhanced Graphical Display

t *OEPPS VOJU DPOUSPM WJB DFOUSBMJ[FE DPOUSPMMFST or interface modules directly t 4FMFDU DPOOFDUJPO QPJOU BDDPSEJOH UP UIF TJUF

Color indication and icons make it easy to recognize indoor unit status

User-friendly icon-based unit control

Over 16 Outdoor Units

Under 16 Outdoor Units

PIM

PIM

4NBMM .FEJVN 4J[F

-BSHF 4J[F

Connect interface module directly.

Connect centralized controllers.

Convenient & stylish controller

Zoom in & Zoom out icon display

Accessible Level Management

Powerful Data Backup

t *U JT QPTTJCMF UP TQFDJGZ UIF TDPQF PG DPOUSPM BOE NPOJUPSJOH unit by each user.

t *NQPSUBOU EBUB JT TBGFMZ TUPSFE PO 4% NFNPSZ DBSE *OEPPS PVUEPPS VOJU OBNF 2. Power distribution data User_D

Administrator

0QFSBUJPO IJTUPSZ 0O 0GG CZ %.4

%.4 QPXFS 0O 0GG IJTUPSZ

Each user can only control and monitor the units which are allowed to access.

User_C

Automatic System Recovery after Service

4ZTUFN DPOGJHVSBUJPO 0UIFST

User_B User_A

Dynamic User Security Management "ENJO

6TFS

Manager

'VODUJPOT "DDFTT "MM

Changeable

0

0

0

;POF .BOBHFNFOU

0

0

X

Schedule

0

0

0

1PXFS %JTUSJCVUJPO

0

0

X

System Configuration

0

X

X

t & NBJM OPUJGJDBUJPO UP QSJWBUF JOUFSOFU BDDPVOU JO case of malfunction Malfunction E-mail

Remote Service

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

$POUSPM .POJUPSJOH

t 3FNPUF DPOUSPM BOE NPOJUPSJOH UISPVHI UIF *OUFSOFU (In case public IP is used)

55

54

(FOFSBM VTFST NBOBHFST BOE BENJOJTUSBUPST DBO CF SFHJTUFSFE separately by ID and password. Administrators (utility managers) have the authority to set access levels for DMS 2 functions on users.

Rapid & Easy Service Response


Indoor Unit Operation State 5th Floor

t 1PXFS EJTUSJCVUJPO UP B NBYJNVN PG JOEPPS VOJUT t 6TFS DBO FEJU DPOUSPM MPHJD XJUI BSJUINFUJD DPOEJUJPOBM PQFSBUPST BOE QBSBNFUFST t &OFSHZ DBO CF FGGJDJFOUMZ VTFE BOE SFEVDFE GPS WBSJPVT PQFSBUJPO DPOEJUJPOT

140kWh

t %BUB RVFSZ GPS XBUU IPVS VTBHF UJNF BOE VTBHF SBUJP

4th Floor

610kWh

t 'JMFT BSF TBWFE JO .JDSPTPGU &YDFM GPSNBU

3rd Floor

t ZFBS QPXFS EJTUSJCVUJPO EBUB JT TBWFE JO TUPSBHF

460kWh

t $VSSFOU BDUVBM QPXFS DPOTVNQUJPO NPOJUPSJOH

EHP / ERV / AHU Parameters 5FNQFSBUVSF 1PXFS .PEF

AND OR

Arithmetic Equation Function

EHP / ERV / AHU Parameters change

"WFSBHF

4FUUJOH UFNQ 1PXFS .PEF 'BO TQFFE

t $VSSFOU UZQF FMFDUSJDJUZ NFUFS TVQQPSU $5 SBUJP JOQVU

DMS 2

Advanced and Smarter DMS 2

Power Distribution System

User Editable Control Logic

2nd Floor

1. Operation Data Accumulation and Power Distribution

360kWh 1st Floor

180kWh 2. Data Extract - Excel Format

Example : Energy saving function, operation adjustment depending on outdoor temperature

Smart Central Management

Room Outdoor

WINTER

t $POUSPM NPOJUPSJOH [POF FEJUJPO

SUMMER

t 8JSFMFTT XJSFE SFNPUF DPOUSPM SFTUSJDUJPO

B Zone

t 5FNQFSBUVSF MJNJU TFUUJOH t 0QFSBUJPO NPEF SFTUSJDUJPO

Logic

Outdoor temp < Room temp

Room temp < Outdoor temp

Outdoor temp < 10

Outdoor temp > 25

Control

Turn ON ERV (Cool air Intake UP

Turn ON Air Conditioner

Heating mode

Cooling mode

A Zone

$PPMJOH POMZ /P SFNPUF DPOUSPMMFS .JOJNVN TFUUJOH UFNQFSBUVSF JO DPPMJOH JT 0C

B Zone

$PPMJOH POMZ 3FNPUF DPOUSPMMFS VTF

A Zone

Useful History Management t %.4 SFDPSET JOEPPS VOJU PQFSBUJPO BOE FSSPS occurrence history.

Operation History 0QFSBUJPO 0O 0GG FYFDVUJPO UJNF %BJMZ BDDVNVMBUFE PQFSBUJPO 0O UJNF 3. Schedule operation execution time

t 3FDPSEFE IJTUPSZ NBLFT JU DPOWFOJFOU UP BOBMZ[F air-conditioner operation and perform unit maintenance.

Error History 1. Error occurred unit name 2. Error details &SSPS PDDVSSFODF DMFBS UJNF &SSPS TUBUF TPMWFE VOTPMWFE

More Extended Contact Interface t *OUFSMPDLJOH XJUI FYUFSOBM FNFSHFODZ TZTUFN GPS emergency control

Building Control System

Operation Restriction

t 4ZTUFN PQFSBUJPO BOE FSSPS TJHOBM PVUQVU

57

56

t $POUBDU JOQVU BOE PVUQVU GPS JOUFSGBDF XJUI B HFOFSBM QVSQPTF EFWJDF .BYJNVN PG DPOUBDUT

t %JSFDU DPOUBDU PVUQVU DPOUSPM BOE JOQVU NPOJUPSJOH

Error Status Indicator

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Fire Control System


The centralized control system offers easy and convenient control of individual indoor units or entire groups of multiple units. You can control and manage multiple functions for the units by using a variety of controllers.

Line-up r $FOUSBMJ[FE $POUSPMMFS r 'VODUJPO $POUSPMMFS r 0QFSBUJPO .PEF 4FMFDUJPO 4XJUDI r *OUFSGBDF .PEVMF

Centralized Control

Flexible and Efficient

Flexible and Efficient Centralized Control

System Controller

Centralized Controller MCM-A202D t .BYJNVN PG HSPVQ DPOUSPMT .BYJNVN PG *OEPPS VOJUT

t 6OJGJFE *OEJWJEVBM JOEPPS VOJU DPOUSPM 0O 0GG

t 8JSFMFTT XJSFE SFNPUF DPOUSPM SFTUSJDUJPO t $PPMJOH )FBUJOH NPEF DPOUSPM t *OEPPS VOJU FSSPS EJTQMBZ .$. " % JT DPNQBUJCMF XJUI .$. " " BOE .$. " #

Function Controller MCM-A100 t 0O 0GG 0QFSBUJPO .PEF 'BO 4QFFE "JSGMPX 5FNQFSBUVSF TFUUJOH t &SSPS EJTQMBZ t 'JMUFS SFQMBDFNFOU BMBSN SFTFU t $POUSPM BOE NPOJUPSJOH PG VQ UP JOEPPS VOJU HSPVQT .$. " NVTU CF DPOOFDUFE UP .$. " % UP PQFSBUF

Operation Mode Selection Switch MCM-C200 t 0QFSBUJPO NPEF TFMFDUJPO $PPMJOH )FBUJOH PS "VUP

t .JYFE PQFSBUJPO NPEF QSPUFDUJPO

MCM-A100

Interface Module MCM-A202D

MIM-B13D

MIM-B13E

t $PNNVOJDBUPS CFUXFFO JOEPPS PVUEPPS VOJUT BOE the centralized controller

t $PNNVOJDBUPS CFUXFFO JOEPPS PVUEPPS VOJUT BOE the centralized controller

MCM-C200

2012 SAMSUNG System Air Conditioner

.*. # % TVQQPSUT UIF %7. '+. CAC, ERV and ERV PLUS.

59

.*. # % NVTU CF VTFE XIFO DPOUSPMMJOH B HSPVQ PG MFTT UIBO (If it is not used for group control, then .*. # % IBT UP CF VTFE

.*. # & JT DPNQBUJCMF XJUI .*. # " BOE .*. # # .*. # & NVTU CF VTFE XIFO DPOUSPMMJOH B HSPVQ PG NPSF UIBO .*. # & TVQQPSUT UIF %7. '+. $"$ BOE &37 (It doesn’t support ERV PLUS.)


The individual control system has a variety of wired and wireless controllers that enable you to easily control your air conditioners. You can choose the one that best suits your air conditioning environment.

Line-up r 8JSFMFTT 3FNPUF $POUSPMMFS r 8JSFE 3FNPUF $POUSPMMFS r 8JSFMFTT 4JHOBM 3FDFJWFS r 4JNQMJGJFE 8JSFE 3FNPUF $POUSPMMFS r &37 8JSFE 3FNPUF $POUSPMMFS r &YUFSOBM 3PPN 4FOTPS r EBZ 4DIFEVMFS

Wireless Remote Controller MR-DH00 t 0O 0GG 0QFSBUJPO .PEF 'BO 4QFFE "JSGMPX Temperature Setting t 'JMUFS SFQMBDFNFOU BMBSN SFTFU t 4JNQMF TDIFEVMF DPOUSPM t 8JEF EJTQMBZ

Individual Control

Convenient and Simple

Simple and Convenient Individual Control

System Controller

t 4PGU UPVDI CVUUPO t *OEJWJEVBM CMBEF DPOUSPM TVQQPSUT TQFDJGJD JOEPPS VOJU NPEFMT

t .VMUJ DIBOOFM XJSFMFTT SFNPUF DPOUSPM NBYJNVN PG DIBOOFMT

Wired Remote Controller MWR-WE10 t 0O 0GG 0QFSBUJPO .PEF 'BO 4QFFE "JSGMPX Temperature Setting t *OEJWJEVBM BOE HSPVQ DPOUSPM .BYJNVN UP JOEPPS VOJUT

t &SSPS EJTQMBZ t 'JMUFS SFQMBDFNFOU BMBSN SFTFU t 4MFFQ 4JMFOU NPEF t #VJMU JO 3PPN 5FNQFSBUVSF TFOTPS t $IJME MPDL t "VUPNBUJD TUPQ NPEF t 8JSFMFTT SFNPUF DPOUSPM SFTUSJDUJPO t $MFBS #SJHIU TDSFFO XJUI -$% CBDLMJHIU t 6OJGJFE DPOUSPMMFS "$ &37 &37 1-64 ")6

t %JGGFSFOU QFSNJTTJPO MFWFMT t 8FFLMZ TDIFEVMF TFUUJOH " $ &37 " $ &37

t &YDFQUJPO EBUF TFUUJOH t *OEJWJEVBM CMBEF DPOUSPM (Supported the specific indoor unit models) t 4VNNFS UJNF

MWR-WH00

MWR-WH0* t 0O 0GG 0QFSBUJPO .PEF 'BO 4QFFE "JSGMPX Temperature Setting t #VJMU JO 3PPN 5FNQFSBUVSF TFOTPS t $IJME MPDL

MWR-WE10

t "VUPNBUJD TUPQ NPEF t 4MFFQ 4JMFOU NPEF t 4JNQMF TDIFEVMF DPOUSPM

2012 SAMSUNG System Air Conditioner

MR-DH00

61

t %JGGFSFOU QFSNJTTJPO MFWFMT


Wireless Signal Receiver MRK-A00 t 0O 0GG control t 0QFSBUJPO JOEJDBUJPO

Unitive and Various

t &SSPS *OEJDBUJPO t 'JMUFS SFQMBDFNFOU TJHO t 6TF XJUI SFDFJWFS XJSF .38 "

Simplified Wired Remote Controller

5IF #VJMEJOH .BOBHFNFOU 4ZTUFN QSPWJEFT WBSJPVT DPOUSPM GVODUJPOT UP JOUFHSBUFEMZ NBOBHF UIF CVJMEJOH BJS DPOEJUJPOJOH TZTUFN 5IFTF NPEVMFT NBLF JU FBTZ UP DPOUSPM BOE NBOBHF WBSJPVT TZTUFN FRVJQNFOU BT XFMM BT UIF air conditioners to offer efficient and economical operating environment.

Building Management Module

Convenient and Simple Individual Control

Building Management

MWR-SH00 t 0O 0GG 0QFSBUJPO .PEF 'BO 4QFFE "JSGMPX Temperature Setting t *OEJWJEVBM BOE HSPVQ DPOUSPM .BYJNVN PG JOEPPS VOJUT

t &SSPS EJTQMBZ t 'JMUFS SFQMBDFNFOU BMBSN SFTFU t .PEF TFMFDUJPO QSPUFDUJPO

ERV Wired Remote Controller MWR-VH02 t *OEJWJEVBM BOE HSPVQ DPOUSPM .BYJNVN PG &37T

t 0O 0GG DPOUSPM t 0QFSBUJPO .PEF #Z 1BTT )FBU &YDIBOHF 'BO 4QFFE t 4JNQMF TDIFEVMF DPOUSPM t &SSPS EJTQMBZ t 4ZODISPOJ[FE PQFSBUJPO XJUI JOEPPS VOJUT

Watt-hour Meter Interface Module

External Room Sensor MRW-TA t &YUFSOBM TFOTPS UP TFOTF FYBDU VTFS FOWJSPONFOU temperature t 8JSF MFOHIU N

LonWorks gateway

7day Scheduler

63

62

MWR-BS00 t 6Q UP XFFLMZ BOE EBJMZ TDIFEVMF TFUUJOHT t 4DIFEVMF TFUUJOH CBTFE PO NJOVUF UJNF VOJUT

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

t %JHJUBM DMPDL EJTQMBZ t 1FSNBOFOU TDIFEVMF TFUUJOH TUPSBHF t $VSSFOU UJNF QSPUFDUJPO GSPN CMBDLPVU NBYJNVN PG EBZT

t 6TF XJUI XJSFE SFNPUF DPOUSPMMFS PS DFOUSBMJ[FE DPOUSPMMFS .$. " %

BACnet gateway


LonWorks gateway

MIM-B17 (DMS-Bnet)

MIM-B18 (DMS-Lnet)

8JUI UIF #.4 DPOUSPM BOE NPOJUPSJOH GVODUJPO #"$OFU HBUFXBZ NBLFT JU FBTZ UP DPOUSPM UIF BJS DPOEJUJPOJOH OFUXPSL JO WBSJPVT XBZT #"$OFU HBUFXBZ DBO DPOUSPM VQ UP JOEPPS VOJUT VTFE JO DPNCJOBUJPO XJUI 4 /&5 BOE 4 /&5 Mini.

-PO8PSLT HBUFXBZ JT BO JOUFSGBDF GPS -PO $POOFDUJPO UP -PO8PSLT management system, providing you with a more convenient way to manage ZPVS BJS DPOEJUJPOJOH TZTUFN *U DBO DPOUSPM B NBYJNVN PG JOEPPS VOJUT used in combination with S-NET 3 and S-NET Mini.

r *OUFSGBDF GPS #"$OFU NBOBHFNFOU TZTUFN

r *OUFSGBDF GPS -PO $POOFDUJPO UP -PO8PSLT NBOBHFNFOU TZTUFN

r .BYJNVN JOEPPS VOJUT QMVT &37T TVQQPSU XJUI B NBYJNVN PG JOUFSGBDF NPEVMFT

r .BY JOEPPS VOJUT QMVT &37T TVQQPSU XJUI B NBYJNVN PG JOUFSGBDF NPEVMFT

r $PNCJOBUJPOBM VTF PG #"$OFU BOE 4 /&5 4 /&5 .JOJ

r $PNCJOBUJPOBM VTF PG -PO8PSLT BOE 4 /&5 4 /&5 .JOJ

r *ODMVEFT %.4 GVODUJPOT

r *ODMVEFT %.4 GVODUJPOT

Control

Monitoring

Control

Building Management Module

Unitive and Various Building Management Module

BACnet gateway

Monitoring

r 0O 0GG DPOUSPM

r 'JMUFS BMBSN SFTFU

r 0O 0GG DPOUSPM

r 5IFSNP 0O 0GG

r 0O 0GG DPOUSPM

r 'JMUFS BMBSN SFTFU

r 0O 0GG DPOUSPM

r 5IFSNP 0O 0GG

r 0QFSBUJPO NPEF

r 6TFS DPOUSPM SFTUSJDUJPO

r 0QFSBUJPO NPEF

r 1PXFS EJTUSJCVUJPO

r 0QFSBUJPO NPEF

r 6TFS DPOUSPM SFTUSJDUJPO

r 0QFSBUJPO NPEF

r 1PXFS EJTUSJCVUJPO

r Temperature setting

r 0QFSBUJPO NPEF MPDL

r 4FU 3PPN UFNQFSBUVSF

r 0QFSBUJPO NPEF MPDL

r Temperature setting

r 0QFSBUJPO NPEF MPDL

r 4FU 3PPN UFNQFSBUVSF

r 0QFSBUJPO NPEF MPDL

r 'BO TQFFE EJSFDUJPO

r Set temperature limit

r 'BO TQFFE EJSFDUJPO

r Set temperature limit

r 'BO TQFFE EJSFDUJPO

r Set temperature limit

r 'BO TQFFE EJSFDUJPO

r Set temperature limit

r ERV operation mode

r Emergency stop

r ERV operation mode

r *O 0VU DPOUBDU TUBUF

r ERV operation mode

r Emergency stop

r ERV operation mode

r *O 0VU DPOUBDU TUBUF

r ERV fan speed

r 0VUQVU DPOUBDU DPOUSPM

r ERV fan speed

r Emergency stop

r ERV fan speed

r 0VUQVU DPOUBDU DPOUSPM

r ERV fan speed

r Emergency stop

r 'JMUFS BMBSN

r Error code

r 'JMUFS BMBSN

r Error code

r 6TFS DPOUSPM SFTUSJDUJPO

r 6TFS DPOUSPM SFTUSJDUJPO

Connection

Connection

RS485

RS485

Ethemet

Ethemet

FTT-10A

Ethemet

Supports Max.80

Supports Max.80

LonWork BMS

65

64

BACnet BMS

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner


Guest Romm Management Module

Unitive and Various Building Management Module

Building Management

Watt-hour Meter Interface Module MIM-B16 PIM (Pulse Input Module)

Energy Conservational

8BUU IPVS .FUFS *OUFSGBDF .PEVMF DBO CF FYDMVTJWFMZ VTFE GPS %.4 QPXFS distribution, displaying power consumption for each watt-hour meter.

r &YDMVTJWF VTF GPS %.4 QPXFS EJTUSJCVUJPO r $POOFDUJPO XJUI VQ UP XBUU IPVS NFUFST

Guest Room Management system saves you energy and money on cooling an unoccupied room: the air-conditioner is activated when Key-Tag is in place and turns off when Key-Tag is removed.

r 1VMTF JOUFSGBDF XJUI XBUU IPVS NFUFST r 1PXFS DPOTVNQUJPO EJTQMBZ GPS FBDI XBUU IPVS NFUFS

Key Tag Interface Module

Connectable Watt-hour meter with PIM 8I 1VMTF 3BOHF _ 8I 1VMTF OP EFDJNBM QMBDF

MIM-B02

1VMTF 8JEUI 3BOHF _ NT

r *OEPPS VOJU DPOUSPM CZ FYUFSOBM DPOUBDU TJHOBMT

*OUFSWBM CFUXFFO 1VMTFT .JOJNVN PG NT

r *OEJWJEVBM (SPVQ DPOUSPM PG VQ UP JOEPPS VOJUT r $PNCJOBUJPOBM VTF XJUI TFOTPS UJNFS FNFSHFODZ JOQVUT

Short

Short

Open

Example

Short

Room 501

Room 502

Room 503

Room 504

Key-Holder

Key-Holder

Key-Holder

Key-Holder

Open

More than 3ms (Mandatory)

External Contact Interface Module

Connection

MIM-B14 Supports Max.8

r %JSFDU JOEPPS VOJU DPOUSPM CZ FYUFSOBM DPOUBDU TJHOBM

PIM

r 8JOEPX TZODISPOJ[FE JOEPPS VOJU DPOUSPM r &NFSHFODZ DPOUSPM XJUI TJNQMF DPOUBDU JOQVU r *OEPPS VOJU PQFSBUJPO FSSPS TUBUF PVUQVU UISPVHI SFMBZ contacts

Example (Wall-mounted Type Indoor Units : Only models that include EEV support state output function.)

Outdoor Unit

67

66

Supports Max.8

Indoor Unit

Key-Tag

On/Off

Window Open Sensor

Error

Malfunction Alarm

On/Off

Extemal Device Control

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

On/Off


Applications

Advanced and Versatile

Efficiency Improving

/FX %7. 1SP JT BO BEWBODFE EFTJHO BVUPNBUJPO UPPM UIBU DBO CF VTFE JO "VUP$"% CBTFE $"% NPEF PS 8JOEPXT CBTFE 4BMFT NPEF 5IJT OFX QSPHSBN IFMQT ZPV JO TFMFDUJOH TZTUFN BJS DPOEJUJPOFS FRVJQNFOU TP UIBU ZPV DBO easily and precisely design your air conditioning system.

")6 LJU BMMPXT %7. 1-64 *7 PVUEPPS VOJUT UP DPOOFDU UP ")6 "JS )BOEMJOH 6OJUT XIJDI SFTVMUT JO FOFSHZ TBWJOHT and improvement in performance and efficiency.

AHU Kit

Applications

Features

Sales mode t *OEPPS 6OJU 0VUEPPS 6OJU *OEPPS VOJU BOE PVUEPPS VOJU DPOOFDUJPO XJUI BDDFTTPSZ

MXD-A16K1X025A / A22K1X050A / A22K2X075A / A22K2X100A

t 1JQJOH #BTJD PS NBOVBM TFMFDUJPO XJUI TZTUFN DIFDL BOE DBQBDJUZ TJNVMBUJPO

t *1 JT TBUJTGJFE

t 8JSJOH "VUPNBUJD EJBHSBN XJUI DPNNVOJDBUJPO XJSJOH PG JOEPPS PVUEPPS DPOUSPM VOJUT BOE FMFDUSJD QPXFS NFUFST

t 7BSJBCMF $BQBDJUZ )1 )1 )1 )1

t $POUSPM TZTUFN "VUPNBUJD DPOUSPM VOJU TFMFDUJPO

t 4JNQMF #.4 DBO CF BQQMJFE

t 3FQPSU 4QFDJGJDBUJPOT EJBHSBNT XJUI %8( #.1 GPSNBU RVPUBUJPO

_ 7 DPOUSPM

Download! www.dvmsystem.com

Download Center

Software

NEW DVM-Pro

Outdoor unit

Communication F1, F2 EEV Kit

* Contact the administrator for authorization to download the program.

CAD mode t 2VJDL &BTZ 1SFDJTF %FTJHO

EEV Control Liquid Pipe

t "VUP$"% BEE PO TPGUXBSF "VUP$"% JT OPU JODMVEFE JO /FX %7. 1SP

t "VUPNBUJD $BMDVMBUJPO 3FGSJHFSBOU ESBJO QJQF TJ[F t "VUPNBUJD 4FMFDUJPO 3FGOFU KPJOU IFBEFS EJTUSJCVUPS LJU t 4ZTUFN $IFDL *OTUBMMBUJPO SFHVMBUJPO SFGSJHFSBOU BEEJUJPO AHU Fan Control

t &BTZ $POUSPM 4ZTUFN 4FMFDUJPO t "VUPNBUJD 3FQPSU 1JQJOH JOTUBMMBUJPO EJBHSBN FRVJQNFOU MJTU RVPUBUJPO

Retum Air Exhaust Air Fresh Air

Eva_in Sensor

Supply Air

Room Sensor

Eva_out Sensor

Contact to Samsung HQ or Distributors for NEW DVM-Pro!

2012 SAMSUNG System Air Conditioner

AHU Controller

Gas pipe

69

Fan Feedback


Contents System LINEUP & FEATURE

72

SPECIFICATION

76

Control System & Accessories CONTROL SYSTEM

105

ACCESSORIES

106

System Air Conditioner

SAMSUNG SAMSUNG 2012 SYSTEM AIR CONDITIONER

71


Lineup - Outdoor Units SINGLE IMAGE

MODEL

CAPACITY

8

10

RD080HQXHA

8 HP

1

RD100HQXHA

10 HP

RD120HQXHA

12 HP

RD140HQXHA

14 HP

RD160HQXHA

16 HP

MODEL

CAPACITY

RD080HQXHA

8 HP

RD100HQXHA

10 HP

1

RD120HQXHA

12 HP

1

RD140HQXHA

14 HP

RD160HQXHA

16 HP

MODULE

12

14

16

18

20

22

24

26

30

32

1

1 1

1

2

1 1

1

1

2

1 1

40

36

1

2

1

1

2

1 1

38

34 1

MODULE IMAGE

28

System

System

DVM Desert

1

1

2

1

1

56

58

60

62

64

2

1

1

2

1

2

2

3

MODULE 42

44

46

48

50

52

54

2

1

1

1

1

2

1

1

1

1

2

1

1

1

2

3

2

2

2

2

4

72

73

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner


Lineup & Feature - Indoor Units System

System

Cassette

Wall-mounted MODEL

MODEL

Neo Forte

Slim 1Way

4Way Cassette S

2Way

2.2

2.8

2.8 3.6

3.6

CAPACITY

4.5

4.5 CAPACITY (kW)

Neo Forte-E

2.2

5.6

5.6

7.1

7.1

8.3

Full HD Filter

9.0 11.2 12.8

Deodorizing Filter

14.0

FEATURES

Wide

2QYGTHWN #KTĆ€QY

Smart Inverter

Wide Blade

Ceiling Dust Prevention

good' sleep

NO! Dust

FEATURES

Fresh Air Intake Fresh Air

High

High Lift-Up Drain Pump

High Lift -UP

Sub Duct Sub Duct

Duct

Ceiling MODEL

MODEL

Ceiling HSP

MSP

Slim

Fresh Air Intake

5.6

CAPACITY

7.1

2.2 2.8 3.6

Good Design

Interior Design

Interior Design

4.5 5.6 7.1

Anti-virus Filter Anti-virus Filter

9.0

CAPACITY

Lightweight Unit

10.0 11.2

Light Weight

12.8 14.0

Flexible Pipe Installation Flexible

22.4 28.0

Easy Filter

High

High Lift-Up Drain Pump

High Lift -UP

Smart Pressure Control Smart Control

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Easy Filter Cleaning FEATURES

75

74

Anti-virus Filter Anti-virus Filter


Specification - Outdoor Units

Model Name

DVM PLUS IV HP

Power Supply Mode

Cooling Performance

Capacity (Nominal)

Cooling 46°C Heating

Power Input (Nominal) Power

Reliable Operation in 54 C High Ambient Condition High Efficiency Large Capacity Advanced and Reliable Protection Easy Installation & Maintenance Eco-friendly Pleasant Operation O

COP

Fan

Piping Connections

DVM PLUS IV HP

Mode HP Cooling Performance

Capacity (Nominal)

Cooling 46°C

Power

COP

Current Input (Nominal)

Sound

Operating Temp. Range

95,500

kW Btu/h kW Btu/h

Cooling Cooling 46°C

kW

22.4

25.0

76,400

85,300

25.2

31.5

86,000

107,500

5.15

7.00

6.90

8.63

Heating

5.23

7.00

Cooling

11.0

13.8

Cooling 46°C

A

Heating

13.3

16.4

11.4

14.3 27.5

A

25

A

30

30

-

4.35

4.00

Nominal Cooling Nominal Heating

-

4.82

4.50

Type

-

Propeller Fan / BLDC

Propeller Fan / BLDC 210

Air Flow Rate

CMM

173

mmAq

8

8

Liquid Pipe

Ɏ, mm

9.52

9.52

Gas Pipe

Ɏ, mm

19.05

22.23

Oil Equalizing Pipe

Ɏ, mm

-

-

m

200

200

m

110 (40)*

110 (40)*

Max.

Max. Length Max. Height

Power cable

mm2

-

-

Communication cable

mm2

0.75~1.5

0.75~1.5

R410A

R410A

5.0

5.0

Type

-

Factory Charging

kg

Sound Pressure

dB(A)

Net Weight

kg

221

231

External Dimension

Shipping Weight

kg

238

248

Net Dimensions (WxHxD)

mm

880 x 1695 x 765

880 x 1695 x 765

Shipping Dimensions (WxHxD)

mm

948 x 1857 x 832

948 x 1857 x 832

Cooling

°C

-5 ~ 54

-5 ~ 54

Heating

°C

-20 ~ 24

-20 ~ 24

RD120HQXHA

RD140HQXHA

RD160HQXHA

RD180HQXHA

RD200HQXHA

Ɏ, #, V, Hz

3, 4, 380, 60

3, 4, 380, 60

3, 4, 380, 60

3, 4, 380, 60

3, 4, 380, 60

-

Heat Pump

Heat Pump

Heat Pump

Heat Pump

Heat Pump

HP

12

14

16

18

20

kW

33.6

39.2

44.8

50.4

56

114,600

133,800

152,900

172,000

191,100

Btu/h kW Btu/h kW

28.9

35.3

40.3

47.4

50

98,600

120,400

137,500

161,700

170,600

43.9

50.0

56.7

63

149,800

170,600

193,500

215,000

8.12

9.55

11.05

12.15

14

9.50

12.05

14.40

15.53

17.26

Heating

8.13

9.55

11.10

12.23

14

Cooling

14.9

16.9

19.2

24.8

27.6

Btu/h

Cooling Cooling 46°C

Cooling 46°C

kW

A

Heating

16.9

21.3

24.4

29.7

32.8

14.9

17.5

21.9

25.7

28.6

A

32.5

33.1

43.9

52.5

55

A

40

40

50

60

60

Nominal Cooling

-

4.14

4.10

4.05

4.15

4

Nominal Heating

-

4.65

4.60

4.50

4.64

4.5

-

Propeller Fan / BLDC

Propeller Fan / BLDC

Propeller Fan / BLDC

Propeller Fan / BLDC

Propeller Fan / BLDC

CMM

250

270

275

383

420

mmAq

8

8

8

8

8

Liquid Pipe

Ɏ, mm

12.70

12.70

12.70

15.88

15.88

Gas Pipe

Ɏ, mm

28.58

28.58

28.58

28.58

28.58

Oil Equalizing Pipe

Ɏ, mm

-

-

-

6.35

6.35

Air Flow Rate Max.

Max. Length

m

200

200

200

200

200

Max. Height

m

110 (40)*

110 (40)*

110 (40)*

110 (40)*

110 (40)*

Power cable

mm2

-

-

-

-

-

Communication cable

mm2

0.75~1.5

0.75~1.5

0.75~1.5

0.75~1.5

0.75~1.5

R410A

R410A

R410A

R410A

R410A

7.0

7.0

7.0

(5.0) x 2

(5.0) x 2 (231) x 2

Type Factory Charging Sound Pressure

kg dB(A)

Net Weight

kg

285

285

326

(221) x 1 + (231) x 1

Shipping Weight

kg

305

305

346

(238) x 1 + (248) x 1

(248) x 2

Net Dimensions (WxHxD)

mm

1295 x 1695 x 765

1295 x 1695 x 765

1295 x 1695 x 765

(880 x 1695 x 765) x 2

(880 x 1695 x 765) x 2

Shipping Dimensions (WxHxD)

(948 x 1857 x 832) x 2

mm

1363 x 1857 x 832

1363 x 1857 x 832

1363 x 1857 x 832

(948 x 1857 x 832) x 2

Cooling

°C

-5 ~ 54

-5 ~ 54

-5 ~ 54

-5 ~ 54

-5 ~ 54

Heating

°C

-20 ~ 24

-20 ~ 24

-20 ~ 24

-20 ~ 24

-20 ~ 24

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * The maximum height of installation limitation for piping connections is only allowable when using PDM kits.

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

External Dimension

76,400

Btu/h

77

76

Refrigerant

28.0

MCA

Installation Limitation Field Wiring

22.4

MFA

External Static Pressure

Piping Connections

10

kW

37.8

Type Fan

8

129,000

Heating Power Input (Nominal)

Heat Pump

HP

Sound

Operating Temp. Range

Power Supply

Heat Pump

MFA

Installation Limitation Field Wiring

3, 4, 380, 60

-

MCA

External Static Pressure

Refrigerant

Model Name

Current Input (Nominal)

RD100HQXHA

3, 4, 380, 60

System

System

HP

RD080HQXHA

Ɏ, #, V, Hz


Specification - Outdoor Units

Model Name

DVM PLUS IV HP

Power Supply Mode

Cooling Performance

Capacity (Nominal)

Cooling 46°C Heating

Power Input (Nominal) Power

Reliable Operation in 54 C High Ambient Condition High Efficiency Large Capacity Advanced and Reliable Protection Easy Installation & Maintenance Eco-friendly Pleasant Operation O

COP

Fan

Piping Connections

Sound External Dimension Operating Temp. Range

DVM PLUS IV HP

Power Supply Mode HP Cooling Performance

Capacity (Nominal)

Cooling 46°C Heating

COP

Sound

Operating Temp. Range

210,200

229,300

Btu/h kW Btu/h kW Btu/h

Cooling Cooling 46°C

kW

Heating Cooling Cooling 46°C

A

Heating

53.9

57.8

183,900

197,200

69.3

75.6

236,500

258,000

15.12

16.24

18.13

19

15.13

16.26

28.7

29.8

33.3

33.8

29.2

29.8

60

65

MFA

A

60

60

-

4.07

4.14

Nominal Cooling Nominal Heating

-

4.58

4.65

Type

-

Propeller Fan / BLDC

Propeller Fan / BLDC 500

Air Flow Rate

CMM

460

mmAq

8

8

Liquid Pipe

Ɏ, mm

15.88

15.88

Gas Pipe

Ɏ, mm

28.58

28.58

Oil Equalizing Pipe

Ɏ, mm

6.35

6.35

Max. Length

m

200

200

Max. Height

m

110 (40)*

110 (40)*

Max.

Power cable

mm2

-

-

Communication cable

mm2

0.75~1.5

0.75~1.5

Type

-

Factory Charging Sound Pressure

kg

R410A

R410A

(5.0) x 1 + (7.0) x 1

(7.0) x 2 (285) x 2

dB(A)

Net Weight

kg

(231) x 1 + (285) x 1

Shipping Weight

kg

(248) x 1 + (305) x 1

(305) x 2

Net Dimensions (WxHxD)

mm

(880 x 1695 x 765) x 1 + (1295 x 1695 x 765) x 1

(1295 x 1695 x 765) x 2

Shipping Dimensions (WxHxD)

(1363 x 1857 x 832) x 2

mm

(948 x 1857 x 832) x 1 + (1363 x 1857 x 832) x 1

Cooling

°C

-5 ~ 54

-5 ~ 54

Heating

°C

-20 ~ 24

-20 ~ 24

RD260HQXHA

RD280HQXHA

RD300HQXHA

RD320HQXHA

RD340HQXHA

3, 4, 380, 60

3, 4, 380, 60

3, 4, 380, 60

3, 4, 380, 60

3, 4, 380, 60

-

Heat Pump

Heat Pump

Heat Pump

Heat Pump

Heat Pump

HP

26

28

30

32

34

kW

72.8

78.4

84

89.6

95.2

248,400

267,500

286,600

305,700

324,800

64.2

70.6

75.6

80.6

87.7

219,100

240,900

258,000

275,000

299,200

Btu/h kW Btu/h kW Btu/h

81.7

87.8

93.9

100

106.7

278,800

299,600

320,400

341,200

364,100

19.1

20.6

22.1

23.2

26.45

28.8

29.93

Heating

17.68

19.1

20.65

22.2

23.33

Cooling

31.8

33.8

36.1

38.4

44

A

38.2

42.6

45.7

48.8

54.1

32.4

35

39.4

43.8

47.6

MCA

A

65.6

66.3

77

87.8

96.4

MFA

A

60

60

75

100

100

Nominal Cooling

-

4.12

4.1

4.08

4.05

4.1

Nominal Heating

-

4.62

4.6

4.55

4.5

4.57

-

Current Input (Nominal)

Cooling 46°C

Cooling 46°C

kW

Heating

Propeller Fan / BLDC

Propeller Fan / BLDC

Propeller Fan / BLDC

Propeller Fan / BLDC

Propeller Fan / BLDC

CMM

520

540

545

550

658

mmAq

8

8

8

8

8

Liquid Pipe

Ɏ, mm

19.05

19.05

19.05

19.05

19.05

Gas Pipe

Ɏ, mm

34.90

34.90

34.90

34.90

34.90

Oil Equalizing Pipe

Ɏ, mm

6.35

6.35

6.35

6.35

6.35

Max. Length

m

200

200

200

200

200

Max. Height

m

110 (40)*

110 (40)*

110 (40)*

110 (40)*

110 (40)*

Air Flow Rate Max.

Power cable

mm2

-

-

-

-

-

Communication cable

mm2

0.75~1.5

0.75~1.5

0.75~1.5

0.75~1.5

0.75~1.5

Type Factory Charging Sound Pressure

-

R410A

R410A

R410A

R410A

R410A

kg

(7.0) x 2

(7.0) x 2

(7.0) x 2

(7.0) x 2

(5.0) x 2 + (7.0) x 1 (221) x 1 + (231) x 1 + (326) x 1

dB(A)

Net Weight

kg

(285) x 2

(285) x 2

(285) x 1 + (326) x 1

(326) x 2

Shipping Weight

kg

(305) x 2

(305) x 2

(305) x 1 + (346) x 1

(346) x 2

(238) x 1 + (248) x 1 + (346) x 1

Net Dimensions (WxHxD)

mm

(1295 x 1695 x 765) x 2

(1295 x 1695 x 765) x 2

(1295 x 1695 x 765) x 2

(1295 x 1695 x 765) x 2

(880 x 1695 x 765) x 2 + (1295 x 1695 x 765) x 1

Shipping Dimensions (WxHxD)

(880 x 1695 x 765) x 2 + (1295 x 1695 x 765) x 1

mm

(1363 x 1857 x 832) x 2

(1363 x 1857 x 832) x 2

(1363 x 1857 x 832) x 2

(1363 x 1857 x 832) x 2

Cooling

°C

-5 ~ 54

-5 ~ 54

-5 ~ 54

-5 ~ 54

-5 ~ 54

Heating

°C

-20 ~ 24

-20 ~ 24

-20 ~ 24

-20 ~ 24

-20 ~ 24

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * The maximum height of installation limitation for piping connections is only allowable when using PDM kits.

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

External Dimension

67.2

79

78

Refrigerant

61.6

24.1

Installation Limitation Field Wiring

24

kW

17.67

External Static Pressure

Piping Connections

22

Ɏ, #, V, Hz

Cooling

Type Fan

Heat Pump

HP

21.55

Power Input (Nominal) Power

Heat Pump

A

Installation Limitation Field Wiring

3, 4, 380, 60

-

MCA

External Static Pressure

Refrigerant

Model Name

Current Input (Nominal)

RD240HQXHA

3, 4, 380, 60

System

System

HP

RD220HQXHA

Ɏ, #, V, Hz


Specification - Outdoor Units

Model Name

DVM PLUS IV HP

Power Supply Mode

Cooling Performance

Capacity (Nominal)

Cooling 46°C Heating

Reliable Operation in 54 C High Ambient Condition High Efficiency Large Capacity Advanced and Reliable Protection Easy Installation & Maintenance Eco-friendly Pleasant Operation O

COP

Fan

Refrigerant Sound External Dimension Operating Temp. Range

Model Name

DVM PLUS IV HP

Power Supply Mode HP Cooling Performance

Capacity (Nominal)

Cooling 46°C

Power

COP

Fan

Current Input (Nominal)

Sound

Operating Temp. Range

343,900

363,100

Btu/h kW Btu/h kW Btu/h

94.2

308,100

321,400

113

119.3

385,600

407,100 26.17

Heating

25.1

26.23

Cooling

46.8

47.9

A

57.2

57.7

50.5

51.1

MCA

A

98.9

103.9

MFA

Current Input (Nominal)

Cooling

90.3

Cooling 46°C

Cooling 46°C

kW

Heating A

100

100

Nominal Cooling

-

4.02

4.07

Nominal Heating

-

4.5

4.55

Type

-

Propeller Fan / BLDC

Propeller Fan / BLDC 735

Air Flow Rate

CMM

695

mmAq

8

8

Liquid Pipe

Ɏ, mm

19.05

19.05

Gas Pipe

Ɏ, mm

41.28

41.28

Oil Equalizing Pipe

Ɏ, mm

6.35

6.35

Max. Length

m

200

200

Max. Height

m

110 (40)*

110 (40)*

Max.

Power cable

mm2

-

-

Communication cable

mm2

0.75~1.5

0.75~1.5

Type

-

Factory Charging Sound Pressure

kg

R410A

R410A

(5.0) x 2 + (7.0) x 1

(5.0) x 1 + (7.0) x 2

dB(A)

Net Weight

kg

(231) x 2 + (326) x 1

(231) x 1 + (285) x 1 + (326) x 1

Shipping Weight

kg

(248) x 2 + (346) x 1

(248) x 1 + (305) x 1 + (346) x 1

Net Dimensions (WxHxD)

mm

(880 x 1695 x 765) x 2 + (1295 x 1695 x 765) x 1

(880 x 1695 x 765) x 1 + (1295 x 1695 x 765) x 2

Shipping Dimensions (WxHxD)

mm

(948 x 1857 x 832) x 2 + (1363 x 1857 x 832) x 1

(948 x 1857 x 832) x 1 + (1363 x 1857 x 832) x 2

Cooling

°C

-5 ~ 54

-5 ~ 54

Heating

°C

-20 ~ 24

-20 ~ 24

RD400HQXHA

RD420HQXHA

RD440HQXHA

RD460HQXHA

RD480HQXHA

Ɏ, #, V, Hz

3, 4, 380, 60

3, 4, 380, 60

3, 4, 380, 60

3, 4, 380, 60

3, 4, 380, 60

-

Heat Pump

Heat Pump

Heat Pump

Heat Pump

Heat Pump

HP

40

42

44

46

48

kW

112

117.6

123.2

128.8

134.4

382,200

401,300

420,400

439,500

458,600

98.1

104.5

110.9

115.9

120.9

334,700

356,600

378,400

395,500

412,500

Btu/h kW Btu/h kW

125.6

131.7

137.8

143.9

150

449,400

470,200

491,000

511,800

27.29

28.72

30.15

31.65

33.15

33.4

35.95

38.5

40.85

43.2

Heating

27.36

28.78

30.2

31.75

33.3

Cooling

49

51

53

55.3

57.6

Btu/h

Cooling Cooling 46°C

Cooling 46°C

kW

A

Heating

58.2

62.6

67

70.1

73.2

51.7

54.3

56.9

61.3

65.7 131.6

A

108.9

109.5

110.1

120.9

A

100

100

100

125

125

-

4.1

4.09

4.09

4.07

4.05

Nominal Cooling Nominal Heating

-

4.59

4.58

4.56

4.53

4.5

Type

-

Propeller Fan / BLDC

Propeller Fan / BLDC

Propeller Fan / BLDC

Propeller Fan / BLDC

Propeller Fan / BLDC 825

Air Flow Rate

CMM

775

795

815

820

mmAq

8

8

8

8

8

Liquid Pipe

Ɏ, mm

19.05

19.05

19.05

19.05

19.05

Gas Pipe

Ɏ, mm

41.28

41.28

41.28

41.28

41.28

Oil Equalizing Pipe

Ɏ, mm

6.35

6.35

6.35

6.35

6.35

Max. Length

m

200

200

200

200

200

Max. Height

m

110 (40)*

110 (40)*

110 (40)*

110 (40)*

110 (40)*

Max.

Power cable

mm2

-

-

-

-

-

Communication cable

mm2

0.75~1.5

0.75~1.5

0.75~1.5

0.75~1.5

0.75~1.5

Type Factory Charging Sound Pressure

-

R410A

R410A

R410A

R410A

R410A

kg

(7.0) x 3

(7.0) x 3

(7.0) x 3

(7.0) x 3

(7.0) x 3 (326) x 3

dB(A)

Net Weight

kg

(285) x 2 + (326) x 1

(285) x 2 + (285) x 1

(285) x 2 + (326) x 1

(285) x 1 + (326) x 2

Shipping Weight

kg

(305) x 2 + (346) x 1

(305) x 2 + (305) x 1

(305) x 2 + (346) x 1

(305) x 1 + (346) x 2

(346) x 3

Net Dimensions (WxHxD)

mm

(1295 x 1695 x 765) x 3

(1295 x 1695 x 765) x 3

(1295 x 1695 x 765) x 3

(1295 x 1695 x 765) x 3

(1295 x 1695 x 765) x 3

Shipping Dimensions (WxHxD)

(1363 x 1857 x 832) x 3

mm

(1363 x 1857 x 832) x 3

(1363 x 1857 x 832) x 3

(1363 x 1857 x 832) x 3

(1363 x 1857 x 832) x 3

Cooling

°C

-5 ~ 54

-5 ~ 54

-5 ~ 54

-5 ~ 54

-5 ~ 54

Heating

°C

-20 ~ 24

-20 ~ 24

-20 ~ 24

-20 ~ 24

-20 ~ 24

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * The maximum height of installation limitation for piping connections is only allowable when using PDM kits.

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

External Dimension

106.4

81

80

Refrigerant

100.8

MCA

Installation Limitation Field Wiring

38

kW

MFA

External Static Pressure

Piping Connections

36

428,600

Heating Power Input (Nominal)

Heat Pump

HP

32.53

Installation Limitation Field Wiring

Heat Pump

25.05

External Static Pressure

Piping Connections

3, 4, 380, 60

-

31.66

Power Input (Nominal) Power

RD380HQXHA

3, 4, 380, 60

System

System

HP

RD360HQXHA

Ɏ, #, V, Hz


Specification - Outdoor Units

Model Name

DVM PLUS IV HP

Power Supply Mode

Cooling Performance

Capacity (Nominal)

Reliable Operation in 54 C High Ambient Condition High Efficiency Large Capacity Advanced and Reliable Protection Easy Installation & Maintenance Eco-friendly Pleasant Operation

Fan

Model Name

DVM PLUS IV HP

Power Supply Mode HP Cooling Performance

Capacity (Nominal)

Cooling 46°C Heating

Power Input (Nominal) Power

COP

Fan

Current Input (Nominal)

Sound

Operating Temp. Range

156.7

163

534,700

556,200

34.43

36.2

Cooling

63.2

66

A

78.5

81.6

69.5

72.4

MCA

A

140.3

MFA

Cooling 46°C

kW

Heating A

125

Nominal Cooling

-

4.09

Nominal Heating

-

4.55

4.5

Type

-

Propeller Fan / BLDC

Propeller Fan / BLDC 970

4.03

CMM

933

mmAq

8

8

Liquid Pipe

Ɏ, mm

19.05

19.05

Gas Pipe

Ɏ, mm

41.28

41.28

Oil Equalizing Pipe

Ɏ, mm

6.35

6.35

Max. Length

m

200

200

Max. Height

m

110 (40)*

110 (40)*

Max.

Power cable

mm2

-

-

Communication cable

mm2

0.75~1.5

0.75~1.5

kg

R410A

R410A

(5.0) x 2 + (7.0) x 2

(5.0) x 2 + (7.0) x 2

dB(A)

Net Weight

kg

(221) x 1 + (231) x 1 + (326) x 2

(231) x 2 + (326) x 2

Shipping Weight

kg

(238) x 1 + (248) x 1 + (346) x 2

(248) x 2 + (346) x 2

Net Dimensions (WxHxD)

mm

(880 x 1695 x 765) x 2 + (1295 x 1695 x 765) x 2

(880 x 1695 x 765) x 2 + (1295 x 1695 x 765) x 2

Shipping Dimensions (WxHxD)

mm

(948 x 1857 x 832) x 2 + (1363 x 1857 x 832) x 2

(948 x 1857 x 832) x 2 + (1363 x 1857 x 832) x 2

Cooling

°C

-5 ~ 54

-5 ~ 54

Heating

°C

-20 ~ 24

-20 ~ 24

RD540HQXHA

RD560HQXHA

RD580HQXHA

RD600HQXHA

RD620HQXHA

RD640HQXHA

Ɏ, #, V, Hz

3, 4, 380, 60

3, 4, 380, 60

3, 4, 380, 60

3, 4, 380, 60

3, 4, 380, 60

3, 4, 380, 60

-

Heat Pump

Heat Pump

Heat Pump

Heat Pump

Heat Pump

Heat Pump

HP

54

56

58

60

62

64

kW

151.2

156.8

162.4

168

173.6

179.2

515,900

535,000

554,100

573,200

592,300

611,500

134.5

138.4

144.8

151.2

156.2

161.2

458,900

472,200

494,100

515,900

533,000

550,000

Btu/h kW Btu/h kW Btu/h

Cooling

169.3

175.6

181.7

187.8

193.9

200

577,700

599,200

620,000

640,800

661,600

682,400

37.22

38.34

39.77

41.2

42.7

44.2

46.93

47.8

50.35

52.9

55.25

57.6

Heating

37.33

38.46

39.88

41.3

42.85

44.4

Cooling

67.1

68.2

70.2

72.2

74.5

76.8

Cooling 46°C

Cooling 46°C

kW

A

Heating

82.1

82.6

87

91.4

94.5

97.6

73

73.6

76.2

78.8

83.2

87.6 175.5

A

147.8

153.4

164.8

A

150

150

150

175

Nominal Cooling

-

4.06

4.07

4.05

Nominal Heating

-

4.54

4.57

4.56

4.55

4.53

4.5

Type

-

Propeller Fan / BLDC

Propeller Fan / BLDC

Propeller Fan / BLDC

Propeller Fan / BLDC

Propeller Fan / BLDC

Propeller Fan / BLDC 1100

Air Flow Rate

4.09

4.08

4.08

CMM

1010

1050

1070

1090

1095

mmAq

8

8

8

8

8

8

Liquid Pipe

Ɏ, mm

19.05

19.05

19.05

19.05

22.23

22.23

Gas Pipe

Ɏ, mm

41.28

41.28

41.28

41.28

53.98

53.98

Oil Equalizing Pipe

Ɏ, mm

6.35

6.35

6.35

6.35

6.35

6.35

Max. Length

m

200

200

200

200

200

200

Max. Height

m

110 (40)*

110 (40)*

110 (40)*

110 (40)*

110 (40)*

110 (40)*

Max.

Power cable

mm2

-

-

-

-

-

-

Communication cable

mm2

0.75~1.5

0.75~1.5

0.75~1.5

0.75~1.5

0.75~1.5

0.75~1.5

Type Factory Charging Sound Pressure

kg

R410A

R410A

R410A

R410A

R410A

R410A

(5.0) x 1 + (7.0) x 3

(7.0) x 4

(7.0) x 4

(7.0) x 4

(7.0) x 4

(7.0) x 4 (326) x 4

dB(A)

Net Weight

kg

(231) x 1 + (285) x 1 + (326) x 2

(285) x 2 + (326) x 2

(285) x 2 + (326) x 2

(285) x 1 + (326) x 2

(285) x 1 + (326) x 3

Shipping Weight

kg

(248) x 1 + (305) x 1 + (346) x 2

(305) x 2 + (346) x 2

(305) x 2 + (346) x 2

(305) x 1 + (346) x 2

(305) x 1 + (346) x 3

(346) x 4

Net Dimensions (WxHxD)

mm

(880 x 1695 x 765) x 1 + (1295 x 1695 x 765) x 3

(1295 x 1695 x 765) x 4

(1295 x 1695 x 765) x 4

(1295 x 1695 x 765) x 4

(1295 x 1695 x 765) x 4

(1295 x 1695 x 765) x 4

Shipping Dimensions (WxHxD)

(1363 x 1857 x 832) x 4

mm

(948 x 1857 x 832) x 1 + (1363 x 1857 x 832) x 3

(1363 x 1857 x 832) x 4

(1363 x 1857 x 832) x 4

(1363 x 1857 x 832) x 4

(1363 x 1857 x 832) x 4

Cooling

°C

-5 ~ 54

-5 ~ 54

-5 ~ 54

-5 ~ 54

-5 ~ 54

-5 ~ 54

Heating

°C

-20 ~ 24

-20 ~ 24

-20 ~ 24

-20 ~ 24

-20 ~ 24

-20 ~ 24

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * The maximum height of installation limitation for piping connections is only allowable when using PDM kits.

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

External Dimension

445,600

83

82

Refrigerant

130.6

436,800

MFA

Installation Limitation Field Wiring

Btu/h

MCA

External Static Pressure

Piping Connections

496,800

128

Heating

Cooling 46°C

Sound Pressure

Operating Temp. Range

477,700

kW

Cooling

Factory Charging

External Dimension

145.6

kW

Type

Sound

140

36.1

Installation Limitation

Refrigerant

52

kW

Btu/h

Air Flow Rate

Field Wiring

50

46.06

External Static Pressure

Piping Connections

Heat Pump

HP

34.25

Current Input (Nominal)

COP

Heat Pump

44.33

Power Input (Nominal)

O

3, 4, 380, 60

-

Btu/h

Cooling 46°C Heating

Power

RD520HQXHA

3, 4, 380, 60

System

System

HP

RD500HQXHA

Ɏ, #, V, Hz


Specification - Indoor Units System

System

4Way Cassette S S-Plasma ion (Optional) Motion Detect Sensor (Optional) Individual Blade Control

Wide High

Wide Blade

High Lift -UP

NO! Dust

Model Power Supply

ND0564HXCC

ND0714HXCC

ND0834HXCC

1, 2, 220, 60

1, 2, 220, 60

1, 2, 220, 60

1, 2, 220, 60

-

HP

HP

HP

HP

kW

4.5

5.6

7.1

8.3

15,400

19,100

24,200

Mode

Performance

Power

Capacity (Nominal)

kW Btu/h

Cooling

Power Input (Nominal)

W

Heating Cooling

Current Input (Nominal)

A

Heating

Min. / Std. / Max.

Liquid Pipe Piping Connections

Gas Pipe Drain Pipe

Field Wiring Refrigerant Sound

32

45

32

45

50 50

0.15

0.15

0.21

0.25

0.15

0.21

0.25

Turbo Fan / BLDC

Turbo Fan / BLDC

CMM

14.5

15.0

17.0

19.5

mmAq

-

-

-

-

Pa

-

-

-

9.52

Ɏ, mm

6.35

6.35

9.52

Ɏ, inch

1/4

1/4

3/8

3/8

Ɏ, mm

12.7

12.7

15.88

15.88

Ɏ, inch

1/2

1/2

5/8

5/8

Ɏ, mm

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

Power Source Wire

mm2

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

mm2

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

Type

-

R410A

R410A

R410A

R410A

Control Method

-

EEV

EEV

EEV

EEV

dBA

34/29

34/30

36/30

39

kg

15.5

15.5

15.5

15.5

Sound Pressure

High / Low

Shipping Weight

kg

Net Dimensions (W×H×D)

mm

Shipping Dimensions (W×H×D)

mm -

19.5

19.5

19.5

19.5

840 x 204 x 840

840 x 204 x 840

840 x 204 x 840

840 x 204 x 840

910 x 226 x 910

910 x 226 x 910

910 x 226 x 910

910 x 226 x 910

PC4NUSKA / PC4NBSKA / PC4NUSKE

PC4NUSKA / PC4NBSKA / PC4NUSKE

PC4NUSKA / PC4NBSKA / PC4NUSKE

PC4NUSKA / PC4NBSKA / PC4NUSKE 5.9

Panel Net Weight

kg

5.9

5.9

5.9

Shipping Weight

kg

8.4

8.4

8.4

8.4

mm

950 x 45 x 950

950 x 45 x 950

950 x 45 x 950

950 x 45 x 950

mm

1005 x 100 x 1005

Net Dimensions (W×H×D) Shipping Dimensions (W×H×D) Additional Accessories

32 32

Turbo Fan / BLDC

Panel Model Panel Size

9.3

Transmission Cable

Net Weight Dimensions

8.0 27,300

W

High

External Static Pressure

6.3 21,500

0.15

-

Output

Air Flow Rate

5.0 17,100

Turbo Fan / BLDC

Type

Motor Fan

Btu/h

Heating

Sub Duct

ND0454HXCC Ɏ, #, V, Hz

Cooling

Fresh Air

Drain Pump

1005 x 100 x 1005

1005 x 100 x 1005

1005 x 100 x 1005

-

Built-in

Built-in

Built-in

Built-in

mm / liter/h

750 / 24

750 / 24

750 / 24

750 / 24

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

Drain Pump Max. Lifting Height / Displacement

Air Filter

-

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.

85

84 Individual Controllers

Panel

MWR-WE10

MWR-WH0*

MWR-SH00

MR-DH00

PC4NUSKA

PC4NBSKA

PC4NUSKE

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Optional Accessories


Specification - Indoor Units System

System

4Way Cassette S S-Plasma ion (Optional) Motion Detect Sensor (Optional) Individual Blade Control

Wide High

Wide Blade

High Lift -UP

NO! Dust

Model Power Supply

ND1124HXEA

ND1284HXEA

ND1404HXEA

1, 2, 220, 60

1, 2, 220, 60

1, 2, 220, 60

1, 2, 220, 60

-

HP

HP

HP

HP

kW

9.0

11.2

12.8

14.0

30,700

38,200

43,700

47,800

10.0

12.5

13.8

16.0

34,100

42,700

47,100

54,600 89

Mode

Performance

Power

Capacity (Nominal)

kW Btu/h

Cooling

Power Input (Nominal)

W

Heating Cooling

Current Input (Nominal)

A

Heating

Min. / Std. / Max.

Liquid Pipe Piping Connections

Gas Pipe Drain Pipe

Field Wiring Refrigerant Sound

Dimensions

89

0.30

0.36

0.36

0.45

0.36

0.36

0.45

Turbo Fan / BLDC

Turbo Fan / BLDC

CMM

19.5

26.0

28.0

30.0

mmAq

-

-

-

-

Pa

-

-

-

9.52

Ɏ, mm

9.52

9.52

9.52

Ɏ, inch

3/8

3/8

3/8

3/8

Ɏ, mm

15.88

15.88

15.88

15.88

Ɏ, inch

5/8

5/8

5/8

5/8

Ɏ, mm

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

Power Source Wire

mm2

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

Transmission Cable

mm2

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5 R410A

Type

-

R410A

R410A

R410A

Control Method

-

EEV

EEV

EEV

EEV

dBA

39/32

39/32

41/35

45/38

Net Weight

kg

15.5

17.0

18.7

18.7

Shipping Weight

kg

19.5

22.0

24.0

24.0 840 x 288 x 840

Sound Pressure

High / Low

Net Dimensions (W×H×D)

mm

840 x 204 x 840

840 x 246 x 840

840 x 288 x 840

Shipping Dimensions (W×H×D)

mm

910 x 226 x 910

910 x 268 x 910

910 x 310 x 910

910 x 310 x 910

PC4NUSKA / PC4NBSKA / PC4NUSKE

PC4NUSKA / PC4NBSKA / PC4NUSKE

PC4NUSKA / PC4NBSKA / PC4NUSKE

PC4NUSKA / PC4NBSKA / PC4NUSKE 5.9

-

Panel Net Weight

kg

5.9

5.9

5.9

Shipping Weight

kg

8.4

8.4

8.4

8.4

mm

950 x 45 x 950

950 x 45 x 950

950 x 45 x 950

950 x 45 x 950

mm

1005 x 100 x 1005

Net Dimensions (W×H×D) Shipping Dimensions (W×H×D) Additional Accessories

73

Turbo Fan / BLDC

Panel Model Panel Size

73

78

W

High

External Static Pressure

78

0.30

-

Output

Air Flow Rate

62 62

Turbo Fan / BLDC

Type

Motor Fan

Btu/h

Heating

Sub Duct

ND0904HXEA Ɏ, #, V, Hz

Cooling

Fresh Air

Drain Pump

1005 x 100 x 1005

1005 x 100 x 1005

1005 x 100 x 1005

-

Built-in

Built-in

Built-in

Built-in

mm / liter/h

750 / 24

750 / 24

750 / 24

750 / 24

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

Drain Pump Max. Lifting Height / Displacement

Air Filter

-

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.

87

86 Individual Controllers

Panel

MWR-WE10

MWR-WH0*

MWR-SH00

MR-DH00

PC4NUSKA

PC4NBSKA

PC4NUSKE

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Optional Accessories


Specification - Indoor Units System

System

Slim 1Way Cassette Slim and Compact Design Quiet Operation No Overflowing Drain Water

Wide

High

Wide Blade

High Lift -UP

NO! Dust

Model Ɏ #, V, Hz

Power Supply Mode

Capacity (Nominal)

Power

Btu/h kW

Heating

Power Input (Nominal)

Cooling

Current Input (Nominal)

Cooling

Btu/h W

Heating

A

Heating Type

Motor Fan

kW

Cooling

-

Output

W

Air Flow Rate

High / Mid / Low

External Static Pressure

Min. / Std. / Max.

Liquid Pipe Piping Connections

Gas Pipe Drain Pipe

Field Wiring Refrigerant Sound

Dimensions

CMM

ND0361HXCC

1, 2, 220, 60

1, 2, 220, 60

HP / HR

HP / HR

HP / HR

2.2

2.8

3.6

7,500

9,600

12,300

2.5

3.2

4.0

8,500

10,900

13,600

40

45

50

40

45

50

0.20

0.23

0.25

0.20

0.23

0.25

%TQUUƀQY (CP 554

%TQUUƀQY (CP 554

%TQUUƀQY (CP 554

23

23

23

6/5/4

7/6/5

8/7/6

-

-

-

Pa

-

-

6.35

Ɏ, mm

6.35

6.35

Ɏ, inch

1/4

1/4

1/4

Ɏ, mm

12.7

12.7

12.7

Ɏ, inch

1/2

1/2

1/2

Ɏ, mm

VP20 (OD 25,ID 20)

VP20 (OD 25,ID 20)

VP20 (OD 25,ID 20)

Power Source Wire

mm2

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

Transmission Cable Type

mm2

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

-

R410A

R410A

R410A

-

EEV

EEV

EEV

30 / 25

30 / 25

32 / 27

Control Method Sound Pressure

High / Low

dBA

Net Weight

kg

10.5

10.5

10.5

Shipping Weight

kg

13.5

13.5

13.5

Net Dimensions (W×H×D)

mm

970 x 135 x 410

970 x 135 x 410

970 x 135 x 410

Shipping Dimensions (W×H×D)

mm

1164 x 212 x 478

1164 x 212 x 478

1164 x 212 x 478

PSSMA

PSSMA

PSSMA

Panel Net Weight

kg

-

3.0

3.0

3.0

Shipping Weight

kg

5.0

5.0

5.0

mm

1180 x 25 x 460

1180 x 25 x 460

1180 x 25 x 460

mm

1259 x 144 x 539

Net Dimensions (W×H×D) Shipping Dimensions (W×H×D) Additional Accessories

ND0281HXCC

1, 2, 220, 60

mmAq

Panel Model Panel Size

ND0221HXCC

Drain Pump

1259 x 144 x 539

1259 x 144 x 539

-

Built-in

Built-in

Built-in

mm / liter/h

750 / 24

750 / 24

750 / 24

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

Drain Pump Max. Lifting Height / Displacement

Air Filter

-

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.

89

88 Individual Controllers

Panel

MWR-WE10

MWR-WH0*

MWR-SH00

MR-DH00

PSSMA

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Optional Accessories


Specification - Indoor Units HSP Duct

Standard Formula for Easy Installation Twin Cross Flow Fan Small Size, Big Performance

High External Static Pressure Strong and Large Coverage Area Silent Operation with the Static Pressure Control Easy to Maintain

High

High

High Lift -UP

Anti-virus Filter

Fresh Air

Model Power Supply

Ɏ, #, V, Hz

Mode

-

Power

Btu/h kW

Heating

Power Input (Nominal)

Cooling

Current Input (Nominal)

Cooling

Btu/h W

Heating

A

Heating Type

Motor Fan

kW

Cooling

Capacity (Nominal)

-

Output

W

Air Flow Rate

High / Mid / Low

External Static Pressure

Min. / Std. / Max.

Liquid Pipe Piping Connections

Gas Pipe Drain Pipe

Field Wiring Refrigerant Sound

Dimensions

Additional Accessories

ND0712HXCC

1, 2, 220, 60

1, 2, 220, 60

HP / HR

HP / HR

5.6

7.1

19,100

24,200

6.3

8.0

21,500

27,300

70

75

70

75

%TQUUƀQY (CP 554

%TQUUƀQY (CP 554

14

14 15 / 14 / 13

mmAq

-

-

Pa

-

-

Ɏ, mm

6.35

9.52

Ɏ, inch

1/4

3/8

Ɏ, mm

12.7

15.88

Piping Connections

1/2

5/8

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 26)

1.5 / 2.5

1.5 / 2.5

mm2

0.75 / 1.5

0.75 / 1.5

Type

-

R410A

R410A

Control Method

-

EEV

EEV

36 / 28

38 / 28

dBA

Net Weight

kg

20.3

22.0

Shipping Weight

kg

25.0

26.0

Refrigerant Sound

mm

890 x 230 x 575

890 x 230 x 575

Shipping Dimensions (W×H×D)

mm

1077 x 299 x 642

1077 x 299 x 642

P2SMA

P2SMA

Panel Net Weight

kg

4.0

4.0

Shipping Weight

kg

8.0

8.0

Cooling

Current Input (Nominal)

Cooling

Dimensions

W

Heating

A

Heating

ND280HHXCC

1, 2, 220, 60

1, 2, 220, 60

HP / HR

HP / HR

22.4

28.0

25.0

31.5

530

790

530

790

3.80

5.90

3.80

5.90

Sirroco Fan / SSR

Sirroco Fan / SSR

CMM

58 / 52 / 47

72 / 65 / 58

mmAq

5 / 15 / 25

5 / 15 / 25 9.52

Type

-

Output

W

Air Flow Rate

High / Mid / Low

External Static Pressure

Min. / Std. / Max.

Gas Pipe

Pa Ɏ, mm

9.52

Ɏ, inch

3/8

3/8

Ɏ, mm

19.05

22.23

Ɏ, inch

3/4

7/8

Ɏ, mm

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

Power Source Wire

mm2

1.5 / 2.5

1.5 / 2.5

Transmission Cable

mm2

0.75 / 1.5

0.75 / 1.5 R410A

Type

-

R410A

Control Method

-

EEV

EEV

47 / 44

48 / 45

Sound Pressure

High / Low

dBA

Net Weight

kg

95.0

95.0

Shipping Weight

kg

105.0

105.0

Net Dimensions (W×H×D)

mm

1240 x 470 x 1040

1240 x 470 x 1040

Shipping Dimensions (W×H×D)

mm

1507 x 558 x 1155

1507 x 558 x 1155

-

-

-

Panel Net Weight

kg

-

-

Shipping Weight

kg

-

-

Panel Model Panel Size

ND220HHXCC

Btu/h

Drain Pipe Field Wiring

Net Dimensions (W×H×D)

-

kW

Heating

Power Input (Nominal)

Wired RC

Btu/h

Liquid Pipe

Ɏ, mm mm2

kW

Cooling

Motor Fan

Ɏ, inch

Transmission Cable

High / Low

Power

0.40

Smart Control

Capacity (Nominal)

0.40

High Lift -UP

Ɏ, #, V, Hz

Mode

0.38

14 / 13 / 12

Easy Filter

Model Power Supply

0.38

CMM

Panel Model Panel Size

ND0562HXCC

Power Source Wire

Sound Pressure

System

System

2Way Cassette

Net Dimensions (W×H×D)

mm

1030 x 25 x 650

1030 x 25 x 650

Net Dimensions (W×H×D)

mm

-

Shipping Dimensions (W×H×D)

mm

1103 x 151 x 727

1103 x 151 x 727

Shipping Dimensions (W×H×D)

mm

-

-

Built-in

Built-in

Optional / MDP-N047SNC1

Optional / MDP-N047SNC1

Drain Pump

Drain Pump

-

Max. Lifting Height / Displacement

mm / liter/h

Air Filter

-

750 / 24

750 / 24

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

Additional Accessories

Drain Pump

Drain Pump

-

Max. Lifting Height / Displacement

mm / liter/h

Air Filter

-

470 / 24

470 / 24

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.

Optional Accessories

Optional Accessories

91

90

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.

Panel

MWR-WE10

MWR-WH0*

MWR-SH00

MR-DH00

Individual Controllers

P2SMA

Drain Pump MWR-WE10

MWR-WH0*

MWR-SH00

MR-DH00

MRK-A00

MRW-10A

MDP-N047SNC1

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Individual Controllers


Specification - Indoor Units System

System

MSP Duct Narrow Width Strong and Large Coverage Area Silent Operation with the Static Pressure Control Easy to Maintain

High

Anti-virus Filter

Easy Filter

High Lift -UP

Smart Control

Wired RC

Model Ɏ, #, V, Hz

Power Supply Mode

Capacity (Nominal)

Power

Btu/h kW

Heating

Btu/h

Cooling

Power Input (Nominal)

W

Heating Cooling

Current Input (Nominal)

A

Heating Type

Motor Fan

kW

Cooling

-

Output

Air Flow Rate

High / Mid / Low

External Static Pressure

Min. / Std. / Max.

Liquid Pipe Piping Connections

Gas Pipe Drain Pipe

Field Wiring Refrigerant Sound

Dimensions

Additional Accessories

ND112SHXCC

ND128SHXCC

ND140SHXCC

1, 2, 220, 60

1, 2, 220, 60

1, 2, 220, 60

1, 2, 220, 60

HP / HR

HP / HR

HP / HR

HP / HR

10.0

11.2

12.8

14.0

34,100

38,200

43,700

47,800

11.0

12.5

13.8

16.0

37,500

42,700

47,100

54,600

260

275

370

430

260

275

370

430

1.52

1.57

2.26

2.45

1.52

1.57

2.26

2.45

Sirroco Fan / SSR

Sirroco Fan / SSR

Sirroco Fan / SSR

Sirroco Fan / SSR

W

130

130

218

218

CMM

25.0

27 / 25 / 23

32 / 30 / 28

37 / 34 / 31

mmAq

4 / 8 / 10

6 / 8 / 10

6 / 8 / 10

6 / 8 / 10 9.52

Pa Ɏ, mm

9.52

9.52

9.52

Ɏ, inch

3/8

3/8

3/8

3/8

Ɏ, mm

15.88

15.88

15.88

15.88

Ɏ, inch

5/8

5/8

5/8

5/8

Ɏ, mm

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

Power Source Wire

mm2

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

Transmission Cable Type

mm2

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

-

R410A

R410A

R410A

R410A

-

EEV

EEV

EEV

EEV

39 / 35

39 / 35

39 / 35

43 / 38

Control Method Sound Pressure

High / Low

dBA

Net Weight

kg

35.0

36.0

52.0

52.0

Shipping Weight

kg

41.0

42.0

59.0

59.0

Net Dimensions (W×H×D)

mm

1150 x 320 x 480

1150 x 320 x 480

1200 x 360 x 650

1200 x 360 x 650

Shipping Dimensions (W×H×D)

mm

1396 x 424 x 584

1396 x 424 x 584

1480 x 420 x 790

1480 x 420 x 790

-

-

-

-

-

Panel Net Weight

kg

-

-

-

-

Shipping Weight

kg

-

-

-

-

Panel Model Panel Size

ND100SHXCC

Net Dimensions (W×H×D)

mm

-

-

-

-

Shipping Dimensions (W×H×D)

mm

-

-

-

-

Optional / MDP-M075SGU1

Optional / MDP-M075SGU1

Optional / MDP-M075SGU2

Optional / MDP-M075SGU2

750 / 24

750 / 24

750 / 24

750 / 24

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

Drain Pump

Drain Pump

-

Max. Lifting Height / Displacement

mm / liter/h

Air Filter

-

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.

93

92 Individual Controllers

Drain Pump MWR-WE10

MWR-WH0*

MWR-SH00

MR-DH00

MRK-A00

MRW-10A

MDP-M075SGU1 MDP-M075SGU2

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Optional Accessories


Specification - Indoor Units System

System

Slim Duct Flexible Installation Easier Drain Pump Installation Slim Design Easy to Maintain

High

Anti-virus Filter

Easy Filter

High Lift -UP

Smart Control

Model Ɏ, #, V, Hz

Power Supply Mode

Capacity (Nominal)

Power

Btu/h kW

Heating

Btu/h

Cooling

Power Input (Nominal)

Heating

Current Input (Nominal)

Heating

W

Cooling

A

Type

Motor Fan

kW

Cooling

-

Output High / Mid / Low

External Static Pressure

Min. / Std. / Max.

Gas Pipe Drain Pipe

Field Wiring Refrigerant Sound

Dimensions

ND036LHXCC

ND045LHXCC

ND056LHXCC

1, 2, 220, 60

1, 2, 220, 60

1, 2, 220, 60

1, 2, 220, 60

HP / HR

HP / HR

HP / HR

HP / HR

HP / HR

2.2

2.8

3.6

4.5

5.6

7,500

9,600

12,300

15,400

19,100

2.5

3.2

4.0

5.0

6.3

8,500

10,900

13,600

17,100

21,500

47

60

75

110

120

47

60

75

110

120 0.67

0.32

0.34

0.35

0.65

0.32

0.34

0.35

0.65

0.67

Sirroco Fan / SSR

Sirroco Fan / SSR

Sirroco Fan / SSR

Sirroco Fan / SSR

Sirroco Fan / SSR 15.5 / 14 / 12.5

CMM

8/7/6

9/8/7

10 / 8.5 / 7

14.5 / 13 / 11.5

mmAq

0/2/4

0/2/4

0/2/4

0/2/4

0/2/6

0 / 19.6 / 39.2

0 / 19.6 / 39.2

0 / 19.6 / 39.2

0 / 19.6 / 39.2

0 / 19.6 / 39.2 6.35

Pa Ɏ, mm

6.35

6.35

6.35

6.35

Ɏ, inch

1/4

1/4

1/4

1/4

1/4

Ɏ, mm

12.7

12.7

12.7

12.7

12.7

Ɏ, inch

1/2

1/2

1/2

1/2

1/2

Ɏ, mm

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

mm2

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

Transmission Cable Type

mm2

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

-

R410A

R410A

R410A

R410A

R410A

-

EEV

EEV

EEV

EEV

EEV

31 / 26

32 / 27

32 / 27

33 / 30

33 / 30

Control Method Sound Pressure

High / Low

dBA

Net Weight

kg

26.0

26.0

26.0

32.0

32.0

Shipping Weight

kg

29.5

29.5

29.5

36.5

36.5

Net Dimensions (W×H×D)

mm

900 x 199 x 600

900 x 199 x 600

900 x 199 x 600

1100 x 199 x 600

1100 x 199 x 600

Shipping Dimensions (W×H×D)

mm

1150 x 270 x 710

1150 x 270 x 710

1150 x 270 x 710

1350 x 270 x 710

1350 x 270 x 710

Panel Model Shipping Weight Net Dimensions (W×H×D) Shipping Dimensions (W×H×D) Additional Accessories

ND028LHXCC

1, 2, 220, 60

Power Source Wire

Panel Net Weight Panel Size

ND022LHXCC

W

Air Flow Rate

Liquid Pipe Piping Connections

Wired RC

Drain Pump

-

-

-

-

-

-

kg

-

-

-

-

-

kg

-

-

-

-

-

mm

-

-

-

-

-

mm Drain Pump

-

Max. Lifting Height / Displacement

-

-

-

-

-

Optional / MDP-E075SEE3

Optional / MDP-E075SEE3

Optional / MDP-E075SEE3

Optional / MDP-E075SEE3

Optional / MDP-E075SEE3

mm / liter/h

Air Filter

-

750 / 24

750 / 24

750 / 24

750 / 24

750 / 24

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.

95

94 Individual Controllers

Drain Pump

MWR-WE10

MWR-WH0*

MWR-SH00

MR-DH00

MRK-A00

MRW-10A

MDP-E075SEE3

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Optional Accessories


Specification - Indoor Units System

System

Slim Duct Flexible Installation Easier Drain Pump Installation Slim Design Easy to Maintain

High

Anti-virus Filter

Easy Filter

High Lift -UP

Smart Control

Model Ɏ, #, V, Hz

Power Supply Mode

Capacity (Nominal)

Power

Btu/h kW

Heating

Btu/h

Cooling

Power Input (Nominal)

W

Heating Cooling

Current Input (Nominal)

Refrigerant Sound

Dimensions

ND140LHXCC

1, 2, 220, 60

1, 2, 220, 60

HP / HR

HP / HR

HP / HR

HP / HR

HP / HR

7.1

9.0

11.2

12.8

14.0

24,200

30,700

38,200

43,700

47,800

8.0

10.0

12.5

13.8

16.0

27,300

34,100

42,700

47,100

54,600

130

170

170

200

220

130

170

170

200

220 1.24

0.96

1.13

0.96

1.13

1.24

Sirroco Fan / SSR

Sirroco Fan / BLDC

Sirroco Fan / BLDC

Sirroco Fan / BLDC

Sirroco Fan / BLDC

CMM

17.0 / 15 / 13.5

29 / 27 / 25

31.2 / 29 / 27

34 / 32 / 30

36 / 34 / 32

mmAq

0/2/6

0/3/6

0/3/6

0/3/6

0/3/6

0 / 19.6 / 39.2

0 / 29.4 / 58.8

0 / 29.4 / 58.8

0 / 29.4 / 58.8

0 / 29.4 / 58.8 9.52

Output

W

Air Flow Rate

High / Mid / Low

External Static Pressure

Min. / Std. / Max.

Gas Pipe

Pa Ɏ, mm

9.52

9.52

9.52

9.52

Ɏ, inch

3/8

3/8

3/8

3/8

3/8

Ɏ, mm

15.88

15.88

15.88

15.88

15.88

Ɏ, inch

5/8

5/8

5/8

5/8

5/8

Ɏ, mm

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

Power Source Wire

mm2

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

Transmission Cable Type

mm2

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

-

R410A

R410A

R410A

R410A

R410A

-

EEV

EEV

EEV

EEV

EEV

36 / 32

40 / 36

40 / 36

41 / 38

41 / 38

Control Method Sound Pressure

High / Low

dBA

Net Weight

kg

32.0

44.0

44.0

44.0

44.0

Shipping Weight

kg

36.5

50.0

50.0

50.0

50.0

Net Dimensions (W×H×D)

mm

1100 x 199 x 600

1300 x 295 x 690

1300 x 295 x 690

1300 x 295 x 690

1300 x 295 x 690

Shipping Dimensions (W×H×D)

mm

1350 x 270 x 710

1575 x 370 x 835

1575 x 370 x 835

1575 x 370 x 835

1575 x 370 x 835

-

-

-

-

-

-

kg

-

-

-

-

-

Panel Net Weight Shipping Weight Net Dimensions (W×H×D) Shipping Dimensions (W×H×D) Additional Accessories

ND128LHXCC

1, 2, 220, 60

0.96

Panel Model Panel Size

ND112LHXCC

1, 2, 220, 60

0.96

-

Drain Pipe Field Wiring

ND090LHXCC

1, 2, 220, 60

0.70

Type

Liquid Pipe Piping Connections

ND071LHXCC

0.70

A

Heating

Motor Fan

kW

Cooling

Wired RC

Drain Pump

kg

-

-

-

-

-

mm

-

-

-

-

-

mm Drain Pump

-

Max. Lifting Height / Displacement

-

-

-

-

-

Optional / MDP-E075SEE3

Optional / MDP-E075SEE3

Optional / MDP-E075SEE3

Optional / MDP-E075SEE3

Optional / MDP-E075SEE3

mm / liter/h

Air Filter

-

750 / 24

750 / 24

750 / 24

750 / 24

750 / 24

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.

97

96 Individual Controllers

Drain Pump

MWR-WE10

MWR-WH0*

MWR-SH00

MR-DH00

MRK-A00

MRW-10A

MDP-E075SEE3

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Optional Accessories


Specification - Indoor Units System

System

Fresh Air Intake Duct Flexible Installation Highly Efficient BLDC Motor Quiet Operation Flexible Static Pressure Control

High

Anti-virus Filter

Easy Filter

High Lift -UP

Smart Control

Wired RC

Model Ɏ, #, V, Hz

Power Supply Mode

Capacity (Nominal)

Power

Btu/h

Cooling

A

Heating Type

-

Output

Air Flow Rate

High / Mid / Low

External Static Pressure

Min. / Std. / Max.

Liquid Pipe Piping Connections

Gas Pipe Drain Pipe

Field Wiring Refrigerant Sound

Additional Accessories

HP / HR

14.0

22.4

28.0

13.9

17.4 370

220

300

220

300

370

1.60

2.20

3.00

1.60

2.20

3.00

Sirroco Fan / SSR

Sirroco Fan / SSR

Sirroco Fan / SSR

W

183

400

400

CMM

18.0

28.0

35.0

mmAq

10 / 20 / 25

10 / 23 / 25

10 / 25 / 28 9.52

Pa Ɏ, mm

9.52

9.52

Ɏ, inch

3/8

3/8

3/8

Ɏ, mm

15.88

19.05

22.23

Ɏ, inch

5/8

3/4

7/8

Ɏ, mm

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

VP25 (OD 32,ID 25)

mm2

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

Transmission Cable Type

mm2

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

-

R410A

R410A

R410A

-

EEV

EEV

EEV

42

46

47

60.0

93.0

95.0

Control Method Sound Pressure

High / Low

dBA kg

Shipping Weight

70.0

103.0

105.0

Net Dimensions (W×H×D)

mm

kg

1100 x 390 x 650

1240 x 470 x 1040

1240 x 470 x 1040

Shipping Dimensions (W×H×D)

mm

1335 x 512 x 829

1507 x 558 x 1155

1507 x 558 x 1155

-

-

-

-

Panel Net Weight

kg

-

-

-

Shipping Weight

kg

-

-

-

Net Dimensions (W×H×D)

mm

-

-

-

Shipping Dimensions (W×H×D)

mm

-

-

-

Optional / MDP-N047SNC0

Optional / MDP-N047SNC1

Optional / MDP-N047SNC1

Panel Model Panel Size

HP / HR

Power Source Wire

Net Weight Dimensions

1, 2, 220, 60

HP / HR

8.9

W

Heating

Current Input (Nominal)

ND280EHXCC

1, 2, 220, 60

Btu/h

Cooling

Power Input (Nominal)

ND220EHXCC

1, 2, 220, 60

47,800

kW

Heating

Motor Fan

kW

Cooling

ND140EHXCC

Drain Pump

Drain Pump

-

Max. Lifting Height / Displacement

mm / liter/h

Air Filter

-

750 / 24

470 / 24

470 / 24

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.

99

98 Individual Controllers

Drain Pump

MWR-WE10

MWR-WH0*

MWR-SH00

MR-DH00

MRK-A00

MRW-10A

MDP-N047SNC0 MDP-N047SNC1

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Optional Accessories


Specification - Indoor Units System

System

Neo Forte Clean-cut Front Pane Silver Accent Line Bottom Opening Front Pane

Model Power Supply

Ɏ, #, V, Hz

Mode

Capacity (Nominal)

Power

Btu/h kW

Heating

Btu/h

Cooling

Power Input (Nominal)

W

Heating Cooling

Current Input (Nominal)

A

Heating Type

Motor Fan

kW

Cooling

-

Output

W

Air Flow Rate

High / Mid / Low

External Static Pressure

Min. / Std. / Max.

Liquid Pipe Piping Connections

Gas Pipe Drain Pipe

Field Wiring Refrigerant Sound

Dimensions

CMM

ND036NHXCC

ND056NHXCC

ND071NHXCC

1, 2, 220, 60

1, 2, 220, 60

1, 2, 220, 60

1, 2, 220, 60

HP / HR

HP / HR

HP / HR

HP / HR

HP / HR

2.2

2.8

3.6

5.6

6.8

7,500

9,600

12,300

19,100

23,200

2.5

3.2

4.0

6.3

7.0

8,500

10,900

13,600

21,500

23,900 50

25

25

30

45

25

25

30

45

50

0.16

0.16

0.18

0.27

0.30

0.16

0.16

0.18

0.27

0.30

%TQUUƀQY (CP 554

%TQUUƀQY (CP 554

%TQUUƀQY (CP 554

%TQUUƀQY (CP 554

%TQUUƀQY (CP 554

23

23

23

40

40

7.8 / 6.8 / 5.8

8.2 / 7.2 / 6.2

9.3 / 8.3 / 7.3

12 / 10.5 / 9

14 / 12.5 / 11

-

-

-

-

-

Pa

-

-

-

-

9.52

Ɏ, mm

6.35

6.35

6.35

6.35

Ɏ, inch

1/4

1/4

1/4

1/4

3/8

Ɏ, mm

12.7

12.7

12.7

12.7

15.88

Ɏ, inch

1/2

1/2

1/2

1/2

5/8

Ɏ, mm

VP18 (OD19 ,ID16)

VP18 (OD19 ,ID16)

VP18 (OD19 ,ID16)

VP18 (OD19 ,ID16)

VP18 (OD19 ,ID16)

Power Source Wire

mm2

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

Transmission Cable

mm2

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

Type

-

R410A

R410A

R410A

R410A

R410A

Control Method

-

EEV (External)

EEV (External)

EEV (External)

EEV (External)

EEV (External) 41 / 30

32 / 23

34 / 23

36 / 23

40 / 30

Net Weight

Sound Pressure

High / Low

dBA kg

9.0

9.0

9.0

13.0

13.0

Shipping Weight

kg

11.0

11.0

11.0

16.0

16.0

Net Dimensions (W×H×D)

mm

825 x 285 x 189

825 x 285 x 189

825 x 285 x 189

1099 x 315 x 217

1099 x 315 x 217

Shipping Dimensions (W×H×D)

mm

900 x 349 x 252

900 x 349 x 252

900 x 349 x 252

1137 x 377 x 299

1137 x 377 x 299

-

-

-

-

-

-

kg

-

-

-

-

-

Panel Model Shipping Weight Net Dimensions (W×H×D) Shipping Dimensions (W×H×D) Additional Accessories

ND028NHXCC

1, 2, 220, 60

mmAq

Panel Net Weight Panel Size

ND022NHXCC

Drain Pump

kg

-

-

-

-

-

mm

-

-

-

-

-

mm

-

-

-

-

-

-

-

-

-

-

-

Drain Pump Max. Lifting Height / Displacement

mm / liter/h

Air Filter

-

-

-

-

-

-

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.

101

100 Standard Accessories

Individual Controllers

Individual Controllers MWR-WE10

MWR-WH0*

MWR-SH00

MR-DH00

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Optional Accessories


Specification - Indoor Units System

System

Neo Forte - E Clean-cut Front Pane Silver Accent Line Bottom Opening Front Pane Internal EEV

Model Power Supply

Ɏ, #, V, Hz

Mode

Capacity (Nominal)

Power

Btu/h kW

Heating

Power Input (Nominal)

Cooling

Current Input (Nominal)

Cooling

Btu/h W

Heating

A

Heating Type

Motor Fan

kW

Cooling

-

Output

W

Air Flow Rate

High / Mid / Low

External Static Pressure

Min. / Std. / Max.

Piping Connections

Gas Pipe Drain Pipe

Field Wiring Refrigerant Sound

Dimensions

Additional Accessories

ND036QHXCC

ND056QHXCC

ND071QHXCC

1, 2, 220, 60

1, 2, 220, 60

1, 2, 220, 60

1, 2, 220, 60

HP / HR

HP / HR

HP / HR

HP / HR

HP / HR

2.2

2.8

3.6

5.6

6.8

7,500

9,600

12,300

19,100

23,200

2.5

3.2

4.0

6.3

7.0

8,500

10,900

13,600

21,500

23,900 50

25

25

30

45

25

25

30

45

50

0.16

0.16

0.18

0.27

0.30

0.16

0.16

0.18

0.27

0.30

%TQUUƀQY (CP 554

%TQUUƀQY (CP 554

%TQUUƀQY (CP 554

%TQUUƀQY (CP 554

%TQUUƀQY (CP 554

23

23

23

40

40

7.8 / 6.8 / 5.8

8.2 / 7.2 / 6.2

9.3 / 8.3 / 7.3

12 / 10.5 / 9

14 / 12.5 / 11

mmAq

-

-

-

-

-

Pa

-

-

-

-

-

6.35

6.35

6.35

6.35

9.52

Ɏ, inch

1/4

1/4

1/4

1/4

3/8

Ɏ, mm

12.7

12.7

12.7

12.7

15.88

Ɏ, inch

1/2

1/2

1/2

1/2

5/8

Ɏ, mm

VP18 (OD19 ,ID16)

VP18 (OD19 ,ID16)

VP18 (OD19 ,ID16)

VP18 (OD19 ,ID16)

VP18 (OD19 ,ID16)

Power Source Wire

mm2

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

Transmission Cable

mm2

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5

0.75 / 1.5 R410A

Type

-

R410A

R410A

R410A

R410A

Control Method

-

EEV

EEV

EEV

EEV

EEV

35 / 26

35 / 26

39 / 26

42 / 33

44 / 33

Sound Pressure

High / Low

dBA

Net Weight

kg

9.0

9.0

9.0

13.0

13.0

Shipping Weight

kg

11.0

11.0

11.0

16.0

16.0

Net Dimensions (W×H×D)

mm

825 x 285 x 189

825 x 285 x 189

825 x 285 x 189

1065 x 298 x 218

1065 x 298 x 218

Shipping Dimensions (W×H×D)

mm

900 x 349 x 252

900 x 349 x 252

900 x 349 x 252

1137 x 377 x 299

1137 x 377 x 299

Panel Model Panel Size

ND028QHXCC

1, 2, 220, 60

CMM

Ɏ, mm

Liquid Pipe

ND022QHXCC

-

-

-

-

-

-

Panel Net Weight

kg

-

-

-

-

-

Shipping Weight

kg

-

-

-

-

-

Net Dimensions (W×H×D)

mm

-

-

-

-

-

Shipping Dimensions (W×H×D)

mm

-

-

-

-

-

-

-

-

-

-

-

mm / liter/h

-

-

-

-

-

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

Drain Pump

Drain Pump Max. Lifting Height / Displacement

Air Filter

-

103

102

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * The concept of Neo Forte(EEV included) is commercial application only.

Standard Accessories

Individual Controllers

Individual Controllers MWR-WE10

MWR-WH0*

MWR-SH00

MR-DH00

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Optional Accessories


Control System

System

CLASSIFICATION

Ceiling

PRODUCT

Controller Integrated Management System

2Way Installation Compact but Powerful

Interface Module

Interior Design

Anti-virus Filter

Ɏ, #, V, Hz

Mode

Capacity (Nominal)

Power

Btu/h kW

Heating

Power Input (Nominal)

Cooling

Current Input (Nominal)

Cooling

Btu/h W

Heating

A

Heating Type

Motor Fan

kW

Cooling

-

Output

W

Air Flow Rate

High / Mid / Low

External Static Pressure

Min. / Std. / Max.

Liquid Pipe Piping Connections

Gas Pipe Drain Pipe

Field Wiring Refrigerant Sound

ND056CHXCC

ND071CHXCC

1, 2, 220, 60

1, 2, 220, 60

HP / HR

HP / HR

5.6

7.1

19,100

24,200

6.3

8.0

21,500

27,300

72

80

72

80

0.33

0.35

0.33

0.35

Sirroco Fan / AC

Sirroco Fan / AC

47

47

CMM

14 / 13 / 12

18 / 16.5 / 15

-

-

Pa

-

-

Ɏ, mm

6.35

9.52

Ɏ, inch

1/4

3/8 15.88

Ɏ, mm

12.7

Ɏ, inch

1/2

5/8

Ɏ, mm

VP18 (OD19 ,ID16)

VP18 (OD19 ,ID16)

mm2

1.5 / 2.5

1.5 / 2.5

mm2

0.75 / 1.5

0.75 / 1.5

Type

-

R410A

R410A

Control Method

-

EEV (External)

EEV (External)

38 / 32

41 / 36

21.0

21.0

High / Low

dBA kg

Shipping Weight

26.0

26.0

Net Dimensions (W×H×D)

mm

kg

1000 x 650 x 200

1000 x 650 x 200

Shipping Dimensions (W×H×D)

mm

1080 x 730 x 300

1080 x 730 x 300

Panel Net Weight

Additional Accessories

Centralized Control System

mmAq

Panel Model Panel Size

Wireless RC

Flexible

Transmission Cable

Net Weight Dimensions

Light Weight

Power Source Wire

Sound Pressure

Shipping Weight

-

-

-

kg

-

-

kg

-

-

Net Dimensions (W×H×D)

mm

-

-

Shipping Dimensions (W×H×D)

mm

-

-

Drain Pump

Drain Pump Max. Lifting Height / Displacement

APPLICATION MODEL DVM Desert

S-NET 3

MST-P3P

DVM Desert

S-NET Mini

MST-S3W

DVM Desert

MIM-B16

DVM Desert

MCM-B102

DVM Desert

MCM-A100

DVM Desert

Centralized Controller

MCM-A202D

DVM Desert

7 Day Scheduler

MWR-BS00

Centralized Controller

Operation Mode Selection Switch

MCM-C200

DVM Desert

MIM-B13D

DVM Desert

MIM-B13E

DVM Desert

PIM

Controller

Model Power Supply

IMAGE

MIM-D00A

Function Controller

Good Design

MODEL

DMS 2

Control System & Accessories

Specification - Indoor Units

-

-

-

mm / liter/h

-

-

.QPI NKHG ſNVGT

.QPI NKHG ſNVGT

Air Filter

-

System Controller

Interface Module

Individual Control System

Building Management System

Guest Room Management System

Converter

Controller

Centralized Control Interface Module

Wired Remote Controller

MWR-WE10

Cassette, Wall-mounted, Ceiling, Duct

Wired Remote Controller

MWR-WH00

Cassette, Wall-mounted, Ceiling, Duct

5KORNKſGF 9KTGF 4GOQVG %QPVTQNNGT

MWR-SH00

Cassette, Wall-mounted, Ceiling, Duct

Wireless Remote Controller

MR-DH00

Cassette, Wall-mounted, Ceiling, Duct (Receiver Needed)

Wireless Signal Receiver

MRK-A00

Duct (For Wireless Remote Controller)

Wireless Signal Receiver Wire

MRW-10A

Duct (For Wireless Remote Controller)

External Room Sensor

MRW-TA

Cassette, Wall-mounted, Ceiling, Duct

LonWorks Interface Module

MIM-B07

DVM Desert

LonWorks Gateway

MIM-B18

DVM Desert

BACnet Gateway

MIM-B17

DVM Desert

KEY-TAG Interface Module

MIM-B02

DVM Desert

External Contact Interface Module

MIM-B14

DVM Desert

Converter Unit

MIM-C02

DVM Desert

* Product specifications in the publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.

105

104 Individual Controllers

MWR-WE10

MWR-WH0*

MWR-SH00

MR-DH00

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner

Optional Accessories


%NCUUKĹżECVKQP

Y- joint

Image

Model

Description

MXJ-YA1509K

15kW and below

MXJ-YA2512K

Over 15.0 ~ 40.6kW and below

MXJ-YA2812K

Over 40.6 ~ 46.4 kW and below

MXJ-YA2815K

Over 46.4 ~ 69.6 kW and below

MXJ-YA3119K

Over 69.6 ~ 98.6 kW and below

MXJ-YA3819K

Over 98.6 ~ 139.2 kW and below

MXJ-YA4422K

Over 139.2 kW

MXJ-T3819K

Below 48 HP

MXJ-T4422K

Over 50 HP

MXJ-HA3819K

Over 69.7 kW

MXJ-HA3115K

Below 69.6 kW

MXJ-HA2512K

Below 46.4 kW

MXD-A13K116A

Below 3.6 kW (1 Room) + 5.6 kW ~9.0 kW (1Room)

Outdoor Joint (Outdoor Connection)

Header Joint

Relevant Unit

Below 3.6 kW (2 Rooms)

MXD-A16K200A

5.6 kW~9.0 kW (2Rooms)

MXD-A22K200A

Over 9.0 kW (2Rooms)

MXD-A13K216A

Below 3.6 kW (2 Rooms) + 5.6 kW ~ 9.0 kW (1Room)

MXD-A13K300A

Below 3.6 kW (3 Rooms)

MXD-A16K213A

Below 3.6 kW (1 Room) + 5.6 kW ~ 9.0 kW (2Rooms)

MXD-A16K300A

5.6 kW ~ 9.0 kW (3Rooms)

MEV-A13SA

Below 3.6 kW (1 Room)

MEV-A16SA

5.6 kW ~ 9.0 kW (1Room)

MDP-E075SEE3

Slim Duct (2.0 ~ 14.0 kW)

MDP-M075SGU1

MSP Duct (9.0 / 11.2 kW)

MDP-M075SGU2

MSP Duct (12.8 / 14.0 kW)

MDP-N047SNC0

Fresh Air Intake Duct (14.0 kW)

MDP-N047SNC1

HSP Duct (22.4 / 28.0 kW), Fresh Air Intake Duct (22.4 / 28.0 kW)

%NCUUKĹżECVKQP

PDM Kits (High Elevation Kits)

DVM Desert

Requisite

AHU Kits

DVM Desert

MXD-A13K200A

Remark

DVM Desert

Image

Model

Description

MXD-A38K2A

DVM Desert (8~12HP)

MXD-A12K2A

DVM Desert (14~16HP)

MXD-A58K2A

DVM Desert (18~20HP)

MXD-A16K1X025A

7.0 ~ 8.75 kW AHU

MXD-A22K1X050A

14.0 ~ 17.5 kW AHU

MXD-A22K2X075A

21.0 ~ 26.25 kW AHU

MXD-A22K2X100A

28.0 ~ 35.0 kW AHU

PC4NUSKA

9C[ %CUUGVVG 5 9CHĆ€G

PC4NBSKA

4Way Cassette S - Black

PC4NUSKE

4Way Cassette S - Classic

PSSMA

Slim 1Way Cassette

P2SMA

2Way Cassette

MSD-CAN1

4Way Cassette S

Relevant Unit

Remark

-

Option

-

Option

Not compatible with conventional 4Way Cassette

Requisite

-

Requisite

Control System & Accessories

Control System & Accessories

Accessories

Requisite

Option

Wall-mounted & Ceiling indoor unit (For 2 indoor units)

Option

Wall-mounted & Ceiling indoor unit (For 3 indoor units)

Option

Wall-mounted & Ceiling indoor unit (For single unit)

Option

-

Option

Front Panel

S-Plasma ion

Option

EEV Kits

Drain Pump

106

107

2012 SAMSUNG System Air Conditioner

2012 SAMSUNG System Air Conditioner


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.