The implant with impermeable fitting that optimizes bacterial sealing and the health of periimplant tissue.
COMPONENTS INDICATION TABLE
Ø
2.5
mm
Im
pla n
t
Ø3
.0 m
ØI
mp lan t
26
m
Internal Thread Ø 1.8
Ø
Internal Thread Ø 1.8
MORSE TAPER MORSE TAPER
3.5, 3.75, 4.0, 4.3 and 5.0 mm MORSE TAPER WS ZYGOMATIC CM
4.0, 5.0 and 6.0 mm
Screw-retained Prosthesis •CM Abutment (single) •CM Mini Abutment (multiple) •CM Angled Mini Abutment 17° and 30° (multiple) •CM Micro Abutment (multiple)
•WS Abutment (single) •Ws Mini Abutment (multiple) •CM Transepithelial Abutment (multiple)
Cemented Prosthesis •CM Angled Universal Post 17° and 30° •CM Universal Post Through Screw •CM Universal Post (single body) •Anatomical Post in Titanium
•WS Universal Post with Through Screw
Overdenture •CM Mini Ball Attachment
Protocol •CM Micro Abutment •CM Mini Abutment •CM Angled Mini Conical Abutment 17° and 30° •Cylinder and Distal Bar Passive Fitting Technique •Castable Cylinder – Mini Abutment •Titanium Cylinder – Mini Abutment •Brass Cylinder – Mini Abutment
•WS Mini Abutment (single) Passive Fitting Technique •Castable Cylinder – Mini Abutment •Titanium Cylinder – Mini Abutment •Brass Cylinder – Mini Abutment
M orse
Ta p e r
• GAP reduced (impermeable fitting); • • • • •
Stable Anti-rotational fixing; High mechanical strength; Unique prosthetic interface, independent of the implant diameter; First system with Morse Taper fitting in Brazil; The CM angle and the internal thickness of the implant enable the design of the screw thread to reach the cervical portion of the implant; • High resistance, comparable to implants with external hex with regular platform; •NeoPoros Surface.
Simplified installation with no mount.
Morse Taper Implants now with indexer.
Each point at Installation Driver corresponds to one plane face of the indexer.
New line of Exact components, specific for CM Index Implants.
27
CM Implants now with Prosthetic Index
The hexagonal prosthetic index simplifies the implant installation process, reduces surgical time, increases the resistance to insertion torque and allows dentists to install the prosthesis already with a forecast for the positioning of the crown regarding the implant, thus providing even more safety, speed and flexibility to clinical and laboratorial works.
Capture and Transport of the Implant Specific drivers to the hexagonal prosthetic indexer in the implant, available for contraangle or ratchet, allow the capture of the implants directly on the package. The replacement of old mounts for these drivers guarantees greater resistance to torque, more faster and safety on procedures.
Drivers The installation drivers have six markings which match with the six faces of the hexagonal prosthetic index of implant. At the installation moment, one of these markings in driver should be in vestibular position, facilitating thus the posterior prosthetic procedure.
28
CM Exact Line
Apart from the single CM interface for all implant diameters, the CM implants now have one more family of prosthetic components, the EXACT LINE. This line features have at their tip a hex index that allows positioning the prosthesis over the implant (prosthetic indexing), making our Morse Tapers line even more flexible.
Conventional components or Exact
Only Conventional Components
Versatility of Index Implant The CM implants with prosthetic index remain compatible with the entire line of CM prosthetic components that you already know. However, the Exact line is only compatible with CM implants with Index.
Contact one of our consultants and discover the advantages of the new Morse Taper implants and whole family of Exact prosthetic components.
CM Index Implants
CM Implant
29
h c u n a L
Product Characteristics: •Morse Taper interface; •NeoPoros Surface; •Implant with conical central nucleus; •Cervical conicity to reduce the compressive tension; •Double and progressive threads; •Cutting chambers in counterclockwise direction; •Apical thread with blade shape; •The installation is performed with specific drivers to the index of the implant, providing the implant capture directly on packaging, offering more safety and speed; •Suitable for bones type III and IV and pos-extracting installation; •Unique prosthetic interface for all implant diameters; •Best prosthetic resolution with CM Implant 2mm infraosseous; •Perforation rotation: 500-800 rpm; •Insertion rotation: 30 rpm.
3.5 mm 4.3 mm 5.0 mm
30
Alvim Drill 5.0
Alvim Drill 4.3
Alvim Drill 3.5
Alvim Drill 2.0
Initial Drill
Drill sequence
Morse
8.0 mm
10.0 mm
11.5 mm
13.0 mm
16.0 mm
109.692
109.682
109.693
109.683
109.684
109.689
109.688
109.627
109.628
109.629
109.690
109.685
109.691
109.686
109.687
Taper
Ø 3.5
Ø 4.3
Ø 5.0
CM Cover Screw 2 mm
•Use Digital Driver 1.2mm (104.007) for installation;
117.013
•Do not exceed torque of 10 N.cm.
117.017
Healings 0.8 mm
1.5 mm
2.5 mm
3.5 mm
4.5 mm
5.5 mm
Ø 3.3
106.182
106.168
106.169
106.170
106.183
106.184
Ø 4.5
106.175
106.171
106.172
106.173
106.174
106.180
•Use Digital Driver 1.2mm (104.007) for installation; •Do not exceed torque of 10 N.cm.
31
Product Characteristics: •Cylindrical implant with Morse Taper interface; •NeoPoros Surface; •The installation is performed with specific drivers to the index of the implant, providing the implant capture directly on packaging, offering more safety and speed; •Double thread (faster installation and less trauma); •High cutting capacity; •Suitable for bones type I and II and grafting areas in block; •Cover screw not included; •Unique prosthetic interface for all implant diameters; •Cervical diameter equal to implant diameter; •Observe the specific Pilot Drill (countersink function); •Better prosthetic resolution with CM Implant inserted 2mm infraosseous; •Perforation rotation: 800-1200 rpm; •Insertion rotation: 30 rpm.
CM Pilot 4.3/5.0
Titamax Drill 4.3
Titamax Drill 3.8
CM Pilot 3.3/4.0
CM Pilot 3/3.75
Titamax Drill 3.3
CM Pilot 2.8/3.5
Titamax Drill 3.15
Titamax Drill 3.0
Titamax Drill 2.8
Pilot 2/3
Titamax Drill 2.0
Initial Drill
Drill sequence
3.5 mm 3.75 mm 4.0 mm 5.0 mm Optional
32
Morse
7.0 mm
8.0 mm
9.0 mm
11.0 mm
13.0 mm
15.0 mm
Taper
17.0 mm
Ø 3.5
109.613
109.614
109.615
109.616
109.617
109.618
109.619
109.606
109.607
109.608
109.609
109.610
109.611
109.612
109.630
109.631
109.632
109.633
109.620
109.634
109.635
109.642
109.643
109.644
109.645
109.646
Ø 3.75
Ø 4.0
Ø 5.0
CM Cover Screw 2 mm
•Use Digital Driver 1.2mm (104.007) for installation; •Do not exceed torque of 10 N.cm.
117.013
117.017
Healings 0.8 mm
1.5 mm
2.5 mm
3.5 mm
4.5 mm
5.5 mm
Ø 3.3
106.182
106.168
106.169
106.170
106.183
106.184
Ø 4.5
106.175
106.171
106.172
106.173
106.174
106.180
•Use Digital Driver 1.2mm (104.007) for installation; •Do not exceed torque of 10 N.cm.
33
Morse Taper
Product Characteristics: •Cylindrical implant with Morse Taper interface; •NeoPoros Surface; •The installation is performed with specific drivers to the index of the implant, providing the implant capture directly on packaging, offering more safety and speed; •Double thread (faster installation and less trauma); •High compaction capacity (bone expansion); •Suitable for bones type III and IV and in areas with little bone thickness; •Cover screw not included; •Unique prosthetic interface for all implant diameters; •Cervical diameter equal to implant diameter; •Simplified instrumentation in the prepare of surgical alveolus; •Best prosthetic resolution with CM Implant 2mm infraosseous; •Perforation rotation: 800-1200 rpm; •Insertion rotation: 30 rpm.
Titamax Drill 3.0
Titamax Drill 2.8
Pilot 2/3
Titamax Drill 2.0
Initial Drill
Drill sequence
3.5 mm 3.75 mm 4.0 mm Optional
34
Morse
9.0 mm
11.0 mm
13.0 mm
109.661
109.662
109.663
109.664
109.665
109.666
109.667
109.668
109.669
109.670
109.636
109.637
109.638
109.639
109.640
Taper
15.0 mm 17.0 mm
Ø 3.5
Ø 3.75
Ø 4.0
CM Cover Screw •Use Digital Driver 1.2mm (104.007) for 2 mm
installation; •Do not exceed torque of 10 N.cm.
117.013
117.017
Healings 0.8 mm
1.5 mm
2.5 mm
3.5 mm
4.5 mm
5.5 mm
Ø 3.3
106.182
106.168
106.169
106.170
106.183
106.184
Ø 4.5
106.175
106.171
106.172
106.173
106.174
106.180
•Use Digital Driver 1.2mm (104.007) for installation; •Do not exceed torque of 10 N.cm.
35
Product Characteristics: • Conical implant with Morse Taper interface; • NeoPoros Surface; • The installation is performed with specific drivers to the index of the implant, providing the implant capture directly on packaging, offering more safety and speed; • Double thread (faster installation and less trauma); • Suitable for bones type III and IV and pos-extracting installation; • Cover screw not included; • Cervical diameter equal to implant diameter; • Unique prosthetic interface for all implant diameters; • Observe the specific Pilot Drill (function countersink); • Best prosthetic resolution with CM Implant 2mm infraosseous; • Perforation rotation: 500-800 rpm; • Insertion rotation: 30 rpm.
3.5 mm 4.3 mm 5.0 mm
36
CM Pilot 4.3/5.0
Alvim Drill 5.0
CM Pilot 3.6/4.3
Alvim Drill 4.3
CM Pilot 2.8/3.5
Alvim Drill 3.5
Alvim Drill 2.0
Initial Drill
Drill Sequence
Morse
10.0 mm
11.5 mm
13.0 mm
109.657
109.658
109.659
109.621
109.660
109.647
109.648
109.649
109.622
109.651
109.652
109.653
109.654
109.655
109.656
8.0 mm
Taper
16.0 mm
Ø 3.5
Ø 4.3
Ø 5.0
CM Cover Screw 2 mm
•Use Digital Driver 1.2mm (104.007) for installation; •Do not exceed torque of 10 N.cm.
117.013
117.017
Healings 0.8 mm
1.5 mm
2.5 mm
3.5 mm
4.5 mm
5.5 mm
Ø 3.3
106.182
106.168
106.169
106.170
106.183
106.184
Ø 4.5
106.175
106.171
106.172
106.173
106.174
106.180
•Use Digital Driver 1.2mm (104.007) for installation; •Do not exceed torque of 10 N.cm.
37
Morse Taper
Medullar and Cortical
Product Characteristics: •Cylindrical implant with Morse Taper interface; •NeoPoros Surface; •Pre-mounted; •Cover screw not included; •Optimization of primary stability; •Excellent alternative to posterior edentulous lower jaw; •Specific Surgical Kit; •Observe the specific Pilot Drill (same function of countersink drill); •In Medullar Titamax WS Implant, the pilot drill is optional; •Perforation rotation: 200-300 rpm; •Insertion rotation: 30 rpm; •Unique Morse Taper prosthetic interface (same dimensions as CM Zygomatic Implants).
CM Pilot 5.3/6.0
Titamax Drill 5.3
CM Pilot 4.3/5.3
CM Pilot 4.3/5.0
Titamax Drill 4.3
CM Pilot 3.8/4.3
Titamax Drill 3.8
CM Pilot 3.3/4.0
CM Pilot 3/3.75
Titamax Drill 3.3
CM Pilot 2.8/3.5
Titamax Drill 3.0
Titamax Drill 2.8
Pilot 2/3
Titamax Drill 2.0
Initial Drill
Drill sequence
4.0 mm 5.0 mm 6.0 mm Obligatory for Cortical Implant and Optional for CM Medullar Implant
38
Morse
Cortical 5.0 mm
Taper
Medullar 6.0 mm
Ø 4.0
5.0 mm
6.0 mm
109.578
109.579
109.580
109.581
Ø 5.0 109.604
109.605
Ø 5.0
Ø 6.0
109.574
109.575
109.576
109.577
Ø 6.0
•Use Digital Driver 1.2mm (104.007)
WS Cover Screw
for installation; •Do not exceed torque of 10 N.cm.
117.016
WS Healings 0.8 mm
1.5 mm
2.5 mm
3.5 mm
106.186
106.187
106.188
106.189
•Use Digital Driver 1.2mm (104.007) for installation; •Do not exceed torque of 10 N.cm.
39
Demonstrative sequence of
CM Abutment and WS Abutment
Prosthetic Torque Ratchet Driver
Titanium
CoCr
Castabl e
Torque Connection 1.2
GT Cylinder
GT Protective Cylinder
GT Analogue
Transfer GT Open Tra y Transfer
•Same prosthetic sequence as the GT Implant;
Transfer GT Closed Tra y Transfer
Prosthetic Torque Ratchet Driver
•Available in Titanium; •Minimum interocclusal space of 5.0mm from the mucosa level; •Conicity 15°; •Single screw-retained prosthesis (anti-rotational); •The cylinders come with Neotorque screw, except the castables, that comes with Titanium screw.
Torque Connection 1.6
32
N.cm CM Abutment
40
WS Abutment
Morse
CM Abutment
WS Abutment
0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm 115.162
115.147
115.148
Taper
115.152
115.163
115.164
0.8 mm 1.5 mm 2.5 mm 3.5 mm 115.180
115.181
115.182
115.183
• Observe corresponding sequence and indicated torque; • Use Torque Connection 1.6mm (105.006); • To torque control, use Prosthetic Torque Ratchet Driver (104.026).
GT Transfer Open Tra y
GT Cylinder
Closed Tra y
108.039
108.040
•Available in Titanium; •For transference and molding of prosthesis; •For open tray or closed tray technique; •Anti-rotational.
GT Analogue 101.037
Castabl e
118.180
Titanium
118.179
CoCr
118.242
•Available: Titanium: for provisional prosthesis; CoCr: overcastting; Castable: casting. •With screw; •To screw torque, use Torque Connection 1.2mm (105.005); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026); •Anti-rotational.
•Available in Titanium; •Replica of implant platform or prosthetic component; •For prosthesis construction or prosthetic planning.
GT Protective Cylinder
GT Cylinder Screw
106.102
•Available in Titanium; •Used to protect the component during the prosthesis construction; •To installation, use Digital Driver 1.2mm (104.007).
Titanium
Neotorque
116.038
116.228
•Observe indicated torque; •Use Torque Connection 1.2mm (105.005); •To torque control, use Prosthetic Torque Ratchet Driver (104.026). Neotorque
•Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in preload increase.
41
Demonstrative sequence
CM Mini Abutment and WS CM Angled Mini Abutment Prosthetic Torque Ratchet Driver
Titanium
Castabl e
Nobl e / CoCr
Torque Connection 1.2
Cylinder of Mini Conical Abutment
Protective Cylinder of Mini Conical Abutment
Analogue Mini Conical Abutment
Transfer Mini Conical Abutment Multifuncional
Transfer Mini Conical Abutment
Prosthetic Torque Ratchet Driver
•Available in Titanium; •Minimum interocclusal space of 4.4mm from the mucosa level; •Multiple and screw-retained prosthesis; •Conicality 20°; •The cylinders come with Neotorque screw, except the castables, that comes with Titanium screw.
Prosthetic Abutment Driver
32
N.cm
WS Mini Conical Abutment
42
Prosthetic Torque Abutment Driver Connection 0.9mm
32
N.cm
CM Mini Conical Abutment
15
N.cm
CM Angl ed Mini Conical Abutment and EXACT (17 0 and 30 0 )
Morse
Taper
CM Mini Conical Abutment 0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm 115.154
115.149
115.150
115.151
115.153
115.160
CM Angled Mini Conical Abutment 1.5 mm 2.5 mm 3.5 mm
WS Mini Conical Abutment
115.177
115.178
115.166
115.167
115.168
300
115.169
115.170
115.171
• Height of CM angled prosthetic components available on page 54; • To component torque, use Torque Connection 0.9 (105.065).
0.8 mm 1.5 mm 2.5 mm 3.5 mm 115.176
170
115.179
•Observe sequence and indicated torque; •To component torque, use Prosthetic Abutment Driver (105.009); •To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Cylinder Mini Conical Abutment
Transfer of Mini Conical Abutment Open Tra y
Closed Tra y
Multifunctional
Ø 4.1
108.022
108.021
108.068
Short Screw
116.036
•Available in Titanium; •Component with molding function by prosthesis construction; •For open tray or closed tray technique; •Rotational.
Ø 4.1
Castabl e
Titanium
Nobl e
CoCr
CoCr for welding
118.112
118.113
118.206
118.209
118.210
•Available in: Titanium: provisional prosthesis; CoCr: overcastting; Castable: casting; Gold: gold alloy with high melting range. •With screw; •To screw torque, use Torque Connection 1.2mm (105.005) •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026); •Rotational for screw-retained multiple elements.
Analogue of Mini Conical Abutment Ø 4.1
101.020
•Available in Titanium; •Replica of prosthetic component; •For prosthesis construction or prosthetic planning.
Protective Cylinder of Mini Conical Abutment Ø 4.1
Cylinder Screw
Ø 4.1
Titanium
Neotorque
116.037
116.227
•Observe indicated torque; •Use Torque Connection 1.2mm (105.005); •To torque control, use Prosthetic Torque Ratchet Driver (104.026).
106.054
•Available in Titanium; •Used to protect the component during the prosthesis construction; •To installation, use Digital Driver 1.2mm (104.007).
Neotorque •Application of a thin pellicle with
carbon basis, which promotes low friction coefficient, resulting in preload increase.
43
Demonstrative sequence of
CM Micro Abutment Prosthetic Torque Ratchet Driver
Titanium
CoCr
Castabl e
Torque Connection 1.2
Cylinder of Micro Abutment
Protective Cylinder of Micro Abutment
3.5 Analogue of Micro Abutment
Transfer CM Micro Abutment Open tra y
Prosthetic Torque Ratchet Driver
•Available in Titanium; •Multiple and screw-retained prosthesis; •Indicated to CM Implants with diameter of 3.5mm and close to each other; •Minimum interocclusal space of 4.4mm from the
Prosthetic Abutment Driver
mucosa level; •Prosthetic fitting diameter of 3.3mm ;
32
•The cylinders come with Neotorque screw, except
N.cm
the castables, that comes with Titanium screw. CM Micro Abutment
44
Morse
Protective Cylinder of CM Micro Abutment
CM Micro Abutment 1.5 mm 2.5 mm 3.5 mm 115.200
115.201
Taper
115.202
•Observe sequence and indicated torque; •To component torque, use Prosthetic Abutment Driver (105.009); •To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Transfer of CM Micro Abutment Rotational
106.199
•Available in Titanium; •Used to protect the component during the prosthesis construction; •To installation, use Digital Driver 1.2mm (104.007).
Cylinder of CM Micro Abutment Titanium
118.246
Castabl e
CoCr
118.245
118.247
108.070
•Available in Titanium; •Component with molding function by prosthesis construction; •For open tray technique; •Rotational.
•Available in: Titanium: provisional prosthesis; CoCr: overcastting; Castable: casting. •With screw; •To screw torque, use Torque Connection 1.2mm (105.005); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026); •Rotational for screw-retained multiple elements.
Analogue of CM Micro Abutment 101.057
Cylinder Screw
•Available in Titanium; •Replica of prosthetic component; •For prosthesis construction or prosthetic planning.
Titanium
Neotorque
116.037
116.227
•Observe indicated torque; •Use Torque Connection 1.2mm (105.005); •To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Neotorque
•Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in preload increase.
45
Demonstrative sequence of
CM and Exact Anatomic Post
Indicated sequence
Optional sequence Prosthesis conclusion
15
N.cm
Prosthetic Torque Ratchet Driver
Laboratorial Phase
Conventional molding
Torque Connection 0.9mm
Customization if is necessary
maximum CM Anatomic Post
Prosthetic Torque Ratchet Driver
Laboratorial Phase
CM Implant Analogue Torque Connection 0,9mm
•Available in Titanium; •Cemented unitary prosthesis; •Possible customization; •Indicated for aesthetic area; •Height of anatomic prosthetic components available on page 55.
46
15
N.cm CM Anatomic Post Transfer of CM Exact Implant Closed tray
Transfer of CM Exact Implant Closed tray
Transfer of CM Exact Implant Open tray
Morse
Taper
Lateral Exact CM Anatomic Post
Exact CM Anatomic Post 1.5 mm 2.5 mm 3.5 mm
1.5 mm 2.5 mm 3.5 mm
114.422 114.423 114.424
114.425 114.426 114.427
•Available in Titanium; •Cemented prosthesis; •To installation, use Torque Connection 0,9mm (105.065); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026); •Exact component exclusive for CM Index implants.
Lateral CM Anatomic Post
CM Anatomic Post 1.5 mm 2.5 mm 3.5 mm
1.5 mm 2.5 mm 3.5 mm
114.328
114.419
114.329 114.330
114.420
114.421
•Available in Titanium; •Cemented prosthesis; •To installation, use Torque Connection 0,9mm (105.065); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026).
CM Implant Transfer
Conventional
Open tra y
Closed tra y
108.069
108.041
Short
108.065
Exact
108.076
CM Implant Analogue 101.058
•Available in Titanium; •Replica of the implant; •To the prosthesis confection or prosthetic planning.
•Available in Titanium; •Component with molding function for the prosthesis confection; •For open tray and closed tray technique; •Length: - Short: 15 mm; - Conventional: 20 mm.
47
Demonstrative sequence of
CM Universal Post
Cylinder of Universal Post
Ø 3.3
Ø 4.5
Analogue of CM Post
Ø 3.3
Ø 4.5
Transfer of CM Post
Prosthetic Torque Ratchet Driver
•Available in Titanium; •Cemented single prosthesis; •Straight component with single body.
Torque Connection 1.2 mm
32
N.cm
CM Universal Post
48
Castabl e
Alumina
Provisional
Ø 4.5 Castabl e
Provisional
Alumina
Ø 3.3
Morse
Taper
CM Universal Post
Ø 4.5 Ø 3.3 Ø 4.5
6 mm
Ø 3.3
4 mm
0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm 114.129
114.077 114.078 114.079
114.136
114.137
114.131
114.080 114.081
114.082
114.142
114.143
114.130
114.086 114.087 114.088
114.139
114.140
114.132
114.083
114.145
114.146
114.084 114.085
•To installation, use Torque Connection 1.2mm (105.005); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Ø 4.5
Ø 4.5
108.044
Ø 3.3
108.043
Ø 4.5
Ø 4.5
4 mm 6 mm
Ø 3.3
Castable
118.186
118.181
118.192
118.188
118.183
118.194
118.187
118.182
118.193
118.189
118.184
118.195
• Available in: Acrylic: provisional prosthesis; Alumina: for “metal free” prosthesis; Castable: casting. • Compatible with all Universal Posts, if not prepared.
Universal Post Analogue
Universal Post Set
Ø 4.5
Provisional
Alumina
108.045
•Available in polymer; •Component with molding function by prosthesis construction; •For closed tray technique; •Select transfer according to the component to be molded, as prosthetic planning; •Anti-rotational.
Ø 3.3
6 mm
108.042
108.060 108.062 108.061 108.063
•Components Kit of Universal Post line, containing Transfer and Provisional / Castable Cylinders.
Ø 3.3 Ø 4.5 Ø 3.3 Ø 4.5
4 mm
Ø 3.3
Ø 3.3
6 mm
Ø 4.5
6 mm
Ø 3.3
4 mm
Universal Post Transfer
4 mm
Universal Post Cylinder
101.038 101.040 101.039 101.041
• Available in Titanium; • Replica of prosthetic component platform; • For prosthesis construction and prosthetic planning.
49
Demonstrative sequence of
CM Universal Post Through Screw Exact CM Universal Post WS Universal Post
15
N.cm
Prosthesis concluded
Prosthesis concluded
Prosthetic Torque Ratchet Driver
Torque Connection 0.9mm
Torque Connection 1.2mm
maximum CM Universal Post Through Screw
Exact CM Universal Post
WS Post
Laboratorial Ph ase
Laboratorial Ph ase
CM Implant
WS Implant
Analogue
Analogue
•Available in Titanium; •Cemented single prosthesis; •Indicated for laboratorial customization.
Transfer of Exact CM Implant Closed tra y
50
CM Implant Transfer Closed tra y
CM Implant Transfer Open tra y
WS Implant Transfer Closed tra y
32
N.cm
Morse
Taper
Exact CM Universal Post
Ø 4.5 Ø 3.3 Ø 4.5
6 mm
Ø 3.3
4 mm
0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm 114.408 114.360
114.361
114.362
114.363 114.364
114.357 114.358
114.359
114.372
114.409 114.366 114.367
114.368
114.369 114.370
114.342
114.375
114.410
114.411
114.340
114.341
114.373
114.376
•Component with through screw; •To installation, use Torque Connection 0.9mm (105.065); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026); •Component Exact exclusive for CM Implant Index.
CM Universal Post Through Screw
WS Universal Post 0.8 mm 1.5 mm 2.5 mm 3.5 mm
Ø 4.5
114.115
114.149
114.150
114.151
114.152
114.153
114.117
114.118
114.119
114.162
114.163
114.155
114.156
114.157
114.158
114.159
114.160
114.116
114.120
114.121
114.122
114.165
114.166
•To installation, use Torque Connection 0.9mm (105.065); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026).
CM Implant Transfer
Conventional
Ø 4.5
4 mm
Ø 3.3
114.148
114.183
114.184
114.185
114.186
6 mm
Ø 4.5
6 mm
Ø 3.3
4 mm
0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm
114.187
114.188
114.189
114.190
•In two pieces (body and screw); •To installation, use Torque Connection 1.2mm (105.005); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Analogue
Open tra y
Closed tra y
CM
WS
108.069
108.041
101.058
101.055
Short
108.065
Exact
108.076
WS
108.064
•Available in Titanium; •Replica of prosthetic component platform; •For prosthesis construction and prosthetic planning.
•Available in Titanium; •Component with molding function for the prosthesis confection; •For open tray and closed tray technique; •Length: - Short: 15 mm; - Conventional: 20 mm
51
Demonstrative sequence of
Universal Post Angled CM and Exact
Universal Post Cylinder
Ø 3.3
Ø 4.5
CM Post Analogue
Ø 3.3
Ø 4.5
CM Post Transfer
Prosthetic Torque Ratchet Driver
•Available in Titanium; •Cemented single prosthesis.
Torque Connection 0.9mm
15
N.cm
Exact CM Angl ed Universal Post
52
CM Angl ed Universal Post
Castabl e
Alumina
Provisional
Ø 4.5 Castabl e
Provisional
Alumina
Ø 3.3
Morse
Exact CM Angled Universal Post
CM Angled Universal Post 1.5 mm 2.5 mm 3.5 mm
300
Ø 3.3 Ø 4.5
114.391
114.392
Ø 4.5 170
114.387 114.388 114.389
Ø 3.3
114.393 114.394 114.395
Ø 4.5
114.396
114.397
114.398
Ø 3.3
114.402
114.403
114.404
Ø 4.5 300
114.399
114.400
114.401
Ø 3.3
114.405
114.406
114.407
Ø 4.5
4 mm
114.390
Ø 3.3
6 mm
114.385 114.386
4 mm
Ø 4.5
114.384
6 mm
Ø 3.3
6 mm
Ø 4.5
4 mm
Ø 3.3
6 mm
Ø 4.5
170
4 mm
1.5 mm 2.5 mm 3.5 mm
Ø 3.3
Taper
114.089 114.090 114.091 114.095 114.096 114.097 114.092 114.093 114.094 114.098 114.099
114.100
114.101
114.102
114.103
114.107
114.108
114.109
114.104
114.105
114.106
114.110
114.111
114.112
•Component with through screw; •To installation, use Torque Connection 0.9mm (105.065); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026); •Height of CM angled prosthetic components available on page 54; •Exact component exclusive for CM Index implant.
Universal Post Cylinder
Ø 4.5
108.043
Ø 3.3 Ø 4.5
Ø 4.5
4 mm 6 mm
Ø 3.3
Castable
118.186
118.181
Provisional 118.192
118.188
118.183
118.194
118.187
118.182
118.193
118.189
118.184
118.195
•Available in: Acrylic: provisional prosthesis; Alumina: for “metal free” prosthesis; Castable: casting. •Compatible with all Universal Posts, if not prepared.
Universal Post Analogue
Universal Post Set
Ø 4.5
Alumina
108.045
•Available in polymer; •Component with molding fuction to the prosthesis confection; •For closed tray technique; •Select Transfer according to the component to be molded as prosthetic planning; •Anti-rotational.
Ø 3.3
4 mm
Ø 4.5
6 mm
108.044
108.060 108.062 108.061 108.063
•Components Kit of Universal Post line, containing Transfer and Provisional / Castable Cylinders.
Ø 3.3 Ø 4.5 Ø 3.3 Ø 4.5
4 mm
Ø 3.3
108.042
Ø 3.3
6 mm
Ø 4.5
6 mm
Ø 3.3
4 mm
Universal Post Transfer
101.038 101.040 101.039 101.041
•Available in Titanium; •Replica of prosthetic component platform; •For prosthesis construction and prosthetic planning.
53
54
5.90
170 5.80
3.50
4.80
2.50
3.80
1.50
5.20
3.50
4.20
2.50
4.90
3.50
3.90
2.50
2.90
1.50
4.50
3.50
3.50
2.50
Ă˜ 3.3
4.90 3.50
3.90 2.50
1.50
4.90
3.50
3.90
2.50
1.50
2.50
1.50
300 3.20
170
2.90
1.50
Height of CM Angled Prosthetic Components
Angled Universal Post Ă˜ 4.5
Angled Mini Conical Abutment
300
Height of Anatomic Post and Lateral Anatomic Post
CM Anatomic Post 5 mm
8 mm
Transmucosal
Transmucosal
6 mm
6 mm
CM Lateral Anatomic Post
Transmucosal
Transmucosal
6.5 mm
4.3 mm
5.3 mm
4.7 mm
55
Demonstrative sequence of
CM Mini Ball Attachment
O’ring with Cylinder
Disk
Straight
Positioner
Positioner
positioner
70
14 0
Prosthetic Torque Ratchet Driver
Protection Disk
Positioner
Prosthetic Abutment Driver
•Available in Titanium;
32
•Application of Nitride Titanium coating for increased the
N.cm
wear resistance; •Directly over the implant; •For Overdenture prosthesis, its function is the O’ring retention; •It’s recommended capture the components in patient’s mouth, one by one; •Obligatory to use positioner for capture; •O’ring with protection disc; •See the demonstrative sequence of Mini Ball Attachment on page 126. 56
CM Mini Ball Attachment
Morse
Castable Ball Attachment
CM Mini Ball Attachment 1.5 mm 2.5 mm 3.5 mm 4.5 mm 102.069 102.070 102.071
102.078
102.097
•Select according to the mucosa height; •To installation, use Prosthetic Abutment Driver (105.009); •To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Positioners straight, 70 and 140
Taper
102.076
•Available in polymer; •Indicated to define the correct distance between Attachment Ball components and O’ring with cylinder; •Corrects the parallelism between the implants; •Essential for O’ring capturing.
O’ring with Cylinder 102.073
•Available in Titanium (cylinder); •Available in polymer (O’ring); •Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention; •Protection disk included; •Not autoclavable.
Mini O’ring 102.075
•Available in polymer; •Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention; •Not Autoclavable.
•Casting in various metals; •May be cemented in natural roots or waxed in bars for overdenture retention.
Protection Disk 102.077
•Package with 10 units.
O’ring Remover 104.044
•Digital Driver with function of O’ring replacing to the cylinder.
O’ring Mount 104.043
•Digital Driver with function of O’ring replacing to the cylinder.
57