Products Mini Catalogue

Page 1

The Industry

02

Morse Taper Implants

10

Ti External Hex Implants

26

II Plus Internal Hex Implants

40

Zygomatic Implants

51

Surgical Instruments

54

Bone Grafting and Orthodontic Anchorage

57

1


The Industry In order to guarantee our innovative potential and our high technology, in 2009 we inaugurated our New Industrial Complex, featuring 12.000m2, occupying a plot of land measuring 50.000m2, expanding our production capacity like no other one in Latin America. The Complex is equipped with automated machinery, which runs during 3 non-stop shifts. Thanks to such manufacturing potential, Neodent is also the only Latin American company in its

QUALITY CONTROL

segment capable of manufacturing its instruments inhouse. The whole project was planned so as to optimize production and to allow our structure to irradiate our company’s fundamental values: advances in technology, respect for human beings and socio-environmental responsibility. CLEAN ROOM

INSTRUMENTS PRODUCTION

PACKAGE

2


Continuous Development and Quality Control

TRI-DIMENSIONAL CONTROL

ROBOTICS

Apart from counting on the best and most modern equipments, the Industrial Complex has an integrated Materials Laboratory (LIM), aimed directly at research, development and quality control. This Lab

MECHANICAL TESTS

provides: Scanning Electron Microscope (MEV), which guarantees quality starting from raw-materials and up to the finishing of the products; mechanic and metallographic tests that assess the long term mechanical endurance, and also allow the micro-structural analysis of all products. All of it results in excellence for you, our client who gives us your trust and who take our name into your consulting room.

PRODUCTION

SCANNING ELECTRON MICROSCOPE

3


Environment Starting with the selective garbage collection, up to the treatment of the residual waters at our Effluents Treatment Station, we perform continuous monitoring of environmental issues, observing the applicable environmental and sanitation regulations. When we conceived our new Industrial Complex, we have adopted social and environmental solutions that are efficient, respecting the needs of our associates, and reinforcing the image of the company as a reference icon in environmentally correct actions.

EFFLUENTS TREATMENT STATION

WATER RETURNED TO THE ENVIRONMENT AFTER TREATMENT

PREFERENCE FOR NATURAL LIGHTING

4


A globally renowned company, made 100% for you.

Besides our industrial and commercial headquarters located in Curitiba (PR – Brazil), we count with twelve branches, located in the cities of Sao Paulo, Bauru, Rio de Janeiro, Belo Horizonte, Porto Alegre, Goiania, Brasilia, Londrina, Recife and Vitoria. Also, eight authorized distributors extend our network into seven different Brazilian states (Amazonas, Bahia, Mato Grosso, Mato Grosso do Sul, Para, Santa Catarina and Tocantins), apart from our overseas branches located in Portugal and in the United States. Our international distribution network reaches thirteen other countries, namely Argentina, Bolivia, Chile, Colombia, Ecuador, Spain, Italy, Lebanon, Paraguay, Peru, Dominican Republic, Taiwan and Venezuela.

Contact Whenever you need, you can count on our different communication channels: www.neodent.com.br

5


Surface Following years of intense researches and development of new technologies, Neodent has achieved the most modern and current techniques for the surface treatment of implants: the Neoporos Surface. The NeoPoros surface is obtained from the concept of blasting with abrasive particles, which has automated controls for speed, direction, pressure and size of the particles that collide with the implant. With that, we create craters at the implant’s surface using oxides of controlled granularity. Next, the surface is leveled using the acid subtraction technique. Several scientific researches were performed, attesting the efficiency of the bio-contact quality between bone and implant, with the NeoPoros surface.

Continuous Evolution and Safety Assurance Electronic microscopes of the Neoporos Surface in amplifications of 2000X and 5000X.

Controlled roughness to guarantee the size of the pores between 2.5 and 5.0Âľm throughout the entire implant surface.

Direct contact of the bone to the implant, showing osteogenesis by contact and the osseous induction potential of Neoporos Surface.

Bone crest formed over a cervical portion of the Morse taper implants with Neoporos surface after a period of osseointegration.

6


We count on the scientific support of ILAPEO – The Latin American Institute of Research and Dental Education -, a center of excellence in research, advances and innovations in the clinical practice of dentistry. An institute made up of professionals, professors and researchers of the highest level of knowledge who offer post-graduate courses, such as specialization and master’s degree, recognized by CFO, MEC

MULTI-DISCIPLINARY LABORATORY

and CAPES. BLUE CLINIC

LIBRARY

AUDITORIUM

RECEPTION

7


IMPLANT INDICATION TABLE

Bone type I

Bone type II

Bone type III

Bone type IV

Morse Taper

Morse Taper

Morse Taper

MEDULLAR

Cortical with Mount

With Mount

In accordance with the bone classification of Lekholm and Zard (1985).

NEODENT IMPLANTS APEX

Drive Implant Apex

8

Cortical Implant Apex

EX Implant Apex

Alvim Implant Apex


CONNECTIONS AND TORQUES

0.9

1.2

1.6

Prosthetic Abutments

32N.cm

CM Abutment and WS 15N.cm

CM Angled Mini Abutment and Exact

MORSE TAPER

CM Mini Conical Abutment, WS and CM Micro Abutment

32N.cm

Universal Post CM and WS

32N.cm

Universal Post CM Through Screw

15N.cm

Universal Post CM and Angled Exact

15N.cm

Anatomic Post CM and Exact

15N.cm

Mini Ball Attachment

32N.cm 10N.cm

Cylinders

20N.cm

Conical Abutment (Ø 4.3) and Slim Fit (Ø 4.3) 20N.cm

Conical Abutment (Ø 5.0)

20N.cm

Mini Conical Abutment (Ø 3.3 and Ø 4.3) 20N.cm

EXTERNAL HEX

Mini Abutment Slim Fit (Ø 5.0)

32N.cm

Mini Abutment Slim Fit (Ø 4.1) Angled Mini Conical Abutment (Ø 4.1)

20N.cm

Universal Post SF, Personalizable and Angled

32N.cm

UCLA (Ø 3.3; Ø 4.1; Ø 4.3; Ø 5.0)

32N.cm

Mini Ball Attachment

32N.cm

Cylinders

10N.cm

INTERNAL HEX

Conical Abutment II Plus and Mini Abutment II Plus

20N.cm

Conical Abutment II Plus Angled

20N.cm

Universal Post and Angled II Plus

20N.cm

UCLA II Plus

20N.cm 20N.cm

Mini Ball Attachment 10N.cm

Cylinders

SELECTION OF PROSTHETIC COMPONENTS ACCORDING TO THE ABUTMENT/IMPLANT INTERFACE Working manner

Type of prosthesis

A. Overdenture Abutment

1. Screw-retained

Multipl e Prosthesis

Singl e Prosthesis

•Mini Conical Abutment •Transepithelial Abutment •Micro abutment

•Conical Abutment •CM Abutment

Multipl e Prosthesis

Singl e Prosthesis

2. Cemented •Universal Post •Personalizable Post

•Anatomical Post •Universal Post •Personalizable Post

B. Directl y on the Implant Multipl e Prosthesis

Singl e Prosthesis

•UCLA

Multipl e Prosthesis

Singl e Prosthesis

•UCLA

9


The implant with impermeable fitting that optimizes bacterial sealing and the health of peri-implant tissue.

COMPONENTS INDICATION TABLE

.5 m

m

Ø

Im

pla n

t

Ø3

.0 m

ØI

mp lan t

10

m

Internal Thread Ø 1.8

ø2

Internal Thread Ø 1.8

MORSE TAPER MORSE TAPER

Screw-retained Prosthesis •CM Abutment (single) •CM Mini Abutment (multiple) •CM Angled Mini Abutment 17° and 30° (multiple) •CM Micro Abutment (multiple)

Cemented Prosthesis •CM Angled Universal Post 17° and 30° •CM Universal Post Through Screw •CM Universal Post (single body) •Anatomical Post in Titanium

3.5, 3.75, 4.0, 4.3 and 5.0 mm MORSE TAPER WS ZYGOMATIC CM

4.0, 5.0 and 6.0 mm

•WS Abutment (single) •Ws Mini Abutment (multiple) •CM Transepithelial Abutment (multiple)

•WS Universal Post with Through Screw

Overdenture •CM Mini Ball Attachment

Protocol •CM Micro Abutment •CM Mini Abutment •CM Angled Mini Conical Abutment 17° and 30° •Cylinder and Distal Bar Passive Fitting Technique •Castable Cylinder – Mini Abutment •Titanium Cylinder – Mini Abutment •Brass Cylinder – Mini Abutment

•WS Mini Abutment (single) Passive Fitting Technique •Castable Cylinder – Mini Abutment •Titanium Cylinder – Mini Abutment •Brass Cylinder – Mini Abutment


Morse

Ta p e r

• • • • • •

GAP reduced (impermeable fitting); Stable Anti-rotational fixing; High mechanical strength; Unique prosthetic interface, independent of the implant diameter; First system with Morse Taper fitting in Brazil; The CM angle and the internal thickness of the implant enable the design of the screw thread to reach the cervical portion of the implant; • High resistance, comparable to implants with external hex with regular platform; •NeoPoros Surface.

Capture and Transport of the Implant Specific drivers to the hexagonal prosthetic indexer in the implant, available for contra-angle or ratchet, allow the capture of the implants directly on the package. The replacement of old mounts for these drivers guarantees greater resistance to torque, more faster and safety on procedures.

Drivers The installation drivers have six markings which match with the six faces of the hexagonal prosthetic index of implant. At the installation moment, one of these markings in driver should be in vestibular position, facilitating thus the posterior prosthetic procedure.

Indexer The hexagonal prosthetic index simplifies the implant installation process, reduces surgical time, increases the resistance to insertion torque and allows dentists to install the prosthesis already with a forecast for the positioning of the crown regarding the implant, thus providing even more safety, speed and flexibility to clinical and laboratorial works.

Exact Line Apart from the single CM interface for all implant diameters, the CM implants now have one more family of prosthetic components, the EXACT LINE. This line features have at their tip a hex index that allows positioning the prosthesis over the implant (prosthetic indexing), making our Morse Tapers line even more flexible.

11


h c u n a L

Product Characteristics: •Morse Taper interface; •NeoPoros Surface; •Implant with conical central nucleus; •Cervical conicity to reduce the compressive tension; •Double and progressive threads; •Cutting chambers in counterclockwise direction; •Apical thread with blade shape; •The installation is performed with specific drivers to the index of the implant, providing the implant capture directly on packaging, offering more safety and speed; •Suitable for bones type III and IV and pos-extracting installation; •Unique prosthetic interface for all implant diameters; •Best prosthetic resolution with CM Implant 2mm infraosseous; •Perforation rotation: 500-800 rpm; •Insertion rotation: 30 rpm.

Alvim Drill 5.0

Alvim Drill 4.3

Alvim Drill 3.5

Alvim Drill 2.0

Initial Drill

Drill sequence

3.5 mm 4.3 mm 5.0 mm

Code 8.0 mm

10.0 mm

11.5 mm

13.0 mm

16.0 mm

Ø 3.5

109.692

109.682

109.693

109.683

109.684

Ø 4.3

109.689

109.688

109.627

109.628

109.629

Ø 5.0

109.690

109.685

109.691

109.686

109.687

CM Cover Screw 2 mm

117.013

117.017

•Use Digital Driver 1.2mm (104.007) for installation; •Do not exceed torque of 10 N.cm.

Healings

12

0.8 mm

1.5 mm

2.5 mm

3.5 mm

4.5 mm

5.5 mm

Ø 3.3

106.182

106.168

106.169

106.170

106.183

106.184

Ø 4.5

106.175

106.171

106.172

106.173

106.174

106.180

•Use Digital Driver 1.2mm (104.007) for installation; •Do not exceed torque of 10 N.cm.


DEMONSTRATION SEQUENCE

Spear-point bur

Alvim 2.0 bur

Capture from package

Installation using counter-angle wrench

Alvim 3.5 bur

Alvim 4.3 bur

Installation using turnstile wrench

Implant inserted

CLINICAL CASE STUDY

Lingual

* Images kindly provided by Dr. Geninho Thomé, ILAPEO, Curitiba (PR) – Brazil.

Immediate

3 months

10 months

10 months

The DRIVE CM implant conical shape allowed its apex to be perfectly adjusted to the sublingual gland’s duct.

ex With h etic prosth index

The bio-medical concept of DRIVE CM implants with Switch Platform has preserved the bone crest’s architecture.

The preservation of marginal bone structures provided by the Morse Taper and Switch Platform maintained a good soft tissues cervical level of the temporary crown.

13


Product Characteristics: •Cylindrical implant with Morse Taper interface; •NeoPoros Surface; •The installation is performed with specific drivers to the index of the implant, providing the implant capture directly on packaging, offering more safety and speed; •Double thread (faster installation and less trauma); •High cutting capacity; •Suitable for bones type I and II and grafting areas in block; •Cover screw not included; •Unique prosthetic interface for all implant diameters; •Cervical diameter equal to implant diameter; •Observe the specific Pilot Drill (countersink function); •Better prosthetic resolution with CM Implant inserted 2mm infraosseous; •Perforation rotation: 800-1200 rpm; •Insertion rotation: 30 rpm.

Drill sequence CM Pilot 4.3/5.0

Titamax Drill 4.3

Titamax Drill 3.8

CM Pilot 3.3/4.0

Pilot CM 3/3.75

Titamax Drill 3.3

CM Pilot 2.8/3.5

Titamax Drill 3.15

Titamax Drill 3.0

Titamax Drill 2.8

Pilot 2/3

Titamax Drill 2.0

Initial Drill

Optional

3.5 mm 3.75 mm 4.0 mm 5.0 mm

Code 7.0 mm

8.0 mm

9.0 mm

11.0 mm

13.0 mm

15.0 mm

17.0 mm

CM Cover Screw 2 mm

Ø 3.5

109.613

109.614

109.615

109.616

109.617

109.618

109.619

Ø 3.75

109.606

109.607

109.608

109.609

109.610

109.611

109.612

Ø 4.0

109.630

109.631

109.632

109.633

109.620

109.634

109.635

Ø 5.0

109.642

109.643

109.644

109.645

109.646

0.8 mm

1.5 mm

2.5 mm

3.5 mm

4.5 mm

5.5 mm

Ø 3.3

106.182

106.168

106.169

106.170

106.183

106.184

Ø 4.5

106.175

106.171

106.172

106.173

106.174

106.180

117.013

117.017

•Use Digital Driver 1.2mm (104.007) for installation; •Do not exceed torque of 10 N.cm.

Healings

14

•Use Digital Driver 1.2mm (104.007) for installation; •Do not exceed torque of 10 N.cm.


Morse Taper

Product Characteristics: •Cylindrical implant with Morse Taper interface; •NeoPoros Surface; •The installation is performed with specific drivers to the index of the implant, providing the implant capture directly on packaging, offering more safety and speed; •Double thread (faster installation and less trauma); •High compaction capacity (bone expansion); •Suitable for bones type III and IV and in areas with little bone thickness; •Cover screw not included; •Unique prosthetic interface for all implant diameters; •Cervical diameter equal to implant diameter; •Simplified instrumentation in the prepare of surgical alveolus; •Best prosthetic resolution with CM Implant 2mm infraosseous; •Perforation rotation: 800-1200 rpm; •Insertion rotation: 30 rpm.

Drill sequence Titamax Drill 3.0

Titamax Drill 2.8

Pilot 2/3

Titamax Drill 2.0

Initial Drill

Optional

3.5 mm 3.75 mm 4.0 mm

Code 9.0 mm

11.0 mm

13.0 mm

Ø 3.5

109.661

109.662

109.663

109.664

109.665

Ø 3.75

109.666

109.667

109.668

109.669

109.670

Ø 4.0

109.636

109.637

109.638

109.639

109.640

CM Cover Screw

15.0 mm 17.0 mm

2 mm

117.013

117.017

•Use Digital Driver 1.2mm (104.007) for installation; •Do not exceed torque of 10 N.cm.

Healings •Use Digital Driver 1.2mm (104.007) for installation; 0.8 mm

1.5 mm

2.5 mm

3.5 mm

4.5 mm

5.5 mm

Ø 3.3

106.182

106.168

106.169

106.170

106.183

106.184

Ø 4.5

106.175

106.171

106.172

106.173

106.174

106.180

•Do not exceed torque of 10 N.cm.

15


Product Characteristics: • Conical implant with Morse Taper interface; • NeoPoros Surface; • The installation is performed with specific drivers to the index of the implant, providing the implant capture directly on packaging, offering more safety and speed; • Double thread (faster installation and less trauma); • Suitable for bones type III and IV and pos-extracting installation; • Cover screw not included; • Cervical diameter equal to implant diameter; • Unique prosthetic interface for all implant diameters; • Observe the specific Pilot Drill (function countersink); • Best prosthetic resolution with CM Implant 2mm infraosseous; • Perforation rotation: 500-800 rpm; • Insertion rotation: 30 rpm.

CM Pilot 4.3/5.0

Alvim Drill 5.0

CM Pilot 3.6/4.3

Alvim Drill 4.3

CM Pilot 2.8/3.5

Alvim Drill 3.5

Alvim Drill 2.0

Initial Drill

Drill Sequence

3.5 mm 4.3 mm 5.0 mm

Code 8.0 mm

10.0 mm

11.5 mm

13.0 mm

CM Cover Screw

16.0 mm

Ø 3.5

109.657

109.658

109.659

109.621

109.660

Ø 4.3

109.647

109.648

109.649

109.622

109.651

Ø 5.0

109.652

109.653

109.654

109.655

109.656

2 mm

117.013

117.017

•Use Digital Driver 1.2mm (104.007) for installation; •Do not exceed torque of 10 N.cm.

Healings

16

0.8 mm

1.5 mm

2.5 mm

3.5 mm

4.5 mm

5.5 mm

Ø 3.3

106.182

106.168

106.169

106.170

106.183

106.184

Ø 4.5

106.175

106.171

106.172

106.173

106.174

106.180

•Use Digital Driver 1.2mm (104.007) for installation; •Do not exceed torque of 10 N.cm.


Morse Taper

Medullar and Cortical

Product Characteristics: •Cylindrical implant with Morse Taper interface; •NeoPoros Surface; •Pre-mounted; •Cover screw not included; •Optimization of primary stability; •Excellent alternative to posterior edentulous lower jaw; •Specific Surgical Kit; •Observe the specific Pilot Drill (same function of countersink drill); •In Medullar Titamax WS Implant, the pilot drill is optional; •Perforation rotation: 200-300 rpm; •Insertion rotation: 30 rpm; •Unique Morse Taper prosthetic interface (same dimensions as CM Zygomatic Implants).

CM Pilot 5.3/6.0

Titamax Drill 5.3

CM Pilot 4.3/5.3

CM Pilot 4.3/5.0

Titamax Drill 4.3

CM Pilot 3.8/4.3

Titamax Drill 3.8

CM Pilot 3.3/4.0

CM Pilot 3/3.75

Titamax Drill 3.3

CM Pilot 2.8/3.5

Titamax Drill 3.0

Titamax Drill 2.8

Pilot 2/3

Initial Drill

Titamax Drill 2.0

Drill Sequence

4.0 mm 5.0 mm 6.0 mm Obligatory for Cortical Implant and Optional for CM Medullar Implant

Code Cortical

5.0 mm

6.0 mm

Ø 4.0

109.604

109.605

Ø 5.0

109.574

109.575

Ø 6.0

109.576

109.577

Medullar

5.0 mm

6.0 mm

Ø 5.0

109.578

109.579

Ø 6.0

109.580

109.581

WS Cover Screw 117.016

WS Healings 0.8 mm

1.5 mm

2.5 mm

3.5 mm

106.186

106.187

106.188

106.189

17


Demonstrative sequence of

CM Abutment and WS Abutment •Same prosthetic sequence as the GT Implant; •Available in Titanium; •Minimum interocclusal space of 5.0mm from the mucosa level; •Conicity 15°; •Single screw-retained prosthesis (anti-rotational); •The cylinders come with Neotorque screw, except the castables, that comes with Titanium screw.

CM Abutment

WS Abutment

0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm 115.162

115.147

115.148

115.152

115.163

115.164

0.8 mm 1.5 mm 2.5 mm 3.5 mm 115.180

115.181

115.182

GT Cylinder

GT Transfer Open Tra y

108.039

Closed Tra y

Castabl e

118.180

108.040

Titanium

118.179

CoCr

118.242

GT Analogue 101.037

GT Protective Cylinder 106.102

18

115.183

GT Cylinder Screw Titanium

Neotorque

116.038

116.228


Demonstrative sequence of

CM Mini Abutment and WS CM Angled Mini Abutment •Available in Titanium; •Minimum interocclusal space of 4.4mm from the mucosa level; •Multiple and screw-retained prosthesis; •Conicality 20°; •The cylinders come with Neotorque screw, except the castables, that comes with Titanium screw.

CM Angled Mini Conical Abutment

CM Mini Conical Abutment

1.5 mm 2.5 mm 3.5 mm

0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm 115.154

115.149

115.150

115.151

115.153

115.160

170

115.166

115.167

115.168

300

115.169

115.170

115.171

WS Mini Conical Abutment

Cylinder Mini Conical Abutment

0.8 mm 1.5 mm 2.5 mm 3.5 mm 115.176

115.177

115.178

Castabl e

Titanium

Nobl e

CoCr

CoCr for welding

118.112

118.113

118.206

118.209

118.210

115.179

Ø 4.1

Transfer of Mini Conical Abutment Open Tra y

Closed Tra y

Multifunctional

Ø 4.1

108.022

108.021

108.068

Short Screw

116.036

Cylinder Screw

Ø 4.1

101.020

Neotorque

116.037

116.227

Protective Cylinder of Mini Conical Abutment

Analogue of Mini Conical Abutment Ø 4.1

Titanium

Ø 4.1

106.054

19


Demonstrative sequence of

CM Micro Abutment 3.5

•Available in Titanium; •Multiple and screw-retained prosthesis; •Indicated to CM Implants with diameter of 3.5mm and close to each other; •Minimum interocclusal space of 4.4mm from the mucosa level; •Prosthetic fitting diameter of 3.3mm ; •The cylinders come with Neotorque screw, except the castables, that comes with Titanium screw.

Protective Cylinder of CM Micro Abutment

CM Micro Abutment 1.5 mm 2.5 mm 3.5 mm 115.200

115.201

Transfer of CM Micro Abutment

Cylinder of CM Micro Abutment

Rotational

Titanium

108.070

118.246

Analogue of CM Micro Abutment 101.057

20

106.199

115.202

CoCr

118.245

Castabl e

118.247

Cylinder Screw Titanium

Neotorque

116.037

116.227


Demonstrative sequence of

CM and Exact Anatomic Post

•Available in Titanium; •Cemented unitary prosthesis; •Possible customization; •Indicated for aesthetic area; •Height of anatomic prosthetic components available on page 55.

Lateral Exact CM Anatomic Post

Exact CM Anatomic Post 1.5 mm 2.5 mm 3.5 mm

1.5 mm 2.5 mm 3.5 mm

114.422 114.423 114.424

114.425 114.426 114.427

Lateral CM Anatomic Post

CM Anatomic Post 1.5 mm 2.5 mm 3.5 mm

1.5 mm 2.5 mm 3.5 mm

114.328

114.419

114.329 114.330

CM Implant Transfer

Conventional

Open Tra y

Closed Tra y

108.069

108.041

Short

108.065

Exact

108.076

114.420

114.421

CM Implant Analogue 101.058

21


Demonstrative sequence of

CM Universal Post

•Available in Titanium; •Cemented single prosthesis; •Straight component with single body.

CM Universal Post

Ø 4.5 Ø 3.3 Ø 4.5

6 mm

Ø 3.3

4 mm

0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm 114.129

114.077 114.078 114.079

114.136

114.137

114.131

114.080 114.081

114.082

114.142

114.143

114.130

114.086 114.087 114.088

114.139

114.140

114.132

114.083

114.145

114.146

114.084 114.085

108.043 108.045

Ø 3.3 Ø 4.5 Ø 3.3 Ø 4.5

Ø 3.3 Ø 4.5 22

4 mm 6 mm

Ø 4.5

108.060

Ø 3.3

108.062

Ø 4.5

108.061

Ø 3.3

108.063

Ø 4.5

Provisional

118.186

118.181

118.192

118.188

118.183

118.194

118.187

118.182

118.193

118.189

118.184

118.195

Universal Post Analogue

Universal Post Set Ø 3.3

4 mm

108.044

6 mm

Ø 4.5

Aluminum Castable

108.042

4 mm

Ø 3.3

Universal Post Cylinder

6 mm

Ø 4.5

6 mm

Ø 3.3

4 mm

Universal Post Transfer

101.038 101.040 101.039 101.041


Demonstrative sequence of

CM Universal Post Through Screw Exact CM Universal Post WS Universal Post •Available in Titanium; •Cemented single prosthesis; •Indicated for laboratorial customization.

Exact CM Universal Post

Ø 4.5 Ø 3.3 Ø 4.5

6 mm

Ø 3.3

4 mm

0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm 114.408 114.360

114.361

114.362

114.363 114.364

114.357 114.358

114.359

114.372

114.409 114.366 114.367

114.368

114.369 114.370

114.342

114.375

114.410

114.411

114.340

114.341

CM Universal Post Through Screw

Ø 4.5

114.150

114.151

114.152

114.153

114.115

114.117

114.118

114.119

114.162

114.163

114.155

114.156

114.157

114.158

114.159

114.160

114.116

114.120

114.121

114.122

114.165

114.166

CM Implant Transfer

Conventional

Open Tra y

Closed Tra y

108.069

108.041

Short

108.065

Exact

108.076

WS

108.064

Ø 4.5

4 mm

4 mm

114.149

0.8 mm 1.5 mm 2.5 mm 3.5 mm 114.183

114.184

114.185

114.186

6 mm

Ø 3.3

6 mm

Ø 4.5

114.148

114.376

WS Universal Post

0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm Ø 3.3

114.373

114.187

114.188

114.189

114.190

Analogue CM

WS

101.058

101.055

23


Demonstrative sequence of

Universal Post Angled CM and Exact •Available in Titanium; •Cemented single prosthesis.

Exact CM Angled Universal Post

CM Angled Universal Post 1.5 mm 2.5 mm 3.5 mm

Ø 3.3 300

Ø 4.5 Ø 3.3 Ø 4.5

114.391

114.392

Ø 4.5 170

114.387 114.388 114.389

Ø 3.3

114.393 114.394 114.395

Ø 4.5

114.396

114.397

114.398

Ø 3.3

114.402

114.403

114.404

Ø 4.5 300

114.399

114.400

114.401

Ø 3.3

114.405

114.406

114.407

Ø 4.5

108.045

Ø 3.3 Ø 4.5

Ø 3.3 Ø 4.5

24

4 mm 6 mm

Ø 4.5

114.092 114.093 114.094 114.098 114.099

114.100

114.101

114.102

114.103

114.107

114.108

114.109

114.104

114.105

114.106

114.110

114.111

114.112

108.060

Ø 3.3

108.062

Ø 4.5

108.061

Ø 3.3

108.063

Ø 4.5

Provisional

118.186

118.181

118.192

118.188

118.183

118.194

118.187

118.182

118.193

118.189

118.184

118.195

Universal Post Analogue

Universal Post Set Ø 3.3

4 mm

Ø 4.5

6 mm

Ø 4.5

108.043

Ø 3.3

4 mm

Ø 3.3

114.095 114.096 114.097

Aluminum Castable

108.042 108.044

114.089 114.090 114.091

Universal Post Cylinder

6 mm

Ø 4.5

6 mm

Ø 3.3

4 mm

Universal Post Transfer

4 mm

114.390

Ø 3.3

6 mm

114.385 114.386

4 mm

Ø 4.5

114.384

6 mm

Ø 3.3

6 mm

Ø 4.5

4 mm

170

6 mm

Ø 3.3

4 mm

1.5 mm 2.5 mm 3.5 mm

101.038 101.040 101.039 101.041


Demonstrative sequence of

CM Mini Ball Attachment •Available in Titanium; •Application of Nitride Titanium coating for increased the wear resistance; •Directly over the implant; •For Overdenture prosthesis, its function is the O’ring retention; •It’s recommended capture the components in patient’s mouth, one by one; •Obligatory to use positioner for capture; •O’ring with protection disc; •See the demonstrative sequence of Mini Ball Attachment on page 126.

Castable Ball Attachment

CM Mini Ball Attachment 1.5 mm 2.5 mm 3.5 mm 4.5 mm 102.069 102.070 102.071

Positioners recto, 70 e 140

102.076

O’ring with Cylinder 102.073

Mini O’ring 102.075

102.078

102.097

Protection Disk 102.077

O’ring Remover 104.044

O’ring Mount 104.043

25


The solution to the limitations of conventional external hexagon.

• Ensures the integrity of external hexagon; • Maintains original rotational freedom; • More practicality and safety; • Increased mechanical strength to the insertion; • Transport tweezers to the safety in handling the implant.

Area of Internal torque.

26

Tweezers that ensures increased safety in the implant transport.


Externa l Hex

COMPONENTS INDICATION TABLE

Hex 2.37 mm

1 mm

Ø3

.3

mm

He x2

Internal Thread Ø 1.8

EXTERNAL HEX

Internal Thread Ø 2.0

.1 m

m

Ø 4.1

Ø

4.3

mm He x3

.3

1 mm

Ø

5.0

mm

mm

Internal Thread Ø 2.0

1 mm

Internal Thread Ø 2.5

m

•Angled Post 17° •Castable UCLA •Titanium UCLA •CoCr UCLA

•SF Mini Conical Abutment (multiple) •Angled Mini Conical Abutment 17°and 30° (multiple) •SF Conical Abutment (single) •Castable UCLA •Noble UCLA •CoCr UCLA

•Angled Post 17° and 30° •Universal Post •Customizable Post •Castable UCLA •Noble UCLA •Titanium UCLA •CoCr UCLA

•Mini Ball Attachment

•Mini Conical Abutment (multiple) •Angled Mini Conical Abutment 17°and 30° (multiple) •Conical Abutment (single) •Castable UCLA •CoCr UCLA

•Angled Post 17° •Universal Post •Castable UCLA •Titanium UCLA •CoCr UCLA

•Mini Ball Attachment

Protocol

Ø 4.3

Ø 5.0

4.5 and 5.0 mm

•Mini Conical Abutment •Angled Mini Conical Abutment 17°and 30° •Cylinder and Distal External Bar Passive Fitting Technique •Castable Cylinder of Mini Abutment •Titanium Cylinder of Mini Abutment •Brass Cylinder of Mini Abutment

4.3 mm •SF Mini Conical Abutment (multiple) •Angled Mini Conical Abutment 17° and 30° (multiple) •SF Conical Abutment (1 piece) •Castable UCLA •CoCr UCLA

•Mini Conical Abutment •Angled Mini Conical Abutment 17°and 30° •Cylinder and Distal External Bar Passive Fitting Technique •Castable Cylinder of Mini Abutment •Titanium Cylinder of Mini Abutment •Brass Cylinder of Mini Abutment

3.75 and 4.0 mm

He x2

.7 m

Overdenture

3.3 and 3.5 mm

m

Ø4

Cemented Prosthesis

•Castable UCLA •CoCr UCLA

Ø 3.3

.7 m

0.7 mm

Screw-retained Prosthesis

•Angled Post 17° •Customizable Post •Castable UCLA •Titanium UCLA •CoCr UCLA

•Mini Ball Attachment

•Mini Conical Abutment •Angled Mini Conical Abutment 17°and 30° •Cylinder and Distal External Bar Passive Fitting Technique •Castable Cylinder of Mini Abutment •Titanium Cylinder of Mini Abutment •Brass Cylinder of Mini Abutment

27


Product Characteristics: •Cylindrical implant with External Hex interface; •NeoPoros Surface; •Capture and installation with contra-angle or manual without mount use (reduction of surgical time); •Installation by the internal hexagon of the implant, increasing the mechanical strength when high torques are applied, preserving the integrity of the external hexagon; •Double thread (faster installation and less trauma); •High cutting capacity; •Suitable for bones type I and II and grafting areas in block •Cover screw and mount not included; •Prosthetic platform: 4.1mm and 5.0mm; •Perforation rotation: 800-1200 rpm; •Installation rotation: 30 rpm.

Drill Sequence Countersink 5.0 SF

Titamax Drill 4.3

Titamax Drill 3.8

Countersink 4.1 SF

Pilot 3/3.75

Titamax Drill 3.3

Titamax Drill 3.15

Titamax Drill 3.0

Pilot 2/3

Initial Drill

Titamax Drill 2.0

Optional

3.75 mm 4.0 mm 4.5 mm 5.0 mm

Code

Cover Screw 7.0 mm

Ø 3.75

Platform (4.1)

Ø 4.0 Ø 4.5

Platform (5.0)

Ø 5.0

11.0 mm

13.0 mm

15.0 mm

17.0 mm

109.284

109.285

109.286

109.287

109.288

109.302

109.303

109.304

109.305

109.306

109.327

109.328

109.329

109.295

109.296

109.297

109.294

Divergent Healings

28

4.1 mm

5.0 mm

117.018

117.003

•Use Digital Driver 0.9mm (104.039) to the

Platform (4.1)

Platform (5.0)

9.0 mm

installation of Cover Screw platform 4.1 and Digital Driver 1.2mm (104.007) to the installation of Cover Screw platform 5.0; •Do not exceed torque of 10 N.cm.

Slim Fit Healings

2.0 mm

3.0 mm

4.0 mm

Ø 4.1

106.092

106.093

106.094

Ø 5.0

106.127

106.128

106.129

2.0 mm

3.0 mm

4.0 mm

Ø 4.1

106.190

106.191

106.192

Ø 5.0

106.195

106.196

106.197


Internal Torque

Product Characteristics: •Cylindrical implant with External Hex interface; •NeoPoros Surface; •Capture and installation with contra-angle or manual without mount use (reduction of surgical time); •Installation through implant internal hex, increasing the mechanical resistance (when applied elevated torque), preserving the external hex integrity; •Double thread (faster installation and less trauma); •High compaction capacity (bone expansion); •Suitable for bones type III and IV; •Cover screw not included; •Simplified instrumentation in the prepare of surgical alveolus; •Prosthetic platform 4.1mm; •Perforation rotation: 800-1200 rpm; •Installation rotation: 30 rpm.

Titamax Drill 3.0

Titamax Drill 2.8

Pilot 2/3

Initial Drill

Titamax Drill 2.0

Drill Sequence

3.75 mm 4.0 mm Optional

Code

Ø 3.75

Platform (4.1)

Ø 4.0

Platform (4.1)

Cover Screw 9.0 mm

11.0 mm

13.0 mm

15.0 mm

17.0 mm

109.582

109.583

109.584

109.585

109.586

109.588

109.589

109.590

109.591

109.592

117.018

•Use Digital Driver 0.9mm (104.039) to the installation of Cover Screw platform 4.1; •Do not exceed torque of 10 N.cm.

Slim Fit Healings

Divergent Healings

Ø 4.1

4.1 mm

2.0 mm

3.0 mm

4.0 mm

106.092

106.093

106.094

Ø 4.1

2.0 mm

3.0 mm

4.0 mm

106.190

106.191

106.192

29


Product Characteristics: •Conical implant with External Hex interface; •NeoPoros Surface; •Capture and installation with contra-angle or manual without mount use (reduction of surgical time); •Installation through implant internal hex, increasing the mechanical resistance (when applied elevated torque), preserving the external hex integrity; •Suitable for bones type III and IV and pos-extracting installation; •Cover screw and mount not included; •External Hex with height of 1mm: platform 4.3 and 5.0; •Perforation rotation: 500-800 rpm; •Installation rotation: 30 rpm.

Countersink 5.0 SF

Alvim Drill 5.0

Countersink 4.3

Alvim Drill 4.3

Alvim Drill 3.5

Alvim Drill 2.0

Initial Drill

Drill Sequence

4.3 mm 5.0 mm Optional

Code

Cover Screw 10.0 mm

Ø 4.3

109.321

13.0 mm 109.322

16.0 mm

4.3 mm

5.0 mm

117.006

117.003

109.323

•Use Digital Driver 0.9mm (104.039) to the installation of Cover Screw

Ø 5.0

109.324

109.325

platform 4.3 and Digital Driver 1.2mm (104.007) to the installation of Cover

109.326

Screw platform 5.0; •Do not exceed torque of 10 N.cm.

Divergent Healings

30

Parallel Healings

2.0 mm

3.0 mm

4.0 mm

Ø 4.3

106.140

106.141

106.142

Ø 5.0

106.127

106.128

106.129

Ø 4.3

Slim Fit Healings

2.0 mm

3.0 mm

4.0 mm

106.132

106.133

106.134

Ø 5.0

2.0 mm

3.0 mm

4.0 mm

106.195

106.196

106.197


Cortical with Mount

Product Characteristics: •Cylindrical implant with External Hex; •NeoPoros Surface; •Cover screw not included; •Double thread (faster installation and less trauma); •High cutting capacity; •Suitable for bones type I and II in reduced prosthetic spaces (upper lateral incisor and lower incisor); •Prosthetic platform 3.3mm; •External Hex with height of 1mm; •Resistance to the installation torque: 45 N.cm; •Perforation rotation: 800-1200 rpm; •Installation rotation: 30 rpm.

Countersink 3.3

Titamax Drill 2.8

Titamax Drill 2.0

Initial Drill

Drill Sequence

Code Cover Screw 9.0 mm

11.0 mm 13.0 mm

15.0 mm

17.0 mm 3.3 mm

Ø 3.3

109.140

109.141

109.142

109.143

117.001

109.144

•Use Digital Driver 0.9mm (104.039) to the installation of Cover Screw platform 4.3; •Do not exceed torque of 10 N.cm.

Parallel Healings

Divergent Healings

Ø 3.3

2.0 mm

3.0 mm

4.0 mm

106.065

106.066

106.067

Ø 3.3

2.0 mm

3.0 mm

4.0 mm

106.060

106.061

106.062

31


with Mount

Product Characteristics: •Conical implant with External Hex; •NeoPoros Surface; •Cover screw not included; •Suitable for bones type III and IV in reduced prosthetic spaces (upper lateral incisor and lower incisor) and pos-extracting installation; •Prosthetic platform 3.3mm; •External Hex with height of 1mm; •Resistance to the installation torque: 45 N.cm; •Perforation rotation: 500-800 rpm; •Installation rotation: 30 rpm.

Countersink 3.3

Alvim Drill 3.5

Alvim Drill 2.0

Initial Drill

Drill Sequence

Optional

Code Cover Screw 10.0 mm 13.0 mm 16.0 mm

Ø 3.5

Platform (3.3)

3.3 mm 109.217

109.218

109.219

117.001

•Use Digital Driver 0.9mm (104.039) for the installation of Cover Screw platform 3.3; •Do not exceed torque of 10 N.cm.

Parallel Healings

Divergent Healings

Ø 3.3

32

2.0 mm

3.0 mm

4.0 mm

106.065

106.066

106.067

Ø 3.3

2.0 mm

3.0 mm

4.0 mm

106.060

106.061

106.062


Finite Element Analysis of External Hex Implants

Application of Torque (70 N.cm) Implants with mount

Application of Torque (70 N.cm) Internal Torque Implants

An accumulation of stress may be observed at the edges of the external hex of the implant with mount, which does not occur in the internal torque implant, as the torque takes place in regions which do not compromise the Abutment/Implant adaptation. * images extracted from the doctoral thesis of ThomĂŠ, G. SĂŁo Leopoldo Mandic, Campinas, 2007

Comparative Microscopy

EH Implant with mount following application

EH Implant with internal torque following application

of a 70 N.cm torque

of a 70 N.cm torque

33


Demonstrative sequence of

Conical Abutment External Hex •Available in Titanium; •Minimum interocclusal space of 6.1mm on platform 4.1, and 6.7mm on platform 5.0mm, from the mucosa level; •Conicality 15°; •Single screw-retained prosthesis (anti-rotational); •Cylinders with screw; •Slim Fit components, that minimize bone remotion of the Countersink Drill, facilitating the intermediate seating and the tissue accommodation.

Protective Cylinder of Conical Abutment

Slim Fit

Conical Abutment 1 mm

2 mm

3 mm

Ø 4.1

115.192

115.193

115.194

Ø 4.3

115.051

115.052

115.053

Ø 5.0

115.007

115.008

115.009

Ø 4.1

106.051

Ø 5.0

106.052

Conical Abutment Transfer Open Tra y

Closed Tra y

Ø 4.1

108.035

108.075

Ø 5.0

108.025

108.104

Conical Abutment Cylinder Castabl e

Titanium

Ø 4.1

118.106

118.107

118.233

Ø 5.0

118.110

118.111

118.253

Conical Abutment Analogue Ø 4.1 Ø 5.0

34

Cylinder Screw of Conical Abutment Titanium

101.027 101.030

CoCr

Neotorque

Ø 4.1

116.004

116.231

Ø 5.0

116.005

116.232


Demonstrative sequence of

Mini Conical Abutment Angled Mini Conical Abutment External Hex •Available in Titanium; •Minimum interocclusal space of 4.4mm on platform 4.1, and 4.8mm on platform 5.0mm, from the mucosa level; •Screw-retained and multiple prosthesis (rotational); •Conicality 20°; •Mini Angled Abutment presents 12 positions of fitting; •The cylinders come with Neotorque screw, except the castables, that comes with Titanium screw; •Slim Fit components improve tissue accommodation, installed after using Countersink Drill, which minimizes bone removal.

Angled Mini Conical Abutment

Slim Fit

Slim Fit

Mini Conical Abutment 1 mm

2 mm

3 mm

Ø 3.3

115.134

115.135

115.136

4 mm

Ø 4.1

115.187

115.188

115.189

115.190

Ø 4.3

115.054

115.055

115.056

115.057

Ø 5.0

115.197

115.198

115.199

2 mm

3 mm

4 mm

Ø 3.3

115.137

115.138

115.139

Ø 4.1

115.084

115.074

115.075

115.076

115.077

115.078

170 Ø 4.3

300

Closed Tra y

Ø 4.1

108.022

108.021

Ø 5.0

108.024

108.023

Tornillo Short

116.036

115.094 115.095 115.096

Ø 4.1

115.140

115.141

Ø 4.3

115.111

115.112

Ø 5.0

115.143

115.144

Mini Conical Abutment Cylinder

Mini Conical Abutment Transfer Open Tra y

Ø 5.0

Castabl e

Titanium

Nobl e

CoCr

Ø 4.1

118.112

118.113

118.206

118.209

Ø 5.0

118.114

118.115

Multifunctional

108.068

Mini Conical Abutment Analogue Ø 4.1

101.020

Ø 5.0

101.022

CoCr for welding

118.210

118.240

Cylinder Screw of Mini Conical Abutment Titanium

Neotorque

Ø 4.1

116.037

116.227

Ø 5.0

116.038

116.228

Protective Cylinder of Mini Conical Abutment Ø 4.1

106.054

Ø 5.0

106.055

35


Demonstrative sequence of

SF Universal Post External Hex

•Available in Titanium; •Cemented prosthesis; •The Universal Post can be prepared according to circunstances, and, in this case, the prosthetic sequence can not be used; •Compatible with platform 4.1 and 4.3 External Hex; •Screw not included, for single elements select Neotorque Screw; •Available in two heights of cemented area: 4 or 6mm.

4 mm

SF Universal Post

Hex Screw

1 mm

2 mm

3 mm

114.428

114.429

114.430

114.431

114.432

116.002

108.044

Ø 4.5

4 mm

Universal Post Analogue 101.040

6 mm

4 mm

116.180

114.433

Universal Post Transfer

101.041

6 mm

Ø 4.5 108.045

108.063

Ø 4.5

4 mm

108.062

Ø 4.5 6 mm

Universal Post Cylinder

6 mm

4 mm

Universal Post Set

36

Titanium

Ø 4.3

Ø 4.5 6 mm

Ø 4.1

Neotorque

Aluminum

Castabl e

Provisional

118.188

118.183

118.194

118.189

118.184

118.195


Demonstrative sequence of

Customizable Post Angled Post External Hex • Available in Titanium; • Cemented prosthesis; • Angled Post presents 12 positions of fitting, and include Titanium screw; • Customizable Post without screw. It is recommended to use the Neotorque screw.

Angled Post 2 mm

170

300

3 mm

Customizable Post

4 mm

Ø 3.3

114.025 114.026

114.027

Ø 4.1 para Ø 5.0

114.029

Ø 4.1

114.016

114.017

114.018

Ø 4.1

Ø 6.0

114.030

Ø 4.3

114.049 114.050

114.051

Ø 5.0

Ø 5.0

114.071

114.072

114.073

114.009

114.010

Ø 4.1

para

para

Ø 6.0

114.035

Implant Analogue

Ø 3.3

101.001

Ø 4.1

101.004

101.003

Ø 4.3

101.028

101.024

Ø 5.0

101.006

101.005

Hex Screw

Ø 3.3 Ø 4.1

Neotorque

Titanium

116.188

116.001

116.180

116.002

Ø 4.3 Ø 5.0

116.189

116.003

Implant Transfer

Anti-rotational

Brass

101.002

Rotational

Titanium

Closed Tra y

Open Tra y

Ø 3.3

108.001

108.006

Ø 4.1

108.003

108.067 (SF)

Ø 4.3

108.029

108.034

Ø 5.0

108.013

108.011

Ø 3.3

108.002

Ø 4.1

108.066 (SF)

Ø 4.3

108.038

Ø 5.0

108.012

37


Demonstrative sequence of

UCLA External Hex

•Prosthetic component directly over the implant hex; •For screw-retained or cemented prosthesis; •Available in Rotational or Anti-Rotational; - Tilite and CoCr: overcastting; - Castable: casting; - Titanium: Provisional or Cemented Prosthesis - Gold: Overcasting with high melting range leagues. •With Titanium and Neotorque screw; •For unitary elements, select Neotorque screw.

Hex Screw

Rotational

Anti-rotational

UCLA Cobalto-Cromo (Cocr)

Castabl e

Titanium

118.212

118.001

118.008

118.004

118.009

118.101

118.097 118.040

Ø 3.3 Ø 4.1

Ø 3.3 118.204

118.235

Ø 4.3 Ø 5.0

118.237

118.006

Ø 3.3

118.211

118.002

Ø 4.1

118.030

118.119

118.152

Ø 4.1

118.236

Anti-rotational

Closed Tra y

Rotational

116.188

116.001

116.180

116.002

116.189

116.003

Ø 4.3 Ø 5.0

118.205

118.007

Implant Analogue

Implant Transfer

38

Titanium

118.234

Ø 4.3 Ø 5.0

118.005

Neotorque

Nobl e

Ø 3.3

108.001

Ø 4.1

108.003

Ø 4.3

108.029

Ø 5.0

108.013

Ø 3.3

108.002

Ø 4.1

108.066 (SF)

Ø 4.3

108.038

Ø 5.0

108.012

Open Tra y

Titanium

Brass

108.006

Ø 3.3

101.002

101.001

108.067 (SF)

Ø 4.1

101.004

101.003

108.034

Ø 4.3

101.028

101.024

108.011

Ø 5.0

101.006

101.005


Demonstrative sequence of

Mini Ball Attachment External Hex

•Available in Titanium; •Application of Nitride Titanium coating to increase the wear resistance; •Directly over the implant; •It´s recommended capture the components in patient’s mouth, one by one; •O’ring with protection disc; •See the demonstrative sequence of Mini Ball Attachment on page 126.

Castable Ball Attachment

Mini Ball Attachment 2 mm

3 mm

4 mm

Ø 4.1

102.060 102.061

Ø 4.3

102.063 102.064 102.065

Ø 5.0

102.066 102.067 102.068

Positioners recto, 70 e 140

102.076

O’ring with Cylinder 102.073

Mini O’ring 102.075

102.078

102.062

Protection Disk 102.077

O’ring Remover 104.044

O’ring Mount 104.043

39


Deep internal interface which provides more stability and resistance between screw and component.

TABLA DE INDICACIÓN DE COMPONENTES INTERNAL HEX

2.6

Pla

tfo rm

di

am

40

et er

m

m

Implant diameter

Internal thread Ø 1.6

HE X 2.5 AGO m N m

3.75, 4.3 and 5.0 mm Diameter of Prosthetic Platform

4.3 and 5.0 mm

Screw-retained Prosthesis •Mini Conical Abutment II Plus (multiple) •UCLA CoCr II Plus (single) •Conical Abutment II Plus (single) •Angled Conical Abutment II Plus (multiple)

Cemented Prosthesis •Universal Post II Plus •Angled Post II Plus 17° and 30° •UCLA CoCr II Plus (single) •UCLA Titanium II Plus (single)

Overdenture •Attachment Mini Ball II Plus

Protocol •Angled Conical Abutment II Plus •Conical Abutment II Plus •Cylinder and Ext. Distal Bar Passive Fitting Technique •Castable – Mini Abutment Cylinder •Titanium – Mini Abutment Cylinder •Brass – Mini Abutment Cylinder


Interna l Hex

•Prosthetic components with reduced platform in relation to the implant (Switching Platform); •Installation driver with tweezers to increase the transport security and the implant placement; •Cervical microretentions to bone tissue maintenance; •Unique prosthetic sequence independent of the implant platform diameter.

Prosthetic components with reduced platform in relation to the implant (Switching Platform).

Cervical micro-retentions.

41


Product Characteristics: 5.0

•Cylindrical implant with Internal Hex interface; 3.8

•NeoPoros Surface; •Double thread (faster installation and less trauma); •High cutting capacity; •Suitable for bones type I and II and areas of block grafting; •Cover screw not included; •Unique prosthetic interface for all implant diameters; •Perforation rotation: 800-1200 rpm; •Installation rotation: 30 rpm.

Prosthetic components with reduced platform in relation to the implant (Switching Platform).

Drill Sequence Countersink II 5.0

Titamax Drill 4.3

Titamax Drill 3.8

Countersink II 4.3

Pilot 3/3.75

Titamax Drill 3.15

Titamax Drill 3.0

Pilot 2/3

Titamax Drill 2.0

Initial Drill

Optional

3.75 mm 5.0 mm

CODE

Ø 3.75 Platform (4.3)

Ø 5.0

42

7.0 mm

9.0 mm

11.0 mm

109.462

109.463

109.464

13.0 mm 15.0 mm

Cover Screw 109.465

117.014

109.474

109.475

109.476

109.477

Healings

109.466 2.0 mm

3.0 mm

4.0 mm

106.176

106.177

106.178


Product Characteristics: 5.0

•Conical implant with Internal Hex interface; 3.8

•NeoPoros Surface; •Suitable for bones type III and IV and pos-extracting installation; •Cover screw not included; •Unique prosthetic interface for all implant diameters; •Perforation rotation: 500-800 rpm; •Installation rotation: 30 rpm.

Prosthetic components with reduced platform in relation to the implant (Switching Platform).

Drill sequence Countersink II 5.0

Alvim Drill 5.0

Countersink II 4.3

Alvim Drill 4.3

Alvim Drill 3.5

Alvim Drill 2.0

Initial Drill

Optional

4.3 mm 5.0 mm

CODE 10.0 mm 13.0 mm 16.0 mm

Cover Screw

Ø 4.3

109.478

109.479

Ø 5.0

109.481

109.482

Healings

109.480 117.014 109.483

2.0 mm

3.0 mm

4.0 mm

106.176

106.177

106.178

43


CLINICAL CASE STUDY

1 - Occlusal view of the edentulous area.

2 - Vestibular view of the case.

3 - Implant mount driver with installation pliers.

9 - Image of the implant platform after removing the healing abutment

10 - Universal trunnion II plus. These intermediate pieces are available at brace height options of 1, 2 and 3 mm, and are likewise available at different heights as regards the cementable part: 4 or 6 mm. This picture shows universal trunnion II Plus of 3 x 6 mm

11 - Detail of the interface area of universal trunnion [munhão] II Plus, which will come into contact with the implant.

4 - Image of the selected implant for rehabilitation of the clinical case.

5 - Capture with the handpiece mount driver, observe that the implant is not provided with a mount driver from the factory. Image of the selected implant for rehabilitation of the clinical case.

6 - EImplant primary stability diagnosed through the screw test.

7 - Immediate postoperative view of the case, occlusal view.

8 - View one week after the surgery, visit for suture removal.

44

12 - Examples of universal trunnion analogs and molding components. The yellow color indicates the use of a universal trunnion of cementable height of 4 mm, whereas the blue color is indicated for a trunnion of height 6.

13 - Occlusal and vestibular view of the final ceramic prosthesis.

THOMÉ, G; BERNARDES, S.R; SARTORI, I.M; PLATFORM SWITCHING Concept for INTERNAL HEXAGON IMPLANTS A clinical case report JORNAL DO ILAPEO, número 3, 2009.


Demonstrative sequence of

Conical Abutment II Plus Angled Conical Abutment II Plus INTERNAL HEX

•Available in Titanium; •Minimum interocclusal space of 6.1mm from the mucosa level; •Conicality 15°; •Single screw-retained prosthesis (anti-rotational); •Concept Switching Platform; •Compatible components with implants diameter (Ø 3.75, Ø 4.3 and Ø 5.0); •The cylinders come with Neotorque screw, except the castables, that comes with Titanium screw.

Angled Conical Abutment II Plus 170

Conical Abutment II Plus 1.0 mm

2.0 mm

3.0 mm

2.0 mm

3.0 mm

4.0 mm

115.184

115.185

115.186

115.203

115.204

115.205

108.075

108.020

ø 4.1

108.018

Conical Abutment Analogue ø 4.1

101.027

Titanium

CoCr

118.106

118.107

118.233

118.104

118.105

118.232

Castable

Anti-rotational

108.035

Conical Abutment Cylinder II Plus

Rotational

Closed Tra y

Anti-rotational

ø 4.1

Open Tra y

Rotational

Conical Abutment Transfer

Cylinder Screw of Conical Abutment Titanium

Neotorque

116.004

116.231

Protective Cylinder of Conical Abutment ø 4.1

106.051

45


Demonstrative sequence of

Mini Conical Abutment II Plus INTERNAL HEX

•Minimum interocclusal space of 4.4mm from the mucosa level; •Screw-retained and multiple prosthesis (rotational); •Conicality 20°; •Concept Switching Platform; •Compatible component with implants diameter II Plus (Ø 3.75, Ø 4.3 and Ø 5.0); •The cylinders come with Neotorque screw, except the castables, that comes with Titanium screw.

Mini Conical Abutment II Plus

Protective Cylinder of Mini Conical Abutment

1 mm

2 mm

3 mm

4 mm

115.155

115.156

115.157

115.158

Ø 4.1

Mini Conical Abutment Transfer

106.054

Mini Conical Abutment Cylinder

Closed Tra y

Cubeta Abierta

Multifunctional

Ø 4.1

108.022

108.021

108.068

Tornillo Short

116.036

Castable

Ø 4.1

118.112

46

118.113

Nobl e

CoCr

118.206

118.209

Cylinder Screw of Mini Conical Abutment

Mini Conical Abutment Analogue Ø 4.1

Titanium

Titanium

Neotorque

116.037

116.227

101.020

Ø 4.1

CoCr for welding

118.210


Demonstrative sequence of

Universal Post II Plus INTERNAL HEX

•Available in Titanium; •Cemented prosthesis; •The Universal Post can be prepared according to circunstances, and, in this case, the prosthetic sequence can not be used; •Compatible component with implants diameter II Plus (Ø 3.75, Ø 4.3 and Ø 5.0); •Screw not included. For single elements, use Neotorque Screw; •Available in two heights of cemented area: 4 or 6mm.

Hex Screw II Plus 2 mm

3 mm

4 mm

Ø4.5

1 mm 114.123

114.124

114.125

6 mm

Universal Post

114.126

114.127

114.128

Neotorque

Titanium

116.226

116.224

108.044

Ø 4.5

4 mm

Universal Post Analogue

101.040

6 mm

4 mm

Universal Post Transfer

101.041

6 mm

Ø 4.5 108.045

108.062

Ø 4.5 6 mm

Ø 4.5 108.063

4 mm

Universal Post Cylinder

6 mm

4 mm

Universal Post Set

Aluminum

Castable

Provisional

118.188

118.183

118.194

118.189

118.184

118.195

47


Demonstrative sequence of

Angled Post II Plus INTERNAL HEX

•Available in Titanium; •Cemented prosthesis; •With 6 fitting positions; •Titanium screw included.

Angled Post II Plus

170

2 mm

3 mm

4 mm

114.171

114.172

114.173

114.174

114.175

300

Implant Transfer Open Tra y

108.046

108.047

Anti-rotational

Closed Tra y

Analogue II Plus

48

Ø 4.3

101.032

Ø 5.0

101.034


Demonstrative sequence of

UCLA II Plus INTERNAL HEX

•Prosthetic component directly over the implant; •For screw-retained or cemented prosthesis; •Available in rotational or anti-rotational models; •Available in: -CoCr: overcasting; -Titanium: provisional or cemented prosthesis; •Screw not included; •For unitary elements, select Neotorque screw.

UCLA II Plus

Rotational

Anti-rotational

Titanium

Hex Screw II Plus Neotorque

Cobalto-Cromo (Cocr)

116.226

118.185

Titanium

116.224

118.214

118.213

Implant Analogue II Plus

Implant Transfer Closed Tra y

Open Tra y

108.046

108.047

Ø 4.3

101.032

49


Demonstrative sequence of

Mini Ball Attachment II Plus •Available in Titanium; •Application of Nitride Titanium coating for increased the wear resistance; •Directly over the implant; •It´s recommended capture the components in patient’s mouth, one by one; •Obligatory to use positioner for capture; •O’ring with protection disc; •See the demonstrative sequence on page 126.

Mini Ball Attachment II Plus 2 mm

3 mm

102.090 102.091

4 mm

102.076

O’ring with Cylinder 102.073

Mini O’ring 102.075

50

102.078

102.092

Positioners recto, 70 y 140

Castable Ball Attachment

Protection Disk 102.077

O’ring Remover 104.044

O’ring Mount 104.043


m

0.7 m

m

4.1

.0 m Ø3

mm 2.7 Hex

Ø

m

m

Product Characteristics: • Cylindrical implant; • Morse Taper interface, with different dimensions of the conventional implants (same dimensions of WS Titamax Implant) or External Hex 4.1mm; • Smooth surface; • Pre-mounted; • Cover screw not included; • Double thread in CM Zygomatic version; • It is indicated to use the Transepithelial Abutment according to the prosthetic interface.

Observation: This technique requires specific accreditation. Information on www.neodent.com.br.

Code 30.0 mm 109.522

External Hex

30.0 mm 109.460

35.0 mm 40.0 mm 45.0 mm 47.5 mm 50.0 mm 52.5 mm 109.523

109.450

117.016

•Use Digital Driver 1.2mm (104.007) to the

•Do not exceed torque of 10 N.cm.

109.525

109.526

109.527

Ø 4.4mm

109.528

35.0 mm 40.0 mm 45.0 mm 47.5 mm 50.0 mm 52.5 mm

Zygomatic CM Cover Screw

installation of Cover Screw;

109.524

109.451

109.452

109.461

109.453

109.454

External Hex Cover Screw

Nominal length

Morse Taper

Ø 3.9mm

4.1 mm 117.018

•Use Digital Driver 0.9mm (104.039) to the installation of Cover Screw; • Do not exceed torque of 10 N.cm.

51


Clinical Case Study

External Hex Zygomatic Implant

Occlusal view of case

Initial panoramic

View of the patient’s occlusion

Radiographic monitoring of 04 years

Aspect of case 09 months after implants installation

Clinical Case Study

Morse Taper Zygomatic Implant

Tomographic images showing the initial situation of the case

Final prosthesis over double zygomatic

Initial intraoral aspect

Radiographic aspect of the case 02 years after the implants installation

SARTORI, IAM; PADOVAN, LEM; HERMANN, C; BERNARDES, SR; CORÓ, V; THOMÉ, G. Os avanços da Implantodontia abrindo as perspectivas de tratamento. JORNAL DO ILAPEO, número 2, 2007

52


Demonstrative sequence of

Transepithelial Abutment •Available in Titanium; •Minimum interocclusal space of 4.5mm; •Screw-retained and multiple prosthesis; •Exclusive for Zygomatic Implants; •CM model compatible with WS Titamax Implant.

External Hex Transepithelial Abutment

Morse Taper Transepithelial Abutment

3 mm

4 mm

5 mm

3 mm

4 mm

5 mm

115.023

115.024

115.025

115.172

115.173

115.174

Transfer Transepithelial Abutment 108.026

Cylinder Transepithelial Abutment Castabl e

118.034

Analogue Transepithelial Abutment 101.018

CoCr

118.254

Cylinder Screw Titanium

Neotorque

116.004

116.231

Protective Cylinder Transepithelial Abutment 106.056

53


COMPACT SURGICAL KIT

The Compact Surgical Kit is a solution that Neodent offers to the installation of implants more used in clinical day to day. Available in two versions, with metal or Zirconia drills (high performance and durability advanced). The new kit also presents another important advantage: the Torque Ratchet Driver, which can be used both for surgery as for prosthesis.

Version of Zirconia Drills Code

54

Description

Version of Metal Drills Code

Description

103.170

INITIAL DRILL PLUS

103.170

INITIAL DRILL PLUS

103.162

TWIST DRILL 2.0 PLUS

103.162

TWIST DRILL 2.0 PLUS

103.269

PILOT DRILL 2/3 ZIRCONIA

103.213

PILOT DRILL 2/3 PLUS

103.244

TWIST DRILL 2.8 ZIRCONIA

103.163

TWIST DRILL 2.8 PLUS

103.245

TWIST DRILL 3.0 ZIRCONIA

103.164

TWIST DRILL 3.0 PLUS

103.253

ALVIM DRILL 3.5 ZIRCONIA

103.172

ALVIM DRILL 3.5 PLUS

103.254

ALVIM DRILL 4.3 ZIRCONIA

103.173

ALVIM DRILL 4.3 PLUS

103.292

COUNTERSINK DRILL 4.1 SF ZIRCONIA

103.239

COUNTERSINK DRILL 4.1 SF PLUS

103.267

COUNTERSINK DRILL 4.3 ZIRCONIA

103.211

COUNTERSINK DRILL 4.3 PLUS

103.272

CM PILOT DRILL 2.8/3.5 ZIRCONIA

103.216

CM PILOT DRILL 2.8/3.5 PLUS

103.273

CM PILOT DRILL 3/3.75 ZIRCONIA

103.217

CM PILOT DRILL 3/3.75 PLUS

103.275

CM PILOT DRILL 3.6/4.3 ZIRCONIA

103.219

CM PILOT DRILL 3.6/4.3 PLUS

103.091

DRILL EXTENSION

103.091

DRILL EXTENSION

105.047

Ti CONNECTION FOR CONTRA-ANGLE 4.1 AND 4.3

105.047

Ti CONNECTION FOR CONTRA-ANGLE 4.1 AND 4.3

105.045

SHORT Ti CONNECTION FOR RATCHET 4.1 AND 4.3

105.045

SHORT Ti CONNECTION FOR RATCHET 4.1 AND 4.3

105.046

LONG Ti CONNECTION FOR RATCHET 4.1 AND 4.3

105.046

LONG Ti CONNECTION FOR RATCHET 4.1 AND 4.3

105.073

SHORT CM CONNECTION FOR RATCHET

105.073

SHORT CM CONNECTION FOR RATCHET

105.074

LONG CM CONNECTION FOR RATCHET

105.074

LONG CM CONNECTION FOR RATCHET

105.075

CM CONNECTION FOR CONTRA-ANGLE

105.075

CM CONNECTION FOR CONTRA-ANGLE

104.039

SHORT DIGITAL DRIVER 0.9

104.039

SHORT DIGITAL DRIVER 0.9

104.007

SHORT DIGITAL DRIVER 1.2

104.007

SHORT DIGITAL DRIVER 1.2

104.050

TORQUE RATCHET DRIVER

104.050

TORQUE RATCHET DRIVER

128.019

PARALLEL INDICATOR 2.8/3.5

128.019

PARALLEL INDICATOR 2.8/3.5

128.020

PARALLEL INDICATOR 3/3.75

128.020

PARALLEL INDICATOR 3/3.75

128.022

PARALLEL INDICATOR 4.3/5.0

128.022

PARALLEL INDICATOR 4.3/5.0

110.254

COMPACT SURGICAL KIT CASE

110.254

COMPACT SURGICAL KIT CASE


Surgical Instruments

Concave Osteotomes 1.8 mm

2.5 mm 3.0 mm 3.5 mm 4.0 mm 4.5 mm

110.154

110.155

110.156

110.157

110.158

110.159

•Available in Surgical Stainless Steel; •Concave cutting tip for atraumatic elevation of maxillary sinus floor; •Used in the preparing of surgical alveolus for implants installation in posterior maxillary area whith less osseous height; •Markings from 7 to 17mm.

17 mm 13 mm 9 mm

15 mm 11 mm 7 mm

Spreading Osteotomes 1.8 mm 110.160

2.5 mm 3.0 mm 3.5 mm 110.161

110.162

110.163

•Available in Surgical Stainless Steel; •Convex tip; •Used when thickness bone is insufficient, requiring compression and prior bone expansion to the implant placement; •Markings from 7 to 17mm.

17 mm 13 mm 9 mm

15 mm 11 mm 7 mm

Surgical Mallet 126.001

•Available in Surgical Stainless Steel; •Active tip in polymer; •Used in Concave and Spreading Osteotomes; •Weight: 130g.

55


Long Sinus Curette

126.008 126.009

1

3

126.010

126.011

126.012

4

5

7

• Available in Surgical Stainless Steel; • Used for detachment of sinusal membrane.

Metal Bone Scraper 127.018

127.016

127.017

127.019

Negativo

Recto

Positivo

Lámina

•Used to remove autogenous bone applied in reconstructive surgery; •Includes a blade coated with Titanium Nitride; •Silicone handle; •Autoclavable.

Disposable Bone Scraper

127.023

•Used to remove autogenous bone; •Single use; •Supplied sterile.

Disposable Bone Collector •Available in polymer; •Used to collect autogenous bone; •Single use; •Adaptive to vacuum pump; •Two disposable sieves included; •Use the second tip to saliva suction (beware of contamination).

107.003

107.008

56


* illustra

tive im

a ge

Complete Kit: Bone Grafting and Orthodontic Anchorage 110.227 104.018 105.063 105.023 103.045 103.079 103.044 103.043 103.078 103.042 103.207 104.033 105.039 105.040 105.025

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Bone Grafting and Orthodontic Anchorage Case Bone Grafting Manual Driver Philips Connection for Manual Driver Philips Connection for Contra-angle Drill 1.6 for Contra-angle Drill 1.3 for Contra-angle Drill 1.1 for Contra-angle Drill 1.6 for Straight Piece Drill 1.3 for Straight Piece Drill 1.1 for Straight Piece Punch for Bone Grafting and Orthodontic Anchorage Orthodontic Anchorage Driver Contra-angle connection – Anchorage - Long Contra-angle connection – Anchorage – Short Ratchet Adaptor for contra-angle connections

57


Bone Grafting and Orthodontic Anchorage

1 m m

Hol e Diameter: 0,7mm

Hex Size: 2.7 mm

Screw for Bone Grafting 6 mm

8 mm

10 mm

12 mm

14 mm

Ø 1.5 mm 116.194

116.196

116.198

116.199

116.200

Ø 2.0 mm 116.203

116.205

116.207

116.209

Expanded head

8 mm

10 mm

12 mm

14 mm

Ø 1.5 mm

116.210

116.211

116.212

116.213

Ø 2.0 mm

116.214

116.215

116.216

•Available in Titanium; •Osseous block fixation; •Self-drilling.

Implants for Orthodontic Anchorage Band Expanded Head

58

Standart Head

Ø 1.5 mm

Ø 3.70mm

Ø 2.5 mm

Ø 2.0 mm

Ø 3.85 mm

Ø 3.0 mm

Ø 1.3mm

Low

5 mm

7 mm

9 mm

11 mm

109.484

109.485

109.486

Ø 1.3mm

Medium

109.487

109.488

109.489

Ø 1.6mm

Low

109.701

109.493

109.494

109.495

Ø 1.6mm

Medium

109.702

109.496

109.497

109.498

•Available in Titanium alloy according to ASTM-F136 (level V); •Implants for orthodontic movement; •Self-drilling; •Collar height: -Low: 0mm; -Medium: 1mm; •Torque resistance up to 10 N.cm (Ø 1.3mm) and 20 N.cm (Ø 1.6mm).


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.