Neodent HE Catalog

Page 1

The solution to the limitations of conventional external hexagon.

• Ensures the integrity of external hexagon; • Maintains original rotational freedom; • More practicality and safety; • Increased mechanical strength to the insertion; • Transport tweezers to the safety in handling the implant.

Area of Internal torque.

58

Tweezers that ensures increased safety in the implant transport.


Externa l Hex

COMPONENTS INDICATION TABLE

Hex 2.37 mm

1 mm

Ø3

.3

mm

He x2

Internal Thread Ø 1.8

EXTERNAL HEX

Internal Thread Ø 2.0

.1 m

m

Ø 4.1

Ø

4.3

mm He x3

.3

1 mm

Ø

5.0

mm

mm

Internal Thread Ø 2.0

1 mm

Internal Thread Ø 2.5

m

•Angled Post 17° •Castable UCLA •Titanium UCLA •CoCr UCLA

•SF Mini Conical Abutment (multiple) •Angled Mini Conical Abutment 17°and 30° (multiple) •SF Conical Abutment (single) •Castable UCLA •Noble UCLA •CoCr UCLA

•Angled Post 17° and 30° •Universal Post •Customizable Post •Castable UCLA •Noble UCLA •Titanium UCLA •CoCr UCLA

•Mini Ball Attachment

•Mini Conical Abutment (multiple) •Angled Mini Conical Abutment 17°and 30° (multiple) •Conical Abutment (single) •Castable UCLA •CoCr UCLA

•Angled Post 17° •Universal Post •Castable UCLA •Titanium UCLA •CoCr UCLA

•Mini Ball Attachment

Protocol

Ø 4.3

Ø 5.0

4.5 and 5.0 mm

•Mini Conical Abutment •Angled Mini Conical Abutment 17°and 30° •Cylinder and Distal External Bar Passive Fitting Technique •Castable Cylinder of Mini Abutment •Titanium Cylinder of Mini Abutment •Brass Cylinder of Mini Abutment

4.3 mm •SF Mini Conical Abutment (multiple) •Angled Mini Conical Abutment 17° and 30° (multiple) •SF Conical Abutment (1 piece) •Castable UCLA •CoCr UCLA

•Mini Conical Abutment •Angled Mini Conical Abutment 17°and 30° •Cylinder and Distal External Bar Passive Fitting Technique •Castable Cylinder of Mini Abutment •Titanium Cylinder of Mini Abutment •Brass Cylinder of Mini Abutment

3.75 and 4.0 mm

He x2

.7 m

Overdenture

3.3 and 3.5 mm

m

Ø4

Cemented Prosthesis

•Castable UCLA •CoCr UCLA

Ø 3.3

.7 m

0.7 mm

Screw-retained Prosthesis

•Angled Post 17° •Customizable Post •Castable UCLA •Titanium UCLA •CoCr UCLA

•Mini Ball Attachment

•Mini Conical Abutment •Angled Mini Conical Abutment 17°and 30° •Cylinder and Distal External Bar Passive Fitting Technique •Castable Cylinder of Mini Abutment •Titanium Cylinder of Mini Abutment •Brass Cylinder of Mini Abutment

59


Product Characteristics: •Cylindrical implant with External Hex interface; •NeoPoros Surface; •Capture and installation with contra-angle or manual without mount use (reduction of surgical time); •Installation by the internal hexagon of the implant, increasing the mechanical strength when high torques are applied, preserving the integrity of the external hexagon; •Double thread (faster installation and less trauma); •High cutting capacity; •Suitable for bones type I and II and grafting areas in block •Cover screw and mount not included; •Prosthetic platform: 4.1mm and 5.0mm; •Perforation rotation: 800-1200 rpm; •Installation rotation: 30 rpm.

Countersink 5.0 SF

Titamax Drill 4.3

Titamax Drill 3.8

Countersink 4.1 SF

Pilot 3/3.75

Titamax Drill 3.3

Titamax Drill 3.15

Titamax Drill 3.0

Pilot 2/3

Titamax Drill 2.0

Initial Drill

Drill sequence

3.75 mm 4.0 mm 4.5 mm 5.0 mm Optional

60


Externa l Hex

7.0 mm

9.0 mm

11.0 mm

13.0 mm

15.0 mm

17.0 mm

109.284

109.285

109.286

109.287

109.288

109.302

109.303

109.304

109.305

109.306

109.327

109.328

109.329

109.295

109.296

109.297

Ø 3.75 Platform (4.1)

Ø 4.0

Platform (4.1)

Ø 4.5

Platform (5.0)

Ø 5.0 Platform (5.0)

109.294

•Use Digital Driver 0.9mm (104.039) to the

Cover Screw 4.1 mm

5.0 mm

117.018

117.003

installation of Cover Screw platform 4.1 and Digital Driver 1.2mm (104.007) to the installation of Cover Screw platform 5.0; •Do not exceed torque of 10 N.cm.

Divergent Healings

Slim Fit Healings

2.0 mm

3.0 mm

4.0 mm

Ø 4.1

106.092

106.093

106.094

Ø 5.0

106.127

106.128

106.129

2.0 mm

3.0 mm

4.0 mm

Ø 4.1

106.190

106.191

106.192

Ø 5.0

106.195

106.196

106.197

61


Internal Torque

Product Characteristics: •Cylindrical implant with External Hex interface; •NeoPoros Surface; •Capture and installation with contra-angle or manual without mount use (reduction of surgical time); •Installation through implant internal hex, increasing the mechanical resistance (when applied elevated torque), preserving the external hex integrity; •Double thread (faster installation and less trauma); •High compaction capacity (bone expansion); •Suitable for bones type III and IV; •Cover screw not included; •Simplified instrumentation in the prepare of surgical alveolus; •Prosthetic platform 4.1mm; •Perforation rotation: 800-1200 rpm; •Installation rotation: 30 rpm.

Titamax Drill 3.0

Titamax Drill 2.8

Pilot 2/3

Titamax Drill 2.0

Initial Drill

Drill sequence

3.75 mm 4.0 mm Optional

62


Externa l Hex

9.0 mm

11.0 mm

13.0 mm

15.0 mm

17.0 mm

109.582

109.583

109.584

109.585

109.586

109.588

109.589

109.590

109.591

109.592

Ø 3.75 Platform (4.1)

Ø 4.0

Platform (4.1)

•Use Digital Driver 0.9mm (104.039) to the

Cover Screw 4.1 mm

117.018

installation of Cover Screw platform 4.1; •Do not exceed torque of 10 N.cm.

Divergent Healings

Ø 4.1

Slim Fit Healings

2.0 mm

3.0 mm

4.0 mm

106.092

106.093

106.094

Ø 4.1

2.0 mm

3.0 mm

4.0 mm

106.190

106.191

106.192

63


Product Characteristics: •Conical implant with External Hex interface; •NeoPoros Surface; •Capture and installation with contra-angle or manual without mount use (reduction of surgical time); •Installation through implant internal hex, increasing the mechanical resistance (when applied elevated torque), preserving the external hex integrity; •Suitable for bones type III and IV and pos-extracting installation; •Cover screw and mount not included; •External Hex with height of 1mm: platform 4.3 and 5.0; •Perforation rotation: 500-800 rpm; •Installation rotation: 30 rpm.

Countersink 5.0 SF

Alvim Drill 5.0

Countersink 4.3

Alvim Drill 4.3

Alvim Drill 3.5

Alvim Drill 2.0

Initial Drill

Drill sequence

4.3 mm 5.0 mm Optional

64


Externa l Hex

10.0 mm

13.0 mm

16.0 mm

109.321

109.322

109.323

109.324

109.325

109.326

Ø 4.3

Ø 5.0

•Use Digital Driver 0.9mm (104.039) to the installation

Cover Screw 4.3 mm 117.006

5.0 mm 117.003

of Cover Screw platform 4.3 and Digital Driver 1.2mm (104.007) to the installation of Cover Screw platform 5.0; •Do not exceed torque of 10 N.cm.

Divergent Healings

Parallel Healings

2.0 mm

3.0 mm

4.0 mm

Ø 4.3

106.140

106.141

106.142

Ø 5.0

106.127

106.128

106.129

Ø 4.3

2.0 mm

3.0 mm

4.0 mm

106.132

106.133

106.134

Slim Fit Healings

Ø 5.0

2.0 mm

3.0 mm

4.0 mm

106.195

106.196

106.197

65


Cortical with Mount

Product Characteristics: •Cylindrical implant with External Hex; •NeoPoros Surface; •Cover screw not included; •Double thread (faster installation and less trauma); •High cutting capacity; •Suitable for bones type I and II in reduced prosthetic spaces (upper lateral incisor and lower incisor); •Prosthetic platform 3.3mm; •External Hex with height of 1mm; •Resistance to the installation torque: 45 N.cm; •Perforation rotation: 800-1200 rpm; •Installation rotation: 30 rpm.

66

Countersink 3.3

Titamax Drill 2.8

Titamax Drill 2.0

Initial Drill

Drill Sequence


9.0 mm

11.0 mm 13.0 mm

15.0 mm

17.0 mm

Ø 3.3

109.140

Cover Screw 3.3 mm

117.001

109.141

109.142

109.143

•Use Digital Driver 0.9mm (104.039) to the installation of Cover Screw platform 4.3; •Do not exceed torque of 10 N.cm.

Divergent Healings

Ø 3.3

109.144

Parallel Healings

2.0 mm

3.0 mm

4.0 mm

106.065

106.066

106.067

Ø 3.3

2.0 mm

3.0 mm

4.0 mm

106.060

106.061

106.062

67


with Mount

Product Characteristics: •Conical implant with External Hex; •NeoPoros Surface; •Cover screw not included; •Suitable for bones type III and IV in reduced prosthetic spaces (upper lateral incisor and lower incisor) and pos-extracting installation; •Prosthetic platform 3.3mm; •External Hex with height of 1mm; •Resistance to the installation torque: 45 N.cm; •Perforation rotation: 500-800 rpm; •Installation rotation: 30 rpm.

Countersink 3.3

Alvim Drill 3.5

Alvim Drill 2.0

Initial Drill

Drill sequence

Optional

68


10.0 mm 13.0 mm 16.0 mm

Ø 3.5 Platform (3.3) 109.217

Cover Screw 3.3 mm

117.001

109.218

109.219

•Use Digital Driver 0.9mm (104.039) for the installation of Cover Screw platform 3.3; •Do not exceed torque of 10 N.cm.

Divergent Healings

Ø 3.3

Parallel Healings

2.0 mm

3.0 mm

4.0 mm

106.065

106.066

106.067

Ø 3.3

2.0 mm

3.0 mm

4.0 mm

106.060

106.061

106.062

69


External Hex

The Slim Fit Line is the Neodent’s innovation for External Hex components, due to its parallel emergent profile which minimizes the bone renoval.

Reduced Osteotomy Get to know the benefits of the SLIM FIT line, and see how certain details can make all the difference: - Facilitates the fitting of the prosthetic component by reducing the interference with the cortical bone; - Preserves the cortical bone plates; - Optimizes installation; - Eases the procedures for soft tissue synthesis (stitching) by increasing the abutment’s conicity. CONVENTIONAL ABUTMENT WITH SF OSTEOTOMY

70

SF ABUTMENT WITH CONVENTIONAL OSTEOTOMY


Less Aggressive Drills For the SLIM FIT line, it is necessary to use the new

CONVENTIONAL OSTEOTOMY

SLIM FIT OSTEOTOMY (LESS BONE REMOVAL)

COUNTERSINK CONVENTIONAL

NEW DRILL COUNTERSINK SLIM FIT

Countersink SF Drill, which has a new shape that reduces the drilling diameter, reducing trauma and preserving the bone tissue.

Soft Tissue Accommodation

Emergent Profile Slim Fit

The SLIM FIT intermediaries provide an excellent accommodation of peri-implant soft tissue, easing the prosthetic procedures in surgical cases with immediate loading and tissue stabilization at long term. Emergent Profile Conventional

71


Demonstrative sequence of

Conical Abutment External Hex

Prosthetic Torque Ratchet Driver

Castabl e

Titanium

CoCr

Castabl e

Titanium

CoCr

Torque Connection 1.2

Conical Abutment Cylinder 4.1

Conical Abutment Cylinder 5.0

Protective Cylinder of Conical Abutment 4.1

Protective Cylinder of Conical Abutment 5.0

Conical Abutment Analogue 4.1

Conical Abutment Analogue 5.0

Conical Abutment Transfer 4.1 Closed Tra y

Conical Abutment Transfer 4.1 Open Tra y

Sequence 4.1 / 4.3 mm

Conical Abutment Transfer 5.0 Closed Tra y

Conical Abutment Transfer 5.0 Open Tra y

Sequence 5.0 mm

•Available in Titanium; •Minimum interocclusal space of 6.1mm on platform 4.1, and 6.7mm on platform 5.0mm, from the mucosa level; Prosthetic Torque Ratchet Driver

•Conicality 15°; •Single screw-retained prosthesis (anti-rotational); •Cylinders with screw; •Slim Fit components, that minimize bone remotion of the Countersink Drill, facilitating the intermediate seating and the tissue accommodation.

Prosthetic Abutment Driver

Torque Connection 1.6mm

20

N.cm

SF Conical Abutment 4.1mm

72

Conical Abutment 4.3mm

Conical Abutment 5.0mm


Slim Fit

Conical Abutment 1 mm

2 mm

3 mm

Ø 4.1

115.192

115.193

115.194

Ø 4.3

115.051

115.052

115.053

Ø 5.0

115.007

115.008

115.009

•Observe corresponding sequence to the component diameter and indicated torque; •For torque, use Prosthetic Abutment Driver (105.009), except for Ø 5.0 Torque Connection 1.6mm (105.006); •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Protective Cylinder of Conical Abutment Ø 4.1

106.051

Ø 5.0

106.052

•Available in Titanium; •Used to protect the component during the prosthesis construction; •To installation, use Digital Driver 1.2mm (104.007); •Observe the compatible diameter with the prosthetic component.

Conical Abutment Cylinder Castabl e

Conical Abutment Transfer Open Tra y

Closed Tra y

Ø 4.1

108.035

108.075

Ø 5.0

108.025

108.104

•Available in Titanium; •Component with molding function by prosthesis construction; •For open tray or closed tray technique; •Select transfer according to the component to be molded, as prosthetic planning; •Anti-rotational.

Titanium

CoCr

Ø 4.1

118.106

118.107

118.233

Ø 5.0

118.110

118.111

118.253

•Available in: Titanium: provisional prosthesis; CoCr: overcasting; Castable: casting. •Observe the corresponding sequence to the component diameter; •Screw included; •To screw torque, use Torque Conection 1.2mm (105.005); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026); •Anti-rotational.

Cylinder Screw of Conical Abutment

Conical Abutment Analogue Ø 4.1

101.027

Ø 5.0

101.030

•Available in Titanium; •Replica of implant platform or prosthetic component; •For prosthesis construction or prosthetic planning; •Observe compatible diameter with the prosthetic component.

Titanium

Neotorque

Ø 4.1

116.004

116.231

Ø 5.0

116.005

116.232

•Observe indicated torque; •Use Torque Connection 1.2mm (105.005); •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Neotorque

•Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in preload increase.

73


Demonstrative sequence of

Mini Conical Abutment Angled Mini Conical Abutment External Hex

Prosthetic Torque Ratchet Driver

Castabl e

Titanium

CoCr

Castabl e

Titanium

Nobl e / CoCr

Torque Connection 1.2

Cylinder of Mini Conical Abutment 4.1

Cylinder of Mini Conical Abutment 5.0

Protective Cylinder of Mini Conical Abutment 4.1

Protective Cylinder of Mini Conical Abutment 5.0

Mini Conical Abutment Analogue 4.1

Mini Conical Abutment Analogue 5.0

Closed Tra y Transfer Mini Conical Abutment 4.1

Closed Tra y Transfer Mini Conical Abutment 5.0

Open Tra y Transfer Mini Conical Abutment 4.1

Sequence 3.3 / 4.1 / 4.3 mm

Open Tra y Transfer Mini Conical Abutment 5.0

Sequence 5.0 mm

•Available in Titanium; •Minimum interocclusal space of 4.4mm on platform 4.1, and 4.8mm on platform 5.0mm, from the mucosa level; Prosthetic Torque Ratchet Driver

•Screw-retained and multiple prosthesis (rotational); •Conicality 20°; •Mini Angled Abutment presents 12 positions of fitting; •The cylinders come with Neotorque screw, except the castables, that comes with Titanium screw; •Slim Fit components improve tissue accommodation, installed after using Countersink Drill, which minimizes bone removal.

Torque Connection 1.2 mm

20

32

Prosthetic Abutment Driver

20

Torque Connection 1.6mm

32

N.cm

N.cm

Angl ed Mini

SF Mini Conical

Mini Conical Abutment

SF Mini Conical

Abutment 17 0 and 30 0

Abutment 4.1mm

3.3 mm / 4.3 mm

Abutment 5.0 mm

N.cm

74

Prosthetic Abutment Driver

N.cm


Angled Mini Conical Abutment

Slim Fit

Slim Fit

Mini Conical Abutment 1 mm

2 mm

3 mm

4 mm

Ø 3.3

115.134

115.135

115.136

Ø 4.1

115.187

115.188

115.189

115.190

Ø 4.3

115.054

115.055

115.056

115.057

Ø 5.0

115.197

115.198

115.199

2 mm

3 mm

4 mm

Ø 3.3

115.137

115.138

115.139

Ø 4.1

115.084

115.074

115.075

115.076

115.077

115.078

170 Ø 4.3

•Observe corresponding sequence to the component diameter; •For torque, use Prosthetic Abutment Driver (105.009), except for Ø 5.0 Torque Connection 1.6mm (105.006); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Ø 5.0

115.094 115.095 115.096

Ø 4.1

115.140

115.141

Ø 4.3

115.111

115.112

Ø 5.0

115.143

115.144

300

•Minimum interocclusal space of 5.0mm for 17º and 5.5mm for 30º; •Screw-retained and multiple prosthesis (rotational); •Observe corresponding sequence to the component diameter; •For torque, use Torque Connection 1.2 (105.005); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Mini Conical Abutment Cylinder

Mini Conical Abutment Transfer Open tra y

Closed tra y

Ø 4.1

108.022

108.021

Ø 5.0

108.024

108.023

Short Screw

116.036

Castabl e

Multifunctional

108.068

•Available in Titanium; •Component with molding function to the prosthesis confection; •For Open Tray or Closed Tray technique; •Select the transfer in accordance with the component to be moulded conforming to the planned prosthetics; •Rotational.

101.020

Ø 5.0

101.022

Nobl e

CoCr

118.206

118.209

Ø 4.1

118.112

118.113

Ø 5.0

118.114

118.115

CoCr for welding

118.210

118.240

•Available in: Titanium: provisional prosthesis; CoCr: overcasting; Castable: casting; Noble: gold alloy with high melting range. •Screw included; •Observe the corresponding sequence to the component diameter; •To screw torque, use Torque Conection 1.2mm (105.005); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026); •Rotational for screw-retained multiple elements.

Mini Conical Abutment Analogue Ø 4.1

Titanium

Cylinder Screw of Mini Conical Abutment Titanium Neotorque

•Available in Titanium; •Replica of prosthetic component; •For prosthesis confection or prosthetic planning.

Ø 4.1 Ø 5.0

106.054

Ø 5.0

106.055

•Available in Titanium; •Used to protect the component during the prosthesis construction; •To installation, use Digital Driver 1.2mm (104.007); •Observe the compatible diameter with the prosthetic component.

116.227

116.038

116.228

•Observe indicated torque; •Use Torque Connection 1.2mm (105.005); •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Protective Cylinder of Mini Conical Abutment Ø 4.1

116.037

Neotorque

•Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in preload increase.

75


Demonstrative sequence of

SF Universal Post External Hex

Ø4.5

Ø4.5

Ø4.5

Universal Post Cylinder

Universal Post Cylinder

Universal Post Cylinder

Alumina

Provisional

Castabl e

Ø4.5

Universal Post Analogue

Ø4.5

Universal Post Transfer

Prosthetic Torque Ratchet Driver

4.5

Torque Connection 1.2

Transmucous

4 ou 6

32

4.1

N.cm Neotorque Screw

•Available in Titanium; •Cemented prosthesis; •The Universal Post can be prepared according to circunstances, and, in this case, the prosthetic sequence can not be used; •Compatible with platform 4.1 and 4.3 External Hex; •Screw not included, for single elements select Neotorque Screw; •Available in two heights of cemented area: 4 or 6mm. 76

SF Universal Post


Hex Screw

Ø 4.1

4 mm

SF Universal Post

Titanium

116.180

116.002

Ø 4.3

1 mm

2 mm

3 mm

114.428

114.429

114.430

114.431

114.432

114.433

•Observe indicated torque; •Use Torque Connection 1.2mm (105.005); •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Ø 4.5 6 mm

Neotorque

Neotorque

•Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in preload increase.

Universal Post Analogue

6 mm

4 mm

108.044

Ø 4.5

101.040

6 mm

4 mm

Universal Post Transfer

101.041

Ø 4.5

108.045

•Available in polymer; •Component with molding function to prosthesis confection; •For closed tray technique; •Select transfer according to the component to be molded, as prosthetic planning; •Anti-rotational.

•Available in Titanium; •Replica of prosthetic component; •For prosthesis confection or prosthetic planning.

Ø 4.5 108.062

6 mm

Ø 4.5 108.063

•Components Kit of Universal Post line, containing Transfer and Provisional / Castable Cylinders.

6 mm

4 mm

Universal Post Set

4 mm

Universal Post Cylinder Alumina

Castabl e

Provisional

118.188

118.183

118.194

118.189

118.184

118.195

• Available in: Acrylic: provisional prosthesis; Alumina: for “metal free” prosthesis; Castable: casting. • Compatible with all Universal Posts, if not prepared.

77


Demonstrative sequence of

Customizable Post Angled Post External Hex

Prosthetic Torque Ratchet Driver

Torque Connection 1.2

32

32

32

N.cm

N.cm

N.cm

Neotorque Screw 4.1mm

Neotorque Screw 5.0 mm

Titanium Screw

Customizabl e Post 4.1mm

Customizabl e Post 5.0mm

Angl ed Post (17 0 and 30 0 ) 3.3/ 4.1/ 4.3 / 5.0 mm

Implant Analogue 3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm

• Available in Titanium; • Cemented prosthesis; • Angled Post presents 12 positions of fitting, and include Titanium screw; • Customizable Post without screw. It is recommended to use the Neotorque screw.

78

Closed tra y Transfer

Open tra y Transfer

3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm

3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm


Angled Post 2 mm

170

300

3 mm

Ø 3.3

114.025 114.026

114.027

Ø 4.1

114.016

114.017

114.018

Ø 4.3

114.049 114.050

114.051

Ø 5.0

114.071

114.072

114.073

114.009

114.010

Ø 4.1

Customizable Post

4 mm

•Titanium screw included; •To torque, use Torque Connection 1.2mm (105.005); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026); •Anti-rotational.

Ø 4.1 para Ø 5.0

114.029

Ø 4.1 para Ø 6.0

114.030

Ø 5.0 para Ø 6.0

114.035

•To unitary elements, select Neotorque Screw; •Screw not included; •To installation, use Torque Connection 1.2mm (105.005); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Implant Analogue Titanium

Brass

Ø 3.3

101.002

101.001

Ø 4.1

101.004

101.003

Ø 4.3

101.028

101.024

Ø 5.0

101.006

101.005

•Available in Brass and Titanium; •Replica of implant platform; •For prosthesis construction and/or prosthetic planning.

Implant Transfer

Hex Screw

Ø 3.3 Ø 4.1

Neotorque

Titanium

116.188

116.001

116.180

116.002

116.189

116.003

Ø 4.3 Ø 5.0

• Observe indicated torque; • Use Torque Connection 1.2mm (105.005); • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Neotorque

Rotational

Anti-rotational

Closed tra y

Open tra y

Ø 3.3

108.001

108.006

Ø 4.1

108.003

108.067 (SF)

Ø 4.3

108.029

108.034

Ø 5.0

108.013

108.011

Ø 3.3

108.002

Ø 4.1

108.066 (SF)

Ø 4.3

108.038

Ø 5.0

108.012

•Available in Titanium; •Component with molding function by prosthesis construction; •For open tray or closed tray technique; •Select transfer according to the implant to be molded, as prosthetic planning.

•Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in preload increase.

79


Demonstrative sequence of

UCLA External Hex

Prosthetic Torque Ratchet Driver

Torque Connection 1.2

32

N.cm Neotorque Screw

UCLA 3.3 mm

UCLA 4.1 mm

UCLA 4.3 mm

UCLA 5.0 mm

Analogue 3.3 mm

Analogue 4.1 mm

Analogue 4.3 mm

Analogue 5.0 mm

•Prosthetic component directly over the implant hex; •For screw-retained or cemented prosthesis; •Available in Rotational or Anti-Rotational; - Tilite and CoCr: overcastting; - Castable: casting; - Titanium: Provisional or Cemented Prosthesis - Gold: Overcasting with high melting range leagues. •With Titanium and Neotorque screw; •For unitary elements, select Neotorque screw.

80

Closed Tra y Transfer

Open Tra y Transfer

3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm

3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm


UCLA

Rotational

Anti-rotational

Cobalt-Chromium (Cocr)

Ø 3.3

118.212

Ø 4.1

Castabl e

Titanium

118.001

118.008

118.004

118.009

118.101

118.097 118.040

Nobl e

118.204

118.235

Ø 4.3 Ø 5.0

118.237

118.006

Ø 3.3

118.211

118.002

Ø 4.1

118.005

118.030

118.119

118.152

118.205

118.234

Ø 4.3 Ø 5.0

118.236

118.007

Hex Screw Neotorque

Ø 3.3 Implant Transfer

Rotational

Anti-rotational

Closed Tra y

Ø 3.3

108.001

Ø 4.1

108.003

Ø 4.3

108.029

Ø 5.0

108.013

Ø 3.3

108.002

Ø 4.1

108.066 (SF)

Ø 4.3

108.038

Ø 5.0

108.012

Open Tra y

108.006 108.067 (SF)

Ø 4.1

Titanium

116.188

116.001

116.180

116.002

116.189

116.003

Ø 4.3 Ø 5.0

108.034

•Observe indicated torque; •Use Torque Connection 1.2mm (105.005); •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

108.011

Neotorque

•Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in preload increase.

•Available in Titanium; •Component with molding function by prosthesis construction; •For open tray or closed tray technique; •Select transfer according to the implant to be molded, as prosthetic planning.

Implant Analogue Titanium

Brass

Ø 3.3

101.002

101.001

Ø 4.1

101.004

101.003

Ø 4.3

101.028

101.024

Ø 5.0

101.006

101.005

•Available in Brass and Titanium; •Replica of implant platform; •For prosthesis construction and/or prosthetic planning.

81


Demonstrative sequence of

Mini Ball Attachment External Hex

O’ring with Cylinder

Protection Disk

Straight positioner

Positioner 70

Positioner 14 0

Prosthetic Torque Ratchet Driver

Prosthetic Abutment Driver

Protection Disk

Positioner

•Available in Titanium; •Application of Nitride Titanium coating to increase the wear resistance; •Directly over the implant; •It´s recommended capture the components in patient’s mouth, one by one; •O’ring with protection disc; •See the demonstrative sequence of Mini Ball Attachment on page 126.

82

32

N.cm Mini Ball Attachment 4.1

Mini Ball Attachment 4.3

Mini Ball Attachment 5.0


Castable Ball Attachment

Mini Ball Attachment 2 mm

3 mm

4 mm

Ø 4.1

102.060 102.061

Ø 4.3

102.063 102.064 102.065

Ø 5.0

102.066 102.067 102.068

102.062

102.078

•Casting in various metals; •May be cemented in natural roots or waxed in bars for overdenture retention.

•Select according to mucosa height; •To installation, use Prosthetic Abutment Driver (105.009); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Positioners straight, 70 and 140

102.076

•Available in polymer; •Defines the correct distance between Attachment Ball and O’ring; •Corrects the parallelism between implants; •Essential for O’ring capturing.

O’ring with Cylinder 102.073

•Available in Titanium (cylinder); •Available in polymer (O’ring); •Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention; •Not autoclavable.

Mini O’ring 102.075

•Available in polymer; •Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention; •Not autoclavable.

Protection Disk 102.077

•Package with 10 units.

O’ring Remover 104.044

•Digital Driver with function of O’ring replacing to the cylinder.

O’ring Mount 104.043

•Digital Driver with function of O’ring placement to the cylinder.

83


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.