Sales Centers
Novkabel AD Republic of Serbia, 21000 Novi Sad Industrijska bb Tel: +381 21 21 00 520 +381 21 21 00 521 Fax: +381 21 21 00 522 e-mail: info@novkabel.com www.novkabel.com Western Europe Representative: DP Handel GmbH Westendstrasse 45 D-60325 Frankfurt am Main, Germany Tel:+ 44 699714 8116 Fax: + 44 69 97 14 81 15 e-mail: biljana_dph@web.de
Company profile About us
Objective
The Cable Factory based in Novi Sad was established in 1921 and is the oldest cable factory in the Balkans.
NOVKABEL focuses on quality with utmost respect of the client’s needs producing cables in accordance with the quality standards and ecology requirements.Our goal is to remain the leading company in production and distribution of all types of cables by improving the sales, conquering new markets, expanding the distribution network and strengthening the relations with business partners.
We supply a wide range of energy cables and conductors, telecommunication cables and cables for electronic equipment to suit various industrial needs of construction industry, mining, shipbuilding, as well as oil, transportation, automotive industry and other industries.
NOVKABEL, a member of
Capacity Novkabel production plant occupies an area of almost 40 hectares in the industrial zone of Novi Sad with the production capacity of up to 35.000 tons per year.
Research and development
Point Group is a leading regional group with subsidiaries and associated companies that operate mainly in South East Europe. The core business activities of the Point Group are: copper processing and trading, wholesale grain trading, mill and bakery industry, river transport and real estate and engineering. The majority of the business operations take place in Serbia, Romania, Hungary and Austria. The Company also has offices in leading world cities: Moscow, New York, Frankfurt and Beijing.
NOVKABEL IS A RECOGNIZABLE PRODUCTION BRAND IN CABLE INDUSTRY OF SOUTHEAST EUROPE BEING A LEADING PROVIDER IN REGARD OF QUALITY AND PRODUCT RANGE.
From its modest beginnings in the product range, with the work of generations of employees on the development of new products, the factory has achieved about 16.000 registered products. NOVKABEL experts dedicate significant amounts of time to follow and implement the latest technical and technological achievements in cable production.
Quality We carry out all quality control procedures to ensure that all raw materials meet intake specifications and follow production until the dispatch of finished products; therefore, the investment into control equipment is one of Novkabel’s priorities.
NFK PpNiO
KПпНOБK-100
Polypropylene and nitrile rubber cable - round Standard: PSN Nominal voltage: 5 kV Test voltage: 10 kV
CONSTRUCTION Conductor: single-wire tinned copper conductor Insulation: polypropylene high electrical properties Sheath: special oil resistant molded mixture based on nitrile rubber Reinforcement: profiled galvanized steel strip
CONSTRUCTION DATA
02
nxq
Nominal cross section
Cable diameter
Diameter
Weight
mm2
mm2
mm
mm
kg/km
10 AWG 6/1 16 AWG 4/1
3,57 4,11 4,51 5,18
27,5 28 29 30
1290 1370 1590 1710
3x10 3x13,3 3x16 3x21,15
n – number of cores, q – nominal cross section of conductor Permissible conductor temperature: - operating temperature (constant load), max + 70°C - in short circuit (max 5 s), max + 160°C Permissible enviromental temperature: - at handling, - 30°C do + 100°C - permanent, - 40°C do + 100°C
NFK PpNiP
KПпНБП-100
Polypropylene and nitrile rubber cable- flat Standard: PSN Nominal voltage: 5 kV Test voltage: 10 kV
CONSTRUCTION Conductor: single-wire tinned copper conductor Insulation: polypropylene high electrical properties Sheath: over each core special oil-resistant mixture on the basis of nitrile rubber Reinforcement: profiled galvanized steel strip
CONSTRUCTION DATA nxq
Nominal cross section
Cable diameter
Diameter ~
Weight ~
mm2
mm2
mm
mm
kg/km
10 AWG 6/1 16 AWG 4/1
3,57 4,11 4,51 5,18
14,5 x 38 15 x 39 16 x 41 16,5 x 42
1240 1330 1510 1640
3x10 3x13,3 3x16 3x21,15
n – number of cores, q – nominal cross section of conductor Permissible conductor temperature: - operating temperature (constant load), max + 70°C - in short circuit (max 5 s), max + 160°C Permissible enviromental temperature: - at handling, - 30°C do + 100°C - permanent, - 40°C do + 100°C
03
NFK EpNiO
KЭНОБK-13
Ethylene polypropylene and nitrile rubber cable - round Standard: PSN Nominal voltage: 5 kV Test voltage: 10 kV
CONSTRUCTION Conductor: single-wire tinned copper conductor Insulation: mixture based on ethylene propylene rubber high electrical properties Tape/strip: temperature barrier Sheath: special oil resistant molded mixture based on nitrile rubber Reinforcement: profiled galvanized steel strip
CONSTRUCTION DATA
04
nxq
Nominal cross section
Cable diameter
Diameter ~
Weight ~
mm2
mm2
mm
mm
kg/km
10 AWG 6/1 16 AWG 4/1
3,57 4,11 4,51 5,18
26 27 29 30
1660 1750 1970 2110
3x10 3x13,3 3x16 3x21,15
n – number of cores, q – nominal cross section of conductor Permissible conductor temperature: - operating temperature (constant load), max + 90°C - in short circuit (max 5 s), max + 250°C Permissible enviromental temperature: - at handling, - 30°C do + 130°C - at laying, - 40°C do + 130°C
NFK EpNiP
KЭНБKП-130
Ethylene polypropylene and nitrile rubber cable - flat Standard: PSN Nominal voltage: 5 kV Test voltage: 10 kV
CONSTRUCTION Conductor: single-wire tinned copper conductor Insulation: mixture based on ethylene propylene rubber high electrical properties Sheath: through each core special oil-resistant mixture on the basis of nitrile rubber Tape / braid: temperature barrier protection against contact with reinforcement through each core Reinforcement: profiled galvanized steel strip
CONSTRUCTION DATA nxq
Nominal cross section
Cable diameter
Diameter ~
Weight ~
mm2
mm2
mm
mm
kg/km
10 AWG 6/1 16 AWG 4/1
3,57 4,11 4,51 5,18
14 x 39 14,5 x 39,5 15 x 42 15,5 x 42,5
1310 1400 1560 1700
3x10 3x13,3 3x16 3x21,15
n – number of cores, q – nominal cross section of conductor Permissible conductor temperature: - operating temperature (constant load), max + 90°C - in short circuit (max 5 s), max + 250°C Permissible enviromental temperature: - at handling, - 30°C do + 130°C - at laying, - 40°C do + 130°C
05
NFK EpEpO
KЭНОБK-230
Ethylene polypropylene cable - round Standard: PSN Nominal voltage: 5 kV Test voltage: 10 kV
CONSTRUCTION Conductor: single-wire tinned copper conductor Insulation: mixture based on ethylene propylene rubber high electrical properties Tape/strip: temperature barrier Sheath: special oil resistant molded mixture based on ethylene propylene rubber Reinforcement: profiled galvanized steel strip
CONSTRUCTION DATA
06
nxq
Nominal cross section
Cable diameter
Diameter ~
Weight ~
mm2
mm2
mm
mm
kg/km
10 AWG 6/1 16 AWG 4/1
3,57 4,11 4,51 5,18
25 26 27 28
1510 1600 1810 1950
3x10 3x13,3 3x16 3x21,15
n – number of cores, q – nominal cross section of conductor Permissible conductor temperature: - operating temperature (constant load), max + 90°C - in short circuit (max 5 s), max + 250°C Permissible enviromental temperature: - at handling, - 30°C do + 160°C - at laying, - 40°C do + 160°C
NFK EpO
KЭCБП-230
Ethylene polypropylene and lead cable - flat Standard: PSN Nominal voltage: 4 kV Test voltage: 10 kV
CONSTRUCTION Conductor: single-wire tinned copper conductor Insulation: mixture based on ethylene propylene rubber high electrical properties Lead sheath: a barrier that prevents decompression Tape / braid: protection against contact and lead fittings, through each core Reinforcement: profiled galvanized steel strip
CONSTRUCTION DATA nxq
Nominal cross section
Cable diameter
Diameter ~
Weight ~
mm2
mm2
mm
mm
kg/km
10 AWG 6/1 16 AWG 4/1
3,57 4,11 4,51 5,18
11 x 29 11 x 30 11.5 х 31 12 x 33
1700 1820 1950 2220
3x10 3x13,3 3x16 3x21,15
n – number of cores, q – nominal cross section of conductor Permissible conductor temperature: - operating temperature (constant load), max + 90°C - in short circuit (max 5 s), max + 250°C Permissible enviromental temperature: - at handling, - 40°C do + 230°C - at laying, - 50°C do + 230°C
07
Cables for oil wells represent a particular group of special cables intended for use in oil well conditions. They are used to power electric pumps located on the bottom of an oil well. They work under high-pressure, in aggressive environments and at elevated temperatures. They are manufactured in one length corresponding the depth of an oil well where it is to be installed. They are made either round or flat, for rated voltages of 3 kV, 4 kV and 5 kV most commonly accoring to specifications of manufacturers themselves. Conditions in wells are the main criteria for selecting the cable type. Polypropylene is used as the isolation material for lower operating temperatures. EPDM, which is especially made rubber compound based on ethylene propylene rubber with improved electrical properties, resistant to high temperatures and oil, is used as the isolation material for middle and higher operating temperatures. An important feature of these cable is a solid connection between conductors and isolation.
08
Sales Centers
Novkabel AD Republic of Serbia, 21000 Novi Sad Industrijska bb Tel: +381 21 21 00 520 +381 21 21 00 521 Fax: +381 21 21 00 522 e-mail: info@novkabel.com www.novkabel.com Western Europe Representative: DP Handel GmbH Westendstrasse 45 D-60325 Frankfurt am Main, Germany Tel:+ 44 699714 8116 Fax: + 44 69 97 14 81 15 e-mail: biljana_dph@web.de