Soft Drinks Factory

Page 1

E1

500.000 + 0.20

Staff And Trucks Entry

E3

+ 0.00

Green Area For Future Expansion And Pre-Cooling For Air

+ 0.10

Glass Raw Materials Handling Yard

+ 0.20 + 10.00

Adminstration Parking

+ 10.00

+ 0.10

S1

6

+ 15.00

0 .50 7 4

S1

+ 15.00

+ 0.20

+ 0.20

Green Area For Future Expansion And Pre-Cooling For Air

+ 13.00 + 10.00

Lo

+ 10.00

+ 11.00

+ 0.20

a

n di

g

Ba

y

+ 0.10

00 0.0 30

ng di l o sH k uc Tr

+ 0.10

4 .42 43

g kin r a sP r o sit Vi

+ 15.00

g kin r Pa

6

7 .16 5 1

t Lo 5 .40 9 5

7 .27 3 1

m 40

+ 0.20

St

20

m

re St

et

0 .00 0 40

re et + 10.00

E2

Green Area

+ 09.00 47 6.5 9 1

+ 0.20

Filling Hall Glass Bottles Manufacturing plant Administration Aluminum Cans Manufacturing Plant P.E.T Bottles Manufacturing Plant Warehouse E4

General Zoning

_Site Plan

_1:750

Obai Hasab Elrasoul Fifth Year Soft Drinks Factory _ Stage 5 _ 23/12/2012

1


E4

E1

+ 0.20

Staff And Trucks Entry

+ 0.00

Green Area For Future Expansion And Pre-Cooling For Air

+ 0.10 + 0.20

Electrical & A/C Room

Adminstration Parking

g in ur t ac uf n a M l s l e ttl Ha o sB as l G

Bottles Filling Hall

+ 0.10

+ 0.20

Warehouse

g kin r Pa rs o sit Vi

Syrup Prepn aratio

Green Area For Future Expansion And Pre-Cooling For Air

Lo

+ 0.20

+ 0.10

m 40 St re et

. P.E

um in um s ing Al Can tur ac uf all n a H M

g rin u ct fa u an M s ll tle Ha t o TB

a

di

ng

Ba

y

+ 0.10

ng di l o sH k uc Tr

+ 0.20

g kin r Pa

t Lo

m 20

re St

et E2

Green Area

+ 0.20

E3

_Ground Floor Plan

_1:750

Obai Hasab Elrasoul Fifth Year Soft Drinks Factory _ Stage 5 _ 23/12/2012

2


organizer

Conveyer Buffer Area

Preparation: Shower, rinsing and Drying

Filling Hall Finished Cans, Glass and P.E.T Bottles Storage

Ov er

Pallets Lift

he

Traffic Control Units

n Co ts lle Pa tem ad Sys

Glass Bottles Manufacturing and Recycling

Automated Pallet System

ve

Palletizers

ye

Helical Conveyers

Packaging

r

Aluminum Cans Filling And Capping

Buffer Area before Palletizing

Glass Bottles Filling And Capping

P.E.T Bottles Filling And Capping

Depalletizer

+ 0.20

Syrup Preparation

Fridge

+ 0.20

Quality Control

+ 0.10

Ware House Neutral Temperature Storage

Fork Lifts Maneuvering Area

+ 0.20

Hydraulic levelers Loading Dock Dock For Side Loading Distribution Trucks

+ 0.10

Ready Product + 0.20

Automated Pallet System + 0.10

+ 0.20

Palletizer and Depalletizer

Arrived Pallets Temporary Holding area Pallet Feeding Necking and Packaging Depalletizer

+ 0.20

Loading

Aluminum Cans

P.E.T Bottles

Painting Press Shop

Organizer Tubes and Finished Bottles Palletizers Tube Molder

buffer Area

Pre-palletizing Helical Conveyer Packaging

_Ground Floor Plan

_1:750

Obai Hasab Elrasoul Fifth Year Soft Drinks Factory _ Stage 5 _ 23/12/2012

3


+ 20.00 + 15.00

+ 10.00 + 00.00

Elevation E1 _ 1:750

+ 20.00 + 15.00

+ 10.00 + 00.00

Elevation E2 _ 1:750

_Elevations

_1:750

Obai Hasab Elrasoul Fifth Year Soft Drinks Factory _ Stage 5 _ 23/12/2012

4


+ 20.00 + 15.00

+ 10.00 + 00.00

Elevation E3 _ 1:750

+ 20.00 + 15.00

+ 10.00 + 00.00

Elevation E4 _ 1:750

_Elevations

_1:750

Obai Hasab Elrasoul Fifth Year Soft Drinks Factory _ Stage 5 _ 23/12/2012

5


D1

+ 20.00 + 15.00

+ 10.00 + 00.00

2.515

0 00 2.

1.974

Section A-A _ 1:750

1.974

HOT WATER TANK:

1.974

CONDENSOR: Cools the hot Ammonia and turns it into liquid to be ready for evaporation.

SOLAR COLLECTORS:

Ambient Light 0 00 2.

Unique Fresnel Type Solar Thermal Collectors to Concentrate Sun Radiation In The Thermal Oil In the Evacuated Tube 30% less Expensive than the Parabolic Type.

Sun Rays Concentrated on the Mirror on the other Side Which Then Reflects them to the Tube To heat the Oil

Located above the hot oil tank to allow hot water to be continuously heated by convection without pumps.

Air outlet

CHIMNEY:

EVAPORATOR:

Integrated into the mesh surrounding the stairwell to not attract attention, it helps extract hot air by having its outlet high above the ground.

Expand extracted ammonia to achieve the cooling effect

ABSORBER: Contains water that absorbs the Ammonia and transfers it to the generator

AMMONIA GENERATOR:

Skylight:

Heats the water/ammonia solution to evaporate the ammonia

2.515

allways shaded by the concentrator's lens and only admits ambient light.

Light Duct

HEATED OIL TANK: An insulated cistern containing oil as a heat transfer and storage fluid. Copper tubes circulate inside it for exchanging heat between it and the compartments that require heat.

ROOM SPACE:

Mirrors Acrylic Diffuser 1.974

Filling Hall Space Now Illuminated all day

Minimum insolation is achieved by having two insulated concrete walls on the sides facing the sun and from above by the roof garden.

SOLAR HEAT COLLECTOR:

HEAT EXCHANGER: Fresnel Lens

3D Partial View of the Concentrator

Mirror

Shows the configuration of the sun tracking fresnel thermal collector and how it acts as shading device for the light duct

To provide proper air renewal, air is extracted still cold, so it's passed through this heat exchanger with the incoming air to pre-cool it before entering the chilled coils, which lightens the load for refregeration which increases the efficiency of the whole system.

COMPOST COMPARTMENT: Transforms human excreta into usable amendment for soil outside air inlet covered with an electro-static air filter

CHILLED COILS: Air coming from the heat recovery passes through it to complete the air cooling action.

EARTH:

Curved Glass Panel located in the area

Used for pre-cooling the air before entering the system, the effect is maximized because it's a damp soil because of being near the river, also because the segment needed for cooling is shaded by the units suspended above

which is shaded

with the lens for the whole day, curved to

allow for the movement of the device throughout the day Mirrors tunnel the ambient light from the sky until it reaches the diffuser (yellow) to be distributed all over the hall, thus full natural lighting without the heat.

UNDERGROUND HEAT EXCHANGER Air coming from the heat recovery passes through it to complete the air cooling action.

Detail 01 : Fresnel Solar Thermal Collectors _ 1:100

_Sections

Copper channels cover with vacuum glass tube for maximum heat gain and insulation to achieve least heat loss.

_1:750

Air Refrigeration Diagram - Zero Energy Cooling and Ventilation Obai Hasab Elrasoul Fifth Year Soft Drinks Factory _ Stage 5 _ 23/12/2012

6


Perspective _ Bird Eye View

Fresnel Solar Thermal Collectors On The Roof Of The Filling Hall

_Views

Obai Hasab Elrasoul Fifth Year Soft Drinks Factory _ Stage 5 _ 23/12/2012

7


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.