Saurer Era Technical Data Machine types
Pentacut
automatic embroidering position selector with thread cutting device
Options:
• Universal roller cloth system FastSpan, suitable to all common roller cloths
Illustration
œrlikon saurer
Saurer Era
Specifications
Embroidery length
[yard] [m]
No. of embroidering positions
1.75 1.6 60
Machine length
[m]
4.20
Fabric shaft length
[m]
2.30
[t]
2.0
[1/min]
500
Net weight (approx.) Maximum speed 1)
1)
The speed depends on the article to be manufactured, the yarns used and the operating conditions.
Embroidery height 2)
[mm]
780
Machine height
maximum height operating height transport height
[m]
2.10 1.12 1.70
Room height
minimum
[m]
2.40
Machine width
net
[m]
1.42
2) Restriction for machines with thread cutting and roller cloths with longitudinal tension rods:
The thread cutting device can be used 10 cm above the lower longitudinal tension rod and higher.
Oerlikon Saurer Arbon Ltd. Textilstrasse 2 9320 Arbon, Switzerland Phone +41 71 447 51 11 Fax +41 71 447 54 11 www.saurer.oerlikontextile.com info@saurerarbon.com DS0.0023.E00 05/09 Subject to technical modifications
·
·
·
·
·
Saurer Era Technical Data General technical data
Smallest needle repeat: 4/4 french inch = 27.07 mm Lateral movement: max. 56/4 repeat = 400 mm Smallest stitch unit: 0.1 mm horizontally and vertically
Control system
Connections
Fabric shaft-Ø: without cloth: 92 mm; wound with fabric: max. 110 mm Spool sizes: Ø 50 x 85 mm Shuttles: Saurer "Silenzio"
Boring depth: 0 to 20 mm stepless (= max. Ø 4.2 mm with borer 12%)
Bobbin size: 43 0/-0.2 x 14.7 0/-0.2 mm
Operation: Color touch screen monitor; manual control unit
Data format: Standard Highlevel Code (SHC)
Thread monitor: OptiPoint (single embroidering position monitoring)
Data interface: LAN; USB; diskette
Electrical supply: 3 x 400 VAC +/- 10% + PE 50/60 Hz +/- 2% A transformer is needed for other voltages (option)! We recommend using an UPS for the entire company. Overvoltage protection in accordance with our specification is required.
Pre-fusing: 25 A time-delay 3 phases (supply wire gauge min. 4 x 6 mm2) If local regulations require the installation of RCCB's, use an RCCB with a sensitivity of 300 mA, selective, pulse-power stable and inverter proof. Compressed air (customer): Compressed air supply 7 to 10 bar
For further specifications refer to document DS0.0171.E00.
DS0.0023.E00 05/09
Subject to technical modifications