Passive House Plus (Sustainable Building) issue 28 IRL

Page 1

INSULATION | AIRTIGHTNESS | BUILDING SCIENCE | VENTILATION | GREEN MATERIALS

S U S TA I N A B L E B U I L D I N G

EXTENDING CREDIT

Galway cottage reimagined with passive extension

Issue 28 €4.75 IRISH EDITION

THE DEEPEST, GREENEST RETROFIT EVER? Cohousing

The answer to the housing crisis?

A1-rated

DLR social housing

Celtic turkey

A housing boom without houses?


2 | passivehouseplus.ie | Issue 26


WHAT DETERMINES

THE QUALITY OF WINDOWS? Windows are an extremely significant part of a home, affecting its many aspects – appearance, functionality, security, energy efficiency. They are often the first thing that catch the eye and determine your overall impression of the building. Here we explore what makes quality windows. MATERIAL There are several perceptions on the quality of the different materials used for windows. But it’s more about how the material is used that determines the quality of the final product. For PVC, high-grade profiles from top manufacturers like Veka or Aluplast should be considered. Interestingly, PVC is fully recyclable at end of life, so it can be considered the most eco-friendly. Steel reinforcements in all PVC windows & doors is absolutely necessary to ensure strength and stability. This creates extraordinary possibilities, like the Oknoplast PVC sliding doors reaching up to 6.5m in width. Timber is generally not very suitable for the Irish climate, where moisture is ever-present. While exposure can be reduced through Alu-clad externally, the timber may still be affected by water vapour in the air. It’s imperative for the timber to be well treated/protected in production, and maintained regularly throughout its lifetime. Aluminium offers the highest level of durability and structural ability. However, thermal brakes are extremely important to ensure acceptable insulation parameters.

TECHNICAL PARAMETERS The numbers that determine the performance of windows are very important indeed, but need to be seen in the right perspective – only when we put them together, we see the whole picture.

Solar Factor – too much emphasis is sometimes put on this parameter. While solar gain may be significant during a cold but sunny winter in south Germany, it will rarely have the same effect in the Irish climate.

DESIGN Good windows don’t have to be beautiful, but great ones do. After all, windows are installed for a lifetime so it’s very important to love the way they look. Their style should follow latest architectural trends, while colour choices should be abundant and exciting – ultimately, colour is a way of expressing the owner’s style. Thoughtful design makes a difference, such as that in the Oknoplast Pixel window system – maximising the amount of light entering the room but maintaining great U-values.

SECURITY This point is simple but very important. No window is impossible to break in through, but the resistance it gives can often make the difference between a successful and unsuccessful breakin. The number and positions of the locking points are worth looking at. Windows absolutely must be internally glazed – an externally glazed window is as secure as an open window, as unglazing is a very simple procedure.

FUNCTIONALITY

U-value tells us how much heat escapes through the window. It’s therefore crucial to know the calculated U-value of the entire window, not just the centre pane. Triple-glazing is the current standard for energy efficient buildings across Europe. With a second chamber of the insulating Argon gas, it’s roughly twice as efficient as double-glazing.

A window should do more than just fill the hole in the wall, open and close. While only gaining popularity in Ireland at the moment, Tilt & Turn windows are the standard across Europe. This is largely due to their superior technology and improved functionality. Tilt & Turn windows can also achieve significantly greater sizes due to the more advanced hinges. Tilt and microventilation functions are also useful for additional airflow.

Air-tightness determines how well-sealed the window is and affects its energy efficiency. Class 4 is the benchmark for Passive windows, but can be achieved by some high quality near-passive windows too.

FITTING

The water-tightness rating of a window tells us how well it prevents water ingress under pressure – an important factor to consider. Sound insulation is another property worth considering. We all appreciate a quiet house when we need one. Good windows can reduce noise by around 35dB, e.g. bringing down the noise level of a driving truck to that of a quiet conversation.

Fitting is arguably the most important part of the window sourcing process. Proper procedures should be in place, starting with a thorough site survey. Solid fixing of the window is essential – a minimum of 8 brackets per window is a reasonable requirement. Air-tight sealing of all openings with low-expansion foam is a European industry standard which should not cost extra. Taping around the windows further improves the airtightness of the building, and should be available from the window supplier.

ph+ | advertising feature | 3


Publishers

Temple Media Ltd PO Box 9688, Blackrock, Co. Dublin, Ireland t +353 (0)1 210 7513 | t +353 (0)1 210 7512 e info@passivehouseplus.ie www.passivehouseplus.ie

Editor

Jeff Colley jeff@passivehouseplus.ie

Deputy Editor

Lenny Antonelli lenny@passivehouseplus.ie

Reporter

John Hearne john@passivehouseplus.ie

Reporter

Kate de Selincourt kate@passivehouseplus.ie

Reporter

John Cradden cradden@passivehouseplus.ie

Reader Reponse / IT

Dudley Colley dudley@passivehouseplus.ie

Accounts

Oisin Hart oisin@passivehouseplus.ie

Art Director

Lauren Colley lauren@passivehouseplus.ie

Design

Aoife O’Hara aoife@evekudesign.com | evekudesign.com

Contributors

Ciarán Cuffe, Green Party councillor | Tim Martel, Optimal Retrofit | Marc O’Riain, doctor of architecture | Mel Reynolds, architect | Peter Rickaby, energy & sustainability consultant | David W Smith, journalist | Jason Walsh, journalist | Karl Woods, Green Design Build

editor’s letter H

alf a lifetime ago, an errant friend of mine made a habit of arriving home after an evening’s over-exuberance, only to have the penny drop that he’d forgotten his house keys. He had no option other than to scale a back wall and contort his inebriated body through the narrowest of bathroom top light windows to get in. He repeated this trick more often than he’d care to remember - to the extent that he could remember. In the early years it was second nature to him: he was the proverbial whippet. But as the years went by, on the occasions - rare as they were becoming - when he had to repeat his contortionism, he told me it had become much trickier. The window seemed to be getting smaller. There may be more elegant metaphors for humanity’s climate crisis, but this one seems apposite. Carried away in our excesses, failing to plan ahead, we now find ourselves trying to contort our bloated selves to safety, with only a tiny - and in this case literally shrinking - window to contort ourselves through. If we fail, we’ll be exposed to whatever the elements throw at us. In our case, the shrinking window that faces us was once a proverbial bi-folding door. It’s over 30 years since James Hansen first brought global attention to global warming via providing evidence to the US Congress at a time when Washington paid more attention to little things like facts, evidence & the considered theories and analyses of its own experts. It’s over 21 years since the international community agreed to control and cut emissions under the Kyoto Protocol. And yet what have we done? 2018 is on course to be a record-breaking year for CO2 emissions - a 2.7% increase on 2017,

ISSUE 28 and an incomprehensibly large total of circa 27 billion tones. Then there’s the slew of recent evidence of mass species extinction - some of it linked to climate change, or to other environmental destruction humanity has wrought on the world. Or the evidence that our own lifespans risk being cut short by a heady cocktail of toxic air & water, resistant strains of bacteria developing from overuse and misuse of antibiotics (including antibacterial products), the collapse of food chains, etc. But we must not despair. It is incumbent upon us to carefully consider the evidence and start making the changes we need to make - personally, within our communities and on a societal level - to rapidly effect change. The last few years seem to have been hijacked by populist lurches on either side of the Atlantic. And as all-consuming and worrying as the potential fallout of the likes of Brexit & Trump may be to this particular snowflake, I’m left with an abiding feeling that they’ll ultimately look like a distraction. That unless we act quickly & decisively, we may find we’re not so much rearranging the deckchairs on the Titanic, but voting to elect a new captain & officers for the sinking ship. I hope you find inspiration for the kinds of meaningful actions we can take to tackle our current existence-scale crisis from some of the extraordinary buildings published in this latest issue, and from the combination of client-drive, design & construction ingenuity, & material & technological innovation on display. Regards, The editor

Print

GPS Colour Graphics www.gpscolour.co.uk | +44 (0) 28 9070 2020

Cover

House in Kinvara, Miles Sampson Architects Photo by Kelvin Gillmor

Publisher’s circulation statement: 9,000 copies of Passive House Plus (Irish edition) are printed and distributed to the leading figures involved in sustainable building in Ireland including architects; consulting; m&e and building services engineers; developers; builders; energy auditors; renewable energy companies; environmental consultants; county, city and town councillors; key local authority personnel; and to newsagents nationwide via Easons. Disclaimer: The opinions expressed in Passive House Plus are those of the authors and do not necessarily reflect the views of the publishers.

ABC Certified Average Net Circulation of 7,343 for the period 01/07/17 to 30/06/18.

4 | passivehouseplus.ie | Issue 28

About

Passive House Plus is an official partner magazine of the International Passive House Association. Passive House Plus (Irish edition) is an official magazine of the Passive House Association of Ireland.


SO QUIET WE HAD TO SHOUT ABOUT IT Ultra Quiet Ecodan The NEW LOW NOISE Air Source Heat Pump • An 8 dB(A) drop in sound output • Dedicated ATW chassis • Market leading performance

Keep it quiet, visit ultraquietecodan.co.uk Contact sales.info@meir.mee.com or call 1890 326 326 www.mitsubishielectric.ie

Search #ultraquietecodan

ph+ | editor’s letter | 5


CONTENTS COVER STORY

10

32

44

08

COLUMN

A housing boom without the houses?

There was much talk of jobless recovery as economies picked up after the last global recession. Mel Reynolds detects signs of an analogous proposition in the Irish property market: a housing boom that may be close to peaking without much in the way of housebuilding to report.

WANT TO KNOW MORE? The digital version of this magazine includes access to exclusive galleries of architectural drawings. The digital magazine is available to subscribers on www.passive.ie

6 | passivehouseplus.ie | Issue 28

10

INTERNATIONAL

16

NEWS

24

DISPATCHES

28

COMMENT

This issue features the 28-storey Bolueta building in Bilbao, which is the tallest building in the world certified to the passive house standard, and a clothing factory in Sri Lanka that’s also the first passive house project in South Asia.

Heat pumps & mechanical ventilation becoming the norm for new Irish homes, Ballymun centre wins sustainability award, and better overheating models needed for buildings.

New studies are seeking to answer questions about how both spray foam insulation and materials containing formaldehyde can affect indoor air quality — and some early results are worrying.

In his latest piece on the evolution of low energy design, Dr Marc Ó Riain focuses on a postwar architectural movement that fused passive solar design with innovative materials, and Dr Peter Rickaby puts forward his vision for a genuinely sustainable office building.


54

32

66

76

CASE STUDIES Good mews story in Dun Laoghaire

An award-winning social housing development in South Dublin points to a sustainable way out of Ireland’s housing crisis.

44

54

66

COVER STORY: Holy trinity

76

Situated in a stunning location in the west of Ireland, between Galway Bay and the limestone hills of the Burren, this project provided a complex challenge in three parts: deep retrofit an old cottage into a yoga studio, reinvigorate its original extension, and build a new barrel roofed passivegrade extension — then make it all work together as one unified home and workspace.

The deepest, greenest retrofit ever?

With obsessive attention to preserving and restoring the original fabric of these two Victorian townhouses, and a commitment to shunning petrochemicals and using only natural materials, could this be the most wildly ambitious and sustainable passive retrofit ever undertaken in the UK?

Iconic London scheme pioneers ventilation-led retrofit

Hundreds of flats at the Thamesmead estate in southeast London were suffering from horrendous damp and mould. But an ambitious new project has aimed to fix these problems at their root, while demonstrating a fresh approach to making old social housing healthier and more comfortable for occupants.

84

A passive mews fit for a physio

This beautifully designed passive house showcases some of the very best in contemporary urban architecture, responding thoughtfully to its historic surroundings while making ultra-intelligent use of space to create an airy, warm and light-filled home on a small mews site in South London.

INSIGHT

86

Cohousing & co-living in the context of crisis

If Ireland is to stand any chance of solving its housing crisis, innovative approaches may prove essential. Dr Karl Woods of Green Design Build and Green Party councillor & urban planning lecturer Ciarán Cuffe explore the role that cohousing and co-living could play.

MARKETPLACE

Keep up with the latest developments from some of the leading companies in sustainable building, including new product innovations, project updates and more.

ph+ ph+ | international | contents | 7


A housing boom without the houses? There was much talk of jobless recovery as economies picked up after the last global recession. Mel Reynolds detects signs of an analogous proposition in the Irish property market: a housing boom that may be close to peaking without much in the way of housebuilding to report.

A

veteran builder once told me “development is like musical chairs; if you are standing when the music stops, you are finished”. This article will examine current housing trends in Co Dublin. The table shows indicators of new home activity from 2016 to the second quarter of 2018. Planning permissions The Central Statistics Office (CSO) publishes an array of detailed information on new housing including planning permission data. Since 2016 in Co Dublin, 16,590 new estate homes and 11,414 apartments have been granted planning permission, a total of 28,004 units. Levels are increasing, leading many to assume that “activity in the construction sector is clearly now ramping up aggressively.” Permissions are a valid but not reliable indicator of activity. For various reasons up to 40% of schemes never get built, the so-called ‘permissions gap’. Completions and sales are accurate supply and demand metrics. CSO ‘derived ESB’ completions The CSO has recorded 8,186 new homes and 3,327 apartments completed in Co Dublin since 2016, a total of 11,513 dwellings. Just 41% of planning permissions granted have been built in the past two and a half years and 27% of new estate homes and 60% of apartments completed in this period remain unsold. ‘Overhang’ stock is increasing year-on-year. Completion figures are 27% greater than BERs issued and may still be slightly overstated. In 30 months, four Dublin local authorities have issued final BERs for 9,063 new dwellings. BERs are required by law for all new homes prior to occupation, sale or letting. This difference suggests illegal conversions and long-term vacant homes held by lenders as a result of arrears resolution, so-called ‘ghost’ arrears units, may be included. According to the Central Bank there are 3,000 homes vacant for more than three years in the latter category. New owners or tenants will need to apply for a new meter number (MPRN) on re-occupation, resulting in these existing homes being incorrectly counted as new homes. Social housing activity is at very low levels. Local authorities and approved housing bodies completed just 153 new social homes in the first half of this year in Co Dublin. New home sales The CSO also records residential sales,

8 | passivehouseplus.ie | Issue 28

Summary table of Permissions, Completions and Sales in Co.Dublin (Source: SEAI + CSO) Permissions, Completions & Sales in Co Dublin : 2016 - 2018 Q1 + 2 Permissions

CSO Completion

Apartments

2016

3,141

842

383

Houses

3,357

2,489

1,891

Subtotal 2017

Sales

6,498

3,331

2,274

Permissions

CSO Completion

Sales

Apartments

4,062

1,789

566

Houses

2,365

3,495

2,764

6,427

5,284

3,330

2018 Q1+2

Permissions

CSO Completion

Sales

Apartments

4,211

696

355

10,868

2,202

1,362

Subtotal

Houses Subtotal

14,079

2,898

1,717

TOTALS

28,004

11,513

7,321

whether new or second-hand, individual homes or block purchases by funds, as stamp duty transactions. ‘Build-to-let’ developments, where an owner builds-out a site and retains ownership, will not be captured, as no asset transfer has occurred. However, there has been little ‘built-to-let’ activity in the past three years. New dwelling sales appear flat compared to last year and residential lending has stalled. In Co Dublin 6,017 new homes and 1,304 apartments have been sold, a total of just 7,321 dwellings in two and a half years. This is significantly lower than permissions or completions and a fraction of even the most conservative demand projections. The state is very active in the new home sector, both building and buying. Since 2014 in Co Dublin, 5,721 new homes – more than 40% of all new sales – were dwellings funded by Nama. Out of the 3,330 new homes sold in Co Dublin last year, local authorities and approved housing bodies purchased 11.4%, 382 so-called ‘turnkey’ units. Most Nama funded homes are unaffordable and the state competes with ordinary buyers for new build purchased units. Is the music slowing? Planning permissions should not be used by officials as an indicator of building activity. In Co Dublin up to 60% of permissions were not built over the past thirty months. Of units completed, one-third remain unsold. More than half of new apartments remain as ‘overhang’ stock. Recent ‘bulk-sales’ of new schemes to institutional investors may be

symptomatic of lower than expected demand. Finance, affordability and consumer sentiment are contributing factors to sluggish sales. Land speculation, cost inflation, low margins and continued planning policy changes are head-winds stalling industry momentum. Commercial uses such as office, hotel, student/co-housing are more profitable than residential in many locations. Increasing height caps will not persuade developers to build expensive high-density schemes that are difficult to sell. Issues remain with how Department of Housing officials present housing activity. In Co Dublin in thirty months from 2016 to Q2 2018, new home sales are just one-quarter of the total of permissions granted. House-building is a cyclical industry and it is essential to have an informed view to plan ahead. Other than cash-rich private equity funds or Nama, few have the capacity to carry built schemes unsold for prolonged periods. The builder also said, “no-one knows when the music is going to stop”. n

A fully referenced version of this article is online at www.passivehouseplus.ie Mel Reynolds is a registered architect with more than 25 years of experience in project management, conservation, urban design and developer-led housing. He is also a certified passive house designer.


Find out more hi-thermlintels.com

We’ve cracked it...

The low cost solution for reduced carbon emissions

Available from

WINNER! Product of the Year ph+ | column | 9

Irish Construction Industry Awards 2018


WANT TO KNOW MORE? The digital version of this magazine includes access to exclusive galleries of architectural drawings.

Photos: VArquitectos

08/03/2016

The digital magazine is available to subscribers on www.passive.ie

10 | passivehouseplus.ie | Issue 28


INTERNATIONAL A SELECTION OF PASSIVE & ECO BUILDS FROM AROUND THE WORLD

BOLUETA BUILDING, BILBAO, SPAIN

A

t 28 storeys tall and rising to a height of 88 metres, the Bolueta building in the Spanish city of Bilbao is now the tallest building in the world certified to the passive house standard. Developed by the Basque government’s own property development firm Visesa, it will soon be accompanied by a second 21-storey passive block, with the two buildings containing 361 social housing units. But the project had a rocky start. Back in 2012, architects VArquitectos won a competition to design the project. It was intended to be energy efficient from the get-go — but not necessarily passive house standard — and to draw heat from the local district heating network. But when the network supplier went bust, Visesa decided it needed an even more efficient building. VArquitectos and energy consultant Energiehaus started to examine the possibility of adopting the passive house standard, and found that the optimum geometry, low surface-to-volume ratio and the warm local climate all made it ideally suited. So, the team set about beefing up the energy efficiency spec. The finished building is constructed from steel-and-masonry, with mineral wool

insulation to both the outside (10cm) and inside (5cm). The designers swapped out the double glazing for triple glazing when re-designing the project. and introduced heat recovery ventilation. All units in the building were made individually airtight and achieved an air test result of between 0.28 and 0.35 air changes per hour — about half the maximum 0.6 allowed under the passive house standard, an exceptional achievement. The shining external finish, meanwhile, is a ventilated aluminium cladding. “The black colour symbolises the industrial past of the city,” says architect Germán Velázquez of the practice VArquitectos. “It is a tribute to the two-and-a-half century old heavily coal-based industry.” The second tower, meanwhile will be grey in colour to allude to the steel industry once prominent in the city. The architects estimate that all the improvements over the initial project increased the capital cost of the project by about 3%, while cutting energy bills in half and improving comfort and air quality. “Now that Bolueta is complete, there are no excuses anymore,” says Velázquez. “It is possible to realise such a project in Bolueta, and it is just as possible to realise one almost anywhere.”

ph+ | international | 11


12 | passivehouseplus.ie | Issue 28


Photos: Jordan Parnass Digital Architecture

STAR GARMENT INNOVATION CENTRE, SRI LANKA

T

his new clothing factory in Colombo, Sri Lanka is the first passive house project in South Asia and, located just above the equator, it posed vastly different climatic challenges than your average European passive house designer is used to — think tropical monsoons, year-round heat, and extremely high relative humidity. Developed by the Star Garment Group — a global apparel sourcing, design and manufacturing firm — the building serves as the company’s new product development centre, a hub for design, material sourcing, pattern making and sowing. And according to its designers, Jordan Parnass Digital Architecture, it “sets a new high bar for sustainability, energy efficiency and worker comfort” in the garment industry. Rather than build entirely from scratch, the project team opted to retrofit an old factory on the site, stripping it back down to the original steel frame and concrete slab,

thus reusing elements that would otherwise have significantly increased a new building’s carbon footprint. The original steel frame was filled in with a new thermal envelope comprised of high performance curtain walling, externallyinsulated masonry and insulated metal roofing panels — all of it made airtight. Given its tropical location the building has zero heating load, but instead requires mechanical cooling and dehumidification. There are also strategically designed overhangs and external shading screens to help keep the sun out. The project was recently certified to the Enerphit standard, the Passive House Institute’s benchmark for retrofit projects. “By promoting the project’s goals and inspiring the local building industry, JPDA has sought to establish a clear path to both reducing global carbon emissions and putting an end to worker ‘sweatshop’ conditions,” say the architects.

ph+ | international | 13


Low u-value insulation at roof, exterior walls, and underside of cantilevered slab

PV panel for solar electricity and dehumidification Reflect solar heat

Reduce solar heat gain with roof eves and exterior shading device

Thermal bridge free Mechanical ventilation with more than 75% heat recovery

Underside of cantilevered slab is insulated for continuous thermal enclosure. Exterior columns are covered with insulation to reduce heat transfer into interior space. Insulation is extended few inches beyond the footing for thermal enclosure.

14 | passivehouseplus.ie | Issue 28

Airtight thermal envelope Low u-value insulation PV panels Exterior shading device


kingspaninsulation.ie kingspaninsulation.ie +353 (0) 42 979 5000 +353 (0) 42 979 5000

Shaping Shaping the the Future Future Built Built Environment Environment Pioneering Pioneering new new technologies technologies with with energy energy conservation conservation at at heart. heart.

Kingspan Kingspan offering offering the the widest widest range range of of insulation insulation products products and and solutions. solutions. Kingspan Optim-R is a vacuum insulated Kingspan Optim-R is a vacuum insulated panel which is an optimum performance panel which is aninsulation optimumsolution. performance next generation next generation insulation solution. Kingspan Optim-R achieves an Kingspan Optim-R achieves an outstanding low thermal conductivity, outstanding low thermal conductivity, with the thinnest possible solution to with the thinnest possible solution to insulation problems. insulation problems.

Kingspan Kooltherm Insulation is our Kingspan Kooltherm Insulation is our premium performance rigid phenolic premium rigidconductivities phenolic insulation performance with low thermal insulation with lowinthermal conductivities and can be used an extensive range and can be used in an extensive range of new and existing building applications. of new and existing building applications.

Kingspan Therma Insulation is our Kingspan Therma polyisocyanurate Insulation is our high performance high performance polyisocyanurate insulation which can also be used in an insulation which of can also beexisting used in an extensive range new and extensive range of new and existing building applications. building applications.

Kingspan Styrozone Insulation is a high Kingspan Styrozone Insulation is a high insulant performance rigid extruded polystyrene performance rigid the extruded designed to meet needspolystyrene of specialistinsulant projects designed to meet the needs of specialist projects which require a heavy duty robust insulation. which require a heavy duty robust insulation. Kingspan Styrozone Insulation is available in a Kingspan Insulationstrength is available in ato number ofStyrozone high compressive grades number of high compressive suit a range of service loads. strength grades to suit a range of service loads.

The Kingspan TEK Building System comprises The Kingspan TEK Building comprises of structural insulated panelsSystem (SIPs) with a high of structural insulated panels (SIPs) with a high performance fibre-free rigid urethane insulation performance fibre-free rigid urethane insulation core, sandwiched between two layers of core, sandwiched between layers of Oriented Strand Board type two 3 (OSB/3). Oriented Boardwalls type and 3 (OSB/3). It is used Strand to construct roofs, It is used to construct roofs, or and intermediate floorswalls usingand I-beams and intermediate floors using I-beams or open web joists. open web joists.

Kingspan Aerobord Insulation offers a wide Kingspan Aerobord Insulation offers a polystyrene wide range of high performance expanded range of high performance polystyrene insulation boards for floors, expanded walls and pitched insulation for in floors, walls andAerobord pitched roofs. Alsoboards available the Kingspan roofs. Also available in the Kingspan Aerobord Insulation are high performance platinum Insulation high performance platinum expanded are polystyrene beads suitable for expanded polystyrene beads suitable pumping into cavity wall constructionsfor and ph+and | international | 15 pumping intoFoundation cavity wall constructions an Insulated System. an Insulated Foundation System.


NEWS

Heat pumps & mechanical ventilation start to dominate new homes market

H

eat pumps were likely the dominant heating system in new Irish homes in 2017, and mechanical ventilation is on course to overtake natural ventilation in new homes this year, an analysis by Passive House Plus has revealed. The new projections also indicate that BERs will eventually be issued for approximately 13,400 new homes built in 2018, with another 3,000+ one-off homes failing to comply with the requirement to obtain BERs prior to occupancy. The analysis was done using SEAI’s National BER Research Tool, combined with estimates based on commencement notices for one-off houses from the Building Control Management System. By 22 November, 6,956 final BERs had been published for new homes built in 2018, compared to 5,080 BERs for 2017 homes published by the same date that year. The total for 2017 homes currently stands at 9,364 homes – a figure projected to increase by circa 400 once late BERs are published. The 2017 total includes only 588 one-off houses – namely homes listed as detached houses, where the BER was obtained for occupation by homeowner, rather than a sale. Circa 3,000 additional self builds are believed to be unaccounted for. The projections do not account for any impact that may arise if the state succeeds in driving up compliance rates in the self-build sector. Heating systems & renewables Of the homes built in 2017 with published final BERs – therefore excluding circa 3,000 one-off homes – heat pumps have 36.6% market share, with gas boilers at 52.6%, oil boilers at 4.1%, CHP at 5.8% and LPG at 0.8%. Based on the assumption that the missing homes have the same heating systems as the 588 one-off homes with BERs in 2018 (detached houses where the BER was obtained for occupation by homeowner, rather than for a sale) – 70% of which had heat pumps – the figures change dramatically. Heat pumps at 44.7% would become the most common heating system, gas boilers would fall to 42.8%, with oil boilers recovering somewhat to 7.8%, and CHP down at 4.4%. Solar thermal systems were installed in 9.9% of new homes to date in 2018, down from 10.8% in 2017, continuing their declining market share in recent years. Unlike

16 | passivehouseplus.ie | Issue 28

0.6 2018 standing total

0.5

2017 standing total

0.4

2017 adjusted*

0.3 0.2 0.1 0.0

Mains gas

Electric (Heat pumps)

Heating oil

CHP

Bulk LPG

Heating System Market Share

*Adjusted 2017 figures include estimated heating system breakdown for circa 3,000 missing one-off houses.

heat pumps, solar thermal doesn’t fare much better in one-off houses with BERs, indicating that its market share would be unlikely to rise by more than a point or two if the missing one-off houses were included. Meanwhile the market share of solar PV arrays – typically in conjunction with gas boilers - has increased marginally from 51.3% in 2017 homes to 51.8% of 2018 homes to date. Mechanical ventilation A swing towards mechanical ventilation – and whole house extract ventilation in particular – is evident in the 2018 homes. Of the 6,956 new homes built so far in 2018 with final BERs, 24.6% include whole house extract ventilation – the category that includes the increasingly popular demand controlled mechanical extract ventilation systems. Heat recovery ventilation is at 24.1%, while natural ventilation comes in at 50.2%, with positive input ventilation making up 01.1%. However, a markedly different picture emerges from the further 3,361 provisional BERs for homes being built in 2018, which lean disproportionately towards mechanical ventilation. Assuming this cohort of homes is built as per the specs in their provisional ratings, natural ventilation falls to 47.3%, heat recovery ventilation falls to 22.4% and whole house extract ventilation rises to 29.5%. U-values U-values for walls are on course to marginally improve on last year – from 0.177 in 2017 to 0.173 in 2018, though that may change once late BERs for 2018 homes are published. Excluding BERs with stated U-values of zero – as the Deap software assumes

zero heat loss respectively for floors and ceilings of dwellings with heated spaces above or beneath – the average roof is on course to marginally improve from 0.131 last year to 0.130 in 2018, with the average floor weakening from 0.137 in 2017 to 0.140 in 2018. Windows meanwhile have also marginally declined from an average of 1.20 in 2017 to 1.21 in 2018, with doors marginally improving from 1.48 in 2017 to 1.46 in 2018. Thermal bridging 88.3% of new homes in 2018 used a thermal bridging factor (or Y-value) of 0.08 or worse. A value of 0.08 indicates the use of the Acceptable Construction Details, and a value of 0.15 is a default when neither ACDs or calculated Y-values have been used. The homes that used a value below 0.08 averaged a score of 0.0529. Y-values are added to the U-values of opaque elements in Deap. Therefore, a wall U-value of 0.18 effectively rises to 0.26 if a Y-value of 0.08 is added. The effect on calculated heat loss is profound. The 2018 homes with calculated Y-values saw their U-values rise to 0.22 (wall), 0.19 (roof) and 0.17 (floor), whereas homes with a Y-value of 0.08 saw their wall, roof and floor U-values rise to 0.25 (wall) 0.21 (roof) and 0.20 (floor) respectively, and the 10% that used a Y-value of 0.15 saw U-values rise to 0.32 (wall) and 0.26 (roof and floor). Meanwhile average airtightness test results are on course to statistically tie – scoring an average q50 of 2.83 m3/hr/m2 at 50 Pa in 2018 and 2.82 in 2017, once those homes with a default airtightness q50 of 7 have been excluded. •


New Europe-wide boost for energy efficient mortgages Energy efficient properties less likely to default, research finds Words by Lenny Antonelli

T

he Energy Efficient Mortgages (EEM) Initiative has unveiled a new definition for energy efficient mortgages, which is intended to make it easier for the 41 participating lending institutions – including the likes of Barclays & KBC – to offer more attractive finance terms to those buying energy efficient properties. It comes just as two Bank of England economists have published a statistical analysis demonstrating that energy efficient properties are less likely to end up in mortgage arrears. The provision of so called ‘energy efficient mortgages’ that incentivise homeowners to buy or build low energy homes, or retrofit to low energy standards, is seen as an essential driver in pushing the property market towards sustainability. However, to date few such mortgages have been available to consumers. Notable exceptions in the UK include Ecology Building Society’s C Change mortgages, which offer preferential interest rates for homes meeting higher energy performance standards, such as passive house, and the Barclays Green Home Mortgage, which offers better lending terms linked to the EPC score of the house. The new EEM definition says that energy efficient mortgages are mortgages that provide finance for buildings where there is evidence of “energy performance which meets or exceeds relevant market best practice standards in line with current EU legislative requirements” or “an improvement in energy performance of at least 30%”, for retrofits. It adds: “This evidence should be provided by way of a recent EPC [energy performance certificate] rating or score”. At the end of 2017, the 41 institutions participating in the EEM held 55% of mortgages in the EU, meaning the new move could potentially have significant influence in the market. Commenting on the new definition, Gerassimos Thomas, the European Commission deputy director-general for energy, said that move would “facilitate the implementation of energy efficiency investments where they are most needed,

in the buildings sector” and serve as “an important step, opening the way for a quick roll-out of energy efficiency mortgages.” However, there is some concern that EPCs or BERs remain an unreliable measure of the energy performance of highly efficient properties, such as passive houses, due to the way they are calculated. For example, the Old Holloway passive house featured on the cover of Passive House Plus issue 27, a certified passive house which has zero space heating bills, only has an EPC rating of C, suggesting that some passive homes with practically no energy bills could struggle to qualify for better financing terms. Lower default risk Meanwhile, a statistical analysis published by two Bank of England economists, Benjamin Guin and Perttu Korhonen, has concluded that mortgages on energy efficient properties are less likely to end up in arrears. The analysis, published on the bank’s policy blog www. bankunderground.co.uk, examined a sample of 1.8 million properties for which loan performance data and energy performance certificates (EPCs) were available. The authors classified homes with an A, B, or C energy rating as “high energy efficiency”, and homes with an E, F, or G ratings as “low energy efficiency”. The authors’ initial analysis found that 0.93% of the energy-efficient properties were in payment arrears, compared to 1.14% of the energy inefficient properties — a statistically significant difference of 0.21%. “Two mechanisms could be driving this difference,” the authors wrote. “On the one hand, energy bills are lower on energy-efficient properties. Savings on energy bills could lead to lower arrears rates (‘energy savings affect’). Alternatively, high-income borrowers could be more likely to take out mortgages against energy-efficient properties. Such borrowers may fall into arrears less frequently (‘income selection effect’).”

But the authors ultimately ruled out the ‘income selection effect’ by comparing mortgage arrears of borrowers with similar income, and found that the difference remained similar between energy efficient and inefficient properties. They went on to perform tests to control for the possibility that various other factors could be causing the difference, and did find that when they controlled for the year that the mortgage originated and the EPC inspection was performed, the difference in payment arears decreased to 0.10% — but this was still statistically significant. “We conclude that the energy efficiency of a property is a relevant predictor of mortgage risk,” the authors wrote. For more on the Energy Efficient Mortgages Initiative see eemap. energyefficientmortgages.eu. •

Photo by IAEA

(above) Gerassimos Thomas, EU deputy director-general for energy, welcomed the new definition for energy efficient mortgages.

ph+ | news | 17


Performance gap much smaller for passive homes, research finds Dwellings built to passive standard consistently perform much closer to design targets, authors conclude. Words by Kate de Selincourt

A

detailed study of test results from building structure, there could have been co-heating tests. Most of the passive almost 200 low energy homes in implications for indoor air quality. Air dwellings underperformed slightly – these the UK suggests that while gaps quality measurements were not within the generally showed an ‘overspend’ of about between designed and real-world energy scope of this meta-study, though they will 4.5 W/K (an overshoot of around 10%). performance are ubiquitous, these gaps be the subject of future research by the Whole house heat loss in the non-passive are much smaller in dwellings built to the same team. dwellings was much more variable, with passive house standard. Overall there was barely any relationship some even doing better than designed. Professor Rajat Gupta and Dr Alkis between design and delivered air However of those non-passive dwellings Kotopouleases at Oxford Brookes permeability for non-passive dwellings, which underperformed, the gap was much University, analysed data from the UK’s which suggests that “design air bigger than with the passive dwellings – ten National Building Performance Evaluation permeability” means nothing in practice, times as big in fact, at an average of 42 W/K, programme (begun in 2010 by the then unless the result is tested and enforced, as it a 30-50% overshoot for many. Technology Strategy Board). The 188 is on certified passive house builds. As the authors wrote: “the magnitude of homes, comprising 50 passive and 138 Meanwhile, just over half the passive underperformance was much less in PH non-passive dwellings, dwellings ... a comparison were built with a range of between the non PH construction systems and and PH developments to various performance [using thermal imaging] targets. revealed a significantly The team analysed lower frequency of the results of air leakage defects amongst the tests, in-situ U-value latter, highlighting the measurements of walls importance of attention and roofs, and whole to detail that is integral in house heat loss. a PH approach.” The biggest set of data “Despite the small was for air permeability. sample of PH dwellings The non-passive homes with a complete set of had a range of air fabric performance data, permeability targets, it is evident that PH from 1.5 m3/h/m2 (at 50 dwellings perform well Pascals of pressure, normal test conditions) dwellings also showed airtightness across all the three in-situ tests, indicating right up 10 m3/h/m2 (the legal maximum). performance gaps, with worse fabric the robustness of the PH standard.” But the actual results did not have much permeability than target, but in these The study also identified a difference relationship to the targets, with nearly instances the average gap was only 0.5 between masonry and timber construction. half of the homes being leakier than the m3/h/m2, 75% less of a gap than in the “The fabric performance gap was non-passive homes. The widest gap was 1.3 targets, which were often unambitious in consistently larger for dwellings with m3/h/m2 among passive dwellings, and 6.3 the first place. The average air permeability masonry construction. Compared to their m3/h/m2 among non-passive dwellings. ‘overshoot’ was almost 2 m3/h/m2. timber counterpart, masonry builds were Most of the homes were fitted with found to be leakier and have higher external U-values & heat loss mechanical ventilation with heat recovery wall thermal transmittance and whole In-situ U-values were measured in 20 (MVHR) systems, which would not have house heat loss,” the authors wrote. of the dwellings and these too showed been performing efficiently in the 81% of Although numbers were small, masonry regular discrepancies between targets non-passive homes with leakiness worse builds had a 20 W/K higher heat loss and measured results, under-performing than 3.0 m3/h/m2, the recommended air coefficient on average than the timberpermeability limit for installing MVHR, the in three quarters of those measured. The framed dwellings, which averaged very little authors point out. passive house walls measured on average performance gap. UNPARALLELED CHOICE OF PASSIVE CERTIFIED PRODUCTS – OUTWARD OPENING, INWARD OPENING, UPVC, ALUMINIUM, ALUCLAD A small number of homes used 0.03 W/m2K higher than target, with But the results for passive dwellings non-passive dwellings averaging 0.07AS W/ LOW mechanical extract or ‘natural’ ventilation. showed smaller deviations from GROUND BREAKING U-VALUES FROM AS much 0.47W/M²K m2K higher. In ten cases, the wall U-value Their permeability targets averaged at 8.5 design targets for both masonry and timber was worse than that allowed in the building m3/h/m2, but on average these homes construction, “indicating that the quality actually had better infiltration rates than regulations. of detailing and workmanship is more designed: for in the ‘naturally ventilated’ Roof U-values also missed their targets, important than the type of construction,” • homes it was 40% better on average (5 with passive house roofs measuring T. 064 7751151 the authors wrote. E. info@munsterjoinery.ie m3/h/m2). 44% worse than target on average, and While this could offer energy and comfort non-passive dwellings 71% worse. (above) Designed and measured air advantages, if the ventilation strategy was For 29 of the dwellings the whole house permeability by ventilation strategy for 50 passive and 138 non-passive dwellings. dependent on air infiltration through the heat loss had also been measured, via

SHOWROOMS: CORK, DUBLIN, GALWAY & BELFAST

www.munsterjoinery.ie

WINDOWS & DOORS

18 | passivehouseplus.ie | Issue 28


Pictured at Better Homes 2018 are (left to right): Minister of State for Housing Damian English, Dr Gráinne McGill of the MEARU research unit, Pat Barry of the Irish Green Building Council, and Matthew Barker of the BRE.

Irish building industry foresees imminent green shift

F

ifty-four percent of Irish organisations participating in the World Green Building Trends 2018 SmartMarket Report expect their projects to be green by 2021 — well above the global average of 47%. “The number of green buildings has increased significantly in Ireland over the last five years,” said Pat Barry, CEO of the Irish Green Building Council (IGBC). “There are substantial social and economic impacts of going green. These buildings create a more productive workplace for occupants and can help with mitigation of climate change. Green buildings also see benefits for corporate reputation and the building itself has lower volatility in market value.”
 Published by Dodge Data & Analytics, the new industry report shows that client demand is the most important trigger for new green building activity in Ireland, selected by 71% of respondents, more than double the global average. Environmental regulations are the other notable trigger in this country.
 In spite of these encouraging results, the lack of educated green building professionals was identified as a key obstacle to more green building by nearly half of Irish participants. “Construction professionals have substantial responsibility in promoting a greener built environment. The sustainability skills of the Irish construction sector must be updated if Ireland is to achieve its climate targets,” said Pat Barry. “As part of its training programme, the IGBC recently launched a nearly zero energy building (nZEB) webinar. We also work in close cooperation with other construction institutes to better incentivise professionals to upskill in the area. Yet, we cannot achieve anything without strong

governmental support and leadership.” The World Green Building Trends 2018 SmartMarket Report indicates that the international market for green construction projects has grown significantly in the last 10 years and demand for green building activity is poised to grow globally. Healthier buildings also emerged as a top green priority in the study. For example, the top social drivers for green buildings included improved occupant health and well-being. Participants in the survey included over 2,000 architects, engineers, contractors, owners, specialists/consultants and investors from 86 countries. The survey used a definition of green building that included, at a minimum: energy, water and general resource efficiency; waste reduction and recycling, and good indoor environmental and air quality. It also specified in its definition that many green buildings include: the use of renewable energy; materials that are non-toxic, ethical and sustainable; consideration of the quality of life of occupants, and a design that adapts to a changing environment. For the full report visit www.igbc.ie.
 Air quality & climate change big risks for housing, IGBC event hears Meanwhile, indoor air pollution was extensively discussed at the IGBC’s ‘Better Homes’ conference in Dublin on 8 November, with attendees hearing that it represents a major health risk factor for Ireland’s new home building programme. “Irish people spend 90% of their time indoors. Poor ventilation can have significant implications on health,” read a statement released by the IGBC in conjunction with the event. “As new

homes become more insulated and airtight, greater focus is needed on the management of ventilation.” One of the speakers at the conference, Dr Gráinne McGill of the Glasgow-based MEARU research unit, said: “Poor indoor air quality in housing can be increasingly traced to poor ventilation. As our homes become more airtight, less dependence can be placed on natural infiltration. Adequate ventilation systems are now critical.” IGBC CEO Pat Barry emphasised the need to give consumers more information on the quality of housing they are buying. "We are committed to enabling home buyers to make more informed choices,” he said. “Our Home Performance Index certification scheme provides a single label for quality and sustainability. It indicates to home buyers that a house has been built to consider impacts on health and is climate change resilient.” The conference also heard about key risks for Irish homes brought by climate change, including flooding and overheating. “To minimise the health impacts of climate change, every home must be planned, designed and built to be sustainable,” said Dr Ina Kelly, a public health consultant with the HSE. “The particular vulnerability of the very young, the sick and the very old must be fully taken into account.” Another speaker at the event, Matthew Barker, resilience and risk expert with building science centre BRE, added: “The construction industry needs to be pro-active in its response to climate change. Simple design changes can reduce climate related risks such as flooding. Resilience must be considered before an event not as a response to it.” •

ph+ | news | 19


Coming early 2019

THE EVOLUTION OF CONTROL NEW HEAT RECOVERY VENTILATION BY AERECO www.aereco.ie 20 | passivehouseplus.ie | Issue 28


Rediscovery Centre wins sustainable energy award

(above) Roger Warburton, operations manager at the Rediscovery Centre, picking up the Buildings Award at the SEAI Sustainable Energy Awards from SEAI chairperson Julie O’Neill.

T

he Rediscovery Centre in Ballymun picked up the Buildings Award at the 2018 SEAI Sustainable Energy Awards, which were held at the Mansion House, Dublin, on 25 October. The awards recognise excellence in energy management in business, communities and public sector organisations. Profiled in issue 22 of Passive House Plus, the Rediscovery Centre is “a creative space in Ballymun connecting people, ideas and resources for greener living”, and occupies a retrofitted old boiler house that was originally set for demolition. As well as a highly insulated and airtight building envelope, the building features a suite of sustainable features, including an air source heat pump, composting toilets, rainwater harvesting, LED lighting, solar panels (PV & thermal), a green roof and living wall, on-site grey water recycling, landscaping to encourage biodiversity, and new walls of hempcrete and timber frame construction, as well as a strong emphasis on natural materials throughout. Indoor air quality monitoring is also now underway at the centre. Throughout the project, opportunities for reuse of materials were given preference. For example, the outside of the building was finished using recycled brick and cladded with old shutters from the original boiler house. Interior glass and some insulation were sourced from leftover materials from the wider local area regeneration. Where new materials were needed to complete the building, they were sourced as locally as possible. Commenting on the awards, SEAI chief executive Jim Gannon said: “The SEAI Energy Awards celebrate the absolute best of Ireland’s sustainable energy achievements. They are a vivid demonstration of how Irish business, communities and public organisations are pushing the boundaries in energy efficiency and the switch to clean energy. The 80 plus entrants in this year’s awards have made energy savings of €38 million and they are responsible for €30 million in energy generated from renewables, which is equivalent to powering 166,000 homes.” He continued: “As the realities of climate change becoming clearer to us all, it is particularly important to highlight what work is being done by energy leaders across the country. The commitment and dedication of the finalists should be a huge inspiration to us all." Other winners of the awards included: Gurteen College, Tipperary; EirGrid; MPOWER, Dublin; The Aut Even Hospital, Kilkenny; Sligo University Hospital; Aran Islands Community Energy Cooperative, Galway; Lidl Ireland and Northern Ireland GmbH; and Wyeth Nutrition, Limerick. For full details on all winning projects, visit www.seai.ie. •

ISH fair returns to Frankfurt in March 2019

I

SH, the world’s leading trade fair focused on building services, energy, and water, returns to Messe Frankfurt from 11 to 15 March 2019. Over 2,400 exhibitors, including market leaders and technological pioneers from Germany and abroad, will be showcasing their wares, with many launching new product innovations for the first time at the show. ISH 2019 will incorporate the newly constructed Hall 12 at the Messe Frankfurt exhibition centre, which along with Hall 11 will provide a dedicated space to showcase the latest innovations in heating technology. “With the new hall layout, ISH Energy 2019 will focus on heating systems that combine a high degree of efficiency with the greater use of renewable energies," said Wolfgang Marz, president and chief executive of Messe Frankfurt. "This also includes new themes such as generating electricity via photovoltaic systems for use in the own home, in combination with a heat pump, a thermal or battery storage facility and a central digital energy manager.” Meanwhile refrigeration, air-conditioning and ventilation will be located in Hall 8, while home automation, energy management and control technology will be located in Halls 10.2 and 10.3. The ISH Water section, meanwhile, will be focused on sustainable water and wastewater technologies, intelligent water management systems, and the latest in ultra-modern bathroom design. For more information see www.ish.messefrankfurt.com. •

(below) ISH at Messe Frankfurt in 2016.

ph+ | news | 21


(above) A still from an animation by Greenlite on the thermal behaviour of the University of Nottingham’s Research Acceleration and Demonstration building, showing room temperatures over the course of the hottest simulated day; (above right) Richard Tibenham of Greenlite Energy Assessors.

Buildings need better overheating models to guarantee future comfort

B

uilding designers need to undertake much deeper analyses of overheating risks, and do so under future climate change scenarios, in order to ensure their buildings can adapt and remain comfortable for occupants in a warming world. That’s according to Richard Tibenham of Greenlite Energy Assessors, energy and thermal comfort consultants, who also called for a much more integrated design approach between architects, engineers and contractors to ensure long term comfort for building occupants. “The magnitude, duration and frequency of heatwave conditions is increasing across Europe as a consequence of climate change, thus the demand for sufficient safeguards is becoming more pertinent,” Tibenham said. “Low energy buildings are at an increased risk of overheating due to inherent design characteristics such as increased levels of airtightness and insulation. Ill-conceived glazing quotas, glazing orientation and shading strategies can present overheating risks, which can be extreme at times.” “There is no requirement under the current UK building regulations to assess overheating risks, and this is manifesting in a moderate number of buildings incurring overheating problems or excessive mechanical cooling loads.” “Predictive weather data combined with accurate thermal modelling suggests that the vast majority of buildings are woefully unprepared for a changing climate.” Tibenham said that the quality of architecture in response to overheating

22 | passivehouseplus.ie | Issue 28

risks varies significantly, with some schemes taking sensible design measures from the early design stages, whilst other schemes take very little consideration of overheating risks at all. Too often, he said, schemes rely on low-g glazing as a cover-all response to excessive glazing quotas, however this can in turn increase winter time heating loads. He said that in the event that an overheating analysis is undertaken, these often set the bar at CIBSE TM52 compliance using Design Summer Year (DSY) 2005 weather data. “From my own works, whilst these buildings may pass the code when assessed using DSY05 data, they very often fail when tested against 2030 weather data, let alone 2050 or 2080.” “I suspect the outcome will be an increase in the amount of retro-fitted air conditioning systems, which is obviously undesirable when attempting to decarbonise the grid at the same time. This could be avoided however if a longer term stance to summertime comfort were adopted and buildings were tested under the weather conditions likely to be experienced during their operational lifetime.” Dynamic thermal models Tibenham added: “A dynamic thermal model or DTM can be helpful for any building, and can often turn up some useful and highly detailed design data that would otherwise go unacknowledged. With respect to passive house schemes, a DTM can be incredibly useful in determining localised indoor environments, since the PHPP deals with the building as a whole, rather than as

a cluster of interrelated environments.” “For larger commercial buildings in particular, this level of analysis can be highly valuable in avoiding potential localised risks. If sufficiently detailed, the models can also be very useful in assessing the behaviour of complex HVAC networks, and the impact of various control strategies and set-points.” Tibenham said that undertaking a reliable DTM provides a looking glass into the behaviour of a building, and allows the trends and behaviour of various building physics phenomena to be better understood. This understanding, he said, can be fed back into the design cycle and used to better inform future buildings. “From my experience, building services engineers tend to read the reports, but understandably focus on black and white measurable performance objectives such as Part L outcomes and BREEAM. Many main contractors and architects neither read or understand the reports, leaving the contractual responsibility for thermal comfort solely with the building services engineer. This results in the same problems re-occurring, with the building form and fabric presenting problems which require a HVAC response.” “I am looking to engage with architects and contractors who wish to put the thermal and energy performance of the building at the core of the design process, with the building fabric and building services operating as an integrated system, rather than as separate entities. Early engagement is key to achieving optimum outcomes.” For more information see www. greenliteea.co.uk. •


A Heat Pump that’s easy to live with

DeDietrich Alezio Easylife Heat Pump An air/water heat pump that gives you a quick return on your investment, a competitive price and user friendly functionalities. You dreamed about it, De Dietrich has created it. Discover Alezio Easylife, a compact, economic and environmentally friendly solution. Ideal for heating, cooling and the domestic hot water, in new build and renovation alike. Let’s face it, it’s in the air… for the taking!

www.origen.ie Tel: +353 1 419 1940 | Email: sales@origen.ie Address: Muirfield Drive, Naas Road, Dublin 12 Unit L, Furry Park Industrial Estate, Santry, Dublin 9 South Ring West Business Park, Tramore Road, Cork

ph+ | news | 23


NEW RESEARCH R A I S ES S PR AY F OA M H E A LT H Q U E ST I O N S

New studies are seeking to answer questions about how spray foam insulation, and materials containing formaldehyde, affect indoor air quality — and some of the early results are worrying.

Words by Kate de Selincourt

P

reliminary research into emissions from cured spray polyurethane foam (SPF) insulation suggests that potentially harmful substances may continue to be emitted from the insulation long after it is installed. One study found that the flame retardant TCPP appeared to be off-gassing from spray foam two years after installation. Speaking at an event held by the UK Indoor Environment Group (UKIEG) in May, UK scientist Dzhordzio Naldzhiev discussed both his own research at UCL, and research carried out by the US National Institute of Standards and Technology (NIST). In lab tests at NIST, Dr Dustin Poppendeik and colleagues1 found a number of volatile organic compounds emitted from four different cured spray foam specimens: two relatively fresh samples (one open-cell, one closed-cell) supplied by an industry body, the American Chemistry Council, and two older specimens from real-life installations (again one open-cell, one closed-cell). Numerous compounds were detected – up to 80 in the case of one sample. The concentration of most of the volatile compounds fell progressively in the test chambers over time, however for the two open cell samples, levels of the semi-volatile flame-retardant tris (1-chloro-2-propyl) phosphate (TCPP) remained steady. Similar results were also seen with one of the closedcell samples. The authors suggest the unchanging emissions may have been because levels of flame retardant were high in the finished foam (the researchers cite reports that TCPP may comprise up to 12% of the mass of some spray foam formulations), meaning concentrations

24 | passivehouseplus.ie | Issue 28

in the foam did not fall as the flame retardant “offgassed”. They also note that emission rates varied by up to an order of magnitude for apparently similar products, meaning it was not possible to generalise conclusions from one foam to another. Even though TCPP is a common ingredient in polyurethane foam products, there are no currently agreed exposure limits for the flame retardant2. However, as the NIST researchers point out, TCPP is classified by the EPA Design for the Environment Program as having “a high hazard for reproductive and developmental effects”.3 The NIST researchers also measured levels of TCPP in the air of a test dwelling that had had the basement insulated with open-cell spray foam, two years previously. As the house was unfurnished, there were no other potential sources of flame retardant such as foam furniture to confuse the results. According to the research, which was also discussed by Dzhordzio Naldzhiev at the UKIEG event4, TCPP was detected in the air in the ground floor of the house, and in the basement. As levels in the basement were approximately double those in the house, the researchers concluded that the spray foam there was almost certainly the source of the TCPP in the building. The team had found that in the lab, TCPP emissions from open cell foam rose exponentially with temperature. This effect was echoed in the test house (see graph). The temperature in the basement was raised from just above 21C to around 28C – the sort of rise that can be expected during heat waves. Repeat sampling showed levels of TCPP in the basement air rising from around 2-3 µg/m3 at 21C to 7-12

µg/m3 at 28C – at least a three-fold increase. These findings “suggest that occupants may be exposed to measurable concentrations of the flame retardant TCPP two years after application of open-cell foam,” the researchers wrote. The US authors added the caveat that with only one real-life example tested, the research is still very limited, and it is not known how dependent emissions are on the particular product, or the way it was installed. Among the other compounds emitted from the spray foam specimens when they were fresh, Dustin Poppendieck and his colleagues at NIST detected 1,2 dichloropropane (1,2- DCP) and 1,4 dioxane. “1,4 dioxane is commonly detected emitting from closed-cell SPF [spray polyurethane foam],” the authors say.5 Canadian researchers have also reported that tests on spray foam specimens detected 1,4 dioxane.6 1,2- DCP and 1,4 dioxane are classified respectively as carcinogenic,7 and possibly carcinogenic. However, little is known about how they originate and whether they pose a health hazard in real-world applications, or even the best way to measure the chemicals. At UCL, Dzhordzhio Naldzhiev is starting the process of investigating emissions of 1,4 dioxane, 1,2- DCP, and other VOCs, from samples of different commercially available spray foam products, refining the measurement process so that a standardised method can be developed. Naldzhiev told the UKIEG that, as part of as-yet unpublished research, he and his colleagues analysed three commercially available spray foam products to see if these two VOCs were present, and whether it was


possible to work out where they originated. The lab had detected 1,2- DCP being emitted from all three cured samples, and 1,4 dioxane only from one – but both compounds were found in the raw ingredients. It has been suggested in the US literature that 1,4 dioxane and 1,2- DCP may be breakdown products of TCPP.8 Although they say they can’t be sure either way, Dzhordzhio Nadzhiev and his colleagues believe these VOCs might instead have found their way into the foam as constituents of raw SPF product, possibly as contaminants, so it might be possible to modify the manufacturing process to reduce or eliminate them. Dr Naldzhiev’s team plan to investigate further, to establish the ‘real life’ levels of VOCs emitted by various spray foam products over one to two years or longer, and whether these are high enough to warrant concern. He added: “It is important to find the source and quantity of such emissions as it is a better strategy to eliminate them at the source, rather than mitigating them through ventilation strategies.” He and his colleagues are concerned that use of SPFs is outstripping understanding of their possible impacts on the indoor environment. In a research paper presented at an international ventilation conference in 2017,9 they wrote that “the potential long-term impact of these buildings materials and what ventilation strategies should be in place throughout the lifecycle of the building, in order to provide healthy IAQ, is still widely unknown.” Persistent formaldehyde off-gassing Another apparently persistent compound discussed at the UKIEG meeting last year was

formaldehyde, which also appears to persist for a year or more after the completion of construction, and does not necessarily drop to safe levels before occupants move in. Formaldehyde is a known irritant and suspected carcinogen, emitted by many engineered wood products and other construction and fit-out materials. As part of as-yet unpublished research, Dr Clive Shrubsole and colleagues at UCL in London and Tsinghua University, Beijing, monitored a number of chemicals in indoor air in a range of buildings, including schools, offices and homes, in the UK and China. Dr Shrubsole told the UKIEG: “We found formaldehyde levels of three times the recommended emission limit value in all the apartments we monitored, more than three years after the buildings were completed.” This raises a question over the perceived wisdom that formaldehyde will have mainly off-gassed within a couple of years, Dr Shrubsole warned. Dr Shrubsole’s findings were not an isolated instance. Tim Robinson of air testing company Waverton Analytics has also found elevated formaldehyde levels in a building post-occupation. He told a meeting of the Alliance for Sustainable Building Products in 201710 that he had recorded formaldehyde at ten times the WHO recommended limits in a school in Northwest England, one year after the building was occupied. Staff and students had complained of symptoms such as eye and throat irritation. However, the UCL/Tsinghua study found “no notable” formaldehyde in a building which had been constructed to a low-emissivity specification. This suggests source control can be effective.

TCPP concentrations in the basement of a test house at different temperatures; the basement had previously been insulated with open-cell spray foam. From: Flame Retardant Emissions from Spray Polyurethane Foam Insulation D. Poppendieck, M. Schlegel, A. Connor, A. Blickley NIST

1 ‘Lessons Learned from Spray Polyurethane Foam Emission Testing using Micro-chambers’; Dustin Poppendieck, Mengyan Gong, Lauren Lawson, National Institute of Standards and Technology (https://ws680.nist.gov/publication/get_pdf.cfm?pub_id=921259) 2 (A Research paper published by the American Chemistry Council in 2014 says: “There is no Occupational Safety & Health Administration (OSHA) permissible exposure limit (PEL) nor American Conference of Industrial Hygienists (ACGIH) Threshold Limit Value (TLV) guideline for the flame retardant, Trichloropropyl phosphate (TCPP).”) 3 USEPA, ‘Flame Retardants Used in Flexible Polyurethane Foam: An Alternatives Assessment’. Update. In Environment, D. f. t., Ed. U.S. EPA: 2014 cited by Poppendeik et al ‘Flame Retardant Emissions from Spray Polyurethane Foam Insulation’. 4 ‘Flame Retardant Emissions from Spray Polyurethane Foam Insulation’; D. Poppendieck, M. Schlegel, A. Connor, A. Blickley, National Institute of Standards and Technology. 5 ‘Lessons Learned from Spray Polyurethane Foam Emission Testing using Micro-chamber’; Poppendeik & al. 6 NRC Publications Archive / Archives des publications du CNRC, ‘Material emissions testing: VOCs from wood, paint, and insulation materials’; Won, Doyun; Nong, Gang; Yang, Wenping; Collins, Peter (http://doi. org/10.4224/23002015). 7 https://monographs.iarc.fr/list-of-classifications-volumes/ 8 Salthammer, T., Fuhrmann, F. & Uhde, E., 2003. ‘Flame retardants in the indoor environment—part II: release of VOCs (triethyl phosphate and halogenated degradation products) from polyurethane.’ Indoor Air, Volume 13, pp. 49-52. 9 https://www.aivc.org/news/aivc-conference-2017 10 https://asbp.org.uk/wp-content/uploads/2017/02/tim-Robinson-Waverton-ASBPExpo-15-02-20171.pdf 11 https://www.epa.gov/saferchoice/potential-chemical-exposures-spray-polyurethane-foam

Spray foam installation: What installers & occupants need to know There is long-standing concern about emissions during and immediately after insulation spraying, and what this means both for construction workers, and for occupants entering or re-entering a treated building. Isocyanates (“MDI”) are one of the main ingredients of spray foam – they comprise the “A” side in twocomponent foams. Isocyanates are an irritant and can cause a dangerous asthma-type reaction in people who become sensitised to them. Advice on the website of the US Environmental Protection Agency (EPA)11 warns of the following in relation to Isocyanates and other spray foam ingredients: •

Spray application generates isocyanate vapours and aerosols. Isocyanates can cause “sensitization,” which means that some people may become allergic to isocyanates and could experience allergic reactions including: itching and watery eyes, skin rashes, asthma, and other breathing difficulties. Symptoms may also be delayed up to several hours after exposure.

If you are allergic or become sensitized, even low concentrations of isocyanates can trigger a severe asthma attack or other lung effects, or a potentially fatal reaction. There is no recognized safe level of exposure to isocyanates for sensitized individuals.

Research data indicates that inhalation exposures during SPF insulation [installation] will typically exceed US Occupational Safety and Health Administration (OSHA) occupational exposure limits (OELs) and requires skin, eye and respiratory protection.

Vapours and aerosols can migrate through the building if the area is not isolated and properly ventilated.

After application, vapours may linger in a building until properly ventilated and thoroughly cleaned.

Cutting or trimming the foam as it hardens (tack-free phase) may generate dust that may contain unreacted isocyanates and other chemicals.

After application, dust may linger in a building until properly ventilated and thoroughly cleaned.

ph+ | dispatches | 25


Neil May 1962-2018

“Only if we are capable of dwelling, only then can we build.” Heidegger

N

eil May was a charismatic leader of our industry, a powerhouse of ideas who challenged and inspired everyone he worked with. The theme of his work was better buildings – not just better functionally or architecturally but also socially, culturally, ecologically and philosophically. He taught us to think about what buildings are for, what their place is in our heritage and society, the role they should fulfil in our future, and how they should perform. In his own words:

NBT’s chilly warehouse near Aylesbury. Neil inspired the group’s work promoting sustainable new-buildings and sustainable retrofit. One member of the group recalls “his passion for buildings, people and nature, (always those three things inextricably linked together) and his slightly bemused irritation that the construction industry and so much of society just didn’t ‘get it’, particularly when the evidence was clear for us to see.” Neil also contributed sustainability workshops to the

What are buildings for? And that leads to the question: what are human beings for? What is our purpose? We need to think deeply about that if we are to create a future that is sustainable as well as meaningful. Buildings are manifestations of the values of our society and if we want to have more beautiful, sustainable and creative buildings then we have to address our core values first. Neil studied for his first degree in Modern History at Oxford and went on to take an MPhil in Sociology at Delhi University, where he was a Commonwealth Scholar and specialised in cultural anthropology. He conducted extensive field work in and around Delhi and made a documentary film in Bihar. Neil remained in contact with leading anthropologists and social thinkers in Delhi, where his work is still respected. In 1988, having returned to the UK, he became a building labourer for four years before setting up his own award-winning ecological and conservation building company, Neil May Builders, which he sold in 2004. At heart, Neil was always a builder – he knew how to put buildings together, and his straightforward, practical manner often somehow conveyed the impression that he had just been building a wall or installing some plumbing. Yet he was equally comfortable with professionals, academics and civil servants. Working with academics, he encouraged them to focus on making their work useful; but with professionals he insisted on systematic research and evidence-based conclusions. Neil founded Natural Building Technologies in 1999, and pioneered the supply of high-performance sustainable, vapour permeable insulation and envelope systems for buildings. While managing director of NBT he set up the Better Buildings Group, including many leading energy and sustainability consultants who held meetings and seminars in

26 | passivehouseplus.ie | Issue 28

senior management development programme of a leading building company, where he is reported to have astonished the delegates with his insight into the many and various unintended consequences of poor design. In 2005, Neil brought together a group of natural building developers to campaign against the poor standard of performance of new homes in the UK. This was the start of a long collaboration with the Sustainable Development Foundation, which resulted in the creation of the Good Homes Alliance, the Passivhaus Trust, the Alliance for Sustainable Building Products and the Sustainable Traditional Buildings Alliance, each of which campaigned to change practice relating to performance problems that Neil had identified. Neil was instrumental in establishing and nurturing all these organisations, before moving on to sort out the next problem on his list! As a colleague remarked “Neil had the wonderful gift of bringing people together into communities of interest, creating what at first seemed to be niche groups but ended up becoming hugely influential for change at a national level.” When the UK government conceived the Green Deal, Neil was appalled by the potential for damage to our homes and architectural heritage from large-scale retrofit using inappropriate materials and techniques, a cause he took up with the Department for Energy and Climate Change (DECC). One civil servant at DECC recalls him as “A passionate


lobbyist for doing the right thing, who did it in the nicest possible way. You had your arm twisted without realising it.” For the Sustainable Traditional Buildings Alliance, Neil secured DECC funding for research that led to the influential report Responsible Retrofit of Traditional Buildings and the development of the well-known Guidance Wheel. Neil also contributed to the Each Home Counts review, and joined the BSI Retrofit Standards Task Group, where he was influential in establishing a holistic vision for the retrofit standards framework called for by the review. This in turn influenced the scope of BSI’s forthcoming domestic retrofit standard PAS 2035 Retrofitting Dwellings for Improved Energy Efficiency, for which Neil served as a member of the industry steering group. Neil’s work on responsible retrofit led to an opportunity to join the Institute for Environmental Design and Engineering at University College London (UCL) as a Senior Research Fellow. He had an immediate impact: as one colleague put it: “I am one of many with whom Neil collided and bounced off, sending us in new directions. He changed the way I think about housing. The intellectual challenges he posed were matched by personal warmth which made engaging with his ideas much more than just another collaboration.” Neil was also influential in establishing a ‘systems thinking’ approach within the Institute – he guided the development of the ground-breaking Housing, Energy and Wellbeing project. Colleagues in UCL’s Bartlett School of Planning report that his enthusiasm for thinking differently about the housing crisis was infectious. “We quickly understood that his knowledge and interests were almost boundless. UCL’s ‘Rethinking Housing’ initiative followed, bringing together researchers from UCL and beyond, and a new urgency in our housing work – driven by Neil.” The work on responsible retrofit also led Neil to BSI, where he collaborated on a White Paper on Moisture in Buildings, which advocates a new principles-based approach for moisture risk assessment that is being incorporated in a new edition of BS 5250 Code of practice for the control of condensation in buildings. His collaborator writes “Meeting Neil was a shock to the system, he had so much enthusiasm, so many interests, so many new perspectives on well-trodden ground and so much warmth and friendship. The White Paper stands as a tribute to him.” In parallel with the BSI work, the most recent of Neil’s projects was the establishment in 2016 of the UK Centre for Moisture in Buildings, at UCL. The Centre brings together partners from UCL, BRE, Heriot Watt University and the London School of Hygiene and Tropical Medicine. Already UKCMB has over twenty projects completed or in progress, funded by Government,

a research council, charitable trusts, industry bodies and commercial clients and sponsors, all driven by Neil’s enthusiasm. He led major projects for BEIS, Bristol City Council, Historic England and the National Trust. The UKCMB has also launched a training programme that promotes the principles of moisture risk management that Neil identified for the BSI White Paper and BS 5250.

A passionate lobbyist for doing the right thing, who did it in the nicest possible way. You had your arm twisted without realising it. A UKCMB academic at UCL writes “I feel honoured and privileged to have worked with Neil and been a part of UKCMB, the last of his countless brainchildren. We worked, conversed, argued and laughed – he never ceased to surprise with the depth and richness of his intellect and experience”. Another member of UKCMB remarks “Neil was interested in people as much as what they had to contribute, and it wasn’t long before we became friends as well as colleagues. I was impressed that, no matter how complex or mountainous a task, he was never fazed. His knowledge and intellect allowed him to join up the dots. Much good has stemmed from that, and it will continue to be his legacy.” An industry colleague remarks “Neil knew what sustainability meant for buildings and crucially for people – the two were inseparable and had to be in harmony. This understanding elevated his work beyond a technical level and made him effective in communicating his vision to others.” Neil was an adviser on environmental and building matters to the Benedictine Community at Quarr Abbey on the Isle of Wight, and he took a group of UCL colleagues there to experience the life of the monks and help them understand Neil’s own life and research philosophy. Of his work for the community, Neil wrote: “Part of its mission is to present an alternative and challenging vision of what it means to be fully human, and that is why I am involved.” In 2017 Neil was awarded an MBE ‘for services to sustainability and energy efficiency in buildings and communities’. In 2018, faced with an inevitably fatal condition and having survived one operation, Neil bravely chose to put his affairs in order, hand-over his work to colleagues and submit to a second, very risky surgical procedure. The outcome was this tragic loss, which for so many of us is painful and personal, but he has left us an immense and inspiring legacy of ideas and challenges. n

This obituary has been compiled from material contributed by some of Neil’s many friends and colleagues, including academics at UCL, members of the organisations he helped to found and run, and individuals who worked with him.

ph+ | obituary | 27


Case study houses:

1945 - 1962

In his latest piece on the evolution of low energy design, Dr Marc Ó Riain focuses on a postwar architectural movement that fused passive solar design with innovative materials in an attempt to deliver scalable, quality housing.

B

y the end of WW2, many European architects had relocated to the US forming a new definition of modern architecture. In the US Gropius had argued for an architectural regionalism, varying solutions to local climates. The technology and knowledge of solar houses were being promoted to architects and their clients by publications like ‘Tomorrow’s House’ (1945) and ‘Your Solar House’ (1947) illustrating that architects of the time were well aware of the principles and technologies of solar architecture. Orientation, overhanging shading devices, double glazing, concrete floor slabs, thermal mass, underfloor heating, and water attenuation for evaporative cooling were all known and applied solutions. But the war period had resulted in limited housing production, a shortage in materials and a lack of skilled labor, and as WW2 ended the US was facing into an immediate oil and housing shortage. One-off housing would not be able to address the housing shortages that faced the US as soldiers returned from war. Developers were best positioned to respond to this housing crisis in a meaningful way through larger housing developments known as ‘tract’ housing. John Entenza’s Arts & Architecture sponsored a ‘case study house program’ over a 17-year period around Los Angeles to illustrate how modern architecture could be harnessed to address this housing need. Fearing the potential dominance of developer-led housing, and their focus on conservative or well-established vernacular architecture, Entenza sponsored a program of low cost, small single-family housing from 1945-1962 (McCoy 1962) with standardised elements, using modern materials and new technologies which had arisen for the war. The aim of the ‘Case Study House Program’ (McCoy 1962) was to create template-comfortable modern houses that could be replicated as tract housing and adopted by developers. These houses were designed by young architects like Eames, Saarinen, Koenig, Neutra, Elwood and Soriano. The Eames house is well known but atypical of the rest of the program, in that it did not address the key functional needs of providing accommodation for a young family with two children. Talented young architects were challenged to develop modern solutions to middle class living. The case study houses were small (1,600-2,000 sq ft), but elegantly planned,

28 | passivehouseplus.ie | Issue 28

with two bedrooms and two bathrooms, close in ethos to the social planning of Wright’s Usonian houses. The designs which can be loosely divided into steel frame and timber frame post and beam structures were all located in the suburbs around LA. The architects demonstrated a strong sense of climate awareness and were very challenged by the lack of materials and technological limitations. Most of the designs were single-storey, based on flat underfloor heated floor slabs, with floor to ceiling glazing (some single and some double). They were oriented towards the sun and garden, and away from the street, with large overhangs to create solar shading. The architects designed the houses with informal open plan kitchen / living room spaces, eliminating corridors and gaining bathrooms for each bedroom. Outdoor spaces were integrated intelligently into the designs and often part of the internal plan, with Ralph Rapson’s 1945 Greenbelt house split by an internal garden. Smith’s 1945 ‘Loggia House” used Adobe to insulate the building from “warm Pasadena Summers” (McCoy 1962) and Wurster/Bernardi’s 1949 case study house had 1/3 of the roof glazed with louvres for sun control. The case study houses were opened to the public with the first six houses attracting 368,554 visitors or about 20% of the city’s population. Disproving the lenders and the developers some of the houses sold for 90%-125% more than their build costs in the early 1960s. Entenza had intended to create buildings that could change developer-led tract housing, but this was never realized outside of a small development in La Jolla, and some apartment schemes in the mid 60s. Despite this, the principles of planning, materiality and design remain a core part of

(above) Killingsworth, Brady, Smith & Associates’ Triad apartment scheme in La Jolla was part of an attempt to change developer-led tract housing. Photo: Arts & Architecture

today’s architect’s response to the design of houses. Wouldn’t it be wonderful if we could produce passive houses today with the joy and lightness of these buildings? Perhaps we can! Ester McCoy’s or Taschen’s books on case study houses are great for more detail. Whilst the case study houses signaled a departure towards modernism in US residential architecture, other programs and other architects were moving toward a more scientific method of designing housing. In the next issue we will look at emergent trends in science of housing design in the post war period. n

Dr Marc Ó Riain is a lecturer at the Department of Architecture at Cork Institute of Technology, one of the founding editors of Iterations design research journal and practice review, a former president of the Institute of Designers in Ireland, and has completed a PhD in low energy building retrofit, realising Ireland’s first commercial NZEB retrofit in 2013.


OUR EXPERTISE

YOUR COMFORT

Solutions for every idea. Daikin Altherma low energy, BER compliant Air Source Heat Pumps. Heat Recovery Ventilation Systems for both new and retrofit projects.

info@rosstechnical.ie Tel: (087) 2503115

SPECIALISTS IN THE APPLICATION OF RENEWABLE ENERGY ph+ SOURCES | column | 29


What is a sustainable office building? As buildings with questionable sustainability credentials are lauded for their greenness, Dr Peter Rickaby puts forward his vision for a genuinely sustainable office building.

T

he claim that the new Bloomberg European Headquarters building in London is “the world’s most sustainable office building” caught my eye. Even with a BREEAM score of 98.5% the claim clearly isn’t true: the building must have a huge carbon footprint associated with the journeys to work of the 4,000 people who work there. And what about the 600 tonnes of Japanese bronze and 10,000 tonnes of Indian granite? And a deep plan lit by half a million LED lamps? Credit is due to the clients, architects and engineers for making an effort, but this is not a sustainable building. It is just a little less unsustainable than the buildings that surround it. There must be some passive house office buildings out there that get much closer. This set me thinking about what a truly sustainable building might be like. If it meets the Bruntland definition of sustainability it would leave little or no environmental footprint. I have never seen such a building. Well, maybe one – the forester’s self-build house in the woods that was featured on Grand Designs a few years ago. But what characteristics might a sustainable office building have? First, it would not be big. The bigger the building the more people will work there and the further they will have to travel, so it’s a local office or perhaps a local work centre. The occupants live locally and arrive on foot or by bicycle. (Or perhaps they all work from home and don’t need an office building.) If it’s too big it will have either a deep plan needing artificial lighting and air conditioning, or a complicated shape that will facilitate daylighting but increase surface area and heat losses. Or it may be tall, needing more structural material and lifts. I think our sustainable office building would be compact, not too densely occupied, and day-lit - small is beautiful! Second, it would be made of sustainable materials that need little or no fossil fuel to produce, and preferably could be sourced locally. So, no concrete or steel. Aluminium might be acceptable – most of it is smelted using hydropower, and almost all of it is recycled, but it travels a long way. Glass is a problem – it takes lots of energy to manufacture (you must melt sand) and nobody does it with renewable energy yet. But glass is quite useful for letting daylight in and providing views out, while keeping out the rain and wind, so we may have to wait for

30 | passivehouseplus.ie | Issue 28

low-carbon glass, and in the meantime use less glass, and re-use what we have. The structure would be timber, I think – trees remove carbon dioxide from the atmosphere and sequester carbon in timber. So long-life, re-useable timber frames and cladding perhaps? Bricks and clay tiles need firing in kilns, and they are heavy to transport, so they don’t seem a good idea. Floors would be timber. The roof would

would of course be a certified passive house, and (by virtue of the renewables) an nZEB. It would also be manufactured off-site, delivered in panel form (because delivering volumetric buildings, i.e. transporting air, is a waste) and assembled on site. When no longer needed it would be reconfigured, or dismantled and reassembled elsewhere, and some elements might be recycled. I wonder what its BREEAM score might be? n

Our sustainable office building would be highly insulated and airtight, so it would need little or no heating, other than by internal gains, but it would be lightweight so keeping it cool might be a problem.

be a green roof or covered in slate or timber shingles. Insulation could be cellulose, cork, flax, hemp, wood fibre, sheep’s wool or straw bales – there are lots of options! There would be no oil-based plastic insulation boards or mineral fibre (which involves melting rock). Whatever we use, the building elements would have to be quite thick. Our sustainable office building would be highly insulated and airtight, so it would need little or no heating, other than by internal gains, but it would be lightweight so keeping it cool might be a problem. However, internal heat gains would be low, because of modest occupant density, and energy efficient lighting and IT. Solar gains would be reduced by shading or shutters. It would be good to introduce some thermal capacity somewhere, to smooth the internal temperatures, possibly via a local stone ground floor. A hybrid of smart natural ventilation (lots of controllable openings, including in the roof) with demand-controlled decentralised mechanical extract ventilation might be an option. Heat and hot water demand would be met by solar thermal systems and electric heat pumps. Power would be provided by community wind turbines, by wind farms connected via the national grid, and by roofmounted solar photovoltaics. The power distribution system would be low-voltage DC, which suits both solar PV and computer systems, and minimises transformer losses. Diurnal and inter-seasonal energy storage would be provided by tanks and batteries. Overall, our sustainable office building

Dr Peter Rickaby is an independent energy and sustainability consultant and Chair of the BSI Retrofit Standards Task Group.


SMART DATA FOR PASSIVE HOUSE VRM Tech and BUILT2SPEC are pleased to introduce the VCMP (Virtual Construction Management Platform). Integrating with the Passive House Certification Platform, VCMP provides construction professionals with a central cloud-based platform and mobile apps to coordinate work activities onsite, easily share the latest documents and creates the evidence folders that will allow qualified professionals to remotely evaluate the construction progress and create issues where the evidence presented is not adhering to the specified requirements.

3 months

ROI within and up to administration work per job.

40% reduction in

+353 1 525 2710 info@vrmtech.ie www.vrmtech.ie

ph+ | column | 31


GOOD M E W S STO RY IN DÚN LAOGHAIRE

An award-winning social housing development in South Dublin points to a sustainable way out of Ireland’s housing crisis.

Words by Jason Walsh

Building: Four 55 square metre apartments Location: Sallynoggin, Dún Laoghaire, Dublin Completed: December 2017 Standard: Nearly zero energy building (nZEB) Energy bills: Unavailable – monitoring underway

32 | passivehouseplus.ie | Issue 28


It was intentionally a very simple design that any contractor could replicate.

T

he architects’ department in Dún Laoghaire-Rathdown County Council has done something impressive: by building The Mews in Sallynoggin, a development of four apartments, it has proved that, even in the midst of a housing crisis, we are capable of building homes that are sustainable, comfortable and healthy. That they are also social housing only strengthens the case. Unfairly, local authority building projects tend to be the poor cousin when it comes to reporting on construction and development. Of course, this is not surprising: much architecture coverage, particularly in popular media, focuses on either giant buildings by ‘starchitects’ or else Grand Designs-like one-off houses. Neither is without merit, and ideas do cross pollinate, but neither corporate headquarters nor flashy one-off houses are the be-all and end-all of architecture. Dún Laoghaire-Rathdown has long been noted as one of the more progressive local authorities in Ireland, both in terms of sustainability and social housing. It was one of the first councils to adopt its own tougher building energy standards locally, back in 2007. Then in 2016, the council introduced a rule that all new homes in the district must be to “passive house or equivalent” standards. Local authority architect Joanne Maher says that while energy conservation is central to it, the core mission of sustainability is a wider issue, and one that she tries to build into her own work. This includes environmental concerns, but also wider social issues. “What we were trying to achieve was a social as well as environmental build, [and] what the RIAI [Royal Institute of the Architects of Ireland] felt was that the scheme could be easily replicated, but also [that it] addressed two issues: how to increase housing supply and also what to do

ph+ | case study | 33


WANT TO KNOW MORE? The digital version of this magazine includes access to exclusive galleries of architectural drawings. The digital magazine is available to subscribers on www.passive.ie

about our existing low-density suburbs.” The RIAI’s interest was not just a case of a nice notice: The Mews won the sustainability category at the 2018 RIAI Architecture Awards. The Mews blitzes Ireland’s incoming nearly zero energy building (nZEB) standard (see ‘nZEB? No problem’), with all the units achieving A1 building energy ratings. And while it did not aim for passive house certification, the spec is for insulation, thermal bridging, airtightness and ventilation — along with the building’s comparatively simple, compact form and sensible glazing levels — are straight out of the passive house playbook. Indeed, one of the primary design goals at The Mews was to keep things simple, using traditional cavity wall construction with a strip foundation, for a start. According to Maher, this was done in order to develop a form of building that does not require massive amounts of re-training for tradespeople on site. “It was intentionally a very simple design that any contractor could replicate,” she says. “It was full-fill cavity insulation; it’s a straightforward, known system, and because of the compact shape we didn’t have any thermal bridging.” The team used Cavalok BigBlok cavity closers during the build, which provide a frame in window and door openings around which blocks can be laid, while simultaneously sealing up cavities up

34 | passivehouseplus.ie | Issue 28

to 300m wide. Issues such as passive solar gain were also considered. “The building has a 170 square metre footprint [so] it’s quite dense, but in its shape and orientation it’s very simple: it’s a rectangular block with the main orientation to the southwest, with the glazing facing that way and very small windows to the northeast,” Maher says. “We always think about things like solar gain and loss and cross ventilation.” In terms of buildings services, there is a small Dimplex heat pump generating hot water, and a heat recovery ventilation system. Space heating is provided by four radiant Dimplex electric panels in each apartment, while four solar photovoltaic panels on the roof help to meet electricity demand. Dún Laoghaire-Rathdown County Council is currently in the early stages of monitoring temperature, humidity and indoor air quality in the dwellings. This design simplicity also appears to have paid-off in more ways than simply impressing the majordomos at the RIAI. As a result, The Mews is as much a model for the future as it is a social housing development. “One thing we were trying to show was that you can achieve airtightness through good detailing and good energy performance through materials, but do so with what was a typical build: we wanted to keep things to a

The Mews is as much a model for the future as it is a social housing development.


nZEB? No problem The apartments at the Mews qualify as nearly zero energy buildings (nZEBs) because of their remarkably low energy & carbon performance coefficients (EPC & CPCs) in Deap, the software used in Ireland to calculate building energy ratings (BERs) and verify compliance with Part L of the building regulations. Both the EPC and CPC are overall scores that take into account a wide range of energy efficiency factors like insulation, airtightness, the efficiency of heating systems and any renewable energy systems. Under EU rules, all new homes must be nZEBs from the 31st December 2020, though each country has certain freedom to define their own nZEB standard. In Ireland, under the new version of Part L for homes set to come into force next year, dwellings must have maximum EPCs and CPCs of 0.3 and 0.35 respectively to meet nZEB. With EPCs and CPCs of around 0.1, the apartments at The Mews easily beat these targets.

Photography: Donal Murphy

simple way,” says Maher. The construction process itself – oftentimes ground zero for conflict – was also smooth, she says, with a wry joke. “The build went very well. Everyone was talking to each other at the end, which was really good. “The contractor hadn’t any experience with passive house or what we were trying to achieve but they were very willing to learn and ready to take it on board. We were very lucky with them,” she says. Maher strikes a pragmatic note, saying that while new techniques are always welcome, a path of least resistance can also be used to produce sustainability – if the design is right. “No-one is really interested in going out and spending money and learning if they don’t have to. We also had to work within a budget.” In a way the apartments are modest enough: clean and modern in design rather than proffering the ‘shock of the new’, and intended to belong to the community in a general sense of not being jarring. This is perhaps the greatest success of The Mews and its designers, though: by thinking in terms of social need Maher and her colleagues were able to create a repeatable scheme that, if widely applied, could go some way to both easing the ongoing housing crisis and also improving the overall Irish housing stock. Built on a garden site, the building also

seeks to address the issue of low density in the south Dublin suburb. As it is suitable for elderly or less abled inhabitants it has a further social function in that it promotes continuity and cohesion. “It allowed the residents to stay in their locality, rather than have to move out,” she says. The bottom two units are wheelchair accessible, and all four units feature braille signage, with the designers and council recognising that they needed to think about the occupier in the broadest possible terms: the goal was to give them freedom, Maher says. “We never know who’s going to use a unit. It was important, for instance, to have turning circles and allow it to be completely open and accessible, and to use materials that were neutral to allow people to put their own stamp on it at as home.”

It allowed the residents to stay in their locality, rather than have to move.

ph+ | case study | 35


CONSTRUCTION IN PROGRESS

1

2

3

4

5

6

7

8

9

1 The ground floor features several courses of Quinn Lite AAC blocks to minimise thermal bridging, plus a radon barrier; 2 Cavalok BigBlok cavity closers provide a thermally broken frame in window and door openings around which blocks can be laid, while simultaneously sealing up the wall cavities; 3, 4 & 5 the build is traditional cavity wall construction, with full-fill Xtratherm Cavitytherm rigid PIR insulation, a method chosen for its simplicity and repeatability; 6 installation of the triple-glazed Rationel aluclad windows; 7 Intello vapour control layer installed at ceiling level with airtightness taping at seams, where it meets the wall, and at cable penetrations; 8 the Fakro Eurotop S65 breather membrane protects the roof structure against moisture; 9 Xtratherm insulation installed over roof afters under the membrane. (opposite, top right & bottom right) Dimplex EDEL hot water heat pump integrated in 200 litre domestic hot water Tank & Xpelair Xcell 150QV MVHR System.

36 | passivehouseplus.ie | Issue 28


SELECTED PROJECT DETAILS Client: Dún Laoghaire – Rathdown County Council Architects: Dún Laoghaire – Rathdown County Council Architects’ Department (clerk of works, Aidan Shannon; project architect, Joanne Maher; county architect, Andree Dargan) Contractor: Bracegrade Ltd Health & safety: Scott & MacNeill Quantity surveyor: Nolan Construction Consultants Mechanical & electrical engineer: Delap & Waller Assigned certifier / civil & structural engineer: Punch Consulting Engineers BER assessor: Geraghty Energy Consultants Fire consultant: John McCarthy Airtightness consultant: IHER Energy Services Airtightness tester: Evolved Energy Solutions Airtightness products: Ecological Building Systems / Siga Thermal breaks: Schöck, via Contech Thermal blocks: Quinn Building Products Wall & roof insulation: Xtratherm Windows: Rationel Landscaping: MCD Landscapes

ph+ | case study | 37


CavityTherm

ÂŽ

For more information contact our Technical Team

It’s not just about U-Values

T 046 906 6050 www.xtratherm.ie

CavityTherm wall insulation delivers not only passive U-Values but also the detailing to combat thermal bridging heat loss.

Accessories:

A continuous wall insulation system delivering ultimate thermal performance with the added assurance of inbuilt protection from wind driven rain.

Accessories:

Integral Rain Barrier

Preformed Corner Panels

Service Void Panels

Jointing Strip

Hockey Stick Insulation

Cavity Tray Channel

38 | passivehouseplus.ie | Issue 28


ph+ | case study | 39


Flexible wood fibre insulation batts Blow-in wood fibre insulation Rigid wood fibre insulation boards Chips and shavings

Vapour permeable wood fibreboards for walls, roofs and floors

Manufacturing ecological insulation for over 85 years in the Blackforest, Germany.

T. 046 9432104

info@ecologicalbuildingsystems.com w w w. e c o l o g i c a l b u i l d i n g s y s t e m s . c o m

CREATING A SECURE AND COMFORTABLE ENVIRONMENT IN THE HOME

Your vision for Living Phone 01 2971005

Fax 01 2971070

Email enquiries@rationel.ie

40 | passivehouseplus.ie | Issue 28

Website www.rationel.ie


General requirement of the contract:

The contractor should note that the wor provide aesthetic qualities unique to this project and that aesthetic If the contractor intents to substitute a specified material with one equivalent then he/she should note that aesthetics will be an essential facto equivalence. The employer’s representative will not permit the use of equivalent, both aesthetically and technically, with what is specified in the

  

The overriding intention is that all work be doneto a sound and durable standard.Everything needed to end result,whether or not it is either drawn or speci to be provided for and executed by the Contractor, within the tender price.

  



 















 











NORTH ELEVATION

OUTLINE SPECIFICATION

General requirement of the contract: The contractor should note that the works have been designed to provide aesthetic qualities unique to this project and that aesthetics is a functional requirement. If the contractor intents to substitute a specified material with one that he/she deems equivalent then he/she should note that aesthetics will be an essential factor in determining equivalence. The employer’s representative will not permit the use of any material not fully equivalent, both aesthetically and technically, with what is specified in the contract documents.

  

The overriding intention is that all work be doneto a good solid, sound and durable standard.Everything needed to ensure this end result,whether or not it is either drawn or specified, is to be provided for and executed by the Contractor, within the tender price.

  







THE PROPOSED DEVELOPMENT HAS BEEN CARRIED OUT TO PASSIVE HOUSE STANDARD. Space Heating Demand not to exceed 15kWh annually OR 10W (peak demand) per square metre of usable living space  Space Cooling Demand  roughly matches the heat demand with an additional, climate-dependent allowance for dehumidification Primary Energy Demand not to exceed 120kWh annually for all domestic applications  (heating, cooling, hot water and domestic electricity) per square meter of usable living space Airtightness   per hour at 50 Pascals pressure (as maximum of 0.6 air changes  verified with an onsite pressure test in both pressurised and  depressurised states)  Thermal Comfort Thermal comfort must be met for all living areas year-round with not more than 10% of the hours in any given year over 25°C*

    



















 

OUTLINE SPECIFICATION





 01.GENERAL GROUND FLOOR BUILDUP: FINISH FLOOR ON 75MM CONCRETE SCREED ON 175MM THERMAL CONDUCTIVITY: 0.022 W/mK. INSULATION TAPED WITH PROPRIETARY TAPE ON RADON BARRIER ON  RC SLAB  ALL TO STRUCTURAL ENGINNERS DRAWINGS AND SPECIFICATION. FULL DPC WRAP TO AERATED CONCRETE BLOCKWORK AT FLOOR WALL JUNCTION







02.GENERAL EXTERNAL WALL BUILDUP: EXTERNAL RENDER TO CONCRETE BLOCKWORK 150MM PASSIVE PERFORMANCE FULL FILL CAVITY SYSTEM 0.11W/M2K, (ENSURE INSULATION IS SECURED  AGAINST INNER LEAF, LAP AND TAPE ALL JOINTS), FIRMLY BLOCKWORK OF THICKNESS AS SHOWN IN PLAN TO INNER LEAF AIRTIGHTNESS MEMBRANCE BONDED TO RADON BARRIER AND LAPPED WITH PARGE COAT INTERNALLY WITH SKIM FINISH. FULL PERIMITER/ 4 SIDED PASSIVE STANDARD STRUCTURAL CAVITY CLOSER AROUND ALL WINDOWS, DOORS AND PARAPETS WALL TIES TO HAVE LOW CONDUCTIVITY TO ENGINEER SPECIFICATION

















03.ALUMINUM PARAPET CAPPING PRESSED IN PROFILE AS SHOWN IN DETAILED DRAWINGS AND RAINWATER GOODS. . 04.PITCHED WARM ROOF ZINC WARM ROOF SYSTEM ON PLYWOOD BONDED TO PHENOLIC FOAM , SYSTEM BUILDUP U-value of 0.15W/m2K. OVER A CONTINOUS ALUMINIUM FOIL BACKED BITUMINOUS SELF SEALING VAPOUR BARRIER, AIRTIGHTNESS MEMBRANS CARRIED AROUND EDGE OF PLYWOOD AND BONDED WITH VAPOUR BARRIER OVER A PLYWOOD DECK. ON ROOF TRUSS TO STRUCTURAL ENGINEERS DRAWINGS AND SPECIFICATION. 05.FIRST FLOOR BUILDUP:





 



 













 

SOUTH ELEVATION

NORTH ELEVATION









  

STAIRWELL) ON 75MM SCREED ON 250MM HOLLOW CORE PRECAST CONCRETE SLAB ALL TO STRUCTURAL ENGINEERS DRAWINGS AND SPECIFICATION.

















IN DETAIL

  

Building type: Scheme of 4 x 55 sqm social housing units 



 





 



 





Location: Sallynoggin, Dún Laoghaire, Dublin 











SOUTH ELEVATION Completion date: December 2017

Measured energy consumption: Currently being monitored Airtightness (at 50 Pascals): dlr 2 0.94 m3/hr/m2 & 1.0 m3/hr/m

Do not scale from this Drawing, use figured dimensions only. Check all dimensions on site before commencing work. Report any discrepancies to Architect before proceeding. This Drawing and Designs thereon are copyright of the County Council. ©

Budget: €800,000 approx (excluding Vat)

Passive house certification: Not assessed Note: Figures are for one upstairs & one downstairs unit Space heating demand (DEAP): 6.5 kWh/m2/yr (upstairs unit). Primary energy demand (DEAP): 14.6 & 21.1 kWh/m2/yr (note: does not include plug loads) Heat loss form factor (DEAP): 2.45 & 2.8 Energy performance coefficient (EPC): 0.109 & 0.109 Carbon performance coefficient (CPC): 0.105 & 0.105

06.CEILING: GROUND FLOOR CEILING: SUSPENDED GYPSUM PLASTERBOARD LINED SUSPENDED CEILING SYSTEM FIRST FLOOR CEILING: 62.5MM INSULATION / 2 LAYERS GYPSUM PLASTERBOARD COMPOSITE BOARD WITH SKIM FINISH UNDERNEATH FIRE RESISTANT. 07.INTERNAL MASONRY WALLS 100/ 215 MM CONCRETE BLOCK WALLS TO RUN FROM FLOOR TO CEILINGS AS PER STRUCTURAL ENGINEERS DRAWINGS AND SPECIFICATONS 08.EXTERNAL DOORS / WINDOWS: COMPOSIT WINDOWS AND DOORS ALUMINIUM CLAD WOOD AS PER MAIN SPECIFICATION (U-value 0.76 W(m2)K. )ALUMINIUM EXTERIOR FRAME POLYESTER POWDER COATED TO RAL, TBA, INTERIOR FRAME EUROPEAN REDWOOD FACTORY PAINTED TO RAL TBA TRIPLE GLAZED TWO CONTINUOUS SEALED UNIT,( with a Ug of 0.6W/(m2K), Solar gain value of 0.80 with a light transmittance of 72%. Black warm edge spacers with 90% argon gas fill.) SAFETY GLASS BELOW 800MM IN ALL WINDOWS AND DOORS, OPAQUE GLASS TO BATHROOMS IRONMONGERY AS PER SCHEDULE 09.CANOPY/BALCONIES SEE DETAILS AND LAYOUT DRAWINGS 10.INTERNAL STAIRS AND HANDRAIL: SEE DETAILS AND LAYOUT DRAWINGS 11.INTERNAL JOINERY: SEE DETAILS AND LAYOUT DRAWINGS 12.SERVICE CUPBOARDS SEE DETAILS AND LAYOUT DRAWINGS. 13.DRAINAGE: SEE MECHANICAL AND ELECTRICAL ENGINEERS AND STRUCTURAL / CIVIL ENGINEERS DRAWINGS FOR DETAILS. INSULATE TIGHTLY AROUND SOIL VENT PIPES IN BATHROOM BUILDOUTS. SOIL VENT PIPES TO RISE UP TO ATTIC SPACE AND BEND TO EXTRACT AT REAR SIDE OF PITCHED ROOF 14.RAINWATER: ALUMINUM RAINWATER GEAR. ALL RAINWATER PIPES TO RUN DIRECTLY INTO GROUND AND TO BE CONNECTED INTO BACK INLET GULLEYS. SEE MAIN SPECIFICATION AND STRUCTURAL / CIVIL ENGINEERS FOR FURTHER DETAILS.

BER: A1 (14.6 kWh/m2/yr) & A1 (21.10 kWh/m2/yr)

Project

Comhairle Contae County Council

Drg

THE MEWS SALLYNOGGIN PARK NORTH ELEVATION SOUTH ELEVATION

Scale 1:50@A1 1:100@A3 Date

Tender

Roof: Pitched roof with Roadstone SL8 slate grey roof tiles externally, followed beneath by batten space, breather membrane, 75mm/100mm Xtratherm XO over rafters, 100m XtroLiner XO between rafters, vapour control layer, plasterboard. U-value: 0.13/0.11 W/m2K

CAD Ref -

Job No - 1809 Drn.

Chd.

Drg 100/007

Architects Department County Hall, Marine Road, Dun Laoghaire, Co. Dublin. Phone (01) 2054700 Fax (01) 2300391

Thermal bridging: Several courses of Quinn Lite AAC blocks at and above subfloor; Cavalok BigBlok cavity closers; Isokorb thermal breaks at balconies. Y-value of 0.08 W/m2K used – as per Acceptable Construction Details.

Rev A

Windows: Triple glazed Rationel aluclad argon-filled windows. Overall U-value: 0.79 to 0.82 W/m2K

Ground floor: Screed on Xtratherm XT/UF rigid PIR insulation, on radon membrane, on precast concrete slab. U-value: 54.74 W/m2K. Strip foundation to perimeter of building.

Heating system: Direct electric heating via Dimplex radiant electric heating panels, Dimplex EDEL hot water heat pump integrated in 200 litre domestic hot water tank, with co-efficient of performance of 3.43 (EN16147) and heat loss rate from cylinder of 1.85 kW per 24 hours. 
 Ventilation: Xpelair Xcell 150QV MVHR system with 89% heat recovery efficiency.

Walls: External render on concrete block, on full-fill Xtratherm Cavitytherm rigid PIR insulation, on concrete block. U-value: 0.15 W/ m2K. Quinn Lite thermal blocks to base of walls.

Electricity: 4 x Dimplex 300Wp solar PV panels with total electrical contribution of 980.16 kWh per year per dwelling (DEAP).

Energy bills: Unavailable

dlr

Comhairle Contae County Council

FINISH FLOOR ON 5MM SOUND IINSULATION UNDERLAY (NOT IN

    

 

Do not scale from this Drawing, use figured dimensions only. Check all dimensions on site before commencing work. Report any discrepancies to Architect before proceeding. This Drawing and Designs thereon are copyright of the County Council. ©

ph+ | case study | 41

Project

THE MEWS Drg

NORTH ELE


Tried & Tested Space heating, hot water & ventilation – the complete apartment solution from Dimplex. Glen Dimplex has developed a smart electric heating solution that ensures each home owner has control over their own standalone heating system, allowing up to 40% lower capital costs & greater efficiencies across apartment developments.

PART L COMPLIANT

• Highly controllable • Easy to maintain (no need for annual safety check)

1

• Lowest capital & installation costs • Can be placed anywhere there is an electrical connection • No district heating required

1

42 | passivehouseplus.ie | Issue 28

Dimplex Quantum

2

Dimplex Q-Rad

3

Dimplex Edel Hot Water Heat Pump


4

2

5

3 4

Dimplex PV System

5

Xpelair Heat Recovery Ventilation System

For more information on the complete range of Dimplex solutions, please visit www.dimplex.ie email: sales@dimplex.ie or call: +353 (0)1 8424277 ph+ | case study | 43


WANT TO KNOW MORE? The digital version of this magazine includes access to exclusive galleries of architectural drawings. The digital magazine is available to subscribers on www.passive.ie

44 44 | passivehouseplus.ie | Issue 28


H O LY T R I N I T Y Situated in a stunning location in the west of Ireland, between Galway Bay and the limestone hills of the Burren, this project provided a complex challenge in three parts: deep retrofit an old cottage into a yoga studio, reinvigorate its original extension, and build a new barrel-roofed passive-grade extension — then make it all work together as one unified home and workspace.

Words by Jason Walsh

€700 estimate for space heating

(see ‘In detail’ panel for more)

Building: 424 sqm home, office & yoga studio, in three sections Location: Kinvara, Co Galway Completed: August 2017 Standard: Passive-spec extension, deep retrofit to old cottage

Homeowners Keith & Amanda Horan

ph+ | case study | 45 45


Proposed 1FL 3.40 m Existing 1FL 2.91 m

Proposed 0FL 0.65 m Existing 0FL 0.00 m

2

Extension South Elevation 1 : 50

3

South Elevation 1 : 50

lot better,” he says. The Horans engaged architect Miles Sampson to produce a design for the three structures. “We were ecologically-minded but we didn’t really know how to go about it. It was then seeing Miles’s website that drew us in,” he says. The end result has been a very positive one for the family. “We’ve really learned a lot working with Miles. He jumped out: he was the first person I contacted, we had an initial meeting and that was that—we didn’t consider anyone else. He completely understands what he’s doing.” Horan says that, after discussions with Sampson, the brief was to create a space that was not only appropriately warm, but also full of light. “You’re looking for a space that connects to the outside: lots of natural light, comfortable, with good air, warm, using natural materials as much as possible. We had a vague idea of what we were looking for, but Miles crystallised it,” he says. Meanwhile, the contractor on the project was GreenTec Building, led by Niall Dolan, with foreman John Forde running the project on site. Sampson has now worked with GreenTec on numerous passive houses around the west of Ireland. Sampson explains that the three buildings that now comprise the finished home-and-workplace each has its own character — and needs. “Basically, there are three elements: the entirely new barrel-roof element, the previous extension, which is nine years old, and the cottage, which goes back a hundred years or so but had been renovated,” he says. The dwelling, in three discrete but interlinked parts, now consists of five bedrooms, with two on the ground floor of the new extension, and three in the old extension. The old extension also includes a den for the couple’s children, plus an office. The cottage has been turned over to use as the yoga studio. “The [new] extension gives a feeling of fitting in the landscape. It has a familiar air DRAFT with a barn-style roof, but it also has living space on the first floor, giving as much space as possible and, hence, a lot of light. With an A-roof you’d not be able to get the same amount of space.” Sampson says that with renovation work, a big part of the job is working with what is reasonable. “In the [new] extension, the performance is very much to passive standards, so everything on the extension is to the highest standard. Often, in a situation where we’re extending, we bring up the existing house to a very high standard too, but the previous renovations were only done nine years before, so it didn’t make sense to pull it apart. We did put in a heat recovery ventilation system [in the original extension].” Some draft-proofing work was also carried out on this part of the building to improve its airtightness too. Meanwhile the old cottage had previously been insulated Date Description Revision Schedule

100MM SCALE

No

Existing 1FL 2.91 m

Office for Architectural Research And Design

IRL: First Floor, 37 North Great Georges Street, Dublin 1 IRL: Kilcoran, Kilkishen, Co. Clare ESP: c/ Vidre 2, At, 08002 Barcelona T: +353 (0)61 749975 E: office@oarad.com

F: +353 (0)61 749875 W : www.oarad.com

CGB

PROJECT

Elevations II

TITLE

A301

SERIES

Existing 0FL 0.00 m

SHEET

1 : 50

REVISION SCALE AT A3

16/10/2018

FIRST ISSUE DATE

REVISION DATE

PURPOSE

1

Do not scale from drawing || Use figured dimensions only || Notify architect of all discrepancies || Read with relevant specification & consultant´s drawings || Print scale check, sheet outline = 287 X 410mm Drawing for planning purposes only, not for construction

East Elevation

COPYRIGHT

1 : 50

W

hen Amanda and Keith Horan wanted to extend their existing, partially upgraded, cottage near Kinvara, County Galway, they knew they wanted a sustainable building from day one, but their goals were not going to be easy to satisfy. They needed a family home, workspace and a yoga studio, and had three buildings to integrate into the plan — the old cottage, a nine-year old extension, and a large new extension that would be built to a passive house specification. “My wife is a yoga teacher and I’m a

46 | passivehouseplus.ie | Issue 28

mindfulness teacher,” says Keith Horan. The house as it stood—a traditional Irish cottage with a modern extension — already had a small yoga studio, but space was tight. This time, the plan would be to turn the old cottage into a full yoga studio. “Originally when we moved here, it was in 2005. There was an existing extension and we finished it: the walls were up but that was all. I was a secondary school teacher and Amanda was a yoga teacher [so] we built a small [yoga] space even back then. It was fine, it was a nice room, but now it’s a

C

MILES SAMPSON B.ARCH


internally with some drylining, but as it was set to be reconfigured into a yoga studio, the opportunity was taken to thermally upgrade the fabric further, fitting it out internally with sheep wool insulation and vapour control membranes – with a barrel vault ceiling that evokes the barrel-roofed extension. Horan says: “The one thing is, it still has the deep-set, cottage windows, but that works for yoga and meditation practice where there’s an inward focus. It gives a kind of snug feeling.” Sampson, one of Ireland’s more prominent ecologicalDRAFTarchitects, says that over time ly-minded building to the passive house standard has become the norm for him. “I’ve been practising fourteen or fifteen years now, and from the start I was doing eco-buildings. I very quickly got into passive housing. What started me was that I did a house with Duncan Stewart, and I remember it was timber frame with recycled insulation and a grass roof. “Toward the end of the project Duncan said: ‘Now that you’ve done this, you’ll have to do passive house’. I was a bit knocked back, but I looked into it, and one thing led to another.” Sampson says that clients sometimes want to obtain passive house certification, but many just want the performance advantages of a passive house. “We’ve a few certified but it tends to be that they want the performance rather than the certificate. The first one I had certified DRAFTor 2010 and I’m currently was in 2009 putting three through certification.” This time, however, the constraints of a No

Date Description Revision Schedule

100MM SCALE

N

Office for Architectural Research And Design

IRL: First Floor, 37 North Great Georges Street, Dublin 1 IRL: Kilcoran, Kilkishen, Co. Clare ESP: c/ Vidre 2, At, 08002 Barcelona T: +353 (0)61 749975 E: office@oarad.com

F: +353 (0)61 749875 W: www.oarad.com

CGB

PROJECT

First Floor Plan

TITLE

1 : 50

A901

SERIES

SHEET

REVISION SCALE AT A3

16/10/18

FIRST ISSUE DATE

REVISION DATE

PURPOSE

Do not scale from drawing || Use figured dimensions only || Notify architect of all discrepancies || Read with relevant specification & consultant´s drawings || Print scale check, sheet outline = 287 X 410mm Drawing for planning purposes only, not for construction COPYRIGHT

MVHR Unit Above

C

MILES SAMPSON B.ARCH

No

Date Description Revision Schedule

100MM SCALE

N

Office for Architectural Research And Design

IRL: First Floor, 37 North Great Georges Street, Dublin 1 IRL: Kilcoran, Kilkishen, Co. Clare ESP: c/ Vidre 2, At, 08002 Barcelona T: +353 (0)61 749975 E: office@oarad.com

F: +353 (0)61 749875 W: www.oarad.com

CGB

PROJECT

Ground Floor Plan

TITLE

A900

SERIES

SHEET

1 : 50

complex multi-part building, of different ages, meant passive house certification was not on the cards. “The new extension would perform to passive standard, but if you’re looking at the house as a whole, the previous extension would let it down.” Both Sampson and Horan remained interested in aesthetics throughout the design and build, so the environmental concerns, whether about energy use or embodied energy, could not be allowed to swamp everything. “Passive houses prefer south-facing windows but at the same time, you’ve still got to produce architecture. You can’t throw out architecture just because you’re doing passive house,” Sampson says. Making the house part of the landscape was something that was always a part of the plan. “The site has amazing views of the Burren, but [previously] the only way to enjoy them was to be outside. “In Ireland it’s especially important to bring in lots of daylight and connection to the outdoors. There’s no point in building a passive house and then having it so dark that you have to have the lights on all day.” As always, airtightness and thermal bridging were also crucial to the build. Sampson says the new extension was built to a passive house airtightness spec, but the building was tested a whole, and achieved an air permeability result of 3.39 m3/hr/m2. The use of glue-laminated timber for some key structural elements helped to avoid the use of steel, which acts as a thermal bridge that can transfer heat out of a building, as well as having a big carbon

REVISION SCALE AT A3

16/10/18 FIRST ISSUE DATE

REVISION DATE

PURPOSE Do not scale from drawing || Use figured dimensions only || Notify architect of all discrepancies || Read with relevant specification & consultant´s drawings || Print scale check, sheet outline = 287 X 410mm Drawing for planning purposes only, not for construction COPYRIGHT

Photography: Kelvin Gillmor

C

MILES SAMPSON B.ARCH

ph+ | case study | 47


footprint. “In this case, the guy who did the timber frame [Matthew O’Malley Timber Ltd] doesn’t use any steel so there was no thermal bridging. The builder Niall from GreenTec is excellent too. He really understands what low energy building is all about,” says Sampson. The windows are aluminium-clad timber units from True Windows, with the aluminium providing essential protection on the rain-battered west coast of Ireland. Sampson also says that in order to reduce the build time, the team decided to order the windows from the project drawings, rather than on-site measurements. “In this project that was a real challenge, because the link to the extension has two walls of glass windows with split levels floors and floor-to-ceiling windows.” Sampson

says it took tireless work and co-ordination between himself, the contractor, timber framer and window supplier to make sure it came off. Meanwhile Ecocel cellulose — made in Cork from recycled newspapers — was used for insulation of walls and roof in the new extension, both as it is a natural material and also because it acts as a carbon sink in its own right. “Primarily cellulose, recycled newspaper material, that’s what we prefer to use,” says Sampson. “The first thing is energy performance in building, but once you get that down the next thing to look at is the energy that goes into making the building. “We always like to use materials that are renewable, essentially, and carbon sequestering. It’s pretty much accepted that there’s way too much carbon in the

atmosphere, so every time you use material that contains it, you’re taking it out of the air: timber and cellulose do that well. “Cellulose starts as timber, which is turned into pulp, then paper, then it is recycled into insulation. Apart from being carbon sequestering it is also a recycled product.” The dwelling has three heat recovery ventilation systems, one for each of its main parts. The yoga studio had quite specific ventilation requirements: the system had to be large enough to provide fresh air for up to twelve people in a small space, while also being very quiet, with large fans running at low capacity. The main heating system is a Thermia air-to-water heat pump. “They used to have an oil-fired boiler and we took that out. There is underfloor heating in the cottage and the new extension, not that it’s needed, and in the existing extension, we connected up the existing radiators,” explains Sampson. The passive extension is equipped with temperature sensors, so the heating only comes on when needed — which his rarely — but there are no fancy controls in the old extension, simply the original thermostatic radiator valves. Future plans include solar PV, but of a particular kind — Tesla’s Solar Roof cells, which replace, and resemble, traditional roof slates. “As it’s an extension and not a new build, renewable energy wasn’t a requirement, but the client is very interested in PV. We’ve wired the house for the Tesla roof slates, but they’re not available yet in Europe,” says Sampson. In the end, Sampson might be satisfied with the project, but the clients are thrilled. Horan says that they now have a house that is beautiful, comfortable and offers stunning views in the new section — and a more cosy, traditional feel in the cottage. And yet, Horan says that the project almost didn’t happen, such were the family’s worries about what would be possible. “We knew that it would be difficult to combine the two existing buildings with a new extension in a way that would look right.” In the end, though, they got the house they wanted. “There’s a lot of houses around here with a barn, so it’s part of the inspiration, [but] both ends of the barrels are fully glazed,” he says. Most of all, it is, by design, a social space — both as a family home and as a business. “The house really, really works. It’s comfortable and the spaces, even though they are [in] different parts, it really works well, with everything close to the central staircase,” Horan says. “It’s easy to move through and connect with people.” For more on Keith & Amanda Horan’s meditation and yoga classes see www.beingmindful.ie and www.kinvarayogastudio.ie

48 | passivehouseplus.ie | Issue 28


CONSTRUCTION IN PROGRESS

1

2

3

4

5

6

1 The ground floor of the new extension features 250mm graphite enhanced EPS insulation under the 85mm GGBS concrete screed, and two courses of Quinn Lite thermal block at the base of the walls to minimise thermal bridging; 2 the use of glue-laminated timber for some structural elements, including the curved timber beams for the barrel roof, helped to avoid the use of steel; 3 the timber frame, by Matthew O’Malley Timber, features studs that were later insulated with cellulose insulation; 4 the True Windows timber alu-clad triple-glazed windows were ordered from drawings rather than on-site measurements to speed up the build, requiring exacting attention to detail; 5 Intello vapour control membrane fitted to the underside of the barrel roof, with service cavity to be installed underneath; 6 the final parts of the roof build-up, prior to installing the zinc roof cladding, are 20mm softwood treated boards, followed below by a ventilated cavity and Icopal breather membrane.

ph+ | case study | 49


Increase comfort. Reduce risk. Since 1969

CONCERNED ABOUT OVERHEATING RISKS?

www.murphyheating.com

Greenlite Energy Assessors specialise in the diagnosis, avoidance and resolution of overheating risks in low energy buildings, with a proven track record for providing accurate predictions of thermal behavior. An overheating analysis can: Improve occupancy comfort, wellbeing & productivity Reduce energy demand Inform design decision making Evaluate long term risks

For the widest choice in modern and traditional stoves

For information and impartial design advice, visit www.GreenliteEA.co.uk

Kinvara Co. Galway. Tel: 091 637159 www.murphyheating.com Since 1969

LCEA 159756

NATURALLY FEELING GOOD... Endura Delta®

Demand controlled ventilation system with heat recovery • • • • •

For residential buildings Controlled via the Endura Delta app Integrated humidity, CO2 & volatile organic compounds sensor Quiet and energy-efficient system Endura Delta 330 and 380 are Passive House certified, certificate for 450 pending

AerHaus Ltd

058 20005 info@aerhaus.com

www.aerhaus.com 50 | passivehouseplus.ie | Issue 28 IE_passive_house_190x135_0718.indd 1

www.renson.eu

22/06/18 14:17


SELECTED PROJECT DETAILS Clients: Keith & Amanda Horan Architect: Miles Sampson Contractor: GreenTec Building Energy consultant: Passive House Solutions Structural engineer: Charlotte Murphy Engineers Mechanical contractor: Western Energy Services Airtightness tester: 2eva.ie Timber frame: Matthew O’Malley Timber Airtightness products & sheep wool insulation: Ecological Building Systems Windows & doors: True Windows Cellulose insulation: Ecocel Thermal blocks: Quinn Building Products Ventilation: Aerhaus Heat pump: Ashgrove Renewables Stove: Murphy Heating Zinc roof cladding: GG Roofing Green roof: Larne Lough Nurseries Roof membrane: Renolit, via Laydex Kitchen & fitted furniture: Christian Vigurs Custom Furniture Stone: Liscannor Stone Wastewater treatment system: Kingspan Klargester

ph+ | case study | 51


It’s ALL Inside! EXHAUST AIR HEAT PUMP NIBE F730 No Outdoor Heat Pump Required An ideal solution for apartments & housing schemes Heating, Ventilation & Hot Water Inverter Compressor 1.1 to 6KW Remote Control & Monitoring by Uplink - Smartphone APP & PC Modular Construction - pre plumbed & pre wired

Erp Info In ready for Assessors - call 01 2864 888 or visit www.unipipe.ie

Builders - Just one machine & one trade required for Part L compliance! Developers - Lower build costs for apartments as no district heating required Double award winner at The Energy Show, Dublin 2016 52 | passivehouseplus.ie | Issue 28

www.unipipe.ie


IN DETAIL Building type: 424 square metre home, office & yoga studio. New passive-level timber frame extension to existing house, renovation of existing cottage. Previous timber frame extension had minor reconfigurations. Location: Doorus, Kinvara, Co. Galway Completion date: August 2017 Budget: Undisclosed Primary energy demand (DEAP): 60.63 kWh/m2/yr Energy performance coefficient (EPC): 0.443 Carbon performance coefficient (CPC): 0.476 BER: A3 (60.63 kWh/m2/yr) Airtightness (whole house): 3.39 m3/m2/hr at 50 Pa Thermal bridging: New extension is of timber frame construction with full fill cellulose insulation between studs, sitting on two courses of Quinn Lite blocks. No steelwork. Energy bills: Homeowners estimate an annual electricity bill for the first year in the house of €1,800, covering space heating, hot water and all electricity use for the home, office & yoga studio. Based on 21.43c/kWh and the running hours of the heat pump this includes circa €700/yr for space heating and circa €220 for domestic hot water, including immersion. Miles Sampson points out the space heating figure may be above average

as the building was still drying out, the heating system required commissioning, and 2017/18 was a particularly cold winter. Ground floor (new extension): Raft foundation insulated with 250mm graphite enhanced EPS insulation, 85mm GGBS concrete screed. U-value: 0.10 W/m2K WALLS New extension: Prefabricated timber frame with zinc or cement board cladding externally followed inside by ventilation cavity, 11mm OSB, 219mm cellulose filled timber studs, Intello vapour variable barrier/airtightness membrane, 50mm mineral wool filled service cavity, plasterboard. U-value: 0.19 W/m2K Cottage renovation: Existing rough stone wall, followed inside by existing foam filled drylining, 50mm sheep wool insulation fill between battens, Intello vapour variable barrier/airtightness membrane, 50mm sheep wool insulation filled service cavity, plasterboard. U-Value: 0.2 W/m2K ROOF New extension: VMZinc externally, followed inside by 20mm softwood treated boards, ventilated cavity, breather membrane, 11mm OSB, 319mm cellulose insulation between rafters, Intello vapour variable barrier/ airtightness membrane, 50mm mineral wool filled service cavity, plasterboard. U-Value: 0.15 W/m2K Extension link: Planted sedum mat and drainage tray, followed underneath by Renolit Alkorplan single ply roof membrane, 100mm PIR insulation, 18mm OSB, rafters, Intello vapour variable barrier/airtightness membrane, 22mm service cavity, plasterboard. U-Value: 0.16 W/m2K

Renovated cottage: Existing natural slates, followed underneath by existing insulated rafters, existing plasterboard, 200mm sheep wool insulation on new suspended ceiling, Intello vapour variable barrier/airtightness membrane, plasterboard. U-Value: 0.2 W/m2K Windows (extension): True Windows triple glazed aluclad timber windows with argon fill, low-e coating and warm edge spacer bars. Ug-value: 0.55 W/m2K, average U-Value: 1.00 W/m2K Heating system: Ashgrove Thermia iTec 16 air-to-water heat pump with COP of 4.21 distributing to underfloor heating throughout extension and renovated cottages and radiators in existing house. 79% efficient, Nordic Swan-certified Scan 68 wall-hung wood burning stove. VENTILATION New extension: Vents VUT 350 heat recovery ventilation system 85% efficiency. Old extension: Vents VUT 550 heat recovery ventilation system 81% efficiency. Renovated cottage (yoga space): Vents VUT 700 heat recovery ventilation system 81% efficiency oversized in order to minimise noise in the yoga space. Electricity: Wired to add PV solar slates to existing cottage roof when Tesla Solar Roof panels become available. Wired to add electrical car charging point. Green materials: Timber frame, glulam structural elements including curved glulam beam, Irish grown sedum mat for roof, cellulose recycled newspaper insulation, sheep wool insulation, GGBS cement.

ph+ | case study | 53


THE DEEPEST

GREEN EST

RETROFIT EVER?

Location Plan

North Point

The contractor must verify all dimensions on site before commencing any work or fabrication drawings. If this drawing exceeds the quantities taken in any way GTA North are to be informed before the work is initiated. Only figured dimensions are to be taken from this drawing. Do not scale off this drawing. Drawings are based on Ordnance Survey and / or existing record drawings - design and drawing content is subject to detailed Site Survey, Structural Survey, Site Investigations, Planning and Statutory Requirements and Approvals. Authorised reproduction from Ordnance Survey Map with permission of the Controller of Her Majesty’s Stationery Office. Crown Copyright reserved. GTA North Limited Copyright. Guy Taylor Associates Is a trading name of GTA North Limited. Drawing Notes:

With obsessive attention to preserving and restoring the original fabric of these two Victorian townhouses, and a commitment to shunning petrochemicals and using only natural materials, could this be the most wildly ambitious and sustainable passive retrofit ever undertaken in the UK?

Words by John Cradden

Front Elevation 1 : 50

Location Plan

North Point

The contractor must verify all dimensions on site before commencing any work or fabrication drawings. If this drawing exceeds the quantities taken in any way GTA North are to be informed before the work is initiated. Only figured dimensions are to be taken from this drawing. Do not scale off this drawing. Drawings are based on Ordnance Survey and / or existing record drawings - design and drawing content is subject to detailed Site Survey, Structural Survey, Site Investigations, Planning and Statutory Requirements and Approvals. Authorised reproduction from Ordnance Survey Map with permission of the Controller of Her Majesty’s Stationery Office. Crown Copyright reserved. GTA North Limited Copyright. Guy Taylor Associates Is a trading name of GTA North Limited. Drawing Notes:

Rev:

Description:

Revised By:

P1 Planning Issue P2 Revised elevation P3 Revised following planners P4 Balanced elevations

Issue Date:

UA UA UA UA

24.05.16 29.06.16 12.07.16 28.07.16

Project:

6&8 Zetland Road Chorlton Drawing Title:

Proposed Elevations Sheet 01 Scale:

1 : 50@A1

Original Drawn By: UA

Original Issue Date: Original Checked by:

Drawing Number:

Rear Elevation

Front Elevation

1 : 50

1 : 50

Planning

HQ Building, 2 Atherton Street, Manchester M3 3GS T: 0161 826 1042 M:07914 402 101 manchester@guytaylorassociates.co.uk www.guytaylorassociates.co.uk

Rev:

Description:

Revised By:

P1 Planning Issue P2 Revised elevation P3 Revised following planners P4 Balanced elevations

Issue Date:

UA UA UA UA

24.05.16 29.06.16 12.07.16 28.07.16

Project:

6&8 Zetland Road Chorlton Drawing Title:

Proposed Elevations Sheet 01 Scale:

1 : 50@A1

Original Drawn By: UA

Original Issue Date: Original Checked by:

Drawing Number:

Rear Elevation

Planning

1 : 50 HQ Building, 2 Atherton Street, Manchester M3 3GS T: 0161 826 1042 M:07914 402 101 manchester@guytaylorassociates.co.uk www.guytaylorassociates.co.uk

54 | passivehouseplus.ie | Issue 28

CR

Revision:

16-0001-21-103 Reason For Issue:

P4

CR

Revision:

16-0001-21-103 Reason For Issue:

P4


-£43 per year (estimated total energy costs)

Building: Deep ecological retrofit of two Victorian townhouses Location: Chorlton, Manchester Completed: Autumn/winter 2018 Final cost: £1.83m (estimate) Standard: Enerphit Plus

ph+ | case study | 55


WANT TO KNOW MORE? The digital version of this magazine includes access to exclusive galleries of architectural drawings. The digital magazine is available to subscribers on www.passive.ie

T

he leafy suburb of Chorlton seems like a fitting location for a passive house project that looks to have broken new ground in a number of exciting ways. Well known as the liberal heartland of Manchester, Chorlton is sometimes derided for being a bit too bohemian/lefty/middleclass for its own good, but if that’s the price to pay for being the location of what may well be the most sustainable passive house retrofit ever carried out on a period property, then so be it. A pair of semi-detached Victorian townhouses on Zetland Road in the soughtafter M21 postcode have been retrofitted not just to the Enerphit standard — the passive house benchmark for retrofit projects — but to Enerphit ‘Plus’, which is awarded to buildings that also generate at least 60 kilowatt hours in renewable energy each year per square metre of floor area. But besides being the first Enerphit Plus project in the world, its developer also took a vastly ambitious approach to reducing the overall carbon footprint and environmental

56 | passivehouseplus.ie | Issue 28

impact of the build. For a start, the building fabric contains practically no petrochemicals, all the materials and construction details are fully breathable, the dwellings still sit on their original footprints, and almost all 200 tonnes of brick in the property as well as all the original joists and rafters are still in place. “It’s keeping the embodied energy, the embodied carbon that was put in there when it was originally built… keeping that on site,” says its developer, Kit Knowles. Knowles was keen to take a fresh approach to the deep retrofit of a period property, where he says the usual passive retrofit strategy is to, “strip everything out from the inside, demolish bits that are hard to treat or get in the way, extend to accommodate a modern living format, send all the waste to landfill, then bring in new petrochemical fabric as a replacement.” And while this magazine has featured various projects over the years that roughly fit that description, many of which were important milestones in demonstrating


His philosophy was to make every layer in the walls, roof and floor highly breathable.

just how dramatically you can improve the thermal performance of historic dwellings, Knowles’s approach was markedly different. A chemical engineer by training, Knowles now runs Ecospheric, a consultancy specialising in sustainable construction, and which also supplies high performance timber windows. His CV includes stints with BP and pharma giant AstraZeneca but underpinning a lot of his work for those firms was a zeal for integration engineering. This, together with the fact that he comes from a family of architects (both his parents, a cousin and a sister) — who would frequently talk about how new energy-efficiency technologies were being “strapped” onto houses without any thought about how well they worked together — provided him with the initial spark to build an expertise in sustainable building.

Photography: Rick McCullagh

Green pioneer Ten years ago, Knowles and his wife Ellie deep retrofitted their own 100-year old Arts-and-Crafts style semi-detached home in Chorltonville into a ‘SuperHome’, a UK standard that requires homeowners to cut their dwelling’s carbon emissions by 60% (they achieved 81%) and then open its doors once a year to the public. Knowles says that the project was “kind of a laboratory”, featuring test-bed technologies like hybrid heat recovery with passive stack ventilation, the first use of Spacetherm aerogel external wall insulation, hybrid solar PV-thermal panels, and a solar-powered rainwater harvesting system. For this project, he was keen to focus on the type of domestic property categorised by the British government as ‘hard to treat’, which constitute around one third of the 24 million

homes in the UK. “The eight million pre-1930s dwellings became my bread and butter and was where I built up a lot of my knowledge base,” says Knowles, who closed his old consultancy two-and-a-half years ago and set up Ecospheric with the aim of producing, “exemplary pilot projects that set new standards, solved problems and filled the gaps in the built environment.” After an extensive search, Ecospheric bought Ingleside and Woodleigh in 2016, two adjoining semi-Ds on Zetland Road that were for sale as one unit. Built in 1894, the four-storey townhouses (including basements) were bought from a landlord’s portfolio and had been sub-divided into five separate apartments across the two buildings. They were in a poor state. Knowles says the firm initially wasn’t planning to go as far as it did with the project, but their confidence grew when the housing market started shifting strongly in an upward direction, prompting them to be more ambitious about the engineering behind it. The finished houses are stunning to look at, inside and out. The front façade looks suitably traditional, featuring what Knowles believes are the first stained glass external windows used in a passive house project. The windows were developed by Ecospheric Windows & Doors and their manufacturing partner, Viking, after extensive surveys of traditional stained-glass patterns in the area. At the west-facing timber-clad rear of the buildings, the first-floor windows are angled southward to maximise solar gains. In fact, the rear wall at ground floor level was the only external part of the building to be altered structurally, with the removal of the external brickwork. The large new glazed elements here left so little original brickwork behind that it was no longer structurally viable. Painstakingly upgraded fabric Knowles was conscious of the risk of overheating, but at Zetland Road the solution was to “keep the brick fully connected to the space within the property” in order to exploit its high thermal mass, that is, its ability to smooth out internal temperatures by absorbing and slowly releasing heat. So, on most internal walls the brickwork was simply parged with lime — which also provides thermal mass — and left exposed to the interior. Meanwhile, the exterior is clad in

ph+ | case study | 57


Organowood, a Swedish wood product distributed in the UK by sustainable wood specialists Ecochoice, which takes a novel, inert, approach to wood preservation: fossilisation. The patented system was developed based on the principle of biomimicry learning from nature – to eschew the use of synthetic chemicals by partially fossilising the timber. According to Mike Bekin of Ecochoice, Kit Knowles approached Ecochoice looking for a product that was low footprint in terms of a full cradle-tocradle approach – transport miles, durability, economics, chemical use, etc. “We see this as the successor to chemically-impregnated timber because the technology is virtually the same,” said Bekin, “but they’ve replaced the biocide heavy metal chemicals for inert silica which happens to be the second most abundant element on the planet.” Bekin explains that Organowood’s unique patent-protected process involves disolving the silica onto the wood, and then letting it harden once inside the wood. The rear façade also has rainwater goods and coping made of copper with a claimed 120-year lifespan, while a whopping 60 square metre array of solar photovoltaic panels on the roof generates an average annual output of 8,740 kWh. The walls of the houses are solid brick, and in places a second inner leaf of brick was removed. The side walls were externally insulated using Steico’s FSC-certified timber I-joists, which were insulated with cellulose, covered with wood-fibre, and finished in lime. The internal insulation to the front façade is again comprised of Steico’s timber I-joists, blown cellulose and wood-fibre board — but with a 38mm ventilated cavity between the old brickwork and the new insulated layer. Inside, the walls throughout the house were parged in lime and painted with Graphenstone paint, made from a combination of graphene and lime that claims to be truly crack-proof. The blackest art Describing construction’s fight against moisture ingress as the “blackest of black arts”, Knowles was keen to ensure that all the walls and construction details were genuinely breathable and diffusible. While a common approach in construction is to have a gradient of breathability across a wall, Knowles say this often results in an interior

CONSTRUCTION IN PROGRESS

1

2

1 The team preserved the original 175mm deep floor joists, which were insulated with cellulose, with Steico Protect Dry woodfibre insulation below the joists; and 2 an Intello or Siga airtightness and vapour control membrane above.

58 | passivehouseplus.ie | Issue 28

There’s this kind of acoustic quality about the space... like nothing else they’ve ever experienced.


layer that restricts the movement of moisture. His philosophy instead was to make every layer in the walls, roof and floor highly breathable all the way across, to support drying both inside and out, should any moisture get in. “Broadly speaking the long-term success of building fabric is dependent upon detailing, but even with perfect solutions on paper, faults will always occur during construction or during occupation. A much better approach is to design the fabric to dry quickly once wetted, a better form of redundancy.” He adds: “It’s impossible to stop water getting in. You can’t rely on your layers being absolutely perfect. It’s about making sure that any moisture that does get in there can readily dry out.” It may seem somewhat ironic that, for a project that aims to preserve as much of the building fabric as possible, Ecospheric ended up spending far more than it budgeted on the building fabric. However, part of this was clearly down to Zetland Road being a test-bed for a “breathable, organic, fabric-retaining solution” for passive house retrofits. “It was very uncompromising as a project,” Knowles says. “Although it’s not economic in its own right, it means that we’ve got the solutions moving forward.” Lime The first area of overspend concerned the bay windows, which needed new foundations, as the original Victorian ones were very shallow and not designed to last 125 years. So, after looking at a lot of different options, the team decided on a kind of aerated bench block system that uses just a fifth of the amount of concrete compared with traditional systems. Another area of overspend was in trying to hone the use of lime-based products. Knowles is a “massive fan” of lime, namely because of its breathability, ability to sequester volatile organic compounds and carbon, buffer moisture, and prevent mould build-up thanks to its alkalinity.

CONSTRUCTION IN PROGRESS

1

2

3

4

5

6

1 The Steico i-joist system installed here against the original brick wall of the front façade; 2 the need to preserve the building’s historic appearance posed numerous technical challenges, such as for sealing and installing a fan light above the entrance; 3 lime parging to the party walls; 4 construction of the rear facade, which features the Steico i-joist system with cellulose insulation and Organowood cladding externally; 5 installation of Viking triple-glazed timber windows into a layer of Steico Protect Dry wood fibre insulation on the side walls; 6 Adjoining the old brick party walls, the rear ground floor was the only part of the house where entirely new walls were constructed, again built from Steico’s i-joist system.

ph+ | case study | 59


80

70

35

65 10

Scale: 1 : 5 @ A1

70 80

CL Framing CL Wall

80

80

Fabricated flitch plate connection: 300 x 180 x 30mm thick base plate, holes to suit M16 bolts to proprietary thermal break, fabricated with Ex 540 x 140 x 10mm thick flitch plate with full penetration butt weld to base plate; 10 No. M20 bolts.

80

80

80

80 80

Soffit plate to RHS: 220 x 180 x 15mm thick holes to suit M16 bolts to proprietary thermal break. .

30 80 15

100

15

30

175

80

Proprietary thermal break unit by ‘Schock’. Base plate to RHS: 300 x 180 x 15mm thick, with holes to suit M16 bolts to proprietary thermal break.

15 40

140

40

140

Soffit plate to RHS: 300 x 180 x 15mm thick, with holes to suit M16 bolts to proprietary thermal break.

Detail 7

Detail 8

Detail

Scale: 1 : 10 @ A1

Scale: 1 : 10 @ A1

Scale: 1 : 10 @

above Isokorb thermal breaks at both ends of a steel beam, to prevent thermal bridging where the timber A-frame is to adjoin the steel.

60 | passivehouseplus.ie | Issue 28

Detail 3

Scale: 1 : 10 @ A1

M20 bolted connection formed with ‘interference fit’ holes for bolts to timbers and high tolerance holes to steel connection plating. Bolts shouldered as necessary (special order bolts) with oversize ‘Form G’ washers and nuts.

30

40

60 tbc

140

35

Base plate to PFC: 220 x 180 x 30mm thick, holes to suit M16 bolts to proprietary thermal break.

Base plate to RHS: 220 x 180 x 15mm thick, holes to suit M16 bolts to proprietary thermal break.

140

DE-011

Scale: 1 : 10 @ A1

Scale: 1 : 10 @ A1

Proprietary thermal break unit by ‘Schock’.

60 tbc

80 30

80

80

PFC built into / fixed into existing masonry. Fix with M12 stainless steel stud anchors at 450mm vertical centers, set with Hiliti HY270 resin to give 80mm embedment into brickwork. Set into bricks with 25mm minimum edge distance to brick edges (do not set into mortar joints).

80

Masonry re-built around steel.

CL Frame

6

70

100 nominal

80

Total silence & tranquillity Knowles particularly likes the “crisp room shapes” and the floors in Woodleigh, which are the original pitch pine floorboards painstakingly re-laid in a chevron pattern. But above all he likes the total silence and tranquillity that descends when you step inside and shut the door behind you. “It’s really bizarre and almost everybody who is shown around the property says that there’s this kind of acoustic quality about the space... like nothing else they’ve ever experienced. And Detail you’re 5 in a space where,

Fabricated flitch plate connection: 350 x 140 x 10mm thick cap plate, 4 No. M16 bolts to timber, fabricated with Ex 540 x 140 x 10mm thick flitch plate with 10 No. M20 bolts.

80

Scale: 1 : 10 @ A1

50

80

2 No. M16 bolts

250

Heavy duty strapping and blocking at 1200mm centers to each side of frame. Straps to be 1.0m long and fixed across 3 No. existing joists. Fix to all timbers (joists, blocking pieces and new timber frame members) with 2 No. 5.0mm diameter woodscrews x 50mm long into each timber element.

40

150 x 90 x 8 cap plate to post.

50

140

100 50

50 100 50 50 50 100 50

200

even if you get quite a lot of people, you get a crystal-clear conversation because there’s so much insulation and so much thermal mass that it’s just total sound absorption, which is rather unique.” Can these Zetland Road houses perhaps claim to be the greenest passive house retrofits to date in the UK, if not the world? Indeed, given their success in retaining as much as possible of the 125-year old carbon embodied in the buildings, surely Ecospheric could reasonably hold Woodleigh and Ingleside up to be among the most sustainable passive houses currently in existence, in Detail 2 terms of energy and materials? “I couldn’t make that claim without more evidence,” responds Knowles, but adds that he is working on a high-level carbon analysis that the firm hopes will help it make some meaningful comparisons in that regard. Having said that, he notes that while there are some amazingly green passive houses out there, they tend to be new-builds, they tend to be much smaller and still use a fair bit of concrete. “But for the time being all we’re really willing to say is we’re certainly, I think, the first petrochemical-free passive house retrofit. And I think we’re one of the few passive houses that have been kind of purist to its core in termsDetail of concrete reduction.” 6 65

Ex 450 x 350 x 8mm thick plate to face of timber (1 each face); steel shim plate (5mm thick) between timber and plate. 4 No. M16 bolts.

80

£925,000. The timing of this, not to mention budgets, restricted the extent of any continuous post-occupancy monitoring, which is currently fulfilled by a modest cloud-based temperature and humidity system. But Knowles says he is happy to facilitate any researchers eager to undertake more extensive study of the second property, Ingleside, which Ecospheric plan to use as its own office and show home. But being an Enerphit Plus, the energy bills for the properties should be practically zero (see ‘In detail’), and Ecospheric estimate Detail 1 that the water bills have been reduced from around £650 a year to £300.

140

However, the team spent long hours on site trying to achieve a finish with the lime that would have resembled the smooth gypsum plasterboards of the Victorian era. Knowles says that in the end, swapping lime products was the solution. “The natural fibres used for crack resistance and thermal advantage caused the issue. A cork lime solved the problem.” However, the use of graphene-enhanced lime paint should eliminate cracking in the finish, and Knowles says this will also greatly help with long term vapour control and airtightness. Meanwhile, Knowles is also proud of a solution he has developed that involves knocking out the front of a chimney, all the way up the three or four storeys of a typical Victorian building, to create a roomy cavity that houses all the services— including ventilation, heating and electrics. It means that the pipes for ventilation, for instance, can be much shorter than usual, improving overall performance and avoiding the need for exposed boxing, in keeping with the original Victorian interiors. In order to finance Ecospheric’s next project — a proposed zero waste and zero energy food hall in Levenshulme — Woodleigh is currently on the market for


CONSTRUCTION IN PROGRESS

We’re certainly, I think, the first petrochemical-free passive house retrofit.

1

2

SELECTED PROJECT DETAILS

3

4

5

6

7

8

Taping of 1 the Steico Special Dry wood fibre board used to insulate the roof externally and 2 the inside of the the roof build-up internally, which features an Intello membrane here; 3 the project pioneered a solution that involved using the old chimney cavities to duct services down through the buildings; 4 airtightness taping around ventilation duct where it penetrates the Steico wood fibre insulation; 5 sealing up of the chimney cavity after the installation of services like ventilation ducting; 6 construction of aerated concrete block bench system used to support the bay windows; 7 & 8 installation & finishing details of the Viking triple-glazed aluclad windows.

Developer, contractor, project manager, M&E engineer & passive house consultant: Ecospheric Architecture: Guy Taylor Associates and Ecospheric Civil & structural engineer: Studio One Consulting Passive house certifier: MEAD: Energy & Architectural Design Electrical contractor: Environmental Building Services Ltd Airtightness tester: Ritchie & Ritchie Airtightness contractor: Ecospheric and ColdProof Wall, roof & floor insulation & build system: Steico UK Thermal breaks: SchĂśck Ltd Airtightness products: Ecological Building Systems / Siga Windows & doors: Viking, via Ecospheric Windows & Doors Ltd Roof windows: Fakro, via JJ Roofing Supplies Organowood cladding: Ecochoice Ltd Kitchen fit-out: John George Fine Cabinetry Magply: IPP Ltd Roofing: SIG Roofing Permeable paving: Sudstech MVHR: Paul, via A+ Ventilation supplies Wood burning stove: Wiking, via Woodburner Warehouse Domestic hot water system: Mixergy Solar PV: Environmental Building Services Ltd Water saving toilets: Caroma, via Sanlamere Water saving fittings: Bristan, via Grahams Plumber Merchant Cast-iron bath: Cast Iron Bath Company Paint: Ecosphere, via the Graphene Company Heritage lime plaster: Mike Wye & Associates

ph+ | case study | 61


F WINDOW O ROO

IT H

U 8 T h e r m IT o

TT

F W

HE MARKET NT

THE WARMEST

WE KEEP THE WARMTH INSIDE

UN SING LE GLAZING

ROOF WINDOW FTT U8 Thermo The combination of innovations brought together in the manufacture of the FTT U8 Thermo roof window enables it to achieve a heat transfer coefficient Uw = 0.58W/m2K. This makes it by far the most energyefficient roof window with a single glazing unit on the market.

Distributed in Ireland by

62 | passivehouseplus.ie | Issue 28

FTT U8 Thermo window ensures: • lower heating bills – thicker frames and triple-chamber glazing unit • ease of operation and more space with the window open – higher pivot point • long-lasting performance – insulated flashing kit and Thermo flashing included as standard


ph+ | case study | 63


World’s leading trade fair HVAC + Water Frankfurt am Main, 11 – 15. 3. 2019

www.ish.messefrankfurt.com info@ireland.messefrankfurt.com Tel. +44 14 83 48 39 83

64 | passivehouseplus.ie | Issue 28

DU: 16.11.2018

Become a pioneer of digital heating solutions, automation and networked building systems technology.

68461-030_ISH_Technisch_Energy_Paasive_House_Plus_93x277 • FOGRA 39 • CMYK • js: 09.11.2018

ISH Energy High-tech – not conventional.

Irland

New sequence of days: Monday – Friday


IN DETAIL Building type​: ​Two Victorian semi-detached homes built in 1894, combined internal floor area of 374.3 square metres (187 square metres per house) Location: Zetland Road, Chorlton, Manchester Budget: ​£1.9 million Certification: Enerphit Plus certified (the two combined dwellings certified as one building, party wall not thermally insulated) Space heating demand (after): 12.5 kWh/m2/yr Heat load (after): 10.4 W/m2 Primary energy demand (after): 99.6 kWh/m2/yr Renewable energy demand: 41.6 kWh/m2/yr Heat loss form factor (PHPP): ​2.20 Overheating (PHPP): 0% Energy bills (estimate, per house): Total space heating demand of 2,346 kWh according to PHPP. This is to be met using a combination of wood burning stove & excess PV electricity to post heater in the MVHR system. Electricity demand of 2,039 kWh per year (PHPP). To be met from solar PV system & grid electricity. Hot Water of 1,864 kWh per year demand (PHPP). To be met from solar PV system & grid electricity. Biomass costs approximately £80 per cubic metre for unstacked logs. Assuming this amount is burnt each year, and each cubic metre provides 1,950 kWh (2,600 kWh burnt at 75% efficiency), remaining space heating demand after logs are burnt is 396 kWh, to be provided by electric post heater to MVHR system. Electricity consumption remaining for space heating, water heating & electrics is 4,299 kWh per year. The solar PV system generates 4,370 kwh per year, and assuming 80% utilisation & 20% export of this, the house uses 3,496 kWh solar electricity per year. This leaves 803 kWh per year required from the grid. The house’s Tonik renewable energy tariff is 12.68p per kWh plus a £73 standing charge, for an estimated annual electricity bill of £175. Adding the cost of biomass at £80, gives a

total annual energy bill of £255.

U-value: 0.108-0.148 W/m2​K

However, the house receives a renewable energy feed-in-tariff of £172 + £45 for 20% PV export to grid (£217). This leaves an annual energy bill of £37. In reality one cubic metre of wood could easily be sourced for free, which would leave an annual profit on energy costs of £43.

WINDOWS & DOORS Before: P ​ VC 1980’s double glazing. Overall approximate U-value: 3.0 W/m2​K

Airtightness​(at 50 Pascals): 0.9 ACH (working towards 0.6 currently) Please note there were 20 different U-values for opaque building elements on this project and the following are just some of the main elements. WALLS (AFTER) Front walls: Storm dry brick cream on 110mm Victorian facing brick externally, followed inside by 38mm cavity, 13mm Fermacell board, 145mm timber I-joists fully filled with Steico floc blown cellulose, 80mm Steico Protect Dry wood fibre insulation, 10mm Thermalime plaster. U-value: 0.175 W/m2​K Side walls: 14mm Thermalime render on 80mm Steico Protect Dry externally, followed inside by 240mm Steico floc blown cellulose between Steico I-joists, 250mm double layer of Victorian wire cut bricks with finger cavity, 10mm Thermalime plaster internally. U-value: 0.116 W/m2​K Rear walls (ground floor): Organowood cladding externally followed inside by 1mm façade membrane, 300mm timber I-joists fully filled with Steico floc blown cellulose, 1mm Proclima Intello or Siga membrane, 13mm gypsum plasterboard. U-value: 0.132 W/m2​K Rear walls (upper floors): Organowood cladding externally followed inside by 1mm façade membrane, 300mm timber I-joists fully filled with Steico floc blown cellulose, original nine-inch brick walls, lime plaster. U-value: 0.125 W/m2​K Floors (after): 22mm Reclaimed pine chevro with lime-based grouts & adhesives, followed below by 18mm Magply magnesium board, 1mm Proclima Intello or Siga membrane, 175mm Steico floc blown cellulose & floor joists, 80mm Steico protect dry. U-value: 0.165 W/m2​K Roof (after): Welsh slate externally on 50x35 battens/counter battens, followed underneath by 1mm breathable roofing membrane, 60mm Steico Special Dry wood fibre board, 145mm to 300mm timber I-joists fully filled with Steico floc blown cellulose, 75mm rafters fully filled with Steico floc blown cellulose, 1mm Pro Clima Intello or Siga membrane, 13mm gypsum plasterboard

After: Viking Windows AS SW14 & DK88 triple glazed timber windows: U-value of 0.68 W/m2​K (uninstalled), SW14 and DK88 doors: U-value of 0.72 W/m2​K (uninstalled) Roof windows: Fakro U8 thermally broken triple glazed roof windows with thermally broken timber frames. Overall U-value: 0.81 W/m2​K HEATING SYSTEM Before: ​Gas boilers and radiators After: 2 ​ kW electric post heater on Paul Novus 300 MVHR system, DiBT accredited Wiking log burning stove. Domestic hot water electrically heated in Mixergy 300L tank. Electricity fed from PV on roof. VENTILATION Before: N ​ o ventilation system. After: ​Paul Novus 300 heat recovery ventilation system. 93-94% heat recovery (PHI certified) Green materials: Wood fibre and cellulose (recycled newspaper) insulation; lime plaster/ render; timber frame hybrid construction; breathable magnesium construction boards; breathable flooring materials: Tuscan marble, hardwood; copper detailing for ultra-durable rainwater and coping goods; FSC certified hardwood cabinetry; Welsh slate kitchen worktops; CO2 absorbent lime-graphene paint by Graphenstone. Electricity: 60 square metre solar PV array across the two properties. Comprising 36 x 330-Watt Panasonic HIT modules over two systems. Each system being 18 modules, and with each module having a Tigo voltage optimiser connected to efficiently manage any shading effects, and to maximise the total output of the systems. The total installed capacity is 11.88kWp. Each 18-module system has been wired in two strings, one string of 11 modules (3.63kWp) and one string of 7 modules (2.31kWp). This configuration is to allow the later addition of on-site energy storage. A Solar IBoost water heater controller is also installed on each system. These controllers monitor the electricity consumption in the house and as soon as any of the PV generated electricity is not being used and begins to export, this PV electricity will be diverted into a circuit of choice. In Zetland Road this circuit of choice is an immersion heater in the hot water cylinder. As the two houses consume so little electrical energy, a large proportion of domestic hot water will be generated from using PV electricity.

ph+ | case study | 65


WANT TO KNOW MORE? The digital version of this magazine includes access to exclusive galleries of architectural drawings. The digital magazine is available to subscribers on www.passive.ie

ÂŁ77

per year for space heating & hot water (not including VAT or standing charges)

66 | passivehouseplus.ie | Issue 28

Building: 110 sqm detached mews house Location: South London Completed: November 2017 Budget: ÂŁ245,000 Standard: Passive house certified


A PASS IVE M E W S FIT FOR A PHYSIO

This beautifully designed passive house showcases some of the very best in contemporary urban architecture, responding thoughtfully to its historic surroundings while making ultra-intelligent use of space to create an airy, warm and light-filled home on a small mews site in South London.

Words by David W Smith

Ground Floor Ground PlanFloor Ground PlanFloor Plan

5

First FloorFirst PlanFloorFirst PlanFloor Plan

5

5

6 1

Roof PlanRoof PlanRoof Plan

1

1 4

4

6

66

4

8 3

2

2

3

3

7

7

7

7

7

7

8

8

2 6 9

1. Kitchen Bedroom 6. Bedroom6. Bedroom om 2. Livingroom Utility 3. Toilet/Utility Bathroom 7. Bathroom 7. Bathroom 4. Garage Plant Room 8. Plant Room 8. Plant Room Terrace 9. Terrace 9. Terrace age 5. Bin storage

6

6

1 Kitchen 2 Living Room 3 Toilet / Utility

9

6

6

9

4 Garage 5 Bin Storage 6 Bedroom

7 Bathroom 8 Plant Room 9 Terrace

0

1m 0

© RDA Archite ©

RDA Architects RDA Architects RDA Architects 16 Forest Hill Road,16 London ForestSE22 Hill Road, 0RR 16 London ForestSE22 Hill Road, 0RR London SE22 0RR +44 (0)20 8299 2222 +44 (0)20 8299 2222 +44 (0)20 8299 2222 info@rdauk.com info@rdauk.com info@rdauk.com

ors Architecture www.rdauk.com | Consultancy | Interiorswww.rdauk.com | Consultancy

www.rdauk.com

ph+ | case study | 67

Floo


E

lizabeth Sharp, one of the UK’s most renowned physiotherapists, was initially worried she would struggle to make the transition from a vast four-storey Georgian house to the small open-plan passive house she had built in her garden in South London. But the move proved surprisingly easy as she instantly enjoyed the new house’s more manageable space (110 square metres), passive house comfort, and lack of clutter. The judges of the Daily Telegraph’s Homebuilding and Renovating competition were equally enthusiastic, awarding it the North-West prize for the Best Green House 2018. It was also recently nominated for a Passivhaus Trust award. “It was a huge lifestyle change as I had always lived in old houses. I’d been in the Georgian house for 40 years and brought up my three sons there. I could also still see it out of the window, so I expected memories to come flooding back. But, to my immense surprise, I felt so comfortable in the new house I didn’t miss the old one at all,” she says. The reality was that Elizabeth, 76, had grown tired of living in such a large, uneconomical space. Although suitable for bringing up a family, it had always leaked energy and had-high South East bills. Elevation “The heating was just flying straight out the window and the entire top floor of the house was unused because I didn’t need the space. In my new house, my annual energy bills are around £300 and in summer I can RDA Architects Hill Road, London SE22 0RR windows at the front open the16+44Forest roof lights and (0)20 8299 2222 info@rdauk.com and back to create a lovely draught,” she Architecture | Interiors | Consultancy www.rdauk.com said. There was a great deal of relief when Elizabeth finally moved into the Mews house this year. The build was initially supposed to take a year but was delayed by four months when the building contractor went bust halfway through and had to be replaced at short notice. It was a worrying time as Elizabeth had taken out a bridging loan to cover the cost of the new house while

68 | passivehouseplus.ie | Issue 28

she tried to sell her old one. Fortunately, Elizabeth’s son Alexei, a former international decathlete, came up with a solution. He was already project managing the construction of the new house and he took the opportunity to set up his own construction company, then re-employ the team of Polish builders already working on the project. Everything fell into place. The project was completed, and Elizabeth found a buyer for her Georgian house. “I was anxious when I had to sack the contractor and I lost money over it but looking back I’m so happy here now that I forget the bad things and look to the future,” she says. Downsizing will enable Elizabeth to retire in comfort, but for now she is still clinical director of leading health, fitness and physiotherapy firm ESPH — together with her sons and co-directors Max and Alexei Sharp — and works mainly at EPSH Harley Street, the longest-serving physiotherapy practice on London’s medical mile. She’s worked with Arsenal football players, the stars of big London shows such as Cats and Midnight Express, and many well-known athletes. For 25 years, Elizabeth ran a physiotherapy business out of the basement of her old Georgian home, but eventually the workload became too large for the space and in 2007 the business moved to a 10,000 square foot Victorian property in East Dulwich, which was converted by RDA Architects into a complete fitness centre including a creche, large gym, physio rooms, Pilates studio and yoga facilities. But once the physio business had moved out, and her sons had grown up, Elizabeth no longer needed such a big house. However, she’d lived in the area for 40 years and wanted to stay local. She approached RDA again for advice on downsizing, because, she says, they had done a great job on her East Dulwich development. RDA chief Richard Dudzicki proposed a three-bedroom passive house on the site of the previous garage in the garden and promised her it would be warm, economical and full of light. She gave

North - East Elevation

South - West Elevation 0

1m

3m

© RDA Architects 2018

Elevations

The tight space required a lot of ingenious thinking.


the go-ahead on condition that she could include a hydrotherapy pool in the garden. It was RDA’s fourth certified passive house, and one of the others was actually a few doors down on the same street. But Elizabeth’s project presented certain challenges, including the difficulty of access to the Mews location, a tight budget of £245,000, and a restricted space of around five-by-eight metres. One by one, Dudzicki and his team found a way to resolve the issues. The tight space required a lot of ingenious thinking. Every component was designed to be “like the inside of an aircraft so it all fits neatly and has more than one function”. The stainlesssteel kitchen table, for example, slots into the kitchen units, and can be pulled out when dinner is served. The living room’s furniture was adapted from compact kitchen units, but it was custom-made. The television is hidden away and the space for the wheelie bins sits just outside the kitchen window, where it is invisible from the street. The house is also designed with an opening for a staircase lift. Meanwhile, the space under the stairs is used as a laundry room and the MVHR [mechanical ventilation with heat recovery] unit is tucked away in the cupboards at the top of the stairs. “Everything comes into one plant which acts as an essential node to shorten distances for all the duct work and save money. Lots of details were about saving on the budget as well as making the house as multi-functional as possible,” Dudzicki says. The deep plan necessitated more ingenuity to get enough light into the middle of the long and narrow house. At the front of the building the team placed a window that rises above ceiling height, bringing light into

Photography: Simon Maxwell & Timothy Soar

the depth of the room. In the middle of the building, they added a flat roof light above the stairs. Meanwhile, a light in the central bathroom brings in yet more sunlight. One of the loveliest design touches, which Elizabeth describes as her “gem”, is the pool in the garden. It is covered in decking, which slides open like a scene from Thunderbirds. “Everyone was aghast when I said I wanted the pool, including the architects. But exercise is so important to me as a physio and it’s the jewel in the crown for me. It’s an ‘endless pool’ with a jet stream, which allows me to convert a small space into what is effectively like an Olympic pool. It also has an in-water treadmill. It suits the style of the house perfectly,” she says. The electricity demand to power the pool is comfortably covered by the house’s solar PV array, and while the pool is heated electrically too, the architects insulated it heavily to minimise heat loss. The site’s inaccessibility posed further problems, though. The house sits on an unmade road that has two 90-degree bends. The Kingspan TEK structural insulated panels (SIPs) used to construct the walls and roof had to be brought down the laneway in vans because a larger lorry wouldn’t fit. RDA designed the panels to be no larger than three-by-two metres, so they could be transported more easily. Fortunately, some neighbours allowed the builders to use their car park and even take down a fence for access. Once the prefabricated panels arrived on site, the construction process was rapid. “It took around three months to put in the foundations, but then the house itself went up in three weeks. Using the SIPs panels, we put up the floors very quickly and the rest of the time was spent fitting it out

The architects also designed the house to run at a slightly hotter temperature than normal.

with cladding and putting the windows in,” says Dudzicki. Planning permission was achieved easily. But the planners insisted on a slightly industrial aesthetic in keeping with road’s historical use for back garages. Using bricks would have raised the budget, but the planners allowed Dudzicki’s team to stick 15mm brick slips onto the top of the panels. Designing with timber and aluminium for some parts of the house added to the industrial look. Off-street parking was not allowed so the architects designed a garage for an electric car complete with charging points. In keeping with the multi-functional style of the house, the garage can become an open courtyard when the panels are slid back. RDA trained the builders in passive house construction on site, including in the principles of airtight building. An early test air test showed great promise with an air permeability result of 0.54 (m3/hr/m2). Due to the unintentional use of an inferior airtightness tape around the windows, the house failed dramatically on its second test, but once the correct tape was installed the house scored 0.61 on its third test. On its final

ph+ | case study | 69


Everyone was aghast when I said I wanted the pool, including the architects. But exercise is so important to me as a physio.

70 | passivehouseplus.ie | Issue 28


20

110

367 172

SIP vapour barrier

15mm brick slip system

2x12.5mm plasterboard 110mm Kingspan K5 Insulation ceramic tiles

breather membrane

screed with underfloor heating

12.5mm Magnesium Oxide board

22

DPM

75

DPM

waterproof render

300

150mm insulation

907

lightweight blockwork

350

concrete slab

160

test, it achieved 0.43 (or 0.49 air changes per hour, better than the passive house standard of 0.6). The architects also designed the house to run at a slightly hotter temperature than normal. Rather than the normal 21C, they aimed for 23C because Elizabeth wanted a particularly warm home. At times over the scorching summer of 2018, the monitored temperature inside went up above 25C. On 22 and 23 July, it reached 27C in the house when the outside temperature was 35C, and 33C respectively. However, this was during a period when Elizabeth was away, the ventilation system was turned off, and windows were left closed. “It’s slightly above the curve for London temperature data for PHPP, but it’s still okay. Elizabeth likes to keep all the windows open in summer and she can do night-time cooling,” says Dudzicki. Elizabeth also wanted underfloor heating, fearing the house might not be warm enough in winter. She needn’t have worried. “They told me I would need no more than two radiators and I said, ‘you don’t know me, I really feel the cold’. I’ve not used it much but when there was snow and minus temperatures it was lovely to walk around barefoot on the warm ceramic and vinyl tiles,” she says. “It’s another of the many features I love about the house.”

clay heave board

0

©R

RDA Architects 16 Forest Hill Road, London SE22 0RR +44 (0)20 8299 2222 info@rdauk.com

Architecture | Interiors | Consultancy

5

Fou

www.rdauk.com

CONSTRUCTION IN PROGRESS

1

2

3

4

5

6

1 The mews lane, which has another certified passive house by RDA Architects a few doors down the street; 2 construction work begins on the foundations which took around three months to complete; 3 the house itself then went up in three weeks using Kingspan TEK structural insulated panels; 4 110mm Kingspan K5 Kooltherm external phenolic insulation board was fitted externally to the panels to further boost the U-value of the walls; 5 the house nearing completion; 6 adhesive applied to the insulation boards for adhering the 15mm brick slips to the wall.

ph+ | case study | 71


nZEB-Ready EPS Insulation Solutions nZEB-Ready EPS Insulation Solutions nZEB-Ready nZEB-ReadyEPS EPSInsulation InsulationSolutions Solutions nZEB-Ready EPS Insulation Solutions KORE Expanded Polystyrene has been nZEB-Ready EPS Insulation Solutions KORE KORE Expanded Expanded Polystyrene Polystyrene has has been been KORE Expanded Polystyrene has been in use for over 20 years, providing low in use use for for over over 20 years, years, providing providing low low KORE Expanded Polystyrene has been inin use for over 2020 years, providing low U-values and high thermal KORE Polystyrene has been U-values U-values and high high thermal thermal in use Expanded forand over 20 years, providing low U-values and high thermal performance as whole-home inperformance use for and over 20 providing low performance as as aa ayears, whole-home U-values high thermal performance as awhole-home whole-home insulation solution. insulation insulation solution. solution. U-values and high thermal performance as a whole-home

insulation solution. performance as a whole-home insulation solution. Delivering Delivering the the best best in technologically technologically Delivering the best inin technologically insulation solution. Delivering the best in technologically advanced advanced insulation insulation solutions, solutions, backed backed by by advanced insulation solutions, backed by Delivering the best in technologically insulation solutions, backed by aadvanced team ateam team of of experts experts providing providing personalised personalised aadvanced of experts providing personalised the bestproviding insolutions, technologically insulation backed by aDelivering team of experts personalised service service and and experience experience you you won’t won’t find find service and experience you won’t find a team of experts providing personalised advanced insulation solutions, backed service and experience you won’t find by anywhere anywhere else. else. anywhere else. service and experience you won’t find a team of experts providing personalised anywhere else. anywhere else. service and experience you won’t find Contact Contact usus today today and and see see how how wewe can can Contact us today and see how we can anywhere work work better, better, together. together. Contact uselse. today and see how we can work better, together. Contact us today and see how we can work better, together. Learn Learn more more atatwww.kore-system.com www.kore-system.com work better, together. Contact us today at andwww.kore-system.com see how we can Learn more Learn more at www.kore-system.com A product A product of of work better, together. Learn more at www.kore-system.com

Learn more at www.kore-system.com 72 | passivehouseplus.ie | Issue 28

PHP Advert PHP Advert 20181211 20181211 Updated.indd Updated.indd 2 2

A product of A product of A product of

2018-11-12 2018-11-12 8:27 AM 8:27 AM


SELECTED PROJECT DETAILS Client: Elizabeth Sharp Architect / M&E engineer: RDA Architects Build system supplier: Kingspan TEK Passive house certifier: MEAD Consulting Civil & structural engineer: Elite Designers Main contractor: CLC Build Quantity surveyor (preliminary advice): Burr & Neve MVHR system: Paul, via Green Building Store Airtightness test: EPS Group Insulation: Kingspan Insulation UK Airtightness products: Ecological Building Systems Windows & doors: Livingwood Windows Roof lights: Fakro Kitchen & storage: Comprex Roofing membrane: SIG Floor tiles: Feri & Masi Gas boiler: Vaillant Underfloor heating: Omnie Solar PV: Energy Cycle

A structural insulated panel (SIP) consists of a layer of insulation, usually a synthetic foam insulant, sandwiched between two layers of oriented strand board (OSB), providing both building structure and insulation in one prefabricated panel. Airtightness is typically measured in two ways: air changes per hour (ACH) or air permeability (m3/hr/m2). During a test a building is normally pressurised at 50 Pascals of pressure (50pa). ACH measures the number of times in an hour leaks in the building envelope allow its entire volume of air to be changed with external air. The passive house standard requires an ACH of 0.6 or less. Air permeability measures the volume of air (in metres cubed, m3) that can be pushed through gaps in one square metre of the building envelope per hour under pressure. For most typical houses the two figures are usually quite similar, but they start to diverge as building gets bigger, or if they have more complex shapes.

The judges of the Daily Telegraph’s Homebuilding and Renovating competition were equally enthusiastic, awarding it the prize for the Best Green House 2018.

ph+ | case study | 73


Mechanical Ventilation with Heat Recovery Systems Brink MVHR Systems are SAP Appendix Q listed, PHI certified and available in a range of capacities from 75-450m3/h.

Introducing the

Flair 325

Brinks quietest, most efficient and advanced machine to date.

Say goodbye to: • Mould, mildew and condensation • Stale, foul, unpleasant, humid air • Musty and unpleasant odours • High humidity levels

Say hello to: • Warm, freshly filtered air • Reduced asthma, hay fever and allergy triggers • Fewer drafts • Lower energy bills and emissions • Guaranteed, Dutch quality

Brink systems are also fully compatible with Ubbink’s Air Excellent air distribution systems. Air Excellent’s clever, push-together connection system combines unsurpassed ease of installation, with incredible levels of airtightness.

Learn more at www.BrinkHRV.com Brink and Ubbink are distributed throughout Ireland by Kernohan Distribution: Fir Trees, Greenway Industrial Estate, Conlig, Co. Down, Northern Ireland, BT23 7SU Crank House, Banagher, Co. Offaly, Ireland, R42 DE61 E: info@iakonline.com | W: www.iakonline.com or www.brinkhrv.com

74 | passivehouseplus.ie | Issue 28


IN DETAIL Building type: Detached 110 square metre mews house Location: Camberwell, London Completed: November 2017 Budget: £245,000 Space heating demand (PHPP): 15 kWh/m2/yr Heat load (PHPP): 9.5 W/m2 Heat loss form factor (PHPP): 3.97

water is £76.85 per year, not including VAT or standing charges, factoring in the heating demand (PHPP), floor area, boiler efficiency and an estimated gas price of 4.2c per kWh.

Thermapitch TP10 PIR insulation board, vapour control layer, 185mm void, 2 x 12.5mm Gyproc Wallboard, 3mm smooth plaster skim finish. U-value: 0.08 W/m2K

Ground floor: Ceramic tile finish, on 75mm screed with underfloor heating, on 300mm Kingspan Thermafloor TF70 PIR insulation board, on liquid applied damp proof membrane, on 350mm reinforced concrete slab, on 1,200-gauge polythene membrane, on Cellcore HXS 160mm, on 50mm binding to compacted hardcore base. U-value: 0.07 W/m2K

Windows & doors: Livingwood Windows

Airtightness (at 50 Pascals): 0.43 m3/hr/m2 or 0.49 air changes per hour

Walls: 15mm brick slips externally, followed inside by 110mm Kingspan K5 Kooltherm external phenolic insulation board, breather membrane, magnesium oxide board, 172 Kingspan TEK structural insulated panel system (comprising urethane insulation core sandwiched between two layers of OSB3), vapour control layer, 25mm service void, 2 x 12.5mm FireLine plasterboard, skim plaster finish. U-value: 0.075 W/m2K

Energy bills: Elizabeth’s estimate of her own combined annual heating & electricity bill is £300 per year. Passive House Plus’s estimate of her gas bill for heating & hot

Roof: Singly ply roof membrane externally, followed beneath by 18mm plywood decking, min 50mm void, 172 Kingspan TEK SIPs panel (as above), 120mm Kingspan

Overheating (PHPP): 5.8% Primary energy demand (PHPP): 48 kWh/m2/yr Energy performance certificate (EPC): A (90)

passive house 3k alu-clad triple glazed PHI certified windows. overall U-value: 0.66 W/ m2K. Also, Livingwood 14 passive house outward opening casement with overall U-value of 0.68 W/m2K. Bi-fold Door: Lacuna heat treated beech triple glazed bi-fold door; U-value: 0.95W/m2K. Livingwood Windows 3k alu-clad fully glazed entrance door; U-value: 0.72W/m²K Roof windows: Fakro U6 thermally broken triple glazed roof windows with thermally broken timber frames. Overall U-value: 0.81 W/m2K Heating system: Omnie underfloor heating system powered by a Vaillant Ecotec Pro 24 kW condensing gas combi boiler. Ventilation: Paul Focus 200 MVHR system, PHI certified heat recovery rate of 91% Electricity: 6.7m2 solar photovoltaic array with average annual output of 945 kWh/a

Observed Indoor Temperature vs Atmospheric Temperature 40.00

35.00

TEMPERATURE (°C)

30.00

25.00

20.00

15.00

10.00

5.00

0.00

Guests

Atmospheric Temperature Range (°C)

Vacant

Indoor Air Temperature (°C)

Overheating Level

ph+ | case study | 75


Photo: John Gomez

ICONIC

LO N D O N S C HEM E PI O N EE R S V E N T I L AT I O N - L E D R E T R O F I T Hundreds of flats at the Thamesmead estate in South East London were suffering from horrendous damp and mould. But an ambitious new project has aimed to fix these problems at their root, while demonstrating a fresh approach to making old social housing healthier and more comfortable for occupants.

Words by Kate de Selincourt

F

uel poverty is always miserable. But condensation, damp, and mould are among its most demoralising consequences. Mould is particularly horrible – and humiliating – to look at, and rightly makes its victims fear for theirs and their children’s health. Mould not only harms respiratory health, and may exacerbate allergic conditions like eczema, it also increases people’s risk of mental health disorders such as depression.1 Energy efficient building fabric has never been British construction’s strong point – and without abundant, affordable heating, homes of any era can be hard to keep warm and dry. But the damp and mould that had taken hold in some of the concrete housing on the extensive 1970s Thamesmead development east of London shocked even seasoned professionals. The striking brutalist architecture of the 2,500 flats and maisonettes around Southmere Lake has brought the development fame as a film and advertisement set. Still visited on architectural tours, the homes feature the angular profiles, broken massing, elevated walkways and cantilevered balconies

76 | passivehouseplus.ie | Issue 28

characteristic of the style. But the distinctive construction incorporates an epic array of structural and geometric thermal bridges. Originally the homes were served by an unmetered district heating system — if anything, the dwellings were too warm. They were however generally dry. But when the giant boilers reached the end of their working life 20-odd years ago, replacing the system was too expensive, so instead the previous landlord installed individual gas boilers. But as fuel prices rose, many households fell into fuel poverty. And with fuel poverty came condensation, damp and mould. Stock condition surveys suggested that by the time Peabody housing association took over the estate four years ago, almost one-fifth of the flats were affected. Some of the mould was “truly horrendous”, says Simon Jones of ventilation manufacturer Aereco, who has been working with Peabody and others on an ambitious new project to rehabilitate affected flats. “Some of the rooms just looked as if they had been painted black. Even the skylights were black,” he says. Energy consultant Peter Rickaby, who was brought in by Peabody to advise on how to

tackle the problems, says the mould was he the worst he has seen in 35 years. “It was just appalling. Quite a lot of households comprise single parents with small children, and the mums were scrubbing off the mould with bleach, then trying to keep their kids away from the bleach.” When the properties were taken over by Peabody, little had been done to improve them for a long time. However, the worst-affected dwellings had been mould-washed and redecorated, some of them time and again. In just one year 3,000 damp and mould-related “repairs” were logged, affecting 1,900 homes, with mould wash and redecoration costing £1,275 a time. Peabody wanted to sort out the problems at source. Large-scale regeneration is coming to Thamesmead, thanks to the imminent arrival of Crossrail (the Elizabeth Line). But the regeneration will be spread over years if not decades, so there are some homes – including some of those worst affected by mould and damp — which will not be not be replaced or improved for ten years or more. And as Peter Rickaby says, “you can’t leave people like this for ten years.”


Peabody’s objectives were to intervene more immediately to manage the condensation and mould — eliminating it where possible — and at the same time, mitigate fuel poverty. In order to work out what to do, Peter Rickaby and Peabody first had to assess the stock. They developed a scoring system to work out which dwellings were most at risk of condensation, damp and mould (CDM), based on each dwelling’s SAP score (the energy efficiency rating part of the energy performance certificate, or EPC), household income, number of occupants and previous reports of either CDM or excess cold. By visiting some properties and fine-tuning the scoring system, they found it could identify 95% of the properties suffering damp and mould. “Just about every home scoring as ‘high risk’ was really bad, many were not lettable,” says Rickaby. The next step was to design the interventions. The usual way of tackling fuel poverty is to increase affordable warmth – by improving heating systems, upgrading windows and doors, and insulating the fabric. But the heating systems at Thamesmead were already fairly modern, and most of the windows were already double-glazed. In order to improve the fabric performance, the solid walls would have to be externally insulated. But the complicated geometry — with pointed gables, balconies, walkways and piers — would have made this incredibly difficult. So, if they couldn’t insulate, what could be done? We are just beginning to understand that insulating buildings without ventilating at the same time is potentially risky. But how about ventilating without insulating, could that work? While it wouldn’t help to make people

Some of the rooms just looked as if they had been painted black.

living in fuel poverty any warmer, or save them money, might it still help them if their homes were easier to keep dry? Peter Rickaby thought it might. “Occupancy was one of the most powerful predictors of damp and mould. Higher occupancy implies higher moisture production, suggesting ventilation would be a worthwhile intervention,” he says. But with occupants in fuel poverty, wasn’t there a risk of exacerbating the situation by introducing cold air? “This was one reason why energy advice was going to be critical to the whole programme.” A three-tier programme was devised, depending on risk scores (see ‘Thamesmead condensation, damp & mould strategy’). At its heart was energy and moisture management advice, which was given to everyone. For those at medium risk there was the offer of smart thermostats, and a small number of boiler repairs, and for the high-risk dwellings, all this plus mould washes and the installation of mechanical ventilation. Ventilating right As Peter Rickaby explains, the so-called ‘system one’ ventilation in many of our homes — trickle vents and intermittent ventilation – can’t deal with CDM issues like those at

Thamesmead. “A lot of the mouldy homes had intermittent extract ventilation, but it was not doing its job, for the usual three reasons.” Namely, either it was inadequate, left unused because it was too noisy, or occupants were anxious about the energy costs, or it was broken. Rickaby and the team at Peabody were clear that continuous mechanical ventilation would be needed, in order to move enough air through the flats. Mechanical ventilation with heat recovery (MVHR) was one option, but despite its potential for comfortable and effective performance, it just wouldn’t have been practical to install. The solid concrete construction, and the presence of asbestos in some partitions, meant that running both supply and extract ducts throughout the flats would have been far too difficult. The team ended up plumping for continuous mechanical extract ventilation (MEV). But it would have to work. Research by ventilation expert Ian Mawditt and others has shown that many MEV installations fail to perform as they should, for the usual reasons – the fans are often underpowered, inlets are mis-installed, and systems get disabled by occupants, often because of noise. Peter Rickaby helped Peabody draw up a specification (see ‘Ventilation specification at Thamesmead), and it was a challenging one. The ventilation had to be effective – effective enough to remove moist air at one-and-a-half times the rate required by the building regulations, in order to deal with the highest flat occupancies. However, it should not over-ventilate the homes, as this would penalise occupants already in fuel poverty by wasting heat — so it needed to ramp down when not needed, or when occupancy was low.

1

2

3

4

5

6

1 & 2 Some of the flats at Thamesmead that were treated as part of the scheme; 3 - 6 Energy consultant Peter Rickaby says some of the flats were affected by the worst mould he had seen in 35 years, while Simon Jones of ventilation supplier Aereco said that, “some of the rooms just looked as if they had been painted black.”

ph+ | insight | 77


“A” RATED HOMEOWNER SOLUTIONS One of Ireland’s longest established insulation and airtightness contractors, at Usher Insulations we can take the hassle out of delivering any project to an A rating - or even an nZEB. Whether it’s a large housing scheme, high end house or retrofit, we have the expertise to help you deliver cost-effective, energy efficient buildings that are built to last.

CALL US NOW FOR A FREE QUOTATION ON

01 - 820 1921

Unit 102 Coolmine Ind. Estate, Clonsilla, Dublin 15 sales@usherinsulations.com www.usherinsulations.com

78 | passivehouseplus.ie | Issue 28


(above) Mould-free flats after the installation of new Aereco ventilation systems, which are seen here before and after boxing off and painting. “Most residents love the Aereco system as they don’t have to interact with it, it does the work by itself,” say energy advisor Peabody. There has been no recurrence of damp or mould reported to date.

It also had to be quiet. Ventilation can be as powerful as you like, but it is no use whatsoever if is turned off by occupants because it is too noisy. Buying air quality A system that didn’t deliver the specified air changes in practice would not sort out the CDM problems faced on the estate – and would effectively be a waste of everyone’s time and money. So, Peter Rickaby and the team at Peabody made a bold move. They turned the process for procuring the ventilation systems around, and based it not on paper compliance, but on real-world performance. As Rickaby explains: “We told our potential suppliers, ‘we are not buying a ventilation system from you, we are buying air quality. You have to guarantee that you are delivering this to us. We then required suppliers who were bidding for the contract to offer a live demonstration that their system would meet the specification.” And crucially, the contract would make them responsible for that performance of the ventilation systems when installed. The winning supplier would take ultimate responsibility for the system performance and had to make a commitment not just to sell fans, but to design the full systems, train and oversee the contractors, and guarantee the performance. Initial interest from half a dozen or so

No residents have experienced a recurrence of condensation, damp or mould.

suppliers was whittled down, and the contract went to Aereco, who were the only bidder to meet all the criteria. The Aereco system that was chosen ducts moist air to a centralised extract fan, and then out of the dwellings, with fresh air entering though moisture-sensitive inlets in living spaces and bedrooms. These inlets automatically adjust the flow rate of fresh air based on humidity in the flats. No fully decentralised systems were available that met the specification in terms of energy use, responsiveness and noise. Aereco’s Simon Jones recalls that the contractors were uncomfortable at first with the arrangement. “Contractors aren’t used to having their work signed off by the supplier before they are paid — it was very different from the usual arrangements.” But as he explains, once they had worked with this approach, they bought in fully and rose to the challenge. Jones says: “The spec required a proper team effort, and full buy in from all the supply chain. We worked very hard with the contractor, particularly on the acoustics, and they really got a hold of this. It can take nine months to get contractors familiar with the requirements, but NJS [the ventilation installer] and Vinci [the main contractor] got it very quickly, including devising their own pre-compliance checks before we came to test the installations.” Installation was not straightforward. Because of the solid concrete construction, drilling to run extract ducts though partitions, floors and ceilings was incredibly noisy and reverberated right though the block. Sometimes it was just too difficult, and routes were complicated by asbestos panels that had to remain undisturbed, so in some homes it ended up being cheaper and simpler to install two extract fans rather than one. Plywood boxes were built to contain the fans and ducts, all painted to match the décor of the flats.

Installing the supply vents was a lot easier: they were simply cut into the uPVC window frames. “Our demand-sensitive inlet vents look like normal vents really, just a bit bigger,” Simon Jones says. “You can ‘close’ them but there is always a minimum flow rate.” ‘Considerable success’ The first installations took place last winter, and to date 272 flats have been treated, with 264 of these getting new ventilation systems. It is becoming clear that the programme has had considerable success in achieving its objectives. Energy advisors Peabody have been following up with the households, and say “generally, everyone has been extremely happy with the works done,” and no residents have experienced a recurrence of condensation, damp or mould. “Most residents love the Aereco system as they don’t have to interact with it, it does the work by itself, and most residents have left the inlets on windows open fully to allow maximum ventilation. Some mentioned that the boxing [for the ducts and fans] was quite large but all agreed that the system had reduced the amount of moisture in their home, as they noticed after cooking and bathing.” While people aren’t generally saying that their homes feel warmer, “the majority say that their home feels more comfortable,” Peabody say. “On the energy advice visits I would talk about optimum heating controls, and draughtproofing, which could help with keeping the home warm – though some flats were already extremely warm.” The team are still early in the process of collecting data on residents’ energy use. Some residents have already reported noticeable bill savings, however. The hope is that costs will have fallen for many. Three-quarters of the residents were initially on expensive pre-payment meters, and many were helped to switch. As Peter

ph+ | insight | 79


livegreen_ad_lscape_188x130mm_fa.pdf

1

02/06/2016

14:17

C

M

Y

CM

MY

CY

CMY

K

In our case it’s trust. Because Passive House Plus is independently verified by ABC, our advertisers know they’re getting the exposure they’ve been promised. Our circulation is 7,343 for the period 01/07/17 to 30/06/18. ABC. See it. Believe it. Trust it.

WHAT’S IN A NUMBER? www.abc.org.uk

80 | passivehouseplus.ie | Issue 28


Rickaby recalls: “Nadira is absolutely brilliant. I went out with her on some home visits and saw how she was able to get people switched to a new tariff — then and there.” Some occupants also say they have turned down their thermostats, reducing wasteful heating ‘overshoots’. And no-one has asked for their ventilation system to be turned off, or disabled it themselves – again, suggesting that people are comfortable. ‘Dramatically improved indoor air’ With the help of the Switchee smart thermostats installed in some of the newly ventilated households, it has been possible to get a sense of how internal conditions have changed. While the timing of the programme prevented the collection of much “pre” data, it is clear moisture levels fell after the ventilation systems were installed (see Graph 1, p83). There has been significant behaviour change too, with three-quarters of occupants now reporting that they shut the bathroom doors, and dry their laundry outside when they can. “We have seen dramatically improved indoor air quality, particularly with regard to humidity,” Peter Rickaby told the conference of the Association for Environment Conscious Building in September. “Although we are not monitoring other pollutants, it is noticeable that the homes smell fresher, too.” Anecdotally, some occupants believe they have better health. One resident told Passive House Plus that her asthma was not so bad now her flat had ventilation, while another

(above) Some Peabody residents have reported energy savings, such as Mr Robinson, who claims he’s seen his heating costs fall by 30%.

told the energy advisor that in the past, her children would wake up in the night, and cough a lot, but since the works were completed they no longer cough. Perhaps the most distinctive feature of this project was the approach to the procurement of the ventilation. The professionals who worked with Peabody praised the association for grasping the need to for this radical approach. As Simon Jones put it: “Peabody were willing to set a robust spec, and had the courage to enforce it.” The result, says Peter Rickaby, is that “we have 100% compliance with not only Part F [of the building regulations, which deals with ventilation], but also our own, higher standards – which is very unusual, probably unique. And no-one has switched it off – again, really unusual.”

“It is rare for ventilation to be both unobtrusive and effective. Industry thinks they already have effective systems, but they get switched off, or they are ‘acoustically commissioned’ so the flow is too low. Either way they are not effective. It’s my challenge to industry — give us effective but quiet ventilation, quiet enough that it will be left on.” He’s also very happy that despite not being able to insulate people’s homes, their living conditions have got so much better. The usual approach to retrofit tends to be to upgrade the building fabric first, then do the heating and ventilation. But condensation damp and mould issues may be urgent, he points out. “If you are on a long-term stock programme and won’t get to affected properties for years or decades, we have shown there is benefit from intervening in the shorter term with a focus on ventilation.” “I was surprised in a way – I have always said that for households in fuel poverty, heating, ventilation and insulation all need doing, so my first concern was ‘is this going to work with no insulation?’” “We have increased the heat a bit, and added very effective ventilation. I think the occupants are still in fuel poverty, but we did get rid of the damp and mould. What I have learned from Thamesmead is that if you can put in good ventilation, so long as you can reduce fuel costs a bit, it goes a long way to tackling CDM problems. So, I’d say – don’t be deterred if you can’t manage insulation right away. You may still be able to make things better.”

1 The World Health Organization (WHO) found that extensive exposure to dampness and mould increased the chance of depression by 60 percent. (Cited by South-East Public Health Observatory, 2006 & Nottingham City Homes, 2016; Also, Harris J, Hall J, Meltzer H, Jenkins R, Oreszczyn, T & McManus S, 2010. Health, mental health and housing conditions in England. National Centre for Social Research: London)

Southmere Lake on the edge of Thamesmead

ph+ | insight | 81


100%

100%

IRISH

IRISH

HEATING SOLUTIONS

Firebird Enviroair Hybrid Heatpump, working with a Firebird oil or Gas Boiler. The natural Hybrid Combination. The perfect heating solution for the modern home - combining market leading technologies with over 35 years home heating experience. Unique Irish solution in achieving Part L Compliance. Constant, reliable, cost efficient heating 365 days a year - regardless of the temperature. Top of the range intelligent heating controls. Firebird Heating Solutions - a name you can trust.

ERP Rating

up to A+++

“Firebird heating solutions... first for innovation”

Contact our technical team for more information: Firebird Heating Solutions Ltd. Údarás Industrial Estate, Baile Mhic Íre, Co. Cork, P12 HK51, Ireland.

t: +353 (0)26 45253 e: info@firebird.ie www.firebird.ie

ENVIRONMENT

INNOVATION

TECHNOLOGY

Complete Electrical, Mechanical & Renewable Energy Solutions

Heat Pumps Underroor Heating Heat Recovery Ventilation Solar PV Panels

Unit 6, North Point Business Park, Blackpool, Co Cork

(021) 4308185 9.00AM - 5.30PM info@energywiseireland.ie

www.energywiseireland.ie

82 | passivehouseplus.ie | Issue 28


Vapour pressure differential: a better way to measure moisture? Vapour pressure differential is a neat ‘at a glance’ way to assess the effectiveness of a ventilation system — especially in a building where damp is a concern. The plot in Graph 2 shows the vapour pressure differential in the same dwelling as that of the relative humidity graph (Graph 1) whose ventilation was installed in February 2017. Vapour pressure, or absolute humidity, is the total amount of moisture held in the air. By contrast, relative humidity — the most common way humidity is measured — is a percentage of the maximum amount of moisture the air can hold at its current temperature. Vapour pressure will go up or down directly in response to moisture being added or removed from the space, independently of temperature. The relative humidity of outdoor air varies, but as long as it is cooler outside than inside, you can be pretty confident that the absolute humidity of outdoor air will be lower – which is what makes it possible to keep a dwelling dry by ventilating it. Graph 2 below, prepared for the Aereco team by ventilation researcher Ian Mawditt, displays the difference between

the absolute humidity in the outside air and that indoors. Moisture-generating activity adds moisture to the air, driving absolute humidity up, but with an effective ventilation system that moist air is displaced by a stream of drier outdoor air, so the difference between outside and inside cannot climb too high. The orange blobs, relating to the time after the ventilation was switched on, show how the absolute humidity of indoor air, as compared to outdoor air, was reduced. The installed ventilation was more effective in replacing moist indoor air with fresh outdoor air than the previous system (or, possibly, lack of system) – shown in blue blobs — had been. Plots of vapour pressure differential cut through the day-to-day ups and downs of relative humidity. Indoor relative humidity ranges up and down depending on the humidity of the outdoor air, indoor moisture production, and indoor temperature, while the vapour pressure differential varies with just one factor: how much of the moisture being added inside the dwelling is removed? And it is that factor that tells us if the ventilation is doing its job or not.

Thamesmead condensation, damp & mould strategy Lower-risk households: • Energy and heating advice, and help with tariff switching – at the start of the project 75% were on prepayment • Moisture management advice re clothes drying, closing doors to wet areas, putting lids on pans etc • 176 energy advice visits to date Medium-risk households: Advice as above, plus: • Smart thermostats installed in 163 households. According to the suppliers, Switchee: “By adjusting to occupancy patterns and local weather, the Switchee smart thermostat can reduce the amount of time the home is heated, thus saving energy, cutting CO2 emissions and reducing household bills”. The thermostat also feeds back information on indoor temperature and humidity to the landlord, flagging up households who may be falling into fuel poverty or at risk of condensation, damp and mould. Because of this data sharing element, some households declined the thermostats • Boiler replacement where the boiler was inefficient or faulty • A small number of dwellings had unfilled cavity walls, which were insulated

Graph 1

High risk households: Advice and interventions as above, plus: • Three-part anti-mould paint. Treated areas also received one coat of white emulsion and residents received a £40 DIY voucher per room treated. (261 households so far) • Installation of continuous, demand controlled, whole-house mechanical extract ventilation (264 households to date)

(Graph 1) A plot showing relative humidity in one dwelling before and after the installation of a ventilation system (in February). Humidity became more stable, with higher readings eliminated, suggesting that the ventilation was effective in controlling the moisture levels, as intended.

Ventilation specification at Thamesmead •

Graph 2

• • • •

Capable of delivering up to 150% of minimum ventilation rate in Part F (Approved Document F) of the building regulations To provide capability to deal with higher occupancy than Part F (Part F only assumes double occupancy in one bedroom) Demand-controlled Adjust ventilation rate accordingly between 35% and 65% relative humidity (and go at top speed above that) Ramps down when moisture levels are low, to reduce heat loss Quiet: 30 dBA at one metre’s distance

All doors were also to have 10mm undercuts to ensure air flowed through the whole dwelling

ph+ | insight | 83


COHOUSING & CO-LIVING I N T HE C O N T E X T O F C R I S I S If Ireland is to stand any chance of solving its housing crisis, innovative approaches may prove essential. Dr Karl Woods of Green Design Build and Green Party councillor & urban planning lecturer Ciarán Cuffe explore the role that cohousing and co-living could play.

A

ny effort to bring together a notion of shared space and housing is usually taken to be a radical experiment (‘intentional communities’), a transgressive act of folly (communal squatting) or, worse still, a utopian dream of repressive regimes (Soviet kommunalka). Cohousing is the exception to the rule. This is a loose term that encompasses everything from communal care homes for the elderly to the widely cited ‘Danish model’ of collective living – otherwise standard, owner-occupied, family dwellings clustered within common open space around a shared ‘community house’. The movement behind cohousing has existed for nearly half a century and the limited concrete results of its efforts can be found throughout continental Europe, the US and more recently the UK. Cohousing has generally received a very good press and is frequently lauded in academic circles, often uncritically, as a solution to range of social problems, including social isolation and loneliness, inadequate provision for elderly care, environmental destruction and, ultimately, as a bulwark against the corrosive effects of contemporary life upon that nebulous thing called ‘community’. Having gone through “one of the most catastrophic experiences of financial crisis in the developed world”, Ireland is now experiencing a housing shortage on a scale unparalleled in the history of the State. In this context, Irish media, housing bodies and local authorities have begun to consider unconventional solutions to the housing problem. Some in the national press have even suggested that “the Danish co-housing model could help solve Ireland’s crisis”. Here, cohousing is a relatively new phenomenon. There are two organisations in particular promoting the idea of the commons in housing, Cloughjordan Ecovillage in Tipperary and the Ó Cualann Cohousing Alliance based in Dublin. Though both groups have completed small-scale housing schemes, strictly speaking, nothing they have built to date could be

84 | passivehouseplus.ie | Issue 28

described as emulating the Danish model. And as the Irish housing crisis has progressed, both organisations have increasingly begun to question the utility of this model as a template for cohousing in Ireland. On the surface at least, the idea of sharing resources, space, utilities and amenities, would seem a sensible thing to do when housing is in short supply. However, some scepticism is warranted. Chiodellia and Baglione (2014) have remarked upon the all too apparent exclusivity and homogeneity of cohousing communities, highlighting the overlap that exists between these developments and gated communities. As with gated communities, cohousing societies are generally self-selecting residential groups occupying private space. And because the communal spaces and buildings they create are at an additional cost to the homes they build, the expense of living within these schemes can make them similarly exclusive. Thus one finds that most, if not all, cohousing developments in Europe and the US tend to be inhabited predominantly by well-educated, middle-class, middle-aged, white residents, people who are of necessity relatively wealthy. Of course, cohousing developments are not usually enclosed by gates and walls or protected by security guards. However, like most gated communities, they are usually distinct compounds, not fully integrated with their surroundings. Because Cloughjordan’s residents never constructed the kind of shared community house found in similar Danish settlements, they do not consider the Ecovillage a standard cohousing community. Yet it is still a communal settlement. Only one-third of the sixty-seven-acre Ecovillage site is given over to residential development, where 55 energy-efficient homes have been built so far. The rest of the site is used for communal activities, on a community farm, woodland, allotments and gardens. Professor Peadar Kirby, a local resident and a director of Sustainable Projects Ireland CLG

(SPIL), the non-profit company behind the Ecovillage, acknowledges that the model of housing upon which the scheme was originally based needs to adapt to better reflect the nature of housing demand in the present and to facilitate greater diversity within the community. SPIL was established in 1999, long before the present housing crisis. The primary motivation of its members was to establish a settlement capable of supporting a way of life that was more environmentally sustainable. While questions of affordability may have run beneath wider considerations of community resilience and the drive to grow membership, it would be fair to say that the delivery of affordable housing was not a principal aim of the organisation. Today, SPIL see the necessity for new members to self-build houses on the serviced plots it offers for sale as presenting a barrier to some who might otherwise join the community. Not everyone has the time, expertise or financial flexibility required to see a self-build housing project through to completion. A model structured around the sale of individual housing plots also makes it difficult for the community to diversify the types of tenure it can accommodate or to allow for the provision of social or affordable housing. Recently, SPIL has entered into discussions with the Ó Cualann Cohousing Alliance with a view to building and marketing properties it completes itself on sites within the Ecovillage. Together they are now planning to build 20 social and affordable housing units to provide accommodation not only for lower-income groups, but also for the elderly, people with disabilities and refugees. In 2017, the Ó Cualann Cohousing Alliance completed 49 terraced houses – a mix of two, three and four-bedroom units – in Poppintree, Ballymun, a predominantly low-income area dominated by social housing four miles outside Dublin city centre. Ó Cualann’s aim here was to provide affordable homes for middle-income households who were ineligible for State rent supplement but otherwise unable to purchase


Designed by architect Sven Markelius, the first collective residential building in Sweden was built in Stockholm in 1935. Markelius lived there himself for many years.

housing at market prices in the local area. It managed to reduce the sale price of the properties it built to roughly 30 percent below market value. It formed an alliance with Dublin City Council who provided the land at a fraction of the market price and waived all development levies, and it cut out the element of surplus a developer would normally receive, restricting profits to the building contractor and the commercial financing body alone. At first impression, it seems surprising that Ó Cualann, a cohousing group concerned with community diversity and communal living, would build its first development for owner-occupiers alone and create a scheme entirely without communal space or amenities. Hugh Brennan, CEO of the cooperative, explains that the group has adopted a phased approach to development and aims to build a community house during the next stage of construction when it will be providing an additional 28 houses and 11 apartments on an adjacent site at Cranogue Road in Ballymun. This will add to the overall cost of construction, but Brennan makes the point that the organisation’s aim is not simply to provide housing, but to build integrated communities. Creating diverse settlements with a mix of different tenures is also part of this vision. The cooperative, he says, made Poppintree an exclusively owner-occupancy scheme only because it agreed with Dublin City Council that the Ballymun area is presently insufficiently diverse, being dominated as it is by social rented housing. Other schemes Ó Cualann is involved in elsewhere do aim to provide housing for rental, such as at Ardmore in Waterford, and Limerick City. When considering affordable housing built for sale, some of the best-intentioned developments defeat their own purposes in the long run by failing to guard against the effects of commodification and price inflation. Inevitably, the fate that awaits any property within a cohousing development that can be

bought and sold on the open market without restriction is to become increasingly unaffordable through sale and resale, as has happened with local authority housing sold under the right to buy. One of the most notable, though least remarked aspects of the housing model Ó Cualann developed in Poppintree is the way in which it seeks to lessen the relentless pressure the market places on fully commodified housing. Residents who have purchased houses in the scheme have signed up to a clawback agreement that allows the local authority to capture a percentage of any appreciation in the value of the property if owners sell their homes within a ten-year period. Arguably, this kind of decommodification, whether partial or complete, is central to any long-term strategy for the provision of affordable housing at scale. Recognising this fact and promoting the not-so-popular idea of housing as a form of shelter rather than an asset, Ó Cualann have lengthened the duration of the clawback agreement that will apply in the next phase of their Ballymun development from ten to twenty years. When considering shared space and housing, the kind of clustered, owner-occupied dwellings that have been built in Irish cohousing settlements to date are by no means the only forms of cohousing in existence elsewhere. A group of collectively-minded Dutch citizens established a fifty-unit cohousing community in Hilversum in the mid-1970s called Centraal Wonen de Hilversum Meent. While the scheme as a whole is privately owned, and its layout is similar to the Danish model, the tenure of its residents is not. Its creators decided to fill it exclusively with tenants, because they wanted to make cohousing affordable to all. Sweden pioneered the concept of the ‘kollektivhus’, apartment complexes with smaller than usual private dwellings, a communal kitchen and other shared facilities, such as

cafeterias, laundries, crèches, workshops, gyms, etc. While some of these buildings are held in private ownership, many are publicly owned and managed and are occupied by tenants rather than home owners. The fact that cohousing can and does vary, in terms of ownership structure, resident tenure and day-to-day management, is not something that is widely recognised, even by national associations representing cohousing groups themselves. This is unfortunate because, whether public or private, institutionally owned forms of cohousing for social rental remove much of the risk of commodification and price inflation and make cohousing accessible to everyone, to people without access to finance and to people without the ability or time to directly manage a complex housing scheme. Furthermore, in contrast to typical Danish cohousing where shared space is created at a cost that is additional to the expense involved in building standard houses, the Swedish kollektivhus model demonstrates how collective living can be used to reduce the space requirements associated with standard dwellings and reduce rather than increase overall development costs. The only existing development in Ireland remotely resembling a Swedish kollektivhus is ‘Node Living’ on Pembroke Street in central Dublin. This scheme, marketed under the rubric of ‘co-living’, consists of 51 bed spaces rented separately but arranged within a series of apartments where all other living spaces are shared. Node was created by Anil Khera, a Canadian property developer and former regional director of a vulture fund who is clearly more concerned with turnover than togetherness. Here, the compression of domestic space that communal living allows has been used to broaden profit margins and enable the company to bring a new form of institutional rental accommodation to the market at a lower price than is standard for such a central location. The possibilities co-living opens for creating more affordable housing have not been missed by members of Cloughjordan Ecovillage or by the Ó Cualann Cohousing Alliance. Both are presently exploring opportunities to establish institutional co-living properties for rental as well as for sale, the former to accommodate the many overseas volunteers, interns and researchers who wish to reside in the Ecovillage on a medium-term basis, the latter to provide affordable housing for young people and the elderly, who can no longer afford to pay the increasingly exorbitant rents required to live in Limerick City. As non-profits, their vision of an alternative, Irish kollektivhus, is one where the benefits of lower development costs appear, not so much on their balance sheets, but in lower rents and better shared amenities as well as in the togetherness of future tenants and owners. Evidentially, both organisations have come to the conclusion that standard models of cohousing will not solve Ireland’s crisis, that more creative thinking regarding shared residential space is required than is offered by custom in either Ireland or Denmark.

ph+ | insight | 85


Marketplace News uPVC windows can be surprisingly eco-friendly — MBC Project

The uPVC Pixel window system from Oknoplast.

T

he environmental impact of uPVC windows can be substantially reduced through proper recycling at the end of life, according to MBC Project, the Irish supplier of windows and doors for low energy and passive house projects. “Generally people think that to be eco-friendly, when it comes to choosing windows, they have to choose timber or alu-clad — and it does give you the feeling that you’re getting eco-friendly materials, because they’re natural,” said Martin Labedz of MBC Project.

“But timber isn’t necessarily the most sustainable — it depends on how the forests that it comes from are managed.” “At the same time, people tend to think uPVC is the most ‘fake’ material — they think of plastic bags and plastic polluting the oceans and rivers, for example. But actually, thanks to the way PVC is made, it can be fully recycled at the end of its life, it just depends on what procedures the manufacturer has in place.” MBC Project supply the Oknoplast range of uPVC windows, which are based on

profiles from leading uPVC window profile manufacturer VEKA AG. “VEKA is the largest manufacturer of uPVC profiles for windows and doors in the world and one of the global leaders in uPVC recycling. They will happily take back windows built from their profiles at the end of life, and use them to remake new, more advanced modern profiles.” At VEKA’s plant at Behringen in the German state of Thuringia, the company now has two recycling lines with the capacity to recycle 50,000 tonnes of uPVC per year. MBC Project also supplies timber and aluminium windows, Labedz says, discussing the pros and cons of the various materials. “Wood is a high-end material, but its durability is worse than PVC or aluminium, particularly in Ireland where moisture is ever-present. So it’s important to look at how the timber is treated and protected, and how the profiles are bonded. While exposure can be reduced by cladding it with aluminium, the timber may still be affected by water vapour in the air.” “Aluminium offers the highest level of durability and structural ability. This means that the windows can be made in the largest dimensions and are least affected by the atmospheric conditions throughout their lifetime. It also offers the widest range of colours.” •

NIBE heat pumps chosen for Bolands Quay development

N

IBE’s F730 exhaust air heat pumps have been selected to provide heating, ventilation and hot water for the Bolands Quay apartment development at Grand Canal Dock in Dublin, which is currently under construction. The F730 provides heating, ventilation, heat recovery and hot water from a single fridge-like indoor unit. “The choice of these machines removes the need for centralised plant, distribution pipework and heat-meters etc, and provides for a standalone solution in each apartment without the need for outdoor units, which would have been functionally impossible, and unsightly on balconies,” said Paul O’Donnell, managing director of Unipipe, NIBE’s sole distributor in Ireland. “With smartphone styled user interfaces and remote control by the NIBE Uplink app, they are a great fit with these tech-sector apartments in the Google quarter.” Meanwhile, the NIBE F730 exhaust air heat pumps have also been selected for

86 | passivehouseplus.ie | Issue 28

NJ Doyne Construction’s A1-rated, nZEB development Clog Na Leinn in Collinstown Westmeath. O’Donnell said the selection of the NIBE F730 was seen as a very cost-effective solution as it provides ventilation, hot water and heating in one unit, meaning no separate MVHR system is required. The heat pumps at Clog Na Leinn are also integrated with 2.4kW NIBE solar PV roof panels, which are controlled by the heat pump. O’Donnell said this allows the effect of free incoming power from the solar panels to be multiplied by the heat pump. The solar PV system is completely integrated into — and available to monitor from — the heat pump’s controls, and via the NIBE Uplink app. O’Donnell continued: “The project architect Louis Peppard was really delighted that they have no outdoor machinery spoiling the appearance of his design. The first thirty homes range in size from 160 to 226 square metres and also feature Unipipe floor heating throughout. Louis also said it

was somewhat amusing to him to see that the only ‘chimneys’ on the development were putting out waste air at -15C instead of smoke!” For further information see www.nibe. eu and www.clognaleinn.ie. •

(above) An illustration of the Bolands Quay development, currently under construction at Grand Canal Dock.


VRM Tech aim to digitise passive house building

(above) Screenshots demonstrating how VCMP allows users to ensure the specified product, in this case Rockwool external insulation, is used on site.

V

RM Tech, the developer of innovative mobile software apps for the construction industry, has launched Virtual Construction Management Platform (VCMP), a cloud-based app that aims to radically streamline the management of construction projects. VCMP was developed as part of Built2Spec, an EU-funded project that sought to develop digital tools for better quality control of energy efficiency works on site, while integrating with the Passive House Institute’s certification platform. VCMP has a particular focus on energy efficiency and the building envelope, and is particularly targeted at large passive and nearly zero energy building (nZEB) projects. “All aspects of a project’s design and specification are fed into the platform at the start and can be easily communicated to everyone on site, with tasks assigned to particular individuals, and then quality checked by project managers upon completion,” said Neill Ryan of VRM Tech. “VCMP allows for a consistent approach to quality control, to get things right the first time, rather than snagging at the end. Compliance with buildings regs and all necessary documentation come pre-built in the system.” “Individuals on a project are also assigned specific skills, and must have the required skills to tick off an action. Once

a task is completed, it’s then fed into an approval cycle so those managing the project can approve it.” VCMP users can also specify products to be installed, and as these arrive to site, someone is assigned the task of entering product barcodes into VCMP to make sure no incorrect substitution occurs. The software was used on Durkan Residential’s Silken Park passive housing scheme in Citywest, Dublin, which averaged airtightness results of around 0.2 ACH. “Information and photographs from site are constantly being sent back to VCMP so project managers, designers, and architects can control quality.” Ryan also said that VCMP can be fully integrated with BIM. “It can take all of the information from the BIM model and allocate tasks — you can click on a wall in a room, for example, and see what tasks need to be done, and in what order, and those tasks can be assigned to specific individuals who tick them off as they go.” Ryan said the software should also make life easier for sub-contractors by digitally organising all the documentation they need on site. “Documents can be tracked fully all the way back to where they originated, providing a full audit trail.” For more information see www.built2spec-project.eu. •

Only choose the best airtightness products — Usher Insulations

L

eading insulation and airtightness contractor Usher Insulations has emphasised the importance of using reliable, quality airtightness products on site — to ensure that buildings remain air-sealed over their full lifetime, and not just for the day of their blower door test. Speaking to Passive House Plus, the company’s Andrew Usher said that Usher Insulations had tested 14 different airtightness systems over the years, but there were just three systems that the company now uses with complete confidence. “When one airtightness tape we tried was put under pressure during a blower door test, it just peeled away from the membrane,” he said. Usher added that the company now prefers to use Siga airtightness products for most of its projects. He emphasised Siga’s excellent reputation for reliability and durability — pointing to one installation of a Siga tape at the company’s own factory in Switzerland that has been in place for 30 years. “The range of products they have is excellent, and their Majrex membrane is also passive house certified,” he said. “The back-up service you get from Siga is also second to none,” he said. For more information see www. usherairtightness.ie. •

Advertise with us. To enquire about advertising, contact Jeff Colley on +353 (0)1 2107513 or email jeff@passivehouseplus.ie

www.passivehouseplus.ie

ph+ | marketplace news | 87


RAINSCREEN PANEL & SUBFRAME SYSTEMS

Nearly Zero Energy Building (nZEB) Concerned about the looming regulation? nZEB Compliant Minimal Heating Costs Cutting Edge Building Technology Passive Standard With our expertise, your dream home will become a reality.

T: +353 (0)21 439 5344 E: info@glavloc.com W: www.glavloc.com

88 | passivehouseplus.ie | Issue 28

WE HELP ARCHITECTS & BUILDERS: Achieve target u-values using either chi gaskets or standard isolators Select the most efficient system Provide thermal calculations Select materials that meet Passive House requirements, such as Parklex - Maintenance Free Timber walls, soffits, decking (pictured above)

info@elemental.ie

01 293 8951


Keystone’s Hi-therm+ Lintel receives BBA cert

Ecological scoop hat-trick of awards at Archi Expo

E

cological Building Systems scooped three awards at the recent Architecture & Building Expo held in the RDS, Dublin. This event brings together the country’s leading architects, architectural technologists, industry professionals and specifiers. The event runs in partnership with the annual Royal Institute of the Architects of Ireland (RIAI) conference. The three winning products from Ecological were: Diathonite Lime Screed — winner, interior product Diathonite Lime Screed is a thermal insulating screed consisting of cork lime (NHL 3.5), cork, clay, diatomaceous earth and binding agents. Diathonite screed is moisture vapour diffusion open (mu = 4), has a lambda value of 0.060W/m²K and boasts drying times up to 66% faster than typical cement or lime-based screeds. It can be used internally or externally on ground floor slabs, floors of non-heated rooms, suspended slabs and terraces.

(above) British Board of Agrément CEO Claire Curtis-Thomas (right) presents David Grace (left), sales director at Keystone Lintels, with BBA Certification for the Hi-therm+ Lintel.

K

eystone Lintels has received certification from the British Board of Agrément (BBA) for its Hi-therm+ Lintel. According to the company, this makes it the only BBA approved one-piece lintel solution which achieves the appendix R value for steel lintels in Part L 2013 (depending on wall construction). The Hi-therm+ Lintel is up to five times more thermally efficient than a standard steel cavity wall lintel, therefore reducing thermal bridging and improving SAP calculations. The BBA is one of the UK’s leading bodies offering approval, certification and test services to manufacturers of products and systems supplying the construction industry. Only products and systems that have passed a series of comprehensive assessments – including laboratory tests, on-site evaluations, quality management checks and inspections of production are awarded the certificate. BBA experts conducted assessments, audits and tests throughout the development of the Hi-therm+ Lintel to ensure it met their strict quality standards. The key factors assessed throughout the testing included structural performance, behaviour in relation to fire, thermal performance, condensation risk and durability. Products that receive BBA certification are recognised by building control, government departments, architects, specifiers and industry insurers such as the NHBC. The certification is seen as a mark of quality, safety and reliability. BBA certificates are awarded only to lintel companies who continuously carry out approved load testing and operate under strict quality control manufacturing procedures. David Grace, sales director at Keystone Lintels, commented: “We are delighted to have been awarded BBA Certification for our Hi-therm+ Lintel as it is a widely respected mark of quality assurance across the construction industry. At Keystone we invest heavily in research and development to continuously improve our products and deliver thermally efficient solutions. We have worked closely with the BBA throughout the development of Hi-therm+ to ensure we are providing our customers with innovative solutions which meet the highest quality and safety standards.” •

Diathonite Thermactive.037 – winner, renewable product Naturally sourced ingredients such as cork, diatomaceous earth and natural hydraulic lime are at the heart of Diathonite Thermactive.037 plaster, which offers breathability, thermal insulation and elasticity. Applying 45mm of Diathonite Thermactive to a solid wall improves the U-value from 2.26 W/m²K to 0.60 W/m², and offers the hygrothermal benefits expected with hydraulic lime-based materials. Thermactive.037 can be used both internally and externally, and provides a simple solution for thermal bridge mitigation. In addition, its antibacterial properties prevent the formation of mould and condensation and its high elasticity means the risk of cracks is significantly reduced. AURO Clay Paint – winner, renewable product AURO high-grade clay paint is the first ready-to-use paint on the market that has no preservatives. The clay paint is highly breathable and free from chemicals, oils and plastics. AURO provide full transparency, with every ingredient in AURO clay paint listed. It has also been rated as “very low-emission” product according to the AgBB evaluation scheme. Commenting on the awards, Niall Crosson, group technical manager with Ecological, said: “Receiving three awards highlights the acceptance and benefits of incorporating more natural breathable materials in retrofits and new builds… Diasen’s range of thermal plasters and screeds combined with AURO’s new range of clay paints provide the optimum combination of thermal refurbishment, enhanced comfort and health for the building envelope and homeowner.” For more information visit www.ecologicalbuildingsystems.com. •

(above) Pictured at the awards presentation are, from left to right: Maria Kiernan ( judge), Niall Crosson (Ecological), Peter Smith (Ecological), Klaus Unger ( judge) and Eleanor Heylin Kelly ( judge).

ph+ | marketplace news | 89


Daylight, embodied carbon & more: advances in the AECB PHribbon software Tim Martel of Optimal Retrofit describes recent advances in PHribbon, an Excel tool designed to improve the functionality of the passive house design software PHPP.

T

he AECB PHribbon — a set of tools for PHPP users — has grown, and some of the existing tools have been improved since September. PHribbon is designed to greatly speed up PHPP (the Passive House Planning Package) and add extra functions. Half the tools are for data entry (new build or retrofit) but now it also includes a daylight factor calculation, written by Mark Siddall of LEAP, and embodied CO2 calculations. It’s designed to make things easier and simpler, though it also has features for the most advanced users, and many of the buttons are designed to also work with Variants too – a tool developed by the Passive House Institute to enable designers to simultaneously model multiple design options. There is a dialogue for entering λ-values (also known as k-value or thermal conductivity) which are the building blocks of U-value calculations. To help get to the one you want quickly these have been grouped into category buttons. Pressing on one of these buttons shows just the items in that category. Three are by material type — ‘masonry’, ‘insulation’, and ‘other’. Another three are for special situations — ‘below DPC’, ‘Floor’ and ‘Roof’. Users can go directly to the BBA certificate to obtain λ90/90 values, if the product has one, or else a record of where the figure was from. BBA certificates are generally available for insulation materials and certifiers usually require them for certification. Users may like to have their own lists of λ-values because architects do have preferred and familiar construction methods, and the way people think and categorise things can vary. Therefore, a huge amount of flexibility is built in. There are three completely empty category lists for users to name and fill as their own. The

90 | passivehouseplus.ie | Issue 28

name they give appears on the button in the dialogue, replacing the one, two or three currently there. If that’s not enough they can also redefine three of the other buttons. Items can be in more than one category and the category can be changed. Users can add any number of their own materials. Many architects tend to re-use whole constructions in later projects, so why not make a library out of them that can be easily pasted in one go? In fact, why not make it really easy to grab U-value constructions from any PHPP that’s open? The U-value library does just that (and can include the effect of wall ties for retrofits, and variant options too.) The window tool, meanwhile, essentially allows complex windows to be defined by just four numbers. Now it has been extended so that it also writes all the main parts of the shading calculation too. This just means a few more options to the right of the dialogue. It also allows dimensions to be in mm or m, it will automatically detect which. A particularly neat feature is it writes figures as formulas, so you can change the dimensions of the window without having to redo the calculation. Clients love bright houses, but there can be a tendency to overdo the window-sizing when it’s not actually needed. Clients also don’t always think about the energy consequences of large windows. Generally, a good window will have a U-value about five times worse than a good wall, so the knock-on effect of windows that are all bigger than they have to be is expensive windows and more insulation to compensate. That’s why daylight factor calculations are really useful, they allow the designer to check, and adjust if necessary. Mark Siddall has put a great deal of time into perfecting his

daylight factor tool, a separate spreadsheet largely written using a button on the toolbar. It works to the relevant British Standard. Once results have been calculated these can be used to adjust the original window sizes. If windows have been put in with the window tool, then changing the dimensions of windows automatically adjusts all the shading figures (they are formulas) without having to redo them. Within the AECB there is interest in keeping embodied CO2 low, if possible, through the choice of materials. Calculations were done for three standard house types for the AECB Carbonlite retrofit course. Very similar calculations can now be easily done for any PHPP with a new button and corresponding materials library. In fact, the calculation can go much further than the original AECB ones. It now includes all parts of the construction, PV panels, pipes, ducting, cabling (not generally significant) and plumbing fixtures, yet can still be done in around 20 minutes. The passive house community is frequently open to sharing project information. It helps our sector grow, and it could save you time in your next project. The libraries of k-values, costs of items for retrofits (optional) and embodied carbon can be shared with other users through a central Google docs page set up for PHribbon users. Users can copy parts of their lists to the Google doc. Likewise other users can copy and paste into their own versions. As before, affordability is still a main concern, and therefore the software is modular. The basic new build tools are £45, and various options can be bought as modules as needed. Further information is available at www.optimalretrofit.co.uk/phribbon/ •


Sc

M me ulti nZ s n Un EB ow it RE on AD Sit he

Y

e

Insulated Concrete Forms - A Rated Structures

• High Performance REINFORCED CONCRETE Homes • A One Stop Solution that Easily Meets or Exceeds Building Regulations for Structure, Insulation, Sound Resistance, Fire, Airtightness and Thermal Bridging - all as standard, at no extra cost • New Amvic ICF 300 Form available now, offering o U-Value: 0.20W/m²K, o Y-Value: 0.02, o Air Permeability: <2m³/h.m² • Sound Resistance + 58DnTw. • Fully Certified and Approved • Cost Competitive, Rapid Build • For Self Build, Housing Schemes, Apartments, Commercial, etc.

Amvic Ireland

Unit 11 Rosemount Business Park Ballycoolin, Dublin 15 045 889276 www.amvicireland.com Made in Ireland I

PASSIVE HOUSE PERFORMANCE - TRADITIONAL BUILD COSTS ph+ | editor’s letter | 91


Our mission: Keeping Irish families warm this winter

Daikin’s next generation of air to water heat pumps Find out more at www.daikin.ie

92 | passivehouseplus.ie | Issue 21

Email: heating@daikin.ie


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.