General Arrangement Plan 0
1
2
3
Report any discrepancies to the Contract Administrator at once. This drawing is to be read with all relevant Architect's and Engineer's drawings and other relevant information.
N
1:100 5m
All dimensions to be verified on site by Main Contractor before the start of any shop drawings or work whatsoever either on their own behalf or that of sub-contractors.
© Ingleton Wood LLP
LEGEND:
9
DO NOT SCALE
Key: 8
10
circulation classroom cloakrooms
6
7
13
02 1010 x 2110
RWO
ED
01 1290 x 2625
W
03 1095 x 2625
3
W
W
04 5410 x 2625
05 5410 x 2625
B
WB
003 wc 6 m²
01 5410 x 2625
A
15 entrance matting
011 wc
IWB 007 classroom
ID
ID
08 1010 x 2110
06 1010 x 2110
W
W
06 1095 x 2625
WB
6 m²
IWB
E
60 m²
ID
009 classroom
E
22 1010 x 2110
60 m²
carpet
23 1010 x 2110
ID
carpet
non-slip vinyl
14 m²
ID
24 1010 x 2110
PB
wet area
wet area
B
PB
PB
001 classroom
09 1784 x 2110002 store
60 m² carpet
IWB
PB
10 1784 x 2110 006 store
ID
11 1010 x 2110
W
4 m²
PB
G 16 523 x 2625
H
15 523 x 2625
2 m²
026 wc
022 wc
2 m²
7 m²
7 m²
non-slip vinyl
carpet ID
027 ID store 30 2 m²1784 x 2110
ID
IWB
PB
19 1010 x 2110
12 m² barrier matting
ID
31 1010 x 2110
ID
ID
16 1010 x 2110
20 1010 x 2110
W
13 1135 x 2625
06 1300 x 2625
IWB
PB
PB WB
028 classroom
barrier matting
ID
32 1010 x 2110
ED
05 1804 x 2625
WB
60 m²
15 m²
IWB
W
FFL: 45450
9 PB
CW
02 5535 x 2625
06 2864 x 2625
W
14 3125 x 2625
5
7
11
12
CW
ID
01 5535 x 2625
34 1010 x 2110
3
MJ
W
15
12 1885 x 2625 RWO
2 1
18.03.16
Construction Issue Drawing -
PW
SF
Date:
Description:
Drw:
Chk:
Vision, form and function
16 m²
J
11 1885 x 2625
14
C0 Revision:
I
031 group W
13
H
10 1885 x 2625
33 3500 x 2110
WB
RWO
4 K L M
A
6
G
MJ
030 group
carpet
ID
ED
W
09 1885 x 2625
18 m²
wet area non-slip vinyl
ED
029 ciculation
ID
025 cloaks
barrier matting
J
F
028 1010 x 2110
2 m²
I
C
carpet
27 1784 x 2110
PB
non-slip vinyl
sheet vinyl
59 m²
01 018 001 1010 x 2110 intake
015 Room
29 1010 x 2110
non-slip vinyl
020 classroom
33 m²
02 017 1010 x 2110 cl. W
15 1784 x 2110
021 store
B
WB
ID ID
17 1010 x 2110
WB
non-slip vinyl
59 m²
2 m²
20 m²
PB
ID
PB
ID
024 group area PB
019 circulation
26 010 1784 x 2110 store
014 store
ID
W
RWO
wet area
PB
ID
ID
14 1010 x 2110
ID
PB
18 1062 x 2110
13 1010 x 2110
03 1010 x 2110
A
25 1010 x 2110
2 m²
ID
016 access
ID
21 1010 x 2110
2 m²
PB
16 1885 x 2625 MJ
W
non-slip vinyl
36 m²
ID
D
6 m²
08 5410 x 2625
wet area
023 circulation
2 m²
ID
PB
ID
ID
non-slip vinyl
04 1010 x 2110
013 wc
ID
non-slip vinyl
C
07 1095 x 2625
non-slip vinyl
05 1010 x 2110
WB
16
W
012 cloaks
ID
RWO
Movement Joint Locations MJ
03 1290 x 2625
13 m²
6 m² 004 ID cloaks 07 14 m² 1010 x 2110
W
14
ED
008 plant room
005 wc
02 1095 x 2625
toilets
RWO
entrance matting
2
stores
ED
A
1
12
B
5 4
plant
11
K L M
Colchester 874 The Crescent Colchester Business Park Colchester CO4 9YQ
Billericay Cambridge Colchester London Norwich Project:
T: 01206 224270 www.ingletonwood.co.uk
Roman Way First School Burns Road Royston Hertforshire, SG8 5EQ
Drawing Title:
General Arrangement Plan
16 Client:
RG Carter (Southern) Drawn:
Checked:
Date:
Scale:
SF
MC
18.03.16
1:100
Job No.:
Dwg No.:
Stage:
43203
201
Construction
Paper Size:
A2 Revision:
C0
General Arrangement Plan 0
1
2
3
Report any discrepancies to the Contract Administrator at once. This drawing is to be read with all relevant Architect's and Engineer's drawings and other relevant information.
N
1:100 5m
All dimensions to be verified on site by Main Contractor before the start of any shop drawings or work whatsoever either on their own behalf or that of sub-contractors.
Š Ingleton Wood LLP
LEGEND:
DO NOT SCALE
KEY: Fire Escape Route Secondary FireEscape Route FR30 Fire Resisting Wall FR60 Fire Resisting Wall Green fire break glass override box FD30S - 30 minute fire door with smoke seals
GENERAL NOTES All doors on fire escape routes to swing in direction of travel, with push bar / single motion release latch without key operation in the direction of escape. Final emergency light positions to be confirmed by M&E Contractor
F2
N3
N3
FIRE EXIT SIGNS Escape routes to be marked with emergency exit signs complying with:- the Health and Safety (Safety signs and signals) Regulations 1966 and conforming with BS 5499: Part 1 Fire safety signs, notices and graphic symbols, Specification for fire safety signs.
F2
Signs above doors and suspended signs to be mounted at 2.2m above FFL (unless stated otherwise), measured to the base of the sign. Signs sited on walls to be mounted between 1.7m and 2.0m, above FFL measured to the base of the sign. Signs to be sited at the same height throughout the escape route, so far as is reasonably practical.
N1
N1
N1
N1
F1
Fire Exit (Exit building from here)
F2
Fire Exit (Progress forward from here)
N1 N1
F2
F2
N3
N3
N1
FIRE NOTICES Fire doors shall be marked with the appropriate fire safety sign complying with BS 5499: Fire safety signs, notices and graphic symbols, Part 1 Specification for fire safety signs.
N1
N1
N1
N1
Fire door keep shut
N2
Fire door keep locked (Fixed one side only)
N3
Fire exit keep clear (Fixed to outside face of door)
Fire detection, emergency lighting and call points to be shown on Electrical Plans
N1 F1 N3 N1
F2
N1
FIRE EXIT
N2
N2
F2 Revision:
Date:
Description:
Drw:
Chk:
F2 N3
F1
N3 N3
FIRE EXIT
N1
Vision, form and function Colchester 874 The Crescent Colchester Business Park Colchester CO4 9YQ
Billericay Cambridge Colchester London Norwich Project:
T: 01206 224270 www.ingletonwood.co.uk
Roman Way First School Burns Road Royston Hertforshire, SG8 5EQ
Drawing Title:
Proposed Fire strategy Plan Client:
RG Carter (Southern) Drawn:
Checked:
Date:
Scale:
PW
SF
06.04.16
1:100
Job No.:
Dwg No.:
Stage:
43203
802
Construction
Paper Size:
A2 Revision:
-
Wall Types Details
All dimensions to be verified on site by Main Contractor before the start of any shop drawings or work whatsoever either on their own behalf or that of sub-contractors. Report any discrepancies to the Contract Administrator at once.
0
0.25
0.5
This drawing is to be read with all relevant Architect's and Engineer's drawings and other relevant information.
1:20 1.0m
Š Ingleton Wood LLP
LEGEND:
DO NOT SCALE
25mm Isover APR 1200 in cavity
25mm Isover APR 1200 in cavity 9mm thk. ply fixed back to metal studs both sides
70mm thk. GypWall classic (or similar approved) partition installed as per manufactures instructions.
2 No. layers of 15mm thk. SoundBloc plasterboard with skim coat finish both sides 146mm thk. GypWall classic (or similar approved) partition installed as per manufactures instructions.
2 No. layers of 15mm thk. plasterboard with skim coat finish both sides
146
9mm thk. ply fixed back to metal studs both sides
70
Key: Type Wall 'A'
Type Wall 'D'
Type Wall 'E'
Type Wall 'B'
Acoustic Value 58 Rw dB
Acoustic Value 47 Rw dB
Type Wall 'C' Acoustic Value 56 Rw dB Type Wall 'D' Acoustic Value 58 Rw dB Type Wall 'E' Acoustic Value 47 Rw dB
Full fill Rockwool 'Flexi' Insulation between infill system
SFS infill walling set between structural steelwork
9mm thk. WBP ply fixed back to SFS both sides
Breather membrane to outside face of ply sheathing
15mm thk. plasterboard with skim finish
Rainscreen Cladding: Trespa Meteon facade panels with TS200 bracket system with 85mm thk. rigid insulation fixed back to SFS
Full fill Rockwool 'Flexi' Insulation between infill system
SFS infill walling set between structural steelwork
9mm thk. WBP ply fixed back to SFS both sides
Breather membrane to outside face of ply sheathing
15mm thk. plasterboard with skim finish
Fair faced brickwork in common stretcher bond above DPC level
Steelwork to structural engineers design Vapour control layer to inside face of ply sheathing
Vapour control layer to inside face of ply sheathing
50mm Cavity
3No. layers of 25mm Isover APR 1200 in cavity
92mm thk. GypWall classic (or similar approved) partition installed as per manufactures instructions.
9mm thk. ply fixed back to metal studs both sides Revision:
15mm thk. plasterboard with skim coat finish 403
Date:
Description:
Drw:
Chk:
2 No. layers of 15mm thk. plasterboard with skim coat finish both sides Vision, form and function
391 92
Colchester 874 The Crescent Colchester Business Park Colchester CO4 9YQ
Billericay Cambridge Colchester London Norwich
T: 01206 224270 www.ingletonwood.co.uk
Project:
Type Wall 'A'
Type Wall 'B'
Tannery Drift First School Tannery Drift Royston Hertfordshire, SG8 5DE
Type Wall 'C' Acoustic Value 56 Rw dB
Drawing Title:
Wall Details Client:
RG Carter (Southern) Drawn:
Checked:
Date:
Scale:
SF
MC
09.03.16
1:20
Job No.:
Dwg No.:
Stage:
43204
702
Preliminary
Paper Size:
A2 Revision:
-