Portfolio patrycja was

Page 1






General Arrangement Plan 0

1

2

3

Report any discrepancies to the Contract Administrator at once. This drawing is to be read with all relevant Architect's and Engineer's drawings and other relevant information.

N

1:100 5m

All dimensions to be verified on site by Main Contractor before the start of any shop drawings or work whatsoever either on their own behalf or that of sub-contractors.

© Ingleton Wood LLP

LEGEND:

9

DO NOT SCALE

Key: 8

10

circulation classroom cloakrooms

6

7

13

02 1010 x 2110

RWO

ED

01 1290 x 2625

W

03 1095 x 2625

3

W

W

04 5410 x 2625

05 5410 x 2625

B

WB

003 wc 6 m²

01 5410 x 2625

A

15 entrance matting

011 wc

IWB 007 classroom

ID

ID

08 1010 x 2110

06 1010 x 2110

W

W

06 1095 x 2625

WB

6 m²

IWB

E

60 m²

ID

009 classroom

E

22 1010 x 2110

60 m²

carpet

23 1010 x 2110

ID

carpet

non-slip vinyl

14 m²

ID

24 1010 x 2110

PB

wet area

wet area

B

PB

PB

001 classroom

09 1784 x 2110002 store

60 m² carpet

IWB

PB

10 1784 x 2110 006 store

ID

11 1010 x 2110

W

4 m²

PB

G 16 523 x 2625

H

15 523 x 2625

2 m²

026 wc

022 wc

2 m²

7 m²

7 m²

non-slip vinyl

carpet ID

027 ID store 30 2 m²1784 x 2110

ID

IWB

PB

19 1010 x 2110

12 m² barrier matting

ID

31 1010 x 2110

ID

ID

16 1010 x 2110

20 1010 x 2110

W

13 1135 x 2625

06 1300 x 2625

IWB

PB

PB WB

028 classroom

barrier matting

ID

32 1010 x 2110

ED

05 1804 x 2625

WB

60 m²

15 m²

IWB

W

FFL: 45450

9 PB

CW

02 5535 x 2625

06 2864 x 2625

W

14 3125 x 2625

5

7

11

12

CW

ID

01 5535 x 2625

34 1010 x 2110

3

MJ

W

15

12 1885 x 2625 RWO

2 1

18.03.16

Construction Issue Drawing -

PW

SF

Date:

Description:

Drw:

Chk:

Vision, form and function

16 m²

J

11 1885 x 2625

14

C0 Revision:

I

031 group W

13

H

10 1885 x 2625

33 3500 x 2110

WB

RWO

4 K L M

A

6

G

MJ

030 group

carpet

ID

ED

W

09 1885 x 2625

18 m²

wet area non-slip vinyl

ED

029 ciculation

ID

025 cloaks

barrier matting

J

F

028 1010 x 2110

2 m²

I

C

carpet

27 1784 x 2110

PB

non-slip vinyl

sheet vinyl

59 m²

01 018 001 1010 x 2110 intake

015 Room

29 1010 x 2110

non-slip vinyl

020 classroom

33 m²

02 017 1010 x 2110 cl. W

15 1784 x 2110

021 store

B

WB

ID ID

17 1010 x 2110

WB

non-slip vinyl

59 m²

2 m²

20 m²

PB

ID

PB

ID

024 group area PB

019 circulation

26 010 1784 x 2110 store

014 store

ID

W

RWO

wet area

PB

ID

ID

14 1010 x 2110

ID

PB

18 1062 x 2110

13 1010 x 2110

03 1010 x 2110

A

25 1010 x 2110

2 m²

ID

016 access

ID

21 1010 x 2110

2 m²

PB

16 1885 x 2625 MJ

W

non-slip vinyl

36 m²

ID

D

6 m²

08 5410 x 2625

wet area

023 circulation

2 m²

ID

PB

ID

ID

non-slip vinyl

04 1010 x 2110

013 wc

ID

non-slip vinyl

C

07 1095 x 2625

non-slip vinyl

05 1010 x 2110

WB

16

W

012 cloaks

ID

RWO

Movement Joint Locations MJ

03 1290 x 2625

13 m²

6 m² 004 ID cloaks 07 14 m² 1010 x 2110

W

14

ED

008 plant room

005 wc

02 1095 x 2625

toilets

RWO

entrance matting

2

stores

ED

A

1

12

B

5 4

plant

11

K L M

Colchester 874 The Crescent Colchester Business Park Colchester CO4 9YQ

Billericay Cambridge Colchester London Norwich Project:

T: 01206 224270 www.ingletonwood.co.uk

Roman Way First School Burns Road Royston Hertforshire, SG8 5EQ

Drawing Title:

General Arrangement Plan

16 Client:

RG Carter (Southern) Drawn:

Checked:

Date:

Scale:

SF

MC

18.03.16

1:100

Job No.:

Dwg No.:

Stage:

43203

201

Construction

Paper Size:

A2 Revision:

C0


General Arrangement Plan 0

1

2

3

Report any discrepancies to the Contract Administrator at once. This drawing is to be read with all relevant Architect's and Engineer's drawings and other relevant information.

N

1:100 5m

All dimensions to be verified on site by Main Contractor before the start of any shop drawings or work whatsoever either on their own behalf or that of sub-contractors.

Š Ingleton Wood LLP

LEGEND:

DO NOT SCALE

KEY: Fire Escape Route Secondary FireEscape Route FR30 Fire Resisting Wall FR60 Fire Resisting Wall Green fire break glass override box FD30S - 30 minute fire door with smoke seals

GENERAL NOTES All doors on fire escape routes to swing in direction of travel, with push bar / single motion release latch without key operation in the direction of escape. Final emergency light positions to be confirmed by M&E Contractor

F2

N3

N3

FIRE EXIT SIGNS Escape routes to be marked with emergency exit signs complying with:- the Health and Safety (Safety signs and signals) Regulations 1966 and conforming with BS 5499: Part 1 Fire safety signs, notices and graphic symbols, Specification for fire safety signs.

F2

Signs above doors and suspended signs to be mounted at 2.2m above FFL (unless stated otherwise), measured to the base of the sign. Signs sited on walls to be mounted between 1.7m and 2.0m, above FFL measured to the base of the sign. Signs to be sited at the same height throughout the escape route, so far as is reasonably practical.

N1

N1

N1

N1

F1

Fire Exit (Exit building from here)

F2

Fire Exit (Progress forward from here)

N1 N1

F2

F2

N3

N3

N1

FIRE NOTICES Fire doors shall be marked with the appropriate fire safety sign complying with BS 5499: Fire safety signs, notices and graphic symbols, Part 1 Specification for fire safety signs.

N1

N1

N1

N1

Fire door keep shut

N2

Fire door keep locked (Fixed one side only)

N3

Fire exit keep clear (Fixed to outside face of door)

Fire detection, emergency lighting and call points to be shown on Electrical Plans

N1 F1 N3 N1

F2

N1

FIRE EXIT

N2

N2

F2 Revision:

Date:

Description:

Drw:

Chk:

F2 N3

F1

N3 N3

FIRE EXIT

N1

Vision, form and function Colchester 874 The Crescent Colchester Business Park Colchester CO4 9YQ

Billericay Cambridge Colchester London Norwich Project:

T: 01206 224270 www.ingletonwood.co.uk

Roman Way First School Burns Road Royston Hertforshire, SG8 5EQ

Drawing Title:

Proposed Fire strategy Plan Client:

RG Carter (Southern) Drawn:

Checked:

Date:

Scale:

PW

SF

06.04.16

1:100

Job No.:

Dwg No.:

Stage:

43203

802

Construction

Paper Size:

A2 Revision:

-


Wall Types Details

All dimensions to be verified on site by Main Contractor before the start of any shop drawings or work whatsoever either on their own behalf or that of sub-contractors. Report any discrepancies to the Contract Administrator at once.

0

0.25

0.5

This drawing is to be read with all relevant Architect's and Engineer's drawings and other relevant information.

1:20 1.0m

Š Ingleton Wood LLP

LEGEND:

DO NOT SCALE

25mm Isover APR 1200 in cavity

25mm Isover APR 1200 in cavity 9mm thk. ply fixed back to metal studs both sides

70mm thk. GypWall classic (or similar approved) partition installed as per manufactures instructions.

2 No. layers of 15mm thk. SoundBloc plasterboard with skim coat finish both sides 146mm thk. GypWall classic (or similar approved) partition installed as per manufactures instructions.

2 No. layers of 15mm thk. plasterboard with skim coat finish both sides

146

9mm thk. ply fixed back to metal studs both sides

70

Key: Type Wall 'A'

Type Wall 'D'

Type Wall 'E'

Type Wall 'B'

Acoustic Value 58 Rw dB

Acoustic Value 47 Rw dB

Type Wall 'C' Acoustic Value 56 Rw dB Type Wall 'D' Acoustic Value 58 Rw dB Type Wall 'E' Acoustic Value 47 Rw dB

Full fill Rockwool 'Flexi' Insulation between infill system

SFS infill walling set between structural steelwork

9mm thk. WBP ply fixed back to SFS both sides

Breather membrane to outside face of ply sheathing

15mm thk. plasterboard with skim finish

Rainscreen Cladding: Trespa Meteon facade panels with TS200 bracket system with 85mm thk. rigid insulation fixed back to SFS

Full fill Rockwool 'Flexi' Insulation between infill system

SFS infill walling set between structural steelwork

9mm thk. WBP ply fixed back to SFS both sides

Breather membrane to outside face of ply sheathing

15mm thk. plasterboard with skim finish

Fair faced brickwork in common stretcher bond above DPC level

Steelwork to structural engineers design Vapour control layer to inside face of ply sheathing

Vapour control layer to inside face of ply sheathing

50mm Cavity

3No. layers of 25mm Isover APR 1200 in cavity

92mm thk. GypWall classic (or similar approved) partition installed as per manufactures instructions.

9mm thk. ply fixed back to metal studs both sides Revision:

15mm thk. plasterboard with skim coat finish 403

Date:

Description:

Drw:

Chk:

2 No. layers of 15mm thk. plasterboard with skim coat finish both sides Vision, form and function

391 92

Colchester 874 The Crescent Colchester Business Park Colchester CO4 9YQ

Billericay Cambridge Colchester London Norwich

T: 01206 224270 www.ingletonwood.co.uk

Project:

Type Wall 'A'

Type Wall 'B'

Tannery Drift First School Tannery Drift Royston Hertfordshire, SG8 5DE

Type Wall 'C' Acoustic Value 56 Rw dB

Drawing Title:

Wall Details Client:

RG Carter (Southern) Drawn:

Checked:

Date:

Scale:

SF

MC

09.03.16

1:20

Job No.:

Dwg No.:

Stage:

43204

702

Preliminary

Paper Size:

A2 Revision:

-
































Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.