SPECIFICATIONS
dimensions / lamping
Construction Die-formed, pre-painted steel housing. Extruded aluminum fillers. Die-cast aluminum end caps. Highly specular aluminum end plates.
CLM9 (2) T5, T5HO
3” 6”
Shielding GrateOptic® curved, crenulated diffuser is extruded opal acrylic. Reflectors Die-formed, highly specular aluminum reflector with a minimum of 98% reflectance.
4’
3 5⁄8”
3 5⁄8”
8’
Finish Low gloss, white paint standard on fillers and end caps.
12’
Fixture Length 4’, 8’, and 12’ individual fixture sections for nominal suspension spacing of 4’, 8’ and 12’. Add 3 5⁄8” for each end cap to determine total fixture length. Using internal joiners, 4’, 8’ and 12’ sections can be joined to form longer length fixtures.
3 5⁄8”
CONFIGURATIONS Corner Assembly (Catalog No. CLM9 CNR)
performance
Notes: 1 “X” (Catalog No. CLM9 CNRX) and “T” (Catalog No. CLM9 CNRT) configurations are also available as standard options. Consult factory for special configurations.
CLM9 (2) T5HO
2 Photocell option available in endcap, tenon or corner assembly.
Tenon Assembly (Catalog No. CLM9 TNN)
90.1% Indirect 9.9% Direct 81.8% Efficiency For complete photometric data visit www.peerless-lighting.com.
Fixture
# of Lamps in Cross Section
CLM9
2
Emergency Type
Lamp Type
Shielding
28T5 54T5HO
COA Crenulated Opal Acrylic
Switching
Blank No Emergency SCT Single Circuit or Night Light DCT4,5 Dual Circuit ALC4,5 Alternate EL3 Emergency Battery Pack Lamping EC Emergency / Module Night Light Circuit Circuit EN3 Emergency Battery Pack with Night Light Circuit
Notes:
Nominal Row Length
Maximum Section Length
Voltage
Ballast Type
X FT Must be in 4’ increments
R4 R8 R12
120 277 347
GEB10 <10% THD Electronic S5 SIMPLY5™ 1,2 ADEZ Advance Mark 10 dimming ECO101 Lutron ECO-10 dimming OSDIM1,2 Osram 0-10v dimming Reference Ballast Chart on website or consult factory for other options.
# of Emergency Modules Blank No Blank NoEmergency Emergency 1SE 1 Section 1 Section 2SE 2 2Sections Sections XSE X XSections Sections
Lamp Color
Mounting Type
Overall Suspension Options
L/LP LP830 LP835 LP841
F1 T-Bar Ceiling (Universal Mounting Bracket) F1A T-Bar Ceiling (UMB with Integrated J-Box) F2 Hard Ceiling (Horizontal J-Box) F4A Grid Ceiling IDS 15⁄16” F4B Grid Ceiling IDS 9⁄16” F4C Grid Ceiling IDS Clip Screw Slot
12 12” overall suspension 15 15” overall suspension 18 18” overall suspension 21 21” overall suspension 24 24” overall suspension XX XX” overall suspension
No Lamp 3000K 80+ CRI 3500K 80+ CRI 4100K 80+ CRI
Available with T5: LP830P6 3000K 80+ CRI Premier LP835P6 3500K 80+ CRI Premier LP841P6 4100K 80+ CRI Premier Reference Lamp Chart on website or consult factory for other options.
1 Not available in 347 volt. 2 Not available with 28T5. 3 Option EL or EN (Battery Pack): a. is not permitted with dimming in the same row b. must be in the same section as the lamp being operated
c. is not permitted in a 4’ section d. is limited to one battery pack per section 4 For energy savings, in order to maintain the uniform, luminous aesthetic of the lens, SCT (Single Circuit) paired with dimming, Simply5™ or ALC (Alternate Lamping
ACG Adjustable Cable Grippers APF Alternate Power Feed (F4 mounting only) DL Damp Location Label DPC Daylight Photocell (consult factory) ELH EM through wire with separate feed ELS EM through wire with single feed GLR Fusing (fast blow) GMF Fusing (slow blow)
Module Circuit) is recommended over DCT (Dual Circuit). 5 DCT (Dual Circuit) and ALC (Alternate Lamping Module Circuit) are not available with dimming.
specifications
dimensions / lamping
Construction Die-formed, pre-painted steel recessed housing. Extruded aluminum surface mounted housing. Extruded aluminum fixedlength suspension yokes.
PLM9 (2) T5, T5HO (1) Lamp per diffuser 3”
Shielding GrateOptic® curved, crenulated diffuser is extruded opal acrylic with opaque painted ends. Reflectors Die-formed, specular aluminum reflectors.
3 1⁄2”
PLM9 G G Lay-in grid mount
1 1⁄2”
PLM9 S S Surface mount
17”
Finish Satin anodized finish on suspension yokes. Low gloss, white paint standard on surface mounted housing.
20” 23”
Fixture Length 4’ and 5’ individual fixture sections available. Overall fixture lengths are 4’ 9” and 5’ 9” respectively. Fixtures mount to 4’ grid or specify surface-mounted option. 17”
5 1⁄8”
performance
PLM9 (2) T5HO (1) Lamp (half of fixture shown) 89.1% Indirect 10.9% Direct 88.7% Efficiency For complete photometric data visit www.peerless-lighting.com.
# of Lamps in Cross Section
Fixture
Ceiling Type
PLM9
G Lay in grid 2 S Surface mount
Lamp Type
Nominal Row Length
28T5 54T5HO
U4 4’ U5 5’
Available for 5 FT: 80T5HO
Voltage
Ballast Type
120 277 3474
GEB10 < 10% THD Electronic GEB951,3 < 10% THD, .95 BF GEB1151,3 < 10% THD, 1.15 BF GEB802,3 < 10% THD, .80 BF GEB95S1,3 < 10% THD, .95 BF step dimming GEB80S2,3 < 10% THD, .80 BF step dimming GEB115S1,3 < 10% THD, 1.15 BF step dimming ECO103 Lutron ECO-10 dimming DMHL2,3 Lutron Hi Lume dimming OSDIM2,3 Osram 0-10V dimming Reference Ballast Chart on website or consult factory for other options.
Switching
Lamp Color
General Options
Mounting Options
SCT
L/LP LP830 LP835 LP841
DL Damp Location Label GLR Fusing (Fast Blow) GMF Fusing (Slow Blow) NYC New York City Code
CP Chicago Plenum
No Lamp 3000K 80+ CRI 3500K 80+ CRI 4100K 80+ CRI
Available with T5: LP830P 3000K 80+ CRI Premier LP835P 3500K 80+ CRI Premier LP841P 4100K 80+ CRI Premier Reference Lamp Chart on website or consult factory for other options. Notes:
1 28T5 only. 2 54T5HO only. 3 Not available in 347 volt. 4 54T5HO only. GEB10 ballast only.
specifications
dimensions / lamping
Construction Housing cover is manufactured from cold rolled steel. End caps are die-cast aluminum.
CLW9 (1) T5, T5HO
3”
Shielding GrateOptic® curved, crenulated diffuser is extruded opal acrylic. Shielding can be rotated to one of two positions, wall-facing or ceiling-facing.
5”
⁄4”
2’
Reflectors Die-formed, white, high reflectance aluminum reflector.
5 13⁄32”
1
3’
Finish Housing cover is painted white. Select white or painted aluminum finish for the joiner and end caps.
1
⁄4”
⁄4”
4’
1
8’
Fixture Length Individual fixture lengths in a single section are 2’, 3’, 4’ and 8’. For total fixture length, add 1⁄4” for each end cap. Using internal joiners, 2’, 3’, 4’ and 8’ sections can be joined to form longer length fixtures. Lenses are not continuous in a run or 8’ unit. The maximum lens length is 47 3⁄4” (for a 4’ unit). Lenses are separated by a 1 1⁄4” gap between lamp modules.
1
⁄4”
performance CLW9 (1) T5HO Wall-facing 53.6% Indirect 46.4% Direct 79.3% Efficiency
Polycarbonate dust cover fits securely in either position.
CLW9 (1) T5HO Ceiling-facing 88.8% Indirect 11.2% Direct 83.3% Efficiency For complete photometric data visit www.peerless-lighting.com.
Fixture
# of Lamps in Cross Section
CLW9
1
Lamp Type 28T5 54T5HO Available for 3 FT: 21T5 39T5HO
Lens is field-adjustable.
Nominal Row Length
Maximum Section Length
2 FT 3 FT 4 FT 8 FT X FT
R2 R3 R4 R8
Voltage
Ballast Type
120 277 347
GEB10 <10% THD Electronic S51 SIMPLY5™ ADEZ1,2 Advance Mark 10 dimming ECO101 Lutron ECO-10 dimming OSDIM1,2 Osram 0-10v dimming Reference Ballast Chart on website or consult factory for other options.
Available for 2 FT: 14T5 24T5HO
# of Emergency Modules
Emergency Type
Blank No Emergency Blank No Emergency or 1SE 1 Section Night Light 2SE 2 Sections EL1,3 Emergency Battery Pack XSE X Sections EC Emergency / Night Light Circuit EN1,3 Emergency Battery Pack with Night Light Circuit
Notes: 1 2 3 4
Switching
Lamp Color
End Finish
Options
SCT Single Circuit ALC4 Alternate Lamping Module Circuit
L/LP LP830 LP835 LP841
C110 Painted Aluminum Finish C041 White (Low Gloss)
DL Damp Location Label DU Dust Cover ELH EM through wire with separate feed ELS EM through wire with single feed ELS2 Normal feed w/ EM Separate Neutral GLR Fusing (fast blow) GMF Fusing (slow blow)
Not available in 347 volt. Not available with 28T5. Option EL or EN (Battery Pack) is not permitted in 2’, 3’, 4’ section. ALC (Alternate Lamping Module Circuit) is not available with dimming.
No Lamp 3000K 80+ CRI 3500K 80+ CRI 4100K 80+ CRI
Available with T5: LP830P 3000K 80+ CRI Premier LP835P 3500K 80+ CRI Premier LP841P 4100K 80+ CRI Premier Reference Lamp Chart on website or consult factory for other options.
10%
Cert no. SCS-COC-001047