Everyone Deserves Great Lighting
Students
Executives
Shoppers
Contractors
Teachers
Employees
Merchants
Architects
Librarians
Managers
Artists
Lighting Designers
Jocks and Geeks
Sales Teams
Prima Ballerinas
Building Owners
Everyone in Schools
Everyone in Offices
Everyone Everywhere
Everyone Like You
Degree Seekers
Captains of Industry
Patients
Interior Designers
Homecoming Queens
Receptionists
Scientists
Engineers
Administrators
Desk Jockeys
Civil Servants
Facility Managers
Janitors
Bean Counters
Dentists
Electricians
2
Great Lighting for All Walks of Life Whether in classrooms, cafeterias, labs, libraries and lecture halls. Or offices, boardrooms and conference centers. Or stores, lobbies and showrooms. Everyone who spends the majority of their day inside deserves great lighting. What is great lighting? It’s lighting with all the essentials: Modern Design
Efficient Performance
Comfortable Illumination
Energy-Saving Controls
Introducing Staple. All the fundamentals of great lighting accessible to all. Even that dorky IT guy down the hall.
Watch Video and Learn More at PeerlessLighting.com/Staple 3
4
Everyone Deserves...
Modern Design Subtle contours around the perimeter of the rectilinear body make Staple pleasingly approachable like Ms. Peach, your high-school principal. Its neutral (think Switzerland) form makes it suitable for a wide-range of installations. A soft glowing acrylic baffle or diffuse lens extends edge to edge and end to end creating seamless continuity. Gloss white paint finishes the understated yet thoroughly modern luminaire. FE AT U R E S
Luminous acrylic baffle or diffused lens shielding Suspended model with 1, 2 or 3 lamps (T8 or T5/T5HO) Wall-mount model with 1 or 2 lamps (T8 or T5/T5HO) 4, 8 or 12 ft. sections for individual units or continuous rows 5
6
Everyone Deserves...
Comfortable Illumination
Staple delivers on the Peerless mantra of
1000
Lighting for People® by emitting diffuse, uniform
500
and glare-free illumination. Optically engineered shielding and reflectors produce a quality of light that minimizes eyestrain and fatigue often experienced by those who spend significant time reading, writing, programming and
270
90
SPM4 2-LAMP T8 90.9% efficiency 9092 delivered lumens 67.4% up / 32.6% down
googling “sick day excuses.”
1000 500
With most lamping options meeting IES Recommended Practice for open offices (RP-1) and Collaborative for High Performance Schools (CHPS) guidelines, Staple produces exactly the kind of illumination that promotes workplace productivity and improves classroom learning.
270
90
SPM9 2-LAMP T8 91.7% efficiency 9170 delivered lumens 69.2% up / 30.8% down
7
Everyone Deserves...
90%+
Efficient Performance
To reduce electricity use, meet building power
the whole space with natural, even lighting. And it
density requirements and impress even the most
achieves this balancing act with minimal lumen loss;
miserly of energy misers, Staple directs lumens
Staple is more than 90% efficient.
exactly where they’re needed.
For applications where ceiling reflectivity is less
With a standard 65% indirect, 35% direct
than optimal, Staple may be specified with optional
distribution, Staple delivers the needed lumens
variable distribution reflectors to redirect more
on the work plane while effectively illuminating
light downward.
ce
ili n gh e ig ov er a ll h t su sp sp en ac sio in n g
(2) T8
10’
43fc / 42fc
ng
baffle / lens
pi
24’ 30’
la m
N
14’ 30’
8
2. 5 i l l u ‘ av g m .w in o an rk ce p l an e no r b o th w ar a d i ll w ll u h m ite in an ce no (m rth w ax al :m l u in) nif or m po it y (w wer /s de f ) ns it y
cl assroom applicatio n s
24”
14’
Collaborative for High Performance Schools (CHPS)
baffle / lens
baffle / lens
19fc / 21fc
1.4:1 / 1.4:1
35-50fc
15-20fc
<3.0:1
0.80
NOTES:
Calculation plane 3’ from walls White board plane 12’ x 4’ and 3’ off the floor
ns io g( n S ) m be ro f3 2’ 2. ro 5’ ws w av o g. rk ill u p l m ane in an ce ce i (mling ax un : m ifo in) rm it y po w (w er /s de f ) ns it y
pe
in
us
sp
nu
ac
ll s
ov e
ra
ce
40’
la m 32’
ili n
pi
ng
gh
e ig
ht
Ope n o ffice applicatio n s
baffle / lens
(1) T8
10’
21”
10’
6
31fc / 31fc
4.3:1 / 4.5:1
0.60
(1) T5
10’
21”
10’
6
37fc / 36fc
3.9:1 / 4.4:1
0.62
>30fc
<8.0:1
IES Recommended Practice-1
S
60’
baffle / lens
(2) T8
10’
24”
14’
4
44fc / 43fc
8.1:1 / 8.9:1
0.80
(2) T5
10’
24”
14’
4
49fc / 49fc
7.4:1 / 7.8:1
0.83
>30fc
<12.0:1
IES Recommended Practice-1
NOTES:
Furniture and partitions not considered in calculations
private o ffice applicatio n s
ty po (wwer /s de f ) ns i
un (miform ax it :m y in)
m ll u
ei ag er
av
m a illuxim m um in an ce
in
es
n
air
io
in
ns
m
lu
no
.o
f8
ft
pe
ht
us
ll s
e ig
ra
gh
baffle / lens
ov e
baffle / lens
ce
ili n
pi
ng 10’
la m
8’ 12’
an
ce
CALCULATION NOTES:
(2) T8
10’
18”
1
29fc / 28fc
42fc / 40fc
2.1:1 / 2.0:1
1.0
(2) T5
10’
18”
1
32fc / 31fc
46fc / 44fc
2.1:1 / 2.0:1
1.03
baffle / lens
2.5’ work plane
80/50/20 ceiling/walls/floor reflectance T8: 2850 lumen lamps, 30 input watts (1) T8, 60 input watts (2) T8 .69 LLF (light loss factor) includes: .95 LLD (lamp lumen depreciation), .88 LDD (luminaire dirt depreciation), .88 BF (ballast factor) .94 RSDD (room surface dirt depreciation) T5: 2900 lumen lamps, 31 input watts (1) T5, 62 input watts (2) T5 .79 LLF (light loss factor) includes: .95 LLD (lamp lumen depreciation), .88 LDD (luminaire dirt depreciation), 1.0 BF (ballast factor) .94 RSDD (room surface dirt depreciation)
99
10
Everyone Deserves...
Energy-Saving Controls When specified with an optional, integrated nLight® Micro Sensor, Staple becomes an intelligent Mr. Smarty Pants luminaire that provides: Daylight dimming Occupancy detection — dual technology passive infrared and Microphonics™ 360° coverage of up to 12’ depending on mounting height Remote or on-luminaire push-button programming For greater row, room, building or campus control, Staple can be specified as an nLight-enabled
®
TM
luminaire for easy, Cat-5e “plug-and-play” connectivity with nLight control and sensor systems.
Learn more about the nLight Micro Sensor at PeerlessLighting.com/nLight-Sensor-Page Created specifically with schools in mind, Staple can also be paired with either an nClass or Academy Pack pre-configured classroom controls package.
Learn more about these classroom solutions at PeerlessLighting.com/Classroom_Controls 11
Construction
Nominal 8 1⁄2” x 2 3⁄8” rectangular housing is formed from cold-rolled steel. Die-cast aluminum end caps are mechanically attached with no exposed fasteners. Reflectors
Formed, pre-finished white reflector standard. Shielding
SPM4: Injection molded acrylic baffle (opal diffuser optional). SPM9: Acrylic lens. Finish
White gloss powder paint comes standard. Custom colors available, consult factory. Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG fixture wires. For special circuiting or wire gauge, consult factory. Plug-in electrical connectors included. UL and C-UL listed. Luminaire Length
4’, 8’ and 12’ lengths in a single section for nominal suspension spacing of 4’, 8’ and 12’. For total luminaire length, add 1 1⁄8” for each end cap. Using internal joiners, 4’, 8’ and 12’ sections can be joined to form longer length luminaires. Installation Features
Y-hangers with adjustable cables come standard to simplify luminaire leveling across the width and length. Individual 4’, 8’ and 12’ luminaires can be ordered with end caps and power cords pre-installed and hanging hardware included in the luminaire packaging to reduce overall installation time (option IND). Packaging
Recycled cardboard box, folded cardboard cradles and kraft tape. Biodegradable protective luminaire bag.
12
STAPLE O R DE RI N G I N FO R M ATION SPM4 Baffle (1, 2, 3) T5, T5HO, T8
SPM9 Lens (1, 2, 3) T5, T5HO, T8 2 3⁄8”
2 3⁄8”
8 1⁄2”
8 1⁄2”
Luminaire # of Lamps in Lamp Type Cross Section SPM4 Baffle 1 SPM9 Lens 2 3
Example: SPM4 2 54T5HO WHR 40FT R12 277 GEB10 DCT LP835 F1/18 C032
Distribution (nominal)
Reflector
Shielding Luminaire Maximum Voltage (SPM4 only) Row Length Section Length
Ballast Type
# of Emergency Modules
WHR White reflector (Standard)
(Blank) None OPD Opal diffuser
GEB10 <10% THD Electronic OS5C* Osram Line or 0-10V (T8) ADEZ* Advance Mark 10 dim (T8, T5HO) ADZT* Advance Mark 7 0-10V dim DMHL3D* Lutron Hi-Lume dim OSDIM* Osram 0-10V dim (T5HO)
(Blank) None 1SE 1 section 2SE 2 sections XSE X sections
28T5 28W T5 (Blank) 65% up, 54T5HO 54W T5HO 35% down 32 32W T8 standard 40/60* 40% up, 60% down 20/80* 20% up, 80% down 0/100* 100% down CLI Center lamp isolator (Available with 3-lamp cross section only)
X FT 4’ increments
R4 4’ section(s) R8 8’ section(s) R12 12’ section(s)
120 277 347 (Not available with 28T5 lamps)
*Not available in 347V. Reference Ballast Wizard on website or consult factory for other options.
*Nominal distribution, refer to photometric test for exact distribution.
Emergency Type*
Switching
Lamp Color
Mounting Type
(Blank) None EC Emergency circuit EL Emergency battery pack (Not available in 347V) EN Emergency battery pack w/ night light circuit (Not available in 347V)
SCT Single circuit DCT Dual circuit
L/LP No lamp L/LPE No lamp. Wired for energy saving T8 lamps. LP830 3000K 80+ CRI LP835 3500K 80+ CRI LP841 4100K 80+ CRI
F1/
*EL and EC are installed in last 4’ of luminaire sections. Separate feed required unless ELS or ELS2 is specified.
Available with 28T5 only: LP830P 3000K 80+ CRI Premier LP835P 3500K 80+ CRI Premier LP841P 4100K 80+ CRI Premier Reference Lamp Chart on website or consult factory for other options.
/
T-bar ceiling (universal mounting bracket) F1A/ T-bar ceiling (UMB with integrated J-box) F2/ Hard ceiling (horizontal J-box) F4A/ IDS clip 15⁄16” tee F4B/ IDS clip 9⁄16” tee F4C/ IDS clip screw slot
Overall Finish Suspension*
Options
18 18” 24 24” 48 48” 72 72” 96 96” XX XX”
CP DL DU ELH ELS ELS2 GLR GMF IND
Overall suspension is measured from ceiling to bottom of luminaire. *Adjustable cable gripper comes standard
C032 White white (high gloss) C099 Custom finish
Chicago plenum (available with F1A only) Damp location label Dust cover (not available with 3-lamp T5HO cross section) Emergency through wiring w/separate feed Emergency through wiring w/single feed, shared neutral Emergency through wiring w/single feed, separate neutrals Fusing (fast blow) Fusing (slow blow) Individual luminaire (factory installed end caps and power cord, hanging hardware in box) MCS Matching feed canopy at support N100 nLight-Enabled (network ready with RJ45 connector on luminaire and 10’ of Cat-5e) NYC New York City code SLP Sloped ceiling (for 10-45°, must be specified along with F2, ACG and OJB options) XXXX Integrated sensor; see spec sheet to choose options and obtain code
13
Construction
Nominal 8 1⁄2” x 2 3⁄8” rectangular housing is formed from cold-rolled steel. Die-cast aluminum end caps are mechanically attached with no exposed fasteners. Reflectors
Formed, pre-finished white reflector standard. Shielding
SPW4: Injection molded acrylic baffle (opal diffuser optional). SPW9: Acrylic lens. Finish
White gloss powder paint comes standard. Custom colors available, consult factory. Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG fixture wires. For special circuiting or wire gauge, consult factory. Plug-in electrical connectors included. UL and C-UL listed. Luminaire Length
4’, 8’ and 12’ lengths in a single section. For total luminaire length, add 1 1⁄8” for each end cap. Using internal joiners, 4’, 8’ and 12’ sections can be joined to form longer length luminaires. Installation Feature
Individual 4’, 8’ and 12’ luminaires can be ordered with end caps pre-installed and wall-mount hardware included in the luminaire packaging to reduce overall installation time (option IND). Packaging
Recycled cardboard box, folded cardboard cradles and kraft tape. Biodegradable protective luminaire bag.
14
STAPLE WALL O R DE RI N G I N FO R M ATION SPW4 Baffle (1, 2) T5, T5HO, T8
SPW9 LensSPW4 2 T8 (1, 2) T5, T5HO, T8 2 3⁄8”
1”
2 3⁄8”
8 1⁄2”2 T8 SPW4
1”
8 1⁄22” T8 SPW9 Example: SPW9 1 28T5 WHR 40FT R12 120 GEB10 1SE EC SCT L/LP C032 DL
Luminaire # of Lamps in Lamp Type Cross Section SPW4 Baffle SPW9 1 SPW9 Lens 2
2 T8
28T5 54T5HO 32
28W T5 54W T5HO 32W T8
Reflector
Shielding Luminaire Maximum (SPM4 only) Row Length Section Length
Voltage Ballast Type
WHR White reflector (Standard)
(Blank) None OPD Opal diffuser
120 277 347
X FT 4’ increments
R4 R8 R12
4’ section(s) 8’ section(s) 12’ section(s)
GEB10 <10% THD Electronic OS5C* Osram Line or 0-10V (T8) ADEZ* Advance Mark 10 dim (T8, T5HO) ADZT* Advance Mark 7 0-10V dim DMHL3D* Lutron Hi-Lume dim OSDIM* Osram 0-10V dim (T5HO)
# of Emergency Modules (Blank) None 1SE 1 section 2SE 2 sections XSE X sections
*Not available in 347V. Reference Ballast Wizard on website or consult factory for other options.
Emergency Type*
Switching
Lamp Color
Finish
Options
(Blank) None EC Emergency circuit EL Emergency battery pack (Not available in 347V) EN Emergency battery pack w/night light circuit (Not available in 347V)
SCT DCT
L/LP No lamp L/LPE No lamp. Wired for energy saving T8 lamps. LP830 3000K 80+ CRI LP835 3500K 80+ CRI LP841 4100K 80+ CRI
C032 White white (high gloss) C099 Custom finish
DL DU ELH ELS ELS2 GLR GMF IND
*EL and EC are installed in last 4’ of luminaire sections. Separate feed required unless ELS or ELS2 is specified
Single circuit Dual circuit
Available with 28T5 only: LP830P 3000K 80+ CRI Premier LP835P 3500K 80+ CRI Premier LP841P 4100K 80+ CRI Premier
Damp location label Dust cover Emergency through wiring w/separate feed Emergency through wiring w/single feed, shared neutral Emergency through wiring w/single feed, separate neutrals Fusing (fast blow) Fusing (slow blow) Individual luminaire (factory installed end caps and hardware in the box) N100 nLight-Enabled (network ready with 10’ of Cat-5e) NYC New York City code
Reference Lamp Chart on website or consult factory for other options.
15
2246 5th Street Berkeley, CA 94710 510.845.2760 PeerlessLighting.com
© 2012 Acuity Brands Lighting, Inc. All rights reserved. “Peerless” and “nLight” are registered trademarks. Products in this brochure may be covered by one or more U.S. Patents and Patents Pending.