Urban Synergy @ Sheung Wan, Central, Hong Kong

Page 1


MASTERPLAN

URBAN SYNERGY I CENTRAL

MTR

Revitalizing Urban Typology InjecƟng Integrated Mixed Development EXISTING BUILDINGS NEW TYPOLOGY BUILDINGS REDEVELOPED BUILDINGS TRANSFORMED

Interlacing Transit Network Chain of Mobility

ESCALATOR BICYCLE ROUTE ROADS PERVIOUS PAVEMENT

SCALE 1:2000

Ecological Nexus Eco spines and Urban Boulevard

BOULEVARD PARKS FARMING ON RETAINING WALLS EXISTING GREENS WATER RETENTION BASINS WATER BODIES BIOSWALES

Reimagining Inclusivity BeƩer CooperaƟon between Public and Private

URBAN FARMING BUILDINGS REDEVELOPED

Low Carbon Model Integrated Hub of Clean energy & Renewables ECO BUILDING RETROFIT BUILDINGS SOLAR PV

URBAN ECOLOGIES

REFRENCES

URBAN APARATUS





Density/Program



Land Economic Value

Higher accesibility generated by the con nuous movement of people (MTR exits, Tram or bus stops, electric bicycles, carparks, & pedestrian walkway).

 Energy

Density 65000ppl Before 59000ppl



Livelihood (employment)



Energy Consump on

District Cooling System Amount of buildings serviced by DCS : 38% out of the total GFA of 1x1 km2.



Waste to Energy (WTE) Only 65% of the total municipal waste is combus ble (for incinera on process) out of 2.5kg/day/cap of waste by 65000ppl. Electricity generated : 120 GWh/yr



Combined Heat & Power Co-genera on plant for genera ng power in a combined process reducing transmission loast load compared to centralized plant.

 

Clean Energy Sources Hydropower turbines Solar PV panels

Water

: :

1200 MWh/yr 2500 MWh/yr

Retrofi ng old Buildings



PVPanel + Smart Ligh ng System + Green Appliances + GHP (CAVI Simula ons).

 

Clean Energy Source Transmission Lost

Raw water TreatmentPlant Rain water harvested on wet season : 2.150.000 lt on dry season : 250.000 lt Treated water used to supply for excess flushing use and Chilled water for DCS.

Nature



Water Consump on

Stormwater management Stormwater runoff collected by sqm of Bio-Reten on 8000 sqm : 2.5million liter (capacity) Biologically treated from polluted runoff water to become raw water (further treatment on the Hub to be non-potable water supply).



Environment



Water Treatment process

4.5 sqm/cap

2.7 sqm/cap

before 0.75 sqm/cap

before 0.8 sqm/cap

Walkable distance

From Conduit Rd to Connaught Rd (North-South) Regular tranporta on mode Time : 26 minutes Tariffs : 5 - 15 HK$ Con nuous walkable trail (with Regenera ve escalator) Time : 7 minutes Tariffs : 0 HK$

 

Vehicular use per capita GHG emission per capita


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.