Status
350
2370
1015
EQ
EQ
EQ
EQ
EQ
EQ
Design Development UNIT 4 - STYLE GUIDE
1015
General Notes 5mm SHADOWLINE
TV01
TV01 A.S. PL01
PL01
PL01
PL01
PL01
PL01
TV01
5
ALL DIMENSIONS TO BE CHECKED ON SITE, WRITTEN DIMENSIONS ONLY TO BE USED. DO NOT SCALE FROM DRAWING.
350
A.S. PL01
TV01
PT01
E-108
TV01
TV01
THE CONTRACTOR SHALL BE RESPONSIBLE TO LOCATE ALL SERVICES AND UTILITIES PRIOR TO COMMENCEMENT.
PL01
760
A.S.
PL01 PL01
PL01
PL01
PL01
PL01
PL01
PL01 TV01
PL03
PL01 PL03
KICKER
PL01
PL01
EQ
EQ
80
80
PL01
KICKER
OVEN
595 20
700 295 20 295
E-106
MICROWAVE
PL01
456
PL01
20
PL01
409
20 40
TILE SETOUT
80
TL04
20
E-104
ST01
20
ST01
TL04
2020
E-102
130 40
700
E-105
FRIDGE SPACE
20
30
F.S.
CONCEALED RANGEHOOD TO BE CENTRED ABOVE COOKTOP
2400
5
TV01
THE FOLLOWING NOTES TO BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL AND ENGINEERING DRAWINGS AND SCHEDULES RELATING TO THIS PROJECT. ALL DIMENSIONS ARE IN MILLIMETERS (MM) UNLESS OTHERWISE STATED.
795
30
F.S.
PT01
795
PL01
295
5
ALLOWANCE BEHIND CABINETS & PENETRATION INTO CEILING FOR OVEN + MICROWAVE VENTILATION
ALL DRAWINGS MAY NOT BE REPRODUCED OR DISTRIBUTED WITHOUT PRIOR PERMISSION FROM BAXTER + THRUM. SHOP DRAWINGS TO BE SUBMITTED TO BAXTER + THRUM FOR APPROVAL PRIOR TO CONSTRUCTION AND FABRICATION. ALL MEASUREMENTS ARE SUBJECT TO SITE MEASUREMENT. CONTRACTORS MUST VERIFY AND CHECK ALL SITE CONDITIONS, DIMENSIONS AND CEILING HEIGHTS BEFORE COMMENCING ANY WORK ON SITE OR PREPARING ANY SHOP DRAWINGS. ANY DISCREPENCIES ARE TO BE REFERRED IMMEDIATELY TO BAXTER + THRUM FOR CO-ORDINATION.
60 600
EQ
600
1
EQ
EQ
EQ
508
2120
508
EQ
EQ
1015
3000
600
415
OVEN
BROOM
EQUIPMENT AND APPLIANCES SHOWN DOTTED ARE INDICATIVE ONLY, REFER TO EQUIPMENT SCHEDULE FOR SPECIFICATIONS ON EQUIPMENT TO BE PROVIDED.
1015
ALL SHOP DRAWINGS TO BE SUBMITTED FOR INSPECTION BEFORE MANUFACTURE. CONFIRM ALL DIMENSIONS PRIOR TO CONSTRUCTION OF JOINERY UNITS. IN THE EVENT OF A DISCREPANCY BETWEEN SITE DIMENSIONS AND DRAWING DIMENSIONS JOINER MUST NOTIFY DESIGNER FOR INSTRUCTIONS.
KITCHEN - ELEVATION 01 1 : 20
ALL WORK SHALL COMPLY WITH RELEVANT AUTHORITY REQUIREMENTS AND AUSTRALIAN STANDARDS CODE FOR THAT TRADE.
1015
3000
ALL MATERIALS AND FITTINGS TO BE FIXED IN STRICT ACCORDANCE WITH THE MANUFACTURERS SPECIFICATION.
1015
EQ
NOTE:
EQ
A01.02
ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO MANUFACTURE OF JOINERY & INSTALLATION OF FF&E
ENSURE A FLUSH TRANSITION BETWEEN DIFFERENT FLOOR FINISHES. ALL WET AREAS TO BE CONSTRUCTED IN ACCORDANCE WITH BCA.
ISLAND BENCHTOP CANNOT EXCEED 3000mm TO ACHIEVE SINGLE PIECE OF STONE WITH NO JOINTS
5
CONTRACTOR TO CO-ORDINATE BETWEEN TRADES. CONTRACTOR TO CONFIRM SELECTED APPLIANCES IN THE FF&E SCHEDULE FIT NEATLY INTO RECESS PROVIDED, INCLUDING ALLOWANCE FOR SERVICE CONNECTION.
FINISHES: REFER TO INTERIOR FINISHES SCHEDULE.
ST02
FITTINGS: REFER TO FURNITURE, FIXTURES AND EQUIPMENT SCHEDULE.
970
E-102 A01.02
2
3
A01.02
NO CHANGE TO THE DESIGN OR SUBMISSION TO ANY PRODUCT WITHOUT BAXTER + THRUM APPROVAL IN WRITING.
600
E101.1
Rev. A
350
Issue Revision A
Drw. Appvd. Date MQ EH 31/5/19
1100
6 A01.01
A01.02
EQ
4
EQ
ST01
ST01
E-101
ABN: 77 995 334 095 studio@baxterandthrum.com baxterandthrum.com PO box 389 Narrabeen 2101
E-102
350
350
600
750
E-104
1620
1
Client
MICHAEL BARAKAT
Project 415
600
BROOM
OVEN
EQ
1015
EQ
1015
223 PLANTEAU RD, BILGOLA PLATEAU
2720
Drawing Title
UNIT 4 KITCHEN
2
KITCHEN - FLOOR PLAN 1 : 20
Drawn Date
Checked
MQ
31/5/19
Drawing No.
EH
Scale @ A1
Project No. Revision
A01.01
1 : 20
BT069
A