DETAIL DESIGN 30 JAN 2010
A1
1/500
AL MASHAAER AL MUGADDASSAH CIVIL WORK ARCHI & FINISHES MUZDALIFAH-2 STATION Platform Floor Plan General Layout Plan MMMP-DD-DWG-CWK-STAT-K&A-55-305
01
IS
AX K C A TR
IS
AX K C A R T
DETAIL DESIGN 30 JAN 2010
A1
1/125
AL MASHAAER AL MUGADDASSAH CIVIL WORK ARCHI & FINISHES MUZDALIFAH-2 STATION Platform Floor Plan Between Mz2-22 To Mz2-29 MMMP-DD-DWG-CWK-STAT-K&A-55-309
01
DETAIL DESIGN 30 JAN 2010
A1
1/500
AL MASHAAER AL MUGADDASSAH CIVIL WORK ARCHI & FINISHES MUZDALIFAH-2 STATION ELEVATIONS 1 & 2 General MMMP-DD-DWG-CWK-STAT-K&A-55-321
01
DETAIL DESIGN 30 JAN 2010
A1
1/125
AL MASHAAER AL MUGADDASSAH CIVIL WORK ARCHI & FINISHES MUZDALIFAH-2 STATION ELEVATION 2 Between Mz2-29 To Mz2-22 MMMP-DD-DWG-CWK-STAT-K&A-55-326
01
Mz2-22
Mz2-23
Mz2-24
Mz2-25
Mz2-26
Mz2-27
Mz2-28
DETAIL DESIGN 30 JAN 2010
A1
1/125
Mz2-29
AL MASHAAER AL MUGADDASSAH CIVIL WORK ARCHI & FINISHES MUZDALIFAH-2 STATION Section C-C Between Mz2-22 To Mz2-29 MMMP-DD-DWG-CWK-STAT-K&A-55-341
01
DETAIL DESIGN 30 JAN 2010
A1
1/50
AL MASHAAER AL MUGADDASSAH CIVIL WORK ARCHI & FINISHES MUZDALIFAH-2 STATION ELEVATOR 8 PLANS MMMP-DD-DWG-CWK-STAT-K&A-55-394
01
1
FIRE DOOR HYDRAULIC NICHE
2
01
3
4
01
A8231
5a
5
6
A8235
8
9
10
11
12
A8232
06 8402
FFL + 3069.151 FSL + 3069.151
7
01
C 4 HOUR FIRE RATED EXPANSION JOINT
6500
RL + 3069.177
RL + 3068.936
01
RL + 3069.184
870
14000 13000
FALL
TUNNEL ROAD
REFER TO MECHANICAL ENGINEERS DRAWINGS FOR DETAILS OF TUNNEL, FIRE DOORS
TUNNEL FIRE DOOR
RL + 3069.298
RL + 3069.057
01
RL + 3068.967
A8250
EGRESS TUNNEL BELOW SHOWN DASHED
FALL
CABLE ENCLOSURE
COF
11kv SWITCHROOM
A8235
01
COF
12100 12100
COF
01 8455
BATTERY COF
FIRE UP STAIR 3 INT FH
COF
01 8456
DIESEL GENERATOR ROOM
988 4730
FFL + 3069.206 FSL + 3069.206
CORRIDOR
COF
COF
2380
15160
FHR
A8251
ESCAPE PATHWAY 4730
UP
2035
INT FH
COF
01
UP
17770
DIESEL FUEL TANK BELOW 3500
2 HOUR FIRE RATED 1042 OPERABLE HATCH ABOVE SHOWN DASHED
COF
FALL RL + 3069.104
OPENING AS PER VENDOR REQUIREMENTS
COF
CORRIDOR
2230
FFL + 3069.356 FSL + 3069.356
FIRE STAIR 2
LV SWITCHGEAR ROOM
11kv/415v TRANSFORMER ROOM
A8251
15090
FFL + 3069.356 FSL + 3069.356
FIRE ESCAPE CORRIDOR COF
FIRE ESCAPE CORRIDOR
4725
01
4445
METAL LOUVERS WITH 2 HOUR FIRE RATED DAMPER 7075
5755
FH
7075
7040
RL + 3069.173
GRATED DRAIN CONNECT TO ECO0SOL PIT RL + 3069.122
3405
6170
RAMP
RL + 3069.212
UPS
9190
A8231
RL + 3069.254
3440
FIRE DOOR HYDRAULIC NICHE
01
RAMP
7075
FFL + 3069.402 FSL + 3069.402
RL + 3069.289
ELEC PIT
2230
4 HOUR FIRE RATED EXPANSION JOINT
RAMP
RL + 3069.316
ELEC PIT
UP
RL + 3069.339
FH
KERB
7075
RL + 3069.453
ELEC PIT RAMP
UP
06 8402
4700
6500
TUNNEL ROAD
26100
B
RL + 3068.846
EGRESS TUNNEL BELOW SHOWN DASHED
SETOUT POINT CH 9116.775
A8250
KERB
RL + 3069.063
COF
FHR
COF
FFL + 3069.111 FSL + 3069.111 COF
A RL + 3069.356
6000
6000
6000
4900
1100
6200
RL + 3069.207
5900
6000
6100
23909
4900
5100
8000
47930
RL + 3069.117
EGRESS TUNNEL PLANT BELOW SHOWN DASHED
71930
1. 2. 3. 4.
ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE SPECIFIED. ALL LEVELS ARE IN m UNLESS OTHERWISE SPECIFIED. ROAD LEVEL AT THE NPVB SETOUT POINT IS + 3069.226. PROVIDE 2HOUR FIRE SEPARATION IN TRENCHES BETWEEN COMPARTMENTS TYPICALLY 5. FOR FLOOR FINISH REFER TO FINISHES SCHEDULE. 6. FOR WALL FINISHES REFER TO THE "WALL SETOUT PLAN" AND "WALL TYPES" DRAWINGS AS WELL AS FINISHING SCHEDULES. 5. FOR CEILING FINISHES REFER TO "REFLECTED CEILING PLAN" AND FINISHING SCHEDULES.
01 8252
9183.475
9175.475
9170.375
9165.475
9159.375
9147.475
A8232
FFL + 3069.417 FINISHED FLOOR LEVEL FSL + 3069.417 FINISHED STRUCTURAL LEVEL FH
TUNNEL FIRE HYDRANT FHR
FIRE HOSE REEL
INT FH
01
INTERNAL FIRE HYDRATE
NPVB REDESIGN ISSUE (BUILDING RELOCATED)
MQ
RD
PA
08.03.19
H
FINAL DETAIL DESIGN ISSUE
NeGu
BaJe
MiKa
18.05.18
G
FINAL DETAIL DESIGN ISSUE
RP
BD
MK
20.08.13
F
DETAILED DESIGN ISSUE
BD
RP
MK
PRELIMINARY ISSUE
ED
BK
MK
27.06.13
D
REVISED TENDER ISSUE
0
0
0
16.09.11
ORIG
CHR
GROUND FLOOR PLAN SCALE - 1:100
NORTH PORTAL VENTILATION BUILDING
CLIENT
APV
DATE
Design Package
CONSULTANT
TITLE
Border Roads Organisation SMEC INTERNATIONAL PTY LTD
23.07.13
E
Revision
01
LEGEND
I
No
9140.175
9135.275
9129.275
9123.275
NOTES
9117.275
01 8253
9153.375
SEPTIC TANK BELOW SHOWN DASHED
Creates, Connects, Cares...
BRO
DATE
5th Floor, DLF Building No. 8 Tower C, DLF Cyber City, Phase-II Gurgaon - 122002 (Haryana) Tel: 91124-4376017 Fax: 91124-4376018 Email: smec@vsnl.com Website: www.smec.com.au
NAME
DATE
Client
BORDER ROADS ORGANISATION
Drawn
M.QANDIEL
08.03.2019
Project
ROHTANG TUNNEL, HIMACHAL PRADESH
Drafting Check
R.REYNOLDS
08.03.2019
Title
Designer
R.DUNLOP
08.03.2019
Design Check
T.CLINE
08.03.2019
NORTH PORTAL VENTILATION BUILDING GROUND FLOOR LAYOUT PLAN
Project Manager
R.DUNLOP
08.03.2019
Project Director
P.AGRAWAL
08.03.2019
Original Size Drawing Status
A1
DETAILED DESIGN
Drawing No.
5061071-ARC-A-8108
Rev
I
1
2
01
3
4
5a
01
A8231
6
7
01
A8235
8
9
10
WT-10 FR-120
270
200
2000 200
200
WT-10 FR-120
270
WT-10 FR-120
R (A) 18000
2300
2100
P6
2300
SETOUT POINT CH 9116.775
900
533 852 1457 4530
1329
01
P5 P6
8359
8933
MOBILE 01 8455
WT-10 FR-120
6000
4900
500
9135.275
9129.275
9123.275
9117.275
A
52 200
6000
1374
6000
P8
10
C) R ( SETOUT POINT RADIUS "A"
820 750 270 D02 3.3.1
2880
WT-10 FR-120
SETOUT POINT RADIUS "C"
FIRE STAIR 2
WT-16 -
2647
1415
2297
2832
D12 3.3.2 WT-15 -
1600
01 8456
WT-10 FR-120
D12 3.3.9
WT-16 -
WT-16 -
P2 WT-11 FR-120
ML-02 3.3.1
WT-16 -
1125
WC
WT-17 FR-120 D03 3.3.13
WT-12 FR-120
NOTE: PROVIDE INSULATION TO CAVITY
60 60
AIR LOCK D06 3.3.10
2830
1000
1215 D03 3.3.11
WT-10 FR-120
WT-18 -
3200
D06 3.3.12
FIRE D02 STAIR 3 3.3.8
130
ML-02 3.3.1
WT-06 -
1600
WT-16 -
WT-10 FR-120
WT-10 FR-120
HOUSING FOR DUCT
WT-12 FR-120
WT-10 FR-120
270 270 WT-15 -
1790
130
60
369 293 2341 2417 2113
KITCHEN
2833 2975
1078 3441
1231
WT-19 FR-120
WT-06 -
WT-12 FR-120
01 A8251
WT-16 -
WT-12 FR-120
7250
200 WT-16 -
WT-11 FR-120
0 13
D12 3.3.3
WT-16 -
WT-12 FR-120
NOTE: PROVIDE INSULATION TO CAVITY
WT-15 -
P7
WT-17 P4 FR-120
CONTROL EQUIPMENT ROOM
12100
A8251
WT-12 FR-120
270
60
WT-12 FR-120
200
01
0
1000
5820
D12 3.3.4
D02 3.3.14
4950
A8235
R (B)
2100
WT-10 FR-120
P9
200
A8231
RADIO
WT-12 FR-120
NOTE: PROVIDE INSULATION TO CAVITY
P3
4061
STORAGE & FIRE SERVICES ROOM
01
SETOUT POINT RADIUS "B"
900
5500
01
4515
1350
CORRIDOR
WT-16 -
100
2119 3505
2746
D02 3.3.5
500
2165
1797
1185
P1
80
200
WT-11 FR-120
1759
D2 3.3.6
WT-10 FR-120
200
WT-10 FR-120
936
P6
3694
3577
4151
WT-10 FR-120
2514
WT-10 FR-120
5791 5932
6542
P10
1129
3365
FAN HOUSE
2227
WT-10 FR-120
A8250
138 1524
5968
13000
STORAGE
7250
01
500
WT-10 FR-120
CONTROL ROOM
2100
2900
WATER TANK
D02 3.3.7
5820
2000
500
WT-10 FR-120
WT-10 FR-120
B
12
100
608
A8250
11
A8232
500
C
5
W-05 3.3.1
NOTES 1. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE SPECIFIED. 2. ALL LEVELS ARE IN m UNLESS OTHERWISE SPECIFIED. 3. PROVIDE 2HOUR FIRE SEPARATION IN TRENCHES BETWEEN COMPARTMENTS TYPICALLY 4. FOR FLOOR FINISH REFER TO THE "LAYOUT PLAN" AND FINISHES SCHEDULE. 5. FOR CEILING FINISHES REFER TO "REFLECTED CEILING PLAN" AND FINISHING SCHEDULES.
1100
LEGEND
PE
WALL PENETRATIONS NO
P1 P2 P3 P4 P5 P6 P7 P8 P9 P10
WINDOW TAG WXX - LOUVER TYPE A - BUILDING NUMBER B - FLOOR LEVEL C - WINDOW NO.FOR EACH ROOM WALL PENETRATION TO SUIT ELECTRICAL EQUIPMENT
SIZE
HEIGHT ABOVE FFL
200 x 200mm 300 x 300mm 250 x 250mm 250 x 250mm 3000 x 7000mm 3000 x 3000mm 1200 X 1200mm 1200 X 300 1200 X 300 250 x 250mm
4000mm 4000mm 4000mm 4000mm 500mm 500mm 500mm TBC TBC 4000mm
01 A8232
01
FIRST FLOOR - WALL SETOUT PLAN
CLIENT
NPVB REDESIGN ISSUE (BUILDING RELOCATED)
MQ
RD
PA
08.03.19
E
FINAL DETAIL DESIGN ISSUE
RP
RD
MK
20.08.13
D
DETAILED DESIGN ISSUE
RP
BD
MK
23.07.13
C
PRELIMINARY ISSUE
0
0
0
11.07.11
B
REVISED TENDER ISSUE
0
0
0
21.04.11
No
Revision
ORIG
CHR
APV
DATE
SCALE - 1:100
NORTH PORTAL VENTILATION BUILDING CONSULTANT
SMEC INTERNATIONAL PTY LTD Creates, Connects, Cares...
DATE
Design Package
TITLE
Border Roads Organisation
BRO
9183.475
LOUVER TAG ML-XX - LOUVER TYPE A - BUILDING NUMBER B - FLOOR LEVEL C - LOUVER NO.FOR EACH ROOM
F
8000
9175.475
DOOR TAG DXX - DOOR LEAF TYPE A - BUILDING NUMBER B - FLOOR LEVEL C - DOOR NO.FOR EACH ROOM
5100
9170.375
DXX A.B.C
W XX A.B.C
4900
9165.475
XX - FIRE RATING REFER TO SPECS.
6100
9159.375
FR-XX
6000
9153.375
XX - ACOUSTIC RATING REFER TO ACOUSTIC REPORT AS PER SPECS.
5900
9147.475
STC-XX -
ML-XX A.B.C
9140.175
WT-XX -
WALL TYPE TAG XX - WALL TYPE NUMBERING REFER TO WALL TYPE SCHEDULE AS PER SPECS.
6200
5th Floor, DLF Building No. 8 Tower C, DLF Cyber City, Phase-II Gurgaon - 122002 (Haryana) Tel: 91124-4376017 Fax: 91124-4376018 Email: smec@vsnl.com Website: www.smec.com.au
NAME
DATE
Client
BORDER ROADS ORGANISATION
Drawn
M.QANDIEL
08.03.2019
Project
ROHTANG TUNNEL, HIMACHAL PRADESH
Drafting Check
R.REYNOLDS
08.03.2019
Title
Designer
R.DUNLOP
08.03.2019
Design Check
T.CLINE
08.03.2019
NORTH PORTAL VENTILATION BUILDING FIRST FLOOR WALL SETOUT PLAN
Project Manager
R.DUNLOP
08.03.2019
Project Director
P.AGRAWAL
08.03.2019
Original Size Drawing Status
A1
DETAILED DESIGN
Drawing No.
Rev
5061071-ARC-A-8127
F
C
B
A
200mm GLASSWOOL THERMAL INSULATION FITTED ALONG THE CEILING AND AROUND INVERTED BEAMS WITH A MINIMUM R-VALUE OF 4.2 TO ACHIEVE A TOTAL R-VALUE OF 4.8
ROOF SHEETING STEEL TRUSS TO ENGINEERING DETAILS
U/S BEAM SFL. 3082.006 HOUSING FOR DUCT
LINE OF COLUMN BEYOND
CONCRETE BLADES
CUT THROUGH CONCRETE BLADE
LINE OF COLUMN BEYOND
6300
RCC TIE BEAM
STORAGE & FIRE SERVICES ROOM 3075.806
FIRST FLOOR LEVEL FSL. 3075.706
PLENUM
D15 3.1.17
RL. 3069.055
DUCT
EGRESS TUNNEL
PAVEMENT DRAIN PIPE
KERB
LINE OF TRENCHES BEYOND SHOWN DASHED
3066.221
11kv/415v TRANSFORMER ROOM
ELECTRIC TRENCH
FIRE CORRIDOR ESCAPE CORRIDOR
EGRESS TUNNEL BEYOND SHOWN DASHED
MIZZANINE LEVEL FSL. 3071.856
CONCRETE BARRIER
2500
TUNNEL ROAD
KERB
PROTECTIVE FC SHEET ON WATERPROOF MEMBRANE TO ENTIRE FACE OF PORTAL BUILDING
3850
5450 CLEAR
LINE OF CONCRETE BEAM
ROAD
50mm THICK PCC LINED WITH GRATING
6350
100mm HIGH CONCRETE HOB TO DOORWAY
3000
D02 3.3.5
GROUND FLOOR LEVEL FSL. 3069.356 EGRESS TUNNEL 3066.626
D17 3.1.20
TUNNEL CENTRELINE
01 A8163
01 NOTES
SECTION AT GRID 7 SCALE - 1:100
NORTH PORTAL VENTILATION BUILDING
1. 2. 3. 4.
ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE SPECIFIED. ALL LEVELS ARE IN m UNLESS OTHERWISE SPECIFIED. ROAD LEVEL AT THE NPVB SETOUT POINT IS + 3069.226. PROVIDE 2HOUR FIRE SEPARATION IN TRENCHES BETWEEN COMPARTMENTS TYPICALLY 5. FOR FLOOR FINISH REFER TO FINISHES SCHEDULE. 6. FOR WALL FINISHES REFER TO THE "WALL SETOUT PLAN" AND "WALL TYPES" DRAWINGS AS WELL AS FINISHING SCHEDULES. 5. FOR CEILING FINISHES REFER TO "REFLECTED CEILING PLAN" AND FINISHING SCHEDULES. 6. FOR TRUSS DETAILS AND EXACT SUPPORT LOCATIONS REFER TO STRUCTURAL DRAWING 5061071-ST-9296. 7. FOR LEVELS OUTSIDE THE BUILDING, EMBANKMENT AND GROUND TREATMENT, REFER TO GEOTECHNICAL DRAWINGS.
Design Package
CLIENT
CONSULTANT
TITLE
Border Roads Organisation SMEC INTERNATIONAL PTY LTD Creates, Connects, Cares... A No
NPVB REDESIGN ISSUE (BUILDING RELOCATED) Revision
MQ ORIG
RD
PA CHR
08.03.19 APV
DATE
BRO
DATE
5th Floor, DLF Building No. 8 Tower C, DLF Cyber City, Phase-II Gurgaon - 122002 (Haryana) Tel: 91124-4376017 Fax: 91124-4376018 Email: smec@vsnl.com Website: www.smec.com.au
NAME
DATE
Client
BORDER ROADS ORGANISATION
Drawn
M.QANDIEL
08.03.2019
Project
ROHTANG TUNNEL, HIMACHAL PRADESH
Drafting Check
R.REYNOLDS
08.03.2019
Title
Designer
R.DUNLOP
08.03.2019
NORTH PORTAL VENTILATION BUILDING SECTION AT GRID 7
Design Check
T.CLINE
08.03.2019
Project Manager
R.DUNLOP
08.03.2019
Project Director
P.AGRAWAL
08.03.2019
Original Size Drawing Status
A1
DETAILED DESIGN
Drawing No.
Rev
5061071-ARC-A-8232
A
12
11
10
9
8
7
6
5
5a
4
3
2
1
ROOF SHEETING CLADDING SHEETS TO MATCH ROOF SHEETING STEEL TRUSS TO ENGINEERING DETAILS CLADDING SHEETS TO MATCH ROOF SHEETING
200mm GLASSWOOL THERMAL INSULATION FITTED ALONG THE CEILING AND AROUND INVERTED BEAMS WITH A MINIMUM R-VALUE OF 4.2 TO ACHIEVE A TOTAL R-VALUE OF 4.8
03 -
U/S BEAM SFL. 3081.971
STEEL TRUSS TO ENGINEERING DETAILS
CONCRETE BLADES CONCRETE STRUCTURE TO ENGINEERING DETAIL
302
305
ROOF SHEETING
STEEL BRACING TO ENGINEERING DETAILS
DRAINAGE CELLS WITH GEOFABRIC ON PROTECTIVE FC SHEET ON WATERPROOF MEMBRANE SHOWN DASHED
2 HOUR FIRE RATED OPERABLE HATCH P4
6265
CAGE LADDER STEEL TRUSS TO ENGINEERING DETAILS
D02 3.3.14
P1
CUT THROUGH CONCRETE BLADE
HOUSING FOR DUCT
D02 3.3.5
STORAGE
PROVIDE 100mm WIDE JOINT WITH 50mm WIDE 4 HOUR FIRE RATED SEALANT THAT CAN EXPAND MIN 200% ALLOWING FOR 50mm JOINT MOVEMENT AND 15mm VERTICAL MOVEMENT OF TUNNEL
P5
100mm HIGH CONCRETE HOB TO DOORWAY
CLADDING SHEETS TO MATCH ROOF SHEETING
FIRST FLOOR LEVEL FSL. 3075.706
6350
200mm GLASSWOOL THERMAL INSULATION FITTED ALONG THE CEILING AND AROUND INVERTED BEAMS WITH A MINIMUM R-VALUE OF 4.2 TO ACHIEVE A TOTAL R-VALUE OF 4.8
04 -
PROVIDE SEALANT CAPABLE TO WITHSTAND JOINT MOVEMENT OF 50mm. SUPPORT SEALANT WITH EXTRUDED POLYSTYRENE WEDGE BELOW. RD2 3.1.16
D13 3.1.13
D15 3.1.17
D16 3.1.15
TUNNEL ROAD
D18 3.1.19
ROADWAY SHOWN HATCHED
1215 OPENING LENGTH
150
FIRE RATED ROOFING ACCESS HATCH
FIXING WALL BRACKET
205
THERMAL INSULATION
EGRESS TUNNEL
01
LONG SECTION SCALE - 1:100
NORTH PORTAL VENTILATION BUILDING
SAFETY HOOP
22095
-
900 OPENING WIDTH FIRE RATED ROOFING ACCESS HATCH 205
THERMAL INSULATION
2410
1220 TYP.
RUNGS
RUNGS 610
1. 2. 3. 4.
SAFETY HOOP
813
02 -
02
FIRE RATED ACCESS HATCH DETAIL
03
SCALE - 1:20
NORTH PORTAL VENTILATION BUILDING CLIENT
CAGED LADDER END DETAILS SCALE - 1:20
CONSULTANT
TITLE
MQ
RD
PA
08.03.19
B
REVISION AS MARKED
NeGu
JaPr
NeGU
04.09.18
A
DETAILED DRAWING
NeGu
BaJe
MiKa
16.05.18
Revision
ORIG
CHR
SMEC INTERNATIONAL PTY LTD
APV
DATE
Creates, Connects, Cares...
BRO
DATE
5th Floor, DLF Building No. 8 Tower C, DLF Cyber City, Phase-II Gurgaon - 122002 (Haryana) Tel: 91124-4376017 Fax: 91124-4376018 Email: smec@vsnl.com Website: www.smec.com.au
CAGED LADDER START DETAILS
04
NORTH PORTAL VENTILATION BUILDING
Border Roads Organisation NPVB REDESIGN ISSUE (BUILDING RELOCATED)
100
169
305 TYP.
1220
ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE SPECIFIED. ALL LEVELS ARE IN m UNLESS OTHERWISE SPECIFIED. ROAD LEVEL AT THE NPVB SETOUT POINT IS + 3069.226. PROVIDE 2HOUR FIRE SEPARATION IN TRENCHES BETWEEN COMPARTMENTS TYPICALLY 5. FOR FLOOR FINISH REFER TO FINISHES SCHEDULE. 6. FOR WALL FINISHES REFER TO THE "WALL SETOUT PLAN" AND "WALL TYPES" DRAWINGS AS WELL AS FINISHING SCHEDULES. 5. FOR CEILING FINISHES REFER TO "REFLECTED CEILING PLAN" AND FINISHING SCHEDULES.
1082
711
305 TYP.
600
SAFETY HOOP
NOTES
LINE OF CONCRETE ARCHWAY TO STRUCTURAL ENGINEERS DETAILS
PROVIDE SEALANT CAPABLE TO WITHSTAND JOINT MOVEMENT OF 50mm. SUPPORT SEALANT WITH EXTRUDED POLYSTYRENE WEDGE BELOW.
FALL
02
No
D18 3.1.27
GROUND FLOOR RL 3069.356 GROUND FLOOR RL 3069.206
DT01 8403
DT02 8403
LINE OF CONCRETE COLUMN BEYOND SHOWN DASHED
D15 3.1.1
3066.164
C
P6
FAN HOUSE
SCALE - 1:20
Design Package
NORTH PORTAL VENTILATION BUILDING NAME
DATE
Client
BORDER ROADS ORGANISATION
Drawn
M.QANDIEL
08.03.2019
Project
ROHTANG TUNNEL, HIMACHAL PRADESH
Drafting Check
R.REYNOLDS
08.03.2019
Title
Designer
R.DUNLOP
08.03.2019
NORTH PORTAL VENTILATION BUILDING SECTION ALONG CONTROL LINE
Design Check
T.CLINE
08.03.2019
Project Manager
R.DUNLOP
08.03.2019
Project Director
P.AGRAWAL
08.03.2019
Original Size Drawing Status
A1
DETAILED DESIGN
Drawing No.
Rev
5061071-ARC-A-8250
C
A
2050
A
03 -
120
03 -
120
WT-10 FR-120
2335
7320
04 -
ROAD
04
04
-
-
3140
13040 P1
04
EGRESS TUNNEL PLANT FFL + 3064.762 FSL +3064.762 3165
WT-10 FR-120
LINE CONCRETE BARRIER
WT-10 FR-120
D20 3.1.21 ML-01 3.1.2
135
7300
STEEL STAIR WITH GRATED TREADS/LANDING
WT-10 -
24 23 22 21 20 19 18 17 16 15 14 13 12 11
ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE SPECIFIED. ALL LEVELS ARE IN m UNLESS OTHERWISE SPECIFIED. ROAD LEVEL AT THE NPVB SETOUT POINT IS + 3069.226. PROVIDE 2HOUR FIRE SEPARATION IN TRENCHES BETWEEN COMPARTMENTS TYPICALLY 5. FOR FLOOR FINISH REFER TO FINISHES SCHEDULE. 6. FOR WALL FINISHES REFER TO THE "WALL SETOUT PLAN" AND "WALL TYPES" DRAWINGS AS WELL AS FINISHING SCHEDULES. 5. FOR CEILING FINISHES REFER TO "REFLECTED CEILING PLAN" AND FINISHING SCHEDULES.
220
9
10
940
220
940
2340
03
-
11
9
10
-
11
TUNNEL FIRE HYDRANT
1200 x 1200mm
EGRESS TUNNEL PLANT - GROUND FLOOR PLAN
02
SCALE - 1:50
SCALE - 1:50
NORTH PORTAL VENTILATION BUILDING
NORTH PORTAL VENTILATION BUILDING
HEIGHT ABOVE FFL TBA
9
HANDRAIL
TOP OF CONCRETE HOB FSL. 3064.725
7
660
EGRESS TUNNEL PLANT 1200
EMBANKMENT BEYOND SHOWN DASHED 6
5
4
CONCRETE HOB
FALL
FSL +3064.612
SLOPING SCREED 3
2
120
1 FSL +3064.725
EGRESS TUNNEL
970
BUILDING FOOTINGS
FSL +3064.762
20
EGRESS TUNNEL PLANT FLOOR FSL. 3064.762
EGRESS TUNNEL PLANT P1
05 FSL +3064.762 250
8
11
ROAD
EGRESS TUNNEL PLANT CEILING FSL. 3068.762
2130
CONCRETE WALL 9
ROAD
4000
10
KERB
23 24
1400
LANDING FSL. 3066.625
13
15
18
21
50mm THICK PCC LINED WITH GRATING
4000
11
12
14
16
17
19
20
22
10
CONCRETE BARRIER
1200
2660
KURB LEVEL FSL. 3069.285
1900
EGRESS TUNNEL PLANT - @ FSL. 3064.762
4000
SIZE
01
PROVIDE 150mm HOB AT STAIR LOCATION
24 RISERS @ 190mm 4560
FALL
940
03
WALL PENETRATIONS
P1
16 15 14 13 12 11
2340
FFL + 3069.417 FINISHED FLOOR LEVEL FSL + 3069.417 FINISHED STRUCTURAL LEVEL
NO
1500
1500
940
LEGEND FH
1 2 3 4 5 6 7 8 9 10
520
1. 2. 3. 4.
CONCRETE HOB
520
NOTES
1 2 3 4 5 6 7 8 9 10
LINE OF SLAB EDGE ABOVE SHOWN DASHED
WT-10 -
LINE OF HANDRAIL
2570
2570
LINE OF HANDRAIL
7353
LINE OF SLAB EDGE
1835
RL + 3069.133
STEEL STAIR WITH GRATED TREADS/LANDING
-
WT-10 FR-120
BOTTOM OF BUILDING FOOTINGS FSL. 3064.512
EGRESS TUNNEL PLANT - CROSS SECTION
03
04
EGRESS TUNNEL PLANT - LONGITUDINAL SECTION SCALE - 1:50
NORTH PORTAL VENTILATION BUILDING
SCALE - 1:50
NORTH PORTAL VENTILATION BUILDING CLIENT
CONSULTANT
TITLE
Border Roads Organisation SMEC INTERNATIONAL PTY LTD Creates, Connects, Cares... A No
NPVB REDESIGN ISSUE (BUILDING RELOCATED) Revision
MQ ORIG
RD
PA CHR
08.03.19 APV
DATE
BRO
DATE
5th Floor, DLF Building No. 8 Tower C, DLF Cyber City, Phase-II Gurgaon - 122002 (Haryana) Tel: 91124-4376017 Fax: 91124-4376018 Email: smec@vsnl.com Website: www.smec.com.au
NAME
DATE
Design Package
Client
BORDER ROADS ORGANISATION
Drawn
M.QANDIEL
08.03.2019
Project
ROHTANG TUNNEL, HIMACHAL PRADESH
Drafting Check
R.REYNOLDS
08.03.2019
Title
Designer
R.DUNLOP
08.03.2019
NORTH PORTAL VENTILATION BUILDING EGRESS TUNNEL PLANT DETAILS
Design Check
T.CLINE
08.03.2019
Project Manager
R.DUNLOP
08.03.2019
Project Director
P.AGRAWAL
08.03.2019
Original Size Drawing Status
A1
DETAILED DESIGN
Drawing No.
Rev
5061071-ARC-A-8252
A
ROOF SHEETING TOP HAT AS PER ENGINEERING
A
PFC RAFTER AS PER ENGINEERING METAL SHEET CLADDING
34720
13710
21010
02
TOP HAT AS PER ENGINEERING
BOTTOM OF UPPER ROOF RAFTER SFL. 3071.063
GUARD RAIL
-
20°
RL + 3069.117
GUARD RAIL
SHS WALL AS PER ENGINEERING
-
04
RAMP LEVEL @ PARKING FSL. 3069.117
UPPER ROOF
-
03
LOWER ROOF
TOP HAT AS PER ENGINEERING
MIN. 2400
50mm THICK PCC LINED WITH GRATING
03
METAL SHEET CLADDING
SHS WALL AS PER ENGINEERING
RETAINING WALL AS PER ENGINEERING
-
04 02
-
-
4000
LINED OF RAMP BELOW SHOWN DASHED
1
2
3
4
5a
5
6
7
8
EGRESS TUNNEL RAMP - LAYOUT
01
EGRESS TUNNEL RAMP CROSS SECTION
02
SCALE - 1:100
SCALE - 1:50
NORTH PORTAL VENTILATION BUILDING
NORTH PORTAL VENTILATION BUILDING ROOF SHEETING TOP HAT AS PER ENGINEERING
ROOF SHEETING
SHS AS PER ENGINEERING
2400
FSL +3069.117
3093
3255
RAMP LEVEL @ PARKING FSL. 3069.117
1000
METAL SHEET CLADDING
05 -
D17 3.1.20
EGRESS TUNNEL RAMP FLOOR FSL. 3066.024
FSL +3066.024 DOOR LEAF IN OPEN POSITION SHOWN DASHED
RAMP 1:14 SLOPE
DOOR AND FRAME
EGRESS TUNNEL RAMP SECTION 3
03
2100
SCALE - 1:100
NORTH PORTAL VENTILATION BUILDING
TOP HAT AS PER ENGINEERING
ROOF SHEETING
PFC AS PER ENGINEERING
SHS AS PER ENGINEERING BOTTOM OF UPPER ROOF RAFTER SFL. 3071.063
EGRESS TUNNEL RAMP FLOOR FSL. 3066.024
1017
FSL +3066.024
111
1946
1555
GRATED DRAIN WITH DRAIN PIPE OUTLET AT THE EMBANKMENT
NOTES 1. 2. 3. 4.
ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE SPECIFIED. ALL LEVELS ARE IN m UNLESS OTHERWISE SPECIFIED. ROAD LEVEL AT THE NPVB SETOUT POINT IS + 3069.226. PROVIDE 2HOUR FIRE SEPARATION IN TRENCHES BETWEEN COMPARTMENTS TYPICALLY 5. FOR FLOOR FINISH REFER TO FINISHES SCHEDULE. 6. FOR WALL FINISHES REFER TO THE "WALL SETOUT PLAN" AND "WALL TYPES" DRAWINGS AS WELL AS FINISHING SCHEDULES. 5. FOR CEILING FINISHES REFER TO "REFLECTED CEILING PLAN" AND FINISHING SCHEDULES. 6. FOR EXACT EGRESS TUNNEL ROOFING DETAILS REFER TO STRUCTURAL DRAWINGS.
EGRESS TUNNEL RAMP SECTION 4
04
RAMP 1:14 SLOPE
2790
D17 3.1.20
1940
3093
4189
RAMP LEVEL @ PARKING FSL. 3069.117
1000
2400
BOTTOM OF LOWER ROOF RAFTER SFL. 3070.213
1640
05
SCALE - 1:100
NORTH PORTAL VENTILATION BUILDING
PROVIDE LOCALISED SCREED OVER EGRESS TUNNEL TO CREATE RAMP AND LANDING
EGRESS TUNNEL DOOR SCALE - 1:20
NORTH PORTAL VENTILATION BUILDING
LEGEND FFL + 3069.417 FINISHED FLOOR LEVEL FSL + 3069.417 FINISHED STRUCTURAL LEVEL
Design Package
CLIENT
CONSULTANT
TITLE
Border Roads Organisation SMEC INTERNATIONAL PTY LTD Creates, Connects, Cares... A No
NPVB REDESIGN ISSUE (BUILDING RELOCATED) Revision
MQ ORIG
RD
PA CHR
08.03.19 APV
DATE
BRO
DATE
5th Floor, DLF Building No. 8 Tower C, DLF Cyber City, Phase-II Gurgaon - 122002 (Haryana) Tel: 91124-4376017 Fax: 91124-4376018 Email: smec@vsnl.com Website: www.smec.com.au
NAME
DATE
Client
BORDER ROADS ORGANISATION
Drawn
M.QANDIEL
08.03.2019
Project
ROHTANG TUNNEL, HIMACHAL PRADESH
Drafting Check
R.REYNOLDS
08.03.2019
Title
Designer
R.DUNLOP
08.03.2019
NORTH PORTAL VENTILATION BUILDING EGRESS TUNNEL RAMP DETAILS
Design Check
T.CLINE
08.03.2019
Project Manager
R.DUNLOP
08.03.2019
Project Director
P.AGRAWAL
08.03.2019
Original Size Drawing Status
A1
DETAILED DESIGN
Drawing No.
Rev
5061071-ARC-A-8253
A
3530
3025
2380
20 19 18 17 16 15 COF
COF
275
9
-
COF
1880 26
27 25
02
FIRE STAIR 3 - MEZZANINE FLOOR PLAN
05
SCALE - 1:50
NORTH PORTAL VENTILATION BUILDING
1050
SCALE - 1:50
NORTH PORTAL VENTILATION BUILDING
11
2475
50
8
7
31
53 51
LANDING FSL. 3078.686
52
LANDING FSL. 3076.526 39
38
32
33
34
35
TOP OF LANDING FIRST FLOOR FFL. 3075.806
37 36
FIRST FLOOR FSL. 3075.706 05 8455
23
22
12
13
21
20
19
18
LANDING FSL. 3073.831
17
16
14
15
MEZZANINE FSL. 3071.856 LANDING FSL. 3071.142
6
5
4
3
2
1
GROUND FLOOR FSL. 3069.356
COF 275 25 24 23 22
280 1050
9
CABLE ENCLOSURE
1880
2380
24
29
30
FIRE STAIR 3 - WATER TANK LEVEL 10
9
28
B
1000
B
49
54
04
1000
825
44
46
48
40
47 48 49 50 51 52
-
42
41
43
45
47
55
3600 20 RISERS @ 180mm
LINE OF HANDRAIL
1050
04
825
56 55 54 53 COF
56
3950 22 RISERS @ 180mm
275
LINE OF HANDRAIL
1880
NORTH PORTAL VENTILATION BUILDING
2500 14 RISERS @ 179mm
UP
1050 280 1050
500L WATER TANK
INT FH
LANDING FSL. 3079.406
SCALE - 1:50
3530
3300
275 10 9 8 7 6
FIRE STAIR 3 - LANDING @ FSL. 3078.686
720
NORTH PORTAL VENTILATION BUILDING
11 12 13 14
9
04
SCALE - 1:50
1050
FIRE STAIR 3 - GROUND FLOOR PLAN
1330
FIRE STAIR 3
500L WATER TANK
2160
1330
B
01
2380
-
COF
280
B
B
04
720
9
41 42 43 44 45 46 47 48 49 50 51 52
1975
9
275
1975
-
56 55 54 53
714
1100
04
INT FH
COF 275
1786
LINE OF HANDRAIL
1050
285
LINE OF HANDRAIL
1050
2380
5 4 3 2 1
2380
COF
825
280
UP
1150
CABLE ENCLOSURE
3805
40 39 38 37 COF
275
26 27 28 29 30 31 32 33 34 35 36 LINE OF INT HANDRAIL FH
COF
1330
FSL +3068.006
04 -
2750
FIRE STAIR 3 - SECTION
06
SCALE - 1:50
NORTH PORTAL VENTILATION BUILDING
B
03
FIRE STAIR 3 - FIRST FLOOR PLAN SCALE - 1:50
NORTH PORTAL VENTILATION BUILDING
NOTES 1. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE SPECIFIED. 2. ALL LEVELS ARE IN m UNLESS OTHERWISE SPECIFIED. 3. ROAD LEVEL AT THE NPVB SETOUT POINT IS + 3069.226.
Design Package
H
NPVB REDESIGN ISSUE (BUILDING RELOCATED)
MQ
RD
PA
08.03.19
G
DETAILED DRAWING
NeGu
JaPr
MiKa
04.09.18
F
FINAL DETAIL DESIGN ISSUE
NeGu
BaJe
MiKa
18.05.18
E
DETAILED DESIGN ISSUE
RD
RP
MK
DETAILED DESIGN ISSUE
RP
RD
MK
23.07.13
C
FINAL TENDER ISSUE
0
0
0
11.07.11
Revision
ORIG
CHR
CONSULTANT
APV
DATE
TITLE
Border Roads Organisation SMEC INTERNATIONAL PTY LTD
20.08.13
D
No
CLIENT
Creates, Connects, Cares...
BRO
DATE
5th Floor, DLF Building No. 8 Tower C, DLF Cyber City, Phase-II Gurgaon - 122002 (Haryana) Tel: 91124-4376017 Fax: 91124-4376018 Email: smec@vsnl.com Website: www.smec.com.au
NAME
DATE
Client
BORDER ROADS ORGANISATION
Drawn
M.QANDIEL
08.03.2019
Project
ROHTANG TUNNEL, HIMACHAL PRADESH
Drafting Check
R.REYNOLDS
08.03.2019
Title
Designer
R.DUNLOP
08.03.2019
NORTH PORTAL VENTILATION BUILDING FIRE STAIR FS3 DETAILS
Design Check
T.CLINE
08.03.2019
Project Manager
R.DUNLOP
08.03.2019
Project Director
P.AGRAWAL
08.03.2019
Original Size Drawing Status
A1
DETAILED DESIGN
Drawing No.
Rev
5061071-ARC-A-8456
H