TDS_QUAKERCOAT 024_EN

Page 1

TECHNICAL DATA SHEET QUAKERCOAT® 024!! CLEAR 100 % UV CURING, PERMANENT PROTECTIVE COATING

QUAKERCOAT® 024 is a medium gloss 100 % UV curing, permanent protective coating. QUAKERCOAT® 024 is VOC compliant with the European directive 2004/42/CE limiting volatile solvent contents in paints and varnishes.

Benefits · · · · · ·

Applications QUAKERCOAT® 024 is intended for use as a corrosion protective varnish on metal tube and pipe surfaces.

VOC Compliant Instant curing with very low energy Good adhesion even on difficult substrates, improved compatibility with contaminants Medium gloss film Excellent corrosion protection Low viscosity for easier sprayability and lower energy consumption

Typical Dry Film Properties

Typical Physical Properties

PROPERTY PROPERTY

TYPICAL VALUE

UNIT

Appearance

Milky white

[-]

1144

[kg/m³, 25 °C]

Specific Gravity @25°C Flash point

135

[°C], closed cup

Viscosity

40

seconds, FordCup 4, 25 °C

VOC (calculated)

<0.1

[g/l]

Solids %

100

[% weight]

Coverage at 35 µm

28,6

[m²/l]

TYPICAL VALUE

UNIT

250

mJ/cm² / UVA or via UV stripes

>200

hours, DIN 50 021 SS on Qpanels, below 5% rust.

Medium

[-]

Hardness Persoz ISO 1522

135

seconds

Color

clear

[-]

Recommended dry film thickness

35-50

µm

Recommended energy dose

Corrosion resistanceSalt spray

Gloss

These characteristics are typical of current production and can't be used as a specification.

!

©2020 Quaker Houghton. All rights reserved.

quakerhoughton.com | info@quakerhoughton.com

V001.20.05.EN.EU


Viscosity for QUAKERCOAT® 024

Recommendation for use The following directions and recommendations are intended to serve as a guide and may require modifications to meet local needs. » THINNING: use as received. » MATERIALS: QUAKERCOAT® 024 is designed for coating of steel and galvanised steel. » SURFACE PREPARATION: the intended substrate must be clean and dry to accept the protective coating properly. Loose debris, dust, or other contamination may degrade product effectiveness and performance. » APPLICATION: for spray applications. Maintain equipment always clean. Use with adequate ventilation. Avoid breathing overspray or vapours. Consult Material Safety Data Sheet for handling and safety information. It is recommended to spray the coating between 30 and 40 ºC. » CURING: minimum energy required is 150 mJ/cm², but thicker films or darker substrates may require higher energy dosages. » CLEANING: it is recommended to use QUAKERCOAT UV Thinner or QUAKERCOAT UV diluent to preclean or rinse the system. Those products offer excellent compatibility with QUAKERCOAT® 024 and will not impart the final corrosion protection.

Health, Safety and Handling Please consult the Safety Data Sheet (SDS) for information on storage, safe handling and disposal. The conditions or methods of handling, storage, use and disposal of the product are beyond our reasonable control - we assume no liability for any ineffectiveness of the product or any injury or damage, arising out of or in connection with these conditions.

All!reasonable!care!has!been!taken!to!ensure!this!publication!is!accurate!upon!issue.!Such!information!may!be!affected!by!changes! subsequent!to!issue.!!This!Technical!Data!Sheet!is!to!be!used!solely!for!this!product.!Prior!to!any!use,!consult!the!Safety!Data!Sheet!(SDS)! for!information!on!hazard!risks!and!product!use!parameters.!All!liability!and!all!warranties!express!or!implied!are!hereby!excluded!as!to! product!performance!results,!the!accuracy!of!these!data!including!any!warranty!of!merchantability!or!fitness!for!any!purpose.!!!! 042968UNPK03

©2020 Quaker Houghton. All rights reserved. !

quakerhoughton.com | info@quakerhoughton.com

V001.20.05.EN.EU