RAIS Gas 2019 GB

Page 1

MARCH 2019

VISIO

EXCLUSIVE FIREPLACE INSERTS FOR GAS SLOW DOWN, LEAN BACK & ENJOY


DREAMS DO COME TRUE

RAIS Visio Gas is an exclusive collection of fireplace inserts for gas offering a variety of different design options to make your fireplace dream come true.

Choose a corner fireplace to enjoy the flames and the warmth from every angle, a see-through tunnel model to create an open space feel, or what about an insert with glass on three sides?

No matter what model you choose, RAIS Visio fireplace inserts offer a sleek, contemporary design and create welcoming living spaces with the dancing flames as a natural focal point.

It is time to slow down, lean back & enjoy.

Let us inspire you!

RAIS VISIO 160/45/32 RC

2


RAIS VISIO 90/55/39 LC

3


THE CHOICE IS YOURS! We know that there is a RAIS Visio Gas insert that matches your dreams, your home and interior, but with all the must-have design options and unique features to choose between, we are not making it easy for you to decide.

RAIS VISIO 43/49/65 RD

View over Glass measurements for different inserts RAIS VISIO 70

RAIS VISIO 70 RD

RAIS VISIO 70 T

Glasmål 70 cm Glasmål 43/65 cm

Glasmål 65 cm

The extensive collection includes a huge choice of shapes, sizes, capacities and accessories to suit any type of décor offering you the ultimate freedom to design your personal fireplace experience.

RAIS VISIO 90

Glasmål 90 cm

RAIS VISIO 160 RAIS VISIO 90 T Glasmål 90 cm

Glasmål 160 cm

4

RAIS VISIO 90 T Glasmål 40/90 cm


FRONT MODELS Front models are available in various sizes and shapes. From small and discreet to large and wide, there is a front model to fit any room and interior. RAIS VISIO 70 F

RAIS VISIO 90 F

RAIS VISIO 160 F

RAIS VISIO 70 LC

RAIS VISIO 90 LC

RAIS VISIO 160 LC

RAIS VISIO 70 RC

RAIS VISIO 90 RC

RAIS VISIO160 RC

RAIS VISIO 70 3S

RAIS VISIO 90 3S

RAIS VISIO 160 3S

RAIS VISIO 70 RD

RAIS VISIO 90 RD

RAIS VISIO 70 T

RAIS VISIO 90 T

70/43 F

90/55 F

160/45 F

CORNER MODELS Enjoy the fireplace ambience from multiple angles with a corner model. Available in two versions – for left and right corners. 70/43/39 LC

70/43/39 RC

90/55/39 LC

90/55/39 RC

160/45/32 LC

160/45/32 RC

THREE-SIDED MODELS Three-sided fireplace inserts offer impressive views of the fire and give you the ultimate freedom to design your own fireplace experience.

70/43/39 3S

90/55/39 3S

160/45/32 3S

ROOM DIVIDERS Use a Visio gas fire as an architectural element to divide up an open space and highlight your home’s modern design aesthetic.

43/49/65 RD

40/55/90 RD

TUNNEL MODELS Tunnel models offer a see-through feature and allow you to enjoy the cozy fireplace vibe in two rooms.

43/49/65 T

40/55/90 T

5


Scan QR code to see RAIS Visio in action.

6


CREATE AN AUTHENTIC FIREPLACE EXPERIENCE - WITH JUST A TOUCH OF A BUTTON Convenient and practical, RAIS Visio Gas inserts allow you to enjoy the flickering flames, the warmth and an authentic fireplace atmosphere with just a touch of a button. The inserts generate spectacular and authentic flame images that catch the eye, and with integrated and adjustable LED lighting you

can enjoy the beautiful illusion of glowing coals and smouldering embers. To create the ultimate fireplace experience, RAIS Visio gas inserts are equipped with glass stones that beautifully reflect the fire, natural-looking ceramic coals and logs indistinguishable from real wood logs.

7


FRONT MODEL

RAIS VISIO 160 F Front models are available in various sizes and shapes. From small and discreet to large and wide, there is a front model to fit any room and interior.

Scan QR code to see RAIS Visio in action. 8


CORNER MODEL

RAIS VISIO 90 RC Enjoy the fireplace ambience from multiple angles with a corner model. Available in two versions – for left and right corners.

Scan QR code to see RAIS Visio in action. 9


THREE-SIDED MODEL

RAIS VISIO 90 3S

TUNNEL MODEL

Three-sided fireplace inserts offer impressive views of the fire and give you the ultimate freedom to design your own fireplace experience.

Scan QR code to see RAIS Visio in action.

RAIS VISIO 90 T Tunnel models offer a see-through feature and allow you to enjoy the cozy fireplace vibe in two rooms.

10


ROOM DIVIDER Scan QR code to see RAIS Visio in action.

RAIS VISIO 90 RD Use a Visio gas fire as an architectural element to divide up an open space and highlight your home’s modern design aesthetic.

11


EASY TO USE

12


REMOTE CONTROL

APP WITH WIFI TURN THE FIRE ON WITH YOUR SMART DEVICE Download our Myfire app for IOS or Android and control your RAIS Visio Gas fireplace with any mobile device. All you need to get started is our Wi-Fi Box and internet access. Turn the fire on or off, adjust the temperature and the flames from your smartphone or iPad. It is easy, convenient and flexible. 13


THE GAS FIREPLACE INSERTS ARE EQUIPPED WITH: LED light

Different types of ceramic logs

Filament

Ceramic coal, grey and black

Glass matt rounded Glass clear broken

IT HAS NEVER BEEN EASIER… Creating the perfect fireplace ambience has never been easier with stepless regulation of heat output (kW) and flame height.

Scan QR code to see RAIS Visio in action.

14


For frontmodels: Non-reflective glass to upgrade the flame image

Frames in black and stainless steel

Black mirrorglass as backing Scan QR code to see RAIS Visio in action.

Convection grates in black or white

DESIGNED TO MAKE A DIFFERENCE Enhance your fireplace experience with our comprehensive range of exclusive accessories. Choose between frames in black and stainless steel, convection grates in black or white or add non-reflective glass or black mirror glass to upgrade the flame image. No matter what you choose, all our accessories are designed to make a visible difference.

Access door in black or white

wi-fi Box

15


SPECIFIKATIONER

RAIS VISIO 70 F

RAIS VISIO 90 F

TECHNICAL DATA:

TECHNICAL DATA: MEASUREMENT (W-D-H)

Recommended free convection openings min. 200 cm²

Min. 1000

Min

Ø149

Min. 50

A

Min. 50

144,5

Min. 1000

Min. 50

Ø131

54

145

C

346,5 54

69

484 **

145

3

A

494 **

54 484 **

898

538 688

405

538

69

3

Min. 405

Min. 50 Min. 1000

144,5

782,5

Mi n.

Min

48 9

538

,5 69 .7

144,5 A

494 ** Ø149 Ø101

B RAIS Visio Gas 70-43-39 LC-654201 54 A-A

344

425

54

A

RAIS VISIO 160/45 F 1619

468

54

16

C

A 826

13

54 484 **

405 48

76

9 ,5

9

538 782,5

RAIS Visio Gas 70-43-39 LC-6541

727,5 **

144,5

405

393,5 769,5

RAIS VISIO 70/43/39 LC

B

634

405

03

737,5 **

1598

16

489

425 145

654

704

684

144,5

A

727,5 ** 54

C

54 484 **

737,5 **

54

A-A

RAIS Visio Gas 70

Min. 50

C 826

Inspection hatch

Ø131

,5 69 .7

B

RAIS Visio Gas 160-45 F-654201

144,5

Min

B

A

1603

48 9

54

A-A

Min. 50

Ø199

Mi n.

145

Min. 50

801,5

Inspection hatch

Ø101

Min. 50

3 60 .1

Inspection hatch

1690

494 **

Ø149

144,5

Min

0 mm 0 mm 1000 mm 150 mm 1000 mm

405

Inspection hatch

To side wall To Min.back 50 wall To the ceiling RAIS Visio Gas 160-45 F-654201 To the floor A To furniture

Min. 405

Min. 50

425

1598

323,5

DISTANCE TO FLAMMABLE MATERIAL

54

468

105 kg

634

3 60 .1

RAIS Visi

405

1619

Min

Min. 50

A

0 mm 0 mm 1000 mm 150 mm 1000 mm

145

654

side wall back wall the ceiling the floor furniture

Weight

Min. 425

DISTANCE TO FLAMMABLE MATERIAL

Min. 1000

Min. 1000 Min. 425

170 54 kg

convection openings min. 200 cm²

684

Nominal heat input: Natural gas - G20 I2H/I2E 1,9 - 8,8 kW Nominal effect input: Propane gas - G30/G31 I3B/P(30) 1,8 - 8 kW Efficiency Recommended free 91 %

Min. 50

A-A

144,5

Recommended free convection openings min. 200 cm²

External dimensions 826-538-684 mm Finished face opening 769,5-489-405 mm Outer frame dimensions 769,5-489-405 mm Flue outlet (diameter) Ø100 / Ø150 mm Outer diameter gas connection Ø8 mm

KEY FIGURES

Min. 1000

Ø131

To To To To To

RAIS Visio Gas 70-43F-6541

Recommended free

Nominal heat input: Natural gas - G20 I2H/I2E 3 - 17,2 kW convection openings 200 cm² I3B/P(30) Nominal effect input: Propane gas -min. G30/G31 2,7 - 16,5 kW Ø199 Efficiency 92 % Weight

393,5

MEASUREMENT (W-D-H) Recommended free convection openings min. 200 cm²

External dimensions 1690-468-704 mm Finished face opening 1603-425 mm Outer frame dimensions 1603-425 mm Flue outlet (diameter) Ø130 / Ø200 mm Outer diameter gas connection Ø10 mm

A

903

TECHNICAL DATA:

780

MEASUREMENT (W-D-H)

KEY FIGURES

RAIS Visio Gas 90-55 F-6541

RAIS VISIO 70 LC

346,5

693

TECHNICAL DATA:

144,5

54

393,5

538

RAIS VISIO 160 F

3

RAIS VISIO 90/55 F898

RAIS Visio Gas 70-43F-6541

144,5

RAIS VISIO 70/43 F

90

494 ** 538

145

A

525

754

804

405

903

C

693 693 780

54

B C

405

634

54

393,5

538 144,5

A-A

144,5 A

B

393,5

538 684

B

Ø199

B

54

Min. 50

RAIS Visio Gas 90-55 F-654201

494 **

898

A-A

688 A

681

Min. 525

494 ** 538

54 RAIS Visio Gas 70-43 F-654201

484 ** Ø149 494 ** Ø101 538

. Min

484 **

898

145

A

Min. 50

3

90 54

Inspection hatch

525

Min. 50

C C

C

144,5

RAIS Visio Gas

Min. 50

B

405

634

684

B

3 69 in.

693

03 .9

C

525

A-A 54

Inspection hatch

Min

B

Ø101

A

681

Min. 50

B

Inspection hatch

145

144,5

M

93 .6

Min. 405

Inspection hatch

145 kg 494 ** DISTANCE TO FLAMMABLE MATERIAL Ø199 To side 0 mm Min. 50 Min. wall 50 Ø131 To back wall A-A 0 mm 144,5 54 To the ceiling 1000 mm A the floor 150 mm RAIS Visio Gas 70-43ToF-654201 To furniture 1000 mm

754

0 mm 0 mm 1000 mm 150 mm 1000 mm

convection openings min. 200 cm²

Weight

Min. 1000

110 kg

804

Recommended free convection openings

min. 200 cm² DISTANCE TO FLAMMABLE MATERIAL To side wall To back wall To the ceiling To the floor To furniture

Nominal heat input: Natural gas - G20 I2H/I2E 2,5 - 11 kW Nominal effect input: Propane gas - G30/G31 I3B/P(30) 2,4 - 10,8 kW Recommended free Efficiency 91,5 % Min. 50

Nominal heat input: Natural gas - G20 I2H/I2E 1,9 - 8,8 kW Nominal effect input: Propane gas - G30/G31 I3B/P(30) 1,8 - 8 kW Efficiency 91 % Weight

KEY FIGURES

Min. 405

KEY FIGURES

Recommended free convection openings min. 200 cm²

External dimensions 990-538-804 mm Finished face opening 903-525 mm Outer frame dimensions 903-525 mm Flue outlet (diameter) Ø100 / Ø150 mm Outer diameter gas connection Ø8 mm

Min. 1000

External dimensions 780-538-684 mm Finished face opening 693-405 mm Outer frame dimensions 693-405 mm Flue outlet (diameter) Ø100 / Ø150 mm Outer diameter gas connection Ø8 mm

Min. 525

MEASUREMENT (W-D-H)

344

C


SPECIFIKATIONER

RAIS VISIO 90 LC

RAIS VISIO 160 LC

TECHNICAL DATA:

TECHNICAL DATA: MEASUREMENT (W-D-H)

Recommended free convection openings min. 200 cm²

Min. 525

KEY FIGURES

525

Min. 1000

468

145

1647,5 ** 1637,5 **

Inspection hatch

Ø199

937,5 **

424 **

Ø131

1678,5

144,5

54

A-A

B

54 A-A

B

B C

425

654

425

704

525

525

754

C

145

145

13 C A

9 97

484 **

48

,5

1736

9

414 **

41

468

RAIS VISIO 160/45/32 LC

538

1647,5 **

799

RAIS Visio Gas 90-55-39 LC-6541

144,5

1678,5

Ø101

54 A-A

A

634

405

405

B

Min. 50

0 mm 0 mm 1000 mm 150 mm 1000 mm

Mi n.

992,5

C

RAIS VISIO 70/43/39 RC

782,5 737,5 ** 727,5 **

484 ** 538

54

B

54

525

393,5

979,5

525

13

145

C

145

76

9,

A

5

48

54

9

1036

RAIS VISIO 90/55/39 RC

RAIS Visio Gas 70-43-39 RC-6541

484 ** 538

97

9 ,5

48

9

17

344 992,5

,5

A-A

405

405 489

634

405

684 393,5

54 826

RAIS Visio Gas 90-55-39 RC-654201

Ø131

B

C

A

494 **

Ø199 144,5

449

54

769,5

54 484 **

Inspection hatch

A

54

13

89 .4 Min

937,5 **

RAIS Visio Gas 70-43-39 RC-654201 B

B

97 9, 5

947,5 **

538

A-A

144,5

A

RAIS Visio

489

144,5

782,5 494 ** 737,5 ** Ø149 727,5 ** 344Ø101

Inspection hatch

538

754

9 48 n. Mi

89 .4 Min

Min. 50

54

Inspection hatch

B

97 9, 5

754

1036

804

76 9, 5

54

144,5

Mi n.

A-A

C

A

484 **

826

9

Min. 50

145

Min. 50

41

RAIS Visio Gas 160-45-32 LC-654

C

A

,5

145

144,5

Ø149 Inspection hatch

144,5

78

140 kg

Min. 50

9 48 n. Mi

16

Ø131

Mi n.

Min. 525

76 9, 5

DISTANCE TO FLAMMABLE MATERIAL

To side wall To back wall B To the ceiling RAIS Visio Gas 70-43-39 RC-654201 To the floor C To furniture

494 ** Mi n.

684

Min. 405

0 mm 0 mm 1000 mm 150 mm 1000 mm

494 ** Ø199

804

Min. 50

side wall back wall the ceiling the floor furniture

A

RAIS Visio Gas 90-55-39 LC-6541 Weight

Min. 1000

Min. 50

Nominal heat input: Natural gas - G20 I2H/I2E 2,5 - 11 kW Recommended free Nominal effect input: Propane gas - G30/G31 I3B/P(30) 2,4 - 10,8 kW convection openings Efficiency 91,5 % min. 200 cm²

DISTANCE TO FLAMMABLE MATERIAL To To To To To

Min. 1000

KEY FIGURES

105 kg Min. 1000

9 ,5

External dimensions 1036-538-804 mm Finished face opening 979,5-489-525 mm Outer frame dimensions 979,5-489-525 mm Flue outlet (diameter) Ø100 / Ø150 mm Outer diameter gas connection Ø8 mm

9

Min. 405

Nominal heat input: Natural gas - G20 I2H/I2E 1,9 - 8,8 kW free Nominal effect input: Propane gas - G30/G31 I3B/P(30) 1,8 - 8 Recommended kW convection openings Efficiency 91 % min. 200 cm²

Recommended free convection openings min. 200 cm²

525

Min. 1000

97

KEY FIGURES

13

MEASUREMENT (W-D-H)

Recommended free convection openings min. 200 cm²

Min. 525

393,5

489

54

TECHNICAL DATA:

48

Weight

RAIS VISIO 90 RC

419

449

144,5

RAIS VISIO 70 RC

323,5

937,5 **

External dimensions 826-538-684 mm Finished face opening 769,5-489-405 mm 979,5 13 Outer frame dimensions 769,5-489-405 mm Flue outlet (diameter) Ø100 / Ø150 mm Outer diameter gas connection Ø8 mm

9

RAIS Visio Gas 160-45-32 LC-6541

1637,5 **

947,5 **

MEASUREMENT (W-D-H)

,5

1692,5

992,5

TECHNICAL DATA:

78

54

Min. 50

RAIS VISIO 90/55/39 LC 1036

16

A

54

525

525

54

Ø131

C

393,5

489

144,5

54

B

979,5

Ø199

13

A

144,5

A

RAIS Visio Gas 160-45-32 LC-654201

323,5

RAIS Visio Gas 90-55-39 LC-654201

494 **

947,5 **

449

Min. 50

144,5

,5 79 .9 Min

419

.4 89

5 8, 67 .1

Mi n. 41 9

992,5

804

Min

799

538 Min

Inspection hatch

Min. 50

Min. 1000 Min. 425

54

484 **

1036

RAIS Visio Gas 16

414 **

54

A

C

Inspection hatch

C

A 1736

Min. 50

5 8, 67 .1

Mi n. 41 9

B

1692,5 C

B Min

145

0 mm 0 mm 1000 mm 150 mm 1000 mm

425

754

525

C

Min. 50

B

B

To side wall To back wall RAIS Visio Gas To 90-55-39 LC-654201 the ceiling To the floor To furniture

54 A-A

Min. 50

54

144,5

654

0 mm Ø199 0 mm Ø131 1000 mm 150 mm A-A 1000 mm

.4 89

424 **

Ø199

165 kgØ131

A DISTANCE TO FLAMMABLE MATERIAL

,5 79 .9 Min

425

Inspection hatch Min. 1000

side wall back wall the ceiling 144,5 theAfloor furniture

Min

convection openings min. 200 cm²

425

Weight

Recommended free convection openings min. 200 cm² 494 **

DISTANCE TO FLAMMABLE MATERIAL To To To To To

Min. 50

140 kg

704

Nominal heat input: Natural gas - G20 I2H/I2E 3 - 17,2 kW Nominal effect input: Propane gas - G30/G31 I3B/P(30) 2,7 - 16,5 kW Efficiency 92 % Recommended free

Min. 525

Weight

KEY FIGURES Min. 50

Nominal heat input: Natural gas - G20 I2H/I2E 2,5 - 11 kW Nominal effect input: Propane gas - G30/G31 I3B/P(30) 2,4 - 10,8 kW Efficiency 90,5 %

Recommended free convection openings min. 200 cm²

External dimensions 1736-468-704 mm Finished face opening 1678,5-419-425 mm Outer frame dimensions 1678,5-419-425 mm Flue outlet (diameter) Ø130 / Ø200 mm Outer diameter gas connection Ø10 mm

Min. 1000

External dimensions 1036-538-804 mm Finished face opening 979,5-489-525 mm Outer frame dimensions 979,5-489-525 mm Flue outlet (diameter) Ø100 / Ø150 mm Outer diameter gas connection Ø8 mm

Min. 425

MEASUREMENT (W-D-H)

C


SPECIFIKATIONER

RAIS VISIO 160 RC

RAIS VISIO 70 3S

TECHNICAL DATA:

TECHNICAL DATA: MEASUREMENT (W-D-H)

Recommended free convection openings min. 200 cm²

Min. 425

KEY FIGURES

654

145

C

Min. 50

1692,5

Min. 405

144,5

Inspection hatch B

Inspection hatch

419

.4 89

C

RAIS Visio Gas 70-43-39 3S-654201

424 **

494 **

Ø199 A-A

877

B

54

A

Ø149 484Ø** 101

787 **

767

767 ** A

54

144,5 405

145

54 414 **

16

468

78

C

C

425

145

145

C

393,5

489

54

B

684

654

425

425

C

1736

B 54

A-A

B

A

54

538

144,5

405

144,5

A

405

Ø131

634

1678,5

C

145

323,5

Min

7 87 n. Mi

405

684

RAIS Visio Gas 160-45-32 RC-654201

704

B 54

A-A

634

144,5

Ø101

767 ** A

Min. 50

9 41

n. Mi

7 87

Ø149

405

799

n. Mi

.4 89

RAIS Visio Gas 70-43-

787 **

468

1637,5 **

Min

Inspection hatch

494 **

414 **

1647,5 ** .1 67 8, 5

0 mm 0 mm 1000 mm 150 mm 1000 mm

54 1736

Min

100 kg

To side wall To back wall C the ceiling RAIS Visio GasTo160-45-32 RC-654201 To the floor To furniture

B Inspection hatch

425

n. Mi

Recommended free convection openings min. 200 cm²

DISTANCE TO FLAMMABLE MATERIAL

Min. 50 9 41

A

B Weight

54

Min. 50

A-A

Min. 50

Ø131

145

425

704

Min. 425

165 kg 144,5 A Min .1 DISTANCE TO FLAMMABLE MATERIAL 67 8, 5 To side wall 0 mm To back wall 0 mm To the ceiling 1000 mm To the floor 150 mm To furniture 1000 mm

Min. 50

Ø199

Min. 1000

Weight

Nominal heat input: Natural gas - G20 I2H/I2E 1,9 - 8,8 kW Nominal effect input: Propane gas - G30/G31 I3B/P(30) 1,8 - 8 kW Efficiency 91 %

424 **

Min. 1000

Nominal heat input: Natural gas - G20 I2H/I2E 3 - 17,2 kW Recommended Nominal effect input: Propane gas - G30/G31 I3B/P(30) 2,7 - 16,5 kW free convection openings min. 200 cm² Efficiency 92 %

Min. 405

KEY FIGURES

Recommended free convection openings min. 200 cm²

External dimensions 826-538-684 mm Finished face opening 769,5-489-405 mm Outer frame dimensions 769,5-489-405 mm Flue outlet (diameter) Ø100 / Ø150 mm Outer diameter gas connection Ø8 mm

Min. 1000

External dimensions 1736-468-704 mm Finished face opening 1678,5-419-425 mm Outer frame dimensions 1678,5-419-425 mm Flue outlet (diameter) Ø130 / Ø200 mm Outer diameter gas connection Ø10 mm

Min. 1000

MEASUREMENT (W-D-H)

A 877

,5

438,5

54

484 **

877

87 48

7

9

538

1692,5 1647,5 **

41

1637,5 ** RAIS VISIO 160/45/32 RC

9

767

RAIS VISIO 70/43/39 3S

RAIS Visio Gas 70-43-39 3S-6541

54

RAIS VISIO 160 3S

419

RAIS VISIO 90 3S

438,5

TECHNICAL DATA:

A

54 1087

.4 89

To side wall To back wall theAceiling RAIS Visio GasTo90-55-39 3S-654201 To the floor 1787 To furniture

Inspection hatch

Min

.4 89

n. Mi

144,5

Min

Min. 1000 Min. 425

7 78 .1

A-A

54

C

Ø131

1677 **

54

54

A

A-A

B

C

425

654

525

704

425

B

525

754

525

804

1087

RAIS Visio Gas 160-

RAIS Visio Gas 160-45-32 3S-654201

144,5

54

Min .4 19

424 ** Ø199

1697 **

1787

B RAIS Visio Gas 90-55-39 3S-654201

144,5

C

54

B 543,5

Inspection hatch

7 78 .1

Min .4 19

893,5

Ø199

393,5

489

C

494 ** Ø131

977 **

323,5

419

Inspection hatch

87 10

997 **

A

Min

468

484 **

977

0 mm 0 mm 1000 mm 150 mm 414 ** 1000 mm

1677

538

B

160 kg

DISTANCE TO FLAMMABLE MATERIAL

B

425425 Min.

Min. 1000

Min. 1000

Min

C

87 10 n. Mi

Weight

Min. 50

C

Inspection hatch

B

525

0 mm 0 mm 1000 mm 150 mm 1000 mm

145

side wall back wall the ceiling the floor furniture 754

To To To To To

525

804

DISTANCE TO FLAMMABLE MATERIAL

B

RAIS Visio Gas 160-45-32 RC-6541

145

54

144,5

A-A

704

135 kg

144,5

A-A

Min. 50

4

19

54

654

Ø131

977 **

131 Nominal1677 heat ** input: Natural gas - G20 I2H/I2E 3 - 17,2 ØkW 144,5 Nominal input: Propane gas - G30/G31 I3B/P(30) 2,7 - 16,5 kW A effect Efficiency 92 %

,5

Min. 1000

A

78

Min. 525

Weight

16

7

9

RAIS Visio Gas 70-43-39 3S-6541

424 ** Ø199

Recommended free convection openings min. 200 cm²

1697 ** KEY FIGURES

Min. 50

Nominal heat input: Natural gas - G20 I2H/I2E 1,9 - 8,8 kW Nominal effect input: Propane gas - G30/G31 Recommended I3B/P(30) free 1,8 - 8 kW convection openings 494 ** Ø19991 % min. 200 cm² Efficiency

Recommended free convection openings min. 200 cm²

External dimensions 1736-468-704 mm Finished face opening 1678,5-419-425 mm Outer frame dimensions 1678,5-419-425 mm Flue outlet (diameter) Ø130 / Ø200 mm Outer diameter gas connection Ø10 mm

Min. 525

425

54

KEY FIGURES

48

MEASUREMENT (W-D-H)

Recommended free convection openings min. 200 cm²

External dimensions 1036-538-804 mm Finished face opening 979,5-489-525 mm Outer frame dimensions 979,5-489-525 mm Flue outlet (diameter) Ø100 / Ø150 mm Outer diameter gas connection Ø8 mm

425

MEASUREMENT (W-D-H)

87

877

425

TECHNICAL DATA:

Min. 50

1678,5

997 **

393,5

489

405

144,5

RAIS Visio Gas 160-45-32 RC-6541

799

538

48

17

RAIS VISIO 160/45/32 3S

9

414 **

41

9

468

1677

977

87

54

1787

87

144,5

484 **

10

19

18

A

54

,5

RAIS VISIO 90/55/39 1087 3S

145

C

A

145

C

RAIS Visio Gas 160-45-32 3S-6541


SPECIFIKATIONER

RAIS VISIO 90 RD

TECHNICAL DATA:

TECHNICAL DATA: MEASUREMENT (W-D-H)

Recommended free convection openings min. 200 cm²

Nominal heat input: Natural gas - G20 I2H/I2E 2,5 - 11 kW Nominal effect input: Propane gas - G30/G31 I3B/P(30) 2,4 - 10,8 kW Efficiency 92 %

Min

0 mm 522 ** 0 mm Ø149 1000 Ø101 mm 150 mm 314,5 314,5 1000 mm

Min

Min. 1000

150 kg Recommended free convection openings min. 200 cm²

Min. 50

DISTANCE TO FLAMMABLE MATERIAL

Inspection hatch .7 32 ,5

29 .6

B

53,5

C

To side wall To back wall To theRD-654201 ceiling RAIS Visio Gas 43-49-65 1047 ** To the floor 1037 ** To furniture

Mi n.

0 mm512 ** 0 mm492 ** 1000 mmØ199 150 mmØ131 1000 mm 299,5

A

A-A

C

. Min

135 542 **

314,5

314,5

99 .5

512 **

Inspection hatch

Ø131 299,5

C

A-A

A

,5

299,5 A-A

C

599

314,5

53

RAIS Visio Gas 40-55-90 RD-654201

Ø199

1037 ** 53,5

B

492 **

1047 210 **

314,5

A

Min

1037

B RAIS Visio Gas 43-49-65 RD-654201

Ø101

797 **

599

97 2, 5

1088,5

Ø149

807 **

116

C 73

9

2,

5

135

135

C 62

A

RAIS VISIO 43/49/65 RD 848,5

548,5

548,5

972,5

52

B

838

489,5

727

778,8

4 8 9 ,5

B 115,5

299,5

629

Mi n.

9 62

522 **

733

Min. 50 548,5

Min. 548,5

Min. 50

489,5

B

299,5

181

A

Inspection hatch .7 32 ,5

Inspection hatch

B

C

629 Min

99 .5

299,5

A

807

Min

RAIS Visio Ga

135

C

848,5

97 2, 5

B

Min. 489,5

A-A

727

778,8

side wall back wall 807 ** the ceiling the floor 797 ** A furniture

Min. 1000

Recommended free convection openings min. 542200 ** cm²

DISTANCE TO FLAMMABLE MATERIAL To To To To To

Weight

125 kg

838

Min. 1000

KEY FIGURES

Nominal heat input: Natural gas - G20 I2H/I2E 2,5 - 11 kW Nominal effect input: Propane gas - G30/G31 I3B/P(30) 2,4 -10,8 kW Efficiency 91 %

Min. 489,5

KEY FIGURES

Weight

Recommended free convection openings min. 200 cm²

External dimensions 599-1088,5-838 mm Finished face opening 599-972,5-548,5 mm Outer frame dimensions 599-972,5-548,5 mm Flue outlet (diameter) Ø130 / Ø200 mm Outer diameter gas connection Ø8 mm

Min. 1000

External dimensions 629-848,5-779 mm Finished face opening 629-732,5-489,5 mm Outer frame dimensions 629-732,5-489,5 mm Flue outlet (diameter) Ø130 / Ø200 mm Outer diameter gas connection Ø8 mm

Min. 548,5

MEASUREMENT (W-D-H)

Min. 50

RAIS VISIO 70 RD

RAIS VISIO 40/55/90 RD

807

97 59

A

629

2,

5

9

599

1088,5

181

1037 210

.6 62 ,5

Min

29 .6

299,5

548,5

838

Min

29 .6

Inspection hatch

C 53

,5

300 98

810

542 **

751

Min. 50 54

135

B

135 522 **

90

66

2,

2,

5

492 **

A

5

512 **

RAIS VISIO 40/55/90 T

600

1050

181

991

14,5

RAIS VISIO 43/49/65 T

B

RAIS Visio Gas 40-55-90 T-654201

490

490

902,5

C

A

Min. 50

Min. 1000

300 A-A

RAIS Visio Gas 43-49-65 T-654201

727

Min. 549

300

B

779

Ø199 Ø131

549

.6 62 ,5

Inspection hatch

838

Min

B

A

B

53,5

RAIS Visio Gas 40-

600

314,5

A

M

0 60 in.

210 314,5

A-A

Inspection hatch

300

Min. 490

314,5 629

Ø101

RAIS Visio Gas 40-55-90

600

Min .9 02 ,5

991

Ø149

00 .6

5

135 492 ** 512 **

1050

314,5

98

0 mm 0 mm 1000 mm 150 mm 1000 mm

A

Min. 50

181

Min

A-A

To the ceiling To the floor To furniture

Min. 50

751

Min .9 02 ,5

B

300

To back wall RAIS Visio Gas 43-49-65 T-654201

Min. 1000

542 **

145 kg

300

A

To side wall

Inspection hatch

C

522 **

662,5

2,

9

549

490

Min

A 810

C

135

727

779

0 mm 0 mm 1000 mm 150 mm 1000 mm

Ø199

Ø131

DISTANCE TO FLAMMABLE MATERIAL

B

side wall back wall the ceiling the floor furniture

Nominal heat input: Natural gas - G20 I2H/I2E 2,5 - 11 kW Recommended free Nominal effect input: Propane gas - G30/G31 I3B/P(30) 2,4 - 10,8 kW convection openings Efficiency 92 % min. 200 cm²

Min. 1000

DISTANCE TO FLAMMABLE MATERIAL

97 59

KEY FIGURES

Weight RAIS Visio Gas 43-49-65 RD-6541

convection openings kgmin. 200 cm²

Min. 490

120

Min. 50

B

A-A Recommended 53,5 free

A

Min. 1000

Nominal heat input: Natural gas - G20 I2H/I2E 2,5 - 11 kW Ø149 Nominal effect input: Propane gas - G30/G31 I3B/P(30) 2,4 - 10,8 Ø101 kW Efficiency 91 % 314,5 314,5

To To To To To

5

Min. 50

KEY FIGURES

Weight

2,

116

Min. 50

73

9

972,5

External dimensions 1050-600-838 mm Finished face opening 902,5-500-549 mm Outer frame dimensions 902,5-549 mm Flue outlet (diameter) Ø130 / Ø200 mm Outer diameter gas connection Ø8 mm Min. 50

62

MEASUREMENT (W-D-H)

52

Recommended free convection openings min. 200 cm²

549

115,5

733

External dimensions 810-629-779 mm Finished face opening 662,5-529-490 mm Outer frame dimensions 662,5-490 mm Flue outlet (diameter) Ø130 / Ø200 mm Outer diameter gas connection Ø8 mm

4 8 9 ,5

MEASUREMENT (W-D-H)

,5

TECHNICAL DATA:

Recommended free convection openings min. 200 cm²

RAIS Visio Gas 40-55-90 RD-65

599

314,5

53

299,5

629

TECHNICAL DATA:

RAIS VISIO 90 T

RAIS Visio Gas 43-49-65 RD-6541

Min. 549

314,5

RAIS VISIO 70 T

RAIS Visio Gas 43-49-65 T-6541

210

19


WWW.RAIS.COM