Regufoam Brochure

Page 1

vibration and structural isolation construction/industrial products

Technical data for Regufoam® • 150 • 220 • 300 • 400 • 510 • 680


Applications

Product range

General M&E Plant ACU’s Refrigeration equipment Pumps Lift motors General workshop machinery Generators Boilers Presses Guillotines Milling machines

Regufoam® 150

Industrial Inertia plinths Machinery mounting pads/strips Foundation isolation Mass spring systems Plant rooms

Regufoam® 220

Structural engineering Isolation of steel structures Structural bearings Resilient seatings Stairs and landings

Regufoam® 300

Infrastructure Road construction Bridge construction Rail and tunnel construction Regufoam® 400

Construction Building isolation Foundation isolation Structural isolation Floating floors

Regufoam® 510

Regufoam® 680

2


Construction / Industrial Noise and vibration isolation Regufoam® is manufactured from polyurethane

Regufoam® can also be used in the following

foam and is primarily used for the isolation of

industries:

noise and vibration in building structures and permanent way systems. It is available in six

• Mechanical engineering

different densities and colour coded for ease

• Heating and ventilation

of identification. Designed to be flexible, the

• Industrial

material provides a solution that can

• Road, rail and tunnel construction

overcome the full range of anti-vibration

• Shipbuilding

challenges in the construction industry. • Automotive Regufoam® offers very high levels of vibration isolation and noise attenuation and has been specifically designed to isolate structures from ground borne noise and vibration. It also has excellent resilience with minimal creep characteristics. All Regufoam® products have been independently tested at the University of Dresden.

Load Ranges Regufoam® 0.400

Load range (N/mm2)

0.200

0.100

0.050 0.025 0.010

0.000 150

220

300

400

Regufoam® grades

3

510

680


Load Ranges Regufoam速 150 0.400

Load range (N/mm2)

0.200

0.100

0.050 0.025 0.010

0.000 150

220

300

400

510

680

Regufoam速 grades

1 Load Deflection Regufoam速 150 0.0200 25mm

12mm

37mm

0.0175

Dynamic load range*

0.0150

0.0125

0.0100

0.0075

Static load range

Load range (N/mm2)

50mm

0.0050

0.0025 Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.0000 0

1

2

3

4

5

6

7

8

9

10

Deflection (mm) Samples: 300mm x 300mm, 3rd load cycle, between flat plates Load rate: 0.02 MPa/min, ambient temperature * When calculating specifics, please do not base calculations using the dynamic load range.

4

11

12


2 Vibration Isolation Regufoam速 150 200 190 -40 dB/99%

180

-30 dB/97%

170 160 150 Disturbing frequency (Hz)

140 130 -20 dB/90%

120 110 100 90 80

-10 dB/69%

70 60 50 40

0 dB/0%

30 20 10 4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

Natural frequency (Hz) Parameter: Power transmission loss (dB), isolation factor in %

3 Natural Frequency Regufoam速 150 0.0200

0.0175

Dynamic load range

0.0125

0.0100

25mm

0.0075

Static load range

Load range (N/mm2)

0.0150

12mm

50mm 0.0050 37mm 0.0025

Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.0000 4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

Natural frequency (Hz) The diagram refers to a structure consisting of a rigid base and an elastic layer of Regufoam速 150.

5

38

40


4 Modulus of Elasticity Regufoam速 150 0.45 Static load range

Dynamic load range

0.40

0.35

Elastic modulus (N/mm2)

40 Hz 0.30

0.25

10 Hz

0.20

5 Hz

0.15

0.10

static

0.05

Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.00 0.000

0.005

0.010

0.015

0.020

Specific load (N/mm2) Static modulus of elasticity: Tangential modulus from the deflection curves Dynamic modulus: samples 300mm x 300mm x 25mm Sinusoidal excitation, amplitude +/- 0.25mm

5 Dynamic Stiffness Regufoam速 150 0.014

14

Dynamic load range

40 Hz

0.012

12

0.010

10

0.008

8

10 Hz 6

5 Hz

0.006

4

0.004

2

static

0.002

Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.000 0.000

0.005

0.010 Permanent load (N/mm2)

Samples: 300mm x 300mm x 25mm DIN 53513

6

0.015

0

0.020

Dynamic stiffness (MN/m3)

Dynamic stiffness (N/mm3)

Static load range


6 Long-term Creep Test Regufoam® 150 Relative deflection (% of thickness)

50

40

30

20 0.01 N/mm2 10

0 1

10

100

1000

10000

100000

Loading time (hrs)

Technical Data Permanent static load range: 0 to 0.010 N/mm2 Permanent and variable loads/operating load ranges: 0 to 0.015 N/mm2 Rare and short-term loads/load parts: up to 0.50 N/mm2

Physical Properties Roll dimensions*: 5m x 1.5m Standard thickness: 12mm & 25mm Material basis: Cellular Polyurethane (PUR) Mixed cell structure Colour: beige * Also available in bespoke dimensions and as moulded items

Technical Information Density

DIN 53420

ca. 150

Kg/m3

Beddings module

DIN 18134

0.0038

N/mm3

Measured at a maximum continuous load of 0.01 N/mm2 and a material thickness of 25mm.

Compression Set

DIN 53572

2.50

%

Measured 30 minutes after decompression with 50% deformation/23ºC after 70 hrs.

Tensile Strength

DIN 53571

0.42

N/mm2

Minimum

Elongation at break

DIN 53571

270

%

Minimum

Tear-Resistance

DIN 53515

2.65

N/mm

Minimum

Mechanical Loss Factor DIN 53513

0.25

Static Modulus of Elasticity

Similar to EN 826

0.025-0.16

N/mm

Dynamic Modulus of Elasticity

DIN 53513

0.11-0.32

N/mm2

– 2

Tangential modulus see fig. 4 Depending on load and frequency, see fig. 4

The information on this data sheet is based on the current state of our knowledge and experience and is subject to changes and production-related variations without notice.

7


Load Ranges Regufoam速 220 0.400

Load range (N/mm2)

0.200

0.100

0.050 0.025 0.010

0.000 150

220

300

400

510

680

Regufoam速 grades

1 Load Deflection Regufoam速 220 0.050 12mm

25mm

0.045 37mm 0.040

Dynamic load range*

0.035

0.025 0.020 Static load range

Load range (N/mm2)

50mm 0.030

0.015 0.010 0.005 Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.000 0

1

2

3

4

5

6 7 Deflection (mm)

8

9

10

Samples: 300mm x 300mm, 3rd load cycle, between flat plates Load rate: 0.05 MPa/min, ambient temperature * When calculating specifics, please do not base calculations using the dynamic load range.

8

11

12


2 Vibration Isolation Regufoam速 220 200 190 -40 dB/99%

180

-30 dB/97%

170 160 150 Disturbing frequency (Hz)

140 130 -20 dB/90%

120 110 100 90 80

-10 dB/69%

70 60 50 40

0 dB/0%

30 20 10 4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

Natural frequency of the system (Hz) Parameter: Power transmission loss (dB), isolation factor in %

3 Natural Frequency Regufoam速 220 0.050 0.045 0.040

Dynamic load range

0.030 0.025 0.020

Static load range

Load range (N/mm2)

0.035

25mm 50mm

0.015

12mm

0.010 37mm 0.005 Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.000 4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

Natural frequency (Hz) The diagram refers to a structure consisting of a rigid base and an elastic layer of Regufoam速 220.

9

38

40


4 Modulus of Elasticity Regufoam速 220 1.00 Dynamic load range

Static load range

Elastic modulus (N/mm2)

0.75

40 Hz

0.50 10 Hz 5 Hz

0.25

static

Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.00 0.00

0.01

0.02

0.03

0.04

0.05

Specific load (N/mm2) Static modulus of elasticity: Tangential modulus from the deflection curves Dynamic modulus: samples 300mm x 300mm x 25mm Sinusoidal excitation, amplitude +/- 0.25mm

5 Dynamic Stiffness Regufoam速 220 0.030

30 Dynamic load range

Static load range

0.025

25

0.020

20 10 Hz

5 Hz

0.015

0.010

15

10

static

0.005

5

Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.000 0.000

0.010

0.020

0.030

Permanent load (N/mm2) Samples: 300mm x 300mm x 25mm DIN 53513

10

0.040

0 0.050

Dynamic stiffness (MN/m3)

Dynamic stiffness (N/mm3)

40 Hz


6 Long-term Creep Test Regufoam® 220 Relative deflection (% of thickness)

50

40

30

20

0.025 N/mm2 10 Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0

1

10

100

1000

10000

100000

Loading time (hrs)

Technical Data Permanent static load range: 0 to 0.025 N/mm2 Permanent and variable loads/operating load ranges: 0 to 0.035 N/mm2 Rare and short-term loads/load parts: up to 1.0 N/mm2

Physical Properties Roll dimensions*: 5m x 1.5m Standard thickness: 12mm & 25mm Material basis: Cellular Polyurethane (PUR) Mixed cell structure Colour: purple * Also available in bespoke dimensions and as moulded items

Technical Information Density

DIN 53420

ca. 220

Kg/m3

Beddings module

DIN 18134

0.011

N/mm3

Measured at a maximum continuous load of 0.0025 N/mm2 and a material thickness of 25mm.

Compression Set

DIN 53572

<4.0

%

Measured 30 minutes after decompression with 50% deformation/23ºC after 70 hrs.

Tensile Strength

DIN 53571

0.56

N/mm2

Minimum

Elongation at break

DIN 53571

260

%

Minimum

Tear-Resistance

DIN 53515

3.38

N/mm

Minimum

Mechanical Loss Factor DIN 53513

0.20

Static Modulus of Elasticity

Similar to EN 826

0.05-0.38

N/mm

Dynamic Modulus of Elasticity

DIN 53513

0.30-0.69

N/mm2

– 2

Tangential modulus see fig. 4 Depending on load and frequency, see fig. 4

The information on this data sheet is based on the current state of our knowledge and experience and is subject to changes and production-related variations without notice.

11


Load Ranges Regufoam速 300 0.400

Load range (N/mm2)

0.200

0.100

0.050 0.025 0.010

0.000 150

220

300

400

510

680

Regufoam速 grades

1 Load Deflection Regufoam速 300 0.10 12mm

25mm

0.09 37mm

Dynamic load range*

0.08 0.07 0.06 0.05 0.04 Static load range

Load range (N/mm2)

50mm

0.03 0.02 0.01 Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.00 0

1

2

3

4

5

6 7 Deflection (mm)

8

9

10

Samples: 300mm x 300mm, 3rd load cycle, between flat plates Load rate: 0.1 MPa/min, ambient temperature * When calculating specifics, please do not base calculations using the dynamic load range.

12

11

12


2 Vibration Isolation Regufoam速 300 200 190

-40 dB/99%

180

-30 dB/97%

170 160 150

Disturbing frequency (Hz)

140 130

-20 dB/90%

120 110 100 90 80

-10 dB/69%

70 60 50 40

0 dB/0%

30 20 10 4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

Natural frequency of the system (Hz) Parameter: Power transmission loss (dB), isolation factor in %

3 Natural Frequency Regufoam速 300 0.10 0.09

Dynamic load range

0.08

0.06 0.05 0.04 25mm

Static load range

Load range (N/mm2)

0.07

12mm 0.03

50mm

0.02 37mm 0.01 Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.00 4

6

8

10

12

14

16

18 20 22 24 26 Natural frequency (Hz)

28

30

32

34

36

The diagram refers to a structure consisting of a rigid base and an elastic layer of Regufoam速 300.

13

38

40


4 Modulus of Elasticity Regufoam速 300 1.5 Static load range

Dynamic load range

Elastic modulus (N/mm2)

40 Hz 1.0 10 Hz

5 Hz

0.5

static

Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.0 0.00

0.01

0.02

0.03

0.04

0.05

0.06

0.07

0.08

0.09

0.10

Specific load (N/mm2) Static modulus of elasticity: Tangential modulus from the deflection curves Dynamic modulus: samples 300mm x 300mm x 25mm Sinusoidal excitation, amplitude +/- 0.25mm

5 Dynamic Stiffness Regufoam速 300 60

0.06 Static load range

Dynamic load range

50

0.05

40 10 Hz 30

0.03 5 Hz

20

0.02

static

0.01

10

Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.00 0.00

0.02

0.04

0.05

0.06

Permanent load (N/mm2) Samples: 300mm x 300mm x 25mm DIN 53513

14

0.08

0 0.10

Dynamic stiffness (MN/m3)

Dynamic stiffness (N/mm3)

40 Hz 0.04


6 Long-term Creep Test Regufoam® 300

Relative deflection (% of thickness)

50

40

30

20

0.05 N/mm2

10

Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0 1

10

100

1000

10000

100000

Loading time (hrs)

Technical Data Permanent static load range: 0 to 0.05 N/mm2 Permanent and variable loads/operating load ranges: 0 to 0.08 N/mm2 Rare and short-term loads/load parts: up to 2 N/mm2

Physical Properties Roll dimensions*: 5m x 1.5m Standard thickness: 12mm & 25mm Material basis: Cellular Polyurethane (PUR) Mixed cell structure Colour: turquoise * Also available in bespoke dimensions and as moulded items

Technical Information Density

DIN 53420

ca. 300

Kg/m3

Beddings module

DIN 18134

0.025

N/mm3

Measured at a maximum continuous load of 0.05 N/mm2 and a material thickness of 25mm.

Compression Set

DIN 53572

2.20

%

Measured 30 minutes after decompression with 50% deformation/23ºC after 70 hrs

Tensile Strength

DIN 53571

0.78

N/mm2

Minimum

Elongation at break

DIN 53571

240

%

Minimum

Tear-Resistance

DIN 53515

4.85

N/mm

Minimum

Mechanical Loss Factor DIN 53513

0.14

Static Modulus of Elasticity

Similar to EN 826

0.14-0.75

N/mm

Dynamic Modulus of Elasticity

DIN 53513

0.60-1.30

N/mm2

– 2

Tangential modulus see fig. 4 Depending on load and frequency, see fig. 4

The information on this data sheet is based on the current state of our knowledge and experience and is subject to changes and production-related variations without notice.

15


Load Ranges Regufoam速 400 0.400

Load range (N/mm2)

0.200

0.100

0.050 0.025 0.010

0.000 150

220

300

400

510

680

Regufoam速 grades

1 Load Deflection Regufoam速 400 0.200 12mm

25mm

0.175 37mm

Dynamic load range*

0.150

0.100

0.075

Static load range

Load range (N/mm2)

50mm 0.125

0.050

0.025 Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.000 0

1

2

3

4

5

6

7

8

9

10

Deflection (mm) Samples: 300mm x 300mm, 3rd load cycle, between flat plates Load rate: 0.2 MPa/min, ambient temperature * When calculating specifics, please do not base calculations using the dynamic load range.

16

11

12


2 Vibration Isolation Regufoam速 400 200 190

-40 dB/99%

180

-30 dB/97%

170 160 150

Disturbing frequency (Hz)

140 130

-20 dB/90%

120 110 100 90 80

-10 dB/69%

70 60 50 40

0 dB/0%

30 20 10

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

Natural frequency of the system (Hz)

Parameter: Power transmission loss (dB), isolation factor in %

3 Natural Frequency Regufoam速 400 0.200

0.175

Dynamic load range

0.125

0.100

0.075

Static load range

Load range (N/mm2)

0.150

25mm 50mm

0.050

12mm 0.025

37mm Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.000 4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

Natural frequency (Hz) The diagram refers to a structure consisting of a rigid base and an elastic layer of Regufoam速 400.

17

38

40


4 Modulus of Elasticity Regufoam速 400 3.0 Static load range

Dynamic load range

Elastic modulus (N/mm2)

2.5

2.0 40 Hz

10 Hz

1.5

5 Hz 1.0

0.5 static Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.0 0.00

0.05

0.10

0.15

0.20

Specific load (N/mm2) Static modulus of elasticity: Tangential modulus from the deflection curves Dynamic modulus: samples 250mm x 250mm x 25mm Sinusoidal excitation, amplitude +/- 0.25mm

5 Dynamic Stiffness Regufoam速 400 200

0.20 Static load range

Dynamic load range 180

0.18

160

0.16

140

0.14 0.12

120

10 Hz

0.10

5 Hz

100

0.08

80

0.06

60

0.04

40 static 20

0.02 Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.00 0.00

0.05

0.10 Permanent load (N/mm2)

Samples: 300mm x 300mm x 25mm DIN 53513

18

0.15

0 0.20

Dynamic stiffness (MN/m3)

Dynamic stiffness (N/mm3)

40 Hz


6 Long-term Creep Test Regufoam® 400 Relative deflection (% of thickness)

6 5 4 3 2

0.1 N/mm2

1 Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0

1

10

100

1000

10000

100000

Loading time (hrs)

Technical Data Permanent static load range: 0 to 0.10 N/mm2 Permanent and variable loads/operating load ranges: 0 to 0.15 N/mm2 Rare and short-term loads/load parts: up to 3.0 N/mm2

Physical Properties Roll dimensions*: 5m x 1.5m Standard thickness: 12mm & 25mm Material basis: Cellular Polyurethane (PUR) Mixed cell structure Colour: brick-red * Also available in bespoke dimensions and as moulded items

Technical Information Density

DIN 53420

ca. 400

Kg/m3

Beddings module

DIN 18134

0.037

N/mm3

Measured at a maximum continuous load of 0.10 N/mm2 and a material thickness of 25mm.

Compression Set

DIN 53572

2.40

%

Measured 30 minutes after decompression with 50% deformation/23ºC after 70 hrs.

Tensile Strength

DIN 53571

1.30

N/mm2

Minimum

Elongation at break

DIN 53571

290

%

Minimum

Tear-Resistance

DIN 53515

7.38

N/mm

Minimum

Mechanical Loss Factor DIN 53513

0.10

Static Modulus of Elasticity

Similar to EN 826

0.39-1.27

N/mm

Dynamic Modulus of Elasticity

DIN 53513

1.07-1.80

N/mm2

– 2

Tangential modulus see fig. 4 Depending on load and frequency, see fig. 4

The information on this data sheet is based on the current state of our knowledge and experience and is subject to changes and production-related variations without notice.

19


Load Ranges Regufoam速 510 0.400

Load range (N/mm2)

0.200

0.100

0.050 0.025 0.010

0.000 150

220

300

400

510

680

Regufoam速 grades

1 Load Deflection Regufoam速 510 0.50 25mm

12mm 0.45

37mm 0.40

50mm Dynamic load range*

0.30 0.25 0.20 Static load range

Load range (N/mm2)

0.35

0.15 0.10 0.05 Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.00

0

1

2

3

4

5

6 7 Deflection (mm)

8

9

10

Samples: 300mm x 300mm, 3rd load cycle, between flat plates Load rate: 0.5 MPa/min, ambient temperature * When calculating specifics, please do not base calculations using the dynamic load range.

20

11

12


2 Vibration Isolation Regufoam速 510 200 190 -30 dB / 97%

-40 dB / 99 %

180 170 160 150 Disturbing frequency (Hz)

140 130 -20 dB / 90 %

120 110 100 90

-10 dB / 69 %

80 70 60 50

0 dB / 0 %

40 30 20 10 4

6

8

10

12

14

16 18 20 22 24 26 28 Natural frequency of the system (Hz)

30

32

34

36

38

40

Parameter: Power transmission loss (dB), isolation factor in %

3 Natural Frequency Regufoam速 510 0.50 0.45 0.40 25mm

Dynamic load range

0.30 0.25 0.20 50mm Static load range

Load range (N/mm2)

0.35

0.15 0.10 12mm 37mm 0.05 Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.00 4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

Natural frequency (Hz) The diagram refers to a structure consisting of a rigid base and an elastic layer of Regufoam速 510.

21

38

40


4 Modulus of Elasticity Regufoam速 510 5 Static load range

Dynamic load range

40 Hz

4 5 Hz Elastic modulus (N/mm2)

10 Hz 3

2

static

1

Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0 0.00

0.1

0.2

0.3

0.4

0.5

Specific load (N/mm2) Static modulus of elasticity: Tangential modulus from the deflection curves Dynamic modulus: samples 300mm x 300mm x 25mm Sinusoidal excitation, amplitude +/- 0.25mm

5 Dynamic Stiffness Regufoam速 510 0.22

220

Dynamic load range

Static load range

200

0.20 40 Hz

180

0.18

160

10 Hz

140

0.14 5 Hz 0.12

120

0.10

100

0.08

80

static

0.06

60

0.04

40 20

0.02 Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.00 0.00

0.10

0.20

0.30

Permanent load (N/mm2) Samples: 300mm x 300mm x 25mm DIN 53513

22

0.40

0 0.50

Dynamic stiffness (MN/m3)

Dynamic stiffness (N/mm3)

0.16


6 Long-term Creep Test Regufoam® 510 Relative deflection (% of thickness)

50

40

30

0.2 N/mm2

20

10

0

1

10

100

1000

10000

100000

Loading time (hrs)

Technical Data Permanent static load range: 0 to 0.2 N/mm2 Permanent and variable loads/operating load ranges: 0 to 0.3 N/mm2 Rare and short-term loads/load parts: up to 4.0 N/mm2

Physical Properties Roll dimensions*: 5m x 1.5m Standard thickness: 12mm & 25mm Material basis: Cellular Polyurethane (PUR) Mixed cell structure Colour: orange * Also available in bespoke dimensions and as moulded items

Technical Information Density

DIN 53420

ca. 510

Kg/m3

Beddings module

DIN 18134

0.072

N/mm3

Measured at a maximum continuous load of 0.20 N/mm2 and a material thickness of 25mm.

Compression Set

DIN 53572

2.80

%

Measured 30 minutes after decompression with 50% deformation/23ºC after 70 hrs.

Tensile Strength

DIN 53571

1.50

N/mm2

Minimum

Elongation at break

DIN 53571

260

%

Minimum

Tear-Resistance

DIN 53515

8.28

N/mm

Minimum

Mechanical Loss Factor DIN 53513

0.10

Static Modulus of Elasticity

Similar to EN 826

1.49-2.25

N/mm

Dynamic Modulus of Elasticity

DIN 53513

2.63-3.35

N/mm2

– 2

Tangential modulus see fig. 4 Depending on load and frequency, see fig. 4

The information on this data sheet is based on the current state of our knowledge and experience and is subject to changes and production-related variations without notice.

23


Load Ranges Regufoam速 680 0.400

Load range (N/mm2)

0.200

0.100

0.050 0.025 0.010

0.000 150

220

300

400

510

680

Regufoam速 grades

1 Load Deflection Regufoam速 680 0.8

25mm

12mm 0.7

37mm 0.6 Dynamic load range*

0.4

0.3 Static load range

Load range (N/mm2)

50mm 0.5

0.2

0.1 Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.0 0

1

2

3

4

5 6 7 Deflection (mm)

8

9

10

Samples: 250mm x 250mm, 3rd load cycle, between flat plates Load rate: 0.8 MPa/min, ambient temperature * When calculating specifics, please do not base calculations using the dynamic load range.

24

11

12


2 Vibration Isolation Regufoam速 680 200 190 -40 dB/99%

180

-30 dB/97%

170 160 150 Disturbing frequency (Hz)

140 130 -20 dB/90%

120 110 100 90

-10 dB/69%

80 70 60 50 40

0 dB/0%

30 20 10 4

6

8

10

12

14

16

18 20 22 24 26 28 Natural frequency of the system (Hz)

30

32

34

36

38

40

Parameter: Power transmission loss (dB), isolation factor in %

3 Natural Frequency Regufoam速 680 0.8

0.7

Dynamic load range

0.5

0.4

0.3

0.2

Static load range

Load range (N/mm2)

0.6

25mm

50mm

12mm 37mm

0.1

Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.0 4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

Natural frequency (Hz) The diagram refers to a structure consisting of a rigid base and an elastic layer of Regufoam速 680.

25

38

40


4 Modulus of Elasticity Regufoam速 680 9 Dynamic load range

Static load range 8

40 Hz 7

Elastic modulus (N/mm2)

10 Hz 6 5 Hz 5

4 static 3

2

1 Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0 0.0

0.2

0.4

0.6

0.8

Specific load (N/mm2) Static modulus of elasticity: Tangential modulus from the deflection curves Dynamic modulus: samples 250mm x 250mm x 25mm Sinusoidal excitation, amplitude +/- 0.25mm

5 Dynamic Stiffness Regufoam速 680 400

0.40 Dynamic load range

Static load range

350

0.35 40 Hz

Dynamic stiffness (N/mm3)

10 Hz 250

0.25 5 Hz 0.20

200

0.15

150 static

0.10

100

0.05

50 Tested by the University of Dresden, Institute for Structural Dynamics, test certificate no. 32/02, April 2002

0.00 0.00

0.20

0.40 Permanent load (N/mm2)

Samples: 250mm x 250mm x 25mm DIN 53513

26

0.60

0 0.80

Dynamic stiffness (MN/m3)

300

0.30


6 Long-term Creep Test Regufoam® 680 Relative deflection (% of thickness)

50

40

30

20

0.4 N/mm2 10

0

1

10

100

1000

10000

100000

Loading time (hrs)

Technical Data Permanent static load range: 0 to 0.4 N/mm2 Permanent and variable loads/operating load ranges: 0 to 0.6 N/mm2 Rare and short-term loads/load parts: up to 5.0 N/mm2

Physical Properties Roll dimensions*: 5m x 1.5m Standard thickness: 12mm & 25mm Material basis: Cellular Polyurethane (PUR) Mixed cell structure Colour: brown * Also available in bespoke dimensions and as moulded items

Technical Information Density

DIN 53420

ca. 680

Kg/m3

Beddings module

DIN 18134

0.327

N/mm3

Measured at a maximum continuous load of 0.40 N/mm2 and a material thickness of 25mm.

Compression Set

DIN 53572

2.90

%

Measured 30 minutes after decompression with 50% deformation/23ºC after 70 hrs.

Tensile Strength

DIN 53571

2.47

N/mm2

Minimum

Elongation at break

DIN 53571

310

%

Minimum

Tear-Resistance

DIN 53515

14.4

N/mm

Minimum

Mechanical Loss Factor DIN 53513

0.08

Static Modulus of Elasticity

Similar to EN 826

3.0-3.9

N/mm

Dynamic Modulus of Elasticity

DIN 53513

4.80-5.60

N/mm2

– 2

Tangential modulus see fig. 4 Depending on load and frequency, see fig. 4

The information on this data sheet is based on the current state of our knowledge and experience and is subject to changes and production-related variations without notice.

27


Also in the RAME anti-vibration portfolio: Regupol® Regupol® products are high performing yet cost effective anti-vibration materials. With a high load bearing capacity and excellent damping properties, Regupol® maintains its performance over a long lifespan. Manufactured from polyurethane bound rubber granulate, all Regupol® materials are fully recyclable. A wide choice of Regupol® grades are available, which includes products with a load bearing range up to and including 1.5N/mm2. The selection of Regupol® materials will depend on a number of factors, including load, area and natural frequency. Supplied in easy to lay rolls or individually cut pads/strips, Regupol® is quick and easy to install. Construction Building isolation Foundation isolation Structural isolation Resilient seatings Floating floors Stairs and landings Industrial Inertia plinths Machinery mounting pads/strips Machine foundations Mass spring systems Plant rooms General workshop machinery

General M&E plant ACU’s Refrigeration equipment Pumps Lift motors Generators Boilers Presses Guillotines Milling machines Infrastructure Rail and tunnel construction Road and bridge construction

Regupol Acoustics Middle East (RAME) is the Middle East arm of market-leading Regupol® manufacturer, BSW. Providing exclusive access to the full range of Regupol® and Regufoam® high performance anti-vibration systems, RAME is setting the standard for vibration control in the Middle East. From specification through to project completion, RAME has a fully trained technical team able to provide free advice and on-site support as well as guidance during installation. This combined product and service offering has led to Regupol® being used on a number of high profile projects, including Dubai Healthcare City and the Marina Hotel, Abu Dhabi. For further information and advice, please contact the RAME technical sales team.

Regupol Acoustics Middle East FZE P.O. Box 125279, Dubai, UAE Phone: +971-4-3233493 Fax: +971-4-3406295 info@regupolacousticsmiddleeast.com BSW and BSW product portfolio certified by DIN EN ISO 9001 DIN EN ISO 14001 OHSAS 18001 Regupol® and Regufoam® are official trademarks of BSW

www.regupolacousticsmiddleeast.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.