2013
ROS iluminación presents its new LED solution LEDing, solutions designed to be adapted to any of our luminaries and with the possibility of being installed in already existing luminaries to maximize the efficiency of operative installations (RETROFIT). • Elimination of shadows from classic line luminaries with the NSS solution (No Shadows System).
• Possibility of customized light distribution with Custom LEDing: under specific requirements, we design one LEDing adapted to the environment needs. • High efficiency and durability thanks to a maximum heat dissipation through CRS (Cooling ROS System). • Maximum LED protection: if by mistake a luminaire is switched on, power supply current decreases a 50% if LED temperature exceeds 80ºC, or the luminaire switches off if LED temperature exceeds 95ºC.
• An LED is by-passed if it fails, so only the damaged LED switches off, not the luminaire or any LED row. • MaxControl lenses designed to optimize the luminous flux toward the area to illuminate and so a maximum energetic efficiency is achieved.
• Lenses closure PLS (Protect Lent System) which protect them and LEDs against dirtiness and against possible acts of vandalism. • Nice white light, high color rendition without glares with 4000K LEDs *.
ROS iluminación presenta sus nuevas soluciones LED LEDing, soluciones diseñadas para adaptarse a toda nuestra gama de luminarias y con posibilidad de incorporarse en luminarias ya existentes para maximizar la eficiencia de instalaciones en funcionamiento (RETROFIT). • Eliminación de las sombras de las luminarias clásicas con la solución NSS (No Shadows System). • Posibilidad de distribuciones lumínicas a medida con Custom LEDing: bajo unos requerimientos específicos, diseñamos un LEDing adaptado a las necesidades del entorno. • Gran eficiencia y alta durabilidad gracias a una máxima disipación del calor a través del CRS (Cooling ROS System). • Máxima protección del LED: si por error la luminaria se enciende durante el día, la corriente de alimentación disminuye a un 50% si la temperatura del LED excede los 80ºC, o bien se apaga la luminaria si excede los 95ºC. • Si un LED falla este se cortocircuita. Es decir, solo el LED dañado se apaga; no la luminaria ni la línea de LED entera. • Lentes MaxControl diseñadas para optimizar el flujo luminoso hacia la zona necesaria y conseguir así una máxima eficiencia energética. • Cierre de lentes PLS (Protect Lent System) para proteger a estas y los LEDs de la suciedad y de posibles actos vandálicos. • Luz blanca agradable, reproducción cromática alta y sin deslumbramientos con LEDs de 4.000K *. * Other values, as 3000K, 3500K or 5000K, also available. * Otros valores, como 3000K, 3500K o 5000K, también disponibles.
4 STREET LIGHTNING SOLUTIONS / SOLUCIONES EN ALUMBRADO PÚBLICO www.rosiluminacion.com
Composition Composición
1
CRS
Cooling ROS System Sistema ROS de disipación
2
LED’s
White light 4.000K * Luz blanca 4.000K *
3
MaxControl
Lens Lentes 4
2
High-Performance LED Alto rendimiento LED High-performance and high luminous efficacy, with nice white light 4.000K *. If one LED fails the current is by-passed therefore avoiding the luminaire (or a LED row) from switching off. LEDs de alto rendimiento y gran eficacia lumínica, con una luz blanca agradable de 4.000K *. Si un LED falla este se cortocircuita, evitando así que se apague la luminaria o la línea de LEDs.
* Other values, as 3000K, 3500K or 5000K, also available. * Otros valores, como 3000K, 3500K o 5000K, también disponibles.
PLS
Protecting Lens System Cierre de Lentes
1
CRS COOLING REFRIGERACIÓN CRS Maximum durability and luminous flux maintenance. Máxima durabilidad y mantenimiento de flujo luminoso.
3
MaxControl LENSES LENTES MaxControl
Light control, energetic efficiency and visual comfort. Control de la luz, eficiencia energética y confort visual.
Polar Diagram / Diagrama polar BADILA 50W LED
4
PLS CLOSURE CIERRE PLS
Protection of damages caused by dirtiness and anti-vandal protection. Protección de desperfectos por suciedad y protección antivandálica.
STREET LIGHTNING SOLUTIONS / SOLUCIONES EN ALUMBRADO PÚBLICO www.rosiluminacion.com
Thermographic images of luminaire STIL Imágenes termográficas de la Luminaria STIL
5
LEDing allows
HIGH-PERFORMANCE of luminaires. ALTO RENDIMIENTO de luminarias. Performance LUMINAIRES:
Rendimiento LUMINARIAS:
Efficiency: Eficacia: Standards: Normas:
75-94%
As standard LEDs are used: Como LEDs estándar se utilizan:
98,6 lm/W IP66 CE & ROHS
Maximum current
1,5A
Working current
700mA *
Color temperature
4000K *
CRI
70
Luminous efficiency
98,6 lm/w
Electrical resistance
9 ºC/w
Power
2,08 w/LED
LED depreciation curves versus running time depending on ambient temperature, powered with 700mA current. Diagramas curvas de depreciación de los LEDs alimentados a 700mA según temperatura ambiente.
STANDARDIZED LUMINOUS FLUX FLUJO LUMINOSO NORMALIZADO
* Other values under request and previous study. * Otros valores bajo demanda y previo estudio. 100%
10ºC 25ºC
50%
35ºC
0%
1k
10k
100k
RUNNING HOURS HORAS DE FUNCIONAMIENTO
Thermal pad 25ºC Manta térmica a 25ºC
Typical Relative Luminous Flux vs Forward Current for 4100K Neutral-White, 5650K Cool-White, 2700K, 3000K, 3500K, 4000K and 5000K Emitters. Thermal Pad Temperature=25ºC. Flujo luminoso relativo vs corriente directa para emisores blanco-neutro 4100K, blanco-frío 5650K, 2700K, 3000K, 3500K, 4000K y 5000K. Manta térmica 25ºC.
I (mA)
T=3500K T=4000K T=5000K Lm/LED
Lm/LED
Lm/LED
350
103
114
111
700
185
205
200
IRC
80
70
80
1.6 1.4
RELATIVE LUMINOUS FLUX FLUJO LUMINOSO RELATIVO
STREET LIGHTNING SOLUTIONS / SOLUCIONES EN ALUMBRADO PÚBLICO www.rosiluminacion.com
Technical Specifications Especificaciones Técnicas
1.2 1.0 0.8 0.6 0.4 0.2 0
0
200
400
600
800
1000
1200
FORWARD CURRENT [mA] CORRIENTE DIRECTA [mA]
Typical Relative Luminous Flux vs Temperature for 4100K Neutral-White, 5650K Cool-White, 2700K, 3000K, 3500K, 4000K and 5000K Emitters at Test Current. Flujo luminoso relativo vs temperatura para emisores blanco-neutro 4100K, blanco-frío 5650K, 2700K, 3000K, 3500K, 4000K y 5000K.
1.2
RELATIVE LUMINOUS FLUX FLUJO LUMINOSO RELATIVO
6
1.0
0.8
0.6
2700K, 3000K, 3500K, 4000K, 4100K, 5000K 5650K Cool-White
0.4
0.2
0
-20
0
20
40
60
80
100
THERMAL PAD TEMPERATURE [ºC] TEMPERATURA DE LA MANTA TÉRMICA [ºC]
120
140
1
CRS COOLING REFRIGERACIÓN CRS
COOLING ROS SYSTEM Heat sink of aluminum sheet that maximizes the durability of the light source. High-performance heat dissipation system with ventilation grids. Aluminum support plate that ensures heat transfer to the luminaire housing and interior and exterior IP66 protection. It maximizes luminous flux maintenance. SISTEMA DE REFRIGERACIÓN ROS Disipador de plancha de aluminio que maximiza la durabilidad de la fuente de luz. Sistema de disipación de calor de alto rendimiento con rejillas de ventilación. Placa soporte de aluminio que garantiza transferencia de calor a la carcasa de la luminaria y un grado de estanqueidad IP66 interior y exterior. Maximiza el mantenimiento de flujo luminoso.
3
MaxControl LENSES LENTES MaxControl
LIGHT CONTROL, ENERGETIC EFFICIENCY AND VISUAL COMFORT Optical system composed of high efficiency lenses that maximize light control increasing road illuminance and reducing glare, lighting pollution and obtrusive light out of the area to illuminate. CONTROL DE LA LUZ, EFICIENCIA ENERGÉTICA Y CONFORT VISUAL Sistema óptico compuesto de lentes de alta eficiencia que maximizan el control de la luz aumentando la iluminancia en calzada y reduciendo el deslumbramiento, la contaminación luminosa y la luz intrusa fuera de las zonas a iluminar.
4
PLS CLOSURE CIERRE PLS
PROTECT LENT SYSTEM VANDAL-PROOF, LOW AND EASY MAINTENANCE. Closure made of high impact resistance acrilic, with antiabrasion coating. Resistant against UV light and any chemical cleaning product. SISTEMA DE PROTECCIÓN DE LENTES ANTI-VANDÁLICO, BAJO Y FÁCIL MANTENIMIENTO. Cierre en metacrilato de alto impacto, con recubrimiento antiabrasión. Resistente a luz UV y cualquier producto químico de limpieza.
STREET LIGHTNING SOLUTIONS / SOLUCIONES EN ALUMBRADO PÚBLICO www.rosiluminacion.com
CRS for CLASSIC luminaire LRA/F-05. CRS para modelo CLASSIC LRA/F-05.
7
8 STREET LIGHTNING SOLUTIONS / SOLUCIONES EN ALUMBRADO PÚBLICO www.rosiluminacion.com
Remote Management and Control Functions Telegestión y Funciones de Control ROS INTELLIGENT REMOTE MANAGEMENT
Intelligent luminaires for an integral remote management service: Optimization of Street Lighting logistic by means of intelligent luminaires with bidirectional capacity: capacity to receive and send information through a control center. Action by point to point or by groups of luminaires.
CONTROL FUNCTIONS
Wide variety of control options of operating parameters: CONSTANT OUT FLUX.
All light sources undergo some depreciation of the output flux along time. To ensure illumination levels required in the installation, most light studies are based on the value of flux at the end of lamp life, which means an unnecessary extra consumption at the beginning. The constant out flux function compensates the gradual depreciation of the LED flux so that the working flux value is the required one.
FLUX CONTOL in 5 steps.
This feature lets to program up to 5 periods during the night, giving each one the duration and percentage of luminous flux desired according to service needs of the installation.
FLUX CONTROL in two steps by means of an external signal line. For simpler applications, the flux regulation to one single reduced level can be accomplished by signal line.
ADJUSTABLE TIME.
Unlike discharge lamps, LEDs turn on almost instantly, which can be uncomfortable for the users. This feature allows scheduling a gradual switching on increasing the light of the LED to the service level.
FLUX CONT ROL by means of 1-10V digital signal. This option allows gradual adjustment between 10% and 100% of output power of the system, connecting the luminaire to a 1-10V system controller device thus applying continued regulation.
DALI PROTOCOL.
An acronym for Digital Addressable Lighting Interface, this concept supports the intelligent system management. By means of this communication protocol, it is possible the interaction between elements such as sensors, switches, etc., elements that can be involved in a complex installation.
TELEGESTIÓN ROS INTELLIGENT
Luminarias inteligentes para un servicio de telegestión integral: Optimización logística del Alumbrado Público mediante luminarias inteligentes con capacidad bidireccional:
capacidad de recepción y envío de información a través de un centro de control. Actuación punto por punto o por grupo de luminarias.
FUNCIONES DE CONTROL
Amplia variedad de posibilidades de control de parámetros de funcionamiento: Toda fuente de luz experimenta cierta depreciación en su flujo emitido en el tiempo. Para asegurar los niveles de iluminación requeridos en la instalación, la mayoría de proyectos de iluminación están basados en el valor de flujo al final de la vida de la lámpara, lo cual significa un consumo extra inicial innecesario. La función flujo de salida constante permite compensar la depreciación gradual de flujo de los LED de manera que el valor del flujo de trabajo sea el requerido.
REGULACIÓN de FLUJO hasta 5 niveles. Esta función permite programar hasta 5 períodos durante la noche, asignando a cada uno el valor de duración y porcentaje de flujo luminoso deseados según necesidades de servicio de la instalación.
REGULACIÓN de FLUJO a dos niveles mediante línea de mando.
Para aplicaciones más sencillas, la regulación de flujo a un único nivel de
flujo reducido se puede llevar a cabo mediante señal de línea.
TIEMPO de ENCENDIDO AJUSTABLE.
A diferencia del cómo enciende una lámpara de descarga, el LED enciende de manera prácticamente instantánea, lo cual puede resultar incómodo para los usuarios de la instalación. Esta función permite programar un encendido gradual incrementando la luminosidad de los LED hasta el nivel de servicio.
REGULACIÓN DE FLUJO mediante señal digital 1-10V.
Esta opción permite regulación gradual entre el 10% y el 100% de la potencia de salida del sistema, mediante la conexión de la luminaria a un dispositivo controlador con sistema 1-10V aplicando de esta manera regulación continuada.
PROTOCOLO DALI.
Acrónimo de Digital Adressable Lighting Interface, este concepto soporta la gestión inteligente del sistema. Mediante este protocolo de comunicación se hace posible la interacción entre elementos como la luminaria, sensores, interruptores, etc, elementos que puedan intervenir y actuar en el seno de una instalación compleja.
STREET LIGHTNING SOLUTIONS / SOLUCIONES EN ALUMBRADO PÚBLICO www.rosiluminacion.com
FLUJO de SALIDA CONSTANTE.
9
10
BADILA LRA-7500 Luminaire Luminaria
SOLUCIONES STREET LIGHTNING EN ALUMBRADO SOLUTIONSPÚBLICO / SOLUCIONES / STREET ENLIGHTNING ALUMBRADO SOLUTIONS PÚBLICO www.rosiluminacion.com
Luminaire with perfect integration in all kind of urban environments thanks to its neutral design. The use of LEDing solution with MaxControl technology allows BADILA to illuminate any place with the maximum efficiency.
Luminaria de líneas suaves y neutras para una perfecta integración en todos los entornos urbanos. La incorporación de la solución LEDing con la tecnología MaxControl permite alumbrar todo tipo de viales con la máxima eficiencia.
Efficiency: Rendimiento: General Protection: Protección General: Optic group Protection: Protección grupo óptico: Protection Impacts: Protección Impactos: Standards: Normas:
94% IP65 IP66 IK08 CE ROHS
Example of lighting values in a typical road. Caso ejemplo de valores de iluminación en vial tipo.
BADILA LED 100W 24 LED / 2x50W
VALUES VALORES
1
ME3a Class, Road: Clase ME3a, Calzada: Lm = 1cd/m2 UL = 0,7 ≥ 0,7 UO = 0,5 ≥ 0,4 TI = 9,84% ≤ 15% SR = 0,56 > 0,50
2 1 2
3
Adjacent sidewalk: Acera adyacente:
7,9m
Em = 14 lux Um = 0,63 > 0,40
3
Opposite sidewalk: Acera opuesta: Em = 10 lux Um = 0,68 > 0,40
1,5m
7,0m
1,5m
30,0m
BADILA LED 50W
UTILIZATION FACTOR DIAGRAM
Thermographic images of luminaire BADILA Imágenes termográficas de la Luminaria BADILA
General Characteristics Características Técnicas Upper and lower housing made of die cast aluminium.
Cuerpo superior e inferior de aluminio inyectado.
Lateral holder for side fixation.
Zócalo de fijación lateral de la luminaria.
Non-loosening stainless steel lock screw.
Cierre, formado por tornillo imperdible de acero inoxidable.
Hinge set for housing opening. Security bar permits 70º position.
Eje-bisagra para abertura de los cuerpos superior e inferior. Sistema de seguridad anti-cierre fijando la apertura a 70°.
Metal frame for control gear Protection of optical group: IP-66. Electrical protection: Class II. Stainless steel screws.
www.rosiluminacion.com
ISOLUX CURVE
STREET LIGHTNING SOLUTIONS SOLUCIONES EN ALUMBRADO PÚBLICO
POLAR DIAGRAM
Bastidor metálico para alojamiento del equipo de control. Protección grupo óptico: IP-66. Protección eléctrica: Clase II. Tornillería auxiliar en acero inoxidable.
11
12
NAIA LRA-7700 Luminaire Luminaria
SOLUCIONES STREET LIGHTNING EN ALUMBRADO SOLUTIONSPÚBLICO / SOLUCIONES / STREET ENLIGHTNING ALUMBRADO SOLUTIONS PÚBLICO www.rosiluminacion.com
Design and efficiency meet each other in this luminaire thanks to its minimalist lines and the incorporation of LEDing technology. Designed for avenues, urban and residential areas, the incorporation of MaxControl solution allows NAIA to meet any specific lighting requirement.
Luminaria de líneas rectas y minimalistas para alumbrar zonas en las que se busque eficiencia y diseño. Diseñada para grandes vías, zonas urbanas y áreas residenciales, la incorporación de la solución MaxControl permite a NAIA iluminar cualquier vial sea cual sea el requerimiento.
Efficiency: Rendimiento: General Protection: Protección General: Optic group Protection: Protección grupo óptico: Protection Impacts: Protección Impactos: Standards: Normas:
95% IP66 IP66 IK10 CE ROHS
Example of lighting values in a typical road. Caso ejemplo de valores de iluminación en vial tipo.
NAIA LED 50W 24 LED / 1x50W
VALUES VALORES
1
ME3a Class, Road: Clase ME3a, Calzada: Lm = 0,71cd/m2 UL = 0,71 ≥ 0,5 UO = 0,47 ≥ 0,4 TI = 9,27% ≤ 15% SR = 0,52 > 0,50
2 1 3
2
Adjacent sidewalk: Acera adyacente:
7,0m
Em = 9 lux Um = 0,69 > 0,40
3
Opposite sidewalk: Acera opuesta: Em = 6 lux Um = 0,72 > 0,40
7,0m
1,4m
25,0m
General Characteristics Características Técnicas Luminaire made of injected aluminum.
Luminaria construida en aluminio inyectado.
Its housing is composed of two main parts, lower and upper, with opening system on the lower one, to accede to internal components.
Formada por dos cuerpos, inferior y superior, con apertura del cuerpo inferior para el acceso a los componentes interiores.
Heat sink action is made through the upper part as the LED optics is attached to it, under optimized heat cooling conditions.
Unión al soporte, brazo o columna, por su parte posterior a un diámetro de 60mm en el caso de fijación lateral y 60 o 76mm en el caso de fijación inferior.
The assembly to the support (bracket or pole) is made through its rear side against diameter 60mm when fixed to lateral supports and diameter 60mm or 76mm for post top poles.
Distribución asimétrica de la luz, preferente en el plano C0º-C180º, adecuada para la iluminación vial con elevada uniformidad, tanto de luminancias como de iluminancias, gracias a la óptica que incorpora, fabricada de PMMA de baja absorción, dando un magnífico resultado tanto en distribución, emisión de flujo emitido en el hemisferio superior como en deslumbramiento.
Asymmetrical light distribution, mainly on plane C0ºC180º, suitable for road lighting with high uniformity, either from luminance or illuminance, due to its optics made of low absorption PMMA, giving great results regarding to distribution, upper light output rate, as well as dazzle. Protecting rate: IP-66. Electrical protection: Class I. Protection against mechanical impacts: IK-10.
Protección general: IP-66 Protección grupo óptico: IP-66 Protección eléctrica: Clase I
STREET LIGHTNING SOLUTIONS / SOLUCIONES EN ALUMBRADO PÚBLICO www.rosiluminacion.com
1,4m
Protección contra impactos: IK-10
13
14
CLASSIC LRA-05 Luminaire Luminaria
SOLUCIONES STREET LIGHTNING EN ALUMBRADO SOLUTIONSPÚBLICO / SOLUCIONES / STREET ENLIGHTNING ALUMBRADO SOLUTIONS PÚBLICO www.rosiluminacion.com
Luminaire with classic lines to fit in historical towns where efficiency is a must. The use of LEDing solution with MaxControl and NSS technologies allows CLASSIC illuminate with both efficency and visual confort.
Luminaria de líneas clásicas para los centros históricos que buscan máxima eficiencia. La luminaria CLASSIC incorpora la tecnología MaxControl y NSS que permite iluminar zonas históricas, residenciales y parques con la mayor eficiencia y confort visual.
Efficiency: Rendimiento: General Protection: Protección General: Optic group Protection: Protección grupo óptico: Protection Impacts: Protección Impactos: Standards: Normas:
76% IP44 IP66 IK08 CE ROHS
Example of lighting values in a typical road. Caso ejemplo de valores de iluminación en vial tipo.
CLASSIC LED 30W 24 LED / 1x30W
VALUES VALORES
1
S1 Class, Road: Clase S1, Calzada: Em = 15 lux Emin = 9 lux Um = 0,59 ≥ 0,40
2
2 1
Adjacent sidewalk: Acera adyacente: Em = 12 lux Um = 0,72 > 0,40
3 3
4,0m
Opposite sidewalk: Acera opuesta: Em = 7 lux Um = 0,64 > 0,40
1,5m
3,5m
1,5m
14,0m
CLASSIC LED 50W
UTILIZATION FACTOR DIAGRAM
General Characteristics Características Técnicas Main housing comprising:
Armadura principal formada por:
Lower and upper body plus cast aluminium socket made of cast aluminium (references LRA/F) or zn steel sheet (ref. LRA/L).
Cuerpo inferior y superior más zócalo, en fundición de aluminio (refs. LRA/F) o en plancha de acero cincado (refs. LRA/L).
Spun aluminium dome.
Cúpula superior de plancha de aluminio repulsado.
Methacrilate diffusers, transparent or frosted.
Difusores de metacrilato, grabados o transparentes.
Metal frame for control gear.
Bastidor metálico para alojamiento del equipo de control.
Closing by special stainless steel screw, operable with a simple tool.
Cierre mediante tornillo inoxidable especial, accionable con herramienta simple.
Hinged turning system made of stainless steel.
Ejes de basculación de acero inoxidable.
Access to lamps and equipment by opening the upper body over the lower body.
Acceso a lámparas y equipos por basculación entre los cuerpos superior e inferior.
General protection: IP-44
Protección general: IP-44
Optical unit protection: IP-66, Class I
Protección grupo óptico: IP-66, Clase I
Auxiliar screws in stainless steel.
Tornillería auxiliar de acero inoxidable.
Decorative elements in brass.
Adornos de latón.
www.rosiluminacion.com
ISOLUX CURVE
STREET LIGHTNING SOLUTIONS SOLUCIONES EN ALUMBRADO PÚBLICO
POLAR DIAGRAM
15
16
STIL LRA-65 Luminaire Luminaria
SOLUCIONES STREET LIGHTNING EN ALUMBRADO SOLUTIONSPÚBLICO / SOLUCIONES / STREET ENLIGHTNING ALUMBRADO SOLUTIONS PÚBLICO www.rosiluminacion.com
Classic-styled luminaire for a perfect integration in historical centers. Updated with the new LEDing to obtain high efficiency and durability. Distribution with MaxControl technology and NSS (No Shadow System) to avoid shadows due to the luminaire itself.
Luminaria de estilo clásico para una perfecta integración en los centros históricos. Actualizada con el nuevo LEDing para obtener una alta eficiencia y durabilidad. Distribución con tecnología MaxControl y NSS (No shadows System) para evitar las sombras debidas a la propia luminaria.
Efficiency: Rendimiento: General Protection: Protección General: Optic group Protection: Protección grupo óptico: Protection Impacts: Protección Impactos: Standards: Normas:
75% IP44 IP66 IK08 CE ROHS
Example of lighting values in a typical road. Caso ejemplo de valores de iluminación en vial tipo.
STIL LED 50W 24 LED / 1x50W
VALUES VALORES
1 CE2 Class, Road: Clase CE2, Calzada: Em = 20 lux Emin = 11 lux Um = 0,54 ≥ 0,40
3
2 1
Adjacent sidewalk: Acera adyacente:
2
Em = 14 lux Um = 0,42 > 0,40
3,8m
3 Opposite sidewalk: Acera opuesta: Em = 14 lux Um = 0,42 > 0,40 1,5m
6,0m
1,5m
30,0m
STIL LED 50W
UTILIZATION FACTOR DIAGRAM
Thermographic images of luminaire STIL Imágenes termográficas de la Luminaria STIL
General Characteristics Características Técnicas Upper dome, made of spun aluminium, plus decorative upper and lower coronas made of cast aluminium, with stainless steel locking system. Lower housing composed by half corona, vertical supports and bottom base, all they made of cast aluminium. Methacrylate transparent or frosted diffusers. Metal frame for control gear. General protection: IP-44, Optical unit protection: IP-66 Class I Auxiliar screws in stainless steel. Decorative elements in brass.
Cuerpo superior formado por cúpula de aluminio repulsado; semicorona y corona superior ambas realizadas en fundición de aluminio con sistema de cierre imperdible de acero inoxidable. Cuerpo inferior formado por semicorona, bajantes y zócalo base, todos ellos en fundición de aluminio. Difusores de metacrilato transparente o grabado
www.rosiluminacion.com
ISOLUX CURVE
STREET LIGHTNING SOLUTIONS SOLUCIONES EN ALUMBRADO PÚBLICO
POLAR DIAGRAM
Bastidor metálico para alojamiento del equipo de control. Protección general: IP-44 Protección grupo óptico: IP-66, Clase I Tornillería auxiliar de acero inoxidable. Adornos de latón.
17
18
PICASSO LRA-55 Luminaire Luminaria
SOLUCIONES STREET LIGHTNING EN ALUMBRADO SOLUTIONSPÚBLICO / SOLUCIONES / STREET ENLIGHTNING ALUMBRADO SOLUTIONS PÚBLICO www.rosiluminacion.com
PICASSO Led is designed to keep the aesthetics of some traditional light fittings, with the LEDing solution efficiency. MaxControl technology used in PICASO is designed to be applied in parks, residential and pedestrian areas.
La luminaria PICASSO Led permite mantener la estética característica de puntos de luz históricos con la eficiencia de la solución LEDing. La tecnología MaxControl que incorpora PICASSO está especialmente diseñada para alumbrar zonas peatonales, residenciales y jardines.
Efficiency: Rendimiento: General Protection: Protección General: Optic group Protection: Protección grupo óptico: Protection Impacts: Protección Impactos: Standards: Normas:
86% IP44 IP66 IK08 CE ROHS
Example of lighting values in a typical road. Caso ejemplo de valores de iluminación en vial tipo.
PICASSO LED 50W 24 LED / 1x50W
VALUES VALORES
1
S1 Class, Road: Clase S1, Calzada: Em = 15 lux Emin = 9 lux Um = 0,57 ≥ 0,40
2 2
1
Adjacent sidewalk: Acera adyacente: Em = 14 lux Um = 0,49 > 0,40
3 3
4,5m
Opposite sidewalk: Acera opuesta: Em = 7,5 lux Um = 0,75 > 0,40
1,0m
6,0m
1,0m
18,0m
PICASSO LED 50W
UTILIZATION FACTOR DIAGRAM
Thermographic images of luminaire PICASSO Imágenes termográficas de la Luminaria PICASSO
General Characteristics Características Técnicas Methacrylate high impact diffusser frosted.
Difusor de metacrilato (alta resistencia al impacto) grabado.
Upper dome made of aluminium, removable.
Cúpula superior de aluminio extraíble.
Base made of aluminium as common support for: optical kit, diffuser, dome and frame.
Base de aluminio unificando y soportando: grupo óptico, difusor, cúpula y bastidor.
Internal pipe for electrical wire; twin pipes to make easier wiring when using bipowered control gear.
Tubo conductor para el cable de alimentación; doble tubo para mayor facilidad de cableado con el uso de equipos de doble régimen de potencia.
Decorative device to fix the upper dome. Reinforcement ring made of aluminium. General protection: IP-44 Optical unit protection: IP-66, Class I Stainless steel screws.
Adorno / dispositivo de fijación de la cúpula.
www.rosiluminacion.com
ISOLUX CURVE
STREET LIGHTNING SOLUTIONS SOLUCIONES EN ALUMBRADO PÚBLICO
POLAR DIAGRAM
Aro de refuerzo de aluminio. Protección general: IP-44. Protección grupo óptico: IP-66, Clase I Tornillería auxiliar en acero inoxidable.
19
20
EPSILON LRA-8000 Luminaire Luminaria
SOLUCIONES STREET LIGHTNING EN ALUMBRADO SOLUTIONSPÚBLICO / SOLUCIONES / STREET ENLIGHTNING ALUMBRADO SOLUTIONS PÚBLICO www.rosiluminacion.com
Luminaire with perfect integration in parks, residential and pedestrian areas due to its neutral design. The use of LEDing solution with MAXcontrol and NSS technologies allows EPSILON illuminate with the maximum efficiency and visual comfort.
Luminaria de líneas suaves y neutras para una perfecta integración en zonas peatonales, paseos, zonas residenciales y jardines. La incorporación de la solución LEDing con a tecnología MaxControl y NSS permite alumbrar con la máxima eficiencia y confort visual.
Efficiency: Rendimiento: General Protection: Protección General: Optic group Protection: Protección grupo óptico: Protection Impacts: Protección Impactos: Standards: Normas:
88% IP44 IP66 IK08 CE ROHS
Example of lighting values in a typical road. Caso ejemplo de valores de iluminación en vial tipo.
EPSILON LED 30W 24 LED / 1x30W
VALUES VALORES
1
ME4b Class, Road: Clase ME4b, Calzada: Lm = 0,87cd/m2 UL = 0,72 ≥ 0,5 UO = 0,63 ≥ 0,4 TI = 5,98% ≤ 15% SR = 0,51 > 0,50
3 1 2
2
Adjacent sidewalk: Acera adyacente:
5,5m
Em = 14 lux Um = 0,41 > 0,40
3
Opposite sidewalk: Acera opuesta: Em = 10 lux Um = 0,41 > 0,40
1,5m
7,0m
1,5m
25,0m
EPSILON LED 50W
UTILIZATION FACTOR DIAGRAM
General Characteristics Características Técnicas Upper housing cover of die cast aluminium.
Cuerpo superior de fundición de aluminio inyectado.
Lower base of die cast aluminium.
Cuerpo inferior de fundición de aluminio inyectado.
Cast aluminium lower support for connecting and fixing to posts.
Brazo de fundición de aluminio para acoplar y fijar el conjunto a los soportes.
Non loosening locking screw made of stainless steel easy to operate with simple tool.
Tornillo de cierre de acero inox, e imperdible por mecanizado especial; accionable con herramienta simple.
Hinge set for opening of upper cover.
Conjunto de eje y bisagra, para basculación y apertura de los cuerpos entre sí.
A fastening system, in stainless steel, which fully guarantees opening at an angle of 70º. Control gear plate in steel zinc coated. Optical unit protection: IP-66, Class II Auxiliar screws in stainless steel.
Un sistema de tijera, garantiza con total seguridad la apertura en un ángulo de 70º. Bastidor para la fijación de accesorios y equipos de encendido. Protección grupo óptico: IP-66, Clase II Tornillería auxiliar de acero inoxidable.
www.rosiluminacion.com
ISOLUX CURVE
STREET LIGHTNING SOLUTIONS SOLUCIONES EN ALUMBRADO PÚBLICO
POLAR DIAGRAM
21
22
REAL LRA-8500 Luminaire Luminaria
SOLUCIONES STREET LIGHTNING EN ALUMBRADO SOLUTIONSPÚBLICO / SOLUCIONES / STREET ENLIGHTNING ALUMBRADO SOLUTIONS PÚBLICO www.rosiluminacion.com
Fits in any environment, either classic or contemporary, due to the mixin of classic and modern design. MaxControl technology used in REAL is designed to give a solution in any the urban environment.
Luminaria apta para cualquier entorno, histórico o moderno, gracias a su diseño clásico con líneas actuales. La luminaria REAL con tecnología MaxControl está diseñada para dar solución a cualquier entorno urbano.
Efficiency: Rendimiento: General Protection: Protección General: Optic group Protection: Protección grupo óptico: Protection Impacts: Protección Impactos: Standards: Normas:
89% IP44 IP66 IK08 CE ROHS
Example of lighting values in a typical road. Caso ejemplo de valores de iluminación en vial tipo.
REAL LED 50W 24 LED 1x50W
VALUES VALORES
1
ME4b Class, Road: Clase ME4b, Calzada: Lm = 1,04cd/m2 UL = 0,64 ≥ 0,5 UO = 0,66 ≥ 0,4 TI = 6,78% ≤ 15% SR = 0,52 > 0,50
2 1 3
2
Adjacent sidewalk: Acera adyacente:
6,0m
Em = 14 lux Um = 0,51 > 0,40
3
Opposite sidewalk: Acera opuesta: Em = 14 lux Um = 0,51 > 0,40
2,0m
10,5m
2,0m
23,0m
REAL LED 50W
UTILIZATION FACTOR DIAGRAM
General Characteristics Características Técnicas Decorative cast aluminium corona with spun aluminium dome.
Corona de fundición de Al y cúpula de aluminio repulsado.
Lower housing made of die cast aluminium.
Cáncamo y bulón de fijación, con paso interior de cable.
Hanging fixation system, with internal conduction for electrical wire. Non-loosening stainless steel lock screw. Hinge set for housing opening. Security bar permits 70º position. Metal frame for control gear. Transparent polymethacrylate diffuser. High impact resistance. Upper decotarive corona made of cast aluminium. Cast Al. lower support for connecting and fixing to posts. Protection of optical group: IP-66. Electrical protection: Class II. Stainless steel screws.
Cuerpo inferior de aluminio inyectado. Cierre, formado por tornillo imperdible de acero inoxidable. Eje-bisagra para abertura de los cuerpos superior e inferior. Bastidor metálico para alojamiento del equipo de control Difusor de metacrilato transparente de alta resistencia a los impactos. Corona superior de fundición de aluminio. Brazo inferior en “V” de fundición de aluminio para acoplar y fijar el conjunto a los soportes. Protección grupo óptico: IP-66. Protección eléctrica: Clase II. Tornillería auxiliar en acero inoxidable.
www.rosiluminacion.com
ISOLUX CURVE
STREET LIGHTNING SOLUTIONS SOLUCIONES EN ALUMBRADO PÚBLICO
POLAR DIAGRAM
23
24
CUSTOM
STREET LIGHTNING SOLUTIONS / SOLUCIONES EN ALUMBRADO PÚBLICO www.rosiluminacion.com
Customized Solutions Soluciones Personalizadas CUSTOM LEDing Any solution with no limits. The engineering department of ROS iluminación modifies LEDing to give the best solution to the specific needs of each environment.
CUSTOM LEDing Cualquier solución sin límites. El departamento de ingeniería de ROS iluminación aplica modificaciones a medida sobre LEDing para dar la mejor solución a las necesidades particulares de cada entorno.
STIL LED 50W CUSTOM LEDing
POLAR DIAGRAM
ISOLUX CURVE
UTILIZATION FACTOR DIAGRAM
CLASS CE1A Em = 24,7 lux Emin = 13,1 lux Um = 0,53
9,0m
1,0m
CUSTOM LEDing study on STIL LRA-75 luminaire September 2012
9,0m
Estudio CUSTOM LEDing sobre luminaria STIL LRA-75 Septiembre 2012
STREET LIGHTNING SOLUTIONS / SOLUCIONES EN ALUMBRADO PÚBLICO www.rosiluminacion.com
4,0m
25
26 STREET LIGHTNING SOLUTIONS / SOLUCIONES EN ALUMBRADO PÚBLICO www.rosiluminacion.com
Adapting LEDing Adaptación LEDing
RETROFIT
LEDing RETROFIT
LEDing RETROFIT
Steps
Pasos
1 Lighting study to check the viability and improvements that LED incorporation supposes to an already existing installation.
1 Estudio luminotécnico para comprobar la viabilidad y las mejoras que suponen la incorporación del LED a una instalación en funcionamiento.
2 Study of the luminaire by ROS technical services: - Verification of the correct heat dissipation to guarantee LED’s life. - Volume restrictions test. - Design of the required mechanical solution.
2 Estudio de la luminaria por parte de los Servicios técnicos de ROS, para: - Comprobación de la correcta disipación de la temperatura para asegurar la vida del LED. - Análisis de restricciones de espacios. - Diseño de la solución mecánica a adoptar.
Giving a second life to the luminaires by adapting LEDing to equipment currently installed.
3 Study and preparation of the budget.
Segunda vida a las luminarias mediante la adaptación de LEDing a material actualmente instalado.
3 Estudio y preparación del presupuesto.
27
STREET LIGHTNING SOLUTIONS / SOLUCIONES EN ALUMBRADO PÚBLICO www.rosiluminacion.com
SOLUCIONES EN ALUMBRADO PÚBLICO STREET LIGHTNING SOLUTIONS www.rosiluminacion.com ros@rosiluminacion.com
R. ROS ALGUER, S.A. Dr. Almera, 30 08205 SABADELL Barcelona (SPAIN)
Tel. +34 937263799* Fax +34 937260200