NEW
AGILIUM®
High performance drainage system
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 1
01/09/2023 10:19
AGILIUM® ALMOST AS GOOD FOR THE BODY AS IT IS FOR THE PLANET
* 30% is the average weight reduction compared to the range. ** 20% is the reduction of CO2 emissions at the production stage, compared to the standard range (according to the respective EPDs).
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 2
01/09/2023 10:19
SUMMARY INTRODUCTION
4
01 - NEW AGILIUM®
6
02 - PERFORMANCE
10
03- PRODUCT RANGE
16
• AGILIUM® increased ease of installation • The result of eco-design
• Fire safety • Durability • Acoustic comfort • Environmental impact
8 9
12 14 14 15
• Offer and compatibility • BIM • Overall dimensions • Coating • Product marking • AGILIUM® range
18 18 19 19 20 21
OUR SERVICES
23
PAM Building 3
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 3
01/09/2023 10:19
PAM BUILDING For 150 years, we have been designing, manufacturing and marketing high-quality complete systems for sanitary and rainwater drainage in buildings. We work exclusively with cast iron, a noble and durable material, of which we are specialists and market leaders.
Our mission: the safety and durability of buildings Our cast iron solutions and systems contribute to ensure the comfort, safety and durability of the most demanding residential and commercial buildings. Their exceptional characteristics allow them to contribute to HQE, BREEAM, LEED and other international environmental certifications.
Our technical team is available from the conception to the realization of a project. Our business managers ensure a daily follow-up on the ground and guarantee the best conditions for implementation. Our products, our people and all our teams are here to help you make the world a more beautiful and sustainable home together.
Our greatest strength : our teams We rely on our technical know-how in order to remain the forerunners in our field. This is why PAM Building capitalizes on the skills of its teams and integrates every year young graduates, in apprenticeship or in advanced training. Thanks to our unique commercial approach, we have become a technical solutions provider able to anticipate our customers’ expectations.
4 PAM Building
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 4
01/09/2023 10:19
Our promise: to reduce our impact on the environment Our 2025 vs. 2010 goals:
- 40 % of
energy consumption
- 97 % of discharges
of industrial water
Our commitment to reducing C02 emissions by 203 :
- 80% compared to 2017 At the heart of the circular economy, our DNA: recycling of metal waste Our products are made of 99% recycled materials (mainly scrap metal), which can be recycled 100% indefinitely. Cast iron is a simple and sustainable material that allows a smart reuse of materials. Resistant, reliable and durable, cast iron has a bright future ahead of it. In 2021, we recycled the equivalent of of 21,000 cars.
- 84 % of non-
recovered waste
SAFE AND SUSTAINABLE BY NATURE
PAM Building 5
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 5
01/09/2023 10:19
01 NEW AGILIUM® INCREASED EASE OF INSTALLATION, 100% COMPATIBLE WITH EXISTING RANGES AND STILL AS EFFICIENT AS EVER
6 PAM Building
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 6
01/09/2023 10:19
01 NEW AGILIUM®
PAM Building 7
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 7
01/09/2023 10:19
NEW AGILIUM® PAM Building launches a new drainage solution that reduces its environmental impact and facilitates the daily work of installers. An innovation that is part of our eco-design approach.
For plumbers
For design offices
For project owners
Easier to carry with a weight reduction of 30 %. Faster to install with less time spent on pipe handling.
More agility with a space-saving in increasingly more constrained spaces.
Better for the environment with a 20% reduction in carbon emissions.
SEE PAGE 19
SEE PAGE 15
SEE PAGE 18
AGILIUM®: INCREASED EASE OF INSTALLATION, 100% COMPATIBLE WITH EXISTING RANGES AND STILL AS EFFICIENT.
Fire resistance
Durability
Acoustic comfort
Environment
Agilium® cast iron is a non-combustible metallic material with reaction to fire A1 and fire resistant up to 4 hours to protect people and property.
Due to their exceptional mechanical properties cast iron drainage systems prevent the worry of untimely and costly repairs.
Agilium® cast iron is made from recycled materials and is 100% recyclable. It reduces C02 emissions by 20%.
SEE PAGE 12
SEE PAGE 14
Noise is bad for your health. Agilium® cast iron systems easily meet the regulatory requirements, achieving exceptional performance for high acoustic comfort (luxury hotels, hospitals...)..
SEE PAGE 15
SEE PAGE 14
8 PAM Building
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 8
01/09/2023 10:19
THE RESULT OF AN ECO-DESIGN Evolution of the EN877 standard
The de Lavaud process
The NF EN877 standard is evolving and allows to reduce the minimum thickness of the walls. The products carry the NF quality mark, which means that the conformity of the products has been verified by a third party.
A unique manufacturing process, optimized for Agilium®, with investments partly supported by the Grand Est region.
DN
Minimum wall thickness (mm)*
100
2,0
125
2,5
150
2,5
200
3,0
250
3,5
300
4,0
In the de Lavaud process, historically developed by Saint-Gobain, the liquid metal is poured into a bare steel shell and undergoes very rapid cooling.
A graphitization annealing process, followed by ferritization, results in pipes with exceptional mechanical properties.
* Minimum value of wall thickness up to -1 mm, by comparison with Table 6 of the NF EN877 standard.
PAM Building 9
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 9
01/09/2023 10:19
02 PERFORMANCE FIRE SAFETY LONGEVITY ACOUSTIC COMFORT ENVIRONMENTAL IMPACT
10 PAM Building
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 10
01/09/2023 10:19
02 PERFORMANCE
PAM Building 11
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 11
01/09/2023 10:19
AGILIUM® Agilium® complies with the new standard EN877 and maintains equivalent performance to our current cast iron drainage solutions.
We have conducted numerous tests in accredited European laboratories and in our R&D center, which confirm the excellent performance of Agilium® cast iron.
FIRE SAFETY Pipes are the arteries of a building. In the event of a fire, the risk is that these pipes will sustain and spread the fire throughout the building. Choosing PAM Building cast iron systems means ensuring the safety of people and property.
Reaction to fire • Reaction to fire is the ability to ignite and to feed the fire. • Agilium® drainage systems are A1 fire rated and completely non-combustible. They do not generate smoke or droplets in case of fire. The Euroclasses establish a classification of reaction to fire that are harmonized throughout Europe that can be used to compare materials and product performance.
EUROCLASSES A1
-
-
A2
s1
d0
s1
d1
A2 A2
B
s2 s3 s1
d0
s2
d1
s3 C
s1
d0
s2
d1
s3 D
s1
d0
s2
d1
Criteria PRODUCTION of SMOKE s1 : Low production of smoke s2 : Medium production of smoke s3 : High production of smoke Criteria MOLTEN DROPLETS d0 : No molten droplets d1 : Molten droplets that persist for less than than 10 s d2 : Molten droplets
s3 Classes other than E-d2 & F
12 PAM Building
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 12
01/09/2023 10:19
Fire resistance • The fire resistance of a product is its ability to resist fire for a given time and not transmit the fire to an adjacent room. • Agilium® cast iron is a non-combustible metallic material with a melting point higher than than 1000°C.
Fire resistance test results. Following fire resistance tests carried out by Efectis on slab and wall penetrations, in the vast majority of cases, no protection is necessary. To answer to local regulations in some countries, and for specific configurations, we also tested multiple firewall solutions, like: • Optimization of the thickness of the slab by adding concrete blocks at the level of the crossing. • In some cases, because the fire resistance classification implies a limitation of the heating on the side opposite the fire, insulation in the area of the penetration is necessary, carried out by the use of mineral wool shells.
Fire resistance tests carried out by Efectis.
PAM Building 13
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 13
01/09/2023 10:19
DURABILITY AND MECHANICAL STRENGTH Reduced maintenance costs due to the mechanical properties of cast iron. Aging behaviour: cast iron is characterized by a long life span of 70 years, in particular thanks to the stability of its mechanical properties, in comparison with the aging of polymers and their deterioration.
Agilium® Process
Other processes
(not PAM Building)
Provision of the European standard EN877
Tensile strength on specimen in MPa (average values)
310
270
200 minimum
Crushing strength on ring in MPa (average values, DN 100 pipe)
515
360
350 minimum
Brinell surface hardness in degrees HB (average values)
165
245
260 maximum
Resistance of Agilium® cast iron to impacts occurring in parking lots and basements in technical rooms (cellars, garbage rooms...).
ACOUSTIC COMFORT FOR THE OCCUPANTS Agilium® retains the acoustic performance with an airborne sound insulation of La,A 46dB(A) according to the EN 14366 standard, for a discharge flow of 2.0 l/s. (Test report P-BA6/2021E, tests performed at the Fraunhofer Institute). Unlike other materials, the acoustic performance of Agilium® cast iron is guaranteed: • Without technical advice. • Without addition of specific parts. • Without specific assembly (gluing, welding, etc...)
14 PAM Building
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 14
01/09/2023 10:19
ENVIRONMENTAL IMPACT Agilium® is our first eco-design, in line with our new environmental roadmap.
The plumbing package at building level The plumbing package represents less than 5% of a building’s C02 emissions (data from life cycle analysis), according to a sensitivity study conducted in France by the Bastide Bondoux, Pouget and Tribu design offices, on a 4-story office building (4,000 m2). With Agilium®, it is possible to go even further.
20% less CO2 emissions with Agilium®, compared to our current ranges This performance is validated by comparing our new Agilium® Environmental Product Declaration (EPD) with the one previously available on the environdec database (www.environdec.com).
STANDARD
11,2kg C02 eq/UF*
<5% OF CONTRIBUTION
TO CO2 EMISSIONS FROM OF SANITARY EQUIPMENT AT THE BUILDING LEVEL
AGILIUM®
8,9kg C02 eq/UF*
*UFC = Functional Unit = 1 ml of drainage system
And still unbeatable in terms of circular economy!
99% RECYCLABLE 100%
RECYCLED
Tower Saint-Gobain certified BREEAM, LEED, HQE and effinergie using PAM Building drainage solutions. PAM Building.
PAM Building 15
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 15
01/09/2023 10:19
03 PRODUCT RANGE OFFER AND COMPATIBILITY BIM DIMENSIONS COATING PRODUCT MARKING AGILIUM® RANGE
16 PAM Building
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 16
01/09/2023 10:19
03 PRODUCT RANGE
PAM Building 17
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 17
01/09/2023 10:19
PRODUCT RANGE A complete new offer with 24 new references (pipes and fittings) to replace the current range.
PIPE
FITTINGS
-30% lighter*
-15% lighter*
6 references, from DN100 to DN300 (see page 21)
WIDE RANGE OF PRODUCTS AND COMPATIBILITY • You can mix Agilium® pipes with fittings. • You can mix pipes of the standard range with Agilium® fittings. • You can use most standard joints. • You can keep most of the reservations for standard range with Agilium®.
Agilium® Fittings
NEW LIBRARY OF BIM OBJECTS • Revit format. • Coexistence with the old library.
LIFE OF D EN FEASIBILITY
TI RA OPE
Standard range Fittings
Standard range Pipe
* Average weight reduction compared to the Ensign range.
O N
BIM R E A DY
DESIGN
Agilium® Pipe
18 references (see pages 21 - 22)
RENOVA TIO N
• Average reduction of 30% compared to the standard range. • A 3 m Agilium® DN100 pipe weighs just 17 kg, compared to 24 kg for the standard range. • The outer diameter is maintained. • Slight increase in inner diameter.
N IO CONSTRUCT
18 PAM Building
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 18
01/09/2023 10:19
SHORTER FITTINGS REQUIRING LESS SPACE IN THE VOID • Reduced sealing zone at the ends. • External diameter maintained. • Weight reduction* 15% on average.
STANDARD RANGE
In the example above the footprint is reduced by 2.3 cm. Contact us for other configurations.
COATING Pipes 1
Exterior coating red brown acrylic primer with an average dry film thickness of 40 microns.
1
2
Cast iron manufactured according to the de Lavaud process.
2
Interior lining: Two-component epoxy coating, ochre color, average dry film thickness 130 microns. 3
Fittings
3
Exterior and interior coating in red brown epoxy with an average thickness of 70 microns.
PAM Building 19
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 19
01/09/2023 10:19
PRODUCT MARKING - PIPES Product name
Classification of reaction to fire
Compliance to the standard
For easy visual differentiation in the warehouse and on the construction site
Compliance Dimension to the NF mark of the pipe
Country of origin
EAN code for simplified inventory management
• Blue marking. • Blue ring at the end of each pipe.
PRODUCT MARKING - FITTINGS EAN code label for simplified inventory management
20 PAM Building
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 20
01/09/2023 10:19
AGILIUM® - PIPE DN
L
H
W
Weight
Product Code
100
3000
110
110
16,8
283723
125
3000
135
135
24,8
283724
150
3000
160
160
30,5
283725
200
3000
210
210
46,3
283726
250
3000
274
274
66,4
283727
300
3000
326
326
86,7
283728
Check availability with your distributor or PAM Building contact.
L
H
W
AGILIUM® - FITTINGS 45° and 88° Angle
45°
88°
DN
L
H
W
a
q
Weight
Product Code
100
139
149
110
65
72
1,3
283867
125
167
175
135
75
80
2,0
285291
150
194
197
160
83
85
3,0
285292
200
253
254
210
106
106
5,4
285293
100
160
162
110
103
52
1,8
283868
125
190
192
135
120
57
2,8
285294
150
223
225
160
140
65
4,4
285295
Check availability with your distributor or PAM Building contact.
q
L
H
H
a
q
a
L
a W
W
a
PAM Building 21
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 21
01/09/2023 10:19
AGILIUM® - FITTINGS Single branches to 45° and 88° Angle
DN
dn
100 125
45°
88°
100
H
W
b
c
o
p
q
r
Weight
Product Code
100
223
245
110
185
185
60
230
152
35
3,3
283869
100
248
255
135
202
202
53
234
157
40
4,3
285296
125
270
291
135
220
220
71
283
178
40
5,3
285297
100
278
277
160
222
227
55
253
176
50
5,7
285358
150
200
L
125
295
308
160
238
238
70
285
190
50
6,7
285298
150
323
342
160
260
265
82
324
212
45
8,0
285299
100
327
291
210
256
260
35
257
180
60
8,2
285300
150
369
362
210
294
295
68
332
220
55
11,3
285301
200
410
429
210
327
329
103
408
260
55
14,9
285302
100
165
206
110
98
108
108
167
57
34
2,5
283870
Check availability with your distributor or PAM Building contact. L
H
p
H
b
b
L
W
p
W
r
r
o
q
c
o
q
c
Double branches at 45° Angle
DN
dn
L
H
W
b
c
d
p
q
r
Weight
Product Code
45°
100
100
337
245
110
185
185
60
230
152
35
4,14
283871
W
r
d
c
q
p
H
b
L
22 PAM Building
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 22
01/09/2023 10:19
OUR SERVICES TO PROFESSIONALS BIM CATALOGUE Design your projects with BIM. PAM Building is fully committed to this new way of thinking about construction and to the new working methods induced by BIM. We provide you with our own PAM Building cast iron library (in REVIT format) for the representation of sanitary and rainwater evacuation networks. Register now and upload BIM files and objects on the BIM Library: bimlibrary.saint-gobain.com/en/France On the use of BIM for PAM Building products: access our tutorials on our YouTube channel.
TECHNICAL SUPPORT Our portfolio of services is constantly adapting to the new expectations of design offices and plumbing companies working on construction projects of safe, comfortable and durable buildings. If you have any questions, please contact our experts.
PAM Building 23
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 23
01/09/2023 10:19
www.pambuilding.com
21 avenue Camille Cavallier - BP 129 • 54705 • PONT-À-MOUSSON Cedex • France Tél : +33(0)3 83 80 67 89
01/09/2023 10:19
STGOB-ADV025856 AGILIUM-BROCHURE A4-24P-UK INTER 2023-V5.indd 24
Décembre 2022 • Les photos et les illustrations utilisées dans ce document ne sont pas contractuelles. Toute reproduction, même partielle des diagrammes, photos et textes de ce document est interdite sans l’autorisation de Saint-Gobain PAM Bâtiment (Loi du 11 mars 1957). SAINT-GOBAIN PAM Bâtiment - SAS au capital de 6 812 970,75 € - SIRET 79928388200030 - RCS Nancy B 799283882 Réalisation : - Photos : DR, ©Istock, ©Shutterstock, ©Saint-Gobain PAM Bâtiment. Tous droits réservés.
PAM Building