Preparation of DPR for construction of shopping complex at Old district hospital site, BT road, Imphal, Manipur Design and Development of Shops inside mall using, Bamboo
( Locally available Material). Conceptual Stage
West Bengal
Proposed Extension of HUDCO Regional office building at Salt lake , Kolkata
Design of Guard Room Plans/ Elevations/ Sections
Jammu and Kashmir
Proposed Vertical Housing Colony-Shehjar Apartments at Bemina, Sri Nagar
.Site Layout using 2BHK & 3BHK Towers Different Scenarios and multiple permutations and combinations.
.Detailed area calculations ---FAR, Greens and open area on site, Parking , Density….
. Design and Development of Community Hall ---Plans/ Elevations Conceptual stage
.Design and development of 2BHK & 3BHK layouts and elevations and sections.
.Design and Development of Twin towers Plan and elevations----Conceptual stage
.Kitchen and Bathroom Layouts 2and 3BHK units
Manipur
Design and Development of Shops inside mall using Bamboo. Plan Elevation Section
CONCEPTUAL STAGE-01
BAMBOO
BRICK PERFORATION
PREPARATION OF DPR FOR CONSTRUCTION OF SHOPPING COMPLEX AT OLD DISTRICT HOSPITAL SITE, B.T. ROAD, IMPHAL, MANIPUR
2
Design and Development of Guard room Plan
Elevation
Section
Kolkata
SCHEDULE OF OPENINGS
• Development of Layout –using a combination of 15, 16 , 17 and 18 Towers.
• Community Hall
Plan
Elevation
Section
• 2BHK –Different Options/ s+7/11/12
Plan
Elevation
Section
Kitchen and Bathroom detail
• 3BHK –Different Options/ s+7/11/12
Plan
Elevation
Section
Kitchen and Bathroom detail
Jammu and Kashmir
parameters
CONCEPTUAL PLAN OF 15 TOWERS
EXISTING 2BHK AND 3BHK TOWER
PROPOSED 2BHK TOWER
PROPOSED 3BHK TOWER
REMARKS
1. TOTAL PLOT AREA 45145.8 SQ.M
2. EXISTING 2BHK AND 3BHK TOWERS (S+7) 2+3= 5
3. PROPOSED 2BHK AND (3X2=6) +(2x2=4)=10 3BHK TWIN TOWERS(S+12) (2 NOs. OF 2BHK TWIN TOWERS) (3NOs. OF 3BHK TWIN TOWERS)
4. TOTAL NO. OF TOWERS (EXISTING AND PROPOSED) (5+10)=15
5. TOTAL NO. OF 2BHK DUs 192+56=248
6. TOTAL NO. OF 3BHK DUs 288+84=372
7. TOTAL NO. OF DUs. 620
8. FAR (INCLUDING STAIRCASE USED AS FIRE ESCAPE) 1.71
9. ORGANISED OPEN SPACE 6775.6 SQ.M 15.00 % OF SITE AREA)
AS PER SRINAGAR MASTERPLAN 2035 MINIMUNM ORGANISED GREEN SPACE REQUIRED-15%
1. Provision of fire escape staircase and lift shall be finalised in consultation with services consultant.
2. Parking has been calculated on the basis of FAR area (including fire escape).As per Srinagar MP 2035, parking is to be provided @1ECS/100 sqm which calculates to 744 car parking requirement. However as per SDA, since the commercial and club facilities/community block are to be used by ONLY residents of the colony, exclusive parking for these ameneties has not been considered.Car baysize of 2.75x5.00m has been adopted as per NBC 2016.
3. SDA MP 2035 mentions 15% of organised green area. Organized open space for hilly areas in URDPFI guidelines mentions Housing area park requirement of 0.5 to 1 Ha for5000 population as per which approx.12 % of open space may fit the norms which SDA may explore.
PROJECT :
PROPOSED VERTICAL HOUSING COLONYSHEHJAR APARTMENTS AT BEMINA , SRINAGAR , J & K
parameters
CONCEPTUAL PLAN OF 17 TOWERS
EXISTING 2BHK AND 3BHK TOWER PROPOSED 2BHK TOWER
PROPOSED 3BHK TOWER
REQUIRED DISTANCE BETWEEN THE TOWERS IS 13MTRS.
1. TOTAL PLOT AREA 45145.8 SQ.M
2. EXISTING 2BHK AND 3BHK TOWERS (S+7) 2+3= 5
3. PROPOSED 2BHK AND 6X2=12 3BHK TWIN TOWERS(S+12) (3NOs. OF 2BHK TWIN TOWERS) (3NOs. OF 3BHK TWIN TOWERS)
4. TOTAL NO. OF TOWERS (EXISTING AND PROPOSED) (5+12)=17
5. TOTAL NO. OF 2BHK DUs 288+56=344
6. TOTAL NO. OF 3BHK DUs 288+84=372
7. TOTAL NO. OF DUs. 716
8. FAR (INCLUDING STAIRCASE USED AS FIRE ESCAPE) 1.94
9. ORGANISED OPEN SPACE 5995.35 SQ.M 13.27 % OF SITE AREA)
10. PARKING REQUIRED 848
PARKING PROVIDED 431(surface)+222(stilts) TOTAL PARKING PROVIDED 653
PARKING GAP 195
NOTE :
REMARKS AS PER SRINAGAR MASTERPLAN 2035 MINIMUNM ORGANISED GREEN SPACE REQUIRED-15%
1. Provision of fire escape staircase and lift shall be finalised in consultation with services consultant.
2. Parking has been calculated on the basis of FAR area (including fire escape).As per Srinagar MP 2035, parking is to be provided @1ECS/100 sqm which calculates to 850 car parking requirement. However as per SDA, since the commercial and club facilities/community block are to be used by ONLY residents of the colony, exclusive parking for these ameneties has not been considered.Car baysize of 2.75x5.00m has been adopted as per NBC 2016.
3. SDA MP 2035 mentions 15% of organised green area. Organized open space for hilly areas in URDPFI guidelines mentions Housing area park requirement of 0.5 to 1 Ha for5000 population as per which approx.12 % of open space may fit the norms which SDA may explore.
PROJECT :
PROPOSED VERTICAL HOUSING COLONYSHEHJAR APARTMENTS AT BEMINA , SRINAGAR , J & K
LEGENDS
CONCEPTUAL PLAN OF 16 TOWERS
EXISTING 2BHK AND 3BHK TOWER
PROPOSED 2BHK AND 3BHK COMBINED TOWER
PROPOSED 3BHK SINGLE TOWERS
1. TOTAL PLOT AREA 45145.SQM
2. EXISTING 2BHK TOWERS (S+7) 2
3. EXISTING 3BHK TOWERS(S+7) 3
4. PROPOSED 2BHK AND 5X2=10 3BHK COMBINED TOWERS(S+12) each tower comprises of 8DUs
5. PROPOSED 3BHK SINGLE TOWERS (S+12) 1
6. TOTAL NO. OF TOWERS (EXISTING AND PROPOSED) 16
7. TOTAL NO. OFF DUs. 668
8. FAR (INCLUDING STAIRCASE USED AS FIRE ESCAPE) 1.72
9. ORGANISED OPEN SPACE 5459.6 SQ.M (12.09% OF SITE AREA)
10. PARKING REQUIRED 745
PARKING PROVIDED 745
PARKING GAP 0
NOTE :
REMARKS
as per srinagar masterplan 2035 parking is to be provided @1ecs/100 the parking slots for facilities are not considered in the calculations for total parking required AS PER SRINAGAR MASTERPLAN 2035 MINIMUNM ORGANISED GREEN SPACE REQUIRED-15%
1. Provision of fire escape staircase and lift shall be finalised in consultation with services consultant.
2. Parking has been calculated on the basis of FAR area (including fire escape).As per Srinagar MP 2035, parking is to be provided @1ECS/100 sqm which calculates to 775 car parking requirement. However as per SDA, since the commercial and club facilities/community block are to be used by ONLY residents of the colony, exclusive parking for these ameneties has not been considered.Car baysize of 2.75x5.00m has been adopted as per NBC 2016.
3. SDA MP 2035 mentions 15% of organised green area. Organized open space for hilly areas in URDPFI guidelines mentions Housing area park requirement of 0.5 to 1 Ha for5000 population as per which approx.12 % of open space may fit the norms which SDA may explore.
NOTE : GAP OF 1.2M IS PROVIDED ALONG THE BOUNDARY WALL . CAR BAY SIZE : 2.75 X5
PROJECT :
PROPOSED VERTICAL HOUSING COLONYSHEHJAR APARTMENTS AT BEMINA , SRINAGAR , J & K
LEGENDS
EXISTING 2BHK AND 3BHK TOWER
PROPOSED 2BHK TOWER
PROPOSED 3BHK TOWER
TOTAL PLOT AREA 1.
EXISTING 2BHK TOWERS (S+7) 2.
EXISTING 3BHK TOWERS (S+7) 3.
PROPOSED 2BHK TOWER(S+12)option 1 (5.2.2021)
PROPOSED 3BHK TOWER (S+12)option 1 (5.2.2021)
6. TOTAL NO. OF TOWERS (EXISTING AND PROPOSED) TOTAL NO. OFF DUs.
7. FAR including towers & amenities area (Excluding STAIRCASE USED AS FIRE ESCAPE)
8. ORGANIZED OPEN SPACE OF SITE AREA) 9. PARKING REQUIRED
NOTE :
1. Provision of fire escape staircase and lift shall be finalized in consultation with services consultant.
2. (*) indicates that Parking has been calculated on the basis of FAR 1.47 (excluding fire escape and amenities area ).As per Srinagar MP 2035, parking is to be provided @1ECS/100 sqm .As per SDA, since the commercial and club facilities/community block are to be used by ONLY residents of the colony, exclusive parking for these amenities has not been considered.Car bay size of 2.75x5.00m has been adopted as per NBC 2016.
PROJECT :
PROPOSED VERTICAL HOUSING COLONYSHEHJAR APARTMENTS AT BEMINA , SRINAGAR , J & K
2BHK TOWER TYPICAL FLOOR PLAN
Note-
1.The core area and staircases (numbers, type, positioning, pressurization) in Two BHK and Three BHK towers shall be ascertained by service consultant from view point of fire safety norms.
2.The structural grid at the unit level and tower level shall be subject to the structural requirements as indicated by the structural consultant. The inputs with respect to stilt parking, unit /tower design shall be incorporated accordingly.
3.Internal staircase may require to be Pressurized in accordance to fire safety norms. Continuous pressurization mechanism will add to dwelling unit cost and operational cost for residents.
BLOCK AREA=439.66 SQM
BLOCK AREA=421.30 SQM (EXCLUDING UTILITY BALCONY)
DU'S TYPE-I UNIT AREA=84.14 SQM DU'S TYPE-II UNIT AREA=84.14 SQM
PROJECT :
DRAWING TITLE : AMENDMENTS
CLIENT : PROPOSED VERTICAL HOUSING COLONYSHEHJAR APARTMENTS AT BEMINA , SRINAGAR , J & K
SRINAGAR DEVELOPMENT AUTHORITY, J & K
GENERAL NOTES:
· FOR SIZE AND SPEC. OF STRUCTURE COMPONENT THE CONTRACTOR MAY REFER GOOD FOR CONSTRUCTION STRUCTURAL DRAWING.
· THE ARCHITECTURE DRAWING MAY BE READ IN CONJUNCTION WITH STRUCTURE DRAWINGS,IF FOUND ANY DEVIATION ,THE CONTRACTOR MAY SEEK CLARIFICATION FROM ARCHITECT.
· ALL DIMENSIONS ARE IN MILLIMETERS (MM) UNLESS OTHERWISE SPECIFIED.
· ALL LEVELS ARE IN MILLIMETERS(MM) UNLESS OTHERWISE SPECIFIED.
· RAILING,PARAPET AND STEPS AS PER DETAILS.
· WRITTEN DIMENSION ARE TO BE FOLLOWED.
PROJECT : CLIENT :
DRAWING TITLE : AMENDMENTS
PROPOSED VERTICAL HOUSING COLONYSHEHJAR APARTMENTS AT BEMINA , SRINAGAR , J & K
SRINAGAR DEVELOPMENT AUTHORITY, J & K
KITCHEN DETAIL2 BHK TOWER
ARCHITECTS: hudco
DESIGN AND DEVELOPMENT WING HOUSING & URBAN DEVELOPMENT CORPORATION HUDCO BHAWAN, I.H.C., LODHI ROAD, NEW DELHI-110003
NOTES:
·FOR SIZE AND SPEC. OF STRUCTURE COMPONENT THE CONTRACTOR MAY REFER GOOD FOR CONSTRUCTION STRUCTURAL DRAWING.
·THE ARCHITECTURE DRAWING MAY BE READ IN CONJUNCTION WITH STRUCTURE DRAWINGS,IF FOUND ANY DEVIATION ,THE CONTRACTOR MAY SEEK CLARIFICATION FROM ARCHITECT.
·ALL DIMENSIONS ARE IN MILLIMETERS (MM) UNLESS OTHERWISE SPECIFIED.
·ALL LEVELS ARE IN MILLIMETERS(MM) UNLESS OTHERWISE SPECIFIED.
·WRITTEN DIMENSION ARE TO BE FOLLOWED.
TOILET FIXTURE LAYOUT PLAN (TYPE-I)
PROPOSED VERTICAL HOUSING COLONYSHEHJAR APARTMENTS AT BEMINA , SRINAGAR , J & K PROJECT : CLIENT
3BHK TOWER TYPICAL FLOOR PLAN
Note-
1.The core area and staircases (numbers, type, positioning, pressurization) in Two BHK and Three BHK towers shall be ascertained by service consultant from view point of fire safety norms.
2.The structural grid at the unit level and tower level shall be subject to the structural requirements as indicated by the structural consultant. The inputs with respect to stilt parking, unit /tower design shall be incorporated accordingly.
3.Internal staircase may require to be Pressurized in accordance to fire safety norms. Continuous pressurization mechanism will add to dwelling unit cost and operational cost for residents.
DU TYPE-I
BLOCK AREA=542.64 SQM
BLOCK AREA=519.15 SQM (EXCLUDING UTILITY BALCONY) DU'S TYPE-I UNIT AREA=109.38 SQM DU'S TYPE-II UNIT AREA=109.53 SQM
DU TYPE-II
PROJECT :
DRAWING TITLE : AMENDMENTS
CLIENT : PROPOSED VERTICAL HOUSING COLONYSHEHJAR APARTMENTS AT BEMINA , SRINAGAR , J & K
SRINAGAR DEVELOPMENT AUTHORITY, J & K
GENERAL NOTES:
· FOR SIZE AND SPEC. OF STRUCTURE COMPONENT THE CONTRACTOR MAY REFER GOOD FOR CONSTRUCTION STRUCTURAL DRAWING.
· THE ARCHITECTURE DRAWING MAY BE READ IN CONJUNCTION WITH STRUCTURE DRAWINGS,IF FOUND ANY DEVIATION ,THE CONTRACTOR MAY SEEK CLARIFICATION FROM ARCHITECT.
· ALL DIMENSIONS ARE IN MILLIMETERS (MM) UNLESS OTHERWISE SPECIFIED.
· ALL LEVELS ARE IN MILLIMETERS(MM) UNLESS OTHERWISE SPECIFIED.
· RAILING,PARAPET AND STEPS AS PER DETAILS.
· WRITTEN DIMENSION ARE TO BE FOLLOWED.
PROJECT : CLIENT :
DRAWING TITLE : AMENDMENTS
SCALE: SRINAGAR DEVELOPMENT AUTHORITY, J & K DATE : KITCHEN DETAIL3 BHK TOWER
NOT TO SCALE
ARCHITECTS: hudco
DESIGN AND DEVELOPMENT WING HOUSING & URBAN DEVELOPMENT CORPORATION HUDCO BHAWAN, I.H.C., LODHI ROAD, NEW DELHI-110003 PROPOSED VERTICAL HOUSING COLONYSHEHJAR APARTMENTS AT BEMINA , SRINAGAR , J & K
NOTES:
·FOR SIZE AND SPEC. OF STRUCTURE COMPONENT THE CONTRACTOR MAY REFER GOOD FOR CONSTRUCTION STRUCTURAL DRAWING.
·THE ARCHITECTURE DRAWING MAY BE READ IN CONJUNCTION WITH STRUCTURE DRAWINGS,IF FOUND ANY DEVIATION ,THE CONTRACTOR MAY SEEK CLARIFICATION FROM ARCHITECT.
·ALL DIMENSIONS ARE IN MILLIMETERS (MM) UNLESS OTHERWISE SPECIFIED.
·ALL LEVELS ARE IN MILLIMETERS(MM) UNLESS OTHERWISE SPECIFIED.
·WRITTEN DIMENSION ARE TO BE FOLLOWED.
TOILET FIXTURE LAYOUT
TOILET FLOORING PLAN
PROPOSED VERTICAL HOUSING COLONYSHEHJAR APARTMENTS AT BEMINA , SRINAGAR , J & K
SCALE: SRINAGAR DEVELOPMENT AUTHORITY, J & K DATE : TOILET
DESIGN AND DEVELOPMENT WING HOUSING & URBAN DEVELOPMENT CORPORATION HUDCO BHAWAN, I.H.C., LODHI ROAD, NEW DELHI-110003
NOTES:
·FOR SIZE AND SPEC. OF STRUCTURE COMPONENT THE CONTRACTOR MAY REFER GOOD FOR CONSTRUCTION STRUCTURAL DRAWING.
·THE ARCHITECTURE DRAWING MAY BE READ IN CONJUNCTION WITH STRUCTURE DRAWINGS,IF FOUND ANY DEVIATION ,THE CONTRACTOR MAY SEEK CLARIFICATION FROM ARCHITECT.
·ALL DIMENSIONS ARE IN MILLIMETERS (MM) UNLESS OTHERWISE SPECIFIED.
·ALL LEVELS ARE IN MILLIMETERS(MM) UNLESS OTHERWISE SPECIFIED.
·WRITTEN DIMENSION ARE TO BE FOLLOWED.
Shower head/ as specs. Mirror above basin/ as specs.
Hot&Cold tap/ as specs. Wash-basin/ as specs. Water-closet/ as specs.
Ledge Wall/ 1200mm High
PROPOSED VERTICAL HOUSING COLONYSHEHJAR APARTMENTS AT BEMINA , SRINAGAR , J & K PROJECT : CLIENT
DEVELOPMENT
TOILET TYPE-B (3BHK)
STILT FLOOR PLAN
LAWN SIDE
1.THE MODIFICATIONS SHOWN BY HUDCO IN THESE DRAWINGS ARE PURELY FROM AESTHETICS/FUNCTIONAL POINT OF VIEW.
2.THE STRUCTURAL /SERVICE CONSULTANT MAY EXAMINE THESE MODIFICATIONS AND IF FOUND FEASIBLE,THE DRAWINGS MAY BE REVISED ACCORDINGLY WITHOUT COMPROMISING THE STRUCTURAL STABILITY,NORMS AND FEASIBILITY OF SERVICES.
3.THE ARCHITECTURAL DRAWING SHOWS TENTATIVE LOCATION OF THE PLUMBING FIXTURES . THE SERVICE CONSULTANT MAY EXAMINE THE LOCATION OF THESE FIXTURES AND IF REQUIRED MODIFY THE FIXTURES LOCATION FOR THE THE FEASIBLE STRUCTURAL SOLUTION.
4.ANY CHANGE IN THE LOCATION OF PLUMBING AND ELECTRICAL FIXTURE BY THE SERVICE CONSULTANT MAY BE BROUGHT TO NOTICE OF ARCHITECT BEFORE FINALIZING THE KITCHEN AND TOILET LAYOUT.
5 .THE SERVICE CONSULTANT MAY SHOW THE ELECTRICAL FIXTURES ACCORDING TO KITCHEN AND TOILET LAYOUT SEND BY HUDCO.
GENERAL NOTES:
· FOR SIZE AND SPEC. OF STRUCTURE COMPONENT THE CONTRACTOR MAY REFER GOOD FOR CONSTRUCTION STRUCTURAL DRAWING.
· THE ARCHITECTURE DRAWING MAY BE READ IN CONJUNCTION WITH STRUCTURE DRAWINGS,IF FOUND ANY DEVIATION ,THE CONTRACTOR MAY SEEK CLARIFICATION FROM ARCHITECT.
· ALL DIMENSIONS ARE IN MILLIMETERS (MM) UNLESS OTHERWISE SPECIFIED.
· ALL LEVELS ARE IN MILLIMETERS(MM) UNLESS OTHERWISE SPECIFIED.
· RAILING,PARAPET AND STEPS AS PER DETAILS.
· WRITTEN DIMENSION ARE TO BE FOLLOWED.
PROJECT : CLIENT :
DRAWING TITLE : AMENDMENTS
PROPOSED VERTICAL HOUSING COLONYSHEHJAR APARTMENTS AT BEMINA , SRINAGAR , J & K
SRINAGAR DEVELOPMENT AUTHORITY, J & K
KITCHEN DETAIL3 BHK TOWER
DATE
KITCHEN TYPE-A
Tentative
KITCHEN TYPE-A (Section R3-R3')
Tentative location of Geyser
KITCHEN TYPE-A (Section R2-R2')
1.THE MODIFICATIONS SHOWN BY HUDCO IN THESE DRAWINGS ARE PURELY FROM AESTHETICS/FUNCTIONAL POINT OF VIEW.
2.THE STRUCTURAL /SERVICE CONSULTANT MAY EXAMINE THESE MODIFICATIONS AND IF FOUND FEASIBLE,THE DRAWINGS MAY BE REVISED ACCORDINGLY WITHOUT COMPROMISING THE STRUCTURAL STABILITY,NORMS AND FEASIBILITY OF SERVICES.
3.THE ARCHITECTURAL DRAWING SHOWS TENTATIVE LOCATION OF THE PLUMBING FIXTURES . THE SERVICE CONSULTANT MAY EXAMINE THE LOCATION OF THESE FIXTURES AND IF REQUIRED MODIFY THE FIXTURES LOCATION FOR THE THE FEASIBLE STRUCTURAL SOLUTION.
4.ANY CHANGE IN THE LOCATION OF PLUMBING AND ELECTRICAL FIXTURE BY THE SERVICE CONSULTANT MAY BE BROUGHT TO NOTICE OF ARCHITECT BEFORE FINALIZING THE KITCHEN AND TOILET LAYOUT.
5 .THE SERVICE CONSULTANT MAY SHOW THE ELECTRICAL FIXTURES ACCORDING TO KITCHEN AND TOILET LAYOUT SEND BY HUDCO.
GENERAL NOTES:
· FOR SIZE AND SPEC. OF STRUCTURE COMPONENT THE CONTRACTOR MAY REFER GOOD FOR CONSTRUCTION STRUCTURAL DRAWING.
· THE ARCHITECTURE DRAWING MAY BE READ IN CONJUNCTION WITH STRUCTURE DRAWINGS,IF FOUND ANY DEVIATION ,THE CONTRACTOR MAY SEEK CLARIFICATION FROM ARCHITECT.
· ALL DIMENSIONS ARE IN MILLIMETERS (MM) UNLESS OTHERWISE SPECIFIED.
· ALL LEVELS ARE IN MILLIMETERS(MM) UNLESS OTHERWISE SPECIFIED.
· RAILING,PARAPET AND STEPS AS PER DETAILS.
· WRITTEN DIMENSION ARE TO BE FOLLOWED.
PROJECT : CLIENT :
DRAWING TITLE : AMENDMENTS
PROPOSED VERTICAL HOUSING COLONYSHEHJAR APARTMENTS AT BEMINA , SRINAGAR , J & K
SRINAGAR DEVELOPMENT AUTHORITY, J & K
KITCHEN DETAIL3 BHK TOWER
SCALE:
ARCHITECTS: hudco
1.THE MODIFICATIONS SHOWN BY HUDCO IN THESE DRAWINGS ARE PURELY FROM AESTHETICS/FUNCTIONAL POINT OF VIEW.
2.THE STRUCTURAL /SERVICE CONSULTANT MAY EXAMINE THESE MODIFICATIONS AND IF FOUND FEASIBLE,THE DRAWINGS MAY BE REVISED ACCORDINGLY WITHOUT COMPROMISING THE STRUCTURAL STABILITY,NORMS AND FEASIBILITY OF SERVICES.
3.THE ARCHITECTURAL DRAWING SHOWS TENTATIVE LOCATION OF THE PLUMBING FIXTURES . THE SERVICE CONSULTANT MAY EXAMINE THE LOCATION OF THESE FIXTURES AND IF REQUIRED MODIFY THE FIXTURES LOCATION FOR THE THE FEASIBLE STRUCTURAL SOLUTION.
4.ANY CHANGE IN THE LOCATION OF PLUMBING AND ELECTRICAL FIXTURE BY THE SERVICE CONSULTANT MAY BE BROUGHT TO NOTICE OF ARCHITECT BEFORE FINALIZING THE KITCHEN AND TOILET LAYOUT.
5 .THE SERVICE CONSULTANT MAY SHOW THE ELECTRICAL FIXTURES ACCORDING TO KITCHEN AND TOILET LAYOUT SEND BY HUDCO.
GENERAL NOTES:
· FOR SIZE AND SPEC. OF STRUCTURE COMPONENT THE CONTRACTOR MAY REFER GOOD FOR CONSTRUCTION STRUCTURAL DRAWING.
· THE ARCHITECTURE DRAWING MAY BE READ IN CONJUNCTION WITH STRUCTURE DRAWINGS,IF FOUND ANY DEVIATION ,THE CONTRACTOR MAY SEEK CLARIFICATION FROM ARCHITECT.
· ALL DIMENSIONS ARE IN MILLIMETERS (MM) UNLESS OTHERWISE SPECIFIED.
· ALL LEVELS ARE IN MILLIMETERS(MM) UNLESS OTHERWISE SPECIFIED.
· RAILING,PARAPET AND STEPS AS PER DETAILS.
· WRITTEN DIMENSION ARE TO BE FOLLOWED.
PROJECT : CLIENT :
DRAWING TITLE : AMENDMENTS
PROPOSED VERTICAL HOUSING COLONYSHEHJAR APARTMENTS AT BEMINA , SRINAGAR , J & K
SRINAGAR DEVELOPMENT AUTHORITY, J & K
KITCHEN DETAIL3 BHK TOWER
DATE
ARCHITECTS: hudco
SPECIAL NOTES
1.THE MODIFICATIONS SHOWN BY HUDCO IN THESE DRAWINGS ARE PURELY FROM AESTHETICS/FUNCTIONAL POINT OF VIEW.
2.THE STRUCTURAL /SERVICE CONSULTANT MAY EXAMINE THESE MODIFICATIONS AND IF FOUND FEASIBLE,THE DRAWINGS MAY BE REVISED ACCORDINGLY WITHOUT COMPROMISING THE STRUCTURAL STABILITY,NORMS AND FEASIBILITY OF SERVICES.
3.THE ARCHITECTURAL DRAWING SHOWS TENTATIVE LOCATION OF THE PLUMBING FIXTURES . THE SERVICE CONSULTANT MAY EXAMINE THE LOCATION OF THESE FIXTURES AND IF REQUIRED MODIFY THE FIXTURES LOCATION FOR THE THE FEASIBLE STRUCTURAL SOLUTION.
4.ANY CHANGE IN THE LOCATION OF PLUMBING AND ELECTRICAL FIXTURE BY THE SERVICE CONSULTANT MAY BE BROUGHT TO NOTICE OF ARCHITECT BEFORE FINALIZING THE KITCHEN AND TOILET LAYOUT.
5 .THE SERVICE CONSULTANT MAY SHOW THE ELECTRICAL FIXTURES ACCORDING TO KITCHEN AND TOILET LAYOUT SEND BY HUDCO.
GENERAL NOTES:
· FOR SIZE AND SPEC. OF STRUCTURE COMPONENT THE CONTRACTOR MAY REFER GOOD FOR CONSTRUCTION STRUCTURAL DRAWING.
· THE ARCHITECTURE DRAWING MAY BE READ IN CONJUNCTION WITH STRUCTURE DRAWINGS,IF FOUND ANY DEVIATION ,THE CONTRACTOR MAY SEEK CLARIFICATION FROM ARCHITECT.
· ALL DIMENSIONS ARE IN MILLIMETERS (MM) UNLESS OTHERWISE SPECIFIED.
· ALL LEVELS ARE IN MILLIMETERS(MM) UNLESS OTHERWISE SPECIFIED.
· RAILING,PARAPET AND STEPS AS PER DETAILS.
· WRITTEN DIMENSION ARE TO BE FOLLOWED.
PROJECT : CLIENT :
DRAWING TITLE : AMENDMENTS
PROPOSED VERTICAL HOUSING COLONYSHEHJAR APARTMENTS AT BEMINA , SRINAGAR , J & K
SRINAGAR DEVELOPMENT AUTHORITY, J & K
KITCHEN DETAIL3 BHK TOWER
SCALE:
STILT FLOOR PLAN
· ALL DIMENSIONS ARE IN MILLIMETERS (MM) UNLESS OTHERWISE SPECIFIED.
· ALL LEVELS ARE IN MILLIMETERS(MM) UNLESS OTHERWISE SPECIFIED.
· RAILING,PARAPET AND STEPS AS PER DETAILS.
· WRITTEN DIMENSION ARE TO BE FOLLOWED.DRAWING IS NOT ON SCALE.
1ST FLOOR PLAN
SECTION-E1E1'
· FOR SIZE & SPECS. OF STRUCTURAL COMPONENT THE
MAY REFER "GOOD FOR
"STRUCTURAL DRAWING. · THE STRUCTURAL DRAWING MAYBE READ IN CONJUNCTION WITH ARCHITECTURE DRAWING,IF FOUND ANY DEVIATION,THE CONTRACTOR MAY SEEK CLARIFICATION FROM ARCHITECT. · ALL DIMENSIONS ARE IN MILLIMETERS (mm) UNLESS OTHERWISE SPECIFIED.
· ALL LEVELS ARE IN MILLIMETERS (mm) UNLESS OTHERWISE SPECIFIED.
· RAILING, PARAPET & STEPS AS PER DETAILS.
NOTE : SIZES AND POSITIONS OF ALL COLUMNS ARE TENTATIVE.SAME SHALL BE FINALIZED WITH CONSULTATION FROM STRUCTURAL CONSULTANT.